13-0288 (AR)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 13-00000288
Property Address: 50565 EL DORADO DR
APN: 777-290-007-
- -
Application description: ADDITION - RESIDENTIAL
Property Zoning: LOW DENSITY
RESIDENTIAL
Application valuation: 69000
Applicant:/
Architect oglneer:
A
VOICE (760) 777-7012
FAX (760) 777-7011
BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 5/07/13
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B License No.: 805021
Date: �� Contractor::
{�•���\ OWN -BUILDER DECLARATION
1 hereby affirm under penalty of perjury that I a ex pt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044,. Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
( 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penally of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPE:PNI IT
Owner:
MADRIGRANO GLENN R SR. TRUST
4515 13TH ST
KENOSHA, WI 53144
Contractor:
WHITLEY'S CONSTRUCT
77775 JACKAL VE
PALM DESERT,
(760)341-9480
Lic. No.: 8050 MAY p7 2013
pF LA QUINTA
WORK R S COMPENSATION DECLARATION
1. hereby affirm under penalty of perjury one of the following declarations:
have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier QBE INSURANCE Policy Number EQB0200792
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Laborod , I shall forthwith comply with those provisions.
,Date:-. 11 -Applicant:
WARNING: FAILURE TO -SECURE WORKERS' COMP TION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100.000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Ouinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation. -
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter upon the above-mentioned pro er for inspection Wposes.
Date:S�.7�►3 Signature -(Applicant o�nU:
Application Number .
. . . . 13-00000288
' -----= Structure Information
EXIST 3969 SF SFD
-----
Other struct info . .
. . . CODE EDITION 2010
# BEDROOMS
1.00
FLOOD ZONE NO
----------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
315.00
Permit . . .
BUILDING PERMIT
Additional desc .
Permit Fee
500.00 Plan Check Fee
325.00
Issue Date
Valuation . . . .
69000
Expiration Date
11/03/13
Qty Unit Charge
Per
Extension
BASE FEE
414.50
19.00 4.5000
------------------ -----------------
THOU BLDG 50,001-100,000
85.50
. . . . . ..
ELECT - ADD/ALT/REM
Additional desc .
Permit Fee . . . .
127.64 Plan Check Fee
31.91
Issue Date . . . .
Valuation
0
Expiration Date
11/03/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
3154.00 .0350
ELEC NEW RES - 1 OR 2 FAMILY
110.39
3.00 .7500
----------------------------------------------------------------------------
PER ELEC DEVICE/FIXTURE 1ST 20
2.25
Permit
MECHANICAL
Additional desc .
Permit Fee . . . .
42.00 Pian Check Fee
10.50
Issue Date
Valuation . . . .
0
Expiration Date
.11/03/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
6.00 4.5000
----------------------------------------------------------------------------
EA MECH VENT INST/ DUCT ALT
27.00
Permit . . .
PLUMBING
Additional desc .
Permit Fee . . . .
36.00 Plan Check Fee
9.00
Issue Date . . . .
Valuation . . . .
0
Expiration Date
11/03/13
Qty Unit Charge
Per
Extension
LQPERAIIT
LQPmu-r
Application Number . . . . . 13-00000288
Permit . . . . . . PLUMBING
Qty Unit Charge Per
Extension
BASE FEE
15.00
3.00 6.0000 EA PLB FIXTURE
18.00
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
----------------------------------------------------------------------------
Special'Notes and Comments
315 sf CASITA W/ BATHROOM ADDITION AT
FRONT YARD. 2010 CODES. ARCHITECT:
CHARLES GARLAND C11991. 18 FRONT SETBACK
PER MA 2013-664.
--------------------------------------------------------------
Other Fees . . . . . . . . BLDG STDS ADMIN (SB1473) -
--------------
3.00
ENERGY REVIEW FEE
32.50
STRONG MOTION (SMI) - RES
6.90
Fee summary Charged Paid Credited
Due
Permit Fee Total 705.64 .00 .00
705.64
Plan Check Total 376.41 .00. .00
376.41
Other Fee Total 42.40 .00 .00
42.40
Grand Total 1124.45 .00 .00
1124.45
LQPmu-r
Bin.#
CI Of La Q(Iffltd
Butting a Safety Divliion
P.O. Box 1504,78195 Calle Tampico
4.Quinta, CA 92253 - -(760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
• 028
Project Address: b Owner's Name:
A. P. Number. Address: S.
Legal Description: City, ST, Zip: vf'
Contractor: `� Telephone: %
Address: % R Project Description: ,e
City, ST, Zip: fG /� tC✓GR igo'rT r.my" Pd
Telephone: .
/
State Lie. #: Q City Lie. #;
Arch, Bngn, Designer: e�4"s
Address:
City, ST, Zip:
Telephone:
State Lie. #:
Construction Type: , Occupancy:
Project type (circle one): New Add'a Alter Repair Demo
Sq. Ft.: # Stories: / # Units:
Name of Contact Person: J �� r
Telephone # of Contact Person: „_
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS UNE
N
Submittal
Req'd
Recd
TRACMG PERMIT FEES
Plan Sets
Plan Check submitted 15 Item Amount
Structural Calcs
Reviewed, ready fo corrections Plan Check Deposit. .
Truss Calls.
Called Contact Person Plan Check Balance
Title 24 Calls.
Plans picked up jb;wd '11 . Constriction
Flood plain plan
Plans resubmitted • . M.I fil al
Gi ading plan
I
2•! Review, ready for correctia usue i Electrical
Subeoatactor List
Called Contact P bs Plumbing
Grant Deed
Plans picked up S.M.L
H.O.A. Approval
Plans resubmitted Grading
IN ROUSE
Review; ready for corrections!issue Developer Impaet Fee
Planning Approval
Called Contact Person A.I.P.P.
Pub. Wks. Appr '
Date of permit issue
School Fees
TotalPermit Fees
els(. Fa0Af0' SA- '" - � . 2 .
2j'Z`� 13 "T%Y� Sf Cit,Q �d. J'�+��aee�� •
&,t
V
19/2009/THU 03:40 PM The Monarch Group FAX No,760 776 5111
MOUNTAIN VIEW
COUNTRY CLUB
at La Quinta
March 10, 2009
Glenn Madrigrano
4515 13th Street
Kenosha, WI 53144
Re: Architectural Request
50-565 EI Dorado Dr.
Dear Mr. Madrigano:
P. 001/001
Li
;I
MAR 2 5 2009 j
The Architectural/Landscape Committee of the Mountain View Country Club
Homeowners' Association have reviewed the plans to alter your garage door per
the application submitted. The committee is pleased to inform you that it has
approved the plans.
Thank you for your patience and understanding during this approval process. If
there are any questions please contact me at 760-7765100 ext. 351.
Sincerely,
FOR THE BOARD OF DIRECTORS
MOUNTAIN VIEW COUNTRY CLUB
Bill Clifford
Association Manager
enclosure
cc: Board of Directors
Unit File
r
Coachelha Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA: -
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMMAND. AMOUNT:
DATE:
RECEIPT:
CHECK#:
INITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: Mountain Views
Owner's Name: Glen & Barbara Madrigrano
Project Address: 50-565 EI Dorado Dr., LaQuinta
Project Description: Addition to attached Casita
APN: 777-290-007 Tract #:
Type of Development: Residential XX
Total Square Feet of Building Area:
Commercial
315
Date: April 11, 2013
Phone No.
Lot #'s:
Industrial
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authors to sign on behalf of the owner/developer.
Dated: April 11, 2013 Signature:
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE OJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Project Agreement Existing Not Subject to Fee
17620 65995 Approval Prior to 1/1/87 Requirement
Number of Sq.Ft.
Amount per Sq.Ft.
Amount Collected
315
$0.00
$0.00
Building Permit Application Completed: Yes/No
By: Elsa F. Esqueda, Director of Facilities and Maintenance
Note:
Pursuant to AB 181 any room additions or enclosures of 500
sq. ft. or less are exempt from developer fees. Any mobile
homes being relocated within the same school district's
jurisdiction are exempt from developer fees.
Certificate issued by: Laurie Howard, Secretary Signature: w alll—k
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
MV:chuydoes/devfees/certificate of compliance form updated 3-2007 11/2010
EsGil Corporation
In Partnership with Government for Building Safety
DATE: 04,/18/13
JURISDICTION: La Quinta
PLAN CHECK NO.: 13-0288
PROJECT ADDRESS: 50565 El Dorado
SET: II
❑ ANT
❑ QLRIS.
❑ PLAN REVIEWER
❑ FILE
PROJECT NAME: Room Addition for Madrigrano Residence
® The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
❑ The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
❑ The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
❑ The applicant's copy of the check list has been sent to:
® EsGil Corporation staff did not advise the applicant that the plan check has been completed.
❑ EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Email:
Mail Telephone Fax In Person
❑ REMARKS:
By: Ray Fuller Enclosures:
EsGil Corporation
❑ GA ❑ EJ ❑ PC (E) 04/15/13
Fax #:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
April 29, 2013
APIP 235 LLC
MR & MRS GLENN MADRIGRANO
4515 13th STREET
KENOSHA, WI 53144
RE: Architectural Submittal for 505.65 EL DORADO DRIVE
Account #585298
Dear Homeowner:
The Architectural Review Committee for MOUNTAIN VIEW HOA has reviewed and APPROVED your architectural
submittal for the installation of a Casita Addition per the plans submitted.
All construction must commence within 120 days of this approval letter. If construction has not been commenced
within the 120 days, such approval shall be deemed withdrawn.
ARC approval of plans shall not constitute a representation, warranty, or guarantee that such plans and specifications
comply with engineering design practices or zoning and building ordinances, or other governmental agency regulations
or restrictions. The ARC shall not be responsible for reviewing, nor shall its approval of any plans or design, be
deemed approved from the standpoint of structural safety or conformance with building or other codes. By approving
such plans and specifications, neither the ARC, the Members thereof, the Association, any Member thereof, their Board
of Directors, any Members thereof, or the Declarant assumes any liability or responsibility therefore or for any defect in
the construction or improvement from such plans or specifications. As provided in the CC&R's neither the ARC, the
Association, the Board of Directors or the Association or any Members thereof, not the Declarant or Developer shall be
liable to any Member, Owner, Occupant, or other person or entity for any damage, loss or prejudice s uffered or
claimed on account of (1) the approval or disapproval of any plans, drawings, or specifications, whether or not
defective, or (2) the con_ struction'or performance of any work whether or not pursuant to the approved plans, drawings,
or specifications.
Your patience and cooperation with the architectural review process is appreciated. If you have any questions, please
contact the association at (760) 776-5100.
Sincerely,
On behalf of the MOUNTAIN VIEW HOA Architectural Review Committee
Jamie Hansen
The Management Trust - Monarch Group Division
cc: Board of Directors
Unit File
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
MADRIGRANO's Residence
50565 EI Dorado Dr.
La Quinta, Ca 92253
RECEIVED
MAR 15 2013
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
Project Designer:
GLS Architecture Group
74991 Joni Dr. # 9
Palm Desert, Ca 92211
760.340.3528
Report Prepared by:
ARMANDO CHAVEZ
GLS Architecture Group
74491 JONI DR SUITE #9
PALM DESERT, CA 92260
760 278.1.840, .
Job Number:
2013 -GLS -09
Date:
3/6/2013 .
I
0.
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
BY.
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 5.1 by EnergySoR User Number: 5553 RunCode: 2013-03-06T13:03:39 ID: 2013 -GLS -09
.... .TABLE QF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
EnergyPro 5.1 by EnergySoft Job Number: ID: 2013 -GLS -09 User Number: 5553
1
2
3
10
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
MADRIGRANO's Residence
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family 0 Existing+ Addition/Alteration
Date
3/6/2013
Project Address
50565 E/ Dorado Dr. La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,284
Addition
315
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes El No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity ( Features see Part 2 of 5
Status
Slab Unheated Slab -on -Grade None 3,969 Perim = 287'
Existing
Roof Wood Framed Attic R-30 3,953
Existing
Wall Wood Framed
R-19 6,615
Existing
Slab Unheated Slab -on -Grade
None 315 Perim = 58'
New
Roof Wood Framed Attic
R-38 315
New
Wall Wood Framed
R-21 1,393
New
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades
Status
Skylight 0.5 0.430
0.30 none none None
New
Skylight 16.0 0.550
0.67 none none None
Existing
Right (N) 62.9 0.510
0.34 none none Bug Screen
Existing
Right (N) 20.0 0.510
0.66 none none Bug Screen
Existing
Front (E) 92.3 0.510
0.34 none none Bug Screen
Existing
Left (S) 121.0 0.510
0.34 none none Bug Screen
Existing
Left (S) 20.0 0.400
0.35 none none Bug Screen
New
Rear (W) 309.4 0.510
0.34 none none Bug Screen
Existing
Right (N) 8.0 0.510
0.66 none none Bug Screen
New
Front (E) 52.7 0.400
0.35 none none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff
Cooling Min. Eff Thermostat
Status
2 Central Furnace 78% AFUE
Split Air Conditioner 9.7 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value
Status
EXISTING Ducted
Ducted Attic, Roof Ins 4.2
Existing
WATER HEATING
Ot . Type Gallons Min. Eff Distribution
Status
Ener Pro 5.1 by Ener Soft User Number: 5553
RunCode: 2013-03-06T13:03:39 ID: 2013 -GLS -09
Pa e 3 of 12
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
MADR/GRANO's Residence
Building Type ® Single Family ❑ Addition Alone
1 ❑ Multi Family ® Existing+ Addition/Alteration
Date
3/6/2013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
Ener Pro 5.1 by Ener Soft User Number: 5553 RunCode: 2013-03-06713:03:39 ID: 2013 -GLS -09 Page 4of 12
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R
Project Name
Building Type 10 Single Family ❑ Addition Alone
Date
MADR/GRANO's Residence
❑ Multi Family m Existing+ Addition/Alteration
3/6/2013
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 10.06 8.60 1.45
Space Cooling 143.59 143.67 -0.08
Fans 25.22 25.11 0.11
Domestic Hot Water 8.44 8.44 0.00
Pumps 0.00 0.00 0.00
Totals 187.31 185.82 1.49
Percent Better Than Standard: 0.8%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 1,778 145
Fuel Available at Site: Natural Gas (S) 2,569 141
Raised Floor Area: 0 (1/11 1,778 309
Slab on Grade Area: 4,284 (N) 2,570 91
Average Ceiling Height: 10.0 Roof 4,284 17
Fenestration Average U-Factor: 0.50 TOTAL: 703
Average SHGC: 0.35 Fenestration/CFA Ratio: 16.4%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company GLS Architecture Group „
Address 74491 JONI DR SUITE #9 Name ARMANDO CHAVEZ 3%6/2013
City/ tate/ZiPALM DESERT, CA 92260 Phone 760 278.1840 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
D i er or Owner (per Business & Professions Code)
Com ny GLS Architecture Group
Address 74991 Joni Dr. # 9 Name -
City/State/Zip Palm Desert, Ca 92211 Phone 760.340.3528 igned /ense # Date
EnerqvPro 5.1 by Ene Soft User Number: 5553 RunCode: 2013-03-06713:03:39 ID: 2013-GLS-09 Pa e 5 of 12
CERTIFICATE OF COMPLIANCE:
Residential
(Part 4 of 5) CF -1 R
Project Name
MADRIGRANO's Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family . m Existing+ Addition/Alteration
Date
3/6/2013
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
I Factor Cavity Exterior I Frame Interiorl Frame Azm Tilt Status 4 Location/Comments
Slab
3,9691
0.730 None
0
180 Existing 4.4.7-A 1
Roof
3,9531
0.031 R-30
0
0 Existing 4.2.1-A20
Wall
1,9701
0.074 R-19
1 0
90 Existing 4.3.1-A5
Wall
1,176
0.074 R-19
90
90 1 Existing 4.3.1-A5
Wall
2,001
0.074 R-19
180
90 1 Existing 4.3.1-A5
Wall
1,469
0.074 R-19
270
901 Existing 4.3.1-A5
Slab
315
0.730 None
0
180 New 4.4.7-A1
Roof
315
0.025 R-38
0
0 New 4.2.1-A21
Wall
509
0.069 R-21
0
90 New 4.3.1-A6
Wall
4571
0.069 R-21
90
90 New 4.3.1-A6
Wall
427
0.069 R-21
180
90 New 4.3.1-A6
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC
Azm Status
Glazing Type Location/Comments
1
Skylight
0.5 0.430 NFRC
0.30 NFRC
0 New
Solatube
2
Skylight
16.0 0.550 Default
0.67 Default
0 Existing
Double Non Metal Clear
3
Window
2.3 0.510 NFRC
0.34 NFRC
0 Existing
General Aluminum Company
4
Window
2.3 0.510 NFRC
0.34 NFRC
0 Existing
General Aluminum Company
5
Window
2.3 0.510 NFRC
0.34 NFRC
0 Existing
General Aluminum Company
6
Window
20.0 0.510 NFRC
0.66 1 NFRC
0 Existing
Pittsburgh Coming GB 12x12
7
Window
8.0 0. 5101 NFRC
0.34 NFRC
0 Existing
General Aluminum Company
8
Window
48.0 0.510 NFRC
0.34 NFRC
0 Existing
General Aluminum Company
9
Window
9.3 0.510 NFRC
0.34 NFRC
90 Existing
General Aluminum Company
10
Window
9.3 0.510 NFRC
0.34 NFRC
90 Existing
General Aluminum Company
11
Window
24.0 0.510 NFRC
0.34 NFRC
90 Existing
General Aluminum Company
12
Window
13.7 0.510 NFRC
0.34 NFRC
90 Existing
General Aluminum Company
13
Window
36.0 0.510 NFRC
0.34 NFRC
90 Existing
General Aluminum Company
14
Window
12.5 0.510 NFRC
0.34 NFRC
180 Existing
General Aluminum Company
15
Window
12.5 0.510 NFRC
0.34 NFRC
180 Existing
General Aluminum Company
16
Window
24.0 0.510 NFRC
0.34 NFRC
180 Existing
General Aluminum Company
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
HqA Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len Hat Dist Len H t
1
None
1.00
2
None
1.00
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
_,Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
Bug Screen
0.76
Ener
Pro 5.1 by Ener Soft User Number: 5553 RunCode: 2013-03-06T13:03:39 ID: 2013 -GLS -09 Pa e 6 of 12
CERTIFICATE OF COMPLIANCE: Residential
(Part 4 of 5) CF-1 R
Project Name
MADR/GRANO's Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
3/6/2013
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Tvpe Area
U-Factor
SHGC2
Azm Status
Glazing Type Location/Comments
17
Window 24.0
0.510 NFRC
0.34 NFRC 180 Existing
General Aluminum Company
18
Window 48.0
0.510 NFRC
0.34 NFRC 180 Existing
General Aluminum Company
19
Window 20.0
0.400 NFRC
0.35 NFRC 180 New
U 0.40 / S 0.35 Z15
20
Window 8.0
0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
21
Window 36.0
0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
22
Window 8.0
0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
23
Window 36.0
0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
24
Window 64.0
0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
25
Window 10.7
0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
26
Window 64.0
0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
27
Window 10.7
0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
28
Window 36.0
0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
29
Window 36.0
0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
30
Window 8.0
0.510 NFRC
0.66 NFRC 0 New
Pittsburgh Coming GB 12x12
31
Window 6.7
0.400 NFRC
0.35 NFRC 90 New
U 0.40 / S 0.35 Z15
32
Window 18.0
0.400 NFRC
0.35 NFRC 90 New
U 0.40 / S 0.35 Z15
(1) Ll-Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
H t Wd
Ove hang
Len H t LExt
Left Fin Right Fin
RExt Dist Len H t Dist Len H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
31
Bug Screen
0.76
32
JBug Screen
0.76
Ener
Pro 5.1 by Ener Soft
User Number: 5553
RunCode: 2013-03-06T13:03:39 ID: 2013-GLS-09 Pa e 7 of 12
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R
Project Name
MADRIGRANO's Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family Ea Existing+ Addition/Alteration
Date
3/6/2013
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Type Area LI-Factor SHGCz Azm Status Glazing Type Location/Comments
33 Window 18.0 0.400 NFRC 0.35 NFRC 90 New U 0.40 / S 0.35 Z15
34 Window 5.0 0.400 NFRC 0.35 NFRC 90 New U 0.40 / S 0.35 Z15
35 Window 5.0 0.400 NFRC 0.35 NFRC 90 New U 0.40 / S 0.35 Z15
(1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR.SHADING DETAILS
Window Ove hang Left Fin Right Fin
ID Exterior Shade Type SHGC H W Wd Len H t LExt RExt Dist Len H t Dist Len H t
33 Bug Screen 0.76
34 Bug Screen 0.76
35 Bug Screen 0.76
Ener Pro 5.1 by EnergySoft User Number: 5553 RunCode: 2013-03-06713:03:39 ID: 2013-GLS-09 Pa e 8 of 12
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R
Project Name
MADR/GRANO's Residence
Building Type 2 Single Family ❑ Addition Alone
❑ Multi Family 0 Existing+ Addition/Alteration
Date
3/6/2013
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existing Altered Removed Volume Year Built
EXISTING EXISTING
3,969
39,690 2004
Addition
315
3,150
Totals 315 3,969 01 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
EXISTING 2 Central Furnace
78% AFUE Split Air Conditioner 9.7 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
EXISTING Ducted
Ducted Attic, Roof Ins 4.2
❑ Existing
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
(Btu h)
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
Kitchen Pipe Ins
40,000
50
0.58
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
(ft)
C
0
i�
�a N
a
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty. HP
Plenum Outside Buried
Ener Pro 5.1 by Ener Soft User Number: 5553
RunCode: 2013-03-06T13:03:39 ID: 2013 -GLS -09
Page 9 of 12
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
MADR/GRANO's Residence
Date
3/6/2013
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/orcooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation havin ' an installed thermal resistance of R-12 or greater.
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-13.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and•indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of•Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
§1500)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoR User Number: 5553 RunCode: 2013-03-06713:03:39 ID: 2013 -GLS -09 Page 10 of 12
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
MADRIGRANO's Residence
1 3/6/2013
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support plafforms may
contain ducts. Ducts installed in cavities and support plafforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable re uirements o §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is -internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number: 5553 RunCode: 2013-03-06713:03:39 ID: 2013 -GLS -09 . Page 11 of 12
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
MADR/GRANO's Residence
1 3/6/2013
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number: 5553 RunCode: 2013-03-06713:03:39 ID: 2013 -GLS -09 Page 12 of 12