05-5359 (RC)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
Property Address:
APN:
Application description:
Property Zoning:
Application valuation:
Applicant:
I hereby affirm under penalty of
Section 7000) of Division 3 of 1
License Class: B
C�0 5-0T0 0 0 53_59
46520"WASHINGTON ST STE '1
643-020-999-3 -30903
REMODEL - COMMERCIAL
REGIONAL COMMERCIAL
75000
Architect or
4
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner:
WASHINGTON 111 LTD
C/O JACK TARR
30240 RANCHO VIEJO RD. STE. B
SAN JUAN CAPISTRANO, CA 92675
Contractor:
RIVERO BUILDERS INC
84662 IDROVIA,COURT
PALM DESERT, CA 92211
(760)200-8822
Lic. No.: 862848
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 12/05/06
CONTRACTOR'S D RATION WORKER'S COMPENSATION DECLARATION -
under provisions o hapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations:
essionals and my cense is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
License 8 2848 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
_ I have and will maintain workers' compensation insurance, as required by Sectiori 3700 of the Labor
Code, for the performance of the work.for which this permit is issued. My workers' compensation
-----DWNER-BUILDER DECLARATION insurance carrier and policy numbe -are:�_�
hereby affirm under penalty of per ry t at I am exempt from the Contractor's State License Law for the Carrier EXEMPT olicy Number Z PT
following reason (Sec. 7031 .5, Busi and Professions Code: Any city or county that requires a permit to _ I certify that, in the perfo mafi �lework for which this p it is issued, I shall not employ any
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the - person in any manne .so asubjecttotheworkers' mpensation laws of California;
permit to file a signed statement that. he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I s'�+'d-ct to the workers' compe ation provisions of Section
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the„Labor Cie, Iith co y withthose proions.
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001.:
1 _) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within '
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.). _
1 _) I am exempt under Sec. B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address: .
LQPER711IT
WARNING: FAILURE TO SE URE WORKER ' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO W.IMINAL PE ALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDI TOT E COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE,--MTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for -act or omission related to the work being
performed under or following issuancJ
rit2. Any permit issued as a result of this aecomes null and void if w is not commenced
within 180 days from date of issuanermit„or cessation of work for 80 days will subject
permit to cancellation.
I certify that I have read this application and state /formation is correct. I agree comply with all
city and c my ordinances and ate laws relatingshereby authoriz representatives
of thi ounty to enter upo eabove-mentioned r insp tion purpose
gnature (Applicant or Agen
vj ,
,Application Number . . 05-00005359
------Structure Information 1360 SF TI @ SUITE 1. -----
Other struct info . . . . . CODE EDITION 2001/2005
C FIRE SPRINKLERS YES
MIXED-USE OCCUPANCY NO
OCCUPANT LOAD 63.00
1ST FLOOR SQUARE FOOTAGE 1360.00
Permit BUILDING PERMIT
Additional desc .
Permit Fee 527.00 Plan Check Fee 342.55
Issue Date Valuation . . 75000
Expiration Date X6/03/07
Qty Unit, Charge` Per Extension
jl. r BASE FEE 414.50
25.00 4.5000, THOU ',,BLDG 50,001-100,000 112.50 '
,'Permit .ELECT - ADD/ALT/REMa ,
Additional desc ..
Permit Fee. 74.10 -Plan Check Fee 18..53
Issue Date Valuation 0
Expiration Date '6/03/07
" Qty Unit Charge Per ` Extension
>_ BASE FEE
2 - 15.00
0.00 .7500 PER: ELEC DEVICE/FIXTURE 1ST 20 15.00
98.00, 4500 EA. ELEC DEVICE/FIXTURE >20 44.10
c
Permit. MECHANICAL
.Additional desc
Permit Fee. . . 37:00 Plan Check Fee 9.25
Issue Date . . Valuation 0
Expiration Date'6/03/07
Qty Unit Charge Per Extension
BASE -FEE 15.00
2.00 4.5000 EA MECH VENT INST/ DUCT ALT 9.00
2.00 6.500-0 EA MECH VENT FAN 13.00
---------------------------------------------------------------------------- ,
Permit PLUMBING
Additional desc
Permit Fee . . . 82.50 Plan Check Fee 20.63
Issue Date Valuation 0
LQPERAIIT
LQPERAIIT
Application Number . . . 05-00005359
Permit . . . . . PLUMBING
Expiration Date 6/03/07
Qty Unit Charge Per
Extension
BASE FEE
15.00
7.00 6.0000 EA PLB FIXTURE
42.00
1.00 15.0000 EA PLB BUILDING SEWER
15.00 -
1.00 7.5000 EA PLB WATER HEATER/VENT
7.50
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
Special Notes and Comments
11360 SF COFFEE SHOP T.I. SUITE'1
OCCUPANCY A-3, TYPE V -N, "JUST JAVA",
OCC. LOAD 63, 2001 CBC, CMC, CPC, 2004,;
CEC, 2005 CAL. ENERGY CODE
-
----------------------------------------------------------------------------
Other Fees . . ACCESSIBILITY PLAN
REVIEW
34.26
ENERGY REVIEW FEE
_
34.26
HOURLY PLAN CHECK.
150.00
STRONG MOTION (SMI),
- COM
15.75
Fee summary Charged Paid Credited
Due
Permit Fee Total •720.60 .00
.00
720.60
Plan'Check Total 390..96 .00
.00
390.96
Other Fee Total 234.27 00
.00
234.27
- Grand Total 1345.83 00
.00
1345.83
LQPERAIIT
CITY OF LA QUINTA SURA CONTRACTOR LIST
BUILDER ��`
JOB ADDRESS ZDV PERMIT NUMBER t OWNER BUILDER—/
This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list .or their. employees are authorized to work
on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance
of building permit. For each applicable trade, all information requested below must be completed by applicant. °On File" is not an acceptable response.
..
Trade./..Class�fica;ion
:. .:....:?`:::::;
::: ::.:.: :::;'
Contractor.._.......__::.._.._ _. _..
.....:....:.::.. .
. `::::.:.:,..
::.::::>.::::.;.::; :::;:::: :...::
_.__:_::_:...::. 8tate:.�ontractots.Licetus.. ::.
::..: :Wor kers Com ensation :l�su�anee'Cit .. Business Uc
"ens#'
Company Name
Classification
(e.g. A. B, C-8)
License Number
(zxxxxx)
Exp. Date
(xx/xxlxx)
Carrier Name
(e.g. State Fund, CalComp)
Policy Number
(Format Varies)
Exp. Date License Number
(xx/xx/xx) (xxxx)
Exp. Date
(xx/xx/xx)
EARTHWORK (C-12)
CONCRETE (C-8)'::-'C�
��
�!�
l O ► �/
3 78
FRAMING .IC -5) `.' :.
�yJ
-� �
22/
3
F41
./6/316
STRUCT.'STEEL 1C-51) '
MASONRY (C-29)
PLUMBING (C-36)
, " ,7
-
l� 7
7i
'�
31�
EATN; PLASTER (C=35)
DRYWALL IC -9).
Q -'OSI
ELECTRICAL. (C-10)
Y 1 n,
RQOFING
:SHEET METAL (C-431
s
GLAZING (C-,1.7)::::..:....
►
INSULATION (G-2)
SEWAGE DISP4:(Q-42)-
(C-42)
PAINTING
PAINTING
CERAMIC TILE (C-54)
CABINETS (C-6)
FENCING (C-13)'
LANDSCAPING (C=27.).
POOL (C-531
Permit # �. Cj
i
Project Address:
A. P. Number:
Contractor:
Address:
City, ST, Zip:
Telephone:
State Lie. #
�°), Engr., Designer;
Address: 1 32
..A City of La Quints
Building Ek Safety Division
P.O. Box 1'504,'78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
' IBuilding Permit Application and Tracking Sheet
Owner's Name:
Address:
City, ST, Zip:
City, ST, Zip
Telephone: TZ
State Lie. #:
Name of Contact Person:
Telephone # of Contact Person;
# Submittal
Plan Sets
Structural Calcs.
Truss Coles.
Energy Cala.
Flood plain plan
Grading. plirt
Subcoutactor List .
Grant Deed
H.O.A. Approval
IN HOUSE:-
Planning Approval
Pub. Wks. Appr
School Fees
Project Description:
Lie. #:
Construction Type:
vOcenp ncy:
PrqJect type (circle one): New Add'n Alter Repair Demo
Sq. Ft.:
#Stories:
Estimated Value of Project:
APPLICANT:
DO NOT WRITE BELOW THIS UNE
Reed
IRACIMG
PERMIT FEES
Plan Check submitted
�'
Item
Amount
Reviewed, rnidy r orrections
0 a Check Deposit
Called Contact Person
lan Check Balance
Plans Picked. up
Construction
Plans resubmitted
.
Mechanical
2" Review, ready for correctio
sue
Electrical
Called Contact Person
Plumbing
Plans picked up
/
S.M.L
Plans resubmitted
Grading
Review, ready for.corrections/issue
Developer Impact Fee
Called Contact Person
A.I.P.P.
.Date of permit issue
Total
COACHELLA VALLEY WATER DISTRICT ASSESSOR'S PARCEL NUMBER
85-995 Avenue 52
Coachella, California 92236
,(760) 398-2651
APPLICATION FOR WASTEWATER INTERCEPTOR/SEPARATOR'APPROVAL
APPLICANT: Submit this form with a copy of a SCALED plot plan (1" = 20'to 1" = 40' SCALE) drawn to District specifications. A nonrefundable filing fee is required
when the application is submitted. Check must be made payable to the Coachella Valley Water District Approval of this application shall remain valid for a period
not to exceed one (1) year from date of payment
Plan Check No.
A ent,.Contrac or, Contact P a
Addresscity State . Zip elephone
j
.OZJ \
Owner
Address- City State Zip Telephone
FV. cyo
Job ProAd City Zip
2�3
Legal Description
DBA,r
PLEASE COMPLETE THIS SECTION FOR REVIEW OF FOOD ESTABLISHMENTS
NOTE: PLANS WILL NOT BE ACCEPTED UNLESS THIS APPLICATION IS COMPLETE AND THE PLAN CHECK FEE IS PAID.
GENERAL CONSTRUCTION: ,
Type of Construction:
New Food Facility Remodel of Existing Food Establishment Hours of Operation Seating Capacity: Internal External
External Seating with Misters or Heaters Baan with Food Service Bar Nonfood Service Water Softener
Service:
Multiservice (reusable) Single Service (disposable)
OWNER/REPRESENTATIVE DECLARATION: I certify that I have'read the entire application and state that all information is correct I understand that the amount of fee
paid is based on my declaration of information on this form and.that incorrect information is grounds for. denial of the submitted plans. I also understand that plans will be
discarded if not picked up within sixty (60) days of approval or denial and that no inspection of my establishment will be conducted, or approval granted to operate, until all
proper infonna 'on req ei ed and plans have bew approved and retumed.
�J
Signatureh�l
No. of Systems
Type of Systems)
No. Dwelling Units
❑ Sand/Oil Grease Interceptor Waived
Fixture Units
❑ Grease Interceptor
❑ New ❑ Existing
❑ Lint Trap
❑ Replacement ❑ Addition
❑ Clarifier
❑ Connect to Sewer
Gal
i
REMARKS:
' %.
.O E,G$G
This application is:
Od_
Approved ❑ Denied ❑ Conditional Approval*
Fee $
Check No. /095
'See.Remarks
Date
Initial
Signa Ale
Date/ V
CV WD -921
RIVCO-DEPT.ENV..HEALTH Fax:760-320-1470 Aug 28 2007 17:31 P.02
COUNTY OF RIVERSIDE COMMUNITY HEALTH AGENCY
DEPARTMENT OF ENVIRONMENTAL HEALTH,
ENVIRONMENTAL HEALTH SERVICES
SUPPLEMENTAL: REPORT TO, SAN. FORM # DATE
SUBJECT., JVQi + 3olVa— PERMIT NO.
ADDRESS
I
�
NSPECTOR � Ve' `� � �t7
.REMARKS: .... _
Vhf -7Y1 .
o @ t<Li
w
ry---rf .
Lym 10
!:&A�s. :�fy&C6:� tS a-
SZs;vc� Cbl.l��� oc2#.A
t
a
ANA 18 (Rev e102) Distribution: WHITE—Office; CANARY—Owner:PINK=Office
Area.# IV COUNTY OF RIVERSIDE COMMUNITY HEALTH AGENCY
DEPARTMENT OF ENVIRONMENTAL HEALTH
PLAN CORRECTION
Plan Check # IVN05-098 Date 12/29/05
DBA "Just Java" Coffee Address 46-580 Washington St., La Quinta
Plans Submitted by Michael Hurst Phone 760-774-0271
Owner Dan Springle Address Phone
The plans are now approved subject to the conditions listed below and the attached compliance sheet.
1. This plan does not include sewage or water service approval. Prior to the final inspection provide a grease
interceptor sizing form or waiver from your local water agency. For more information call County of Riverside
Land Use at (760)863-7000.
2. All floor, wall and ceiling finishes in food service areas must be smooth and easily cleanable including
waitress and self service stations such as drink dispensers.
3. The mop sink must be of the floor basin style. Behind all sinks in the splash zone the finish must be water
proof to-a height of 8' (e.g. FRP/tile)
4. The trash enclosure must meet current standards and be finished so that the interior floor and walls are
smooth and easily cleanable. Seal these interior surfaces with an approved epoxy sealant.
5. All exterior and restroom doors must be self closing. Exterior doors must also be sealed against entry by
vermin. Service windows such as drive through windows must likewise be self closing and if greater than 216
square inches have dedicated air curtains. The delivery door air curtain must deliver air at a velocity of 1600
fpm at a height of 3' above the floor. See redline correction on page FS1.0
6. A construction guide has been issued with this plan correction. All issues not otherwise addressed by this
plan correction must be resolved according to the guidelines set forth therein.
7. The number of lockers provided shall be equal, or greater than the number of workers assigned to a peak
shift
8. Provide an approved commercial grade hot water heater with a minimum BTU rating of 65,000 or 15KW.
9. Sneeze guard requirement will be evaluated on-site at time of inspection.
10. Install approved cove base in the employee restrooms, I.e. ceramic tile with 3/8" radius and minimum 4" tall.
CONSTRUCTION INSPECTIONS: Contact the Plan Checker for a Preliminary Inspection when construction is approximately
80% complete, with plumbing, rough ventilation, and rough equipment installed. Request for inspection should be made at least five (5)
working days in advance. A compliance guide is attached to this plan correction sheet. All construction not otherwise addressed on the
plan correction must be performed in accordance with the guidelines set forth therein. A FINAL INSPECTION MUST be made upon
completion of ALL work including finished details. APPROVAL to operate shall not be granted, or remodeled areas approved to
operate, until the facility has passed the FINAL INSPECTION, and "APPLICATION TO OPERATE" has been completed and
PERMIT PEES have been paid.
Request for inspection should be made at least five (5) working days in advance.
PLANS CHECKED BY Jerry Dubin Phone (760) 320-1048
1 acknowledge the corrections noted herein and as indicated on the plans and agree to incorporate
them during construction:
Signature 10AD
Company����—zlv
Date
D�
,AN 3 0 2006
BY
COUNTY OF RIVERSIDE COMMUNITY HEALTH AGENCY
DEPARTMENT OF ENVIRONMENTAL HEALTH
APPLICATION FOR REVIEW OF FOOD ESTABLISHMENT CONSTRUCTION/REMODEL PLANS
+' 2 2 U':_ 0
NOTE: PLANS WILL NOT BE ACCEPTED UNLESS THIS APPLICATION .
IS COMPLETE, AND THE PLAN CHECK FEE IS PAID..
FOR OFFICIAL UW`
OFFICE
DATE TTS H
FEE•:_ •, ;•.r � i t• �
i'!••� � ' .
ESTABLISHMENT NAME: VV CT k,
JOB SITE ADDRESS: At,- �� t�u.>�5 1 `IJ �(.2t� ��, • �f ��-t 11 I�j C�J� N F40929 � Slf—A
(P
CITY:
CONTACT PERSON: PHONE -b FAX:
CONTACT'S ADDRESS
CITY;. Vlk )'-31_10K ZIP9,2Z_.tI
OWNER/OPERATOR NAME 9� (�} �L�S, PHONE:
ADDRESS CITY: ZIP:
CONTRACTOR/ARCHITECT NAME VU -h1Z PHO�rEf �I '1'1� • �'L'� FA v_.
ADDRESS �O rj p�j CITY:
�ZIP:22 -z-)-
A. GENERAL CONSTRUCTION:
Type of construction New Feed-Gae+Iity X Remodel of Existing Food Establishment
.Total square fo tage)(mc -ding all fta�ti, •-areas)� Z_ Hours of Operation
Seating Capacity for dining umber of workers per shift (incl. mgmt.)
B. SERVICE (Indicate ALL methods of food service to the public):
MENU: A menu of food and beverages sold at this facility is required to be submitted before your plans can be ehc&ed.
On-site preparation (cutting, cooking, assembly, etc.): yes nQ� Soup or salad bar: yes noY_
Food and beverages are individually packaged by manufacturer: yes no
Customer Self -Service Dispensers: yes no Full Service Bar: 'yes .:no
Type of customer utensils (cups, plates, forks, etc.) Multi -service (re -usable) or Single Service (disposable)
C. UTILITIES (Will Serve Letters):
NOTE: Before approved plans are released, the applicant shall provide to this Department Will Serve Letters which state" the
establishment is or will be connected to the utility.
Water Service: Public Water System NAME OF WATER COMPANY: CV V%) 0
Private Well (Must be potable)
Sewage Disposal: Public Sewer System NAME OF SEWER COMPANY: G,V W
Septic System (must be Environmental Health Land Use approved).
Grease Interceptor: Provide from Sewer District a Grease Interceptor size requirement letter or waiver letter.
OWNER/REPRESENTATIVE DECLARATION: I certify that I have read the entire application and state that all information is 66trect. I under-
stand that the amount of fee paid is based on my declaration of information on this form, and that incorrect information is grounds for denial of the -
submitted plans. I also understand that plans will be discarded if not picked up within sixty (60) days of approval or denial, and that no inspection
of my establishment will be conducted, or approval granted to operate, until all proper information requested has been received and plans have been
approved and returned. I have reviewed the Plan Construction Guide and my plans follow the guide.
Signature
DEH -SAN -002 (Rev 10/01)
Date
Distribution: WHITE—Office; YELLOW 'Customer
7 �al - --! �
G
.►
._ T
Certificate of 0ccupancOY
��
INm � nTmLL
oF.9 Building & Safety Department
}
This Certificate is issued pursuant to the requirements of Section 109 of the California Building
Code, certifying that, at the time of issuance, this structure was in compliance with the
provisions of the Building. Code and the various ordinances of the City regulating building
E
construction and/or use.
a
BUILDING ADDRESS: 46-520 WASHINGTON ST STE 1
�
.
Use classification: COMMERICAL ("JUST JAVA COFFEE") Building Permit No.: 05-5359
y i
= ;F
' Occupancy Group: A-3 Type of Construction: VN Land Use Zone: CR
A
s'
Owner of Building: WASHINGTON 111 LTD Address: 30-240 RANCHO VIEJO RD. STE B
;>
City, ST, ZIP: SAN JUAN CAPISTRANO, CA
By: STEVE TRAXEL
�d Date: 08-29-2007
Building Official
POST IN A CONSPICUOUS PLACE
A
TITLE 24 REPORT
Title 24 Report for:
Just Java Coffee Shop TI
46-580 Washington St. Suite A-6
La Quinta, CA 92253"
s
Project Designer:
Michael Hurst Architect
78080 Calle Estado Suite 203
La Qu'inta, CA 92253 .
760-774-0271
Report Prepared By:
.Gina Rose
Eagle Quest Specialties; Inc.
42335 Washington Suite F #330
Palm Desert, CA 92211
- (760) 345-4859
OMW n*
V/I uZuub
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.2 by EnergySoft Job Number: User Number: 5862
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Nonresidential Performance Title 24 Forms 3
Form ENV -MM Envelope Mandatory Measures .16
Form LTG -MM Lighting Mandatory Measures 17
Form MECH-MM Mechanical Mandatory Measures 18
HVAC System Heating and Cooling'Loads. Summary 20
Room Load Summary - 21
i
i
r
EnergyPro 4.2 by EnergySoft Job Number: User Number: 5862
e
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 Of 3 PERF -1
PROJECT NAME
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
DATE
Just Java Coffee Shop TI
DATE OF PLANS
9/12/2006
PROJECT ADDRESS
1, 360 sq.Ft.
mm
46-580 Washington St. Suite A-6 La Quinta
BUILDING TYPE
NONRESIDENTIAL HIGH RISE RESIDENTIAL
B Permit #
PRINCIPAL DESIGNER - ENVELOPE
TELEPHONE
Building
Michael Hurst Architect
760-774-0271
contractor performing this work.
DOCUMENTATION AUTHOR
TELEPHONE
Checked by/Date
Eagle Quest Specialties, Inc.
(760) 345-4859
Enforcement Agency Use
GENERAL INFORMATION
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations. This certificate applies only to a Building using the performance compliance approach.
The documentation preparer hereby certifies that the documentation is accurate and complete.
DATE OF PLANS
PATE
BUILDING CONDITIONED FLOOR AREA
1, 360 sq.Ft.
The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is
CLIMATE ZONE
15
BUILDING TYPE
NONRESIDENTIAL HIGH RISE RESIDENTIAL
HOTEUMOTEL GUEST ROOM
PHASE OF CONSTRUCTION
NEW CONSTRUCTION ADDITION
California as a civil engineer, mechanical engineer, or I am a licensed architect.
EXISTING + ADDITION/ALTERATION
STATEMENT OF COMPLIANCE
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations. This certificate applies only to a Building using the performance compliance approach.
The documentation preparer hereby certifies that the documentation is accurate and complete.
DOCUMENTATION AUTHOR ]SIG!:T�
PATE
Gina Rose
The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is
consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this
permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116,
through 118, and 140, 142, 143 or 149 of Title 24, Part 6.
ENV. LTG. MECH.
❑ ❑ ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to
sign this document as the person responsible for its preparation; and that I am licensed in the State of
California as a civil engineer, mechanical engineer, or I am a licensed architect.
❑ ❑ ❑ 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section
5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed
contractor performing this work.
❑ ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document
because it pertains to a structure or type of work described as exempt pursuant to Business and Professions
Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in
full in the Nonresidential Manual.)
ENVELOPE COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
ENV -1
Required Forms
PRINCIPAL ENVELOPE DESIGNER - NAME
SIGNATURE
LIC. NO. DATE
Michael Hurst Architect
LIGHTING COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
LT -1, LTG -2, LTG -3
Required F s
PRINCIPAL IGHTI DE IG E
SIGN TUt�a
LIC. NO.
DAT
LA
MECHANICAL COMPLIA
Indicate location on plans of Note Block for Mandatory Measures
MECH-1 MECH-2 MECH-3 MECH-5
Required rms
PRINCIPAL ME-CjiANIqALDESIGNER - AMESI
AT RE
LIC. NO.
c
DAFE
1,z1o�
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Paoe:3 of 21 1
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF -00
PROJECT NAME DATE
Just Java Coffee Shop TI I
9/12/2006
ENERGY COMPONENT
Space Heating
Space Cooling
Indoor Fans
Heat Rejection
Pumps & Misc.
Domestic Hot Water
Lighting
Receptacle
Process
TOTALS:
Standard
Design
9.33
503.86
0.00
0.00
0.00
0.00
72.s8
30.51
o.00
Percent better than Standard:
n4c no
Proposed
Design
1.28
427.55
0.00
0.00
0.00
0.00
151.85
30.51
0.00
A 44 I)n
Compliance
Margin
8.05
76.31
0.00
0.00
0.00
0.00
-78.88
0.00
o.00
rAa
Standard. Proposed
sr •+WIV
Conditioned Floor Area
Unconditioned Floor Area
Conditioned Footprint Area
Fuel Type
1,360
sqft.
sqft.
sqft.
�40 80 120,160,200 240 280 320 360 400440 480
kBtu/sgft-yr
):iCI
Hatt R*.§.n .;
Pump. & mi.
il
Natural Gas
. Raoepm le •:,...
0
0.9% ( 0.9% excluding process)
Building Orientation
Number of Stories
Number of Systems
Number of Zones
(S)180 deg
Conditioned Floor Area
Unconditioned Floor Area
Conditioned Footprint Area
Fuel Type
1,360
sqft.
sqft.
sqft.
1
0
2
1,360
il
Natural Gas
583
0
Orientation
Front Elevation S
Left Elevation (W)
Rear Elevation N
Right Elevation (E)
Total
Roof
Gross Area
sqft.
sqft.
sqft.
sqft.
sqft.
sqft.
Glazing Area
Glazing Ratio
sqft. 22.9%
sqft. 32.9%
sqft. 15.8%
sqft. 0.0%
sqft.
o.o°id
341
78
583
192
341
54
583
0
1,848
324
1,1os
0sqft.
Standard Proposed
Lighting Power Density 1.100 W/sqft. 2.289 W/sgft.
Prescriptive Env. Heat Loss 362 Btu/h 438 Btu/h
Prescriptive Env. Heat Gain 38,161 Btu/h-F 57,171 Btu/h-F
Remarks:
Standard Building (Compliance)
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: PageA of 21 1
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1
PROJECT NAME
Just Java Coffee Shop TI
DATE
9/12/2006
ZONE INFORMATION
Floor Inst.
_ Area • LPD
System Name Zone Name Occupancy Type (sgft.) (W/sf)1
Ctrl.
Credits
(W/sf)2
Allowed LPD
Proc.
Loads
(W/sf)
Area Tailored
(W/S3 (W/S4
4 Ton Unit Zone 1 Dining 1,360 2.08
- .A
Litemsab.ve
Notes: 1. See LTG -2-C 2. See LTG -4-C 3. See LTG -5-C 4. See LTG -6-C
(items marked with asterisk, see LTG -2 -C by others) . (by others)
require special documentation
EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST
The local enforcement agency should pay special attention to the Items specified in this checklist. These items require special written justification
and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of
the justification, and may reject a building or design that -otherwise complies based on the adequacy of the special justification and documentation
submitted.
The HVAC System "4 Ton Unit" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the MECH-5-A.
The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and
documentation for their use have been provided by the applicant.
Authorized Signature or Stam 4
Run Initiation Time: 09/12/06 17:29:15 Run Code: 1158107355
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:5 of 21
CERTIFICATE OF COMPLIANCE ENV -1-C
PROJECT NAME DATE
Just Java Coffee Shop TI 9/12/2006
OPAQUE SURFACES
#
Surface
Type
Area
U -Fac.
Insulation
Cay. Cont.
Act.
Am.
Tilt
Cond.
Status
Joint Appendix
IV Reference
Location / Comments
1
Roof
390
0.048
R-21
R-0.0
0
0
New
02-A6
Zone 1
2
Roof
716
0.036
R-30
R-0.0
0
0
Existing
02-A9
Zone 1
3
Wall
266
0.074
R-19
R-0.0
0
90
Existin
09-A5
Zone 1
4
Door
21
0.500
Insul
R-0.0
0
90
Existing
28-A3
Zone 1
5
lWall
1 583
0:074
R-19
R-0.0
90
90
Existin
09-A5
Zone 1
6
Wall
263
0.074
R-19
R-0.0
180
90
Existing
09-A5
Zone 1
7
Wall
391
0.074
R-19
R-0.0
270
90
Existing
09-A5
Zone 1
Existing
Double Metal Clear Default
Zone 1
9
Window
Left
54 0.870 NFRC
0.70 NFRC
270
Existing
Double Metal Clear Default
Zone 1
N, E. A. R (New, Existing, Altered, Removed)
FENESTRATION SURFACES
IMore then or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default LI -factors from
Standards Table 116-A and B. Certificate shall be filed in the contractor's project office during construction and in the building managers office after construction
#
IType
# Exterior Shade Type
Window Overhang Left Fin Right Fin
SHGC Hgt. Wd. Len. Hgt. LExt.RExt. Dist. Len. Hgt. Dist. Len. H t.
Area U -Fac'
SHGC2
Act.
Am.
Cond.
Stat.
Glazing Type
Location/
Comments
1
Window
Rear
N
54 0.870 NFRC
0.70 NFRC
0
Existing
Double Metal Clear Default
Zone 1
2
Window
Front
(S)
18 0.870 NFRC
0.70 NFRC
180
Existing
Double Metal Clear Default
Zone 1
3
Window
Front
(S)
42 0.870 NFRC
0.70 NFRC
180
Existing
Double Metal Clear Default
Zone 1
4
Window
Front
S
18 0.870 NFRC
0.70 NFRC
180
Existing
Double Metal Clear Default
Zone 1
5
Window
Left
21 0.870 NFRC
0.70 NFRC
270
New
I Double Metal Clear Default
Zone 1
6
Window
Left
(W)
21 0.870 NFRC
0.70 NFRC
270
New
Double Metal Clear Default
Zone 1
7
lWindow
Left
(W)
42 0.870 NFRC
0.70 INFIRC
270
Existing
Double Metal Clear Default
Zone 1
8
Window
Left
54 0.870 NFRC
0.70 NFRC
270
Existing
Double Metal Clear Default
Zone 1
9
Window
Left
54 0.870 NFRC
0.70 NFRC
270
Existing
Double Metal Clear Default
Zone 1
�1 LI -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value.
2 SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR SHADING
# Exterior Shade Type
Window Overhang Left Fin Right Fin
SHGC Hgt. Wd. Len. Hgt. LExt.RExt. Dist. Len. Hgt. Dist. Len. H t.
1 None
0.76
2 None
0.76
3 None
0.76
4 None
0.76
5 None
0.76
6 None
0.76
7 None
0.76
8 None
0.76
9 None
0.76
MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
The proposed building contains an enclosed space with floor area greater than 26,000 sq.ft, a ceiling height greater than 16 feet and a LPD for general lighting of at least 0.6 W/sq.ft. If this
box Is checked, ENV -4-C must be filled out when submitting under the Prescriptive Compliance Approach.
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:6 of 21 1
r
CERTIFICATE OF COMPLIANCE (Part 1 of 3) LTG -1 -C
PROJECT NAME DATE -
Just Java Coffee Shop TI 9/12/2006
INSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES
,. INSTALLED
WATTS
INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 2,841
PORTABLE LIGHTING (From LTG -3-C) 272
» LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-6) 0
' CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 3.11
INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0
LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0
UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0
ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES
❑ COMPLETE BUILDING METHOD (From LTG-5-C)ALLOWED
❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS
❑ TAILORED METHOD (From LTG -5-C) r ALLOWED LIGHTING POWER 3,113
ALTERNATE COMPLIANCE
❑X PERFORMANCE METHOD ,
❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) s
ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) o
MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS
CONTROL LOCATION
(Room #)
CONTROL
IDENTIFICATION
r t•
r �
CONTROL TYPE
(Auto Time Switch, Dimming, etc.)
•i •
Check if
SPACE CONTROLLED Daylighting
NOTE TO
FIELD
NOTES TO FIELD - For Building Department Use Only
Run Initiation Time: 09/12/06 17:29:15 -Run Code: 1158107355
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: - Page:7 of 21
CERTIFICATE OF COMPLIANCE (Part 3 of 3) LTG -
PROJECT NAME
Just Java Coffee Shop TI
DATE
9/12/2006
Designer:
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance
tests for lighting systems. The designer is required to check the boxes by all acceptance tests that
apply and list all equipment that require an acceptance test. If all equipment of a certain type requires
a test, list the equipment description and the number of systems to be tested in parentheses. The NJ
number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the
test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design
professional or an agent selected by the owner). Since this form will be part of the plans, completion
of this section will allow the responsible party to budget for the scope of work appropriately.
Building Departments:
Before an occupancy permit is granted for a newly constructed building or space, or a new lighting
system system serving a building or space is operated for normal use, all control devices serving the
building or space shall be certified as meeting the Acceptance Requirements for Code Compliance.
In addition a Certificate of Acceptance, LTG -1-A, Forms shall be submitted to the building department
that:
A. Certifies plans, specifications, installation certificates, and operating and maintenance
information meet the requirements of§ 10-103(b) and Title 24 Part 6.
Test Description
Test Performed By:
❑ LTG -2-A: Lighting Control Acceptance Document
- Occupancy Sensor Acceptance
- Manual Daylight Controls Acceptance
- Automatic Time Switch Control Acceptance
Equipment requiring acceptance testing
❑ LTG -3-A: Automatic Daylighting Controls Acceptance Document
Equipment requiring acceptance testing
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:8 of 21 1
CERTIFICATE OF COMPLIANCE MECH-1-C
PROJECT NAME DATE
Just Java Coffee Shop TI 1 9/12/2006
Designer:
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to
check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the
equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential
ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or -an agent
selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work
appropriately.
Building Departments:
SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a
building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for
Code Compliance.
In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation
certificates, and operating and maintenance information meet the requirements of Section 10-103(b) and Title 24 Part 6.
STATEMENT OF COMPLIANCE
❑ MECH-2-A: Ventilation System Acceptance Document
-Variable Air Volume Systems Outdoor Air Acceptance
-Constant Air Volume Systems Outdoor Air Acceptance
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit.
❑ MECH-3-A: Packaged HVAC Systems Acceptance Document
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit. -
❑ MECH-4-A: Air -Side Economizer Acceptance Document
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the
commission do not require equipment testing but do require construction inspection.
❑ MECH-5-A: Air Distribution Acceptance Document
Equipment requiring acceptance testing
This test required If the unit serves 5,000 V o1 space or less and 25% or more of the ducts are in nonconditioned or semiconditioned space like an
attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or
replace the packaged unit.
❑ MECH-6-A: Demand Control Ventilation Acceptance Document .,
Equipment requiring acceptance testing `
All new DCV controls installed on new or existing packaged systems must be tested.
❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document
Equipment requiring acceptance testing
All new VA fan volume controls installed on new or existing systems must be tested
❑ MECH-8-A: -Hydronic System Control Acceptance Document
-Variable Flow Controls Applies to chilled and hot water systems.
-Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header.
-Supply Water Temperature Reset Controls
Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btulbr.
,
-Water-loop Heat Pump Controls
Applies to all new watertoop heat pump systems where the combined loop pumps are greater than 5 hp. -
-Variable Frequency Controls Applies to all new distribution pumps on new variable.fiow chilled, hydronic heat pump
or condenser water systems where the pumps motors are greater than 5 hp.
Equipment requiring acceptance testing
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:9 of 21
INDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG -2-C
PROJECT NAME DATE
Just Java Coffee Shop TI 9/12/2006
INSTALLED LIGHTING POWER FOR CONDITIONED SPACES
Luminaire
Lamps/Ballasts
Installed Watts
C
D
E
F
G
H
I
J
Name
Type Description
�y
�3
(D-p
cdc
3,33
�yCD
N N
fD N O
ori��
39Da
��y.
co_Wic
3.iv3
ED
0)
N N
f !� O
c
3v�
���
L N
@sNo
ofD�im
c
-Ci
•J
r-
c -Z
5•o3
T.
-
N
=a)
x�—
vNfD
d
(1) 4 ft Fluorescent T8 MagEE
F32T8
1
32
1.01
39.0
X
1
39
(1) 8" Circline
C8_T_9
1
22
1.0
27.0
X
3
81
(2) 4 ft Fluorescent T12 ES
40T12/ES
2
34
1.0
82.0
X
3
246
75w Hanging Incandescent
Sow
1
50
50.0
X
18
900
75w Recessed Incandescent
5
1
75
75.0
X
21
1.575
PAGE TOTAL 2 841
BUILDING TOTAL (sum of all pages) 2,841
PORTABLE LIGHTING (From LTG -3-C) 272
CONTROL CREDIT (From LTG -4-C) D
ADJUSTED ACTUAL WATTS 3 113
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Pew: 10 of 21 1
PORTABLE LIGHTING WORKSHEET LTG -3-C
PROJECT NAME
Just Java Coffee Shop TI
DATE
9/12/2006
A B
BUILDING TOTAL
TABLE 1 - PORTABLE LIGHTING NOT SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET
A B
C
D
ROOM # DEFAULT
OR ZONE ID W/sqJ
AREA
(SF)
TOTAL WATTS
(B X C)
Zone 1 0.2
1,360
272
TOTAL
1,360
272
TABLE 2 - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE
FEET
A B
BUILDING TOTAL
C
D E
F
G
ROOM # PORTABLE LIGHTING
OR ZONE ID Description
# OF
FIXT.
LUMIN.
WATTS PER
FIXTURE
TASK # OF
AREA TASK
(SF) AREAS
TOTAL
AREA (SF)
(D x E)
TOTAL
WATTS
(C x E)
TOTAL
0
0
TABLE 3 - PLANS SHOW PORTABLE LIGHTING IS NOT REQUIRED FOR OFFICE AREAS > 250 SQUARE FEET
ROOM # TOTAL AREA
OR ZONE ID (SF)
TOTALI 0
BUILDING SUMMARY - PORTABLE LIGHTING
Designer needs to provide detailed documentation that the lighting
level provided by the overhead lighting meets the needs of the
space. The details Include luminaire types and mounting locations
relative to work areas.
BUILDING SUMMARY
TOTAL AREA (SF)
(FROM TABLES 1+2+3)
TOTAL WATTS
BUILDING TOTAL
1,360
272
Run Initiation Time: 09/12/06 17:29:15 Run Code: 1158107355
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 11 of 21
AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C
PROJECT NAME ' DATE
Just Java Coffee Shop TI E : 9/12/2006
SYSTEM FEATURES
AIR SYSTEMS, Central or Single Zone
ITEM OR SYSTEM TAG(S)' ' : ' , 4 Ton Unit
Number of Systems 2 '
T-24
MANDATORY MEASURES Section Reference on Plans or Specification 1
Heating Equipment Efficiency
Cooling Equipment Efficiency
Heat Pump Thermostat
Furnace Controls
Natural Ventilation
Minimum Ventilation
VAV Minimum Position Control
Demand Control Ventilation
Time Control
Setback and Setup Control
Outdoor Damper Control
Isolation Zones
Pipe Insulation
Duct Insulation '
112(a) .-
7.20 HSPF
112(a)
13.0 SEER / 9.0 EER
112(b)
'Yes
112(c), 115(a)
n/a
121(b)
Yes'
{
121(b)
204 cfm
121 c s
No
s
121(c)
No "+ .
121(p)1_2 2 (pj
Programmable Switch
122(e) _
Heating & Cooling Required
"
122
< < Auto
122(8)
r ri/a
123
124
,.
R-4.2
PRESCRIPTIVE MEASURES
Calculated Heating Capacity x 1.43 2
Proposed Heating Capacity 2
Calculated Sensible Cooling Capacity x 1.212
Proposed Sensible Cooling Capacity 2
Fan Control
DP Sensor Location
Supply Pressure Reset (DDC only)
Simultaneous Heat/Cool
Economizer
Heating Air Supply Reset
Cooling Air Supply Reset
Duct Sealing for Prescriptive Compliance
144 a & b
n/a
144 a & b
0 btuh
144 a & b
n/a "
144 a & b
97,113 btuh
144 c
Constant Volume
144 (c)
144 (c),
z- Yes '
144 d
No
144 a
No Economizer
144
Constant Tem
"
1144(f)
Constant -Temp
144 (k)
No '
1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the
required features are documented. If a requirement is not applicable, put "N/A" in the column.
2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1.
3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25%_ duct in unconditioned space. Duct sealing is required for Prescriptive Compliance,
see PERF -1 for performance method duct sealing requirements.
INOTES TO FIELD - For Buildina Department Use OnIV
Rnn llnifinfinn Timn- n0/49/na 47.90.4C 0— !`".d".• 44C44n74CC
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 12 of 21
P
MECHANICAL VENTILATION MECH-3-C
PROJECT NAME
TI
DATE
PRESCRIPTIVE REHEAT
LIMITATION (Section 144(d))
MECHANICAL VENTILATION Section 121 (b)2)
AREA BASIS
OCCUPANCY BASIS
VAV MINIMUM
A
B
C
D
E
F
G
H
I
J
K
L
M
N
ZONEISYSTEM
0
D�
vA G
;
W
a
ori' n
1D T
°o ' 3
..
Cr3
Oo`�
X D n
d 3
c
3
O Q
°
�� n
tIZ A T
' 1 3
�3
m��
X n
�? 3
,.
m
0W D
X O
ci D
c
n� ego
T :'* N
3 D'
po
o
n0 0
T (/� O
3� `"
n
3T�
c' O
a
o2
c—
w3 o3i
O X
T =
3
vim
CD
O 3
' '
D
r'n
r
Zone 1
1,36C
0.50
680
680
204
476
4 Ton Unit
Total
680
204
i e t' t e
E Based on fixed seat or the realer of the expected number of occupants and 50% of the CBC occupant load for egress purposes for spaces without fixed seating.
H Required Ventilation Air REO'D V.A. is the la[ger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS column D or G).
I Must be greater than orequal to H or use Transfer Air column N to make up the difference.
J Design fan supply aim Fan CFM x 30%; or
K Condition area ft. s x 04 cfm/ft. sq.* or
L Maximum of Columns H, J. K, or 300 cfm
M This must be less than or equal to Column L and greater that or equal to the sum of Columns H + N.
N Transfer air must be provided where the Required Ventilation Air (column H) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or
equal to the difference between the Required Ventilation Air (column H) and the Design Minimum Air (column M), column H - M.
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 13 of 21
MECHANICAL EQUIPMENT DETAILS
Part 1 of 2 MECH-5-C
PROJECT NAME
Just Java Coffee ShopTI
DATE
9/12/2006
CHILLER AND TOWER SUMMARY
System Type
Distribution Type
Efficiency
Tons
PUMPS
Condition
Status
Ext.
R -Val.
Equipment Name
Equipment Type
Qty.
Tot.
Qty
GPM
BHP
Motor
Eff.
Drive
Eff.
Pump
Control
HWBOILER
Hot Water P mp Hot Water Piping. Length ft
Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
CENTRAL SYSTEM RATINGS
HEATING COOLING
Aux. Condition
System Name System Type Q Output kW Eff. Output Efficiency Status Economizer Ty -!?e -
4
y e4 Ton Unit Packaged OX 2 0 0.0 7.20 HSPF 59,000 13.0 SEER / 9.0 EER New No Economizer
Energy
Factor
or RE
Standby
Loss or
Pilot
TANK INSUL.
System Name
System Type
Distribution Type
Qty
Rated
Input
Vol.
(Gals.)
Condition
Status
Ext.
R -Val.
Hot Water P mp Hot Water Piping. Length ft
Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
CENTRAL SYSTEM RATINGS
HEATING COOLING
Aux. Condition
System Name System Type Q Output kW Eff. Output Efficiency Status Economizer Ty -!?e -
4
y e4 Ton Unit Packaged OX 2 0 0.0 7.20 HSPF 59,000 13.0 SEER / 9.0 EER New No Economizer
MECHANICAL EQUIPMENT DETAILS Part 2 of 2 MECH-5-C
PROJECT NAME DATE
Just Java Coffee Shop TI I 9/12/2006
VAV TERMINAL BOX TERMINAL FAN BASEBOARD
Min. CFM h ColMotor Drive
y_Stem Tvp ty. Ratio T e DeltaT CFM BHP Eff. Eff. Type Output
EXHAUST
FAN
EXHAUST
FAN
Room Name
qty.
CFM
BHP
Motor
Eff.
Drive
Eff.
Room Name
Qty.
CFM
BHP
Motor
Eff.
Drive
Eff.
Zone 1
1.0
115
0.00
40.00/c
97.0%
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Pagel5 of 21
ENVELOPE MANDATORY MEASURES ENV -MM
PROJECT NAME DATE7
Just Java Coffee Shop TI 9/12/2006
k •
DESCRIPTION �'
Desi ner
Enforcement
❑X
§ 118(a)
Installed Insulating Material shall have been certified by the manufacturer to comply
with the California Quality Standards for insulating material, Title 20, Chapter 4, Article
3.
X
§ 118(c)
All Insulating Materials shall be installed In compliance with the flame spread rating
and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2.
0
§ 117(a)
All Exterior Joints and openings in the building that are observable sources of air
leakage shall be caulked, gasketed, weatherstripped or otherwise sealed.
X❑
§ 116(b)
Site Constructed Doors, Windows and Skylights shall be caulked between the unit
and the building, and shall be weatherstrlpped (except for unframed glass doors and
fire doors).
X❑
§ 116(a)1
Manufactured Doors and Windows installed shall have air Infiltration rates not :
exceeding those shown in Table Number 1-E. of the Standards. Manufactured
fenestration products must be labeled for U -value according to NFRC procedures.
X❑
§118(e)
Demising Walls in Nonresidential Buildings:
The opaque portions of framed demising walls in nonresidential buildings shall have
Insulation with an installed R -value of no less than R-13 between framing members.
-+ a
EnergyPro
By EnergySoft User Number: User Job Number. Page: 16 of 21
k •
�
LIGHTING MANDATORY MEASURES � LTG -MM
PROJECT NAME DATE
Just Java Coffee Shop TI 9/12/2006
DESCRIPTION
Designer
Enforcement
X] §131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic
control to shut off the lighting. This automatic control shall meet the requirements of
Section 119 and may be an occupancy sensor, automatic time switch, or other device
capable of automaticallishutting off the lighting.
n §131(d)20verride for Building Lighting Shut-off: The automatic building shut-off system is '
provided with a manual, accessible override switch in sight of the lights. The area
of override is not to exceed 5,000 square feet.
§119(h) Automatic Control Devices Certified: All automatic control devices specified are
certified, all alternate equipment shall be certified and installed as directed by the
manufacturer. ;
X❑ §111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for
the project are certified and listed in the Directory. All installed fixtures shall be
certified.
§132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three
lamp fluorescent fixtures are tandem wired with two lamp ballasts where required
by Standards Section 132; or all one and three lamp fluorescent fixtures are '.
specified with electronic high -frequency ballasts and are exempt from tandem
wiring requirements.' -
X❑ §131(a) Individual Room/Area Controls: Each room and area in this building is equipped
with a separate switch or occupancy sensor device for each area with floor -to -
ceiling walls.
§131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100
square feet and more than 0.8 watts per square foot of lighting load shall be
controlled with bi-level switching for uniform reduction of lighting within the room.
n §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than
250 square feet and that allow for the effective use of daylight in the area shall
have 50% of the lamps 'in each daylit area controlled by a separate switch; or the
effective use of daylight cannot be accomplished because the windows are,
continuously shaded by a building on the adjacent lot. Diagram of shading during
different times of the year is included on plans. "
§131(e) Display Lighting. Display lighting shall be separately switched on circuits that
are 20 amps or less.
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 17 of 21
MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM
PROJECT NAME DATE
Just Java Coffee Shop TI 1 9/12/2006
DESCRIPTION
Desi ner
Enforcement
Equipment and Systems Efficiencies
❑X §111 Any appliance for which there is a California standard established in the Appliance
Efficiency Regulations will comply with the applicable standard.
§ 115(a) Fan type central furnaces shall not have a pilot light.
X❑ § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees
Fahrenheit, or within HVAC equipment, shall be insulated In accordance with
Standards Section 123.
X❑ § 124 Air handling duct systems shall be installed and insulated In compliance with
Sections 601, 602, 603, 604, and 605 of the 2001 CMC Standards.
Controls
§ 122(e) Each space conditioning system shall be installed with one of the following:
X] § 122(e)1A Each space conditioning system serving building types such as offices and
manufacturing facilities (and all others not explicitly exempt from the requirements
of Section 112 (d)) shall be installed with an automatic time switch with an
accessible manual override that allows operation of the system during off -hours for
up to 4 hours. The time switch shall be capable of programming different
schedules for weekdays and weekends and have program backup capabilities that
prevent the loss of the device's program and time setting for at least 10 hours if
power Is Interrupted; or
F] § 122(e)1 B An occupancy sensor to control the operating period of the system; or
§ 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the
system.
X❑ § 122(e)2 Each space conditioning system shall be Installed with controls that temporarily
restart and temporarily operate the system as required to maintain a setback
heating and/or a setup cooling thermostat setpoint
❑ § 122(g) Each space conditioning system serving multiple zones with a combined
conditioned floor area more than 25,000 square feet shall be provided with isolation
zones. Each zone: shall not exceed 25,000 square feet; shall be provided with
Isolation devices, such as valves or dampers, that allow the supply of heating or
cooling to be setback or shut off Independently of other Isolation areas; and shall
be controlled by a time control device as described above.
§ 122(a&b) Each space conditioning system shall be controlled by an Individual thermostat
that responds to temperature within the zone. Where used to control heating, the
control shall be adjustable down to 55 degrees F or lower. For cooling, the control
shall be adjustable up to 85 degrees F or higher. Where used for both heating and
cooling, the control shall be capable of providing a deadband of at least 5 degrees
F within which the supply of heating and cooling is shut off or reduced to a
minimum.
XJ § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable
setpoint stops accessible only to authorized personnel.
§ 112(b) Heat pumps shall be installed with controls to prevent electric resistance
supplementary heater operation when the heating load can be met by the heat
pump alone.
EnergyPro By EnergySoft User Number: User Job Number: Page: 18 of 21
MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM
PROJECT NAME
r 'DATE
Just Java Coffee Shop TI 9/12/2006
Description
Designer
Enforcement
Ventilation
❑X
§ 121(e)
Controls shall be provided to allow outside air dampers or devices to be operated at
the ventilation rates as specified on these plans.
X]
§ 122(f)
Gravity or automatic dampers interlocked and closed on fan shutdown shall be
provided on the outside air intakes and discharges of all space conditioning and
exhaust systems.
X❑
§ 122(q
All gravity ventilating systems shall be provided with automatic or readily accessible
manually operated dampers in all openings to the outside, except for combustion air
openings.
❑
§ 121(f)1
Air Balancing: The system shall be balanced in accordance with the National
Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or
Associated Air Balance Council (AABC) National Standards (1989); or
X
§ 121(f)2
Outside Air Certification: The system shall provide the minimum outside air as
shown on the mechanical drawings, and shall be measured and certified by the
Installing licensed C-20 mechanical contractor and certified by (1) the design
mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the
person with overall responsibility for the design of the ventilation system; or
§ 121(f)3
Outside Air Measurement: The system shall be equipped with a calibrated local or
remote device capable of measuring the quantity of outside air on a continuous
basis and displaying that quantity on a readily accessible display divlce; or
§ 121(04
Another method approved by the Commission. a °#
Service Water Heating Systems
§ 113(b)2
If a circulating hot water system is installed, It shall have a control capable of
automatically turning off the circulating pump(s) when hot water Is not required.
1A I
§ 113(c)
Lavatories in restrooms of public facilities shall be equipped with controls to limit the
outlet temperature to 110 degrees F. ,
J Y +
EnergyPro
By EnergySoft User Number: User Job Number: Page: 19 of 21
' 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Just Java Coffee Shop TI 9/12/2006
SYSTEM NAME FLOOR AREA
4 Ton Unit 1,360
Number of Systems
2
Heating System
Output per System
0
Total Output (Btuh)
0
Output (Btuhlsgft)
0.0
Cooling System
Output per System
59,000
Total Output(Btuh)
118,000
Total Output (Tons)
9.8
Total Output (Btuh/sgft)
86.8
Total Output (sgft/Ton)
138.3
Air System
CFM per System
1,600
Airflow (cfm)
3,200
Airflow (cfmisgft)
2.35
Airflow (cfm/Ton)
325.4
Outside Air (%)
6.4
Outside Air (cfm/sgft)
0.15
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensiblel
Latent
I CFM
I Sensible
2,083
54,544
2,720
595
25,112
0
2,727
1,256
0
0
204
7,855
6,053
204
9,472
0
0
2,727
1,256
67,853 8,773
4 Ton Unit 97,113 0 0
Total Adjusted System Output97113 0
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 4 pm I Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0 of 66.8 of 110.0 of 110.0 of
.01 011 Supply Air Ducts
Outside Air
204 cfm o
Heating Coil Supply Fan 109.6 F
3200 cfm ROOMS
70.0 of
69.6 of
f% Return Air Ducts `i
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0 / 77.6 of 77.1 / 59.9 of 48.6 / 47.2 of 48.6 / 47.2 of
Supply Air Ducts
Outside Air O
204 cfm Cooling Coil Supply Fan 49.4 / 47.6 of
3200 cfm 37.6% R.H. ROOMS
74.8/58.3 of 74.0 / 58.0 of
K Return Air Ducts `i
EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:20 of 21
ROOM LOAD SUMMARY
PROJECT NAME
DATE
Just Java Coffee Shop TI
9/12/2006
SYSTEM NAME
FLOOR AREA
4 Ton Unit
1,360
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE
Zone 1
Zone 1 1 2,083 54,544 2,720 2,083 54,544 2,720 595 25,112
:F
PAGE TOTAL 1 2,083 54,544 2,720 595 25,112
TOTAL 2,083 54,544 ' 2,720 595 X25,112
EnergyPro By EnergySoft User Number: User Job Number: Page:21 of 21
l
:F
PAGE TOTAL 1 2,083 54,544 2,720 595 25,112
TOTAL 2,083 54,544 ' 2,720 595 X25,112
EnergyPro By EnergySoft User Number: User Job Number: Page:21 of 21
1
♦ L 1r �te7
oiw tin
I4 G
��.+
2
jr2lac
Z� r
AR
PEL y F
CITY 01 LA QUINI"A SN . -100
6 BUILDING & SAFETY DEPT.
�aN
APPROVED'.:,
FOR CONSTRUCTION SOF CA oP
A4- /�
MTV
'CITY OF LA QU . INTA'
BUILDING & SAFETY DEPT.
APPROVED',
FOR -CONSTRUCTION
DA kA gy
L
No. -100