Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
15185 (SFD)
P.O. BOX 1504 No. 15185 Building 78-495 CALLE TAMPICO. FORNIA 922 5 Contractor ress 3 Address '78- 305 Winter Co%70- Court LA QUI Owner E.G. srlilliams Development Corp. Mailing Address 42- 600 Cook ,Ste Suite 220 City Zip Tel. .Palm Desert' 92211 341-6880 NTA, CALI City Zip Tel.: State Lic. City & Classif.. 493919 Lic. # 1231 . Arch., Engr., • Designer stoffgren Fuller Asset.. Address Tel. .68-487 14.' .,Palm- Canyon, €3r . 328.1801 City Zip State Cat adtrad `cit 92262 Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that l am licensed under provisions of Chapter 9 (commencing with Section 7000) of- Division 3 of.the.Business and Professions Code, and my license'is in full -force and" effect.. "t .I , , .• f %•rf. si°t I-+rL L , e� E SIGNATURE - DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for.the following • reason: (Sec. 7031.5,Business and Professions Code: Any city .or county which requires a Permit to construct: alter, .improve, demolish, or repair any structure, prior to its issuance also requires the applicant for.such-permil to the a signed statement that he is licensed' pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with, Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit. subjects the applicant to a civil penalty of not more than rive hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec: 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements' are not intended or offered for. sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not bulld or improve for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to•con- struct the project. (Sec. 7044, Business andProfessions Code: The Contractor's License Law does not apply to an owner of propertywhobuilds or improves thereon, and who contracts for such projects with a contractors) #tensed pursuant to the Contractor's License Law.) - ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) . Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. . CERTIFICATE OF EXEMPTION FROM WORKERS'COMPENSATIONINSURANCE (This section need not be, completed it the permit. is for one hundred dollars ($100) vaNation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California Date Owner NOTICE TO APPLICANT: ff, after - making this Certificate of Exemption you should become subjectto the Workers' ' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. ' WARNING: FAILURE To SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL: AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. This is'a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days.' 1 certify that I have read this, application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives .of this city to enter the above-. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip r BUILDING: -TYPE CONST. 'wN' OCC: GRP.- R3 A.P. Number Legal Description Lot IS.Tract 28019 Plan 2^ -AR Project Description Sq. Ft. No. = No. Dw Size 137-1 Stories -Units Newla© Add ❑' ,• Alter ❑ Repair ❑ Estimated Valuation " .482-',r 677. 0 PERMIT '.. AMOUNT Plan Chk. Dep. ' Plan'Chk. Bal. 477..77 Const:. .. — . .553.00 49.00 Electrical _ Plumbing 132.06 S.M.I. A .. 7 Grading 20-00 Driveway Enc. Infrastructure 1860.24 TOTAL .'i REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop.,6ne Side Street Setback from Center Line Side Setback from Propertye Line FINAL DATE INSPECTOR Issued by: Datez, PermitV Validated by: \� .Validation: \\ CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBINU FEES 1ST FL. SQ. FT. @ $ UNITS COLL. AREA 2ND FL. SO. FT. ROUGH PLUMB. YARD SPKLR SYSTEM POR SO FT @ MOBILEHOME SVC. BAR SINK GAR. SO. FT. @ POWER OUTLET ROOF DRAINS CARP. SO. FT. DUCT WORK DRAINAGE PIPING WALL SO. FT. GAS (ROUGH) DRINKING FOUNTAIN SO. FT. @ HEATING (FINAL) URINAL ESTIMATED CONSTRUCTION VALUATION $ GAS (FINAL) WATER PIPING NOTE: Not to be used as property tax valuation FLOOR DRAIN MECHANICAL FEES WATER HEATER WATER SOFTENER VENT SYSTEM FAN EVAP.000L HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER WATER SYSTEM GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED GRADING yd. $ plus x$ LAUNDRY TRAY AIR HANDLING UNIT CFM FINAL INSP. KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. @ c BATH TUB SO. FT. @ c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID @ 11A c SEWAGE DISPOSAL SO.FT.GAR @ 3/.c HOUSE SEWER GAR. FIREWALL GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT.FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK S� GROUND PLUMBI� UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE G ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS#�� SE OR SE11 ! ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. 61 I1 GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEQUIP. REINF. STEEL d GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING yd. $ plus x$ _$ LUMBER GR. FINAL INSP. FRAMING Q 3 FINAL INSP. ROOFING /A �r C/!�• ✓tq REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING 8 d gs MESH INSULATIONISOUND14 FINISH GRADING FINAL INSPECTION10 CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES71NiT1ALS GARDEN WALL FINAL Fiber Glass Blankets when / ii i6talled according to the ii factuoer's mendations will provide the full rated thermal value. ° |^ ulanketInsulation !`' ' A Minimum Mmimum ` Value Thickness I u obtain Installed ..`u|auun ' insulation /"tiislancm should (R/u/: no/bm!esuUhan: ------' -'--'--------' n'38 13''Thiu�` � R-30 g xk*^ --------------------' H-26 8+*^'Tmox R-22 71m`Tmok A-1 9 61i2~Txick *' 35/e .'.. 31i?Thick _ ^Th ickneaa varies, check baglabel for producing locations . ^ This home is insulated with �� T,-, meet the thermal resistance'value (R), the manufacturer has specified the number of bags Filer 1000 sq. ft. of net area that must be installed to meet both the minimum design thickness and minimum wt./sq. ft. requirements. Installing the correut number o: bags/ 1000 sq. ft. is necessar y to meet the carresponding,labeleo resistance (R) value. (Based on 40 lb. nominal not weight bag). Flich-RI A Fiber Glass Blowinq Wool Attic Insulation -Q lb. Bea. i i!. ! 'Average FraMing 16" on center, Framing 24" on cenW.- -Bagsper Maximum Minimum Minimum installed Valuet 1000 sq. ft. Net Coverage Wt./ sq. ft. Thickness ThIckne" To obtain The number of i Contents The weight Installed Average an insula- bags per 1000 of this bag per sq. ft.'of insulation installed tion resis- sq. ft. of net should not installed insui- should thickn�ss tance area should not cover ation should n#X not be will 1: (R) of: belessthan: more than: be less than:' less than: typic* be: 28.9 29.1 coverage figures to compensate R -3a 2x8. 1 24.2 24.6 fur the presence of the framing 2x6 24.5 24.8 I I )UMbers as indicate in the 2x4 24.9 25.1 ,d following table. R-30 2x8 19.1 19.6 Flich-R Tm Fiber Glass BloyAnq Wool.Side%�#Il Insulation -4043. Bag. 2x6 19.5 19.8 77. 19.8 20.1 X R-22 2x8 13.6 14.1 AverageR ' depending on conditions at the time of installation. To obtain a specific R -value, lnl�u 14.0 14.3 should not be applied over a larger area than specified on the coverage charL when properlq installed with Net wt./bag, minimum 37 lbs. This product conforms to the performance requirements of Federal Specification HH -1-1030B. Type 1, Class 8, and DOE RCS Standards. Also meg Insulation Quality Standards of the State of California. 2x8 11.8 Framing Correction for 40 lb. FraMing 16" on center, Framing 24" on cenW.- Bag Rich -R Blowing Wool R Joists Baig's per 1000 sq. tL Bags per 1000 sq.X Valuest Dimensions (gross) (gross) 'When installing in attics of new R-44 2x8 28.2 28.6 J t,iomes or existing homes where 28.5 28.8 i io insulation is present, it is acceptable to adjust the 2x4 28.9 29.1 coverage figures to compensate R -3a 2x8. 1 24.2 24.6 fur the presence of the framing 2x6 24.5 24.8 I I )UMbers as indicate in the 2x4 24.9 25.1 ,d following table. R-30 2x8 19.1 19.6 2x6 19.5 19.8 2x4 19.8 20.1 X R-22 2x8 13.6 14.1 i R -values indicated obtained 2x6 2x4 14.0 14.3 14.3 14.6 when properlq installed with pneumabc equipmInt. R-19 2x8 11.8 12.2. 12.0 T1 ie higher the R-valu'e, the 12.3 12.6 greater the insulating power. R-11 2x8 6.8 7.1 A,,k your seller for th? fact sheet 2x6 i on R -values. 2x4 6.8 7.1 B,Alts and rolls have been installed in conformance with the above Blowing wool has been installed in the ceiling or sidewall in c9n recommendafions to provide a thermal resistance value of formance with ft above reoornmendabons to provid an Fi-v, - inches in - sq. ft. of ceiling. Fl- i,. of R-_ using - bags of this insulafian to cover --inchesin 770 sq. ft. of exterior walls, :2 R-- at square few of area 414 inches in sq. ft. of floors or crawl space perimeter. minimum thickness of krJies. SA 74-741 Jo ni Drive PALM DE�49T. CALIFORNIA 92260 'I'liolb 7186 IQ) 346-2339 pmtw Inv* / Residence Address: Seasons Villas Lot Plan 2 ]�-3bS U)Aey-Cine (I.- La Quintan CA 92253 CERTIFICAT10B4- This is to certify that attic insulation has been installed in conformance with the coverage chart recommendations on the opposite side of this card using 39 _ bajp to cover 133 sq. k to.obtain an R -value of 30 C`� Contmctoes authorized signature A06 �i1lA,ly Data Installedb2, Builder: ROVER INSULATION 74.741 1ON1 DRIVE PALM DESERT, CA 92260 (619) 346-2339�- THE INStAATION SPECIALIST) R -PRO PLUS (Formerly Cordex) STABILIZED INSULATION MANUFACTURED BY GREENSTONE INDUSTRIES Atlanta, Georgia - Elkwood, Virginia - Ft. Wayne, Indiana Norfolk, Nebraska - Phoenix, Arizona - Portland. Oreeon ATOMIZED PNEUMATIC APPLICATION COVERAGE CHART. 3.5 39.6 Net Coverage .758 R -Value at 5.5 No Adjustment for Trusses Gross Coverage 75'F Mean wn hated on 2 i 6" Maximum Minimum Temperature Thickness Trusses on 16* NO Weight Per Centers Coverage Square Foot To Obtain Installed Square Minimum The Weight Per Suare Bags an Insulation Insulation Feet Bags Sq. Ft. of Feet Required Resistance Should Not Per Required Installed Per Per 1.000 (R) of Be Less Than Bag Pert ,000' Insulation Should Bag Square Feet (inches) Square Feet Not Be Less Than: (Ibs) R-50 13.5 20.5 48.8 1.464 21.3 46.9 R-42 11.4 24.4 41.0 1.230 25.6 39.1 R-40 10.8 25.6 39.0 1.172 26.9 37.2 R-38 10.3 27.0 37.1 1.113 28.1 35.2 29.4 R-32 8.6 32.0 34.1 .937 34.1 R-30 8.1 34.2 29.3 .878 36.5 27.4 R-24 6.5 42.7 23.4. .703 46.4 21.6 R-22 5.9 46.6 21.5 .644 51.0 19.5 R-19 5.1 53.9 18.5 .556 59.6 16.8 R-13 3.5 78.8 12.7 .381 87.0 11.5 R-11 3.0 93.2 10.7 .322 102.8 1 9.7 Sidewalls (pressure Filled -density 2.6 PPCF) R-13 (2 x4) 3.5 39.6 25.3 .758 R-20 (2 x 6) 5.5 25.2 39.7 1.192 Note: This coverage chart compensates for settling and is for estimating purposes only. Stated R -Value is provided by installing the- required number of -bags -per 1000 sq: ft. at minimum installed thickness. Installation of the required number of bags may yield more than the specified minimum thickness and minimum weight per sq. ft. Actual coverage will be influenced by job conditions and application techniques, and may vary as much as 10% without significantly affecting the stated R -Value. Failure of the installer to provide at least the required number of bags per 1000 sq. ft. and at least the minimum thickness may result in a lower installed R -Value after settling. Compaction may occur during installations above R- 30 recuirira ^lore than the sta'.ed .^.umber of bags to obtain the minimum installed thickness. r IL .�Jz OF �t� II� �� LItYi��t .. • j This Certificate, issued pursuant to the requirements of Section 306 of the Uniform Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating. building- construction or use. For the following: Y BUILDING ADDRESS 78-305 Winter -Cove Court . Single Family Dwelling. Bldg. Permit No. 15185 'Use Classification. j 9• Group R3 Type Construction VN Fre Zone Use Zone R3 Owner of BuildingE.G. Williams Development Address 42-600 Cook "St. Suite 120 Palm Desert, CA., 92211 City Daniel P. Crawford Jr. Dote October 13, 1995 Building Official POST'IM A OON!?ICUOU! PLACE I is it � !I