Loading...
07-0377 (AR),r w P.P. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 07-00000377 Property Address:. 79975 DOUBLE EAGLE WY APN: 775-250-003- - - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 24805 Applicant: Architect or Engineer: b� - - P 11'r ------------------ LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. �License Class: License No.: - - - - - - - - - - - - - - - V'�— C OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any a plicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: I 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will.have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.0.4r this reason Date: S-04"'0-7 Owner: CONSTRUCTION LENDING AGENCY — I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.I. Lender's Name: _ Lender's Address: LQPERA11T VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/10/07 Owner: MORROW ROBERT D 13215 C8 SE MILL PL NO 538 VANCOUVER, WA 98684 Other struct info . . C Contractor: D Owner MAY 0 4 2001 DITION 20'01% Q6F—LA Lic. No.: ---------- r ---- CIUAWr-P ----------------------------------------------- WORKER'S COMPENSATION DECLARATION" I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier NO Policy Number E FOOTAGE I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should ecome subject to the workers' compensation provisions of Section 3700 of the Labor Co shall forth iyacQmply with those provisions. Dater Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date ofissuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to b onstruction, and hereby authorize representatives of this co my t enter upon the above-mentioned71&ffg.�rcmspectirp,Date: "7 Signature (Applicant or Ag Application Number . . . . . 07-00000377 Permit BUILDING PERMIT Additional desc . Permit Fee . . . . 252.00 Plan Check Fee 163.80 Issue Date . . . . Valuation . . . . 24805 Expiration Date 10/07/07 Qty Unit Charge Per Extension BASE FEE 45.00 23.00 9.0000 ---------------------------------------------------------=------------------- THOU BLDG 2,001-25,000 207.00 Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 25.75 Plan Check Fee 6.44' Issue Date . . . . Valuation . . . . 0 Expiration Date 10/07/07 Qty Unit Charge Per Extension BASE FEE 15.00 307.00 .0350 ---------------------------------------------------------------------------- ELEC NEW RES - 1 OR 2 -FAMILY 10.75 Permit GRADING PERMIT Additional desc . Permit Fee . . . . 15.-00 Plan Check Fee .00 Issue Date . . . Valuation . . . . 0 Expiration Date 10/07/07 Qty Unit Charge Per Extension - ---------------------------- BASE FEE ---------- ------------------------------------ 15.00 Permit . . MECHANICAL Additional desc . Permit Fee . . . 24.00 Plan Check Fee 6.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 10/07/07 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 ---------------------------------------------------------------------------- Special Notes and Comments ADDITION TO EXISTING CASITA 307 SQ. FT. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ENERGY REVIEW FEE 16.38 STRONG MOTION (SMI) - RES 2.48 LQPERMIT Application Number Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total LQPERMIT Charged 316.75 176.24 18.86 511.85 07-00000377 Paid Credited .00 .00 .00 .00 .00 .00 .00 .00 Due 316.75 176.24 18.86 511.85 Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 Project Name: Robert Morrow Owner's Name: Robert Morrow This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK N: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 11620) Project Address: 79975 Double Eagle Way, La Quinta Project Description: Room Addition 05/04/07 Phone No. APN: 775-250-003 Tract #: Lot #'s: Residential XX Commercial_ Industrial Total Square Feet of Building Area: 307 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: 05/04/07 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 307 sq. ft. Amount per Sq.Ft. $ 0.00 Amount Collected $ 0.00 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: Maria L. Angulo, Facilities Secretary Signature: Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, require§ that this bistrict provide (1)'a written notice to the prQjcct appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. %l ol'comphancc form tables'( I USELIOc 1/16/03 T T,44t 4 4 49�kz Building & Safety Department 78-495 Calle Tampico PO Box 1504 La Quinta, CA 92253 (760) 777-7012 voice — (760) 777-7011 fax CERTIFICATION OF BUILDING AREA STREET ADDRESS OF JOB: 79-975 DOUBLE EAGLE WAY APN: 775-250-003 DESCRIPTION OF WORK: ADDITION SQUARE FOOTAGE: 307 SQ. FT. OWNER'S NAME: ROBERT MORROW Coachella Valley Unified School District . 83-733 Avenue 55 P 0 Box 847. Thermal, CA 92274 (760) 398 5909 Desert Sands Unified School District 47-950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 CITY OF Iik QvINTA BUILDING & SAFETY DEPT. APPROVED FV,, OR CONS 4flva DATF Please Note: This Letter Verifies Conditioned Square Footage. Please call your School District to Verify . School Fees, Requirement for Cashiers Check or Money Order and Hours of Operation. For questions regarding this letter, please call. Ed Randall, Counter Technician (760) 777-7012 TELEPHONE (760) 777-7012 FAX(760)777-7011 OWNERBUILDER INFORMATION Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified. For your protection you should be aware that as "Owner/Builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the City or County. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be aware of the following information for your benefit and protection: If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $200.00 or more for the entire project, and such persons are not.licensed as contractors or subcontractors, then you may be an employer. If you are an employer, you must register with the State and Federal Government as an employer and you are subject to several obligations include State and Federal income tax withholding, federal social .security taxes, worker's compensation insurance, disability insurance costs and unemployment compensation contributions. There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to worker's compensation insurance. J For more specific information about your obligations under Federal Law, contact the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contracts are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "Owner/Builder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contacting the Contractors' State License Board in your community or at 1020 N. Street, Sacramento, California 95814. Please complete and return the enclosed owner -builder verification form so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned. ' Very truly yours, CITY OF LA QUINTA _ DEPT. OF BUILDING AND SAFETY 78-495 Calle Tampico La Quinta, CA 92253 (760) 777-7012 FAX: (760) 777-7011 aAB?i4-� M M 4, O ER'S SIGNAT-URE/DATE I 79 ISO %Jou&-F E46 L,1F WAY PROPERTY ADDRESS a-7- 3-7-1 PERMIT NUMBER(S) Concorde Consulting Group, Inc Construction Management • Project Management • Architecture /Engineering • Development June 22, 2007 To: Robert Pitchford Pitchford Design RE: Casita Addition -- Morrow Residence" -79975 Double Eagle, La Quinta, California Robert: Thisnote is to confirm that the framing and nailing for the referenced project is in general conformance with construction documents and design intent. Please*call if you have any questions QPofEssioNg4 �o �PIPAIy,� `otic Yours truly, 1 54 r,130107 m p� EXP �s K. M. Kripanarayanan. S. E. * STSTRucNPOe��� Concorde Consulting Group, Inc qTF OF cP�``` 3505 Camino Del Rio South, #350 San Diego, CA 92108 Tel (619) 516-3377 Fax (619) 516-3388 3505 Camino Del Rio South, #350, San Diego, CA 92108. Ph: (619) 516-3377 Fax: (619) 516-3388 11 CITY OF LA QUINTA PLAN CHECK CORRECTION LIST Robert Pitchford 41-625 Eclectic, Suite A-2 Palm Desert; CA 92260 April 4, 2007 PLAN CHECK NO. 07-377 SECOND/FINAL CHECK ( Structural Review only) ADDRESS 79975 Double Eagle Way OCCUPANCY R -3/U-1 SCOPE OF WORK Addition TYPE -OF -CONST. V -N Office The submitted plans and specifications have been reviewed by the VCA CODE GROUP. In our professional opinion the plans are in substantial conformance with the building codes and regulations adopted by the CITY OF LA QUINTA and the State of California Amendment. APPROVAL FOR A BUILDING PERMIT IS HEREBY RECOMMENDED SUBJECT TO OBTAINING APPROVALS/CLEARANCES FROM ALL APPLICABLE CITY DEPARTMENTS, AGENCIES, AND ASSOCIATIONS. Plans checked by: Timothy Koutsouros, P.E. VCA CODE GROUP 2200 W Orangewood Ave, Ste 155 Orange, CA 92868 (714) 363-4700 ext. VCA File No. LQ -19423 1 Bin # City of La Quinta Building U Safety Division on P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # 3?7 Project Address: `7 aj79- Owner's Name: V C to" A. P. Number: —7 7 !mss OQ 3 Address: Legal Description: Tr 2 2 �"I City, ST, Zip: (,4 C!2 -s tAJT;& Contractor: Telephone: Address: Project Description: City, ST, Zip: / tom/ r� TO �7`-�-5TT)4% Telephone: State Lia # : City Lie.#: Designer (` t�Address4t bZl City, ST, Zip: RL"Telephone: -:34�`�S6 State Lie. #: Construction Type: Occupancy: Project type (circleone): New Add'n Alter Repair Demo Name of Contact Person: Sq. Ft.:0-7 # Stories:# Units: Telephone# of Contact Person: Estimated Value of Prc jec . ,2 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Reed TRACKING. PERMTT FEES 4� Plan Sets Plan Check submitted 2 Z. Item Amount a, Structural Coles. Reviewed, ready for corrections 121t Plan Check Deposit Truss Coles. Called Contact Personk\zln Plan Check Balance d— Energy Coles. Plans picked up 3 Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for correcd (Srssue Electrical Subcodtactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. ILO.A. Approval Plans resubmitted Grading IN HOUSE:- ''' Review, ready for correctionstissue Developer Impact Fee Planning Approval Called Contact Person A.LP.P. Pub. Wks. Appr Date of permit issue School Fees IYJR A 1J Total Permit Fees ala VC-&TUE 7-I1-4 ion- GMq-C--- +/&/c)7 )7 5172. A PPRP uRBcE TITLE 24 REPORT ' Title 24 Report for: Mr. & Mrs. Robert Morrow-Casita Addition 79-976 Double Eagle La Quinta, CA 92253 Project Designer: Robert A. Pitchford, Design & Drafting 41-625 Eclectic, #A-2 Palm Desert, CA 92260 (760) 346-2856 Report Prepared By: Tim Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 Job Number: Date: 1/12/2007 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONST /$CTION / DATE k ` (O 1 / 07 g �� o computer program has been used to perform the calculations summarized in this compliance report.-rHh9:program has approval and is the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.2 by EnergySoft Job Number: User Number: 6712 4 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 7 9 10 11 13 EnergyPro 4.2 by EnergySoft Job Number: User Number: 6712 1 'Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R Totals 191.62 Standard: Building Type: W Single Family ❑ Multi Family Building Front Orientation Fuel Type: 187.99 ❑ Addition [� Existing + Add/Alt (SW) 240 deg . Natural Gas 3.63 1.9% Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Fenestration: Average Ceiling Height: Area: 175 ft2 Avg. U: 0.79 Number of Dwelling Units: 1/12/2007 oject Title NUILDING ZONE INFORMATION # of Thermostat ne Name Floor Area Volume Date Project Address Building Permit # Sett Design & Title 24 (760) 200-4780 Documentation Author Telephone Plan Check/Date Fn _raVPro Compli nce Method 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 4.80 6.56 -1.76 Space Cooling 141.91 133.13 8.78 Fans 20.28 23.66 -3.39 Domestic Hot Water 24.64 24.64 0.00 Pumps 0.00 0.00 0.00 Totals 191.62 Standard: Building Type: W Single Family ❑ Multi Family Building Front Orientation Fuel Type: 187.99 ❑ Addition [� Existing + Add/Alt (SW) 240 deg . Natural Gas 3.63 1.9% Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Fenestration: Average Ceiling Height: Area: 175 ft2 Avg. U: 0.79 Number of Dwelling Units: Ratio: 25.8% Avg. SHGC: 0.67 Number of Stories: NUILDING ZONE INFORMATION # of Thermostat ne Name Floor Area Volume Units Zone Type Type 1 nn Conditioned Sethack HVAC: -1 67R X10 OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rnnf Wnnd ---m n 077 R-19 R-0 0 �_ 99 Wall Wood _ 153 0.110 R-11 R-0 0 _60 90 Wall Wood ---= 0.110 R-11 R-0 0 150 _90 Wall Wnnd _ a1 o 11n R-11 R-0 0 24n An Wall Wood _ 36 0.110 R-11 R-0 0 330 gn Wall Wnnd 135 0 110 R_11 R-0 0 330 gn Rnnf Wnnd 307 n n2g R_38 R_0 0 n 22 Wall Wnnd _ 105 n as R_91 R_n 0 sn g0 Wall Wnnd 44 0 069 X21 R-0 0 150 gQ Wall Wood 95 0.069 R-21 R-0.0 240 gn Wall Wnnd _ 194 n 069 R_91 R-0 0 lin An F 678 ft2 371 ft2 0 ft2 678 ft2 9.0 ft 1.00 1 Vent Hgt. Area —nla Gains Condition Y / N Status JA IV Reference Location / Comments ® ❑Fxisti 9 02-A1fid Existing Casita ® ❑Existing 09-A2 Exicting Casita ® ❑Existing 09-A2 Existi 9S:asita ® ❑Existing 09-A2 FxiSting Casita ® ❑Existing 09-A2 Exis in9sasita ® ❑Removed 09-A2 Fxist6n9 Casita ® ❑New 02-A2A Additinn ® El Ne, 09-A6 Additinn ® ❑New 09-A6 Addition ® ❑New 09-A6 Addition X ❑New 09-A6 Additinn F] F1 F-1 F1 r-1 F-1 F-1 F1 1-1 F1 ❑❑ F1 F-1 F1 F-1 ❑❑ ❑❑ ❑❑ ❑❑ F1 F1 1-1 El EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:3 of 14 I Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R r. & Mrs. Robert Morrow-Casita Addition ff oject Title 1/12/2007 Date FENESTRATION SURFACES # Type Area True Cond. U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Location/ Comments J_ Window Front (,SW1 24 Q 0.790 116_A 07 SIFRC 240 --U Existing Double Metal Clear Existing Casita 2 Window Front (SW) 24.0 0.790 116-A 0_79 NFRC 240 90 Existing Double Metal Clear Existing Casita 3 Window Front (SW) 24.0 0.790 116-A 0_79 NFRC 240 90 Existing Double Metal Clear Existing Casita 4 Window Rear (NE) 30.0 0.790 116-A 0.59 116-B 60 90 New Double Metal Tinted Addition 5 Window Right (SE) 24.0 0.790 116-A 0_59 116-B 150 90 New Double Metal Tinted Addition 6 Window Front (SW) 40.0 0.790 116-A 0_59 116-B 240 90 New Double Metal Tinted Addition L Window Left (NW) 4.5 0.79 11 6 -A -Q -U 116-B 330 90 New Double Metal Tinted Addition 8 Window Left (NW) 4.5 0.790 116-A 0.59 116-B 330 90 New Double Metal Tinted Addition 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1166. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 isBug Screen 0.76 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 73 None No Insulation 26-A1 Existing Existing Casita Slab Perimeter 60 None No Insulation 26-A1 New Addition Run Initiation Time: 01/12/0708:42:13 Run Code: 1168620133 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:4 of 14 'Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R .Mr. & Mrs. Robert Morrow-Casita Addition 1/12/2007 111111111111111111111111�oject Title Date AC Heating Minimum ` Cooling Minimum Condition Thermostat Location TvDe Eff Tvpe Eff Status Tvpe HVAC -1 Split Heat Pump 8.60 HSPF Split Heat Pump 14.0 SEER Altered Setback pre -altered for above Central Furnace 78% AFUE Split Air Conditioner 10.0 SEER Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC -1 Ducted Ducted Attic 4.2 Existing Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 Existing 0.57 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Control # HP Hot Water Piping Length (ft) Add 1/2" In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Enforcement Agency Name: Title/Firm: Address: Telephone: gnature) (date) Documentation Author Name: Tim Scott Title/Firm: Scott Design & Title 24 Address: 77085 Michigan Dr. Palm DesertCA 92211 Telephon 76 200-4 80 1 rzo (signs re) (date) I EnergvPro 4.2 by EneravSoft User Number: 6712 Job Number: Page:5 of 14 1 'Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Title 1/12/2007 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and. documentation submitted.. IThe Existing Roof "Roof' has a LI -Factor greater than the Table R3-11 CEC Default Vintage Values. Plan I Field HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -4R Plan I Field installation certificate. " incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on The Cooling System "Carrier 25HPA430/FX4CNF30" includes credit for a 11.6 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. I EnergyPro 4.2 by EnergvSoft User Number: 6712 Job Number: Paae:6 of 14 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit is documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. 0 DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. NIA DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑ ❑ e§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ N ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ f§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑X ❑ f§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox b. outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed. § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ a ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 0 ❑ ❑ ❑X ❑ ❑ 0 ❑ ❑ ❑ ❑ ❑ Eil ❑ ❑ o ❑ • ❑ ❑X ❑ ❑ a ❑ ❑ ❑ ❑ ❑ N ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ IEnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:7 of 14 . Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R 0 0 NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ X❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ X❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and ❑ ❑ ❑ support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause ❑ ❑ ❑ reductions in the cross-sectional area of the ducts. ❑ ® ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ ❑ Lighting Measures ❑ ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. ❑ ® ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, ❑ ® ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ X❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms luminaires less 70 ft) OR by dimmer OR ❑ ❑X ❑ shall be high efficacy (except closets than are controlled a switch are controlled by an occupant sensor that complies with Section 1) 9(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:8 of 14 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Mr. & Mrs. Robert Morrow-Casita Addition 1/12/2007 STEM NAME FLOOR AREA HVAC -1 678 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 11COILHTG.PEAK CFM I Sensiblel Latent I CFM I Sensible 739 20,587 659 703 17,764 at Time of Cooling 0 10.0 / 72.5 of 80.1 / 58.2 of 80.1 / 58.2 of 3,250 1,789 0 0 0 0 0 0 0 0 0 3,250 1 1,789 27,087F777;59 Carrier 25HPA430/FX4CNF30 23,210 0 Total Adjusted System Output 23,210 0 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm 18,737 18,737 Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 67.2 of 67.2 of 96.5 of Supply Air Ducts Outside Air - 0 cfm 93.7 of Supply Fan Heating Coil 600 cfm ROOMS 70.0 of 67.2 of i EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:9 of 14 b Return Air Ducts `Src TOOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 10.0 / 72.5 of 80.1 / 58.2 of 80.1 / 58.2 of 43.7 / 42.0 of Supply Air Ducts *0 Outside Air 0 cfm Supply Fan Cooling Coil 48.8 / 44.5 of 600 cfm ROOMS 29.5% R.H. 80.1/58.2 of 75.0 / 56.3 of Return Air Ducts EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:9 of 14 r L 4 �R'OOM LOAD SUMMARY PROJECT NAME DATE Mr. & Mrs. Robert Morrow-Casita Addition 1/12/2007 YSTEM NAME FLOOR AREA HVAC -1 678 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Existin Casita Existing Casita 1 384 10,702 323 384 10,702 323 375 9,466 Addition Addition 1 355 9,885 336 355 9,885 336 328 8,298 r PAGE TOTAL 739 20,587 659 703 17,764 TOTAL 1 739 20,587 659 703 17,764 EnergyPro By EnergySoft User Number: User Job Number: Page: 10 of 14 ROOM HEATING PEAK LOADS Project Title Date r. &Mrs. Robert Morrow-Casita Addition 11/12/2007 Room Information Design Conditions Room Name Existing Casita Time of Peak Jan 12 am Floor Area 371 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value DT of Btu/hr I 371.0 x x X X X x X x x X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 0.0720 x X x X X X X X X x X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 44 = = = = = = = = = = = = = = = = = 1,175 153.0 0.1100 44 741 171.0 0.1100 44 828 81.0 0.1100 44 392 24.0 0.7900 44 834 24.0 0.7900 44 834 24.0 0.7900 44 834 36.0 0.1100 44 174 perimeter -73.0 0,7300 44 2,345 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: I 8,1571 Infiltration: 1 1.00 X 1.064 x 371 x 9.00 X 0.502 / 60] X 44 = 1 309 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,466 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 11 of 14 ROOM HEATING PEAK LOADS Project Title Date r. & Mrs. Robert Morrow-Casita Addition 1/12/2007 oom Information Desi n Conditions Room Name Addition Time of Peak Jan 12 am Floor Area 307 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area LI -Value AT OF Btu/hr 307.0 X X X X X X X X X X X X X X X X x X X X X X X X X X X x X X X X X X X X X X X 0.0280 x X X x X X x x X X x x X X x x X X X x x X x x X X X X X X X X X X X X X X X 44 = = = = = = = = = = = = = = = = = = = = = = 378 105.0 0.0690 44 319 30.0 0.7900 44 1,043 44.0 0.0690 44 134 24.0 0.7900 44 834 95.0 0.0690 44 288 40.0 0.7900 44 1,390 194.0 0.0690 44 589 4.5 0,7900 44 156 4.5 0.7900 44 156 perimeter = 60.0 0.7300 44=1,92 Items shown with an asterisk (`) denote conduction through an interior surface to another room. Page Total: I 7,2151 Infiltration: r 1.00 X 1.064 X 307 X 9.00 X 0.502 / 6] X 44 = 1 083 schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 12 of 14 ,W RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date r. & Mrs. Robert Morrow-Casita Addition 11/12/2007 oom Information Design Conditions Room Name: Existing Casita Outdoor Dry Bulb Temperature: 11 1O Floor Area: 371 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 750F Outdoor Daily Range: 340F Opaque Surfaces Orientation ` Area U -Factor CLTD 1 Btu/hr C] Existing R-19 Roof X X X X X X X X X x xX X Existing R-11 Wall W.19.2x6.16 Existing R-11 Wall W.19.2x6.16 Existing R-11 Wall W.19.2x6.16 Existing R-11 Wall W.19.2x6.16 81.0 0.1100 31.7 NW 36.0 0.1100 29.3 24.0 64. N 371.0 X X X X X X X X X x xX X 0.0720 X X X X X X X X X X X 56.0 NE 153.0 0.1100 30.3 SE 171.0 0.1100 29.3 SW 81.0 0.1100 31.7 NW 36.0 0.1100 29.3 24.0 64. ::� Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Page Total Orientation Shaded Area X X X x X X X X X X X GLF + + + + + + + + + + + Unshaded Area X X X x X X X X X X X GLF SW 0.0 44.5 24.0 64. SW 0.0 44.5 24.0 64.1 SW 0.0 44.5 24.0 64. Page Total Internal Gain Occupants 2 X Occupants X 230 Btuh/oCC. = E ui ment 1 X Dwelling Units X 1,6001 Watts/sqft = 1,496 511 552 282 116 2 956 Btu/hr 1,538 1,538 1,538 4 615 Btu/hr 460 1,6001 Infiltration: 1.064 X 1.19 X 23.51 X = 1071 Air Sensible CFM ELA ZIT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,702 Latent Gain Occupants 0 x Occupants X 1 200 Btuh/oCC. Btu/hr 400 Infiltration: 4 771 X 1.19 X 23.51 X -0.00058 = -77 Air Latent CFM ELA QW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 323 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 13 of 14 'RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date AV. & Mrs. Robert Morrow-Casita Addition 1/12/2007 oom Information Design Conditions Room Name: Addition Outdoor Dry Bulb Temperature: 11 1O Floor Area: 307 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 75 of Outdoor Daily Range: 340F 0 opaque surraces R-38 Roof(R.30.202-16) R-21 Wall W.19.24.16 R-21 Wall .19.24.16 R-21 Wall .19.2x6.16 R-21Wall (W.19.24.16) Orientation Area X X X X X X X x x X X X U -Factor X X X X X x X X X x X X CLTD 1 = = = = = = = N 307.0 0.0280 56.0 NE 105.0 0.0690 30.3 SE 44.0 0.0690 29.3 SW 95.0 0.0690 31.7 NW 194.0 0.0690 29.3 52.8 2,111 NW 0.0 37.7 4.5 50.4 227 (NW) 0.0 37.7 4.5 50.4 227 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Page Total Btu/hr Orientation Shaded Area x x X X X X x X X X X GLF + + + + + + + + + + + Unshaded Area x X X X X X X X X X X Page GLF = = = = = - = Btu/hr (NE) 0.0 37.7 30.0 62.0 1,861 SE 0.0 37.7 24.0 46.8 1,123 SW 0.0 37.7 40.0 52.8 2,111 NW 0.0 37.7 4.5 50.4 227 (NW) 0.0 37.7 4.5 50.4 227 Total 5 549 Internal Gain Btu/hr Occu ants i 2 X Occupants X 230 Btuh/oCC. = 460 E ui ment 1 X Dwelling Units X 1,6001 Watts/sqft = 1,6001 Infiltration: 1.064 X 1.19 X 19.45 X = 886 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,885 Latent Gain Occu ants 21 X Occupants x 200 Btuh/oCC. Btu/hr 400 Infiltration: 4 771 X 1.19 X 19.45 X -0.00058 = -64 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 336 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 14 of 14