Loading...
05-2951 (AR)C.vi�,_ P.O. BOX 1504 4 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: . 05=0000295i`""~ Owner: Property Address: 79965 DOUBLE EAGLE WY Dave ,White APN: 775-250-004- - - 79-965 Double Eagle Way Application description: ADDITION - RESIDENTIAL LA QUINTA, CA 92253 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 39673 1 Contractor: Applicant: Architect or Engineer: EDWARDS CONSTRUCTION, BOB 51455 DESERT CLUB DRIVE LA QUINTA, CA 92253 (760)777-8202 Lic. No.: 684857 LICENSED CONTRACTOR'S DECLARATION .- I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Sec '"on 000) f Division 3 of th 'ness n s nal? Code, my License is in full force and effect. L' enseji lass: /B� License : 684857 Date:�1 "'� Contractor: 1_ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERM[T VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/13/05 IF WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier VIRGINIA SURETY Policy Number 00500027012 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I,sjeCRr be e s Wmwith orkers' compensation provisi sof Section +I J337700 of the Labo d 1 all f hwitthose provisi s. Date:"W Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. - Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of s ermit, or cessation of work for 180 days will subject permit to cancellation. I certify tj�atlve read this application and state th thea ove i o is r I agree to comply with all city nd #ordinances and state laws relating to uildi gons ctio re uthorize representatives is enter upon the above-mentioned pro rt r in's a 'o p rposes. Date �` f�J/ Signature (Applicant or Agent): Application Number . . . . . 05-00002951 Permit BUILDING PERMIT Additional desc . Permit Fee . . . . 349.50 Plan Check Fee 227.18 Issue Date Valuation . . . . 39673 Expiration Date 3/12/06 Qty Unit Charge Per Extension BASE FEE 252.00 15.00 6.5000 ---------------------------------------------------------------------------- THOU BLDG 25,001-50,000 97.50 Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 32.19 Plan Check Fee 8.05 Issue Date . . . . Valuation 0 Expiration Date 3/12/06 Qty Unit Charge Per Extension BASE FEE 15.00 491.00 .0350 ---------------------------------------------------------------------------- ELEC NEW RES - 1 OR 2 FAMILY 17.19 Permit GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/12/06 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . . Permit Fee . . . . 39.50 Plan Check Fee 9.88 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/12/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH VENT FAN 6.50 Permit . . PLUMBING Additional desc . . LQPERMIT Application Number . . . . . 05-00002951 Permit . . . . . . PLUMBING Permit Fee . . . . 42.00 Plan'Check Fee 10.50 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/12/06 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 6.0000 EA PLB FIXTURE 24.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 ------------------------------------------------------------------ Special Notes and Comments ---------- Casita Addition (491 sqft) MUP 05-559 ---------------------------------------------------------------------------- Other Fees . . . . . . ART IN PUBLIC PLACES -RES 20.00 ENERGY REVIEW FEE 22.72 STRONG MOTION (SMI) - RES 3.96 Fee summary Charged ----------------- Paid Credited Due ---------- Permit Fee Total 478.19 ------------------------------ .00 .00 478.19 Plan -Check Total 255.61 .00 .00 255:61 Other Fee Total 46.68 .00 .00 46.68 Grand Total 780.48 .00 .00 780.48 1% LQPERMIT i It Remit # Project Address: A. P. Number: -77250 C Legal Description: Lc�4 Contractor: Address-. 1:17 City, ST, Zip: QI Telephone: -7—/—"7 `' C O State Lic. # , Designer: � Address: 4 ' .. 2 City';ST, Zip: Obs Tele fi one: 7 P "[ C> State laic #: Name of Contact Person: Telcnhon'c # of Contact Person: # Submittal Rcq'd Plan Sets Structural Calcs. Truss Calcs. 8/ Titic 2'4 Calcs. . Flood ptaiit plan Grading plan Subcontactor List City of D Quit] Building 8t Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Owner's Name:"� X Address: ?C) - S City, ST, Zip: LOA" / Telephone:. ac,45 Project Description: Lic. #: Construction Type: Occu P ancv: • airPro1eet n Demo Ne Add'n Al to RcP Sq. Ft.: #Stories: #Units;. – � � Project: Grading Estimated Value of ''` Revien eadv for corrections/issue APPLICANT: DO NOT WRITE BELOW THIS LINE Planning Approval Recd TRACMNC PERMIT FEES Plan Check submitted �g Item Amount Reviewed, ready for corrections $ 8 Plan Check Deposit Called Contact Person 8 Plan Chick Balance Plans picked up'F Construction Q� Q Plans resubmitted �j v/p2-/ Dtechanical 2"' Review, ready for corrections ssucQ!!F i Electrical C211ed Contact Person 0011 Plumbing Grant Deed Plans picked, up II.O.A. Approval Ylans.resubmitttd Grading IN IIOUSE:- ''` Revien eadv for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees — f L Tota t Permit r ecs •'. /3 CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road BERMUDA DUNES O RANCHO MIRAGE CJ Date 11/28/05 La Quinta, CA 92253 r INDIAN WELLS DESERT No. 27879 (760) 771-8515 Z.� PALM LA QUINTA Zf!-��INDIO y� 0 Owner Dave White APN # 775-250-004 Address 79-965 Double Eagle Way Jurisdiction La Quinta City La Quinta Zip 92253 Permit # Tract # Study Area Type Residential Addition No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 79965 Double Eagle Way 491 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments Attached Casita - Exempt At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 491 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Bob Edwards Check No. Name on the check Telephone Funding Exempt By Dr. Doris Wilson Superintendent Fee collected /exempted by Sharon Signature ilvrey 1 Payment Recd µ w $0.00 7 7, -- _ ?, river/Wd& r •l , NOTICE: Pursuant to Government Code Section 66020(d)(1), this AUAerve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy -Applicant/Receipt Copy -Accounting CONCORDE *CONSULTING CROUP, INC. ENGINEEEKING & CONSTRUCTION MANAGEMENT 3305 C—AMINO DEL RIO SOUTH, # 350 SAN DIEGO, CA 92108 PF-(: (61.9) 516-337"1 FAX: (619) 316-3388 NIFMORANDUM/FAX COVER SHEET TO: i"WOM: Robert Pitchford KRIPA FAX W"NIBL'R. NO. (1): NI OW; NIA181,12: `:F.NDEJ)lls 10IT"A! NUM141; P. iR iL +0141 T a C A I I TA 17 X k.,'K("Tt'-NT X PDR Rt*,.\;(I-'-):' X l'jJ%A" il--' X, W " I Y D lu.-cycm., WE FLWE RE-VIEWEl') T141". 'TRU'SS Dp AWT NGS PROVIDED FORTHIS PROJECT. A WE FIND -111ATTHE TRUSS DIKAWINGS ARE,. IN, GpF.NE-'RAl. CONFORMANCE WITH DESIGN INTENTANI', (*()Ns*rRU(-"1'1('.)N L)"*'(AJ'NMFN'FS PLEASE CALL IF 'YOU I T.rVvF'ANY Q�.:ESTIONS, flANKS KRIPANARAY.NAN - REPORTTM ESR -1 334 ' Issued June 1, 2004 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. BusineseVRegional OffiOe a 5350 Workmen Mil Road, WMer, California 90601 ■ (562) 69DOW Regional Office ■ 900 Montclair Road, Suite A, Birmingham, Alabama 35213 ■ (205) 599.9800 www.icc-es.org Regional Office ■ 4051 West Flossnim Road, Country Club HUs, Illinois 60478 ■ (708) 7992305 DIVISION: 08—DOORS AND WINDOWS Section: 08620—Unit Skylights REPORT HOLDER: SOLATUBE INTERNATIONAL, INC. 2210 OAK RIDGE WAY VISTA, CALIFORNIA 92081-8341 (760)597-4400 www.solatube.com Info®solatube.com EVALUATION SUBJECT: SOLATUBE TUBULAR SKYLIGHTS 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2000 International Building Code® (IBC) ■ 2000 International Residential CodeP (IRC) ■ 1997 Uniform Building Code TM (UBC) Propertles evaluated: ■ Durability ■ Structural ■ Weather resistance 2.0 USES The Solatube skylights described in this report are plastic - glazed tubular skylights complying with Chapters 24 and 26 of the IBC and UBC and Section 8308.6 of the IRC. 3.0 DESCRIPTION Solatube skylights are tubular skylights consisting of a clear acrylic light -transmitting dome with an internal curved reflector; a roof -mounted support base (flashing); an upper - tube -supporting element (dome -ring); reflective light - conducting tubing of either adjustable 0 -to -30 -degree elbows, 0 -to -90 degree elbows, and/or straight extension tubes; a lower -tube -supporting element (either ceiling ring or round -to - square -transition); and a ceiling -mounted light -diffusing assembly (diffuser). The Solatube skylights are available in 10-, 14- or 21 -inch -diameter (254, 256 or 533 mm) models. See Figure 1 and Table 1 of this report for additional details. 4.0 INSTALLATION 4.1 General: The Solatube skylights are prepackaged for field installation, with all components, attachments, and instructions in the shipping carton. A 10.5-,14.5- or 22 -inch -diameter (267, 368 or 559 mm) round hole, for the 10-, 14- and 21 -inch -diameter (254, 256 or 533 mm) skylights, respectively, shall be cut in the roof sheathing and ceiling below the attic space. The skylight support base shall be attached to the roof sheathing using eight No. 10 by 2 -inch -long (51 mm) stainless steel or dacrotized-finish steel sheet metal screws for the 10- and 14 - inch (254 and 256 mm) units, and sixteen screws for the 21 - inch (533 mm) unit. A felt or foam weather seal shall be adhered to the top edge of the skylight support base. The reflective top tube with attached dome ring shall then be inserted into the skylight support base opening. A curved reflector shall be mounted inside the dome. The dome shall be secured to the support base using four No. 8 by 3/4 inch - long (19 mm) stainless steel or dacrotized-finish steel pan or truss head sheet metal screws for the 10- and 14 -inch (254 and 256 mm) units, and six No. 8 by 3/4 inch -long (19 mm) screws for the 21 -inch (533 mm) unit. The 10- and 14 -inch (254 and 256 mm) units terminate at the ceiling into the ceiling ring installed, using four No. 6 by 1,5/, -inch -long (41 mm) corrosion resistant, bugle head, drywall screws and four plastic self-locking anchors or four plastic anchors only. See Figure 2 of this report for additional details. The 21 -inch (533 mm) unit terminates at the ceiling into a square -to -round plastic transition box set Into the framework on a suspended T -bar ceiling system, or is installed into a gypsum ceiling using four No. 6 by 15/, -inch -long (41 mm) corrosion resistant, bugle head drywall screws. See Figure 6 of this report for additional details. The 10- and 14 -inch -diameter (254 and 256 mm) light diffusers shall be secured onto the ABS ceiling ring by means of a one-eighth clockwise turn or by means of four plastic diffuser clips. The 21 -inch (533 mm) light diffuser shall be secured onto the square -to -round transition box by means of four diffuser latches or, for the 21 -inch (533 mm) open ceiling light diffuser, by means of four plastic diffuser clips. The lowest edge of the support base turret opening shall be at least 4 inches (102 mm) above the plane of the roof covering. This may be accomplished with installation of the optional Solatube 2 -inch -high (51 mm) galvanized or aluminized -steel turret extension. See Figure 3 of this report for additional details. The 4 -inch (102 mm) clearance requirement and the turret extension are not required on roofs of Group R, Division 3 (UBC) or Group R-3 (IBC), occupancy with a minimum slope of 3:12 (25%). Where a Class A, B or C roof covering is required, skylight dome edges shall be protected with the application of galvanized or aluminized steel, dome -edge protective rings, as shown in Figure 4 of this report, with the exception of the 21 -inch (533 mm) unit with 8 -Inch- (203 mm) or 11 -inch -high (279 mm) flashing, or any model with curb -mount flashing on curbs a minimum of 8 inches (203 mm) high. 4.2 Tile Roofs: For installation on a tile roof, a "dead -soft" 0.020 -inch -thick (0.51 mm) pleated aluminum sheet shall be used as malleable counter -flashing. After the appropriately sized hole for the 10- or 14 -inch (254 and 256 mm) Solatube skylight is t1REPCRTS'-are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, Inc., express or implied, as to any finding or other matter in this report or as to any product covered by the report Copyright 0 2004 Page 1 of 5 Page2 of 5 ESR -1334 cut in the roof sheathing, a metal base flashing shall be placed over the hole and secured in place using eight No. 10 by 2 -inch -long (51 mm) stainless steel or dacrotized-finish steel panhead sheet metal screws. See Figure 5 of this report for additional details. Tiles surrounding the flashing are cut according to the profile of the flashing, with a maximum clearance of /2 inch (12.7 mm) from the flashing. The pleated aluminum sheet, with a circular hole cut in the centerto match the flashing, shall be placed over the flashing. A galvanized or aluminized steel turret extension ring shall be placed over the opening of the base flashing, sandwiching the aluminum sheet between the flashing and turret extension ring. The aluminum sheet shall then be secured to the top of the tiles in the course below using non -alkaline and non -acidic tile mastic. The remaining sheet shall be tucked under the tiles in the upper course. When installing the system with high-profile tiles, the upper and side edges of the pleated aluminum shall be bent up to form a "bird stop" and water seal under the upper course tiles and surrounding field tiles. 4.3 Allowable Loads: The allowable positive and negative loads for the 10- and 14 - inch -diameter (254 and 356 mm) skylights is 100 psf (4.79 kPa), and 35 psf (1.67 kPa) for the 21 -inch -diameter (533 mm) skylight. 5.0 CONDITIONS OF USE The Solatube skylights described in this report comply with, or are suitable alternatives to what is specified in, those codes specifically listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation shall be in accordance with this report, Section 2405 of the IBC, Section R308.6 of the IRC and Sections 2409 and 2603.7 of the UBC, as applicable, and the manufacturer's published installation instructions. In the event of a conflict between this report and the manufacturer's published installation instructions, this report shall govern. 5.2 The maximum positive and negative loads shall be as described in Section 4.3 of this report. 5.3 The use of the skylights as a component of fire - resistance -rated assemblies is outside the scope of this report. 6.0 EVIDENCE SUBMITTED 6.1 Manufacturer's published installation instructions. 6.2 Data in accordance with the ICC -ES Acceptance Criteria for Plastic Skylights (AC16), dated October 2003. 6.3 A quality control manual. 7.0 IDENTIFICATION Solatube skylight components shall be packaged in boxes bearing the Solatube name and address and the evaluation report number (ESR -1334). Additionally, each skylight shall have a permanent label, conspicuously located, that bears the Solatube name and address, the evaluation report number, the plastic classification (CC -2) and the thickness of the plastic glazing material prior to forming. The 21 -inch - diameter (533 mm) skylight shall also have a safety label applied to each unit, warning of the risk of fall. TABLE 1—SOLATUBE SKYLIGHT MATERIAL COMPONENTS COMPONENTS SKYLIGHT DIAMETER 10 -INCH 14 -INCH 21 -INCH Dome—Atofina, Plexiglas DR 101 acrylic, 0.125 Inch thick, CC -2. See ICC -ES evaluation report ER -1084 X X Dome—Atofina, Plexiglas DR 101 acrylic, 0.143 inch thick, CC -2. See ICC -ES evaluation report ER -1084 X Support base—Galvanized or aluminized steel, 0.030 inch thick X X X Turret extension—Galvanized or aluminized steel (0.032 inch thick) X Turret extension ring—Galvanized or aluminized steel (0.030 inch thick) X X Square -to -round transition lower tube supporting element—Polypropylene, PVC or ABS plastic (0.060 inch thick) X Dome edge protective ring—Galvanized or aluminlzed steel (0.040 Inch thick) X X X Tile roof kit (0.020 -inch -thick, dead soft, pleated aluminum sheet) X X Aluminum reflective tube, 0.020 inch thick (polished) X X X Light diffuser—Ac ic, 0.100 inch thick, CC2 X X X For SI: 1 Inch = 25.4 mm. • ,Page 3 of 5 ESR -1334 Minch 14 -inch FIGURE 1—SOLATUBE 10-, 14 AND 21 -INCH UNITS 21" UNIT n A of ft(W s6. ms +e. PwwPs e a,ma31"s %. cccft zco ►eco Pnuws "S NO C omaft ft"m mmoyscam w. FIGURE 2—DETAILED DESCRIPTION OF 10 -INCH SOLATUBE ..Page 4 of 5 ESR -1334 FIGURE 3—TURRET EXTENSION l .,�,:._•�---".fig 16 UNIT FIGURE 4-10- AND 14 -INCH SOLATUBE DOME RING LIFMNO. OIY. PARI NO. DISCRIFFICH 1 1 MSE RAWW. 1 OCMFD 7 F61N30f1sumfoliTu J 1 =%l MG PLASTIC A 1 Dow Pt/WIC 6 12 60 FFLF PA Cl SCREW siILLCIACROIDFD VIEW slfill. CACROMD e 1 11.9E FOPAWU F Rm— FLA IWN V1 MLi ADPAWAPLEA110£FIFFI 0 0 C M4 FIGURE 5—TILE ROOF INSTALLATION PROCEDURE • - page 5 of 5 ESR -1334 Ir SEV fL^sK*G top MUMMY 0 K CEUVO IOtt0w /S$EVA:Y FIGURE 6—TYPICAL INSTALLATION OF 21 -INCH UNIT (INCLUDING DOME RING) TITLE 24 REPORT Title 24 Report for: Mr. & Mrs. Dave White-Casita 79-965 Double Eagle La Quinta, Ca 92253 J*CPar.A*SP/ Project Designer: Robert A Pitchford, Design & Drafting 41-625 Eclectic, #A2 Palm Desert, Ca 92260 (7.60) 346-2856 Report Prepared By: Tim Scott H & H Air Conditioning 74-991 Joni Drive #20 Palm Desert, CA 92260-2043 (760) 340-3088 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCT N DA /1Z/L 13Y Job Number: Date: 8/19/05 i The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533 A TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary.,., HVAC System Heating and Coolingloads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 6 8 12 13 14 15 EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533 1 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Mr. & Mrs. Dave White-Casita 8/19/05 ro/ec Title a e 79-965 Double Eagle La Qulnta vro/ec1 Aaaress H & H Air Conditioning (760) 340-3088 Documentation Autnor j a ep one Computer Performance 15 Building ermi Plan Check / Date Field ec a e Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: Total Conditioned Slab Area: Building Type: (check one or more) ® Single Family Detached ❑ Single Family Attached ❑ Multi -Family 491 ft2 Average Ceiling Height: 9.0 ft 491 ft2 ❑ Addition ❑ Existing Building ❑ Existing Plus Addition Front Orientation: (Southwest) 225 deg Floor Construction Type: FX -1 Slab Floor Number of Dwelling Units: 1.00 Number of Stories: BUILDING SHELL INSULATION Component Type R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) Slab On Grade Slab On Grade FENESTRATION ❑ Raised Floor Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) Wood 0.028 Exterior Roof Wood 0.059 Exterior Wall n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Skylight 0.5 0.80 0.39 None ❑ X❑ ❑ x❑ Right (Southeast) 15.0 0.72 0.59 Bug Screen ❑ N El NFront (Southwest) 25.0 0.87 0.59 Bug Screen ❑X❑ ❑X❑ Front (Southwest) 40.0 0.55 0.53 Bug Screen ❑ x❑ ❑ a Left (Northwest) 14.8 0.72 0.59 Bug Screen ❑ x❑ ❑ x❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1:1 El 1:1 El Run Initiation Time: 08/17/05 09:07:59 Run Code: 1124294879 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:3 of 15 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Mr. & Mrs. Dave White-Casita 8/19/05 rojec t e a e HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Split Heat Pump 7.30 HSPF Ducts in Attic 4.2 Setback HVAC -1 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location heat pump, evap; cooling) (SEER) (attic, etc.) Duct Thermostat Location / R -Value Type Comments Split Heat Pump 11.0 SEER Ducts in Attic 4.2 WATER HEATING SYSTEMS Rated 1 Water Heater Water Heater Distribution # in Input System Name Type Type Syst. Btu/hr A.O. Smith FSG -30-222 Small Gas Standard 1 32,000 Setback HVAC -1 Tank .Energy Fact' 1 External Cap. or Recovery Standby Tank Insul. (gal) Efficiency Loss (%) R -Value 30 0.62 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm Address: Robert A Pitchford, Design & Drafting 41-625 Eclectic, #A2 Name: Title/Firm Address: Tim Scott H & H Air Conditioning 74-991 Joni Drive #20 Palm Desert, Ca 92260 Palm Desert, CA 92260-2043 Telephone: Telephone: (7 0) 340-3101,88 Lic. #: p� gyl �/0 s gna ure) ( te) (signature) (date) nforcement gency Name: Title/Firm: Address: Telephone: signature/stamp (date) Run Initiation Time: 08/17/05 09:07:59 Run Code: 1124294879 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:4 of 15 Certificate of Compliance: Residential (Addendum) CF -1 R Mr. & Mrs. Dave White-Casita 8/19/05 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies . _ , .. , .... r .. ,..�.... ... ......,. Plan Field The HVAC System "HVAC -1" includes credit fora Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. an Field e System includes Retrigerant Charge and Airflow Credit (ora certified HERS rater must provicle verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. un nitlatlonTime: un Code: 1124294879 EnergyPro 3.1 By Energysoft User Number: 5533 Job Number: Page:5 of 15 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION 'Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ®'§150(a): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ®"§150(c): not apply to exterior mass walls). ❑ ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. ® §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. Ej§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ® § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. 150(e): Installation Fireplaces, § of Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ®§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ® §150(i): Setback thermostat on all applicable heating and/or cooling systems. ® §1506): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. . 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:6 of 15 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) CU'§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. (� § 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118 (f): Cool Roof material meet specified criteria I Lighting Measures §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for I general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. JX] I §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3,1 By EnergySoft User Number: 5533 Job Number: Page:7 of 15� Computer Method Summary (Part 1 of 3) C -2R Mr. & Mrs. Dave White-Casita 8/19/05 -Project T li -Date 79-965 Double Eagle La Quinta -Project Ad- ress BuilaingPe�mif H & H Air Conditioning (760) 340-3088 P>an check/Date -Documents iAu ofd a ep one Computer Performance 15 Field C eh c�C/Da e -Compliance Method -(Package or Compu er Climate one Source Energy Use (kBtu/sf-yr) Space Heating Space Cooling Domestic Hot Water Totals Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: Design 4.11 57.66 38.19 99.96 BUILDING ZONE INFORMATION Zone Name Proposed Design 3.44 65.25 30.78 99.47 491 Single Fam Detached (Southwest) 225 deg 1.00 1 Compliance Margin 0.67 -7.59 7.41 0.49- 491 .49 X❑ Slab Floor Floor Construction Type: ❑ Raised Floor Total Fenestration Area: 19.4% Total Conditioned Volume: 4,419 Slab Floor Area: 491 # of Floor Area Volume Units Zone Type HVAC -1 491 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Roof _ _ 490 0.028 0 20 Wall 180 0.059 45 90 Wall 201 0.059 135 90 Wall 115 0.059 225 90 Wall 201 0.059 315 90 Som Gains Y/N 4,419 1.00 Conditioned Form 3 Reference R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Casita Casita Casita Casita Casita Thermostat Vent Type Hgt. Area Setback 2 n/a Location / Comments Run Initiation Time: 08/17/05 09:07:59 Run Code: 1124294879 —� EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:8 of 15 Computer Method Summary (Part 2 of 3) C -2R Mr. & Mrs. Dave White-Casita 8/19/05 Project Title -Date Ll- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 1 Skylight Left North 0.5 0.800 0.39 0 20 Double Metal Tinted Default Casita 2 Window Right (Southeast) 7.0 0.720 0.59 135 90 Double Metal Tinted Default Casita 3 Window Right (Southeast) 4.0 0.720 0.59 135 90 Double Metal Tinted Default Casita _ 4 Window Right (Southeast) 4.0 0.720 0.59 135 90 Double Metal Tinted Default Casita _ 5 Window Front (Southwest) 15.0 0.870 0.59 225 90 Double Metal Tinted Default Casita _ 6 Window Front (Southwest) 40.0 0.550 0.53 225 90 Double NonMtl Tinted Default Casita 7 Window Front (Southwest) 10.0 0.870 0.59 225 90 Double Metal Tinted Default Casita 8 Window Left (Northwest) 6.8 0.720 0.59 315 90 Double Metal Tinted Default Casita 9 Window Left (Northwest) 4.0 0.720 0.59 315 90 Double Metal Tinted Default Casita 10 Window Left (Northwest) 4.0 0.720 0.59 315 90 Double Metal Tinted Default Casita INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGCHgt. Wa- ten. Rgt: - xE t. RExt. -ist—Len. FIT. -Dist. Len. Rgi. 1—None 1-00 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8— Bug Screen 0:76- 9 Bug Screen 0.76 -- 10 Bug Screen 0.76 --- Run Initiation Time: 08/17/05 09:07:59 Run Code: 1124294879 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:9 of 15 Computer Method Summ rj'"� �`r""'' (Part 3 of 3) C -2R Mr. & Mrs. Dave White-Casita 8/19/05 -Project Trtle -Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. 'Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 65 0.76 0.0 0 Casita Slab Perimeter 23 0.76 0.0 0 Casita HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Split Heat Pump- 7.30 HSPF Ducts in Attic 4.2 Setback HVAC -1 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Heat Pump 11.0 SEER Ducts in Attic 4.2 Setback HVAC -1 WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution. # in Input Cap. . or Recovery Standby R -Value System Name Type TypeSyst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.O. Smith FSG -30-222 Small Gas Standard 1 32,000 30 0.62 n/a n/a 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS _ Run Initiation Time: 08/17/05 09:07:59 Run Code: 1124294879 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:10 of 15 Computer Method Summary (Addendum) C -2R Mr. & Mrs. Dave White-Casita 8/19/05 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies .....,................... y......Y ... ..w .ter.•.•.. . J•. -•..—•.v....1 . •. v•....—n I. a v...—... L—. The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. an ie ld e HVAC 5ySffM--RVAC--I-!nC—I—UaTS-Retrigerant Charge 5nd Airtlow Credit (ora certified HERS rater—m—u—sf—provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation I Ime: u8/17/u5 u9:u7:59 Run Code: 1124294879 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:11 of 15 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Mr. & Mrs. Dave White-Casita 8/19/05 SYSTEM NAME FLOOR AREA HVAC -1 491 Number of Systems 1 Heating System Output per System 22,600 Total Output (Btuh) 22,600 Output (Btuh/sqft) 46.0 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sqft) 48.9 Total Output (sgft/Ton) 245.5 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sqft) 1.63 Airflow (cfmrron) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 of 310� Outside Air 0 cfm 69.5 of 11.0 / 77.6 of 310 OutsideA 0 cfm 74.5/60.8 of 69.5 of 69.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 404 8,270 529 9,223 0 413 461 0 0 a 0 0 0 0 0 0 413 461 9,097]:::::::0 10,146 HVAC EQUIPMENT SELECTION CARRIER 38QR024C31 17,209 2,839 14,864 Total Adjusted System Output 17,209 2,839 14,864 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am earn Temperatures at Time of Heating ea 86.9 of Su I Air D t Supply Fan Heating Coil 800 cfm 74.5/60.8OF 74.5/60.8OF Roti irn Air n, irtr 54.3 / 53.2 of Supply Fan Cooling Coil 800 cfm oollnq tea �, Return Air Ducts Y pp y uc s 86.4 of ROOMS 70.0 of Supply Air Ducts 54.8 / 53.4 of 46.4% R.H. i ROOMS-] 74.0 / 60.6 of EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: PageA2 of 15 ROOM LOAD SUMMARY PROJECT NAME Mr. & Mrs. Dave White-Casita DATE 8/19/05 SYSTEM NAME HVAC -1 FLOOR AREA 491 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Casita asi a 1 404 8,270 0 404 8,270 0 529 9,223 PAGE TOTAL 1404 8,2701 0 5291 9,223 TOTAL 404 8,270 529 9,223 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:13 of 15 ROOM HEATING PEAK LOADS R-38 Roof (R.38.2x14.16) Double Metal Tinted Default R-21 Wall (W.21.2x6.16 Double Metal Tinted Default Double Metal Tinted Default Double NonMtl Tinted Default Slab -On -Grade 490.5 X X X X X X X x X X x X X X X X X X X X X X X x X X X X X X X X X X X X X X X 0.0280 X X X X X x X x X x x X X X X X X X X X X X X x X X X X X X X X X X X X X X X Project Title Mr. & Mrs. Dave White-Casita = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 604 Date 18/19/05 0.8000 Room Information Design Conditions 697.2 0.0592 Room Name Floor Area Indoor Dry Bulb Temperature I Casita 491 70 OF Time of Peak Outdoor Dry Bulb Temperature 0.7200 ,tan 12 am 26°F Conduction Area U -Value AT °F Btu/hr R-38 Roof (R.38.2x14.16) Double Metal Tinted Default R-21 Wall (W.21.2x6.16 Double Metal Tinted Default Double Metal Tinted Default Double NonMtl Tinted Default Slab -On -Grade 490.5 X X X X X X X x X X x X X X X X X X X X X X X x X X X X X X X X X X X X X X X 0.0280 X X X X X x X x X x x X X X X X X X X X X X X x X X X X X X X X X X X X X X X 44.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 604 0.5 0.8000 44.0 18 697.2 0.0592 44.0 1,816 29.8 0.7200 44.0 944 25.0 0.8700 44.0 957 40.0 0.5500 44.0 968 perimeter = 88.0 44.5 3,916 _ items snown warn an asrensK t I genote conaucuon rnrougn an interior surtace to anotner room. Page Total: 9,223 Infiltration: I 1.00 x 1T064x 491 x 9.00 x 0.00 160 x _ LSch—mule Ate Sensible Area Ceiling eight ACH Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,223 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 14 of 15 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Mr. & Mrs. Dave White-Casita 8/19/05 Project Title Date Room Name Casita Design Indoor Dry Bulb Temperature: 740F Design Outdoor Dry Bulb Temperature: 112°F Design Temperature Difference: 380F Conduction Area U -Value DETD' Btu/hr X (Skylight) 55.0 = 755 X Window 38.0 = 15 X (Southwest) 34.6 = 1,428 X 4.0 38.0 = 815 X 4.0 38.0 = 826 X 15.0 38.0 = 836 X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 4,677 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Skylight_ (Skylight) Window (Southeast) Window (Southeast) Window (Southeast) Window (Southwest) Window (Southwest) Window Window Window (Window (Southwest) (Northwest) (Northwest) (Northwest) 0.0 x X x x X x x x x X 1 s + 15 + 15 + 151+ 15 + 15 + 15 + 15 + 15 + 1 + 0.5 X X x X X X X x X X 152) X X X X X X x 0.448 = = = = = = = = __ = 34 0.0 7.0 62)x 0.657 285 0.0 4.0 62) 0.657 163 0.0 4.0 62) 0.657 163 0.0 15.0 62)x 0.657 611 0.0 40.0 62) 0.590 1,463 0.0 10.0 62) 0.657 407 0.0 6.8 48) 0.657 214 0.0 4.0 46 0.657 126 0.0 4.0 -48)x 0.657 126 Sched. Page Total 3,593 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 491 X 0.000 Watts/sgft x 3.413 Btuh[Watt = 0 Occupants 1.00 x 491 X 0 Btuh/occ. / 20,000 sqft/occ. = 0 Receptacle 1.00 X 491 X 0.000 Watts/sgft x 3.413 Btuh[Watt = 0 Process 1.00 x 491 x 0.000 Watts/sqft x 3.413 BtuhfWatt = 0 Infiltration: [ 1_00 x _ 1.064 . x 491 x _ 9.00 x 0.00 / 60] 38 = 0 Schedule Air Sensible Area Ceiling Height ACH /-\T- Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,270 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 491 x 0 Btuhlocc. / 20,000 sgft/occ. = 0 Receptacle 1.00 x 491 x 0.000 Watts/sgft x 3.413 Btuh/VNatt = 0 Process 1.00 x 091 x 0.000 Watts/sqft x 1 3.41J, Btuh/Watt = 0 Infiltration: [ 1. 0 x _ 4,771 x 491 x 9.00 x C 0.00 / 60] 0.00000 = �� Schedule Air Latent Area Ceiling r e ht ACH /-�Sw Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: " Page: 15 of 15