Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
04-3830 (AR)
�� A �• "..-.,ter` `ij`1 BUILDING oG SAFETY DEPARTMENT P.0. Box 1504 (760).7777'7012 C� OF94%� 78-495 CALLS TAMPIco FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760)777-7153 BUILDING PERMIT Application Number 04-00.003830 `f Date 5/04./04 Property Address 44310 -`WILLOW CIR APN.: _ 604-092-020-58 -22982 - Application description. :,ADDITION — RESIDENTIAL Property Zoning LOW DENSITY RESIDENTIAL, Application.valuat.ion 24596 Owner. Contractor DEGEARE DAVID & KELLY DEGEARE BUILDERS, INC. 44310 WILLOW CIRCLE 42335 WASHINGTON STE, F.#344 - LA QUINTACA 92253 PALM DESERT CA 92211 . 4WCC : STATE FUND OWC: 130142004 01/01/05 ,.. CSLB: 795830- 06/30/0.5 :®CCC: B. ----- Structure Information 410.OFFICE ./ T.V. ROOM ADT:. ---- Construction Type . . . TYPE V'- NON RATED Occupancy Type. . . . . . DWELLG/LODGING/CONE.<=10 Flood Zone NON -AO FLOOD ZONE .Other struct info CODE EDITION- "2001 CBC' FLOOD - ZONE NO FIRST ,FLOOR SQ. FTG 430.00 Permit.. BUILDING _PERMIT Additional desc". Permit..Fee 252.00 :. Plan Check'Fee ,. 163.80 Issue Date Valuation. 24596 Qty Unit Charge Per Extension BASE FEE 45.00 -.23 00- 9.0000 THOU. .BLDG 2,001-25,000 207.00 Permit . . . . . ELECT,-.ADD/ALT/REM Additional. desc Permit Fee 39.05 Plan Check Fee' '-9 76 Issue Date Valuation 0 Qty, .Unit Charge Per-, Extension BASE.FEE 15.00 430.00 .0350 ELEC NEW RES 1 OR 2 -FAMILY 15:05 20..00 .4500 EA. ELEC DEVICE/FIXTURE >20 9.00 P.O. BOX 1504 VOICE (760) 777-7012 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: C/�— d Dater Applicant: Archit �ginpeer: '— Applicant's Mailing Address: Architect or Engineer's Address: Lic. No. BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of pedury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the. Business and Professionals Code, and my License is in full force and effect. License Class G 1 l ' License No. Date S 7 �i7 � � - Contractor OWNER-BUILDEk DECLARATION I hereby affirm under penalty of perjury that 1 am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do thework, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are.not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build'or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. —I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' corn gnsation insurance carrier and policy number are: /Cartier �% STAT -9 / IJ Policy Number _ - ` G I �62 &0 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so.as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall c�forthwith comply with those provisions. A�ZApplicant` WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. I. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and state that the above information Is correct. I agree to corn y and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county. to enter upoT4he abov tion ro r ins action purposes. or Agent) ate- _o Signature :(Applicant i w�r Page 2 Application Number 04-00003830 Date 5/04/04 Permit ... . . MECHANICAL Additional desc Permit 'Fee - 24.00 Plan Check Fee 6.00 Issue Date. . . . Valuation 0 Qty Unit Charge Per Extension BASE. FEE 15.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD. 9.00 Permit PLUMBING Additional desc Permit Fee 18:00 Plan Check Fee 4.50 Issue Date Valuation' 0 Qty Unit Charge, Per Extension BASE FEE. 15:00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 ------------------------------------------------------------------------------- Special Notes and'Comments 430 SQ. FT'. OFFICE / T.V. ROOM Other Fees ART IN PUBLIC PLACES -RES .00. ENERGY REVIEW FEE 16.38, STRONG MOTION (SMI) - RES. 27.45 Fee summary - Charged Paid Credited -Due' Permit Fee Total 333.05 .00 .00 333.05 Plan Check Total 184.06 .00 .00 184.06 Other Fee Total 18.83 .00 .00 18.83 Grand Total 53.5..94 00 .;00 535.94 4 X A X Biff# 5-L IV City of La Quinta 1 4/� % Building a Safety Division 1 P.O. Box 1504, 78-495 Calle Tampico 0 La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # 0�03 -qlq I/, Project Address: Owner's Name: A. P. Number: Address: t4 q 3 00 w YLi—o L,) . c - lCity, Legal Description: ST. Zip: , /+ 5-3 Contractor: ITelephone: Address: jectDescription: 33, 5— City, ST, Zip: 1P Telephone: State Li;. ck S IF 3 0 City Lic. #: Arch., Engr., Designer -re- Q!—A� VtZAEMI Cr Address: Address: 6- 33Y MA-&J,,M City, ST, Zip: Telephone: OT? 2 sir rConstruction Type: V - "Occupancy: - State Lie. #: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: D;,'+ -,$) a- K&A Sq. Ft.. # Stories: # Units: 0 . Telephone # of Contact Person: S rEstimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural C21CS. Reviewed. ready for corrections Plan Check Deposit Truss CACL Called Contact Person Plan Check Balance Energy Calts. Plans picked up ✓ Construction Flood plain plan Plans resubmitted Mechanical Grading plan T' Review. 5/3/01 "Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.NLE H.O.A. Approval Plans resubmitted Grad. -ng IN HOUSE:- Review, ready for correctionsrissut Developer Impact Fee Planning Approval Called Contact Person A.*I.P.P. Pub. Wks. Appr Dattof permit iss F School Fees f Na 11 , & Qp 6,4 I - Tot Permit F.. 4— Jr A.,%- [N, . LJ/1-11 1A t-1 X yal TANDY'S INSPECTION INC. PO BOX 13766 PALM DESERT, CA 92255 SPECIAL INSPECTION DAILY REPORT: oFFICE.'FAX 909.769.9717 PAGER 760.776.3339 DESCRIPTION OF WORK INSPECTED C,21 l4t Its t,2S�v� tom. S 3_ o °c.2 o a ad o ` at,-\ F. A5 01- o _ y"SUPPUER TYPE OF INSPECTION PERFORMED DATE PHYSICAL ADDRESS P'ERmR NuwER 0 q-3830 JOB NAME ^ UCTURE J ARCHITECT ENGINEER GENERAL CONWCiOR � � `dam -e SUBCONTRACTOR DESCRIPTION OF WORK INSPECTED C,21 l4t Its t,2S�v� tom. S 3_ o °c.2 o a ad o ` at,-\ F. A5 01- o I HEREBY CERTIFY THAT 1 HAVE MPECTEO ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED. AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING LAWS - cc: INSPECTORS SIGNA INSPECTORS CERTIF"TDN AGENCY AND NUMBER SAMPLE INFORMATION y"SUPPUER TICKET NUMBER MD( NUMBER 8 TM'- � AJR TEMP SAMP� SLUMP TIME IN MIXER LOCATION WELDING INFORMATION PROCESS WELDERS NAME CERTIFYING AGENCY AND CERTIFICATION NUMBER I HEREBY CERTIFY THAT 1 HAVE MPECTEO ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED. AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING LAWS - cc: INSPECTORS SIGNA INSPECTORS CERTIF"TDN AGENCY AND NUMBER TITLE 24 REPORT t 'T'itle 24 Report for: THE DEGEARE ADDITION �V 44310 Willow Circle -La Quinta, Ca 92253 Project Designer: DAVID DEGEARE 44310 Willow Circle La Quinta, Ca 92253 (760) 408-0972 Report Prepared By: R. Krown CEA R01-93-204 ; Desert Energy Services P.O. Box 621 Rancho Mirage, CA 92270-0621 (760) 564-2044 111119d Ener 0yl Analyst Rin d R PCro� 1 NR o rr - - r r R 98=83404-" CITY OF LA QUINTA E c.�" , or r� whg &ww cert . •. BUILDING &SAFETY DEPT Dumber: Ap P R0 EI® ' FOR 401 DATE BY , Dae ' 3/26/200,4;; The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 401 User Number. 2366 ': u A r TABLE OF CONTENTS A , ,fir! r .`Cover Page _ - - 1. Table of Contents 2, Form CF -1 R Certificate of Compliance 3 Form.MF-1 R Mandatory Measures Checklist e g Form C -21R Computer Method Summary g Form ENV -3 Proposed Construction Assembly 12 HVAC System Heating and Cooling Loads Summary °,13 f y a �. EnergyPro 3.1 By EnergySoft __ Job Number: 401 User Number. 2366 Certificate of Compliance: Residential_ (Part 1 of 2) CF -1 R THE DEGEARE ADDITION 3/26/2004 Project Tide Date 44310 Willow Circle La Quinta Project Adder Building Permit # Desert Energy Services (760) 564-2044 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 430.f? Average Ceiling Height: 9.0 ft Total Conditioned Slab Area: 430 f? Building Type: (check one or more) ® Single Family Detached ® Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition _. Front Orientation: (North) 0 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 0.24 Number of Stories: 1 ❑ Raised Floor Component Const. Frame Assembly Slab On Grade n/a 0.756 Tile/Att1c1R-38/Gyp Wood 0.026 R-13 Wall (W.13.2x4.16) Wood 0.088 Location/Comments (attic, garage, typical, etc.) Covered Slab w/R-0.0 Perimeter Insulation Exterior Roof Exterior Wall CCUCCTDATIr1N Shadinn DAvicas Type Orientation Area SF t r Fenestration SHQC Exterior Shading Overhang Side Fins Yes / No Yes / No Wight ht 8.0 0.80 0.43 None ❑ ® ❑ x❑ Left (Southeast) 4.0 0.38 0.29 Bug Screen x❑ ❑ ❑ X❑ Rear (South) 44.0 0.38 0.29 Bug Screen ❑ ® ❑ 191 Right (West) 40.0 0.38 0.24 Bug Screen ❑ X❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El 1-1 El Fl F1 1:1 ❑❑ ❑ ❑ ❑ ❑ 1:1 1:1 El Run InitWon Time* 03IMM 11 Run Codet 1080330211 EnerwPro 3.1 By EneMySoft User Number. 2366 Job Number. 401 Pa e:3 of 13 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R ' THE DEGEARE ADDITION 3/26/2004 Project Title Date • HVAC SYSTEMS Note: Input Hydronic or combined Hydronic data under Water Heating Systems, except Design Heating Load. - Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Ftimace 80% AFUE mets in Attic 4.2 Setback _ PART OF FLIRN/CLI-1 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location I heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER l Duds in Attic 42 Setback PART OF Ft IRNO 1-1 - WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External ` Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btuthr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. r 12r UTARKC COMPLIANCE STATEMENT' This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions code) Documentation Author Name: Name: R.Krown CEA Rol -93-204 Title/Firm: DAVID DEGEARE Title/Firm: Desert Enemy Services Address: 44310 Willow circle Address: P.O. Box 621 La Quinta. Ca 92253 Rancho Mirage, CA 92270-0621 Telephone: (760) 406-0972 Tel e: 0 564-2044 Lic. #: / ,- ",157 O (signs e) (date) ( gnature) (date) Enforcement Agency Name: Title/Firm: Address: TPlenhnnP• (signature/stamp) (date) Run Initiation Time: 03/2610411:43:31 Run Code: 1080330211 nergyPro 3.1 . By EnergySoft User Number. 2366 Job Number. 401 PageA of 13 Certificate of Compliance: Residential (Addendum) CF -1 R THE DEGEARE ADDITION 3/26/2004 Project Title -- Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the Items specified in this checklist These Items require special written justification and documentation, and special verification to be used with the performance approach. The local —fnr amant ananry Antarminast tho adanuacv of the lustification. and may resect a buildina or design that otherwise complies r r based on the adequacy of the special justification and documentation submitted. Plan Field The HVAC System 'PART OF FURN/CU-1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "PART OF FURN/CU-1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. r The HVAC System "PART OF FURN/CU-1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 0312610411:43:31 Run Code: 1080330211 :nerg^ 3.1 By EnergySoft User Number. 2366 Job Number. 401 Page:5 of 13 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lownse residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (7 may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whathar thou nra ehn wn al.¢awhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes, or enter NIA if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures © '9150(a): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ®'§150(c): not apply to exterior mass walls). §I50(d): Minimum R-13 raised floor insulation in framed floors or equivalent §150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no a greater than 2.0 pemtrnch. ® §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ®6116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §I50(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ §150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures E] 6110.13: HVAC equipment, water heaters, show erheads and faucets certified by the Commission. ® §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. 11500): Setback thermostat on all applicable heating and/or cooling systems. © §150(j): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number: 401 Page:6 of 13 ri i Mandatory Measures Checklist:_ Residential (Page 2 -of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures -4—thar thaw am nhnwn Pinawham in the documents or on this checklist only. 3.1 By EnergySoft User Number. 2366 Job Number: 401 Page:7 of 13 DESCRIPTION . Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) [X—] 150(m): Ductsand'Fans 1. Ali ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; duds insulated to a minimum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other dud -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of dud systems and their components shall not be sealed with doth back rubber adhesive dud tapes unless such tape is used In combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, dud board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Duds installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area d the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with doth back rubber adhesive dud tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot 2. System is Installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. + b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. ❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) El§118 (f): Cool Roof material meet specified criteria Lighting Measures ❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. El1150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternve s requ ati to thiirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation Dover) appro ved. 3.1 By EnergySoft User Number. 2366 Job Number: 401 Page:7 of 13 DESCRIPTION . Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) [X—] 150(m): Ductsand'Fans 1. Ali ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; duds insulated to a minimum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other dud -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of dud systems and their components shall not be sealed with doth back rubber adhesive dud tapes unless such tape is used In combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, dud board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Duds installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area d the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with doth back rubber adhesive dud tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot 2. System is Installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. + b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. ❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) El§118 (f): Cool Roof material meet specified criteria Lighting Measures ❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. El1150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternve s requ ati to thiirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation Dover) appro Computer ,Method Summary (Part 1 of 3) C -2R 11AF D [, ARE ADDITION 3/26/2004 Project TWO Date Quints Project Address Building Penna # D -PSP Fnemv Services —(760 5) 64-2044 Plan Check/Date Documentation A'I�iw `- Telephone i:mm[)uter Performance __ 15_ Feld Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.73 3.17 0.56 Space Cooling 39.30 38.50 0.80 Domestic Hot Water 0.00 0.00 0.00 Totals 43.04 41.67 1.36 Pan -ant honor than ctandnrel- 3.2% Total Conditioned Floor Area: 430 ft2 Floor Construction Type: ❑ Raised Floor X❑ Slab Floor Building Type: Single Fam Detached Building Front Orientation: (North) 0 deg Total Fenestration Area: 22.3% Number of Dwelling Units: 0.24 Total Conditioned Volume: 3,870 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 430 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type _Type Hgt. Area PART OF Ft IRNLCI 1-1 430 —3,87.0 _"4_ Conditioned— Setback— __n/ OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Location / Comments ADDITION ADDITION ADDITION ADDITION AnDITION EnerovPro 3.1 By EnerovSoft User Number. 2366 Job Number. 401 Page:8 of 13 1 Computer Method Summary (Part 2 of 3) C-2R THE DEGEARE ADDITION 3/26/2004 Pmjed Two Date FENESTRATION SURFACES U- Act. GI&ing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments $�ht Front (North) g 0 � Rnn n 43 —0- —0 BriStolite�dl9hts ADDITION -t- 2 Window Left (Southeast) 4.0 0.380 0.29 135 90 Hurd NonMtl Clear Low E2 ADDITION 3 Window Rear (South) 20.0 0.380 0.29 180 90 Hurd NonMtl Clear Low E2 ADDITION 4Window Rear (South) 24.0 0.380 0.29 180 90 Hurd NonMtl Clear Low E2 ADDITION 5 Window Right (West). 40.0 0.380 .0.24 270 90 Hurd NonMtl Clear Low E2 ADDITION i_. ;-< - INTERIOR AND EXTERIOR SHADING Window Overhang_ Left Fin Right Fin Exterior Shade Type SHGC Hgt. Wd. Len. Hgt: LExt_ RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 2 Bug Screen 0.76 4.0 1.0 2.0 0.1 2.0 2.0 3 Buts Screen 0.76 4 Bun Screen 0.76 9� Bug Screen 0.76 i` JV - .8 F: - e} - 'R 4 - Run InFtiadan Time• 03/261041143.31 Run Code: 1080330211 EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 401 Page:9 of 13 t ti . i Computer Method Summary (Part 3 of 3) C -2R THE DEGEARE ADDITION 3/26/2004 Project TWO Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation ` Type Length Factor R -Val Depth Location / Comments Slab Perimeter 5 0.76 0.0 0 ADDII N 2EMARKS HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPFxducts/attic, etc.) R -Value Type Comments Central Fumace 8096 AFUE Ducts in Attic 4.2 Setback PART OF FURN/CU-1 _ .Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. ' Cooling Equipment Minimum Duct r. Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments _ Split Air Conditioner 12.0 SEE B Ducts in Attic 4.2— Setback PART OF FURN/CU-1 a ]f^ WATER HEATING SYSTEMS, Rated' Tank Energy FaCO 1 Tank Insul. - Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. t For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. 2EMARKS Computer Method Summary (Addendum) C -2R THE DEGEARE ADDITION 3/26/2004 Project TWO - Date Special Features and Modeling Assumptions ,a The local enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach. The local nfo n t n determines the adequacy of the Justification and may reject a building or design that otherwise complies ercemeage _JFbased on the adequacy of the special justification and documentation submitted. Plan Field The HVAC System "PART OF FURN/CU-1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. " — -HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. _'Plan7 Field The HVAC System "PART OF FURN/CU-1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. y The HVAC System "PART OF FURN/CU-1" is using reduced dud leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. �Energypro 31 By Energysoft User Number. 2366 Job Number: 401 Page: 11 of 13 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 W DESCRIPTION OUTSIDE SURFACE AIR FILM W Roofing, Slate D N 3 Plywood � Air Space z O 6 SKETCH OF ASSEMBLY ASSEMBLY NAME DESCRIPTION OUTSIDE SURFACE AIR FILM 1 Roofing, Slate 2 Membrane, Vapor -Permeable Fell: 3 Plywood 4 Air Space 5 Insulation, Mineral Fiber, R-38 6 Gypsum or Plaster Board 7 0.450 8 Ceiling /Roof 9 FRAMING MATERIAL Wood INSIDE SURFACE AIR FILM ASSEMBLY NAME WALL WEIGHT (lbs/sf) CAVITY R -VALUE (Rc) (Tile/Attic/R-38/Gyp 0.170 ASSEMBLY 0.050 0.050 Floor 0.060 TYPE (check one) 0.620 0.800 Wall 38.000 11.385 0.450 x Ceiling /Roof 3.86 FRAMING MATERIAL Wood 2.08 FRAMING % 10 % Framing % 25.72 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) 7% (24" o.c. Floor/Coil.) R -VALUE WALL WEIGHT (lbs/sf) CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.050 0.050 0.060 0.060 0.620 0.620 0.800 12.375 38.000 11.385 0.450 0.450 1.42 3.86 0.36 1.39 2.08 0.26 0.610 0.610 25.72 SUBTOT 40.76 RC o�u *HEAT CAPACITY O tional WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) members. [ 0.0245 6.25 0.30 1.88 0.06 0.35 0.02 1.42 0.29 0.41 3.641 0.39 1.42 3.86 0.36 1.39 2.08 0.26 0.54 17.3 TOTAL HC 5.7 •NOTE: Weight and Specific Heat values for materials netrated by wood framing Include the effects of the framing members. [ 0.0245 x 0.90 ] + [ 0.0389 X 0.10 1 1 Rc 1 - (Fr96 / 100) 11 Rt Fr°/6 / 100 ASSEMBLY U -VALUE I EneravPro 3.1 By EnemvSoft User Number. 2366 Job Number: 401 Page: 12 of 13 1 HVAC SYSTEM HEATING AND COOLING LOADS. SUMMARY PROJECT NAME DATE THE DEGEARE ADDITION 3/26/2004 SYSTEM NAME FLOOR AREA PART OF FURN/CU-1 430 Number of Systems 1 Heating System Output per System 89,000 Total Output (Btuh) 89,000 Output (Btuh/sgft) 207.0 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 134.9 Total Output (sgftrron) 89.0 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cf nisgft) 4.65 Airflow (cfmrron) 413.8 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD CFM I Sensiblel Latent I I CFM I Sensible I 8,9261 8 0 BDP CO 395CAV060111/563CN060 44,106 4,419 89,000 Total Adjusted System Output 44,106 x,419 for (Adjusted for Peak Design Conditions) 00 TIME OF SYSTEM PEAK C Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heatina Peak 26.0 OF 69.8 OF 69.8 OF 111.6 OF ioh Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 111.50F 2000 cfm ROOMS 70.0 of 69.8 of l �% Return Air Ducts 4 DOLING SYSTEM PSYCHROMETRICS(Airstream Temperatures at Time of Cooling Peak 115.0/73.5OF 78.2/62.2OF 78.2/62.2OF 57.5/54.60F 01 OW O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 57.7 / 54.7 of 2000 cfm 40.9% R.H. ROOMS i 78.2/62.2 of 78.0 /62.2 of =Returnir Ducts � I EnemyPro 3.1 By EnemySoft User Number. 2366 Job Number. 401 Page: 13 of 13