Loading...
14041 (SFD)P.O. BOX 1504 Building J 53r-170 Ave. Diaz 78-105 CALLE ESTADO Address LA QUINTA, CALIFORNIA 92253 ""°ii`i Sterling Home Mailing P.O. Box 450 Address No. No. Dw. Stories Units New ❑ Add ❑ City Zip permit -to be;'obtafned separately. Tel. La Quinta, CA Rear Setback from Rear Prop. Line 92253 •564=•1866 CBn&,-B+t%t301 ventures, inn. $104 * 345 . t30 Address Box 450 �Y.�2�. AMOUNT Plan Chk. Dep. CiLtya Quinta, CA zIp92253 289.61 Te564-1866 State Lic. B , & Classif. 638535 Mech. City Lic. # 859 Arch:; Engr:, - - --- 132.90 Plumbing t' Designer s.M.l. 30.43 Address 20.00 Tel. City (Zip ( State Lic. # i LICENSED CONTRACTOR'S DECLARATION I hereby affirm. that I am licensed under provisions of Chapter 9 (commencing with Section X000) of,,Division 3 of the Buslhess and Professions,Code, and my license is in full force and Yeffect.�,,,k-�4f tx. �.. �Y.. W V t= kt;• yl r,✓� . /xv. s, ' IGNATURE DATE f OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law or the following reason:,(Sec. 7031.5,Susiness and Professions Code: Any city or„county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement,that he is licensed pursuant to the provisions o/ the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for`the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit - subjects the applicant to a civil penalty of not more than five hundred dollars ($500). I ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property,whol builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I ' I ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for • such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason i r Date Owner I WORKERS' COMPENSATION DECLARATION I herebyy,affirm that I have a certificate of consent to self -insure, or a certificate of Worker's,i6mpensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Pol'cY o• Company WCopy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name t Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. - I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above- mentioned property for inspection purposes. Signature of applicant -_ Date Mailing Address City, State, Zip No. 14041 ` 11LDING: TYPE CONST. 4 VN OCC. GRP. P. Number 774-042-010 egal Description Lot 15 Block 177 roject Description SPD R3 REMARKS n Sq. Ft. 1606 Size No. No. Dw. Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Permit includes garden block walls. Pool permit -to be;'obtafned separately. Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line - Estimated Valuation $104 * 345 . t30 PERMIT AMOUNT Plan Chk. Dep. 250..00 Plan Chk. Bal. 289.61 Const. _ 657.00 Mech. 55.50 � Electrical 132.90 Plumbing t' 141.00 s.M.l. 30.43 Grading 20.00 Driveway Enc. .00 Infrastructure 2,289.87 Arts in Public Places 20.00 Precise -Plan \ 25.00 TOTAL 3,891.31 3,641.31 REMARKS n ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line - Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING IST FL. SQ. FT. ® $ UNITS A.C. UNIT COLL. AREA SLAB GRADE YARD SPKLR SYSTEM 2ND FL. SQ. FT. BONDING HEATING (ROUGH) MOBILEHOME SVC. BAR SINK POR. SQ. FT. ® d SEWER ROUGH WIRING GAR. SO. FT. ® POWER OUTLET ROOF DRAINS FOUND. REINF. DRAINAGE PIPING CAR P. SQ. FT. ® HEATING (FINAL) WALL SQ. FT. ® REINF. STEEL DRINKING FOUNTAIN SO. FT. ® TEMP. POLE URINAL ESTIMATED CONSTRUCTION VALUATION $ WATER PIPING NOTE: Not to be used as property tax valuation WATER HEATER FLOOR DRAIN MECHANICAL FEES FINAL INSP. WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LUMBER GR. LAUNDRY TRAY AIR HANDLING UNIT CFM FRAMING SSL,%®� KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SQ. FT. ® c BATH TUB SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 11/4 c SEWAGE DISPOSAL SO.FT.GAR ® 3/4c HOUSE SEWER GAR. FIREWALL GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS d SEWER ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) / METER LOOP HEATING (FINAL) OTHER APP./EQUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ -$ LUMBER GR. p FINAL INSP. / FRAMING SSL,%®� FINAL INSP. ROOFING /� L / a /e%/�E / /��� �/ ,`AWOSi� " l/ REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING D MESH INSULATION/SOUND FINISH GRADING Z FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES/INITIALS GARDEN WALL FINAL DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated 619-775-3500 Date 9/22/94 1 Type of Permit I La Quinta No. 113082 Permit ,# Log #r Owner Name Sterling Homes No. 53170 Street Avenida Diaz City La Quinta Zip 92253 Study Area 112 APN # Tract # Lot # 0 Square Footage 11688 Type of Development Single Family Residence No. of units Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.65 x 1688 or $ 2,785.20 have been paid to D.S.U.S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Sterling Homes Telephone Name on the check . By Dolores A. Ballesteros Superintendent Fee collected /exempted by Vickie J. Durrett Signature r Payment Received Check No. 2270 Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting .SEP -19-94 TUE 3:47 PM STERLING RAYMARC FAX N0, 619 560 7173 P. 1 lYi/ +�vau :. aua.�ai FIOEUTY NATIONAL TITLE INS. CO. Order No, \� Escrow No. 9178 -LF Loan No. 010"WHEN RECORDED MAIL TO: e� oo IL )- x 8 $ a t d (q Ca SterlinqW.g Homes $ O P � < P.O. Box 450 16 V.4 La Quinta, CA 92253 W, SPACE ABOVE THIS LM FOR IMCORUFR'S USE MAIL TAX STATEMENTS TO: DOCUMENTARY TRANSrSR TAX 1...12..65•,•,•,,,,•...••...-. same as aboveCompumdan ionorvalueafprop"cvnveOR the amsidenvyed; ..K. Computed on the consideration of value less liens or encumbrances remaining 0 time of sale. Signanue of Declarant or Agan determining tmc—Firm Nate GRANT DEED APN 8774-042-010-5 FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, RUSTY RHODES. an unmarried man hereby GRANT(S) to STERLING HOMES. a General Partnership the real property in the City of La Qulnta- County of Riverside State of California, described as Lot 15 in Block 177 of Santa Carmelita at Bale La Quint&, Unit 818 as per map recorded in book 19, -page 31 of Mape.,.Reeords of Riverside County, California. lam-/ V February 22, 1994 } STATE OF CALEF91JMA )ss• COUNTY OF ///C.I,Z.[i�fs I on ag 47 st /9 �:i/ beforl'me, . 4-,4iNE Al personally eppeared 0 69 personally knovm to me vAdmee) to be d+e permt(s) whose neme(s) is/= suburilmd to the within L. LAIplE.F10A' P imtrumemt Md acknou4edged to me that h awcuted the same Comm. COM22 sous wsuc in hisA WN%eit sudWti* c hislheshheir sign& nrvEkSliis C0luttry u() tures) on iast t &a p (s) or ty upon bel"of which W Comm EaproO mm s. loan+ the pens ; Ecol m qi- SS h 1q1 seal: , " I\,— ('(his Brea for Olficioi moferiel sesn MAIL TAX STATEMENTS AS DIRECTED AB0V F. A %-k EARTH SYSTEMS CONSULTANTS S.C. Zwi!-/ BUENA ENGINEERS DIV. 79-811 B Country Club Drive Bermuda Dunes, CA 92201 • (619) 345-1588 Client Client Client Phone DATE - JOB NO. PROJECT S 9-/70 Ape • �)/ A a ELEVATION LOCATION FIELD TESTING- CONTRACTOR OWNER saN� g ��4s WEATHER TEMP. o at AM C at PM PRESENT AT SITE OPTIMUM MOISTURE CONTENT % 1 V-&� R rte,,, r- PC, TEST NUMBER TEST LOCATION LOT NO, ELEVATION FIELD TESTING- REFERENCE CURVE MOISTURE CONTENT % DRY DENSITY IbsJCu. ft. MAXIMUM DRY DENSITY % MAXIMUM DRY DENSITY IbsJcu.ft. OPTIMUM MOISTURE CONTENT % 1 V-&� R rte,,, r- PC, 9-0 �pNT REMARKS: FSgp �s D /t -/CL 2 aa1E �i9� O1 - G ,vAe. S .F kJ,dS LO .5O 1::2AD !-iia 41d .s 0 )jAc,-,v ONT�r�l. CLIENT REPRESENTATIVE SIGNATURE FIELD REPORT TECHNICIANS SIGNATURE Carole Christensen, Analyst Title -24 Energy Calculations ENERGY CALCULATIONS FOR: Sterling Homes P.O. Box 450 La Quinta, CA 92253 PROJECT: PLAN MJG-1 Front Door Facing West 1688 sq.ft. Custom Home La Quinta, CA Standard Proposed Compliance 47.09 45.60 + 1.49 Dual Aluminum Glazing, V. Blind; Phillips U -value or better Walls R-11 + V Falcon (R4.4); Roof R-38; Duct R-4.2 AFUE 78%; SEER 12.0,- One 2.0;One 40 gal gas water heater Table of Contents CF -IR MF -IR C -2R HVAC Sizing C -3R CF -6R to be posted and completed on site when equipment is installed 47-596 Lake Canyon Drive, Aguanga, CA 92536 79-733 Country Club Drive; Bermuda Dunes, CA 92201 1-800-735-8152 Member CABEC California Association of Building Energy Consultants TABLE OF CONTENTS TOC Project Title.......... Plan MJG-1 1688 Gas Date........ 05/26/94 Project Address........ La Quinta CA Documentation Author... Carole Christensen Building Permit Company ................ Carole Christensen, EA Telephone .............. 1-800-735-8152 Plan Check Da e Compliance Method...... MICROPAS4 by Enercomp, Inc. Field Check/ Date Climate Zone........... 15 MICROPAS4 v4.02 File-STERMJGI Wth-CTZ15S92 Program -TOC User#-MP1017. User -Carole Christensen, EA Run-Phi1Vb78.AC12.Rllflcn38.4 TABLE OF CONTENTS Report Page FORM CF -1R ................ 1 FORM MF -1R ................ 4 FORM C -2R ............:.... 6 FORM C -3R ................. 10 HVAC SIZING....., ........ 13 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... Plan MJG-1 1688 Gas Date........ 05/26/94 Project Address........ Documentation Author... Company................ Telephone.............. La Quinta CA Carole Christensen Carole Christensen, EA 1-800-735-8152 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 15 Building Perini Plan Check Date Field Check/ Date MICROPAS4 v4.02 File-STERMJGI Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen, EA Run-Phi1Vb78.AC12.Rllflcn38.4 GENERAL INFORMATION Conditioned Floor Area..... 1688 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 270 deg (W) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade (Package D) BUILDING SHELL INSULATION Component Insulation Assembly Type R -value U -Value Location/Comments Wall R-15 0.066 front, left, back, right Wall R-11 0.091 to garage Roof R-38 0.035 attic Door R-0 0.330 solid wood, to garage S1abEdge R-0 0.900 to outside S1abEdge R-0 0.720 to outside S1abEdge R-0 0.550 to garage/mech S1abEdge R-0 0.500 to garage FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Front (W) 15.8 1.040 1 Blinds.Lt None Yes None Door Front (W) 40.0 0.770 2 Blinds.Lt None Yes Wood Window Front (W) 12.0 0.610 2 Blinds.Lt None Yes Metal Window Front (W) 6.0 0.610 2 Blinds.Lt I; None Yes Metal Window Left (N) 25.0 0.820 2 Blinds.Lt None None Metal Window Left (N) 16.0 1.400 2 Drapes.Std None None Metal Window Left (N) 6.0 0.850 2 Blinds.Lt None None Metal Window Left (N) 16.0 0.620 1 None None None None Door Back (E) 53.3 0.780 2 Blinds.Lt None None Metal Window Left (N) 16.0 0.610 2 Blinds.Lt None None Metal Window Back (E) 20.0 0.820 2 Blinds.Lt None Yes Metal Window Back (E) 10.5 0.610 2 Blinds.Lt None None Metal Window Right (S) 20.0 0.820 2 Blinds.Lt None None Metal Window Right (S) 25.0 0.820 2 Blinds.Lt None None Metal Window Right (S) 15.8 1.040, 1 Blinds.Lt None None None CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... Plan MJG-1 1688 Gas Date........ 05/26/94 MICROPAS4 v4.02 File-STERMJGI Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 "User -Carole Christensen, EA Run-Phi1Vb78.AC12.Rllflcn38.4 FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Skylight Horz 3.4 0.800 2 none None None Metal THERMAL MASS Area Thickness Type Exposed (sf) (in) Location/Comments S1abOnGrade Yes 785 3.5 SlabOnGrade No 903 3.5 framing/cabinets InteriorHorz Yes 86 1.0 countertops InteriorVert Yes 22 1.0 shwer walls HVAC SYSTEMS Minimum Duct Duct Thermostat Equipment Type Efficiency Location R -value Type Gas 0.780 AFUE Attic R-4.2 Setback ACSplit 12.00 SEER Attic R-4.2 Setback WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value Storage Gas Standard 1 0.544 EF 40 R-12 SPECIAL FEATURES/REMARKS Phillips CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... Plan MJG-1 1688 Gas Date........ 05/26/94 MICROPAS4 v4.02 File-STERMJGI Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen, EA Run-Phi1Vb78.AC12.Rllflcn38.4 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple.orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... A.P. Lench, II, Company. Sterling Homes Address. P.O. Box 450 Lata, CA 92 Phone... (61 64-1866 License. #63 5 Signed.. AG Name.... Title... Agency.. Phone... President 3 �0� /C eta Signed.. (date) DOCUMENTATION AUTHOR Name.... Carole Christensen Company. Carole Christensen, EA Address. 47-596 Lake Canyon Dr. Aguanga, CA 92536 Phone... 1-800-735-8152 MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 4 MF -1R Project Title.......... Plan MJG-1 1688 Gas Date........ 05/26/94 Project Address........ La Quinta CA Documentation Author... Carole Christensen Company ................ Carole Christensen, EA Telephone .............. 1-800-735-8152 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 15 Building Permit Plan Check Da e Fie Check/ Date MICROPAS4 v4.02 File-STERMJGI Wth-CTZ15S92 Program -FORM MF-iR User#-MP1017 User -Carole Christensen, EA Run-Phi1Vb78.AC12.Rllflcn38.4 Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Design- Enforce- er ment *150(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturers labeled R -Value. *150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. 150(i): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets CEC quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ exfiltration controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label with certified U -value, and infiltration certification. c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed fp comply with Sec. 151 meets CEC quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and gas logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 5 MF -1R Project Title.......... Plan MJG-1 1688 Gas Date........ 05/26/94 MICROPAS4 v4.02 File-STERMJGI Wth-CTZ15S92 Program -FORM MF -1R User#-MP1017 User -Carole Christensen, EA Run-PhilVb78.AC12.Rllflcn38.4 SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Design- Enforce- er ment 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. 150(i): Setback thermostat on all applicable heating,systems. 150(j): Pipe and Tank insulation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. All buried or exposed piping insulated in recirculating sections of hot water system. 4. Cooling system piping below 55 degrees insulated. 5. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC sections 1002 and 1004; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System installed with: a. At least 36 inches pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa. 3. Pool system has directional inlets and a circulation pump time switch. 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously burning pilot light (Exception: Non -electrical cooking appliance with pilot < 150 Btu/hr.). LIGHTING MEASURES Design- Enforce- er ment 150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. COMPUTER METHOD SUMMARY Project Title.......... Plan MJG-1 1688 Gas Project Address........ Documentation Author... Company................ Telephone.............. La Quinta CA Carole Christensen Carole Christensen, 1-800-735-8152 EA i, Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 15 Page 6 C -2R Date........ 05/26/94 Building Permi Plan Check Da e Fi e Check/ Da e MICROPAS4 v4.02 File-STERMJGI Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen, EA Run-Phi1Vb78.AC12.Rllflcn38.4 MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 2.50 2.11 0.39 Space Cooling.......... 31.45 30.58 0.87 Water Heating.......... 13.14 12.91 0.23 Total 47.09 45.60 1.49 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area ............. Ground Floor Area.......... Slab -On -Grade Area......... Glazing Percentage......... Average Ceiling Height..... 1688 sf Single Family Detached New Front Facing 270 deg (W) 1 1 ReducedYear Slab On Grade 1 15203 cf 1688 sf 1688 sf 1688 sf 17.8 %lof FA 9 ft (Package D) COMPUTER METHOD SUMMARY Page 7 C -2R Project Title.......... Plan MJG-1 1688 Gas Date........ 05/26/94 MICROPAS4 v4.02 File-STERMJGI Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen, EA Run-Phi1Vb78.AC12.Rllflcn38.4 1. BUILDING ZONE INFORMATION Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Zone Type (sf) (cf) Units itioned Type (ft) (sf) HOUSE Residence 1688 15203 1.00 Yes Setback 2.0 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments HOUSE 1 Wall 119 0.066 R-15 270 90 Yes W.1IFALCON front 2 Wall 351 0.066 R-15 0 90 Yes W.1IFALCON left 3 Wall 314 0.066 R-15 90 90 Yes W.1IFALCON back 4 Wall 424 0.066 R-15 180 90 Yes W.1IFALCON right 5 Wall 253 0.091 R-11 270 90 No W.11.GARAGE to garage 6 Roof 1685 0.035 R-38 0 0 Yes R.38.2X4.24A attic 7 Door 20 0.330 R-0 270 90 Yes None solid wood -8 Door 17 0.330 R-0 270 90 No None to garage PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments HOUSE 9 SlabEdge 35 0.900 R-0 No to outside 10 SlabEdge 115 0.720 R-0 No to outside 11 SlabEdge 25 0.550 R-0 No to garage/mech 12 SlabEdge 2 0.500 R-0 No to garage FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt only Shade Description HOUSE 1 Window 15.8 1 None Fixed 1.040 271,,90 1.04 0.58 Blinds.Lt 2 Door 40.0 2 Wood Hinged 0.770 270 90 0.88 0.58 Blinds.Lt 3 Window 12.0 2 Metal Fixed 0.610 270 90 0.88 0.58 Blinds.Lt 4 Window 6.0 2 Metal Fixed 0.610 270 90 0.88 0.58 Blinds.Lt 5 Window 25.0 2 Metal Slider 0.820 0 90 0.88 0.58 Blinds.Lt 6 Window 16.0 2 Metal Fixed 1.400 0 90 0.88 0.78 Drapes.Std 7 Window 6.0 2 Metal Slider 0.850 0 90 0.88 0.58 Blinds.Lt 8 Window 16.0 1 None Fixed 0.620 0 90 0.62 0.62 None 9 -Door 53.3 2 Metal Slider 0.780 90 90 0.88 0.58 Blinds.Lt 10 Window 16.0 2 Metal Fixed 0.610 0 90 0.88 0.58 Blinds.Lt 11 Window 20.0 2 Metal Slider 0.820 90 90 0.88 0.58 Blinds.Lt 12 Window 10.5 2 Metal Fixed 0.610 90 90 0.88 0.58 Blinds.Lt COMPUTER METHOD SUMMARY Page 8 C -2R Project Title.......... Plan MJG-1 1688 Gas Date........ 05/26/94 MICROPAS4 v4.02 File-STERMJGI Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen, EA Run-Phi1Vb78.AC12.Rllflcn38.4 FENESTRATION SURFACES OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - # of Vent Surface (sf) Hght SC SC Interior Area Pan- Frame Open U- Act 6.8 Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description 13 Window 20.0 2 Metal Slider 0.820 180 90 0.88 0.58 Blinds.Lt 14 Window 25.0 2 Metal Slider 0.820 180 90 0.88 0.58 Blinds.Lt 15 Window 15.8 1 None Fixed 1.040 180 90 1.04 0.58 Blinds.Lt 16 Skylight 3.4 2 Metal Slider 0.800 270 0 0.88 0.88 none OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 1 Window 15.8 4.5 4.0° 11.5 1.5 10.0 0 10.0 5.0 3.0 0 0 0 2 Door 40.0 6.8 6.0 11.5 3.5 0 6.0 0 5.0 6.0 0 0 0 3 Window 12.0 2.0 6.0 11.5 0 0 6.0 0 5.0 6.0 0 0 0 4 Window 6.0 2.0 3.0 6.0 0 0 14.0 0 20.0 1.0 0 0 0 it Window 20.0 6.8 6.0 0 0 0 0 0 0 0 2.0 5.5 4.0 THERMAL MASS Area Thick Heat Conduct- Surface Mass Type (sf) (in) Cap ivity R -value Location/Comments HOUSE 1 S1abOnGrade 785 3.5 28.0 0.98 R-0.0 2 S1abOnGrade 903 3.5 28.0 0.98 R-2.0 framing/cabinets 3 InteriorHorz 86 1.0 24.0 0:67 R-0.0 countertops 4 InteriorVert 22 .1.0 24.0 0.67 R-0.0 shwer walls HVAC SYSTEMS Minimum Duct Duct Duct System Type Efficiency Location R -value Efficiency HOUSE Gas 0.780 AFUE Attic R-4.2 0.830 ACSplit 12.00 SEER Attic I, R-4.2 0.810 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value 1 Storage Gas Standard 1 0.544 40 R-12 COMPUTER METHOD SUMMARY Page 9 C -2R Project Title.......... Plan MJ6-1 1688 Gas Date........ 05/26/94 MICROPAS4 v4.02 File-STERMJGI Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen, EA. Run-Phi1Vb78.AC12.Rllflcn38.4 SPECIAL FEATURES/REMARKS Phillips CONSTRUCTION ASSEMBLY Page 10 3R Project Title.......... Plan MJG-1 1688 Gas Date........ 05/26/94 MICROPAS4 v4.02 File-STERMJGI Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen, EA Run-Phi1Vb78.AC12.Rllflcn38.4 Reference Name . W.1IFALCON Description .... Wall R-11+Falcon 2x4 16oc Type ........... Wall R -Value........ 15 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 16 inches on center Fraction ..... 0.15 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Total Unadjusted R -Values FRAMING ADJUSTMENT CALCULATION. ' Cavity U -Value: (1 / 16.94 x 0.85) + (1 / Framing Cavity R -Value Material 0.17 0.17 Name Description O. FILM.EX Exterior air film: winter value 1. STUCCO.0.88 0.875 in stucco 2. FALCONBD 1.0 1.00 3. BLDG.PAPER Building paper (felt) 4c. BATT.R11 R-11 batt insul (cavity = 3.5 in) 4f. FIR.2X4 2x4 in fir framing 5. GYP.0.50 0.50 in gypsum or plaster board I. FILM.IN.WLL Inside air film: heat sideways Total Unadjusted R -Values FRAMING ADJUSTMENT CALCULATION. ' Cavity U -Value: (1 / 16.94 x 0.85) + (1 / Framing Cavity R -Value Frame R -Value 0.17 0.17 0.17 0.17 4.40 4.40 0.06 0.06 11.00 -- -- 3.46 0.45 0.45 0.68 0.68 16.94 9.40 Total 9.40 x 0.L5) = 0.066 Btuh/sf-F Total R -Value: 1 / 0.066 = 15.12 sf-F/Btuh CONSTRUCTION ASSEMBLY Page 11 3R Project Title.......... Plan MJG-1 1688 Gas Date........ 05/26/94 MICROPAS4 v4.02 File-STERMJGI Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen, EA Run-Phi1Vb78.AC12.Rllflcn38.4 Reference Name . W.11.GARAGE Description .... Wall R-11 2x4 24oc Type ........... Wall R -Value ........ 11 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 24 inches on center Fraction ..... 0.12 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name Description R -Value R -Value b. FILM.EX Exterior air film: winter value 0.17 0.17 1. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 2. BLDG.PAPER Building paper (felt) 0.06 .0.06 3c. BATT.R11 R-11 batt insul (cavity = 3.5 in) 11.00 -- 3f. FIR.2X4 2x4 in fir framing -- 3.46 4. GYP.0.50 0..50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 Total Unadjusted R -Values 12.81 5.27 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 / 12.81 x 0.88) + (1 / 5.27 x 0.12) = 0.091 Btuh/sf-F Total R -Value: 1 / O.OI1 = 10.94 sf-F/Btuh CONSTRUCTION ASSEMBLY Page 12 3R Project Title.......... Plan MJG-1 1688 Gas Date........ 05/26/94 MICROPAS4 v4.02 File-STERMJGI Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen, EA Run-Phi1Vb78.AC12.Rllflcn38.4 Reference Name . R.38.2X4.24A Description .... Roof R-38 2x4 24oc Type ........... Roof R -Value ........ 38 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 24 inches on center Fraction ..... 0.07 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Total R -Value: 1 / 0.035 = 28.36 sf-F/Btuh Material Cavity Frame Name Description R -Value R -Value 0. FILM.EX Exterior air film: winter value 0.17 0.17 1. SHNGL.CEMENT Asphault-cement shingles 0.21 0.21 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3. PLY.0.50 0.50 in plywood 0.62 0.62 4c. AIR:RF.3.50 3.5 in & greater air space: heat flow up 0.80 -- 4f. FIR.2X4 2x4 in fir framing -- 3.46 5c. BATT.R38.0 R-38 batt insul (cavity > 11.25 in). 38.00 -- 6. GYP.0.50 0.50 in gypsum or plaster -board 0.45 0.45 I. FILM.IN.RF Inside air film: heat flow straight up 0.61 0.61 Total Unadjusted R -Values 40.92 5.58 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 / 40.92 x 0.93) + (1 / 5.58 x 0.6,7) = 0.035 Btuh/sf-F Total R -Value: 1 / 0.035 = 28.36 sf-F/Btuh HVAC SIZING Page 13 HVAC Project Title.......... Plan MJG-1 1688 Gas Date........ 05/26/94 Project Address........ Documentation Author... Company................ Telephone.............. La Quinta CA Carole Christensen Carole Christensen, EA 1-800-735-8152 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 15 Building Permi Plan Check Da e Field Check/ Date MICROPAS4 v4.02 File-STERMJGI Wth-CTZ15S92 Program -HVAC SIZING User#-MP1017 User -Carole Christensen, EA Run-Phi1Vb78.AC12.Rllflcn38.4 GENERAL INFORMATION Floor Area ................. Volume.. ............ Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange ............... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 1688 sf 15203 cf Front Facing INDIO n/a 33.7 degrees 29 F 5313 70 F n/a 112 F Ducts............................ 78 F 3431 30 F No No No 0.20 HEATING AND COOLING LOAD SUMMARY Heating Description (Btuh) 270 deg (W) Cooling (Btuh) Opaque Conduction and Solar...... 12452 6659 Glazing Conduction ............... 10096 8372 Glazing Solar .................... n/a 11419 Infiltration.......... ......... 8965 5313 Internal Gain .................... n/a 2550 Ducts............................ 3151 3431 Sensible Load .................... 34664 37744 LatentLoad ...................... n/a Minimum Total Load,�664 7549 45293 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing., availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. INSTALLATION CERTIFICATE CF -6R Use of this form to satiety the requirements of the Administrative Code In optional, but the Information must be provided and posted. Site Address Permit Number An installation certificate Is required to be posted at the building site prior to the issuance of the occupancy permit; this form may be used to meet these requirements. All appliance categories listed below are the actual equipment installed. Note that the efficiency and type of the appliance Installed must be equivalent or better than the appliance specified on the certificate of compliance (Form CF -1 R). This certificate (or its equivalent) shall be prepared and signed by the person(s) assuming overall responsibility for the appliance installation. Refer to the reverse side of this certificate for an explanation of information required. I, the undersigned, verify that the equipment listed in the category above my signature is the actual equipment installed and that the equipment meets or exceeds the requirements of the Appliance Efficiency Standards. In addition; I have verified that the equipment is equivalent to or more efficient than the equipment specified on the Certificate of Compliance submitted to demonstrate compliance with the Energy Efficiency Standards for residential buildings., HVAC SYSTEMS: Heating Equipment Heating Equip. CEC Certified Actual Distribution Duct or Heating Load Heating Type (Packaged Manuf. Make & Efficiency Type and Piping Before Over- Equipment heat Qurnl2. etcl Model Number (AFUF. etc.) L Lalbn R-Vaiue Sizing tuh) Capacity (Btuhl Cooling Equipment Cooling Equipment Actual Type (Packaged CEC Certified Compressor Unit Efficiency Duct Duct heat pump. etcl Manuf. Make &Model Number ISE1=fll LQcat1Qo_ B-AALL Signature, Date WATER HEATING SYSTEMS Distrib. Water CEC Certified Energy Tank System Heater Manuf. Make & Factor/ Volume Iy" Tyge/# Model # Ejir.__ (gallons) HVAC Subcontractor (Co. Name) OR General Contractor OR Owner Insul Internal Pilot Rated Solar/ Wrap Insul. Standby Light Input • Wood fl � Loss (%) (Btuh) kW/Btu Credits FAUCETS & SHOWER HEADS: All faucets and showerheads installed are listed in the Commissions Directory Of Certified Faucets And Showerheads, pursuant to Title -24, Part 6, Subchapter 2, Section 111. Signature, Data Plumbing Subcontractor (Co. Name) OR General Contractor OR Owner Revised December 1992 URBINA & ASSOCIATES 6370 anvil lake ave. san dieso, calitornla 92119 4 PLANNING & ARCHITECTURE 6 9 3 1 6 Dec. 23, 1994 6 Sterling Homes P.O. Box 450 La Quinta, Calif. 92253 re: Alternate Simpson Hardware Gentlemen, ,,, ,P,er�yqur; request, the framing hardwarespecified for Models '. MJG=1 , and' -C-1 has' beeni reviewed, -and "-may,-be installed as follows. For the MJG-1 model the post base at the Dining (Room/Garage may be substituted with_— at��Magson 'M`1"T -2s0'. For the C-1 model the truss hanger called out as "THA -22" may be substituted with a Simpson "HU -3516". Please feel free to call if you have any questions. R pectfull , � Xavier D. Urbina, Jr. Architect