Loading...
08-1573 (AR)P.O.. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description Property Zoning: Application valuation: Applicant: 08-00001573 80780 WEISKOPF, 762-160-013- - - ADDITION - RESIDENTIAL LOW DENSITY RESIDENTIAL 40000 T44yl 4 XP Q" - BUILDING & SAFETY DEPARTMENT Architect or Engineer: 0A ------------------ LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: 748605 License No.: B Date �oBi Contractor: �iQ,tti.� lJ ���__ OWNER -BUILDER DECLARATION ' I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPEILVIIT Owner: LAKE CHAUNCEY & anita 80780 WEISKOPF LA QUINTA, CA 92253 ( Contractor: LANG CONSTRUCTION 80590 CAMINO SAN GREGERI BERMUDA DUNES, CA 92203 (760)834-.9020 Lic. No.: B VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/13/08 ----------------------------------------------— WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 1889409 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date � �A�pplicant: 'V WARNING: FAILURE TO SECURE WORKERS' COMPENS ION COVERAGE IS UNLAWFUL, AND SHALL - SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($1.00,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this countJJy toe2znte Tupon the above-mentioned property for.inspection purposes. Date: Signature licant or Agent): f lLLaI <." i LQPERN7IT Application Number . . . . . 08-00001573 Permit BUILDING PERMIT Additional desc . Permit Fee . . . . 349.50 Plan Check Fee 227.18 Issue Date . . . . Valuation . . . . 40000 Expiration Date 4/11/09 Qty Unit Charge Per Extension BASE FEE 252.00 15.00 6.5000 ----------------------------------------------7------7---------------------- THOU BLDG 25,001-50,000 97.50 Permit . ... ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 19.66 Plan Check Fee 4.92 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/11/09 Qty Unit Charge Per Extension BASE FEE 15.00 133.00 ..0350 ---------------------------------------------------------------------------- ELEC NEW RES - 1 OR 2 FAMILY. 4.66 Permit . . . MECHANICAL Additional desc . .. Permit Fee . . . . 37.00 Plan Check Fee 9.25 Issue Date . . . . Valuation . . . . 0 Expiration Date 4/11/09 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 2.00 6.5000 -------------------------------- EA MECH VENT =------------------------------------------- FAN 13.00 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 42.00 P1an'Check Fee 10.50 Issue Date . . . Valuation . . . . 0 Expiration Date 4/11/09 Qty Unit.Charge Per Extension BASE FEE 15.00 4.00 6-.0000 EA PLB FIXTURE 24.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 ---------------------------------------------------------------------------- Special Notes and Comments. 133 SQ. FT. BATHROOM ADDITION AND Application Number . . . . . 08-00001573 ---------------------------------------------------------------------------- Special Notes and Comments REMODEL ----------------------- ..Other Fees . . . . . . . . . ----------------------------------------- ENERGY REVIEW FEE 22.72 STRONG MOTION (SMI) L RES 4.00 Fee summary Charged ---------- Paid Credited Due -----=----------- Permit Fee Total 448.16 -------------------- .00 ---------- .00 448.16 Plan Check Total 251.85 .00 .00 251.85 Other Fee Total 26.72 .00 .00 26.72 Grand Total 726.73 .00 .00 726.73 LQPE%IIIT Bin # !G) n Cit/ of La Quin Building &r Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # ' Project Address: 80-780 Weiskopf Owner's Name: Chauncy & Anita Lake A.P.Number: 762-160-013 Address: 80-780 Weiskopf Legal Description: Lot #46, Tract 28444 City, ST, Zip: La Quinta, CA 92253 Lan Construction Contractor: 9 Telephone: ( Address: 80590 Camino San Gregorio Project Descr iption: Construct approximately 133 sq ft City,ST,Zip: Indio, CA 92203-7434 single story restroom addition onto existing Telephone: (7 6 0 ) 702-7744 : » ::>::•::•.?:<>::>:::>1i:>><: <:::::: "'�''"�������^"'"�� City Lic.#;10-0001020 home. It is wood framed construction, with the State Lic.#: B-748605 exterior and roofing to match existing residence Arch., Engr., Designer: Larry W. Lang, P.E. Address: 80590 Camino San Greqorio City, ST, Zip: Indio, CA 92203-7434 76 7 2-7744 0 Telephone: ( ) 0 Con structi n T v o e: - Occupancy: :Sin le Family P Y g Y e i .#. CA -35749 StatLc Project t tAlter Repair Demo Name of Contact Person: Larry W. Lang Sq. Ft.: 133 # Stories: 1 # Units: 1 Telephone# of Contact Person: (760) 702-7744 Estimated Value of Project: $40,000 . APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted '� Item Amount Structural Calcs. Z Reviewed, ready fccorrectionfl, Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up 0r Z) Construction Flood plain plan Plans resubmitted 01.2 Mechanical Grading plan 2 Review, ready for correctio s/issue Electrical Subcontactor List Called Contact Person O Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue �Q School Fees N — V Total Permit Fees is R C- Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA:, AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MMGA17ON AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name:Chauncey Lake (PGA West) Date: October 14, 2008 Owner's Name: Chauncey Lake Phone No. (760) Project Address: 80-780 Weiskope, La Quinta, CA 92253 Project Description: Room Addition APN: 762-160-013 Tract #: Lot #'s: Type of Development: Residential C Commercial Industrial Total Square Feet of Building Area: 133 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: 10/14/08 Signature: *********************************************************************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code Project 65995 Approval 133 sq. ft. $ 0.00 $ 0.00 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Support Services Certificate issued by: Leticia C. Torres, Facilities Analyst Agreement Existing Not Subject to Fee Prior to 1/1/87 Requirement Note: Pursuant to AB -181 any room additions to existing dwelling units of 500 sq. ft. or less are exempt from developer fees. Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires tha Is District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the' latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance less 3% for Administrative Fees to process the reimbursement. MV:c/mydocs/devfees/certificate of compliance form tablesTO USE.doc 1/16/03 T SEP/10/2006i'1!+Er 02.41 'N Monarch Management 1 HX No. 760 776 5111 P. 002/002 )FAIRWAYS ASSOCIATION September 10, 2008 Chauncey & Anita Lake 80-780 W63kopf La Quints, CA 92253 Re: Architectural Application - 80-780 Weisskopf - APPROVED rear Mr. Lake: The Axchitecacusal Committee reviewed your plans submitted for the constriction of your room addition. I amt pleased to notify you that the Atchitecu=1 Com=ittee has approved your application as submitted. When completed with your: project, ple ase fil]. out an ExbXbit C £nun and send into the office for Final Inspection of your pilopeity. If you should have any questitons in xegaxd to this coxtespondence please do not: hesitate to contact the Association at any time. Sincerely, On Beha!f ofthe.FSA iWEST4'9stv&don By: Jamie Saldivai PGA WEST Fanways Operations Manager Fo.t the A='hitecuual Committee Cc: File Post Office Box 1690 • La Quints, California 9:.%247 - Phone (760) 776-5100 • Fax (760) 776-5111 L ''fir -!'-r780 N.'4th Street x 77-948 Wildcat Drive El Centro, CA 92243 —Palm Desert, CA 92211 (760)370-3000 ANU'M'ARK 2 - (760)360-0665 (760) 337-8900 Fax -Geolooists (760)360-0521 Fax SPECIAL INSPECTION REPORT Special Inspection Reports must be distributed to the parties listed below within 14 days of inspection. Reports of non-compliant DSA File # conditions must be distributed immediately. Separate reports shall be prepared for each type of special inspection, on a daily basis. DSA Appl # Each report shall be completed and signed by the special inspector conducting the inspection. DSA/LEA # Project Name: L G,Ie- tom, re- 5 c e ocs, Date: NOV -/q ;O$ Client Project #: O$ 19 S Time Arrived: Project Location: g d -7 Ito (_A)Pi.5k9QL IA:Qu iert-,q Time Departed: Contractor: JN�[�,�yr�,lj�pry Bldg. Permit#: �X7� Travel Time: Type of Inspection ❑ Batch Plant ❑ Masonry ❑ Fireproofing ❑ Engineered Fill ❑ Prestressed Concrete ❑ High Strength Bolting ❑ Foundation ❑ Shotcrete ❑ Welding ❑ DSA Approved Documents: Work Inspected: �5.0't 11ph IV%!; -Q ! 2 P Yga A...._k5 o t G4_5 d ac�d t a v► �L� (�o c�JS (1 S r4p 1zt✓ 1621114 �s� w►P w -t— �'2 o c_. D -e r y on 5 3 PJ,-Ck–f 4di 14 'f0 to a N ,jun% A Set �i� �- 30-10 qA- IZ2--1411RA E The Work ❑ was [—]was not NA Inspected in accordance with the requirements of the DSA approved documents Material Sampling ❑wastjA4 was not n/a Performed in accordance with DSA approved documents cc: Project Architect Structural Engineer Project Inspector DSA Regional Office School District The Work Inspected ❑ metMM- did not meet The Requirement of the DSA A. pproved Documents . Signature of Special Inspector _P"W_ INS . t�Sofz Print Namerritlee Certification #52-q 0 5 " TITLE 24 REPORT Title 24 Report for: LAKE ADDITION 80780 WEISKOPF LA QUINTA, CA 92253 Project Designer: LANG CONSTRUCTION LARRY W. LANG 760-702-7744 Report Prepared By: KAY THOMAS T&K Engineering CITY OFAve. Buena Suerte BUILDING & gq NTXe ecula, CA 92591 DEPT. (951) 699-0436 APPROVED FOR CONST UCTION �',c44, 1 �� , DA Job Number: ORIG 8-28-08 Date: 8/28/2008 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoh, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: ORIG 8-28-08 User Number: 3089 TABLE OF CONTENTS I Cover Page 1 i Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 7 jHVAC System Heating and Cooling Loads Summary 9 4.4 by EnergvSoft Job Number: ORIG 8-28-08 User Number: 3089 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R .................... .......... . .... .. .. ................ .. OPAQUE SURFACES ..... ..... . __...._.........--_8128/2.08 -._ ProjectTitle Dat.!i . ......... Cay. Cont. Azm. -.8078.0-M.E.I.S.KOPE L&QUINTA .... . . .......... .............. . . .. .. . .... ........... . . ............................................. .... ........ .. ... . ... . ..... [Building . .................................. . .......... . Project Address 017AII& . . . . ............................ . . ... ENTIRE.ADDI.TION..----...--..--- Permit# _.....R-21 R!0.0....__ _0_.- .. X ..9 0 1 New_ 09zA6-, ENTIRE.ADDITION-.- . . ......... .. ----------- ._T_&.K.Enqine.ering._... . ............. Documentafion Author 09-A6 Telephone -- Plan Check/Date IN lNew-, Enerqv,Pro-.. . ..... . .... .. CA -Cl i mate. Zon e -1.5 Fi'ld�Che60Ui_i_" CompliNfice Method . ... ... -.11 . ................... . . . ............... ..... . ....... . . . . . . ................. I ............... .. .............. . .................. . .......................... . .. . ....... . . .......... . . Climate Zone . ............... .............. . ..... . .... . . ......... . . I...., ................. ........... . .. - --------- ---- . . ..... IJ ---- TDV Standard Proposed Compliance . ....... ­­­­ ........... . . .. . . . . ...... (kBtu/sf-yr)___,ign _ I _q�s Degn Design - .. - - Min . ........... . . ...... _... Space Heating 1.95 0.35 1.60 Space Cooling 88.13 85.16 2.98 . . ........................ ................... . .. . . . . ........................... ............... Fans 12.57 12.24 0.34 Domestic Hot Water 0.00 0.00 0.00 Pu P5 0.00 0..........0..... 0I.. ...... 0.00 .... .... . ...... Totals 102.65 97.75 4.91 EnergyPro 4.4 by EnergySoft Percent better than Standard: Number. ORIG 8-28-08 . .. . . ........ 4.8% BUILDING COMPLIES NO HERS VERIFICATION REQUIRED Building Type: Xf Single Family X Addition Total Conditioned Floor Area: 133 ft' .;Multi Family Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (W) 270 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 133 ft' Fenestration: Average Ceiling Height: 10.4 ft Area: 6ft2 Avg. U: 0.34 Number of Dwelling Units: 0.23 Ratio: 4.5% Avg. SHGC: 0.39 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type . . Hgt. Area EXISTING.HEAT.. - - - --------- ...... .... . . ...... ..... . ........ _133 .___.1,383 . ............. . .. .. .. ........ ....... . . . ........ .... .... . . . . . . . . . ................... 0.23-, ..Conditioned ......Setback .. . . ....... ... . ..... . ..... ... . . ......... .. . ....... . ..... ........ ........ .... . . . ......... . ....... . . __.-....2 n/a .................... .......... . .... .. .. ................ .. OPAQUE SURFACES .. . ....... . ....... . .................. . I .... .............. Insulation Act. .. .... ...... 11 . .... .... ...... Gains Condition ...... ... Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y/N Status JA IV Reference Location Comments .Roof Wood, 133, .0 025 R-38 R-0.0 0 22 XI New... . 017AII& . . . . ............................ . . ... ENTIRE.ADDI.TION..----...--..--- Wall. W.00d--.-- _-.26. 0.069_ _.....R-21 R!0.0....__ _0_.- .. X ..9 0 1 New_ 09zA6-, ENTIRE.ADDITION-.- -Wall-.. Wood-.---.. __.R21.­Rn0A ___90 . __._90 X !New 09-A6 ENTIRE ADDITION Wall Wood-- _21. D.069, _R721-1 R-0.0,_ 180-_90 IN lNew-, 09-A6.....__ ENTIREADDITION . . ............ . ....... . .... ....... ..... . ............. . ..... ... .. . ...... . ............. .... ... .. . ................... .. . ............. . ... ... -.11 . ................... . . . ............... ..... . ....... . . . . . . ................. I ............... .. .............. . .................. . .......................... . .. . ....... . . .......... . . - ----------- - ......... . ....... . . . . ....... ............. .... ... . . .. . ......... ... . .. - . . ....... . ....... . ............... .............. . ..... . .... . . ......... . . I...., ................. ........... . .. - --------- ---- . . ..... IJ ---- ............. ...... .. ..... .. . ....... ............ . ... . .. . . .... ......... . . . ........ . ....... ... . ..... ....... ..... . .... . . . . ............ . . .. .. ... . . .... ..... . ..... ._ . ........... . . ....... . . ....... ­­­­ ........... . . .. . . . . ...... - 1 H I __.. .._ . I........ . ......... . F_ - - - - . .. . . . . ... . .................. . . ....... ...... . ... ...... . .... . ... . . . . . . .. . ..... .. ..... .. ............... ... .. ..... ......... ........................ . .. . ... ........................ .. .... .... ....... . . . ........... ..... . . .. ..... . ... ...................... . . .... . .............. . ................... . .. - - ------- -- ... .... . .. ........ . . . . ............................................... .. . ................. . .... ... ... .. . . . ........ . .................................. ................ .. ..... . . ..... H ............. .......... .................. . . ........................ ................... . .. . . . . ........................... ............... ....... . ... .................................. .. .......... . . .............................................. ........ . ..... .............. . ..... ...... ........................... . ........... . .. ......... . . . ......... ... . ............ . . . ...... . Run Initiation Time: 08/28/08 10:37:06 Run Code: 1219945026 EnergyPro 4.4 by EnergySoft User Number: 3089Job Number. ORIG 8-28-08 . .. . . ........ . ....... ............. ....... . . Page:3 of 9 .......... THERMAL MASS FOR HIGH MASS DESIGN 4.4 by EnergySoft User Number: 3089 Job Number: ORIG 8-28-08 of 9 Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete Heavyweight .._..___ .. ,105 3.50 28 0.98 0 26-A1 _ -- _ _ _ New.______._— ENTIRE_ ADDITION / Slab on Grade Concrete, Heavyweight____ 28 3.50 28 _0_98 2 26-A1 — _ _ New ENTIRE ADDITION / Slab on Grade _^ Insulation Condition Location/ PERIMETER LOSSES Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 24 None No Insulation 26 -Al*"... New _- ENTIRE ADDITION . ...... . ....... ___-......,_...,..—_ 4.4 by EnergySoft User Number: 3089 Job Number: ORIG 8-28-08 of 9 Certificate Of Compliance • Residential (Part 3 of 4) CF -1 R LAKE ADDITION 8/28/2008 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type EXISTING HEAT Central Furnace 80% AFUE No Cooling 13.0 SEER Existing Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? EXISTING HEAT Ducted Ducted Attic 4.2 Existing No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Water Heater # in /stem Name Type Distribution Sys Rated Tank Energy Tank insul. Input Cap. Condition Factor Standby R -Value (Btu/hr) (aal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft)_ Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: LANG CONSTRUCTION Address: LARRY W. LANG Telephone: 760-702-7744 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: KAY THOMAS Title/Firm: T&K Engineering Address: 30535 Ave. Buena Suerte Temecula, CA 92591 Telephone: (�9 1) 699-0436 ; �/ (signat r)41)4 (date) I FneravPro 4.4 by EnergvSoft User Number: 3089 Job Number: ORIG 8-28-08 rage:o or a i Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R LAKE ADDITION _ 8/28/2008 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies uaoeu Un the auequacy ur the speciai Jusancatnon ano aocumentation suarnmea. I Plan Field The Roof "R-38 Roof Attic" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. HIGH MASS Design -Verify Thermal Mass: 105 sgft Exposed Slab Floor, 3.50" thick at ENTIRE ADDITION HIGH MASS Design - Verify Thermal Mass: 28 sqft Covered Slab Floor, 3.50" thick at ENTIRE ADDITION HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a yIvaucI U—Itf adsFI—VU L—L—U anwan VCIM1 aIIU11 meuwus. Plan Field I i I Run Initiation Time: 08/28/08 10:37:06 Run Code: 1219945026 EnergyPro 4.4 by Energysoft User Number. 3089 Job Number: ORIG 8-28-08 Page:6 of 9 H Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents. the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE-' DESCRIPTION permit application documentation. .._ ..... _._.._.._.__.._....._. _. NIA DESIGNER MENT j Building Envelope Measures c 150(a): Mininwm R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. 150(b): Loose fill insulation manufacturers labeled R -Value: —, t ; 11-1 _1 § 150(.): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls). +§ 150(d): Minimum R-13 raised Floor insulation in framed floors or equivalent U -factor. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: I a. closable metal or glass door covering the entire opening of the firebox b, outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed. , I § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor permeance rale no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include CF -6R Form: _ ..._.__.................._ __....__........._ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. I X? having an installed thermal resistance of R-12 or greater, ; , i I a I Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment. water heaters, showerheads and faucets certified by the Energy Commission. i 1 tt § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA. § 150(1): Setback thermostat on all applicable heating and/or cooling systems. § 1500): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater, j j 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation and indicated on the exterior of the lank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water healer tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 1508. 2. Coolingsystem piping suction, chilled water, or brine lines). piping insulated between heating source and Y PP 9(� ) 0 _� r indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. i 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, — r ID �__ } and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation, (' �� `. _..__....._.—..__.—....... ---... _................ ........ ------—._...._............. ........... _........ .. Lnergytr 4.4 by Energy5oft User Number: 3089 Job Number: ORIG 8-28-08 — __. w_ .. _ --........ --- . _ ._ ,- .. ,,._._._.. _._._ .-_._ — --- — ---. _..._._.._............. _............... .... —_ w.. Page:7 of 9 U Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. __. __...._ .... _....... ........... _.._ ...... _.__. _..____ _ .._._.._ DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. NIA DESIGNER MENT - ... __.. __........._.._.___._.-._. ....... . Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, X t 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than seated sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36' of pipe between filter and healer for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. § 115. Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 1 § 118 (i): Cool Roof material meets specified criteria Lighting Measures j § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § I50(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft} OR are controlled by a dimmer switch OR are controlled by an occupant sensor that complies with Section 119(d) that daes not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k): Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). -... ..... _._ IEnergyPro 4.4 by EnergySoft User Number: 3089 Job Number: ORIG 8-28-08 l lXI rX.i C I 1X) L . i II 1XI 1 I l lXI i tX t J t ix► I l lXI tX t J I.1 lJ Pa9e:8 of 9 (HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY .... .......... ------ - - - - - - - - - -­-­­ IPROJECT NAME DATE LAKE ADDITION 8/28/2008 NAME .. .. ................ FLOOR AREA EXISTING HEAT 133 . ....... . ... . ....... . . . ..... ... . .................... . ...... ................................... . .. . .......... . ._ . ... . . . ...... ...... . . ........ . . ......... ..Number of Systems I ....... . . ....... . ... . .. . .... .... . ........ .... . . ............ . .... ..................... ... .. . . .. .......... __ ....... . . .. ...... . ......... COIL COOLING PEAK 1$:COILHTG.PEAKH -._._COIL .... .................... ........... ... I .... ..... . . .. . .. ............... ... . ........... . ..... . ....... . . .... ........... . ......... .................. . ...... . ...................... ..... .... .. Heating System ng .............. . .... . ...... CFM I Sensible! Latent CFM Sensible .1; Output per System . . .... 3,325' N Total Room Loads 18 3,706 � . . ........... . . .... . .. . ........ .. ..... - 78 0. 591 . ..... . ........ . - 2,197 Total Output (Btuh) . . . ........... . ...... 3,325 Return Vented Lighting 0! Output (Btuh/sqft) 1 25.0 Return Air Ducts 6541 315 1 Cooling System Return Fan i 0i ............ .. . . 0 Out ut per System p . . .. ........ . ........ .. . ............. .. . ....... ...... ... . ... . . . ... ....................... ......... ........ . .... ............. ... . Ventilation 5 ... . . ................. . . ........... . .... .... ...... 2161i Total Output (Btuh) 0 Supply Fan 0; ... .. ..... ... ­ .... . . .......... ............. ... .................... ..................... .. ..... .......... Total Output (Tons) ..... .... ..... . 0.0 ..... Supply Air Ducts ...... ... ....... 654. 1 . ............. 315; Total Output (Btuh/sqft) O.Oi ... TOTAL SYSTEM LOAD ....... ......... ..... 4 195 - .. .............................. 7791 L --------. ....... 3,041 Total Output (sqft/Ton) 0.0 L-- .................................. ................ . .. . . . .................. . ..... . ..... ............. . . .. . . - Air System ..... .. . .............. . - --- --- 1HVAC EQUIPMENT SELECTION CFMper System ....... . . . . ....... . . ........................ .. ...... .. . ... . .. 0 i.111 HEXISTING . ...... . ..... ......... ... ........ TRANSFER HEAT0 ...... . ........ .... ; . . . . ............ ........... 3,32 Airflow (cfm) 0 Airflow (cfmlsqft) 0.00 . ....... 1 Airflow (cfm/Ton) Outside Air 00i Total Adjusted System Output m ns) (Adjusted for Peak Design Conditio 0: _3 3251 Outside Air (cfm/sqft) 0.03 TIME OF SYSTEM PEAK . .. . . ..... .......... Au 2 m g- ­ ­­ p Jan 12 am! Note: values above givenat ARI conditions .. .............. ..... ... .... . ......... .... ... .. . . .................. . . . . . . . . . . . .................................................... . ................... . . . . . . ...... ..... ............... . ...... .... .. RATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26.0 OF 70.0 OF Outside Air 5 cfm 70.0 OF 105.0 OF 41 pply Air Ducts Heating Coil I < Return Air Ducts .... ....... .. .... . ...... . ......... . .............. . ... . ..... ......... .. . I . . ..... ......... ........... . ............... FOOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) 11.0 172.5 OF Outside Air 5 cfm 74.0/61.0 of 74.0/61.0OF = 55.0/53.80F Cooling Coil 105.0 OF . .......... . .................. . ......... . ....... . 70.0 OF � Supply Air Ducts � 55.0 / 53.8 OF 47.5% R.H. L-90—wad, 74.0 61.0 OF Return Air Ducts .. . .... . ......... EnergyPro 4.4 by EnergySoft User Number: 3089 Job Number: ORIG 8-28-08 Page:9 of 9 SUPPLEMENTAL HEATING COMPLIANCE DATE: AUGUST 28, 2008 FROM: T & K ENGINEERING 30535 AVENIDA BUENA SUERTE TEMECULA, CA 92591 951.699.0436 TO: BUILDING & SAFETY FOR! TITLE 24 ENERGY CALCULATIONS COMPLIANCE WITH CALIFORNIA ENERGY COMMISSION REQUIREMENTS. PROJECT TITLE OR OWNER: LAKE ADDITION 80780 WEISKOPF LA QUINTA, CA 92253 Owner certifies that the existing heating unit produces: 31,000 btu Owner certifies that the existing residence conditioned floor area is: 422 sf Building & Safety requirement for existing is 25 btu/sf or: 25 x 422 = 10,550 btu T & K ENGINEERING calculations for the addition using the state approved Energy Pro computer modeling program calls for a heating load of: 3,325 btu Total heating load for the existing + addition: 13,875 btu load Existing heating unit is adequate for existing + addition: 31,000 btu available vs. 13,875 btu load Signed, T & K ENGINEERINNG/, KATHWAS