05-2951 (AR)C.vi�,_
P.O. BOX 1504 4
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Application Number: . 05=0000295i`""~
Owner:
Property Address:
79965 DOUBLE EAGLE WY
Dave ,White
APN:
775-250-004- - -
79-965 Double Eagle Way
Application description:
ADDITION - RESIDENTIAL
LA QUINTA, CA 92253
Property Zoning:
LOW DENSITY RESIDENTIAL
Application valuation:
39673
1
Contractor:
Applicant:
Architect or Engineer:
EDWARDS CONSTRUCTION, BOB
51455 DESERT CLUB DRIVE
LA QUINTA, CA 92253
(760)777-8202
Lic. No.: 684857
LICENSED CONTRACTOR'S DECLARATION .-
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Sec '"on 000) f Division 3 of th 'ness n s nal? Code, my License is in full force and effect.
L' enseji lass: /B� License : 684857
Date:�1 "'� Contractor: 1_
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_ 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERM[T
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 9/13/05
IF
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier VIRGINIA SURETY Policy Number 00500027012
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I,sjeCRr be e s Wmwith
orkers' compensation provisi sof Section
+I J337700 of the Labo d 1 all f hwitthose provisi s.
Date:"W Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. - Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of s ermit, or cessation of work for 180 days will subject
permit to cancellation.
I certify tj�atlve read this application and state th thea ove i o is r I agree to comply with all
city nd #ordinances and state laws relating to uildi gons ctio re uthorize representatives
is enter upon the above-mentioned pro rt r in's a 'o p rposes.
Date �` f�J/ Signature (Applicant or Agent):
Application Number . . . . . 05-00002951
Permit
BUILDING PERMIT
Additional desc .
Permit Fee . . . .
349.50
Plan Check Fee
227.18
Issue Date
Valuation . . . .
39673
Expiration Date
3/12/06
Qty Unit Charge
Per
Extension
BASE
FEE
252.00
15.00 6.5000
----------------------------------------------------------------------------
THOU BLDG
25,001-50,000
97.50
Permit
ELECT - ADD/ALT/REM
Additional desc .
Permit Fee . . . .
32.19
Plan Check Fee
8.05
Issue Date . . . .
Valuation
0
Expiration Date
3/12/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
491.00 .0350
----------------------------------------------------------------------------
ELEC
NEW RES - 1 OR 2 FAMILY
17.19
Permit
GRADING PERMIT
Additional desc .
Permit Fee . . . .
15.00
Plan Check Fee
.00
Issue Date . . . .
Valuation . . . .
0
Expiration Date
3/12/06
Qty Unit Charge
Per
Extension
----------------------------------------------------------------------------
BASE
FEE
15.00
Permit . . .
MECHANICAL
Additional desc . .
Permit Fee . . . .
39.50
Plan Check Fee
9.88
Issue Date . . . .
Valuation . . . .
0
Expiration Date
3/12/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
1.00 9.0000
EA MECH
FURNACE <=100K
9.00
1.00 9.0000
EA MECH
B/C <=3HP/100K BTU
9.00
1.00 6.5000
----------------------------------------------------------------------------
EA MECH
VENT FAN
6.50
Permit . . PLUMBING
Additional desc . .
LQPERMIT
Application Number .
. . . .
05-00002951
Permit . . . . . .
PLUMBING
Permit Fee . . . .
42.00
Plan'Check Fee
10.50
Issue Date . . . .
Valuation . . .
. 0
Expiration Date
3/12/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
4.00 6.0000
EA PLB
FIXTURE
24.00
1.00 3.0000
EA PLB
WATER INST/ALT/REP
3.00
------------------------------------------------------------------
Special Notes and Comments
----------
Casita Addition (491
sqft) MUP
05-559
----------------------------------------------------------------------------
Other Fees . . . .
. .
ART IN PUBLIC PLACES -RES
20.00
ENERGY REVIEW FEE
22.72
STRONG MOTION (SMI) - RES
3.96
Fee summary Charged
-----------------
Paid Credited
Due
----------
Permit Fee Total
478.19
------------------------------
.00 .00
478.19
Plan -Check Total
255.61
.00 .00
255:61
Other Fee Total
46.68
.00 .00
46.68
Grand Total
780.48
.00 .00
780.48
1%
LQPERMIT
i It
Remit #
Project Address:
A. P. Number: -77250 C
Legal Description: Lc�4
Contractor:
Address-. 1:17
City, ST, Zip: QI
Telephone: -7—/—"7 `' C O
State Lic. #
, Designer: �
Address: 4 ' .. 2
City';ST, Zip: Obs
Tele fi
one: 7
P "[ C>
State laic #:
Name of Contact Person:
Telcnhon'c # of Contact Person:
# Submittal Rcq'd
Plan Sets
Structural Calcs.
Truss Calcs. 8/
Titic 2'4 Calcs. .
Flood ptaiit plan
Grading plan
Subcontactor List
City of D Quit]
Building 8t Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Owner's Name:"�
X Address: ?C) - S
City, ST, Zip: LOA"
/ Telephone:.
ac,45 Project Description:
Lic. #:
Construction Type:
Occu P ancv:
•
airPro1eet n Demo
Ne Add'n Al to RcP
Sq. Ft.: #Stories: #Units;.
–
� � Project:
Grading
Estimated Value of
''` Revien eadv for corrections/issue
APPLICANT: DO NOT WRITE BELOW THIS LINE
Planning Approval
Recd TRACMNC
PERMIT FEES
Plan Check submitted �g
Item Amount
Reviewed, ready for corrections $ 8
Plan Check Deposit
Called Contact Person 8
Plan Chick Balance
Plans picked up'F
Construction
Q� Q
Plans resubmitted �j v/p2-/
Dtechanical
2"' Review, ready for corrections ssucQ!!F i Electrical
C211ed Contact Person 0011
Plumbing
Grant Deed
Plans picked, up
II.O.A. Approval
Ylans.resubmitttd
Grading
IN IIOUSE:-
''` Revien eadv for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
—
f L
Tota t Permit r ecs
•'.
/3
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road BERMUDA DUNES O
RANCHO MIRAGE CJ
Date 11/28/05 La Quinta, CA 92253 r INDIAN WELLS
DESERT
No. 27879 (760) 771-8515 Z.� PALM LA QUINTA
Zf!-��INDIO y�
0
Owner Dave White APN # 775-250-004
Address 79-965 Double Eagle Way Jurisdiction La Quinta
City La Quinta Zip 92253 Permit #
Tract # Study Area
Type Residential Addition No. of Units 1
Lot # No. Street S.F. Lot # No. Street S.F.
Unit 1 79965 Double Eagle Way 491 Unit 6
Unit 2 Unit 7
Unit 3 Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments Attached Casita - Exempt
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 491 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Bob Edwards Check No.
Name on the check Telephone
Funding Exempt
By Dr. Doris Wilson
Superintendent
Fee collected /exempted by Sharon
Signature
ilvrey
1
Payment Recd µ w $0.00 7 7, --
_ ?,
river/Wd& r
•l ,
NOTICE: Pursuant to Government Code Section 66020(d)(1), this AUAerve to notify you that the 90 -day approval period in which you may protest the fees o
r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original -Building Department/Applicant Copy -Applicant/Receipt Copy -Accounting
CONCORDE *CONSULTING CROUP, INC.
ENGINEEEKING & CONSTRUCTION MANAGEMENT
3305 C—AMINO DEL RIO SOUTH, # 350
SAN DIEGO, CA 92108
PF-(: (61.9) 516-337"1 FAX: (619) 316-3388
NIFMORANDUM/FAX COVER SHEET
TO: i"WOM:
Robert Pitchford KRIPA
FAX W"NIBL'R. NO. (1):
NI OW; NIA181,12: `:F.NDEJ)lls 10IT"A! NUM141; P.
iR iL +0141 T a C A I I TA
17
X k.,'K("Tt'-NT X PDR Rt*,.\;(I-'-):' X l'jJ%A" il--' X, W
" I Y D lu.-cycm.,
WE FLWE RE-VIEWEl') T141". 'TRU'SS Dp AWT NGS PROVIDED FORTHIS PROJECT.
A
WE FIND -111ATTHE TRUSS DIKAWINGS ARE,. IN, GpF.NE-'RAl. CONFORMANCE
WITH DESIGN INTENTANI', (*()Ns*rRU(-"1'1('.)N L)"*'(AJ'NMFN'FS
PLEASE CALL IF 'YOU I T.rVvF'ANY Q�.:ESTIONS,
flANKS
KRIPANARAY.NAN
- REPORTTM
ESR -1 334 '
Issued June 1, 2004
This report is subject to re-examination in one year.
ICC Evaluation Service, Inc. BusineseVRegional OffiOe a 5350 Workmen Mil Road, WMer, California 90601 ■ (562) 69DOW
Regional Office ■ 900 Montclair Road, Suite A, Birmingham, Alabama 35213 ■ (205) 599.9800
www.icc-es.org Regional Office ■ 4051 West Flossnim Road, Country Club HUs, Illinois 60478 ■ (708) 7992305
DIVISION: 08—DOORS AND WINDOWS
Section: 08620—Unit Skylights
REPORT HOLDER:
SOLATUBE INTERNATIONAL, INC.
2210 OAK RIDGE WAY
VISTA, CALIFORNIA 92081-8341
(760)597-4400
www.solatube.com
Info®solatube.com
EVALUATION SUBJECT:
SOLATUBE TUBULAR SKYLIGHTS
1.0 EVALUATION SCOPE
Compliance with the following codes:
■ 2000 International Building Code® (IBC)
■ 2000 International Residential CodeP (IRC)
■ 1997 Uniform Building Code TM (UBC)
Propertles evaluated:
■ Durability
■ Structural
■ Weather resistance
2.0 USES
The Solatube skylights described in this report are plastic -
glazed tubular skylights complying with Chapters 24 and 26
of the IBC and UBC and Section 8308.6 of the IRC.
3.0 DESCRIPTION
Solatube skylights are tubular skylights consisting of a clear
acrylic light -transmitting dome with an internal curved
reflector; a roof -mounted support base (flashing); an upper -
tube -supporting element (dome -ring); reflective light -
conducting tubing of either adjustable 0 -to -30 -degree elbows,
0 -to -90 degree elbows, and/or straight extension tubes; a
lower -tube -supporting element (either ceiling ring or round -to -
square -transition); and a ceiling -mounted light -diffusing
assembly (diffuser). The Solatube skylights are available in
10-, 14- or 21 -inch -diameter (254, 256 or 533 mm) models.
See Figure 1 and Table 1 of this report for additional details.
4.0 INSTALLATION
4.1 General:
The Solatube skylights are prepackaged for field installation,
with all components, attachments, and instructions in the
shipping carton. A 10.5-,14.5- or 22 -inch -diameter (267, 368
or 559 mm) round hole, for the 10-, 14- and 21 -inch -diameter
(254, 256 or 533 mm) skylights, respectively, shall be cut in
the roof sheathing and ceiling below the attic space. The
skylight support base shall be attached to the roof sheathing
using eight No. 10 by 2 -inch -long (51 mm) stainless steel or
dacrotized-finish steel sheet metal screws for the 10- and 14 -
inch (254 and 256 mm) units, and sixteen screws for the 21 -
inch (533 mm) unit. A felt or foam weather seal shall be
adhered to the top edge of the skylight support base. The
reflective top tube with attached dome ring shall then be
inserted into the skylight support base opening. A curved
reflector shall be mounted inside the dome. The dome shall
be secured to the support base using four No. 8 by 3/4 inch -
long (19 mm) stainless steel or dacrotized-finish steel pan or
truss head sheet metal screws for the 10- and 14 -inch (254
and 256 mm) units, and six No. 8 by 3/4 inch -long (19 mm)
screws for the 21 -inch (533 mm) unit. The 10- and 14 -inch
(254 and 256 mm) units terminate at the ceiling into the
ceiling ring installed, using four No. 6 by 1,5/, -inch -long (41
mm) corrosion resistant, bugle head, drywall screws and four
plastic self-locking anchors or four plastic anchors only. See
Figure 2 of this report for additional details. The 21 -inch (533
mm) unit terminates at the ceiling into a square -to -round
plastic transition box set Into the framework on a suspended
T -bar ceiling system, or is installed into a gypsum ceiling
using four No. 6 by 15/, -inch -long (41 mm) corrosion resistant,
bugle head drywall screws. See Figure 6 of this report for
additional details. The 10- and 14 -inch -diameter (254 and 256
mm) light diffusers shall be secured onto the ABS ceiling ring
by means of a one-eighth clockwise turn or by means of four
plastic diffuser clips. The 21 -inch (533 mm) light diffuser shall
be secured onto the square -to -round transition box by means
of four diffuser latches or, for the 21 -inch (533 mm) open
ceiling light diffuser, by means of four plastic diffuser clips.
The lowest edge of the support base turret opening shall be
at least 4 inches (102 mm) above the plane of the roof
covering. This may be accomplished with installation of the
optional Solatube 2 -inch -high (51 mm) galvanized or
aluminized -steel turret extension. See Figure 3 of this report
for additional details. The 4 -inch (102 mm) clearance
requirement and the turret extension are not required on roofs
of Group R, Division 3 (UBC) or Group R-3 (IBC), occupancy
with a minimum slope of 3:12 (25%).
Where a Class A, B or C roof covering is required, skylight
dome edges shall be protected with the application of
galvanized or aluminized steel, dome -edge protective rings,
as shown in Figure 4 of this report, with the exception of the
21 -inch (533 mm) unit with 8 -Inch- (203 mm) or 11 -inch -high
(279 mm) flashing, or any model with curb -mount flashing on
curbs a minimum of 8 inches (203 mm) high.
4.2 Tile Roofs:
For installation on a tile roof, a "dead -soft" 0.020 -inch -thick
(0.51 mm) pleated aluminum sheet shall be used as
malleable counter -flashing. After the appropriately sized hole
for the 10- or 14 -inch (254 and 256 mm) Solatube skylight is
t1REPCRTS'-are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject
of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, Inc., express or implied, as to any finding or other matter in this report or as to any
product covered by the report
Copyright 0 2004 Page 1 of 5
Page2 of 5 ESR -1334
cut in the roof sheathing, a metal base flashing shall be
placed over the hole and secured in place using eight No. 10
by 2 -inch -long (51 mm) stainless steel or dacrotized-finish
steel panhead sheet metal screws. See Figure 5 of this report
for additional details. Tiles surrounding the flashing are cut
according to the profile of the flashing, with a maximum
clearance of /2 inch (12.7 mm) from the flashing. The pleated
aluminum sheet, with a circular hole cut in the centerto match
the flashing, shall be placed over the flashing. A galvanized
or aluminized steel turret extension ring shall be placed over
the opening of the base flashing, sandwiching the aluminum
sheet between the flashing and turret extension ring. The
aluminum sheet shall then be secured to the top of the tiles
in the course below using non -alkaline and non -acidic tile
mastic. The remaining sheet shall be tucked under the tiles in
the upper course.
When installing the system with high-profile tiles, the upper
and side edges of the pleated aluminum shall be bent up to
form a "bird stop" and water seal under the upper course tiles
and surrounding field tiles.
4.3 Allowable Loads:
The allowable positive and negative loads for the 10- and 14 -
inch -diameter (254 and 356 mm) skylights is 100 psf (4.79
kPa), and 35 psf (1.67 kPa) for the 21 -inch -diameter (533
mm) skylight.
5.0 CONDITIONS OF USE
The Solatube skylights described in this report comply with,
or are suitable alternatives to what is specified in, those
codes specifically listed in Section 1.0 of this report, subject
to the following conditions:
5.1 Installation shall be in accordance with this report,
Section 2405 of the IBC, Section R308.6 of the IRC and
Sections 2409 and 2603.7 of the UBC, as applicable,
and the manufacturer's published installation
instructions. In the event of a conflict between this report
and the manufacturer's published installation
instructions, this report shall govern.
5.2 The maximum positive and negative loads shall be as
described in Section 4.3 of this report.
5.3 The use of the skylights as a component of fire -
resistance -rated assemblies is outside the scope of this
report.
6.0 EVIDENCE SUBMITTED
6.1 Manufacturer's published installation instructions.
6.2 Data in accordance with the ICC -ES Acceptance
Criteria for Plastic Skylights (AC16), dated October
2003.
6.3 A quality control manual.
7.0 IDENTIFICATION
Solatube skylight components shall be packaged in boxes
bearing the Solatube name and address and the evaluation
report number (ESR -1334). Additionally, each skylight shall
have a permanent label, conspicuously located, that bears
the Solatube name and address, the evaluation report
number, the plastic classification (CC -2) and the thickness of
the plastic glazing material prior to forming. The 21 -inch -
diameter (533 mm) skylight shall also have a safety label
applied to each unit, warning of the risk of fall.
TABLE 1—SOLATUBE SKYLIGHT MATERIAL COMPONENTS
COMPONENTS
SKYLIGHT DIAMETER
10 -INCH 14 -INCH 21 -INCH
Dome—Atofina, Plexiglas DR 101 acrylic, 0.125 Inch thick, CC -2. See ICC -ES evaluation
report ER -1084
X
X
Dome—Atofina, Plexiglas DR 101 acrylic, 0.143 inch thick, CC -2. See ICC -ES evaluation
report ER -1084
X
Support base—Galvanized or aluminized steel, 0.030 inch thick
X
X
X
Turret extension—Galvanized or aluminized steel (0.032 inch thick)
X
Turret extension ring—Galvanized or aluminized steel (0.030 inch thick)
X
X
Square -to -round transition lower tube supporting element—Polypropylene, PVC or ABS
plastic (0.060 inch thick)
X
Dome edge protective ring—Galvanized or aluminlzed steel (0.040 Inch thick)
X
X
X
Tile roof kit (0.020 -inch -thick, dead soft, pleated aluminum sheet)
X
X
Aluminum reflective tube, 0.020 inch thick (polished)
X
X
X
Light diffuser—Ac ic, 0.100 inch thick, CC2
X
X
X
For SI: 1 Inch = 25.4 mm.
• ,Page 3 of 5 ESR -1334
Minch 14 -inch
FIGURE 1—SOLATUBE 10-, 14 AND 21 -INCH UNITS
21" UNIT
n
A of ft(W s6. ms +e. PwwPs
e a,ma31"s %. cccft zco ►eco
Pnuws "S NO
C omaft ft"m mmoyscam
w.
FIGURE 2—DETAILED DESCRIPTION OF 10 -INCH SOLATUBE
..Page 4 of 5 ESR -1334
FIGURE 3—TURRET EXTENSION
l
.,�,:._•�---".fig
16 UNIT
FIGURE 4-10- AND 14 -INCH SOLATUBE DOME RING
LIFMNO. OIY. PARI NO. DISCRIFFICH
1
1 MSE RAWW.
1 OCMFD
7
F61N30f1sumfoliTu
J
1 =%l MG
PLASTIC
A
1 Dow
Pt/WIC
6
12 60 FFLF PA Cl SCREW
siILLCIACROIDFD
VIEW
slfill. CACROMD
e
1 11.9E FOPAWU F
Rm—
FLA IWN V1 MLi
ADPAWAPLEA110£FIFFI
0
0 C
M4
FIGURE 5—TILE ROOF INSTALLATION PROCEDURE
• - page 5 of 5 ESR -1334
Ir SEV fL^sK*G top MUMMY
0 K CEUVO IOtt0w /S$EVA:Y
FIGURE 6—TYPICAL INSTALLATION OF 21 -INCH UNIT (INCLUDING DOME RING)
TITLE 24 REPORT
Title 24 Report for:
Mr. & Mrs. Dave White-Casita
79-965 Double Eagle
La Quinta, Ca 92253
J*CPar.A*SP/
Project Designer:
Robert A Pitchford, Design & Drafting
41-625 Eclectic, #A2
Palm Desert, Ca 92260
(7.60) 346-2856
Report Prepared By:
Tim Scott
H & H Air Conditioning
74-991 Joni Drive #20
Palm Desert, CA 92260-2043
(760) 340-3088
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCT N
DA /1Z/L 13Y
Job Number:
Date:
8/19/05
i The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC (415) 883-5900.
EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533
A
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Checklist
Form C -2R Computer Method Summary.,.,
HVAC System Heating and Coolingloads Summary
Room Load Summary
Room Heating Peak Loads
Room Cooling Peak Loads
1
2
3
6
8
12
13
14
15
EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533 1
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Mr. & Mrs. Dave White-Casita 8/19/05
ro/ec Title a e
79-965 Double Eagle La Qulnta
vro/ec1 Aaaress
H & H Air Conditioning (760) 340-3088
Documentation Autnor j a ep one
Computer Performance 15
Building ermi
Plan Check / Date
Field ec a e
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area:
Total Conditioned Slab Area:
Building Type:
(check one or more)
® Single Family Detached
❑ Single Family Attached
❑ Multi -Family
491 ft2 Average Ceiling Height: 9.0 ft
491 ft2
❑ Addition
❑ Existing Building
❑ Existing Plus Addition
Front Orientation: (Southwest) 225 deg Floor Construction Type: FX -1 Slab Floor
Number of Dwelling Units: 1.00
Number of Stories:
BUILDING SHELL INSULATION
Component
Type
R-38 Roof (R.38.2x14.16)
R-21 Wall (W.21.2x6.16)
Slab On Grade
Slab On Grade
FENESTRATION
❑ Raised Floor
Frame
Type
Const.
Assembly
U -Value
Location/Comments
(attic, garage, typical, etc.)
Wood
0.028
Exterior Roof
Wood
0.059
Exterior Wall
n/a
0.756
Covered Slab w/R-0.0 Perimeter Insulation
n/a
0.756
Exposed Slab w/R-0.0 Perimeter Insulation
Shading Devices
Type
Orientation
Area
Fenestration
Exterior
Overhang Side Fins
(SF)
U -Factor
SHGC
Shading
Yes / No
Yes / No
Skylight
0.5
0.80
0.39
None
❑
X❑
❑ x❑
Right
(Southeast)
15.0
0.72
0.59
Bug Screen
❑
N
El NFront
(Southwest)
25.0
0.87
0.59
Bug Screen
❑X❑
❑X❑
Front
(Southwest)
40.0
0.55
0.53
Bug Screen
❑
x❑
❑ a
Left
(Northwest)
14.8
0.72
0.59
Bug Screen
❑
x❑
❑ x❑
❑
❑
❑ ❑
❑
❑
❑ ❑
❑
❑
❑ ❑
❑
❑
❑ ❑
❑
❑
❑ ❑
❑
❑
❑ ❑
1:1
El
1:1 El
Run Initiation
Time: 08/17/05 09:07:59
Run Code: 1124294879
EnergyPro 3.1 By EnergySoft
User Number: 5533
Job Number:
Page:3 of 15
Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
Mr. & Mrs. Dave White-Casita 8/19/05
rojec t e a e
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat Location /
pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments
Split Heat Pump 7.30 HSPF Ducts in Attic 4.2 Setback HVAC -1
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location
heat pump, evap; cooling) (SEER) (attic, etc.)
Duct Thermostat Location /
R -Value Type Comments
Split Heat Pump
11.0 SEER
Ducts in Attic
4.2
WATER HEATING SYSTEMS
Rated 1
Water Heater
Water Heater
Distribution
# in Input
System Name
Type
Type
Syst. Btu/hr
A.O. Smith FSG -30-222
Small Gas
Standard
1 32,000
Setback HVAC -1
Tank .Energy Fact' 1 External
Cap. or Recovery Standby Tank Insul.
(gal) Efficiency Loss (%) R -Value
30 0.62 n/a n/a
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name:
Title/Firm
Address:
Robert A Pitchford, Design & Drafting
41-625 Eclectic, #A2
Name:
Title/Firm
Address:
Tim Scott
H & H Air Conditioning
74-991 Joni Drive #20
Palm Desert, Ca 92260 Palm Desert, CA 92260-2043
Telephone: Telephone: (7 0) 340-3101,88
Lic. #:
p� gyl �/0 s
gna ure) ( te) (signature) (date)
nforcement gency
Name:
Title/Firm:
Address:
Telephone:
signature/stamp (date)
Run Initiation Time: 08/17/05 09:07:59 Run Code: 1124294879
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:4 of 15
Certificate of Compliance: Residential (Addendum) CF -1 R
Mr. & Mrs. Dave White-Casita 8/19/05
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
. _ , .. , .... r .. ,..�.... ... ......,. Plan Field
The HVAC System "HVAC -1" includes credit fora Radiant Barrier installed per Section 8.13 of the Residential Manual.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. an Field
e System includes Retrigerant Charge and Airflow Credit (ora certified HERS rater must provicle
verifification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC -1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
un nitlatlonTime: un Code: 1124294879
EnergyPro 3.1 By Energysoft User Number: 5533 Job Number: Page:5 of 15
Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION 'Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Building Envelope Measures
®'§150(a): Minimum R-19 ceiling insulation.
❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value.
Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
®"§150(c):
not apply to exterior mass walls).
❑ ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.
§150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no
❑
greater than 2.0 perm/inch.
® §118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
Ej§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
® § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
150(e): Installation Fireplaces,
§ of Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
®§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
§150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
® §150(i): Setback thermostat on all applicable heating and/or cooling systems.
® §1506): Pipe and Tank Insulation
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation. .
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:6 of 15
Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk
(') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are
shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
CU'§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
duct tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of the material.
§ 114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance
heating, and no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or
spas.
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
(� § 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§118 (f): Cool Roof material meet specified criteria
I
Lighting Measures
§150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
I
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
JX] I §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved.
3,1 By EnergySoft User Number: 5533 Job Number: Page:7 of 15�
Computer Method Summary (Part 1 of 3) C -2R
Mr. & Mrs. Dave White-Casita 8/19/05
-Project T li -Date
79-965 Double Eagle La Quinta
-Project Ad- ress BuilaingPe�mif
H & H Air Conditioning (760) 340-3088 P>an check/Date
-Documents iAu ofd a ep one
Computer Performance 15 Field C eh c�C/Da e
-Compliance Method -(Package or Compu er Climate one
Source Energy Use
(kBtu/sf-yr)
Space Heating
Space Cooling
Domestic Hot Water
Totals
Conditioned Floor Area:
Building Type:
Building Front Orientation:
Number of Dwelling Units:
Number of Stories:
Design
4.11
57.66
38.19
99.96
BUILDING ZONE INFORMATION
Zone Name
Proposed
Design
3.44
65.25
30.78
99.47
491
Single Fam Detached
(Southwest) 225 deg
1.00
1
Compliance
Margin
0.67
-7.59
7.41
0.49-
491
.49
X❑ Slab Floor
Floor Construction Type: ❑ Raised Floor
Total Fenestration Area: 19.4%
Total Conditioned Volume: 4,419
Slab Floor Area: 491
# of
Floor Area Volume Units Zone Type
HVAC -1 491
OPAQUE SURFACES
Act.
Type
Area
U -Fac.
Azm.
Tilt
Roof _
_ 490
0.028
0
20
Wall
180
0.059
45
90
Wall
201
0.059
135
90
Wall
115
0.059
225
90
Wall
201
0.059
315
90
Som
Gains
Y/N
4,419 1.00 Conditioned
Form 3 Reference
R-38 Roof (R.38.2x14.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
Casita
Casita
Casita
Casita
Casita
Thermostat Vent
Type Hgt. Area
Setback 2 n/a
Location / Comments
Run Initiation Time: 08/17/05 09:07:59 Run Code: 1124294879 —�
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:8 of 15
Computer Method Summary (Part 2 of 3) C -2R
Mr. & Mrs. Dave White-Casita 8/19/05
Project Title -Date
Ll- Act. Glazing Type Location/
# Type Area Factor SHGC Azm. Tilt Comments
1
Skylight Left
North
0.5
0.800
0.39
0
20 Double Metal Tinted Default
Casita
2
Window Right
(Southeast)
7.0
0.720
0.59
135
90 Double Metal Tinted Default
Casita
3
Window Right
(Southeast)
4.0
0.720
0.59
135
90 Double Metal Tinted Default
Casita
_
4
Window Right
(Southeast)
4.0
0.720
0.59
135
90 Double Metal Tinted Default
Casita
_
5
Window Front
(Southwest)
15.0
0.870
0.59
225
90 Double Metal Tinted Default
Casita
_
6
Window Front
(Southwest)
40.0
0.550
0.53
225
90 Double NonMtl Tinted Default
Casita
7
Window Front
(Southwest)
10.0
0.870
0.59
225
90 Double Metal Tinted Default
Casita
8
Window Left
(Northwest)
6.8
0.720
0.59
315
90 Double Metal Tinted Default
Casita
9
Window Left
(Northwest)
4.0
0.720
0.59
315
90 Double Metal Tinted Default
Casita
10
Window Left
(Northwest)
4.0
0.720
0.59
315
90 Double Metal Tinted Default
Casita
INTERIOR AND EXTERIOR SHADING
Window
Overhang Left Fin
Right Fin
#
Exterior Shade Type
SHGCHgt.
Wa-
ten. Rgt: - xE t. RExt. -ist—Len. FIT. -Dist.
Len. Rgi.
1—None
1-00
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8—
Bug Screen
0:76-
9
Bug Screen
0.76
--
10
Bug Screen
0.76
---
Run Initiation Time: 08/17/05 09:07:59
Run Code: 1124294879
EnergyPro 3.1
By EnergySoft
User Number: 5533
Job Number:
Page:9 of 15
Computer Method Summ rj'"� �`r""'' (Part 3 of 3) C -2R
Mr. & Mrs. Dave White-Casita 8/19/05
-Project Trtle -Date
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Location
Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. 'Comments
PERIMETER LOSSES
F2 Insulation
Type Length Factor R -Val. Depth Location / Comments
Slab Perimeter 65 0.76 0.0 0 Casita
Slab Perimeter 23 0.76 0.0 0 Casita
HVAC SYSTEMS
Heating Equipment Minimum Distribution Type
Type (furnace, heat Efficiency and Location Duct Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments
Split Heat Pump-
7.30 HSPF
Ducts in Attic
4.2 Setback
HVAC -1
Hydronic Piping Pipe
Pipe
Insul.
System Name Length
Diameter Thick.
Cooling Equipment
Minimum
Duct
Type (air conditioner,
Efficiency
Location
Duct Thermostat
Location /
heat pump, evap. cooling)
(SEER)
(attic, etc,)
R -Value Type
Comments
Split Heat Pump
11.0 SEER
Ducts in Attic
4.2 Setback
HVAC -1
WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul.
Water Heater Water Heater Distribution. # in Input Cap. . or Recovery Standby R -Value
System Name Type TypeSyst. (Btu/hr) (gal) Efficiency Loss (%) Ext.
A.O. Smith FSG -30-222 Small Gas Standard 1 32,000 30 0.62 n/a n/a
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
_ Run Initiation Time: 08/17/05 09:07:59 Run Code: 1124294879
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:10 of 15
Computer Method Summary (Addendum) C -2R
Mr. & Mrs. Dave White-Casita 8/19/05
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
.....,................... y......Y ... ..w .ter.•.•.. . J•. -•..—•.v....1 . •. v•....—n I. a v...—... L—.
The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. an ie
ld
e HVAC 5ySffM--RVAC--I-!nC—I—UaTS-Retrigerant Charge 5nd Airtlow Credit (ora certified HERS rater—m—u—sf—provide
verifification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC -1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
Run Initiation I Ime: u8/17/u5 u9:u7:59 Run Code: 1124294879
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:11 of 15
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Mr. & Mrs. Dave White-Casita 8/19/05
SYSTEM NAME FLOOR AREA
HVAC -1 491
Number of Systems
1
Heating System
Output per System
22,600
Total Output (Btuh)
22,600
Output (Btuh/sqft)
46.0
Cooling System
Output per System
24,000
Total Output (Btuh)
24,000
Total Output (Tons)
2.0
Total Output (Btuh/sqft)
48.9
Total Output (sgft/Ton)
245.5
Air System
CFM per System
800
Airflow (cfm)
800
Airflow (cfm/sqft)
1.63
Airflow (cfmrron)
400.0
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
26.0 of
310�
Outside Air
0 cfm
69.5 of
11.0 / 77.6 of
310
OutsideA
0 cfm
74.5/60.8 of
69.5 of 69.5 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
I Sensible
404 8,270 529 9,223
0
413 461
0 0
a 0 0 0 0
0 0
413 461
9,097]:::::::0 10,146
HVAC EQUIPMENT SELECTION
CARRIER 38QR024C31 17,209 2,839 14,864
Total Adjusted System Output 17,209 2,839 14,864
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
earn Temperatures at Time of Heating ea
86.9 of
Su I Air D t
Supply Fan Heating Coil
800 cfm
74.5/60.8OF 74.5/60.8OF
Roti irn Air n, irtr
54.3 / 53.2 of
Supply Fan Cooling Coil
800 cfm
oollnq tea
�, Return Air Ducts Y
pp y uc s
86.4 of
ROOMS
70.0 of
Supply Air Ducts
54.8 / 53.4 of
46.4% R.H. i ROOMS-]
74.0 / 60.6 of
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: PageA2 of 15
ROOM LOAD SUMMARY
PROJECT NAME
Mr. & Mrs. Dave White-Casita
DATE
8/19/05
SYSTEM NAME
HVAC -1
FLOOR AREA
491
IROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Casita
asi a
1
404
8,270
0
404
8,270
0
529
9,223
PAGE TOTAL 1404 8,2701 0 5291 9,223
TOTAL 404 8,270 529 9,223
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:13 of 15
ROOM HEATING PEAK LOADS
R-38 Roof (R.38.2x14.16)
Double Metal Tinted Default
R-21 Wall (W.21.2x6.16
Double Metal Tinted Default
Double Metal Tinted Default
Double NonMtl Tinted Default
Slab -On -Grade
490.5
X
X
X
X
X
X
X
x
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0.0280
X
X
X
X
X
x
X
x
X
x
x
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Project Title
Mr. & Mrs. Dave White-Casita
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
604
Date
18/19/05
0.8000
Room Information
Design Conditions
697.2
0.0592
Room Name
Floor Area
Indoor Dry Bulb Temperature
I
Casita
491
70 OF
Time of Peak
Outdoor Dry Bulb Temperature
0.7200
,tan 12 am
26°F
Conduction
Area U -Value
AT °F
Btu/hr
R-38 Roof (R.38.2x14.16)
Double Metal Tinted Default
R-21 Wall (W.21.2x6.16
Double Metal Tinted Default
Double Metal Tinted Default
Double NonMtl Tinted Default
Slab -On -Grade
490.5
X
X
X
X
X
X
X
x
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0.0280
X
X
X
X
X
x
X
x
X
x
x
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
44.0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
604
0.5
0.8000
44.0
18
697.2
0.0592
44.0
1,816
29.8
0.7200
44.0
944
25.0
0.8700
44.0
957
40.0
0.5500
44.0
968
perimeter = 88.0
44.5
3,916
_
items snown warn an asrensK t I genote conaucuon rnrougn an interior surtace to anotner room. Page Total: 9,223
Infiltration: I 1.00 x 1T064x 491 x 9.00 x 0.00 160 x _
LSch—mule Ate Sensible Area Ceiling eight ACH
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 9,223
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 14 of 15 1
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Mr. & Mrs. Dave White-Casita 8/19/05
Project Title Date
Room Name Casita
Design Indoor Dry Bulb Temperature: 740F
Design Outdoor Dry Bulb Temperature: 112°F
Design Temperature Difference: 380F
Conduction Area U -Value DETD' Btu/hr
X
(Skylight)
55.0
=
755
X
Window
38.0
=
15
X
(Southwest)
34.6
=
1,428
X
4.0
38.0
=
815
X
4.0
38.0
=
826
X
15.0
38.0
=
836
X
X
X
1. Design Equivalent Temperature Difference (DETD) Page Total 4,677
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
Skylight_
(Skylight)
Window
(Southeast)
Window
(Southeast)
Window
(Southeast)
Window
(Southwest)
Window
(Southwest)
Window
Window
Window
(Window
(Southwest)
(Northwest)
(Northwest)
(Northwest)
0.0
x
X
x
x
X
x
x
x
x
X
1 s +
15 +
15 +
151+
15 +
15 +
15 +
15 +
15 +
1 +
0.5
X
X
x
X
X
X
X
x
X
X
152)
X
X
X
X
X
X
x
0.448
=
=
=
=
=
=
=
=
__
=
34
0.0
7.0
62)x
0.657
285
0.0
4.0
62)
0.657
163
0.0
4.0
62)
0.657
163
0.0
15.0
62)x
0.657
611
0.0
40.0
62)
0.590
1,463
0.0
10.0
62)
0.657
407
0.0
6.8
48)
0.657
214
0.0
4.0
46
0.657
126
0.0
4.0
-48)x
0.657
126
Sched. Page Total 3,593
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 491 X 0.000 Watts/sgft x 3.413 Btuh[Watt = 0
Occupants 1.00 x 491 X 0 Btuh/occ. / 20,000 sqft/occ. = 0
Receptacle 1.00 X 491 X 0.000 Watts/sgft x 3.413 Btuh[Watt = 0
Process 1.00 x 491 x 0.000 Watts/sqft x 3.413 BtuhfWatt = 0
Infiltration: [ 1_00 x _ 1.064 . x 491 x _ 9.00 x 0.00 / 60] 38 = 0
Schedule Air Sensible Area Ceiling Height ACH /-\T-
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,270
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 491 x 0 Btuhlocc. / 20,000 sgft/occ. = 0
Receptacle 1.00 x 491 x 0.000 Watts/sgft x 3.413 Btuh/VNatt = 0
Process 1.00 x 091 x 0.000 Watts/sqft x 1 3.41J, Btuh/Watt = 0
Infiltration: [ 1. 0 x _ 4,771 x 491 x 9.00 x C 0.00 / 60] 0.00000 = ��
Schedule Air Latent Area Ceiling r e ht ACH /-�Sw
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: " Page: 15 of 15