9611-023 (RER)LICENSED dONTRACTOR DECLARATION
I hereby affirm, undeP penalty of perjury that I am licensed under provisions of
Chapter 9 (co6mencing:with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp. Date
Date Signature of Contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
(%,) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure.is not intended or offered for
sale (Sec. 7044. Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
() I am exempt under Section , B&P.C. for this reason
'bate tf Signature of Owner �' A
• ti. °'
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier Policy No.
(This section need not be completed if the permit valuation is for $100.00 or less).
() I certify that in the performance of the work for which this permit is issued,
I 's° Ll not employ any person in any manner.so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation provisions of Section of the Labor
Code, I shall forthwith comply with those provisions.
/fate:to - Applicant
tlhzi le -
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application -is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnity
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within, 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby. authorize representatives of this City to enter upon
the above-mentioned property for inspection purposes. r
ignature (Owner/Agent)9fiw.�.I Date /% w {
• BUILDING PERMIT PERMIT# CONTROL#
4294
DATE `` �A � VALUATION �����t�ii LOT TRACT
1•i 'Z ]
JOB SITE e}J}.
ADDRESS 80- 65 W LST`'ARD "o OIR er '
OWNER;
CONTRACTOR / DESIGNER //ENGINEER
C�J.J-N (Y'T'lIy KlNru,�R
.
iNt"It)IAV)iyER,
9020 i :t1XINV'AkD 140 OR
11A 011 JjINTA. G r1 92r2
USE OF PERMIT
rig#?%T w ITitiL .itFNIc') Rb,
123 SY. PAJ30,
VA:3KJ t, (JV Vl:; C%_iOr-4 3,'XFIB<iw 3; ,.
�%;�'B'e�dt��"�'.$17� i.:`�e�ti'[•, �3i' �:+C�i�:�' �4J+�'1': }zw'
;�,�v�i�.iiQ3
1%)•.AN 04Ef`K FEE )t?) -()f)() d• '➢-Z):S S5� 05
HE ift-WOW119-000 1.60
%if�..`iA%J.iu.Al, i�i3i� iQi.•QiN)�<i.3.-iNtia $.ifi.i"sg
�
,..
0XIC17RICAL.i.bl lilf••� �i1()-( {) 51'�.af3
_
4'110NO I41;C131It'S'N I til:. Fei.:'a#T3 i.ttl-U(}f) A%d 3t) 5.52
r
IJ.EI,`ft Yf:1,i, GJid�"is.st.lB "['iC�h';t4Y.�1) l?1.. C°umct�
NOV 2 0 1996
RECEIPT
DATE
BY /.
DATE FINALED _
INSPECTOR
INSPECTION RECORD
OPERATION I DATE I INSPECTOR
BUILDING APPROVALS
Set Backs
Forms & Footings
Slab Grade
Steel
Roof Deck
O.K to Wrap
Framing
Insulation
Fireplace P.L.
Fireplace T.O.
Party Wall Insulation
Party Wall Firewall
Exterior Lath
nru all _ Int I ath
OPERATION I DATE I INSPECTOR
MECHANICAL APPROVALS
Underground Ducts
Ducts
Return Air
Combustion Air
Exhaust Fans
F.A.U.
Compressor
Vents
Grills
Fans & Controls
Condensate Lines
Final
POOLS - SPAS
BLOCKWALL APPROVALS steel
Set Backs Electric Bond
Footings Main Drain
Bond Beam Approval to Cover
Equipment Location
Underaround Electric
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Neater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
I Pool Cover
I Sewer Connection I I I Encaosulation I I I
COMMENTS:
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Final
Utility Notice (Perm)
Desert Sands Unified School District
Notice' 82-879 Highway 111
Indio, CA 92201
Document Cannot Be'Duplicated ' • , '
619-775-3500
CERTIFICATE OF COMPLIANCE -
Date . 11/8/96 ', APN # 649-080-006,
No. 14994 Jurisdiction La Quinta
Owner Name Glen W. &`Dorothy Kinum Per #
No, 80205 Street Westward Ho Dr. , Lcg #
City La Quinta zip 92253 Study A: -ea 229. r
Tract # Lot # Square Footage 128
Type of Development Residential Addition No. of Units 1
Comments
At 'the present time, the Desert Sands Unified School District does not collect fees on
garages/carports; covered patios/walkways, residential additions under 500 squire feet, detached
accessory structures or replacement mobilehomes. It has been determined the above-named owner is
exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
E •
EXEMPT
This certifies that school facility fees imposed pursuant to Government Code 53080`
in the amount of 0.00 X 128 or $ 0.00
`—the property listed above and that building permits and/or Certificates of Occupancy for
this square footage in this proposed project may now be issued.
Fees Paid By .n/a Telephone X342-3876;
1 w,;
r Name on the check ` ..
BY Dr. Carol McGrew • 4 �'`-
Administrator in Charge
Fee collected /exempted by Pauline Pearson . Exempt $Q00
Check No. n/a.
Signature On
Collector: Attach a'copy of county or city plan check•°application form to district copy for' all waivers.
Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting
` . N
. � .,,
.S :-
o .�
_� �
x�
o
n '�
4
_
S
_�
r
��
t
.
��
��
�
iI
�_
1 cam\ 1\
7 -VALUE
.1 Y., C H NC AFACE'S
THAI' SUPPOoRT
X!V] AX There on: it imml-Icr of :ig It i,-,- 111`01:CIJUrO d 0.. CM1 1)1'i:, I iCt. d) QiC
aging chamcterjsriLs. These pr,,cc(.1ui:.:.; arr (01"w';. -d by celotcx
and ii.wc I)ccn replic:ited in :.i,,zu,iI lot.Q-rum le5rs, Ulktin as tonk!
SEUCTION
I%ilyi.ioc%.:iniirmc Ind mi-kided :ire blown, with M.-iny COMP'.-mie; ichme, po!vksoc )rmuriv:c f"mill imuLIL1,51).1.
rc!rl_' rant .:t.scs iti rhe cdk. These- prudi.K.t, sEJr( with eXCeptio.111-
coday u5C. 'iX L11CTtk '.u-OhicriC 1211-1t tt- .:sml,IiSjj ri%cir R-wilues.
MiS, 16,j) R.vul,W-s. hiuh as tO per inch. Howcvcr, tUpendtfig These R-v-,t1Lw.s are bl..;Cd 01) R:C77IK`,A 281-1 -or PIMA 1.0.1.
ppem of r(,,.,f it15I.IIaLio1)1,, n(')( [,) prc�lj.:r lon:!,.E�Jm stabilized R,v:dues cd
LhI� faccr�. rh,:�tc pr,.)jjj,jj lk�sc s0t))v of dI,5 tmI-.pej up.,, (,Is
%vl.(Il f-Aystyruic or r6cvogen aiid orher fouti-L intuition. The reality is rFjjt (Csti:J Oflt,:r LI.je.;C
'.j t t A
Ospk.niC 4:11se$ Thc 0e11 WAL.' ill -Id dilute tke.rtfiriger, condirioning Priced urns coi.dJ sitow R-y-alue-i of 7 -it 7,2 per indl,
n r i,c, I...11,11clis with tivskiLitiom). This results in bI.M ULE1.011y age co K5.6 (W2.6 on 1/1' bo.sis).
.A,J:)i1i_CLI P�'VAILIf. Thi,'IM-OCc.s� LW) t=ike yeirq to fully'
INSIST ON LONG-TERM STABILIZED R -VALUES.
THERMAX SHEATHING R -VALUES
STABILIZED K -VALUE INFORMATION FOR COMPARISON PURPOSES
- --------------
w-fliw, sov.,.j X18* 3:4" Ila- 11 1 114' 1 ir. 2* 2 1114, I 1/221 *23!4' Y 3 !"'. 3 1 3 3,4' 41 4 1/4
0.,A) 67 2) (6i,i) 64.91 (7c,1 kA2*�) fl,jal
R -Value of 75'F Mean Temp,
I J 6 4.6 54 5.3 I.i U 108 14.4 wlau 19,; .'!a, CIA 27.0 3u .0
SV31em R-Vtv',Ie With 3/4' (19.1 rnm) Air Space'
10 0 118 1 '1.!. 17 2 !9.0 2(,.,R 22.6 2 G
v 64 7 3 .52 9.1 44
ortit nc-minu rind are ofovicieci for design intmmotion, For fl-vuueE at omer rrvear) rrr,ceratui,Rs, _-c,!*1S,.j,t.(.',F.I0tqx,
11`115 Lj..j,:7frI JP-vf:ltjl> is MIL, crji.j--,jIrjtad wrien the oitiminum. A)!1 surface b nstallourtPxtic,314' at( 5pzie. n r.2 w,,,i!l. vne ct.xpiuct ri-vott, .
mean turrpsujttjrr is me(I added to Tnc, air SPcice P-voluF, cf 2.77 (foundeei to 2.8) !o yieici !his ,,v,;tem re-vvt.,F- '1"4' f.16m frie-, ASHRAE
Fijnonack ;%inciamentol.i s provio.3a to (j`i,ist oesV.iefs cf ig,,clenTicii CNIstrucliorl, to comply w1n Feciercit TtaoG C-xivnissi(.r,
1i io nraT !1(,)w. Tno t%.,fjher ItIc, P -value trip grem_rc,r tme imuicting rowpr. Ask your sei!er or tne !act sr.eet
r.
AppjoveCj (()f expo,_4t:t
TYPICAL PHYSICAL PROPERTIES
Property of F*11 Faced Board
Test Mothod
o,:f ;37)
Incil 03
As P,)tmacnm i) Pe,rn;
P/10M.-J!
Wate, Arsorption
ASTM
V.i Man J.3 k.
F-'lexu,ol 1;1rengtl, iri. psi
It than 40 Q)
!C',V 1(. %-71 ;6
i
TITLE 24 REPORT FOR:
GLENN KINUM - EXISTING./ ADDITION
2 o a _WESTWARD HOS
LA QUINTA,.CALIFORNIA
PROJECT DESIGNER:
b�
REPORT PREPARED BY:
JOAN D. HACKER
INSU-FORM, INC.
6848.7 HIGHWAY 111, SUITE _56
CATHEDRAL CITY, CA 92264
(619) 324-0216
Job Number:
Date.: 11/19/1996
The COMPLY 24 computer program has been used to perform the calculations
summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the
Residential and Nonresidential'Building Energy Efficiency Standards.
This program developed by Gabel Dodd Associates (510) 4128-0803.
CERTIFICATE OF COMPLIANCE: Residential (part I of'2) <CF71R page 3 of 19
Project Name: GLENN KINUM - EXISTING / ADDITION Date: 11/19/1996
Address: WESTWARD HOE
t LA QUINTA, CALIFORNIA Building.Permit-No
Designer: Checked by /,Date
Documentation:•INSU-FORM, INC. COMPLY 24 User 2655
GENERAL INFORMATION.
Compliance Method: COMPLY 24 version 4.11
Climate Zone: 15,
Conditioned Floor Area: -•1927 sgft
Building Type: Single Fam.Det
Building Front Orientation: 0 deg (N).
Number of Dwelling Units: 1
F1oor.Construction Type: Slab on Grade
BUILDING SHELL INSULATION
Component U -Value Location/Comments
R-11 Wall (W. 11.2x4.16) 0.098 EXISTING HOUSE -
Solid Wood Door 0.387 EXISTING HOUSE
R-13 Wall (W.13.2x4.16) 0.088 -ADDITION
R-19.Roof (R.19.2x8.16), - 0.051 EXISTING HOUSE
R-30 Roof(R.30.2x12.16) 0.035 ADDITION
Slab Perimeter w/R-0.0 0.900 EXISTING HOUSE
Slab Perimeter w/R-0'.0 0.720 EXISTING HOUSE }
Slab Perimeter w/R-0:0 0.900 ADDITION
FENESTRATIONIt Shading'Devices Frame
Orient. Area U -Val Type Interior Exterior =OH SF Type
Front (N)'- 20.0 0.94 Double Std Drape >. Standard Bug Scr Yy N Metal
Left (E) 16.0 0.94 Double Std Drape Standard Bug Scr,Y N'Meta.1
Left .(E) 40.0 0.94 Double Opaque White Rl Standard Bug.Scr Y N Metal
Back (S)r 32.0 0.82 Doubl-e Light Blirid Standard.'Bug Scr Y N Metal
Back • (S) 15.8.0 0.94 Double Std Drape Standard Bug Scr Y N Metal
THERMAL MASS ' Area Thick' •T
Type Covering (sf) (in) Location/Description ,
---------------------------------- ;------ ---------------- --------------.
Concrete, Heavyweight Exposed 360 3.50 Slab on Grade 4 i
Concrete, Heavyweight, Covered 1440 3.50 Slab on Grade
Concrete, Heavyweight Exposed 127 3.50 Slab on Grace a `'
CERTIFICATE OF COMPLIANCE: Residential
(part 2 of 2) CF -1R page 4 of 19
Project Name: GLENN KINUM —EXISTING
/ ADDITION
ti
Date: 11/19/1996 ,
Documentation*.` INSU-FORM, INC.,
COMPLY 24 User 2655
HVAC SYSTEMS Minimum Distrib Type
Duct TStat
System Type.Efficiency and,Location
RVal Type Location/Comments
Furnace 0.780 AFUE Ducts in Attic
2.1 SetBck EXISTING HOUSE
PackAirCond 8.900 SEER Ducts'in Attic
2.1 SetBck
Electric 3.410 HSPF Fan /. No Ducting,
N/A SetBck ADDITION'
'RoomAirCond:8.500 SEER Ducts in Attic
4.2 SetBck y
Water No. Tank Ext.
WATER'HEATING-..SYSTEMS
..Heater. in Energy Size Insul
System Name Distribution
Type Type Sys Factor (gal)- R -Val
Std Gas 50 gal .or Less Standard
StorGas 1 0.53 50,.0 ` , 12.0
j
AFUE ~
WATER HEATER EQUIPMENT DETAIL
/Rec Rated Stdby Tank Pilot
System Name ', `System Type
Eff Input 'Loss R -Val Light :� ,
Std Gas 50 gal or Less DomesticHW
0.780 40000 0.040 0.0 10
.'SPECIAL FEATURES/REMARKS .
;
' COMPLIANCE STATEMENT
,
This Certificate of Compliance lists
the building features and performance
specifications needed to comply with
Title 24-, Parts'1 & 6 of the Califor-
nia Code of.Regulations,,and the administrative
regulations to implement
them.- This certificate has been signed
by the individual' with .overall
design responsibility. When this certificate
of compliance is submitted for.
a single building plan to.be built in
multiple orientations, any shading
feature that is.varied is indicated in
the,Special-Features/Remarks*section
DESIGNER or OWNER
DOCUMENTATION AUTHOR
.(Per Business & Professions Code) .
JOAN D. HACKER
INSU-FORM, INC.,
68487 HIGHWAY 111, SUITE `56
CATHEDRAL CITY, CA 92264
Lic #:
(619) 324-0216 '.
(signature) (date)
(s' ature) (da e)
ENFORCEMENT'AGENCY
Name:
'
Title:
Agency:
Telephone:
(signature/stamp) (date)
MANDATORY MEASURES CHECKLIST (part•l of 2) MF -1R page 5 of 19
Project Name: GLENN_KINUM - EXISTING / ADDITION Date: 11/19/1996
Documentation:,INSU-FORM, INC. COMPLY 24 User 2655
NOTE: Lowrise residential buildings subject to the Standards must contain
these measures regardless of the.compliance approach used. Items marked
with an asterisk (*) may be superseded by more stringent compliance '
requirements listed on the Certificate of'Compliance. When this checklist
is incorporated into the permit documents, the features noted shallbe
considered by all parties as binding minimum component performance
specifications -for the mandatory measures whether they are shown elsewhere
in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES Enforcement.
o Sec. 150(a):,Minimum R-19 ceiling insulation. * r
o'Sec. 150(b): Loose fill insulation manufacturers
labeled R -Value.
0 Sec.`150(c): Minimum.'R-13 wall insulation in framed walls
(does not apply to exterior mass walls).
o Sec. 150(d): Minimum'R-13 raised floor insulation in framed }'
floors; Minimum R-8 in -concrete raised floors.
o Sec. 150(1):•.Slab edge insulation - water absorption ralte
no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch. ' Y
o'Sec. 118: Insulation specified or installed meets California
Energy Commission quality standards. 'Indicate Type &--form.
o Sec. 116 -117 -Fenestration Products, Ext Doors &.Infil/Exfil Controls
a. Doors and windows between conditioned and unconditioned'
spaces designed to limit air leakage.
b.: Manufactured fenestration products have label.w/certified Ti -Value
c. -Exterior doors and windows weatheistripped; all jcints
and penetrations caulked and sealed. `
.o Sec. 150(g):"Vapor-barriers mandatory in Climate Zones 14
and -16 only. ,
o Sec.,150(f): Special infiltration barrier installed to
comply with Sec. 151 meets Commission quality standards.
o'Sec. 150(e): -Installation of Fireplaces,' Decorative Gas r
Appliances and Gas'Logs ;
1. Masonry and factory -built fireplaces have:
a. -Closeable metal or glass door
b. Outside air intake with.damper and control
c. Flue damper and control
.2. No continuous burning gas pilots allowed.`
MANDATORY MEASURES CHECKLIST (part 2 of 2) MF -1R page 6 of 19
--------------------------------=------------------------------------------
Project Name: GLENN KINUM -,EXISTING / ADDITION Date: 11/19/1996
Documentation:; INSU-FORM, INC. COMPLY 24 User 2655
------------------------------------------------------ --------------------
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Enforcement
o Sec. 110-13: HVAC equipment, water heaters, showerheads
and faucets certified by the Commission.
o Sec. 150(i):.Setback thermostat"on all applicable
heating systems.
o Sec. 150(j): Pipe and Tank Insulation
1. Indirect hot water tanks (eg unfired storage tanks or
backup solar hot water tanks) have insulation blanket
(R-12 or greater,) or combined interior/exterior insulation
(R-16 or greater).
2. First 5 feet of pipes closest to water heater tank,
non -recirculation systems,.insulated (R-4 or greater.
3. All buried or exposed piping insulated in recirculation
sections of hot water=system.
4. Cooling system piping below 55 F insulated.
5. Piping insulated between heating source and indirezt hot.
water tank.
o Sec. 150(m) Ducts and Fans
1. Ducts constructed, installed and sealed to comply with
UMC Sections 1002 and 1004; ducts insulated to a minimum
R-4.2 or ducts enclosed entirely within conditioned space.
2. Exhaust systems have backdraft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible manually operated
dampers.
o Sec. 114:Pool and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, cn-off
switch, weatherproof operating instructions, no electric
resistance heating and no pilot light.
2. System is installed with:
a. At least 36" pipe between filter and heater for future
solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch.
o Sec. 115: Gas-fired central furnace, pool heater, spa heater
or household cooking appliance have no continuously
burning pilot light. (Exception: Non -electrical cooking
appliance with pilot < 150 Btuh)
LIGHTING MEASURES
o Sec. 150(k): Lighting - 40 lumens/watt or greater for
general lighting in kitchens and rooms with water closets;
and recessed ceiling fixtures IC (insulation cover) approved.
HVAC ZONE HEATING & COOLING LOAD SUMMARY
page 7,of 19
Project Name: GLENN KINUM - EXISTING / ADDITION
Date: 11/19/1996
Documentation: INSU-FORM, INC.
COMPLY 24 User.2655
HVAC ZONE DESCRIPTION
HVAC Zone Name:
EXISTING HOUSE
Heating System Name:,
Day&Night 584AN060080
Cooling System Name:
System Multiplier:
" 1
Fan Schedule:
24 Hr Fans STD
Peak Load Method:
iCOINCIDENT `
Relative Humidity:
50
COOLING .
`SPACES IN,THIS•ZONE PEAK HEATING
PEAK SENSIBLE LATENT.
t
EXISTING HOUSE (Jan 12am) 37651
(Aug 2pm)' 28904 1128
TOTAL SPACE LOAD 37651
28904 1128
Duct Gains & Losses: 3765
2890
Ventilation: ( 0 CFM). 0
0 0
Return Air Lighting Gain
0
,.TOTAL SYSTEM LOAD 41416
31794 1128
SYSTEM OUTPUT AT DESIGN CONDITIONS 80000.
;" 41857 12312
NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment
which will heat or cool this,zone during the
design conditions indicated.
These numbers include no safety factor, and
the HVAC contractor should
oversize by a reasonable margin to account -for
variations in weather
conditions and the'pick-up capacity.required
to bring the zone to temper-
ature as a result of a setback thermostat,
Those responsible for final ,
,equipment selection, should note -that Sensible
and Latent Cooling -Loads are
indicated to allow for accurate comparison with manufacturer's output -data.
•
.RESIDENTIAL SPACE HEATING LOAD SUMMARY
page
8 of 19
Project Name: GLENN KINUM - EXISTING
/ ADDITION
DGte:
11/19/1996
Documentation: INSU-FORM, INC.
COMPLY 24 User 2655
Space Name:
EXISTING HOUSE
Design Indoor.Dry,Bulb Temperature:
70 F
.Design Outdoor Winter Dry Bulb Temperature:
29`F
Design Temperature.Difference:
41 F
Conduction
Area
U -Value
TD
Btu/hr
R-11 Wall (W.11".2x4.16)
1066.0
x
x,.0.0978 x
41.0
= 4275
Solid Wood Door20.0
x
0.3872. x
41.0 -=
318
DOUBLE
20.0
,x
0.9400 x
41.0
= 771
DOUBLE
16.0
x`
0.9400 x
41.0
= 617
DOUBLE
158.0
"x
,' 0.9400 x
41.0
=- 6089
R-19 Roof (R.19.2x8.16)
1800.0
x
0.0512 x
41.0
= .'3779
Slab on Grade Perim =
'40.0
x
43
= 1720
Slab on Grade - Perim =
220.0
x
43'
_ ',9460
Infiltration: 1.60 x 0.,018 x 1800 sf
x 8.•0
ft
x 1.00 AC x
41,.0
_ 10623
1, TOTAL
HOURLY
HEAT LOSS FOR .SPACE'37651
Heating AirFlow: .37651-,.Btu/hr /
[1.08 x
35
F Deltafl] =
996
cfm
RESIDENTIAL SPACE COOLING LOAD SUMMARY
page
9 of 19
Project Name: GLENN KINUM - EXISTING
/ ADDITION
Date:
11/19/1996
Documentation:,,INSU-FORM;"INC.
COMPLY.24
User
2655
Space Name:
EXISTING
HOUSE
,
Design Indoor Dry Bulb Temperature:
78 F
Design Outdoor.Summer Dry Bulb Temperature:
11216F
Design Temperature. Difference:
34-F
Conduction Y
'Area
U -Value
-DETD'
Btu/hr--
.-----------------------
R-11 Wall (W. 11.2x4.16)'
------
1066.0
x
-------
0.0978 x
---- ♦
29.6 =,.
------y .
3086
Solid Wood Door _
20.0
x
0.3872, x
29.6. =
229
DOUBLE x
- .20.0
x
0.9400 x
34.0 =
639
DOUBLE
16.0
x
0.9400 x
34.0.,=
511
DOUBLE F'.
.158.0
x
0.9400- x
34.0 _
5050,
R-19 Roof (R.19.2x8.16)•
1800:0
x
0.0512 x
50.0 =.
;4608
Infiltration: 1.00 x 0.018-x 1800
sf x 8.0'.ft
`x
1.00 -AC x
34.0 _
8809
Shaded
;.Unshaded
Solar -Gain Orient.- -
--------------------------------
Area ' ; SGF
----
Area SGF ,
- -
SC.
DOUBLE North [
---
0. 0, x 15
+
- - ---
12.0 x 15 ]
----
x '0 : 66
119.1
DOUBLE North [
0.0 x15
+
8.0 x 15]
x 0.,66
79,
DOUBLE East [
6A x•15
+
10.0 x 73]
x 0.,66
_ 540
DOUBLESouth. [
106.0 x.15
+,
0.0 x 32]
x 0--.66
1048
DOUBLE South [
52.0 x 15
+
0.0-x'32]
x 0.66
= 514
Internal Gain Op Frac.
Area
Heat
Gain
Conv.
f f
,.
Lighting 1.00
x 1800.0
x
0.200 x
3.413 =
1229
'Equipment 1.00-
x 1800.0_
x
0'.100 x
3.413 _�'
614
' Occupants 1.00
x 1800.0
x
225 /
333 _
1216
�+ TOTAL HOURLY
SENSIBLE HEAT
GAIN•FOR SPACE•,
28904
Latent- Gain Op Frac.
Area"
Heat
Gain
Conv. _'
.Btu/hr
Equipment ': 1.00
x 1800.0
x
0.000 x
3.413 =
0 .
Occupants 1.00
x 1800.0
x
225 /
333 =
1216
Infiltration: .1.00 x 0.018 x 1800
S x 8.0 ft
x 1.00 AC x
-0.3 _
-81
TOTAL HOURLY LATENT'HEAT
GAIN FOR SPACE
1128
Cooling AirFlow: •28904 Btu/hr
/ [1.08 x .23
F DeltaTl)]
= 1164.cfm
- - i
HVAC ZONE HEATING & COOLING LOAD SUMMARY
--------------77------------------------------------------------------------
-page 10 of-19
Prject Name:'GLENN KINUM - EXISTING /.ADDITION
Date: 11/19/1996
' Documentation: INSU-FORM, INC.
---------------------------------------------------------------------------
COMPLY 24 User 2655.
HVAC ZONE DESCRIPTION "
HVAC Zone Name:
ADDITION
Heating System Name:
Cooling System.Name:
HAMPTON BAY
System Multiplier:
1
Fan Schedule:'
Day Fans STD
Peak Load Method:
-.COINCIDENT
Relative Humidity:,
50 %
COOLING
SPACES IN THIS ZONE PEAK HEATING
PEAK SENSIBLE LATENT
ADDITION (Jan 12am) '6095
-------
(Aug 2pm) 4261 86
TOTAL SPACE LOAD 6095
-------- ------
4261 86
Duct -Gains & Losses: 610
426.
Ventilation: ( 0` CFM)' 0
0 0
Return Air Lighting Gain
0
TOTAL'SYSTEM LOAD 6705
4687r 86
SYSTEM OUTPUT AT DESIGN CONDITIONS 0
7488 3529
NOTE: The TOTAL'.SYSTEM LOAD shown represents
the minimum, -size, equipment
which will heat or cool this zone during the
design conditions indicated.
These numbers include no safety factor, and the
HVAC contractor should
oversize by a reasonable margin to account for
variations.in weather
conditions and the pick-up capacity required
to bring the.zone to temper-
ature as a result of a setback•thermostat. Those responsible for final
equipment selection should note that Sensible
and Latent Cooling Loads are
indicated to allow for accurate comparison.with
manufactuker's output data.
- t
RESIDENTIAL SPACE HEATING LOAD SUMMARY page 11 of 19
----------------------------------------------------------
Project Name: GLENN KINUM - EXISTING / ADDITION Date: 11/19/1996
Documentation: INSU-FORM, INC. ► �r COMPLY 24 User 2655
- ' , P
Space Name* ADDITION
"Design Indoor.Dry Bulb'•Temperature: . 70 F s
Design Outdoor Winter Dry Bulb Temperature:- 29,:.F
Design Temperature,Difference: 41 F
Conduction Area U=Value TD Btu/hr
------
.R-13 Wall (W. 13'. 2x4-.16). 228.0 x 0.0885- x , 41.•0 827
DOUBLE 40.0 x 0.9400 x 41.0 1542
DOUBLE 32.0 x 0.8200 x 41.0 = 1076
R-30 Roof(R.30.2xl2.16) 127.0, x ,0.0347 x 41.0 = 181
Slab on Grade Perim = 40.0 x 43 = 1720
Infiltration: 1.00 x 0.018 x 127 sf x 8.0 ft x.1-.00 AC x 41.0 750
TOTAL HOURLY HEAT LOSS FOR SPACE 6095 '
Heating AirFlow: 6095 Btu/hr / [1.08 x 35 F•DeltaTil = 161 cfm
,'
r
•RESIDENTIAL SPACE COOLING LOAD SUMMARY page 12 of 19
Project Name: GLENN KINUM'- EXISTING / ADDITION Date: 11%19/1996
Documentation:`INSU-FORM, INC. COMPLY 24 User 2655
.Space Name: ADDITION
Design 'Indoor Dry Bulb Temperature: 18 F
Design Outdoor Summer Dry Bulb Temperature: 112 F
Design Temperature Difference: 34 F
Conduction 'Area U -Value DETDBtu/hr
R-13 Wall (W.13.2x4.16). 228.0 x 0.0885 'x 29.6 = . 597
DOUBLE 40.0 x 0.94001 x 34.0 = 1278
DOUBLE 1 32.0 x .0.8200 x 34.0 = 892
R-30 Roof(R.'30.2xl2.16) 127.0 x 0.0347 x 50.0 221
Infiltration: 0.00 x 0.018 x• 127 sf x 8.0 ft x 1.00 AC x 34.0 = 0
Shaded Unshaded
'Solar Gain; Orient. Area SGF Area SGF SC
DOUBLE *.'' East [ 40.0 x 15 + 0.0'x 13] x 0.34 203
DOUBLE' South [ 32.0 x 15 + t 0.0 x 32]•x .0.45 = 217
Internal'Gain.'.' , Op Frac. Area Heat Gain Conv..
------------------------------- --------------- -----
Lighting 1.00 x 127.0 x 1.500 x 3.413 = 650
Equipment 1.00 x 127.0 x 0.100 x 3.413 = 43
Occupants 1.00 x 12.7.0 x 225 / 333• = 86
TOTAL HOURLY SENSIBLE HEAT GAIN FOR SPACE, 4261
Latent'-Gain
Op Frac. Area Heat Gain Conv. Btu/hr
------------------------------- --------------- - -----
Equipment 1.00 x 127.0 x '0.000 x .3 .413 0
Occupants. 1.00, x 127.0 x. 225 / 333 -86
Infiltration: 0.00 x 0.018 x 127 sf x. 8.0 ft x 1.00 AC x -0.3 = -0
TOTAL HOURLY LATENT HEAT GAIN FOR SPACE 86
Cooling*AirFlow: 4261 Btu/hr / [1.08 x 23 F.DeltaT)] 172'bfm
COMPUTERMETHOD SUMMARY C-2R page 13 of 19
Project Name: GLENN KINUM -EXISTING / ADDITION Date: 11/19/1996
Documentation: INSU-FORM, INC. COMPLY 24-User 2655
RESSIM RESULTS NOT CALCULATED '.
GENERAL INFORMATION
Compliance Method: COMPLY 24 version 4.11 a
Climate Zone: 15
Conditioned Floor Area: 1927 sgft.
Building Type: Single Fam Det
Building Front Orientation: 0 deg (N)
Number of Dwelling;:Units: 1
Number of Stories: 1 w
Floor Construction Type: Slab on Grade.`
Total Conditioned Volume. 15416 cuft
Conditioned Footprint Area: 1927 sgft
Ground Floor Area: 1927 sgft
BUILDING ZONE.INFORMATION
Floor # of Vent
Zone Name Area Volume ,Units Zone•Type TStat Type Hgt Area
EXISTING HOUSE 1800 .14400 0.93 Conditioned Setback 2 n/a
ADDITION, 127 1016 0.07 Conditioned Setback- 2 n/a
OPAQUE SURFACES Act Solar
Type Area'U-Val Azm-Tilt Gains Form 3 Reference Location/Comments
---- ---- ----- --- ---- ------------------- --------- --------------------
ZONE NAME EXISTING HOUSE
Wall 280 0.098- 0 90 Yes R-11 Wall (W.11.2x4.16) EXISTING HOUSE
,.Door 20 0.387 0 90 Yes Solid Wood Door EXISTING HOUSE
Wall 224 0.098 90 '90 Yes R-11 Wall (W. 11.2x4.16) EXISTING HOUSE
Wall 322 0.098 180 90 Yes R-11 Wall (W.11.2x4.16) EXISTING HOUSE
Wall 240 0.098 270 90 Yes' R-11 Wall (W:11.2x4.16) EXISTING HOUSE"
Roof 1800 0.051 0 22 Yes R-19 Roof (R.19.2x8.16) EXISTING HOUSEr
'ZONE NAME =, ADDITION
Wall 40 0.088 90 90 Yes R-13 Wall (W.13.2x4.16) ADDITION
Wall 1.08 0.088 180 90 -Yes R-13 Wall (W 13. 2x4. 16) ADDITION
,Wall 80 0.088 270 90 Yes R-13 Wall (W.13.2x4.16) ADDITION
Roof -127 0.035 0 22 Yes R-30 Roof(R.30.2xl2.16) ADDITION '
COMPUTER.METHOD SUMMARY C -2R page 14 of 19
---------------------------------------------------------------------------
Project Name: GLENN KINUM - EXISTING / ADDITION Date:'11/19/1996 A
Documentation:'INSU-FORM, INC. COMPLY 24 User 2655
PERIMETER LOSSES F2 Insulation
Type Length Factor R -Val- Depth Location/Comments
ZONE NAME = EXISTING HOUSE
Exposed 0,40.0 0.90 0.0 0 in EXISTING HOUSE
Covered '220.0 0.72. 0.0 0 An EXISTING HOUSE
ZONE NAME = ADDITION '
Exposed. 40.0 0:90 0.0 0 in ADDITION
FENESTRATION SURFACES SC
Act. Glass
# Type Area Frame Div U -Val Azm Tilt Only Location/Comments
ZONE NAME. EXISTING HOUSE- v
1 Wdw Front (N). 12.0 Metal,No 0.94 _.0 90 0.88 EXISTING HOUSE
2 Wdw Front (N) 8.0.Metal No 0.94 0 90 0.88 EXISTING HOUSE
3 Wdw Left (E): 16.0 Metal No 0.94 90 90, 0.'88 EXISTING HOUSE
4 Wdw Back (S),106.0 Metal No 0.94 180 90- 0.88 EXISTING HOUSE
5 Wdw Back (S) 52.0 Metal No'- 0.94 180 90 0.88 EXISTING HOUSE
ZONE NAME ADDITION
6 Wdw Left (E) 40.0 Metal No 0.94 90. 90: 0.88.ADDITION
7 Wdw Back. (S) 32.0 Metal Yes 0.82 180 '90 0.88 ADDITION
INTERIOR & EXTERIOR SHADING
# 'Type Interior -Shade Type SC Exterior Shade Type SC
-- --------------------------- ---------------------------, ----
1 Wdw`- Std Drape 0.78 Standard Bug Screen 0.87
2•. Wdw Std Drape 0.78 Standard Bug Screen '0.87
3 Wdw Std Drape M. 0.78 Standard Bug Screen i 0.87
4-Wdw Std Drape 0.78 Standard Bug Screen 0.87
.5 Wdw; Std Drape 0.78 Standard Bug Screen 0.'87,
6-Wdw -Opaque White Rlr Shade 0.40 Standard Bug Screen 0.87,
7 Wdw Light Blind 0.58 Standard Bug Screen 0.87
� �: .. ', - .. '• ted, -
COMPUTER METHOD SUMMARY C -2R page 15 of 19
---------------------------------------------------------------------------
Project Name: GLENN KINUM - EXISTING /'ADDITION Date: 11/19/1996
Documentation: INSU-FORM, INC. COMPLY 24 User 2655
OVERHANGS/SIDE FINS
--Window-- --- Overhang=----- ---Left Fin--- ---Right Fin--
# , Type- Ht. Wd Len Ht LExt RExt Dist Len Ht Dist Len Ht
1 Wdw 4.0 3.0 2.0 0.1 2.0 2.0
2 Wdw 4.0 2.0 2.0 0.1 2.0 2.0
3 Wdw 4.0 4.-0 2.0 0.1 2.0 2.0
4 Wdw 6.8- 8.0 10.0 0.1-10.0 10.0
5 Wdw 6.5 4.0 10.0 0..1 10.0 10.0
6 Wdw 6-.8 6.`0 10.0 0.1 10.0 10.0
7 Wdw 4.0 4.0 2.0 0.1 2.0 2.0
THERMAL MASS Area Thick Heat •Inside Location
Type (sf) (in) Cap Cond Form 3 Reference R -Val. Comments
ZONE NAME = EXISTING HOUSE
Exposed Slab 360 3.50 28 0.98 n/a 0 ,
Covered Slab 1440 3.50 28 0.98 n/a 2
ZONE NAME = ADDITION
Exposed Slab 127 3.50 28 0.98 n/a 0
HVAC SYSTEMS Minimum Distrib Type Duct TStat
System Type Efficiency and Location RVal Type Location/Comments
Furnace'. 0.780-AFUE Ducts in Attic 2.1 SetBck EXISTING HOUSE
PackAirCond 8.900 SEER Ducts in Attic 2.1 SetBck
Electric 3.410 HSPF Fan / No Ducting N/A SetBck ADDITION
RoomAirCond 8.500 SEER Ducts in Attic 4.2 SetBck
Water No. • Tank Ext.
WATER HEATING.SYSTEMS Heater in Energy Size Insul'
System Name Distribution Type Type Sys Factor -(gal). R -Val
----------------------- ------------------ ------- --- ----- ----- -----
Std Gas 50 gal or Less Standard StorGas 1 0.53 50.0 12.0
AFUE r
,WATER.HEATER EQUIPMENT DETAIL ./Rec Rated Stdby' Tank Pilot
System Name System Type Eff Input Loss R -Val, Light
Std Gas 50 gal or Less DomesticHW 0.780 40000 0.040 0.0 0
SPECIAL FEATURES/REMARKS
COMPUTER METHOD SUMMARY C -2R page 16 of 19.
---------------------------------------------------------------------------
Project Name: GLENN KINUM - EXISTING Date: 11/19/1996
Documentation: INSU=FORM, INC: COMPLY 24 User 2655 !
RESSIM'RESULTS NOT CALCULATED
GENERAL INFORMATION
Compliance.Method: COMPLY 24 version 4.11 ;
Climate Zone: 15
Conditioned Floor. Area: 1800. sgft .
'Building Type: Single Fam Det
Building Front Orientation:'0 deg (N)
Number of Dwelling Units: 1_
Number, of Stories : 1 -
Floor Construction Type: Slab on Grade
Total Conditioned Volume: __ 14400 cuft
Conditioned Footprint Area: 1800 sgft
Ground Floor Area 1800.sgft
BUILDING.ZONE INFORMATION
Floor` # of,� Vent
k
Zone Name Area Volume Units Zone,Type TStat Type Hgt Area
'EX•ISTING HOUSE •1800 14400 1.00 Conditioned Se-tback 2 n/a
OPAQUE SURFACES Act Solar
Type'Area U-Val•Azm Tilt Gains Form 3 Reference Location/Comments
ZONE NAME ='EXISTING HOUSE
Wall° 280 0.098 0 90 Yes R-11 Wall (W. 11.2x4.16) EXISTING HOUSE
.Door 20 0.387 0 90 Yes Solid Wood Door EXISTING HOUSE
r Wall 22.4 0.098 90 90 Yes R-11 Wail (W.11.2x4.16) EXISTING HOUSE
Wall 282 0.098 180 90 Yes, R-11 Wall (W.11.2x4'.16) EXISTING HOUSE
Wall '240 0.098 270 90 Yes R-11 Wall (W.11.2x4..16) EXISTING HOUSE
;Roof 1800 0.051 0 22 Yes R=19 Roof (R. 19.2x8.16) EXISTING HOUSE
r
B
. COMPUTER METHOD
--------------------------------------------------------------------------
SUMMARY
C -2R
page '17 of 19
Project Name:
GLENN KINUM - EXISTING
Date:
11/19/1996
Documentation:-INSU-FORM,
INC.'•,
COMPLY
24 User 2655
----
PERIMETER'LOSSES
F2
Insulation
Type
Length Factor -.R-Val
Depth Location/Comments
ZONE ,NAME = •EXISTING
HOUSE
Exposed
90.0 0.90
0.0
0 in EXISTING
HOUSE_
Covered
170.0 0.72
t
0.0
0 in EXISTING
HOUSE
FENESTRATION
SURFACES
SC
Act
Glass
# Type
Area Frame Div
U=Val
Azm Tilt
Only
Location/Comments
ZONE NAME EXISTING HOUSE
r 1.Wdw Front
(N)• 12.0 Metal No
0.94
0 90
0.88
EXISTING
HOUSE '
2 Wdw Front
(N) 8.0 Metal No
0.94
0 90
0.88
EXISTING
HOUSE
' 3 Wdw Left
(E) 16.0 Metal No
0:94
90 90
0.88
EXISTING
HOUSE '
4 Wdw Back
(S) 106:0 Metal No
0.94
180, 90
0.88
EXISTING
HOUSE
5 Wdw Back
(S) 40.0 Metal No
0.94
180 .90
0.88
EXISTING
HOUSE'
.6'Wdw Back
(S) 52.0 Metal No
0.94
180 -90
0.88
EXISTING
HOUSE'
'INTERIOR & EXTERIOR SHADING
# Type Interior Shade -Type
SC
Exterior
Shade
Type
SC_
1 Wdw Std
Drape
0.78`'
Standard
Bug,Screan
0.87
2 Wdw Std
Drape
0.78 --.Standard
Bug
Screen,
0.87
3'Wdw Std
Drape
0.78
Standard
BugScreen
0.87
4 Wdw Std
Drape
0.78
Standard
Bug -Screen
0.871.
„ 5 waw Std
Drape `
0.78
Standard
Bug
Screen
.0.87•
6 Wdw Std
Drape
0.78
Standard
Bug
Screen
0.87
COMPUTER METHOD SUMMARY
C -2R page 18,of 19
Project Name: GLENN KINUM - EXISTING j
Date: 11/19/1996
Documentation: INSU-FORM, INC. y
---------------------------------------------------------------------------
COMPLY 24 User 2655
OVERHANGS/SIDE FINS
--Window-- -----Overhang=----- ---Left Fin--- ---Right Fin--
# Type Ht Wd - Len Ht LExt RExt Dist Len,
Ht Dist Len Ht
1 Wdw 4. 0 ;' '3.0 2.0 0.1 2.0 2. 0
V
2'Wdw 4.0. 2.0. 2.0 0.1 2.0 2.0
3 Wdw 4.0 4.0 2.0 0.1 2.0 2.0
`
4 `Wdw 8.0 6. 0 .10.0 0.1 10.0 10.0
'
5 Wdw 6.8 6.0 10.0 0.1 10.0 10.0
6 Wdw 6.5 '4.0 10.0 0.1 10.0 10.0
THERMAL MASS Area Thick Heat
Inside Location
Type (sf) (in) Cap Cond Form 3 Reference
R -Val. Comments
ZONE NAME = EXISTING HOUSE;
Exposed Slab w360 .3.50 28 0.98 n/a
.0
Covered Slab 1440, '3.50 28 0.98 n/a'
2
HVAC SYSTEMS Minimum Distrib Type, Duct TStat.
System Type Efficiency and Location RVal Type •
Location/Comments-,
Furnace • 0.780 AFUE Ducts in Attic 2.1 SetBck
EXISTING HOUSE
PackAirCond 8.900 SEER Ducts in'Attic 2.1 SetBck
Water
No. Tank Ext.
WATER HEATING SYSTEMS Heater
in Energy Size +Insul
System Name s Distribution Type Type
Sys,Factor (gal) -R-Val
Std Gas 50 gal or Less Standard StorGas
1 0.53 50.0 12.0
. AFUE ,
WATER HEATER EQUIPMENT DETAIL /Rec' Rated -Stdby
Tank, Pilot
System Name System Type Eff Input
Loss R -Val Light
Std -Gas 50 gal -or Less DomesticHW 0.780 40000
0.040 0.0 0
SPECIAL FEATURES/REMARKS-
J POINT SYSTEM SUMMARY
P -2R page 19 of 19
Project Name: GLENN KINUM - EXISTING / ADDITION
Daae: 11/19/1996
Documentation:JNSU-FORM, INC.'
COMPLY 24 User
2655
BUILDING DATA
"
--------------
Conditioned Floor Area 1927
sqft
Number of
Stories i
Occupancy Type Single.Fam
Det
SCORE CARD
Measure
Points .
1. RoofInsulation
0.0501
(U -Value)
-5
2- Wall•Insulation
0.09,62
(U -Value)
-. -8
3. Raised Floor. Insulation _
0.0000
(U -Value)
3a. Controlled Vent Crawlspace',
0..0
(R -Value)
-> 0
r
4. Slab Edge Insulation
0.7680
.(f2 factor)
5. Infiltration
Standard
,0
' 6. Glass -.Heat Loss
0.93
13.8%
-4•
`
Sum 1-6
-17
7._' Fenestration Heat Gain
SC
,-
Orientation Area % Glass,
Open
Eff %
SER
• .----------- ------------
North 20'.0 1.0
---- Y
x 0.77 =
----- -----
0.8
a
2
East 56.0. 2.9
x 0.54 ='
,0.86.
1.6
0.47 2
'
South `, 190.0 9.9
x 0.33 _
3.2
0.87 -3
West 0.0 0.0
x .0. 00 =
0.0
0.00 4
Skylight 0.0 0.0
x 0.00
0.0,
0.00 0
8. Interior Thermal Mass
2.51'
1
9. Exterior Wall Mass
0.00
0 -
Sum 7-9
6.
10. Heating System
'°
'3
'Zonal Control: No
11. Cooling System
-8
12. Water Heating
-
0
Point .Total:
-22
Point Goal:
-23
i