06-0474 (SPIN)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
Property Address:
APN:
Application description:
Property Zoning:
Application valuation:
Applicant:
06-00000474
53-50-1 AVENIDA'tlDIAZ
774-111-013-1 -000000-
SPECIAL INSPECTION
COVE RESIDENTIAL
0
Architect or Engineer:
LICENSED CONTRACTOR'S DECLARATION
BUILDING & SAFETY DEPARTMENT -
BUILDING PERMIT
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: License No.:
Date: Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
an applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
( 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his of her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.)..
1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractors) licensed
pursuant to the Contractors' State License Law.). '
(_ 1 I am exempt under Sec. , B.&P.C. for this reason
Date: l "' 3
— CONSTRUCTION LENDING AGENCY
I hereby.affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
Owner:
GUILBAULT LOUIS ROLAND
53-501 AVENIDA DIAZ
LA QUINTA, CA 92253
(
FLDContracto
JAN 312M
CITYOF I:AqI TA
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 1/30/06
-----------------------------------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
_ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier - - - - - - - - - - - - - - - - - - - - - -- Policy Number
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
,(�
3�700 of the Labor Code, I shall forthwith comply with those provisions.
D2U
at_ r7� kpplicant -
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for *180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter upon the above-mentioned_pcoperty_for_inspection purposes.
'Date:%�3���k6ignatura (Applicant or,Agent) ».
Application Number . . . . . 06-00000474
y Permit . . . . . . SPECIAL INSPECTION
-- Additional desc
-
.. Permit Fee . . . . 100.00
Plan Check
Fee
.00
Issue Date
Valuation
. . .
.
_ Expiration Date 7/29/06
.0
Qty Unit Charge Per
Extension
BASE FEE
100.00
----------------------------------------------------------------------------
Special Notes and Comments
SPECIAL INSPECTION TO EVALUATE IMPACT
TO LIGHT & VENTILATION PRIOR TO PERMIT
FOR DOOR OR WINDOW CHANGEOUTS.
Fee summary Charged Paid
-------------------
Credited
Due
--------------------
Permit Fee Total 100.00
----------
.00
----------
.00
100.00
Plan Check Total .00
.00
00
.00
Grand Total 100.00
.00
.00
100.00
LQPERMIT
r - t'
ciei .
oF coPY
',Y�
P.O. Box 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
January 31, 2006
BUILDING & SAFETY DEPARTMENT
Special Inspection Report
RE: 53-501 Avenida Diaz, Permit #06-0474
(760) 777-7012
FAX (760) 777-7011
APN: 774-111-013
On January 31, 2006 at approximately 3:30 PM the following field observations were noted with
Code Compliance Officer Moises Rodarte accompanying me to investigate the conditions of a
pre-existing non conforming dwelling structure during the review of a proposed residential living
room and deck addition permit. Addition permit #05-5577 is reported by Mr. Louis Guilbault,
owner, submitted for plan review back check.
Riverside County Metro Scan (attached) reports the. structure of 1800 sqft constructed in 1973.
No County records are on file for the main structure. County of Riverside Building & Safety
Permit #221571 is on file for the 840 square foot detached garage. The detached garage was
constructed and approved by the County encroaching into the rear yard set back with zero feet
clearance between the neighboring property, a pre-existing non -conformity.
City of La Quinta Pool Permit #06-0261 was obtained on 1/30/06 without the identification of an
existing septic system. With no permit and/or records on file for this property verifying the
dwelling connected to the Coachella Valley Water Districts sewer system, it is highly
recommended prior to the excavation of the pool to hire the professional services of a contractor
to located the existing septic system to avoid an interruption of private services, public nuisance
and added expense to the owner. Verification of the existing septic system will be required prior
to the issuance of the proposed residential addition to ensure it is not located between the existing
detached garage and dwelling. This may be an additional correction for the plan review in
progress and will be forwarded to the Plan Reviewer performing the project review.
A 6080 sliding glass door was observed at the second floor bedroom opening onto an unprotected
roof. Mr. Guilbault stated he constructed the door approximately four years ago. The un -
permitted door opens on to a roof that; 1) has no guard rail protection, California Building Code
509.1 and 2) has not been designed for the uniform and concentrated live and dead loads
associated with it's proposed use, California Building Code Table 16-A. The door as observed is
not permitted and requires the immediate attention of the owner. Please secure the door from any
further use and submit evidence in the plan review in progress and/or by separate application with
required information to approve and permit the door as constructed.
The following electrical life safety conditions exist and require the immediate attention of the
owner;
Rear yard light switch and receptacle require damp location protection with GFI
protection.
Rear yard fluorescent lighting fxture.is not approved for exterior out door use as
installed.
• Exterior 220 dryer niche receptacle requires damp location protection.
vt.
Exterior 220 water heater receptacle requires damp location protection. Reconcile water
heater location with dwelling addition plan review in progress. .
Exterior patio abandon light fixture requires electrical wires exposed to terminate in the
wall with a damp location cover plate.
Abandoned spa sub -panel requires removal or maintenance and repair to remain in place.
The sub -panel shall be rated for exterior use with no openings in the dead front and
securely constructed to the structure. Spa equipment shall be properly wired with no
exposed romex wiring or removed.
A shed structure constructed on the south east corner at the master bedroom is not approved to
encroach into the five foot side yard set back or neighboring property. Please remove the sheet
metal structure. Additionally, for your safety, please ensure the gated enclosure out side the
master bedroom sliding glass door is operational for emergency escape egress. California
Building Code 310.4.
The north court yard wrought iron fencing has been removed and the owner constructed sliding
glass and french doors. The framing and doors are un -permitted and are required to be removed.
In summary, La Quinta Municipal Code violations and electrical safety violations exist on this
property. The residential addition permit under review requires the coordination of the above
noted conditions prior to the approval and issuance of a Building Permit #05-5577. Mr. Louis
Guilbault was very cooperative and demonstrated his great desire to improve his property. With
the understanding that some of the conditions noted above will be addressed with the construction
of the new addition the above noted conditions require the attention and remediation by the owner
should the addition permit not be issued. A re -inspection is required to close this case. For any
questions please contact me directly at (760) 777-7027.
Wan
ctfull
/Cr
Building Inspector II
cc Moises Rodarte, Code Compliance Officer
Kirk Kirkland, Senior Building Inspector
Anthony Moreno, Senior Code Compliance Officer
Greg Butler, Building & Safety Manager
*---------------------------
MetroScan / Riverside
---------------- -----------*
Parcel
:774 111 013 Pos
Int
Ref APN
:000 000
000
Owner
:Guilbault Louis R
Land
:$47,691
CoOwner
Struct
:$95,383
Site
:53501 Avenida Diaz La
Quinta 92253
Other
Mail
:53860 Avenida Herrera
La Quinta Ca 92253
Total
:$143,074
Xfered
:05/16/2002
Doc # :259630
Exempt
Price
x:$135,000 Full
Deed :Grant Deed
Type
LoanAmt
:$128,250
Loan :Conventional
% Imprvd
:67
Lender
:First Choice Mortgag
IntTyp:Adjustable
% Owned
:100
VestTyp
:Sole And Separ
Tax Area
:20-015
Use
:RO1 Res,Single Family
Residences
05-06Tax
:$1,723.12
Plat
:19
Map Grid
:879 E2
Census
:Tract:451.09 Block:l
OwnerPh
S:
T: R: Q:
TenantPh
.
..........
Bedrms
.............
:3 Stories :2
..........
Acres
:..11
...............
Year Built
:1973
BthFull
:1 Fireplace:No
LotSgFt
:4,791
Street
Type
:Paved
Bth3Qtr
:1 Pool :No
Bldg SF
:1,800
Waterfront
BthHalf
RmAddtns :Yes
AddOnSF
Gas Service
:None
Cnt1Ht
:Yes AddPkgTyp:
GarSgFt
:900
Water
Source
:Developed
CntlA/C
:Yes Roof Type:Tile
GarType
:Detached Sewer
Type .
:None
AgriPreserve
Information compiled from various sources. Real Estate Solutions makes no representations