Loading...
0103-115 (SFD)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date 652186 1 /2 Date �� �� Signature of Contractor /•^''�- ^'"' OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section , B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATIOI I DECLARATION I hereby affirm under penalty of perjury one of the following declarations: () I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. (0 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code,•for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier Policy No. (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of Californig,-an� agree that if _1_should become subject to the workers' compensation;provisions of Section 700 of the Labor Code, I shall forthwith comply with those provision - Date:!/ 2 - o2 i Applicant— Warning: pplicant Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application.. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorizerepresentatives pf this City to enter upon the above-mentioned property for'inspect�n purP9ses. Signature (Owner/Agent) �_� ' Date` - BUILDING PERMIT PERMIT DATE VALUATION 311 :1 TRACT LOT €5 1.0-• q 152rIg� /� .�q0 1 \l JOB SITE APN ADDRESS -: M% AVlf"I�D A t IAZ OWNER CONTRACTOR /DESIGNER / EN INEER PAULDI N 1"1Y.z!e1+ 8 DFAWN WC. P.NiLDE-14 EV_Q4S p:3ErisON IMI. P.(?. BOX. (1711 1'.01. BOX 621 k2,%MJ' IDE CA 92501 IUVEWyik E CA 92503. C160)399• 141'3 MIA 6246 USE OF PERMIT MtGJ_YAWLiy 5.yt vTG s�t� . TDE;T�.t�i r �a�.�� ��`� txacl..us�a✓ �1�='a 1�.�.;.,IPI�t:2f../S)��° :" Q 0 --.nn APF 2 ''PACT C ONSTFtIXTION L1511.0 3F e. eARAG�t�>�RPORT (SF) 8,349.6r jJ CITY OF LA OUINTA FI ANCE DEPT N'EWfa°�1fAMW COST 010 CE317S V=.0N CO NS'I'1' UCTI.ON PIIvta 1 e11 i):10n414 -tT0 3 MUD F'L �y:la C;•$MIX FEE 101-000-4 9-31 S $556.06 FEE 1' EP031'1' 101-000-439.'"!18 4210100 MMCHAHICAL FM,,' 101-000-421-000 " UTZf) 0 9UXT,P.ICA.14 FEE 101-000.420.000 $113.62 1'1.:UMBYH0 PES -E 101-000-419-000 $113.25 ;3 t'.13tYNG MOTION :t1U - REBID 101.000•14.1.000 $0.62 i;R.��..�1N4� �:� I OY ••0�-q,2 �-0€30 f�2f).s�0 01vFdi-a PER IMPACT M. �;,la{t7,tt7 �i'•:120n^�.1��� � �1 ••coo -4d 1-:�� �Igf3.;10 SUPI,-TOTAL CONSI1; U(MON'M111 LAUCHEM` 83,452.53 L103 PRE•3'A1D'E E= 4250,00 TOTAL FIM1 Iff FallS M -Tel 14(71TV t3t?,0265 RECEIPT DATEBAY`, 4W DATE FINALED INSPECTOR t a- , C' 5 INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs ` Underground Ducts Forms & Footings _ �a Ducts Slab Grade �� Return Air Steel Roof Deck O 1 Combustion Air Exhaust Fans . O.K. to Wrap F.A.U. Framing ¢ Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath;EIC _ n Drywall - Int. Lath 195, t 7 Final.. Final POOLS - SPAS BLOCKWALL APPROVALS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping A .c9 PLUMBING APPROVALS Gas Test Electric Final Waste Lines_ Heater Final . Water Piping ' _ t Plumbing Final Plumbing. Top Out _ Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral_ Sewer Connection f (_6b Pool Cover Encapsulation _g � Gas Piping Gas Appliances Final COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole 0 Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles -'Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) O li �Isqk 164T Notice: Document Cannot Be Duplicated Date 4/2/01 No. 21826 Desert Sands Unified School District 47-950 Dune Palms Road La Quinta, CA 92253 760-771-8515 CERTIFICATE OF COMPLIANCE owner NamePaulden Evans Design Inc. No. 54-925 Street Avenida Diaz APN # 774-266-021 Jurisdiction La Quinta Permit # 0103-115 Log # City La Quinta Zip 92253 Study Area Tract # Type of Development Comments Lot # 10 Square Footage 1617 Single Family Residence No. of Units 1 At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 2.05 X 1,617 or $ 3,314.85 the property listed above and that building 1 .J permits and/or Certificates of Occupancy for this square footage in this proposed project may now'be issued Fees Paid By OC/ El Paseo Bank - Paulden Evans Teleplsone Name on the check _ r � By Dr. Doris Wilson %; f Superintendent Fee collected /exempted by Annette Barlow Payment Received $3,314.85 Check No. 023678936 Signature 4wvti NOTICE: Pursuant of Assembly Bill 3081 (CHAP 549, STATS. 1998) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to collect them on the District('s)(s') behalf, whichever is earlier. Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting oto3-� j 4.9 2& Building Address LOT 10. At Owner 4 P.O. BOX 1504 78-495 CALLE TAMPICO DIAZ LA QUINTA, CALIFORNIA 92253 Mailing I Address P 0 BOX 621 City lZip ITel. PAULDEN EVANS City Zip Tel. RIVERSIDE 925017 909 788-6780 State Lic. City & Classif. 652188 8 HI C Lia # Arch., Engr., Designer Address Tel. CityI Zip I State Lic. # LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER•BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its Issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). 1! 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I 1 I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) t? I am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby r� pagf�fir�matptqhpat 1 have a certificate of consent to self -insure, or a certificate of Worker's C/ OO J / O Irlsyr�nce, or a c@rtyf Aed'oopy ShP,(Qo�Sec. 3800, Labor Code:) - Policy No. C 77Company S G M r7 Copy is filed with the city. q Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be Completed it the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. - Date Owner i NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this ptermit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is'subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above- mentioned property for inspection purposes. Signature of a0plicant Date Mailing Address City, State, Zip �(ea-se seems old .s�� APPLICATI'0Mf ONLY BUILDING: TYPE'CONST. A0.0 OCC. GRP. A.P. Number 0714—PAA-091-7 _ 1A nf17krA rA Q7?; o Boanck 216 �ab Santa Cwm, eti 0iat VaCe LaQuin Project D §cri�t�'lorpeA map nec bk 19, pgb 50=51 Obi /napb SINGLE FAIItILY HOME as 0103 - It ti3- ILAa -Vi r-> _ _ f_.. 4 Sq. Ft.No. No. Dw. Size 1 s 617 Stories 1 Units New !4 Add ❑ Alter ❑ Repair ❑ Demolition ❑ imated Valuation PERMIT ) AMOUNT Plan Chk. Dep. -SSC., - r- C Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure `. TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: WHITE = FINANCE YELLOW= APPLICANT PINK = BUILDING DIVISION HEC:C)i3IJIM REOUEBTED BY FIDELITY NAT TITLE CO iiECORDING REQUESTED BY: Fidelity National Title Company Escrow No. 41606 -CB Title Order No. 00541259 When Recorded Mail Document and Tax Statement; To: Mr. Paulden Evans' P.O. Box 621 i Riverside, CA 92502 DOC " 2000-277347 07/38/2000 08:00A Fee:8.00 Page 1 of 1 Doc T Tax Paid Recorded in Official Records County of Riverside Gary L. Orso Asses9or, County Clerk d Recorder I IIII III III IIII III III III II III III I II IIII I II I I I Fm s U PACE SIZE DA PCOR NOCOR SMF MISC. Tv A I R L COPY LONG REFUND NCHG FXAM GRANT DEED The undersigned grantorls) declare(s) Documentary transfer tax is $33.00 ( X 1 computed on full value of property conveyed, or [ 1 computed on full value less value of liens or encumbrances remaining at time of sale, ( 1 Unincorporated Area City of La Quinta FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Admin► L.L.C., a Delaware Limited Liability Corporation WA–t IA- 0VdVL\i 1,1 I u - U, (1, hereby GRANT(S) to Paulden Evans Design & Development, Inc., a California Corporation the following described real property in the City of La Quinta County of Riversidel! State of California: Lot 10, Block 276, Santa Carmelita at Vale La Quinta, Unit #25, County of Riverside, State of California, as per map recorded in Book 19, Page 50-51 of Maps, in the Office of the County Recorder of said County. DATED: June 5, 2000 STATE OF CALIFORNIA COUNTY OF ON Co 113 10Qbefore me, e ere personally appeared personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed. the same in his/her/thei, authorized capacity(ies), and that Admim L.L.C., a Delaware Ltd. L.C., a Ltd. Liability Co. t By:Ze, -KA- bI"t& D1&—lock) by his/her/their signature(s) on the instrument the. d, person(s), or the entity upon behalf of which the HACKIE FERRp r person(s) acted, executed the instrument. Q* ' 'Mmission # !162609f - (K +62609r'(K Notaryry Public ..;aiiforrna;V ;`i 3AN DIEGO vunty N Witness my hand and official sea ;; I ,, ur=ExpresN,,. ,tw, Signature L'�1 Yny Comm. J�i�£S /vov.lOil 'god MAIL TAX STATEMENTS AS DIRECTED ABOVE FD -213 (Rev 7/96) GRANT DEED f' RC DISTRICT - PLANNING REVIEW FORM This form is to be used by CDD staff for review of single family dwellings in the RC (Cove Residential) District, in order to determine the applicability of compatibility issues or need to require the filing of Master Design Guidelines by the applicant. It shall be transmitted to the Building and Safety Department as your correction list. Please attach additional explanations as necessary. APPLICANT Paulden Evans SITE ADDRESS 54-925 Avenida Diaz APNBIN NO.: �!J CASENO.: 2001-396 LEGAL: LOT [ p BLOCK Dn (D UNIT S.C.@V.L.Q. CHECKED BY: Stan Sawa DATE: Inform the assigned Building plan checker upon your assignment to this case. The CDD Executive Secretary maintains a log book to track applications and assign case numbers. REQUIRED ITEM Y . N COMMENT/CORRECTION Compatibility Review �l Case logged and number assigned �I Verify legal and APN information Consistent with MDG on file (as.applicable MDG filing required (5 filings since 9/3/98) Consistency with street/surrounding area: Colors Materials Architecture ' Other -Requirements: cwt At *'Certificate. of Occupancy City of La' Quinta Building and Safety Department This Certificate issued pursuant to the requirements of Section 109 of the Uniform Building Code, certifying that, at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: BUILDING ADDRESS: Use Classification: SFD Occupancy Group: R 3 54-925 AVENIDA DIAZ Bldg. Permit No.: 0103-115 Type of Construction: VN Land Use Zone: RC Owner of Building: PAULDEN EVANS DESIGN INC. —i-;�. Building Official Address: P.O. BOX 621 City: RIVERSIDE, CA 92501 By: STEVE TRAXEL Date: 06-13-01 POST IN A CONSPICUOUS PLACE KEN WILKINSON CITY OF LA QUINTA BUILDING DEPARTMENT COLTON,CA STRUCTURAL ENGINEER 6956 INDIANA AVE. SUITE #9 RIVERSIDE, CA. 92506 VOICE (909) 682-2001 FAX (909) 682-2014 E-MAIL kenwilk@airl.net February 14, 2001 Attention: RESIDENTIAL PLAN CHECKING Re: PAULDEN EVANS — 54- 925 AVENITA DIAZ — LA QUINTA Subject: DEFERRED SUBMITTALS FOR TRUSS CALCS PER CBC SECT. 106.3.4.2 To whom it may concern: I have reviewed the submittal documents for the roof trusses and have found them to be in general conformance with the design of the building. Yours tr 1 , e Ln ='nson StruEngineer �/�pFESSlp\ ani �e1'9! No. 1944 r Exp. 9-3a srgRucNRPOP�,�P OFC M. t �t� (5�.ti�►lta u5 I.o,vt��� 319 M�uvs 59-Z, 3 PAWL (SAtw ?A Nus g� l , Past 15AT.r1 . P1aT,,(2A�, 4t (.4f VgcP' -D'. $� �Q • FT ►��v�,� V�w��ttPc('to+� �4'�.' 431 see K. LJt"OowS`-occ;?-S . I-tG4f 1 vtiA io zo fx D 40-30 Xa Ao 1 o ® 501cp Fx Ilso Fx 8 ZS o tq t� fx• a50�� Fe- 33.� 33 • `i TITLE 24 REPORT Title 24 Report for: PAULDEN EVANS 54-925 AVENIDA DIAZ LA QUINTA, CA Project Designer: PAULDEN EVANS Report Prepared By: GINA BROWN RIVERSIDE ENGINEERING 3600 Lime Street Bldg. 1, #117 Riverside, CA 92501 (909) 369-17.00 '. Job Number: ITY OF D ING & S 6077paulden APPC . f FOR CONS) F Date: DATE d 2/26/01 brf` ce The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 1998 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 2.1 By EnergySoft Job Number: 6077paulden User Number: 1160 S TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary HVAC System Heating and Cooling Loads Summary 1 2 3 6 7 11 EnergyPro 2.1 By Energysoft Job Number: 6077paulden User Number: 1160 Certificate of Comaliance: Residential (Part 1 of 2) CF -1 R PAULDEN EVANS 2/26/01 Project Title Date LOT 1 CALLE COLIMA & LOT 10 AVENTA DIAZ LA nt"A'Wess Building Permit # RIVERSIDE ENGINEERING (909) 369-1700 Plan Check Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1,617 ft2 Total Conditioned Slab Area: 1,617 f? Building Type: (check one or more) ® Single Family Detached (SFD) ❑ Addition Alone ❑ Single Family Attached (SFA) ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (South) 180 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation R-21 Wall (W.21.2x6.16) Wood 0.059 Exterior Wall R-38 Roof (R.38.)(14.16) Wood 0.028 Exterior Roof FENESTRATION Shadinq Devices Type Orientation Area I Labeled Fenestration Interior Exterior — Overhang Side Fins SF U -Value SHGC roller blind etc. shadescreen etc. Yes/No Yes / No Front (South) 118.6 0.72 0.70 Drapery Bug Screen ❑ X❑ ❑ X❑ Left (West) 14.0 0.72 0.70 Drapery Bug Screen ❑ X❑ ❑ X❑ Rear (North) 49.0 0.72 0.70 Drapery Bug Screen ❑ X❑ ❑ X❑ Right (East) 12.0 0.72 0.70 Drapery Bug Screen ❑ -1 ❑ X❑ ❑ ❑ 11 11 ❑ ❑ ❑ ❑ - El ❑❑ -- Fl 1:1 F1 1111 1111 El El 1111 _ ❑ ❑ ❑ ❑ El El El Run Initiation Time: 02/26/0111:18:48 Run Code: 983216128 Ener Pro 2.1 By Ener Soft User Number: 1160 Job Number: 6077 aulden Pa e:3 of 11 Certificate of Compliance: Residential (Part 2 of 2) CI, PAULDEN EVANS 2/26/01 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Fcrnnr.P 78°% AFUE Ducts in Attic 42 Setback HVAC System Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location/ heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 10.0 SEER Ducts in Attic 42 Rathark HVAC System WATER HEATING SYSTEMS Water Heater Water Heater Distribution Rated 1 # in Input Tank Cap. Energy Fact! 1 External or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value Standard Gas 50 gal or Less Small Gas Standard 9- 40 000 s0_ 053 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Name: Title/Firm: PAULDEN EVAN Address: Documentation Author Name: GINA BROWN Title/Firm: RIVERSIDE ENGINEERING Address: 3600 Lime Street Bldcl. 1, #117 Riverside, CA 92501 Teleph ;Teliepho s 369- 00 Lic. # (signature) (date) sgnature (date) Enforcement Agency Name: Title/Firm: _ Address: Telephone_ IEneravPro 2.1 By EneravSoft User Number: 1160 Job Number: 6077paulden Paae:4 of 11 1 Certificate of Compliance: Residential (Addendum) CF -1 R PAULDEN EVANS 2/26/01 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )asea on ine aaequacy or ine special jusurication ano oocumeniation sunmiiieo. IPlan Field The DHW System "Standard Gas 50 qal or Less" Enerqv Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field Run Initiation Time: 02/26/01 11:18:48 Run Code: 983215128 EnergyPro 2.1 By EnergySofl User Number: 1160 Job Number: 6077paulden Page:5 of 11 Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component specifications. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMEN Building Envelope Measures '§ 150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. § 150(b): Loose fill insulation manufacturer's labeled R -value. a'§ 150(c): Minimum R-13 wall insulation in framed walls or equivalent U -value (does not apply to exterior mass walls). '§ 150(d): Minimum R-13 raised floor insulation in wood framed floors. § 150(1): Slab edge insulation - water absorption rate < 0.3%, water vapor transmission rate < 2.0 perm/inch. ❑X §118: Insulation specified or installed meets quality standards. Indicate type and form. o§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfillration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Manufactured fenestration products labeled with certified U -value, SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. §1500: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ® §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures FX—] §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. a§1500): Pipe and Tank Insulation 1, Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation, piping between heat source and tank insulated. 3,Insulation on the first 5' of pipes closest to water heater tank, non -recirculating systems (R-4 or greater), buried or exposed piping in recirculating sections of hot water systems, cooling system piping below 55 deg F. a'§150(m): Ducts and Fans 1. All ducts and plenums constructed, installed, insulated, fastened, and sealed to comply with the ICBO 1997 UMC sections 601603; ducts insulated to a minimum installed R-4.2 or ducts enclosed entirely within conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct closure system that meets the applicable requirements of UL181, UL181S, or UL181B and other applicable specified test for longevity given in 150(m). 2, Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems servng conditioned space have either automatic or readily accessible, manually operated dampers. X❑ §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no.pilot or electric resistance heating. 2. System is installed with at least 36" of pipe between filter and heater, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. X] §115: Central Furnaces, pool heaters, spa heaters or household cooking appliances have no constant pilot light. Lighting Measures §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. 150(k)2: Rooms with a shower or bathtub must either have at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in 150(k)2.; and recessed ceiling are IC (insulation cover) approved. EnergyPro 2.1 By EnergySofi User Number: 1160 Job Number: 6077paulden Page:6 of 11 Computer Method Summary (Part 1 of 3) C -2R PAI LDEN EVAN,S Project Title 2/26/01 Date I OT 1 CAI IF COLIMA & LpT 10 AVFNTA DIA7 I A QI IINTA Project Address Building Permit # RI ERSpF FNGINEERING (909) 369-1700 Documentation Author Telephone PlanChecklDate Computer Performance Compliance Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 6.00 4.18 1.82 Space Cooling 46.58 48.16 -1.58 Domestic Hot Water 14.97 14.83 0.15 Totals 67.55 67.17 0.38 GENERAL INFORMATION Conditioned Floor Area: 1,617 Floor Construction Type: X❑ Slab Floor Building Type: Single Fam Detached Raised Floor Building Front Orientation: (South) 180 deg Number of Dwelling Units: 1.00 Total Conditioned Volume: 16,170 Number of Stories: 1 Slab Floor Area: 1,617 BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units Thermostat Vent Zone Type Type Hgt. Area ConditinnPd SPthark n/a Solar OPAQUE SURFACES Act. Gains Type Area U -Val. Azm. Tilt Y / N Form 3 Reference Location / Comments Com uter Method Summary (Part 2 of 3) C -2R PAULDEN EVANS 2/26/01 Project Title Date FENESTRATION SURFACES LI -Value Act. Glazing Type Location/ # Type _L_ Window Front (South) 2 Window Left (Westi 3 Window Rear (North) 4 Window Right (East) Area SHGC Azm. Tilt Comments 118.6 0 720 070 180 q0 Double Mtl Uncoated Default 1st Floor 14.0 0.720 0.70 270 90 Double Mtl Uncoated Default 1st Floor 49.0 0.720 0.70 0 90 Double Mtl Uncoated Default 1st Floor 12.0 0.720 0.70 90 90 Double Mtl Uncoated Default 1st Floor INTERIOR AND EXTERIOR SHADING # Interior Shade Type SHGC_ E 1 Drapery 0.68 Bug Screen 0.76 2 DraperV 0.68 Bug Screen 0.76 T Drapery 0.68 Bug Screen 0.76 4 Drapery 0.68 Bug Screen 0.76 Window Fin 2.1 Rv Fncrnv.0nft User Number: 1160 Job Number: 6077paulden Page:8 of 11 Computer Method Summary (Part 3 of 3) C -2R PAULDEN EVANS 2/26/01 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 166 0.76 0.0 0 1st Floor Slab Perimeter 135 0_76 0.0 0 1st Floor HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location/ pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 78%AFUE Ducts in Attic 4.2 Setback HVAC System Pipe Hydronic Piping Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location/ heat pump, evap. cooling) (SEER) (attic; etc) R -Value Type Comments Split Air Conditioner 10.0 SEER Ducts in Attic 4.2 Setback HVAC System WATER HEATING SYSTEMS Rated/ Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution • # in Input Cap. or Recovery Standby R -Value System Name Type Type Svst. (Btu/hr) (aal) Efficiencv Loss (%) Ext. Standard Gas 50 gal or Less Small Gas Standard —1 40,000 50 0.53 n/a 12 1 For small gas storage (rated input — 75000'Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btulhr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 02/26/0111:18:48 Run Code: 983215128 EnergyPro 2.1 By EnergySoft User Number: 1160 Job Number: 6077paulden Page:9 of 11 Computer Method Summary (Addendum) 22-R PAULDEN EVANS 2/26/01 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )area on the aaequacy of the special jusutication ana aocumemation suomitted. I Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. me mERS rater must document the tieia ventication and diagnostic testing of tnese measures on a torm GI --5K. Plan Field Run Initiation Time: 02/26/01 11:18:48 Run Code: 983215128 EnergyPro 2.1 By EnergySoft User Number: 1160 Job Number: 6077paulden Page:10 of 11 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE PAULDEN EVANS 2/26/01 SYSTEM NAME FLOOR AREA HVAC System 1,617_ Number of Systems 1 Heating System Output per System 89,000 Total Output (Btuh) 89,000 Output (Btuh/sqft) 55.0 Cooling System Output per System 46,000 Total Output (Btuh) 46,000 Total Output (Tons) 3.8 Total Output (Btuh/sqft) 28.4 Total Output (sgft/Ton) 421.8 Air System CFM per System 1,575 Airflow (cfm) 1,575 Airflow (cfm/sqft) 0.97 Airflow (cfm/Ton) 410.9 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions EA 26.0 OF O Outside 0 cfm 68.9 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensiblel Latent I I CFM I Sensible 1,729 29,211 3,855 703 38,053 0 1,461 1,903 0 0 0 0 0 0 0 0 0 1,461 1,903 32,1321 3,8551 41 859 BDP CO. 561AJ048--• 29,530 12,795 89,000 Total Adjusted System Output 28,530 12,795 89,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 m Jan 12 am Kics (Airstream Temperatures at Time of Heatina Peak) 68.9 of m 121.60f Heating Coil :DOLING SYSTEM PSYCHROMETRICS 11.0/77.40F ow Outside Air 0 cfm 78.9/66.8 ° F Supply Fan 1575 cfm 121.6 of -� Supply Air Ducts 120.5 of ROOMS 70.0 of k Return Air Ducts 4 78.9/66.80F ® 61.4/60.30F Cooling Coil Supply Fan 1575 cfm 61.4 / 60.3 of Supply Air Ducts 62.2/60.6OF 55.3% R.H. ROOMS 78.0/66.6OF K Return Air Ducts `{ I EneravPro 2.1 By EneravSoft User Number: 1160 Job Number: 6077paulden Page:11 of 11 1 KEN WILKINSON STRUCTURAL ENGINEER 6956 INDIANA AVE. SUITE #9 RIVERSIDE, CA. 92506 VOICE (909) 682-2001 FAX (909) 682-2014 E-MAIL kenwilkinson@fam.net May 3, 2001 CITY OF LA QUINTA BUILDING & SAFETY DEPARTMENT Attention: BUILDING INSPECTIONS Re: PAULDEN EVANS RESIDENCES - LA QUINTA Subject:.SHEAR PANELS CHANGES. The shear panels as shown on the approved plans may be changes from the 7/16" thickness to the 3/8" APA rated wood structural.panels. The allowable shear values remain the same. Yours truly, QPOFESSIOA, ILKIry/ O Ken Wilkinson yam' 19�e� Structural Engineer •w 1 ..n o- { .•1r