Loading...
0302-050 (CCOM)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date r D Tac Date +�% ?� i Signature o�t � cto OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section , B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. (cif 1 have and will maintain workers' compensation insurance, as required by Seetibn 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier STATE FUND Policy No. ISWI39 2002 (This section need not be completed if the permit valuation is for $100.00 or -less). () I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become"subject to the/ workers' compensation laws of California, and agree that if `ho suld . ecome subject to the,workers' compensation provisions of Section 3700 of the La, or Code, I-shallFforthwith comply with th � e provisions. �/� Date: %-4 /1Zc, Applicant Warring: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety, for a permit subject to the conditions and restrictions set forth on his- application: is-application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City,,and State laws relating to the buildin) construction, and hereby authorize -representatives of this City -to enter up R-- the above-mentioned property for inspection purposes./%' igriature (Owner/Agent)/�.. Date%'' PERMIT#' BUILDING PERMIT ' 41,V,2_WM DATE VALUATION s44,4um LOT TRACT �y JOB SITE ADDRESS 47 -OW WA+ + I�GT0.N �',R r APN OWNER CONTRACTOR/DESIGNER/EN (NEER LPT-1 TQC 00J_W J MC l: ERMOT'4'f.1b.IC i7MM(YIT FNT PO BOX 14447 PO BOX 163 P' VM L'+it, ERT C.A. 92260 ROMA DMIMI T Com. 92261 (1600,46.0745 CRUf 6541 USE OF PERMIT -t 14 9'x 1t;' 'A TPLY .1-.P". FL091i DOM INVi 1141,L90 C, bt.Lk, 1 U%.v !L" .- QArZACIIE ARPORT ZkSMIoW i D COS OS' 1lbiliE7.i..Fbl/l.R..44iN 44.455.30 PF-Rwi' Me Uffl'rdM/f RY CC I STR.vC' ION IME 101.000.418-000 $382.00 PLAN CHECK RX 101-(5W-439-318 M&22 STRO?BC:MOTION FEE -COMM 100.0110441.000 0.34 AFt'.f' IN PlifILIC PLACES •, 2 OMI 270-000-4441-1100 $1,22.26 SUB -TOTAL COkT="IJ(MCy24'AND F tI. W CWE, CCK. $901.82 I.F09 PRE -PAID FE M' $0100 71 � �� MA 02)3 IC �� r I T/ t 11"4c Ft. OECEIPT DATE By le DATE7AAr INSPE R - 00 ERT INSPECTION'RECORD OPERATION DATE INSPECTOR e OPERATION , : - `bATE INSPECTOR BUILDING APPROVALS,., MECHANICAL APPROVALS - Set Backs Underground Ducts Forms & Footings 3 d 3. Ducts Slab Grade ; Return Air Steel Combustion Air Roof Deck Exhaust Fans OX to Wrap _ F,A.U. Framing Compressor Insulation Vents - Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall - Exterior Lath Drywall - Int. Lath - -Final Final BLOCKWAL(APPROVAL-9 POOLS - SPAS Steel Set Backs Electric -Bond — = Footings Main Drain Bond Beam Approval to Cover Equipment Location _ Underground Electric Underground Plbg. Test Final Gas Piping - PLUMBING APPROVALS • Gas Test Electric Final v Waste LinesHeater Final - Water Piping Plumbing Final Plumbing Top Out. Equipment Enclosure Shower Pans - - O.K for Finish Plaster Sewer Lateral ;; _ Pool Cover Sewer Connection. Encapsulation Gas Piping - Gas Test Appliances - Final ' - - - ...._ Finel Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power.Pole Underground Conduit -• Rough Wiring Low Voltage Wiring Fbdures Main Service Sub,Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: "/ice _ - • •f6. .A 11 4 M J z c511-4 7-0 OZ,.n, /Dv, {'�fikNNl&R 1 6S 1_��kiVS — %vl�,�l>ccrgla� 47WyitW4A Bin # c� City of La Quints�p I. Building 8t Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 • (760) 777.7012 Building Permit Application and Tracking Sheet Permi0 Project Address: y " V'3 \^ i %vner's Name: L. N t A. P. Number: Address:. O oY \ *A N'l Legal Description: S Contractor:c City. ST. Zip: d� _ '�� a Y� A elephone: �. Address: p u� Project Description: NO Cite. ST. Zip: r C¢ {� CL. v Q -r e 1 C e, u r �•� Telephone: 030,A' 9xi� State Lic. a : Arch.. Ener.. Designer: _6 City Lic.::6 q% .. SID �� 9,�/� �� 0 363-471 47e el (8 'r 0303 • 27 Address: X76 e 00 .r y 0 3d3 - 27 City. ST. Zip: (5 10(del o 30 ' .1 7 Telephone: 770 "t 8 D03 •.17."5 Construction Type: Occupancy: State Lic. 0: Project t% PC Icircle one): New Add'n Alter Repair Demo Name of Contact Person: �_ Qn v o Sq, Ft.:-IO.b44 It Stones: b Units: Telephone # of Contact Person: C) cj Estimated Value of Proiect: APPLICANT: DO NOT WRITE BELOW THIS LINE +� Submittal Req'd Recd TR"1CKING PERMIT FEES n Sets Plan Check submitted Z J Item Amount *Truss Mural Cales. Reviewed. ready for corrections Plan Check Deposit Calcs. Called Contact Person Plan Check Balance Title 23 Cales. Plans picked up 71 V ("onstruction Flood plain plan 'i Plans resubmitted ! bi Mechanical Grading plan 2" Review. ready fo Electrical mhinE Subeontactor List Call Contact Person Grant Deed Plans picked up S.M.1. H.O.A. Approval Plans resubmitted GradinE IN HOUSE:- '" Review. ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person .I.P.P. Pub. Wks. Appr School Fees Date of permit issue Total Permit Fees M J z c511-4 7-0 OZ,.n, /Dv, {'�fikNNl&R 1 6S 1_��kiVS — %vl�,�l>ccrgla� 47WyitW4A i- . unit,% i To: Greg Butler, Building & Safety Manager To CDD: z1S1p 3 From: W Alf -96 1 , PlanningDue date: Status: - Building Plans Approval (this is an approval to issue a Building Permit) The Community Development Department has reviewed the Building Plans for the following project: Description: �o, o y� JF /�I/V6 Goul2S Address or general location: `� 0'V NG, „✓ S, i APN and/or legal description: The Community Development Department finds that: O ...these Building Plans do not require Community Development Department approval. ...these BuildingPlans are approved by the Community Development Department. o is { lig/ /✓ Z�Z �v3 Planning+Date R ' :r , ZJS ENGINEERING - SERVICES INC.. 350 S. MILLIKEN,. SUITE A ONTARIO, CALIFORNIA 91761. PHONE ( 909) 974 4150 FAX: ( 909•) 974 4153 CITY.OF LA QUINTA ,. BUILDING &SAFETY DEPT. APPROVED FOR-cowsTRucTION STRUCTURAL CALCULATIONS �� BY DATEv� CUSTOMER - MCDERMOTT ENT ,< W. W. Nelsonw> DATE September 4, 2002 JOB NUMBER 15492='oz , CONTENTS Sigle Pose Carport < (18') x 18' x 8'-6" Clear > 1. Basin: Loads ( 2.5/20/ 0./80. C) ` 2._Check Sheeting ( 29ga HR=36, BHP -E) 3. Check Rafters/Beams 4. Check Column 5. Check Footing w ` Appendix; ESSIDNq c No.54869 Exp. 6730/0 CM1. OF CA�.�F SEP 0 t 20Q2 Page Number 2 Designed By: Z.J.S.ENGINEERING SERVICES INC. Job # 15492-02 350 S.Mi11iken;#A.ONTARIO,Ca91761 Janos Boros P.E. PHONE (909) 974-4150 Date 9- 4-2002 Reference: MCDERMOTT ENT.< W.W. Nelson >. Description: Carport DESIGN CRITERIA This building was designed using the criteria listed below. Capacity for loads greater,'than,these or for, load combinations other than shown below specifically neither intended nor implied. 1. BASIC LOADS 1.1. Dead.Load , 2.5 lb 2 pDL ft. 1.2. Live Load Refer To Table No. 16-C Of UBC 1997 p = 20 lb LL ft 1.3. Wind Load-* Refer To Table No:. 16-F, G,'H .Of UBC 1997 qs = 16.4 lb2 80. MPH ft. , C = 1.06 -.Exposure C From Table'No. 16-G Of UBC 1997 e ( Average Height Of The Building < 15 ft ): Importance Factor P qs Ce I 17.28 lb 2 WL ft i• .. For Actual Cq Values See Thru-Out Calculations !` 1.4. Seismic Load Seismic Zone 4 Ca = 0.44 Na =-0.57 As Given In Table 16-Q Of UBC 1997 Na = 1.'3 As Given ,In Table,16-S Of UBC 1997 a Page Number 3 ` Job # 15492-02 .� By:. Z.J.S.ENGINEERING SERVICES INC. Jo In Compression 350 S.Milliken;#A.ONTARIO,Ca9.l761 Compression VEDesigned oros P.E.— PHONE -'(909)-97474150 Date 9- 4-2002 Reference: MCDERMOTT ENT < W.W. Nelson > Description: Carport I_ .. 2 . CHECK ROOF DECKING x , + Use: 29 GA Galv. Steel HR -36, BHP_ Or Equal. Material c Steel ASTM;A446 Grade E, FY 80 ksi Gauge, Weight Panel Top: In Compression Panel Bottom In Compression ksi. - PPL I+ S+ Fb+ I_ .. S_ Fb- ft. - lb in4 in3 ft. a- i in4 in3. - Uniform Load R ksi — •.— ksi - .ft2 ft ft ft ft 29 0.70 0.0567 '0.0600 N 48.0 0.0598 0.0638 48.0 26 0.95 0.0818 0:0909 48.A 0.0851:11 0.0898 '48.0 24 1.20 0.1116 0.1234 48.0 0.1141 0.1156 48.0 E = 29. 103 ksi.. - Modulus Of Elasticity Of Steel Fy = 80.00 ksi. - Minimum Yield Stress' e 10.0 ft. - Span Between Two Supports b = 1.0 ft. - One Foot Wide Strap Being Check a = 4.0 ft. a- Overhang Of The•Sheet w - Uniform Load R -. End Beam Reaction S - Required Section Modulus RQ. M - 'Max. Moment MAX. w R T R a 2 an R Page Number 4 Designed By: Z.J.S.ENGINkERING SERVICES INC. Job # 15492-02 • ` R Page Number 4 Designed By: Z.J.S.ENGINkERING SERVICES INC. Job # 15492-02 350 S:Mi11iken'#A.0NTARI0,Ca91761 ` Janos Boros P.E. PHONE 4909)"974-4150 Date 9- 472002 Reference: MCDERMOTT ENT < W.W. Nelson Description: Carport _> 2.1.1. For Dead Load + Live Load lb. w = ( p + p ) b = 22.5 LL DL+LL DL. w R +2a) _ RDL+LL DL+LL .0:20 kips 2 wDL+LL (2 1RP ;. M _ _ 1.21. kip' in, DL+LL 2 DL+LL a 2• • , w r _ MDL+LL DL+LL = 2.16 kip -in. 2 AT SUPP. M D L+LL 3 r 3' . SRQ = = 0.05 in., < . S 0.06 in.- oM6x Fy . 2.1.2. Dead'Load + Wind Load '. Cq = 1.3 Refer To Table No. 16-H Of UBC 1997 lb.. ". w = ( C p -`.p ) b = 20.09 WL DL DL+WL Q . ff. y R __ DL+ = 0.18, kips,' , DL+WL 2 x E a - y. M wDL+WL (2 + a) _ R P 1,.08 kip -in. DL+WL 2 DL+LL 2 H Page Number 5 Designed By: Z.J.S.ENGINEERING SERVICES INC. Job # 15492-02 350 S.Milliken;#A.ONTARIO,Ca91761 .Janos Boros P.E. PHONE (909) 974-4150 Date 9- 4-2002 Reference: MCDERMOTT ENT < W.W. Nelson > Description: Carport" 3. CHECK RAFTERS/BEAMS 3.1. Check Rafter s Use: ( 10" x 21/2" x 14,GA. or Equivalent as Rafter. Connect With,(4) #14,TEKS V = 0.92 kips From.Appendix For 14 GA. To 14,.GA. ALLOW TEKS E = 29. 103 ksi. - Modulus.Of Elasticity -,Of -Steel Fy = 55.00 ksi. - Minimum Yield Stress, 2 = 18.0 ft. Span Between Two Supports b 9.0 ft. - Spacing,Of The Rafter a, 9.0 ft. - Overhang Of The Rafter MA = 106.9 kip -in Allowable moment For Bending See ICBO ER -5409 R - End Beam Reaction M Max. Moment MAX. w' a R R T E a a 3.1.1. For Dead Load + Live Load 1b. wDL+LL ( pDL+ PLL ) b_. = 166.5 • w U +2a) R _ DL+LL = 2.99 ` kips < 4 V DL+LL 2 ALLOW ; TEKS _ wDL+LL 2 MDL+LL 2 RDL+LL 2 - 0 klp-ln:. BETWEEN SUPPORTS 1. S w a 2 _ DL+LL M _ 80.9 kip -in. ATLSLPP. 2 s M = 80.9 kip -in < MA = 106:9 kip -in CK - DL+LL " r MAX. See ICBO ER -5409 6 Page Number :,6 Designed By: Z.J.S.ENGINEERING SERVICES INC. Job ,# 15492-02 • .350 S.Mi11iken;#A.ONTARIO,Ca91761 Janos Boros P. E. PHONE (909)974-4150 Date 9- 4-2002 Reference: MCDERMOTT ENT < W.W. Nelson > Description: Carport - ' 3.1 2. Dead Load + Wind Load Tributary Area b ( e + a�) 243 ft2 =� Cq = 1.3 -.0.3 1.0 r. Refer To Foot Note #2 'Of Table No. 16-H Of UBC 1997 w =( C p- p ) b= 133.9 lb ." DL+WL Q WL DL f t.' w GQ +2a') _ DL+WL RDL+w� 2 = 2.41 kips ` . < ;1 .33 (' 4'V ), ALLOW TEKS e + 2 M — I DL+WL (2 a) _ R E = 0 'kip -in,. •. `• , DL+WL 2 DL+LL 2 BETWEEN t SUPPORTS ' `2 . w a - _ DL+WL MDL+wL 2 65.0 kip -in, AT SUPP. r See C3.1.3. Of Cold -Formed Spee.11986. Ed. w/ -1989-Addendum M =(0.7) 1.33 MA _" 99.5 kip -in.> 65'.0•kip-in. ' ALLOW Stress Increase Due To Wind Load , Page Number 7 Designed By: Z.J.S.ENGINEERING SERVICES INC. Job # 15492-02 350 S.Milliken;#A.ONTARIO,Ca91761 . Janos Boros P.E. PHONE (909) 974-4150 Date 9- 4-2002 Reference: MCDERMOTT ENT < W.W.,'Nelson > Description: Carport ' 3.2. Check Roof Beams Use: (1 10",x 21/2„ x 13 GA. Connect With (4) 3/4" Dia A325 Bolts V = 1.96 kips From Appendix For .14 GA. To, 14° GA. ALLOW BOLTS E = 29. 103 ksi. Modulus Of Elasticity Of Steel Fy = 55.00 ksi: - Minimum Yield Stress E = 11.5 ft. - Overhang Of The Beam <.Right > b = 18.0 ft: Spacing Of The Beam a = 6.5 ft. - Overhang Of The Beam < Left > MA = 138.9 kip -in - Allowable moment For Bending See ICBO ER -5409 R - End Beam Reaction M - Max. .Moment MAX. w r R T a C 3.2.1. For Dead•Load + Live Load UNBALANCED CONDITION DL+LL ( pDL+ Pb 333 LL = . lb. w - ft. w ( E +a) DL+LL R _ = 5..99' kips < 4 VaLLow . DL+LL BOLTS w Q 2 _ DL+LL OK MDL+LL 2 = 264.2, kip -in: < 2 MA = 277...:9 kip -in AT SUPP. See"ICBO ER -5409 3.2.2. Dead Load + Wind Load Tributary Area': b t 130 ft —� Cq = 1.3 - O:31= 1.01 Refer.To Foot Note #2.Of Table No. 16-H Of UBC • 1997 lb. wDL+WL ( C pWL- pDL) b = 257 ft. w R +a) WL DL+ R' _ = 4.62 kips .< 1.33•( 4 V ) DL+WL ALLOW BOLTS Page Number 8 Designed By: Z.J.S.ENGINEERING SERVICES INC. Job # 15492-02 350 S.Mi11iken;#A.ONTARIO,Ca91761 Janos.Boros P.E. PHONE (909) 974-4150 Date 9- 4-2002 Reference: MCDERMOTT ENT.-< W.W. Nelson -> Description: Carport w e z ` M DL+WL 2 2 = , DL = 203. kip -in. AT SUPP. r See C3.1.3. Of Cold Formed Spec."1986.;.Ed. w/ 1989 Addendum M = 2 (0.7) 1.33 MA = 258.7 kip7in.>.203. kip -in. ALLOW Stress Increase Due To Wind Load 3.2.3. Check Connection At Column f , Use (4) 3/4" Dia. A-325 High Strength Bolts Moment [ kip -in ] = 264.2 - See Above, Critical For DL + LL Axial ( kip l 5.99 - See Above, Critical For DL + LL 7.0 BOLT., i Figure Number Of Fasteners X1 = 4 X1 ( Distance In Inch Bolt Group -CL. To CL Bolt ) = 7.0 ' Number Of Fasteners Y1 4 Y1 ( Distance In Inch Bolt Group CL To CL Bolt-)- 7.0 E x2 1961. , E y2 196. 2 E x + E'y2 392. F Page Number : 9 Designed By: Z.J.S.ENGINEERING SERVICES INC. Job # 15492-02 350. S.Milliken";#A.ONTARIO,Ca91761 Janos Boros P.E. PHONE (909) 974-4150 Date 9- 4-2002 Reference: MCDERMOTT ENT < W.W. Nelson > Description: Carport X E X2 + E M X. Shear F' _ = 0.67 FX' _ = 0. X E X2 + E y2 Sum Of Fasteners M y AX Fy = 0.67 F'' _ = 0.99 E X2 + E y2 y Sum Of Fasteners R _ _ 2.26 kips < 4.22 kips OK . 12 + r I FX + FX' L 12 + F' Fy L J J J See Appendix 4. CHECK COLUMN Use: (1 10" x 2 112" x 12 ga ( Check 5.0" x 5.0".,x 0.105" Square.Tube Section Conservative MA = 161.1 kip -in [ Allowable moment For Bending See ICBO ER -5409 b = 18.0 Ft [ Length Of The Bay ] s = 18.0 Ft [ Width Of 'the Bay ] Purlin Depth = 1.0 Ft [,Depth of Roof Purlins l A = .t s b = 324.F2 [ Horizontal Projected Area For One Column] H Fy", = 50.00 ksi [ Minimum Yield Stress Ft [ Allowable Stress For. Tension ] Fa [ Allowable Average Compression Stress Under Concentric Loading ] Allowable Stress For Tension Ft = 0.6 F = 30.0 ksi y _ .. 4.1. For Dead Load + Live Load PDL+LL ( pDL+ pLL ) AH = 5.99 kip Page Number 10 Designed By: 2.J.S.ENGINEERING SERVICES INC. Job # 15492-02 350 S.Milliken;#A.ONTARIO,.Ca91761 Janos Boros P.E. PHONE (909) 974-4150 Date 9- 4-2002 Reference: MCDERMOTT ENT < W.W. Nelson > Description: Carport Find A1lowable.Strength For Compression For �. 5.00" x 5.00" x 0.105" Square Tube Fy = 50.00 ksi = Minimum Yield Stress A = 2.04 int - Area I 8..11 in4 - Moment Of Inertia S = 3.24 in, - Section',Modulus r, = 1.99 in - Radius '0f Gyration Refer To Section 2217 And 2218 Of'UBC 1997 E = 8.5 ft . k =-2.1 k t 17.85 ft k E= 107.39 < 200 OK r ma2 - Fe = (k P )2_ 25.25 ksi r r If Fe > 2y then Fn = Fy -I 1 4y Fe Else Fn Fe ) .Fn = 25:25 ksi Check Each Element If A = 1.052 w J = > 0.673 then section'is not fully effective ! t E k r 1 0.22 Then Use AEFF A - X I W - W I 'Else,`AEFF "- A — AEFF 2.01 int Pn = AEFF 'Fn = 50.77 kip Pa Pn = 26.44 kip '= Allowable Compressive Strength BALANCED LOAD - DL+L P L = 0.22' Pa Page Number : 11 Designed By: Z.J.S.ENGINEERING SERVICES INC. Job # 15492-02 350 S.Mi11iken;#A.ONTARIO,Ca91761 M 264.2 kip -in. See Above Page 7 Janos Boros P.E. PHONE',(909) 974-4150 Date 9- 4-2002 Reference: MCDERMOTT ENT <_W.W. Nelson > Description: Carport UNBALANCED CONDITION PDL+LL ( PDL' pLL ( 18 ft ) ( 11.5 ft) _ .3.82 kip M 264.2 kip -in. See Above Page 7 DL+LL AT SUPP. M P DULL DL -LL] Combined Stress =" _ 0.96 < 1.0 O K Pa 2 MA 4.2. For Dead Load + Wind Load Cq = 0.7 Refer To.Table No. 16-H Of UBC 1997 PUP = ( Cq PwL PDL ) AH = 3.13 kip Cq = 1.3 Refer To Table No., 16-H Of UBC 1997 Cq . pWL r r Purl in Depth 1 b r PH = 0.40 kip - Lateral Force Per Column MWL PH 2 = 39.0 kip -in. M 203. kip -in. See Above Page 8 DL+WL AT SUPP." M MWL + MDL+wL = 242. kip -in TOTAL AT SUPP. See C3.1.3. Of Cold Formed Spec..1986. Ed. w/ 1989 Addendum r M = 2 (O.7) 1.33 MA = 258.7. kip -in. ALLOW Stress Increase Due To Wind Load P' UP M A TOTAL OK Combined Stress = - =.0.77 < 1.33 Ft MALLOW Page Number 12 Designed By: Z.J.S.ENGINEERING SERVICES INC. Job # 15492-02 ` .ps 1000 Lb2 350 S.Milliken,-#A.ONTARIO,Ca91761. E Min. Soil Pressure ] , Janos Boros P.E. PHONE (909) 974-4150 Date 9- 4-2002 Reference: MCDERMOTT ENT < W.W. Nelson > Description: Carport [ Specific Weight Of Concrete ]• 5. CHECK FOUNDATION ` .ps 1000 Lb2 E Min. Soil Pressure ] , = 150 Lb [ Specific Weight Of Concrete ]• c Ft3 f, = 2500. LbZ __ [ Compressive Strength Of•The Concrete] ' in PL 150 Lb 2 [ Min. Lateral. Bearing Pressure ] _ Ft 130 Lb PF = [ Min. Lateral Sliding Resistance ) Ft 5.1 @Typical Use 2 Ft. - 0 -fn' Dia. x 6 Ft. - 0 In. Deep Concrete Footing D = 6.00 Ft [ Depth Of The Footing - ] r = 1.00 Ft "` [ Radius Of.The.Footing A = r2 n =.3.14 Ft.2 [ Area Of The Bottom Of The •footing ] 5.1.1. Vertical Down P = 5.99 kips ' VERT. DOWN - PVERT. 2.00 p = 2000 Lb, Dowty = ,1907 Lb OK Ft A' Ft z D2 DUE TOSEPTH 5.1.2. Vertical.Up , P = 3.13 kips ' VERT. UP , P _ A D C = 2.83 kips WEIGTH FOOTING Page Number 13 Designed By: Z.J.S.ENGINEERING SERVICES INC. Job # 15492-02 350 S.Mil1iken;#A.ONTARIO,Ca91761 Janos Boros P.E. PHONE (909) 974-4150 Date 9- 4-2002 Reference: MCDERMOTT ENT < W,.W. Nelson.> Description: Carport Safety 2 Stress Increase Due �. To Wind Or Seismic 1.33 p PFRICT. (. 2 ) (2 r n) 6 S: D = 4.19 kips Refer Tb Section 1807.10 Of UBC 1997. P = 7.02 kips TOTAL RESISTING P TOTAL RESISTING Safety = P = -2.24 OK ,. VERT. UP 5.1.3.Check For Lateral Load As Per Sec. 1806.7 UBC 1997 For Unbalanced Load Use 2 ft - 0 in Dia. x 6 ft - 0 in De4tp Round Footing b = 2.00 ft - Diameter Of The Footing d = 6.00 ft Depth Of The.Pile lb 2 pa = 300 ft - Per Table 18 -I -A Of UBC 1997 ft of Depth Footnote #3 Table 18 -I -A S = ( 2 ) ( pa ) d = 3600 lb, 3 2 ft S3 S1 = = = 1200. psf 3 M 264.20 kip -in Maximum Moment At The Base, See Page 11 Of The Calculations MAXMAx h = 9.50 ft Distance In Feet From Ground Surface To Point Of 'Application Of "P" P =MX = 2318 lb - Applied Lateral Force In Pounds h A = 2.344 P 2.26 S b 1 Page Number : 14 Designed By: Z.J.S.ENGINEERING SERVICES INC. Job # 15492-02 d=6.00 ft= 350 S.Mi11iken;#A.ONTARIO,Ca91761 1+4.3A6h Janos Boros P.E. - PHONE (909) 974=4150 Date 9- 4-2002 Reference: MCDERMOTT ENT < W.W. Nelson > Description: Carport d=6.00 ft= 1+" 1+4.3A6h _6.10 ft OK 2 5.1.4.Check Alternate Spread Footing Unbalanced Live Load Governs ! Use 3 Ft. - 6 In. x 7 Ft. - 0 In.•x 2 Ft. - 0 In. Deep Concrete Footing ALLOW SOIL PRESS [KSF] 1.2 20 % INCREASE DUE TO DEPTH AXIAL [K] 3.82 ( See Page ll) MOMENT [KFT] 22.kip-ft ( 264.2 kip -in, See Page 11) DEPTH OF, FTG [FT] 2 WIDTH OF FTG [FT] 3.5 LENGTH OF FTG {FTI 7 WT OF FTG = 7.4 SUM OF WT ,+ AXIAL = 11.2 Mresisting = 39.1 Moverturning 22.0 Mr - Mo 17.1 X = 1.53 r. . E = 1.97. B/6 = 1.17 UPLIFT RES. BY FRICTION.,= 11.2 UPLIFT RESISTED _ 18.5 FRICTION RESISTED P/3 3.7 FB [KSF] _. 1.39 M.[KFT/12in] 4.5 V (tension) [KIP] _ = 7.6_ V (pun.shear [KIP] _ 16.4 Min. Depth [IN.] = 6.5 Min. Depth [IN.] = 4.6 SX (CONCRETE) 48.0 MR (CONCRETE) = 3.4 - USE #5'@ 12 in. c/c NP - -------------- _ .009 K _ .124 J = .959 2/KJ 16.9 Mr (concrete) Fc*depth"2*WI/K1*12 (kft/12inch) = 24. Mr (steel) Fs*depth*.As*J/12 (kft/12inch) = 7. Page Number 15 Designed By: Z.J.S.ENGINEERING SERVICES INC. Job # 15492-02 1/2" Dia. 350 S.Mi11iken;#A.ONTARIO,Ca91761 3/4" Dia. Janos.Boros P.E. PHONE (909)-974-4150 Date 9- 4-2002 Reference: MCDERMOTT ENT'< W.W. Nelson > Description: Carport , ;,. .. Appendix, Allowable Shear (kips) For Bolts ,Per Table V-4.5 of the Cold -Formed Specifications AISI STEEL` THICKNESS in. 1/4" Dia. 3/8" Dia. 1/2" Dia. 5/8" Dia. 3/4" Dia. A307 A325.;`�A307 A325 A307 A325 IA307 A325 A307 A325 (GAUGE) 0.49 1.03 1.10 2.32 1.96 4.12 3.07 6.44 4.42 9.28 .1046 (12) 1.97 1.97 2.95 2.95 3.94 3.94 4.92 4.92 5.91 5.91 .0747 (14) 1.41 1.41 '2.11 2.11 2.81 2.81 3.52 3.52 4.22 4.22 .0598 (16) 1.12 1.12 1.69 1.69 2.25 2.25 2.81 2.81 3.38 3.38 .0478 (18) 0:90 0.90 -1:35 1.35 1.80 1.80 2.25 2.25 2.70 2.70 .0359 (20) 0.68 0:68 1.01 1`.01 1.35 1.35 1.69 1.69 2.02 2.02 Page.Number 16 Designed By: Z.J.S.ENGINEERING SERVICES INC. Job # 15492-02, #10 SCREW 350 S.Mi1liken,#A.ONTARIO,Ca91761 #6 SCREW Janos Boros P.E. PHONE (909) 97474150 Date 9- 4-2002 Reference: MCDERMOTT ENT.< W.W. Nelson > Description: Carport PULL Appendix Allowable Loads (lb) For Screws Per'ICBO ER=5202, LARR 25294 STEEL THICKNESS T. in. 1/4 - 14 SCREW #12 SCREW'" #10 SCREW #8; SCREW #6 SCREW PULL PULL PULL PULL PULL (GAUGE) SHEAR OUT SHE, .OUT SHEAR OUT SHEAR OUT SHEAR OUT ._1046 (12) 1102, ,591 884 497 660 575 534 363 436 320 .0747 (14) 920. 386' 829• 379 624 337 533 352 452 220 .0598 (16) 689 2-19 622 294 629 230 458 302 423 231 .0478 (18) 351 137 326 141 344, 155, 330 143' 251 138 0359 (20) 242 120 232 123- 225, '83 222 93 168 81