06-0431 (CSCS)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
,,Application Number: 06-00000431]
Property Address: r 46660 WASHINGTON ST
APN: 643-020-999-3 -30903.-
Application description: NEW COMML - STORES & CUSTOMER
Property Zoning: REGIONAL COMMERCIAL
Application valuation: 798263
Applicant:
Architect or Engineer:
SERVICE
Owner:
WASHINGTON 111 LTD
L24
JACK TARR
0 RANCHO VIEJO RD
JUAN CAPISTRANO,
. STE. B
CA 92675
CONSTRUCTION, INC
IRVINE, CA 92618;
(949)587-2206
Lic. No.: 355353
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 1/02/07
LICENSED CONTRACTOR'S DECLARATION
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
I hereby affirm under penalty of perjury one of the following declarations: '
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full farce and effect.
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
License Class: B License No.: 355353
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
'
- on - . -
issued.
�I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
'
Code, for the performance of the work for which this permit is issued. My workers' compensation
OWNER -BUILDER DECLARATION
insurance carrier and policy number are:
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
Carrier ABD INS Policy Number 71WC12012701
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
person in any manner so as to become subject to the workers' compensation laws of California,
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
and agree that, if I should become subject to the workers' compensation provisions of Section
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
- 3700 of the Labor Code, I shall forthwith comply with those provisions.
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
f�
I /�
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
a
ate: ppticant: n
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
( I, as owner of the property, am exclusively contracting with'licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
(((/// property who builds or improves thereon, and who contracts for the projects with a contractorls) licensed
pursuant to the Contractors' State License Law.).
( ) I am exempt under Sec. , B.&P.C. for this reason '
Date: l' 17.e 7 ner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPE%NIIT
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL '
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety fora permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant.to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
'city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter upon the above-mentioned property for inspection purposes. -
�Oate: � ignature (Applicant or Agentl: 8AP
(/(J
Application Number .
. . . . 06-00000431
------ Structure Information
SHELL BUILDING 15850 SF
-----
Other struct info . .
. . . CODE EDITION
2001/04E/05 EN
_
FIRE SPRINKLERS
YES
MIXED-USE OCCUPANCY
SHELL
OCCUPANT LOAD
.00
PATIO SQ FTG
1482.00
1
----------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
15850.00
Permit
BUILDING PERMIT
Additional desc ...SHELL
BUILDING
Permit Fee . . . .
2936.50 Plan Check Fee
1908.73
Issue Date
Valuation
798263
Expiration Date ..
7/01/07
Qty Unit Charge
Per
Extension
BASE FEE
2039.50
299.00 3.0000
------------------------------------------------------------------------------
THOU BLDG 500,001-1,000,000
897:00
Permit . .
ELEC-NEW COMMERCIAL
Additional desc
Permit Fee
332.00 Plan Check Fee..
83.00
Issue Date . . .'
Valuation
. . 0
Expiration Date
7/01/07 .
Qty. Unit'Charge
Per,
Extension
BASE FEE
15.00
15850.00 .0200
ELEC GARAGE OR NON-RESIDENTIAL
317.00
Permit . . ,
MECHANICAL
Additional desc .
Permit Fee . . .
273.00 Plan Check Fee
. 68.25
Issue Date . . . .
Valuation
. . 0
Expiration Date..
7/01/07
Qty Unit Charge
Per
Extension `
BASE FEE
15.00
10.00' 9..0000
EA MECH FURNACE <=100K
90.00
10.00• 9.0000
EA MECH B/C <=3HP/100K BTU
90.00
12.00 6.5000
EA MECH WENT FAN
78.00
Permit
PLUMBING
Additional desc .
Permit Fee . . . .
408.00 Plan Check Fee
102.00
LQPERA11T
Application Number. . . . . . 06-00000431
Permit . . . . . . PLUMBING
_ Issue Date . . . . Valuation . . .
0
Expiration Date 7/01/07
Qty Unit Charge Per
Extension
BASE FEE
15.00
24.00 6.0000'EA PLB FIXTURE
144.00
rt, 1.00' 15.0000 EA PLB BUILDING SEWER
15.00"
5.00 6.0000 EA PLB ROOF DRAIN'
30.00
12.00 7.5000 EA PLB WATER HEATER/VENT
90.00
3.0000 EA PLB WATER INST/ALT/REP
30.00
•10.00
1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM
9.00
10.00 7.5000 EA PLB•OTHER BACKFLOW <=2 INCH
75.00
Permit . . . ... GRADING PERMIT
Additional desc .
Permit Fee-_ 15.00 Plan Check Fee
.00
Issue Date. Valuation
0
Expiration Date 7/01/07
Qty' Unit Charge Per
Extension
BASE FEE
15.00
Special Notes and Comments
COMMERCIAL "SHELL'" BUILDING 15,850.SF
AREA-. TYPE V-N CONSTRUCTION WITH
SPRINKLER CREDIT FOR ALLOWABLE AREA
(M/A-3 PROPOSED USES.6,000SF X 3 =
18,000 ALLOW. AREA PERCBC505.3);,
2001 CBC,CMC,CPC, 2004 CEC, 2005 ENERGY
CODES. 2005 D.I.F.ASSESSED.**PERMIT
DOES NOT INCLUDE TEMPORARY POWER, BLOCK
. WALLS, TRASH ENCLOSURES, COVERED
PARKING AND -SITE LIGHTING.**
Other'.Fees . . ACCESSIBILITY PLAN REVIEW
190.87
ART IN PUBLIC PLACES-COM
3971.31
DIF CIVIC CENTER - COMM
2472.60
ENERGY REVIEW FEE
190.87
- DI.F FIRE PROTECTION-COMM
713.24
STRONG MOTION (SMI) = COM
167.63'
DIF STREET MAINT FAC-COMM
1680.10
DIF TRANSPORTATION - COMM
41717.19
Fee summary Charged Paid Credited
Due
Permit Fee Total 3964.50 .00 .00
3964.50
LQPEW%IIT
r
j
Po. BOX 1504 APPLICATION ONLY
Building
78-495 CALLE TAMPICO.
Address e.7 LA QUINTA, CALIFORNIA 92253
Mailing
Address 30
Cityft I/
I.
Ci Zip
zjtate LIC. City
& Classif. I Lic. #
Designer
Address
City — Zip State
CarlrNe 1 C4 1
Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and
effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencinwith Section 7000) of
Division 3 of the Business and Professions Code, or that he is exempt thg erefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).
I, as owner of the property, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes-
sions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon and who does such work himself or through his own employees, provided
that such improvements are not intended or offered for sale. It, however, -the building or Im-
provement is sold within one year of completion, the owner -builder will have the burden of
proving that he did not build or improve for the purpose of sale).
O 1, as owner of the property, am exclusively contracting with licensed contractors to construct
the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does
not apply to an owner of property who builds or improves thereon, and who contracts for such
projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
O Copy is filed with the city. O Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars (5100) valuation
or less).
I certify that in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to Workers' Compensation Laws of
California.
Date Owner
NOTICE TO APPLICANT.. If, after making this Certificate of Exemption you should become
/subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work
for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
WHITE = BUILDING DEPARTMENT
BUILDING: TYPE CONST. ,' P.
V OCC. GR
A.P. Number 6413- 3- aw. oo n Q
Legal Description /3!
Project Description "WaWAMM Al
Sq. Ft. ��!� No. / No. Dw.
New
,X Add ❑ Alter ❑ Repair ❑ Demolition ❑
Estimated Valuation
PERMIT
Plan Chk. Dep.
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
TOTAL _
REMARKS I It°IiY OF
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by: Date
Validated
Validation:
YELLOW = APPLICANT PINK = FINANCE
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road ¢ BERMUDA DUNES r
Q0 RANCHO MIRAGE
Date 11/9/06 La Quinta, CA 92253 E. INDIAN WELLS
No. 29030 (760) 771-8515 d�
PALM LA OUINTA� �y
PINDIO y�
p
Owner Washington 111, Ltd. APN # 643-020-027
Address 30240 Rancho Viejo Road, Suite B f • Jurisdiction La Quinta
city San Juan Capi Zip 92675 Permit #
Tract # Study Area
Type Commercial ° No. of Units a
Lot # No. Street S.F. Lot # No. Street S.F.
Unit 1 46-660 Washington St 15850 k Unit 6
Unit 2 Unit 7
Unit 3 Unit 8 r
Unit 4. Unit 9
Unit 5 Unit 10
Comments -
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION_ NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.42 X 15,850 S.F. or $6,657.00 have been paid for -the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By O/C City National Bank, Amanda Snyder Check No. 240501633
Name on the check Telephone 775-7967
Funding Commercial
By Dr. Doris Wilson
Superintendent
Fee collected /exem d b Payment Recd'
y Patri 'a Barbuzza � y
$6,657.00 Over/u de1-,
Signature
NOTICE: Pursuant to Government Code Section 6 1)0(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees o
r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting
John R. Hawkins
Fire Chief
Proudly serving the
Unincorporated
Areas of Riverside
County and the
Cities of:
Banning
Beaumont
Calimesa
Canyon Lake
Coachella
4.
Desert Hot Springs
Indian Wells
Indio
Lake Elsinore
La Quinta
4.
Moreno Valley
Palm Desert
Perri s
Rancho Mirage
San Jacinto
Temecula
Board of Supervisors
Bob Buster,
District 1
John Tavaglione,
District 2
Jim Venable,
District 3
Roy Wilson,
District 4
Marion Ashley,
District 5
RIVERSIDE COUNTY FIRE DEPARTMENT
- 1 1, _ In cooperation..wth the
California Department of Forestry and Fire Protection
210 West San Jacinto Avenue • Perris, California 92570 • (909) 940-6900 • Fax (909) 940-6910
December 1, 2006
To: City of La Quinta
Building Department
Re: Release for Building Permits
LAQ-05-BP-047; LAQ-06-BP-027 & LAQ-06-010 / Washington Park
X16 66fb1`�.si, j' %--630 i��:�ti: �d-toe i✓;y,,
The Riverside County Fire Department hereby releases the above referenced project for issuance of a
building permit at the discretion of the Building Department.
Respectfully,
0
Tracy Hobday
Chief Fire Department Planner
By
Sonia Coole
Fire Safety Specialist
oEc
HAPE2\GENERALIF0RMS\BIdg Permit Release - LO.doc
EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE
82-675 Highway 111, 2"d FI., Indio, CA 92201 • (760) 863-8816 • Fax (760) 863-7072
John R. Hawkins
Fire Chief
Proudly serving the
Unincorporated
Areas of Riverside
County and the
Cities of.
Banning
Beaumont
Calimesa
Canyon Lake
Coachella
Desert Hot Springs
Indian Wells
Indio
4.
Lake Elsinore
La Quinta
Moreno Valley
❖
Palm Desert
Perris
Rancho Mirage
4.
San Jacinto
Temecula
Board of Supervisors
Bob Buster,
District 1
John Tavaglione,
District 2
Jim Venable,
District 3
Roy Wilson,
District 4
Marion Ashley,
District 5
RIVERSIDE COUNTY FIRE DEPARTMENT
M cooperation with the
California Department of Forestry and Fire Protection
210 West San Jacinto Avenue - Perris, California 92570 - (909) 940-6900 - Fax (909) 940-6910
December 1, 2006
j sT „.S4Vs-3Y
Washington 111, Ltd yC. -- 6 36 J% 5'
30240 Rancho Viejo Road, Bldg B
San Juan Capistrano, CA 92675
Re: Water System Plan Review
PM 32683 (LAQ-05-BP-047, LAQ-06-BP-027, LAQ-06-BP-010)
Washington Park, La Quinta, CA
The above referenced water plans have been reviewed and are acceptable by the Riverside County
Fire Department.
The County Fire Department must witness the following tests:
1 A hydrostatic test of 200 -psi pressure for two (2) hours or at 50 psi in excess of the
maximum static pressure when it is in excess of 150 psi shall be witnessed by a fire
inspector prior to covering piping joints.
2. System flush inspection.
3. A final inspection is required.
Blue retro -reflective pavement markers shall be mounted on private streets, public streets and
driveways to indicate location of fire hydrants.
All questions regarding the meaning of these conditions should be referred to the Fire Department
Planning & Engineering staff at (760) 863-8886.
Sincerely,
Tracy Hobday
Chief Fire Department Planner
Byj��.
Sonia Cooley
Fire Safety Specialist l
EMERGENCY SERVICES DIVISION - PLANNING SECTION . INDIO OFFICE
82-675 Highway 111, 21d FI., Indio, CA 92201 - (760) 863-8886 - Fax (760) 863-7072
04/27/2006 13:13 949-222-0771 HFTA° PAGE 01/05
SLADDEN ENGINEERING'
(750} 772-3893- - (760) 772-3895 FAX
FACSIMILE TRANSMITTAL SHEFT
TO; FRGM;
Brett •Andemon
COMPANY: DAM
RAX NUMBE4, TOTAL NO. OF PAGES INCLUDING COVER:
uu..�in *ngnu, r• SENDER'S RUERCNGIi, NUMIblilt
TA:
70UR MFULNCic i=vi•iocn:
❑ URGENT 0 Fop Rwvlm ❑ ISL ASt COMMENT liFLEAS RFPIN ❑ PUAsh Kxt.Y(:LL: ,
NOTES/COMMENTS;
k
Post -Ito Fax Note 7671
Pages
n r
To
Fromm ,n I i
+ , rr,,
alji
Phone i4
Phone 11
Fax 11
FIX ft
ii-iZ1 vAli.NAD L,A1VZUAA4
PALM RESERT, CALIFORNIA 92219 1,
G d E l00ZLZ089 �PIl9�: l l
U/LS:l 1900Z ZZ WOW 1a3S30 w1U. N3aQd1S W08�
TITLE 24 REPORT
Title 24 Report for:
Washington Park - Shops 4
46-660 Washington Street
La Quinta, CA 92253
Project Designer: ,
KKE Architects, Inc
525 East Colorado Boulevard (Fourth Floor)
Pasadena, CA 91101 .
(626) 796-8230.
Report Prepared By:
SIA GARESTANI, P.E.
SPEC Engineering
6800 Owensmouth Ave. #140
Woodland Hills, CA 91303
(818) 592-6643
CITY OF LA QUINTA
Job Number: BUILDING & SAFETY DEPT.
06-002 APPROVED
.FOR CONSTRUCTION
Date:
DATE % OZ D BY /L
. 5/9/2006
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.1 by EnergySoft Job Number: 06-002 User Number: 3358
46 ' �BColJ 6t/ril/Gz/ „ o�F� N
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Nonresidential Performance Title 24 Forms 3
Form ENV -MM Envelope Mandatory Measures 19
Form MECH-MM Mechanical Mandatory Measures 20
HVAC System Heating and Cooling Loads Summary 22
1
EnergyPro 4.1 by EnergySoft Job Number: 06-002 User Number: 3358
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1
PROJECT NAME
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
DATE
Washington Park - Shops 4
DATE OF PLANS
05-08-06
5/9/2006
PROJECT ADDRESS
]CLIMATE
—
46-660 Washington Street La Quinta
NONRESIDENTIAL HIGH RISE RESIDENTIAL E]
HOTEUMOTEL GUEST ROOM
PRINCIPAL DESIGNER -ENVELOPE
TELEPHONE
Buildmg'Permd #
KKE Architects, Inc
(626) 796-8230
California as a civil engineer, mechanical engineer, or I am a licensed architect.
DOCUMENTATION AUTHOR
TELEPHONE
Checked by/Date
SPEC Engineering
(818) 592-6643
EnfonementAg6 Cy Use`"
GENERAL INFORMATION
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations. This certificate applies only to a Building using the performance compliance approach.
The documentation preparer hereby certifies that the documentation is accurate and complete.
DATE OF PLANS
05-08-06
BUILDING CONDITIONED FLOOR AREA
15,947 Sq.Ft.
]CLIMATE
ZONE
15
BUILDING TYPE
NONRESIDENTIAL HIGH RISE RESIDENTIAL E]
HOTEUMOTEL GUEST ROOM
PHASE OF CONSTRUCTION
NEW CONSTRUCTION ADDITION
E]
EXISTING + ADDITION/ALTERATION
STATEMENT OF COMPLIANCE
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations. This certificate applies only to a Building using the performance compliance approach.
The documentation preparer hereby certifies that the documentation is accurate and complete.
DOCUMENTATION AUTHOR
SIGNATURE
DATE
SIA GARESTANI P.E.
12/04/06
The Principal Designer hereby certifys that the proposed building ep n in this set of construction documents is
consistent with the other compliance forms and worksheets, with pecifications, and with any other calculations submitted with this
permit application. The proposed building as designed meets energy efficiency requirements contained in sections 110, 116,
through 118, and 140, 142, 143 or 149 of Title 24, Part 6.
ENV. LTG. MECH.
❑ n F-] 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to
sign this document as the person responsible for its preparation; and that I am licensed in the State of
California as a civil engineer, mechanical engineer, or I am a licensed architect.
❑ n F] 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section
5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed
contractor performing this work.
F1 ❑ R 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document
because it pertains to a structure or type of work described as exempt pursuant to Business and Professions
Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in
full in the Nonresidential Manual.)
ENVELOPE COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
ENV -1
Required Forms
PRINCIPAL ENVELOPE DESIGNER - NAME
SI LIC. NO. DATE
KKE Architects Inc
Z
LIGHTING COMPLIANCE
Indicate location on.plans of Note Block for Mandatory Measures
Lighting Compliance Not In The Scope Of
h1SSubmitt aI
Required Forms
PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE
LIC. NO. DATE
MECHANICAL COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
ME -1 H-2 MECH-3, MECH-5
Required Forms
PRINCIPAL MECHANICAL DESIGNER -NAME
SIGNATURE
LIC. NO.
DATE
SIA GARESTANI P.E.M26426
12/04/06
- EnergyPro 4.1 by EnergySoft User Number: 3358` Job Number: 06-002 Page:3 of 31 1
PERFORMANCE CERTIFICATE OF COMPLIANCE- Part 2 of 3 PERF -
PROJECT NAME DATE
Washington Park - Shops 4 5/9/2006
ANNUAL TDV ENERGY USE SUMMARY kBtu/s ft- r -
ENERGY COMPONENT
Standard
Design
-
..
'
Proposed
Design
1
Compliance
Margin
10
0
(:_:sgg- bId, W Proposed.
pace Heating
rSpace Cooling
11
'Indoor Fans
Heat Rejection
Pumps & Misc.
Domestic Hot Water
Lighting
Receptacle
Process
TOTALS: f'
Percent better than Standard:
0.43
0.31
012`x5
ssp,
IWOR
t »
I2U`1not601aoz0oz20za02802eo300:•..
ke�ulegfi:yr,
process) '
, • • 311.60
281.09
- 30.51
36.75
39.99
-3.24rill
0.00
0.00
0.00
0.00
0.00
0.00
58.8355.77
118
3.06
165.26
165.26
0.00
82.18
82.18
000M��<,''
o.00
o.00
o.00
655.05
624.60
-30.45
4.6%
( 4.6% excluding
01111 r11Al^ f%1^111/lnli Ire
Building Orientation
Number of Stories
Number of Systems
Number of Zones
w 270 deg
Conditioned Floor Area •
Unconditioned Floor Area
Conditioned Footprint Area
Fuel Type
15,947
sqft.
sqft.
sqft.
1
o
10
0
10
Natural Gas
sqft.
46.6%
Standard Proposed
Lighting Power Density 1.500 W/sqft. 1.500 W/sqft.
Prescriptive Env. Heat Loss 2,072 Btu/h 2,979 Biu/'h _
Prescriptive Env. Heat Gain 228,595 Btu/h-F 317,890 Btu/h-F
Remarks:
Run Initiation Time: 05/09/06 16:15:26 Run Code: 1147211
EnergyPro 4.1 by EnergySoft User Number: 3358 - Job Number: 06-002
tof31
I
Orientation
Gross Area
Glazing Area
Glazing Ratio
'Front Elevation
w
2,379
sqft.
1,108
sqft.
46.6%
Left Elevation '
f (N)
857
sqft.
0
sqft.
0.0%
'
Rear Elevation'
E
2,720
sqft.
118
sqft.
4.3%
Right Elevation •`-
(S)
.1023
sqft.
416
sqft.
40.7%
Total
x,979
sqft.
1,642
sgft.
Roof
..
15,947
sqn:
" _ 7 o
sqft.
o.o°i°
Standard Proposed
Lighting Power Density 1.500 W/sqft. 1.500 W/sqft.
Prescriptive Env. Heat Loss 2,072 Btu/h 2,979 Biu/'h _
Prescriptive Env. Heat Gain 228,595 Btu/h-F 317,890 Btu/h-F
Remarks:
Run Initiation Time: 05/09/06 16:15:26 Run Code: 1147211
EnergyPro 4.1 by EnergySoft User Number: 3358 - Job Number: 06-002
tof31
I
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1
PROJECT NAME
Washington Park - Shops 4
DATE
5/9/2006
ZONE INFORMATION
System Name
Zone Name
" Floor
Area
Occupancy Type (sgft.)
Inst.
LPD
(W/sf)1
Ctri ' 'Allowed LPD bt
°Credits+ Y Areas Tailored'>Loads
W/s z= ; W/s 3 4:
f 'roc
(W/st7''
RTU -1
Suite 1
Comp Bldg Retail and Wholesale 1,385
*11.5013,
•�' ° +` �'""'v
RTU -2
Suite 2 •
Comp Bldg Retail and Wholesale 1,516
'1.50
RTU -3
Suite 3 '
Comp Bldg Retail and Wholesale 1,516
'1.50
RTU -4
Suite 4
Comp Bldg Retail and Wholesale 1,502
"1.50>
RTU -5
Suite 5
Comp Bldg Retail and Wholesale 1,502
'1.50
Maµ:.
RTU -6
Suite 6
Com Bldg Retail and Wholesale 1,515
'1.50
a.,rP+a .`.,,yam:.,,"..
�.�' �. ��K,"""""'�w, ?�«w�E;e...•,'•
�,•
.
RTU -7
Suite 7
Comp Bldg Retail and Wholesale 1,905
'1.50at
t ^ xAs'
RTU -8
Suite 8 -
Comp Bldg Retail and Wholesale 2,022
-1.50C
RTU -9
Suite
Comp Bldg Retail and Wholesale 1,542
'1.50
RTU -10
Suite 10
Comp Bldg Retail and Wholesale 1,542
'1.50
�+eq.'1F "K _ .•
dS� �%
.
""' ,�.' M . R' kph' � : , J- i �a'-�•.
���.�t�.
�.
•F/,'.fib y{�'11 �j�•?S_�vw.'�
�, .eiR n�9%C
Notes: 1. See LTG -2-C 2. See LTG -4-C 3. See LTG -5-C 4. See LTG -6-C
(items marked with asterisk, see LTG -2 -C by others) (by others)�.°
Items above -require specaal documentabon
s x ,t
EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST
- --- - -- •-••• t1 --y �••��•� r.r �r��,a, a..�„�,�„ �� u,e nuns speumeu in oris cnecKust. i nese items require special written justification
and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of
the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation
submitted.
The HVAC System "CARRIER 50HJ0008” includes Demand Control Ventilation per Standards Section 121.
The Zone "Suite 1" has a North/East/South Display Perimeter Credit of 12 ft.
The Zone "Suite 2" has a North/East/South Display Perimeter Credit of 12 ft.
The Zone "Suite 3" has a North/East/South Display Perimeter Credit of 12 ft.
The Zone "Suite 4" has a North/East/South Display Perimeter Credit of 12 ft. - t
The Zone "Suite 5" has a North/East/South Display Perimeter Credit of 12 ft.
The Zone "Suite 6" has a North/East/South Display Perimeter Credit of 12 ft.
The Zone "Suite 7" has a North/East/South Displ� Perimeter Credit of 31 ft.
The Zone "Suite 8" has a North/East/South Display Perimeter Credit of 28 ft.
The Zone "Suite 9" has a North/EasVSouth Display Perimeter Credit of 12 ft.
The Zone "Suite 10" has a North/East/South Display Perimeter Credit of 12 ft.
• - w—upu-na, leawres nsceu in tms perrormance approach application have specifically been reviewed. Adequate written justification and
documentation for their use have been provided by the applicant. ,
,
(CERTIFICATE OF COMPLIANCE ENV-1-C�
PROJECT NAME DATE
Washiri tctoon Park - Shops 4 5/9/2006
OPAQUE SURFACES
Surface
# Type
Area
U -Fac.
Insulation
Cay. Cont.
Act.
Am.
Tilt
Cond:
Status
Joint Appendix
IV Reference
Location / Comments
1 Wall
250
0.065
R-19
R-0.0
90
90
New
09-A7
Suite 1
2 Wall
129
0.065
R-19
R-0.0
270
90
New
09-A7
Suite 1
3 Roof
1,385
0.034
R-30
R-0.0
0
0
New
02-A26
Suite 1
4 Wall
276
0.065
R-19
R-0.0
90
90
New
09-A7
Suite 2
5 Wall
155
0.065
R-19
R-0.01
270
90
New
09-A7
Suite 2
6 Roof
1,516
0.034
R-30
R-0.0
0
0
New
02-A26
Suite.2
7 Wall
276
0.065
R-19
R-0.0
90
90
New
09-A7
Suite 3
8 Wall
155
0.065
R-19
R-0.0
270
90
New
_
09-A7
Suite 3
9 Roof
1,516
0.034
R-30
R-0.0
0
0
New
02-A26
Suite 3
10 Wall
276
0.065
R-19
R-0.0
90
90
New
09-A7
Suite 4
11 Wall
155
0.065
R-19
R-0.0
270
90
1 New
09-A7
Suite 4
12 Roof
1,502
0.034
R -30R-0.0
0.72 INFRCI
0
0
New
02-A26
Suite 4
13 Wall
276
0.065
R-19
R-0.0
90
90
New
09-A7
Suite 5
14 Wall
155
0.065
R-19
R-0.01
270
90
New
09-A7
Suite 5
15 Roof
1,502
0.034
R-30
R-0.0
0
0
New
02-A26
Suite 5
16 Wall
276
0.065
R-19
R-0.0
90
90
New
09-A7
Suite 6
17 Wall
155
0.065
R-19
R-0.0
270
90
New
09-A7
Suite 6
18 Roof
1,515
0.034
R-30
R-0.0
0
0
New
02-A26
Suite 6
FWall19
113
0.065
R-19
R-0.0
225
90
New
09-A7
Suite 7
20 Wall
1 287
0.065
R-19
R-0.0
90
90
1 New
09-A7
Suite 7
Morethan or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default 1.1 -factors from
CI�nA�rrle
#
Type
Area U -Fac'
SHGC'
Act.
Am.
Cond.
Stat.
Glazing Type
Location/
Comments
1
Window
Front
W)
38 1.2801116-A
0.72 NFRC
270
New
Double Clear Default(NM)
Suite 1
2
Window
Front
(W)
17 1.280 116-A
0.72 NFRC
270
New
Double Clear Default(NM)
Suite 1
3
Window
Front
(W)
28 1.250 NFRC
0.82 NFRC
270
New
Single Clear Default (NM)
Suite 1
4
Window
Front
W
38 1.280 116-A
0.72 NFRC
270
New
Double Clear Default(NM)
Suite 1
5
Window
Front
W
38 1.280 116-A
0.72 NFRCI
270
New
1 Double Clear Default(NM)
Suite 2
6
Window
Front
(W)
17 1.280 116-A
0.72 NFRC
270
New
Double Clear Default(NM)
Suite 2
7
Window
Front
(W)
28 1.250 NFRC
0.82 NFRC
270
New
Single Clear Default (NM)
Suite 2
8
Window
Front
W
38 1.280 116-A
0.72 NFRC
270
New
Double Clear Default(NM)
Suite 2
9
Window
Front
W
38 1.280 116-A
0.72 NFRC
270
New
Double Clear Default(NM)
Suite 3
10 Window
Front
(W)
17 1.280 116-A
0.72 NFRC
270
New
Double Clear Default(NM)
Suite 3
11 Window
Front
W)
28 1.250 NFRC
0.82 INFRC
2701
New
Single Clear Default (NM)
Suite 3
12
Window
Front
W
38 1.280 116-A
0.72 INFRCI
271DI
New
I Double Clear Default(NM)
Suite 3
13 Window
Front
(W)
38 1.280 116-A
0.72 jN-FRCI
2701
New
I Double Clear Default(NM)
Suite 4
.,�_..._ .. __.__...,,.1e- "o -m, ,-,,,o ,.- - me =a menus: „PPenaix, nrKn Laoeieo value.
2 SHGC Type: 116-8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR SHADING
#
Exterior Shade Type
SHGC
Window
Hgt. Wd.
Overhang Left Fin Right Fin
Len. Hat. LExt.RExt. Dist. Len. H t. Dist. Len.
1
None
0.76
12.3 3.2
4.0
0.1
4.0
4.0
2
None
0.76
2.8 6.0
4.0
0.1
4.0
4.0
3
None
0.76
6.3 4.5
4.0
0.1
4.0
4.0
4
None
0.76
12.3 3.2
4.0
0.1
4.0
4.0
5
None
0.76
12.3 3.2'
4.0
0.1
4.0
4.0
6
None
0.76
2.8 6.0
4.0
0.1
4.0
4.0
7
None
0.76
6.3 4.5
4.0
0.1
4.0
4.0
8
None
0.76 1
12.3 3.2
4.0
0.1
4.0
4.0
9
None
0.76
12.3 3.2
4.0
0.1
4.0
4.0
10
None
0.76
2.8 6.0
4.0
0.1
4.0
4.0
11
None
0.76
6.3 4.5
4.0
0.1
4.0
4.0
12
None
0.76
12.3 3.2
4.0
0.1
4.0
4.0
13
None
0.76
12.3 3.2
4.0
0.1
4.0
4.0
MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
❑The
proposed building contains an enclosed space with floor area greater than 25,000 sq.ft, a telling height greater than 15 feet and a LPD for general lighting of at least 0.5 Wlsq.ft. If this
box Is checked. ENV.4L must hn nIInel -d whnn m,hmiMlnn u..A-. Q... e....._d_.:.._ r___u-___ .______..
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page:6 of 31
CERTIFICATE OF COMPLIANCE ENV -1 -
PROJECT NAME DATE
Washington Park - Shops 4 5/9/2006
Surface
# Type
Area
U -Fac.
Insulation
Cay. Cont.
Act.
Azm.
Tilt
Cond.
Status
Joint Appendix
IV Reference
Location / Comments
21 Wall
241
0.065
R-19
R-0.0
270
90
New
09-A7
Suite 7
22 Roof
1905
0.034
R-30
R-0.0
0
0
New
02-A26
Suite 7
23 Wall
184
0.065
R-19
R-0.0
225
90
New
09-A7
Suite 8
24 Wall
305
0.065
R-19
R-0.0
45
90
New
09-A7
Suite 8
25 Wall
126
0.065
R-19
R-0.0
270 1
90
1 New
09-A7
Suite 8
26 Roof
2,022
0.034
R-30
R-0.0
0
0
New
02-A26
Suite 8
27 Wall
276
0.065
R-19
' R-0.0
45
90
New
09-A7
Suite 9
28 Well
155
0.065
R-19
R-0.0
225
90
New
09-A7
Suite 9
29 Roof_
1,542 0.034
R-30
R-0.0
0
0
New
02-A26
Suite 9
30 Wall
7 685
_ 0.065
R-19
R-0.0
135
90
New
09-A7
Suite 10
31 Wall
276
0.065
R-19
R-0.0
45
90
New
09-A7
Suite 10
32 Wall
155
0.065
1 R-19
R-0.0
225
90
New
09-A7
Suite 10
33 Roof
1,542
0.034
R-30
R-0.0
0
0
New
02-A26
Suite 10
More than or equal to 10,000 sq.ft. of site -built fenestration area must Include a label certificate either Issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from
qt- l d, Tahl- 1 tR-A -dn r-Ainrol- eh -II h- C. -i.. fh- n-- - - .. _ .. ...................... ._ . .. �...iw ..
#.IType
Area U -Fac'
SHGC2
Act.
Azm.
Cond.'
Stat.
Glazing_y a
Location/
Comments
14 Window
Front
(W)
17 1.2801116-A
0.72 NFRC
270
New
Double Clear Default NM
Suite 4
15 Window
Front
(W)
28 1.250 NFRC
0.82 NFRC
270
New
Single Clear Default (NM)
Suite 4
16 Window
Front
(W)
38 1.280 116-A
0.72 NFRC
270
New
Double Clear Default(NM)
Suite 4
17 Window
Front
(W)____
38 1.280 116-A
0.72 NFRC
270
New
Double Clear Default NM
Suite 5
18 Window
Front
W
17 1.280 116-A
0.72 NFRC
270
New
Double Clear Default NM
Suite 5 '
19 Window
Front
W)
281 1.250 NFRC
0.82 NFRC
270
New
Single Clear Default NM
Suite 5
20 Window
Front
W)
381 1.280 116-A
0.72 INFRC
270
New
Double Clear Default NM
Suite 5
21 Window
Front
W
381 1.280 116-A
0.72 NFRC
270
New
Double Clear Default NM
Suite 6
22 Window
Front
W
17 1.2801116-A
0.72 NFRC
270
New
Double Clear Default NM
Suite 6
23 Window
Front
(W)
28 1.250 NFRC
0.82 NFRC
270
New
Single Clear Default (NM)
Suite 6
24 Window
Front
W)
38 1.280 116-A
0.72 NFRC
270
New
Double Clear Default NM
Suite 6
25 Window
Right
SW
21 1.280 116-A
0.72 NFRC
225
New
Double Clear Default NM
Suite 7
26 Window
Right
(SW)
171_T 2-80 116-A
0.72
51
New
I Double Clear Default( M)
Suite 7
1 7M- �'+-^ vo,-m..-m nun iei a s, auie rvl- I uBldali i aaie Iram me mI . Manual Flppena IX, Nht(G L80Blea value.
(2 SHG( Type: 116-e Default Table from Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR SHADING
##
Exterior Shade Type
SHGC
Window
Hgt. Wd.
Overhang Left Fin Right Fin
Len. H t. LExt.RExt. Dist. Len. Hot. Dist. Len. H t.
14
None
0.76
2.8 6.0
4.0
0.1
4.0
4.0
15
None
0.76
6.3 4.5
4.0
0.1
4.0
4.0
16
None
0.76
12.3 3.2
4.0
0.1
4.0
4.0
17
None
0.76
12.3 3.2
4.0
0.1
4.0
4.0
18
1 None
0.76
2.8 6.0
4.0
0.1
4.0
4.0
19
None
0.76
6.3 4.5
4.0
0.1
4.0
4.0
20
None
0.76
12.3 3.2
4.0
0.1
4.0
4.0
21
None
0.76
12.3 3.2
4.0
0.1
4.0
_
4.0
22
None _
0.76
2.8 6.0
4.0
0.1
4.0
4.0
23
None
0.76
6.3 4.5
4.0
0.1
4.0
4.0
24
None
0.76
12.3 3.2
4.0
0.1
4.0
4.0
25
None
0.76
12.3 1.7
7.0
0.1
7.0
7.0
26
None
0.76
2.8 6.0
7.0
0.1
7.0
7.0
MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
LJ... proposea ounaing concams an enclosea space wnn floor area greater than 25,000 sq.ft, a ceiling height greater than 15 feet and a LPD for general lighting of at least 0.5 W/sq.ft. If this
box Is checked, ENVAC must be filled out when submitting under the Prescriptive Compliance Approach.
nergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Paoe:7 of 31 1
ICERTIFICATE OF COMPLIANCE ENV -1 -CI
PROJECT NAME DATE
Washington Park - Shops 4 5/9/2006
OPAQUE SURFACES
Surface
# Type Area U -Fac.
Insulation
Cay. Cont.
Act.
Am. Tilt
Cond:
Status
Joint Appendix
IV Reference Location / Comments
Act.
Azm.
Cond.
Stat.
Glazing Type
Location/
Comments
27 Window
Right
(�
28 1.250 NFRC
0.82 NFRC
225
New
I Single Clear Default NM
Suite 7
28 Window
Right
(SW)
21. 1.280 116-A
0.72 NFRC
225
New
Double Clear Default(NM)
Suite 7
29 Window
Right
(SW)
21 1.280 116-A
0.72 NFRC
225
New
Double Clear Default(NM)
Suite 7
30 Window
Right
(SW)
17 1.280 1165A
0.72 NFRC
225
New
Double Clear Default(NM)
Suite 7
31 Window
Right
SW
28 1.250 NFRC
0.82 NFRC
225
New
Single Clear Default NM
Suite 7
32 Window
Right
(SW)
2 1.280 116-A
0.72 NFRC
225
New
Double Clear Default(NM)
Suite 7
33 Window
Front
(W)
38 1.280 116 -Al
0.72 NFRC
270
New
Double Clear Default(NM)
Suite 7
34 Window
Front
W
17 1.280 116-A
0.72 NFRC
270
New
Double Clear Default(NM)
Suite 7
35 Window
Front
W
28 1.250 NFRC
0.82 NFRC
270
New
Sin le Clear Default (NM)
Suite 7
36 Window
Front
(W)
38 1.280 116-A
0.72 NFRC
270
New
Double Clear Default(NM)
Suite 7
37 Window
Front
(W)
21 1.280 116-A
0.72 NFRCI
270
i� More than or equal to 10,000 sq.ft. of site -built fenestration amust include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default 1.1 -factors from
I I s�� 2,M. T..:- t.a_e a n r-.ra.. u w r.. .:_..rea_
# Ty -pe
Area U -Fac'
SHGC2
Act.
Azm.
Cond.
Stat.
Glazing Type
Location/
Comments
27 Window
Right
(�
28 1.250 NFRC
0.82 NFRC
225
New
I Single Clear Default NM
Suite 7
28 Window
Right
(SW)
21. 1.280 116-A
0.72 NFRC
225
New
Double Clear Default(NM)
Suite 7
29 Window
Right
(SW)
21 1.280 116-A
0.72 NFRC
225
New
Double Clear Default(NM)
Suite 7
30 Window
Right
(SW)
17 1.280 1165A
0.72 NFRC
225
New
Double Clear Default(NM)
Suite 7
31 Window
Right
SW
28 1.250 NFRC
0.82 NFRC
225
New
Single Clear Default NM
Suite 7
32 Window
Right
(SW)
2 1.280 116-A
0.72 NFRC
225
New
Double Clear Default(NM)
Suite 7
33 Window
Front
(W)
38 1.280 116 -Al
0.72 NFRC
270
New
Double Clear Default(NM)
Suite 7
34 Window
Front
W
17 1.280 116-A
0.72 NFRC
270
New
Double Clear Default(NM)
Suite 7
35 Window
Front
W
28 1.250 NFRC
0.82 NFRC
270
New
Sin le Clear Default (NM)
Suite 7
36 Window
Front
(W)
38 1.280 116-A
0.72 NFRC
270
New
Double Clear Default(NM)
Suite 7
37 Window
Front
(W)
21 1.280 116-A
0.72 NFRCI
270
New
Double Clear Default(NM)
Suite 8
38 Window
Front
W
17 1.280 116-A
0.72 INFRCI
2701
New
I Double Clear Default(NM)
Suite 8
39 Window
Front
(W)
28 1.250 NFRC
0.82 INFRCI
2701
New
I Single Clear Default(NM)
Suite 8
at„ , e...e ., �:n mo n..:n menu.: r.ypenmx, rvrrti. .acre... value.
2 SHGC Type: 116-8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR SHADING
##
Exterior Shade Type
SHGCI
Window
. Hgt. Wd.
Overhang
Len. Hgt. LExt.RExt.
Left Fin Right Fin
Dist. Len. H t. Dist. Len. H t.
27
None
0.76
6.3 4.5
7.0
0.1
7.0
7.0
28
None
0.76
12.3 1.7
7.0
0.1
7.0
7.0
29
None
0.76
12.3 1.7
7.0
0.1
7.0
7.0
30
None
0.76
2.8 6.0
7.0
0.1
7.0
7.0
31
None
0.76
6.3 4.5
7.0
0.1
7.0
7.0
32
None
0.76
12.3 1.7
7.0
0.1
7.0
7.0
33
None
0.76 1
12.3 3.2
4.0
0.1
4.0
4.0
34
None
0.76
2.8 6.0
4.0
0.1
4.0
4.0
35
None
0.76
6.3 4.5
4.0
0.1
4.0
4.0
36
None
0.76
12.3 3.2
4.0
0.1
4.0
4.0
37
1 None
0.76
12.3 1.7
7.0
0.1
7.0
7.0
_
38
None
0.76
2.8 6.0
7.0
0.1
7.0
7.0
_
39
None
0.76
6.3 4.5
7.0
0.1
7.0
7.0
MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
❑The
proposed building contains an enclosed space with Floor area greater than 25,000 sq.ft, a ceiling height greater than 15 feet and a LPD for general lighting of at least 0.5 W/sq.f . If this
box Is checked. ENVd.0 must he filled ent -he..
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page:8 of 31
ICERTIFICA
PROJECT NAME
Washil
RF,
OF COMPLIANCE
i Park - Shops 4
ENV -1 -C
DATE
5/9/2006
# Surface Insulation Act. Cond: Joint Appendix
Type Area U -Fac. Cay. Cont. Azm. Tilt Status IV Reference Location / Comments
• N F e R IN.- F.icnnn ena.ew D.,.........w,
More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default 11 -factors from
_.. _._.."''-• . 'Center
.Gla.....,.... NFRC
.b ed IV, .I.us m r.yyenu,e, nrn.. �ausieu varve.
2 SHGC Type: 116-8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR SHADING
Act. Cond.
Location/
# Type
#
40
Area U -Fac'
SHGC2
Azm.
Stat.
Glazing a
Comments
40 Window
Front
W)
21 1.280 116-A
0.72 NFRC
270
New
_y
Double Clear Default NM
Suite 8
41 Window
Front
W
21 1.280 116-A
0.72 NFRC
270
New
Double Clear Default(NM)
Suite 8
42 Window
Front
(W)
17 1.280 116-A
0.72 NFRC
270
New
Double Clear Default NM
Suite 8
43 Window
Front
W
28 1.250 NFRC
0.82 NFRC
270
New
Single Clear Default NM
Suite 8
44 Window
Front
W
_ 2, 1.280 116-A
0.72 NFRC
270
New
Double Clear Default NM
Suite 8
45 Window
Front
(W)
21 1.280 116-A
0.72 NFRC
270
New
Double Clear Default(NM)
Suite 8
46 Window
Front
W)
17 1.2801116-A
-01
0.72 NFRC
270
New
Double Clear Default NM
Suite 8
47 Window
Front
W
28 172-5 NFRC
0.82 NFRC
270
New
I Sin 'le Clear Default NM
Suite 8
48 Window
Front
W
21 1.2801116-A
0.72 NFRC
270
New
Double Clear Default NM
Suite 8
49 Window
Right
(SW)
38 1.280 116-A
0.72 INFRCI
225
New
I Double Clear Default(NM)
Suite 9
50 Window
Right SW
17 1.280 116-A
0.72 NFRC
225
New
Double Clear Default NM
Suite 9
51 Window
Right28
1.250 NFRC
0.82 NFRC
225
New
Single Clear Default NM
Suite 9
52 Window
Right
(SW)
38 1.280 116-A
. _
0.72 NFRC
225
New
Double Clear Default NM
Suite 9
_.. _._.."''-• . 'Center
.Gla.....,.... NFRC
.b ed IV, .I.us m r.yyenu,e, nrn.. �ausieu varve.
2 SHGC Type: 116-8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR SHADING
#
40
. Exterior Shade Type
None
SHGC
0.76
Window
Hgt. Wd.
12.3 1.7
Overhang Left Fin Right Fin
Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. Hgt.
7.0 0.1 7.0 7.0
41
None
0.76
12.3 1.7
7.0
0.1
7.0
7.0
42
None
0.76
2.8 6.0
7.0
0.1 '
7.0
7.0
43
None
0.76
6.3 4.5
7.0
0.1
7.0
7.0
44
None
0.76
12.3 1.7
7.0
0.1
7.0
7.0
45
None
0.76
12.3 1.7
7.0
0.1
7.0
7.0
46
None
0.76
2.8 6.0
7.0
0.1
7.0
7.0
47
None
0.76
6.3 4.5
7.0
0.1
7.0
7.0
48
None
0.76
12.3 1.7
7.0
0.1
7.0
7.0
49
None
1 0.76
12.3 3.2
1 .0
0.1
4.0
4.0
50
None
0.76
2.8 6.0
4.0
0.1
4.0
4.0
51
None
0.76
6.3 4.5
4.0
0.1
4.0
4.0
52
1 None
1 0.76
12.3 3.2
4.0
0.1
4.0
4.0
MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
1:1The
proposed building contains an enclosed space with floor area greater than 25,000 sq.ft, a ceiling height
box Is checked. ENV -d1] muse ho nu -n -f u,h-.,
greater than 15 feet and a LPD for general lighting of at least 0.5 W1sq.fL If this
Run Initiation Time: 05/09/06 16:15:26r Run Code: 1147216526
i.1 by EnergySoft User Number: by EnergySoft User Number: Job Number: 06-002 Paoe:9 of 31
CERTIFICATE OF COMPLIANCE ENV-1-C�
PROJECT NAME DATE
Washington Park -Shops 4 5/9/2006
Surface I Insulation I Act. I Cond. I Joint Appendix
# Type Area U -Fac. Cay. Cont. Azm. Tilt Status IV Reference Location / Comments
FENESTRATION SURFACES
More than or equal to 10.000 sq.h. of site -built fenestration area must include a label certificate either Issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from
# Type
53 Window
Rear
SE
Area U -Fac'
21 1.2801116-A
SHGC2
0.72 NFRC
Act.
Azm.
135
Cond.
Stat.
New
Glazing Type
Double Clear Default NM
Location/
Comments
Suite 10
54 Window
Rear
(SE)
76 1.280 116-A
0.72 NFRC
135
New
Double Clear Default(NM)
Suite 10
55 Window
Rear
SE
21 1.280 116-A
0.72 NFRC
135
New
Double Clear Default NM
Suite 10
56 Window
Right
SW
38 1.280 116 -Al
0.72 NFRC
225
New
Double Clear Default NM
Suite 10
57 Window
Right
SW
17 1.280 116-A
0.72 NFRC
225
New
Double Clear Default NM
Suite 10
58 Window
Right
(SW)
28 1.250 NFRC
0.82 NFRCI
225
New
Single Clear Default (NM)
Suite 10
59 Window
Right
(SW)
38 1.280 116 A
0.72 NFRC
225
New
Double Clear Default(NM._
Suite 10
MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
11The proposed building contains an enclosed space with floor area greater than 25,000 sq.ft, a telling height greater than 15 feet and a LPD for general lighting of at least 0.5 W/sq.fL If this
_____
box Is checked- ENVd.0 rnuar hn Bllnrl # h.. -„h..Jeb.......a.,-- e---_.,.._ ..___..---- ------
.. : 116-8 Default Table from __._ .mmin, nrn
. _... _._.."' . __... ... ..... .............a ...,,,, .,.o ,,..,., manuur.yy; Lautl�Co value.
2 SHGC Typeom Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR SHADING
Run
## Exterior Shade Type
53 . None
SHGC
0.76
Window
Hgt. Wd.
12.3 1.7
Overhang Left Fin Right Fin
Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t.
4.0 0.1 4.0 4.0
54 None
0.76
12.3 6.0
4.0 0.1 4.0
4.0
55 None
0.76
.12.3 1.7
4.0 0.1 4.0
4.0
56 None
0.76
12.3 3.2
4.0 0.1 4.0
4.0
57 1 None
0.76
2.8 6.0
4.0 0.1 4.0
4.0
58 None
0.76
6.3 4.5
4.0 0.1 4.0
4.0
59 None
0.76
12.3 3.2
4.0 0.1 4.0
4.0
MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
11The proposed building contains an enclosed space with floor area greater than 25,000 sq.ft, a telling height greater than 15 feet and a LPD for general lighting of at least 0.5 W/sq.fL If this
_____
box Is checked- ENVd.0 rnuar hn Bllnrl # h.. -„h..Jeb.......a.,-- e---_.,.._ ..___..---- ------
Run Initiation Time: 05/09/06 16:15:26 Run Code: 1147216526
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page: 10 of 31
ICERTIFICATE OF COMPLIANCE MECH-1-C I
PROJECT NAME DATE
Washington Park - Shops 4 5/9/2006
Designer:
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to
check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the
equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential
ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent
selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work
appropriately.
Building Departments:
SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a
building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for
Code Compliance. I r
In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation
rartif—tat nrl n rofinn onri ,n nfnnonne i..r........N....... ..I +ti.. .
STATEMENT OF COMPLIANCE
® MECH-2-A: Ventilation System Acceptance Document
-Variable Air Volume Systems Outdoor Air Acceptance
$y the General
-Constant Air Volume Systems Outdoor Air Acceptance'Coritractor
RTU -1 thru RTU -10 -
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit.
MECH-3-A: Packaged HVAC Systems Acceptance Document RTU -1 thru RTU -10
Equipment requiring acceptance testing
By the General
Contractor
Test required on all New systems both New Construction and Retrofit
N, MECH-4-A: Air -Side Economizer Acceptance Document
RTU-8Equipment requiring acceptance testing
By the General
Contractor
Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the
commission do not require equipment testing but do require construction inspection. - ,•
�j MECH-5-A: Air Distribution Acceptance Document RTU -1 thru RTU -10
Equipment requiring acceptance testing
By the General
Contractor
-
This test required If the unit serves 5,000112 of space or less and 25% or more of the ducts are in nonconditioned or semiconditioned space like an
attic. New systems that meet the above requirements. Retroril systems that meet the above requirements and either extend ducts, replace ducts or
replace the packaged unit.
® MECH-6-A: Demand Control Ventilation Acceptance Document
RTU -8
By the General
Equipment requiring acceptance testing
• r
Contractor
All new DCV controls installed on new or existing packaged systems must be tested.•-
❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document
Equipment requiring acceptance testing
All new VAV fan volume controls installed on new or existing systems must be tested
❑ MECH-8-A:-Hydronic System Control Acceptance Document
-Variable Flow Controls Applies to chilled and hof watersystems.
-Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header.
-Supply Water Temperature Reset Controls
Applies to new constant flow chilled and hof water systems that have a design capacity greater than or equal to 500,000 Btu/hr.
-Water-loop Heat Pump Controls
Applies to all new waterfoop heat pump systems where the combined loop pumps are greater than 5 hp.
-Variable Frequency Controls Applies to all new distribution pumps on new variable now chilled, hydronic heat pump
or condenser water systems where the pumps motors are greater than 5 hp.
Equipment requiring acceptance testing
EnergyPro 4.1 by Energysoft User Number: 3358 Job Number: 06-002 Page:11 of 31
r
AIR SYSTEM REQUIREMENTS Part 1 of 2 - MECH-2-C
PROJECT NAME - DATE
Washington Park - Shops 4 5/9/2006
SYSTEM FEATURES
ITEM OR SYSTEM TAGS)
Number of Systems _n
AIR SYSTEMS, Central or Single Zone
RTU -1
RTU -2
RTU -3
112(a)
13.0 SEER / 13.0 EER
13.0 SEER / 13.0 EER
T-24
MANDATORY MEASURES Section r Reference on Plans or Specification t
Heating Equipment Efficiency
Cooling Equipment Efficiency
Heat Pump Thermostat
Furnace Controls
Natural Ventilation
Minimum Ventilation
VAV Minimum Position Control
Demand Control Ventilation
Time Control
Setback and Setup Control ,
Outdoor Damper Control
Isolation Zones
Pipe Insulation
Duct Insulation
112(a)
7.70 HSPF
7.70 HSPF
7.70 HSPF
112(a)
13.0 SEER / 13.0 EER
13.0 SEER / 13.0 EER
13.0 SEER / 13.0 EER
112(b)
Yes
Yes-
Yes
112(c), 115(a)
n/a
n/a
r n/a
121(b) •
No
No
No
121 (b)472
cfm
517 cfm
517 cfm
121 c
No
No
No
121(c)
No
No
No
1210, 122(e)
Programmable Switch
Programmable Switch
Pro rammable Switch
122(e)
Heating & Cooling Required
Heating & Cooling Required
Heating & Cooling Required
122(f)
Auto
Auto
Auto
122(g)
n/a
n/a
n/a
123
124
R-8.0
R-8.0
R-8.0
PRESCRIPTIVE MEASURES
Calculated Heating Capacity x 1.43 2
Proposed Heating Capacity 2
Calculated Sensible Cooling Capacity x 1.212
Proposed Sensible Cooling Capacity 2
Fan Control
DP Sensor Location
Supply Pressure Reset (DDC only)
Simultaneous Heat/Cool
Economizer
Heating Air Supply Reset
Cooling Air Supply Reset
Duct Sealing for Prescriptive Compliance3
144 a & b)
n/a
n/a
• n/a
144 a & b
34,352 btuh
34,352 btuh
34,352 btuh
144 a & b
n/a. _
n/a
n/a
144 a & b
52,051 btuh
52,775 btuh
52,775 btuh
144 c
Constant Volume
Constant Volume
Constant Volume
144 (c
144(c)
'Yes
Yes "
Yes
144 d
No
No
No
144 a
No Economizer ` .
No Economizer
No Economizer
144 f
Constant Temp
Constant Tem
Constant Tem
144(f)
'Constant Temp
Constant Temp
Constant Temp
144 k
No
No
No
1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the
required features are documented. If a requirement is not applicable, put "N/A" in the column.
2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1.
3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance,
see PERF -1 for performance method duct sealing requirements.
o 4.1 by EnergySoft User Number: 3358
3
Job Number: 06-002
- f ,
e a
1147216526
Page:12 of 31
e
JAIR SYSTEM REQUIREMENTS Part 1 of 2 ' MECH-2-C
PROJECT NAME DATE ,
Washington Park - Shops 4 ,5/9/2006
SYSTEM FEATURES
ITEM OR SYSTEM TAG(S)
Number of Systems
AIR SYSTEMS, Central or Single Zorie
RTU -4
RTU -5
RTU -6
112(a)
13.0 SEER / 13.0 EER
•-13.0 SEER / 13.0 EER
T-24
MANDATORY MEASURES Section , ' - Reference on Plans or Specification 1 .
Heating Equipment Efficiency
Cooling Equipment Efficiency
Heat Pump Thermostat
Furnace Controls
Natural Ventilation
Minimum Ventilation
VAV Minimum Position Control
Demand Control Ventilation
Time Control
Setback and Setup Control ,
Outdoor Damper Control
Isolation Zones
Pipe Insulation
Duct Insulation
PRESCRIPTIVE MEASURES
Calculated Heating Capacity x 1.43 2
Proposed Heating Capacity 2
Calculated Sensible Cooling Capacity x 1.212
Proposed Sensible Cooling Capacity 2
Fan Control
DP Sensor Location
Supply Pressure Reset (DDC only)
Simultaneous Heat/Cool
Economizer J•
Heating Air Supply Reset
Cooling Air Supply Reset
Duct Sealing for Prescriptive Compliance
112(a)
7.70 HSPF
7.70 HSPF
7.70 HSPF
112(a)
13.0 SEER / 13.0 EER
•-13.0 SEER / 13.0 EER
13.0 SEER / 13.0 EER
112(b)
Yes
Yes
Yes
112(c), 115(a)
n/a
n/a
n/a
121(b) '
No
No
No
121 b
512 cfm
512 cfm
516 cfm
1210
No
No
No,
121(c)
No
No
No
121(c), 1220
Programmable Switch .
Programmable Switch
Programmable Switch
122(e)
r
Heating & Cooling Required
'Heating & Cooling Required
Heating & Cooling Required
122
Auto
Auto
Auto
122(g)
n/a
n/a
n/a
123
124
R-8.0 .+
R-8.0
R-8.0
144 a & b
n/a
n/a
n/a
144 (a & b)
34,352 btuh
34,352 btuh
34,352 btuh
144 (a & b)
n/a
n/a
n/a
144 (a& b
52,698 btuh
52,698 btuh
52,770 btuh
144 c
Constant Volume
Constant Volume
Constant Volume
144 c)
"
144 c
Yes
Yes
Yes
144 d
No
No
No
144 a
No Economizer `.
No Economizer
No Economizer
144 (f)
Constant Temp
Constant Temp
Constant Temp
144 (f)
Constant Temp
Constant Temp
Constant Temp
144 k
No
No
No
1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the
required features are documented. If a requirement is not applicable, put "N/A" in the column.
2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1.
3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance,
see PERF -1 for performance method duct sealing requirements.
NOTES.,TO FIELD - For Buildinci Department Use Only
� u
r; . >^, :. :t ..^a::-:` .:. , -r. :v�: ,... a x c ::`\ s,...' fie, �E � '�• � a, U.. a, -'„ r �' i k j:
Run Initiation Time: 05/09/06 16:15:26 Run Code: 1147216526
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page: 13 of 31
t
r. - •
JAIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C
PROJECT NAME DATE
Washington Park - Shops 4 5/9/2006
SYSTEM FEATURES
ITEM OR SYSTEM TAG(S) +
Number of Systems
AIR SYSTEMS, Central or Single Zone -
7.70 HSPF
RTU -7•
RTU -8 RTU -9'
13.0 SEER / 13.0 EER
112(b) Yes "
T-24
MANDATORY MEASURES Section Reference on Plans or Specification
Heating Equipment Efficiency T
Cooling Equipment Efficiency,
Heat Pump Thermostat
Furnace Controls
Natural Ventilation
Minimum Ventilation
VAV Minimum Position Control
Demand Control Ventilation
Time Control
Setback and Setup Control
Outdoor Damper Control
Isolation Zones
Pipe Insulation
Duct Insulation
PRESCRIPTIVE MEASURES
Calculated Heating Capacity x 1.43 2
Proposed Heating Capacity 2
Calculated Sensible Cooling Capacity x 1.212
Proposed Sensible Cooling Capacity 2
Fan Control
DP Sensor Location
Supply Pressure Reset (DDC only)
Simultaneous Heat/Cool
Economizer
Heating Air Supply Reset
Cooling Air Supply Reset
Duct Sealing for Prescriptive Compliam e3-
112(a) 3.40 COP
3.30 COP
7.70 HSPF
112(a) 10.5 EER
10.3 EER
13.0 SEER / 13.0 EER
112(b) Yes "
Yes
Yes -
112 c , 115(a) n/a
,- ' n/a .
n/a
121(b) No
' No
No
121 b 649 cfm
689 cfm
526 cfm
121 c No
No
No
121(c). No
Yes
No
_L21 L_(c 122(e) Programmable Switch
Pro rammable Switch
Programmable Switch
122(e) Heating & Cooling Required)>Heating
&Cooling Required
Heating & Cooling Required
1220 Auto
Auto
Auto
122 n/a
n/a
n/a
123
Constant Temp
Constant Temp
124 R-8.0
r R-8.0
R-8.0
144 a &b)
n/a
n/a
n/a
144 a & b
43,096 btuh -
53,089 btuh
34,352 btuh
144 a & b
n/a
n/a
n/a
144 a & b
65,462 btuh
76,680 btuh
53,149 btuh
144 c
Constant Volume
Constant Volume
Constant Volume
144 c
144 c
Yes
Yes
Yes
144 d
No
No r
No
144 (e '
No Economizer
Fixed Temp Non-Inte
No Economizer
144
Constant Temp
Constant Temp
Constant Tem
144 (f)
Constant Temp
Constant Temp
Constant Temp
144 k
No
No
No
1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the
required features are documented. If a requirement is not applicable, put "N/A" in the column.
2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1.
3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance,
see PERF -1 for performance method duct sealing requirements.
[AIR SYSTEM REQUIREMENTS Part 1 of,2 MECH-2-C .
PROJECT NAME - - DATE t
Washington Park -Shops 4' 5/9/2006
SYSTEM FEATURES
AIR SYSTEMS, Central or Single Zone
ITEM OR SYSTEM TAG(S) - - RTU -10
Number of Systems 1
T-24 -
MANDATORY MEASURES Section , . Reference on Plans or Specification
Heating Equipment Efficiency
Cooling Equipment Efficiency
Heat Pump Thermostat
Furnace Controls
Natural Ventilation
Minimum Ventilation
VAV Minimum Position Control
Demand Control Ventilation
Time Control
Setback and Setup Control
Outdoor Damper Control
Isolation Zones
Pipe Insulation
Duct Insulation
PRESCRIPTIVE MEASURES
Calculated Heating Capacity x 1.43 2
Proposed Heating Capacity 2 '
Calculated Sensible Cooling Capacity x.1.212
Proposed Sensible Cooling Capacity 2
Fan Control
DP Sensor Location
Supply Pressure Reset (DDC only)
Simultaneous Heat/Cool
Economizer
Heating Air Supply Reset
Cooling Air Supply Reset
Duct Sealing for Prescriptive Compliance
112(a) '
7.70 HSPF
112(a)
13.0 SEER / 13.0 EER '
112(b)
Yes "
112 c), 115(a)
n/a
121(b)
No
121(b)
526 cfm
121 c -.
No "
121(c)
No
121 c 122(e)
Programmable Switch
122(e)
-Heating & Cooling Required
122
r
Auto
122(g)
n/a
123
'
124
R-8.0
144 a & b
n/a
144 a & b
34,352 btuh
144-(a & b)
n/a
144 (a & b)_
53,398 btuh
144 U
Constant Volume
144 c
144 c
Yes
144 d
No
144 a
No Economizer
144 () .
Constant Temp
144 (f)
Constant Temp
144 k }
No
i
1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the
required features are documented. If a requirement is not applicable, put "N/A" in the column.
2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1.
3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft;. Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance,
see PERFA for performance method duct sealing requirements. -
INCITES TO FIELD - For Building a Use Only
4:'
Kun Initiation f Ime: u5/c
4.1 by EnergySoft User Number: 3358
r
Job Number: 06-002
WATER SIDE SYSTEM REQUIREMENTS Part 2 of 2 MECH-2-C
PROJECT NAME DATE
Washington Park - Shops 4 5/9/2006
SYSTEM FEATURES
2 WATER SIDE SYSTEMS: Chillers, Towers, Boilers, H dronic Loops
ITEM OR SYSTEM TAG(S)
Number of Systems
. . T-24
MANDATORY MEASURES Section Reference on Plans or Specification'
Equipment Efficiency 11 12(a) -
Pipe Insulation 123
PRESCRIPTIVE MEASURES " •'
Calculated Capacity
144 (a& b)
Proposed Capacity
144 (a & b),
Tower Fan Controls
144 h
Tower Flow Controls
144 h
Variable Flow System Design
144 0)
Chiller and Boiler Isolation
144 '
CHW and HHW Reset Controls
144
WLHP Isolation Valves
144 '
VSD on CHW, CW & WLHP Pumps > 5
HP
144
DP Sensor Location
1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph
number where the required features are documented. If a requirement is not applicable, put "N/A" in the column.
2: Water side systems include wet side system using other liquids such as glycol or brine:`.: F
Service Hot Water, Pool Heating
ITEM OR SYSTEM TAG(S) DHW Heater
Number of Systems 8 -
.MANDATORY MEASURES Reference on Plans or Specification'
Water Heater Certification
113 (a)'
Water Heater Efficiency
113 b
Service Water Heating Installation
113 (c)
Pool and Spa Efficiency and Control
114 a
Pool and Spa Installation
114 b
( Pool Heater - No Pilot Light
115 (c)
Spa Heater - No Pilot Light
115(d)
1: For each water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the, reference to sheet number and/or specification section and '
paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" ins the column. .
cZ4 dMa t� a„ .��'S . ;� :• �',;�"' R +. �.� -: Sj - .a r6,. . ,�,, m: ;ynz5 �,,.`sr,q
> >.� � - � c � +, ? a � ..H a F i•.,. p r•, a, w e ��a '� Q�rt�`"�0�°'"�i` � '•`0�f^"�" � �°i 4 �
,� :'�, - r B :� F # ,.< i �..+•""- y �;. .-"fin..+: e-#.:'' x, 4*+'i°a'.vw.'�'
� ye
s, , '�z c a '.> f r. `.%'nc 0 ? r z'L -�+, ,TC f2-."��„y+4er•.w,�»•,^°�,''�' `»-'�'r+ja +"'�r�r "rrw. `'{'c,..�'" 'iK'
Run Initiation Time: 05/09/06 16:15:26 Run Code: 1147216526
EnergyPro 4.1 by Energysoft User Number: 3358 Job Number: 06-002 Page:16 of 31
MECHANICAL VENTILATION MECH-3-0
PROJECT NAME
Washinaton Park - S
DATE
PRESCRIPTIVE REHEAT
LIMITATION Section 144(d))
MECHANICAL VENTILATION Section 121(b)21
AREA BASIS
OCCUPANCY BASIS
VAV MINIMUM
A
B
C
D
E
F
G
H
I
J
K
L
M
N
ZONE/SYSTEM
D�
TAa
��
N
m n
.�(DT
c'3
p`P3
xDo
0; -A
Z
vo
ov
fDo
mmT
0'3
03
x�o
Tm3
Gam
oXtj p
�°<
m p
�o.m
D�
N o
�"
�y�
3C0
za
0
moo
3x
�a
°c 3
o3d
0
=0
3�
m�
a�
0
'3
D
lu
y
D
Suite 1
1,385
0.22.
305
31.5
-15.0
472
472
472
RTU -1
Total
472
472
Suite 2
1,516
0.22
334
34.5
15.0
517
517
517
RTU -2
Total
517
517
Suite 3
1,51E
0.221
334
34.5
15.0
517
517
517
RTU -3
Total
517
517
Suite 4
1,502
0.22
330
34.1
.15.0
512
512
512
RTU -4
ITotal
1 512
512
Suite 5
1,502
0.221
330
34.1
15.0
512
512
512
RTU -5
Total
512
512
Suite 6
1,51E
0.22
333
34.4
15.0
516
516
516
RTU -6
Total
516
516
Suite 7
1,905
0.221
419
43.31
15.0
649
649
649
RTU -7
Total
649
649
Suite 8
2,022
0.22
445
46.0
15.0
689
689
689
RTU -8
Total
689
689
Suite 9
1,542
0.22
339
35.0
15.0
526
526
526
RTU -9
Total
526
526
'
Suite 10
1,542
0.22
339
35.0
15.0
526
526
526
RTU -10
Total
526
526
Minimurn venfilawn rate per 3jp l on 121. Table 121-A
Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load for egress o�Lrposes fors aces without fixed seating.
H Re uired Ventilation Air( V.A.) is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS (column D or G).
I Must be greater than or equal to H, or use Transfer Air (column Nl to make up the difference.
J Design fan supply c1m (Fan CFM) x 30%; or
K Condition area R, sq.) x 04 cfm/R. sq; or
L Maximum of Columns H, J. K. or 300 cfm
M I This must be less than or equal to Column L and greater that or equal to the sum of Columns H + N.
N Transfer air must be provided where the Required Ventilation Air (column H) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or
equal to the difference between the Required Ventilation Air (column H) and the Design Minimum Air (column M), column H - M.
Ener Pro 4.1 by EneTySoft User Number: 3358 Job Number: 06-002 Page: 17 of 31
MECHANICAL EQUIPMENT DETAILS
Part 1 of 2 MECH-5-C
PROJECT NAME
Washington Park - Shops 4
DATE 5/9/2006
CHILLER AND TOWER SUMMARY
System Type
Distribution Type
Efficiency
Tons
PUMPS
Condition
Status
Equipment Name
Equipment Type
Qty.
Tot.
Qty
GPM
BHP
Motor
Eff..
Drive
Eff.
Pump
Control
n/a
n/a
MULTI -FAMILY CENTRAL WATER HEATING DETAILS
Hot Water P mp
Hot Water Piping Length (ft)
Control
#
HP
T pe
In Plenum
Outside
Buried
Add 1/2"
Insulation
1DHW BOILER SUMMARY
Energy
Factor
or RE
Standby
Loss or
Pilot
TANK INSUL.
System Name
System Type
Distribution Type
Qty
Rated
Input
Vol.
(Gals.)
Condition
Status
Ext.
R -Val.
CHRONOMITE S-30 LP
Instant Elec
No Pipe Insulation
8
9,429
0
New
0.98
n/a
n/a
MULTI -FAMILY CENTRAL WATER HEATING DETAILS
Hot Water P mp
Hot Water Piping Length (ft)
Control
#
HP
T pe
In Plenum
Outside
Buried
Add 1/2"
Insulation
CENTRAL SYSTEM RATINGS
HEATING
COOLING
System Name
System Type
output
Aux.
kW
Eff.
Output
Efficiencv
Condition
Status
I._Economizer Type
CARRIER 50HJ0006
Packaged DX
8
55,000
0.0
7.70 HSPF
63,800
13.0 SEER / 13.0 EER
New
No Economizer
CARRIER 50HJ0007
Packaged DX
1
69,000
0.0
3.40 COP
76,000
10.5 EER
New
No Economizer
CARRIER 50HJ0008
Packaged DX
1
85,000
0.
3.30 COP
91,300
10.3 EER
New
Fixed Temp (Non-Inte
CENTRAL SYSTEM FAN SUMMARY
SUPPLY FAN
RETURN
FA
System Name
Fan Type
Motor Location
CFM
BHP
Motor
Eff.
Drive
Eff.
CFM
BHP
Motor
Eff.
Drive
Eff.
CARRIER 50HJ0006
Constant Volume
Draw -Through
2,000
0.40
66.0%
97.0%
none
CARRIER 50HJQ007
Constant Volume
Draw -Through
2,400
0.70
76.0%
97.0%
none
CARRIER 50HJ0008
Constant Volume
Draw -Through
3,000
0.70
76.0%
97.0%
none
Run Initiation Time: 05/09/06 16:15:26 Run Code: 1147216526
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page: 18 of 31
ENVELOPE MANDATORY MEASURES
PROJECT NAME .
Washington Park - Shops 4
ENV -MM
DATE
5/9/2006
DESCRIPTION
Designer
Enforcement
0 §118(a) Installed Insulating Material shall have been certified by the manufacturer to comply
with the California Quality Standards for insulating material, Title 20, Chapter 4, Article
3
F §118(c) All Insulating Materials shall be Installed in compliance with the flame spread rating
and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2.
§117(a) All Exterior Joints and openings in the building that are observable sources of air
leakage shall be caulked, gasketed, weatherstripped or otherwise sealed.
FXJ§ 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit
and the building, and shall be weatherstripped (except for unframed glass doors and
fire doors).
RI §'l 16(a)l Manufactured Doors and Windows installed shall have air infiltration rates not
exceeding those shown in Table Number 1-E. of the Standards. Manufactured
fenestration products must,be labeled for U -value according to NFRC procedures.
X❑ §118(e) Demising Walls in Nonresidential Buildings: 4 '
The opaque portions of framed demising walls in nonresidential buildings shall have
Insulation with an installed R -value of no less than R-11 between framing members.
EnergyPro By EnergySoft User Number: User Job Number: 06-002 Page:19 of 31
ti
IECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MI
PROJECT NAME DATE
Washington Park - Shops 4 5/9/2006
DESCRIPTION
Designer
Enforcement
Equipment and Systems Efficiencies
❑X §111 Any appliance for which there is a California standard established in the .
Appliance Efficiency Regulations will comply with the applicable standard.
7 § 115(a) Fan type central furnaces shall not have a pilot light.
F§ 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees,
Fahrenheit, or within HVAC equipment, shall be insulated In accordance with '
Standards Section 123.
X❑ § 124 Air handling duct systems shall be installed and insulated in compliance with
Sections 601, 603 and 604 of the Uniform Mechanical Code.
Controls '
§ 122(e) Each space conditioning system shall be installed with one of the following:
X❑ §,122(e)1A Each space conditioning system serving building types such as offices and'
manufacturing facilities (and all others not explicitly exempt from the
requirements of Section 112 (d)) shall be installed with an automatic time switch
with an accessible manual override that allows operation of the system during
off -hours for up to 4 hours. The time switch shall be capable of programming
different schedules for weekdays and weekends and have program backup
capabilities that prevent the loss of the device's program and time setting for at
least 10 hours if power is interrupted; or
FX]§ 122(e)1B An occupancy sensor to control the operating period of the system; or
0 § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of
the system.
X❑ § 122(e)2 Each space conditioning system shall be Installed with controls that temporarily
restart and temporarily operate the system as required to maintain a setback
heating and/or a setup cooling thermostat setpoint.
❑ § 122(g) Each space conditioning system serving multiple zones with a combined
conditioned floor area more than 25,000 square feet shall be provided with
Isolation zones. Each zone: shall not exceed 25,000 square feet; shall be
provided with isolation devices, such as valves or dampers, that allow the supply
of heating or cooling to be setback or shut off Independently of other isolation .
areas; and shall be controlled by a time control device as described above.
§ 122(a&b) Each space conditioning system shall be controlled by an individual thermostat
that responds to temperature within the zone. Where used to control heating, the
control shall be adjustable down to 55 degrees F or lower. For cooling, the
control shall be adjustable up to 85 degrees F or higher. Where used for both
heating and cooling, the control shall be capable of providing a deadband of at
least 5 degrees F within which the supply of heating and cooling is shutoff or
reduced to a minimum.
X § 122(c) Thermostats shall have numeric setpoints In degrees Fahrenheit (F) and
adjustable setpoint stops accessible only to authorized personnel.
§ 112(b) Heat pumps shall be installed with controls to prevent electric resistance
supplementary heater operation when the heating load can be met by the heat
pump alone.
EnergyPro By EnergySoft User Number: User Job Number: 06-002 Page:20 of 31
MECHANICAL MANDATORY MEASURES
PROJECT NAME
Washington Park - Shops 4.
Part 2 of 2 " MECH-MM
DATE
5/9/2006
Description
Designer
Enforcement
Ventilation
r§ 121(,). Controls shall be provided to allow outside air dampers or devices to be operated at
the ventilation rates as specified on these plans.
FX] § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be
provided on the outside air intakes and discharges of all space conditioning and
exhaust systems.
FXJ § 122(f) Ali gravity ventilating systems shall be provided with automatic or readily accessible
manually operated dampers in all openings to the outside, except for combustion air
openings.
§ 121(f)1 Air Balancing: The system shall be balanced in accordance with the National
Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or
Associated Air Balance Council (AABC) National Standards (1989); or
X❑ §121(f)2 Outside Air Certification: The system shall provide the minimum outside air as
shown on the mechanical drawings, and shall be measured and certified by the
installing licensed C-20 mechanical contractor and certified by (1) the design ,
mechanical engineer, (2) the Installing licenced C-20 mechanical contractor, or (3) the
person with overall responsibility for the design of the ventilation system; or
F] § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or
remote device capable of measuring the quantity of outside air on a continuous
basis and displaying that quantity on a readily accessible display.divice; or
§ 121 (f)4 Another method approved by the Commission.
Service Water Heating Systems
a§ 113(b)2 If a circulating hot water system Is installed, it shall have a control capable of
automatically turning off the circulating pump(s) when hot water is not required.
X❑ § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the "
outlet temperature to 110 degrees F.
X❑ § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the
following:
Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per
minute.
Foot actuated control valves, and outlet devices that limit the flow of hot water to a
maximum of 0.75 gallons per minute.
Proximity sensor actuated control valves, and outlet devices that limit the flow of hot
water to a maximum of 0.75 gallons per minute.
Self-closing valves, and outlet devices that limit the flow of hot water to a maximum
of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system).
Self-closing valves, and outlet devices that limit the flow of hot water to a maximum
of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system).
Self-closing valves, and outlet devices that limit the flow of hot water to a maximum
of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor
controls).
EnergyPro By EnergySoft User Number: User Job Number: 06-002 Page:21 of 31
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Washington Park - Shops 4 5/9/2006
SYSTEM NAME FLOOR AREA
RTU -1 1.385
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
55,000
Total Output (Btuh)
55,000
Output (Stub/sqft)
39.7
Cooling System
Output per System
63,800
Total Output (Btuh)
63,800
Total Output (Tons)
5.3
Total Output (Btuh/sqft)
46.1
Total Output (sgft/Ton)
260.5
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sqft)
1.44
Airflow (cfm/Ton)
376.2
Outside Air (%)
23.6
Outside Air (cfm/sqft)
0.34
Note: values above given at ARI conditions
26.0 of
— )0 ;0
Outside Air
472 cfm
69.8 of
59.4 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensiblel Latent
I I CFM I Sensible
1,536
31,059
5,98
267
9,934
0
1,553
497
0
0
472
18,206
8,675
472
21,992
0
0
1,553
497
52,451 14,656 32 919
CARRIER 50HJQ006 52,051 6,067 34,352
Total Adjusted System Output 52,051 6,067 34,352
(Adjusted for Peak Design Conditions) —- --
TIME OF SYSTEM PEAK Jul 4 pm Jan 12 am
earn Temperatures at Time of Heating Peak)
105.0 of 105.0 of
Heating Coil
Supply Air Ducts
Supply Fan 104.8 of
2000 cfm ROOMS
70.0 of
o,.a..... A:_ n.._a_ E I
r '% (r%cwi 11 nu vucw 7
TOOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
11.0 / 77.6 of 83.3 66.2 of 55.0 / 53.7 of 55.0 / 53.7 of
Supply Air Ducts
Outside Air �'
472 cfm
Cooling Coil Supply Fan 55.7 / 54.0 of
2000 cfm 50.5% R.H. ROOMS
74.7/62.1 of 74.0 61.8 of
Return Air Ducts I
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page:22 of 31
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Washington Park - Shops 4 5/9/2006
SYSTEM NAME FLOOR AREA
RTU -2 1.516
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
55,000
Total Output (Btuh)
55,000
Output (Btuh/sqft)
36.3
Cooling System
Output per System
63,800
Total Output(Btuh)
63,800
Total Output (Tons)
5.3
Total Output (Btuh/sqft)
42.1
Total Output (sgft/Ton)
285.1
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sqft)
1.32
Airflow (cfm/Ton)
376.2
Outside Air (%)
25.8
Outside Air (cfm/sqft)
0.34
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD 56,145]777;5;A 35 374
HVAC EQUIPMENT SELECTION
CARRIER 50HJQ006 52,775 5,748 34,352
Total Adjusted System Output 52,775 5,748 34,352
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Jul 4 pm Jan 12 ann
COIL COOLING PEAK_
COIL HTG. PEAK
CFM
Sensible
Latent
I CFM
Ls
Note: values above given at ARI conditions I I
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0 of 58.5 of 105.0 of 105.0 of
0` Outside Air Supply Air Ducts
517 cfm
Heating Coil °F
69.8 of
Supply Fan 104.8
2000 cfm ROOMS
70.0 of
Return Air Ducts I
'DOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
111.0 / 77.6 of 84.1 166.6 of 55.0 / 53.7 of 55.0 / 53.7 of
r ...
Supply Air Ducts
Outside Air
517 cfm
Cooling Coil Supply Fan 55.8 / 54.0 of
2000 cfm 50.7% R.H. ROOMS
74.8/62.1 of 74.0 61.9 of
Return Air Ducts I
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page:23 of 31
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Washington Park - Shops 4 5/9/2006
SYSTEM NAME FLOOR AREA
RTU -3 1,516
ENGINEERING CHECKS 11SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
55,000
Total Output (Btuh)
55,000
Output (Btuh/sgft)
36.3
Cooling System
Output per System
63,800
Total Output (Btuh)
63,800
Total Output (Tons)
5.3
Total Output (Btuh/sqft)
42.1
Total Output (sgfUTon)
285.1
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sgft)
1.32
Airflow (cfm/Ton)
376.2
Outside Air (%)
25.8
Outside Air (cfm/sgft)
0.34
Dte: values above given at ARI conditions
;ATING SYSTEM PSYCHROMETRICS
26.0 of 58.5 of
Outside Air
517 cfm
69.8 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
COIL COOLING PEAK
COIL HTG. PEAK
CFM Sensible Latent
CFM Sensible
1,626
32,878
6,546
276
10,278
0
1,644
514
0
0
517
19,905
9,383
517
24,068
0
0
1,644
514
TOTAL SYSTEM LOAD F 56,14 15,930 —35,374
HVAC EQUIPMENT SELECTION
CARRIER 50HJQ006 52,775 5,748 34,352
Total Adjusted System Output 52,775 5,7481 34,352
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Jul 4 pm F Jan 12 am
!am Ile
105.0 of
Heating Coil
Supply Fan
2000 cfm
105.0 of
—>S Supply Air Ducts
104.8 of
ROOMS
70.0 of
a Return Air Ducts I
TOOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
11.0 / 77.6 of 84.1 / 66.6 of 55.0 / 53.7 of 55.0 53.7 of
> Supply Air Ducts
Outside Air y
517 cfm
Cooling Coil Supply Fan. 55.8 / 54.0 of
2000 cfm 50.7% R.H. ROOMS
74.8/62.1OF 74.0/61.9OF
Return Air Ducts I
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page:24 of 31
I
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Washington Park - Shops 4 5/9/2006
SYSTEM NAME FLOOR AREA
RTU -4 1,502
Number of Systems
1
Heating System
Output per System
55,000
Total Output (Btuh)
55,000
Output (Btuh/sgft)
36.6
Cooling System
Output per System
63,800
Total Output (Btuh)
63,800
Total Output (Tons)
5.3
Total Output (Btuh/sqft)
42.5
Total Output (sgft/Ton)
282.5
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sqft)
1.33
Airflow (cfm/Ton)
376.2
Outside Air (%)
25.6
Outside Air (cfm/sqft)
0.34
Note: values above given at ARI conditions
Total Room Loads'
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
CFM I Sensible) Latent I I CFM I Sensible
55.7707[777;:;5
CARRIER 50HJ0006 52,698 5,783 34,352
Total Adjusted System Output I 52,698 5,783 34,352
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Jul 4 pm Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0°F 58.6°F 105.0°F 105.0°F
O Supply Air Ducts
Outside Air
512 cfm - 104.8 °F
Heating Coil Supply Fan
2000 cfm ROOMS
69.8 OF 70.0 OF
Return Air Ducts `S
:DOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
11.0 / 77.6 OF 84.1 / 66.6 OF 55.0 / 53.7 OF 55.0 / 53.7 OF
Supply Air Ducts
Outside Air
512 cfm
Cooling Coil Supply Fan 55.8 / 54.0 OF
2000 cfm 50.7% R.H. ROOMS
74.8/62.1°F 74.0/61.9°F
Return Air Ducts
I EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Paae:25 of 31 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Washington Park - Shops 4 5/9/2006
SYSTEM NAMEFLOOR AREA
RTU -5 1,502
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
55,000
Total Output (Btuh)
55,000
Output (Btuh/sqft)
36.6
Cooling System
Output per System
63,800
Total Output (Btuh)
63,800
Total Output (Tons)
5.3
Total Output (Btuh/sqft)
42.5
Total Output (sgft/Ton)
282,5
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sgft)
1.33
Airflow (cfm/Ton)
376.2
Outside Air (%)
25.6
Outside Air (cfm/sqft)
0.34
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
1COILHTG.PEAK
CFM I Sensiblel
Latent
I CFM I Sensible
55,770 15,795
35,129
CARRIER 50HJ0006 52,698 5,783 34,352
Total Adjusted System Output 52,698 5,783 34,352
(Adjusted for Peak Design Conditions)—�
TIME OF SYSTEM PEAK Jul 4 om I I Jan 12 aml
iEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures
at Time of Heating
Peak)
26.0 OF 58.6 of
105.0 of
105.0 of
Supply Air Ducts
Outside Air
�.
512 cfm
104.8 °F
Heating Coil
Supply Fan
2000
cfm
ROOMS
70.0 of
69.8 of
Return Air Ducts
I
:.DOLING SYSTEM PSYCHROMETRICS
(Airstream Temperatures
at Time of Cooling
Peak)
111.0 / 77.6 of
84.1 / 66.6 of
55.0 / 53.7 of 55.0 / 53.7 of
311 ;11110'
0 '
Supply Air Ducts
Outside Air
512 cfm
Cooling Coil Supply Fan
55.8 / 54.0 of
2000 cfm
ROOMS
50.7% R.H.
74.8/62.1 of
74.0161.9 of
at 10-
Return Air —)ucts
I
EnergyPro 4.1 by EnergySoft User Number: 3358
Job Number: 06-002
Paae:26 of 31
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Washington Park - Shops 4 5/9/2006
SYSTEM NAME FLOOR AREA
RTU -6 1.515
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
55,000
Total Output (Btuh)
55,000
Output(Btuh/sqft)
36.3
Cooling System
Output per System
63,800
Total Output (Btuh)
63,800
Total Output (Tons)
5.3
Total Output (Btuh/sgft)
42.1
Total Output (sgft/Ton)
285.0
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sgft)
1.32
Airflow (cfm/Ton)
376.2
Outside Air (%)
25.8
Outside Air (cfm/sgft)
0.34
Note: values above given at ARI conditions
26.0 of
— �0 :0
Outside Air
516 cfm
69.8 of
58.5 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM Sensible Latent
CFM Sensible
1,625
32,866
6,542
276
10,277
0
1,643
514
0
0
516
19,892
9,378
516
24,052
0
0
1,643
514
56,1181 15.9201 35 356
HVAC EQUIPMENT SELECTION
CARRIER 50HJ0006 52,770 5,751 34,352
Total Adjusted System Output 52,770 5,751 34,352
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Jul 4 pm I Jan 12 am
?am I em
105,00F
Heating Coil
105.0 of
Supply Air Ducts
Supply Fan 104.8 of
2000 cfm ROOMS
70.0 of
Return Air Ducts I
vvr`uvu 0 T 0 1 t`M rOTL NKUMt I Kwa Airstream Iem eratures at Time of Cooling Peak
111.0/77.60F 84.1 166.6 of 55.0 / 53.7 of 55.0 / 53.7 of
Outside Air
Supply Air Ducts
�.. }
516 cfm
Cooling Coil Supply Fan 55.8 / 54.0 of
2000 cfm 50.7% R.H. ROOMS
74.8/62.10F 74.0/61.9OF
h Return Air Ducts 4
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page:27 of 31 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Washington Park - Shops 4 5/9/2006
SYSTEM NAME FLOOR AREA
RTU -7 1,905
Number of Systems
1
Heating System
Output per System
69,000
Total Output (Btuh)
69,000
Output (Btuh/sqft)
36.2
Cooling System
Output per System
76,000
Total Output(Btuh)
76,000
Total Output (Tons)
6.3
Total Output (Btuh/sqft)
39.9
Total Output (sgft/Ton)
300.8
Air System
CFM per System
2,400
Airflow (cfm)
2,400
Airflow (cfm/sqft)
1.26
Airflow (cfm/ron)
378.9
Outside Air (%)
27.1
Outside Air (cfm/sqft)
0.34
Note: values above given at ARI conditions
:ATING S
26.0 OF
311�
Outside Air
649 cfm
69.6 OF
11.0 / 77.6 OF
310�
Outside•Air
649 cfm
75.0/62.3 °F
57.8 OF
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM I Sensiblel Latent
CFM
I Sensible
82,300]:::=19957
53_429
CARRIER 50HJQ007 65,462 4,564 43,096
Total Adjusted System Output 65,462 4,564 43,096
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 4 pm F Jan 12 am
yam i em
105.0 °F
Heating Coil Supply Fan
2400 cfm
\irstream T
84.8 / 66.9 OF
105.0 OF
—�OSupply Air Ducts
104.6 OF
ROOMS
70.0 OF
Return Air Ducts
55.0153.6 -OF
Cooling Coil Supply Fa
2400 cfm
55.0 / 53.6 of
Supply Air Ducts
Fan
56.0/54.1OF
50.9% R.H. ROOMS
74.0 / 61.9 OF
Return Air Ducts I
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page: 28 of 31
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Washington Park - Shops 4 5/9/20C
SYSTEM NAME FLOOR AREA
RTU -8 2,022
ENGIN
Number of Systems
1
Heating System
Output per System
85,000
Total Output (Btuh)
85,000
Output(Btuh/sgft)
42.0
Cooling System
Output per System
91,300
Total Output (Btuh)
91,300
Total Output (Tons)
7.6
Total Output(Btuh/sgft)
45.2
Total Output (sgftrron)
265.8
Air System
CFM per System
3,000
Airflow (cfm)
3,000
Alrflow (cfm/sgft)
1.48
Airflow (cfm/Ton)
394.3
Outside Air (%)
23.0
Outside Air (cfm/sgft)
0.34
Note: values above given at ARI conditions
26.0 of
— ), ;0
Outside Air
689 cfm
69.7 of
111.0 / 77.6 of
Outside
��
689 cfm
74.8/62.1 of
SQ 7 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensible Latent
CFM
Sensible
2,466
49,870
8,731 520
19,372
0
2,493
969
0
0
689
26,536
. 12,714
F 689
32,055
2,418
-2,418
2,493
969
83.9791 21 445 50,9471
CARRIER 50HJ0008 76,680 6,344 53,089
Total Adjusted System Output 76,680 63441 53,089
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Jul 4 pm Jan 12 am
Heating Coil
at Time
Supply Fan
3000 cfm
105.8 of
—� Supply Air Ducts
105.5 of
ROOMS
70.0 of
h Return Air Ducts
i,irstream Temperatures at Time
83.1 /66.10F55.0 . / 53.7 of
� /._
Cooling Coil
Supply Fan
3000 cfm
55.8 / 54.0 OF
—�j Supply Air Ducts
56.6 / 54.3 of
50.4% R.H. ROOMS
74.0 / 61.8 of
h Return Air Ducts
I EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page: 29 of 31
A •'
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Washington Park - Shops 4 5/9/2006
SYSTEM NAME FLOOR AREA
RTU -9 1,542
ENGINEERING CHECKS ISYSTEM LOAD
Number of Systems
1
Heating System
Output per System
55,000
Total Output (Btuh)
55,000
Output (Btuh/sgft)
35.7
Cooling System
Output per System
63,800
Total Output(Btuh)
63,800
Total Output (Tons)
5.3
Total Output (Btuh/sgft)
41.4
Total Output (sgftrron)
290.0
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sgft)
1.30
Airflow (cfmrron)
376.2
Outside Air (%)
26.3
Outside Air (cfm/sgft)
0.34
Note: values above given at ARI conditions
IEATING SYSTEM PSYCHROMETRI
26.0 OF
— )o :0
Outside Air
526 cfm
69.8 OF
112.0 / 77.9 OF
311�
Outside Air
526 cfm
74.8/62.1 °F
58.3 OF
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
I Sensible
1,563
31,609
,6,659
277
10,317
0
1,580
516
0
0
526
20,831
9,525
526
24,480
0
0
1,580
516
55,692 16,183 35,829
HVAC EQUIPMENT SELECTION
CARRIER 50HJ0006 53,149 5,213 34,352
Total Adjusted System Output 53,149 5,213 34,352
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 3 pm an 12 am
105.0 °F
Heating Coil
s at Time
Supply Fan
2000 cfm
105.0 OF
-� Supply Air Ducts
104.8 of
ROOMS
70.0 OF
h Return Air Ducts `;
Urstream Temperatures at
84.6/66.8°F M 55.0/53.6°F
Cooling Coil
of Cooling Peak)
55.0 / 53.6 OF
-----�j Supply Air Ducts
Supply Fan 55.8 / 53.9 °F
2000 cfm 50.8% R.H. ROOMS
74.0 / 61.9 OF
Return Air Ducts
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page: 30 of 31
r
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Washington Park - Shops 4 5/9/2006
SYSTEM NAME FLOOR AREA
RTU -10 1,542
ENGINEERING CHECKS IFSYSTEM LOAD
Number of Systems
1
Heating System
Output per System
55,000
Total Output (Btuh)
55,000
Output (Btuh/sgft)
35.7
Cooling System
Output per System
63,800
Total Output (Btuh)
63,800
Total Output (Tons)
5.3
Total Output (Btuh/sqft)
41.4
Total Output (sgftrron)
290.0
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sgft)
1.30
Airflow (cfmrron)
376.2
Outside Air (%)
26.3
Outside Air (cfm/sgft)
0.34
ote: values above given at ARI conditions
:ATING SYSTEM PSYCHROMETRI
26.0 of 5F
Outside Air
526 cfm
69.6 of
12.0 / 77.9 of
Outside Air
526 cfm
75.0/62.2 of
EnergyPro 4.1
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
I COIL HTG. PEAK
CFM Sensible Latent
CFM Sensible
2,127
43,004
6,659
508
18,922
0
2,150
946
0
0
526
20,693
9,540
526
24,367
0
0
2,150
946
68,0051 16,199 45,1811
CARRIER 50HJQ006 53,398 5,010 34,352
Total Adjusted System Output 53,398 5,010 34,352
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 3 pm Jan 12 am
I
ream Temperatures at Time of Heatina Peakl
,o, _ —„o,
Heating Coil Supply Fan
2000 cfm
105.0 of
—� Supply Air Ducts
104.6 of
ROOMS
70.0 of
b Return Air Ducts � I
(Airstream Temperatures at Time of Cooling Peak)
84.7 / 66.8 of 55.0 / 53.6 of 55.0 53.6 of
Supply Air Ducts
Cooling Coil Supply Fan 56.0 / 54.0 of
2000 cfm 50.7% R.H. ROOMS
74.0 / 61.9 of
User Number: 3358
Return Air Ducts
Job Number: 06-002
1 of 31