Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13143 (SFD)
4 P.O. BOX 1504 N o . 13143 Building 78-105 CALLE ESTADO Address 77-205 Durango LA QUINTA, CALIFORNIA 92253 Owner - David MOSS Millar Mailing BUILDING: TYPE CONST. OCC: GRP. Address P.O. Box 722 773-201-006 A.P. Number City Zip Tel. Lot Block 3 La Quinta, CA X52253 Legal Description Contractor Project Description AFD .Pacific Trades Address Syne City Zip Tela State Lic. City & Classif. 3 3425381 Lic. # 1955 Sq. Ft. No. No. Dw. Size 12.57 Stories Units Arch., Engr., _Designer New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ ' 'Address Tel. Permit does not include block wall Or Pool. ' City Zip State Lic. # LICENSED CONTRACTOR'S DECLARATION I here affirrq hat am licensed un er provisipppQs of Chapter g (commencing with Section 000) of lvision of Business an ofessiofrs Code, and my license Is in full force and ' feffe RRRN " A I u DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Buslness and Professions Code: Any city or county which requires a - Permit to construct, atter, improve, demolish, or repair. any structure, prior to its issuance also requires the -applicant for such permit to 81e a signed statement that he is licensed pursuant to the 'Provisions of the Contractor's license Law, Chapter 9 (commencing with Section 7000) or Division 3 of the Business and Professions Code, or that, he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjectsthe applicant to a civil penally of not more than five hundred dollars ($500). O I,:as:owoer of the property, or my employees with wages as their sole compensation, will d ,1.ho work; and the structure is not Intended or offered for sale. (Sec. 7044, Buisness and Prolessloils. Code:. The Contractor's License Law does not apply to an owner of property who builds or Improves thereon and who does such work himself or through his own employees,0 proddedrthat_:such improvements are not intended or offered for sale. If, however, the building Estimated Valuation �'� e 8 5.50 $76,815.50 . PERMIT AMOUNT Plan Chk. Dep. Plan Chk. BBI. c7r� . 2 Const. r 545 e McQh. a ., Electrical 117.58 or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not, build or Improve for the purpose of sale.) 0 I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for .suchpiof is with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Plumbing 'v 141.00 - .S.M.I. _ 7. 70 - _ Grading 1 ; hQ • 00 Driveway Enc. r 000 Date owner Infrastructure 1 , ro 0 . 0 Precise Plan f25.00 WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or. a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, labor Code.) Policy -v Company opy is filed with the city. 0 Certified copy is hereby furnished. TOTAL i • 0 CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE REMARKS (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ anyparson in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: ff, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permitshallbe deemed revoked. ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line CONSTRUCTION LENDING AGENCY I=affirm that there is a construction lending agency for the performance of the work for which this permit is Issued. (Sec. 3097, Civil Code.) Side Street Setback from Center Line Side Setback from Property Line Lender's Name Lender's Address This Is a building permit when properly filled out, signed and validated, and is subject to expiration If work thereunder, is suspended for 180 days. FINAL DATE INSPECTOR I certify that I have read this application and state that the above Information Is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-. mentioned property for inspection purposes. ISSuediiby- Date Permit Validated by: Signature of applicant Date Mailing Address Validation: City, State, Zip CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEE?, 1ST FL. SO. FT. ® $ UNITS r' BONDING HEATING (ROUGH) YARD SPKLR SYSTEM 2N0 FL, SO. FT. SEWER OR'S1TTI�FRNIf 7� OUGH WIRING DUCT WORK MOBILEHOME SVC. BAR SINK POR. SO. FT. ® METER LOOP HEATING (FINAL) GAR. SO. FT. ® POWER OUTLET ROOF DRAINS TEMP. POLE ee DRAINAGE PIPING CAR P. I SO. FT. ® WATER HEATER SERVICE WALL SO. FT. @ DRINKING FOUNTAIN WATER SYSTEM URINAL SO FT ® LUMBER GR. FINAL INSP. ESTIMATED CONSTRUCTION VALUATION $ -- - - ---• - — - • - WATER PIPING NOTE: Not to be used as property tax valuation FLOOR DRAIN MECHANICAL FEES WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRY TRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE, TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. @ c BATH TUB SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 1 Va c SEWAGE DISPOSAL SO.FT.GAR @ 3/ic HOUSE SEWER FINAL INSPECTIONO? -jD�9 cc GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE / PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR ■ SETBACK GROUND PLUMBING NDERGROUND A.C. UNIT COLL. AREA SLAB GRADE g ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS �� SEWER OR'S1TTI�FRNIf 7� OUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE ee GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING —cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP. FRAMING FINAL INSP 8 ROOFING of VENTILATION ' •7 llo Frew rqr REMARKS: FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATION/SOUND FINISH GRADING FINAL INSPECTIONO? -jD�9 cc CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE:. Indio, CA 92201 Document Cannot Be Duplicated (619) 347-8631 Date 112/28/921 Type of 2.'(4%'a No. 111922 " I Owner Name Roger Snellenberger og No. 77205 Street Durango City La Quinta Zip 92253 Study Area 113 AEN # 773-201-006-6 1 Tract # I j Lot # © Square Footage 11347 Type ofDevelopment Single Family Residence No. of units 0 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/ carports, covered patios/ walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.58 x 1 47 or $ 2,128.26 have been paid to D.S.U.S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Roger Snellenberger Telephone Name on the check By Tamps F. Eively Assistant Superintendent, Business Services Fee collected /exempted by Vickie. J. Durrett _ Payment Received SignatureCheck No. 001911 Collector. Attach a copy of. county or city plan check application form to district: copy for all waivers. Embossed Original Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting C�Yt�r of 14EU Ouinta Iluffbing,anb -Sttfet� _13rtisinn This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building! Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: t BUILDING ADDRESS 77"205 Calle Durango Use classification Single Family Dwelling Bldg. Permit No. 13143 Group R3 Type Construction Vn Fire Zone use Zone. SR' Owner of,Building David Ross Miller Address P.O. Box 722 City La Quinta, CA 922.53 Lonnie Day By: r per. September 9, 1993 Building Officiel POST IN A OONB}ICUOUB PLACt y =Jill ENERGY CONSULTING GROUP 1 Indian Hills Dox. 34F l�J= Mountain Center, CA 92361 Lic 473969 January 7, 1992 DAVE MILLER PACIFIC TRADES LA QUINTA, CA INVOICE 1 Set Residential Title 24 Compliance Reports $100.00 Than you, W. J. Finnell Residential & Commercial Energy Consultants 1-800-262-9966 ak ENERGY CONSULTING GROUP Indian Hills Dox 34F IIS Mountain Center, CA 92361 Lic 473969 The following are some explanatory notes concerning the enclosed forms: C2R The compliance margin is a positive number --the building, as described in these reports, complies with the Califor°nia Energy Commission requirements. CF -1R Page 2 should'be signed by the building designer and owner. Please note any remarks that may appear in the "Special Features/Remarks" section. These components are required standards for your build- ima . Also, the brand name and model number of the furnace, air conditioning and, hot water systems you plan to install should be -entered. MF -1R Lists the mandatory items required by the California Energy Commission. This form needs to be completed by the builder or owner. HVAC SIZING calculations are used to indicate the basic heating and air conditioning requirements ( Btu) for Your particular building. Please note that this is a guideline and the person selecting this equipment needs to consider all factors involved (such as air flow restrictions, safety margins, etc_.) when making these choices. Please contact us if you have any questions concerning this compliance package. Thank you, W. J. Finnell Enclosures Residential & Commercial Energy Consultants 1-800-262-9966 COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... PACIFIC Date.. -....^01/07/92 Project Address........ LA :DUINTA --------------------- Documentation Author... W J FINNELL ; Building Permit # Company ................ ENERGY CONSULTING GROUP Telephone............... 1-800-262-99.66 ; Plan Check / Date ; Compliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date Climate Zone........... 15 ---------------------i MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM C -2R ; User#-MP132S User -ENERGY CONSULTING GROUP Run -PACIFIC MICROPAS3 ENERGY USE SUMMARY = _---------------------------- Proposed Compliance _ Design = Energy Use Standard. _ (, kBtu/sf-yr ) Design = Space Heating...... .. 6.73 = Space Cooling.......... 48.63 = Water Heating. ....... 14.88 = Total 70.24 Proposed Compliance _ Design Margin = 3.86 2.87 = 41.08 7.55 = 21.97 -7.09 = 66.91 3.33 = ***Building complies with Computer Performance ** - GENERAL INFORMATION ------------------- Conditioned Floor Area ..... 1257 sf Building Type.............. Single Family Detached Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type......:... ReducedYear Floor Construction Type.... Number of Building Zones... Conditioned Volume.......,. Footprint Area ............. Slab -On -Grade Area. ....... Glazing Percentage. ...... Average Ceiling Height..... Slab On Grade ( Package D) 1 10936 cf 1257 sf 1257 sf 10.8 % of FA 8.7 ft BUILDING ZONE INFORMATION ------------------------- Floor # of Vent Special Cond- Area Volume Dwell Thermostat Height Vent Area Zone Type itioned (sf ) ( cf ) Units Type (ft) (sf) HOUSE Residence Yes 1257 10936 1.00 Setback 2.0 n/a COMPUTER METHOD SUMMARY___ Area # of Frame Open Page 2 C -2R Project Title.. PACIFIC________________________________________________ (sf) Panes Type ------------ .. _-- Date......... 01/07/92 Tilt Only MICROPAS3 x3.1.1 File -PACIFIC Wth-CTZ15 Program -FORM C -2R ' ----------------------------------------------------------------------------- User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC I ---- ----- ---------- OPAQUE SURFACES 1 Window 2 Window Surface Area (sf) --------------- U- Insul Act value R--val.Azmth Solar Location/ Tilt Gains Comments Form 3 drapes 0.66 ----- ----- ----- 16.0 49.0 Reference HOUSE 0.65 180 90 0.77 ---- --------------------- ------------- 1 Wall 2 Wall 110 0.06b R-19 90 90 Yes OUTSIDE None 3 Wall 160 0.065 R-19 90 '90 No GARAGE None 4 Wall 268 0.065 R-19 180 90 Yes OUTSIDE None 5 Wall 247 0.065 R-1.9 270 90 Yes OUTSIDE None 6 Roof 249 0.065 R-19 0 90 Yes OUTSIDE None 7 Door 1257 0.029 R-38 0 0 Yes ATTIC None 20 0.330 R-0 90 90 Yes FWALL None PERIMETER LOSSES ---------------- HOUSE ---------- Length F2 Insul Surface ------------ (ft) Factor -------------- R-val Location/Comments bug scrn 0.84 HOUSE ------- ----------------------- 2 Window 8 S1abEdge 9 0.900 R-0 OUTSIDE 9 S1abEdge 116 0.720 R-0 OUTSIDE ` 49.0 50% bug scrn 1.0 S1abEdge 20 0.500 R-0 GARAGE GLAZING SURFACES Area # of Frame Open U- Act SC Glass Interior Shade SC Gls+ Surface (sf) Panes Type ------------ Type ------ value Azmth Tilt Only Type Shade HOUSE- ----- ----- ---- ----- ---------- ----- 1 Window 2 Window 26.0 2 (Metal Slider 0.65 90 90 0.77 drapes 0.66 3 Window 16.0 49.0 2 Metal. Slider 0.65 180 90 0.77 drapes 0.66 4 Window 45.0 2 Metal 2 Metal Slider Slider 0.65 270 90 0.77 drapes 0.66 0.65 0 90 0.77 drapes 0.66 EXTERIOR ---------------- SHADING Area Shading SC of Surface (sf ) Type Ext Shade HOUSE ---------- --------- 1 Window 26.0 50% bug scrn 0.84 2 Window 16.0 50% bug scrn 0.84 3 Window 49.0 50% bug scrn 0.84 4 Window 45.0 50% bug scrn 0.84 COMPUTER METHOD SUMMARY Page 3 -2R Project Title........,.. PACIFIC Date........ 01/0.7/92 MTCROPAS3 v3..11 File -PACIFIC Wth-CTZ15 Program -FORM C -2R User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC ------------------------------------------------------------------------------- THERMAL MASS HVAC SYSTEMS Area Thick Heat Conduct- Surface Efficiency ------------ Mass Type (sf) (in) Cap ivity R -value Location/Comments HOUSE HeatPump 8.0 HSPF Attic R-5 0.828 AirCond 1 S1abOnGrade 210 3.5 28.0 0.98 R-0.0 KIT/DINE/BATHS 2 S1abOnGrade 1047 3.5 28.0 0.98 R-2.0 REST OF HOUSE 3 InteriorHorz 54 1.0 24.0 0.67 R-0.0 KITCHEN/BATHS 4 InteriorVsrt 72 4.0 21.0 0.59 R-0.0 LIVING HVAC SYSTEMS Minimum, Duct Duct Duct System Type ---------------- Efficiency ------------ Location R -value Efficiency HOUSE ( Btuh ) Credits ------------- ------- ---------- HeatPump 8.0 HSPF Attic R-5 0.828 AirCond 1.0'.00 SEER Attic R-5 0.818 WATER HEATING --------------------- SYSTEMS Capa- R-12 or Pilot System # of city Greater Effic- Standby Input Size Type Heat ( gal) Blanket' iency Loss Rating ( Btuh ) Credits Storage Electric 1 37.0 No 0.99 RE .82% 4.5 kW n/ Recovery SPECIAL FEATURES/REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project.Title.......... PACIFIC Date........ 01/67/92 Project Address., ... LA QUINTA --------------------- Documentatio)n:Author... W J FINNELL. ; Building Permit # ; Company ................ ENERGY CONSULTING GROUP Telephone .............: 1-800-262-9966 ; Plan Check / Date ; Compliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date ; Climate Zone........... 1.5 --------------------- MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM CF -1R User#-MP1325 User -ENERGY CONSULTING GROUP Run-PACIFIC------------------------------------------------------------------------------- ; GENERAL INFORMATION Conditioned Floor Area..... 1257 sf Building Type... ... Single Family Detached Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade (Package D) Infiltration Control....... Standard BUILDING SHELL INSULATION ------- ------------------ Component Insul Type R -value Location/Comments Wall R-19 OUTSIDE., GARAGE Roof R-38 ATTIC Doom R-0 FWALL S1abEdge R-0 OUTSIDE, GARAGE Glazing 3.5 1047 Orientation 54 1.0 ------------------- Window Front ( E ) Window Left ( S ) Window. Back ( W ) Window Right ( N ) Type S1abOnGrade S1abOnGrade InteriorHorz InteriorVert Area # of (sf ) Panes ----- 26.0 2 16.0 2 49.0 2 45.0 2 ,Area Thickness (3f) �( i n ) 210 3.5 1047 3.5 54 1.0 72 4.0 GLAZING Interior Shading drapes drapes drapes drapes Exterior Shading Overhang 50% bug scrn None 50% bug scrn None 50% bug scrn None 50% bug scrn None THERMAL MASS ------------ Hard Surfaced/ Exposed -------------- Yes No Yes Yes Location/Comments KIT/DINE/BATHS REST OF HOUSE KITCHEN/BATHS LIVING Framing Type Metal Metal Metal Metal CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... PACIFIC Date........ 01/07/92 MICROPAS3 v3..11 File -PACIFIC Wth-CTZ15 Program -FORM CF -1R User#-MP1325 User -ENERGY CONSULTING GROUP Run-PACIFIC ------------------------------------------------------------- ----------------- ASS.UMED HVAC SYSTEMS Assumed Duct Duct Assumed System Efficiency --------------------------- Location ------------- R-value ------- HeatPump 8.0 HSPF Attic R-5 AirCond 10.00 SEER Attic R-5 ACTUAL HVAC SYSTEMS Actual Output Manufacturer and Model # Actual System ,Efficiency (Btuh) (or approved equal) --------------- ----------- -------- --------------------------------- Heating Cooling Cooling Coil CEC Maximum output for Gas Central Furnaces WATER HEATING SYSTEMS --------------------- Tank R-12 or # of Vol Greater Manufacturer and Model # System Type Heat (gal) Blanket (or approved equal) Storage, Electric 1 37.0 No WATERMISER 40FESL SPECIAL FEATURES/REMARKS Btuh Energy Credits Recovery CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... PACIFIC Date........ 01/07/92 MICROPAS3 v3.11 File -PACIFIC Wth-CTZ:15 Program -FORM CF -1R User#-MP1325 User=ENERGY CONSULTING GROUP Run -PACIFIC COMPLIANCE STATEMENT ------- ------------ This certificate of compliance lists the 'building features and performance specifications needed to comply with Title 24, Chapter 2-53 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Administrative code. This certificate has been signed by the individual with overall design responsibility and the building owner, who shall retain a. copy of it and transmit the certificate to any subsequent purchaser of the building. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, all building conservation features which vary are indicated in the Special Features/Remarks section. DESIGNER Name.... Company. Address. Phone... License. Signed (date) DOCUMENTATION AUTHOR Name.... W J FINNELL Company. ENERGY CONSULTING GROUP Address. 34F INDIIAN HILLS MTN CENTER, CA 92361 Phone..,. 1/-88010-262-9966 Name.... Company. Address. Phone.: Signed OWNER Name..... Title... Agency.. Phone... ENFORCEMENT AG Signed /� 7" Signed (date) (date) WATER HEATING Page 1 DHW ------------ Project Title.......... PACIFIC Date...... 01./07/92 Project Address.. ... LA QUINTA --------------------- Documentation Author... W J FINNELL ; Building Permit # Company ................ ENERGY CONSULTING GROUP Telephone .............. 1-800-262-9966 ; Plan Check / Date ; Compliance Method ...... 'MICROPAS3 by Enercomp, Inc. ; Field Check/ Date Climate Zone........... 1.5 --------------------- =a=sxsasxsxsxa=sxax=xsx=xxxax=x=x=x=xxxxx=x=xxx=xxaxax=xs=sxsxs=nxsxsxs=.x=x=xx MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -WATER HEATING ; User#-MP1325 User -ENERGY CONSULTING GROUP Run-PACIFIC-------------------------------------------------------------------------------- ; WORKSHEET ONE: STORAGE GAS OR STORAGE ELECTRIC A. EQUIPMENT DATA ----------------- 1. Water heater type....... Storage, Electric. 2. Manufacturer............ WATERMISER 40FESL 3. Model number............ 4. Ignition device......... 5. Tank volume. .......... 6. Recovery efficiency..... 7. Sta-ndby loss............ S. Rated Input.............. 9. Number of Heaters....... 10.Insulation Jacket....... n/a 37 gal .99 percent x 0.01 .0082 percent/hour x 0.01 15358.5 Btu/hr 1 No B. OPERATING DATA ----------------- 1. Climate Zone.. 15 2. Water heating budget.... 18700 kBtu/yr/unit 3. Tank set temp............ 140 F 4. Water main temp......... 70 F S. Daily hot water load.... 50 gal 6. Ambient air temp........ 72.6 F 7. Adj. Standby Losses..... .0082 S. No. dwelling units ...... 1 9. Pump power............... O Watts (0 Watts controller.) 10.Pumping energy.......... 0 Watt-h.r/yr'(24 hr per day) C. WATER HEATING ENERGY CREDITS ------------------ ------ 1. Credit Name............ Recovery 2... Annual savings.......... 28.05 kBtu/yr/unit D. ANNUAL WATER HEATING ENERGY 1. Recovery load........... 10539 kBtu/yr 2. Recovery energy......... 7813 kBtu/yr 3. Standby loss energy..... 1392. kBtu/yr 4. -Pumping energy.......... 0 kBtu/yr source 5. Total energy..,.......... 27614 kBtu/yr/unit source 6. Comparison .............. -8914 kBtu/yr/unit source 7.. Points. ............ .. -14 8. Water Heating E 'Energy Use 2.1.97 kStu/yr/sf (D5 x B8),/ 1257 sf HVAC SIZING Page 1 HVAC Project Title.......... PACIFIC• Date........ 01/07/92 Pr,o.ject Address........ LA OUINTA --------------------- Documentation Author... W J FINNELL ; Building Permit # ; Company ................ ENERGY CONSULTING GROUP ; Telephone .............. 1-800-262-9966 ; Plan Check / Date ; Compliance"Method...... MICROPAS3 by Ene.rcomp, Inc. ; Field Check/ Date ClimateZone....,...... 15 --------------------- MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -HVAC SIZING User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC GENERAL INFORMATION Floor Area. ................ ............. 1257 sf Volume. .. 10936 cf Front Orientation........... Front Facing 90 deg (E) Sizing Location............ INDIO Latitude... ............. 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 1.12 F Summer Inside Design....... 78 F Summer Range... .......,.... 30 F Shading Used. ... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. CEC Maximum output applicable for gas central furnaces only HeatLng. Cooling Description ( Btuh ) ( Stuh ) Opaque Conduction and Solar...... 8667 4249 Glazing Conduction ............... 3624 3006 Glazing Solar ..................... n/a 5130 Infiltration.............. ...... 6449 3822 Internal Ga.i.n..................... n/a 2550 Ducts ......................... .. 1876 1876 Sensible Load. ......... .......... 20636 20631 Latent Load ...................... - n/a 41.26 ----------- Total Load ----------- 20636 24758 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. CEC Maximum output applicable for gas central furnaces only MANDATORY (MEASURES CHECKLIST: RESIDENTIAL Page '1 MF-1R =s=xcxxxxxx-x_cxxx=x=xxx=xxx==x===xx=xa=xxxx=x:xxx=x===x=xx=xx===xxxxx=xx=xxxnx Project Title.......... PACIFIC Date........ 01/07/92 Project Address., ...... :LA QUINTA --------------------- Documentation Author... W J FiNNELL ; Building Permit # ; Company ................ ENERGY CONSULTING GROUP Telephone .............. 1-800-262-9966 ; Plan Check / Date ; Compliance Method...... MICROPAS3 by EnercomP, Inc. ; Field Check/ Date ; ClimateZone........... 15 --------------------- MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM MF -1R User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC ; -------------------------------------------------------------------------------- Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all. parties as binding minimum component performance specifications for the mandatory measures' whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- Design- Enforce- er ment * 2-5352(a): Minimum ceiling insulation R-19 weighted average. 2-5352(`b): Loose fill insulation manufacturers labeled R -Value. * 2-5352(c): Minimum wall insulation in framed walls R-11 weighted average (does not apply to exterior mass walls). 2-5352(k): Slab edge insulation - water absorption rate no greater than 0..3%, water vapor transmission rate no greater than 2.0 perm/inch. 2-5311: Insulation specified or installed meets CEC quality standards. Indicate type and form. 2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16. 2-5317: Infiltration/Exfi.l.t:ration Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Doors and windows certified. c. Doors and windows weatherstrippedi all joints and penetrations caulked and sealed. 2-5352(e): Special infiltration barrier installed to comply with Sec. 2-5351 Meets CEC quality standards. 2-5352;( d ): Installat ,on of Fireplaces 1. Masonry and factory -built fireplaces have: a. Tight fitting, closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed- MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R Project Title.......... PACIFIC Date........ 0.1/07/92. ---- -------------- --------- MICROPA53 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM MF -1R II User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC ------------------------------------------------------------------------------- HVAC AND PLUMBING SYSTEM MEASURES --------------------------------- Design- Enforce - or ment 2-5352(g) and 2-5303: Space conditioning equipment sizing: attach calculations. 2-5352(h) and 2-5315: Setback thermostat on all applicable heating systems. * 2-5316(a): Ducts constructed, instal.led,and insulated per Chapter 10, 19.76'UMC. 2-5316(b): Exhaust systems have damper controls. 2-5314(c): Gas-fired space heating equipment has intermittent ignition devices. 2-5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. 2-5352(i ): Water heater insulation blanket (R-12or greater) for storage and backup tanks for solar water heating systems (first S feet of pipes closest to tank insulated to R-.3 or greater). 2-5312(Exception I): Pipe insulation on steam and steam condensate return and recirculating piping. 2-5318(d): Swimming Pool Heating 1. System has: a. On/off switch on heater. b. Weatherproof instruction plate on heater. c. Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3. Pool cover. 4. Time cloak. 5. Directional water inlet. LIGHTING'AND APPLIANCE MEASURES Design- Enforce- er ment 2-5352(j): Lighting - 25 lumens/watt or greater for general lighting in kitchens and bathrooms. 2-531.4(c): Gas fired appliances equipped with intermittent ignition devices. 2-5314(a): Refrigerators, refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the CEC.