15178 (SFD)r '' j Q
P.O. BOX 1504 N o . 15178
Building 78-495 CALLE TAMPICO
Address 78-26r W?i' nbe_ Cove Cour`' LA OUINTA, CALIFORNIA 92253
Owner
R.G" Williams Development Corp.
Mailing TYPE CONST. '�""N OCC: GRP. R3
Mailing
Address — £r k signiA 17n A.P. Number
City Zip Tel.
Legal Description .Lo 11 Tract 28010 Man 1.�-?3
Contractor Project Description
wire as above
Address ..
City Zip Tel.:
State Lic. City
& Classif.. 443919 Lic. #"i& i Sq. Ft. No. No. Dw.
Arch., Engr., Size 1286 Stories Units
' DesigneStffgro
$12��$�� Newil] " Add ❑ Alter ElRepair ❑ Demolition ❑
Address Tel.
68-487 Palm` Canon Dr 32:8-1801
City Zip State _
..�•. Z Lic. # .
r•
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the,Business and Professions Code, and my license is in full force and---
. effect ;` -, t }''' r� � Fi -� t
F
SIGNATURE DATE
OWNER -BUILDER DECLARATION Estimated Valuation
I hereby affirm that 1 am exempt from the Contractors License Law for the following 78,953.00
reason: (Sec.. 7031:5,8ustriess and Professions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also -
requires the applicant for. such permit to file a signed statement that he is licensed pursuant to PERMIT AMOUNT "
the provisions of the Contractor's license Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or, that. he is exempt therefrom, and the basis
for the alleged exemption.. Any violation of Section 7031.5 by 'any- applicant for a permit Plan Chk.•Decp..
- subjects the applicant to a cfwl penalty of not more than rive hundred. dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will Plan Chk. Bal. 464.15
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who Const..
- -
builds or, improves thereon and who does such work himself or through his own employees, Mech. - '' '49.00 ..
provided that such improvements are not intended or offered for sale. If, however, the building
or Improvement is sold within one year of completion, the owner -builder will have the burden Electrical (�
of proving that he did not Wild or improve for the purpose of sale.) 1-
0 I, as owner of the property, am exclusively contracting with licensed contractors to con- Plumbing-- 132.010
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who Wilds or improves thereon, and who contracts for S.M.I.7.9111
such projects with a contractors) ficensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec B. l:• P.C. for this reason Grading 20
Driveway Enc.
Date owner' Infrastructure 1.756.39
WORKERS' COMPENSATION DECLARATION '
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensatibn Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. y''`P Company
O Copy is filed with the city,. ❑ Certified copy is hereby furnished.
TOTAL 3091 35
CERTIFICATE OF EXEMPTION FROM REMARKS
WORKERS' COMPENSATION INSURANCE
(This section need not be completed ff the permit is for one; hundred dollars ($100) va'uation
or less.) • -
I certify that in the performance of thg'work for which this permit is issued, I shall not • . - -
employ any person in any manner'so as to become subject to the Workers' Compensation
Laws of California
Date Owner
NOTICE TO APPLICANT: B, after making this Certificate of Exemption you should become ZONE: - BY: '
subject to the Workers' Compensation provisions of the " Labor Code, you must forthwith -
comply with such provisions or this permit shall be deemed revoked. ;� ,. - Minimum Setback Distances:
Front Setback from Center Line
( Rear Setback from Rear Prop. Line
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, ANDSlde Street Setback from"Ce ter Line
SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO -ONE f//ti/
HUNDRED' THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, Side Setback from Property Line
DAMAGES AS PROVIDED FOR IN SECTION 3708 OF THE LABOR CODE, INTEREST, AND
ATTORNEY'S FEES. n✓
This is a building permit when properly filled out, signed and validated, and is subject to FINAL DATE INSPECTOR
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information -is correct. Issued by: Date Permit
I agree to comply with all city and county ordinances and state laws relating to building /� (y
construction, and hereby authorize representatives -of this .city to enter the above-. L [� /
mentioned property.for inspection purposes. Validated by: \ �9y`F
Signature of applicant Date
Mailing Address Validation:
City, State, ZIP \,
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBIW%3 FEES
1ST FL. SQ. FT. $
UNITS
COLL, AREA
2ND FL. SQ. FT.
ROUGH PLUMB. BONDING
YARD SPKLR SYSTEM
POR. SQ. FT. ®
MOBILEHOME SVC.
BAR SINK
GAR. SO. FT. ®
POWER OUTLET
ROOF DRAINS
CAR P. SQ. FT.
DUCTWORK
DRAINAGE PIPING
WALL SQ. FT.
GAS (ROUGH) �/ METER LOOP
T
DRINKING FOUNTAIN
SO. FT. ®
HEATING (FINAL)
URINAL
ESTIMATED CONSTRUCTION VALUATION $
GAS (FINAL) TEMP. POLE
WATER PIPING
NOTE: Not to be used as property tax valuation
FLOOR DRAIN
MECHANICAL FEES
WATER HEATER SERVICE
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASH ER(AUTO)(DISH)
APPLIANCE DRYER
WATER SYSTEM
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
GRADING
cu. yd.
plus x$
LAUNDRYTRAY
AIR HANDLING UNIT CFM
FINAL INSP. �
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET'
COMPRESSOR HP
POLE, TEM/PERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER B.T.U.
SQ. FT. ®c
BATH TUB
FIRE ZONE ROOFING
SO. FT. ® c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SO. FT. RESID ® 11A c
SEWAGE DISPOSAL
SPARK ARRESTOR
SQ.FT.GAR ® 3/ic
HOUSE SEWER
GAS PIPING
PERMIT FEE
ERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE FPL.CK.FEE!L
CONST. FEE T. FEE
SMI FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK/
GROUND PLUMBIN NDERGROUND
A.C. UNIT
COLL, AREA
SLAB GRADE G
ROUGH PLUMB. BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS
SEWER R ROUGH WIRING
DUCTWORK
ROCK STORAGE
FOUND. REINF. /1J
GAS (ROUGH) �/ METER LOOP
T
HEATING (FINAL)
OTHER APPJEOUIP.
REINF. STEEL G !/Y!'
GAS (FINAL) TEMP. POLE
GROUT
WATER HEATER SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
$
GRADING
cu. yd.
plus x$
=$
LUMBER GR.
FINAL INSP. �
FRAMING
FINAL INSP.
ROOFING 3
N 0//Oo7 i -y
/
REMARKS:
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING
MESH
INSULATION/SOUND
FINISH GRADING
FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURES/INITIALS
GARDEN WALL FINAL
ria
Orr_?*
Z u .
0 t - I t
�1It.��tltN of 4 a Qu*nta
�ilt� �S�I�P� �tkii�tult -
This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building
Code certifying that at the time of issuance this structure was in compliance with the various
ordinances of the City regulating building construction or use. For .the following:
BUILDING ADDRESS 78-265 Winter Cove Court
Use Classification Single Family Dwelling Bldg. Permit No. 15178
Group R-3 Type Construction VN Fre Zone Use Zone R-3
Owner of Building E. G. Williams Development Address 42-600 Cook St. Su i t-,- 1 2(l
Palm Desert, CA., 92211
City Daniel P. Crawford Jr.
mow..
Dote March 11, 1996
Building Official
POST IM A CONSPICUOUS PLACE
r.'
f
•'.f
I
Fiber Glass Blankets when
it (stalled according to the
manufacturer's recom-
mundations will provide the full
rated thermal resistance value.
blanket Insulation
R Minimum
Value _ Thickness
-Iu obtain an: Installed
if I:,ulation insulation
rtatstance should
(H) of: not be less than:
R-38 _13 Thick'
H-30 _ 91/4" Thick'
R-26 83/4" Thick
R-22 _ 71/2" Thick
R-19 61/2" Thick'
R-13 35'6" Thick"
R-11 31/i' Thick
'Thickness varies, check bag
label for producing locations
11 iickness.
• • R-12.7 in a 31/2" cavity.
Lot 1, Plan -11
S. - 2(oS lJ= ; nth
La'&`Quinta, CA_ 92253 _7
1 -'
Framing Correction for 40 Ib.
Bag Rich -R Blowing Wool
When installing in attics of new
homes or existing homes where
rto insulation is present, it is
acceptable to adiust the
This home is insulated with
To seat the thermal resistance value (R), the manufacturer has specified the number of bags per:
2x8
2x6
1000 sq. ft. of net area that must be installed to meet both the minimum design thickness and I
is
24.6.
24.8
minimum wt./sq. ft. requirements. Installing the correct number of gags/ 1000 sq. ft. necessary to
meet the corresponding labeled resistance (R) value. (Based on 43 Ib. nominal net weight bag). '
i; ;.• ,
Rich -RT" Fiber Glass Blowing Wool Attic Insulation --40 Ib. Bag. ! i
2x4
Aveliage
25.1.; s.
R Sags per Maximum Minimum Minimum Installed
2x8
Valuet 1000 sq. ft. Net Coverage Wt./ sq. ft. Thickness Thickness
++ I.
To obtain The number of Contents The weight Installed Average
2x6
an insula- bags per 1000 of this bag per sq. ft.'of insulation installed
I 19.8
�;".
tion resis- sq. ft. of net should not installed insul- should thidu)efs,
2x4
tance area should not. cover ation should not not be will
20.1 •_::"'';.
(R) of: be less than: more than: be less than: less than: ' typically be:
2x8
R-44 291/2 .34 sq. ft. 1.188 lbs. 15" Thick 161/2"
14.1 ,; ,
R-38 251/2 39 sq. ft. 1.029 lbs. 13" Thick 141/4" !;
2x6
R-30 201/2 49 sq. ft. 0.811 lbs. 1;01/4" Thick 111/4"
I 14.3 i .
R-22 15 I 67 sq. ft. 0.594 lbs. 71/2" Thick 81/4"
2x4
R-19 13 78 sq. ft. 0.514 lbs. 61/2" Thick 71/411 "
14.6 I
R-11 71/2 135 sq. ft. 0.297 lbs. - 3-V4" Thick 41/411 !�
Rich-Rlm Fiber Glass Blowing.Wool Sidewa)l,lnsulation-40_-Ib. Bag: !`
R-16 161/2 60 sq. ft/ 0.667 lbs. ' 4" Thick 4"
2x8
R-14 15 66 sq. ft. 0.604 lbs. 35'er' Thick 3%0 1:
12.2 i,•=,.r,;..:..,
R-14 141/2 68 sq. ft. 0.583 lbs. '31/2" Thick 31/z"
2x6
,Average installed thickness is provided as a guide to installers. Actual thickness will vary
. i 12.3
depending on conditions at the time of Installation. To obtain a specific R -value, linau
2x4
should not be applied over a Larger area than specified on the coverage chart i s
1 '12.6 I.
Net wt./bag, minimum 37 lbs. This product conforms to the performance requirements of
2x8
Federal Specification HH -1-1030B. Type 1, Class B, and DOE FCS Standards. Also millets .,
7.1
Insulation Quality Standards of the State of California.
2x6
Fra(ping 16" on centerFraming 24" on center:"
R Joists Ba4s per 1000 sq. ft.
Valuest Dimensions (gross) `!
R-44
2x8
2x6
2x4
28.2
28.5
28.9
Bags per 1000 sq.
(gross)
28.6 ! I
28.8
29.1
cuveraye figures to compensate R-38
2x8
2x6
! 24.2
i 24.5
24.6.
24.8
for the presence of the framing
i; ;.• ,
(numbers as indicated in the
2x4
24.9
25.1.; s.
following table. R-30
2x8
19.119.6
++ I.
2x6
19.5
I 19.8
�;".
2x4
19.8
20.1 •_::"'';.
R-22
2x8
1 . 13.6
14.1 ,; ,
2x6
I 14.0
I 14.3 i .
I H -values indicated obtained
2x4
14.3
14.6 I
when properly4nstalled with
pneumatic equipment. R-18
2x8
11.8
12.2 i,•=,.r,;..:..,
2x6
12.0
. i 12.3
1 I to higher the R -value, the
2x4
12.3
1 '12.6 I.
greater the insulating power. R-11
2x8
6.8
7.1
Ask your seller for the fact sheet
2x6
6.8
7.1
on Fl -values.
2x4
6.8
7.1
Batts and rolls have been installed in conformance with the above
Blowing wool has been installed in the ceiling or sidewall in con-
recommendations to provide a thermal resistance value of
formance with the above recommendations to provide an R-vl;
R-... at inches in sq. ft. of ceilil tg, R- 13
at
of R- using
bags of this insulation to cover
_._-- inches in 951 sq. ft. of exterior walls, and R-
at
square feet of er
.t .,;..
___ inches in sq. ft. of floors or crawls ace perimeter.
i' minimum thickness
of niches..
i ileSiggnnature
...
p�
t/C/(d=42r&AkJ24k)
I
Uate Signature
Insulation contractor
r
74-741 Joni Drive
PALM DES&RT, CALIFORNIA 92260
H4, r;16 nes
!
1% 346-2339 Primed
Residence .Address: Seasons Villas Lot Plan
SSS -�f� I.LI n�P✓' Cb`!e, %�'. La Quinta, CA '92253
CERTIFlGTIO)V_ This is to certify that attic insulation has been installed in conformance with
the coverage disc recommendations on the opposite side of this card using Ae bag{ to
cover 123 0 sq. ft to obtain an//R--value of 30
Contractoes authodA signature l.!/t'Y a!YLGID) ej�1&4
Dares
Installed br,. Builder.
ROVER INSULATION
7&741 JONI 0 IVE
PALM DESERT, CA 92260
i619) 3"-2339
p\ ''TH£ INsuATION SPECIALIST)
IN
R PRO PLUS
(Formerly Cordex)
STABILIZED INSULATION
MANUFACTURED BY
GREENSTONE INDUSTRIES
Atlanta, Georgia • Elkwood, Virginia • Ft. Wayne, Indiana
Norfolk, Nebraska • Phoenix, Arizona • Pbrtland, Oregon
ATOMIZED PNEUMATIC APPLICATION COVERAGE CHART
3.5
.39.6
Net Coverage
758
R -Value at
5.5
No Adjustment for Trusses
Gross Coverage
76'F Mean
Minlrttwn
Raca4 on 2 x ti
Temperature
Thickness
Maximum Minimum
Trusses on 16'
Net Weight Per
Centers
Coverage Square Foot
To Obtain
Installed
Square
Minimum
The Weight Per
Suare
Bags
an Insulation
Insulation
Feet
Bags
Sq. Ft. of
Feet
Required
Resistance
Should Not
Per
Required
Installed
Per
Per 1.000
.(R) of
Be Less Than
Bag
Per 1,000
Insulation Should
Bag
Square Feet
(inches)
Square Feet
Not Be Less
Than: (lbs)
-
R-50
13.5
20.5
48.8
1.464-
21.3
46.9
R-42
11.4
24.4
41.0
1.230
25.6
39.1
R-40
10.8
25.6
39.0
1.172
26.9
37.2
R-38
10.3
27.0
37.1
1.113
28.4
34.1
35.2
R-32
8.6
32.0
34.1
.937
29.4
R-30
8.1
34.2
29.3
.878
36.5
27.4
R-24
6.5
42.7
23.4
.703
46.4
21.6
R-22
5.9
46.6
21.5
.644
51.0
19.5
R-19
5.1
53.9
18.5
.556
59.6
16.8
R-13
3.5
78.8
12.7
.381
87.0
11.5
R-11
3.0
93.2
10.7
.322
102.8
9.7
Sidewalls (pressure Filled -density 2.6 PPCF)
R-13 (2 x4)
3.5
.39.6
25.3
758
R-20 (2 x 6)
5.5
25.2
39.7
1.192
Note: This coverage chart compensates for settling and is for estimating purposes only.
- Stated R -Value is provided by installing the required number of bags per 1000 sq. ft: at a---
minimum installed thickness. Installation of the required number of bags may yield more
than the specified minimum thickness and minimum weight per sq. ft. Actual coverage will
be influenced by job conditions and application techniques, and may vary as much as 109'x, .
without significantly affecting the stated R -Value. Failure of the installer to provide at least
the required,number of bags per 1000 sq. ft. and at least the minimum thickness may result
in a lower installed R -Value after settling. Compaction may occur during installations above R-
30 reauirina more than the stated number of bags to obtain the minimum installed thickness.