Loading...
BCOM2014-1034,. 1 78-495 `'ALLE T'AMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: `Application Description Property Zoning: Application Valuation: I/ T4t!t 4 4 Qumz COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT BCOM2014-1034 . 46480 WASHINGTON STE 2 & 3 643020068 TENANT IMPROVEMENTS $150,000.00 Applicant: KRISTI HANSON ARCHITECTS 78-185 PAINTERS PATH WAY PALM DESERT, CA 92260 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.::CONV:140528 1253013133 � i Date:7i1��Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 1/14/2015 Owner: WASHINGTON 111 LTD 80618 DECLARATION AVE INDIO, CA 92253 Contractor: DENNISTHILL 78316 DESERT MOUNTAIN CIR BERMUDA DUNES, CA 92201 Llc. No.; :CONV:140528101253013133 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of th% or which this permit is issued. i I have and will maintain workers' compensation insurance, as required by Sectio -n3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. ylDa e: / Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF (COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned pro arrty for inspection purposes. Date"�_,:/5—Signature (Applicant or Agent'. , PAID DATE FINANCIAL .• 1• ' DESCRIPTION '`sACCOUNT Y '; QTY' AMOUNT_ ', ,PAID BSAS SB1473 FEE 101-0000-20306 0 $6.00 $0.00 _.'PAID BY ' 'METHOD , �e''`lRECEIPT# ",CHECK# CLTD BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA $6.00 $0.00 • DESCRIPTION '' • ' . e ' ACCOUNT w : ;QTY, -.,"AMOUNT ., `PAID PAID DATE DEVICES, ADDITIONAL 101-0000-42403 0 $24.20 $0.00 ' PAID BY `.' '° METHOD _ rt..' `: RECEIPT# ...•- '. ' -'CHECK # CLTD'BY, ' ``DESCRIPTION - ,,1 ' ` ACCOUNT, '� "QTY .AMOUNT. ,PAID , .-` : PAID DATE DEVICES, ADDITIONAL PC 101-0000-42600 0 $6.00 $0.00 _.T. PAID BY e` ;. s . •., :.: '� `.�' METHOD . '� RECEIPT # j CHECK # " CLTD BY -DESCRIPTION 3 _ ACCOUNT QTY, ^AMOUNT PAID = PAID DATE DEVICES, FIRST 20 X101-0000-42403 0 $24.17 $0.00 PAID BY ;1 `:; �.,METHOD RECEIPT # .' CHECK # ... CLTD BY .. ,�_:. f. , DESCRIPTIO N . , tom ';„;!,,ACCOUNT s# ” QTY 'AMOUNT PAID_ _. PAID DATE DEVICES, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 r'xPAID BY Y ... �. >h _. METHOD t r :RECEIP„T#” CHECK# Total Paid for ELECTRICAL:. $78.54 $0.00 ` DESCRIP.TION; : �- ACCOUNT ; 'x QTY :# '.AMOUNT.w • PAID ' �.«; ' PAID DATE; CONDENSER/COMPRESSOR 101-0000-42402 0 $108.78 $0.00 �a PAID BY ` ' ' ''METHOD >: " 7 RECEIPT # ,CHECK #, ;CLTD BY DESCRIPTION ', » ; ' t'ACCOUNT ` QTY; ,'� AMOUNT PAID : PAID DATE CONDENSER/COMPRESSOR PC 101-0000-42600 0� $72.51 $0.00 _ ,, r PAID BY ` . _ F METHOD ' " ' RECEIPT# ,CHECK # `F CLTD BY, "DESCRIPTION ��� � = p,� ����':A000UNT��;, ." r QTY. r'` AMOUNT , r `a% ;:PAID ; f�. ,, PAID DATE FURNACE 101-0000-42402 0 $108.78 $0.00 PAID BY,, i `METHOD, , a:. :: RECEIPT #" CHECK # CLTD BY �DESCRIP.TION '° u x: - .... :... .. r... ... .. FACCOUNT :r , ..... 1, R-. -. -.�. 'QTY �9.., F_ a AMMOUNT" +_t (PAID "ti PAID DATE, FURNACE PC 101-0000-42600 0 $72.51 $0.00 r` ft c ue PAID BYRECEIPT # -. • _ CHECK ,# A `,� CLTD By.,., 1 Total Paid forMECHANICAL: $362.58 $0.00 �t DESCRIPTION ACCOUNT , , ' tr QTY ;a AMOUNT.,.. ,_ PAID "tet PAID DATE WATER SYSTEM INST/ALT/REP . •101-0000-42401 0 $12.09 $0.00 , METHOD -RECEIPT # C HECK # ' _ CLTD BY ' 'DESCRIPTION �: Y ACCOUNT QTY N.` ' AMO T PAID , PAI.D';DATE WATER SYSTEM INST/ALT/REP PC, 101-0000-42600 0 $12.09 $0.00 ,. PAID BY ��a. ,»`n . . , :METHOD , RECEIPT # ' ;: CHECK #, . CLTD BY;, { Total Paid for PLUMBING FEES: $24.18 $0.00 •DESCRIPTION ' ACCOUNT CITY.'- " AMOUNT 'PAID PAID DATE" REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $174.00. $0.00 PAID. BY F " 'V ' METHOD- �q ,",RECEIPT# ` ''` •CHECK #, x:�` CLTD BY `DESCRIPTION _ `'' ACCOUNT :.,QTY; .. 'AMOUNT.'. , . - :"' •. 'PAID . '"i, PAID DATE. REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 • $139.20 $0.00 PAID BY '`'' ' - METHOD _ , RECEIPT # , "CHECK #,::1. ••.•CL DBY .. 'DESCRIP,TION ,a ACCOUNT:., ;; , 'QTY. AMOUNT PAID , " PAID DATE REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $0.00 t '? PAID BY Y : , . • a METHOD .. ,r..,:. ,... ,. _RECEIPT'CHECK # `. CLTD BY a,. DESCRIPTION i'.' - .J' ACCOUNT ;QTY' i AMOUNT' "PAID' PAID.DATE REMODEL, FIRST 500 SF PC 101-0000-42600 011. $134.88 $0.00 :A yPAID BY} ": _ . METHOD ;,` RECEIPT# CHECK #= ,'CLTD BY Total Paid for REMODEL: $497.39, $0.00 � DESCRIPTION , ' .'. :ACCOUNT r' :QTY. _ AMOUNT ' e` PAID ` : PAID DATE SMI - COMMERCIAL 101-0000-20308 0 $42.00 $0.00 •4,PAIDBY, METHO s R ,d RECEIPT #{ ` CHECK # CLTD BY Total Paid forSTRONG MOTION INSTRUMENTATION SMI $42.00 $0.00 TOTALS:i 0.00 Description: TENANT IMPROVEMENTS Type: BUILDING, COMMERCIAL Subtype: REMODEL Status: APPROVED Applied: 10/29/2014 MFA Approved: 1/14/2015 JJO Parcel No: 643020068 Site Address: 46480 WASHINGTON STE 2 & 3 LA QUINTACA 92253 Subdivision: TR 32683 Block: Lot: 2 issued:, CHRONOLOGY Fin Valuation: $10,000.00 ...�Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 IT Details: TENANT IMPROVEMENT NEXT LEVEL FITNESS 3 UNITS, FIT, IN 42, PERSONAL TRAINING AND BOOT CAMP. ADD NEW PARTIATION WALLS OFFICE AND LOBBY AREA. ADDITIONAL SITES Printed: Wednesday, January 14, 2015 10:03:02 AM 1of4 C9?w.'YSTFMS CHRONOLOGY 10 COMPLETION D IT SITE & FLOOR PLAN FOR ASSESSOR RECEIVED AT FRONT. COUNTER BY PJ. NOTE KAY HENSEL 1/9/2015 1/9/2015 SITEAND FLOOR PLAN WAS TO GO TO JAY WUU. DELIVERD TO STEVEN CORNER OF KRISTI HANSON ARCHIECTS 760 -776 - 4068 BROUGHT IN FIRE DEPT. APPROVAL PUT IN FOLDER. NOTE PHILIPJUAREZ 1/8/2015 1/8/2015 ALSO BROUGHT IN SITE AND FLOOR PLAN FOR PLANNING GIVEN TO JAY WUU. PLAN CHECK PICKED UP KAY HENSEL 11/19/2014 11/19/2014 CALLED STEVE CORNER TO INFORM HIM PLANS READY TO TELEPHONE CALL JIM JOHNSON '1/14/2015 1/14/2015 ISSUE CONDITIONS Printed: Wednesday, January 14, 2015 10:03:02 AM 1of4 C9?w.'YSTFMS FINANCIAL INFORMATION T, PAID DATE, CHECK # [SLTD' ,­',D1ESCRIPTION*.­ +_QTV:,AMOUNT'RECEIPT-.#' METHOD. i -PAID BT,,,.1-'i, x. 71w 'BY BSAS SB1473 FEE .101-0000-20306 0 $6.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $6.00 $0.00 BSA: - DEVICES, ADDITIONAL CONTACTS 0 $24.20 $0.00 ''-,V� ; Cl��§TAC [_'i DEVICES, ADDITIONAL PHONE 0 :EMAIL,'b6FEss $0.00 PC APPLICANT KRISTI HANSON ARCHITECTS 78-185 PAINTERS PATH PALM DESERT CA 92260 -DEVICES, FIRST 20 101-0000-42403 WAY $24.17 _$0.00 CONTRACTOR DENNISTHAL 78316 DESERT BERMUDA CA 92201 $0.00 MOUNTAIN CIR DUNES Total Paid for ELECTRICAL: $78.54 $0.00, CONDENSER/COMPRES 101-0000-42402 0 $108.78 OWNER WASHINGTON 111 LTD- 80618 DECLARATION INDIO CA 92253 SOR AVE FINANCIAL INFORMATION T, PAID DATE, CHECK # [SLTD' ,­',D1ESCRIPTION*.­ +_QTV:,AMOUNT'RECEIPT-.#' METHOD. i -PAID BT,,,.1-'i, x. 71w 'BY BSAS SB1473 FEE .101-0000-20306 0 $6.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $6.00 $0.00 BSA: - DEVICES, ADDITIONAL 101-0000-42403 - 0 $24.20 $0.00 DEVICES, ADDITIONAL 101-0000-42600 ~ 0 $6.00 $0.00 PC -DEVICES, FIRST 20 101-0000-42403 0 $24.17 _$0.00 DEVICES, FIRST 20 PC 101-0000-42600 0, $24.17 $0.00 Total Paid for ELECTRICAL: $78.54 $0.00, CONDENSER/COMPRES 101-0000-42402 0 $108.78 $0.00 SOR CONDENSER/COMPRES 101-0000-42600 0 $72.51 $0.00 SOR PC FURNACE 101-0000-42402 0 $108.78 $0.00 FURNACE PC 101-0000-42600 0 1 $72.51 $0.00 Total Paid forMECHANICAL: $362.58 $0.00 W ATER SYSTEM -T -10 1-0000-42401 0 $12.09 $0.00 INST/ALT/REP Printed: Wednesday, January 14, 2015 10:03:02 AM 2 of 4 CRWYSTFAAS � �.;'DESCRIPInON.,- ,;-ACCOUNT PARENT PROJECTS PAID DATE' -RECEIPT#, -,�HECK­#", 'METHOD"l PAID CLTD REVIEWS ,:-PAID DATE WATER SYSTEM 101-0000-42600 0 $12.09 $0.00 REVISIONS REQUIRED CORRECTIONS 1ST PLAN CHECK CORRECTIONS BUCKET INST/ALT/REP PC PLANNING PLANNING 10/29/2014 11/12/2014 10/31/2014 ASSIGNED Total Paid forPLUMBING FEES: $24.18 '$0.00 REMODEL, EA 101-0000-42400 0 $174.00 $0.00 ADDITIONAL 500 SF PER LQMC, HEALTH CLUBS 5,000 SQ. FT. FLOOR PLASSIGNMENT JAY WUU 10/31/2014 11/3/2014 11/3/2014 REMODEL, EA 101-0000-42600 0 $139.20 $0.00' PLANS APPROVED. PENDING FIRE AND PLANNING ADDITIONAL 500 SF PC - 12/5/2014 12/19/2014 12/S/2014 APPROVED APPROVED DEPT APPROVAL. MUP FROM PLANNING DEPT REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31* $0.00 -v- REMODEL, FIRST 500 SF Total Paid forREMODEL: $497.39 $0.00 SMI - COMMERCIAL 101-0000-20308 FO $42.00, $0.00 7_7 Total Paid forSTRONG MOTION INSTRUMENTATION SMV $42.00, .$0.00 9, INSPECTIONS I . ' Printed: Wednesday, January 14,ZOlS1Ol8:02AIM 3of4 PARENT PROJECTS RETURNED REVIEWS DATE NON-STRUCTURAL BUILDING 10/29/2014 11/12/2014 10/29/2014 REVISIONS REQUIRED CORRECTIONS 1ST PLAN CHECK CORRECTIONS BUCKET PLANNING PLANNING 10/29/2014 11/12/2014 10/31/2014 ASSIGNED BUCKET PER LQMC, HEALTH CLUBS 5,000 SQ. FT. FLOOR PLASSIGNMENT JAY WUU 10/31/2014 11/3/2014 11/3/2014 REVISIONS REQUIRED WASH PARK STE 2 & 3 AR EA OR LESS REQUIRE MINOR USE PERMIT PLANS APPROVED. PENDING FIRE AND PLANNING NON-STRUCTURAL 'JIM JOHNSON 12/5/2014 12/19/2014 12/S/2014 APPROVED APPROVED DEPT APPROVAL. MUP FROM PLANNING DEPT . ' Printed: Wednesday, January 14,ZOlS1Ol8:02AIM 3of4 • a 'TQ•..I fp �C�`b�OF•Tt�'�� PLANNING I JAY WUU 11/13/2015 I^1/28/2015 I 1/14/2015 I READY FOR APPROVAL I APPROVED I BOND INFORMATION Printed: Wednesday, January. 14, 2015 10:03:02 AM 4 of 4 lySTFMS \� C .. - City. 6 � La, Quin' to ' T Building a Safety Division P.O. Box 1504,78-495 Calle Tampico ' -3.Quip6, CA 92253 -'(760) 777-7012 Building Permit Application and Tracking Sheet - " Permit # Project,Addmss:-- 14 LARC) �^ Owner's Name: 4 r A- P. Number. (�.�-020 - OZ�1 �.SvT�S Z J Address: �. O \ i2 iption: City, ST, Zip: ` l�\Dl O �#iR Ck � C) :D tJ?alj "1 Telephone: `1bb_t --� :r.rc;'�Y `•w rAddre wp "OO CI�C.L��- P •ectDescription: . p:pv�&, CA G1Z.Z0 '7T•2--(10zCX0 • : S(o ,O Lie. #: Engn, Designer N Address: City., ST, Zip:�"� T « q Z Telephone: -y fo O--TZIo_ 44.0 to State Lic. KConstruction Type_:. %J, -NS Occupancy: Project type (circle one): New Add', Alter Repair Demo Sq. Ft.: Z� #Stories: C # Unit: Name of Contact Person: �� � Zl�l l Telephone # of Contact Person: 'Z 6 a'— 'T'7 - f-10 is 8 Estimated Value of Project: 150 u # Submittal Req'd APPLICANT: DO NOT WRITE BELOW THIS LINE Recd TRACKING PERMIT FEES Plan Sets a Plan Check submitted �t�/� item Amount Structural Calm Reviewed, ready fo corrections " Plan Check Deposit, . Truss Calcs. Called Contact P oa Plan Check Balance Title 24 Calm Plans picked up ` Construction Flood plain plan Plans resubmitted ( k Mechaliical Grading plan ZT'! Review, ready for cormetio /cssue Electrical Subcontactor List Called Contact Person Plumbing • Grant Deed Plans picked up S.M,I, H.O.A. Approval Plans resubmitted' Grading IN HOUSE:- '•° Review, ready for corrections/issue Developer Impact Fee Planning Approval. Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue • ^ ` School Fees • ,y 1 ' '' IP F Totaermit ees 010 laid 1, I�gNSY . ISSUE �NOtn W(((' 6r4.� AQ0 819A�5'1 P( . W P(�e i►wt j Po "' i�IPl2oU�- v P , RIVERSIDE COU FIRE DEQAAR'I`MEI�i"I` IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montabas Rd., Ste. #201, Palm Desert, CA 92211-4131 • Phone (760) 863-8886 • Fax (760) 863-7072 www.rvcfire.org PROUDLY SERVING THE January 7 2015 ry UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: Kristl Hanson 72185 Painters Path Suite A BANNING _ Palm Desert, CA 92260 BEAUMONT CALI M ESA RE: TENANT IMPROVEMENT PLAN CHECK -Non Structural CANYON LAKE LAQ-15-TI-001 Next Level Fitness 46480 Washington St. Suite 2&3 La Quinta, CA COACHELLA DESERT HOT SPRINGS You have been issued a release for a tenant improvement on an existing building. THIS IS NOT AN EASTVALE OCCUPANCY PERMIT. INDIAN WELLS It is prohibited to use/processor store any materials in this occupancy that would classify it as an INDIO "H" occupancy per. Sec. 307 of the 2013 CBC. LAKE ELSINORE THE FOLLOWING CONDITIONS MUST BE MET PRIOR TO INSPECTION: LA QUINTA MENIFEE Install door hardware and exit signs as per Chapter 10 of the 2013 CBC. MORENO VALLEY A minimum 2AIOBC Fire Extinguisher; (State Fire Marshal Approved) must be mounted in a PALM DESERT visible location within 75' walking distance from any point in your building or suite. Fire PERRIS extinguishers can be installed by a licensed extinguisher company with a State Fire Marshal service RANCHO MIRAGE tag attached to the extinguisher, or purchased from a retail store with a sales receipt attached. A licensed fire extinguisher company must service extinguisher yearly. RUBIDOUx CSD SAN JACINTO All breakers must be labeled and a clearance. of 36 inches must be maintained around the panel at all times. TEMECULA WILDOMAR A durable sign stating "This door to remain unlocked when building is occupied" shall be placed on or adjacent to the front exit door. The sign shall be in letters not less than one inch high on a contrasting background: BOARD OF SUPERVISORS: Display street numbers in a prominent location on the address side of building(s) and rear access if applicable. All addressing must be legible, of a contrasting color with the background and BOB BUSTER DISTRICT 1 adequately illuminated to be visible from the street at all hours. All lettering q Y � g shall be to Architectural Standards. JOHN TAVAGLIONE t' DISTRICT 2 Provide key(s) to the tenant space for inclusion in the main building Knox Box.. Key(s) shall have JEFF STONE durable and legible tags affixed for identifcation of.the correlating tenants ace. Ke (s) shall be DISTRICT 3 provided at time of final inspection.- nspection.JOHN JOHNBENOIT DISTRICT 4 As it may be necessary to maintain proper fire sprinkler protection due to constructions changes, fire MARION ASHLEY sprinkler system plans for the tenant improvement area may be required to be submitted to the Fire DISTRICT 5 Department for review: A five year sprinkler service and certification for the existing fire sprinkler system is required per Title 19. A licensed C-16 contractor must complete the servicing and certification. Documentation of completed work must be submitted to the appropriate Fire Protection Planning office. The maintenance records for the fire sprinkler system must be available on-site for review by field Inspector/personnel. The existing fire alarm system shall be modified to provide proper coverage as required by the California Building Code, California Fire Code and adopted standards. A C-10 licensed contractor must submit plans to our office for review and approval prior to installation. Applicable room door(s) shall be posted "ELECTRICAL", "FACP", "FIRE RISER" AND "ROOF ACCESS" on the outside of the door so it is visible and in a contrasting color. Nothing in our review shall be construed as encompassing structural integrity. Review of this plan does not authorize or approve any omission or deviation from all applicable regulations. Final approval is subject to field inspection. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. A re- inspection fee will be required if more than one (1) inspection is necessary. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760) 863 8886. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering Staff at (760) 863 8886. - Sincerely, Fire Safety Specialist. r s BUILDING ENERGY ANALYSfS REPORT PROJECT: Next Level Fitness Tenant Improvement 46-480. Washington Park Building, Suite 2 & 3 -La Quinta, CA 92253. Project Designer:. Kristi Hanson, Architects, Inc. 72-185 Painters Path, Suite A Palm Desert, CA 92260 (760) 776-4068 Report Prepared by: Tim Scott Scott Design and Title 24,,Inc, 77085 Michigan Drive Palm Desert, CA 92211 (760) 200-4780 Job Number: '�ECEIVED t `Date: CITY eUit UINTA 10/27/2014 R[q�It�T. FOR O �'� 'HENT The EnergyPro computer program has been used to perform the calculations summarized ink his complia ce r port. This rograpproval and is • authorized by the California Energy Commission for use with both the Residential and Nonresidenti� 1 u' ding En rgy Efficiency Stand rds. v,v1� : B K" This program developed by EnergySoft, LLC - www.energysoft..c =- EnergyPro 6.3 b" EnergySoft User Number: 6712. IO: /. 4 PERFORMANCE CERTIFICATE OF COMPLIANCE (Part 1 of 3) PERF -1C Project Name Date Next Level Fitness Tenant Improvement 10/27/2014 Project Address Climate Zone Total Cond. Floor Area Addition Floor Area 46-480 Washington Park Building, Suite 2 & 3 La CA Climate Zone 157 3,942 n/a GENERAL INFORMATION Building Type: m Nonresidential ❑ High -Rise Residential ❑ Hotel/Motel Guest Room ❑ Relocatable - indicate ❑ specific climate zone ❑ all climates Phase of Construction: ❑ New Construction ❑ Addition ❑ Alteration STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Name Tim Scott Signature Company Scott Design and Title 24, Inc, Date 102712014 Address 77085 Michigan Drive Phone (760) 200-4780 City/State/Zip Palm Desert, CA 92211 The Principal Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the energy efficiency requirements contained in sections 110.0, 116.0 through 118.0, and 140.0 through 149.0 of Title 24, Part 6. Please check one: ENV. LTG. MECH. I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to ❑ ❑ ❑ sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section ❑ ❑ ❑ 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document ❑ ❑ ❑ because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. Principal Envelope Designer Name Signature Company Envelope Compliance Not /n The Scope Of This Document Date Address License # City/State/Zip Phone Principal Mechanical Designer Name Tim Scott Signature Company Scott Design and Title 24, Inc. Date 10/27/14 Address 77-085 Michigan Drive License # City/State/Zip Palm Desert, Ca 92211 ' Phone (760) 200-4780 Principal Lighting Designer %l Name Kristi Hanson Signature I Company Kristi Hanson, Architects, Inc. ID.at t Address 72-185 Painters Path, Suite A B LIc 413 I_ DEPT City/State/Zip Palm Desert, CA 92260 Phon'e�(760:747 68 A" n- - k INSTRUCTIONS TO APPLICANT COMPLIANCE & WORKSHEETS (check box if worksheets a'rei)ncluded)--r 1 r. t ❑ ENV -01 Certificate of Compliance. Required on plans. m MCH -01 Certificate of Compliance. Required on plans. LTI-01 Certificate of Compliance. Required on plans. 10 MCH -02 HVAC AIANater Side Requirements. m LTI-02 Lighting Controls Credit Worksheet. m MCH -03 MechanicalR/entilation_and Reheat.By ❑ LTI-03 Indoor Lighting Power Allowance. 12 MCH -08 Mechanic! al-Equipment.D.etailt EnergyPro 6.3 by EnergySoft User Number: 6712 RunCode: 201410-27715:22:58 /D: Page 3 of 37 PERFORMANCE CERTIFICATE OF COMPLIANCE (Part 2 of 3) PERF -1C„ Project Name Date .Next Level -Fitness Tenant Improvement - 10/27/2014 ANNUAL TDV ENERGY. USE SUMMARY. kBtu/s ft- r Standard Proposed Compliance Energy Component Design Design Margin ' Space Heating Space Cooling - - Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process Process Lighting TOTALS 3.08 2.58 0.50 467.98 477.41 -9.43 161.45 80.22 81.23 0.00 0.00 0.00 0.00 0.00 0.00 142.04 148.60 -6.56 61.65 60.15 1.50 46.85 46.85 = 0.00 0.00 0.00 0.00 • 0.00 0.00 0.00 883.04 815.80 67.25 Heating .v_ (NE) `` Cooling (SE) 650 ., Fans Heat Rej y Pumps -rt, DHWtir-- Lighting-.- -- --/ -- Receptacle'- ProcessA Process Ltg .,.;, f ,4- , •I' - - Percent better than Standard 7.6 7.6 94. excludiriprocess) BUILDING COMPLIES GENERAL INFORMATION Building Orientation (NSM 315 deg Conditioned: Floor Area, 3,942 sqft. Number of Stories 1. Unconditioned Floor Area o sqft. , Number of Systems 3 Conditioned Footprint Area 1 3,942 sqft. Number of Zones 1 3 - Natural Gas Available On 'Site j Yes Orientation Gross'Area Glazinq Area Glazinq Ratio Front Elevation Left Elevation . Rear Elevation Right Elevation Total Roof (NW) 650 (NE) `` 685 (SE) 650 (SM 635 q94 sqft. sqft. sqft. sqft. sqft. sqft..` 336 0 84 112 512 `o sqft. sqft. sqft. sqft. sqft. sqft. 51.7 0.0% 9.8 17.6% 19.5916 0.0 "Standard "- Proposed Prescriptive Values for Prescriptive Lighting Power Density _ - 1.006W/sgft`' 0.841 W/syftt. Comparison only. See LTI-01 for allowed LPD. Remarks: CITY OF LA QUINTA BUILDING & SAFETY DEPT. • �� - - . APPROVE® tz CONSTRUCTION - ' DATE • �_ BY EnergyPro 6.3 by EnergySoft . User Number.- 6712 Run Code: 2014-10-27715:22:58 ID: i ge. of 37 4 PERFORMANCE CERTIFICATE OF COMPLIANCE (Part 3 of 3) PERF -1C Project Name Next Level Fitness Tenant Improvement I Date 10/27/2014 ZONE INFORMATION System Name Zone Name Occupancy Type FloorInst. Area LPD s ft. /s ' Ctrl. Allowed LPD Proc. Credits Area Tailored Loads /s 2 /s 3 /s ° W/s HVAC 1 Boot Camp Exercise, Gymnasium 1,315 0.867 HVAC 2 Personal Training Exercise, Gymnasium 1,169 0.760 0.024 HVAC 3 Fit in 42 Exercise, Gymnasium 1,458 0.918 0.018 Notes: 1. See LTI-01 2. See LTI-02 3. See LTI-03 4. See LTI-04 items marked with asterisk, see LTI-01 by others) (by others Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These Items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justifications, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Ir` I TV n f` I , I Ill nlntrn o DEP 1. 1 AFr _ r! r The exceptional features listed in this performance approach application have specifically been reviewed. Adbgtiat Ni a j'us. ISc'a{ aoNnd documentation for their use have been provided by the applicant. Authorized Signature or Stamp LDATE:: BY EnergyPro 6.3 by EnergySoft User Number: 6712 RunCode: 201410-27715:22:58 STA- CALIFORNIA IN R LIGHTING CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS NRCC-LTI-01-E Indoor Lighting (Page 1 of 5) Project Name: Next Level Fitness Tenant Improvement Date Prepared: 10/27/2014 Climate Zone: 15 Conditioned Floor Area : 3,942 YES NO FORM TITLE YES NRCC-LIT-01-E Certificate of Compliance. All Pages required on plans for all submittals. Unconditioned Floor Area : 0 Lighting Controls, Certificate of Compliance, and PAF Calculation. All Pages required on plans for all submittals. General Information Indoor Lighting Power Allowance NO NRCC-LIT-04-E Tailored Method Worksheets NO I NRCC-LIT-05-E Line Voltage Track Lighting Worksheets Building Type: ❑ Schools El Nonresidential ❑ Relocatable Public Schools ❑ 0 High -Rise Residential Conditioned Spaces ❑ ❑ Hotel/Motel Unconditioned Spaces Phase of Construction: ❑ New Construction ❑ Addition ❑. Alteration Method of Compliance: ❑ Complete Building El Area Category ❑ Tailored LIGHTING COMPLIANCE DOCUMENTS (select yes for each document included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance documents, refer to the Nonresidential Manual published by the California Energy Commission. YES NO FORM TITLE YES NRCC-LIT-01-E Certificate of Compliance. All Pages required on plans for all submittals. YES NRCC-LIT-02-E Lighting Controls, Certificate of Compliance, and PAF Calculation. All Pages required on plans for all submittals. NO NRCC-LIT-03-E Indoor Lighting Power Allowance NO NRCC-LIT-04-E Tailored Method Worksheets NO I NRCC-LIT-05-E Line Voltage Track Lighting Worksheets p ummary of Altowed]Lighting Power U e- oAitione�d and Cncon'ditioned space Lighting must not be combined for compliance p In oor Lighting Power for Conditioned Spaces Indoor Lighting Power for Unconditioned Spaces n U Z Watts Watts 3,367 0 O go O Installed Lighting Installed Lighting NRCC-LTI-01-E, age 4 + NRCC-LTI O1 E, age 4 + Oo Z4®D PORTABLE ONLY FOR OFFICES + K nNRCC-LTI-01-E, page 3 n Minus Lighting Control Credits M 54 Minus Lighting Control Credits 0 "� C NRCC-LTI-02-E, page 2 NRCC-LTI-02-E, page 2 4. Z U z Adjusted Installed Lighting Power = 3,313 Adjusted Installed Lighting Power _ 0 (row 1 plus row 2 minus row 3) (row 1 minus row 3) 90 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STA CALIFORNIA . INR LIGHTING CEC-NRCC-LTI-01-E Revised 06/14 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS NRCC-LTI-01-E Indoor Lighting (Page 2 of 5) Project Name: Next Level Fitness Tenant Improvement Date Prepared: 10/27/2014 Declaration of Required Installation Certificates - Declare by selecting yes for all Installation Certificates that will be submitted. (Retain copies and verify forms are S. Complies ONLY if Installed 5 Allowed Complies ONLY if Installed<_ Allowed Form/Title 6. Allowed Lighting Power Conditioned NRCC-LTI-03-E, page 1 3,313 Allowed Lighting Power Unconditioned NRCC-LTI-03-E, page 1 .0 NRCI-LTI-02-E - Must be submitted for a lighting control system, or for an Energy Management Control System (EMCS), Declaration of Required Installation Certificates - Declare by selecting yes for all Installation Certificates that will be submitted. (Retain copies and verify forms are completed and signed.) YES NO Form/Title NRCI-LTI-01-E - Must be submitted for all buildings ❑ Field'Inspector¢' s LTI-03-A - Must be submitted for automatic daylight controls. NRCI-LTI-02-E - Must be submitted for a lighting control system, or for an Energy Management Control System (EMCS), ❑ Field- Inspector - N rN+Rj 1-04-A - Must be submitted for demand responsive lighting controls. ❑ Field Inspector to be recognized for compliance. K NRCI-LTI-03-E - Must be submitted for a line -voltage track lighting integral current limiter, or for a supplementary ❑ Field Inspector ' overcurrent protection panel used to energize only line -voltage track lighting, to be recognized for compliance. NRCI-LTI-04-E - Must be submitted for two interlocked systems serving an auditorium, a convention center, a ❑ Field Inspector conference room, a multipurpose room, or a theater to be recognized for compliance. NRCI-LTI-05-E - Must be submitted for a Power Adjustment Factor (PAF) to be recognized for compliance. ❑ Field Inspector 4 NRCI-LTI-06-E - Must be submitted for additional wattage installed in a video conferencing studio to be recognized for ❑ Field Inspector compliance. Decide ation of Require -_Ce -ificates of Acceptance - Declare by checking all of the Certificates of Acceptance that will, be submitted. (Retain copies and verify forms are' comdlelI and sfgned.�j YES I I N©7 Fo ry it!le Z NRCA—'�L 1-02-A - Must be submitted for occupancy sensors and automatic time switch controls. ❑ Field. Inspector LTI-03-A - Must be submitted for automatic daylight controls. ❑ Field Inspector rN+Rj 1-04-A - Must be submitted for demand responsive lighting controls. ❑ Field Inspector Z ° d 0 Z CA ards - 2013 Nonresidential Compliance June 2014 STA CALIFORNIA IN R LIGHTING CEC-NRCC-LTI-01-E (Revised 06/14) CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS Indoor Lighting Project Name: Next Level Fitness Tenant Improvement Date Prepared: 10/27/2014 NIA ENERGY COMMISSION N RCC-LTI-01-E (Page 3 of 5) A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power listed on this Lighting Schedule is only for: ® CONDITIONED SPACE ❑ UNCONDITIONED SPACE A. INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST ❑ The actual indoor lighting power listed on this page and on the next page includes all installed permanent and planned portable lighting systems. ❑ When Complete Building Method is used for compliance, list each different type of luminaire on separate lines. ❑ When Area Category Method or Tailored Method is used for compliance, list each different type of luminaire by each different function area on separate lines ❑ Also include track lighting in schedule, and submit the track lighting compliance form (NRCC-LTI-05-E) when line -voltage track lighting is installed. B. Installed Portable Luminaires in Offices — Exception to Section 140.6(a) ❑ This section shall be filled out ONLY for portable luminaires in offices (As defined in §100.1). All other planned portable luminaires shall be documented on next page of this compliance form. ❑ This section is used to determine if greater than 0.3 watts of portable lighting is planned for any office ❑ Fill out a separate line for each different office. Small offices that are typical (having the same general and portable lighting) may be grouped together. This allowance shall not be traded between offices having different lighting systems. Office Portable Luminaire Office Installed Portable Luminaire Watts Per Square Office Location Field Schedule Foot Inspector O A B C D E F G H I J m Installed 0 3 portable O v+ M Watts If 1`5 0.3, Identify Office area in which � C mplete ip ion 3 5- T. luminaire watts in this ? o, 5; „ per square enter zero; E x G these portable luminaires are v T, �oofnifa�ire=Desc �}-� n E Qrnit�u`r Watts `�° ° 0 M foot if F 0.3, installed (i.e., , under c�.abiriet, mounted d'Zct/di ect per Luminaire office (B x C) (D / E) > (F 0.3) co —i D ❑ ❑ c.: m ❑ ❑ —� C 1 ❑ ❑ O t❑ — 1-71 ❑ ❑ ° Enter sum total of all pages into NRCC- o a Ins a e portable luminaire watts that are greater than 0.3 watts per square foot per office: LTI-01-E; Page 1 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 0 1 w _ I O o ZJ w tw U U Iv Fn a Ln E Z � 0 I { 0 0 )F LA QUIN a & SAFETY DE :)ROVED ONSTRUCTION BY. V O CL) C w C CL E 0 u m c w N C O Z M 0 ry S c a> Ln E Z a) OO LL IZ E Ln Z C (0 cc C LU Ln D C In I N w U S �Q CD O v LL zea J N -j ¢_irU ❑ ❑ 1,x- o_ w LL O C a) Z ❑ LL J O Q F W HQ L OE,U�� U U v_ oA � m I K x77 ti O Z t � O a 'o PzW U c a` )F LA QUIN a & SAFETY DE :)ROVED ONSTRUCTION BY. V O CL) C w C CL E 0 u m c w N C O Z M 0 ry S LL w CL C v LL ❑ ❑ ❑ ❑ ❑ ❑ ❑ IT ❑ u O c � 3 � v C H W C v w> j a ry O M 1`0 N N (0 N Co y 4- w C7 0 v C C O a' V JC + 'm C E �+ E T m y LU E C7 (7 0 LL N N O N VU1_ N J L a Y 2 a) a> U U x x C w W W w Z Total Installed Watts in this area N N O (CxE) v r rn M M Number J Q W Luminaires O H M N M w Y .'a 3 According to ❑ 1:1 El [I❑ [I❑ ❑ ❑ a W m (U 4130.0(c) 3 CEC Default p vGi ® ® 1101111 ❑ ❑ ❑ 0 from NAB W Q z N W Z Z Watts per — Luminaire o O Cu W a N z O N W C m LL O a � � O .0 ^ CN C N � aJ w c v J 5 v w 0 m w C 0 v u E w m H H 2 aE —p@�"�/ U N L w E E f0 v a) ( �i r v U U -# a t z E 6° o o BUILDIN U - ao _:3 _:3 = J m EL LL AP J LL FOR p v Og DA rE Z 2e E wall N L Q Jo amen] U X X x N )F LA QUIN a & SAFETY DE :)ROVED ONSTRUCTION BY. V O CL) C w C CL E 0 u m c w N C O Z M 0 ry S MECHANICAL COMPLIANCE FORMS & WORKSHEETS (check box if worksheet is included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, refer to the 2013 Nonresidential Manual Note: The Enforcement Agency may require all forms to be incorporated onto the building plans. YES NO Form/Worksheet # Title ❑ ❑ NRCC-MCH-01-E (Part 1 of 3) Certificate of Compliance, Declaration. Required on plans for all submittals. ❑ ❑ NRCC-MCH-01-E (Part 2 of 3) Certificate of Compliance, Required Acceptance Tests (MCH -02A to 11A). Required on plans for all submittals. 0 ❑ NRCC-MCH-01-E (Part 3 of 3) Certificate of Compliance, Required Acceptance Tests (MCH -12A to 18A). Required on plans where applicable. ® ❑ NRCC-MCH-02-E (Part 1 of 2) Mechanical Dry Equipment Summary is required for all submittals with Central Air Systems. It is optional on plans. m ❑ NRCC-MCH-02-E (Part 2 of 2) Mechanical Wet Equipment Summary is required for all submittals with chilled water, hot water or condenser water systems. It is optional on plans. El ❑ NRCC-MCH-03-E Mechanical Ventilation and Reheat is required for all submittals with multiple zone heating and cooling systems. It is optional on plans. MECHANICAL HVAC ACCEPTANCE FORMS (check box for required forms) Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for HVAC systems. The designer is required to check the applicable boxes for all acceptance tests that apply and list oil equipment that requires an acceptance test. All equipment of the some type that requires a test, list the equipment description and the number of systems. Installing Contractor: The contractor who installed the equipment is responsible to either conduct the acceptance test them self or have a qualified entity run the test for them. If more than one person has responsibility for the acceptance testing, each person shall sign and submit the Certificate of Acceptance applicable to the portion of the construction or installation for which they are responsible. Enforceme t -Agency.• Ploncheck The7NRCC-MCH-01-E form is not considered a completed form and is not to be accepted by the building department unless the correct boxes are checked. Inspector - efobre occupancy periis jonted all newly installed process systems must be tested to ensure proper operations. Test a cription T Ci k02 MCH -03A MCH -04A MCH -05A MCH -06A MCH -07A MCH -08A MCH -09A MCH -10A MCH -11A Equipment # Qut oo Single Zone Air Economizer Demand Supply Fan Valve Leakage Supply Water Hydronic Automatic Requiring esI ing uis Z Unitary Distribution Controls Control VAV Test Temp. Reset System Demand Shed or Verifica io 1 Q G) Ducts Ve ntilation Variable Flow Control Z go (DCV) Control Carrier 5 0613—� O y M ® ❑ ❑ ❑ ❑ ❑ ❑ ❑ 13C ❑ ❑ ❑ ❑ ❑ ❑ 11 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Elp ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF*C0 RMECHAL SYSTEMS CEC-NRCC-E (Revised 06/14) CERTIFICATE OF COMPLIANCE Mechanical Systems Project Name: Next Level Fitness Tenant Improvement CALIFORNIA ENERGY COMMISP NRCC-MCH-01-E (Page 2 of 3) Date Prepared: 10/27/2014 MECHANICAL HVAC ACCEPTANCE FORMS (check box for required forms) Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for HVAC systems. The designer is required to check the applicable boxes for all acceptance tests that apply and list all equipment that requires an acceptance test. All equipment of the same type that requires a test, list the equipment description and the number of systems. Installing Contractor: The contractor who installed the equipment is responsible to either conduct the acceptance test them self or have a qualified entity run the test for them. if more than one person has responsibility for the acceptance testing, each person shall sign and submit the Certificate of Acceptance applicable to the portion of the construction or installation for which they are responsible. The following tests require a Enforcement Agency: Plancheck — The NRCC-MCH-01-E form is not considered a completed form and is. not to be accepted by the building department unless the correct boxes are checked. Inspector - Before occupancy permit is granted all newly installed process systems must be tested 4o ensure proper operations. Test Description MCH -12A MCH -13A MCH -14A MCH-1SA MCH -16A MCH -17A MCH -18A Equipment # of Fault Detection & Automatic Fault Distributed Energy Thermal Energy Supply Air Condenser Water ECMS Requiring Testing units Diagnostics for DX Detection & Storage DX AC Storage (TES) Temperature Reset Reset Controls or Verification Units Diagnostics for Air & Systems Systems Controls Zone Carrier 50EZ06(3 ❑ ❑ ❑ ❑ ❑ ❑ ' ❑' . ,. ❑: ❑ ❑ ❑ ❑ 0, ❑ 11 13 11 11' 13 Ell 0 0[3❑ ❑ ❑ ❑ ❑ M1 0, 0 ❑ El ❑ ❑ ❑ ❑ ❑ 7P — Oho ❑ 13 ❑ .❑ ❑ Lz�0T� PTI 2 MZ M CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STA CALIFORNIA INOWR LIGHTING— LIGHTING CONTROLS ! CEC-NRCC-LTI-02-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E Indoor Lighting - Lighting Controls (Pagel of 3) Project Name: Next Level Fitness Tenant Improvement Date Prepared: 10/27/2014 The NRCC-LTI-02-E shall be used to document all mandatory and prescriptive lighting controls that are applicable to the project. Mandatory Lighting Control Declaration Statements (Indicate if the measure applies by checking yes or no below.) YES NO Control Requirements Lighting shall be controlled by self-contained lighting control devices which are certified to the Energy Commission according to the Title 20 Appliance Efficiency Regulations in accordance with Section 110.9. Lighting shall be controlled by a lighting control a system or energy management control system in accordance with §110.9. An Installation Certificate shall be submitted in accordance with Section 130.4(b). One or more Track Lighting Integral Current Limiters shall be installed which have been certified to the Energy Commission in accordance with §110.9 and §130.0. Additionally, an Installation Certificate shall be submitted' in accordance with Section 130.4(b). A Track Lighting Supplementary Overcurrent Protection Panel shall be installed in accordance with Section 110.9 and Section 130.0. Additionally, an Installation Certificate shall be installed in accordance with Section 130.4(b). All lighting controls and equipment shall comply with the applicable requirements in §110.9 and shall be installed in accordance with the manufacturer's instructions in accordance with Section 130.1. All luminaires shall be functionally controlled with manually switched ON and OFF lighting controls in accordance with Section 130.1(a). General lighting shall be separately controlled from all other lighting systems in an area. Floor and wall display, window display, case display, ornamental, and special effects lighting shall each be separately controlled on circuits that are 20 amps or less. When track lighting is used, general, display, _ornamental, and special effects lighting shall each be separately controlled; in accordance with Section 130.1(a)4. Thegne�ral lighting of any enclosed area 100 square feet or larger, with a connected lighting load that exceeds 0.5 watts per square foot shall meet the multio-�! eMilhting control requirements in accordance with Section 130.1(b). insb. alt<d ndoor lighting shall be equipped with controls that meet the applicable Shut -OFF control requirements in Section 130.1(c). n v Z Z ffwg­MII Daylit Zones shall be controlled in accordance with the requirements in Section 130.1(d) and daylit zones are shown on the plans. C�g er in buildings larger than 10,000 square feet shall be capable of being automatically reduced in response to a Demand Responsive Signal in ncEdr - c with Section 130.1(e). organ occupancy permit is granted for a newly constructed building or area, or a new lighting system serving a building, area, or site is operated for O Z nh1n, e, indoor lighting controls serving the building, area, or site shall be certified as meeting the Acceptance Requirements for Code Compliance in aC-I& e with Section 130.4.(a). The controls required to meet the Acceptance Requirements include automatic daylight controls, automatic shut -OFF cont�s, and demand responsive controls. CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STA CALIFORNIA IN R LIGHTING — LIGHTING CONTROLS CEC-NRCC-LTI-02-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E Indoor Lighting - Lighting Controls (Page 2 of 3) Project Name: Next Level Fitness Tenant Improvement Date Prepared: 10/27/2014 A separate document must be filled out for Conditioned and Unconditioned Spaces. This page is used only for the following: El CONDITIONED SPACES ❑ UNCONDITIONED SPACES MANDATORY AND PRESCRIPTIVE INDOOR LIGHTING CONTROL SCHEDULE, PAF CALCULATION, and FIELD INSPECTION CHECKLIST PAF Credit Calculation 2 � n � rD D _T (D ;z Standards Complying. With 1 0 r 7 00 ni o " r) o X M .-r 7o n (D (D - a �• iv 7 o M - K Lighting Control Schedule. (✓ all that apply, or enter 'E' if Exempted) fl ° T = 0- m o A B C D E F G H I J K L M N O Type/ Description of Lighting Control (i.e.: occupancy sensor, # ,`O., b' L0; °; W; A W; Location in Building automatic time switch, of o 0 0 0 0 o dimmer, automatic daylight, Units ^ o a — N etc...) Personal Training Occ Sensor - <= 125 sgft 1 70 0.40 28 1 ❑ 1 ❑ Fit in 42 Occ Sensor - <= 125 sqft 64 0.40 26 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ I �_ 1:1❑ I Control Credit PAGE TOTAL (Sum of Column M): 54 II ®'D d5 qIq MULTIPLE PAGES ARE USED, ENTER SUM TOTAL OF Control Credit for all pages HERE (Sum of all Column M): 54 W X �D ' Enter Control Credit total 3jo D >r into NRCC-LTI-01-E; Page I C 17 1. 1. §13d.1' = Maxi�are—'a cora:t Is; §130.0(b) = Multi Level, §130.1(c) =Auto Shut -Off, §130.1(d) = Mandatory Daylight, • §130.1(e) = Demand Responsive, §140.6(d) = Additn l lightin^��r(6s irr a ed to earn a PAF, • §140.6(d) = Prescriptive Secondary Sidelit Daylight Controls. 2. Che?], k 'able, 1Z.6 -A fglcor. t Factor. PAFs shall not be traded between conditioned and unconditioned spaces. As a condition to earn a PAF, an Installation Certificate is also rq lred to be filled t�slg ed, and submitted. CA BuildingEner�ccieirc rStaAdaFds - 2013 Nonresidential Compliance June 2014 'STATE OF -CALIFORNIA HVAC SYSTEM REQUIREMENTS CEC+NRCC-MCH-02-E Revised 06/14 CERTIFICATE OF COMPLIANCE HVAC Dry System Requirements Profen"ame: Next Level Fitness Tenant Improvement Date Prepared: 10/27/2014 M), NRCC-MCH-02-E (Page 1 of 3) Equipment Tags and System Description' HVAC 1 1 HVAC 2 HVAC 3 MANDATORY MEASURES Heating Equipment Efficiency3 Cooling Equipment Efficiency3 HVAC or Heat Pump Thermostats Furnace Standby Loss Control Low leakage AHUs Ventilation Demand Control Ventilations Occupant Sensor Ventilation Contro16 Shutoff and Reset Controls' Outdoor Air and Exhaust Damper Control Isolation Zones Automatic Demand Shed Controls Economizer FDD Duct Insulation PRESCRIPTIVE MEASURES T-24 Sections Reference to the Requirements in the Contract DocumentS2 110.1 or 110.2(a) 110.1 or 110.2(a) 110.2(b), 110.2(c) 110.2(d) 110.2(f) 120.1(b) 120.1(c)4 120.1(c)5, 120.2(e)3 120.2(e) 120.2(f) 120.2(g) 120.2(h) 120.2(i) 120.4 Equipment is sized in conformance with 140.4(a.& b) Y Y Y 140.4(a&b) Supply Fan Pressure Control 140.4(c) Simultaneous Heat/Cool' 140:4(d) Economizer 140.4(e) Heat and Cool Air Supply Reset 140.4(f) Electric Resistance Heating9 140.4(8) Duct Leakage Sealing and Testing.10 140.4(1) Notes: 1. Provide equipment tags (e.g. AHU 1 to 10) and system description (e.g. Single Duct VAV reheat) as appropriate. Multiple units with common requirements can be grouped together. 2. Provide references to plans (i.e. Drawing Sheet Numbers) and/or specifications (including Section name/number and relevant paragraphs) where each requirement is specified. Enter "N/A" if the requirement is not applicable to this system. 3. The referenced plans and specifications must include all of the following information: equipment tag, equipment nominal capacity, Title 24 minimum efficiency requirements, and actual rated equipment efficiencies. Where multiple efficiency requirements are applicable (e.g. full- and part -load) include all. Where appliance standards apply (110.1), identify where equipment is required to be listed per Title 201601 et seq. 4. Identify where the ventilation requirements are documented for each'central HVAC system. Include references to both central unit schedules and sequences of operation. If one or more space is naturally ventilated identify where this is documented in the plans and specifications. Multiple zone central air systems must also provide a MCH -03-E form. 5. If one or more space has demand controlled ventilation identify where it is specified inGluding_t sensor specifications and the sequence of operation. TYLn�q ��- 6. If one or more space has occupant sensor ventilation control identify where itis specifie��d .ntclT OF�r�eey a'�idnAn 6ulLuSAFETY the sequence of operation Ell' DEPT. 7. If the system is DDC identify the sequences for the system start/stop, optimal stark, setback (if�dt ((If�equired) For all systems identify the specification for the thermostats and time clocks (if applicable);ORUCTTL08. Identify where the heating, cooling and deadband airflows are scheduledfor this system. Incluce to th�specification of the zone controls. Provide a MCH-03-Eform. I r14T�9. Enter N/A if there is no electric heating. If the system has electric heating indicate which exce92lie_s`_ 10. If duct leakage sealing and testing is required, a MCH -04-A form must be submitted. CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CAJJFORNIA MECH4WAL VENTILATION AND REHEAT CEC-NRCC- -03-E (Revised 06/14) • CERTIFICATE OF COMPLIANCE NRCC-MCH-03-E- Mechanical Ventilation & Reheat (Page 1 of 2) Project Name: Next Level Fitness Tenant Improvement Date Prepared: 10/27/2014 ACTUAL DESIGN INFO (FROM EQUIPMENT VAV Reheated Primary Air VAV Deadband SCHEDULES, ETC) AREA BASIS OCCUPANCY BASIS MINIMUM CFM Primary Air CFM A B C D E F G H I 1 K L M N 0 P Q R S T ND D Z < o^ Zci O T o^^ Divi = v ^ as ^ O Z 3 z ^ �_ z T Z 3 T 3 3 z T z Xa n O p 0 3 D r D x 33 n 0 N Z o 0;2 N �w D trp n O W OD z 0 o z zci o z ry < n T a _ D g 3 0 m 3 z< T p 3D 3 _0 n z v D z 0 3 X 3 n Z p v v n v K N3 vT3 Z Z O 0 Z nO �n O Z c) K 3^K 0 < o z 3 .0 Zz v ^ D D Z CF D Arn Boot C 1,315 0.50 658 21.9 10.0 219 658 Y Total 658 Persor 1,169 0.50 585 19.5 10.0 195 585 Y Total 585 Fit in 4 1,458 0.50 729 24.3 10.0 243 729 Y Total 729 Yellow shaded cells require user input. Remaining cells are protected and automatic B. The largest amount of primary air supplied by the terminal unit when it's operating in the cooling mode. C. The sm le� t a_mount of•primacy�upplied by the terminal unit in the deadband mode. D. The lar estyamount of primUryj air su • plied by the terminal unit when it's operating in the heating mode. E. A term i ai nit can be conti lle with DDC controls, or non -DDC controls. Each control category has different reheat limitations in code. F. Transf r it must� vld'ed w�r ( Required Ventilation Airflow (Column M) is greater than the Design Primary Deadband Airflow (Column C). H. Minim ventilat a -ate We S��ctidn §120.1. Table 120.1-A. 23 We J. Based number applicable or the greater of the expected number of occupants and 50'0 of the CBC occupant load for egress purposes for spaces without fixed seating. M. Ventilation Airflow) is the larger of the ventilation rates calculated on an AREA BASIS or OCCUPANCY BASIS (Column I or L) Requi e Ventilat 1 P�LrfldQ(Req'i�,ot N. O. This I mn idIRT-jesswwhiftertl the Design Primary Deadband Airflow complies or not. It compares the value in column M to the value in column C and column F. Desi . RRimary (—o�Vn�jA(rfjo i 9 50 for DDC, Design Primary Cooling Airflow * 0.30 for Non DDC. If the Design Primary Cooling Airflow is less than 300 cfm, then this is not applicable. P. Max' r%i of Cc P�.iv1 d Cgiuriin O. If the Design Primary Cooling Airflow is 300 cfm or less, then this is not applicable. Q. This o umn ide fieSwhg o not the Design Primary Reheat Airflow at the zone level, complies or not. It compares the value in column P to the value in column D. R. Des n Primary IAl .20 for DDC. Not applicable for Non -DDC zones or zones where Design Primary Cooling Airflow is is 300 cfm or less. S. Ma i um of C� a d(7l mn R. Not applicable if the Design Primary Cooling Airflow is 300 cfm or less. OF T. Thi c lumn id ifl t -r not the Design Primary Deadband Airflow at the zone level, complies or not. It compares the value in column S to the value in column C. CA - 2013 Nonresidential Compliance June 2014 • MECHANICAL EQUIPMENT DETAILS (Part 1 of 2) NRCC-MCH-08-E - Project Name Next Level Fitness Tenant Improvement Date 10/27/2014 CHILLER AND TOWER SUMMARY PUMPS Equipment Name T pe Q Efficiency Tons Pump O GPM BHP Control DHW I BOILER SUMMARY System Name Type Vol. Distribution Qty. Rated Input (Gals). Energy Factor Standby Loss Tank Ext. or RE or Pilot R -Value Status A O Smith ELJF-6 Small Storage Electric All Pipes Ins 4 5,120 6 0.92 n/a n/a New MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water Pump Hot Water Piping Length ft Control Qty. HP Type In Plenum Outside Buried Add '/2" Insulation ❑. CENTRAL SYSTEM RATINGS HEATING COOLING System Name Type Qty. Output Aux. kW Efficiency Output Efficiency Status Carrier 50EZ060 Packaged DX 3 57,000 0.0 7.70 HSPF 57,500 13.0 SEER/ 11.2 EER New D m C CENTRAL SY EM FAN WSJM Y SUPPLY FAN RETURN FAN stem en Fan Type Economizer Type CFM BHP CFM BHP Carrier SOEZ060Constant Volume No Economizer 1,650 0.40 none c D M, q rn o® — — m EnergyPro 6.3fbylEnergySoft ._Ute Number: 6712 Run Code: 201410-27T15:22:58 ID: Page 16 of 37 Now-, 03, °ld3Q u VlNInc m T m o m N Cu = a = DN Z�m m a 3 U c C m CD Z 0 w ° �, 3 Z D d T Z � 8 3— 31VG 4 cn 3 1D 3 cn S m C7 o o C � cy� ti D 1 L'Oj ic ~ m X A �?kl-rl cN �N A 11f18 Cl) a � : d Z ° m O• m T 3 ID <o (o <O rn N � 0 0 0 = D J J J YI m ° x _ a c N 3 D A N z m z -i m e m 3 � m o n � N o n J 4 A 0 o o N D ED V y H �J Ci � co 7 o�0 3 0 3 0 p o m x _ a c o ° m 0 3 3z z d N m CD d ' N m = O M N ❑ ❑ ❑ ❑ ❑ ❑ 1:11011:1 ❑ 11 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Fan Z A Cycles X ❑ ❑ ❑ ❑ ❑ ❑ 111111 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ECM 0 Motor ci n m � 3 O N n CD DO 5 o m O A O 00 I • • r� • • STATE OF CALIFORNIA WATER HEATING SYSTEM GENERAL INFORMATION 1 AI CEC-NRCC-PLB-01-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-PLB-01-E Water Heating System General Information (Page 1 of 2) Project Name: Next Level Fitness Tenant Improvement Date Prepared: 10/27/2014 A. GENERAL INFORMATION/SYSTEM INFORMATION For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, refer to the 2013 Nonresidential Manual Note: The Enforcement Agency may require all forms to be incorporated onto the building plans. 1. Water Heater System Name: A O Smith ELJF-6 2. Water Heater System Configuration: Non -Central 3. Water Heater System Type: 4 4. Building Type: 0.92 S. Total Number of Water Heaters in Systems: 4 6. Central DHW Distribution Type: n/a 7. Dwelling Unit DHW Distribution Type: All Pipes Ins B. WATER HEATER INFORMATION Each water heater type requires a separate form. For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, refer to the 2013 Nonresidential Manual Note: The Enforcement Agency may require all forms to be incorporated onto the building plans. 1. Water Heater Type: Small Storage Electric 2. Fuel Type Electric Res 3. Number of Identical Water Heaters: 4 4. Efficiency: 0.92 S. Required Minimum Efficiency: 0.92 6. Standby loss percent or Standby loss total: 0.000 7. Rated Input 5,120 8. Pilot Energy: ❑ 9. Water Heater Tank Storage Volume: 6 10. Exterior Insulation On Water Heater: 0 11. Volume of Supplemental Storage: 12. Internal Insulation on Supplemental Storage: 13. Exterior Insulation on Supplemental Storage: PLUMBING COMPLIANCE FORMS & WORKSHEETS (check box if worksheet is included) . For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, refer to the 2013 Nonresidential Manual Note: The Enforcement Agency may require all forms to be incorporated onto the building plans. YES NO Form/Worksheet # Title ® ❑ NRCC-PLB-01-E Certificate of Compliance, Declaration. Required on plans for all submittals. ❑ ❑ NRCI-PLB-01-E Certificate of Installation. Required on plans for,0ftabTrrittal . Certificate of Installation, required on central sy to i. i -I Fesi"ttiQUIN hotel/motel application. I B ❑ ❑ NRCI-PLB-02-E ❑ ❑ NRCI-PLB-03-E Certificate of Installation, required on single dw -Iling unitAsysl; wa�s�ira,I�ig�iiri;g. — residential, hotel/motel application. �9 ' P' j ��J V t ❑ ❑ NRCI-PLB-21-H Certificate of Installation, required on HERS verified ce t I 10N residential, hotel/motel application. ❑ ❑ NRCI-PLB-22-H Certificate of Installation required on HERS verifi�sl-IS�Ie dwellin uni stems in - F 1�' high-rise_ residential, hotel/motel application. Certificate of Installation, required on any solar. water heating ❑ ❑I NRCI-STH-01-E CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 A T. • • • ENVELOPE MANDATORY MEASURES: NONRESIDENTIAL ENV -MM Project Name Date Next Level Fitness Tenant Improvement 10/27/2014 DESCRIPTION Building Envelope Measures: §110.8(a): Installed insulating material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20 Chapter 4, Article 3. §110.8(c): All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. §110.8(f): The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-13 between framing members. §110.7(a): All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. Manufactured fenestration products and exterior doors shall have air infiltration rates not exceeding 0.3 cfm/ft.2 of §110.6(a): window area, 0.3 cfm/ft.z of door area for residential doors, 0.3 cfm/ft.Z of door area for nonresidential single doors (swingingand sliding), and '1.0 cfm/ft.2 for nonresidential double doors (swinging). §110.6(a): Fenestration U -factor shall be rated in accordance with NFRC 100, or the applicable default U -factor. §110.6(a) : Fenestration SHGC shall be rated in accordance with NFRC 200, or NFRC 100 for site -built fenestration, or the applicable default SHGC. §110.6(b): Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). CITY OF LA QUINT BUILDING &SAFETY DEP APPROVED ` FOR CONSTRUCTION DATE _____ BY Ene Pro 6.3 by EnefgySoft User Number: 6712 RunCode:-2014-10-27715:22:58 /D: Pae 19 of 37 1 1� 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Next Level Fitness Tenant Improvement Date 10/27/2014 System Name HVAC 1 Floor Area 1,315 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 2,513 Return Vented Lighting Return Air Ducts Return Fan Ventilation 219 Supply Fan Supply Air Ducts " TOTAL SYSTEM LOAD 1 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 57,000 35,593 4,383 453 16,983 Total Output Btuh 57,000 0 Output Btuh/s ft 43.3 1,780 849 Cooling System 0 0 Output perSystem 57,500 8,389 2,461 1 219 10,150 Total Output Btuh 57,500 1,191 6,844 -1,191 Total Output Tons 4.8 1,780 849 Total Output Btuh/s ft 43.7 Total Output s ft/Ton 274.4 48,732 27,640 Air System CFM perSystem 1,650 HVAC EQUIPMENT SELECTION Airflow cfm 1,650 Carrier50EZ060 42,447 10,086 35,601 Airflow cfm/s ft 1.25 Airflow cfm/Ton 344.3 Outside Air % 13.3% Total Adjusted System Output 42,447 10,086 35,601 (Adjusted for Peak Design conditions) - TIME OF SYSTEM PEAK Aug,4 PM Jan 1 AM Outside Air cfm/s ft 0.17 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 219 cfm 70 OF 64 OF 105 OF 106 OF fns Heating Coil Supply Fan 1,650 cfm 105 OF ROM 70 OF rn CITY nEI A Q1 IIISIJ:A-. COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of.Coolin Peak „" r,,r. 0 C. rr- 111/78°F Outside Air 219 cfm 75 / 64 OF 80/66°F 59/58°F 60/58°F ,.,` .PROVED CONSTRUCTION Cooling Coil Supply Fan DATE BY 61 / _59-F 1,650 cfm 58.6% ROOM 74 / 64 OF EnergyPro 6.3 by Energ Soft User Number: 6712 Run Code: 201410-27715:22:58 /D: Page 20 of 37 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Next Level Fitness Tenant Improvement 10/27/2014 System Name Floor Area HVAC 2 1,169 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,591 Return Vented Lighting Return Air Ducts Return Fan Ventilation 195 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 57,000 23,129 3,897 194 7,316 Total Output Btuh 57,000 0 Output Btuh/s ft 48.8 1,156 366 Cooling System 01 0 Output perSystem 57,500 7,038 2,228 195 9,080 Total Output Btuh 57,500 1,191 1,156 1 33,670 6,124 -1,191 Total Output Tons 4.8 366 Total Output Btuh/s ft 49.2 Total Output s ftfTon 244.0 15,936 Air System CFM perSystem 1,650 HVAC EQUIPMENT SELECTION Airflow cfm 1,650 Carrier 50EZ060 41,746 11,057 35,601 Airflow cfm/s ft 1.41 Airflow cfm/Ton 344.3 Outside Air % 11.8% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 41,746 11,057 Jul 5 PM 35,601 Outside Air cfm/s ft 0,17 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCH ROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 65 OF 105 OF 106 OF Outside Air 195 cfm Heating Coil Supply Fan 105 OF 1,650 cfm ROOM JE 70 OF 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures Time Cool in at of ,Peak , w lri r 'e U 109 / 77 OF 79 / 66 OF 59 / 58 OF 60 / 58 OF gU,t -� _; _; ,rETy DEPT. Outside Air r:-. c �.. :>T^nUCTION -4 195 cfm Cooling Coil Supply Fan 60 / 58 ° 1,650 cfm DATE —58-5-% — i VROOM 75/64°F 74/64°F EnergyPro 6.3 by Energ Soft User Number: 6712 Run Code: 201410-27715:22:58 ID: Page 21 of 37 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Next Level Fitness Tenant Improvement 10/27/2014 System Name Floor Area HVAC 3 1,458 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 2,096 Return Vented Lighting Return Air Ducts Return Fan Ventilation 243 Supply Fan Supply Air Ducts COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 57,000 30,036 4,860 356 13,359 Total Output Btuh 57,000 0 Output Btuh/s ft 39.1 1,502 668 Cooling System 0 0 Output per System 57,500 9,342 2,664 243 11,280 Total Output Btuh 57,500 1,191 1,502 -1,191 Total Output Tons 4.8 668 Total Output Btuh/s ft 39.4 TOTAL SYSTEM LOAD 1 43,573 7,524 Total Output s ft/Ton 304.3 24,784 Air System CFM per System 1,650 HVAC EQUIPMENT SELECTION Airflow cfm 1,650 Carrier 50EZ060 42,601 10,132 35,601 Airflow cfm/s ft 1.13 Airflow cfm/Ton 344.3 Outside Air % 14.7% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 42,601 10,132 Jul 4 PM 35,601 Jan 1 AM Outside Air cfm/s ft 0.17 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 63 OF 105 OF 106 OF Outside Air 243 cfm Heating Coil Supply Fan 1,650 cfm 105 OF ROOM 70 OF 70 OF I COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of CoolingFreak- 111 /78°F U1 I Y OF LA QUINTA 80/67°F 59/58°F 60/58°F BUILDING & SAFETY DEPT. �E H H Outside Air c Supply Fan rUH ti%ONSTRUCTdI 243 cfm Cooling Coil pp y ° 8 F 1,650 cfm Cq1 'rE 58.9 % R OM 75 / 64 OF 74/640 I Energ Pro 6.3 by Energ Soft User Number., 6712 Run Code: 201410-27T15:22:58 /D: Page 22 of 37 ZONE LOAD SUMMARY Project Name Next Level Fitness Tenant Improvement Date 10/27/2014 System Name HVAC 1 Floor Area 1,315 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM I Sensible Latent CFM Sensible Boot Camp 1.0 219 Aug 4 PM 2,513 44,218 8,506 453 27,246 M ii i h -z e-%' ♦ I o (,' --n T c<p�mi ° ,� It 9 U 9 TOTALS1 0 0 0 219 Aug 4 PM 1 44,218 8,506 1 27,246 (BLOCK LOAD) EnergyPro 6.3 by EpergySoft J s r Number: 6712 Run Code: 2014-10-27715:22:58 ID: Page 23 of 37 • ZONE LOAD SUMMARY Project Name Next Level Fitness Tenant Improvement Date 10/27/2014 System Name HVAC 2 Floor Area 1,169 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible Personal Training 1.0 195 Jul5 PM 1,591 30,303 7,577 194 16,439 C7 coo (A .en. J .0 --f I i TOTALS 0 0 0 195 Jul5 PM 1 30,303 7,577 16,439 Z V Z BLOCK LOAD) EnergyPro 6.3 by E erj ySoft 7p dj Number: 6712 Run Code: 201410-27T15:22:58 /D: Page 24 of 37 • ZONE LOAD SUMMARY Project Name Next Level Fitness Tenant Improvement Date 10/27/2014 System Name HVAC 3 Floor Area 1,458 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible F8 in 42 1.0 243 Jul 4 PM 2,096 39,599 9,431 356 24,737 ------------- A I(I ^ J I a C) � ~ -C, L— TOTALS 0 0 0 243 Jul4 PM 39,599 9,4311 24,737 (BLOCK LOAD) EnergyPro 6.3 by Ene"rgy'Soft 4 lir, umber. 6712 Run Code: 201410-27T15:22:58 ID: Page 25 of 37 • 0 • • 0 • ROOM LOAD SUMMARY Project Name Date Next Level Fitness Tenant Improvement 10/27/2014 System Name Floor Area HVAC 2 1,169 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name =Room Name Mult. I CFM I Sensible I Latent CFM I Sensible Latent CFM I Sensible Personal Training I Personal Training 1 1 1,5911 23,1291 3,897 1,5911 23,1291 3,897 1941 7,316 PAGE TOTAL TOTAL` 11591 23,129 3,897 194 7,316 1,591 23,129 3,897 194 7,316 Total includes ventilation load for zonal systems. EnergyPro 6.3 by EnerqySoft User Number: 6712 Run Code: 2014-10-27715:22:58 ID: Page 27 of 37 • ROOM HEATING PEAK_ LOADS Project NameDate Next Level Fitness Tenant Improvement 10/27/201,4 ROOM INFORMATION DESIGN CONDITIONS Room Name Boot Camp Floor Area 1,315.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value AT 'F Btu/hr R-30 Roof Attic 1,315.0 0.0310 X 44 = 1,794 R-19 Wall 797.0 0.0740 X 0.7100 X 44 c 2,595 Double Metal 288.0 44 = 8,997 44 = 3,597 = = Slab -On -Grade perim = 112.0 0.7300 X X X X X = = X X = = = X X = X X X = = = X = X = = = = = X X X X X = X = X X o = = = X X V Un X X another room 10.00 X Or66 Height - - APP )VED Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,315 X Area age o aty 16,98 E—BY _.11 TOTAL HOURLY HEAT LOSS FOR ROOM 16,983 EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 201410-27715:22:58 /D: Page 29 of 37 0 0 • ROOM HEATING PEAK LOADS Project Name71012712014 Next Level Fitness Tenant Improvement. ate ROOM INFORMATION DESIGN CONDITIONS Room Name Personal Training Floor Area 1,169.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X x X x x to Ceiling U -Value 0.0310 X 0.0740 X AT 'F Btu/hr 44 = 1,595 44 = 938 44 = 3,499 44 c 1,285 = = = = = = = = = = = = = R-30 Roof Attic 1,169.0 R-19 Wall 288.0 Double Metal 112.0 0.7100 X Slab -On -Grade perim = 40.0 0.7300 X X X X X X X X X X X X X X X = X = X X X = = = X = X X X = = = X = x x !Tv n i ni R rG x AP �HIOVED xAPR another room ���1TE 10.00 X 0000 Height ACH Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,169 X Area '`" i �� ION7,31s Fuge o / 60 -]—X �� B -_ --_0 TOTAL HOURLY HEAT LOSS FOR ROOM, 7,316 EnergyPro 6.3 by EnergySoft User Number: 6712 RunCode: 2014-10-27T15:22:58 ID: Page 30 of 37 • • ROOM HEATING PEAK LOADS Project Name Next Level Fitness Tenant Improvement , _ Date 10/27/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Fit in 42 Floor Area 1,458.0 ft2 Indoor Dry Bulb Temperature. 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area x x x x x x x x x x x x x x X x x x x x x x x x x x x x x x to Ceiling U -Value AT *F c = _ = = = = = = = = = = = = = = = = = = = = = = = AE :-)`/F m BY Btu/hr R-30 Roof Attic 1,458.0 0.0310 x 44 X 44 1,989 R-13 Wall 635.0 0.1020 2,850 R-19 Wall 388.0 0.0740 x 44 1,263 Double Metal 112.0 .0.7100 x 44 3,499 Slab -On -Grade perim = 117.0 0.7300 x 44 X 3,758 x x x X x x X x x x x x x x x x x x x X x��,�-, F x U'Lul TA DEPT. 1 x APS ( x FOR CONS Page Total DATE _________ i"6�O�X- -1 AT cTIo Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 x 1.064 Schedule Air Sensible Fraction through an interiors urface x 1,458 x Area another room 10.00 x Height ACI 13,359 _ TOTAL HOURLY HEAT LOSS FOR ROOM. 13,359 EnergyPro6.3 by EnergySoft . User Number: 6712 RunCode: 201410-27T15:22:58 /D: Page 31 of 37 • • • ROOM COOLING PEAK LOADS Project Name71012712014 ate Next Level Fitness Tenant Improvement ROOM INFORMATION DESIGN CONDITIONS Room Name Boot Camp Time of Peak Jul 5 PM Floor Area 1,315.0 ft' Outdoor Dry Bulb Temperature 109 OF Indoor Dry Bulb Temperature 74 OF Outdoor Wet Bulb Temperature 77 OF Conduction Area . U -Value DETD' Btu/hr R-30 Roof Attic 1,315.0 X 0.0310 X 48.5 = 1,976 R-19 Wall 50.0 X 0.0740 X 35.8 = 132 R-19 Wall 136.0 X 0.0740 X 36.2 = 365 Double Metal 64.0 X 0.7100 X 25.9 = 1,178 R-19 Wall 523.0 X 0.0740 X 47.2 = 1,828 Double Metal 224.0 X 0.7100 X 25.9 = 4,123 R-19 Wall 88.0 X 0.0740 X 51.3 = 334 X X X X Page Total 9,937 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Weighting Solar Gain Orientation Area SGF SC Factor Btu/hr Window (SE) 64.0 X 24 X 0.668 X 1.492 = 1,548 Window (SW) 112.0 X 83 X 0.668 X 0.580 = 3,610 Window (NW) 112.0 X 143 X 0.668 X 0.426 = 4,553 X X X X X X = X X X X X X = X X X X X X = Page Total 9.711 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr Li hts 1.00 X 1,315 X 0.867 Watts/Sgft X 3.413 Btu/Watt X 0.999 = 3,887 Occupants 1.00 X 1,315 X 250 Btu/OCC. / 60 Sgft/occ. X 1.000 = 5,479 Receptacle 1.00 X 1,315 X 1.500 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 6,732 Process 1.00 X 1,315 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 0 Process Lighting 1.00 X 1,315 X 0.000 Watts/Sgft X 3.4131 BtulWatt X 1 0.000 = 10 Infiltration:[ 1.00 X 1.064 X 1,315 X 10.00 X 0.0 Schedule Air Sensible Area Ceiling Height ICH 1-16Y Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 35,746 Sched. Latent Gain Frac. Area Heat Gain CONSTRUCTI to/hr Occupants 1.00 X 1,315 X 200 Btuh/OCC. / 60 SgfUOCc. = 4,383 Receptacle 1.00 X 1,315 X 0.000 Watts/Sqfl OF3.413 TE Btuf%o)t = 0 Process 1.00 X 1,315 X o.000 Watts/Sgft X 3.413 tutwoll = 0 Infiltration:[ 1.00 X 4,771 X 1,315 X 10.00 X 0.00 /60] X 0.00000 = 0 Schedule Air Sensible Area Ceiling Height ACH AW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,383 EnergyPro 6.3 by EnergySoft User Number: 6712 RunCode: 2014-10-27715:22:58 /D: Page 32 of 37 F- ,, Co • • ROOM COOLING PEAK LOADS Project Name71012712014 ate Next Level Fitness Tenant Improvement ROOM INFORMATION DESIGN CONDITIONS Room Name Personal Training Time of Peak Jul 5 PM Floor Area 1,169.0 ft' Outdoor Dry Bulb Temperature 109 OF Indoor Dry Bulb Temperature 74 OF Outdoor Wet Bulb Temperature 77 OF Conduction Area U -Value DETD' Btu/hr R-30 Roof Attic 1,169.0 X 0.0310 X 48.5 = 1,757 R-19 Wall 200.0 X 0.0740 X 36.2 = 536 R-19 Wall 88.0 X 0.0740 X 51.3 = 334 Double Metal 112.0 X 0.7100 X 25.9 = 2,062 X X = X X = X X = X X = X X I= Page Total 4,689 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Weighting Solar Gain Orientation Area SGF SC Factor Btu/hr Window (NM 112.0 X 143 X 0.668 X 0.426 = 4,553 X X X = X X X = X X X = X X X = X X X = X X X = X X X = X X X = Page Total 4,553 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr Lights 1.00 X 1,169 X 0.760 Watts/Sgft X 3.413 Btu/Watt X 0.999 = 3,031 Occupants 1.00 X 1,169 X 250 Btu/OCC. / 60 Sgft/occ. X 1.000 = 4,871 Receptacle 1.00 X 1,169 X 1.500 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 5,985 Process 1.00 X 1,169 X 0.000 Watts/Sgft X .3.413 Btu/Watt X 1.000 = 0 Process Lighting 1.00 X 1,169 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 0.000 = 0 Infiltration:[ 1.00 X 1.064 X 1,169 X 10.00 X 0.00 /60 X 38 = 0 Schedule Air Sensible Area Ceiling Height AC Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM O. Sched. OU'LOING Latent Gain Frac. & SAFETY �pT Area Heat Gain ,ry Occupants 1.00 X 1,169 X 200 Btuh/occ. / d6p PP v 3,897 _ Receptacle 1.00 X 1,169 X 0.000 Watts/Sgft 3.413 CCC BJJJtju/Warttt UQ� N 0 Process 1.00 X 1,169 X 0.000 Watts/Sgft X _ 3.413 Btu/Watt = 0 'tom—BY Infiltration:[ 1.00 X 4,771 X 1,169 X 10.00 X0.00 /60] X Schedule Air Sensible Area Ceiling Height ACH AW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,897 EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 2014-10-27715:22:58 /D: Page 33 of 37 t r 10 C • ROOM COOLING PEAK LOADS Project Name Date Next Level Fitness Tenant Improvement 10/27/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Fit in 42 Time of Peak Jul 5 PM Floor Area 1,458.Oft' Outdoor Dry Bulb Temperature 109 OF Indoor Dry Bulb Temperature 74 OF Outdoor Wet Bulb Temperature 77 OF Conduction Area U -Value DETD' Btu/hr R-30 Roof Attic 1,458.0 X 0.0310 X 48.5 = 2,191 R-13 Wall 635.0 X 0.1020 X 35.1 = 2,270 R-19 Wall 250.0 X 0.0740 X 36.2 = 670 R-19 Wall 138.0 X 0.0740 X 51.3 = 524 Double Metal 112.0 X 0.7100 X 25.9 = 2,062 X X = X X = X X = X X = Page Total 7,717 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Weighting Solar Gain Orientation Area SGF SC Factor Btu/hr Window (NIA 112.0 X 143 X 0.668 X 0.426 = 4,553 X X X = X X X = X X X = X X X = X X X = X X X = X X X = X X X I= Page Total 4,553 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr Li hts 1.00 X 1,458 X 0.918 Watts/Sgft X 3.413 Btu/Watt X 0.999 = 4,562 Occupants 1.00 X 1,458 X 250 Btu/occ. / 60 Sgft/occ. X 1.000 = 6,075 Receptacle 1.00 X 1,458 X 1.500 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 7,464 Process 1.00 X 1,458 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 0 Process Lighting 1.00 X 1,458 X 1 0.000 Watts/Sgft X 1 3.413 Btu/Watt X 0.0001 = 1 0 Infiltration:[ 1.00 X 1.064 X 1,458 X 10.00 X 0.00 / 60 J X 38 = 0 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM I I Y UF LA QUINU7 Sched. Latent Gain Frac. Area Heat Gain BUILDING & SAFETY QtU�r�• Occupants 1.00 X 1,458 X 200 Btuh/occ. Receptacle 1.00 X 1,458 X 0.000 Watts/Sgft / 60: Pr�lSg1k//pGC v X 3F C3tUWsi8UO 4,860 ION o Process 1.00 X 1,458 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 BY Infiltration: 1.00 X 4, 771 X - E -X - X 1,458 X 10.00 000• /6t)']X-OO.LdO� - 0 Schedule Air Sensible Area Ceiling Height ACH pyo/ Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,860 EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 201410-27715:22:58 /D: Page 34 of 37 • • • ROOM COOLING COIL LOADS Project Name Date Next Level Fitness Tenant Improvement 10/27/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Boot Camp Time of Peak Aug 4 PM Floor Area 1,315.0 ft' Outdoor Dry Bulb Temperature 111 OF Indoor Dry Bulb Temperature 74 OF Outdoor Wet Bulb Temperature 78 OF Conduction Area U -Value DETD' Btu/hr R-30 Roof Attic 1,315.0 X 0.0310 X 53.4 = 2,176 R-19 Wall 50.0 X 0.0740 X 36.9 = 137 R-19 Wall 136.0 X 0.0740 X 38.4 = 386 Double Metal 64.0 X 0.7100 X 26.9 = 1,221 R-19 Wall 523.0 X 0.0740 X 54.4 = 2,104 Double Metal 224.0 X 0.7100 X 26.9 = 4,275 R-19 Wall 88.0 X 0.0740 X 49.7 = 324 X X X X Page Total 10,622 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Weighting Solar Gain Orientation Area SGF SC Factor Btu/hr Wndow (SE) 64.01 X 29 X 0.668 X 1.398 = 1,716 Window (S K0 112.0 X 120 X 0.668 X 0.454 = 4,074 Window (NK9 112.0 X 86 X 0.668 X 0.478 = 3,082 X X X X X X X X X X X X X X X X X X Page Total 8,873 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr Lights 1.00 X 1,315 X 0.867 Watts/Sgft X 3.413 Btu/Watt X 0.999 = 3,887 Occupants 1.00 X 1,315 X 250 Btu/OCC. / 60 Sgft/OCC. X 1.000 = 5,479 Receptacle 1.00 X 1,315 X 1.500 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 6,732 Process 1.00 X 1,315 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 0 Process Lighting 1.00 X 1,315 X 1 0.000 Watts/Sgft X 1 3.413 Btu/Watt X 0.0001 0 Infiltration:[ 1.00 X 1.064 X 1;315 X 10.00 X 0.00 / 60 ] X 38 = 0 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Sched. Latent Gain Frac. V �V IA V fl' 1- Q � I ^'-73' Area Heat Gain UNG & SAF Occupants 1.00 X 1,315 X 200 Btuh/occ. Receptacle 1.00 X 1,315 X 0.000 Watts/S ft 4 / ,6.0 �S o , . _ X �3 B ��yj t 3 3 0 Process 1.00 X 1,315 X 0.000 Watts/Sgft C(B�(uatf� X i3 Btu/WItt'UG ION 0 Infiltration:[ 1.00 X 4,771 X 1,315 X 10.00 X 0.T/F60]- S 000 = 0 Schedule Air Sensible Area Ceiling Height AC Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,383' Lcneryyrru u.a uy cnergyoun user wumoer: 0172 nuncooe: zu747u-z7T75:zz:58 /D: Page 35 of 37 1 • ROOM COOLING COIL LOADS Project Name Date Next Level Fitness Tenant Improvement 10/27/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Personal Training Time of Peak Jul 5 PM Floor Area 1,169.0 ft' Outdoor Dry Bulb Temperature 109 OF Indoor Dry Bulb Temperature 74 OF Outdoor Wet Bulb Temperature 77 OF Conduction Area U -Value DETD' Btu/hr R-30 Roof Attic 1,169.0 X 0.0310 X 48.5 = 1,757 R-19 Wall 200.0 X 0.0740 X 36.2 = 536 R-19 Wall 88.0 X 0.0740 X 51.3 = 334 Double Metal 112.0 X 0.7100 X 25.9 = 2,062 X X = X X = X X = X X = X X = Page Total 4,689 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Weighting Solar Gain Orientation Area SGF SC Factor Btu/hr Window (NM 112.0 X 143 X 0.668 X 0.426 = 4,553 X X X = X X X = X X X = X X X = X X X = X X X = X X X = X X X = Page Total 4,553 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr Li hts 1.00 X 1,169 X 0.760 Watts/Sgft X 3.413 Btu/Watt X 0.999 = 3,031 Occupants 1.00 X 1,169 X 250 Btu/occ. / 60 Sgft/occ. X 1.000 = 4,871 Receptacle 1.00 X 1,169 X 1.500 Watts/Sgft X 3.413 Btu[Watt X 1.000 = 5,985 Process 1.00 X 1,169 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 0 Process Liqhtinq X 1,169 X 0,0001 Watts/Sgft X 3.413 Btu/Watt X 1 0.0001 = 0 Infiltration:[ 1.00 X 1.064 X 1,169 X 10.00 XE 000 6U- �I X _ Schedule Air Sensible Area Ceiling Height AC I r NTA Fraction t TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 79 Sched.O\ /E^ Latent Gain Frac. Area Heat Gain F V CONSTRUCT L� to/hr Occupants 1.00 X 1,169 X 200 Btuh/ocC. / 60 SgfUocc. = 3,897 Receptacle 1.00 X 1,169 X 0.000 Watts/Sgft XJ .413 BttuuN�ll�atttt = 0 Process 1.00 X 1,169 X 0.000 Watts/Sgft 3� —Btu7VUatt--=— 0 Infiltration:[ 1.00 X 4,771 X 1,169 X 10.00 X 0.00 /60] X 0.00000 = 0 Schedule Air Sensible Area Ceiling Height ACH AW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,897 tnergyrro o.i Dy tnergyson user Number: 6712 RunCode: 201410-27715:22:58 /D: Page 36 of 37 1 • • • ROOM COOLING COIL LOADS Project Name Date Next Level Fitness Tenant Improvement 10/27/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Fit in 42 Time of Peak Jul 4 PM Floor Area 1,458.0 ft' Outdoor Dry Bulb Temperature 111 OF Indoor Dry Bulb Temperature 74 OF Outdoor Wet Bulb Temperature 78 OF Conduction Area U -Value DETD' Btu/hr R-30 Roof Attic 1,458.0 X 0.0310 X 57.6 = 2,603 R-13 Wall 635.0 X 0.1020 X 37.4 = 2,424 R-19 Wall 250.0 X 0.0740 X 38.0 = 702 R-19 Wall 138.0 X 0.0740 X 52.2 = 533 Double Metal 112.0 X 0.7100 X 26.9 = 2,137 X X X X X X X X Page Total 8,400 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Weighting Solar Gain Orientation Area SGF SC Factor Btu/hr Window (NtM 112.0 X 97X 0.668 X 0.485 = 3,535 X X X X X X = X X X = X X X X X X X X X = X X X X X X Page Total 3,535 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr Li hts 1.00 X 1,458 X 0.918 Watts/Sgft X 3.413 Btu/Watt X 0.999 = 4,562 Occupants 1.00 X 1,458 X 250 Btu/OCC. / 60 Sqft/occ. X 1.000 = 6,075 Receptacle 1.00 X 1,458 X 1.500 Watts/Sgft X 3.413 Btu[Watt X 1.000 = 7,464 Process 1.00 X 1,458 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 0 Process Li htin 1.00 X 1,458 X 0.0001 Watts/Sgft X 3.413 Btu/Watt X 0.0001 0 Infiltration:[ 1.00 X 1.064 X 1,458 X 10.00 X 0.00 / 60 ] X 38 = 0 Schedule Air Sensible Area Ceiling Height AC FractionI TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM ' ,,, , - Sched. � a ,0 r- Latent Gain Frac. Area Heat Gain P R��n®UE to/hr Occupants 1.00 X 1,458 X 200 Btuh/occ. / 60 t CVrV:7FF�U�i 4,860 Receptacle 1.00 X 1,458 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 Process 1.00 X 1,458 X 0.000 Watts/Sgft 3.413 Btu1W tt = �t 0 Infiltration:[ 1.00 X 4,771 X 1,458 X 10.00 X 0.00 /60] X 0.00000 = 0 Schedule Air Sensible Area Ceiling Height ACH AW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,860 EnergyPro 6.3 by EnergySoft User Number: 6712 RunCode: 201410-27715:22:58 /D: Pace 37 of 37