Loading...
0403-029 (SFD)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chanter 9 (commencing with Section 7000) of Division 3 of the Business and `P,rofhsionals Code, and my License is in full force and effect. License# �pLic..Class Exp. Date 12� •0 f« J'1 {7'f wl I 5 ai n ijy7 Date ;'� f 7 Signature of Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from.the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively 'contracting .with licensed contractors to construct the ;project (Sec. 7044, Business & Professionals Code). () I am exempt under Section B&P.C. for.this reason Date Y `/ Signature of Owner ! WORKER'S COMPENSATION CLARATION I hereby affirm under penalty of. perjury one of. the following, declarations: () I have and will maintain a certificate of consent to self -insure for workers' Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work foi which this permit is issued. ' ( ) I have and will maintain workers'• compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier. S'T1 I,Z, pUtID Policy No. 1€88263-02 (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the.performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become —subject to the workers' compensation provisions of Section 3700 of the Labor Code; I shall forthwith comply with those provisions. t Date:y ,_ ..•✓ Applicant Warning: Failure to .secure Workers' Compensation coverage is unlawful and Shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section -3706 of the Labor Code, interest and attorney's fees. .... r IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes. Signature (Owner/Agent) f; 114- - Date BUILDING PERMIT PERMITk . ,. . DATE r VALUATION 291 415ei .60 LOT 48. TRACT 2899 IJOB SITE ADD RESS •. .o-;�.v:-tTT.iutl ai •11: ��1' ~� . APN r�7!5 a^�rY.2T OWNER CONTRACTOR/DESIGNER/EN (NEER C.RV. j..A+4li.yzE"1'A7o is 2 l0 , ir+J t l3 61 1! Risk:, .1 Cao 100 1' . WAZMp'1°ON AVE. 4) 00 ESCONDIDO CA 92025 IMCNOWUIDO (,:A 92025 (m)839-8238 C.KA 5415 USE OF PERMIT 0.401Z FAMILY D'tiV" , G- . SW e - li )`f 44 #LAN DOES 140T MCL.'UDE ttl..t.1C:K `NN -l's, POOL O.P A O`t1. DRAiF_I'y Y A OPM;AC::K 71'36 RED1a<THON t`C7 MAN CHECK lirEI: WE TO MULTIPLE ISSUANCE OF 5:�3 , 9 PLAN TYPE CUSTOM C-611d'I'i&.1JCTIO_N :MtH.00 S.F PORCHIPA.9'IU4 748.08. SP I1A A-C#VCARPt?RT 660.00 SF 1 S17MAI 73 C0.Vr OF COMMUCnow 294.5109M C0. TRU0.TION F.M 101 X000.418.000 $1,32no PLAN CHECK FRE 101-000.439-.318 $260.62 WCH ANICAL M 101-000-421-000 $143,60 TLa,1'R.ICAL. FEEP, 101-000-420-000 $210.2's - Pt'UMOTHO MOR 101.000-419.000 .STFLONO MOTION PEZ • R'PSIO 103 -040-no4 1-000 �L9.44 0HAI9ING A;d _01 -000 3J$.,Do AR'C INPUBLIC UBLIC PLACU - RE, SIC 270-000-445-000 $236130 E.IU t••'1MAL tw[ NSTR7 0,17 1014 MD PxtlC4RC ; X1,810. � UIe�6yy=P .tiUS X611 � p&A KRIM;FES DUE now MAR 18 2004 11 CITY OF LA QUINTE2 RECEIPTB,✓ -7:1, ` �� FINAL DAT/E2 INSPEC O T 6 1, c; 0 . 7 INSPECTION RECORD OPERATION DATE-. INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs erground Ducts _ Forms & FootingsDucts Slab Grade Return Air Steel _Combustion Roof Deck ' O.K. to Wrap Air Exhaust Fans F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath 3 Final Final BLOCKWALL A PROVALS POOLS - SPAS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test 76 Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) Q COMMENTS: 07/01/2004 12:03 760-743-3109 SCHMIT ENGINEERING PAGE 02/03 Schmit Engineering Structural Design To: The City of La Quinta Building Inspection Department Date: July 1, 2004 Re: Eagle Bend @ PGA West, Plans #1, & #2 Innovative )Resort Communiti s Plan Check No.: 0305-053 This letter is in regards to the above referenced project. As requested, on J aly 1, 2304, as the engineer of record, :..made a site structural inspection for Phase VI. My inspection included one each of the floor plan types: Plan #1A lot 444, and Plan 42C lot Al. The following is a list cfmy findings. Plan ;#1: 1. Provide 2x blk'g and A35 shear -transfer clips above beams at front o.'� garage, in line with steel columns. Blocking is offset above beams. 2. Check to verify drag straps are installed in the following locations per pan, at the end3 ofthe 5.25 x 16 t earn above covered patio"at back of house, and at back patio to ho<ase strap ties (LSTA-24). MSTI48 from 6x10 cantilevered beam to "K" shear wall between the Casita B -.droom and Casita Lounge. LSTA-24 from girder truss to wall above ,zecondary master bedroom to exterior wall of walk -.n closet. 3. At'.edger to wah connection at left side of entry wall verify 5-16d nail,i min. each stud. 5. Verify t1tat at all interior shear wall locations that tie A35 shear transfe- clips have been installed, between the block and top plates as shown in details 16/A11.3, 3/A11.3, 12/Al 1.3; etc. 6. No opening was framed in wall facing courtyard at walk-in closet off of Casita Bedroom. 7. Tightened down all anchor bolt nuts and verify that at all sill plate breaks that an anchor bolt is install -,d per standard sill plate anchorage detail Plan 42: " 1. ShE ar transfer claps appear to be missing above the 5.25 x 14 P.L. bear, i at front of garage in line with z teel columns. 2. Check to verify drag straps are installed in the following location per ply n, from the header to "R" type s'aear panel's at the rear of the house offgather:ng room. 3. Extend the "I" type shear panel to front of garage at the left side of garage near entry gate. CO 1965 Rohn Road, Escondido, CA 92025 ('1060) 743-0592 07/01/2004 12:03 760-743-3109 S--HMIT ENGINEERING PAGE, 03/03 4. See item 45 above for plan #1. 5. See :item 47 above for plan 41: 5 x 11.78 to 6x12 beam. Existing hanger appears to be wrong 6. Check hammer at rear patio from 5.2 type ar d also installed incorrectly. 7. Three holdowns appear to be missiung at the shear wall between the Casita Bath and Casita Bedroom. If you should have any questions regarding this letter, or need any further clarification, please do not hesitat-, to call me. Sincerely, X pFESS/ Q� nhq s. scr,�✓��� John Schmit R.CT1. #35417 No.ssatT ae Y/? XY4 CAtt��� r