04-3556 (SFD)Q&rav
BUILDING & SAFETY DEPARTMENT
P.O. BOX 1504 (760) 777-7012
78-495 CALLS TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153
BUILDING PERMIT
Application Number . . . .
Property Address . . .
APN:
Appl.ication description
Property Zoning : . ...
Application valuation..
30556 - Date 4/22/04
60573 WHITE SAGE DR
764-270-999-72 -300231-
DWELLING - SINGLE FAMILY DETACHED
LOW DENSITY RESIDENTIAL
168537
Owner
_ _ �_ �y Contractor
--------------------
SHEA LA QUINTAI
-- ------------------------
"`� �° !SHEA HOMES, IVC.
�.� -WV 2 2
C/O JEFF MCQUEEN
`_- .r
--w;�',8-1260 AVENUE 62
8.800 N GAINEY CENTER
Tb -0"'x, � LA QUINTA
���
CA 92253
SCOTTSDALE
�
LAZ 8525'$ ���u (760) 777-6005
WCC: NTL JNION
INS
WC: 7165833
08/01/04
CSLB: 672295-.
06/30/05
CCC: B
--------------------------
Structure Information ----------7--------------
Construction Type
. . . . . TYPE V - NONRATED
Occupancy Type .
. . . . . DWELLG/LODGING/LONG <=10
Flood Zone
NON -AO FLOOD ZONE
Other struct info
CODE EDITION
2001 CBC
FIRE SPRINKLERS
NO
GARAGE SQ FTG
576.00
PATIO SQ FTG
177.00
NUMBER OF UNITS
'1.00
FIRST FLOOR SQ FTG
1917.00
-----------------------------------------------------------------------------
Permit ... . . .
. BUILDING PERMIT
Additional desc
Permit Fee
881.00 Plan Check Fee
143.16
Issue Date
Valuation
.168537
Qty Unit Charge
Per
Extension
BASE FEE
639.50
69.00 3.5000
THOU BLDG 100,001-500,000
241.50
-----------------------------------------------------------------------=----
Permit . . . .
. MECHANICAL
Additional desc .
Permit.Fee . . .
.. 80.00 Plan Check Fee
20.00
Issue Date... . .
. Valuation
0
Qty Unit Charge Per Extension
1
P.O. BOX 1504 a U�/; , t
7E-495 CALLS TAM►ICO �/ VOICE (760) 777-7012
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
INSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT
Application Number: 0 41 ' �. .�(o Date:
Applicant: Eng'
-- & S)i--
ft or Engineer's Adess:
&h 'A V
Lic. No.- Lq&) -
i2wn.Lima rr-KMI I ULULARATIONS
uncle
1 hereby afrawn LICENSED CONTRACTOR'S DECLARATION
rally, d perjury tat I am licensed under provisions of Chapter 9 (oormhenonp with Section 7000) of Division 3 of to Business and Rotessionals
fod6 a/Lice WI force and affectLicense Class No—62
Date . `Z52 .
1 hereby affrm under penalty d perjury Oat 1 am OWNW-BU DER DECLARATION
�y or �y tat repr
i es a pahwhil b Construct• Sher. from to Cahtractois' stab License Law for the foMowirq reason (Sec 7031 b. Busihess and Pnobssionh Code Any
Wlertherrt Oat he a shhe is licensed �• er � any ' Orion b its "once. also nK*U to applicant for the pena0 b Sea spnad
thePfOlesslOnS p is e e ire povinx, d to Cahtraebrs' State License Law (Chapter 9 (cwwnwwdng with Section 7000) d Division 3 d Ore awkum
app Civil ) or Opal he or she k exempt imarefnonrw and time basis for Oho alleged exenp6 WL Any violation d Section 7031.5 by any appk= t for a pmmit subjects
(..► I. ss Cowmen d toe f d not mere tan five INandred datars (5500).r
OropattY. or MY employees with wages as their sob Cortpersaion, will do the work, and the strucure is not trwb
ProfessionsBusiness and Codndee a otkned for sok (sec ?o44..
t s~ The contractors! stab Lberse Law does not apply b an owns d property who builds or improves thereon, and who does the work
said within one t1f o1� his or her own errpbyees. provided Oat the iMxovenher ft are not intended or offered for sale. It. however, the buidirg or inprovenam a
(.) 1, as owner d the Year of p
cor ktion• the owner -builder will have thd at e burden pmvwV the or she did im
not build or prove for the purpose at sale.).
State License Law does not es wviflh licensed Contractors bnsct Oa CotruProject (Sec 7044. Business and Professions Code: The Contractors•
the Contracbrs' Stab LicenseLa ) an owner d pnvperty who builds or irpmves taiaon. and who contracts for the projects with a contracior(s) licensed pursuant b
U I am exempt under Sec. . aA P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
1 hereby affirm under penalty of perjury one Of to following durations:
_ 1 have and will ormaintain • Certificate d Consent b seff4rhsure for work r�rr>pensafca, as provided tion by Section 3700 d the Labor Code. for the peAannamoe
/ d the work for which Itis per.. is Issued.
I have and will maintain workers! Einsmr100 as regained by section 3700 d the Labor Code. for the performance d the work for which this per., Is
00rtpe^��n NSC perch and policy number ace:
I Cftty IhK in ft Dafomanccs Of the work for which this p eis icwed. I shall no(empby any person in any manner so as to become subject b the workers•
ConqM 'OF; Callommia• and agnea 01N I should become subject 10 to workeW compensation provisions d d the section 3700 Labor Cshall
b
Code. I
I rohwitm coapt with those provisions.
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CML FINES UP TO ONE HUNDRED THOUSAND DOLLARS (=100.000). IN ADDIT N TO THE COST OF COMPENSATION. DAkAAGES AS PROVIDED FOR IN
SECTION OF THE LABOR CODE, MEREST. AND ATTORNEYS FEES..
I hereby affirm under penalty d perjury tat two is a Constnrrdiorh CONSTRUCTION LENDING AGENCY
ft Widig agency for the performance of the work for wh id this pet.. is issued (Sec. 3097. Civ. C.).
Lendefs Name
Lenders Address
IMPORTANT Application is hereby made b the Direcbr of APPUCANT ACKNOWLEDGEMENT
1. Each person upon whose behalf Itis is Building and Safety for a permit subject b the Conditions and restrictions set forth on this application,
Issued
as a rests d Ort behal ion, �� Vie. each person at whom ro*" and for whose benefd work a performed under or pursuant b any pamhit
dlicers, agents and employees for arty act or omission retaa�to the woach rk io and heda, under
rera. iraemnity and hold f often the City d la OuMmta. Its
2 Any perm issued as a result d this application becomes null and void if wads noperformed
o m eno�ed wit n 180 days dfollcowing issuance ilate d Issuance of such per,. or
cessation d wok for 180 days will subject per., b cancellation.
1 Certify that I e d read thisOuth0d:eseniat
appigion s aboveInfomationisI agree b Comply with as city and county ordinances and state haws rofainp b buk*V
of this Y er the above-mentioned property for inspection purposes.
7 0 -(Applicant or Apart).
I�
Application Number
04-0.0003556
Page 2
Date 4/22/04
Qty
Unit Charge
Per
Extension
BASE
FEE
15.00
1.00
9.0000
EA
MECH
FURNACE <=100K
9.00
1.00
11.0000
EA
MECH
FURNACE >100K
11.00
1.00
9.0000
EA
MECH
B/C <=3HP/100K BTU"
9.00
1.00
16.5000
EA
MECH
B/C >3-15HP/>100K-:OOKBTU
16.50
2.00
6.5000
EA
MECH
VENT FAN
13.00
1.00
6.5000
EA
MECH
EXHAUST HOOD
6.50
----------------------------------------------------------------------------
Permit .
. . . . .
ELEC-NEW
RESIDENTIAL
Additional
desc . .
Permit Fee
. . . .
93.62
Plan Check Fee
23.41
Issue Date
. . .
Valuation . . . .
0
Qty
Unit Charge
Per
Extension
BASE
FEE
15.00
1917.00
.0350
ELEC
NEW RES - 1 OR 2 FAMILY
67.10
576.00
.0200
ELEC
GARAGE OR NON-RESIDENTIAL
11.52
----------------------------------------------------------------------------
Permit .
. . . . .
PLUMBING
Additional
desc
Permit Fee
. . . .
152.25
Plan Check Fee
38.06
Issue Date
. . . .
Valuation . . . .
0
Qty
Unit ✓Charge
Per
Extension
BASE
FEE
15.00
14.00
6.0000
EA
PLB
FIXTURE
84.00
1.00
15.0000
EA
PLB
BUILDING SEWER
15.00
1.00
7.5000
EA
PLB
WATER HEATER/VENT
7.50
1.00
3.0000
EA
PLB
WATER INST/ALT/REP
3.00
1.00
9.0000
EA
PLB
LAWN SPRINKLER SYSTEM
9.00
5..00
:7500
'EA
PLB
GAS PIPE >=5
3.75
1.00
15.0000
EA
PLB
GAS METER
15.00
----------------------------------------------------------------------------
Permit .
. . . . .
GRADING PERMIT
Additional
desc
Permit Fee
. . . .
15.00
Plan Check Fee
.00
Issue Date
Valuation
0
Qty
Unit Charge
Per
Extension
BASE
FEE
15.00
Fee summary Charged
Permit Fee Total 1221.87
Plan Check Total 224.63
Other Fee Total 2440.17
Grand Total 3886.67
Paid Credite3 Due
---------- ---------- ----------
.00 .00 1221.87
.00 .00 224.63
.00 .00 2440.17
.00 .00 3886.67
Page
3
Application Number . . . . .
04-00003556 Date
4/22/04
----------------------------------------------------------------------------
Special Notes and Comments
SFD LOT 72 PLAN 4520A. PERMIT
DOES NOT
INCLUDE BLOCK WALL, POOL, SPA
OR
DRIVEWAY APPROACH.
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
ART IN PUBLIC PLACES -RES
.00
DIF COMMUNITY CENTERS -RES
98.00
DIF CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE
14.32
DIF FIRE PROTECTION -:SES
98.00
GRADING PLAN CHECK FEE
.00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
6.00
DIF PARKS/REC - RES
503.00
STRONG MOTION (SMI) - RES
16.85
DIF STREET MAINT FAC -RES
15.00
DIF TRANSPORTATION - RES
1098.00
Fee summary Charged
Permit Fee Total 1221.87
Plan Check Total 224.63
Other Fee Total 2440.17
Grand Total 3886.67
Paid Credite3 Due
---------- ---------- ----------
.00 .00 1221.87
.00 .00 224.63
.00 .00 2440.17
.00 .00 3886.67
Installation Certificate: Residential
Site Address
60-573 White Sage Drive
.4 or 7!1
1. BUILDER INFORMATION
Shea Homes - Trilogy - LaQuinta
60311 Trilogy Pkwy
La Quinta, CA 92253-7642
INSTALLING CONTRACTOR:
2. PROJECT INFORMATION
DISTRIBUTION
TYPE
Flexible Ductwork
in Attic and
Between Floors
DUCT OR PIPING R -
VALUE
Flexible Ductwork
Will have a R -Value
of 4.2 or Better
CF -6R
PERMIT #
OIL 3 S e
SUBDIVISION: Trilogy P, La Quinta
CITY: La Quinta
COUNTY: Riverside
WEST PAC AIR CONDITIBNING
I, the undersigned, verify that the equipment listed in the category above my signature is the actual equipment
installed and that the equipment meets or exceeds the requirements of the Appliance Efficiency Standards. In
addition, Ihave verified that the equipment is equivalent to or more efficient than the equipment specified on the
Certificate of Compliance submitted to demonstrate compliance with the Energy Efficiency Standards for
residential buildings.
3. HEATING INFORMATION
HEATING MANUFACT HEATING UNIT ACTUAL EFF. HEATING EQUIP HEATING
EQUIP. MAKE MODEL # AFUE CAPACITY LOAD
Furnace Lennox
G40UH48B-090X
80% 88000
80%
4. COOLING INFORMATION
COOLING MANUFACT
COMPRESSOR
ACTUAL EFF. COOLING EQUIP COOLING
EQUIP. MAKE
MODEL #
SEER CAPACITY LOAD
A/C Lennox
13ACC-048
12
The building design heat loss and design heat gain rate have been determined using a method specified in Section
150(h) of the Energy Efficiency Standards, and are two of the criteria used for equipment s.zing and selection.
6.THERMOSTATIC EXPANSION VALVE (TXV):
Thermostatic Expansion Valve (or Commision approved equivalent) is installed and access is provided for inspection.
`'es ❑ No ❑ N/A ❑
6. SUBMITTED BY
Cry 7Grra _ nCU U? -7 � DATE: (;�_ 3C9 P 0 y
Signature Installing HVAC Contractor