Loading...
15178 (SFD)r '' j Q P.O. BOX 1504 N o . 15178 Building 78-495 CALLE TAMPICO Address 78-26r W?i' nbe_ Cove Cour`' LA OUINTA, CALIFORNIA 92253 Owner R.G" Williams Development Corp. Mailing TYPE CONST. '�""N OCC: GRP. R3 Mailing Address — £r k si­gniA 17n A.P. Number City Zip Tel. Legal Description .Lo 11 Tract 28010 Man 1.�-?3 Contractor Project Description wire as above Address .. City Zip Tel.: State Lic. City & Classif.. 443919 Lic. #"i& i Sq. Ft. No. No. Dw. Arch., Engr., Size 1286 Stories Units ' DesigneStffgro $12��$�� Newil] " Add ❑ Alter ElRepair ❑ Demolition ❑ Address Tel. 68-487 Palm` Canon Dr 32:8-1801 City Zip State _ ..�•. Z Lic. # . r• LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the,Business and Professions Code, and my license is in full force and--- . effect ;` -, t }''' r� � Fi -� t F SIGNATURE DATE OWNER -BUILDER DECLARATION Estimated Valuation I hereby affirm that 1 am exempt from the Contractors License Law for the following 78,953.00 reason: (Sec.. 7031:5,8ustriess and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also - requires the applicant for. such permit to file a signed statement that he is licensed pursuant to PERMIT AMOUNT " the provisions of the Contractor's license Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or, that. he is exempt therefrom, and the basis for the alleged exemption.. Any violation of Section 7031.5 by 'any- applicant for a permit Plan Chk.•Decp.. - subjects the applicant to a cfwl penalty of not more than rive hundred. dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will Plan Chk. Bal. 464.15 do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who Const.. - - builds or, improves thereon and who does such work himself or through his own employees, Mech. - '' '49.00 .. provided that such improvements are not intended or offered for sale. If, however, the building or Improvement is sold within one year of completion, the owner -builder will have the burden Electrical (� of proving that he did not Wild or improve for the purpose of sale.) 1- 0 I, as owner of the property, am exclusively contracting with licensed contractors to con- Plumbing-- 132.010 struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who Wilds or improves thereon, and who contracts for S.M.I.7.9111 such projects with a contractors) ficensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec B. l:• P.C. for this reason Grading 20 Driveway Enc. Date owner' Infrastructure 1.756.39 WORKERS' COMPENSATION DECLARATION ' I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensatibn Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. y''`P Company O Copy is filed with the city,. ❑ Certified copy is hereby furnished. TOTAL 3091 35 CERTIFICATE OF EXEMPTION FROM REMARKS WORKERS' COMPENSATION INSURANCE (This section need not be completed ff the permit is for one; hundred dollars ($100) va'uation or less.) • - I certify that in the performance of thg'work for which this permit is issued, I shall not • . - - employ any person in any manner'so as to become subject to the Workers' Compensation Laws of California Date Owner NOTICE TO APPLICANT: B, after making this Certificate of Exemption you should become ZONE: - BY: ' subject to the Workers' Compensation provisions of the " Labor Code, you must forthwith - comply with such provisions or this permit shall be deemed revoked. ;� ,. - Minimum Setback Distances: Front Setback from Center Line ( Rear Setback from Rear Prop. Line WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, ANDSlde Street Setback from"Ce ter Line SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO -ONE f//ti/ HUNDRED' THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, Side Setback from Property Line DAMAGES AS PROVIDED FOR IN SECTION 3708 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. n✓ This is a building permit when properly filled out, signed and validated, and is subject to FINAL DATE INSPECTOR expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information -is correct. Issued by: Date Permit I agree to comply with all city and county ordinances and state laws relating to building /� (y construction, and hereby authorize representatives -of this .city to enter the above-. L [� / mentioned property.for inspection purposes. Validated by: \ �9y`F Signature of applicant Date Mailing Address Validation: City, State, ZIP \, CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBIW%3 FEES 1ST FL. SQ. FT. $ UNITS COLL, AREA 2ND FL. SQ. FT. ROUGH PLUMB. BONDING YARD SPKLR SYSTEM POR. SQ. FT. ® MOBILEHOME SVC. BAR SINK GAR. SO. FT. ® POWER OUTLET ROOF DRAINS CAR P. SQ. FT. DUCTWORK DRAINAGE PIPING WALL SQ. FT. GAS (ROUGH) �/ METER LOOP T DRINKING FOUNTAIN SO. FT. ® HEATING (FINAL) URINAL ESTIMATED CONSTRUCTION VALUATION $ GAS (FINAL) TEMP. POLE WATER PIPING NOTE: Not to be used as property tax valuation FLOOR DRAIN MECHANICAL FEES WATER HEATER SERVICE WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASH ER(AUTO)(DISH) APPLIANCE DRYER WATER SYSTEM GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED GRADING cu. yd. plus x$ LAUNDRYTRAY AIR HANDLING UNIT CFM FINAL INSP. � KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SQ. FT. ®c BATH TUB FIRE ZONE ROOFING SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 11A c SEWAGE DISPOSAL SPARK ARRESTOR SQ.FT.GAR ® 3/ic HOUSE SEWER GAS PIPING PERMIT FEE ERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE FPL.CK.FEE!L CONST. FEE T. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK/ GROUND PLUMBIN NDERGROUND A.C. UNIT COLL, AREA SLAB GRADE G ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER R ROUGH WIRING DUCTWORK ROCK STORAGE FOUND. REINF. /1J GAS (ROUGH) �/ METER LOOP T HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL G !/Y!' GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM $ GRADING cu. yd. plus x$ =$ LUMBER GR. FINAL INSP. � FRAMING FINAL INSP. ROOFING 3 N 0//Oo7 i -y / REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATION/SOUND FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES/INITIALS GARDEN WALL FINAL ria Orr_?* Z u . 0 t - I t �1It.��tltN of 4 a Qu*nta �ilt� �S�I�P� �tkii�tult - This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. For .the following: BUILDING ADDRESS 78-265 Winter Cove Court Use Classification Single Family Dwelling Bldg. Permit No. 15178 Group R-3 Type Construction VN Fre Zone Use Zone R-3 Owner of Building E. G. Williams Development Address 42-600 Cook St. Su i t-,- 1 2(l Palm Desert, CA., 92211 City Daniel P. Crawford Jr. mow.. Dote March 11, 1996 Building Official POST IM A CONSPICUOUS PLACE r.' f •'.f I Fiber Glass Blankets when it (stalled according to the manufacturer's recom- mundations will provide the full rated thermal resistance value. blanket Insulation R Minimum Value _ Thickness -Iu obtain an: Installed if I:,ulation insulation rtatstance should (H) of: not be less than: R-38 _13 Thick' H-30 _ 91/4" Thick' R-26 83/4" Thick R-22 _ 71/2" Thick R-19 61/2" Thick' R-13 35'6" Thick" R-11 31/i' Thick 'Thickness varies, check bag label for producing locations 11 iickness. • • R-12.7 in a 31/2" cavity. Lot 1, Plan -11 S. - 2(oS lJ= ; nth La'&`Quinta, CA_ 92253 _7 1 -' Framing Correction for 40 Ib. Bag Rich -R Blowing Wool When installing in attics of new homes or existing homes where rto insulation is present, it is acceptable to adiust the This home is insulated with To seat the thermal resistance value (R), the manufacturer has specified the number of bags per: 2x8 2x6 1000 sq. ft. of net area that must be installed to meet both the minimum design thickness and I is 24.6. 24.8 minimum wt./sq. ft. requirements. Installing the correct number of gags/ 1000 sq. ft. necessary to meet the corresponding labeled resistance (R) value. (Based on 43 Ib. nominal net weight bag). ' i; ;.• , Rich -RT" Fiber Glass Blowing Wool Attic Insulation --40 Ib. Bag. ! i 2x4 Aveliage 25.1.; s. R Sags per Maximum Minimum Minimum Installed 2x8 Valuet 1000 sq. ft. Net Coverage Wt./ sq. ft. Thickness Thickness ++ I. To obtain The number of Contents The weight Installed Average 2x6 an insula- bags per 1000 of this bag per sq. ft.'of insulation installed I 19.8 �;". tion resis- sq. ft. of net should not installed insul- should thidu)efs, 2x4 tance area should not. cover ation should not not be will 20.1 •_::"'';. (R) of: be less than: more than: be less than: less than: ' typically be: 2x8 R-44 291/2 .34 sq. ft. 1.188 lbs. 15" Thick 161/2" 14.1 ,; , R-38 251/2 39 sq. ft. 1.029 lbs. 13" Thick 141/4" !; 2x6 R-30 201/2 49 sq. ft. 0.811 lbs. 1;01/4" Thick 111/4" I 14.3 i . R-22 15 I 67 sq. ft. 0.594 lbs. 71/2" Thick 81/4" 2x4 R-19 13 78 sq. ft. 0.514 lbs. 61/2" Thick 71/411 " 14.6 I R-11 71/2 135 sq. ft. 0.297 lbs. - 3-V4" Thick 41/411 !� Rich-Rlm Fiber Glass Blowing.Wool Sidewa)l,lnsulation-40_-Ib. Bag: !` R-16 161/2 60 sq. ft/ 0.667 lbs. ' 4" Thick 4" 2x8 R-14 15 66 sq. ft. 0.604 lbs. 35'er' Thick 3%0 1: 12.2 i,•=,.r,;..:.., R-14 141/2 68 sq. ft. 0.583 lbs. '31/2" Thick 31/z" 2x6 ,Average installed thickness is provided as a guide to installers. Actual thickness will vary . i 12.3 depending on conditions at the time of Installation. To obtain a specific R -value, linau 2x4 should not be applied over a Larger area than specified on the coverage chart i s 1 '12.6 I. Net wt./bag, minimum 37 lbs. This product conforms to the performance requirements of 2x8 Federal Specification HH -1-1030B. Type 1, Class B, and DOE FCS Standards. Also millets ., 7.1 Insulation Quality Standards of the State of California. 2x6 Fra(ping 16" on centerFraming 24" on center:" R Joists Ba4s per 1000 sq. ft. Valuest Dimensions (gross) `! R-44 2x8 2x6 2x4 28.2 28.5 28.9 Bags per 1000 sq. (gross) 28.6 ! I 28.8 29.1 cuveraye figures to compensate R-38 2x8 2x6 ! 24.2 i 24.5 24.6. 24.8 for the presence of the framing i; ;.• , (numbers as indicated in the 2x4 24.9 25.1.; s. following table. R-30 2x8 19.119.6 ++ I. 2x6 19.5 I 19.8 �;". 2x4 19.8 20.1 •_::"'';. R-22 2x8 1 . 13.6 14.1 ,; , 2x6 I 14.0 I 14.3 i . I H -values indicated obtained 2x4 14.3 14.6 I when properly4nstalled with pneumatic equipment. R-18 2x8 11.8 12.2 i,•=,.r,;..:.., 2x6 12.0 . i 12.3 1 I to higher the R -value, the 2x4 12.3 1 '12.6 I. greater the insulating power. R-11 2x8 6.8 7.1 Ask your seller for the fact sheet 2x6 6.8 7.1 on Fl -values. 2x4 6.8 7.1 Batts and rolls have been installed in conformance with the above Blowing wool has been installed in the ceiling or sidewall in con- recommendations to provide a thermal resistance value of formance with the above recommendations to provide an R-vl; R-... at inches in sq. ft. of ceilil tg, R- 13 at of R- using bags of this insulation to cover _._-- inches in 951 sq. ft. of exterior walls, and R- at square feet of er .t .,;.. ___ inches in sq. ft. of floors or crawls ace perimeter. i' minimum thickness of niches.. i ileSiggnnature ... p� t/C/(d=42r&AkJ24k) I Uate Signature Insulation contractor r 74-741 Joni Drive PALM DES&RT, CALIFORNIA 92260 H4, r;16 nes ! 1% 346-2339 Primed Residence .Address: Seasons Villas Lot Plan SSS -�f� I.LI n�P✓' Cb`!e, %�'. La Quinta, CA '92253 CERTIFlGTIO)V_ This is to certify that attic insulation has been installed in conformance with the coverage disc recommendations on the opposite side of this card using Ae bag{ to cover 123 0 sq. ft to obtain an//R--value of 30 Contractoes authodA signature l.!/t'Y a!YLGID) ej�1&4 Dares Installed br,. Builder. ROVER INSULATION 7&741 JONI 0 IVE PALM DESERT, CA 92260 i619) 3"-2339 p\ ''TH£ INsuATION SPECIALIST) IN R PRO PLUS (Formerly Cordex) STABILIZED INSULATION MANUFACTURED BY GREENSTONE INDUSTRIES Atlanta, Georgia • Elkwood, Virginia • Ft. Wayne, Indiana Norfolk, Nebraska • Phoenix, Arizona • Pbrtland, Oregon ATOMIZED PNEUMATIC APPLICATION COVERAGE CHART 3.5 .39.6 Net Coverage 758 R -Value at 5.5 No Adjustment for Trusses Gross Coverage 76'F Mean Minlrttwn Raca4 on 2 x ti Temperature Thickness Maximum Minimum Trusses on 16' Net Weight Per Centers Coverage Square Foot To Obtain Installed Square Minimum The Weight Per Suare Bags an Insulation Insulation Feet Bags Sq. Ft. of Feet Required Resistance Should Not Per Required Installed Per Per 1.000 .(R) of Be Less Than Bag Per 1,000 Insulation Should Bag Square Feet (inches) Square Feet Not Be Less Than: (lbs) - R-50 13.5 20.5 48.8 1.464- 21.3 46.9 R-42 11.4 24.4 41.0 1.230 25.6 39.1 R-40 10.8 25.6 39.0 1.172 26.9 37.2 R-38 10.3 27.0 37.1 1.113 28.4 34.1 35.2 R-32 8.6 32.0 34.1 .937 29.4 R-30 8.1 34.2 29.3 .878 36.5 27.4 R-24 6.5 42.7 23.4 .703 46.4 21.6 R-22 5.9 46.6 21.5 .644 51.0 19.5 R-19 5.1 53.9 18.5 .556 59.6 16.8 R-13 3.5 78.8 12.7 .381 87.0 11.5 R-11 3.0 93.2 10.7 .322 102.8 9.7 Sidewalls (pressure Filled -density 2.6 PPCF) R-13 (2 x4) 3.5 .39.6 25.3 758 R-20 (2 x 6) 5.5 25.2 39.7 1.192 Note: This coverage chart compensates for settling and is for estimating purposes only. - Stated R -Value is provided by installing the required number of bags per 1000 sq. ft: at a--- minimum installed thickness. Installation of the required number of bags may yield more than the specified minimum thickness and minimum weight per sq. ft. Actual coverage will be influenced by job conditions and application techniques, and may vary as much as 109'x, . without significantly affecting the stated R -Value. Failure of the installer to provide at least the required,number of bags per 1000 sq. ft. and at least the minimum thickness may result in a lower installed R -Value after settling. Compaction may occur during installations above R- 30 reauirina more than the stated number of bags to obtain the minimum installed thickness.