Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2015-0050
78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEARTN MAY 11 2015 BUILDING PERMIT COMMUNICITY10FLAQN DEA RADAPA TMENT Ga r�,t� C) VOICE (760) 777-7125 FAX (750) 777-7011 ECTIONS (760) 777-7153 Application Number: BSOL2015-0050 Owner: Property Address: 45010 DESERT VIEW CT GEORGE ESCOBEDO APN: 604331030 45010 DESERT VIEW DOURT Application Description: ESCOBEDO / (35)ROOF MOUNTED SOLAR PANELS (2) INVERTERS 9.1KW LA QUINTA, CA 92253 Property Zoning: LIC. No.: 888104 Application Valuation: $30,000.00 Applicant: Contractor: SOLARCITY CORPORATION SOLARCITY CORPORATION 3055 CLEARVIEW WAY 3055 CLEARVIEW WAY ATTN ZOE STEELE ATTN ZOE STEELE SAN MATEO, CA 94402 SAN MATEO, CA 94402 (650)963-5630 LIC. No.: 888104 LICENSED CONTRACTOR'S DECLARATION . I hereby affirm under penalty of perjury that I am lic nsed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 the usiness and Professions Code, and my License is in full force and elle License (��Class: ijC4 B. C1/0 A Lice se No.: 8104 Date:4-, l i 1,( Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( 11, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Date: 5/11/2015 . WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier:— Polity Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I s 'u becom subject to the workers' compensation provisions of Se .0 f the Labor od , I shall forthwith comply wit tho a provisions. Dater Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVfRAPE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AN C IL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and s to ws r Ing to building construction, and hereby authorize representative f thi it to en r u on the above. mentioneV property for inspection purposes. Date: ItSignature (Applicant or Agent . FINANCIAL .• l• DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $2.00 $2.00 5/11/15 PAID BY METHOD . RECEIPT # CHECK # CLTD BY SOLARCITY CORPORATION CHECK R5980 220870 MFA Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $2.00 $2.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $24.17 5/11/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SOLARCITY CORPORATION CHECK R5980 220870 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $24.17 5/11/15 PAID BY METHOD RECEIPT # CHECK # 'CLTD BY SOLARCITY CORPORATION CHECK R5980 220870 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV•SYSTEM - MISC EQUIPMENT 101-0000-42403 0 $24.17 $24.17 5/11/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SOLARCITY CORPORATION CHECK R5980 220870 MFA DESCRIPTION. ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - MISC EQUIPMENT PC 101-0000-42600 0 $24.17 $24.17 5/11/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SOLARCITY CORPORATION CHECK R5980 220870 MFA Total Paid for ELECTRICAL: $96.68 $96.68 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $91.85 5/11/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SOLARCITY CORPORATION CHECK R5980 220870 MFA Total Paid forPERM1T ISSUANCE: $91.85 $91.85 TOTALS:•0 •• Permit Details PERMIT NUMBER City of La Quinta BSOU20115 0050 Description: ESCOBEDO / (35)ROOF MOUNTED SOLAR PANELS (2) INVERTERS 9.1KW Type: SOLAR Subtype: Status: ISSUED Applied: 5/4/2015 SKH Approved: 5/11/2015 MFA Parcel No: 604331030 Site Address: 45010 DESERT VIEW CT LA QUINTA,CA 92253 Subdivision: TR 23935 Block: Lot: 25 Issued: 5/11/2015 MFA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $30,000.00 Occupancy Type: Construction Type: Expired: 11/7/2015 MFA No. Buildings: 0 No. Stories: 0 No. Unites: 0 NOTIFIED MELANIE W/ SOLAR CITY THAT PLANS WERE Details: 9.1kW SOLAR ARRAY - (35) 260W KYOCERA KU2606XPA PANELS (2) ABB PVI-3.6-OUTD-S-US-Z-A INVERTER [560SF] 2013 CALIFORNIA ELECTRICAL CODE. JAKE FUSON 5/11/2015 ADDITIONAL SITES __j.Applied Applied to Approved j Approved to Issued FINANCIAL INFORMATION Printed: Monday, May 11, 2015 12:23:32 PM 1 of 3 V? srs•rcrts CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE • NOTES NOTIFIED MELANIE W/ SOLAR CITY THAT PLANS WERE E-MAIL JAKE FUSON 5/11/2015 5/11/2015 APPROVED AND PERMIT WAS READY TO ISSUE. CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE -ZIP PHONE FAX EMAIL APPLICANT SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 ( DOURT FINANCIAL INFORMATION Printed: Monday, May 11, 2015 12:23:32 PM 1 of 3 V? srs•rcrts INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED DATE DATE RESULT REMARKS NOTES SOLAR FINAL** BLD CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $2.00 $2.00 5/11/15 RS980 220870 CHECK S RORAATTION MFA CORRPP Total Paid for BUILDING STANDARDS ADMINISTRATION $2.00 $2.00 BSA: PV SYSTEM -ARRAY, 101-0000-42403 0 $24.17 $24.17 5/11/15 R5980 220870 CHECK SOLARCITY MFA FIRST 20 CORPORATION PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $24.17 5/11/15 R5980 •220870 CHECK SOLARCITY MFA FIRST 20 PC CORPORATION PV SYSTEM - MISC 101-0000-42403 0 $24.17 $24.17 5/11/15 R5980 220870 CHECK SOLARCITY MFA, EQUIPMENT CORPORATION PV SYSTEM - MISC 101-0000-42600 0 $24.17 $24.17 5/11/15 R5980 220870 CHECK SOLARCITY MFA EQUIPMENT PC CORPORATYTION ORA Total Paid forELECTRICAL: $96.68 $96.68 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $91.85 5/11/15 R5980 220870 CHECK SOLARCITY MFA CORPORATION Total Paid for PERMIT ISSUANCE: $91.85 $91.85 TOTALS:•0 •0 .53 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED DATE DATE RESULT REMARKS NOTES SOLAR FINAL** BLD Printed: Monday, May 11, 2015 12:23:32 PM 2 of 3 SYSTElNS Printed: Monday, May 11, 2015 12:23:32 PM 3 of 3 CBFWSYSTEMS Bin # Cray Of 4 QUii1td Bullding 8t Safety Division P.O. Box 1504,78-495 Calle Tampico La.Quinta, CA 92253 -:(760) 777-7012 Building Permit Application and Tracking Sheet Pemlit # Project Address. O WTA Owner's Name:. �O A er.MIDA CA A2253Address: o q, S V t C/ V V Legal Description: City, ST, zip: La Quin'ta, CA n5 Contractor. Solar City Tel PrcjectDescription:� roof mounted solar panels . Address: 3055 Clearview Way. city, Sr, zip: San Mateo, CA, 94402 2 inverters Telephone: 650-638-1028 Swee Lia # : 888104 City Lie #, Arch., Engr., Designer: Address: City., ST. Zip: Telephone: State Lia #: 61Project Name of Contact Person: Melanie Plasse Construction Type: , Occupancy: type (circle one): New Add'n Alter Repair Demo Sq. Ft: #Stories: #Units: Telephone # of Contact Person: Estimated Value of Project APPLICANT: DO NOT WRITE BELOW THIS UNE # Sobmittal Req'd Recd TRACENG PERMIT FEES Plan sets Plan Cheek submitted Item Amount Structual Calces Reviewed, ready for e9aw ions ISS V e / Plan Check Deposit. . Tlruw Calcs. Called Contact Person 5 /� Plan Check Balance. Title 24 Calcs. Plans picked up Construction "Flood plain plan Plans resubmitted' Mechanical Grading plan 2" Review, ready for correctionsfissue Electrical Sobeorimctor List Called Contact Person Plumbing Grant Deed Plans #[eked up S.M.L H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''" Review, ready for correetionsAssue Developer Impact Fee Planning Approval. Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees PJ1k ON A0101 Ig 1% N,6pft APR 012015 -- CITY 2015..CITY OF LAQUINTA COMMUNITY DEVELOPMENT tii-ErY I OVEI 'lsTf;U'" TRANSFORMER INFORMATION: KVA PHASE HIGH KV LOW 120/240V —METER#AD184-2616 "PROPOSED BI—DIRECTIONAL METER#------------- CUTLER—HAMMER # DG322URB — AC DISCONNECT: 2 FT FROM MAIN PANEL — INVERTER: ABB (2) PVI -3.6 200A, 240V, SINGLE PHASE, 2 WIRES, 22kAiC EXISTING BI DIRECTIONAL METER# AD184-2616 JA� EPT. '- CD 0 0 CD Cn (' (E) DRIVEWAY C Front Of House AC R 4 — — 3' FSB __------ I - / I / 604331030 0 PITCH: 24 ARRAY PITCH: 24 MPl AZIMUTH: 289 ARRAY AZIMUTH: 289 MATERIAL: Low Profile W -Tile STORY: 1 Story PITCH: 24 ARRAY PITCH: 24 MP2 AZIMUTH: 109 ARRAY AZIMUTH: 109 MATERIAL: Low Profile W -Tile STORY: 1 Story PITCH: 28 ARRAY PITCH: 28 MP3 AZIMUTH: 19 ARRAY AZIMUTH: 19 MATERIAL: Low Profile W -Tile STORY: 1 Story ter. (E) UTILITY METER & WARNING LABEL m� INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS O DC JUNCTION/COMBINER BOX & LABELS DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS DEDICATED PV SYSTEM METER STANDOFF LOCATIONS C CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR -- GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED r, Ik 'I INTERIOR EQUIPMENT IS DASHED L ='J SITE PLAN 1E Scale: 3/32" = 1' 01' 10' 21' S li CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE NOR SH LL ANYONE EXCEPT IN WHOLE INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION NTH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARgTY INC. JOB NUMBER:rKLNX JB -9223119 0 0 Qentn: utxaarmm: ESCOBEDO, GEORGE ESCOBEDO RESIDENCE 45010 DESERT VIEW CT 9.1 KW PV ARRAY LA QUINTA CA 92253 PAGE NAME: 7607723835 SITE PLAN ULUbM Bryan Blanchard .,�;,,. . �•� "'.;;SolarCity MOUNTING SYSTEM: ZEP Mighty Hook A_xoo< MODULES: (35) KYOCERA # KU2606XPA 3055 gearview way Sm Moteo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY(765-2489)www.solarcity.com SHEET: REV: DATE: PV 2 4/11/2015 INVERTER: ABB # PVI-3.6—OUTD—S—US—Z—A ZEP SPANNER BAR I, DIA BOLT & NUT [EP SPANNER 7.1'AR CLAMP t �I?� STANDOFF J (E) TILE (E) ROOF DECKING (5) (4) 5/16" DIA STAINLESS STEEL LAG BOLT (2-1/2" EMBED, MIN) f��LOWEST MODULE SUBSEQUENT MODULES (E) RAFTER 1 STANDOFF S+ Scale: 11/2" = 1' INSTALLATION ORDER LOCATE RAFTER, MARK RAFTER LOCATION, AND REMOVE TILE. (1) PLACE STANDOFF BASE & DRILL PILOT HOLES AT THE RAFTER LOCATION. Q2) CLEAN PAPER AROUND PILOT HOLE. . Q ADJUST STANDOFF TO BATTEN HEIGHT. SEAL PILOT HOLES AND BOTTOM (4) OF STANDOFF WITH POLYURETHANE SEALANT. 5) LAG STANDOFF INTO RAFTER. q6) NOTCH TILE WEATHERING TO -FIT AROUND STANDOFF. 7) REINSTALL TILE. —( B SIDE VIEW OF MP2 NTS MP2 X -SPACING I X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" 48" 48" 24" 24" PORTRAIT 48" 20 TOP CHORD 2X4 @ 24" OC BOT CHORD 2x4 @24" OC ROOF AZI ARRAY AZI 109 PITCH 24 STORIES: 1 109 PITCH 24 Low Profile W -Tile A SIDE VIEW OF MPI NTS MPI X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" 48" 48" 24" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC BOT CHORD 2x4 @24" OC ROOF AZI ARRAY AZI 289 PITCH 24 289 PITCH 24 STORIES: 1 Low Profile W -Tile C SIDE VIEW OF MP3 NTS MP3 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" 48" 48" 24" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC BOT CHORD 2x4 @24" OC ROOF AZI ARRAY AZI 19 PITCH 28 STORIES: 1 19 PITCH 28 Low Profile W -Tile CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE ,�B NUMBER J B- 9 2 2 3119 0 0 PREMISE DWN� DESCRIPTION: ESCOBEDO, GEORGE ESCOBEDO RESIDENCE DESS Bryan Blanchard ``,?+. �;,,So�arCity. MOUNTING SISTER zEP Mighty Hook BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS 45010 DESERT VIEW CT 9.1 KW PV ARRAY LA QUINTA, CA 92253 �� _ i.; MODULES: EXCEPT IN CONNECTION WITH ' :' :' ORGANIZAl10N, THE SALE AND USE OF THE RESPECTIVE (35) KYOCERA # KU2606XPA PAGE NAME 3055 ClemNew Way Son Mateo, CA 94402 SHEET. REV. DATE INVERTER ABB # PVI-3.6—OUTD—S—US—Z—A SOLARCITY EQUIPMENT, WITHOUT THE WRIIIEN PERMISSION OF SOLARCITY INC. 7607723835 STRUCTURAL VIEWS PV 3 4/11/2015 T.(650) 638-1028 F:(650) 638-1029 (888)-SIL—CITY (765-2489) .w..soIar«ty.aon r UPLIFT CALCULATIONS _ 04.11.2015 Vetsfon #43.1 `�►��.#� PV :System Structural p # Sola�Cit 1, DeMan.! oftware Pro ea,InformAtion &T;40100f Contents DESIGN Bryan Blanchard Risk-t'Cagoryt Pskem Type MOUNTING SYSTEM ZEP Mighty Hook II MODULES: (35) KYOCERA # KU2606XPA 3055 CleaMew Way S3 5 Cie CA 94402 (888)-SSOL)aT�7r58-2489).:w�'a►yeom 5olarGty.,Slee ld lodnt INVERIR ABB PVI-3.6-OUTD-S-US-Z-A Spanish Tfle,Rbof .Spanish Tile, Roof' L erC m Ro6f'in �! Roof Slope Rafter S' aero 24"NOG PV System Module:Orientatibn' _ La t* and.Portrait: PV -'M d le,Area� 620" PV. Module. Width ;39" ml; Lengtti 65" Standoff AttadimentHardware Ml htv Hook HDG:ST Reduced Ground/.Roof LiWSnoinr Load's' Ground Snow Load:. pg. 0.0 psf. O:O.psf ASCE ,abfe�, AStf Eq:74„�1 Surrounding'RoefSnow RoofSnowBver.PVModules 0:0 ASCE.E' �74= Wind otsi in, tape i k . Wmd'Design Code' ASCE 7=10 WiRa.P0 Me!pd—,Portia Basic Wind:Speed pCategpry 1.6`-S e Mean Roof He g t- Effective:Wind.Arei -1 Module Fully E�neiosed Me. °ti'i �d �! 11g::2664A Section V 110 mph aC h Gabie Roof 15 fty r,g :30 ¢za)e/csn/a S 26.2 A. ::173 sf'l 1601509.3-A Wind.Ptdssi6+e"Cat&Uli3tio4�Co'fcients Wind Pressure Exposure 'K2. 0.85; Table 30.3;f p- ..- �.--.-.-._....-.. Topographic.Fador �.._ Kif i b0. — `Sedlon268� Wind.Diredionalit Factor Kd 0.85. Section 26 &,1__ Im o"" once; addV I- NA: Velocity Pressure qh AIN = 0.00256 (Kz);(Kzt) (Kd) (V^2) 22.4: '$f" Equatiop 30:3=1 Ext-Tressure beMdent (Up) iC-.,re—ss.f,_ a - dent' D-rni)— Ext:. Pressure Coeffldent, Dawn_ GCO:(Up) —..._.I 6 ..., G ;Down 0:95` Fi9::3o 4-2AJe/c-sale. r 0.88' r,�:,3o4-2A/BJf-SA/8 Desi n Wind Pressure` _ . h GC 1E' uation`30A4 Wind,Pressure�.Up Wind Pressure i)owri; down 19:H5, 3f Allowable SfandofHF S 4sin s X -Direction Y -Dire dbn Wbi Allowable'Standoff 5 con' R� 9^ Landsea' a 48" 48" Max Allovv_ale Carrtileve! Standoff..Confl uiation: U'6dsca a Not=Sta ge ed' Max Standoff Tributary A'fea Trio _ 16'sf=" PV Asse , b66 Lead .�� NetWin_d_Uplif"atStandoff= Uplift Gapadty of Standoff; ,13v. _ T_adual 3 psf: _178'Ibs T=allow. 350 Itis' Standoff Demand Ca a .DCR. 51.0% Mail Allowable Standoff Sj5jdhd Pbth4lf48" 48" SMA -110 wiable� C� Ie"ve, = ._P.grhalt_ 20 24= Siandofif nfl uration Portrait Nof7Sta6 gered Max1 ributary Asea PV Assembly Dead Load Trio W PV 16sfy 3 pif jr-*..� . r ---.— Net 1Mnd Upliff.at_Standoff Uplift Capadty of'Standoff T act. l 178165 T -allow 350 Ibs, Standoff<Demand :Ca a DG 51.0%. CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZA710N, IXCEPT IN CONNECTION WITH ORGAPARTNIZATION, THE SALE AND USE OF THE RESPECTIVE PERMI�oNEOF SD�arJiNOC..T THE WRITTEN JOB NUMBER: JB -9223119 0 0 PREMISE OWNER: DESCRIPTION: ESCOBEDO, GEORGE ESCOBEDO RESIDENCE 45010 DESERT VIEW CT 9.1 KW PV ARRAY LA QUINTA CA 92253 s PAGE NAME 7607723835 UPLIFT CALCULATIONS DESIGN Bryan Blanchard N�k ■ QN't, ��d Olar ity �r MOUNTING SYSTEM ZEP Mighty Hook ;..":, MODULES: (35) KYOCERA # KU2606XPA 3055 CleaMew Way S3 5 Cie CA 94402 (888)-SSOL)aT�7r58-2489).:w�'a►yeom SHEET: REV. DATE PV 4 4/11/2015 INVERIR ABB PVI-3.6-OUTD-S-US-Z-A 'GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE OND (N) #8 GEC TO (E) LIFER AT PANEL Panel Number: Inv 1: DC Ungrounded INV 1 -(')ABB' PVI-3.6-OUTD-S-US-Z-A LAPEL A -(35)KYOCERA # KU2606XPA CA # 888104 WITH IRREVERSIBLE CRIMP Meter Number: AD184-2616 Inv 2: DC Ungrounded FCI Inverter, Zlgbee 3600W, 24OV, 9 PV Module; 260W, 232.9W PTC, 40MM, Blk Frame, H4, ZEP, 1000V, w/Ba kbar C-10 Underground Service Entrance INV 2 —( )ABB I PM-3.6—WTD—S—US—Z—A LABEL B FCI Inverter, Zigbee 360OW, 24OV, 967o Voc: 38,3 Vpmax: 31 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 125A MAIN SERVICE PANEL E 10OA/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! SolarCity CUTLER -HAMMER BRYANT N 125A Load Center Inverter 1 IND Vstart = 120V 100A/2P Disconnect 11 9 ABB A DC- PVI-3.6-OUTD-S-US-Z-A oc- MP 1: 1x8 (E) LOADS B �• C 20A/2P Li �40D--------- —----------- -------- - -E - - - - - - - - - - - - - ----j • L2 DC+ 40A/2P GND N DG I _EGG DCr $ 2 DC+ Vstart = 120V _ _ _ _ — B — i Z r -- - - - - - - - - - - - — - - - - - - - - - - - GEC — T NGND MP 3� lx9- EGGc I E c -- --= — --------- ------------ _ — —F— — — —— ----_� — - - - - - ADJUST MIN. ACTIVATION VOLTAGES! (1)Conduit Kit; 3/4" EMT N Inverter 2 IND EGC/GEC — z z I I 10 ABB PVI-3.6-OUTD-S-US-Z-A 8 3 E DC+ Vstart = 120V DG MP 3: 1x10 U --— GEC —_� 1 20A/2P ; zaov L, �--------- ------------ -- - - - - -- -- E�------------ - ----j L2 DC+ TO 120/240V i SINGLE PHASE I UTILITY SERVICE I j L — --_----_________-____------- N DG I EGG T r-::: DC+ —GEC ---T� DG 7 4 oc+ Vstart = 120V DG MP 2: 1x8 I I I GND -- Ems--- --------- ------------ - -�----- - -E - ------ ----------� I (I )Conduit Kit; 3/4' EMT - CITY OF LA QUINT PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED BUILDING & SAFETY DEPT. AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, APPROVED ^ ^ p o� / C D Hr P f i V G TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF FOR CONSTRUCTION GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. DATA r PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE Voc* =MAX VOC AT MIN TEMP INSTALLED ONLY BY QUALIFIED PERSONS POIT (1) CUTLER—RAMI $ BQC 30240 PV BACKFEED BREAKER Breaker, 30A P—aOAJ 2 Spaces, Quadplex R (1) CUTLER—HAMMER $ DG222URB Disconnect; 60A, 24OVoc, Non—Fusible, NEMA 3R AC A (1) SolarCitY 4 STRING JUNCTION BOX 2x2 SAAGS, UNFUSED, GROUNDED DC — (1)Ground Rod; 5/8' x 8', Copper — (1) CUTLER— AMMER DG100NB GroundX.utrol A 60-100A General Duty (DG) C (1) BLoYANTadd R120/24OV, CAter,r�1L25A NEMA 3R — (2)Breaker. 0A%2P, 2 Spaces 1 AWG 18, THWN-2, Block ©� (1)AWG J8, THWN-2, Red �� 1 AWG $10, THAN -2, Block O 14r (1)AWG $10, THWN-2, Red 1)AWG 110, THWN-2, Black Voc* = 388.13 VDC O (1)AWG 110, THWN-2, Red Vmp = 279 VDC U Isc = 9.09 ADC Imp= 8.39 ADC 2) AWG 110, PV WIRE, Black Voc* = 345.01 VDC Isc = 9.09 ADC 1 "' iO (1)AWG $10, Solid Bare Copper EGC Vmp = 248 VDC Imp= 8.39 ADC (')AWG 18, THWN-2, White NEUTRAL Vmp =240 VAC Imp=32 AAC - (' )AWG �,. TF1WN-2,. Green • , EGC/GEC.- 0 ).Conduit, Kit;, 3/4' ,EMT, , , • , , , , , , (1)AWG $10, THWN-2, White ,, , , , , , —.0 AWG #8,, TH,WN-2,, Preen , , (1 AWG $10, THWN-2, Block NEUTRAL,Vmp =240 VAC Imp=16 AAC EGC/GEC ,— 0 Conduit, Kit;. 3/4',ENT, , , , ... _ (1 AY,G 1'0, THWN72,,Green, EGC ..... .............................. (1)AWG 110, THWN-2, Black Voc* = 345.01 VDC 6 O (I)AWG 110, THWN-2, Red Vmp = 248 VDC Isc = 9.09 ADC Imp= 8.39 ADC Z O L� (2 )AWG 110, PV WIRE Black Voc* = 388.13 VDC Isc = 9.09 ADC (1) AWG 110, Solid Bare Capper EGC Vmp = 279 VDC Imp= 8.39 ADC ®� (1)AWG $10, THWN-2, Red (1)AWG $10, THWN-2, White 7.0 )AAG $8,. TFPNTI-2,. Green ..EGC/GEC,- NEUTRAL Vmp =240 VAC Imp=16 AAC (1)Conduit. Kit;. 3/47.EMT.... . � . (1 AWG 110, 1HWN72, . Green EGC .................. (1)AWG 110, 1HWN-2, Black Voc* = 345.01 VDC (I)RE (1)AWG 110, THWN-2, Red Vmp = 248 VDC Isc = 9.09 ADC Imp= 8.39 ADC L J �� ....... (2 ) AWG $10, PV W1AE Black Voc* = 431.26 VDC Isc = 9.09 ADC O (1) AWG 110, Solid Bare Copper EGC Vmp = 310 VDC Imp= 8.39 ADC 01 AWG 110, 1HWN-2..Green.. FGC .................. (1)AWG 110, THWN-2, Black W/OC* = 431.26 VDC ®� (1) AWG 110, THWN-2, Red Vmp = 310 VDC Isc = 9.09 ADC Imp= 8.39 ADC ®� .. ... . (2) AWG 110, PV WIRE, Black VDC* = 345.01 VDC ISc = 9.09 ADC (1) AWG $10, Solid Bare Copper EGC Vmp = 248 VDC Imp= 8.39 ADC ���LLL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARGTY INC., JOB NUMBER J B- 9223119 0 0 PREMISE OWNER: DESCRIPTION: ESCOBEDO, GEORGE ESCOBEDO RESIDENCE DESIGN:CONFIDENTIAL Bryan Blanchard �+ ��� ���SolarCity. MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN OTHERS THE RECIPIENTS ZEP Mighty Hook . 45010 DESERT VIEW CT 9.1 KW PV ARRAY LA CA 92253 MODULES: ORGANIZATION, C PT IN IZ ORGANIZATION, EXP;EPT IN CONNECTION WITH QUINTA, _ THE SALE AND USE OF THE RESPECTIVE (35) KYOCERA # KU2606XPA 3055 aearview way s30 Mateo, CA 94402 SHEET: REV. DATE PERMISSIONSOLARCITY EOFISOLARCITY IWT,IHE WRITTEN PAGE NAME 7607723835 THREE LINE DIAGRAM PV 5 4/11/2015 (888) (SOL,CITY ((765-248 638-1028 9)�w w.solarcity.com INVERTER ABB PVI-3.6—OUTD—S—US—Z—A ` ELECTRICAL CALCULATIONS ME String and 2 Combined Strings Module Type: Module Count: Icont =(Amps): Kyocera 260 1000V 17 11.36 Branch Circuit _.Individual MPPT -_ -- -- _ --= --- - - I strings per Branch A 1 -strings per Branch B - - 10 modules per series string 8 modules per series string Inverter Output Inverter Type: Inverter Count: ABB PVI -3.6-S AFCI 1 ABB PVI -3.6-5 AFCI 1 String Branch A Branch B Q ■ 1&% �;; olarCity. Conductor: Conductor: Conductor: (cont' 1.25 = (Amps) 14.2 14.2 14.2 30 deg C ampacity = 40 40 40 PV Wire Size: AWG #10 AWG #10 AWG #10 Icont = (Amps) 11.36 11.36 11.36 Start ampacity 40 40 40 Temperature derate (%=F) 0.41 0.41 0.41 Conduit fill derate (%_#) 1 0.8 0.8 Derated ampacity 16.4 13.12 13.12 (cont' 1.25 = (Amps) 14.2 14.2 14.2 Ampacity 40 40 40 Inverter Output Inverter Type: Inverter Count: ABB PVI -3.6-S AFCI 1 ABB PVI -3.6-5 AFCI 1 Total (cont = (Amps): 32 I CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: J B- 9 2 2 3119 O O (cont' 1.25 = (Amps) 40 Q ■ 1&% �;; olarCity. MOUNTING SYSTEM: ZEP Mighty Hook OCP Size = 40 3 3055 gewiew Woy s0 Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (668)—SOL—CITY (765-2489) www.solarcity.com SHEET: REV. DATE: PV 6 4/11/2015 Conductor 3: AWG #8 THWN-2 (cont " 1.25 = (Amps) 40 30 deg C ampacity = 55 Icont = (Amps) 32 Start ampacity 55 Temperature derate (%=F) 0.91 Conduit fill derate (%_#) 1 Derated ampacity 50.05 Icont' 1.25 = (Amps) 40 Amoacity 50 Total (cont = (Amps): 32 I CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: J B- 9 2 2 3119 O O n mbt umuc Mkxruun: ESCOBEDO, GEORGE ESCOBEDO RESIDENCE 45010 DESERT VIEW CT 9.1 KW PV ARRAY LA QUINTA CA 92253 PAGE NAME 7607723835 ELECTRICAL CALCULATIONS ura�n: Bryan Blanchard Q ■ 1&% �;; olarCity. MOUNTING SYSTEM: ZEP Mighty Hook A. MODULES: (35) KYOCERA # KU26O6XPA 3 3055 gewiew Woy s0 Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (668)—SOL—CITY (765-2489) www.solarcity.com SHEET: REV. DATE: PV 6 4/11/2015 INVERTER: ABB # PVI-3.6—OUTD—S—US—Z—A Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (INV) Per Code: CEC 690.5(C) Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE -------.9y-1f-- (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR "� `.��3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED -0 San Mateo, CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, LabelSet T:(650) 638-1028 F:(650) 638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE O.(888}501-Cm(765-2489) www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. iarCivj ''SolarCity ZepSolar .Zep System for concrete the roofs Next -Level PV Mounting Technology Q,'SolarCity Components ZepSolar 1x 3x 4x Spanner Bar Part Nos. 850-1400 - 4x 850-1399 - 3x 850-1398 -1x Next -Level PV Mounting Technology (Spanner Ctampl A � _.��li� lop djustablc Mighty Hook � r „� [Array skm Splice Kit Spanner Clamp n - -� Part No. 850-1401 Listed to UL 2703 Part No. 850-1194 Listed to UL 2703 G ntert A Y11%':1 m l 0104T/ SFA � 0y� Description r PV mounting solution for concrete tile roofs CdMppt� Works with all Zep Compatible Modules • Auto bonding UL -listed hardware creates structual and electrical bond • Zep System has a UL 1703 Class "A" Fire Rating when installed using V� LISTED modules from any manufacturer certified as "Type 1" or "Type 2" Adjustable Mighty Hook Interlock Cam Foot 1W Part No. 850-1396 Part No. 850-1388 Part No. 850-1413 011111111111— Listed to UL 2582 Listed to UL 2703 Listed to UL 2703 Specifications Designed for pitched roofs Installs in portrait and landscape orientations 2= • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 Engineered for spans up to 72" and cantilevers up to 24" Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt, Grip, End Caps DC Wire Clip Attachment method UL listed to UL 2582 for Wind Driven Rain Part No. 850-1172 Part Nos. 500-0113, Part No. 850-1448 Listed to UL 2703 and 850-1421, 850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solars products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solars products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. This document does not create any express warranty by Zap Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solars products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 01 13 15 ZS for Concrete Tile Roofs Cutsheet Rev 02.pdf Page: 1 of 2 01 13 15 ZS for Concrete Tile Roofs Cutsheet Rev 02.pdf Page: 2 of 2 This family of single-phase string The high-speed MPPT offers real- Highlights: inverters complements the typical time power tracking and improved — Single phase and split phase output number of rooftop solar panels energy harvesting. grid connection. enabling home -owners to get the most The flat efficiency curve ensures high — Wide input range for increased efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. of the property. a consistent and stable performance — The high speed and precise MPPT across the entire input voltage and algorithm offers real time power This inverter offers a dual input output power range. tracking and improved energy . section that processes two strings The transformerless operation gives the harvesting. with independent Multiple Power Point highest efficiency of up to 97.0%. — Outdoor NEMA 4X rated enclosure Tracking (MPPT). The wide input voltage range makes for unrestricted use under any This is especially useful for rooftop the inverter suitable to low power environmental conditions. installations with two different installations with reduced string size. — Integrated DC disconnect switch orientations from two sub -arrays This rugged outdoor inverter has been in compliance with international oriented in different directions. (For designed to be a completely sealed Standards (-S Version). example: East and West) unit able to withstand the harshest The dual input sections with environmental conditions. independent MPPT enable a more optimal energy harvesting condition. Power and productivity n NOR for a better world— F%111" Additional highlights: — RS -485 communication interface (for connection to laptop or data logger). — Integrated Arc Fault Detection and Interruption (-A Version). Technical data and types ao 2 ABB Solar Inverters I Product Byer for M-3.0/3.6/3.8/4.2-TL-OUTD 19 KyOCERa CUTTING EDGE TECHNOLOGY As a pioneer with four decades of experience in the development of photovoltaic systems, Kyocera drives the market as a leading provider of PV products. We demonstrate our Kaizen philosophy, or commitment to continuous improvement, by setting the industry standard in the innovation of best -in -class solar energy equipment. QUALITY BUILT IN • UV -stabilized, anodized aluminum frame in black • Supported by major mounting structure manufacturers • Easily accessible grounding points on all four corners for fast installation • Proven junction box technology with 12 AWG PV wire works with transformerless inverters •Amphenol H4-UTX locking plug-in connectors provide safe, quick connections PROVEN RELIABILITY • Kyocera modules confirmed by the Desert Knowledge Australia Solar Centre to have the highest average output of any crystalline module • First module manufacturer in the world to pass long- term sequential testing performed by TUV Rheinland • Only module manufacturer to achieve the rank of "Performance Leader" in all six categories of GTM Research's 2014 PV Module Reliability Scorecard CERTIFICATIONS • UL1703 Certified and Registered, UL Module Fire Performance: Type 2, CEC • NEC 2008 Compliant, IEC 6121561730, and ISO 14001 SGOMPq Te C USCOMpN" KU -60 1 OOOV Z Series KU255-6XPA KU260-6XPA KU -60 1000V Series ELECTRICAL SPECIFICATIONS MODULE CHARACTERISTICS Standard _ o do Cells per module: 60 (6 x 10) Dimensions: 65.43in i38.98ini 1.57in KU 255 -6XPA K • length/Wfdth/height (1662mmi990mmi40mm) Weight 47.4lbs (21.5kg) Fin_ 255 260 W vmP 30.8 31.0 v PACKAGING SPECIFICATIONS ImP 8.28 8.39 A Modules per pallet 20 V� 38.0 38.3 V Pallets per 53' container. 36 Pallet box dimensions: 66ini40ini43in I 8.83 9.09 A 1ength/t4ddth/height (1675mmi1005mni1055" Pty° +5/-0 +5/-0 % Palletboxweight 1060lbs(480kg) Nominal Operating Cell Temperature Conditions• NOCT=800WIN12irrodionce, - , 1.57- • 4.33' TN� 45 45 °C I I 111 P 1 83 1 87 W JUNCTIONm.. - OOA�5)VmP 27.7 27.9CABLE W/ mBCONNECTOR (_�jPOTTED (+� 6.61 6.71 A LABEL STABILIZER BAR V_ 34.8 35.1 V lu 7.15 7.36 A PTC - `- 228.3 232.9 W FTernperatUre Coefficients STABILIZER BAR �?nax -0.45 -0.45 %/°C I t.tD czr> Vmp -0.48 -0.48 %/°C / r ImP 0.02 0.02 %J°C 38.98"(9901 ;/ l V� -0.36 -0.36 %/°C 0.06 0.06 %/°Co (D Operating Temp -40 to +90 -40 to +90 °C Grounding Hole Slotted Mounting Hole 0.16- (4m) 0.35-x0.47- (9mm 12.4 Systen) Design FRAME CROSS SECTION DIAGRAM Series Fuse Rating 15 A a' Maximum DC System Voltage (UL) 1000 V >N Hailstone Impact in (25mm) @ 51 mp (23m/s) a 1.>a-tssw 1. ss-ua„t 'Subject to simulator measurement uncertainty of +1- 3%. KYOCERA reserves the right to modify these specifications without notice. LONG/SNORT SIDE STABILIZER BAR NEC 2008 COMPLIANT WARNING: Read the insbuclion UL 1703 LISTED handling. in its entirety prior 10 handling. installing & operal- 062614 ing Kyocera Solar modules. OUR VALUED PARTNER of c e AI .2B1 551 DM. WIANIIIY 1 KNOCKOUTS FOR 1-1/2 CONWD NOTE: I. METC OIMENSDNS w MWMErM ARE SXOwN W KEfS. 2. IC RANGE OF WGS G 1/0-014 COPPER OR XUMNUM. E •}• .} }s�"'.�'rm��°'<wma Poc w LVILtN—MAMMtN .._� d'Of'$� ems. i mWSu m aG ^. pXFN90X SXEEi I � I e0 AMP mE 3R OENERIL DUIY - "95-1451 is 1 m vw. 8 7 6 5 4 3 2 1 ID I IA J 0... Zep Solar ZS Tile - for the roofs ZS Tile'" offers the fastest and least expensive way to install PV arrays on tile roofs. It's designed to interoperate with a growing list of Zep Compatible PV modules that incorporate the patented Zep Groove frame specification. Utilizing quarter -turn, rock -in, and drop-in con- nections, ZS the eliminates the need for rails and separate grounding hardware while offering a superior aesthetic approach. Key System Benefits Dramatically reduces installation time Key Technical Features Low system weight Easily enables additional support Eliminated mounting rails and clip at array edges for high wind hardware applications Eliminates separate grounding Interlock ETL listed to UL 1703 as hardware ground bond means Rapid, top -accessible precision array leveling Ultra -reliable hyper -bonded grounding matrix Ultra-low parts count Enhanced aesthetics Ground Zep UL and ETL listed to UL 467 as grounding and bonding device Interlock, Leveling Foot, and Ground Zep listed to UL 2703 as PV bonding device Datasheet: ZS Tile Zep Compatible" ZS Tile mounting hardware is designed for use with Zep Compatible`" PV modules from leading PV module Manufacturers. Visit zepsolar.com for a current list of Zep Compatible'" PV modules. Our Other Product Families v`aNPgr/e� IOW UL LISTED eaNPP� Page 1 of 2 Datasheet: ZS Tile Components Interlock � v The Interlock provides north -south and east -west structural and ground bond connections creating a structurally contiguous hyper -bonded array. Interlock UL listed to UL 2703 and E-rL listed to UL 1703. Leveling Foot133.8mm] (30.7mm] A- 1--t m] 1.25in 1.21 in (39.4mm] l 2.25in 1.55in (61.2in L �- 3.20in L � (IOl.dmm] a.noin The Leveling Foot provides a means of attachment between the PV array and the mounting surface or flashed attachment apparatus and allows for easy array height adjustment (1.25- throw). Array Skirt J n:Y 1m The Array skirt facilitates easy front -row installation while providing a clean look at the front of the PV array. Ground Zep rr AMA The Ground Zep provides a point of connection between the PVarray and the equipment grounding conductor. One Ground Zep is required for every 72 PV modules. UL and ETL listed to UL 467. UL listed to UL 2703. Universal Box Bracket The Universal Box Bracket allows rapid attachment of electrical boxes to the module frame. Array Skirt Cap Set The Array Skirt Cap Set provides an aesthetic cover for the exposed end of the Array Skirt. Made of anodized aluminum, each set comeswith two Skirt Caps. AC/DC Cable Clip Clips into Zep Groove for ultra -fast and easy management of PV wiring and micro -inverter cables. Tools Zep Tool:4 functions, I tool; Flat Tool: For inter -module removal. 111, document does not 0,11 at, no. wdnenty M lest Suit, an abaci it, products ar semcos leo Salary m11 "armnry is contained in the mitten in dou--only lm each product. the eckay, documentation shippedxith lap splalt products aaMilates the sale spedneallons(elated to In the Product Wnanty. The QldorM is solely responsible for mibing the suitability of lep5olars products la each use Specification are subject to damage without mike Copyright 02010-1017lap Solas Inc US Patent 91591531 US Patent 8,109,04&IAS 81nfl Patents Pending, Last Update: February 25.7013 3.11 Per Replacement Tile The Replacement Tile provides a means of flashed attachment for ZS Tile installations. Visit repiolar.eam for more information abaci our products and company. Page 2 of 2 ZS Aero for low -slope & flat roofs .ZS Comp' for composition shingle roofs .ZS Seam - For standing seam metal roofs .ZS Span - for rail -based applications .ZS Trap' for trapezoidal metal roofs .ZS Wave - for corrugated roofs v`aNPgr/e� IOW UL LISTED eaNPP� Page 1 of 2 Datasheet: ZS Tile Components Interlock � v The Interlock provides north -south and east -west structural and ground bond connections creating a structurally contiguous hyper -bonded array. Interlock UL listed to UL 2703 and E-rL listed to UL 1703. Leveling Foot133.8mm] (30.7mm] A- 1--t m] 1.25in 1.21 in (39.4mm] l 2.25in 1.55in (61.2in L �- 3.20in L � (IOl.dmm] a.noin The Leveling Foot provides a means of attachment between the PV array and the mounting surface or flashed attachment apparatus and allows for easy array height adjustment (1.25- throw). Array Skirt J n:Y 1m The Array skirt facilitates easy front -row installation while providing a clean look at the front of the PV array. Ground Zep rr AMA The Ground Zep provides a point of connection between the PVarray and the equipment grounding conductor. One Ground Zep is required for every 72 PV modules. UL and ETL listed to UL 467. UL listed to UL 2703. Universal Box Bracket The Universal Box Bracket allows rapid attachment of electrical boxes to the module frame. Array Skirt Cap Set The Array Skirt Cap Set provides an aesthetic cover for the exposed end of the Array Skirt. Made of anodized aluminum, each set comeswith two Skirt Caps. AC/DC Cable Clip Clips into Zep Groove for ultra -fast and easy management of PV wiring and micro -inverter cables. Tools Zep Tool:4 functions, I tool; Flat Tool: For inter -module removal. 111, document does not 0,11 at, no. wdnenty M lest Suit, an abaci it, products ar semcos leo Salary m11 "armnry is contained in the mitten in dou--only lm each product. the eckay, documentation shippedxith lap splalt products aaMilates the sale spedneallons(elated to In the Product Wnanty. The QldorM is solely responsible for mibing the suitability of lep5olars products la each use Specification are subject to damage without mike Copyright 02010-1017lap Solas Inc US Patent 91591531 US Patent 8,109,04&IAS 81nfl Patents Pending, Last Update: February 25.7013 3.11 Per Replacement Tile The Replacement Tile provides a means of flashed attachment for ZS Tile installations. Visit repiolar.eam for more information abaci our products and company. Page 2 of 2 SolarCity Standard Box 4J The SolarCity Standard Box 4J is a • Manufactured to meet UL 1741 Standards. 4 -String unfused Junction Box. The box . Non -Metallic, Corrosion Resistant NEMA 4X Enclosure. is highly configurable and adaptable using the (4) jumper blocks included in • Factory -Installed Cordgrip Enhances Installation Speed. each box. A factory installed cordgrip • Break-Thru Skinned -Over Glands on Cordgrip Provide enhances installer productivity. Weathertight Seal for All Configurations. • Easily Configurable Terminal Blocks Permit Adaptation to Site -Specific Stringing Needs. ��� SolarCityo October 2013 Technical Data / Specifications ©A Voltage Rating [VDC] : 600V © Maximum DC Current [A]: 57A © Maximum Continuous Current [A]: 42A ©D Maximum Voltage [VDC]: 600V ©E Wire Size Range [AWG]: #6 to #14 Enclosure Rating: NEMA 4X © Operating Temperature Range [°C]: -40 to 50 O Typical Overall Dimensions [in]: 8"x6"x4"