10-1272 (RER)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: C10-00001272
Property Address: 50195 DORAL ST
APN: 770-080-001-1 -25389 -
Application description: REMODEL - RESIDENTIAL
Property Zoning: MEDIUM DENSITY RES
Application valuation: 6000
c&ht aF4w
Applicant: Architect or Engineer:
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class:B License No.: 591025
I L�/Z
CDate: lO Contractor:
4 -
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1 _) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
1 I I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
Owner:
HIMKA THEODORE/LAMKIN
Contractor:
CV ELITE BUILDERS INC
PO BOX 5686
LA QUINTA, CA 92253
_ (760)837-0079
Lic. No.: 591025
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 12/22/10
LORIANNE
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 238004121
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Cod , I shall forthwith comply with those provisions.
Date: ZZ /!/Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this count to ente7lr upon the above-mentioned property fo ' spection purposes.
Date: agnature (Applicant or Agek:.
Application Number . . . . . 10-00001272
------ Structure Information 70SF GARAGE CONVERSION/VB/RES-3 [CONV] -----
Other struct info . . . . . CODE EDITION 2007/2008
----------------------------------------------------------------------------
Permit .
. .. BUILDING PERMIT
Additional desc
.
Permit Fee . .
. . 81.00
Plan Check
Fee
52.65
Issue Date . .
. .
Valuation
. . . .
6000
Expiration Date
. . 6/20/11
Qty Unit
Charge Per
Extension
BASE
FEE
45.00
4.00
--------------- ----------------------------------------------------------
9.0000 THOU BLDG
2,001-25,000
36.00
Permit
ELECT - ADD/ALT/REM
Additional desc
.
Permit Fee . .
. . 17.45
Plan Check
Fee
4.36
Issue Date . .
. .
Valuation
0
Expiration Date
6/20/11
Qty Unit
Charge Per
Extension
BASE
FEE
15.00
70.00
----------------------------------------------------------------------------
.0350 ELEC
NEW RES
- 1 OR 2
FAMILY
2.45
Permit . . . .
. . MECHANICAL
Additional desc
. .
Permit Fee . .
. . 19.50
Plan Check
Fee
4.88
Issue Date . .
. .
Valuation
. . . .
0
Expiration Date
6/20/11
Qty Unit
Charge Per
Extension
BASE
FEE
15.00
1.00
------------------------------------------------------------------=---------
4.5000 EA MECH
VENT
INST/ DUCT ALT
4.50
Permit .
. . PLUMBING
Additional desc
.
Permit Fee . .
. . 28.50
Plan Check
Fee
7.13
Issue Date . .
. .
Valuation
. . . .
0
Expiration Date
6/20/11
Qty Unit
Charge Per
Extension
BASE
FEE
15.00
1.00
7.5000 EA PLB
WATER
HEATER/VENT
7..50
1.00
3.0000 EA PLB
WATER
INST/ALT/REP
3.00
LQPERMIT
LQPERMIT
Application Number .10-.00001272
Permit . . . . . . PLUMBING
Qty Unit Charge Per
Extension
1.00 3.0000 EA PLB GAS PIPE 1-4
OUTLETS
3.00•
----------------------------------------------------------------------------
Special Notes and Comments
70SF GARAGE CONVERSION/VB/RES-3/CLASS
A -FR [CONVENTIONAL] CONVERTING CART
PARKING IN GARAGE TO SITTING AREA FOR
EXISTING GUEST BEDROOM.- INCLUDES THE
RELOCATION OF EXISTING WATER HEATER.
2007/2008 CALIFORNIA BUILDING CODES.
December 22, 2010 7:46:07 AM AORTEGA
Other Fees . . . . . . . . . BLDG•STDS ADMIN
(SB1473)c-
1.00
ENERGY REVIEW
FEE
5.27
Fee summary Charged Paid
-----------------
Credited
Due
Permit Fee Total 146.45 .00
-----------
.00
146.45
-
Plan Check Total 69.02 .00
.00
69.02
Other Fee Total 6.27 .00
.00
6.27
Grand Total 221.74 .00
.00
221.74
LQPERMIT
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 80 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Brian Beavers Check No.
Name on the check Telephone
Funding Exempt
By Dr. Sharon P. McGehee
Superintendent
Fee collected /exempt d by Sharon McGi rey Payment Recd
'Over/Under .'
Signature / .
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will Vrve to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on YjVch the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public efftity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
'I1RClfl�n1 YAIilANI;E ASST `s
Avai
DA
PR tNY -A
VENT= NAhlwt(*T- iotkAmSi0---
k5 T*
7M a t . ll!r wi" 4t "Y"
iP
t Tuftlikikebtft. .6', aid w It,
..Sbokwwmn am twr-*.WAP go-lwl.c
rWd 0
9: to mbirrae�ahia-2,
arms8idnl
�eiirbipaKsrib:�.relcYlific.ti�'�a►: -.
-11—Waitumb . i*-kc6b64* sys eam iuprttl we. fi.fiC
>Z• ��4��pplssq'ia9ptmibidi>oiNQte+tyi+�4�eiva�Ic14'�ao019�td1+pN4dtc
AW* -A— Al
7) 7 !!!Z
Birt #
City of La Quinta
Building 8r Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Pemllt #
Project Address:
J 5 O
i- S
Owner's Name: L I,�'N_4J, ►t� T` � 11 (/�1
A. P. Number: ' I - OV-- 001 —
Address:
Legal Description:
City, ST, Zip:
Contractor: ; VS 1L
Telephone: -
Project Description: C O N V E -•T 1 N G �,#7
Address: 1q ��� nI �v�.I p IJ '� �, a
City, ST, Zip: LN Gm i Viv-C A ' 61-U�
I V�1 � �� T-
D
Telephone: ��Jf' -) S
'"'"r f
s ITT ) lV �p4�•o�
State Lie. # : _5 5cl i OLS City Lie. #:
Arch., Engr., Designer: D U A
Address:
City., ST, Zip: Li\ Qv o !T _C -A . qus3
Telephone: Lo -Construction
•#ry<• . �•+;��
Type: Occupancy:
Project type circle one): New Add'n Alter Repair Demo
State Lie. #•
Name of Contact Person: IV 0\Jv"
Sq. Ft.:
# Stories: #Units:
Telephone # of Contact Person:
Estimated Value of Project: o
APPLICANT: DO NOT WRITE BELOW THIS LINE
tt
Submittal
Req'd
Recd
TRACKING PERMIT FEES
Plan Sets
Plan Check submittedt Item
Amount
Structural Calcs.
Reviewed, ready for corrections (Z
!,� Plan Check Deposit
Truss Cates.
Called Contact PersonPlan
Check Balance
Tide 24 Calcs.
Plans picked up 1ti Construction
Flood plain plan
Plans resubmitted Mechanical
Grading plan
2•" Review, ready for correction su I Electrical
�; A"t
Subcontactor List
Called Contact Person Plumbing
w i
Grant Deed
Plans picked up S.M.I.
H.O.A. Approval
Plans resubmitted Grading
IN HOUSE:
''d Review, ready for correctionsfiissue Developer Impact Fee
^
Planning Approval
Called Contact Person .I-P.P.
Pub. Wks. Appr
Date of permit Issue
to,
School Fees
K
Total Permit Fees
z% I
12-1 7 JUW - CSN
We� 3
/.a/ 3
I �, C�tts.1►a 4a...eD
quit" WAu 6-7 "f w 111"6
a
N
BUILDING ENERGY ANALYSIS REPORT
�. PROJECT:
Lamkin-Himka Res. Addition
zk� 50195 Doral Street
La Quinta, CA 92253
Project Designer:
Dual Designs
760-771-3626
Report Prepared by:
Gina Rose-Starkey
EQS, Inc.
i 42335 Washington St. #F-330
Palm Desert, CA 92211
Ari=F7a_91a�
Date:
11/17/2010
The Ene'rgyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro5.1byEnergySoft User Number 5862 RunCode: 2010-11-17710:36:23 /D:
TABLE OF CONTENTS
Cover Page 1
Table -of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 9
HVAC System Heating and Cooling Loads Summary 12
EnergyPro 5.1 by EnergySok.. Job Number: ID: User Number: 5862 1
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Lamkin-Himka Res. Addition
Building Type m Single Family ❑ Addition Alone
❑ Multi Family la Existing+ Addition/Alteration 11111712010
Date
Project Address
50195 Doral Street La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,680
Addition
70
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
,❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity fiz) Features see Part 2 of 5 Status
Roof Wood Framed Attic R-38 2,610 Existing
Wall Wood Framed R-19 1,983 Existing
Slab Unheated Slab -on -Grade None 2,610 Perim = 266' Existing
Roof Wood Framed Attic R-38 70 New
Slab Unheated Slab -on -Grade None 70 Perim = 26' New
Wall Wood Framed R-21 64 New
Door Opaque Door None 20 Existing
Door Opaque Door None 24 Existing
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Right (NE) 145.0 0.870
0.70 none none Bug Screen Existing
Right (NE) 55.0 0.550
0.45 none none Bug Screen Existing
Front (SE) 70.0 0.870
0.70 none none Bug Screen Existing
Left (SM 48.0 0.870
0.70 none none Bug Screen Existing
Left (Vtq 8.0 0.550
0.45 none none Bug Screen Existing
Rear (NIM 80.0 0.870
0.70 none none Bug Screen Existing
Front (SE) 13.0 0.870
0.70 none none Bug Screen New
Left (SVtq 3.6 0.550
0.45 none none Bug Screen Existing
Left (M 102.0 0.870
0.70 none none Bug Screen Existing
Right (E) 20.0 0.870
0.70 none none Bug Screen Existing
Front (S) 28.0 0.870
0.70 none none Bug Screen Existing
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Fumace 80% AFUE
Split Air Conditioner 13.0 SEER Setback
Existing
1 Central Furnace 80% AFUE
Split Air Conditioner 13.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
Existing Sleeping Area Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
Existing Living Area Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
WATER HEATING
Qt . Type Gallons Min. Eff Distribution Status
Energ Pro 5.1 by Energ Soft User Number: 5862
RunCode: 2010-11-17T10:36:2 ID:
Page 3 of 13
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF-1 R
Project Name
Lamkin-Himka Res. Addition
Building Type m Single Family ❑ Addition Alone
❑ Multi Family 0 Existing+ Addition/Alteration
Date
11/17/2010
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The HVAC System Existing Sleeping Area must serve only Sleeping Areas. The non-closable area between zones cannot exceed 40 sf and each
zone must be controlled with a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA-6
HIGH MASS Design - Verify Thermal Mass: 225.0 It Exposed Slab Floor, 3.500" thick at Existing Sleeping Area
HIGH MASS Design - Verify Thermal Mass: 975.0 ft Covered Slab Floor, 3.500" thick at Existing Sleeping Area
HIGH MASS Design - Verify Thermal Mass: 70.0 ftz Covered Slab Floor, 3.500" thick at Addition
The HVAC System Existing Living Area must serve only Sleeping Areas. The non-closable area between zones cannot exceed 40 sf and each zone
must be controlled with a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA-6 must
HIGH MASS Design -Verify Thermal Mass: 1,410.0 ftz Exposed Slab Floor, 3.500" thick at Existing Living Area
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form for each of the measures listed below for final to be given.
EnerqWro 5.1 by EnemySoft User Number: 5862 RunCode: 2010-11-17T10:36:2 ID: Page 4 of.13
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF-1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Lamkin-Himka Res. Addition
❑ Multi Family m Existing+ Addition/Alteration
11/17/201
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2 r
Space Heating 13.75 11.79 1.96
Space Cooling 109.44 109.37 0.08
Fans 25.41 25.26 0.15
Domestic Hot Water 0.00 0.00 0.00
Pumps 0.00 0.00 0.00
Totals 148.60 146.42 2.18
Percent Better Than Standard: 1.5
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (SE) 135 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (SE) 552 111
Fuel Available at Site: Natural Gas (Svv) 896 162
Raised Floor Area: 0 (NM 328 80
Slab on Grade Area: 2,680 (NE) 888 220
Average Ceiling Height: 9.1 Roof 2,680 0
Fenestration Average U-Factor: 0.83 TOTAL: 573
Average SHGC: 0.67 Fenestration/CFA Ratio: 21.4%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company EQS, Inc. 0
0
Address 42335 Washington St. #F-330 Name Gina Rose-Starkey
Citotate/Zip Palm Desert, CA 92211 Phone 760-674-2345 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Dual Designs-
Address Name David Jackson P L16
City/State/Zip Phone 760-771-3626 Signed License # Date
EnerPro 5.1 by EnerqySoft User Number: 5862 RunCode: 2010-11-17T10:36:2 ID: Pa e 5 of 13
CERTIFICATE OF COMPLIANCE: Residential
Part 4 of 5 CF-1 R
Project Name
Lamkin-Himka Res. Addition
Building Type m Single Family ❑ Addition Alone
❑ Multi Family la Existing+ Addition/Alteration
Date
1/17/201
OPAQUE SURFACE DETAILS
Surface
T e Area
U- Insulation Joint Appendix
Factor CavityExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
1,200
0.026 R-38
0
0 Existing4.2.1-A9
ExistingSleeping Area
Wall
512
0.074 R-19
45
90 Existing4.3.1-A5
ExistingSleeping Area
Wall
150
0.074 R-19
135
90 Existin 4.3.1-A5
Existing Sleeping Area
Wall
80
0.074 R-19
225
90 Existing4.3.1-A5
ExistingSleeping Area
Wall
96
0.074 R-19
270
90 Existing4.3.1-A5
ExistingSleeping Area
Slab
225
0.730 None
0
180 Existing4.4.7-A 1
ExistingSleeping Area
Slab
975
0.730 None
0
180 Existing4.4.7-A1
ExistingSleeping Area
Wall
88
0.074 R-19
315
90 Existing4.3.1-A5
ExistingSleeping Area
Roof
70
0.026 R-38
0
0 New 4.2.1-A9
Addition
Slab
70
0.730 None
0
180 New 4.4.7-A1
Addition
Wall
64
0.069 R-21
45
90 New 4.3.1-A6
Addition
Wall
67
0.074 R-19
135
90 Existing 4.3.1-A5
Addition
Wall
64
0.074 R-19
225
90 Existing 4.3.1-A5
Addition
Roof
1,410
0.026 R-38
0
0 Existing 4.2.1-A9
Existing Living Area
Wall
22
0.074 R-19
45
90 Existing 4.3.1-A5
Existing Living Area
Wall
116
0.074 R-19
1351
90 1 Existing 4.3.1-A5
Existing Living Area
FENESTRATION SURFACE DETAILS
ID
Type
Area U-Factor
SHGC2
Azm Status
Glazing Type
Location/Comments
1
Window
24.0 0.870 NFRC
0.70 NFRC 45 Existing
Double Metal Clear
Existing Sleeping Area
2
Window
10.0 0.870 NFRC
0.70 NFRC 45 Existing
Double Metal Clear
Existing Sleeping Area
3
Window
25.0 0.550 NFRC
0.45 NFRC 45 Existing
Glass Block
Existing Sleeping Area
4
Window
15.0 0.870 NFRC
0.70 NFRC 45 Existing
Double Metal Clear
Existing Sleeping Area
5
Window
30.0 0.550 NFRC
0.45 NFRC 45 Existing
Glass Block
Existing Sleeping Area
6
Window
10.0 0.870 NFRC
0.70 NFRC 135 Existing
Double Metal Clear
Existing Sleeping Area
7
Window
48.0 0.870 NFRC
0.70 NFRC 225 Existing
Double Metal Clear
Existing Sleeping Area
8
Window
8.0 0.550 NFRC
0.45 NFRC 270 Existing
Glass Block
Existing Sleeping Area
9
Window
24.0 0.870 NFRC
0.70 NFRC 315 Existing
Double Metal Clear
Existing Sleeping Area
10
Window
56.0 0.870 NFRC
0.70 NFRC 315 Existing
Double Metal Clear
Existing Sleeping Area
11
Window
13.0 0.870 NFRC
0.70 NFRC 135 New
Double Metal Clear
Addition
12
Window
48.0 0.870 NFRC
0.70 NFRC 45 Existing
Double Metal Clear
Existing Living Area
13
Window
48.0 0.870 NFRC
0.70 NFRC 45 Existing
Double Metal Clear
Existing Living Area
14
Window
20.0 0.870 NFRC
0.70 NFRC 135 Existing
Double Metal Clear
Existing Living Area
15
Window
20.0 0.870 NFRC
0.70 NFRC 135 Existing
Double Metal Clear
Existing Living Area
16
Window
20.0 0.870 NFRC
0.70 NFRC 135 Existing
Double Metal Clear
Existing Living Area
(1) LI-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
-HqtT Wd
Ove hanq Left Fin
Len H t LExt RExt Dist Len
Ri ht Fin
H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
Bug Screen
0.76
EnergyPro
5.1 by EnergySoft User Number: 5862
RunCode: 2010-11-17T10:36:2 ID:
Page 6 of 13
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R
Project Name
Lamkin-Himka Res. Addition
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
11/17/201
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area I Factor Cavi!Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments
Door
201 1.450 None
135 90 Existing 4.5.1-A1
Existing Living Area
Door
241 1.450 None
135 90 Existing 4.5.1-A1
Existing Living Area
Wall
3861 0.074 R-19
225 90 Existing 4.3.1-A5
Existing Living Area
Wall
108 0.074 R-19
270 90 Existing 4.3.1-A5
Existing Living Area
Slab
1,410 0.730 None
0 180 Existing 4.4.7-A1
Existina Livinq Area
Wall
160 0.074 R-19
315 90 Existing 4.3.1-A5
Existing Living Area
Wall
70 0.074 R-19
90 90 Existing 4.3.1-A5
Existing Living Area
Wall
64 0.074 R-19
180 90 Existing 4.3.1-A5
Existing Living Area
FENESTRATION SURFACE DETAILS
ID
Type Area U -Factor SHGC2
Azm Status Glazing Type
Location/Comments
17
Window 1.8 0.550 NFRC 0.45 NFRC 225 Existing Glass Block
Existing Living Area
18
Window 1.8 0.550 NFRC 0.45 NFRC 225 Existing Glass Block
Existing Living Area
19
Window 12.0 0.870 NFRC 0.70 NFRC 270 Existing Double Metal Clear
Existing Living Area
20
window 48.0 0.870 NFRC 0.70 NFRC 270 Existing Double Metal Clear
Existing Living Area
21
Window 42.0 0.870 NFRC 0.70 NFRC 270 Existing Double Metal Clear
Existing Living Area
22
Window 20.0 0.870 NFRC 0.70 NFRC 90 Existing Double Metal Clear
Existing Living Area
23
Window 20.0 0.870 NFRC 0.70 NFRC 180 Existing Double Metal Clear
Existing Living Area
24
Window 8.0 0.870 NFRC 0.70 NFRC 180 Existing Double Metal Clear
Existing Living Area
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC H t Wd
Ove hanq Left Fin
Len H t LExt RExt Dist Len
Ri ht Fin
H t Dist Len H t
17
Bug Screen 0.76
18
Bug Screen 0.76
19
Bug Screen 0.76
20
Bug Screen 0.76
21
Bug Screen 0.76
22
Bug Screen 0.76
23
Bug Screen 0.76
24
Bug Screen 0.76
EnergyPro
5,1 by EnergySoft User Number: 5862
RunCode: 2010-11-17T10:36:2 ID:
Pae 7 of 13
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF -1 R
Project Name
Lamkin-Himka Res. Addition
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+Addition/Alteration
Date
911971209
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area ft
New Existing Altered Removed Volume Year Built
Existing Sleeping Area Existing Sleeping Area
1,200
9,600 1985
Addition
70
560
Existing Living Area Existing Living Area
1,410 1
14,100 1985
Totals 1 701 2,6101 0 0
HVAC SYSTEMS
S stem Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Existing Sleeping Area 1 Central Furnace
80% AFUE Split Air Conditioner 13.0 SEER Setback
Existing
Existing Living Area 1 Central Furnace
80% AFUE Split Air Conditioner 13.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
Existing Sleeping Area Ducted Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
Existing Living Area Ducted Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
RatedJCa
Input
Btuhor
Energy
Factor
RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
CEC Standard
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
.2 w
w a-
Hot Water Piping Length
n
o
v
Q —I
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty. HP
Plenum Outside Buried
❑
❑
❑
❑
❑
❑
EneMYPro 5.1 by EnemySoft User Number: 5862
RunCode: 2010-11-17T10:36:2 ID:
Page 8 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF -1 R
Project Name
Lamkin-Himka Res. Addition
Date
11111712010
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(')3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind.
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number: 5862 RunCode: 2010-11-17T10:36:23 /D: Page 9 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Lamkin-Himka Res. Addition
11111712010
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tae is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or. equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number: 5862 RunCode: 2010-11-17710:36:23 /D: Page 10 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Lamkin-Himka Res. Addition
11111712010
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with § 150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134 and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoff User Number. 5862 RunCode: 2010-11-17710:36:23 /D: Page 11 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Lamkin-Himka Res. Addition
Date
11/17/2010
System Name
Existing Sleeping Area
Floor Area
1,270
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING PEAK
CFM Sensible
Total Room Loads 1,719 27,929
Return Vented Lighting 0
Return Air Ducts 2,368
Return Fan 01
Ventilation 230 9,409
Supply Fan 0
Supply Air Ducts 2,368
TOTAL SYSTEM LOAD 42,075
COIL HTG.
Latent CFM
3,189 646
4,091 230
7,280
PEAK
Heating System
Sensible
Output per System 51,000
23,357
Total Output (Btuh) 51,000
Output Btuh/s ft 40.2
1,659
Cooling System
0
Output per System 36,000
10,531
Total Output (Btuh) 36,000
0
Total Output (Tons) 3.0
1,659
Total Output (Btuh/s ft) 28.3
Total Output s ft/Ton 423.3
37,207
Air System
CFM per System
1,200
HVAC EQUIPMENT SELECTION
Airflow cfm
1,200
Existing 3 ton
30,526
1,439
51,000
Airflow cfm/s ft 0.94
Airflow cfm/Ton
400.0
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
30,526
1,439 51,000
Aug 3 PM Jan 1 AM
Outside Air % 19.2%
Outside Air cfm/s ft 0.18
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 61 OF
Outside Air
230 cfm Supply Fan
1,200 cfm
69 OF
61 OF 105 OF
Heating Coil
104 OF
�
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 81/65°F 81/65°F 55/54°F
c
Outside AirAr
230 cfm Supply Fan Cooling Coil
1,200 cfm
74 162 OF
53.4%
57 / 54 OF
ROOM
72 / 61 OF
EnergyPro 5.1 by EnergySoft
User Number. 5862 RunCode: 2010-11-17710:36:23 /D:
Page 12 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Lamkin-Himka Res. Addition
Date
11/17/2010
System Name
Existing Living Area
Floor Area
1,410
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 2,006
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 115
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 79,000
33,692
2,564 738
26,979
Total Output (Btuh) 79,000
0
Output Btuh/s ft 56.0
2,857
1,917
Cooling System
0
0
Output per System 58,000
4,767
2,143 115
5,315
Total Output (Btuh) 58,000
0
4,707
0
Total Output (Tons) 4.8
2,857
1,917
Total Output (Btuh/s ft) 41.1
Total Output s ft/Ton 291.7
44,174
36,127
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Existing 5 ton 44,134
5,118
79,000
79,000
F Jan 1 AM
Airflow cfm/s ft 1.42
Airflow cfm/Ton 413.8
Outside Air % 5.8%
Total Adjusted System Output 44,134
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
5,118
Aug 3 PM
Outside Air cfm/s ft 0.08
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 67 OF
O
Outside Air
115 cfm Supply Fan
AL 2,000 cfm
69 OF
67 OF 105 IF
Heating Coil
4
_
104 OF
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 76/62°F 76/62°F 55/54°F
01 c -
Outside Air Ak-
115 cfm Supply Fan Cooling Coil 56 / 54 OF
2,000 cfm
52.4% ROOM
73 / 61 of 72 / 61 OF
EnergyPro 5.1 by EnergySoft
User Number: 5862 RunCode: 2010-11-17710:36:23 /D: