BRES2015-010278-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
BRES2015-0102
Property Address:
78735 DULCE DEL MAR
APN:
643100010
Application Description:
LUEHM BILL REMODEL
Property Zoning:
Application Valuation:
$20,000.00
Applicant:
CHARLES GARLAND
74991JOHN DR #9
PALM DESERT, CA 92260
T4'�t44Q"
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
D Q U D. Owner:
BILL L•UEHM
MAY 2 2 20150 78735, DU LCE DEL MAR
LA QUINTA, CA 92253
CITY OF LA QUINTA
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: A B D03 D06 D12 D52 C54 License No.: 3 90 -
Date: �Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractvs State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars'
($500).:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(� I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(. ) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Na
Lender's
Contractor:
DESIGNER CABINETRY & MORE
136 AVE LAS PALMAS
RANCHO MIRAGE, CA 92270
(760)641-5110
Llc. No.: 317990
Date: 5/20/2015
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by .
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation ins yrcarrier and policy number are:
Carr
r: oli
Pcy Number:_
`J certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that; if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: �� /� Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSA N COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL P ALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter.upon the above-
mentioned property for inspection purposes.
i
Da� �Zd Signature(ApplicantorAgent):
DESCRIPTION
l ••
FINANCIAL
ACCOUNT
J•
QTY
AMOUNT
PAID
PAID DATE
HOURLY PLAN CHECK - YES
101-0000-42600
2
$140.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTIf
AMOUNT
PAID
PAID DATE
HOURLY PLAN CHECK - YES
101-0000-42600
0.75
$52.50
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forBLDG CITY STAFF - PER HOUR: $192.50 $0.00
DESCRIPTION .;
ACCOUNT
CITY
AMOUNT..
PAID
PAID DATE
DEVICES, ADDITIONAL
101-0000-42403
0
$82.28
$0.00
PAID BY
METHOD .
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT :
PAID
PAID DATE
DEVICES, ADDITIONAL PC
101-0000-42600
0
$20.40
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT.
QTY
AMOUNT
PAID
PAID DATE
DEVICES,.FIRST 20
101-0000-42403
0
$24.17
$0.00
PAID BY
METHOD
RECEIPT*
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DEVICES, FIRST 20 PC
101-0000-42600
0
$24.17
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forELECTRICAL: $151.02 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
APPLIANCE REPAIR/ALTERATION
101-0000-42402
0
$12.09
$0.00
PAID. BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
APPLIANCE REPAIR/ALTERATION PC
101-0000-42600
0
$4.83
$0.00
PAID BY
METHOD ` .:
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID,.
PAID DATE
EXHAUST HOOD
101-0000-42402
0
$12.09
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
EXHAUST HOOD PC
101-0000-42600
0
$4.83
$0.00
j
77 1 - 6.
-is Vi M,
. ..... ... 11-4
Total Paid for.MECHANICAL:, $33;84 $0.00
A 0
5M
W
A'OUNTi-.'
a
ID-zDATE.r
rDESCRIPTIONt
'V g
ARM- VAI
1P
FIXTURE/TRAP
101-000042401,
0,
$12 09
'.
$0.00
B
g.,
-N
*1'-04 1 ,
'ECKBY
9 --C A!,
Tb�.
5a
0 3fil, MM -
flORM
MIN �tpmgg ig
PACCOUN mg
NEI'.
IOUNTImIT",
m t�g
'r P A I D
0AI DATE'
b'
mmmu,
31
11,!g ...
FIXTURE/TRAP PC',
0 $12.09
$0.00
g 'JiU
LiA
kc E
M
MA?ViP ge-RATI&O V1,1150"
NO
-71 W I OR We 4
Vgg". I ""I
M
RACCOUN
! , , .. 4�
N
�OV�A'IVIOUNT
L5. ? ' -
- , ATE,
0.-W V 7,1`wli�,!-�
rnmp,� Mu Z�w
2
WATER SYSTEM INST/ALT/REP.
101-0000-412401
0
$12,09
$0.00'
u.g 'g. _n
Oil- p—
m43'
''MR-R,W-0 1z
g';
RECEIPT W
tECEIP4
-HE
L
,Hb
�-g
DESCRIPTIONS-m' q
g
M
R
B'�gACCOUNMm
I R
,AID�I)Amr:
WATER'SYSTEM INST/ALT/REP PC.::
161-610,0042600
0
$12'.09
$0.00
i�
MI
METHOD -N.,
'N 0 -
41.11RECE 1 P-T4#r TH
E 'N"
:R"A'
-5,CHECK*U
Total Pa.id forkumBiNd-fEES: $418*3.6, $0.00
3-41 SC I PkT 10 N R agi
R
(1)UNTifi
=PAID E
D
",PAID°QATE;
REMODEL, EA ADDITIONAL 500 SF
101-0000-424001
_.0
$65,25
0.00.
Fri; t #
-04
g" R
'10
M NRECEIPW -M, � ,
K'
-HEC V4
't
t Wl V
. W, a -0,
'ArrA
0
N
ci 6 TE
.4
I I
W, ii -10—
"al
"WN
1
-.0'.6 TI.N., "v-
RON
EA ADDITIQNAL'500 SF PC,.*,.
101-0000-42600
0
..$52.20.,
R•
Yn w-
'PA I K N-
NVRau
0 -p -ft" i�"gg;,
vM ET W
, j CEIPTI!
?-,g1icLTD
El
F';Rw
m
m
MOUNT
Pj%; FkR MAIWl
��PAIWDATE
REMODEL FIRST.100.SF -
..,101-0000-42400
0
$4931'
$0.00
wf MO..
OWNS-;
RNNRRECEIPTIW�gNl,
T
1w,
111
301
f 0
-Vl
R-11�`90
j,
ME
vm�, m I
VIM- 4:
A, 1.410
Fn
AMOUNT.
WE
!0--Z`2� �WP 1.�PAII
PAID DATE:
,0
5
-AIYW-V+M��
REMODEL; FIRST 500 SF PC
101-000042600
0—
$134.88
$0.00
"PAID`BV�
-a
METHOD
t 9
-RECEIPVW�t
CHECK -V
N AMM -
E.
R
Total Paid for REMODEL. -64 :$0-00
V
'--INKW�W V
M
AMOUNTS -PAID
S
"6j AiEi
01.
MTN,
SMI.: RESIDENTIAL
101-00001-20308.
'0
$2.60.1
$0.00
®R R A
METHOD411
I #Fk,,
mffl)z R E C E I
ECK,,*-�,
T -
0
TIRE
- `
x PT -g mwsun
�T. q.
OF -1.�6
N
Total Paid foeSTRONG MOTION INSTRUMENTATION'SMI: ;$2.-60 $0.00
Permit Details PERMIT NUMBER
City of la Quinta BRES2015 QW
Description: LUEHM BILL REMODEL
ADDITIONAL
Type: BUILDING, RESIDENTIAL
Subtype: REMODEL
Status: APPROVED
Applied: 3/19/2015 PJU
Approved: 5/19/2015 JJO
Parcel No: 643100010 Site Address: 78735 DULCE DEL MAR LA QUINTA,CA 92253
Subdivision: TR 26152
Block:
Lot: 189
Issued:
Lot Sq Ft: 0
Building Sq Ft: 0
Zoning:
Finaled:
Valuation: $20,000.00
Occupancy Type:
Construction Type:
Expired:
No. Buildings: 0
No. Stories: 0
No. Unites: 0
Details: INTERIOR REMODEL - KITCHEN AND EXTERIOIR SOUTH WALL. 2013 CALIFORNIA BUILDING CODES.
Printed: Wednesday, May 20, 2015 2:55:32 PM 1 of 4 CR
SYS7EAAS
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES "• ""'
NON STRUC RFC
NOTE
JIM JOHNSON
3/27/2015
4/8/2015
PLANS READY FOR CORRECTIONS
NON STRUC APPROVED PENDING STRUC APPROVAL
NOTE
JIM JOHNSON
5/13/2015
5/19/2015
STRUCTURAL REVIEW IS COMPLETE
PLAN CHECK COMMENTS
FROM CONSULTANT
LUIS URIBE
5/18/2015
5/18/2015
STRUCTURAL REVIEW COMPLETE AND APPROVABLE
RECEIVED
PLAN CHECK.COMMENTS
FROM CONSULTANT
PHILIP JUAREZ
4/6/2015
4/6/2015
RECIEVED PLANS; NOT APPROVABLE PER YOUNG
RECEIVED
PLAN CHECK PICKED UP
PHILIP JUAREZ
4/9/2015
4/9/2015
PLANS PICKED UP BY RUBEN ROMERO 760-340-3528
PLAN CHECK SUBMITTAL
PHILIP JUAREZ
3/19/2015
3/19/2015
RECEIVED
Printed: Wednesday, May 20, 2015 2:55:32 PM 1 of 4 CR
SYS7EAAS
Printed: Wednesday, May 20, 2015 2:55:32 PM 2 of 4
C9MV-1YSTFti1S
FINANCIAL
INFORMATION
APPLICATION RECEIVED AT FRONT COUNTER ON 3/19/15.
SENT TO PLAN CHECK
KAY HENSEL
3/23/2015
3/23/2015
PROCESSED STRUCTURAL PORTION FOR 1ST PLAN CHECK
CONSULTANT
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
(YOUNG) ON 3/23/15
CALLED CHUCK GARLAND THAT PLANS ARE READY FOR
TELEPHONE CALL
T
JIM JOHNSON
4/8/2015
HOURLY PLAN CHECK -
4/8/2015
2
$140.00
$0.00
CORRECTIONS
CALLED CHARLES GARLAND TO INFORM HIM PLANS ARE
TELEPHONECALL
JIM JOHNSON
5/19/2015
0.75
5/19/2015
$0.00
YES
READY TO ISSUE.
CONDITIONS
Total Paid for BLDG CITY STAFF - PER HOUR: $192.50 $0.00
CONTACTS
101-0000-42403
0
$82.28
$0.00
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
CHARLES GARLAND
74991JOHN DR #9
PALM DESERT
CA
.92260
ARCHITECT
GLS ARCHITECTURE
74991 JONI DR #9
PALM DESERT
CA
DEVICES, FIRST 20
101-0000-42403
0
CONTRACTOR
DESIGNER CABINETRY & MORE
136 AVE LAS PALMAS
RANCHO
CA
92270
MIRAGE
OWNER
BILL LUEHM
78735 DULCE DEL MAR
LA QUINTA
CA
92253
Printed: Wednesday, May 20, 2015 2:55:32 PM 2 of 4
C9MV-1YSTFti1S
FINANCIAL
INFORMATION
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY .
HOURLY PLAN CHECK -
101-0000-42600
2
$140.00
$0.00
YES
HOURLY PLAN CHECK -
101-0000-42600
0.75
$52.50
$0.00
YES
Total Paid for BLDG CITY STAFF - PER HOUR: $192.50 $0.00
DEVICES, ADDITIONAL
101-0000-42403
0
$82.28
$0.00
DEVICES, ADDITIONAL
101-0000-42600
0
$20.40
$0.00
PC
DEVICES, FIRST 20
101-0000-42403
0
$24.17
$0.00
Printed: Wednesday, May 20, 2015 2:55:32 PM 2 of 4
C9MV-1YSTFti1S
DESCRIPTION
ACCOUNT.
CZTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD `
PAID BY
CLTD .
BY.
DEVICES, FIRST 20 PC
101-0000-42600
0
$24.17
$0.00
Total Paid forELECTRICAL: $151.02 $0.00
APPLIANCE
101-0000-42402
0
$12.09
$0.00
REPAIR/ALTERATION
APPLIANCE
101-0000-42600
0
$4.83
$0.00
REPAIR/ALTERATION PC
EXHAUST HOOD
101-0000-42402
0
$12.09
$0.00
EXHAUST HOOD PC
101-0000-42600
0.
$4.83
$0.00
Total Paid forMECHANICAL: .$33.84 $0.00
FIXTURE/TRAP
101-0000-42401
0
$12.09
$0.00
FIXTURE/TRAP PC
101-0000-42600
0
$12.09
$0.00
WATER SYSTEM
101-0000-42401
0
$12.09
$0.00
INST/ALT/REP
WATER SYSTEM
101-0000-42600
0
$12.09
$0.00
INST/ALT/REP PC
Total Paid for PLUMBING FEES: $48.36 $0.00
REMODEL, EA
101-0000-42400
0
$65.25
$0.00
ADDITIONAL 500 SF
REMODEL, EA
101-0000-42600
0
$52.20
$0.00
ADDITIONAL 500 SF PC
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$0.00
REMODEL, FIRST 500 SF
101-0000-42600
0
$134.88
$0.00
PC
Total Paid forREMODEL: $301.64 $0.00
SMI - RESIDENTIAL
101-0000-20308
0
$2.60
$0.00
Total Paid forSTRONG MOTION INSTRUMENTATION SMI $2.60 $0.00
Printed: Wednesday, May 20, 2015 2:55:32 PM 3 of 4 CR
sys7eMs
TOTALS: $729.96 $0.00
r
PARENT PROJECTS
INSPECTIONS
SEQID INSPECTION TYPE . INSPECTOR SCHEDULED COMPLETED
DATE DATE
RESULT REMARKS NOTES
FINAL" BLD
PARENT PROJECTS
Printed: Wednesday, May 20, 2015 2:55:32 PM 4 of 4 CR
sysreiYts
ATTACHMENTS
RETURNED
REVIEWS
STATUS
REMARKS
,,,,,. ,.
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
4/8/2015
JIM JOHNSON
78-735 DULCE DEL
MAR.docx.
NOTES
0
DOC
5/18/2015
DATE
2ND REVIEW
STRUCTURAL
TRANSMITTAL
BRES2015-0102 - 2ND
REVIEW STRUCTURAL
TRANSMITTAL.pdf
NON-STRUCTURAL
JIM JOHNSON
3/23/2015
4/2/2015
3/27/2015
REVISIONS REQUIRED
1
PLANS RECEIVED ON 19TH BUT NOT PROCESSED
STRUCTURAL
YOUNG
3/23/2015
4/2/2015
4/6/2015
REVISIONS REQUIRED
OR SENT UNTIL THE 23RD
ENGINEERING
PLANS NOT APPROVABLE PER YOUNG.
NON-STRUCTURAL
JIM JOHNSON
4/30/2015
5/14/2015
5/13/2015
APPROVED
APPROVED PENDING STRUC APPROVAL
YOUNG
4/30/2015
'5/14/2015
5/15/2015
READY FOR APPROVAL
STRUCTURAL
ENGINEERING
Printed: Wednesday, May 20, 2015 2:55:32 PM 4 of 4 CR
sysreiYts
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
4/8/2015
JIM JOHNSON
78-735 DULCE DEL
MAR.docx.
78-735 DULCE DEL
MAR.docx
0
DOC
5/18/2015
LUIS URIBE
2ND REVIEW
STRUCTURAL
TRANSMITTAL
BRES2015-0102 - 2ND
REVIEW STRUCTURAL
TRANSMITTAL.pdf
0
DOC
4/7/2015
PHILIP JUAREZ
1703_001.pdf
1703_001.pdf
1
Printed: Wednesday, May 20, 2015 2:55:32 PM 4 of 4 CR
sysreiYts
�19
r
Bin #
tIN City of La Quin t*
S Building &r Safety Division
P.O. Box 1504, 78-495 Calle Tampico .
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address: Al 3Owner's
Name: y EA
A. P. Number: 1913 _ A00— 0/0 —7
Address: _
Legal Description:Iff-VYAARal,1
City, ST, Zip: 1A Q=J6
Telephone: :::; ,.::. >>;; ;>:.:.:::;.•:;;.,<;,:,•
Contractor:
� O
Address: IASProject
MA 1 -
Description:
City, ST, Zip:
Te eP h ne• 0
1 0
y S O'
r
State Lic. # : q D
City Lie. #:
_
Arch., Engr., Designer:
C7V/Z
Address: _
City., ST, Zip: ?A
eA D
Telephone: _
Construction Type: Occupancy:
�1M /�D /
€AdC/A{
State Lic. #:9.7
zz
Project type (circle one): New Add'n Alte Repair
Demo
Name of Contact Person: 49 FS
b 6ARIA14D , .
Sq. Ft.: o; 71
#.Stories:
#Units:
Telephone #,of Contact Person:
Estimated Value of Project: O opo, e
APPLICANT: DO NOT WRITE BELOW THIS LINE
# Submittal Req'd Recd TRACKING PERMIT FEES
Plan Sets
a
Plan Check submitte
3
Item
Amount
Structural Calcs.
p�
Reviewed, readfor corrections
4
Plan Check Deposit
Truss Cates.
Called Contact Pe
Plan Check Balance.
Title 24 Calcs.
d
Plans picked up,
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2" Review, ready for correctionsissue
S I
Electrical
Subeontactor List
Called Contact Person
Plumbing
Grant Decd
Plans picked up
S.M.I.
Ii.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'`" Review, ready for eorrectionsCssue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
u��' Ply 12�FG
S (� MS fWPRau6-9
CITY. OF LA QUINTA .SUR -CONTRACTOR_ LISTtq L(�
JOB ADDRESS 79773T IXU CC 17�1- 1W,eL m PERMIT. NUMBERj3XCS,Ue5W0Z0OWNER
This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work
on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance.
of building permit. For each applicable trade, all information requested below must be compieted by applicant. "On File" is not an acceptable response.
Company Name
Classification
(e.g. A, B, C-8)
License Number
(xxxxxx)
Exp. Date
(xx/xxlxx)
Carrier Name
(e.g. State Fund, CalComp)
Policy Number
(Format Varies)
Exp. Date
(xx/xx/xx)
License Number
(xxxx)
Exp. Date
(xx/xx/xx)
ty
�l
1
-!' t.L
><i' -�
i�3 6r 6
1YIT F'
hlt - f�3G
I cam'
—/9)
?Cb'"�l10
3 3't /
11fd� �i.Rhst/c
Gsas8ls 3�.
rGase
/S
s
OFF I( Er /ri,
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
LUEHM RESIDENCE's alteration
78735 DULCE DEL MAR
LA QUINTA, CA 92253
Project Designer:
GLS ARCHITECTURE GROUP INC.
74991 JONI DR #9
PALM DESERT, CA 92260
760 340.3528
Report Prepared by:
Armando Chavez
TITLE 24 OF THE DESERT SERVICES INC.
74800 SHERYL AVE #62
PALM DESERT, CA 92260
760 278.1840
CITY OF LA QUINTA ��IMTZ
BUILDING & SAFETY DEPT. "dM
. APPRVED
FOR CONST UCTION
Job Number:
15 -GLS -012-1 R
Date:
4/28/2015
APR 3.0 2015
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
1 EnermyPro6.4bvEneroVSoft User Number: 20648 ID:201SGLS-072-1H U1
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF -1 R -PRF -01-E Certificate of Compliance
Form RMS -1 Residential Measures Summary
Form MF -1 R Mandatory Measures Summary
V
EnergyPro 6.4 by EnergySoft Job Number: ID: 2015 -GLS -012-1 R User Number: 20648
1
2
3
11
12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: LUEHM RES ADD. Calculation Date/Time: 10:24, Tue, Apr 28, 2015
Calculation Description: Title 24 Analysis
Input File Name: 1 R-012-LUEHM RES.xml
CF1 R -PRF -01
Page 1 of 8'
GENERAL INFORMATION
01
Project Name LUEHM RES ADD.
02
Calculation Description Title 24 Analysis
03
Project Location 78735 DULCE DEL MAR
04
City LA QUINTA
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-3b1 (694)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.4
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 0
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (FT2) 2738
15
Number of Zones 1
16
Slab Area (FT2) 2738
17
Number of Stories 1
18
Addition Cond. Floor Area 0
19
Natural Gas Available Yes
20
Addition Slab Area (FT2) 0
21
Glazing Percentage (%) 19.2%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
03 This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04 05
06
07
08
Energy Use Standard
(kTDV/ft2-yr) Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating 1.66
0.96
0.70
42.2%
Space Cooling 293.48
292.49
0.99
0.3%
IAO Ventilation 0.00
0.00
0.00
0.0%
Water Heating 9.79
9.79
0.00
0.0%
Photovoltaic Offset ----
0.00
0.00
----
Compliance Energy Total 304.93
303.24
1.69
0.6%
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694
HERS Provider:
Report Generated at: 2015-04-2810:30:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: LUEHM RES ADD. Calculation Datefrime: 10:24, Tue, Apr 28, 2015
Calculation Description: Title 24 Analysis Input File Name: 1 R-012-LUEHM RES.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Exposed slab floor in conditioned zone
CF1 R -PRF -01
Page 2 of 8
HERS FEATURE SUMMARY
The following is a -summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• — None --
Cooling System Verifications:
• -- None -
HVAC Distribution System Verifications:
• — None --
Domestic Hot Water System Verifications:
• --None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)* 347.78 346.09 1.69 0.5%
" includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
LUEHM RES ADD.
2738
1
2
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)Height
Avg. Ceiling
Water Heating System 1
Water Heating System 2
EXISTING
Conditioned
HVAC1
2738
10
DHW Sys 1
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-04-2810:30:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: LUEHM RES ADD. Calculation Datefrime: 10:24, Tue, Apr 28, 2015
Calculation Description: Title 24 Analysis
Input File Name: 1 R-012-LUEHM RES.xml
CF1 R -PRF -01
Page 3 of 8
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window and Door
Area (ft2)
Tilt
(deg)
Status
Verified
Existing
Condition
N-541
EXISTING
Default Wall 1992 to Pres
0
Front
541
24
90
Existing
No
E-820
EXISTING
Default Wall 1992 to Pres
90
Left
1012
42.7
90
Existing
No
S-657
EXISTING
Default Wall 1992 to Pres
180
Back
657
360
90
Existing
No
W-820
EXISTING
Default Wall 1992 to Pres
270
Right
820
100
90
Existing
No
2738
EXISTING
Default Roof 1978 to Pres
2738
Existing
No
ATTIC
01
02
03
04
05
06
07
08
09
Name
Construction
Roof Rise
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool Roof
Status
Verified
Existing
Condition
Attic EXISTING
Attic Roof Cons EXISTING
4
0.1
0.85
No
No
Existing
No
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694
HERS Provider:
Report Generated at: 2015-04-2810:30:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: LUEHM RES ADD. Calculation Date/Time: 10:24, Tue, Apr 28, 2015
Calculation Description: Title 24 Analysis
Input File Name: 1 R-012-LUEHM RES.xml
CF1 R -PRF -01
Page 4 of 8
WINDOWS
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Height (ft)
Multiplie
r
Area (ft)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
1680
N-541 (Front -0)
----
----
1
12.0
0.55
0.55
Insect Screen (default)
Existing
No
16802
N-541 (Front -0)
1
12.0
0.55
0.55
Insect Screen (default)
Existing
No
16803
E-820 (Left -90)
----
----
1
12.0
0.55
0.55
Insect Screen (default)
Existing
No
6810
E-820 (Left -90)
----
1
6.7
0.55
0.55
Insect Screen (default)
Existing
No
3080
E-820 (Left -90)
----
----
1
24.0
0.55
0.55
Insect Screen (default)
Existing
No
10080
S-657 (Back -180)
----
----
1
80.0
0.55
0.55
Insect Screen (default)
Existing
No
14080-N
S-657 (Back -180)
----
1
112.0
0.49
0.33
Insect Screen (default)
New
N/A
8080-N
S-657 (Back -180)
----
----
1
64.0
0.49
0.33
Insect Screen (default)
New
N/A
6080-N
S-657 (Back -180)
----
----
1
48.0
0.49
0.33
Insect Screen (default)
New
N/A
7080
S-657 (Back -180)
----
----
1
56.0
0.55
0.55
Insect Screen (default)
Existing
No
3068
W-820 (Right -270)
----
----
1
20.0
0.55
0.55
Insect Screen (default)
Existing
No
2680
W-820 (Right -270)
----
----
1
16.0
0.55
0.55
Insect Screen (default)
Existing
No .
8080
W-820 (Right -270)
----
----
1
64.0
0.55
0.55
Insect Screen (default)
Existing
No
DOORS
01 02 03 04 05 06
Name Side of Building Area (ft) U -factor Status Verified Existing Condition
5080 E-820 40.0 1.00 Existing No
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694
HERS Provider:
Report Generated at:,2015-04-28 10:30:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: LUEHM RES ADD. Calculation DatelTime: 10:24, Tue, Apr 28, 2015
Calculation Description: Title 24 Analysis
Input File Name: 1 R-012-LUEHM RES.xml
CF1 R -PRF -01
Page 5 of 8
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
09
Name
Zone
Total Cavity
Winter Design
Edge Insul. R -value
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
0.1
None
0
No
Existing
No
- Cavity/ Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
- Roof Deck: Wood Siding/sheathing/decking
Attic Roof Cons EXISTING
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
- Roofing: Light Roof (Asphalt Shingle)
- Inside Finish: Gypsum Board
Ceilings (below
• Cavity/ Frame: R-9.1 /2x4
Default Roof 1978 to Pres
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 21
0.045
- Over Floor Joists: R-11.9 insul.
- Inside Finish: Gypsum Board
• Cavity/Frame: R -13/2x4
- Exterior Finish: Wood
Default Wall 1992 to Pres
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft2)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
27382
EXISTING
2738
0.1
None
0
No
Existing
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (011) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Not Required Not Required Not Required ---
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
M
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
Annual
Existing
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R701152015-694 Report Generated at: 2015-04-28 10:30:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: LUEHM RES ADD. Calculation Date/Time: 10:24, Tue, Apr 28, 2015
Calculation Description: Title 24 Analysis
Input File Name: 1R-012-LUEHM RES.xml
CF1 R -PRF -01
Page 6 of 8
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.58 EF
40000-Btu/hr
0
0.04
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
01
02
03
04
05
06
07
08
09
Name
Heating System
Cooling System
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
7.06
8
No
No
Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
HVAC1
Other Heating and
Heating
Yes
Cooling
Yes
Air Distribution
HVAC Fan
2738
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 78 AFUE
HVAC- COOLING SYSTEMS
01
02
03 04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
7.06
8
No
No
N/A
system
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-01152015-694
HERS Provider:
Report Generated at: 2015-04-28 10:30:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: LUEHM RES ADD. Calculation Date/Time: 10:24, Tue, Apr 28, 2015
Calculation Description: Title 24 Analysis
Input File Name: 1 R-012-LUEHM RES.xml
CFI R -PRF -01
Page 7 of 8
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
4.2
Attic
Attic
None
Existing
No
N/A
System 1
specified)
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R=01152015=694 Report Generated at: 2015-04-2810:30:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: LUEHM RES ADD. Calculation Date/Time: 10:24, Tue, Apr 28, 2015
Calculation Description: Title 24 Analysis
Input File Name: 1 R-012-LUEHM RES.xml
CF1 R -PRF -01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Documentation Author Signature:
Armando Chavez
Company:
Signature Date:
TITLE 24 OF THE DESERT SERVICES INC.
4/28/2015
Address:
CEA/HERS Certification Identification (If applicable):
74800 SHERYL AVE #62
City/StatePALM DESERT, CA 92260
Phone: 760 278.1840
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
RUBEN ROMERO
Company:
Date Signed:
GLS ARCHITECTURE GROUP INC.
Address:
License:
74991 JONI DR #9
City/State/Zip:
Phone:
PALM DESERT, CA 92260
760 340.3528
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-04-2810:30:30
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
LUEHM RESIDENCE'S alteration
Building Type m Single Family ❑ Addition Alone
. ❑ Multi Family m Existing+ Addition/Alteration 1412812015
Date
Project Address
78735 DULCE DEL MAR LA QUINTA
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,738
Addition
0
# of Units
1
INSULATION
Construction Type
Area
Cavi (ft) Special Features Status
Slab Unheated Slab -on -Grade - no insulation 2,738 Perim = 0' Existing
Roof Wood Framed Attic R 21 2,738 Existing
Wall Wood Framed R 13 2,463 Existing
Door Opaque Door -
no insulation 40 Existing
FENESTRATION I Total Area: 527 Glazing Percentage: 19.2%1New/Altered Average U -Factor: 0.49
Orientation Area(ft2) U -Fac SHGC Overhang Sidefins Exterior Shades Status
Front (N) 24.0 0.550
0.55 none none Bug Screen Existing
Left (E) 42.7 0.550
0.55 none none Bug Screen Existing
Rear (S) 136.0 0.550
0.55 none none Bug Screen Existing
Rear (S) 224.0 0.490
0.33 none none Bug Screen New
Right (Vtq 100.0 0.550
0.55 none none Bug Screen Existing
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 78% AFUE
Split Air Conditioner 8.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC Ducted
Ducted Attic 4.2
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnergyPro 6.4 by Ener Soft User Number: 20648
RunCode: 201 5-04-28 71 0:30:58 /D: 2015 -GLS -012-1R
Pae 11 of 15
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§ 110.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§I 10.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 1 10.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110 8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 1 10.8(1) when the
installation of a cool roof is specified on the CFI R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1 R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ I50.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§I50.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§I50.0(d):
Minimum R-19 insulation in raised wood -frame floor o� 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class 11 vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§I50.0(g)1:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class 11
§I50.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class It vapor retarder shall be placed over the earth floor of
§I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8( ).
§ 150.0 (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§I50.0(e)I A:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§I50.0(e)I B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§ 150.0(e)1 C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
§150.0(e)2:
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§I 10.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
§150.0(h)1:
in §150.0(h)2.
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
§ 150.0(h)3A:
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§ 150.0(j)1 A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
§150.00)1 B:
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
§ 150.00)2B:
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§150.00)2C:
Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§I50.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3 B:
or Class 11 vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class 11 vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ I50.0(n)l :
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§I50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ I50.0(m)l :
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than %< inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ 150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§I50.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§I50.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§I50.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§I50.0(m)13:
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ I50.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of AS14RAE Standard 62.2. Neither window operation nor continuous operation of
§ I50.0(o):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§ I50.0(o)I A:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§I 10.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 1 10.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§1 10.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ I50.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§1 10.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9.
§I50.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§I50.0(k)I B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ I50.0(k)I C:
§ I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§I50.0(k)I Q:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§I50.0(k)I E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §I30.0(c). Night lights do not need to
be controlled by vacancy sensors.
§ 150.0(k) I F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§I50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ I50.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§I50.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k).
§I50.0(k)2F:
Lighting controls comply with applicable requirements of §110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in ' 150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of §150.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § I50.0(k)2.
§I50.0(k)21:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to §110.9, and complies with all other applicable requirements in §I50.0(k)2.
§ I50.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§I50.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§I50.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§I50.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§I50.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy; or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§I50.0(k)9B:
following requirements:
i. Shall comply with § I50.0(k)9A; or
ii. Shall comply with the applicable requirements in §110.9, § 130.0, §130.2, §130.4, §140.7 and §141.0.
§I50.0(k)9C:'
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §I50.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in §110.9, §130.0, §130.2, §130.4, § 140.7 and §141.0.
§I50.0(k)10:
Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§I50.0(k)1 l:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
' '
nonresidential garages in § 110.9, § 130.0, § 130. 1, 130.4, § 140.6, and 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k) I2A:
the Floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)l2B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§1 10.10(a) l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of §1 10.10(b) through §1 10.10(e).
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 1 10.10(b) through § 1 10.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§110.10(b)l:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§1 10,10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 1 I O, I0(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110,10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 1 10.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§1 10.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and ennanently marked as "For Future Solar Electric".