Loading...
10-1272 (RER)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: C10-00001272 Property Address: 50195 DORAL ST APN: 770-080-001-1 -25389 - Application description: REMODEL - RESIDENTIAL Property Zoning: MEDIUM DENSITY RES Application valuation: 6000 c&ht aF4w Applicant: Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class:B License No.: 591025 I L�/Z CDate: lO Contractor: 4 - OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 I I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: HIMKA THEODORE/LAMKIN Contractor: CV ELITE BUILDERS INC PO BOX 5686 LA QUINTA, CA 92253 _ (760)837-0079 Lic. No.: 591025 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 12/22/10 LORIANNE WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 238004121 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Cod , I shall forthwith comply with those provisions. Date: ZZ /!/Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this count to ente7lr upon the above-mentioned property fo ' spection purposes. Date: agnature (Applicant or Agek:. Application Number . . . . . 10-00001272 ------ Structure Information 70SF GARAGE CONVERSION/VB/RES-3 [CONV] ----- Other struct info . . . . . CODE EDITION 2007/2008 ---------------------------------------------------------------------------- Permit . . .. BUILDING PERMIT Additional desc . Permit Fee . . . . 81.00 Plan Check Fee 52.65 Issue Date . . . . Valuation . . . . 6000 Expiration Date . . 6/20/11 Qty Unit Charge Per Extension BASE FEE 45.00 4.00 --------------- ---------------------------------------------------------- 9.0000 THOU BLDG 2,001-25,000 36.00 Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 17.45 Plan Check Fee 4.36 Issue Date . . . . Valuation 0 Expiration Date 6/20/11 Qty Unit Charge Per Extension BASE FEE 15.00 70.00 ---------------------------------------------------------------------------- .0350 ELEC NEW RES - 1 OR 2 FAMILY 2.45 Permit . . . . . . MECHANICAL Additional desc . . Permit Fee . . . . 19.50 Plan Check Fee 4.88 Issue Date . . . . Valuation . . . . 0 Expiration Date 6/20/11 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 ------------------------------------------------------------------=--------- 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 28.50 Plan Check Fee 7.13 Issue Date . . . . Valuation . . . . 0 Expiration Date 6/20/11 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7..50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 LQPERMIT LQPERMIT Application Number .10-.00001272 Permit . . . . . . PLUMBING Qty Unit Charge Per Extension 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00• ---------------------------------------------------------------------------- Special Notes and Comments 70SF GARAGE CONVERSION/VB/RES-3/CLASS A -FR [CONVENTIONAL] CONVERTING CART PARKING IN GARAGE TO SITTING AREA FOR EXISTING GUEST BEDROOM.- INCLUDES THE RELOCATION OF EXISTING WATER HEATER. 2007/2008 CALIFORNIA BUILDING CODES. December 22, 2010 7:46:07 AM AORTEGA Other Fees . . . . . . . . . BLDG•STDS ADMIN (SB1473)c- 1.00 ENERGY REVIEW FEE 5.27 Fee summary Charged Paid ----------------- Credited Due Permit Fee Total 146.45 .00 ----------- .00 146.45 - Plan Check Total 69.02 .00 .00 69.02 Other Fee Total 6.27 .00 .00 6.27 Grand Total 221.74 .00 .00 221.74 LQPERMIT Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 80 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Brian Beavers Check No. Name on the check Telephone Funding Exempt By Dr. Sharon P. McGehee Superintendent Fee collected /exempt d by Sharon McGi rey Payment Recd 'Over/Under .' Signature / . NOTICE: Pursuant to Government Code Section 66020(d)(1), this will Vrve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on YjVch the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public efftity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting 'I1RClfl�n1 YAIilANI;E ASST `s Avai DA PR tNY -A VENT= NAhlwt(*T- iotkAmSi0--- k5 T* 7M a t . ll!r wi" 4t "Y" iP t Tuftlikikebtft. .6', aid w It, ..Sbokwwmn am twr-*.WAP go-lwl.c rWd 0 9: to mbirrae�ahia-2, arms8idnl �eiirbipaKsrib:�.relcYlific.ti�'�a►: -. -11—Waitumb . i*-kc6b64* sys eam iuprttl we. fi.fiC >Z• ��4��pplssq'ia9ptmibidi>oiNQte+tyi+�4�eiva�Ic14'�ao019�td1+pN4dtc AW* -A— Al 7) 7 !!!Z Birt # City of La Quinta Building 8r Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Pemllt # Project Address: J 5 O i- S Owner's Name: L I,�'N_4J, ►t� T` � 11 (/�1 A. P. Number: ' I - OV-- 001 — Address: Legal Description: City, ST, Zip: Contractor: ; VS 1L Telephone: - Project Description: C O N V E -•T 1 N G �,#7 Address: 1q ��� nI �v�.I p IJ '� �, a City, ST, Zip: LN Gm i Viv-C A ' 61-U� I V�1 � �� T- D Telephone: ��Jf' -) S '"'"r f s ITT ) lV �p4�•o� State Lie. # : _5 5cl i OLS City Lie. #: Arch., Engr., Designer: D U A Address: City., ST, Zip: Li\ Qv o !T _C -A . qus3 Telephone: Lo -Construction •#ry<• . �•+;�� Type: Occupancy: Project type circle one): New Add'n Alter Repair Demo State Lie. #• Name of Contact Person: IV 0\Jv" Sq. Ft.: # Stories: #Units: Telephone # of Contact Person: Estimated Value of Project: o APPLICANT: DO NOT WRITE BELOW THIS LINE tt Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submittedt Item Amount Structural Calcs. Reviewed, ready for corrections (Z !,� Plan Check Deposit Truss Cates. Called Contact PersonPlan Check Balance Tide 24 Calcs. Plans picked up 1ti Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2•" Review, ready for correction su I Electrical �; A"t Subcontactor List Called Contact Person Plumbing w i Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE: ''d Review, ready for correctionsfiissue Developer Impact Fee ^ Planning Approval Called Contact Person .I-P.P. Pub. Wks. Appr Date of permit Issue to, School Fees K Total Permit Fees z% I 12-1 7 JUW - CSN We� 3 /.a/ 3 I �, C�tts.1►a 4a...eD quit" WAu 6-7 "f w 111"6 a N BUILDING ENERGY ANALYSIS REPORT �. PROJECT: Lamkin-Himka Res. Addition zk� 50195 Doral Street La Quinta, CA 92253 Project Designer: Dual Designs 760-771-3626 Report Prepared by: Gina Rose-Starkey EQS, Inc. i 42335 Washington St. #F-330 Palm Desert, CA 92211 Ari=F7a_91a� Date: 11/17/2010 The Ene'rgyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro5.1byEnergySoft User Number 5862 RunCode: 2010-11-17710:36:23 /D: TABLE OF CONTENTS Cover Page 1 Table -of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 9 HVAC System Heating and Cooling Loads Summary 12 EnergyPro 5.1 by EnergySok.. Job Number: ID: User Number: 5862 1 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Lamkin-Himka Res. Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family la Existing+ Addition/Alteration 11111712010 Date Project Address 50195 Doral Street La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,680 Addition 70 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ,❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity fiz) Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 2,610 Existing Wall Wood Framed R-19 1,983 Existing Slab Unheated Slab -on -Grade None 2,610 Perim = 266' Existing Roof Wood Framed Attic R-38 70 New Slab Unheated Slab -on -Grade None 70 Perim = 26' New Wall Wood Framed R-21 64 New Door Opaque Door None 20 Existing Door Opaque Door None 24 Existing FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Right (NE) 145.0 0.870 0.70 none none Bug Screen Existing Right (NE) 55.0 0.550 0.45 none none Bug Screen Existing Front (SE) 70.0 0.870 0.70 none none Bug Screen Existing Left (SM 48.0 0.870 0.70 none none Bug Screen Existing Left (Vtq 8.0 0.550 0.45 none none Bug Screen Existing Rear (NIM 80.0 0.870 0.70 none none Bug Screen Existing Front (SE) 13.0 0.870 0.70 none none Bug Screen New Left (SVtq 3.6 0.550 0.45 none none Bug Screen Existing Left (M 102.0 0.870 0.70 none none Bug Screen Existing Right (E) 20.0 0.870 0.70 none none Bug Screen Existing Front (S) 28.0 0.870 0.70 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Fumace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Existing Sleeping Area Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing Existing Living Area Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Qt . Type Gallons Min. Eff Distribution Status Energ Pro 5.1 by Energ Soft User Number: 5862 RunCode: 2010-11-17T10:36:2 ID: Page 3 of 13 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF-1 R Project Name Lamkin-Himka Res. Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family 0 Existing+ Addition/Alteration Date 11/17/2010 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System Existing Sleeping Area must serve only Sleeping Areas. The non-closable area between zones cannot exceed 40 sf and each zone must be controlled with a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA-6 HIGH MASS Design - Verify Thermal Mass: 225.0 It Exposed Slab Floor, 3.500" thick at Existing Sleeping Area HIGH MASS Design - Verify Thermal Mass: 975.0 ft Covered Slab Floor, 3.500" thick at Existing Sleeping Area HIGH MASS Design - Verify Thermal Mass: 70.0 ftz Covered Slab Floor, 3.500" thick at Addition The HVAC System Existing Living Area must serve only Sleeping Areas. The non-closable area between zones cannot exceed 40 sf and each zone must be controlled with a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA-6 must HIGH MASS Design -Verify Thermal Mass: 1,410.0 ftz Exposed Slab Floor, 3.500" thick at Existing Living Area HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. EnerqWro 5.1 by EnemySoft User Number: 5862 RunCode: 2010-11-17T10:36:2 ID: Page 4 of.13 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date Lamkin-Himka Res. Addition ❑ Multi Family m Existing+ Addition/Alteration 11/17/201 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 13.75 11.79 1.96 Space Cooling 109.44 109.37 0.08 Fans 25.41 25.26 0.15 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 148.60 146.42 2.18 Percent Better Than Standard: 1.5 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (SE) 135 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (SE) 552 111 Fuel Available at Site: Natural Gas (Svv) 896 162 Raised Floor Area: 0 (NM 328 80 Slab on Grade Area: 2,680 (NE) 888 220 Average Ceiling Height: 9.1 Roof 2,680 0 Fenestration Average U-Factor: 0.83 TOTAL: 573 Average SHGC: 0.67 Fenestration/CFA Ratio: 21.4% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company EQS, Inc. 0 0 Address 42335 Washington St. #F-330 Name Gina Rose-Starkey Citotate/Zip Palm Desert, CA 92211 Phone 760-674-2345 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Dual Designs- Address Name David Jackson P L16 City/State/Zip Phone 760-771-3626 Signed License # Date EnerPro 5.1 by EnerqySoft User Number: 5862 RunCode: 2010-11-17T10:36:2 ID: Pa e 5 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF-1 R Project Name Lamkin-Himka Res. Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family la Existing+ Addition/Alteration Date 1/17/201 OPAQUE SURFACE DETAILS Surface T e Area U- Insulation Joint Appendix Factor CavityExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,200 0.026 R-38 0 0 Existing4.2.1-A9 ExistingSleeping Area Wall 512 0.074 R-19 45 90 Existing4.3.1-A5 ExistingSleeping Area Wall 150 0.074 R-19 135 90 Existin 4.3.1-A5 Existing Sleeping Area Wall 80 0.074 R-19 225 90 Existing4.3.1-A5 ExistingSleeping Area Wall 96 0.074 R-19 270 90 Existing4.3.1-A5 ExistingSleeping Area Slab 225 0.730 None 0 180 Existing4.4.7-A 1 ExistingSleeping Area Slab 975 0.730 None 0 180 Existing4.4.7-A1 ExistingSleeping Area Wall 88 0.074 R-19 315 90 Existing4.3.1-A5 ExistingSleeping Area Roof 70 0.026 R-38 0 0 New 4.2.1-A9 Addition Slab 70 0.730 None 0 180 New 4.4.7-A1 Addition Wall 64 0.069 R-21 45 90 New 4.3.1-A6 Addition Wall 67 0.074 R-19 135 90 Existing 4.3.1-A5 Addition Wall 64 0.074 R-19 225 90 Existing 4.3.1-A5 Addition Roof 1,410 0.026 R-38 0 0 Existing 4.2.1-A9 Existing Living Area Wall 22 0.074 R-19 45 90 Existing 4.3.1-A5 Existing Living Area Wall 116 0.074 R-19 1351 90 1 Existing 4.3.1-A5 Existing Living Area FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC2 Azm Status Glazing Type Location/Comments 1 Window 24.0 0.870 NFRC 0.70 NFRC 45 Existing Double Metal Clear Existing Sleeping Area 2 Window 10.0 0.870 NFRC 0.70 NFRC 45 Existing Double Metal Clear Existing Sleeping Area 3 Window 25.0 0.550 NFRC 0.45 NFRC 45 Existing Glass Block Existing Sleeping Area 4 Window 15.0 0.870 NFRC 0.70 NFRC 45 Existing Double Metal Clear Existing Sleeping Area 5 Window 30.0 0.550 NFRC 0.45 NFRC 45 Existing Glass Block Existing Sleeping Area 6 Window 10.0 0.870 NFRC 0.70 NFRC 135 Existing Double Metal Clear Existing Sleeping Area 7 Window 48.0 0.870 NFRC 0.70 NFRC 225 Existing Double Metal Clear Existing Sleeping Area 8 Window 8.0 0.550 NFRC 0.45 NFRC 270 Existing Glass Block Existing Sleeping Area 9 Window 24.0 0.870 NFRC 0.70 NFRC 315 Existing Double Metal Clear Existing Sleeping Area 10 Window 56.0 0.870 NFRC 0.70 NFRC 315 Existing Double Metal Clear Existing Sleeping Area 11 Window 13.0 0.870 NFRC 0.70 NFRC 135 New Double Metal Clear Addition 12 Window 48.0 0.870 NFRC 0.70 NFRC 45 Existing Double Metal Clear Existing Living Area 13 Window 48.0 0.870 NFRC 0.70 NFRC 45 Existing Double Metal Clear Existing Living Area 14 Window 20.0 0.870 NFRC 0.70 NFRC 135 Existing Double Metal Clear Existing Living Area 15 Window 20.0 0.870 NFRC 0.70 NFRC 135 Existing Double Metal Clear Existing Living Area 16 Window 20.0 0.870 NFRC 0.70 NFRC 135 Existing Double Metal Clear Existing Living Area (1) LI-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window -HqtT Wd Ove hanq Left Fin Len H t LExt RExt Dist Len Ri ht Fin H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 5862 RunCode: 2010-11-17T10:36:2 ID: Page 6 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R Project Name Lamkin-Himka Res. Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 11/17/201 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area I Factor Cavi!Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments Door 201 1.450 None 135 90 Existing 4.5.1-A1 Existing Living Area Door 241 1.450 None 135 90 Existing 4.5.1-A1 Existing Living Area Wall 3861 0.074 R-19 225 90 Existing 4.3.1-A5 Existing Living Area Wall 108 0.074 R-19 270 90 Existing 4.3.1-A5 Existing Living Area Slab 1,410 0.730 None 0 180 Existing 4.4.7-A1 Existina Livinq Area Wall 160 0.074 R-19 315 90 Existing 4.3.1-A5 Existing Living Area Wall 70 0.074 R-19 90 90 Existing 4.3.1-A5 Existing Living Area Wall 64 0.074 R-19 180 90 Existing 4.3.1-A5 Existing Living Area FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 17 Window 1.8 0.550 NFRC 0.45 NFRC 225 Existing Glass Block Existing Living Area 18 Window 1.8 0.550 NFRC 0.45 NFRC 225 Existing Glass Block Existing Living Area 19 Window 12.0 0.870 NFRC 0.70 NFRC 270 Existing Double Metal Clear Existing Living Area 20 window 48.0 0.870 NFRC 0.70 NFRC 270 Existing Double Metal Clear Existing Living Area 21 Window 42.0 0.870 NFRC 0.70 NFRC 270 Existing Double Metal Clear Existing Living Area 22 Window 20.0 0.870 NFRC 0.70 NFRC 90 Existing Double Metal Clear Existing Living Area 23 Window 20.0 0.870 NFRC 0.70 NFRC 180 Existing Double Metal Clear Existing Living Area 24 Window 8.0 0.870 NFRC 0.70 NFRC 180 Existing Double Metal Clear Existing Living Area (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hanq Left Fin Len H t LExt RExt Dist Len Ri ht Fin H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 EnergyPro 5,1 by EnergySoft User Number: 5862 RunCode: 2010-11-17T10:36:2 ID: Pae 7 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Lamkin-Himka Res. Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+Addition/Alteration Date 911971209 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built Existing Sleeping Area Existing Sleeping Area 1,200 9,600 1985 Addition 70 560 Existing Living Area Existing Living Area 1,410 1 14,100 1985 Totals 1 701 2,6101 0 0 HVAC SYSTEMS S stem Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Existing Sleeping Area 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing Existing Living Area 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Existing Sleeping Area Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing Existing Living Area Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution RatedJCa Input Btuhor Energy Factor RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status CEC Standard MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control .2 w w a- Hot Water Piping Length n o v Q —I System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ ❑ ❑ ❑ ❑ ❑ EneMYPro 5.1 by EnemySoft User Number: 5862 RunCode: 2010-11-17T10:36:2 ID: Page 8 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF -1 R Project Name Lamkin-Himka Res. Addition Date 11111712010 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. 150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. 150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(')3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 5862 RunCode: 2010-11-17T10:36:23 /D: Page 9 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Lamkin-Himka Res. Addition 11111712010 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or. equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 5862 RunCode: 2010-11-17710:36:23 /D: Page 10 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Lamkin-Himka Res. Addition 11111712010 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with § 150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134 and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoff User Number. 5862 RunCode: 2010-11-17710:36:23 /D: Page 11 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lamkin-Himka Res. Addition Date 11/17/2010 System Name Existing Sleeping Area Floor Area 1,270 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 1,719 27,929 Return Vented Lighting 0 Return Air Ducts 2,368 Return Fan 01 Ventilation 230 9,409 Supply Fan 0 Supply Air Ducts 2,368 TOTAL SYSTEM LOAD 42,075 COIL HTG. Latent CFM 3,189 646 4,091 230 7,280 PEAK Heating System Sensible Output per System 51,000 23,357 Total Output (Btuh) 51,000 Output Btuh/s ft 40.2 1,659 Cooling System 0 Output per System 36,000 10,531 Total Output (Btuh) 36,000 0 Total Output (Tons) 3.0 1,659 Total Output (Btuh/s ft) 28.3 Total Output s ft/Ton 423.3 37,207 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Existing 3 ton 30,526 1,439 51,000 Airflow cfm/s ft 0.94 Airflow cfm/Ton 400.0 Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 30,526 1,439 51,000 Aug 3 PM Jan 1 AM Outside Air % 19.2% Outside Air cfm/s ft 0.18 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 61 OF Outside Air 230 cfm Supply Fan 1,200 cfm 69 OF 61 OF 105 OF Heating Coil 104 OF � ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 81/65°F 81/65°F 55/54°F c Outside AirAr 230 cfm Supply Fan Cooling Coil 1,200 cfm 74 162 OF 53.4% 57 / 54 OF ROOM 72 / 61 OF EnergyPro 5.1 by EnergySoft User Number. 5862 RunCode: 2010-11-17710:36:23 /D: Page 12 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lamkin-Himka Res. Addition Date 11/17/2010 System Name Existing Living Area Floor Area 1,410 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 2,006 Return Vented Lighting Return Air Ducts Return Fan Ventilation 115 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 79,000 33,692 2,564 738 26,979 Total Output (Btuh) 79,000 0 Output Btuh/s ft 56.0 2,857 1,917 Cooling System 0 0 Output per System 58,000 4,767 2,143 115 5,315 Total Output (Btuh) 58,000 0 4,707 0 Total Output (Tons) 4.8 2,857 1,917 Total Output (Btuh/s ft) 41.1 Total Output s ft/Ton 291.7 44,174 36,127 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Existing 5 ton 44,134 5,118 79,000 79,000 F Jan 1 AM Airflow cfm/s ft 1.42 Airflow cfm/Ton 413.8 Outside Air % 5.8% Total Adjusted System Output 44,134 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 5,118 Aug 3 PM Outside Air cfm/s ft 0.08 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 67 OF O Outside Air 115 cfm Supply Fan AL 2,000 cfm 69 OF 67 OF 105 IF Heating Coil 4 _ 104 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 76/62°F 76/62°F 55/54°F 01 c - Outside Air Ak- 115 cfm Supply Fan Cooling Coil 56 / 54 OF 2,000 cfm 52.4% ROOM 73 / 61 of 72 / 61 OF EnergyPro 5.1 by EnergySoft User Number: 5862 RunCode: 2010-11-17710:36:23 /D: Page 13 of 13