12-0015 (AR)P.O.,BOX 1504
` 78495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Applicatiori�Number: 12 -.0000001'5
Property Address:
5-078-65 Eli DORADO DR
APN:
777 -290 -017 -
Application description:
ADDITION - RESIDENTIAL
Property Zoning:
LOW DENSITY RESIDENTIAL
Application valuation:
30000
Applicant:
r
T4ht 4 4 Q"
Architect or Engineer:
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, nd my License is in full force and effect.
License Class: B kens 80 -0.21
Date: /\�ntractor:
OWNER-BUI ER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not'apply to an owner of
property who builds or. improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.). '
( ) I am exempt under Sec. , BAP.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
Owner:
CAMARELLA FAMILY TRUST
50865 EL DORADO DR
IF
LA QUINTA, CA 922511j
Contractor:
WHITLEY'S CONSTR
7.7775 JACKAL DRI
PALM DESERT, CA
(760)341-9480
Lic. No.: 805021
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 2/10/12
20 KI UD
O.RPRT-Nn--.---_ , i
IkYfiF?.AQ,UINeA
A; y�
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier GRANITE STATE Policy Number 007200169
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to th��iiworkers' compensation provisions of Section
3 00 o�f the Labor Code, I shall for fi>'ith c i(y with those provisions.
'Sale :,,43
(� Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSA 0 COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant; each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission, related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. 1 agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby auth rize representatives
of this cou ty t enter upon the above-mentioned property for inspection
/purpo �.
e: ignature (Applicant or Agent): �� i
r
Application Number . . . . . 12-00000015
Structure Information
Construction Type . .
. . . TYPE V, UNPROTECTED
Occupancy Type
. . . DWELLG/LODGING/CONG <=10
Other struct info . .
. . . CODE EDITION 2010
# BEDROOMS
1.00
FIRE SPRINKLERS NO
FLOOD ZONE NO
--7 -------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
340.00
Permit . . . . .
BUILDING PERMIT
Additional desc .
Permit Fee
284..50 Plan Check Fee
184.93
Issue Date . . . .
Valuation
30000
Expiration Date
8/08/12
Qty Unit Charge
Per
Extension
BASE FEE
252.00
5.00 6.5000
----------------------------------------------------------------------------
THOU BLDG 25,001-50,000
32.50
Permit
ELECT - ADD/ALT/REM
Additional desc .
Permit Fee . . . .
-26.90 Plan Check Fee'.
6.73
Issue Date . . .
Valuation
0
Expiration Date
8/08/12
Qty Unit Charge.
Per
Extension
BASE FEE
15.00
340.00 .0350
----------------------------------------------------------------------------
ELEC NEW RES - 1 OR 2 FAMILY
11.90
Permit . . .
MECHANICAL
Additional desc .
Permit Fee
37.00 Plan Check Fee
9.25
Issue Date . . . .
Valuation . . . .
0
Expiration Date
8/08/12
Qty Unit Charge
Per
Extension
BASE FEE
15.00
2.00 4.5000
EA MECH VENT INST/ DUCT ALT
9.00
2.00 6.5000
-----------------------------------------------------
EA MECH VENT FAN
-----------------------
13.00
Permit . . .
PLUMBING
Additional desc .
Permit Fee
39.00 Plan Check Fee
9.75
LQPERAI[T
Application Number . . . . . 12-00000015
Permit . . . . . . PLUMBING
Issue Date . . . . Valuation . . . .
0
Expiration Date 8/08/12
Qty Unit Charge 'Per
Extension
BASE FEE
15.00
3.00 6.0000 EA PLB FIXTURE
18.00
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
1.00 3.0000 EA PLB FIXTURE DRAIN/VENT REP/ALT
3.00
----------------------------------------------------------------------------
Special Notes and Comments
315 SF BEDROOM & BATH ADDITION TO EXIST.
SFD Q FRONT YARD. ARCHITECT: CHARLES
GARLAND C11991. 2010 CODES.MINOR
ADJUSTMENT 2012-640 FOR 18 FOOT FRONT
SETBACK.
----------------------------------------------------------------------------
Other Fees . . . . . . . BLDG STDS.ADMIN (SB1473)
2.00
ENERGY REVIEW FEE
18.49
STRONG MOTION (SMI) -"RES
3.00
Fee summary Charged Paid Credited
--
Due
----------------- ---------- -------- --------------------
Permit Fee Total 387.40 .00 • .00
387:40
Plan Check Total 210.66 .00 .00
210.66
Other Fee Total 23.49 .00 .00
23.49
Grand Total 621.55 .00 .00
621.55
LQPERAI IT
. Bin #'.
Permit #
Pcojeet Address:
A. P: Number:
Legal Description:
contractor. 4,�Wi me
Address: z7 T s
City, ST, Zip:A9
PAr:ch.,Eng,r.,
,3�0� 4a tsigner:
Address:
City, ST, Zip:
City of La Quinta
Building 8t Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Owner's Name:
Address:.
c City. ST, Zip: G Q (VU CC- .
w �uti wi
P-mjed Description:
City Lie. #;
El
^- -5'-3
2,*12
Telephone: He
Constrvdion Type: Occupancy:
.TState Lic. #: .u:'>-: ' Project type (circle one): New Add'n Alter Repair Demo
Name of Contact Person: � �, . ' / e Sq. Ft : ,30 #Stories: #Units:
Telephone # of Contact Person: Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS UNE
#
Submittal
Req'd
Rec'd
TRACMG PERMIT FEES
Plan Sets
3
Plan Check submitted ' �/ Item Amount
Structural Cal-
Reviewed, ready for erections Plan Cheek Deposit
Truss Calcs.
• O 1
Z
Called Contact Person GAOPlan Check Balance.
Title 24 Calcs.
Pians picked up 13� Construction
Flood plain plan
Plans resubmitted S Mechanical
Grading plan
2'! Review, ready for correctioe Electrical
n rssrr
Subcontoctor List
Called Contact Person �y Plumbing
Grant Deed
Plans picked up t) I.
H,0•A. Approval
Plans resubmitted Grading
IN HOUSE:-
'`' Review, ready for corrections/rssue Developer Impact Fee
Planning Approval
Called Contact Person A.I.P.P.
Pub. Wks. Appr
Date of permit issue
r—tSchool
Feta
Total Permit Fees I 4!J' i �
i/ate r r fa pica toss . em P
f
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVELONEAMOUNT:
LEVELTWOAMOUNT:
MITIGATION AMOUNT:
COMMAND. AMOUNT:
DATE:
RECEIPT:
CHECK#:
INITIALS:
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: iM_ ountain View Date: February 10, 2012
Owner's Name: Kenneth & Nancy Camarella Phone No.
Project Address: 50-865 El Dorado, LaQuinta, CA 02253
Project Description: Bedroom & Bath addition to Existing SFD
APN: 777-290-017 Tract #: Lot #'s:
XX1
Type of Development: Residential Commercial Industrial
Total Square Feet of Building Area: 315 sq. ft.
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer.
Dated: February 10, 2012 Signature: tvl�lr— Ld/
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Project Agreement Existing Not Subject to Fee
17620 65995 Approval Prior to 1/1/87 Requirement
Note:
Number of Sq.Ft. 315 sq. ft.
Amount per Sq.Ft. $ 0.00
Amount Collected $ 0.00
Building Permit Application Completed: Yes/No
By: Darryl S. Adams, Superintendent
Certificate issued by: Laurie Howard, Secretary HI Signature: �� a– D
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
MV:c/mydoes/deviecs.cel1ificate ofcompliance firm table. -TO USE.doc 1/16/03 T
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
CAMARRELLA's Residence
50865 EI Dorado Dr.
La Quinta, Ca 92253
Project Designer:
GLS Architecture Group
74991 Joni Dr. # 9
Palm Desert, Ca 92211
760.340.3528 It
6
CITY OF LA QUINTA
Report Prepared by: BUILDING & SAFETY DEPT.
APPROVED
Armando Chavez FOR CONSTRUCTION
GLS Architecture Group
74491 Joni Dr. suite # 9 DAT n ��ZBY
Palm Desert, Ca 92260
760 340.35.28
RECEIVED
JAN 0 6 2012
BY:
Job Number:
2011 -GLS -025
Date:
12/28/2011
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
Energ Pro 5. 1 by Ener Soft User Number: 5553 RunCode:2011-12-28712:02:41 ID: 201 1 -GLS -025
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance,
Form MF -1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
EnergyPro 5.1 by EnergySoft Job Number: ID: 2011 -GLS -025 User Number: 5553
1
2
3
10
13
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
CAMARRELLA's Residence
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration 11212812011
Date
Project Address
50865 El Dorado Dr. La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,284
Addition
315
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features see Part 2 of 5 Status
Slab Unheated Slab -on -Grade
None 3,969 Perim = 287' Existing
Wall Wood Framed
R-19 6,567 Existing
Roof Wood Framed Attic
R-30 3,953 Existing
Slab Unheated Slab -on -Grade
None 315 Perim = 58' New
Wall Wood Framed
R-21 1,369 New
Door Opaque Door
None 24 New
Roof Wood Framed Attic
R-38 315 New
FENESTRATION U-
Orientation Area(ft) Factor
Exterior
SHGC Overhang Sidefins Shades Status
Right (N) 121.0 0.510
0.34 none none Bug Screen Existing
Right (N) 20.0 0.400
0.35 none none Bug Screen New
Rear (lA9 357.4 0.510
0.34 none none Bug Screen
Existing
Left (S) 62.9 0.510
0.34 none none Bug Screen Existing
Left (S) 20.0 0.510
0.66 none none Bug Screen
Existing
Front (E) 92.3 0.510
0.34 none none Bug Screen
Existing
Skylight 0.5 0.430
0.30 none none None
New
Skylight 16.0 0.550
0.67 none none None
Existing
Left (S) 8.0 0.510
0.66 none none Bug Screen
New
Front (E) 52.7 0.400
0.35 none none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
2 Central Fumace 78% AFUE Split Air Conditioner 9.7 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
EXISTING Ducted
Ducted Attic, Roof Ins 4.2
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Energ Pro 5.1 by Energ Soft User Number: 5553 Run Code: 2011-12-28712:02:41 to: 2011 -GLS -025
Page 3 of 13
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
CAMARRELLA's Residence
Building Type ❑ Single Family ❑ Addition Alone
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
Date
11212812011
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures.listed below for final to be given.
Ener Pro 5.1 by EnergySoft User Number: 5553 RunCode: 2011-12-28T12:02:41 ID: 2011 -GLS -025 Page 4 of 13
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type ❑ Single Family ❑ Addition Alone
Date
CAMARRELLA's Residence
❑ Multi Family ❑ Existing+ Addition/Alteration
12/28/201
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/Wt r
Space Heating 10.52 9.02 1.50
Space Cooling 145.93 146.93 -1.00
Fans 25.64 25.68 -0.04
Domestic Hot Water 8.44 8.44 0.00
Pumps 0.00 0.00 0.00
Totals 190.53 190.08 0.45
Percent Better Than Standard: 0.2%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) . 1,778 145
Fuel Available at Site: Natural Gas (S) 2,570 91
Raised Floor Area: 0 (lM 1,778 357
Slab on Grade Area: 4,284 (N) 2,569 141
Average Ceiling Height: 10.0 Roof 4,284 17
Fenestration Average U -Factor: 0.50 TOTAL: 751
Average SHGC: 0.35 Fenestration/CFA Ratio: 17.5%
REMARKS,
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete
Documentation Author
Company. GLS Architecture Group
1228/2011
Address 74491 Joni Dr. suite # 9 Name Armando Chavez
Cit /State/Zi Palm Desert, Ca 92260 Phone 760 340.35.28 Sigrof Date
The individual with overall design responsibility hereby certifies tha e.proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealin verification of refrigerant charge, insulation installation quality, and building envelope seal'
installe s ' g and certification and field verification by an approved HERS rater.
D i er or Owner (per Business & Professions Code)
any GLS Architecture Group
Address 74991 Joni Dr. # 9 Name
City/State/Zip Palm Desert, Ca 92211 Phone 760.340.3528 Si License # Date
Ener Pro 5.1 by Ener Soft User Number. 5553 RunCode: 2011-12-28 712:02:41 ID: 2011 -GLS -025 Page 5 of 13
�—
• 4
00
CERTIFICATE OF COMPLIANCE: Residential
(Part 4 of 5) CF -1 R
Project Name
CAMARRELLA's Residence
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family 0 Existing+ Addition/Alteration
Date
12/28/2011
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Slab
3,969
0.730 None
0
180 Existing 4.4.7-A1
Wall
2,001
0.074 R-19
0
90 Existing 4.3.1-A5
Wall
1,421
0.074 R-19
270
90 Existing 4.3.1-A5
Wall
1,970
0.074 R-19
180
90 Existing 4.3.1-A5
Wall
1,176
0.074 R-19
90
90 Existing 4.3.1-A5
Roof
3,953
0.031 R-30
0
0 Existing 4.2.1-A20
Slab
315
0.730 None
0
180 New 4.4.7-A1
Wall
403
0.069 R-21
0
90 New 4.3.1-A6
Door
24
0.500 None
0
90 New 4.5.1-A4
Wall
509
0.069 R-21
180
90 New 4.3.1-A6
Wall
457
0.069 R-21
90
90 New 4.3.1-A6
Roof
315
0.025 R-38
0
0 New 4.2.1-A21
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC
Azm Status
Glazing Type Location/Comments
1
Window
12.5 0.510 NFRC
0.34 NFRC 0 Existing
General Aluminum Company
2
Window
12.5 0.510 NFRC
0.34 NFRC 0 Existing
General Aluminum Company
3
Window
24.0 0.510 NFRC
0.34 NFRC 0 Existing
General Aluminum Company
4
Window
24.0 0.510 NFRC
0.34 NFRC 0 Existing
General Aluminum Company
5
Window
48.0 0.510 NFRC
0.34 NFRC 0 Existing
General Aluminum Company
6
Window
20.0 0.400 NFRC
0.35 NFRC 0 New
U 0.401S 0.35 Z15
7
Window
48.0 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
8
Window
36.0 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
9
Window
8.0 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
10
Window
36.0 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
11
Window
8.0 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
12 Window
64.0 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
13
Window
10.7 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
14
Window
64.0 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
15
Window
10.7 0.510 NFRC
0.34 NFRC 270 Existing
General Aluminum Company
16
Window
36.01 0.510 NFRC
1 0.34 NFRC 270 Existing
General Aluminum Company
(1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len H t Dist '' Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11.
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
JBug Screen
0.76
Ener Pro 5.1 by EnergySoft User Number: 5553
RunCode: 2011-1248712:02:41 ID: 2011 -GLS -025 Page 6 of 13
CERTIFICATE OF COMPLIANCE:
Residential
(Part 4 of 5) CF -1 R
Project Name
CAMARRELLA's Residence
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
11212812011
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
U -Factor
SHGC2
Azm Status
Glazing Type Location/Comments
17
Window 36.0
0.510 NFRC
0.34 NFRC
270 Existing
General Aluminum Company
18
Window 2.3
0.510 NFRC
0.34 NFRC
180 Existing
General Aluminum Company
19
Window 2.3
0.510 NFRC
0.34 NFRC
180 Existing
General Aluminum Company
20
Window 2.3
0.510 NFRC
0.34 NFRC
180 Existing
General Aluminum Company
21
Window 20.0
0.510 NFRC
0.66 NFRC
180 Existing
Pittsburgh Coming GB 12x12
22
Window 8.0
0.510 NFRC
0.34 NFRC
180 Existing
General Aluminum Company
23
Window 48.0
0.510 NFRC
0.34 NFRC
180 Existing
General Aluminum Company
24
Window 9.3
0.510 NFRC
0.34 NFRC
90 Existing
General Aluminum Company
25
Window 9.3
0.510 NFRC
0.34 NFRC
90 Existing
General Aluminum Company
26
Window 24.0
0.510 NFRC
0.34 NFRC
90 Existing
General Aluminum Company
27
Window 13.7
0.510 NFRC
0.34 NFRC
90 Existing
General Aluminum Company
28
Window 36.0
0.510 NFRC
0.34 NFRC
90 Existing
General Aluminum Company
29
Skylight 0.5
0.430 NFRC
0.30 NFRC
0 New
Solatube
30
Skylight 16.01
0.550 Default
0.67 Default 0 Existing
Double Non Metal Clear
31
Window 8.01
0.510 NFRC
0.66 NFRC
180 New
Pittsburgh Corning GS 12x12
32
Window 6.71
0.400 1 NFRC
0.35 NFRC
90 New
U 0.401S 0.35 Z15
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
Hqt'l Wd
Ove hang Left Fin Right Fin
Len HqA LEA RExt Dist Len H t Dist Len H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
None
1.00
30
None
1.00
31
IBug Screen
0.76
32
JBug Screen
0.76
Ener Pro 5.1 by Ener Soft User Number: 5553 RunCode: 2011-12-28712:02.41 ID: 2011 -GLS -025 Pae 7 of 13
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
CAMARRELLA's Residence
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
12/28/2011
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments
33 Window 18.0 0.400 NFRC 0.35 NFRC 90 New U 0.40/S 0.35 Z15
34 Window 18.0 0.400 NFRC 0.35 NFRC 90 New U 0.40 / S 0.35 Z15
35 Window 5.0 0.400 NFRC 0.35 NFRC 90 New U 0.40 / S 0.35 Z15
36 Window 5.0 0.400 NFRC 0.35 NFRC 90 New U 0.401S 0.35 Z15
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window Ove hang Left Fin Right Fin
ID Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len H t Dist Len H t
33 Bug Screen 0.76
34 Bug Screen 0.76
35 Bug Screen 0.76
36 Bug Screen 0.76
Ener Pro 5.1 by EnergySoft User Number: 5553 RunCode: 2011-12-28712:02:41 ID: 2011 -GLS -025 Page 8 of 13
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5)
CF -1 R
Project Name
CAMARRELLA's Residence
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
12/28/2011
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existing Altered Removed Volume Year Built
EXISTING EXISTING
3,969
39,690 2004
Addition
315
3,150
Totals 3151 3,969 0 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. I Thermostat Type Status
EXISTING 2 Central Furnace
78% AFUE Split Air Conditioner 9.7 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
EXISTING Ducted
Ducted Attic, Roof Ins 4.2
❑ Existing
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
Kitchen Pipe Ins
40,000.
50
0.58
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
(ft)
0
i�
v N
a
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty. HP
Plenum Outside Buried
Energ Pro 5.1 by Ener Sok User Number: 5553
RunCode: 2011-12-28712:02:41 ID: 2011 -GLS -025
Page 9 of 21
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
CAMARRELLA's Residence
Date
11212812011
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent LI -factor.
*§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed ajccordinq to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandato Va or barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or facto -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACOA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
§150(i)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number. 5553 RunCode: 2011-12-28712:02:41 ID: 2011 -GLS -025 Page 10 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
CAMARRELLA's Residence
11212812011
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers. -
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
§150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms_, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number. 5553 RunCode: 2011-12-28712:02:41 ID: 2011 -GLS -025 Page 11 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
CAMARRELLA's Residence
11212812011
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be hi h efficacy luminaires.
§150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number: 5553 RunCode: 2011-12-28712:02:41 ID: 2011 -GLS -025 Page 12 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
CAMARRELLA's Residence
Date
12/28/2011
System Name
EXISTING
Floor Area
4,284
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 1,981
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 45,000
63,514
3,627 1,886
71,232
Total Out ut'(Btuh) 90,000
0
Output Btuh/s ft 21.0
5,386
5,061
Cooling System
0
0
Output per System 48,000
0
0 0
0
Total Output Btuh 96,000
0
3,627
0
Total Output (Tons) 8.0
5,386
5,061
Total Output Btuh/s ft 22.4
Total Output s fUron 535.5
74,286
81,354
Air System
CFM per System
0
HVAC EQUIPMENT SELECTION
Airflow cfm
0
Default FAU/AC 1992 - 2005 77,789
0
90,000
Airflow cfm/s ft
0.00
Airflow cfm/Ton
0.0
Outside Air (%)
0.0%
Total Adjusted System Output 77,789
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0 90,000
Aug 3 PM Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
68 OF
68 OF 107 OF
Heating Coil
105 OF
ROOM—�^
i
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air Ar
0 cfm AL
80/59°F
80/59°F 46/44°F
Cooling Coil 48 / 45 OF
29.7% ROOM
_ 78/58°F
EnergyPro 5.1 by EnergySoft
User Number: 5553 RunCode: 2011-12-28712:02:41 ID: 2011 -GLS -025 Page 13 of 13