11-0215 (AR)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 11-00000215
Property Address: 50805 EL DORADO DR
APN: 777-290-015- - -
Application description: ADDITION - RESIDENTIAL
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 50000
Tiht 4 4 Q"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner:
KEEGAN EDWARD G/MARJORIE L
50805 EL DORADO DR
LA QUINTA, CA 92253
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: . 4/06/11
d Contractor:
D
Applicant: Architect or Engineer:
WHITLEY I S CONSTRUCTION CORPRTN
77775 JACKAL DRIVE
APR 06
PALM DESERT, CA 92211
ql�
2011
(760)341-9480
LiC. No.: 805021
CYOF
FIMQ CE K)EPT
-----------------------------------------------------------------------------7-------------------
LICENSED CONTRACTOR'S DECLARATION
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury t at 1 am licensed under provisions of Chapter 9 (commencing with
I hereby affirm under penalty of perjury one of the following declarations: '
Section 7000) of Division 3 of the Bus, ass and.Prof ionals Code, and my License is in full force and effect.
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
License Class: B License No.: 805021
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
L /
Date: �!� +/ Contractor: -
/ Issued.
Y I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
/— Code, for the performance of the work for which this permit is issued. My workers' compensation
OWNER -BUILDER DECLARATION
insurance carrier and policy number are:
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
Carrier NATIONAL UNION Policy Number WC007200169
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
person in any manner so as to become subject to the workers' compensation laws of California,
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
and agree that, if I sh d ecome subject to the workers' compensation provisions of Section
License Law'(Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
3700 o_ f the Labor C e shall f hwi comply with those provisions. '
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
e: .^(S plicant:
(_ I I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
WARNING: FAILURE TO SEC UR WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
and who does the work himself or herself through his or her own employees, provided that the
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
-SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
one year of completion, the owner -builder will have the burden of proving that he or she did not build or.
improve for the purpose of sale.).
APPLICANT ACKNOWLEDGEMENT
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
conditions and restrictions set forth on this application.
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
1. Each person upon whose behalf this application is made, each person at whose request and for
pursuant to the Contractors' State License Law.). -
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
(_ 1 I am exempt under Sec. , B.&P.C. for this reason
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
16
LQPERMIT
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state *abotion is correct. I .agree to comply with all
city and county ordinances and state laws relatingn, and hereby authorize representatives
of Shin count to enter upon the above-mentioned purposes.
Date: �re (Applicant or Agen
-\
LQPERMIT
Application Number . . . . . 11-00000215
Permit
BUILDING PERMIT
Additional
desc
315 SF BEDRM/BATH ADDTN
Permit Fee
. . . .
414.50
Plan Check
Fee
269.43
Issue Date
. . . .
Valuation
50000,
Expiration
Date
10/03/11
Qty Unit Charge
Per
Extension
BASE FEE
252.00
25.00
----------------------------------------------------------------------------
6.5000
THOU BLDG 25,001-50,000
162.50
Permit
. . .
ELECT - ADD/ALT/REM
Additional
desc .
Permit Fee
. . .
26.03
Plan Check
Fee
6.51
Issue Date
Valuation
. .
0
Expiration
Date
10/03/11
Qty Unit Charge
Per
Extension
BASE FEE
15.00
315.00
.0350
ELEC NEW
RES - 1 OR 2
FAMILY
11.03
Permit
. . .
GRADING PERMIT
Additional
desc .
Permit Fee
. . . .
15.00
Plan Check
Fee.
.00
Issue Date
. . . .
Valuation
0
Expiration
Date:
10/03/11
Qty. Unit Charge
Per
Extension
----------------------------------------------------------------------------
BASE FEE
15.00•
Permit
. . .
MECHANICAL
Additional
desc .
Permit Fee
. . . .
24.00
Plan Check
Fee
6..00
Issue Date
. . . .
Valuation
0
Expiration
Date
10%03/11
Qty Unit Charge
Per
Extension
BASE FEE
15.00
2.00
---------------------------=------------------------------------------------
4.5000
EA MECH VENT
INST/ DUCT ALT
9.00
Permit
PLUMBING
Additional
desc .
Permit Fee
. . . .
33.00
Plan Check
Fee
8.25
Issue Date
. . . .
Valuation.
0
Application Number . . . . . 11-00000215 .
Permit . . . . . PLUMBING
Expiration Date 10/03/11
Qty Unit Charge Per
Extension
BASE FEE
15.00
3.00 6.0000 EA PLB FIXTURE
18.00
----------------------------------------------------------------------------
Special Notes and Comments
315 SF BEDROOM & BATH ADDITION TO
EXISTING SINGLE FAMILY RESIDENCE. 18.5
FT FRONTYARD SETBACK APPROVED PER -MA
2011-625. R-3 OCC. TYPE V -B CONSTR.
----------------------------------------------------------------------------
Other Fees . . . . . . . . BLDG STDS ADMIN (SB1473)
2.00
ENERGY REVIEW FEE
26.94
STRONG MOTION (SMI) - RES
5.00'
Fee summary Charged Paid Credited
Due
--------------------- ------ --------------------
Permit.Fee.Total 512.53 .00 .00.
512.53
Plan Check Total .290.19 .00 .00
290.19
Other Fee Total 33.94 .00 .00
33.94
Grand Total 836.66 .00 .00
836.66
LQPERMIT
3�r Vic• -� �i� d�-A-� Jl�� J � r R,� �.1 �� �� t
5 57R • rY
City of La Quinta
Building a Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address:
Owner's Name: if,U Kee, g Gc
A. P. Number:
Address:,ro
Legal Description:
City,ST Zip:
Contractor:
/:::
;.'<>:'::"::"s;:•'•>:'>:':>:<s<:<4s:.;>
Address:
Project Description: 315 A d T �
City, ST, Zip:
f�e D O tn
Telephone:
:.::>::>::;.:> :::;::::; •;:. i.:;: : >:: is <::>;.:.:
State Lic. # :
City Lic. #;
1
%%� 2, M/ • 2 S yryd..# pG4
Arch., Engr., Designer:
Address:
City, ST, Zip: 4
Telephone:
State Lic. #:;<.<>Pro'ect
Construction Type: Occupancy:
a circle one : New Add'n Alter Re air Demo
J tYP ) PName
I
of Contact Person: ��(� ,� �_Sq.
Ft.:
Stories:
# Units: , r
Telephone # of Contact Person: `
Estimated Value of Projec o D rJ f�
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets
J11
Plan Check submitted
u
Item Amount
Structural Calcs.
311
Reviewed, ready r corrections
17 t
Plan Check Deposit
n�
O2
Truss Calcs.
j.2
Called Contact Person
I
Plan Check Balance.
Title 24 Calcs.
3//
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2°" Review, ready for corrections ssue
y
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Pians resubmitted
Grading
IN HOUSE:-
'"' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
3�r Vic• -� �i� d�-A-� Jl�� J � r R,� �.1 �� �� t
5 57R • rY
\1'
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
0 (760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVELTWOAMOUNT:
MITIGATION AMOUNT:
COMM/IND. AMOUNT:
DATE:
RECEIPT:
CHECK#:
INITIALS:
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: Mountain View, Date: March 30, 2011
Owner's Name: Ed Keegan Phone No.
Project Address: 50-805 El Dorado Dr., LaQuinta, CA
Project Description: Bedroom w/bath addition to existing single family
APN: 777-290-015
Tract #:
Lot #'s:
Type of Development: Residential iXX Commercial Industrial
Total Square Feet of Building Area: 315 sq. ft.
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authQ{ized to sign on behalf of the owner/developer.
Dated: March 30, 2011 Signature: (/ 1Q
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE P OJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code
17620
Number of Sq.Ft.
Amount per Sq.Ft.
Amount Collected
Gov. Code Project
65995 Approval
315 sq. ft.
$ 0.00
$ 0.00
Agreement Existing Not Subject to Fee
Prior to 1/1/87 Requirement
Note: Pursuant to AB -181, any room additions of 500 square
feet or less on existing dwelling units are exempt from
developer fees. !Pursuant to AB -181, any mobile home being
relocated or replaced within our school district is exem i
from
_developer fees.
Building Permit Application Completed: Yes/No
By: Jamie T. Brown, Asst. Supt., Business Services
Certificate issued by: Laurie Howard, Secretary HI Signature: p�q jv 'C�iJ�7 X
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), oft he 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to,issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
MV:chnydocs'devfees/certificate ofcompliance Ibrm tablesfO USE.doc 1/16/03 T
MOUNTAIN VIEW
COUNTRY CLUB
at La Quinta
February 25, 2011
Edward Keegan
50-805 EI Dorado
La Quinta, CA 92253
Re: Architectural Request
50=805 EI Dorado
Dear Mr. Keegan:
The Architectural/Landscape Committee of the Mountain View Country Club
Homeowners' Association have reviewed the plans to install a casita to your
home per the application submitted. The committee is pleased to inform you that
it has approved the application. Please note the following:
• Casita is approved even though encroaches into 25' setback as existing
garage is in same location extending further, therefore does not present a
problem.
Thank you for your patience and understanding during this approval process. If
there are any questions please contact me at 760-776-5100 ext. 351.
Sincerely,
FOR THE BOARD OF DIRECTORS
MOUNTAIN VIEW COUNTRY CLUB
Jamie Hansen, CCAM
Association Manager
cc: Board of Directors
Unit File
0
BUILDING ENERGY ANALYSIS REPORT
RECEIVED
MAR 2 3 2011
PROJECT:
Mr. & Mrs. KEEGAN's Residence
50805EI Dorado Dr.
La Quinta, Ca 92253
s
Project Designer:
GLS Architecture Gr \NG g�S %
74991 Joni Dr. # 9 ����� 04
1`pN
Palm Desert, Ca 922 1 R.�p NS -AVG
760.340.3528 FpR Gp 154i
Report Prepared by:
Santiago Lopez-Ocampo
Santiago Lopez-Ocampo
P.O: Box 1018
La Quinta, Ca 92247
760.485.8927
Job Number:
lg022511
Date:
3/22/2011
The EnerP�o:comouter Erogram has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California -Gemmission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoff.coni.
EnergyPro 5.1 by Ener ySoft User Number: 5732 RunCode: 2011-03-22T11:49:05 ID: l 022511
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
EnergyPro 5.1 by EnergySoft Job Number: ID: Ig022511 User Number: 5732
1
2
3
11
14
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Mr. & Mrs. KEEGAN'S Residence
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
1312212011
Project Address
50805 EI Dorado Dr. La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,284
Addition
315
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft`) Features (see Part 2 of 5)
Status
Slab Unheated Slab -on -Grade None 3,190 Perim = 0'
Existing
Wall Wood Framed R-19 2,154
Existing
Roof Wood Framed Attic R-30 3,953
Existing
Door Opaque Door None 28
Existing
Slab Unheated Slab -on -Grade None 579 Perim = 0'
New
Wall Wood Framed R-21 3,395
New
Door Opaque Door None 24
New
Roof Wood Framed Attic R-38 315 Radiant Barrier
New
FENESTRATION U- Exterior
Orientation Area(ft2) Factor SHGC Overhang Sidefins Shades
Status
Right (N) 144.0 0.510
0.34 none none Bug Screen
Existing
Rear (W) 357.2 0.510
0.34 none none Bug Screen
Existing
Front (E) 92.3 0.510
0.34 none none Bug Screen
Existing
Skylight 16.0 0.550
0.67 none none None
Existing
Right (N) 36.0 0.510
0.34 none none Bug Screen
New
Left (S) 32.0 0.510
0.34 none none Bug Screen
Existing
Skylight 0.5 0.430
0.30 none none None
New
Front (E) 49.7 0.510
0.34 none none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff
Cooling Min. Eff Thermostat
Status
1 Central Furnace 78% AFUE
Split Air Conditioner 9.7 SEER Setback
Existing
1 Central Furnace 78% AFUE
Split Air Conditioner 9.7 SEER Setback
Existing
1 Central Furnace 78% AFUE
Split Air Conditioner 9.7 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value
Status
HVAC System - Zone 1 Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
HVAC System - Zone 2 Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
HVAC System - Zone 3 Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
WATER HEATING
Ot . Type Gallons Min. Eff Distribution
Status
Energ Pro 5.1 by EnergySoft User Number: 5732
RunCode: 2011-03-22711:49:05 ID: 1022511
Page 3 of 16
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Mr. & Mrs. KEEGAN'S Residence
Building Type ® Single Family 0 Addition Alone
1 O Multi Family ® Existing+ Addition/Alteration
Date
1312212011
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The DHW System A O Smith Water Products FPSH-75 is a non-NAECA large storage gas water heater. Verify DHW details.
The Existing Water Heater A O Smith Water Products FPSH-75 has an EF less than the Vintage Defaults. Field verification is required.
The Existing Furnace Default FAU/AC 1992 - 2005 has an AFUE less than the Vintage Defaults. Field verification is required.
The Existing Air Conditioner Default FAU/AC 1992 - 2005 has an SEER less than the Vintage Defaults. Field verification is required.
HIGH MASS Design - Verify Thermal Mass: 227.0 ft2 Covered Slab Floor, 3.500" thick at Zone 1
HIGH MASS Design - Verify Thermal Mass: 625.0 ft2 Exposed Slab Floor, 3.500" thick at Zone. 1
The Existing Furnace Default FAU/AC 1992 - 2005 has an AFUE less than the Vintage Defaults. Field verification is required.
The Existing Air Conditioner Default FAU/AC 1992 - 2005 has an SEER less than the Vintage Defaults. Field verification is required.
HIGH MASS Design - Verify Thermal Mass: 1,532.0 ft2 Covered Slab Floor, 3.500" thick at Zone 2
The Existing Furnace Default FAU/AC 1992 - 2005 has an AFUE less than the Vintage Defaults. Field verification is required.
The Existing Air Conditioner Default FAU/AC 1992 - 2005 has an SEER less than the Vintage Defaults. Field verification is required.
HIGH MASS Design - Verify Thermal Mass: 227.0 ft2 Covered Slab Floor, 3.500" thick at Zone 3
HIGH MASS Design - Verify Thermal Mass: 579.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 3
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
Ener Pro 5.1 by Ener Soft User Number: 5732 Run Code: 2011-03-22711:49:05 ID: 1022511 Page 4 of 16
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Mr. & Mrs. KEEGAN'S Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
3/22/2011
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HIGH MASS Design - Verify.Thermal Mass: 579.0 ft2 Exposed Slab Floor, 4.000" thick at Addition
The Roof R-38 Roof Attic w/Radiant Barrier includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as
specified in Residential Appendix RA4.2.2.
V
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
Ener Pro 5.1 by Ener Soft User Number: 5732 RunCode: 2011-03-22711:49:05 ID: 1 022511 Pae 5 of 16
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type [0 Single Family ❑ Addition Alone
Date
Mr. & Mrs. KEEGAN'S Residence
❑ Multi Family 0 Existing+ Addition/Alteration
3/22/2011
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 8.29 8.56 -0:27
Space Cooling 125.46 121.07 4.39
Fans 25.75 24.93 0.83
Domestic Hot Water 5.98 5.98 0.00
Pumps 0.00 0.00 0.00
Totals 165.48 160.53 4.95
Percent Better Than Standard: 3.0%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 811 142
Fuel Available at Site: Natural Gas (S) 1,047 32
Raised Floor Area: 0 (tM 786 357
Slab on Grade Area: 3,769 (N) 3,668 180
Average Ceiling Height: 10.7 Roof 4,284 17
Fenestration Average U -Factor: 0.51 TOTAL: 728
Average SHGC: 0.34 Fenestration/CFA Ratio: 17.0
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Santiago Lopez-Ocampo `ca*+L
3/22/2011
P.O. Box 1018 Santiago Lo ez-Ocam
Name ame o g p p
City/ tate/ZiLa Quinta, Ca 92247 Phone 760.485.8927 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents isrconsistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company GLS Architecture Group
Address 74991 Joni Dr. # 9 Name
City/State/Zip Palm Desert, Ca 92211 Phone 760.340.3528 Signed License # Date
Ener Pro 5.1 by Ener Soft User Number: 5732 RunCode: 2011-03-22T11:49:05 /D: 1 022511 Page 6 of 16
CERTIFICATE OF COMPLIANCE: Residential
(Part 4 of 5) CF-1 R
Project Name
Mr. & Mrs. KEEGAN'S Residence
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family G21 Existing+ Addition/Alteration
Date
1312212011
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Slab
227
0.730 None
0
180 Existing 4.4.7-Al
Zone 1
Slab
625
0.730 None
0
180 Existing 4.4.7-A 1
Zone 1
Wall
167
0.074 R-19
1 0
90 1 Existing 4.3.1-A5
Zone 1
Wall
521
0.074 R-19
270
90 Existing 14.3.1-A5
Zone 1
Wall
93
0.074 R-19
180
90 Existing 4.3.1-A5
Zone 1
Wall
197
0.074 R-19
90
90 Existing 4.3.1-A5
Zone 1
Roof
852
0.031 R-30
0
0 Existing 4.2.1-A20
Zone 1
Slab
1,532
0.730 None
0
180 Existing 4.4.7-A 1
Zone 2
Wall
219
0.074 R-19
270
90 1 Existing 4.3.1-A5
Zone 2
Wall
108
0.074 R-19
0
90 Existing 4.3.1-A5
Zone 2
Wall
94
0.074 R-19
180
90 Existing 4.3.1-A5
Zone 2
Wall
84
0.074 R-19
90
90 Existing 4.3.1-A5
Zone 2
Door
28
0.500 None
90
90 Existing 4.5.1-A4
Zone 2
Roof
1,516
0.031 R-30
0
0 Existing 4.2.1-A20
Zone 2
Slab
227
0.730 None
0
180 Existing 4.4.7-A 1
Zone 3
Slab
579
0.730 ;one
0
180 Existing 4.4.7-A1
Zone 3
FENESTRATION SURFACE DETAILS
ID
Type
Area U-Factor
SHGC
Azm Status
Glazing Type
Location/Comments
1
Window
24.0 0.510 NFRC
0.34 NFRC 0 Existing
General Aluminum Company
Zone 1
2
Window
24.0 0.510 NFRC
0.34 NFRC 0 Existing
General Aluminum Company
Zone 1
3
Window
48.0 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
Zone 1
4
Window
36.0 0.510 NFRC
0.34 NFRC 90 Existing
General Aluminum Company
Zone 1
5
Window
36.0 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
Zone 2
6
Window
8.0 0.510 NFRC
0.34 1 NFRC 270 Existing
General Aluminum Company
Zone 2
7
Window 1
36.0 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
Zone 2
8
Window
8.0 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
Zone 2
9
Window
64.0 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
Zone 2
10
Window
10.6 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
Zone 2
11
Window
64.0 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
Zone 2
12
Window
10.6 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
Zone 2
13
Window
48.0 0.510 NFRC
0.34 NFRC 0 Existing
General Aluminum Company
Zone 2
14
Window
9.3 0.510 NFRC
0.34 NFRC 90 Existing
General Aluminum Company
Zone 2
15
Window
9.3 0.510 NFRC
0.34 NFRC 90 Existing
General Aluminum Company
Zone 2
16
Window
13.7 0.510 NFRC
0.34 1 NFRC 90 Existing
General Aluminum Company
Zone 2
(1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
-Hqt Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
JBug Screen
0.76
16
JBug Screen
0.76
Ener
Pro 5.1 by Ener Sok User Number., 5732
RunCode: 2011-03-22711:49:05 ID: 1022511
Page 7 of 16
CERTIFICATE OF COMPLIANCE:
Residential
(Part 4 of 5) CF -1 R
Project Name
Mr. & Mrs. KEEGAN's Residence
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family [a Existing+ Addition/Alteration
Date
1312212011
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Wall
133
0.074 R-19
0
90 Existing 4.3.1-A5
Zone 3
Wall
158
0.074 R-19
270
90 Existing 4.3.1-A5
Zone 3
Wall
640
0.074 R-19
180
90 Existing 4.3.1-A5
Zone 3
Wall
2101
0.074 R-19
90
90 Existing 4.3.1-A5
Zone 3
Roof
1,585
0.031 R-30
0
0 Existing 4.2.1-A20
Zone 3
Slab
579
0.730 None
01
180 New 4.4.7-A 1
Zone 3
Wall
3,056
0.069 R-21
0
90 New 4.3.1-A6
Zone 3
Door
24
0.500 None
0
90 New 4.5.1-A4
Zone 3
Wall
188
0.069 R-21
180
90 New 4.3.1-A6
Zone 3
Wall
150
0.069 R-21
90
90 New 4.3.1-A6
Zone 3
Roof
315
0.025 R-38
0
0 New 4.2.1-A21
Zone 3
FENESTRATION SURFACE DETAILS
ID
Type I
Area U -Factor
SHGC2
Azm Status
Glazing Type
Location/Comments
17
Window
24.0 0.510 NFRC
0.34 NFRC
90 Existing
General Aluminum Company
Zone 2
18
Skylight
16.0 0.550 Default
0.67 Default
0 Existing
Double Non Metal Clear
Zone 2
19
Window
48.0 0.510 NFRC,
0.34 NFRC
0 Existing
General Aluminum Company
Zone 3
20
Window
12.5 0.510 NFRC
0.34 NFRC
0 New
General Aluminum Company
Zone 3
21
Window
12.5 0.510 NFRC
0.34 NFRC
0 New
General Aluminum Company
Zone 3
22
Window
11.0 0.510 1 NFRC
0.34 NFRC
0 New
General Aluminum Company
Zone 3
23
Window
36.0 0.510 NFRC
0.34 NFRC
270 Existing
General Aluminum Company
Zone 3
24
Window
36.0 0.510 NFRC
0.34 NFRC
270 Existing
General Aluminum Company
Zone 3
25
Window
2.3 0.510 NFRC
0.34 NFRC
180 Existing
General Aluminum Company
Zone 3
26
Window
2.3 0.510 NFRC
0.34 NFRC
180 Existing
General Aluminum Company
Zone 3
27
Window
2.3 0.510 NFRC
0.34 NFRC
180 Existing
General Aluminum Company
Zone 3
28
Window
17.1 0.510 NFRC
0.34 NFRC
180 Existing
General Aluminum Company
Zone 3
29
Window
8.0 0.510 NFRC
0.34 NFRC
180 Existing
General Aluminum Company
Zone 3
30
Window
6.5 0.510 NFRC
0.34 NFRC
90 Removed
General Aluminum Company
Zone 3
31
Window
18.0 0.510 NFRC
0.34 NFRC
901 Removed
I General Aluminum Company
Zone 3
32
Window
3.5 0.510 NFRC
0.34 1 NFRC
901 Removed
I General Aluminum Company
Zone 3
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
Hat Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len H t Dist Len H t
17
Bug Screen
0.76
18
None
1.00
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Screen
0.76
26
_Bug
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
31
Bug Screen
0.76
32
1Bug, Screen
1 0.76
Ener
Pro 5.1 by Ener Soft User Number: 5732 RunCode: 2011-03-22711:49:05 ID: 1022511
Page 8 of 16
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
Mr. & Mrs. KEEGAN'S Residence
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family 2 Existing+ Addition/Alteration
Date
1312212011
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavitv Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Type Area
U -Factor SHGC2
Azm Status Glazing Type Location/Comments
33 Window 18.0
0.510 NFRC 0.34 NFRC 90 Removed General Aluminum Company Zone 3
34 Window 3.5
0.510 NFRC 0.34 NFRC 90 Removed General Aluminum Company Zone 3
35 Skylight 0.5
0.430 NFRC 0.30 NFRC 0 New Solatuhe Zone 3
36 Window 6.7
0.510 NFRC 0.34 NFRC 90 New General Aluminum Company Zone 3
37 Window 18.0
0.510 NFRC 0.34 NFRC 90 New General Aluminum Company Zone 3
38 Window 3.5
0. 5101 NFRC 0.34 NFRC 90 New General Aluminum Company Zone 3
39 Window 18.0
0.510 NFRC 0.34 1 NFRC 90 New General Aluminum Company Zone 3
40 Window 3.5
0.510 NFRC 0.34 NFRC 90 New General Aluminum Company Zone 3
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID Exterior Shade Type
Window
SHGC Hat Wd
Ove hang Left Fin Right Fin
Len H2L LExt RExt Dist Len H t Dist Len H t
33 Bug Screen
0.76
34 Bug Screen
0.76
35 None
1.00
36 Bug Screen
0.76
37 Bug Screen
0.76
38 Bug Screen
0.76
39 Bug Screen
0.76
40 Bug Screen
0.76
Ener Pro 5.1 by Ener Soft
User Number: 5732
RunCode: 2011-03-22711:49:05 ID: l 022511 Page 9 of 16
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R
Project Name
Mr. & Mrs. KEEGAN'S Residence
Building Type 12 Single Family ❑ Addition Alone
❑ Multi Family [0 Existing+ Addition/Alteration
Date
3/22/2011
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existing Altered Removed Volume Year Built
HVAC System - Zone 1 Zone 1
852
8,520 2003
HVAC System - Zone 2 Zone 2
1,532
18,384 2000
HVAC System - Zone 3 Zone 3
1,585
15,850 2000
Addition
315
3,150
Totals 315 3,969 0 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC System - Zone 1 1 Central Furnace
78% AFUE Split Air Conditioner 9.7 SEER Setback
Existing
HVAC System - Zone 2 1 Central Furnace
78% AFUE Split Air Conditioner 9.7 SEER Setback
Existing
HVAC System - Zone 3 1 Central Furnace
78% AFUE Split Air Conditioner 9.7 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
HVAC System - Zone 1 Ducted Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
HVAC System - Zone 2 Ducted Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
HVAC System - Zone 3 Ducted Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
A O Smith Water Products
1
Large Gas
Kitchen Pipe Ins
80,000
74
0.78
0.00%
0.0
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
_ o
Ca
—
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qt . HP
Plenum Outside Buried
11
Energ Pro 5.1 by Energ Soft User Number: 5732
RunCode: 2011-03-22T11:49:05 ID: 1 022511
Pae 10 of 16
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Mr. & Mrs. KEEGAN's Residence
Date
3/22/2011
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent LI -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or facto -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
S ace Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
4150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2011-03-22711:49:05 ID: Ig022511 Page 11 of 16
MANDATORY MEASURES SUMMARY: Residential (Page. 2 of 3 MF -1 R
Project Name
Date
Mr. & Mrs. KEEGAN's Residence
1312212011
§150(m)l : All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m i 0: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2011-03-22T11:49:05 /D: lg022511 Page 12 of 16
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Mr. & Mrs. KEEGAN's Residence
13/22/2011
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with 150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number: 5732 Run Code: 2011-03-22T11:49:05 /D: lg022511 Page 13 of 16
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Mr. & Mrs. KEEGAN's Residence
Date
3/22/2011
System Name
HVAC System - Zone 1
Floor Area
852
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING
CFM Sensible
Total Room Loads 491 10,972
Return Vented Lighting 0
Return Air Ducts 930
Return Fan 0
Ventilation 0 0
Supply Fan 0
Supply Air Ducts 930
TOTAL SYSTEM LOAD 1 12,833
PEAK
COIL HTG.
PEAK
Heating System
Latent
CFM
Sensible
Output per System 0
1,002
227
8,135
Total Output (Btuh) 0
Output (Btuh/s ft) 0.0
578
Cooling System
0
Output per System 1
0 0
0
Total Output (Btuh) 1
1,002
0
Total Output (Tons) 0.0
578
Total Output (Btuh/sqft) 0.0
Total Output s ft/Ton 10,224,000.0
9,290
Air System
CFM per System
0
HVAC EQUIPMENT SELECTION
Airflow cfm
0
Default FAU/AC 1992 - 2005 1
0
0
Airflow (cfm/s ft)
0.00
Airflow cfm/Ton
0.0
Outside Air (%)
0.0%
Total Adjusted System Output 1
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
1 0
Aug 3 PM
1 0
Jan 1 AM
Outside Air (cfm/s ft) 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak)
26 OF
Outside Air
0 cfm
69 OF
69 OF 105 OF
—
Heating Coil
104 OF
ROOM,y
70 OF
COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak)
1.12/78°F
Outside Air
0 cfm
80! 64 °F
80/64°F 55/54°F
0.
c
Cooling Coil 57 / 54 OF
43.5 % ROOM
78 / 63 OF
EnergyPro 5.1 by EnergySoft
User Number., 5732 RunCode: 2011-03-22T11:49:05 ID: lg022511 Page 14 of 16
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Mr. & Mrs. KEEGAN'S Residence
Date
3/22/2011
System Name
HVAC System - Zone 2
Floor Area
1,532
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING
CFM Sensible
Total Room Loads 1,026 22,924
Return Vented Lighting 0
Return Air Ducts 1,944
Return Fan 0
Ventilation 0 0
Supply Fan 0
Supply Air Ducts 1,944
TOTAL SYSTEM LOAD 1 26,811
PEAK
COIL HTG.
PEAK
Heating System
Latent
CFM
Sensible
Output per System
0
1,082
465
16,604
Total Output (Btuh)
0
Output Btuh/s ft
0.0
1,180
Cooling System
0
Output per System 1
0 0
0
Total Output (Btuh) 1
11082
0
Total Output (Tons) 0.0
1,180
Total Output (Btuh/sqft) 0.0
Total Output s ft/Ton 18,384,000.0
18,964
Air System
CFM per System
0
HVAC EQUIPMENT SELECTION
Airflow cfm
0
Default FAU/AC 1992 - 2005 1
0
0
Airflow cfm/s ft)
0.00
Airflow (cfm/Ton)
0.0
Outside Air (%)
0.0%
Total Adjusted System Output 1
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0
Aug 3 PM
0
Jan 1 AM
Outside Air (cfm/s ft) 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak)
26 OF
Outside Air Ar
0 cfm
69 OF
69 OF 105 OF
--
Heating Coil
104 OF
ROOM J1
70 OF
COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak)
112/78°F
Outside Air Ar
0 cfm
80 / 63 OF
80/63°F 55/54°F
Cooling Coil 57 / 54 OF
42.4% ROOM
78 / 63 OF
EnergyPro 5.1 by EnergySoft
User Number: 5732 RunCode: 2011-03-22T11:49:05 /D: lg022511 Page 15 of 16
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Mr. & Mrs. KEEGAN's Residence
Date
3/22/2011
System Name
HVAC System - Zone 3
Floor Area
1,900
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,068
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output perSystem 0
23,872
2,142
786
27,641
Total Output (Btuh) 0
0
Output Btuh/s ft 0.0
2,024
1,964
Cooling System
01
0
Output per System
1
0
0 0
0
Total Output (Btuh)
1
0
2,142
0
Total Output (Tons)
0.0
2,024
1,964
Total Output (Btuh/s ft)
0.0
Total Output s ft/Ton
22,800,000.0
1 27,920
31,568
Air System
CFM perSystem
0
HVAC EOUIPMENT SELECTION
Airflow cfm
0
Default FAU/AC 1992 - 2005 1
0
0
Airflow (cfm/sgft)
0.00
Airflow (cfm/Ton)
0.0
Outside Air (%)
0.0%
Total Adjusted System Output 1
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0
Aug 3 PM
0
Jan 1 AM
Outside Air (cfm/s ft)
0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
26 OF
Outside Air
0 cfm
68 OF
68 OF 105 OF
--
Heating Coil
103 OF
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak)
112/78°F
Outside Air
0 cfm
80 / 64 OF
80/64°F 55/54°F
Cooling Coil 57 / 54 OF
43.4% ROOM
78 163 OF
E I 1 1 4 1
EnergyPro 5.1 by EnergySoft
User Number: 5732 RunCode: 2011-03-22711:49:05 1D: lg022511 Page 16 of 16
M
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Mr. & Mrs. KEEGAN'S Residence
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family 0 Existing+ Addition/Alteration
Date
1312212011
Project Address
50805 El Dorado Dr. La Quinta
California Energy Climate ZoneTotal
CA Climate Zone 15
Cond. Floor Area
4, 284
Addition
315
# of Stories
1 1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity ( Features (see Part 2 of 5)
Status
Slab Unheated Slab -on -Grade
None 3,190 Perim = 0'
Existing
Wall Wood Framed
R-19 2,154
E�iking
Roof Wood Framed Attic
R-30 3,953 0sting
Door Opaque Door
None 28
lExisting
Slab Unheated Slab -on -Grade
None 579 Perim = 0'
New
Wall Wood Framed
R-21 3,395 V
New
Door Opaque Door
None 24
New
Roof Wood Framed Attic
R-38 315 Radiant Barrier
New
FENESTRATION U- Exterior
Orientation Area(ft`) Factor SHGC Overhang Sidefins Shades
Status
Right (N) 144.0 0.510
0.34 none nAe Bug Screen
Existing
Rear (W) 357.2 0.510
0.34 none none Bug Screen
Existing
Front (E) 92.3 0.510
0.34 none none Bug Screen
Existing
Skylight 16.0 0.550
0.67 jjqk None 4.1 tip F�F
Existing
Right (N) 36.0 0.510
0.34 - , none n
Left (S) 32.0 0.510
0. 47 no& non UI I jupgeh-mgEing
Skylight 0.5 0.430
AQ,,30 none non �PG & S
Front (E) 49.7 0.5100.34
noenon
F OR GUNS I HUCTI
HVAC SYSTEMS
Qty. HeatingMin. Eff
DA BY
Coolin 1, Eff --- Thermostat
Status
1 Central Furnace 78°l AFUE
Split Air Conditioner 9.7 SEER Setback
Existing
1 Central Furnace\\--- -- 1._\T8% AFUE
Split Air Conditioner 9.7 SEER Setback
Existing
1 Centrak) i*ace '\ 78% AFUE
Split Air Conditioner 9.7 SEER Setback
Existing
HVAC DISTRI160TIONX
Location Heating
Duct
Cooling Duct Location R -Value
Status
HVAC System -70717117-777 Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
HVAC System - Zone 2 Ducted
Ducted
4.2
Existing
HVAC System - Zone 3 Ducted
D
cte C "' I
4.2
Existing
WATER HEATING
Qt . T e Gallons
BUILDING & SAFETY DEPT.
Min.
Status
F R
MAR 2 3 2011
rE—nergyPro 5.1 by EnergySoft User Number: 5732
DATE BY I
RunCode: 2011-03-22711:49:05 ID: 1022511
Pae 1 of 8
BY:
Reg: 2 -N 01985 A- 0000000-0000
Registration Date/Time: 2011/03/22 15:42:03 HERS Provider: Ca10ERTS, Inc
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Mr. & Mrs. KEEGAN'S Residence.
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
I Date
3/22/2011
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The DHW System A O Smith Water Products FPSH-75 is a non-NAECA large storage gas water heater. Verify DHW details.
The Existing Water Heater A O Smith Water Products FPSH-75 has an EF less than the Vintage Defaults. Field verification is required.
The Existing Furnace Default FAU/AC 1992 - 2005 has an AFUE less than the Vintage Defaults. Field verification is required.
The Existing Air Conditioner Default FAU/AC 1992 - 2005 has an SEER less than the Vintage Defaults. Field verificationlds required.
HIGH MASS Design - Verify Thermal Mass: 227.0 ft' Covered Slab Floor, 3.500" thick at Zone 1
HIGH MASS Design - Verify Thermal Mass: 625.0 ft' Exposed Slab Floor, 3.500" thick at Zone i
The Existing Furnace Default FAU/AC 1992 - 2005 has an AFUE less than the Vintage Defaults. Field v rification is;rdquired.v
The Existing Air Conditioner Default FAU/AC 1992 - 2005 has an SEER less than the Vintage Det�Ofts. Field verifica�t,'VIs required.
HIGH MASS Design - Verify Thermal Mass: 1,532.0 ft' Covered Slab Floor, 3.500" thick at Zone 2
The Existing Furnace Default FAU/AC 1992 - 2005 has an AFUE less than the Vintage �Defaults. Field verification is required.
The Existing Air Conditioner Default FAU/AC 1992 - 2005 has an SEER less than the Vi' tage Defaulttsl Field verification is required.
40
HIGH MASS Design - Verify Thermal Mass: 227.0 ft' Covered Slab Floor, 3!500" thick at Zon
HIGH MASS Design - Verify Thermal Mass: 579.0 ft' Exposed Slab F oor, 3.500 7, i k at Zone 3
HERS REQUIRED VERIFICATION �
Items in this section require field testing and/or Venftapon'by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measurers listed,,belov,+r,for final to be given.
tr 'N
Ener Pro 5.1 by EnergySoft User Number.' 5732 RunCode: 2011-03-22711:49:05 ID: 1022511 Pa e 2 of 8
Reg: 211-N0014856A-000000000-0000 Registration Date/Time: 2011/03/22 15:42:03 HERS Provider: Ca10ERTS, Inc
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Mr. & Mrs. KEEGAN'S Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
3/22/2011
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HIGH MASS Design - Verify Thermal Mass: 579.0 ft' Exposed Slab Floor, 4.000" thick at Addition
The Roof R-38 Roof Attic w/Radiant Barrier includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as
specified in Residential Appendix RA4.2.2.
Ado
�t
HERS REQUIRED VERIFICATIOe�
Items in this section require field testing and/or veKrW'qaJiM-by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measAs listed"'Wow,for final to be given.
041t 1� r
3-1
Energ yPT 5.1 by Ener Soft User Number.' 5732 RunCode: 2011-03-22T11:49:05 ID: l 022511 Pa e 3 of 8
Reg: 211-N0014856A-000000000-0000 Registration Date/Time: 2011/03/22 15:42:03 HERS Provider: Ca10ERTS, Inc
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R
Project Name
Building Type 10 Single Family ❑ Addition Alone
Date
Mr. & Mrs. KEEGAN'S Residence
0 Multi Family 0 Existing+ Addition/Alteration
1312212011
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 8.29 8.56 -0.27
Space Cooling 125.46 121.07 4.39
Fans 25.75 24.93 0.83
Domestic Hot Water 5.98 5.98 0.00
Pumps 0.00 0.00 0.00
Totals 165.48 160.53 4.95
Percent Better Than Standard: 3.0%
BUILDING COMPLIES - NO HERS VERIFICATION REM IRED>
`t eriestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof V�Ia1f�Area Area
+
Number of Dwelling Units: 1.00 (E)81, 142
Fuel Available at Site: Natural Gas (S) 1,047 32
Raised Floor Area: 0 (w) 786 357
Slab on Grade Area: 3,769 (N) 3668 180
Average Ceiling Height: 10.7 Roof 4,284 17
Fenestration Average U-Factor: 0.51 TOTAL: 728
Average SHGC: 0.34 Fenestration/CFA Ratio: 17.0%
REMARKS #1
r
STATEMENT OF COMPLIANCE
This certificate of compliance lists the builditig features and specifications needed
to comply with Title 24, Parts 1 therAdministrative Regulations and Part 6 the
Efficiency Standards of the Cal�rnia ode of Rea gulations.
The documentation autl�o?here y certifiesthat the documentation is accurate and complete.
40
Documentation Auth
Santia o Lopez=O
Company %MPO
3/22/2011
P.O. ox 1018 Santiago Lo ez-Ocam o
Address v � Name g p p
Cit /State/Zi fla Quinfa, Ca 92247 Phone 760.485.8927 Signed Date
Y
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction", ocuu ents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company GLS Architecture Group
Address 74991 Joni Dr. # 9 Name
City/State/Zip Palm Desert Ca 92211 Phone 760.340.3528 Signed License # Date
EnerqvPro 5.1 by EnerqvSoft User Number: 5732 RunCode: 2011-03-22711:49:05 ID: 10022511 Page 4 of 8
Reg: 211-N0014856A-000000000-0000 Registration Date/Time: 2011/03/22 15:42:03 HERS Provider: Ca10ERTS, Inc
CERTIFICATE OF COMPLIANCE: Residential
(Part 4 of 5) CF -1 R
Project Name
Mr. & Mrs. KEEGAN's Residence
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family G3 Existing+ Addition/Alteration
Date
1312212011
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
I Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Slab
227
0.730 None
0
180 Existing 4.4.7-A1
Zone 1
Slab
6250-730
None
0
180 Existing 4.4.7-A 1
Zone 1
Wall
167
0.074 R-19
0
90 Existing 4.3.1-A5
Zone 1
Wall
52
0.074 R-19
270
90 Existing 4.3.1-A5
Zone 1
Wall
93
0.074 R-19
180
90 Existing 4.3.1-A5
Zone 1
Wall
197
0.074 R-19
90
90 Existing 4.3.1-A5
Zone i
Roof
852
0.031 R-30
0
0 Existing 4.2.1-A20
Zone 1
Slab
1,532
0.730 None
0
180 Existing 4.4.7-A1
4 Zone 2
Wall
219
0.074 R-19
270
90 Existing 4.3.1-A5
/r' Zone 2
Wall
108
0.074 R-19
0
90 Existing 4.3.1-A5
Zone 2
Wall
94
0.074 R-19
180
90 Existing 4.3.1-A5
Zonel�, "OK
Wall
84
0.074 R-19
90
90 Existing 4.3.1-A5
Zone 2'V"
Door
281
0.500 one
90
90 1 Existing 4.5.1-A4
Zone t2
Roof
1,516
0.031 R-30
0
0 Existing 4.2.1-A20 ,,% Zone 2
Slab
227
0.730 None
0
180 Existing 44j7 -A1
Zone 3
Slab
579
0.730 None
0
180 Existin 4,4.7-A i
Zone 3
FENESTRATION SURFACE DETAILS
` ,
ID
Type
Area LI -Factor'
SHGCz
Azm Status
w Glazing T" ,►
Location/Comments
1
Window
24.0 0.510 NFRC
0.34 NFRC 0 Existing
Genew"rafAluminum Company
Zone 1
2
Window
24.0 0.510 NFRC
0.34 NFRC 0 Existing
,General Aluminum Company
Zone 1
3
Window
48.0 0.510 NFRC
0.34 NFRC 270 Existing
'General Aluminum Company
Zone 1
4
Window
36.0 0.510 NFRC
0.34 NFRC 90 Existing
'General Aluminum Company
Zone 1
5
Window
36.0 0.510 NFRC
0.34 NFRC 270 Existing
Genera/ Aluminum Company
Zone 2
6
Window
8.0 0.510 NFRC
0.34 NFRC 270 E)ksting
Genera Aluminum Company
Zone 2
7
Window
36.0 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
Zone 2
8
Window
8.0 0.510 NFRC
0.34 NFRC ,,270 Existing General Aluminum Company
Zone 2
9
Window
64.0 0.510 NFRC
0.34 NFRC 2'70 Existing
General Aluminum Company •
Zone 2.
10
Window
10.6 0.510 NFRC
0.34 NFRC *,,270 Existing
General Aluminum Company
Zone 2
11
Window
64.0 0.510 NFRC
0.34 NFt C'`, 230 Existing
General Aluminum Company
Zone 2
12
Window
10.6 0.510 NFRC
0.34 ,NFRC 270 Existing
General Aluminum Company
Zone 2
13
Window
48.0 0.510 NFRC
0.3W NFRC '9%, 0 `Existing
General Aluminum Company
Zone 2
14
Window
9.3 0.510 NFRC
X0:34 ,NFRC , 90 Existing
General Aluminum Company
Zone 2
15
Window
9.3 0.510 NFRC
'w 'M34 NFRC 90 Existing
General Aluminum Company
Zone 2
16
Window
13.7 0.510 NFRC
0.34,; NFRC 90 Existing
General Aluminum Company
Zone 2
(1) Ll -Factor Type: 116-A = DefauftsTable from;Standards, NFRC = Labeled Value
2 SHGC Type: 116-B =;Default Table fromStandards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
A y
ID
�►
Exterior Shade T e `�SHGC_
Window
.__.H "t` I Wd
Ove hang Left Fin Right Fin
Len I HqA LExt RExt Dist Len H t Dist Len H t
1
Bug Screen
^, `� 0.76
2
Bug Screen
- 0.76
3
Bug Screen4
^-'0.76
4
Bug Screen
0.76
5
Bug Screen
r 0.76
6
Bug{Screen
!Z 0.76
7
Bug Screen,
0.76
8
Bug Screen` 4 ,,,,,,,00iK 0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
JBug Screen
0.76
16
IBug Screen
0.76
EnergyPro
5.1 by EnergySoft User Number: 5732
RunCode: 2011-03-22711:49:05 ID: l 022511
Page 5 of 8
Reg: 211-N0014856A-000000000-0000 Registration Date/Time: 2011/03/22 15:42:03 HERS Provider: Ca10ERTS, Inc
CERTIFICATE OF COMPLIANCE: Residential
(Part 4 of 5) CF -1 R
Project Name
Mr. & Mrs. KEEGAN'S Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family 10 Existing+ Addition/Alteration
Date
3/22/2011
-OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Wall
1331
0.074 R-19
0
90 Existing 4.3.1-A5
Zone 3
Wall
1581
0.074 R-19
270
90 Existing 4.3.1-A5
Zone 3
Wall
640
0.074 R-19
180
90 Existing 4.3.1-A5
Zone 3
Wall
210
0.074 R-19
90
90 Existing 4.3.1-A5
Zone 3
Roof
1,585
0.031 R-30
0
0 Existing 4.2.1-A20
Zone 3
Slab
579
0.730 None
0
180 New 4.4.7-A1
Zone 3
Wall
3,056
0.069 R-21
0
90 New 4.3.1-A6
Zone 3
Door
24
0.500 None
0
90 New 4.5.1-A4
Zone 3
Wall
188
0.069 R-21
180
90 New 14.3.1-A6
Zone 3
Wall
150
0.069 R-21
90
90 New 4.3.1-A6
Zone 3
Roof
315
0.025 R-38
0
0 New 4.2.1-A21
Zone 3
FENESTRATION SURFACE DETAILS
ID
Type
Area LI -Factor'
SHGCz
Azm Status
s. Glazing TY /!
Location/Comments
17
Window
24.0 0.510 NFRC
0.34 NFRC
90 Existing
Gral,Aluminum Corrjpany
Zone 2
18
Skylight
16.0 0.550 Default
0.67 Default
0 Existing
"Double Non Metal Clear
Zone 2
19
Window
48.0 0.510 NFRC
0.34 NFRC
0 Existing
General Aluminum Company
Zone 3
20
Window
12.5 0.510 NFRC
0.34 NFRC
0 New,Ggnerel
A/umirium Company
Zone 3
21
Window
12.5 0.510 NFRC
0.34 NFRC
0 N#w
Gege5l Aluminum Company
Zone 3
22
Window
11.0 0.510 NFRC
0.34 NFRC
0, `IN61w
Gener-a-FAluminum Company
Zone 3
23
Window
36.0 0.510 NFRC
0.34 NFRC
270 Existi'gg
General Aluminum Company
Zone 3
24
Window
36.0 '0.510 NFRC
0.34 NFRC270
Existin General Aluminum Company
Zone 3
25
Window
2.3 0.510 NFRC
0.34 NFRC
180 Existing ' General Aluminum Company
Zone 3
26
Window
2.3 0.510 NFRC .
` 0.34 NFR
0,,180 Existing
General Aluminum Company
Zone 3
27
Window
2.3 0.510 NFRC
0.34 NFP
t,$0 Existing
General Aluminum Company
Zone 3
28
Window
17.1 0.510 NFRC
0.34 SRC
NX 180 Existing
General Aluminum Company
Zone 3
29
Window
8.0 0.510 NFRC
0,3,W NFRC
X1`80 "Existing
General Aluminum Company
Zone 3
30
Window
6.5 0.510 NFRC
10.'34;NFRC
%90 Removed
General Aluminum Company
, Zone 3
31
Window
18.0 0.510 NFRC
lw'0:,34 NF13C
90 Removed
General Aluminum Company
, Zone 3
32
Window
3.5 0.510 NFRC
1 0.34, 'NFRC
90 Removed
General Aluminum Company
`� Zone 3
(1) LI -Factor Type: 116-A = Default Table from'Stand'ards, NFRC = Labeled Value
2 SHGC Type: 116-B =Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
- V, -
ID
Exterior Shade T e ,%,SHGC-..._H
Window
"t` I Wd
Overhanq Left Fin
Len H t LExt RExt Dist Len
Ri ht Fin
H t Dist Len H t
17
Bug Screen
Nk, 0.76
--
-
18
None""
1 00
19
Bug Screenm
`"0.76
20
Bug Screen
"� ,� 0.76
21
Bug S,cAen
, -0.75
22
Bu �86reen
0.76
23
Bug Screed
a 76
24
Bug Screen,*%� 0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
31
Bug Screen
0.76
32
Bug Screen
0.76
EnergyPro
5.1 by EnergySoft User Number 5732 RunCode: 2011-03-22711:49:05 ID: 1022511
Pa e 6 of 8
Reg: 211-N0014856A-000000000-0000 Registration Date/Time: 2011/03/22 15:42:03 HERS Provider: Ca10ERTS, inc
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
Mr. & Mrs. KEEGAN's Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family 2 Existing+ Addition/Alteration
Date
3/2 212 0 1 1
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
r
11 X
FENESTRATION SURFACE DETAILS
ID Type I Area LI -Factor' SHGCz
Azm Status Glazing e Location/Comments
33 Window 18.0 0.510 NFRC 0.34 NFRC 90 Removed G65;'raIJAluminum Company Zone 3
34 Window 3.5 0.510 NFRC 0.34 NFRC 90 Removed `General Aluminum Company Zone 3
35 Skylight 0.5 0.430 NFRC 0.30 NFRC 0 New solatube A Zone 3
36 Window 6.7 0.510 NFRC 0.34 NFRC 90 New, 'general Aluminum Company Zone 3
37 Window 18.0 0.510 NFRC 0.34 NFRC 90 Now G igeral Aluminum Company Zone 3
38 Window 3.5 0.510 NFRC 0.34 NFRC 90 =New GeneraTAluminurn Company Zone 3
39 Window 18.0 0.510 NFRC 0.34 NFRC 9'0 Ne General Aluminum Company Zone 3
40 Window 3.5 0.510 NFRC 0.34 NFRC 90 New General Aluminum Company Zone 3
s
(1) Ll -Factor Type: 116-A = Default Table from�StV`dards, NFRC = Labeled Value
2 SHGC Type: %116-B =°Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS N\
� Window
ID Exterior Shade Ty e SHGC,.__H `t' Wd
Overhang Left Fin Right in
Len H t LExt RExt Dist Len H t Dist Len H t
33 Bug Screen ^- 0.76
34 Bug Screen �`.,�0.76
35 None
36 Bug Screen' °*0,, 0.76
37 Bug S,cjeen f % 0.76
38 Bug�Screen 0.76
39 Bug Scr66n, 0.76
40 Bug Screen 0.76
Ener Pro 5.1 by EnergySoft User Number: 5732
RunCode: 2011-03-22711:49:05 ID: 1 022511 Page 7 of 8
Reg: 211-N0014856A-000000000-0000 Registration Date/Time: 2011/03/22 15:42:03 HERS Provider: Ca10ERTS, Inc
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R
Project Name
Mr. & Mrs. KEEGAN'S Residence
Building Type G3 Single Family ❑ Addition Alone
❑ Multi Family 10 Existing+ Addition/Alteration
Date
1312212011
BUILDING ZONE INFORMATION
Floor Area
System Name Zone Name New Existing Altered Removed Volume Year Built
HVAC System - Zone 1 Zone 1 852
8,520 2003
HVAC System - Zone 2 Zone 2 1,532
18,384 2000
HVAC System - Zone 3 Zone 3 1,585
15,850 2000
Addition 315
3,150
. 4
r�
Totals 3151 3,969 0
HVAC SYSTEMS OZ= -4
System Name Ot . Heating Type Min. Eff. CoolindyType Min. Eif' Thermostat Type Status
HVAC System - Zone 1 1 Central Furnace 78% AFUE Split Air Con`�itioner 9: SEER Setback
Existing
HVAC System - Zone 2 1 Central Furnace 78% AFUE Split. , it Conditioner 9'7 SEER Setback
Existing
HVAC System - Zone 3 1 Central Furnace 78% AFUE SpJ Air Conditioner --m-0,19.7 SEER Setback
Existing
HVAC DISTRIBUTION *,
Duct
System Name Heating Cool n Duct Location R -Value
Ducts
Tested? Status
HVAC System - Zone 1 Ducted Ducted '+*,I; Attic, Ceiling Ins, vented 4.2
❑ Existing
HVAC System - Zone 2 Ducted Ducted t' Attic, Ceiling Ins, vented 4.2
❑ Existing
HVAC System - Zone 3 Ducted Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
❑
WATER HEATING SYSTEM$t
S stem Name
�Q ' �:
�., T e
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
A O Smith Water Products
�1,
Laige'6as
Kitchen Pipe Ins
80,000
74
0.78
0.00%
0.0
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Y
Hot Water Piping Length
ft
2
0
C6
v N
a
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty. HP
Plenum Outside
Buried
EnergyPro 5.1 by Ener Soft User Number.' 5732 RunCode: 2011-03-22711:49:05 ID: 1q022511
Page 8 of 8
Reg: 211-N0014856A-000000000-0000 Registration Date/Time: 2011/03/22 15:42:03 HERS Provider: Cd10ERTS, Inc