BRES2015-023478-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
Property Address:
APN:
Application Description
Property Zoning:
Application Valuation:
Applicant:
'KENIOHNSON
41515 CREST DRIVE
LA QUINTA, CA 92253
DRES2015-0234
52450 AVENIDA DIAZ
773252011
LOAYZA RESIDENCE - FIRE
Titit 4 , iarw VOICE (760) 777-7125
FAX (760) 777-7011
COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 8/25/2015
Owner:
ALFREDO LOAYZA
.52450 AVENIDA DIAZ
)A� REPAIR LA QUINTA, CA 92253
2015 � 1
ASG ti 4
C�UEUINo�RjMENS
tgov
coo
LICENSED CONTRACTOR'S DECLARATION .
1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C-9 B C35 License No.: 0936
ate:/ G �_ Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the j
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
I ) 1, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(� I am exempt under Sec.. B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for whish this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's
Contractor:
DESERT DRYWALL CONSTRUCTION
P 0 BOX 10580
INDIO, CA 92202
(760)391-9700
Llc. No.: 910936
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
✓ I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with thoserovisions.
/
Date: Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above•
mentioned propertffoorrin(s�pection purposes.
Date: -"��gnature(Applicant-or Agent):My
L/
4
t
.�`4'S`' .+r�`�,y<.�'^� tt, # s^J
` e.Y :DESCRIPTION€F c«�, 1 ��,k� x QT=Y�: « PAID 1 PAID DATE:
y;:,,3;i'�7-�FsYe?::"z,'',is>'L"=C.3Px-i,.4:,"a'<W4,xh;a.., �%->Ra}€ti✓tM'!x
_.A000UNT x eFAIVIOUNT
».4,xi>'•"w`'-.,>:..:..dxdk:..<'e4ii-...:F,:.,.:.tkb`s£,`-<.�.�z+a'i4'iY cz•>4".,c.ea't 3::'; "�'�+u �:< ;.:s':�i�:9 Earo.;sT .
HOURLY PLAN CHECK -YES, 101-0000-42600 1'.
. I $70.00
$0.00
.Yyn.r.•SITie;g- .r�'<:yam,n.:�ri.:iS<i,""�o:�'Ki',X,"i:?.
'i Avt'< y% :+£ zxry -✓ S f b * `�: Ar')'
a �
� #METHOD*�RECEIP.,T
X
#� 2
f .+i^ei` }..< '.�'?En
r # CLTD BY,
4 W
a1:10
_.k :,T .. _.Y S,:ax.v"K..,.CL.' x:. n. 4e,h+, ws,fr'S.:1 r.. E.•.3v',:.3-'.,. a,-,....a': 7,sC!.;,4 urw4..
, z
x y CHECK r:
!
Total Paid for BLDG CITY STAFF-- PER HOUR: $70.00 $0.00
;"�$' RIM," r'a,i. ;'m�
�x DESCRIPTION
-.,`t �. rT>�
;' ACCOUNT
QTY
ma
AMOUNT
'� �'wu'F• y
PAID ��
r,.
x.
DATE
h�
;_.,.�:� HMO
,.s�>
��,';4�_�,: £,����<a�k�r���
x�x� �
t� ��.PAID
BSAS SB1473 FEE
:101-0000-20306
0
$4.00
$0.00
"r'. z .�•F. ¢" .:. r.
i.,,,£`.PAID. BYL''�.
E} F =:�' ` `A ,`, .L .
�,,<,METHOD
<, £"k
�
y¢ 4. , a.»,w:t'.;� x'3i `k `�
RECEIPTS#�
. E :"z,E bi 3? 'L`f
CHECK #F.-
.k'u 'x::Yt41
'CLTD BY
.r&ss '�,..?,. i3! : :.t. !�..4.�a. ' .�...>'d 'Rt•=eTi`.-
�'-� �,��,,;,
?.:.r..,ai�. 7.°'A :.?zMN:<xi4:>s; ..x .:.... :x-X.
<
„�
...r.'u a,Ak .:. ^:. �r�[, x.x r^.: _r�,,,,� r
E>.
.M, Yfi;.<:.,'�
Total Paid forBUILDING STANDARDS ADMINISTRATION BSA '$4.00 $0.00 ,
NMI . -s 3 >'': °k ..i�c,?r.c''y f a s.as .26v
'£"'S' =3' h n..wp:;tlu' .L{'H,XY ;•i.£ "tdf�.<e" �,v'FFp" "'a<".:
f"ry �•.m';.gxy�E"b
xAMOUNT.
SY. A: ,41 :.
P..
�v���'DESCRIP.,TION��21n3§AiCCOUNT�s
Wi?s?.fvxri•ai`w+,r>N'?<N,h:(,...:i,<.,i.::"4MY{'.".:'xv$`'s'x„i5C/+,o»?xh.y,.:iR.,F;:;'?Gh.:°??:3':`V?rir.:+;^:
sz-r?L'w.':G'bn�.: i�i.W.<i:h':-Ef.:Y?ivw
Ef'�?b<a9tr#rt+�„t9£:;
;.=ePAID 4)F*;1
}z;•:£i. :i :t::',i"i..e'r`sr�`t<
1PAIDDATE.
...EW�.,�;.; •.:'•G. :^
DEVICES, FIRST 20.
101-0000-42403
0 •' $24.17
• $0.00
qt;'.'" g. - AQ; .. kM.. j z x.- -*�a..
+
:i{< $ "'' -`t`' zw;.Ch: i..s' "^`.r,...
w
@• 3 :3l:7<s'y..,t'`c..' ^'C"3 r�*A .. T4
#
3'.V°CHECK•# X
CLTD BY;
pPAIDiBY
C.:,x...'icxr��-'�'<:>^M'.'i: 3%' h5£x If '�:�r:Y'.'�'_<x5G_.f�.n�.:.art,'i+<�';A➢..<iN_".f�i:.:.H.�3.
�METHOp
d.
: °;RECEIP:T
.�.Y659£#:..P:y?.:?:ro.:
e..r lrvo.Y�•.va1�iY
'�'.44 R.r\::,�.<
:f
DESCRIPTION
a?'.�i,�y<
� ACCOUNT
",AMOUNT
� PAID; �
-.
PAIU;pATE
S
v� E y f
yTY
b, ry
F� y �
DEVICES, FIRST 2ii0 PC
101-0000-42600 "
• 0
$24.17
$0.00
ef".F.'$gi::..y
.x<"'Y
ffSf"�c,-.'?vJ:•s41 �:i3i'�Ld
S '�:;"`ffi'a
t�;'v 4t�{ :9'n";✓va :y :ai'fsij
8•qq
#
f.L ,
yro+ { "'6Tfr
CHECK #
;s.:.,r
CLTD BY
4r; x.'.a
METHOD'
,RECEIPT
4:£.g"i$.G�''`�S,
n •,,
}
Rrz, 774w - d
Total Paid for ELECTRICAL: $48.34 $0.00
. qs 4'iz.+. ''u
t
"5'r£i �£ -1' ax -T-VT
��
QTY
.'£..
DATE
DESCRIPTION ,
;ACCO UNT
yEAMOUNTtPAID
APPLIANCE REPAIR/ALTERATION
101-0000-42402
0
$12.09
$0:00•
.x �Mi
< PAID BY'
it
"
xRECEIPT #�
CIiECK�#E
CLTD BY €�.
.I��;4�,�v�yaMETHOD
�, ,«: >wyy ::,.4 ., i....: Teti
.,...... : x .£h:, «w:, _..«..:
Q^TiC' s4eY 5.':?..G:.£ Ya
.. f ... ...k,:n ,"{ -e
E yr. <r::i<Y
::: sp. .�h,%� :.&% 4< ..'
.,,C x '-
.......<
W x<? �s.
b
<. k.. .... <. a
.
a
�.
T
0� tUNT-,
?P.brA,:I_DeK
£,
DATE.
'
i.s�
�RA
'a's�,-
rygd
APPLIANCE REPAIR/ALTERATION PC
101=0000-42600.
0
.$41.83
$0.00
�,�n-?" rrc ,aY a . a ....:�,E�
RECEIPET?#.'
m..' <•.:' :r`... :. •i �
CHECK #
x . S-.
BY
F'=.iPAID.BY x, `<�°ib2FMETHOD.,
��
�.�T rCLTD
.a
F3
Total Paid for MECHANICAL: $16.92 $0.00 `
,d?ka-001,1" ±�
YX .dt ...:.. �S;n' �-. -E! s. � .:
DESCRIPTION
yy
F'z <°�":.. _. x6x�y'�e".ux4� ..✓yy�� - ,�
ACCOUNT
..,�'ryt..;y
ry
I... g! _ <. T�..<a"s �. � ffi3�
AMOUNT
f. .'r"SYk ��y{:�...!' L=X, � N.
PAID'i14 �`
F
y U. ,
A
j,PAID?DATE
WATER HEATER/VENT
101=0000-42401
0.•
$12.09
$0.00
GF x 2-ro`r yts `•ii-i,£«tj�yt
'._' ...N �3 "' _:<k`^'`uSi:.":6 yy''rh�ya
Q ;i
RECEIPTS#
�_. `S
#
CLTD€.BY:
�3'
N , EiCHECK
z
:rv�Q 4rS,.k<1' h< i ^d ri�d;w^^"J.'k'...i,•S rh "h'a<<M-;�"';:. 'i.tE'.E, _-A£ J f ..F1 :.yk?
i', .. $e'TNd'S2f'x•'vnl`,, N:m l.r.�E
�A000UNT. . i >4
Y$<w ;t.$?`ET :.T,..kls T`<4.; l,k rF
=AMOUN x:$,�xk
F✓ '. X Y l..rE:
�PAIDj` `s'
�
.
PAID"3DATE
;zt'S5��!:OESCRIPTION?«�E."
:S' 3.'C__.. '0eii3:uk£:s. ' s+,� ""5. ":".L><.%i,<,s::`?�.iC z `i'v<2 k4 a•�'W .. w. �'
s k
�L'4 ' :v''we:n a '.i9i:F.+' _J:, .�'�+v sikw z.
p�QTYr€
4, %N fii
nS:EAF.' •di,v .FO �:x, tZF>
'Yti,S.y '4 C Y
WATER HEATER/VENT PC,
101.0000=42600
:•0
$7.25
$0.00
s PAID BY x
INIETHOD
`:RECEIP,T #Kati«
a ?� 'CHECK
CLTD BYj
,< s r p.
x.'�.="a_a'✓;,-•.k.1..iYs"�...°S::}..,k
yj X„iw�'',p�YF..:
'g DESCRIPTION
ACCOUNTQTYAINIOUNT
ri.
P.A10 E
b
a•,::tP;k;`.s.``:�„ar
r'�.Z'..-r,:9"s..<,te. 3'�eKL ,5
�Pi41D°DATE..
�k`:-i51;4 >•e..
WATER SYSTEM INST/ALT/REP.
101=0000-42401
0'
$12:09
$0.00
b � �` . � �M r. �. rad : , , --. , _;' -. :,fir« �``�
tl g -!, >b �Z'tc" ; ��' "6,G k "+'i Y
BY
; .. .. ;,, r4 ,w' r�
* . 'q' a I k "�
� �&;
i:zx aa«
x _. �..: � ; a
'F� k-
RECEIPTfr#
#
BY
: sokME,,PAID �;
,j X
��
n9CI1ECK _.,; ,
CLTD r
4
t
MESC
t �-C ugg' - NH
0 U NT,
qvff.
PAI
DESCRIPTION
g
MvIUUNTA,,"KVW
D�
ID.DATE,
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$1 2.09
$0.00
-�;'PAIUB 4, I WE
gm g".Im,
1
THUM
�.!KECEIPT.Afmaxi
-4-
;!�!'CL D,BY
T
'v— kK
2
Total, Paid for PLUMBING FEES: $43.52 $0.00
N'
DESCRIPTIONCOUNT`
MAM 2, A
m6UNT
�'VPAID'DATE-
REMODEL, EA ADDITIONAL 500 SF
0
$43.50
$6.00
!O� ga
t -'�W-
V
�KECEIPX.,#, 'Q
NOME
R
BY
DSCRIPTIONE-R
�A'CCOUN
AMOUNT rA, 9
In�
�'P
PAID DATE"
n' NEW
�!T H �IR
an -4NT-
f -Ttx
441 U
t Z':
in
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42600-
$34.80
$0.00
H
�"
PAIDrBYREVUE
-METH ID
R
V m,414'
T `11:14- kc,
'g
Nag
DATE:`
"tA.
REMODEL, FIRST 100 SF
101-0000-42400
0
0
$49.31
$0.00
0 PAID. BYAMIM, pi
g
:RECEIPT
-g
m
w
R
I rl'-AU
A
�NiP
A
7q
i4^0-'-"�'DESCRIPTION�,d,,��,*,q!-,;-fl'!-",,vi RE,
ur'
, K I T
0.1� BRIE,
Mi
QT
AMOUNTIT,
4 A I D
A ATE�
.'er iX
g
NOV mz�
,
mij K
H-mm-M.N I V
REMODEL, FIRST 500SFPC
101-0000-426010,
0
$134.88
$0.00
NO 0R`PAID'BY�;`K�=.
KKK5
0f,.'RERECEIPT#
V; i 0
V
Total Paid forREMODEL: .$261.49. $0.00 -
-'Vg�g
ii'.,-�',,,.�DESCRIPTION -�H�:ti 31M 1 Rm
m n�
04
g I'M
0 N'tH ',O'N
OR,
AW"MUMV
mty
gk
i"I' A MOUNTE
MO .—"v-.'
PAID
'bATE'
41i,
, I
L, ' <3PAID
SMI - RESIDENTIAL
101-0000-20368'..
0
$13.00
$0.06
'k IV
R',
4!UML ETHOD
•HK
'4
XHECK:M-�x
4
U41vM4 5B". MWR 10 -MI,
I mVNIR
Total forSTRONG MOTION' INSTRUMENTATION SMI: $13.00 $0.00'
�'p
'Iq kil
ININ
I �10
,DOOR/WINDOW, REPLACE FIRST 7,
.,101TO00042400,
0
.$60.91
$9.00,
rr"W"Af
DD R-
RECEIPT
T
13
lax
DESCRIPTION
1 22 �4 AN
�MOLINT
-K'PAID
DATE,
y a
41 0
-10
POOR/WINIDOW, REPLACE, FIRST 7 PC-
101-0000426001
0
$110.22
$0.00
Vt'��MRU� 1-2,iv
N
METHOD"
MIN 41
-'(�tILTWB
11H
J�6
Total Paid forWINDOW/S,LID,ING GLASS, DOOR/FENESTRATIQN: $171.13. $0.00
lig 1101
MESC
Description: LOAYZA RESIDENCE - FIRE DAMAGE REPAIR
ADDITIONALSITES
Type: BUILDING, RESIDENTIAL Subtype: REMODEL
Status: APPROVED
Applied: 6/12/2015 AZA
Approved: 8/12/2015 JJO
Parcel No: 773252011 Site Address: 52450 AVENIDA DIAZ LA QUINTA,CA 92253
Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 9
Lot: 12
Issued:
UNIT 1
NOTES
Lot Sq Ft: 0 Building Sq Ft: 0
Zoning:
Finaled:
Valuation: $100,000.00 Occupancy Type:
Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0
No. Unites: 0
IS READY FOR ISSUE OWNER WOULD LIKE TO BE CONTACTED.
Details: WORK STARTED PRIOR TO PERMIT ISSUANCE. RED TAGGED 6/23/2015.
Printed: Tuesday, August 25, 2015 12:11:19 PM 1 of 4
CrMYSTEMS
ADDITIONALSITES
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE COMPLETION DATE
NOTES
PLEASE CALL APPLICANT FOR CORRECTIONS. WHEN PERMIT
NOTE
JIM JOHNSON
6/29/2015
6/29/2015
IS READY FOR ISSUE OWNER WOULD LIKE TO BE CONTACTED.
SK
PLAN CHECK COMMENTS
FROM CONSULTANT
KAY HENSEL
8/14/2015
8/14/2015
STRUC APPROVABLE 8/13/2015
RECEIVED
PLAN CHECK PICKED UP
ED VASQUEZ
6/30/2015
6/30/2015
PICKED UP BY ARCHITRC PER ED. PJ
2nd N/S PLAN CHECK, BUT 1ST ROUND CORRECTIONS
PLAN CHECK SENT TO
KAY HENSEL
7/24/2015
7/24/2015
REQUIRE A STRUCTURAL P/C. SENT TO YOUND, DUE BACK
OUTSIDE.PC
8/7/2015.
PLAN CHECK SUBMITTAL
ED VASQUEZ
7/23/2015
7/23/2015
RECEIVED
Printed: Tuesday, August 25, 2015 12:11:19 PM 1 of 4
CrMYSTEMS
PUBLIC COUNTER VISIT
PHILIP JUAREZ
8/21/2015
•
8/21/2015
OWNER OF PROPERTY CAME IN AND I EXPLAINED TO HIM
ABOUT OWNER BUILDER INFORMATION HE THEN THOUGHT
ABOUT IT AND HE MIGHT JUST WANT CONTRACTOR TO PULL
PERMIT WITH A SUBLIST.
TELEPHONE CALL
JIM JOHNSON
6/29/2015
PAID DATE RECEIPT # CHECK # METHOD PAID BY
6/29/2015
CALLED OWNER ALFREDO LOAYZA TO INFORM HIM OF
CORRECTION
TELEPHONE CALL
JIM JOHNSON
8/12/2015
YES
8/12/2015
PHILIP TALKED TO THE OWNER, ALFREDO AND TOLD HIM
PLANS ARE READY TO ISSUE, THE CITY WILL NEED A
CONTRACTOR, TO ISSUE PERMITS
Total Paid for BLDG CITY STAFF - PER HOUR:
$70.00
$0.00
BSAS SB1473 FEE
1 101-0000-20306
1 0
$4.00
$0.00
Total Paid forBUILDING STANDARDS ADMINISTRATION
$4.00
PHONE FAX EMAIL
NAME TYPE NAME ADDRESS1
CONTACTS,
CITY
STATE
ZIP
APPLICANT
KEN JOHNSON 41515 CREST DRIVE
LA QUINTA
$0.00
CA
92253
(
Printed: Tuesday, August 25, 2015 12:11:19 PM 2 of 4
' - RSYSTEti15
•'
•
CLTD
DESCRIPTION ACCOUNT CITY
AMOUNT
PAID
PAID DATE RECEIPT # CHECK # METHOD PAID BY
BY
HOURLY PLAN CHECK - 101-0000-42600 1
$70.00
$0.00
YES
Total Paid for BLDG CITY STAFF - PER HOUR:
$70.00
$0.00
BSAS SB1473 FEE
1 101-0000-20306
1 0
$4.00
$0.00
Total Paid forBUILDING STANDARDS ADMINISTRATION
$4.00
$0.00
BSA:
DEVICES, FIRST 20
101-0000-42403
0
$24.17
$0.00
DEVICES, FIRST 20 PC
101-0000-42600
0
$24.17
$0.00
Total Paid forELECTRICALr
$48.34
$0.00
Printed: Tuesday, August 25, 2015 12:11:19 PM 2 of 4
' - RSYSTEti15
TDESCRIPTION
_ ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
_ PAID BYCLTD
-BY
BY
APPLIANCE
101.0000-42402
0
$12.09
$0.00
REPAIR/ALTERATION
APPLIANCE
REPAIR/ALTERATICIN PC
101-0000-42600
0
$4.83
$0.00
Total Paid forMECHANICAL: $16.92 $0.00
WATER HEATER/VENT
101-0000-42401
0
$12.09
$0.00
WATER HEATER/VENT
101-0000-42600
0
$7.25
$0.00
PC •
WATER SYSTEM
101-0000-42401
0
$12.09
$0.00
INST/ALT/REP
WATER SYSTEM
101-0000-42600
0
$12.09
$0.00
INST/ALT/REP PC
Total Paid forPLUMBING FEES: $43.52 $0.00
REMODEL, EA
101-0000-42400
0
$43.50
$0.00
ADDITIONAL 500 SF
REMODEL,
101-0000-42600
0
$34.80
$0.00
ADDITIONAL 5000 SF PC
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$0.00
REMODEL, FIRST 500 SF
101-0000-42600
0
$134.88
$0.00
PC
Total Paid for REMODEL: $262.49 $0.00
SMI - RESIDENTIAL
101-0000-20308
0
$13.00
$0.00
Total Paid forSTRONG MOTION INSTRUMENTATION SMt $13.00 $0.00
DOOR/WINDOW,
101-0000-42400
0
$60.91
$0.00
REPLACE FIRST 7
DOOR/WINDOW,
101-0000-42600
0
$110.22
$0.00
REPLACE, FIRST 7 PC
Total Paid for WINDOW/SLIDING GLASS
DOOR/FENESTRATION: $171.13 $0.00
Printed: Tuesday, August 25, 2015 12:11:19 PM 3 of 4
R?SYSTENIS
INSPECTIONS
SEQIDINSPECTION TYPE INSPECTOR SCHEDULED COMPLETED
DATE DATE
RESULT REMARKS NOTES
FINAL" BLD
BOND INFORMATION
ATTACHMENTS
REMARKS
CREATED
OWNER
DESCRIPTION
RETURNED
REVIEWS
STATUS
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
52-450 AVENIDA
0
NOTES
DAIZ.docx
DAIZ.docx
DATE
1ST REVIEW -
NON-STRUCTURAL-
JIM JOHNSON
6/12/2015
6/26/2015
6/29/2015
REVISIONS REQUIRED
BRES 2015-0234
0
TRANSMITTAL
(ist).pdf
STRUC CALLS ARE REQUIRED
2 WK
NON-STRUCTURAL-
JIMJOHNSON
7/24/2015
8/7/2015
8/12/2015
APPROVED
2 WK
KATHRYN
7/24/2015
8/7/2015
8/12/2015
READY FOR APPROVAL
STRUCTURAL - 2 WK
SAMUELS
BOND INFORMATION
Printed: Tuesday, August 25, 2015 12:11:19 PM 4 of 4 Orp
SYSTEtitS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME SUBDIR
ETRAKIT ENABLED '
DOC
6/29/2015
JIM JOHNSON
52-450 AVENIDA
52-450 AVENIDA
0
DAIZ.docx
DAIZ.docx
1ST REVIEW -
NEW CITY TRANSMITTAL
DOC
8/12/2015
KATHRYN SAMUELS
STRUCTURAL
BRES 2015-0234
0
TRANSMITTAL
(ist).pdf
Printed: Tuesday, August 25, 2015 12:11:19 PM 4 of 4 Orp
SYSTEtitS
A
�
: .:::...:>::»;<Telephone: ...::::
RE
tin #
Project (circle one):: Neww Add'n Alter Repaira,r Demo
City of La Quinta JUN 1'2 2015
Building & Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012 CppCITY OF LA QUIZ
Building Permit Application and Tracking 5 � e MIN DEVEL.0
Permit #
Project Address: 7 4 �
Ave n� b� Z
Owner's Name: (, � 0. Z ct
LA (F r
A. P. Number:
H
Address: V e h
' j. �� '� ( Z
Legal Description:
Contractor:
'B d
City, ST, Zip: L. q D '
Telephone: e.
Address: 0
Project Description: R e S %, A« 1 y 1 re p4
City, ST, Zip:
d tr
Amount
Telephone:
Structural Cates.
- ..........................................
Reviewed, ready for corrections
State Lic. :
,..
CityLic. #.:
C Rc0 0"1
`✓ n
,� OAW.
Yy��. �
Arch., Engr., Designer: r{n
Sp k h r o e%
/
Address: L f fA D it,' u e
Title 24 Cates.
City, ST, Zip: "e M � +-
G W & Z. 5 1-I L�
Plans picked up
A
�
: .:::...:>::»;<Telephone: ...::::
nstruction Type: Occupancy:
State Lic. #
Project (circle one):: Neww Add'n Alter Repaira,r Demo
Name of Contact Person: ^
Sq. Ft.: LK4
# Stories:
# Units:
Telephone # of Contact Person:
Estimated Value of Project: 1 L,> 0 K
APPLICANT: DO NOT WRITE BELOW THIS LINE
H
Submittal
Req'd
Rec'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Cates.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Ch lance
Title 24 Cates.
Plans picked up
Constructs n
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2nd Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
C
BUILDING ENERGY;ANALYSIS REPORT
PROJECT:
Residence
52450 Avenida Diaz
-La Quinta, CA
Project Designer:
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DA0I16 K� BY
SF
. Desert Builders Inc. •`
71537 Highway 111, Suite A
Rancho Mirage, Ca 92270
760-568-1793
Report Prepared by:
Joan D. Hacker
Insu=form, Inc.
77810 Las Montanas Road, Suite 201
Palm Desert, Ca 92211
760-345-1352
Job Number:
Date:
10/13/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
Ener Pro 6.7 by Ener Soft User Number: 2655 /D:
I TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF -1 R -PRF -01-E Certificate of Compliance 3
Form RMS -1 Residential Measures Summary 10
Form MF -1 R Mandatory Measures Summary 11
HVAC System Heating and Cooling Loads Summary15
{
EnergyPro 6.7 by EnergySoft Job Number: ID: User Number: 2655
M
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 16:32, Tue, Oct 13, 2015
Calculation Description: Title 24 Analysis
Input File Name: Residence Avenida Diaz Renovation.xml
CF1 R -PRF -01
Page 1 of
GENERAL INFORMATION
01
Building Complies with Computer Performance
01
Project Name Single Fam Detached
03
This building incorporates one or more Special Features shown below
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location 52450 Avenida Diaz
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 180
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2) 1276
15
Number of Zones 1 -
16
Slab Area (ft) 1276
17
Number of Stories 1
18
Addition Cond. Floor Area 0
19
Natural Gas Available Yes
20
Addition Slab Area (ft) 0
21
Glazing Percentage (%) 20.1%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building DOES NOT require HERS Verification
03
This building incorporates one or more Special Features shown below
06
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08252015-744
HERS Provider:
Report Generated at: 2015-10-13 16:32:30
I/
ENERGY USE SUMMARY
04
- 05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
2.22
2.20
0.02
0.9%
Space Cooling
218.22
204.01
14.21
6.5%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
20.33
20.33
0.00
0.0%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
240.77
226.54
14.23
5.9%
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08252015-744
HERS Provider:
Report Generated at: 2015-10-13 16:32:30
I/
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Single Fam Detached Calculation Date/Time: 16:32, Tue, Oct 13; 2015 Page 2 of -7
Calculation Description: Title 24 Analysis Input File Name: Residence Avenida Diaz Renovation.xmi
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• -- None —
Cooling System Verifications:
• —None —
HVAC Distribution System Verifications:
• --None —
Domestic Hot Water System Verifications:
•
--None —
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system. ,
Reference Energy UseEnergy,Design
Rating; J�
Margin Percent Improvement
Total Energy (kTDV/f2-yr)* 298.86
�, 284.63 ;
14.23 4.8%
' includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Single Fam Detached
1276
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Existing Living
Conditioned
Living Zonel
1276
9
DHW Sys 1
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-13 16:32:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 16:32, Tue, Oct 13, 2015
Calculation Description: Title 24 Analysis
Input File Name: Residence Avenida Diaz Renovation.xml
CF1 R -PRF -01
Page 3 df'7
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door
Area (ft2)
Tilt
(deg)
Status
Verified
Existing
Condition
Front Wall
Existing Living
Default Wall 1978 to 1991
180
Front
450
18
90
Existing
No
Left Wall
Existing Living
Default Wall 1978 to 1991
270
Left
350
89.984
90
Existing
No
Rear Wall
Existing Living
Default Wall 1978 to 1991
0
Back
450
63.984
90
Existing
No
Right Wall
Existing Living
Default Wall 1978 to 1991
90
Right
350
84.4208
90
Existing
No
Roof
Existing Living
Default Roof 1978 to Pres
Insect Screen (default)
Altered
1276
Window 5
Rear Wall (Back -0)
Existing
No
ATTIC
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Height (ft)
Multiplie
r
Radiant
U -factor
Statu
Verified Existing
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Barrier
Cool Roof
s
Condition
Insect Screen (default)
Altered
N/A
Window 2
Left Wall (Left -270)
6.0
6.8
0.98
Ex9 ti
0.33
Attic Existing Living
Attic RoofExisting Living
Ventilated
0
0.1
0.85
No
No
1
No
0.34
0.30
Insect Screen (default)
Altered
N/A
Window 4
Rear Wall (Back -0)
6.0
6.8
0.98
WINDOWS
01
02
03
.04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Height (ft)
Multiplie
r
Area (ft2)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
Window
Front Wall (Front -180)
3.0
5.0
1.2
18.0
0.34
0.30
Insect Screen (default)
Altered
N/A
Window 2
Left Wall (Left -270)
6.0
6.8
0.98
40.0
0.33
0.31
Insect Screen (default)
Altered
N/A
Window 3
Left Wall (Left -270)
10.0
5.0
1
50.0
0.34
0.30
Insect Screen (default)
Altered
N/A
Window 4
Rear Wall (Back -0)
6.0
6.8
0.98
40.0
0.33
0.31
Insect Screen (default)
Altered
N/A
Window 5
Rear Wall (Back -0)
6.0
4.0
1
24.0
0.34
0.30
Insect Screen (default)
Altered
N/A
Window 6
Right Wall (Right -90)
3.0
5.0
1
15.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 7
Right Wall (Right -90)
4.0
4.0
1
16.0
0.34
0.30
Insect Screen (default)
Altered
N/A
Window 8
Right Wall (Right -90)
8.0
6.8
0.982
53.4
0.33
0.31
Insect Screen (default)
Altered
N/A
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-10-13 16:32:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 16:32, Tue, Oct 13, 2015
Calculation Description: Title 24 Analysis
Input File Name: Residence Avenida Diaz Renovation.xml
CF1 R -PRF -01
Page 4 of
OVERHANGS AND FINS
01
02 03 04 05 06
07 08 09 10
11 12 13 14
05
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up Dist R
Bot Up
Window
2
0.1
2
2 0
0
0
0
0
0
0 0
0
Window 2
2
0.1
2
2 0
0
0
0
0
0
0 0
0
Window 3
2
0.1
2
2 0
0
0
0
0
0
0 0
0
Window 4
2
0.1
2
2 0
0
0
0
0
0
0 0
0
Window 5
2
0.1
2
2 0
0
0
0
0
0
0 0
0
Window 6
2
0.1
2
2 0
0
0
0
0
0
0 0
0
Window 7
2
0.1
2
2 0
0
0
0
0
0
0 0
0
Window 8
2
0.1
2
2 0
0
0
0
0
0
0" 0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
09
Name
Zone
Total Cavity
Winter Design
Edge Insul. R -value
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
35-
R-5, 8 inches
0.8
No
Existing
No
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofExisting Living
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity / Frame: R-11 / 2x4
• Exterior Finish: Wood
Default Wall 1978 to 1991
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 11
0.103
Siding/sheathing/decking
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
Default Roof 1978 to Pres
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 19
0.049
Over Floor Joists: R-9.9 insul.
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Slab -on -Grade
Existing Living
1276
35-
R-5, 8 inches
0.8
No
Existing
No
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-10-13 16:32:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 16:32, Tue, Oct 13, 2015
Calculation Description: Title 24 Analysis
Input File Name: Residence Avenida Diaz Renovation.xml
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required ---
CF1 R -PRF -01
Page 5 of•7
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
Annual
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.52 EF
40000-Btu/hr
0
0.04
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS -
01
02
03
04
05
06
07
08
09
Heating System
Cooling System
Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
Living Zone1
Other Heating and
Heating
Yes
Cooling
Yes
Air Distribution
HVAC Fan
1276
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 78 AFUE
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-10-13 16:32:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 16:32, Tue, Oct 13, 2015
Calculation Description: Title 24 Analysis
Input File Name: Residence Avenida Diaz Renovation.xml
CF1 R -PRF -01
Page 6df7
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
07
08
Efficiency
10
Multi -speed
Verified Duct Location
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
10
12
No
No
N/A
Location
system
Status
.
Verification
Air Distribution
Ducts located in attic
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Duct Leakage
Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
4.2
Attic
Attic
None
Existing
No
N/A
System 1
specified)
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05 1 06
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1 -hers -dist
N/A
IAQ (Indoor Air Quality) FANS
01 02' 03 04 05
Name IAQ CFM IAO Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
r -
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-10-13 16:32:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 16:32, Tue, Oct 13, 2015
Calculation Description: Title 24 Analysis
Input File Name: Residence Avenida Diaz Renovation.xml
CF1 R -PRF -01
Page 7of7
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Joan D. Hacker
Company:
Signature Date:
Insu-form, Inc.
10/13/2015
Address:
CEA/HERS Certification Identification (If applicable):
77810 Las Montanas Road, Suite 201
City/State i :
Im Desert, Ca 92211
Phone:
760-345-1352
RESPONSIBLE PERSON'S DECLARATION STATEMENT -
I certify the following under penalty of perjury, under the laws of"the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Mark Davis
Company:
Date Signed:
Desert Builders Inc.
10/15/2015
Address:
License:
71537 Highway 111, Suite A
472150
City/State/Zip:
Phone:
Rancho Mirage, Ca 92270
760-568-1793
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-10-13 16:32:30
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Residence
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
10/13/2015
Project Address
52450 Avenida Diaz La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
1,276
Addition
0
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features
Status
Wall Wood Framed R 11 1,344
Existing
Roof Wood Framed Attic R 19 1,276
Existing
Slab Unheated Slab -on -Grade R 5 1,276 Perim = 35'
Existing
FENESTRATION I Total Area: 256 Glazing Percentage: 20.1 o New/Altered Average U -Factor:
Orientation Area ft2 U -Fac SHGC Overhang Sidefins Exterior Shades
0.33
Status
Front (S) 18.0 0.340
0.30 2.0 none Bug Screen
Altered
Left (W) 40.0 0.330
0.31 2.0 none Bug Screen
Altered
Left (W) 50.0 0.340
0.30 2.0 none Bug Screen
Altered
Rear (N) 40.0 0.330
0.31 2.0 one Bug Screen
Altered
Rear (N) 24.0 0.340
0.30 2.0 none Bug Screen
Altered
Right (E) 15.0 0.710
0.73 2.0 none Bug Screen
Existing
Right (E) 16.0 0.340
0.30 2.0 none Bug Screen
Altered
Right (E) 53.4 0.330
0.31 2.0 none Bug Screen
Altered
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat
Status
1 Central Furnace 78% AFUE
Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value
Status
Living Zone Ducted
Ducted Attic 4.2
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution
Status
Ener Pro 6.7 by Ener Soft User Number. 2655
RunCode: 2015-10-13716:35:17 ID:
Pae 10 of 15
2013'Low-Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CF 1 R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ 150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ 150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ 150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class 11 vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§ 150.0(g)1:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ 150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ ] 50.0(e) I A:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)IB:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§ 150.0(e) I C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ I50.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §I 10.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§ 150.0(h)1:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in § 150.0(h)2.
§ 150.0(h)3A:
installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 1 10.2(c).
§ 150.0(j)IA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150.00)]B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§ 150.00)2C:
Pipe for cooling system lines shall be insulated as specified in § I50.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, iricluding that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ 150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§ I50.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual. dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category Ill or 1V vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)1:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than Y< inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ 150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ 150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§ 150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§I50.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§ 150.0(m)13:
space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ I50.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of 5 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§ 150.0(0)1 A:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 1 10.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ 150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§ 150.0(k) I A:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§ 150.0(k) I B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)1 C:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§ 150.0(k)ID:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k) I E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)IF:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of §150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ 150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it
§ I50.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of ' 130.5; and all other requirements in ' 150.0(k)2.
§ I50.0(k)21:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§ 150.0(k)3 A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ I50.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ I50.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ I50.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§I50.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ 150.0(k)9B:
following requirements:
i. Shall comply with § 150.0(k)9A; or
ii. Shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comp@y with the applicable requirements in $110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)10:
Internally illuminated address: signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ 150.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9, § 130.0, § 130. 1, § 130.4, § 140.6, and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k) I2A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ 150.0(k)1213:
i, Comply with the applicable requirements in § 110.9, § 130.0, § 130. 1, § 140.6 and § 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 1 10.10(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of ' 110.10 b through ' 110.10 e .
§ 1 10.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 1 10.10(b) through § 1 10.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 1 10.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 1 10.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 1 10.10(b) through § 1 10.10(c)
shall be provided to the occupant.
§ 110.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
MVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Residence
Date
10/13/2015
System Name
Living Zone
Floor Area
1,276
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,436
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System 70,000
19,954
1,194
541
16,560
Total Output Btuh 70,000
0
Output Btuh/s ft 54.9
1,692
1,177
Cooling System
0
0
Output per System 58,000
0
0 0
0
Total Output (Btuhl 58,000
0
1,194
0
Total Output Tons 4.8
1,692
1,177
Total Output Stuh/sgft 45.5
Total Output s ft/Ton 264.0
1 23,338
18,913
Air System
CFM per System
2,210
HVAC EQUIPMENT SELECTION
Airflow cfm
2,210
Existing
34,084
20,220
70,000
Airflow cfm/s ft
1.73
Airflow cfm/Ton
457.2
Outside Air %
0-0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
34,084
20,220
Aug 3 PM
70,000
Outside Air cfm/s ft 0.00
Jan 1 AM
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF
Outside Air
0 cfm
69 OF
14
69 OF 99 OF 99 OF
t a
Heating Coil Supply Fan
2,210 cfm
x
99 OF
��RQ�OM
70 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112/78°F
Outside Air
0 cfm
79/68°F
79/68°F 64/63°F 64/63°F
Cooling Coil Supply Fan
2,210 cfm
65 / 64 OF
60.1 %
78/68°F
EnergyPro 6.7 by EnergySoft
User Number: 2655 RunCode: 2015-10-13716:35:17
ID: