Loading...
06-2697 (CSCS)' P.O. BOX 1504 78-495 CALLE TAMPICO LA-QUINTA, CALIFORNIA 92253 4Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: IZO.6-=0.0.002697 Property Address: 46520 WASHINGTON ST APN: 643-020-999-3 -30903 - Application description: NEW COMML - STORES & CUSTOMER SERVICE Property Zoning: REGIONAL COMMERCIAL Application valuation: 414609 Applicant: Architect or Engineer: Owner: WASHINGTON 111 LTD C/O JACK TARR 30240 RANCHO VIEJO RD. STE. B SAN JUAN CAPISTRANO, CA 92675 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Contractor: W L BUTLER CONSTRUCTION, IN 7 "GOODYEAR D IRVINE, CA 92618 (949)587-2206 Lic. No.:.355353 Date: 11/30/06 NOV 3 0 2006 OF LA - - LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter.9 (commencing with. I hereby affirm under penalty of perjury one of the following declarations: , Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: B License No.: 355353 - for by Section 3700 of the Labor Code, for the performance of the work for which this permit is _ - issued. ..e: Coro _ — I have and will maintain workers' compensation insurance, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My'workers' compensation ' OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: 'Any city or county that requires a permit to - construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code).or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and • the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (x) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. T-' 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERD11T insurance carrier and policy number are: Carrier ABD INS Policy Number 71WC12012701 /� 1 certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, IIt f �shaorthwith comply with those provisions. G � Date ' J� �. cant: jL%:� WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND • DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for, a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for ins tion purposes. Date:.. Signature (Appgcant--o-orA gent): ^—� 6,��u�►, _�����rd Application Number . .. 06-00002697 ------ Structure Information SHELL BLDG B/M/A-3 OCC. ----- Other struct info CODE EDITION 01BMP04E05EN FIRE SPRINKLERS YES MIXED-USE OCCUPANCY SHELL B/M/A-3 OCCUPANT LOAD .00 PATIO SQ FTG 1772.00 1ST FLOOR SQUARE FOOTAGE 5263.00 2ND FLOOR SQUARE FOOTAGE .00 Permit BUILDING PERMIT Additional desc SHELL BLDG B/M/A-3 OCCUPANCIES Permit Fee . . . . 1742'.00. Plan Check Fee 1132.30 Issue Date. . . Valuation 414609 Expiration Date .. 5/29/07 Qty Unit Charge Per Extension BASE FEE- 639.50 315.00 3.5000 THOU jPLDG 100',001-500,000 1102.50 Permit . . . ELEC-NEW COMMERCIAL Additional desc ., Permit Fee '120.26 Plan Check Fee 30.07 Issue Date Valuation . . . . 0 Expiration Date.. 5/29./07 Qty . Unit Charge Per - Extension BASE"FEE 15.00 5263.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL, ------------- 105.26- Permit MECHANICAL. Additional desc . Permit Fee . . . . 64.00 Plan Check Fee 16.00 Issue Date . . . . Valuation .. . . . 0 Expiration Date 5/29/07. Qty Unit Charge Per Extension BASE FEE 15.00. 2.00 9.0000 EA' MECH FURNACE <=100K 18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU ? 18.00 2.00 6.5000 EA MECH VENT FAN 13.00 Permit PLUMBING Additional desc . LQPER-,IIT Application Number . . . . . 06-00002697 Permit . . . .. PLUMBING Permit Fee . . . . 208.50 Plan Check Fee '. 52.13 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/29/07 Qty Unit Charge Per Extension BASE FEE 15.00 6.00 6.0000 EA PLB FIXTURE 36.00 3.00 15,.0000 EA PLB BUILDING.SEWER 45.00 2.00 6.0000 EA PLB ROOF DRAIN 12.00 2.00 7.5000"EA PLB WATER HEATER/VENT 15.00 3.00 3.0000 EA PLB WATER INST/ALT/REP 9.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 3.00 7.5000 EA PLB OTHER BACKFLOW <=2 INCH 22.50 3..00 15.0000 EA PLB GAS METER 45.00 Permit . . ._ GRADING PERMIT Additional.desc . Permit Fee. 15.00 , Plan Check Fee- .00 _ " Issue Date Valuation 0 Expiration'Date". 5/29/07 Qty Unit.Charge Per Extension BASE FEE 15.00 . Special Notes and Comments 5,263 SF BUILDING SHELL(@ PAD 6)TYPE V-N CONSTR.(B/M/A-3 PROPOSED OCCUPANCIES) 2001 CBC,CMC,CPC, 2004 CEC, 2005 ENERGY CODES. **PERMIT DOES . NOT INCLUDE TEMPORARY POWER, BLOCK WALLS, TRASH ENCLOSURE,-GREASE INTERCEPTOR AND SITE LIGHTING.*., 2005 DIF ASSESSED. Other Fees . . . . . ACCESSIBILITY PLAN REVIEW 113.23 ART'IN PUBLIC PLACES-COM 2053.04 . DIF CIVIC CENTER - COMM 821.02 ENERGY REVIEW FEE 113.23 DIF FIRE PROTECTION-COMM 236.83 STRONG MOTION (SMI) - COM 87.06 DIF STREET MAINT FAC-COMM 557.87 DIF TRANSPORTATION - COMM 13852.21 Fee summary Charged Paid Credited -------------------- Due ----------------------- --- ---------- Permit Fee Total 2149.76 .00 .00 2149.76 LQPEILNIIT LQPE%NIIT Din # P�� 6 City of La Quint a* Building U Safety Division P mit � S °'� 5 P.O. Box 1504, 78-495 Calle Tampico 6 2 6 % % La Quinta, CA 92253 - (760) 777-7012 b Building Permit Application and Tracking Sheet roject Address:' L%G _ / oN 5/ Owner's Name: 541.11 1v0 ` �// L %1j A. P. Number: Address: 3-02y0 –City, Zip:Qk Legal Description: Ci ST�+ Contractor: Telephone: `3 2 Address: Project Description: City, ST, Zip: Telephone: State Lic. # : City Lic. #: Arch., Engr., Designer: k K Address: City, ST, Zip: Telephone: State Lic. #: Construction Type: Occupancy: P cY: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: �ji �� JC,HG BZ Sq. Ft.: # •Stories: —# units: Estimated Value of Project: Telephone # of Contact Person: 3 i �Z-Z6N APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Plan Sets Req'd Reed TRACKING . Plan Check submitted Z PERMIT FEES Item Amount . Structural Cales. Reviewed, ready for corrections 1.1 Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Cales. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading, pliin 2'' Review, ready for correction ue 2 �, Electrical SubcoutactorList Called Contact Person ?% Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for. corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue 3 School Fees Total Permit Fees 11 CAII .215107 CDD �qPPRov6P*rway I February 21, 2007 .760-775=7967 Phone 760-775-8329 Fax City of. -La Quinta, -Building, and Safety Department 78=495. Calle Tampico PO'Box 150,4 La.Quinta, CA -9253 RE: Revisions to 46-520 Washington Street (Pad 6) To Whom It May Concern: k Washington 111, LTD is tequestmg approval to -make the "folldwing modification, Suite 1 of Pad"6. 1. Relocate restroom to match Tenant Improvement layout.. 2. Add. side exit door to -meet Tenant .Improvement's exiting requirements. ' These modification -are being made to the permittedshell plans -to satisfy the Tenant Improvement exiting requirements and restroom configuration. Please _call me -should you have any -:questions. ..,Sincerely, t Bill''Sanchez, Construction Manager Washington 111, LTD a tIG1�CV P.O. BOX 1504 BUILDING & SAFETY DEPARTMENT 78-495 CALLE TAMPICo (760) 777-7012 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 Finance Department, Please Collect The Following Fees For The Services Rendered HTE APPLICATION No, 06-2697 PROJECT: SHELL BUILDING PAD 6 ADDRESS: 46-520 WASHINGTONS.ST: CUSTOMER: WASHINGTON 111 LTD. SERVICES RENDERED: REVISE SHELL -BUILDING SUITE#1 'Fees: Plan Review:. .... ......... ....................... . ... .......... .. $ 70.00 (2 X $35/hr) TOTAL FEES NOW DUE:................. ................$ 70.00 Date: 2/26/07 Initials:_JLJ CIT OF LA QUINTA BUILDING & SAFETY DEFT. APPROVED. FOR CONSTRUCTION DAT O B � - Y'ax ✓' :h. tis � .-_.. J.ok rY. i"...., _ .:: t.-4 i _. . l 17 -- ht"vv.. `"t+_ �i" -: ^w K`• ^r'4 aiy4r� 1 Zf, ,_ t L Lz :�. o.z' y, .. ^%: -' .ti iXs +'f+ , _ ". .r.. r �+'ti� :✓-* (t {s The Cornerstone Group M 7. PSALMS 118:22-24 r j '0 toblkl- 13,Y2006Y .'•, " ` a� Engineering 'r r 4, Planning .'..Surveying} r CITY OF 4LA QUINTA tt78;495"Calle =Tampico. Quinta {�U ,CA `92253` , r, { . k2 Attertion<, Mr Timothy R: Jonasson;•P E'. r ` `Public 1NocksDirector/City' Engineer"'" �• t , . k' RE: ' WASHINTON RARK`� - SFr PHASE'3B{ 's r ! I �� _r OF PARCELS 5 10 xPARGELMAP 32683E rPRECISE 'GRA V` DWG NO'F"PG3,054Q501 1485 Spruce -Street Su{teFHa N Dear` Mr 'Jonasson t K Riverside, CA 92507• Y=y 'PrWe lereby;certify that f eld venfication,of the-above°referencedsite has:been t r + y sr a x 95.1.342:0036 T' le r y} }performed undeb-rny;supervision. and that theyas built elelations,of the building pads are m substan_ tial ccnformancewith'tle Precise�Gradng Flare. n " . 951 342.0268Fax Please refer to the table:beloW for the°specifics'of�tliis ce.rtificafion. ' %^. k Y' � Pad No Plan Elevation field Elevation' Difference .� Pad 6 70 005 QROFES /o�:. 70.05 05 + r QUO SES E •., } .5 % No. 28248, m ;= s. The Col &st ne Group P• 3-3108 4s `ell E Sharp; X. E. 28248" e` Director�of:Engirieering .; X'.\Amanda\Certifications\4976-WLButl`r.WashParkPh3:Sublvlajor5 Pdoc �•' `n �r`v.P,ks Y ��. a'L. g,„. 'r':, >`.a.ef � G .�: .� •t� ]. r �= f :i"� r !r` y s`°i sa'�x- s. .� t'� � � ,r�. ..?s .. ,; _ . �.x �.'±r _ .ss : s.. a,. _.' e. .... :_. •.. _ . , ,'wCi9•�'.�`,.� 4� ��'ar_+�t'_.� ^:• �> r�..k".�-+` v } I, Craig E. Anthony Fire Chief Proudly serving the Unincorporated areas of Riverside County and the + Cities of Benning Beaumont Calimesa O Canyon Lake Coachella O Desert Hot Springs r. Indian Wells a Indio Lake Elsinore La Quinta w Moreno Valley �r Palm Desert' O Penis Rancho Mirage San Jacinto Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District S RIVERSIDE COUNTY FIRE DEPARTMENT 82-675 Highways 111, 2"d• Fl., Indio, G1 92201 • (760) 863.8886 . Fax (760) 863-7072 May 23, 2005 To: City of La Quints Building Department Re: Release for Permit Laq-05-BP-042 / Pad 6 The Riverside County Fire Department hereby releases the above referenced project for issuance of a permit for construction, at the discretion of the Building Department. Respectfully, T Dale A. Evenson Fre Safety Specialist Y l EMERGENCY SE1t1lICPS DIVISLON • PLANNING SECTION • II0I0 OFFICE 82-675110may 111, 2"s A., Irdb, CA 92201 • (760) 863-8886 • Fax (760) 863-7072 Craig E. Anthony Fire Chief Proudly serving the unincorporated areas of Riverside County and the Cities of. Banning ee Beaumont 0 Calimesa ee Canyon Lake Coachella 4. Desert Hot Springs c• Indian Wells e• Indio O Lake Elsinore ee La Quinta ee Moreno Valley ee Palm Desert Perris Rancho Mirage eo San Jacinto ee Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT May 17, 2005 KKE Architects, Inc. 20321 SW Birch Street Newport Beach, CA 92660 Re: ' Non -Structural Building Plan Review LAQ-05-BP-042(/ 46=520 Washington St. Y'a Fire Department personnel have reviewed and approved the plans you submitted for the above referenced project. Please be advised the following conditions apply as a part of the conditions for the issuance of a building permit 1) These conditions are for a shell building and will receive a shell final only. No fire and life safety clearance will be issued for a tenant space until the specific occupancy classification has been established and tenant improvement plans have been reviewed and conditioned by the Riverside County Fire Department. 2) Fre Department approval is based upon the 2001 CBC requirements for Group B or M occupancies. It is prohibited to use, process or store any materials in the occupancy that would classify it as a Group H occupancy per Sec. 307 of the 2001 CBC. 3) The Fire Department is required to seta minimum fire flow for the remodel or construction of all commercial buildings using the procedure established in the 2001 CFC. A fire flow of 1500 gpm for a 2 -hour duration at 20 psi residual operating pressure must be available before any combustible material is placed on the job site. 4) The required fire flow shall be available from a Super hydrant(s) (6"x 4" x 21/2" x 21/2') located not less than 25' or more than 165' from any portion of the building(s) as measured along approved vehicular travel ways. 5) Install a complete fire sprinkler system per NFPA 13. The post indicator valve and fire department connection shall be located to the front within 25' to 50' of a hydrant, and a minimum of 25' from the building. System plans must be submitted to the Fire Department for review, along with a planfinspection fee. The approved plans, with Fire Department Job card must be at the job site for all inspections. 6) Install an alarm monitoring system for fire sprinkler system(s) with 100 or more heads (20 or more in Group I, Division 1.1 and 1.2 occupancies). Valve monitoring, water -flow alarm and trouble signals shall be automatically transmitted to an approved central station, remote station or proprietary monitoring station in accordance with 2001 CBC, Sec. 904.3.1. An approved audible sprinkler flow alarm shall be provided on the exterior in an approved location and also in the interior in a normally occupied location. A C-10 licensed contractor must submit plans, designed in accordance with NFPA 72, 1999 Edition, to the Fire Department for review and approval prior to installation. 7) Install Knox Key Lock box, Model 3200, mounted per recommended standard of the Knox Company. If the building/facility is protected with a fire alarm system or burglar alarm system, the lock boxes will require "tamper'" monitoring. Special forms are available from this office for the ordering of the Key Switch. This form must be authorized and signed by this office for the correctly coded system to be purchased. EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2"d FI., Irdo, CA 92201 • (760) 863-8886 • Fax (760) 863-7072 8) All egress doors shall comply with CBC. Sec. 1003.3.1.8 for proper door hardware. 9) Install portable fire extinguishers per Title 19, but not less than 2A10BC in rating. Contact certified extinguisher company for proper placement of equipment. 10) Approved building address shall be placed in such a position as to be plainly visible and legible from the street and rear access if applicable. Building address numbers shall be a minimum of 12" for building(s) up to 25' in height, and 24" in height for building(s) exceeding 25' in height. In multi -tenant buildings, businesses shall post the business name and suite number on back doors as well as the front. Suite numbers or letters must be a minimum of 6" in height. All addressing must be legible and of a contrasting color with the background. Please contact the Fire Department Planning & Engineering staff for final inspection. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760) 863- 8886. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Sincerely, FRANK KAWASAKI Chief Fire Department Planner By Walter Brandes Fire Safety Specialist Cc: City of La Quinta - Building Dept �`,�...,,....y�„�..• ”' . �,,.. .. r...�-ate. •1••},e•i.Y,,.-•+•.�,1,`�.m' h`rt..�„-L:.+'r1�,.,��'",..--•.,.,,••.�-..r.T�w_ � .-«..,,�../L�•+r+,�-s./,�,.• —�. TANDY'S INSPECTION SERVICES, INC. PO BOX 13766 - PALM DESERT, CA 92255-3766 "r OFFICE/FAX-951.769.9717 PAGER -760.776.3339 SPECIAL INSPECTION EPDXY REPORT TYPE OF INSPECTION PERFORMED EPDXYlzt��06�.6c17 PERMIT NUMBER TYPE OF STRUCTURE DATE / 2 COMMERCIAL RESIDENTIAL I I - 1 PHYSICAL ADDRESS (INCLUDE STREET NAE AND aryl Y 6 _. SZ d W115 F/ N G70/�/ 5 % JOB NAME (INCLUDE LOT NUMBER / NAME OF COUNTRY CLUB/BUS NESS PARI /CORPORATE CENTER... ECT?) WP5 P A/ 7-e AJPfl1de 14 .. 3 L DU 6 ARCHITECT K ENGINEER ' i< L_ GENERAL CONTRACTOR UJ C.. ' NT / E !D_ SUB CONTRACTOR .D rG Nr PC, . DESCRIPTION OF MATERIALS USED TYPE OF EPDXY Rl SIMPSON SET22 ICBO ER#5279 ❑ - HILTI HY-150 ❑ -OTHER QTHREADED ROD ❑ 1/2" 0 5/8" ❑ 3/4" ❑ 7/8" ❑ 1" El OTHER TYPE OF MATERIAL ❑ REBAR ❑ #3 ❑ #4 ❑ #5 ❑ #6 ❑ #7 ❑OTHER LOCATION OF EPDXY WORK INSPECTED AT G- ASS W 0 1 I / PJtJ A h AlF N0) 5/A f, II -I Ii ftcA.6 1,-Jl�l� �3FA-8E4wrdT Ilr jr--, wra-r 3/4 i)D.I -t-J f2 `DR TcR TG E�oXL.I I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS 8 APPLICABLE BUILDING LAWS. CC: INSPECTORS SIGNATURE INSPECTORS CERTIFICATION AGENCY AND NUMBER j"^�-.......,--�-• ,-.-..--,-.-�'.....�.,,,,_-y„�,.',.t.,.•,,.,u-.-,,,,,.1%'��,�.,•.•�„l-�-i."�...tii.,,,•,y��...��Jt'y-•.%--w�--W,.�`�..t•.C.v::3r•.'�'''�---�---�++.........,r„�'^^r^ti�•.-•..-'. 1 a TANDY'S INSPECTION SERVICES, INC. _ PO BOX 13766 - PALM DESERT, CA 92255-3766 r OFFICE/FAX - 951 .769.9717 PAGER -760.776.3339 SPECIAL INSPECTION EPDXY REPORT TYPE OF INSPECTION PERFORMED EPDXY PERMIT NUMBER Q (o — 2-69-7 TYPE OF STRUCTURE, DATE .2 7 — 0-7 RESIDENTIALc _COMMu RRCIKL PHYSICAL ADDRESS (INCLUDE STWETNAW AND aryl - 520 L i A 5 i 11 rel G- t o to 5'r- JOB NAME QNCLUDE LOT NUMBER/ NAME OF COUNTRY CLUB/ BUSINESS PARK I CORPORATE CENTER ... EMLl __) n 5� � N G --r v ►J � A Q k r.., - A C A PfiD 6 .LA ARCHITECT i<KC. Akco accTS ENGINEER KED 0 t -,a Mora n>JI AS5000ICSN GENERAL CONTRACTOR L -J L (jL.,_-r 1 C-R- SUB CONTRACTOR DESCRIPTION OF MATERIALS USED TYPE OF EPDXY 0 SIMPSON SET22 I[C'B�O ER#5279 ❑ - HILTTII HY-150 ❑ -OTHER P -CS O d THREADED ROD ❑ 1/2" 0, 5/8" ❑ 3/4" 0 7/8" ❑ 1" EI OTHER TYPE OF MATERIAL ❑ REBAR ❑ #3 ❑ #4 ❑ #5 ❑ #6 ❑ #7 ❑ OTHER LOCATION OF EPDXY WORK INSPECTED UI SC Rv�l) 1r.15TAll 6F epoxy nit THWAI) -nCtz T)CLTh A\_ h l►,Ll- - 12- u- C /J .s G-{)- t O l.. C' E A ""D ( i '/R H D IN (,j I T10 Omc^rr I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS 8 APPLICABLE BUILDING LAWS. a CC: 1 r, 11� INSPECTORS SIGNATURE 5 2�167�55 -~ Ug INSPECTORS CERTIFICATION AGENCY AND NUMBER ' TITLE 24 REPORT Title 24 Report for: ;4 Washington Park - Pad 6 Shell Package 46-520 Washington Street La Quinta, CA 92253 Project Designer: KKE Architects, Inc' 4 Executive Circle Suite 190 Irvine, CA 92614 Y (949) 222-1233 Report Prepared By: SIA GARESTANI,.P.E. •� SPEC Engineering 6800 Owensmouth Ave. #140 Woodland Hills, CA 91303 (818) 592-6643 h Job Number: CITY OF LA QUANTA BUILDING &SAFETY DEPT. -05-068 APPROVED OR CONSTRUCTION JUL:, i 7 2006 - Date: oA L co BYIL 8y 6/30/2006 Ow'7-47 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft,'LLC - www.energysoft.com. EnergyPro 4.1 by EnergySoft Job Number: 05-068 User Number: 3358 r TABLE OF CONTENTS Cover Page F 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form ENV -MM Envelope Mandatory Measures 15 Form MECH-MM Mechanical Mandatory Measures 16 HVAC System Heating and Cooling Loads Summary' 18 Room Load Summary 23 Room Heating Peak Loads 28 Room Cooling Peak Loads 33 Room Cooling Coil Loads 39 EnergyPro 4.1 by EnergySoft Job Number: 05-068 User Number: 3358 07506/2006 14:44 949-222-0771 HFTA r Jul 06 2006 2!:31PM SPEC TEK GROUP 8185926639 FP'L-rirZRMANCECr:RTIF'ICAT—E---O-FCOMPLIANCIE Part1 cf 3 PAGE 02/02 PERF.1 PLANSMTO OF *0"6 8,003 84.F 1$ IUILDING TYPE Z1 NONRI118102RIU]. ❑ NIAN 14189 RESIDENTIAL ❑ HOTEI,lNlp DL QUEST MOM MASK OF CONOTRUCTION ® NeW CONSTRUO"ON ❑ AnrnnoN ❑ 6)tlsTlblO+ADD1TlOwALTSRATION Cer4flrals of Cornpllsru$ list$ 04 building tWrturn and psrtbrmalrlce speclfloetiaiae nsedsd m mply with Tit$ K Pane I end s of drt. omis Code of rtrayulallww This eeftlfftto ■ppifma only to a Building using ft podormMnaa . Pllance approach. dorturtrsntatlon pnpsrw hereby weyoss ghat the ddaumeftdon b acerous ead top, UMENTATION AUTHOR 0 ALIW T I Principal Designer hereby cortifyo that the proposed bullcurTa ted In this est OfGaiti lallm dob RL61!� istanl with the other compliance forme and worlrsh�to, ed cations, and wNh any Other a2lailftwa submitted wRh thin Iii applkatlon. The proposed bulldInrtgg as designed meats th eW ell'Woncy requiroments oonialnod In sections 110,118, Igh 118, and 140,.142,143 or 149 ofTkle 24, Pons, % ❑ ❑ 1.1 hereby affirm that I arrl ellglble und<the provisions of Divisian 3 of the Buelness end PmfasWons Code to sign this document as the person responsible for its preparntioni and that I am licensed In the State of California as a civil engineer, meahanlcel engineer, or I em a licensed amhlteat. ❑ ❑ ❑ 2.1 affirm that I am rallgible Undor the provisions of DNlslon 3 of the Buslnrtss and Professions Code Saotlort 5537.2 or 0737.3 to sign this document as the parson responsible for ltrl preperatlori; and that I am a licensed 00*8etar performing this work. ❑ ❑ ❑ 3.1 affirm that I am eligible under Division 3 of the Business and Pmfowlans Code to sign this d=rnent because It pertains to a elruchlre au type of vvrA dseaibed so exempt pursuant to Sulalne4s and Professions Code Sections WV, 5538, and 8797.1. (Phase acceons of the Business and Professions Code are printed in NII In the Nonresidantial Manual.) Indicate location on plans cf Note Bkxdtfor Mandatory Meaaures ENV -1 Indicate; location on plans of Nots Black for Mandatory Measurm Required Fortis fCIPAL LrONTINO DESIGNER. NAME I 61AUAr,oe Iri$ic to location on plane of Note Bleak for Mandwtory Measures MECHANICAL 1315*10NER . NAWK I by EMMYSon Uwir Compliance Not in The K PERFORMANCE CERTIFICATE OF COMPLIANCE Part2 of 3 PER PROJECT NAME s DATE Washington Park - Pad 6 Shell Package 6/30/2006 ANNUAL TDV ENERGY USE SUMMARY kBtu/s ft- r Standard , . Proposed Compliance ENERGY COMPONENT Design { ..Design Glazing 'Margin Space Heating' .Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process TOTALS: 1.50 0.87. a x0.63 465.92 470.61 •-4.69 53.73 57.48 -3.75 0.00 0.00 0.00 0.00 0.00 0.00 170.01 161.16 8.85 108.32 108.32 x•0.00 63.92 63.92 0.00 161.73 161.73 0.00 102513 102410 104 - It StanGa`rti �`'` � Proposed Glazing Area Glazing Ratio Front Elevation s) 1,307 sqft. 498 sqft. Intloor faro � - xr 3 "•• y . M -+ri Left Elevation (W) a sqft. t 222 sqft. 31.3% Rear Elevation (N) F � t sqft. 56 sqft. 4.3% t ° KW Right Elevation (E) Total Roof , 709 4,032 5,083 sqft. sqft. sqft, : 280 1,056 E= u 7", r P { 4.f` hRBaaRhCla,f£ 3 .x ` �, J k" r - . F, E0 30 X60 90 1201501802102402703003303 3804204501. Percent better than Standard: 0.1% ( 0.1%excluding process) BUILDING COMPLIES GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones S 180 deg z.. 5 ` 5 Conditioned Floor Area 5,083 sqft. Unconditioned Floor Area 0 sqft. Conditioned, Footprint Area 0 sqft., Fuel Type M Natural Gas Orientation Gross Area Glazing Area Glazing Ratio Front Elevation s) 1,307 sqft. 498 sqft. 38.1% Left Elevation (W) 709 sqft. t 222 sqft. 31.3% Rear Elevation (N) 1,307 sqft. 56 sqft. 4.3% Right Elevation (E) Total Roof , 709 4,032 5,083 sqft. sqft. sqft, : 280 1,056 E= sgft. sgft. sqft. 39.5% 26.2% 0.0% Standard Proposed , Lighting Power Density 1.34 W/sqft. 1.341 W/sqft. Prescriptive Env. Heat Loss 1,059 Btu/h 1,100 scum Prescriptive Env. Heat Gain 125,020 Btufh-F 153,430 Btu/h-F . Remarks: 4 '. Run Initiation Time: 06/30/06 15:08:38 Run Code: 1151705318 EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 ageA of 44 PERFORMANCE CERTIFICATE,: OF COMPLIANCE Part3 of 3 PERF -1 . PROJECT NAME Washington Park - Pad 6 Shell P • DATE e 6/30/2006 The local enforcement agency should pay special attention to the items specified In this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System "CARRIER 50HJ0005" is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. The HVAC System "CARRIER 50HJ0006" is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. The HVAC System "CARRIER 50HJQ008" includes Demand Control Ventilation per Standards Section 121. The HVAC System "CARRIER 50JX060" is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. The Zone "Suite A" has a North/East/South Display Perimeter Credit of 26 ft. .. The Zone "Suite B" has a North/East/South Display Perimeter Credit of 25 ft. The Zone "Suite C' has a North/East/South Display Perimeter Credit of 18 ft. . The Zone "Suite C' has a North/East/South Display Perimeter Creddof 30 A. r The Zone "Suite C' has a North/East/South Display Perimeter Credit of 92 ft. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant Authorized Signature or Stam Run Initiation Time: 06/30/06 15:08:38 Run Code: 1151705318 EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Page:5 of 44 CERTIFICATE OF COMPLIANCE ENV -1-C PROJECT NAME DATE Washington Park 'Pad 6 Shell Package - 6/30/2006 OPAQUE SURFACES # Surface Type, Area U -Fac. Insulation Cay. Cont. Act. Am. _ Tilt Cond: Status Joint Appendix IV Reference Location / Comments 1 Roof 1,496 0.036 R-30 R-0.0 0 0 New 02-A9 Suite A 2 Wall 288 0.074 R-19 R-0.0 180 90 New 09-A5 Suite A 3 Wall .487 0.074 R-19 R-0.0 270 90' New 09-A5 Suite 4 Wall 334 0.074 R-19 R-0.0 - 0 90 1 New 09-A5 Suite A 5 Roof 1,362 0.036 R-30 R-0.0 0. 0 New ` 02=A9 Suite B 6 Wall 134 0.074 R-19 R-0.0 180, 90 New 09-A5 Suite B 7 Wall 332 0.074 R-19 R-0.0 0 90 New 09-A5 Suite B 8 Roof 1,015 0.036 R-30 R-0.0 0 0 New = 02-A9 Suite C 9 Wall 387 0.074 R-19 R-0.0 180 90 New 09-A5 Suite C 10 Roof. 540 0.036 R-30 R-0.0 0 0 New 02-A9 Suite C 11 lWall 429 0.074 R-19 R-0.0 90 '90 New 09-A5 ISuite C 12 Roof 670 0.036 R-30 R-0.0 0 0 New 02-A9 Suite C 13 Wall 585 0.074 R-19 R-0.0 0 90 ' New 09-A5 Suite C Suite B 13 jWndow Front S 36 0.660 116 -Al 0.73 116-B 180 New I Double Clear Default NM Suite B existing, Altered, Removed) FENESTRATION SURFACES FMore than or equal to 10,000 sq.fL of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from Standards Table 116 -AA and B. Certificate shall he filed in the centmetoes nreiact offlca dudna ennsttuotion and in the hirildinn manners nffim atter nnnstruction # Type Area U -Fac' 1 SHGC' Act. Am. Cond. Stat. Glazing Type Location/ Comments 1 Window Front S 24 0.660 116-A 0.73 116-B 180 New Double Clear Default NM Suite A 2 Window Front S 54 0.660 116-A 0.73 116-B 180 New - Double Clear Default(NM) Suite A 3 Window Front S 24 0.660 116-A 0.73 116-B 180 New , Double Clear Default(NM) Suite A 4 Window Left W 56 0.660 116-A 0.73 116-B 270 New Double Clear Default NM Suite A 5 Window Left 2.0" 56 0.660 116-A 0.73 116-B 270 New Double Clear Default(NM) Suite A 6 jWndow Left 0.76 54 0.660 116 -Al 0.73 116 -BI 270 New ., Double Clear Default(NM) Suite A 7 Window Left 11.0 56 0.6601116-A 0.73 116-B 270 New Double Clear Default(NM) Suite A �. 8 Window Rear N 56 0.6601116-A 0.73 116-8 0 New Double Clear Default(NM) Suite A 9 Window Front S 36 0.6601116-A 0.73 116-B 180 New Double Clear Default(NM) Suite B 10 Window Front (S) 36 0.660 116-A 0.73 116-B 180 New Double Clear Default(NM) Suite B 11 Window Front S 54 0.660 116-A 0.73 116-8 180 New Double Clear Default(NM) Suite B 12 Window Front (S)! 36 0.660 116-A 0.73 116-B 180 New Double Clear Default(NM) Suite B 13 jWndow Front S 36 0.660 116 -Al 0.73 116-B 180 New I Double Clear Default NM Suite B 1 U -tactor Type: 116A Default Table tram Standards, Table NI -1 Default Table from the AGM Manual Appendix, NFRC Labeled value. 2 SHGC Type: 1168 Default Table from Standards, COG Center of Glass, NFRC Labeled Value . , I - EXTERIOR SHADING s ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 1 None 0.76 12.0 2.0 2.0 0.1 2.0 2.0 2 None 0.76 9.0 6.0 2.0 0.1 2.0 2.0 - 3 None 0.76 12.0 •2.0 .2.0 0.1 2.0 2.0 ' 4 None 0.76 7.0 8.0 2.0 0.1 2.0 .1 : 2.0 5 None 0.76 7.0 8.0- 2.0 ,. 0.1 2.0 2.0 ' 6 None 0.76 9.0 6.0 " 2.0 0.1 2.0 2.0 ° 7 None 0.76 7.0 8.0 2.0 0.1 2.0" 2.0 = 8 None 0.76 7.0 8.0 2.0 ` 0.1 2.0. 2.0 9 None 0.76 12.0 3.0 11.0 0.1 11.0 11.0 10 None 0.76 12.0 3.0 , 11:0 0.1 . 11.0 11.0 11 None 0.76 9.0 6.0 11.0 ' 0.1 11.0 11.0 12 None 0.76 12.0 3.0 11.0 0.1, 11.0 11.0 13 INone 0.76 1 12.0.3.0 11.0 0.1 11.0 11.0 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES ' The proposed building contains an enclosed space with floor area greater than 26,000 sq.R, a ceiling height greater than 1S feet and a LPD for general lighting of at least 0.5 W/sq.ft. If this box Is checked, ENV4-C must be filled out when submitting under the Prescriptive Compliance Approach. Run Initiation Time: 06/30/06 15:08:38 . _ Run Code: 1151705318 EnergyPro 4.1 by EnergySoft - User Number: 3358 Job Number: 05-068 Page:6 of 44 l t CERTIFICATE OF COMPLIANCE ENVA -C PROJECT NAME DATE Washington Park - Pad 6 Shell Package 6/30/2006 OPAQUE SURFACES 7771 # I SurfaceI I Insulation Act. I Cond: Joint Appendix Tvoe Area U -Fac. Cay. Cont. Azrn Tilt Status I IV Reference I Location/ Comments N. E, A, R (New, Existing, Altered, C\IC0Tr2AQ11 More than or F-Iequal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default Ll -factors from Standards Table 118-A and B. r ArtificAn shall hp filed in the mntmf!tnes nmiprl nffirn dirtinn rnnstnirJinn and in tha hijilrlinn mamnpfs nffim aepr mnstnuYinn # lTvpe Area U -Fac' SHGC2 Act. Azm. Cond. Stat. Glazing Type Location/ Comments 14 Window Front S 36 0.660 116-A 0.73 116-8 180 New Double Clear Default NM Suite C 15 Window Front S 54 0.660 116-A 0.73 116-8 180 New Double Clear Default(NM) Suite C 16 Window Front (S) 36 0.660 116-A 0.73 116-8 180 New Double Clear Default(NM) Suite C 17 Window Front S 36 0.660 116-A 0.73 116-131 180 New Double Clear Default NM Suite C 18 Window Front S 36 0.660 116-A 0.73 116-B 180 New Double Clear Default NM Suite C 19 Window Right E 56 0.660 116-A 0.73 116-8 90 New Double Clear Default(NM) Suite C 20 jWndow Right E 56 0.660 116-A 0.73 116-8 90 New Double Clear Default NM Suite C 21 Window Right E 56 0.660 116-A 0.73 116-B 90 New Double Clear Default NM Suite C 22 Window Right E 56 0.660 116-A 0.73 116-8 90 New Double Clear Default NM Suite C 23 Window Right E 56 0.660 116-A 0.73 116-B 90 New I Double Clear Default NM Suite C 1 LI -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2 SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 14 None 0.76 12.0 3.0 11.0 0.1 11.0 11.0 15 None 0.76 9.0 6.0 11.0 0.1 11.0 11.0 16 None 0.76 12.0 3.0 11.0 0.1 11.0 11.0 17 None 0.76 12.0 3.0 11.0 0.1 11.0 11.0 18 None 0.76 12.0 3.0 11.0 0.1 11.0 11.0 19 None 0.76 20 None 0.76 21 None 0.76 22 None 0.76 23 None 0.76 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building contains an enclosed space with floor area greater than 25,000 sq.ft, a ceiling height greater than 15 feet and a LPD for general lighting of at least 0.5 W/sq.fL If this box Is checked, ENV4-C must be filled out when submitting under the Prescriptive Compliance Approach. 02- Ti- AC/211111na 4C-flQ-40 0- f^ -A-- 44947nC240 EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Pace:7 of 44 1 CERTIFICATE OF COMPLIANCE MECH-1-C PROJECT NAME DATE Washington Park - Pad 6 Shell Package 6/30/2006 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates, and operatinq and maintenance information meet the requirements of Section 10-103(b) and Title 24 Part 6. STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Rehofit ❑ MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do require construction inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required If the unit serves 5, 000 R2 of space or less and 25% or more of the ducts are in noncondrtioned or semiconditioned space like an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VA fan volume controls installed on new or existing systems must be tested ❑ MECH-8-A: -Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btu/hr. -Water-loop Heat Pump Controls Applies to all new watedoop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable flow chilled, hydronic heat pump or condenser water systems where the pumps motors are greater than 5 hp. Equipment requiring acceptance testing EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Page:8 of 44 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE Washington Park - Pad 6 Shell Package 6/30/2006 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance AIR SYSTEMS Central or Single Zone RTU -1 RTU -2 RTU -3 1 1 1 1 Reference on Plans or Specification 1 112(a) 7.60 HSPF 7.60 HSPF 3.30 COP 112(a) 11.9 SEER / 10.9 EER 11.9 SEER / 10.9 EER 10.3 EER 112(b) Yes Yes Yes 112(c), 115(a),n/a 54,901 btuh n/a n/a 121(b) No No No 121 b 510 cfm 730 cfm 544 cfm 121 c No No No 121 c No No Yes 121(c), 122(e) Procirammable Switch Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required 122 Auto Auto Auto 122 n/a n/a n/a 123 124 R-4.2 R-4.2 R-4.2 144 a & b n/a n/a n/a 144 a & b 37,474 btuh 37,474 btuh 53,089 btuh 144 a & b n/a n/a n/a 144 a & b 54,901 btuh 58,122 btuh 74,284 btuh 144 c Constant Volume Constant Volume Constant Volume 144 (c) 144 c Yes Yes Yes 144 d No No No 144 a No Economizer No Economizer Fixed Tem (Integrated) 144 Constant Temp Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp Constant Temp 144 (k) No No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% dud in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method dud sealing requirements. 1 EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Page:9 of 44 1 i IR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE Washin ton Park ' Pad 6 Shell Package 6/30/2006 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) ' Number of Systems AIR SYSTEMS, Central or Single Zone RTU4 - RTU -5 112(a) '. 12.0 SEER / 10.6 EER 12.0 SEER / 10.0 EER T-24 r MANDATORY MEASURES ' Section Reference on Plans or Specification 1 Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation 1,12(a) 8.00 HSPF . 7.00 HSPF 112(a) '. 12.0 SEER / 10.6 EER 12.0 SEER / 10.0 EER 112(b) Yes r Yes 112(c), 115(a) Na '' n/a 121(b), No No w 121 b V 289 cfm • 67 cfm 121 c No No .121 (c). No No 121(c), 122(a) Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Required 122 Auto Auto 122 n/a n/a 123 124 R-4.2 R-4.2-, PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 . Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance3 144 a & b n/a y. n/a 144 a & b 28,730 btuh 35,601 btuh 144 a & b . n/a " n/a 144 a & b 31,068 btuh •a 42,031 btuh 144 c Constant Volume Constant Volume 144 (c) - 144 c Yes Yes 144 d- ' No No 144 e : = No Economizer _ No Economizer 144 t Constant Temp Constant Tem 144(f) Constant Temp Constant Temp 144 (k) • . No ti No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. j�4 3: Enter Yes if System is: Constant Volume, Sin le Zone; Serves < 5,000 s Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, Y 9 qft; P 9 reg P• P" see PERF -1 for performance method duct sealing requirements. - EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Page: 10 of 44 NATER SIDE SYSTEM REQUIREMENTS Part 2 of 2 MECH-2-C PROJECT NAME DATE Washington Park - Pad 6 Shell Package - 6/30/2006 YSTEM FEATURES 2 WATER SIDE SYSTEMS: Chillers, Towers, Boilers, Hydronic Loops ITEM OR SYSTEM TAG(S) s " Number of Systems ° T-24 w MANDATORY MEASURES Section ' - - "' Reference on Plans or Specification) Equipment Efficiency Pipe Insulation 123 PRESCRIPTIVE MEASURES Calculated Capacity 144 (a & b) Proposed Capacity 144 (a & b)' Tower Fan Controls 144 h Tower Flow Controls 144 h Variable Flow System Design 144 •) Chiller and Boiler Isolation 144 CHW and HHW Reset Controls 144 0) WLHP Isolation Valves 144 6) VSD on CHW, CW & WLHP Pumps > 5 144 . HP ^' DP Sensor Location 144 1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A'• in the column. 2: Water side systems include wet side system using other liquids such as glycol or brine: + r Service Hot Water, Pool Heating ITEM OR SYSTEM TAG(S) DHW Heater Number of Systems 2 MANDATORY MEASURES Reference on Plans or Specification' Water Heater Certification 113 (a) Water Heater Efficiency 113 (b) Service Water Heating Installation 113 (c)- c)-Pool Pooland Spa Efficiency and Control 114 (a) , Pool and Spa Installation r Pool Heater - No Pilot Light 115( C) Spa Heater - No Pilot Light - 115 d 1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A'• in the column. 2: Water side systems include wet side system using other liquids such as glycol or brine: + r Service Hot Water, Pool Heating ITEM OR SYSTEM TAG(S) DHW Heater Number of Systems 2 MANDATORY MEASURES Reference on Plans or Specification' Water Heater Certification 113 (a) Water Heater Efficiency 113 (b) Service Water Heating Installation 113 (c)- c)-Pool Pooland Spa Efficiency and Control 114 (a) , Pool and Spa Installation 114 (b) Pool Heater - No Pilot Light 115( C) Spa Heater - No Pilot Light - 115 d CHRONOMITE S-30 LP 98% ' n/a n/a . n/a ' n/a 1: For each water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A'• ins the column. MECHANICAL VENTILATION MECH-3-C PROJECT NAME DATE Washington Park - Pad 6 Shell Package 6/30/2006 PRESCRIPTIVE REHEAT LIMITATION (Section 144(d) MECHANICAL VENTILATION Section 121 W21 AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H I J K L M N ZONE/SYSTEM 0 D� T6.a Dt = CO) C man m�3 •n °o Cr3 W�� xDn 00 -n — °' 3 c �3 v0 , `° o, m n c�3 ' tT 3 m�� x2n nT 3 m �m0 -xG O �'" D <0 (gym 3�'(Cc c D' No 5' A®C Eco Q) v y. -n 3W a� A ;Kn °c �(ex O T? O `n c3 ' •' -t m � D Suite A 1,496 0.22 329 34.0 15.0 510 510 510 RTU -1 Total 510 510 Suite B 1,362 0.38 518 48.6 15.0 730 730 730 RTU -2 Total 730 730 Suite C 1,015 0.381 386 36.2 15.0 544 544 544 RTU -3 Total 544 544 Suite C 54C 0.38 205 19.3 15.0 289 289 289 RTU -4 Total 289 289 Suite C 67C 0.151 101 4.5 15.0 67 101 67 34 RTU -5 Total 101 67 C Minimum ventilationt eSection Table 121 -A E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load foregress purposes fors aces without fixed seating. H Required Ventilation Air REO'D V.A. is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS column D or G). I Must be greater than orequal to H or use Transfer Air column N to make up the difference. J Design fan supply dm (Fan CFM) x 30%; or K Condition area ft. x 04 dmtft. s .0 or L Maximum of Columns H, J, K, or 300 dm M This must be less than or equal to Column L and greater that or equal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column H) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column H) and the Design Minimum Air (column M), column H - M. Energ Pro 4.1 by Energ Soft User Number: 3358 Job Number. 05-068 Page: 12 of 44 MECHANICAL EQUIPMENT. DETAILS Part 1 of 2 MECH-5-C PROJECT NAME Washington Park - Pad 6 Shell Package DATE 6/30/2006 CHILLER AND TOWER SUMMARY System Type Distribution Type Efficiency Tons PUMPS Condition Status Ext. R -Val. Equipment Name Equipment Type Qty. Tot. Qty GPM I BHP Motor Eff. Drive Eff. Pump Control n/a MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water P mp Hot Water Piping Longth ft Control # HP Type In Plenum Outside Buried Add 1/2" Insulation DHW / BOILER SUMMARY Energy Factor or RE Standby Loss or Pilot TANK INSUL. System Name System Type Distribution Type Qty Rated Input Vol. (Gals.) Condition Status Ext. R -Val. CHRONOMITE S-30 LP Instant Elec No Pipe Insulation 2 9,429 0 New 0.98 n/a n/a MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water P mp Hot Water Piping Longth ft Control # HP Type In Plenum Outside Buried Add 1/2" Insulation CENTRAL SYSTEM RATINGS HEATING COOLING System Name system Type Output Aux. kW Eff. outout Efficiency Condition Status Economizer Type CARRIER 50HJQ006 Packaged DX 2 60,000 0.0 7.60 HSPF 62,200 11.9 SEER / 10.9 EER New No Economizer CARRIER 50HJQ008 Packaged DX 1 85,000 0.0, 3.30 COP 91,30010.3 EER New Fixed Temp (Integrate CARRIER 50HJ0005 Packaged DX 11 46,000 0.0 8.00 HSPF 47,400 12.0 SEER / 10.6 EER New No Economizer CARRIER 50JX060 Packaged DX 1 57,000 0.0 7.00 HSPF 57,500 12.0 SEER / 10.0 EER New No Economizer CENTRAL SYSTEM FAN SUMMARY SUPPLVFAN RETURN FAN System Name Fan Type Motor Location CFM BHP Motor Eff. Drive Eff. CFM I BHP Motor Eff. Drive Eff. CARRIER 50HJ0006 Constant Volume Draw -Through 2,000 0.40 66.0% 97.0% none CARRIER 50HJ0008 Constant Volume Draw -Through 3,000 0.40 66.0% 97.0% none CARRIER 50HJQ005 Constant Volume Draw -Through 1,600 0.30 64.0% 97.0% none CARRIER 50JX060 Constant Volume Draw -Through 2,000 0.50 76.0% 97.0% none Run Initiation Time: 06/30/06 15:08:38 Run Code: 1151705318 Energypro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Page: 13 of 44 1 . MECHANICAL EQUIPMENT DETAILS Part 2 of 2 MECH-5-C PROJECT NAME DATE Washinaton Park - Pad 6 Shell Packaae 6/30/2006 Min. CFM FAN SUMMARY TERMINAL FAN BASEBOARD Motor Drive CFM BHP Eff. Eff. Type Output EXHAUSTFAN EXHAUSTF N Room Name Q ty. CFM BHP Motor Eff. Drive Eff. Room Name Q CFM BHP Motor Eff. Drive Eff. Port Of Sub 1.0 500 0.25 64.0°/ 97.0% ' Run Initiation Time: 06/30/06 15:08:38 Run Code: 1151705318 EnergyPro 4.1, by EnergySoft User Number: 3358 Job Number: 05-068 Page]4 of 44 ENVELOPE MANDATORY MEASURES ENV - PROJECT NAME PATE Washin ton Park - Pad 6 Shell Package 6/30/2006. DESCRIPTION Desig ner Enforcement ❑X §118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. X § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. ❑ ' § 117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. FXJ§ 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). 0 § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for 0 -value according to NFRC procedures. R §118(e) Demising Walls In Nonresidential Buildings: t The opaque portions of framed demising walls In nonresidential buildings shall have Insulation with an installed R -value of no less than R-11 between framing members. EnergyPro By EnergySoft User Number: User Job Number: 05-068 Page: 15 of 44 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME DATE Washington Park - Pad 6 Shell Package 6/30/2006 DESCRIPTION Desi mer Enforcement Equipment and Systems Efficiencies X❑ §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. X] § 115(a) Fan type central furnaces shall not have a pilot light. X] § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: X] § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or XJ § 122(e)1 B An occupancy sensor to control the operating period of the system; or § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. X❑ § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control Heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro By EnergySoft User Number: User Job Number: 05-068 Page: 16 of 44 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAME DATE Washington Park - Pad 6 Shell Package . 6/30/2006 Description Designer Enforcement Ventilation ❑X § 121(e) controls shall be provided to allow outside air dampers or devices to be operated at f the ventilation rates as specified on these plans. , 0 § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. 0 § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers In all openings to the outside, except for combustion air openings. X❑ § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or X❑ § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the Installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or ❑ § 121(04 Another method approved by the Commission. Service Water Heating Systems XJ § 113(b)2 If a circulating hot water system is installed; it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. , § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. « X❑ § 113(b)3C Lavatories In restrooms of public_ facilities'shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. , Proximity sensor actuated control valves, and outlet_ devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. ` Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). - EnergyPro By EnergySoft User Number: User Job Number: 05-068 Page: 17 of 44 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Washington Park - Pad 6 Shell Package 6/30/2006 SYSTEM NAME FLOOR AREA RTU -1 1,496 Number of Systems 1 Heating System Output per System 60,000 Total Output (Btuh) 60,000 Output (Btuh/sgft) 40.1 Cooling System Output per System 62,200 Total Output (Btuh) 62,200 Total Output (Tons) 5.2 Total Output (Btuh/sgft) 41.6 Total Output (sgtVTon) 288.6 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.34 Airflow (cfm/Ton) 385.9 Outside Air (%) 25.5 Outside Air (cfm/sgft) 0.34 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 11COILHTG.PEAK CFM I Sensiblel Latent I I CFM I Sensible 3,234 65,395 6,460 457 17,016 0 3,270 85 0 0 510 19,23 9,323 510 23,664 0 0 3,2701 851 91,2141 15:77831 42 38 HVAC EQUIPMENT SELECTION CARRIER 50HJ0006 54,901 2,237 37,474 Total Adjusted System Output 90 2,237 37,a74 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug a pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 58.5 of 105.0 of 105.0 of .01 Supply Air Ducts Outside Air 0 510 cfm Heating Coil Supply Fan 104.6 of 2000 cfm ROOMS 69.6 of 70.0 of Return Air Ducts I TOOLING SYSTEM 11.0 / 77.6 of Outside Air 510 cfm 75.5/62.4 of 84.6 / 66.7 of 55.0 / 53.6 of 55.0 / 53.6 of Z . Supply Air Ducts Cooling Coil Supply Fan 56.5 / 54.3 °F 2000 cfm 50.6% R.H. ROOMS 74.0 / 61.8 of I h Return Air Ducts `S EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Page: 18 of 44 r HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Washington Park - Pad 6 Shell Package 6/30/2006 SYSTEM NAME FLOOR AREA RTU -2 1,362__ Number of Systems 1 Heating System Output per System 60,000 Total Output (Btuh) 60,000 Output (Btuh/sgft) 44.1 Cooling System Output per System 62,200 Total Output (Btuh) 62,200 Total Output (Tons) 5.2 Total Output (Btuh/sqft) 45.7 Total Output (sgft/Ton) 262.8 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.47 Airflow (cfmrron) 385.9 Outside Air (%) 36.5 Outside Air (cfm/sgft) 0.54 Note: values above given at ARI conditions 26.0 of Outside Air 730 cfm 69.8 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 2,032 41,088 9,242 253 9,425 0 2,054 47 0 0 730 28,754 12,51 730 33,994 0 0 2,054 471 73,968F 2177531 44 36 CARRIER 50HJQ006 58,122 563 37,474 Total Adjusted System Output 58,122 563 37,474 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am 53.8 of ® 105.0 of Heating Coil 105.0 of Supply Air Ducts Supply Fan 104.8 of 2000 cfm ROOMS 70.0 of Return Air Ducts I ICOOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peakl I 12.0 / 77.9 of Outside Air 730 cfm 75.0/62.5 of 88.5 / 68.6 of ® 55.0 / 53.5 of Cooling Coil Supply Fan 2000 cfm 55.0 / 53.5 of -� Supply Air Ducts 56.0/53 . 9 of 51.9% R.H. ROOMS 74.0 / 62.2 of h Return Air Ducts `i I EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Pane: 19 of 44 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Washington Park - Pad 6 Shell Package 6/30/2006 SYSTEM NAME FLOOR AREA :::] RTU -3 1.,.0 1 5 [ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 85,000 Total Output (Btuh) 85,000 Output (Btuh/sgft) 83.7 Cooling System Output per System 91,300 Total Output (Btuh) 91,300 Total Output (Tons) 7.6 Total Output (Btuh/sgft) 90.0 Total Output (sgft/Ton) 133.4 Air System CFM per System 3,000 Airflow (cfm) 3,000 Airflow (cfm/sgft) 2.96 Airflow (cfm/Ton) 394.3 Outside Air (%) 18.1 Outside Air (cfm/sgft) 0.54 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent I CFM I Sensible 1,650 33,353 6,888 231 8,618 0 1,668 43 0 0 544 21,675 10,273 544 25,383 0 0 1,668 431 58,479J6 17 16 34 863 HVAC EQUIPMENT SELECTION CARRIER 50HJQ008 74,284 7,051 53,089 Total Adjusted System Output7x,284 7,051 53,089 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 61.9 OF 105.0 OF 105.0 OF 0 Outside Air Supply Air Ducts 544 cfm Heating Coil Supply Fan 104.9 °F 3000 cfm ROOMS 70.0 OF 69.9 OF K Return Air Ducts '4 DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0/77.9°F 81.3/65.2°F 55.0/53.7°F 55.0/53.7 OF O Supply Air Ducts Outside Air 544 cfm Cooling Coil Supply Fan 55.5 / 54.0 OF 3000 cfm 49.9% R.H. ROOMS 74.5/61.8 °F 74.0/61.6°F h Return Air Ducts 11 EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Page: 20 of 44 i HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Washington Park - Pad 6 Shell Package 6/30/2006 SYSTEM NAME FLOOR AREA RTU -4 540 Number of Systems 1 Heating System Output per System 46,000 Total Output (Btuh) 46,000 Output (Btuh/sgft) 85.2 Cooling System Output per System 47,400 Total Output (Btuh) 47,400 Total Output (Tons) 4.0 Total Output (Btuh/sgft) 87.8 Total Output (sgft/Ton) 136.7 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sgft) 2.96 Airflow (cfm/Ton) 405.1 Outside Air (%) 18.1 Outside Air (cfm/sgft) 0.54 Note: values above given at ARI conditions 26.0 OF Outside �� 289 cfm 69.7 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK ICOILHTG.PEAK CFM I Sensible Latent CFM I Sensible 3,795 39,340 3,664 LILIE 10,383 0 1,967 519 0 0 289 10,156 1,087 289 13,452 0 0 1,967 519 53,82 4 75 F7724 874 CARRIER 50HJQ005 31,068 14,571 28,730 Total Adjusted System Output 31,068 14,571 28,730 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 1 pm Jan 12 am 61.8°F @78.7°F Heating Coil -Q� Supply Fan 1600 cfm 78.7 OF -� Supply Air Ducts 78.4 OF ROOMS 70.0 OF k Return Air Ducts 4 COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 108.3 / 76.9 OF 81.2 / 68.7 OF 63.0 / 62.0 OF 63.0 / 62.0 OF O Supply Air Ducts Outside Air 289 cfm Cooling Coil Supply Fan 64.3 / 62.4 OF 1600 cfm 67.2% R.H. ROOMS 75.3/66.7°F 74.0/66.3°F k Return Air Ducts `i EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Page:21 of 44 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Washington Park - Pad 6 Shell Package 6/30/2006 SYSTEM NAME FLOOR AREA RTU -5 670 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM Sensible 1,533 30,990 9,996 80 2,966 0 1,550 148 0 0 67 2,658 1,025 67 3,132 0 0 1,550 1 148 36 752 11 020 1 6,3951 HVAC EQUIPMENT SELECTION CARRIER 50JX060 42,031 7,960 35,60 Total Adjusted System Output42,03 7,960 35,60 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 68.5 OF 105.0 OF 105.0 OF Outside Air Q Supply Air Ducts 67 cfm Heating Coil Supply Fan 104.9 OF 2000 cfm ROOMS 70.0 OF 69.9 OF �% Return Air Ducts 'I SYSTEM 112.0/77.9 OF 76.0/63.7 OF 55.0/54.1 OF Outside Air 0' 67 cfm Cooling Coil Supply Fan 2000 cfm 74.7/63.0 OF 55.0 / 54.1 of -� Supply Air Ducts 55.7 / 54.4 OF 54.0% R.H. ROOMS 74.0/62.8 OF h Return Air Ducts `{ EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Page:22 of 44 1 FROOM LOAD SUMMARY PROJECT NAME Washington Park - Pad 6 Shell Package DATE 6/30/2006 SYSTEM NAME RTU -1 FLOOR AREA 1,496 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite A Vanilla Shell 1 3,258 65,874 6,460 3,234 65,395 6,460 457 17,016 PAGE TOTAL 1 3,234 65,395 6,460 457 177016 TOTAL 1 3,234 65,395 6,460 457 17,016 EnergyPro By EnergySoft User Number: User Job Number: 05-068 Page:23 of 44 ROOM LOAD SUMMARY PROJECT NAME Washington Park - Pad 6 Shell Package DATE 6/30/2006 SYSTEM NAME RTU -2 FLOOR AREA 1,362 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite B Port Of Sub 1 2,040 41,255 - 9,242 2,032 41,088 9,242 253 9,425 PAGE TOTAL 1 2,032 41,088 9,242 253 9,425 TOTAL 1 2,032 41,088 9,242 253 9,425 EnergyPro By EnergySoft User Number: User Job Number: 05-068 Page: 24 of 44 ROOM LOAD SUMMARY PROJECT NAME Washington Park - Pad 6 Shell Package DATE 6/30/2006 SYSTEM NAME RTU -3 FLOOR AREA 1,015 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite C Pick up Stix 1 1,715 34,670 6,888 1,650 33,353 6,888 231 8,618 PAGE TOTAL 1 1,650 33,353 6,888 231 8,618 TOTAL 1 1,650 • 33,353 6,888 231 8,618 EnergyPro By EnergySoft User Number: User Job Number: 05-068 Page:25 of 44 ROOM LOAD SUMMARY PROJECT NAME Washington Park - Pad 6 Shell Package DATE 6/30/2006 SYSTEM NAME RTU -4 FLOOR AREA 540 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite C Pick up Stix 1 4,172 43,246 3,664 3,795 39,340 3,664 1,167 10,383 PAGE TOTAL 1 3,795 39,340 3,664 1,167 10,383 TOTAL 1 3,795 39,340 3,664 1,167 10,383 EnergyPro By EnergySoft User Number: User Job Number: 05-068 Page:26 of 44 ROOM LOAD SUMMARY PROJECT NAME Washington Park - Pad 6 Shell Package DATE 6/30/2006 SYSTEM NAME RTU -5 FLOOR AREA 670 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite C Pick up Stix 1 1,535 31,038 9,996 1,533 30,990 9,996 80 2,966 PAGE TOTAL 1 1,533 30,990 9,996 80 2,966 TOTAL 1 1,533 30,990 9,996 80 2,966 EnergyPro By EnergySoft User Number: User Job Number: 05-066 Page:27 of 44 FROOM HEATING PEAK LOADS Project Title Date Washin ton Park - Pad 6 Shell Package 6/30/2006 Room Information Desi n Conditions Room Name Vanilla shell Time of Peak Jan 12 am Floor Area 1,496 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr 1,496.0 X x x X x X X X X x x x x x x x X X x x X x x x X X x x X x X x X x X x X x x 0.0360 X x X X X X X X X X X X x x x X X x X x X X x x X x X x X X x X x x x x X X X 44 = = = = = = = = = = = = = = 2,370 288.0 0.0740 44 938 24.0 0.6600 44 697 54.0 0.6600 44 1,568 24.0 0.6600 44 697 487.0 0.0740 44 1,586 56.0 0.6600 44 1,626 56.0 0.6600 44 1,626 0 0,6600 44 1,568 56.0 0.6600 1.626 334.0 0.0740 44=loss 56.0 0.6600 44 1,626 nems Shown With an asterisk (-) denote Conduction through an interior surface to another room. Page Total: I 17,0161 Infiltration: 1.00 x 1.064 x 1 496 x 13.00 x o.000 / 60] x ® Q "Schedule Air Sensible Area Ceiling Height ACH I&T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 17,016 EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Page:28 of 44. . --7] FOM HEATING PEAK LOADS Project Title Date Washin ton Park - Pad 6 Shell Package 6/30/2006 Room Information Desi n Conditions Room Name Port of sub Time of Peak Jan 12 am Floor Area 1,362 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr Items shown with an asterisk ('rr) denote conduction through an interior surface to another room. Page Total: 9 425 Infiltration: I1 1.001 x 1.064 x 1 362 x 13.00 x 0.000 / 60] x ® = 0 chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,425 EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Page: 29 of 44 1362.0 X x X x x x x x x X x X X x x x X X X X X X X x X x X x x x x x x x X x X X x 0.0360 X x X x X X x X x x x X X X X X x x x x X x X X X X x X x x X x X x X x x X x 44 = = = = = = = = = = = = = = = = = 2,157 134.0 0.0740 44 436 36.0 0.6600 44 1,045 36.0 0.6600 44 1,045 54.0 0.6600 44 1,568 36.0 0.6600 44 1,045 36.0 0.6600 44 1,045 332.0 0.0740 44 1,081 Items shown with an asterisk ('rr) denote conduction through an interior surface to another room. Page Total: 9 425 Infiltration: I1 1.001 x 1.064 x 1 362 x 13.00 x 0.000 / 60] x ® = 0 chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,425 EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Page: 29 of 44 • i t ROOM HEATING PEAK LOADS Project Title Date Washin ton Park - Pad 6 Shell Packa a 6/30/2006 Room Information Desi n Conditions Room Name Pick up Stix Time of Peak Jan 12 am Floor Area 1,015 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr Items shown with an asterisk ('rr) denote conduction through an interior surface to another room. Page Total: 8 618 Infiltration: I1 1.001 x 1.064 x 1 015 x 13.00 x 0.000 / 6] x AT = 0 chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 8,618 EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Page: 30 of 44 1015.0 X X x x X x X x x x x X X X X x x X x X X X X x X x X X X X X X X X x X X x X 0.0360 X X x X X X x X x x x X X x X X X x x X X X X X X X X X X X X X X X x X X x x 44 = = = = = = = = = = = = = = = = 1,608 387.0 0.0740 44 1,260 36.0 0.6600 44 1,045 54.0 0.6600 44 1,568 36.0 0.6600 44 1,045 36.0 0.6600 44 1,045 36.0 0.6600 44 1,045 Items shown with an asterisk ('rr) denote conduction through an interior surface to another room. Page Total: 8 618 Infiltration: I1 1.001 x 1.064 x 1 015 x 13.00 x 0.000 / 6] x AT = 0 chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 8,618 EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Page: 30 of 44 ROOM HEATING PEAK LOADS Project Title Date Washin ton Park - Pad 6 Shell Package 6/30/2006 Room Information Desi n Conditions Room Name Pick up Stix Time of Peak Jan 12 am Floor Area 540 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr Defa Items shown With an astensK (-)) denote conduction through an Interior surface to another room. Page Total: I 10,3831 Infiltration: I1 1.001 x 1.064 x 540 x 13.00 x 0.000 / 60] x 0 = 0 chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 10,383 EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Page:31 of 44 540.0 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 0.0360 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 44 = = = = = = = = = = = = = 855 429.0 0.0740 44 1,397 56.0 0.6600 44 1,626 56.0 0.6600 44 1,626 56.0 0.6600 44 1.626 56.0 0.6600 44 1,626 56.0 0.6600 44 1,626 Items shown With an astensK (-)) denote conduction through an Interior surface to another room. Page Total: I 10,3831 Infiltration: I1 1.001 x 1.064 x 540 x 13.00 x 0.000 / 60] x 0 = 0 chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 10,383 EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 05-068 Page:31 of 44 FROOM HEATING PEAK LOADS Project Title Date Washin ton Park - Pad 6 Shell Package 16/30/2006 Room Information Desi n Conditions Room Name Pick up Stix Time of Peak Jan 12 am Floor Area 670 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr 1 670.0 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0360 x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 44 = = = = 1,061 585.0 0.0740 44 1,905 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 2 966 Infiltration: `11.001 x 1.064 x 670 x 13.00 x 0.000 / 60] x 0 = 0 chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 2,966 EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number. 05-068 Page:32 of 44 ROOM COOLING PEAK LOADS Project Title Washington Park - Pad 6 Shell Package DETD 1 Date I 6/30/2006 ROOM INFORMATION DESIGN CONDITIONS 26.5 Room Name Vanilla Shell Time of Peak Jul 5 pm Floor Area 1,496 Outdoor Dry Bulb Temperature 109 OF Indoor Dry Bulb Temperature 74`F Outdoor Wet Bulb Temperature 77 OF Conduction -30 Roof -19 Wall .19.24.16 Double Clear Default NM Double Clear Default NM Double Clear Default NM -19 Wall .19.24.16 Double Clear Default NM Double Clear Default NM Double Clear Default NM Area 1,496.0 288.0 24.0 54.0 24.0 487.0 56.0 56.0 54.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 0.0360 0.0740 0.6600 0.6600 0.6600 0.0740 0.6600 0.6600 0.6600 X X X X X X X X X DETD 1 = = = = = = = = = 54.3 49.6 26.5 26.5 26.5 84.7 26.5 26.5 26.5 Page Total Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC Weighting X X X X x X X X x X Factor = = = = = = = = (S) 24.0 24 0.813 1.486 U 54.0 24 0.813 1.401 (S) 24.0 24 0.813 1.486 (W) 56.0 215 0.813 0.532 (W) 56.0 215 0.813 0.532 (W) 54.0 219 0.813 0.544 (W) 56.0 215 0.813 0.532 (N) 56.0 43 0.813 0.858 Page Total Btu/hr 2,922 1,057 420 946 420 3.054 981 981 946 11 726 Btu/hr 696 1,475 696 5,198 5,198 5.228 5 198 1 679 1 25 370 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor i hts 1.0c X 1,496 X 1.500 Watts/sqft X 3.41 Btuh/Watt x 1.000 = 7,658 ccu ants 1.0 X 1,496 X 230 Btuh/OCC. 4, sgft/occ. X 1.00 = 7,820 Receptacle 1.0 X 1,496 X 0.000 Watts/sqft x 3.41 Btuh/Watt X 1.00 = 0 rocess r1.0 X 1,496 X 2.000 Watts/sgft X 3.41 Btuh/Watt X 1.00 = 10,212 Infiltration: I 1.00 x 1.064 x 1 496 x 13.00 x 0.00 /601 x -Schedule Air Sensible Area Ceiling Height ACH &T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM65,874 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 x 1 496 X 190 Btuh/OCC. / 44 sgft/OCc. = 6 460 Receptacle 1.00 x x Watts/sgft x Btuh/Watt = rocess 1.00 X 1,496 X 0.000 Watts/sgft X 1 3.413 Btuh/watt = 0 Infiltration: xx 1 496 x x � / 6] x ®_ chedule Air Latent Area Ceiling Height ACH pyy ROOM COOLING PEAK LOADS Project Title Washington Park - Pad 6 Shell Package Date 6/30/2006 ROOM INFORMATION DESIGN CONDITIONS Room Name Vanilla Shell Time of Peak Jul 5 pm Floor Area 1,496 Outdoor Dry Bulb Temperature 109 ,1� Indoor Dry Bulb Temperature 74 'IF Outdoor Wet Bulb Temperature 77 OF Conduction Clear Clear Defa Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 0.0640 0.0740 DETD 1 26.5 = 45.6 = 26.5 = Page Total Weighting Orientation Area SGF SC Factor x x x = x x x = x x x = x x x = x x x = x x x = X x X = X x X = x x x = x x x = Page Total Btu/hr 981 1,127 981 3 088 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor i hts 1.0 x 1,496 X 1.500 Watts/sqft X 3.41 Btuh/Watt X 1.000 = 7,658 ccu ants 1.0 x 1,496 x 230 Btuh/OCC. / 4, sgft/occ. x 1.00 = 7,820 Receptacle 1.0 x 1,496 X 0.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 0 rocess 1.0 x 1,496 x 2.000 Watts/sgft x 3.41 Btuh/Watt x 1.00 = 10,212 Infiltration: I 1.00 x 1.064 x 1 496 x 13.00 x 0.00 /601 x -Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 05,874 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 x 1 496 X 190 Btuh/occ. / 44 sqft/occ. = 6 460 Receptacle 1.00 x x 0.000 Watts/sqft x Btuh/Watt = Process 1.00 X 1,496 x 0.000 Watts/sqft x 3.413 Btuh/Watt = o Infiltration: x aa7 x 1 496 x x � / 6] x Aw _ chedule Air Latent Area Ceiling Height ACH TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6460 EnergyPro By EnergySoft User Number: User 05-068 Page:34 of 44 ROOM COOLING PEAK LOADS Project Title Washington Park - Pad 6 Shell Package Area Date I 6/30/2006 ROOM INFORMATION DESIGN CONDITIONS Sc Room Name Port Of Sub Time of Peak Nov 3 pm Floor Area 1,362 Outdoor Dry Bulb Temperature 87 OF Indoor Dry Bulb Temperature 74 OF Outdoor Wet Bulb Temperature 57 OF Conduction 30 Roof 19 Wall .19.2x6.16 Double Clear Default NM ouble Clear Default NM Double Clear Default NM Double Clear Default NM Double Clear Default NM -19 Wall .19.2x6.16 Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 0.0360 0.0740 DETD 1 21.0 = 73.9 = 6.5 = 6.5 = 6.5 = 6.5 = 6.5 = 9.8 = Page Total Orientation Area X x x X X x X X X X SGF X x X X X X X X X X Sc Weighting X x x x x x X X x x Factor = = = = = (S) 36.0 100 0.813 0.833 (S) 36.0 100 0.813 0.833 (S) 54.0 81 0.813 0.715 (S) 36.0 100 0.813 0.833 (S) 36.0 100 0.813 0.833 Page Total Btu/hr 1,032 732 154 154 231 154 154 241 2 852 Btu/hr 2,448 2,448 2,549 2,448 2,448 12341 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor i hts 1.0 X 1,362 X 1.200 Watts/sqft x 3.41 Btuh/Watt x 1.000 = 5,578 ccu ants 1.0 X 1,362 X 230 Btuh/OCC. / 2 sgft/occ. X 1.00 = 11,188 Receptacle 1.0 X 1,362 X 0.000 Watts/sqft X 3.41 Btuh/Watt x 1.00 = 0 rocess 1.0 x 1,362 x 2.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 9,297 Infiltration: 1.00 x 1.064 x 1 362 x 13.00 x 0.00 / 6] x 38 = F0 chedule Air Sensible Area Ceiling Height ACH &T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 41,255 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 x 1 362 X i9ol Btuh/OCC. / 28 sqft/occ. = 9 242 Receptacle 1.00 x x 0.0001 Watts/sgft x Btuh/Watt = rocess 1.00 x 1,362 x 0.000 Watts/sqft x 3.413 Btuh/Watt = o Infiltration: x 4,77 x � x x � / 6] x ®_ chedule Air Latent Area Ceiling Height ACH pVy ROOM COOLING PEAK LOADS Project Title Washington Park - Pad 6 Shell Package Area Date 6/30/2006 ROOM INFORMATION DESIGN CONDITIONS SC Room Name Pick up Stix Time of Peak Nov 3 pm Floor Area 1,015 Outdoor Dry Bulb Temperature 87 OF Indoor Dry Bulb Temperature 74`F Outdoor Wet Bulb Temperature 57 OF Conduction Roof Clear Area 387 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 0.0360 0.0740 1 0.66001 DETD 1 21.0 = 45.1 = 6.5 = 6.5 = 6.5 = 6.5 = 6.5 = Page Total Orientation Area X X X X X X X X x X SGF X X X X X X X X xX X SC Weighting X x X X X X X X X Factor = = = = = (S) 36.0 100 0.813 0.833 (S) 54.0 81 0.813 0.715 (S) 36.0 100 0.813 0.833 (S) 36.0 100 0.813 0.833 (S) 36.0 100 0.813 0.833 Page Total Btu/hr 769 1,290 154 231 154 154 154 2 907 Btu/hr 2A48 2,549 2,448 2,448 2,448 12 341 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor i hts 1.0 X 1,015 X 1.200 Watts/sqft X 3.41 Btuh/Watt X 1.000 = 4,157 ccu ants 1.0 X 1,015 X 230 Btuh/OCC. / 2l sqft/occ. X 1.00 = 8,338 Receptacle 1.0 X 1,015 X 0.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 0 rocess Ledule .0 x 1,015 x 2.000 Watts/sgft X 3.41 Btuh/Watt x 1.00 = 6,928 Infiltration: 1.00 x 1.064 X 1 015 x 13.00 x o.00 /601 x Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 34,670 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 1,0151 X 1901 Btuh/OCC. / 28 sgft/occ. = 6 888 Receptacle 1.00 x x0.0001 Watts/sqft x Btuh/Watt = process 1.00 x 1,015 x 0.000 Watts/sgft x 3.413 Btuh/Watt = o Infiltration: x 4;77 x � x x � / 6] x 0.00000 = chedule Air Latent Area Ceiling Height ACH pvV TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6 888 EnergyPro By EnergySoft User Number: User 05-068 Page: 36 of 44 ROOK! COOLING PEAK LOADS Project Title Washington Park - Pad 6 Shell Package 0.0360 Date I 6/30/2006 ROOM INFORMATION DESIGN CONDITIONS X X Room Name Pick up Stix Time of Peak Jul 10 am Floor Area 540 Outdoor Dry Bulb Temperature 93 OF Indoor Dry Bulb Temperature 74'F Outdoor Wet Bulb Temperature 73 Conduction Roof Clear Area 540.0 429.0 56.0 56.0 56.0 56.0 56.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value X 0.0360 X X X 0.0740 X X 0.6600 X X 0.6600 X X 0.6600 X 0.6600 X X 0.6600 X X X 0.706 X X 56.0 DETD 1 59.4 = 63.4 = 14.0 = 14.0 = 14.0 = 14.0 = 14.0 = Page Total Orientation Area X X X X X x x x X X SGF X X X X X X x x X X SC Weighting X X x x x X X X X X Factor = = = = = (E) 56.0 169 0.813 0.706 (E) 56.0 169 0.813 0.706 (E) 56.0 169 0.813 0.706 (E) 56.0 169 0.813 0.706 U 56.0 169 0.813 0.706 Page Total Btu/hr 1,156 2,013 517 517 517 517 517 5 755 Btu/hr 5,432 5,432 5,432 5,432 5,432 27 159 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor i hts 1.0 x 540 X 1.200 Watts/sgft x 3.41 Btuh/Watt x 1.000 = 2,211 ccu ants 1.0 X 540 X 230 Btuh/OCC. / 2 Sgft/OCC. X 1.00 = 4,436 Receptacle 1.0 X 540 X 0.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 0 rocess 1.0 x 540 X 2.000 Watts/sgft x 3.41 Btuh/Watt x 1.00 = 3,686 Infiltration: I 1.0o x 1.064 x Sao x 13.00 x o.00 /601 x chedule Air Sensible Area Ceiling Height ACH QT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 43,246 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 x 540 x 1901 Btuh/occ. / 28 Sgft/occ. = 3 664 Receptacle 1.00 x x 0.000 Watts/sgft x Btuh[Watt = Process 1.00 X 540 X 0.000 Watts/sqft x 3.413 Btuh/Watt = o Infiltration: x 4:77 x x x / 6] x Z_ chedule Air Latent Area Ceiling Height ACH QW ROOM COOLING PEAK LOADS Project Title Washington Park - Pad 6 Shell Package Date 6/30/2006 ROOM INFORMATION DESIGN CONDITIONS Room Name Pick up Stix Time of Peak Jul 2 pm Floor Area 670 Outdoor Dry Bulb Temperature 111 '� Indoor Dry Bulb Temperature 74`k Outdoor Wet Bulb Temperature 78 OF Conduction -30 Roof -19 Wall .19.24.16 Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 0.0360 0.0740 DETD t 78.2 = 36.9 = Page Total Weighting Orientation Area SGF SC Factor x x x = x x x = x x x = x x x = x x x = x x x = X x x = X x x = X x x = X x x = Page Total Btu/hr 1,887 1,598 3 485 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor i hts 1.0 x 670 x 1.600 Watts/sgft x 3.41 Btuh/Watt x 1.000 = 3,658 ccu ants 1.0 x 670 x 230 Btuh/OCC. / 15 sgft/occ. x 1.00 = 1,027 Receptacle 1.0 x 670 X 5.000 Watts/sgft x 3.41 Btuh/Watt x 1.00 = 11,434 rocess 1.0 X 670 X 5.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 11,434 Infiltration: 1.00 X 1.064 x 670 x 13.00 x 0.00 /601 X 38 = chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 31,038 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 X 670 X 1901 Btuh/OCC. / 150 sqft/occ. = 849 Receptacle 1.00 x x4-00 Watts/!sqft x I 341d Btuh/Watt = rocess 1.00 x 670 X 0.000 Watts/sgft x 1 3.4131 Btuh/Watt = 0 Infiltration: x a 77 x x x / 6] x ®_ chedule Air Latent Area Ceiling Height ACH pW ROOM COOLING COIL LOADS Project Title Washington Park - Pad 6 Shell Package 24.0 54.0 Date 6/30/2006 7] ROOM INFORMATION DESIGN CONDITIONS (W) Room Name Vanilla Shell Time of Peak Aug 4 pm Floor Area 1,496 Outdoor Dry Bulb Temperature 111 �: Indoor Dry Bulb Temperature 74OFOutdoor Wet Bulb Temperature 78 `k Conduction -30 Roof -19 Wall .19.2x6.16 Double Clear Defauft NM Double Clear Default NM ouble Clear Default NM -19 Wall .19.2x6.16 Double Clear Default NM Double Clear Default NM Double Clear Default NM Area 1,496.0 288.0 24.0 54.0 24.0 487.0 56.0 56.0 54.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Orientation Area (S) 24.0 54.0 (S) (S) 24.0 (W) 56.0 (W) 56.0 (W) 54.0 (W) 56.0 (N) 56.0 U -Value SGF x 29 x 29 x 29 x 230 x 230 X 236 X 230 X 28 X X 0.0360 0.0740 x 0.813 x 0.813 X 0.813 x 0.813 X 0.813 x 0.813 x 0.813 X 0.813 X X DETD 1 60.4 = 56.2 = 27.4 = 27.4 = 27.4 = 27.4 Page Total Weighting Factor X 1.816 = X 1.668 = X 1.816 = X 0.442 = X 0.442 = X 0.450 = X 0.442 = X 1.084 = X X Page Total Btu/hr 3,255 1,198 435 978 435 3.1861 1,0141 1.014 978 12 492 Btu/hr 1,043 2,122 1,043 4,622 4.622 4,667 4 622 1 381 24 123 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor fights 1.0 X 1,496 X 1.500 Watts/sgft X 3.41 Btuh/Watt X 1.000 = 7,658 ccu ants 1.0 X 1,496 X 230 Btuh/OCC. I sgft/occ. X 1.00 = 7,820 Receptacle 1.0 X 1,496 x 0.000 Watts/sqft X 3.41 Btuh/Watt X 1.00 = 0 rocess 1.0 X 1,496 x 2.000 Watts/sqft X 3.41 Btuh/Watt X 1.00 = 10,212 Infiltration:1.00 x 1.064 x 1 496 x 13.00 x 0.00 /601 x 38 = Ledule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 65,395 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 x 1,4961 x 190Btuh/occ. / 44 sgft/occ. = s aso Receptacle 1.00 x x Watts/sgft x Btuh/Watt = rocess 1.00 X 1,496 X 0.000 Watts/sgft x 1 3.4131 Btuh/Watt = 0 Infiltration: x 4.77 x 1 496 x x / 6] x ®_ chedule Air Latent Area Ceiling Height ACH Qyy TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6460 EnergyPro By EnergySoft User Number: User 05-068 Page:39 of 44 ROOM COOLING COIL LOADS Project Title Washington Park - Pad 6 Shell Package DETD 1 Date I 6/30/2006 ROOM INFORMATION DESIGN CONDITIONS 27.4 Room Name Vanilla Shell Time of Peak Aug 4 pm Floor Area 1,496 Outdoor Dry Bulb Temperature 111 `k Indoor Dry Bulb Temperature 74`F Outdoor Wet Bulb Temperature 78 `k Conduction bouble Clear Default(NM) -19 Wall (W.19.24.16) Area 56.0 334.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 1 0.07401 X X X X X X X X X DETD 1 = = = = = = = = = 27.4 43.0 27.4 Page Total Weighting Orientation Area SGF SC Factor x x x x x x = x x x = x x x = x x x = x x x = x x x = x x x = x x x = x x x = Page Total Btu/hr 1,014 1,062 1,014 3 091 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor i hts 1.0 X 1,496 X 1.500 Watts/sgft X 3.41 Btuh/Watt X 1.000 = 7,658 ccu ants 1.0 x 1,496 x 230 Btuh/occ. / sgft/occ. x 1.00 = 7,820 Receptacle 1.0 X 1,496 x 0.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 0 rocess 1.0 x 1,496 x 2.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 10,212 Infiltration: 1.00 x 1.064 x 1 496 x 13.00 x 0.00 / 60] x 38 = 0 chedule Air Sensible Area Ceiling Height ACH QT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 65,395 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 x 1496 x 1901 Btuh/OCC. / 44 sgft/occ. = 6460 Receptacle 1.00 x x 0.00oi Watts/sqft x Btuh/Watt = Process 1.00 X 1,496 X 0.000 Watts/sgft x 3.413 Btuh/Watt = o Infiltration: x 4 77 x 1x496 x x / 6] x ®_ chedule Air Latent Area Ceiling Height ACH Qyy ROOM COOLING COIL LOADS Project Title Washington Park - Pad 6 Shell Package X X X X X X X X X Date 6/30/2006 ROOM INFORMATION DESIGN CONDITIONS 0.0360 Room Name Port Of Sub Time of Peak Jul 3 pm Floor Area 1,362 Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 749F Outdoor Wet Bulb Temperature 78 `k Conduction -30 Roof -19 Wall .19.2x6.16 Double Clear Default NM Double Clear Default NM Double Clear Default NM Double Clear Default NM Double Clear Default NM -19 Wall .19.2x6.16 Area X X X X X X X X X U -Value X X X X X X X X X 1,362.0 0.0360 134.0 0.0740 36.0 0.6600 36.0 0.6600 54.0 0.6600 36.0 0.6600 36.0 0.6600 332.0 0.0740 42 0.813 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Orientation Area X X X X X x x X X x SGF X X X X X X x x X x SC (S) 36.0 42 0.813 (S) 36.0 42 0.813 (S) 54.0 42 0.813 (S) 36.0 42 0.813 (S) 36.0 42 0.813 DETD 1 73.6 = 101.7 = 27.5 = 27.5 = 27.5 = Page Total Weighting Factor x 0.868 = x 0.868 = x 0.868 = X 0.868 = X 0.868 = X X x x X Page Total Btu/hr 3,609 1,009 654 654 982 654 654 943 9 160 Btu/hr 1,066 1 M6 1,600 1,066 1,066 5 865 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor i hts 1.0c X 1,362 X 1.200 Watts/sqft X 3.41 Btuh/Watt x 1.000 = 5,578 ccu ants 1.0c X 1,362 X 230 Btuh/occ. / 2 sgft/occ. X 1.00 = 11,188 Receptacle 1.0 x 1,362 x 0.000 Watts/sqft x 3.41 Btuh/Watt X 1.00 = 0 rocess 1.0c x 1,362 x 2.000 Watts/sgft X 3.41 Btuh/Watt X 1.00 = 9,297 Infiltration: 1.00 x 1.064 x 1 362 x 13.00 x 0.00 /601 x 38 = 0 chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 41,088 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 x 1 362 X 1901 Btuh/occ. / 28 sgft/occ. = 9 242 Receptacle 1.00 x x0-000 Watts/sgft x Btuh/Watt= Process 1.00 x 1,362 x 0.000 Watts/sgft X 1 3.413 Btuh/Waft = o Infiltration: �� x 4771 /6 x x x ] x A _ chedule Air Latent Area Ceiling Height ACH W ROOM COOLING COIL LOADS Project Title Washington Park - Pad 6 Shell Package X X X X X X X X X Date I 6/30/2006 ROOM INFORMATION DESIGN CONDITIONS 0.0360 Room Name Pickup Stix Time of Peak Jul 3 pm Floor Area 1,015 Outdoor Dry Bulb Temperature 112 `k Indoor Dry Bulb Temperature 74'� Outdoor Wet Bulb Temperature 78 91Z Conduction -30 Roof -19 Wall .19.2x6.16 Double Clear Defauft NM Double Clear Default NM Double Clear Default NM ouble Clear Default NM Double Clear Default NM Area X X X X X X X X X U -Value X X X X X X X X X 1,015.0 0.0360 387.0 0.0740 36.0 0.6600 54.0 0.6600 36.0 0.6600 36.0 0.6600 36.0 0.6600 0.868 (S) 36.0 42 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain DETD 1 73.6 = 62.1 = 27.5 = 27.5 = 27.5 = 27.51 = 27.5 = Page Total Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC Weighting X X X X X X X X X X Factor = = = = = (S) 36.0 42 0.813 0.868 (S) 54.0 42 0.813 0.868 (S) 36.0 42 0.813 0.868 (S) 36.0 42 0.813 0.868 (S) 36.0 42 0.813 0.868 Page Total Btu/hr 2,689 1,777 654 982 654 654 654 8 066 Btu/hr 1,066 1,600 1,066 1,066 1,066 5 865 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0 X 1,015 X 1.200 Watts/sqft x 3.41 Btuhfwatt X 1.000 = 4,157 ccu ants 1.0 X 1,015 X 230 Btuh/OCC. / d3.41 sqft/occ. x 1.00 = 8,338 Receptacle 1.0 X 1,015 x 0.000 Watts/sgft x Btuh/Watt X 1.00 = 0 rocess 1.0 x 1,015 x 2.000 Watts/sgft x Btuh/Watt x 1.00 = 6,928 Infiltration: 1.00 x 1.064 x 1 015 x 13.00 x 0.00 /601 x 38 = chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 33,353 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 1,0151 X 1901 Btuh/OCC. / 28 sgft/OCc. = 6 888 Receptacle 1.00x x Watts/sgft x Btuh/Watt = Process 1.00 X 1,015 X 0.000 Watts/sgft X 1 3.4131 Btuh/Watt = o Infiltration: [� x a 77 x � x x o.00 / 6] x ®_ Schedule Air Latent Area Ceiling Height ACH pW ROOM COOLING COIL LOADS Project TitleDate Washington Park - Pad 6 Shell Package X X X X X X X X X 6/30/2006 ROOM INFORMATION DESIGN CONDITIONS 0.0360 Room Name Pick up Stix Time of Peak Jul 1 pm Floor Area 540 Outdoor Dry Bulb Temperature 108 9F Indoor Dry Bulb Temperature 74`F Outdoor Wet Bulb Temperature 77 Conduction Roof Clear Area X X X X X X X X X U -Value X X X X X X X X X 540.0 0.0360 429.0 0.0740 56.0 0.6600 56.0 0.6600 56.0 0.6600 56.0 0.6600 56.0 0.6600 1.884 (E) 56.0 49 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain DETD t 79.0 = 62.6 = 24.2 = 24.2 = 24.2 = 24.2 = Page Total Orientation Area X X X X x X x X X X SGF X X X X X X x x X X SC Weighting x x X X x X X X X x Factor = = = = = = = (E) 56.0 49 0.813 1.884 (E) 56.0 49 0.813 1.884 (E) 56.0 49 0.813 1.884 (E) 56.0 49 0.813 1.884 (E) 56.0 49 0.813 1.884 Page Total Btu/hr 1,536 1,986 895 895 895 895 895 7 997 Btu/hr 4,202 4,202 4,202 4,202 4,202 21 010 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0 X 540 X 1.200 Watts/sgft x 3.41 Btuh/Watt X 1.000 = 2,211 ccu ants 1.0 X 540 X 230 Btuh/OCC. / 2 sgft/occ. x 1.00 = 4,436 ece tacle 1.0 x 540 x 0.000 Watts/sgft x 3.41 BtuhfWatt x 1.00 = 0 rocess r.0 x 540 x 2.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 3,686 Infiltration: I 1.00 x 1.064 x 540 x 13.00 x 0.00 /601 x -Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 39,340 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 X 540 x 190 Btuh/OCC. / 28 sgft/occ. = 3 664 ece tacle 1.0o x x 0.000 Watts/sgft x 3 413 Btuh/Watt = rocess 1.00 x Sao x 0.000 Wafts/sgft x 3.4131 Btuhiwatt = o Infiltration: 1.0o x Latent x � x x � / 6] x � _ chedule Air Latent Area Ceiling Height ACH Qyy TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3.6641 EnergyPro By EnergySoft User Number: User 05-068 Page:43 of 44 ROOM COOLING COIL LOADS Project Title Washing`on Park - Pad 6 Shell Package Date 6/30/2006 ROOM INFORMATION DESIGN CONDITIONS Room Name Pickup Stix Time of Peak Jul 3 pm Floor Area 670 Outdoor Dry Bulb Temperature 112 9F Indoor Dry Bulb Temperatiiire 74`F Outdoor Wet Bulb Temperature 78 `k Conduction Roof Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 1 0.03601 DETD 1 X 73.6 = X 38.4 = X = X = X = X = X = X = X = Page Total Weighting Orientation Area SGF Sc Factor x x x = x x x = x x x = x x x = x x x = x x x = x x x = x x x = x x x = x x x = Page Total Btu/hr 1,775 1,662 3 438 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor i hts 1.0 X 670 X 1.600 Watts/sqft X 3.41 Btuh/Watt X 1.000 = 3,658 ccu ants 1.0c x 670 x 230 Btuh/occ. / 15 sgft/occ. x 1.00 = 1,027 Receptacle 1.0 x 670 X 5.000 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 11,434 rocess 1.0 x 670 x 5.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 11,434 Infiltration: Ledule0 x Air Sensible x Area Ceiling X Ceiling Helgho X ACH 00 / s] X QT 38 Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 30,990 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 X 670 X 1901 Btuh/OCC. / 150 sgft/occ. = 849 Receptacle 1.00 x x Watts/sqft x Btuh/Watt = Process 1.00 X 670 X 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: x a 77 x x 3 Q x / 6] x ®_ chedule Air Latent Area Ceiling Height ACH pW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 979961 EnergyPro By EnergySoft User Number: User 05-068 Page:44 of 44 771 CERTIFICATE'OF COMPLIANCE Desert Sands Unified School District �4G'c„��y� 47950 Dune Palms Road ¢ BERMUDA DUNES t" rn RANCHO MIRAGE (� Date 11/8/06 La Quinta, CA 92253 (,� INDIAN WELLS No. 29028 (760) 771-8515 `w> PALM IQUINT �y INDIO y7 o Owner Washington 111, Ltd , APN # 643-020-027 Address 30246 Rancho Viejo Road, Ste. B Jurisdiction La Quinta City San Juan Capi Zip 92675 Permit # Tract # - Study Area Type Commercial No. of Units Lot # No. Street - S.F. Lot # No. Street S.F. Unit 1 46520 Washington St. 5263 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 ' Unit 4 Unit 9 Unit 5 Unit 10 Comments ; At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/Walkways, residential additions under 5 00 square feet, .detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. • in the amount of $0.42 X 5,263 S.F. or $2,210.46 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By O/C City National Bank, Bill Sanchez Check No. 240501629 Name on the check Telephone 342-2674 Funding Commercial By Dr. Doris Wilson• E ' Superintendent`'`"� Fee collected /exe pted by pat ICIa Barbuzza Payment Recd '40-00 = y /U $2,210:46 "''Overnder rt.y n Signature ��, �„ •�i+ NOTICE: Pursuant to Government Code Sectidfi 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant . Copy - Applicant/Receipt Copy - Accounting