Loading...
12-0896 (MECH)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T-iht 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: MICHAEL BROWN. 54900 AVENIDA DIAZ LA QUINTA, CA 92253 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 9/12 Application Number: 12=M_0 0896 Property Address: 54900 E IDA DIAZ APN: 774-291-008-17 -000000- Application description: MECHANICAL Property Zoning: COVE RESIDENTIAL Application valuation: 6500 T-iht 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: MICHAEL BROWN. 54900 AVENIDA DIAZ LA QUINTA, CA 92253 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 9/12 Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: \ Lender's Address: r+ LQPERMIT of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. .. I certify that I have read this application and state that the above inf orrect. I agree to comply with all city and county ordinances and state laws relating to building c , and h eby authorize representatives of this nt enter upon the above-mentioned property ec te: - , nature (Applicant or Agent): Contractor: Applicant: Architect or Engineer: BEST IN THE WEST 255 N. EL CIELO, 140-125 PALM SPRINGS, CA 92262 (760)343-1002 LiC. No.: 826714 -------------------------------------------------------------------------------------------- UCI SED CO TOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am Iiiprovisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business anro i als Code, and my License is in full force and effect. I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: C20 -C38 'cen� a No.: 826714 _ for by Section 3700 of the Labor Code, for the performance of the work for which this permit is Data:ntractor: issued. 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor • Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I a empt-from the Contractor's State License Law for the Carrier GUARD INS GRP Policy Number BEWC337354 following reason (Sec. 7031.5. Business and Professions Code: Any city or county that requires a permit to I certify that, in the performance of the o which This permit is issued, I shall not employ -any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the _ person in any manner so as to be to the workers' compensation laws of California, permit to file_a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, i�Ishou'd bec ect to th workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by 3700 of the Labode, I h mpl with those provisions. any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: Date: � pplicant: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and . the structure is not intended or offered for sale (Sec. 7044, Business avid Professions Code: The WARNING: FAILURE TO SECURE WORKERS' CO -ION COVERAGE IS UNLAWFUL, AND SHALL ' Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees; provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT (_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1 . Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_) I am exempt under Sec. , B.&P.C. for this reason - the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: \ Lender's Address: r+ LQPERMIT of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. .. I certify that I have read this application and state that the above inf orrect. I agree to comply with all city and county ordinances and state laws relating to building c , and h eby authorize representatives of this nt enter upon the above-mentioned property ec te: - , nature (Applicant or Agent): Application Number . . . . . 12-00000896 Permit MECHANICAL Additional desc . . Permit Fee . . . . 40.50 Plan Check Fee . Issue Date . . Valuation . . . . Expiration Date . . 2/05/13 10.13 0 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 16.50 -------------------------------------------------------------------7-7------ Special Notes and Comments HVAC CHANGE -OUT: INSTALL NEW 3 TON HEAT PUMP FAU & CONDENSER. 2010 CODES. ---------------------------------------------------------------------------- Other Fees . . . . . . . BLDG STDS ADMIN.(SB1473) 1:00 Fee summary Charged Paid Credited Due ---------------=----------------------------------------- Permit Fee Total 40.50 .00 .00 40.50 Plan Check Total 10.13 .00 .00. 10.13 Other Fee Total 1.00 ,00 .00 1.00 Grand Total 51.63 .00 .00 51.63 LQPERMIT Simplified Prescriptive Certificate of Compliance: 2008 Residential HVACAlterations CF-lR-ALT-HVAC Climate Zones 10 - 15 Site Address: Enforcement Agency: Date: Permit #: 54900 Avenida Diaz La Quinta, CA 92253 City of La Quinta Aug 4, 2012 Dud insulation Conditioned Floor Equipment Typel List Minimum Efficiency2 requirement Area Thermostat ❑ Package Unit 0 Furnace ❑ Indoor Coil ❑ AFUE 2 SEER 13.0 0 COPE3 ® HSPF 7.7 R 6 (CZ 10-13) Served by system 8 Setback If not already present, must be (3 Condensing Unit ❑ EER ❑ Resistance ❑ R 8 (CZ 14-I5) 1200 sf installed) ❑ Other 1. Equipment Type: Choose the equipment being installed; if more than one system, use another CF -IR -ALT -HVAC for each system. 2. Minimum Equipment Efficiencies: 13 SEER, 78% AFUE, 7.7HSPF for typical residential systems. HERS VERIFICATION SUMMARY Listed below are FOUR HVAC alteration Options. The installer decides what work is being done and picks one of the appropriate Options. Each Option lists the HERS measures that must be conducted. A copy of the forms shall be left on site for final inspection and a copy given to the homeowner. At final, the inspector verifies that the work listed on this form was in fad the work completed by the installer- The inspector also verifies that each appropriate CF -611 and registered CF -4R forms (no hand filled CF-4Rs allowed) are filled out and signed.Beginning October 1, 2010, a registered copy of the CF -111 and CF -611 shall also be on site for final inspection. m 1. HVAC Changeout Required Forms: . All HVAC Equipment CF -6R forms: MECH-04, MECH-2I-HERS and (for split systems) MECH-25-HERS replaced CF -411 forms: MECH-21 and (for split systems) MECH-25 . Condenser Coil and /or . Indoor Coil and /or CF -611 forms: MECH-04, MECH-2I-HERS and (for split systems) MECH-25-HERS . Furnace CF -411 forms: MECH-21 and (for split systems) MECH-25 For Split Systems: Duct leakage < 15 percent; RC, CCA <_ 300 CFM/ton (Minimum Air Flow Requirement), TMAH Exempted from duct leakage testing if: ❑ 1. Duct system was documented to have been previously sealed and confirmed through HERS verification, or ❑ 2, Duct systems with less than 40 linear feet in unconditioned space, or ❑ 3. Existing duct systems are constructed, insulated or sealed with asbestos ❑ 4, The system will not be Ducted (ie. Ductless Mini -Split System) (Also Exempt from Refrigerant Charge) ❑ 2. Now HVAC System Required Forms: . Cut in or Changeout with new ducts: (all new CF -6R forms: MECH-04, MECH-20-HERS; and (for split systems) MECH-22-HERS, and ducting and all new MECH-25-HERS CF -4R forms: MECH-20, and (for split systems) MECH-22, and MECH-25 equipment) For Split Systems: Duct leakage < b percent; RC, CCA ? 35D CFM/ton, FIND, TMAH, SIMS, and either HSPP or PSPP. For Packaged Units: Duct leakage < 6 percent ❑ 3. New Ducts with/or without Required Forms: Replacement . Includes replacing or installing all new ducting and/or outdoor condensing unit CF -611 forms: MECH-04, MECH-20-HERS, and (for split systems) MECH-25-HERS and/or indoor coil and/or furnace. No or some CF -411 forms: MECH-20 and (for split systems) MECH-25 equipment changed. For Split Systems: Duct leakage < 6 percent; RC, CCA -2 300 CF141ton, Ti AH For Packaged Units: Duct leakage < 6 percent ❑ 4. New Ducting over 40 fleet Required Forms: . Includes adding or replacing more than 40 CF -611 forms: MECH-04, MECH-2I-HERS linear feet of duct in unconditioned space. CF -4R forms: MECH-21 For split system or packaged units: Duct leakage < 15 percent ❑ EXCEPTION: Existing duct systems constructed, insulated or sealed with asbestos. Contractor (Documentation Author's /Responsible Designer's Declaration Statement) • I certify that this Certificate of Compliance documentation is accurate and complete. • I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the design identified on this Certificate of Compliance. • I certify that the energy features and performance specifications for the design identified on this Certificate of Compliance conform to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations. • The design features Identified on this Certificate of Compliance are consistent with the intormation documented on other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with the permit application. Name: Richard C Weaver Sr Signature: Richard C Weaver Sr Company: BEST IN THE WEST AIR CONDITIONING & HEATING INC Date: Aug 4, 2012 Address: 255 N ELCIELO ROAD #140-125 License: 967982 City/State/Zip: PALM SPRINGS / CA / 92262 Phone: (760) 343-1002 Reg: 212-A0042129A-00000000-0000 2008 Residential Compliance Forms Registration Date/Time: 2012/08/04 14:13:42 HERS Provider: CalCERTS, Inc. July 2010 r, s Bin # City of La Quinta Building & Safety Division P.O. Box 1504, 78-495 Calle Tampico. La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # n � ��- Project Address: Owner's Name: 7 66,�C) A. P. Number. Address: 6- v *,s—;- Legal Description: City, ST, Zip; �3 Contractor.�S 141e, Telephone! Project Description: Address: ;2S'5;4J, gL City, ST, Zip: l 4� p Telephone:• C) 3 —/OOZ State Lie. # Arch., Engr., Designer: City Lie. #: Address: City, ST, Zip: Telephone: State Lie. #: Name of Contact Person: Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ft.: #Stories: # Units: Telephone # of Contact Person:, Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING . PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan V Review, ready for correctionsrrssue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for cor•rectionstissue Developer Impact Fee Planning Approval Called Contact Person A.LP.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees