11285 (SFD)E - �44 '� r
P.O. BOX 1504 No. 11285
Buildingr 7&105 CALLE ESTADO
52.'-7
Address 70 Diaz LA QUINTA, CALIFORNIA 92253
Owner
David Miller �
BUILDING: TYPE CONST. OCC: GRP.
Mailing
Address P. vi . Box 722
City Zip Tel.
La Quinta 92253
Contractor
Pacific 'Trades
Address
Sc�.1Ct^t,-
P. Number
Description
State Lic. City
& Classif. $ 425381 Lic. # 1955 Sq. Ft.
Size -
Arch.; Engr.,
Designer New ❑
Address I Tel.
City (Zip (State I
Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and
effect
,,r4GNATl1RE — DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a
permit to construct, alter. Improve, demofsh, or repair any structure,- prior to its issuance also
requires the applicant for such permit to Ide a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencingwith Section 7000) of�
Division 3 of the Business and Professions' Code, or, that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for �a permit
subjects the applicant to a civil penalty ofTrot more than five hundred dollars.($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an -owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose or sale.)
b I, as Owner of the property, am exclusively contracting with licensed contractors to con,
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's" License Law
does not apply to an owner of property*who builds or improves thereon, and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Poljcy No. Company
Copy is filed with the city. ❑ Certified copy is hereby furnished. .
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed it the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the Workers' Compensation
Laws of Cal fornia.
Date Owner
NOTICE TO APPLICANT. If, after making this Certificate or Exemption you . should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Ciwl Code.)
Lender's Name
Lender's Address
— This is a building permit when property filled out, signed and validated, and is subject to
expiration it work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building -
construction,* and hereby authorize representatives -of this city to enter the 'above.
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
Description
SPD
Stories Stories
Add ❑ Alter ❑
At does not incl
No. Dw.
Units
Repair ❑ Demolition ❑
11
Estimated Valuation
76,815.50
' PERMIT
AMOUNT
Plan Chk: Dep.
250.00
Plan Chk. Bal.
218.20
Const.
1 545.00
Mech.
55.50
Electrical
'-.117.58
Plumbing
,141.00 .
S.M.I.
` 7.70
Grading
. 20.00
Driveway Enc.
.00
Infrastructure
1690.10
TOTAL
s^,,,304-54,0 83 v± -1 i
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by: Date Permit
Validated by:
Validation:
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
F
NO. PLUMBING FEES '
�
1ST FL. SO. FT. ® $
UNITS
COLL. AREA
2ND FL. SO. FT.
ROUGH PLUMB.
YARD SPKLR SYSTEM
BONDING
MOBILEHOME SVC.
BAR SINK
POR. SO. FT. ®
SEWER OR SEPTIC TANK
GAR. SO. FT. ®
POWER OUTLET
ROOF DRAINS
FOUND. REINF.
GAS (ROUGH)
DRAINAGE PIPING
CARP. SO. FT. ®
HEATING (FINAL)
OTHER APPJEQUIP.
WALL SO. FT. ®'
GAS (FINAL)
DRINKING FOUNTAIN.
SO FT ®
URINAL
ESTIMATED CONSTRUCTION VALUATION $
WATER HEATER
WATER PIPING
NOTE: Not to be used as property tax valuation
FINAL INSP.
FLOOR DRAIN
MECHANICAL FEES
WATER SYSTEM
WATER SOFTENER
VENT SYSTEM. FAN EVAP.COOL HOOD
SIGN
WASHER(AUTO)(DISH)
APPLIANCE DRYER
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
ROOFING 9 G
LAUNDRY TRAY
AIR HANDLING UNIT CFM
KITCHEN SINK
ABSORPTION SYSTEM. B.T:U.
TEMP USE PERMIT SVC
WATER CLOSET'
COMPRESSOR HP
POLE, TEMIPERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER. B.T.U.
SO. FT. ® c
BATH TUB
SO. FT. ® c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SO. FT. RESID ® 11/4 c
SEWAGE DISPOSAL
SO.FT.GAR ® V4c
HOUSE SEWER
GAS PIPING
PERMITTEE
PERMIT FEE
PERMIT FEE .
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE -
SMI FEE PLUMB. FEE
STRUCTURE /PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
9
SETBACK
GROUND PLUMBING �1
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE
ROUGH PLUMB.
BONDING
HEATING (ROUGH) '
STORAGE TANK
FORMS
SEWER OR SEPTIC TANK
ROUGH WIRING.
DUCT WORK
ROCK STORAGE
FOUND. REINF.
GAS (ROUGH)
METER LOOP
HEATING (FINAL)
OTHER APPJEQUIP.
REINF. STEEL 7
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
FINAL INSP.
vc
•
GRADING
cu. yd.
$ plus x$
-$
LUMBER GR.
FRAMING Lb
FINAL INSP. ! `
ROOFING 9 G
p�
1
REMARKS:
VENTILATION
FIRE ZONE ROOFING:
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
HING
MESH
INSULATIONISOUN
FINISH GRADING
FINAL INSPECTION '
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURESIINITI ALS.
GARDEN WALL FINAL
F I NNELL COMPANY
7146593961
P. 02
/ER METHOD SUMMARY Page 1 C -2R
/bject- Title ==-=.......... PACIFIC -__-_-==�-----==----==-Date ., .. . _06/34/92
project Address..,..... LA QUINTA
Documentation Author... W J FINNELL
Building. Permit # ;
Company ..............., ENERGY CONSULTING GROUP
Telephone .............. 800-262-9966 Plan Check / Date ;
Compliance Method......
,•• MICROPAS3 by Enercomp, Inc. ;FieldCheck/Date
Climate Zone..:..... 15---------------------
- - ---___
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM C -2R ,
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC
------------------------------------------------------------------------------
M I CROPAS3 ENERGY -USE SUMMARY
------------------------------
- Energy Use
Standard
Proposed
Compliance =
- (kBtu/sf-yr)
Design
Design
Margin -
= Space Heating..........
6.55
2.92
3.63 =
= Space Cooling..........
47.56
42,38
5.18 -
= Water Heating..........
14.88
21.97
-7.09 -
= Total
68.99
67.27
1.72 -
_* Building complies
with Computer
Performance
GENERAL INFORMATION
-------------------
Conditioned Floor Area.....
Building Type........ ....
Building Front Orientation.
Number of. Dwelling Units...
Number of Building Stories.
Weather Data Type..........
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Footprint Area .............
Slab -On -Grade Area........,
Glazing Percentage.........
Average Ceiling Height.....
1257 sf
Single Family
Front Facing
1
1
Reduc.edYear
Detached
270 deg (W)
S1ab'On Grade (Package D)
1.
10936 'cf
1257 sf
1257 sf
10.8 % of FA
8.7 ft
BUILDING ZONE INFORMATION
a -------------------------
Floor # of Vent Special
Cond- Area Volume Dwell Thermostat Height Vent Area
Zone Type itioned (sf) (cf) Units Type (ft) (sf)
HOUSE
Residence Yes 1257 10936 1.00 Setback 2.0 n/a
a
FINNELL COMPANY 7146593961 P.03
COMPUTER METHOD SUMMARY Page 2 C-213
Project Title.......... PACIFIC ^- _- �y--- - -^^Date ........ -06/30/92
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM C -2R
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC `
------------------------------------------------------------------------------
OPAQUE SURFACES
GLAZING SURFACES
----------------
Area
Area
U-
Insul Act
(sf)
Solar
Location/
Form 3
Surface
(sf)
value R-val Azmth
Tilt
Gains
Comments
Reference
HOUSE
Act
50% bug scrn
Glass
Shade
GIs+
Surface
(sf)
1
Wall
64
0.065
R-19 270
90
Yes
OUTSIDE
None
2
wall
160
0.065
R-19 270
90
No
GARAGE
None
3
Wall
252
0.065
R-19 0
90
Yes
OUTSIDE
None
4
Wall
198
0.065
R-19 90
90
Yes
OUTSIDE
None
5
Wall
204
0.065
R-19 180
90
Yes
OUTSIDE
None
6
Roof
1257
0.029
R-38 0
0
Yes
ATTIC
None
7
Door
20
0.330
R-2 270
90
Yes
OUTSIDE
None
0.66
PERIMETER LOSSES
Length F2
Insul
Surface
(ft)
Factor
R-val
Location/Comments
HOUSE
8 S1abEdge
9
0.900
R-0
TO
OUTSIDE
9 S1abEdge
116
0.720
R-0
TO
OUTSIDE
10 S1abEdge
20
0.550
R-0
TO
GARAGE
GLAZING SURFACES
----------------
EXTERIOR SHADING
Area
Shading
SC of
Surface
(sf)
Type
Ext Shade
SC
Interior
SC
Area
# of
Frame
Open
U-
Act
50% bug scrn
Glass
Shade
GIs+
Surface
(sf)
Panes
Type
Type
value
Azmth
Tilt
Only
Type
Shade
HOUSE
1 Window
26.0
2
Metal
Slider
0.65
270
90
0.77
drapes
0.66
2 Window
16.0
2
Metal
Slider
0.65
0
90
0.77
drapes
0.66
3 Window
49.0
2
Metal
Slider
0.65
90
90
0.77
drapes
0.66
4 Window
45.0
2
Metal
Slider
0.65
180
90
0.77
drapes
0.66
EXTERIOR SHADING
Area
Shading
SC of
Surface
(sf)
Type
Ext Shade
HOUSE
1 Window
26.0
50% bug scrn
0.84
2 Window
16.0
50% bug scrn
0.84
3 Window
49.0
50% bug scrn
0.84
4 Window
45.0
50% bug scrn
0.84
:-------------------------------------------------------------------------
-----
- FINNE LL COMPANY 71 4659396 1 P.04
COMPUTER METHOD SUMMARY Page 3 C -2R
Project Title.......... PACIFIC - _- ---Date ........ �06/30/92
i MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM C-213
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC ;
---------------------------------------------------------------------------------
THERMAL MASS
HVAC SYSTEMS
Area
Thick
Heat
Conduct-
Surface
Efficiency
Mass Type
---------------
(sf)
------
(in)
-----
Cap
-----
ivity
--------
R -value
--------
Location/Comments
--------------------------
HOUSE
HeatPump
8.0 HSPF
Attic
R-5
0.828
AirCond
1 SlabOnGrade
210
3.5
28.0
0.98
R-0
KIT/BATHS
2 S1abOnGrade
1047
3.5
28.0
0.98
R-2
REST OF HOUSE
3 InteriorHorz
54
1.0
24.0
0.67
R-0
TILE: BATHS/KITCHEN
4 InteriorVert
72
4.0
21.0
0.59
R-0
FIREPLACE
HVAC SYSTEMS
WATER HEATING SYSTEMS
Minimum
Duct
Duct
Duct
System Type
Efficiency
Location
R -value
Efficiency
HOUSE
(Btuh) Credits
Storage
'
HeatPump
8.0 HSPF
Attic
R-5
0.828
AirCond
10.00 SEER
Attic
R-5
0.818
WATER HEATING SYSTEMS
SPECIAL FEATURES/REMARKS
-----------------------
Capa-
R-12 or
Pilot
System
# of city
Greater Effic- Standby input
Size
Type
Heat (gal)
Blanket iency Loss Rating
(Btuh) Credits
Storage
'
Electric
1 37
No 0.99 RE .82% 4.5 kW
n/a Recovery
SPECIAL FEATURES/REMARKS
-----------------------
----------------------------------------
FINNELL COMPANY 7146593961 P.05
WATER HEATING Page 1 DHW
-------------------------------===----=-------------.
Project Title.......... PACIFIC M - - Date....... 06/30/92
Project Address........ LA QUINTA ---------------------
Documentation Author... W J FINNELL ; Building Permit #
Company ................ ENERGY CONSULTING GROUP
Telephone .............. 800-262-9966 Plan Check / Date
Compliance Method...... MICROPAS3 by Enercomp, Inc.
Climate ;FieldCheck/Date
Zone.... .. . . . . . 15
----
' MICROPAS3 v3.11 File -PACIFIC. Wth-CTZ15 Program -WATER -HEATING - -
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC ;
-------------------------------------------------------------------------------
WORKSHEET ONE: STORAGE GAS OR STORAGE ELECTRIC
A. EQUIPMENT DATA
-----------------
1. Water heater type.......
2. Manufacturer............
3. Model number............
4. Ignition device.........
5. Tank volume. .........
6. Recovery efficiency.....
7. Standby loss............
8. Rated Input.. ..........
9. Number of Heaters.......
10.Insuiation Jacket.......
Storage, Electric
n/a
37 gal
.99 percent x 0.01
.0082 percent/hour x 0.01
-15358.5 Stu/hr
1
No
B. OPERATING DATA
-----------------
1. Climate Zone.. ......
2. Water heating budget....
3. Tank set temp...........
4. Water main tamp.........
5. Daily hot water load....
S. Ambient air temp........
7. Adj. Standby Losses.....
8. No. dwelling units.......
9. Pump power ..............
10.Pumping energy..........
15
18700 kBtu/yr/unit
140 F
70 F
50 gal
72.6 F.
.0082
1
0 Watts (0 Watts controller)
0 Watt-hr/yr (0 hr per day)
C. WATER HEATING ENERGY CREDITS
-------------------------------
1. Credit Name............. Recovery
2. Annual savings.......... 2805 k8tu/yr/unit
D. ANNUAL WATER HEATING
ENERGY
1.
------------------------------
Recovery load...........
10539
kBtu/yr
2.
Recovery energy.........
7813
kBtu/yr
3.
Standby loss anergy.....
1392
kBtu/yr
4.
Pumping energy..........
0
kBtu/yr source
5.
Total energy............
27614
kBtu/yr/unit source
6.
Comparison ..............
-8914
k8tu/yr/unit source
7.
Points.. .............
-14
8.
Water Heating -Energy Use
21.97
kStu/yr/sf
(D5 x 88) / 1257 sf
FINNELL COMPANY 7146593961 P.06
HVAC SIZING Page 1 HVAC
Project Title...,. .... PACIFIC ----------M~- ---==-"Date ........ 06/30/92
Project Address........ LA QUINTA --•-------------------
Documentation Author... W J FINNELL ; Building Permit #
Company ................ ENERGY CONSULTING GROUP
Telephone.............. 800-262-9966; Plan Check / Date ;
Compliance Method...... MICROPAS3 by Enercomp, I.nc. ; Field Check/ Date
Climate Zone........... 15 ------------.-.--------
` MICROPAS3 0.11 File -PACIFIC yWth-CTZ15- Program -HVAC SIZING -�
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC '
GENERAL INFORMATION
Floor Area ................. 1257 sf
Volume ..................... 10936 cf
Front Orientation.......... Front Facing 270 deg (W)
Sizing Location............ INDIO
Latitude... .... ... 33.7 degrees
Winter Outside Design...... 29 F
Winter Inside Design....... 70 F
Summer Outside Design...... 112 F
Summer Inside Design....... 78 F
Summer Range ............... 30 F
Shading Used.... ......... No
Latent Load Fraction....... 0.20
HEATING AND COOLING LOAD SUMMARY
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
CEC Maximum output applicable for gas central furnaces only
Heating
Cooling.
Description
(Btuh)
(Stuh)
Opaque Conduction and Solar......
8312
3918
Glazing Conduction ...............
3624
3006
Glazing Solar ....................
n/a
5509
Infiltration .....................
6449
3822
Internal Gain ....................
n/a
2550
Ducts ............................
1839
1880
Sensible Load ....................
20224
20685
Latent Load ......................
n/a
4137
Total Load
20224
24822
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
CEC Maximum output applicable for gas central furnaces only
a
FINNELL COMPANY 7146593961
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
Project Title.......... PACIFIC Date........ 06/30/92
Project Address........ LA QUINTA------------
Documentation Author... W J FINNELL !'
Building Permit # ,
Company ................ ENERGY CONSULTING GROUP ;
'telephone .............. 800-.262-9966 ; Plan Check / Date ;
Compliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date ;
Climate Zone........... 15 ---------------------
MICROPAS3 v3.11 -File-PACIFiC- Wth-CTZ15 Program -FORM CF -1R y---
User#-MP1325 User -ENERGY CONSULTING GROUP Run-PACIFIC
--------------------------------------------------------------------------------
GENERAL INFORMATION
Conditioned Floor Area..... 1257 sf
Building Type .............. Single Family Detached
Building Front Orientation.' Front Facing 270 deg (W)
Number of Dwelling Units... 1
Number of Stories.......... 1
Floor Construction Type.... Slab On Grade (Package D)
Infiltration Control....... Standard
BUILDING SHELL INSULATION
-------------------------
Component Insul
Type R -value Location/Comments
wall' R-19 OUTSIDE, GARAGE
Roof R-38 ATTIC
Door R-2 OUTSIDE
SlabEdge R-0 JO OUTSIDE, TO GARAGE
GLAZING
Glazing
Area
# of
Interior
Exterior
Framing
Orientation
(sf)
Panes
Shading
Shading Overhang
Type
Window Front (W)
26.0
2
drapes
50% bug scrn None
Metal
Window Left (N).
16.0
2
drapes
50% bug scrn None
Metal
Window Back (E)
49.0
2
drapes
50% bug scrn None
Metal
Window Right (S)
45.0
2
drapes
50% bug scrn None
Metal
THERMAL MASS
Area Thickness
------------
Hard Surfaced/
Type
(sf)
(in)
Exposed
-------------
Location/Comments
; -- ------------------------
------------ ------
SlabOnGrade
---------
210
3.5
Yes
KIT/BATHS
S1abOnGrade
1047
3.5
No
REST OF HOUSE
InteriorHorz
54
1.0.
Yes
TILE: BATHS/KITCHEN
InteriorVert
72
4.0
Yes
FIREPLACE
FINNELL COMPANY 7146593961 P.08
CERTIFICATE OF COMPLIANCE:.RESIDENTIAL. Page 2 CF -1R
Project -Title........ PACIFIC-------------~ Date.. .... 06/30/92
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM CF -1R
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC
ASSUMED HVAC SYSTEMS
Assumed
Duct
Duct
Assumed System Efficiency
Location
R -value
HeatPump 8.0 HSPF
Attic
R-5
AirCond 10.00 SEER
Attic
R-5
ACTUAL HVAC SYSTEMS
Actual Output Manufacturer and Model #
Actual System Efficiency (Stub) (or approved equal)
Heating
Cooling
Cooling Coil
CEC Maximum output for Gas Central Furnaces: Stuh
WATER HEATING SYSTEMS
Tank R-12 or
# of Vol Greater Manufacturer and Model # Energy
System Type Heat (gal) Blanket (or approved equal) Credits
Storage, Electric -1 37 No Recovery
SPECIAL FEATURES/REMARKS
-----------------------
- - -------------------------------------------------------------------------------
FINNELL COMPANY 7146593961
----------
P.09
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
Project Title.......... PACIFIC Date........ 06/30/92
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM CF -1R ;
User#-MP1325 User -ENERGY CONSULTING GROUP Run-PACIFIC
--------------------------------------------------------------------------------
COMPLIANCE STATEMENT
--------------------
This certificate of compliance lists the building features and performance
specifications needed to comply with Title 24, Chapter 2-53 and Title 20,
Chapter 2, Subchapter 4, Article 1 of the California Administrative code.
This certificate has been signed by the individual with overall design
responsibility and the building owner, who shall retain a copy of it and
transmit the certificate to any subsequent purchaser of the building. When
this certificate of compliance is submitted for a single building plan to
be built in multiple orientations, all building conservation features
which vary are indicated in the Special Features/Remarks section.
DESIGNER
Name....
Company.
Address.
Phone...
License.
Signed
(date)
DOCUMENTATION AUTHOR
Name.... W J FINNELL
Company. ENERGY CONSULTING GROUP
Address. 341= INDIAN HILLS
MTN CENTER, CA 92561
Phone... 800-262-9966
r
Signed a� L
(date)
kR
Name:... �S
company.
Address.
Lb 0.I6tai-It6 C.Q ---- -
Phone...
Signed
Name....
Title...
Agency..
Phone...
.Signed
(date)
ENFORCEMENT AGENCY
(date)
FINNELL COMPANY 7146593961 P.10
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF -1R
-------------------------------------------------------------------------------
Project Title.......... PACIFIC Date........ 06/30/92
Project Address........ LA QUINTA ---------------------
Documentation Author... W J FINNELL Building Permit #
Company ................ ENERGY CONSULTING GROUP I
Telephone .............. 800-262-9966 ; Plan Check / Date ;
Compliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date ;
Climate Zone........... 15 ---------------------
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM MF -1R
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC
------------------------------------------------------------------------------
Lowrise residential buildings subject to the Standards must cont::in these
measures regardless of the compliance approach used. items markea with an
asterisk (*) may be superseded by more stringent compliance requirements listed
on the Certificate of Compliance. When this checklist is incorporated into the
permit documents, the features noted shall be considered by all parties as
binding minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
--------------------------
Design- Enforce-
er ment
* 2-5352(a): Minimum ceiling insulation R-19 weighted average.
2-5352(b): Loose fill insulation manufacturers labeled R -Value.
* 2-5352(c): Minimum wail insulation in framed walls R-11
weighted average (does not apply to exterior mass walls).
2-5352(k): Slab edge insulation - water absorption rate no
greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
2-5311: insulation specified or instal ' led meets CEO quality
standards. Indicate type and form.
2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16.
2-5317: Infiltration/Exfiltration Controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
b. Doors and windows certified.
c. Doors and windows weatherstripped; all joints and
penetrations caulked and sealed.
2-5352(e): Special infiltration barrier installed to
comply with Sec. 2-5351 meets CEC quality standards.
2-5352(d): Installation of Fireplaces
1. Masonry and factory -built fireplaces have: i
a. Tight fitting, closeable metal or glass door
b. Outside air intake with damper and control
---- ._,. e.1- 9nr4 rnnt•.rnl
-� - -------------.------
FINNELL COMPANY 7146593961 P.11
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF-iR
Project Title... ...... PACIFIC-ww--------------Date ........ 06/30/92
MICROPA53 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM MF -1R
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC ;
HVAC AND PLUMBING SYSTEM MEASURES
---------------------------------
Design- Enforce-
er ment
2-5352(8) and 2-5303: Space conditioning equipment sizing:
attach calculations.
2-5352(h) and 2-5315: Setback thermostat on all applicable
heating systems.
* 2-5316(a): Ducts constructed, installed and insulated per
Chapter 10, 1976 UMC.
2-5316(b): Exhaust systems have damper controls.
2--5314(c): Gas-fired space heating equipment has
intermittent ignition devices.
2-5314: HVAC equipment, water heaters, showerheads and
faucets certified by the CEC.
2-5352(i): Water heater insulation blanket (R-12 or greater) for
storage and backup tanks for.so.lar water heating systems (first
5 feet of pipes closest to tank insulated to R-3 or greater),
2-5312(Exception 0: Pipe insulation on steam and steam
condensate return and recirculating piping.
2-5318(d): Swimming Pool Heating
1. System has:
a. On/off switch on heater.
b. Weatherproof instruction plate on heater.
c. Plumbed to allow for solar.
2. 75 percent thermal efficiency.
3. Pool cover.
4. Time clock.
5. Directional water inlet.
LIGHTING AND APPLIANCE MEASURES
-------------------------------
Design- Enforce-
er ment
2-53520): Lighting - 25 lumens/watt or greater for
general lighting in kitchens and bathrooms.
2-5314(c): Gas fired appliances equipped with
intermittent ignition devices.
r
2-5314(a): Refrigerators, refrigerator -freezers,
freezers and fluorescent lamp bal_Jasts certified by the CEC.
DESERT SANDS UNIFIED SCHOOL DISTRICT
82-879 Highway 111
NOTICE: Indio, CA 92201
Document Cannot Be Duplicated (619) 347-8631
Date 8/12/92 1 Type of Permit I La Quinta
No. 111646 Permit #
Owner Name David Miller Log #
No. 52770 street Diaz
city La Quinta zip 92253 Study Area 112
APN # I Tract # I Lot # = Square Footage 1 1257
Type of Development Single Family Residence No. of units
Comments
At the present time, the Desert Sands Unified School District does not collect fees on
garages/carports, covered patios/walkways, residential additions under 500 square feet,
detached accessory structures or replacement mobilehomes. It has been determined
the above-named owner is exempt from paying school fees at this time due to the
following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to Government Code 53080
in the amount of Fl—.5-8--1 X 11.257 or $ 1,986.06 have been paid to D.S.0 S.D. for
r
the property listed above and that building permits and/or Certificates of Occupancy for `
this square footage in this proposed project may now be issued
Fees Paid By David Miller
Name on the check
By James E. Lively
Assistant Superintendent, Business Services
Fee collected /exempted by Vickie J. Durrett
Signature ZLLi'a, /Ow��
Telephone
Payment Received
Check No. 3010
Collector: Attach a copy of county or city plan check application form to district copy for all waivers.
Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting
ARROW PRINTING. INDIO. CA 2500 11190 271213 -CJ
4
P.O. BOX 1504 No. 11285
Building 78-105 CALLE ESTADO
Address 52-770 Diaz LA QUINTA, CALIFORNIA 92253
Owner
David Miller BUILDING: TYPE CONST. OCC. GRP.
Mailing
Address P. O. BOX 722
A.P. Number
City Zip Tel.
La Quinta 92253 Legal Description
Contractor Project Description
Pacific Trades SFD
Address
same
City Zip Tel.
State Lic. City
8Classif.B 425381 Lic.# 1955 Sq.Ft.14c7- No. No.Dw.
Size Stories Units
Arch., Engr.,
Designer New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑
Address Tel. Permit does not
include block wall
City Zip State or pool
Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and
effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION Estimated Valuation
I hereby affirm that I am exempt from the Contractors License Law for the following 76,815.50
reason: (Sec. 7031.5,13usiness and Professions Code: Any City or county which requires e
permit to construct, atter, Improve, demolish, or repair any stricture, prior to Its issuance also
requires the applicant for such permit to rile a signed statement that he is licensed pursuant to PERMIT AMOUNT
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit Plan Chk. Dep. 250.00
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).
O 1, as owner of the property, or my employees with wages as their sole compensation, will Plan Chk. Bal. 218 . 20
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Const. 545 . 0 0
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or'approves thereon and who does such work himself or through his own employees, Mech.
provided that such improvements are not intended or offered for sale. If, however, the building
55 A 50
orImprovement is sold within one year of completion, the owner -builder will have the burden Electrical
117 58
of proving that he did not build or improve for the purpose of sale.)
❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- Plumbing 141 00
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or Improves thereon, and who contracts for S.M.I.
such projects with a contractors) licensed pursuant to the Contractor's License Law.)
Grading
❑ 1 am exempt under Sec. B. & P.C. for this reason
Driveway Enc. .00
Date Owner Infrastructure 1690 . 1 0
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Workers Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
Copy is filed with the city. ❑ Certified copy is hereby furnished.
TOTAL 10455 -OR 2795. 08
CERTIFICATE OF EXEMPTION FROM REMARKS
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of the work for which this permit is issued, I shall not
employ anyparson in any manner so as to become subject to the Workers' Compensation
Laws of California.
Date Owner
NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become ZONE: BY:
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith Minimum Setback Distances:
comply with such provisions or this permit shall be deemed revoked.
Front Setback from Center Line
Rear Setback from Rear Prop. Line
CONSTRUCTION LENDING AGENCY Side Street Setback from Center Line
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.) Side Setback from Property Line
Lender's Name
i Lender's Address FINAL DATE INSPECTOR
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
1 I certify that 1 have read this application and state that the above information is correct. Issued by: Date Permit
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives -of this city to enter the above-
mentioned property for Inspection purposes. Validated by:
Signature of applicant -Date-
Mailing
ateMailing Address Validation:
rilo Ch}n 71n
41ICIZVrAtg
v4z
Orr T -k
IjC�
( rpt of -14a:
�ut��tn �tn� �5•�t�e� . �t�t�tun
This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building
Code certifying that at the time of issuance this structure was in .compliance with the various
ordinances of the City regulating building construction or use. For the following:
BUILDING ADDRESS 52-770 AVENIDA DIAZ
Use Classification SINGLE FAMILY DWELLING Bldg. Permit No. 11285
Group R3 Type Construction VN Fre Zone Use Zone SR
Owner of Building DAVID MILLER Address P • 0. BOX 722
City LA QUINTA, CA 92253
By. LONNIE DAY
(^' 7 OCTOBER 20, 1992
Dote:
Building Official