Loading...
10-0241 (CSCS)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253- BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number:00000241 Property, Address: 50991—WASHINGTON ST APN- 770 -020 -021 - Application description: NEW COMML - STORES & CUSTOMER SERVICE Property Zoning: NEIGHBORHOOD COMMERCIAL Application valuation: 270126 Applicant Architect or Engineer: Owner: TFG LQV C/O FOUNDATION GROUP 3857 BIRCH ST. STE NEWPORT BEACH, CA 9 Contractor: PRIMUS CONTRACTING, 1409 SO. 600 WEST, BOUNTIFUL, UT 84010 (760)341-4404 Lic. No.: 814726 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: ' 8/24/10 . ' LQPERMIT ------------------------------------------ ' LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with - I hereby affirm under penalty of perjury one of the following declarations: - . Section 7000) of Division 3 of the Business and Professionals Code, and my is 1r full force and effect. - _ I have and will maintain a certificate of. consent to self -insure for workers' compensation, as provided License C ass: B • License 4726 - for by Section 3700 of -the Labor Cde, for the performance of the work for which this permit is [� issued.. I have maintain insurance, as required by Section 3700 of the Labor ta: O 6 ontractor: and will workers' compensation Code, for the performance of the work for which this permit is issued. My workers' compensation - OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that) am exempt from the Contractor's State License Law for the Carrier TRAVELERS INDEM Policy Number DETUB8046B18909 - following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in theperformance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, - permit to file'a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State - and agree that, if I should become subject to the workers' co tion provisions of section.' License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the Labor Cod 4 shall forthwith comply wi provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500).: _ate:<JVJApplicant: - • (_) 1, as owner.of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered4or sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL - - Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND , and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000): IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN' improvements are not intended or offered for sale. If, however, the building or improvement is sold within - SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.l• APPLICANT ACKNOWLEDGEMENT (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of - conditions and restrictions set forth on this application:' .. ' property who builds or improves thereon, and who contracts for the projects with a contractorls) licensed 1 . Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). _ whose benefit work is performed under or pursuant to any permit issued as aresult of this application, 1 1 I am exempt under Sec. B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City _ - of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. _ • Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced • within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject ' - CONSTRUCTION LENDING AGENCY• - - permit to cancellation. - - I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the - I certify that I have read this application and state that the above information is correct: I agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.)• ' unt ordinances and state laws relating to building construction, and hereby authorize representatives_ city a�co of thh smy to enter upon the above-mentioned propert ins ction purposes. Lender's Name: �. �0 " ate: ature (Applicant or Agent): Lender's Address: LQPERMIT Application Number 10-00000241 ------ Structure Information SHELL.BUILDING ----- Construction Type . . . TYPE V, UNPROTECTED Other struct info . . . . CODE EDITION 2007/08 Energy FIRE SPRINKLERS YES MIXED-USE OCCUPANCY B/M OCCUPANT LOAD .00 PATIO SQ FTG 1792.00 1ST FLOOR SQUARE FOOTAGE 5579.00 2ND FLOOR SQUARE FOOTAGE .00 Permit BUILDING PERMIT., Additional desc . Permit Fee 1238.00 Plan Check,Fee 804.70 Issue Date Valuation . . 270126 Expiration Date 2/20/11 Qty Unit Charge Per Extension BASE FEE 639.50 171.0.0 3.5000 THOU BLDG 100;001-500,000 598.50 Permit .. ELEC-NEW COMMERCIAL Additional desc Permit Fee,' 162.42 Plan Check Fee 40.61 Issue Date Valuation .0 . Expiration Date 2/20/11 Qty Unit Charge. Per - Extension BASE FEE .15.00 . 7371,.00 ..0200 ELEC GARAGE OR NON-RESIDENTIAL 147.42' Permit GRADING PERMIT Additional desc. Permit Fee" 15:00 Plan Check'Fee .00 Issue Date . .. Valuation . . . . 0 Expiration Date 2/20/11 Qty Unit Charge Per Extension BASE FEE 15.00 ------------------ Permit MECHANICAL Additional desc . Permit Fee 186.50 Plan Check.Fee 46.63 Issue Date Valuation . . 0 LQPERMIT - . Application Number 10-00006241 Permit . . MECHANICAL Expiration Date 2/20/11 Qty Unit Charge Per Extension BASE FEE 15.00 6.00 16.50.00 EA MECH B/C.>3-15HP/>100K=500KBTU 99.00 6.00 .11.0000 EA MECH AH >lOK CFM 66.00 1.00 6.5000 EA MECH VENT FAN -. 6.50 Permit . . . PLUMBING :Additional desc . Permit Fee 91.50 Plan .Check Fee 22.88 Issue Date . . . . Valuation 0 Expiration Date 2/20/11 Qty Unit Charge Per Extension BASE FEE 15.00 . 3.00 6.0000 EA PLB FIXTURE 18.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 4.00 6.0000 EA, PLB ROOF DRAIN 24.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.'0000 'EA 'PLB LAWN SPRINKLER SYSTEM 9.00 ---------------------- ------------------------------------------ ------ - Special Notes and Comments Special SHELL BUILDING 7,371 SF GROSS (5,579 SF COND. 1,792 COVERED PATIO) "B" OR "M" OCCUPANCY. TYPE V-B CONSTRUCTION. 2007 CODES, 2008 ENERGY. **PERMIT DOES NOT INCLUDE TEMPORARY POWER, BLOCK. WALLS, TRASH ENCLOSURE AND SITE LIGHTING.** 2008 DIF. Other Fees ACCESSIBILITY PLAN REVIEW 80.47 ART IN PUBLIC PLACES-COM 1330.63 BLDG STDS ADMIN'(SB1473) 9.00 DIF CIVIC CENTER - COMM 3564.86 ENERGY REVIEW FEE 80.47 DIF FIRE PROTECTION-COMM - 2008.44 STRONG MOTION (SMI)- COM 56.73 DIF STREET MAINT FAC-COMM. 1405'.9.1 DIF TRANSPORTATION .- COMM 31510.21 Fee summary Charged Paid Credited Due Permit Fee Total 1693.42 .00 .00 1693.42 Plan.Check,Total 914.82 750.00 .`00 164.82 BUILDING ENERGY ANALYSIS REPORT PROJECT: ` ` , LA QUINTA VILLAGE NWC Calle Tampico & Washington St-. La Quinta; CA 92253 Project Designer:;_.. Grist Associates C e TY OF LA QUI NTA 1450 West Colorado BIudBUILDINGI SAFETY DEPT. . Pasadena, -,CA 9110 APPROVED (626) 304-0733 FOR CONSTRUCTION' r DATE 7 �5 ?.��D gY r✓�''.. Report Prepared b __ Wentien Huang P. E. V Z� 1837 Via Del Rey _ South Pasadena, CA 91030; (213)926-6236 i F�R)�M N ly idrvlNQ 1 P. p r 1 Job Number: , JUN 17 2010 ` 06-119.00 J , Date: 4/18/2010 The EnergyPro computer program has been used to perform the calculations summarizer/ in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft. LLC — www.energysofLcom. EnergyPro 5.O by EnergySoR User Number: 3151 RunCode: 2010.04-18T13:18:4 • ID: 06-119.00 i TABLE OF CONTENTS Cover Page . 1 Table of Contents 2 Form ENV -1-C Certificate. of Compliance 3 Form ENV -3-C Overall Envelope TDV Approach 8 Form ENV -4-C Minimum Skylight Area Worksheet 14 Form ENV -MM Envelope Mandatory Measures 16 Form LTG -1-C Certificate of Compliance 17 Form LTG -3-C Indoor Lighting Power Allowance 21 'Form LTG -MM -Lighting Mandatory Measures 22 Form OLTG-1-C ,Certificate of Compliance 23 Form SLTG-1=C Sign Lighting Compliance 27 Form MECH-1-C Certificate of Compliance 28 Form MECH-2-C Air & Water System Requirements 34 Form MECH-3-C Mechanical Ventilation 36 �{ Form MECH-4-C HVAC Misc. Prescriptive Requirements 37 Form MECH=MM Mechanical Mandatory Measures 39 HVAC System Heating and -Cooling Loads Summary 40 EnergyPro 5.0 by EnergysoR Job Number: ID: 06-119.00 User Number: 3151 CERTIFICATE�OF COMPLIANCE > 4) ENV C: ,1 ANDFIELD INSPECTION ENERGY, CHECKLIST _ ' '. Project Name a Date LA'QU INTA-VILLAGE :. 4%18/2010.. Project Address ;• :: - Climate Zone - Total Cond• Floor Area I Addition Floor Area: NWC;Galle Tampico., & Washington St = La-Quinta '' 15 .' 5;579 n/a , 'GENERAL• INFORMATION, Buildin T e:• ® Non)esidential ❑ High -Rise Residential. O.- Hotel)Motel'GuestRoorn Relocatable Public School . ❑ Schools (Public School).. p f3td - - y, . ®;•. Conditioned Spaces ❑. 'Unconditioned Spaces ❑ Skylight Area -for. Large,Enclosed Space Z 8000 ft2 (If checked includ6'the'ENV-4C with'submittal) Phase of Construction: ',. ®''. New Construction p Addition .El'. Alteration Approach of Compliance:- O ' Component.. 't0 -Overall Envelope ❑' Unconditioned _(file affidavit) ; Front Orientation: N, E, S, W or in Degrees FIELD' INSPECTION ENERGY CHECKLIST, - ; 7. t y �. .. r- y W > 7 mom. ;, o, tt CERTIFICATE�OF COMPLIANCE > 4) ENV C: ,1 ANDFIELD INSPECTION ENERGY, CHECKLIST _ ' '. Project Name a Date LA'QU INTA-VILLAGE :. 4%18/2010.. Project Address ;• :: - Climate Zone - Total Cond• Floor Area I Addition Floor Area: NWC;Galle Tampico., & Washington St = La-Quinta '' 15 .' 5;579 n/a , 'GENERAL• INFORMATION, Buildin T e:• ® Non)esidential ❑ High -Rise Residential. O.- Hotel)Motel'GuestRoorn Relocatable Public School . ❑ Schools (Public School).. p f3td - - y, . ®;•. Conditioned Spaces ❑. 'Unconditioned Spaces ❑ Skylight Area -for. Large,Enclosed Space Z 8000 ft2 (If checked includ6'the'ENV-4C with'submittal) Phase of Construction: ',. ®''. New Construction p Addition .El'. Alteration Approach of Compliance:- O ' Component.. 't0 -Overall Envelope ❑' Unconditioned _(file affidavit) ; Front Orientation: N, E, S, W or in Degrees FIELD' INSPECTION ENERGY CHECKLIST, - ; 7. t y �. .. r- y W > 7 mom. ;, o, �m c a o LT70i w + Ta /ID. Assembly Frame'T e s via N O z' U >' L) LL-. w a v. Waif ' Wood Framed ' 338 .' , -''"(N) R-13 • : . 0.0 ❑' `: New • ' .: 0 ® D Wall - - s Wood Framed 288 ;' (I R=13 A:0 ❑ New ", KE FJE1 Wall Wood Framed ,. '' - 984 (S). • , R-13 ' . 0.0 ❑ ,:; New D O O Roof -` UVood Framed Attic ° 4,401 (N) - R-30 0.0 ❑ New Slab Unheated Slab on -Grade 4,401 :.(N) , , None 0.0 ❑; New .' 0 O O Wall ,, Wood Framed, 106 (N) R-13 0:0 ❑ New Wall Wood Framed 188 (E) R-13 00 ❑: New I ❑p Wall Wood Framed ., 139 (S) R43 {': .-0:0 ❑ New O„R O.: ❑ 1:' indicate.the identifyi' 'name of the frame type (i.e. Wall -1: Ceiling -f; Roof -1', and Floor -..1.)'. ! ', 2. Indicate type of_AssemblyType'such as Wood 2x4or LW,CMU.8". For additional other -assembly types see Reference Joint Appendix,-JA4 t_ " 3. If furring is ch"ecked refer to ENV-2C,Mass and- Furring Strips Construction worksheet., . 4. Indicate furring,R-value when furred wall are being used • f 5. Indicate Status of fenestration (New, Existing, or lJpgrade). 6': Indicate Speciai Feature.bn Page'2 of the Inspection Checklist Form below ;7. If Pail, then describe on Page 2 of;the,lnspection Checklist Form and take appropriate, action to correct. VerifybUilding.plans if,necessary FENESTRATION_ SURFACE- DETAILS., d.yN o., y O. d enestrationWooo>Tag/IDeZ 17312111 via NOZ os: �� N 2¢, N 0.,' 0vi:i+i affiRM 1 "} Window 729 (N):' 0:390 NFRC = 0.370 NFRC 0 New ❑ ❑ 0 2; • Window 63 (N) 0.770 NFRC- 0:400 NFRC' ❑ New.' ® D 0 3 • Window _�• .. .. 339 (W). 0:390 NFRC` 0.320 NFRC : 0;' New ❑ D 4 Window- 21 '(W). 0:770 NFRC_.' 0.400 NFRC.,- .❑” New ® ❑��: 5 Window 460 • (Ef. 0.390 NFRC 0.370 NFRC", ' 0 ew• New,- 6 6 Window 113 (S), 0.390 NFRC 0.370 NFRC; 0 New El , 131,11 } ❑ El ❑ O v ` o o A. -Indicate the identifying name of the frame type (i.e. Window #1). 2. Indicate type of'construction.Type such, Window, Glass Door; Curtain,wall, Skylight, & other. 3. Indicate if the'efficiency values are from the NFRC Label Certificate or from the CECPefault.Values. `Enter. NFRC'or CEC (FC -1 and FC=2). -, .4.1ndicate Status of fenestration (New, Existing or Upgrade)._. 5. Indicate Special Feature'on Page 2 of•the Inspectiori.Checklist Form below -take 6. If Fail then describe on Page 2 of.the Inspection'Checklisi Form and appropriate action to correct. Verify bwldingplans if necessary:'; EnergyPro5:0 by EnergySoft , User Number., 3151 `.- RunCode: 2010=04-1.8T13:18:47 /D:.06-119.00 +' '_Page 3 of.41 _ s 4 F t ;. � ,. �Y�v - � Y � ' � � U 1 (� �' k; � � iii- � .l i .� _ � .. .. .. r ^.4 . - ,i _ � � _ .i� � _ _ CERTIFICATE OF COMPLIANCE (Part 2 Of 4),:. ENV -1 C- •. _. AND FIELD INSPECTION ENERGY CHECKLIST , "- . , Project.Name :.• :... "Date ... LA:QUINTAVILLAGE 4/18/2010 _• .ROOFINGPRODUCT COOL ROOFS (Note.if the roofing product is not CRRC'certified, this compliance approach cannot be used) Go to Overall Envelope Approach or Performance -A roach. ,. CHECK APPLICABLE BOX'BELOW IF EXEMPT FROM THE ROOFING'PRODUCT "COOL=ROOF" REQUIREMENTS:Pass F IIW, wWN/-A ❑ Roofing compliance not required in Climate'Zones.l and16'with a,Low-Sloped.-.2.12 pitch or.less. . 100 ,. k Roofing compliance not -required in Climate Zorie 1 with Steep Sloped with less than,5 Ib/ft2: Greater than 2:12 pitch.mm Low - .sloped Wood framed roofs, in Climate Zones 3:and 5 are exempted. Solar reflectance.and thermal emittance or l] ' SRI that have a U=factor of 0,039 or lower, see Opaque ue Surface Details roof assembly, Colurrin H of ENV -2C. • _ =opt= The roof: areacovered ❑ by, building integrated, photovoltaic panels and "building -integrated solar thermal panels are-ezem" ted.'Solar reflectance and thermaf emiitarice or SRI, seespreadsheet-calculator at,www.ener .ca: ov/title24/ 0 . Roof constructions that have thermal mass over the roof membrane with a weight of at'least 25,1b/ftare exempt from •' - ahe Cool Roof criteria below. High-rise residential buildings and hotels and motels with low -sloped roofs in Climate Zones 1 through 9, 12 and 16 are . exempted from the low -sloped idofin6 criteria. 1. If Fail then describe on this page'of the Inspection Checklist Form and take appropriate action 6correct. Verify building plans if necessary CRRNumrber'ct ID Roof Stz: 2 Pry b/fC't Weighf Product Aged Solar Thermal, Special P 51b/fe T eZ-:. Reflectarice3 , ,Errmitance ' , SRIS Features Pass FaiP Iffm KIP HIBM 13 03 13 nko "El - ; o o ❑- 131 ffo El ••t. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at www.coolroofs.ora/products/search.php 2. Indicate the type of product,is being used for the roof top, i.e. single -ply roof; asphalt roof, metal roof, etc. 3. If the Aged Reflectance is not available in the Cool Roof Rating. Council's Rated Product_ Directory then use the -Initial Reflectance value from the same directory.and use the equation (0:2+0.7(p,rona, `q-2) to obtain a calculated aged value. Where p is the Initial Solar Reflectance'from'the Cool Roof Rating Council's Rated Product Directory: 4:'Check box if the Aged Reflectance is a calculated value using the equation above. 5:;The SRI value needsto be calculated from a spreadsheetcalculator at http://www.energv.da.gov/title24/ 6.' Indicate Special Feature -on Page 2 of the Inspection Checklist Form below. 7. If Fail then, describe' .onJthis ` age of the Inspection Checklist'Form and take's ro riate'action to correct.; Verif building plans if necessary. To apply Liquid Field Applied Coatings, the.coating must-be'applied across.the entire.roof'surface and meet the dry, mil thickness or.coverage recommended by the coatings manufacturer and meet minimum performance requirements listed in §118(1)4': Selectthe applicablecoating:- ❑ Aluminum -Pigmented Asphalt : Roof Coating ; -1Cement-Based Roof Coating ❑ Other. SPECIAL -FEATURES, INSPECTION'CHECKLIST The local enforcement agency should pay special' attention to the items specified in this checklist. These items require special written justification, and; 'documentation, and special verification. The local enforcementagencydetermines the adequacy of the justification, and may reject a building or deli n'that otherwise com lies.based on the.ade Lac of the special . justification and documentation, submitted. '. Discre •artcies: _ f • ILEriergyPro 5.0 by Ener Soft User Number 3151 RunCode: 2010-04r18T13:18.47- .' , ID 06-119.00 ' Pae 5 of 41. CERTIFICATE OF COMPLIANCE (Part 3 of 4) ENV -1 C AND FIELD INSPECTION ENERGY CHECKLIST Project Name LA QUINTA VILLAGE Date 1411812010 Required Acceptance Tests Designer: This form is to be used by the designer and attached to the plans. Listed below is the acceptance test for Envelope Fenestrations system. The designer is required to check the acceptance tests and list all the fenestration products that require an acceptance test. If all the site -built fenestration of a certain type requires a test, list the different fenestration products and the number of systems. The NA7 Section in the Appendix of the Nonresidential Reference Appendices Manual describes the test. Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Enforcement Agency: Systems Acceptance. Before Occupancy Permit is granted for a newly constructed building or space or whenever new fenestration is installed in the building or space shall be certified as meeting the Acceptance Requirements. The ENV -2A form is not considered a complete form and is not to be accepted by the enforcement agency unless the boxes are checked and/or filled and signed. In addition, a Certificate of Acceptance forms shall be submitted to the enforcement agency that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of §10-103(b) of Title 24 Part 6. The field inspector must receive the properly filled out and signed forms before the building can receive final occupancy. A copy of the ENV -2A for each different fenestration product line must be provided to the owner of the building for their records. Test Description ENV -2A Test Performed By: Fenestration Products Name or ID Area of like Building Envelope Requiring Testing or Verification Products Acceptance Test Milgard Classic Low -E Vinyl 1,641 El Milgard MIMI Or Low -E 84 0 ❑ 13 13 13 11 13 13 EnergyPro 5.0 by EnergySoft User Number: 3151 Run Code: 201 0-04 1 8 713:18:47 ID: 06-119.00 Page 6 of 41 0 CERTIFICATE OF COMPLIANCE (Part 4 of 4). ENV -1C AND FIELD INSPECTION ENERGY CHECKLIST Project Name Date LA QUINTA VILLAGE 4/18/2010 Project Address Climate Zone Total Cord. F oor Area Addition Floor Area NWC Calle Tampico & Washington St La Quinta I CA Climate Zone 15 509 1, n/a Documentation Author's Declaration Statement &a. I certify that this Certificate of Compliance documentation is accurate and complete. Signal/e/jt Name Wentien Huang P.E. Company Date . 4/18/2010 Address EA # 1837 Via Del Rey CEPE # !% CltyiState/Zip South Pasadena. CA 91030 Phone (213)926-6236 The Principal Envelope Designer's Declaration Statement • I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the envelope design.- . a • This Certificate of Compliance identifies the envelope features and performance specifications required for compliance with Title -24, Parts 1 and 6 of the California Code of Regulations. • The design features represented on this Certificate of Compliance are consistent with the information provided to document this design on the other applicable compliance forms. worksheets. calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Name John Grist Signature Company Grist Associates Date Address 1450 West Colorado Blvd. License # City/State/Zip Pasadena. CA 91105 Phone (626) 304-0733 Envelope Mandatory Measures Indicate location on building plans of Mandatory Envelope Measures Note Block: INSTRUCTIONS TO APPLICANT ENVELOPE COMPLIANCE & WORKSHEETS (check box if worksheet is included For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms. please refer to the 2008 Nonresidential Manual published by the California Energy Commission. m ENV -1 C Certificate of Compliance. Required on plans for all submittals. O ENV -2C Use with the Envelope Component compliance approach. Optional on plans. 0 ENV -3C Use with the Overall Envelope compliance approach. Optional on plans. m ENV -4C Use with Prescriptive compliance for the minimum skylight requirements for large enclosed spaces in climate zones 2 through 15. Optional on plans. EnergyPro&0 by EnergySoft User Number 3151. RunCode: 2010-04-18T13:18:4 /D: 06-119.00 Page 7 of 41 0 u : OVERALL ENVELOPE TDV ENERGY APPROACH-- (Part 1 •of 6) ENV -3C Project Name 713ate LA QUINTA VILLAGE 4/18/2010 WINDOW RATIO CALCULATION for ALL WALLS 1,884 ft2 Display Area 1,507 rig 40% of Gross Exterior Wall Area 1,884 ft2 Maximum Standard Area 1, 725 ft2. Proposed Area If the proposed Window Area is greater,than the Maximum Standard Area, then -the envelope component method may not be used. 4b.78 _ See RSHG in Table 143-A, 143- E. Window Wall Ratio = (Row D) Divided by (Row B) = B, or 143-C WEST WINDOW RATIO CALCULATION A. Total linear display perimeter 314 ft X 6 ft = B. Total Gross Exterior Wall Area 3.768 ft2 X 0.40 = C. Enter Larger of A or B D. Enter Proposed Window Area F. West Linear Display 54 ft X 6 ft = G. West Exterior Wall Area 648 ft2 X0.40. _ H. Enter Larger of F or G I. Enter Proposed West Window Area 324 ft2 West Display Area 259 ft' 40% of West Exterior Wall Area 324 ft2 Maximum Standard West Area 360 ft2 Proposed West Window Area If the proposed West Window Area is greater than the Maximum Standard West Area, then the envelope component method may not be used. 5556 See West RSHG in Table 143-A, . J. Window Wall Ratio = (Row 1) Divided by (Row G) 143-13, or 143-C COMBINED AREA FOR NORTH, EAST AND SOUTH WALLS K. - N/E/S Display Perimeter (A Minus E) 260 ft X 6 ft' _ L. N/E/S Exterior Wall Area (B Minus G) 3,120 ft2 X 0.40 = M. Enter Larger of K or L N. Proposed N/E/S Window Area (D Minus 1) 1,560 ft2 N/E/S of West Exterior Wall. Area 1,248 ft2 40% N/E/S Area 1,248`. ft2 Maximum Standard N/E/S Area 1,365 ft21 Proposed N/E/S Area WINDOW ADJUSTMENT O. If D_> C and/or if I > H, proceed to the calculation steps 1 for all walls or 2 for west wall. If not, go to the skylight area test on page 6. 1. If'D >'C: Use the calculated Window Adjustment Factor (WAF) for all walls. PROPOSED WINDOW MAX. STANDARD AREA AREA WINDOW from C from D ADJUSTMENT FACTOR Go to Page 6 to calculate Adjusted Area 2. If I > H': Calculate one Window Adjustment Factor (WAF) for the West wall. MAX. STANDARD WEST PROPOSED WEST AREA WEST WINDOW AREA from H from 1 ADJUSTMENT FACTOR 324 - 360 = 0.900 MAX. STANDARD AREA PROPOSED. AREA WEST WINDOW from C from D ADJUSTMENT FACTOR 1,248 _ 1,3651 1 Go to Page 6 to calculate Adjusted Area Ener Pro 5.0 by Ener Soft User Number: 3151 Run Code: 2010-04-18T13:18:4 ID: 06-119.00 Page 8 of 41 OVERALL ENVELOPE TDV ENERGY APPROACH (Part 2 of' 6) ENV -3C. Project Name Date LA QUINTA VILLAGE.. 4/18/2010 SKYLIGHT. RATIO CALCULATION §143(b) Actual Gross Roof Maximum Allowed Standard. ' Area Skylight Area 279 ft, A. If Atrium/SkylightHeight is 5 55 ft; or 5,579 ft2 X 0.05 = B. . If Atrium/Skylight Height is > 55 ft ft2 X 0.10 - ft2 C. Proposed Skylight Area 0 It D. Skylight Ratio = Proposed, Skylight Area (Row C) Divided by Actual Gross Roof Area = ao % SRRP,°P E. Maximum Allowed Skylight Roof Ratio = Maximum Allowed Standard Skylight Area (Row A or B) Divided by Total Gross Exterior Roof Area _ - 5 % SRRsTo IF THE PROPOSED SKYLIGHT AREA IS GREATER THAN THE STANDARD SKYLIGHT AREA, PROCEED TO THE NEXT CALCULATION FOR THE SKYLIGHT AREA ADJUSTMENT. IF NOT, GO TO PAGE 3 OF 6::-' SKYLIGHT AREA ADJUSTMENT IF F > D, Proceed To Calculation Step 1 Step 1. Calculated the Skylight Adjustment Factor (WAF). STANDARD PROPOSED SKYLIGHT SKYLIGHT ADJUSTMENT SKYLIGHT AREA AREA IF E = O'ENTER 1 FACTOR SAF `, CARRY THE WINDOW ADJUSTMENT FACTOR (SAF) TO PAGE 6 OF, 6 TO CALCULATE THE ADJUSTED AREA 4 Ener Pro 5.0 by Ener Soft User Number: 3151 Run Code: 2010-04-18T13:18:4. 17 06-119.00 Page 9 of 41 OVERALL ENVELOPE TDV ENERGY APPROACH (Page 3 of 6 ENV -3C Project Name LA QUINTA VILLAGE Date 4/18/2010 TDV for the Standard Desi jn Building, See Reference Nonresidential Appendix NA5-2 Occupancy Type and Coefficients Tables m Nonresidential, See Table NA5-3 ❑ 24 -Hour Use, See Table NA5-4 12 Retail, See Table NA5-5 Climate Zone: 15 A B C D E F G H I J K L Assembly Type' Orientation Number Of Like Assembly Type' Roofs or Floor Mass Type' Exterior Surface Area Criteria Coefficients for > > ' U -factor SHGC VT Standard TDV Enerqy8 U -factor° SHGC' VT6 . Cs,'/ Cssu Csrr Wall N 1 Light 338 0.042 201.13 2,855 Window N 1 604 0.470 0.400 0.480 54.49 303.70 -20.19 82,989 Window N 1 42 0.470' 0.400 0.480 54.491 303.70 -20.19 5,771 Wall W 1 Light 324 0.042 201.13 2,737 Window W 1 305 0.470 0.310 0.372 51.41 713.09 -30.12 71,398 Window W 1 19 0.470 0.310 0.372 51.41 713.09 -30.12 4,423 Wall S 1 Light 984 0.042 201.13 8,312 Roof 1 Light 4,401 0.039 191.53 32,874 Wall N 1 Light 106 0.042 253.96 1,131 Window N 1 125 0.470 0.400 0.480 17.76 123.50 -5.01 6,918 Window N 1 21 0.470 0.400 0.480 17.76 123.50 -5.01 1,162 Wall E 1, Light 188 0.042 253.96 2,005 Window E 1 460 0.470 0.3101 0.372 18.73 270.91 -2.97 42,173 Wall S 1 Light 139 0.042 253.96 1,483 Window S 1 113 0.470 0.310 0.372 17.55 311.65 -7.90 11,517 Roof 1 Light 1,178 0.039 1 219.81 10,099 Sum of Total Standard Design 287,847 1. Indicate type of assembly for the Envelope (e.g. Wall, Floor, Roof, Window, Skylight & Door). One assembly type for each row. 2. Indicate the orientation for walls, doors & windows. 2A. Note: Grouping of like assemblies in the same orientation is allowed. Indicate the number in column C. 3. For Roofs & Floors, the categories are; For Walls, the catergoies are; light (HC < 7), medium mass (7 5 HC,15), and heavy mass (HC 2:15). 4. Standard Design Ll -factor are from Table 143-A, B or C. 5. Standard Design SHGC are from Table 143-A, B or C. Enter V if not applicable. Note: Not all vertical windows have an overhang then assume SHGC as value entered. 6. To calculate the fenestration standard design VT in Column H. Multiply Column G by 1.2. 7.. Coefficients for; Ll -factor (Cs,,,,), SHGC (Cs;j), and VT(Cs,a, can be found in Table NA5-2, through Table NA5-5 of the Reference Nonresidential Appendices NA5. The Coefficient for SHGC and VT are only entered for the fenestration products. Enter V when not applicable. 8. Calculate the TDV Standard Design for for each Envelope Aassembly Type: TDVstd = Column C x [Column E x ((U -factors; x Cs„) + (SHGCsi x Cu) + (VTs; x Csi,))) for each Assembly Type. See Nonresidential Manual Examples in Section 3.7 for details! EnergyPro5.O by EnergySoft User Number. 3151 - RunCode: 201 0-04-1 8 713:18:47 ID: 06-119.00 Pae 10 of 41 OVERALL ENVELOPE TDV ENERGY APPROACH (Page 4 of 6 ENV -3C Project Name LA QUINTA VILLAGE Date 4/18/2010 TDV for the Proposed Design Building, See Reference Nonresidential Appendix NA5.3 Occupancy Type and Coefficients Tables m Nonresidential, See Table NA5-3 ❑ 24 -Hour Use, See Table NA5-4 ® Retail, See Table NA5-5 Climate Zone: 15 A B C D E F G H I J K L M Assembly Type' Orientation Number Total. Coefficientsfor Of Like Exterior> > >Overhang' Assembly Surface Criteria U -factor RSHGC VT Cool Roofs Type2A Area U -factor° SHGC5 VTS Csu,i CS,, Ct,i MCR Mo„ Proposed TDV Ener 10 Wall N 1 3381 0.102 201.13 6,934 Window N 1 604 0.390 0.370 0.500 54.49 303.70 -20.19 0.842 63,905 Window N 1 42 0.7701 0.400 0.500 54.491 303.70 -20.191 1.000 6,440 Wall W 1 288 0.102 201.13 5,908 Window W 1 339 0.390 0.370 0.500 51.41 713.09 -30.12 0.4691 43,640 Window W 1 21 0.770 0.400 0.500 51.41 713.09 -30.12 1.000 6,505 Wall S 1 984 0.102 1 201.13 20,187 Roof 1 4,4011 0.031 191.53 2.143 55,998 Wall N 1 106 0.102 253.96 2,746 Wndow N 1 125 0.390 0.370 0.500 17.76 123.50 -5.01 0.668 4,369 Wndow N 1 21 0.770 0.400 0.500 17.76 123.50 -5.01 1.000 1,272 Wall E 1 188 0.1021 253.961 4,870 Window E 1 460 0.390 0.370 0.500 18.73 270.91 -2.971 0.181 11,002 Wall S 1 139 0.102 253.96 3,601 Window S 1 113 0.390 0.370 0.500 17.55 311.65 -7.90 1 0.320 4,491 Roof 11 1,178 0.031 1 219.81 2.116 16,985 Total Proposed Design 258,853 Pro osed <_ Standard YES 1. Indicate type of assembly for the Envelope (e.g. Wall, Floor, Roof, Window, Skylight & Door). One assembly type for each row. 2. Indicate the orientation for walls, doors & windows. 2A. Note: Grouping of like assemblies in the same orientation is allowed. Enter the number in column C. 3. Indicate the Exterior Surface Area of the Assembly for that one assembly or if like assemblies then the total surface area of all assemblies in the same orientation. 4. Standard Design 1 -1 -factor are from Table 143-A, B or C for the appropriate assembly type. 5. Standard Design SHGC are from Table 143-A, B or C. Enter "0" if not applicable. Note: Not all vertical windows have an overhang then assume SHGC as value entered. 6. To calculate the fenestration standard design VT in Column G. Multiply Column F by 1.2. 7. Coefficients for; LI -factor (Cs,,,i), SHGC (Cs.,,), and VT (Cs,,,), can be found in Table NA5-2, through Table NA5-5 of the Reference Nonresidential Appendices NA5. The Coefficient for SHGC and VT are only entered for the fenestration products. Enter "0" when not applicable. 8. Calculate the Cool Roof, McR, first by using the next page (Page 5 of 6). Enter the value in the Proposed Column K. 9. Calculate the Overhang MoH, on the next page (Page 5 of 6). Enter the value in the Proposed Column L. 10. The Proposed TDV energy use for all assemblies other than roofs must be equal to or less than Standard TDV in Page 3 of 6. TDVP = Column D x [(U factor x Cs„) + (SHGCP x CSS; x MOH) + (VTP x Cs,)). Enter calculated value in Proposed Column M. 11. For Cool Roof, TDVPR= Column D x CRO x URI x MCR, . Enter the calculated value in Column M. EnergyPro 5.0 by EnergySoR User Number.' 3151 Run Code: 2010-04-18T13:18:47 ID: 06-119.00 Page 11 of 41 OVERALL ENVELOPE TDV ENERGY APPROACH (Part 5 of 6) ENV -3C Project Name LA QUINTA VILLAGE Date 4/18/2010 Cool Roof multiplier (MCR) Occupancy Type and Coefficients Tables [a Nonresidential, See I Table NA5-3 ❑ 24 -Hour Use, See ® Retail, See Table NA5-5 Table NA5-4 Climate Zone: 15 Coefficients of Calculation A B C D E F G Reflectance Emittance Proposed Aged Solar Reflectance Standard Aged Solar Reflectance' Proposed Thermal Emittance Standard Thermal Cool Roof Emittance Multi lien -2.540 -0.900 0.10 0.55 0.75 0.75 2.143 -2.480 -1.000 0.10 0.55 0.75 0.75 2.116 Enter multiplier in Page 4 of 6, Column J. Where: Standard design values for Solar Reflectance and Thermal Emittance. Except from Table NA5-2 Standard Aged Standard Thermal Solar Reflectance Emittance Column D Column F Low -Rise, Low -Sloped, CZ2 through CZ15 0.55 0.75 Low -Rise, Low -Sloped, CZ1 through CZ16 0.10 0.75 Hi h -Rise, Low -Sloped, CZ10 through CZ15 0.55 0.75 High -Rise, Low -Sloped, CZ1-9 through CZ16 0.10 0.75 Steep -Sloped, CZ2 through CZ15 0.25 0.75 Steep -Sloped, all other 0.10 0.75 1. Proposed Aged Design Solar Reflectance; Paged prop = 0.7 X (Pinit prop + 0.06). Where (P;nit Prop) reflectance value is found in the CRRC Directory. Enter results of the Cool Roof Multiplier equation in footnote 2. 2. Cool Roof Multiplier MSR i = 1 + CRei X (Paged prop - Paged std) + CEmit X £ ro - Fstd or 1+ Col A X Col C - Col D + Col B X Col E - Col F Overhang Multiplier MOH Occupancy Type and Coefficients Tables ® Nonresidential, See I Table NA5-3 ❑ 24 -Hour Use, See Table [0 Retail, See Table NA5-4 NA5-5 Climate Zone: 15 Coefficients of Fenestration Overhang Calculation A B C D E F G 1. 2w Horizontal Projection Projection Projection Orientation Factor' Factor' ft2 Vertical Distance flz Projection Overhan Factorz Multiplier N -0.310 0.140 8.0 10.1 0.792 0.842 W -0.710 0.050 8.0 10.1 0.792 0.469 N -0.720 0.380 8.0 10.1 0.792 0.668 E -1.920 0.910 6.0 10.1 0.594 0.181 S -2.130 1.040 4.0 10.1 0.396 0.320 Enter multiplier in Page 4 of 6 Column K. 1. Where a, and bi are he coefficients for the overhang projection factor (see tables) and is climate zone dependent. 2. PF = HN (Horizontal (H) projection of the overhang from the surface of the window in feet, but no greater than V and the Vertical (V) distance from the window sill to the bottom of the overhang, in feet.) Enter results in Column F. 3. MOKI = 1+ a, X PF; + bi X PF12. Enter results in Column G. EnergyPro 5.0 by Energ So User Number: 3151 RunCode: 2010-04-18713:18:47 ID: 06-119.00 Page 12 of 41 OVERALL ENVELOPE TDV ENERGY APPROACH (Part 6 of 6) ENV-3C Project Name LA QUINTA VILLAGE Date 4/18/2010 WINDOW AREA ADJUSTMENT CALCULATION A B C D E F G Wall Name e.. Wall-1, Wall-2 Orientation Gross Area Window Door Area Area • Window Adjusted Adjustment Window Factor . Area From Pagel) D X E • Adjusted Wall Area B — F + C N' E I S W Exterior Wall-North ✓❑ ❑ ❑ ❑✓ ❑ ❑ 1:1, ❑ ❑ ❑ ❑ El - ❑ ❑ ❑ ❑ ❑ ❑ ❑, ❑ ❑✓ ❑ 13- ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ o ❑ ❑ 1:1. ✓❑ ❑ ❑ El ❑ ❑ +❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑✓ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ o ❑ ❑ 984 0 646 1.000 646 338 Exterior Wall-West 648 0 3601 0.900 324 324 Exterior Wall -South 984 0 0 1.000 0 984 Exterior Wall - North 252 0 146 1.000 146 106 Exterior Wall - East 648 0 460 1.000 460 188 Exterior Wall - South 252 0 113 1.000 113 139 • 3,768 0 1,725 1,689 2,079 Totals: SKYLIGHT AREA ADJUSTMENT CALCULATIONS A B C D E F Roof Name e.. Roof-1, Roof-2 Gross Area Skylight Area Skylight Adjustment Factor From Pae 1 Adjusted Skylight Area C X D Adjusted Roof Area B — E Totals: Ener Pro 5.0 by EnerqySoft User Number: 3151 Run Code: 2010-04-18T13:18:4 ID: 06-119.00 Pae 13 of 41 MINIMUM SKYLIGHT AREA WORKSHEET (Part 1 of•3) ENV -4C Project Name Date LA QUINTA VILLAGE 4/18/2010 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES definition in §131(c),- requirements in §143c ✓ 0 This.worksheet applies to buildings with three or fewer stories, in climate zones 2 through 15, having an enclosed space > 8,000 ftZ that is directly under a roof, with a ceiling height > 15 ft and the -exception below does not apply. Go to Step 1. • Name or reference of Large Enclosed Space on building plans • Proposed daylight area is indicated on page of the.building plans. ✓ ❑ Skylights not required as fully designed lighting system on page of building plans has general lighting power density of < W/ftZ, which is less than 0.5 W/ft2 Note: this exemption applies only to buildings with a fully designed lighting system. This exception does not apply to core & shell buildings. STOP HERE IF THIS BOX IS CHECKED. Space is exempt from minimum skylight area requirement. NOTE: The minimum skylight area requirements can be met using skylit daylight areas, primary sidelit daylight areas, or a combination of both. Use Step 1 below if using skylit daylight areas for compliance. Use Step 2 below if using sidelit daylight areas for compliance. Use Step 3 below to add together skylit daylight and primary sidelit daylight areas. Step 1 Calculate if Proposed Skylit Daylight Area is greater than or equal to Minimum Daylight Area. ❑ Criterion 1: Check if Total Proposed Skylit Daylight Area is greater than or equal to Minimum Daylit Area. (C >_ B) If Criterion 1 is checked, skip step 2. Go to Step 3. Floor Area of proposed design large enclosed space A 4,401 fe Space floor area Minimum Daylight Area = 0.5 x Floor Area (A) B 2,201 ftZ Minimum Daylight Area = 0.5 x (A) Proposed design skylit daylight area in accordance with C 0 ft Proposed Skylit Daylight Area §131(c)1D and as shown on the plans. Step 2 Calculate if Proposed Primary Sidelit Daylight Area is greater than or equal to Minimum Daylight Area ❑ Criterion 2: Check if Total Proposed Skvlit Davlioht Area is eaual to or areater than Minimum Davlit Area (D >_ B). Primary sidelit daylit area determined in accordance with §131(c)1 B and as shown on the plans D 0 ftZ Proposed Primary Sidelit Daylight Area Step 3 Confirm that Proposed Primary Sidelit + Skylit Daylight Area is greater than or'equal to Minimum Daylight Area ❑ Criterion 3:'Check if Total Proposed Davliaht Area is areater than or eaual to Minimum Davlit Area (Ea Bl: Total Proposed Daylight Area = Skylight Area + PrimaryE Sidelit Area Add C + D and enter into E 0 ftZ Total Proposed Daylight Area If Criterion 3 is checked, complete both Steps 4 & 5 on Page 2 ❑ If Criterion 3 is unchecked. Space FAILS, not enough daylight area, do not continue.. + Ene Pro 5.0 by EnerqySoft User Number: 3151 RunCode: 2010-04-18T13:18:4 ID: 06-119.00 Pae 14 of 41 MINIMUM SKYLIGHT AREA WORKSHEET (Part 2 of 3) ENV -4C Project Name Date LA QUINTA VILLAGE 1 4/18/2010 SKYLIGHT AREA FOR LARGE ENCLOSED SPACES 143c Step 4 — If using SKYLIGHT to comply with the minimum skylight area requirements, calculate compliance with minimum skylight area using Step 4a, or compliance with minimum effective aperture using Step 4b. Also verify compliance with skylight haze criteria is met in Step 4c . Step 4a — If Complying with minimum skylight area: ❑ Criterion 4a: Check if Proposed Skylight Area is equal or greater than Minimum Skylight Area (H z G). Proposed Skylight Daylight Area from cell (C), Step 1, on ENV -4C (Page 1 of 3) F ft Proposed Skylight Daylight Area Minimum Skylight Area = Skylight Area (F) X 0.033 G fe Minimum Skylight Area Total Proposed Skylight Area = Sum of the areas (rough H fTz Total Proposed Skylight Area opening) of each individual skylight. Step 4b — If complying with minimum effective aperture: ❑ Criterion 4b: Check if Proposed Skylight Effective Aperture is equal to or greater than Minimum Skylight Effective Aperture (J2 1). If this criterion checked, shall also fill out ENV -4-C (Page 3 of 3) Minimum Skylight Effective Aperture I 0?011 `, 'm Minimum Skylight Effective Aperture Proposed Skylight Effective Aperture. Shall be taken from ENV -4C (Page 3 of 3) Cell (AB) J Proposed Skylight Effective Aperture Step 4c Required ❑ Criterion 4c: Check if Proposed Skylight glazing or diffuser haze rating is equal or greater than 90% (K >_ 0.9). Skylight glazing or diffuser haze rating according to ASTM K Haze ratin g D1003 Haze rating is indicated on page of plans ❑ Complies with all of Criterion 4 if either Criterion 4a or Criterion 4b is checked, AND Criterion 4c is checked. Step 5 — If using PRIMARY SIDELIGHT to comply with the minimum skylight area requirements: ❑ Criterion 5: Check if Proposed Primary Sidelit Effective Aperture is greater than or equal to Minimum Sidelit Effective Aperture (M a L). Fill out remaining questions on Step 6 below. Minimum Sidelit Effective Aperture L01 '{ Minimum Sidelit Effective Aperture Enter Proposed Primary Sidelit Effective Aperture from M Proposed Primary Sidelit Effective Equation 146-A cell (Q) below 0.000 Aperture EQUATION 146-A: Effective Aperture for Primary Sidelit Area Rough opening of windows adjacent to the sidelit are in N o Total window area square feet Visible light transmittance of window O 0.000 Average VLT Primary sidelit daylight area determined according to P 0 Primary Sidelit Area §131(c)1 from cell (D), step 2 on ENV -4C (Page 1 of 3) Primary Sidelit Effective Aperture = (N X O) / (P) Enter results for Primary Sidelit Effective Aperture from Q 0.000 Primary Sidelit EA cell Q into cell M in Step 5 Step 6 ❑ Space PASSES: Check if Criterion 1 and 3 (page 1); and, Criterion 4 (page 2) are checked. ❑ Space PASSES: Check if Criterion 2 and 3 (page 1); and Criterion 5 (page 2) are checked. ❑ Space PASSES: Check only if Criterion 1 through 5 are all checked. Ener Pro 5.0 by Ener Soft User Number: 3151 RunCode: 2010-04-18T13:18:4 ID: 06-119.00 Pae 15 of 41 ENVELOPE MANDATORY MEASURES: NONRESIDENTIAL ENV -MM, Project Name Date LA QUINTA VILLAGE 4/18/2010 DESCRIPTION Building Envelope Measures: §118(x): Installed insulating material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20 Chapter 4, Article 3. §118(c): All Insulating Materials shall be installed in compliance with the flame spread rating, and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. §118(f): The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-13 between framing members. §117(x): All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. Manufactured fenestration products and exterior doors shall have air infiltration rates not exceeding 0.3 cfm/ft.z of §116(a) 1: window area, 0.3 cfm/ft.2 of door area for residential doors, 0.3 cfm/ft.2 of door area for nonresidential single doors (swinging and sliding),and 1.0 cfm/ft.2 for nonresidential double doors (swinging). §116(a) 2: Fenestration U -factor shall be rated in accordance with NFRC 100, or the applicable default U -factor. §116(a) 3: Fenestration SHGC shall be rated in accordance with NFRC 200, or NFRC 100 for site -built fenestration, or the applicable default SHGC. Site Constructed. Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be. §116(b):" weatherstripped (except for unframed glass doors and fire doors).' r 1 , r ' Ener Pro 5.0 by Ener Soft User Number: 3151 RunCode: 2010-04-18713:18:47 ID: 06-119.00 Pae 16 of 41 s OPCOMPLIANCE and, (Part" 1 of 5)' 'MECH 1C ,CERTIFICATE FIELD :INSPECTION ENERGY CHECKLIST = Pr' oject.Name :. LA QUINTA VILLAGE;:. Date 4/18/2010 `` Project Address Climate Zone Total Cond.' Floor Area Additiori Floor Area NWC Calle'Tampico:&'_Washirigton St" La Quinta 15: :.5,579 n/a' - -GENERAL INFORMATION'. Buildin T e'-' '. E Nonresidential D High, Rise Residential `❑ Hotel%Motel Guest•Room D .Schools(Public School) , ❑ Relocatable Public School Bldg 0 Conditioned Spaces p ?_ Unconditioned Spaces ,. affidavit Phase of. Construct ion:` : 0 . New. Construction '': ❑ Addition4 "` ❑ -Alteration'.'.'` ' Overall Envelope TDV Approach ofCompliance.:❑ Component 0 O:r. Unconditioned'(file affidavit).,, • Ener.. Front Orientation: N,. E; S',-.W or in Degrees: HVAC SYSTEM .DETAILS ` '' FIELD'INSPECTION ENERGY CHECKLIST_, -' „ .. Meets Criteria or Requirements E ui menu .. Ins ection Criteria,<. S ecial`Feature' Pass :' Fail3 Item,orSyste h7ags DH IN: Heater ❑ i.e.AC 1 „RTU 1, HP-11) ... E ui ment.T e°: a Electric Res DH Boller ' '� ; ;MOM Numberbf stems 1 - ❑ ® D Max Allowed Heating Ca aci : ,8;191 -Btu/hr y" ' . ❑ , .- . '. ® : _p , Minimum HeatingEfficient 0.98'EF p I 'Max Allowed CoolinCa acct n/a 13 ®a Coolie :Efficient n/a [3® M ®� f Duct Location/.R-Value .. n/a p®•..e�® ' Duct Leakage Testing If:Yes a t` ' ❑ ❑ MECH-4A must be submitted n/a Economizer's'_ . .. n/a_` ❑FROMp Thermostatn/a• ❑ Fan Control-' Ma111� '❑ WON FIELD:INSPECTION ENERGY•CHECKLIST E ui • riient2 Iris ection Criteria '' ,., S ecial Feature' Pass_Fail3 , Item or System Tags : ❑ ®" _ i:e. AC-1, RTU-1; HP-1 Bank ;Space�- Space #.1 " Equiment.T e° Packaged DX ❑d f] Number of Systems.: 4 ❑ ®° ®; { Max Allowed Heatin Ca' acct 79,222 Btu/hr ❑ 'v0" Ef z Minimum Heating ffficienc . n. "7.80:PISPF ❑ � 10 ' Max Allowed Conlin' Ca acct : 192,'742 Btu/hr `' - 13 ®' ,.. , Conlin Efficient 13.0 SEER / 1 "1.0 EER , :: ❑ ® 0 Duct Location/ R' Value R-8.0 ❑ 0 ®° Duct Leakage Testing - If Yes, a -; ; K MECH-4A :bust be submitted No Economizer. No Economizer ❑KIM Thermostat Se tliack'Required' ❑ ® _�® R Fan.Control CVolume : - ❑onstant E b®" ' ... t. Indicate special feature DETAILS on Page 2 of the Inspectior Checklist Form 2. If the Actual installed equipment performance efficiency"and capacity is less than the,Proposed {from the energy compliance submittal of from -- '. the building plans) the responsible party shall resubmif energy compliance to include the, new changes .3. For additional detailed' discrepancy use Page 2bf•the Inspection Checklist Form,'_ Indicate Equipment Type'. Gas'(Pkg�or, Split), VAV, HP (Pkg'or split)' Hydronic,,PTAC, or'other ,- Ener Pfo$.0b 'Ener Soft r UserWumber"3151;,; Run Code:'2010-04-18T13:18:47_ . ID:,06-119.00<: Page 28'of,4 CERTIFICATE' OF COMPLIANCE and . (Part 1 'of 5) MECH-1 Ci ° = '{ FIELD INSPECTION" ENERGY CHECKLIST. . Project Name Date -. ` LA WINTA VILLAGE - " ' .<' 4/18/2010`-,. . :. Rroject Address Climate Zone Total Cond. Floor Area; AdditiorrFloor Area < . NWC CalleTampico &Washington St . La Quinta 15 5,579 n/a GENERAL INFORMATION Buildin •T e: •. 0 Nonresidential,.' ❑ High-Rise Residential, 1i Hotel/Motel; Guest Room ❑ ",Schools (Public School) " D Relocatable Public, ® Conditioned Spaces z. p; Unconditioned Spaces , .. __ - .. ,_ a ffidavit " Phase of Construction:` . ' 0 _' New Construction O Addition. "'-' ❑ 'Alteration • ' •. J. Overall Envelo a TDV -Approach of Compliance:, ..• O Component © p O. Unconditioned,(file affidavit) Energy, Front Orientation: N,-E, S; W`oc' 6 Degrees:..]. HVAC SYSTEM DETAILS"./ FIEL'D-INSPECTION ENERGY CHECKLIST:' • Meets Criteria or.Re ' 'irements E ui menTz Ins `ection_Criteria Special Feature'• ' ,Pass_Fail Item or Tags �❑ i.e: AC-1, RTU-1',H Space #2 :E'ui ment T e° - Packaged.,QX. ❑' Number of Systems ' 2 ❑ `® ®� k . f MaxtAllowed Heatin 'Ca acit' 44;256 Btu/hr REM FEW Minimum Heating Efficienc 7.80 HSPF ❑ _ ® ®.. Y Mak Allowed Coolin 'Ca acit 121,089 Btu%hr '" ❑ pWINE Cooling Efficiency 13.0 SEER;711'.O EER ,: �'" p p Duci Location/ R-'Value- R-8:0 " " fb b Duct Leakage Testing - If Yes,,a ❑ MECH-4A must be:submitted NO Economizer; - No. Economizer' ❑' ® ® v Thermostat :Setback Required ❑ ., Fan Control s Constaht: O/Ume ❑; " 0W WON FIELD INSPECTION ENERGY. CHECKLIST ecial Feature' ". Pass Fail3 E ui inentz_ , Ins " ection.Criteria:',S Item or-System-Tags® 0 'Equipment Type'-. ❑ ® ❑ • Number of System's ❑ O ®A. Max Allowed Heatin Ca� aciiy W. ❑ 3'• ,. Minimum Heatin Efficienc '„ y 10 ® ❑ 4 Max Allowed Co ding Capacity ' ❑ O D" Coolin .Efficienc d ®".. .' Duct Location/ R-Value ❑® Duct L"eakage Testing -If Yes, a MECH-4A must-be submitted Economizer - .. ❑. :.. ! V O Thermostat', '❑ t - i• - -;v n Control - - :❑ ❑ "Mfa Indicate special feature DETAILS on Page 2 of the Inspection ChecklisYForm. If the Actual installed equipmentperformance efficiency and"capacity is less than the Proposed (from the energy compliance submittal or from the building plans) the responsible partyshall resubmit eriergy,compliance to include the new changes " 3.,For.additional detailed discrepancy use Page 2 of the `Inspection Checklist Form. 4. Indicate Equipment Type: Gas (Pkg or, Split), VAV, HP (Pkg or split), Flyd'ronic, PTA C, or other. Ener Pro 5.0 b Ener Soft User Number. 3151 RunCode: 2010-04-18T13:18:47 ID: 06-119.00 Page 29 of 41 • � t } CERTIFICATE OF COMPLIANCE and (Part 2 of 5) MECH-1 C FIELD INSPECTION ENERGY CHECKLIST rrojeCt Name Date LA QUINTA VILLAGE 1 411812010 SPECIAL FEATURES INSPECTION CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special iustification and documentation submitted. es: :18:47 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 3 of 5) MECH-1C Project Name Date LA QUINTA VILLAGE 411812010 Required Acceptance Tests Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the applicable boxes by all acceptance tests that apply and listed all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems. The NA number designates the Section in the Appendix of the Nonresidential Reference Appendices Manual that describes the test. Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Systems Acceptance: Before occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. Systems Acceptance: Before occupancy permit is granted. All newly installed HVAC equipment must be tested using the Acceptance Requirements. The MECH-1 C form is not considered a completed form and is not to be accepted by the building department unless the correct boxes are checked. The equipment requiring testing, person performing the test (Example: HVAC installer, TAB contractor, controls contractor, PE in charge of project) and what Acceptance test must be conducted. The following checked -off forms are required for ALL newly installed equipment. In addition a Certificate of Acceptance forms shall be submitted to the building department that certifies plans, specifications, installation, certificates, and operating and maintenance information meet the requirements of §10-103(b) and Title -24 Part 6. The building inspector must receive the properly filled out and signed forms before the building can receive final occupancy. TEST DESCRIPTION MECH-2A MECH-3A MECH-4A MECH-5A MECH-6A MECH-7A MECH-8A MECH-9A MECH-10A MECH-11A Hydronic Outdoor Constant Demand Supply System Automatic Ventilation Volume & Air Control Supply Valve Water Variable Demand For Single -Zone Distribution Economizer Ventilation Fan Leakage Temp. Flow Shed Equipment Re uirin Testing or Verification Oty. VAV & CAV Unitary Ducts Controls DCV VAV Test Reset Control Control Carrier 50HJQ005-3/516 6 0 0 ❑ ❑ ❑ ❑ 1 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ o ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Ener Pro 5.0 by Ener Soft User Number: 3151 Run Code: 20 10-04-1 8 713:18:47 ID: 06-119.00 Page 31 of 41 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 4 of_5) MECH-1C Project Name LA QUINTA VILLAGE = �.47 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 4 of_5) MECH-1C Project Name LA QUINTA VILLAGE = Date 4/18/2010 TEST DESCRIPTION MECH-12A MECH-13A MECH-14A MECH-15A r Equipment Re uirin Testing Fault Detection & Diagnostics Qty. for DX Units Automatic Fault Detection &- Diagnostics for Air & Zone Distributed Energy Storage DX AC Systems Thermal Energy Storage (TES) Systems Test Performed By: Carrier 50HJQ005-3/5/6 6 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑- ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑. ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ .❑ ❑ ❑ ❑ ❑. ❑ ❑ ❑ ❑ d ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ o ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑. Y ❑ ❑. ❑ ❑ ❑ ❑ ❑. ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ o ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑: ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ EnergyPro 5.0 by EnergySoft User Number 3151 RunCode: 2 0 1 0-04-18 713:18:47 ID: 06-119.00 Page 32 of 41 CERTIFICATE OF COMPLIANCE . - (Part.5 of 5) MECH-IC " Project Name Date LA QUINTA VILLAGE' 4/18/2010 a. .1 certify that this Certificate of Compliance documentation is accurate and com" late. Signature q� g (%1 C Name 1 , , :Wentien Huang P.E. Company Date 4116/2010 Address. 1837 Via "Del Rey EA # . /• _. ., CEPE #b 61 City/State/Zip South Pasadena. CA 91030 Phone (213)926-6236 The Principal Mechanical.besigner's Declaration Statement ' I am eligible under Division 3 of the Californja Business and Professions Code to accept responsibility for the mechanical . design. • This Certificate of Compliance identifies the mechanical features and performance specifications required for compliance with Title -24, Parts 1 and 6 of the California Code of Regulations. • The design features represented on this Certificate of Compliance are consistent with t information provided•to document this design, on the other applicable compliance forms. worksheets, calculations, plans d specific ons submitted the _to enforcement agency for approval with this building permit application. Name Wentien Huang" Signature Company Date Address • 1837 Via Del Rey License # •� j j fv ;City/State/Zip South Pasadena. CA 91030 Phone (323).256-6236' Mandatory Measures Indicate location on building plans of Note Block for Mandatory Measures MECHANICAL COMPLIANCE FORMS & WORKSHEETS check box if worksheet is included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the 2008 Nonresidential Manual. Note: The Enforcement Agency may require all forms to be incorporated onto the building plans. .10. MECH-1C Certificate of Compliance. Required on plans for all submittals. M MECH-2C Mechanical Equipment Summary is required for all. submittals. ® MECH-3C Mechanical Ventilation and Reheat is required for all submittals with mechanical ventilation. ® •MECH-4C ' Fan Power Consumption is required for all prescriptive submittals. { EnergPt 5.0 by EnergySott User Number: 3151 RunCode: 2010.04-18T13:18:4 ID: 06-119.00 Page 33 or 41 CERTIFICATE OF COMPLIANCE . - (Part.5 of 5) MECH-IC " Project Name Date LA QUINTA VILLAGE' 4/18/2010 Documentation Author's Declaration Statement .1 certify that this Certificate of Compliance documentation is accurate and com" late. Signature q� g (%1 C Name 1 , , :Wentien Huang P.E. Company Date 4116/2010 Address. 1837 Via "Del Rey EA # . /• _. ., CEPE #b 61 City/State/Zip South Pasadena. CA 91030 Phone (213)926-6236 The Principal Mechanical.besigner's Declaration Statement ' I am eligible under Division 3 of the Californja Business and Professions Code to accept responsibility for the mechanical . design. • This Certificate of Compliance identifies the mechanical features and performance specifications required for compliance with Title -24, Parts 1 and 6 of the California Code of Regulations. • The design features represented on this Certificate of Compliance are consistent with t information provided•to document this design, on the other applicable compliance forms. worksheets, calculations, plans d specific ons submitted the _to enforcement agency for approval with this building permit application. Name Wentien Huang" Signature Company Date Address • 1837 Via Del Rey License # •� j j fv ;City/State/Zip South Pasadena. CA 91030 Phone (323).256-6236' Mandatory Measures Indicate location on building plans of Note Block for Mandatory Measures MECHANICAL COMPLIANCE FORMS & WORKSHEETS check box if worksheet is included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the 2008 Nonresidential Manual. Note: The Enforcement Agency may require all forms to be incorporated onto the building plans. .10. MECH-1C Certificate of Compliance. Required on plans for all submittals. M MECH-2C Mechanical Equipment Summary is required for all. submittals. ® MECH-3C Mechanical Ventilation and Reheat is required for all submittals with mechanical ventilation. ® •MECH-4C ' Fan Power Consumption is required for all prescriptive submittals. { EnergPt 5.0 by EnergySott User Number: 3151 RunCode: 2010.04-18T13:18:4 ID: 06-119.00 Page 33 or 41 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2C Project Name Date LA'QUINTA VILLAGE 411812010 Indicate Air Systems Type Central, Single Zone, Packa e, VAV, or etc... Item or System Tags i.e. AC -1, RTU -1, HP -1 Bank Space -Space #1 Space #2 Number of Systems ", 4 2 Indicate Pacie Reference on Plans or Schedule and indicate the applicable exception(s) MANDATORY MEASURES T-24 Sections Heating Equipment Efficiency 112 a 7.80 HSPF 7.80 HSPF Cooling Equipment Efficiency 112(a) 13.0 SEER / 11.0 EER 13.0 SEER/ 11.0 EER HVAC Heat Pump Thermostat 112(b), 112 c Yes Yes Furnace Controls/Thermostat 112(c), 115(a) n/a n/a Natural Ventilation 121 b Yes Yes Mechanical Ventilation 121 b 0 cfm 255 cfm VAV Minimum Position Control 121 c No No Demand Control Ventilation' 121 c No Yes Time Control 122(e) Programmable Switch Programmable Switch Setback and Setup Control 122(e) Setback Required Setback Required Outdoor Damper Control 122(f) Auto Auto Isolation Zones 122 n/a n/a Pipe Insulation 123 Duct Insulation 124 R-8.0 R-8.0 PRESCRIPTIVE MEASURES Calculated Design Heating Load 144(a & b 79,222 Btu/hr 44,256 Btu/hr Proposed Heating Capacity 144(a & b 116,171 Bturhr 58,085 Btu/hr Calculated Design Cooling Load 144(a & b 134,920 Btu/hr 84,762 Btu/hr Proposed Cooling Capacity 144(a & b 140,898 Btu/hr 65,535 Btu/hr Fan Control 144(c) Constant Volume Constant Volume DP Sensor Location 144(c) Supply Pressure Reset (DDC only) 144(c) Yes Yes Simultaneous Heat/Cool 144(d) No No Economizer 144 a No Economizer No Economizer Heat and Cool Air Supply Reset 144(f) Constant Temp Constant Temp Electric Resistance Heating' 144 Constant Temp Constant Temp Air Cooled Chiller Limitation 144(i) Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(k) No No 1. Total installed capacity (MBtu/hr) of all electric heat on this project exclusive of electric auxiliary heat for heat pumps. If electric heat is used explain which exception(s) to §144(g) apply. Energ Pro 5.0 by Energ Soft User Number. 3151 Run Code: 2010-04-18T13:18:4 ID: 06-119.00 Page 34 of 41 WATER SIDE SYSTEM REQUIREMENTS Part 2 of 2 MECH-2C Project Name Date LA QUINTA VILLAGE 4/18/2010 WATER SIDE SYSTEMS: Chillers, Towers, Boilers, H dronic Loops Item or System Tags (i.e. AC -1, RTU -1, HP-1)' Number of Systems Indicate Page Reference on Plans or S ecification2 MANDATORY MEASURES. T-24 Sections Equipment Efficiency 112(a) Pipe Insulation 123 PRESCRIPTIVE MEASURES Cooling Tower Fan Controls 144(a & b - Cooling Tower Flow Controls 144(h) Variable Flow System Design 144(h) Chiller and•Boiler Isolation 144 CHW and HHW Reset Controls 144 WLHP Isolation Valves 144 • VSD on CHW, CW & WLHP Pumps>5HP 144 DP Sensor Location 144 Heat Rejection System 144(h) 1. The proposed equipment need to match the building plans schedule or specifications. If a requirement is not applicable, put "WA" in the column nest to applicable section. 2. For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column next to applicable section. Service Hot Water Pool Heating Item or System Tags Heater (i.e. WH -1, WHP, DHW, etc...)' x�,,._„- , ,. ,..,, Number of Systems Indicate Page Reference on Plans or Schedule2 MANDATORY MEASURES I T-24 Sections SERVICE HOT WATER Certified Water Heater 111, 113 a Hot Aqua 24-120 Water Heater Efficiency 113(b) 0.98 EF Service Water Heating Installation 113(c) Pipe Insulation 123 rVa POOL AND SPA Pool and Spa Efficiency and Control 114(a) n/a Pool and Spa Installation 114 b n/a Pool Heater — No Pilot Light 115(c) n/a Spa Heater — No Pilot Light 115 d Pipe Insulation 123 1. The Proposed equipment needs to match the building plans schedule or specifications. If a requirement is not applicable, put "N/A” in the column next to applicable section. 2. For each water heater, pool heater and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. Ener Pro 5.0 by EnerqySoft User Number. 3151 RunCode: 2010-04-18T13:18:4 ID: 06-119.00 Page 35 of 41 MECHANICAL VENTILATION AND REHEAT MECH-3C Project Name LA QUINTA VILLAGE Date 4/18/2010 MECHANICAL VENTILATION 121 b 2 REHEAT LIMITATION (§144(d)) - AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H I J K L M N Zone/System Condition Area ft2 CFM per ft2 Min CFM Number By Area Of B X C People CFM per Person Min CFM REQ'D by V.A. Occupant Max of E X F D or G Design 50% of Ventilation Design Zone Air Supply CFM CFM B X 0.4 CFM / ft2 Max. of Columns H, J, K, 300 CFM Design Minimum Air Transfer Setpoint Air Bank Space 4,401 0.15 660 660 0 660 Bank Space - Space #1 Total 660 0 Retail 1,178 0.25 295 295 255 40 Space #2 Total 295 255 Totals Column I Total Design Ventilation Air C Minimum ventilation rate per Section 121, Table 121-A. E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load foregress purposes fors aces without fixed setting. H Re uired Ventilation Air REQ'D V.A. is the larger of the ventilation rates calculated on an AREA BASIS or OCCUPANCY BASIS Column D or G). I Must be greater than orequal to H, or use Transfer Air column N to make up the difference. J Design tan supply CFM Fan CFM x 50%• or the design zone outdoor airflow rate per 121. K Condition area ft2 x 0.4 CFM / ft2; or L Maximum of Columns H, J, K, or 300 CFM . M This must be less than orequal to Column L and greater than orequal to the sum of Columns H plus N. N Transfer Air must be provided where the Required Ventilation Air (Column H) is greater than the Design Minimum Air (Column M). Where required, transfer air must be greater than or . equal to the difference between the Required Ventilation Air Column H and the Design Minimum Air Column M), Column H minus M. Ener Pro 5.0 by EnergySoft User Number. 3151 RunCode: 2010-04-18713:18:47 ID: 06-119.00 Page 36 of 41 FAN'POWER CONSUMPTION MECH-4C .Project Name LA QUINTA VILLAGE Date 4/18/2010 NOTE: Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using the Prescriptive Approach. See Power Consum tion'of fan §144(c). A B C D E F Fan Description Design Brake HP' Efficienc Number of Fans Peak Watts B X E X 746 / C X D - Motor Drive Supply Fan 0.700 76.0% 97.0% 4.0 2,833 TOTALS AND ADJUSTMENTS , FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 1 TOTAL FAN SYSTEM POWER WATTS, SUM COLUM F 2,833 2 SUPPLY DESIGN AIRFLOW CFM 6,400 A) If filer pressure drop (SP.) is greater than 1 inch W. C. or 245 Pascal then enter SP, on line 4: Enter Total Fan pressure drop across the fan (SPf) on Line 5. 3 TOTAL FAN SYSTEM POWER INDEX Row 1 / Row 2 W/CFM 4 . SPa 5 SPf B Calculate Fan Adjustment and enter on line 6. 6 Fan Adjustment = 1- SPa'— 1 / SPf C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Line 3 x Line'6)' 0.443 W/CFM 1. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/CFM for Constant Volume systems or 1.25 W/CFM for VAV systems. r Ener Pro 5.0 by EnergySoft User Number. 3151 RunCode: 2010-04-18T13:18:4 ID: 06-119.00 Page 37 of 41 FAN POWER CONSUMPTION MECH-4C Project Name LA QUINTA VILLAGE Date 4/18/2010 NOTE: Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using the Prescriptive Approach. See Power Consumption of fan §144(c). . A -B. C. _ D. E IF _ Fan Description Design Brake HIP Efficienc Number of Fans Peak Watts B X E X 746 / C X D Motor Drive Supply Fan 0.700 76.0 V. 97.0% 2.0 1,417 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 1 TOTAL FAN SYSTEM POWER WATTS, SUM COLUM F v 1;417 2 SUPPLY DESIGN AIRFLOW CFM 3,200 A) If filer pressure drop (SP.) is greater than 1 inch W. C. or 245 Pascal then enter SP, on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 3 TOTAL FAN SYSTEM POWER INDEX Row 1 /Row 2 W/CFM 4 SPa 5 SP, B Calculate Fan Adjustment and enter on line 6.' 6 Fan Adjustment =1- SPa-1 / SP, C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6)' 0.443 W/CFM 1. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/CFM for Constant Volume systems or 1.25 W/CFM for VAV systems. Ener Pro 5. t—y Ener Soft' User Number: 3151 RunCode: 2010-04-18T13:18:4 ID: 06-119.00 Page 38 of 41 MECHANICAL MANDATORY MEASURES: NONRESIDENTIAL MECH-MM Project Name Date LA QUINTA VILLAGE 4/18/2010 Equipment and System Efficiencies §111: Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. §115(a): Fan type central furnaces shall not have a pilot light. §123: Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. §124: Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of the CMC Standards. Controls §122(e): Each space conditioning system shall be installed with one of the following: 1 A. Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or 1 B. An occupancy sensor to control the operating period of the system; or 1 C. A 4 -hour timer that can be manually operated to control the operating period of the system. 2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 §122(g). square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. §122(c): Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. §122(b): Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the §122(a&b): control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. Ventilation §121(e): Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. §122(f): All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. Ventilation System Acceptance. Before an occupancy permit is granted for a newly constructed building or space, or a §121(f): new ventilating system serving a building or space is operated for normal use, all ventilation systems serving the building ors ace shall be certified as meeting the Acceptance Requirements for Code Compliance Service Water Heating Systems §113(c) Installation 3. Temperature controls for public lavatories. The controls shall limit the outlet Temperature to 110 ° F. 2 Circulating service water -heating systems shall have a control capable of automatically turning off the circulating pump when hot water is not required. Ener Pro 5.0 by Ener Soft User Number: 3151 RunCode: 2010-04-18713:18:47 ID: 06-119.00 Page 39 of 41 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name LA QUINTA VILLAGE Date 4/18/2010 System NameFloor Bank Space - Space #1 Area 4,401 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 4 COIL CFM Total Room Loads 5,147 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 46,500 92,576 11,196 1,986 59,155 Total Output Btuh 186,000 0 Output Btuh/s ft 42.3 4,629 2,958 Cooling System 0 0 Output perSystem 46,300 0 0 0 0 Total Output Btuh 185,200 9,670 11,196 -9,670 Total Output Tons 15.4 4,629 2,958 Total Output Btuh/s ft 42.1 Total Output s ft/ron 285.2 1 111,504 1 55,400 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 6,400 Carrier 50HJQ005-3/5/6 140,898 27,295 116,171 Airflow (cfm/sift 1.45 Airflow cfm/Ton 414.7 Outside Air % 0.0% Total Adjusted System Output 140,898 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 27,295 116,171 Jul 5 -PM 7 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 70 OF 70 OF 97 OF 98 OF Heating Coil Supply Fan o 6,400 cfm 98 F ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 109/77°F Outside Air 0 cfm 79 / 65 OF 79/65°F 59/58°F 60/58°F ........... _QWt°' - Cooling Coil Supply Fan 61 / 59 OF 6,400 cfm - -- 50.2% ' ROOM 78 / 65 OF - A� EnergyPro 5.0 by EnergySoft User Number: 3151 RunCode: 2010-04-18713:18:47 ID: 06-119.00 Page 40 of 41 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name LA QUINTA VILLAGE Date 4/18/2010 System Name Space #2 Floor Area 1,178 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 3,665 Return Vented Lighting Return Air Ducts Return Fan Ventilation 255 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. Sensible Latent CFM 50,095 9,061 727 0 2,505 0 10,112 21729 255 4,835 2,505 1 70,051 11,790 PEAK Heating System Sensible Output perSystem, 46,500 21,755 Total Output Btuh 93,000 Output Btuh/s ft 78.9 1,088 Cooling System 0 Output perSystem 46,300 11,853 Total Output Btuh 92,600 -4,835 Total Output ons 7.7 1,088 Total Output Btuh/s ft 78.6 Total Output s ft/Ton 152.7 30,948 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 3,200 Carrier 50HJQ005-3/5/6 65,535 17,685 58,085 Airflow cfm/s ft 2.72 Airflow cfm/Ton 414.7 Outside Air % 8.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 65,535 .17,685 58,085 Jul 2 PM I Jan 1 AM Outside Air cfm/s ft 0 22 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 0-0 Outside Air 255 cfm 70 OF 66 OF 97 OF 98 OF n Heating Coil Supply Fan 3,200 cfm 98 OF ^ ROOM' 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 255 cfm 75 ! 64 OF 78/66°F 59/58°F 60/59°F Cooling Coil Supply Fan 3,200 cfm 61 / 59 OF ..._..._.._.„-........... ........— 59.2% ROOM 74164 OF EnergyPro 5.0 by EnergySoff User Number: 3151 RunCode: 2010-04-18713:18:47 /D: 06-119.00 Page 41 of 41 CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG -1C PROJECT NAME RETAIL SHOPS — LA QUINTA VILLAGE DATE 06-03-10 PROJECTADDRESS 50-991 Washington Street Climate Zone: Building CFA: 1134SF Unconditioned Floor Area: Lo Quinta, California 92253 140SF GENERAL INFORMATION Building Type: Ca Nonresidential ❑ High -Rise Residential ❑ Hotel/Motel ❑ Schools ❑ Relocatable Public Q Conditioned Spaces Q Unconditioned Spaces Schools Phase of Construction: ❑ New Construction ❑ Addition ❑ Alteration Method of Compliance: ❑ Complete Building Q Area Category ❑ S WE /0 Documentation Author's Declaration Statement ��. ®}►.• ' I certify that this Certificate of Compliance documentation is accurate and complete. � Name LINO PALMIERI Si re EE 8968 (V0, 4 X965 Company PALMIERI & ASSOCIATES, INC. Date: —10° Address 232 N. LAKE AVENUE SUITE #2100F CA1.1� City/State/Zip PASADENA, CA. 91101 Phone: (626) 440-1313 Principal Lighting Designer's Declaration Statement • I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the lighting design. • This Certificate of Compliance Identifies the lighting features and performance specifications required for compliance with Title 24, Pages 1 and 6 of the California Code of Regulations. • The design features represented on this Certificate of Compliance are consistent with the i rpa ROES cu QROF /0 this design on the other applicable compliance forms, worksheets, calculations, plans an ficglj enforcement agency for this approval with building permit application. Name LINO PALMIERI Will rtia re' E 8965 Company PALMIERI & ASSOCIATES, INC. Phone: 4401313 Address232 N. LAKE AVENUE SUITE #210 J'�,9 Uce ICCTR� tr , City/State0p PASADENA, CA. 91101C CAL 06-0 Lighting Mandatory Measures Indicate location on building plans of Mandatory Measures Note Block: LIGHTING COMPLIANCE FORMS & WORKSHEETS (check box if worksheet is included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. ❑ LTG -1 -C Pages 1 through 4 Certificate of Compliance. All pages required.on ❑ LTG -2-C Lighting Controls Credit Worksheet ul I ISAFETo( p ® LTG -3-C Indoor Lighting Power Allowance m/ i I ❑ LTG -4-C Pages 1 through 4 Tailored Method Worksheet;I _..r, r-r1NSTRUCTIU'4 11 1 ❑ LTG -5-C Pages 1 and 2 2008 "Nonresidential Compliance Forms Line Voltage Track Lighting Worksheet DATE-. AUGUST 2009 CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG -1 C INDOOR LIGHTING SCHEDULE & FIELD INSPECTION ENERGY CHECKLIST FRaecT NAME RETAIL SHOPS — LA QUINTA VILLAGE DATE 06-03-10 INSTALLATION CERTIFICATE, LTG-1-INST (Retain a copy & verify form is completed & signed). Field Inspection ❑ CERTIFICATE OF ACCEPTANCE, LTG -2A (Retain a copy & verify form is completed &signed). Field inspection ❑ A separate Lighting Schedule Must Be Filled Out for Conditioned & Unconditioned Spaces Installed Lighting Power listed on this Lighting Schedule is only for: Q CONDITIONED SPACES ❑ UNCONDITIONED SPACES ❑ The actual Indoor lighting power listed below Includes all Installed permanent & portable lighting systems in accordance with (SS)146(a) ❑ Only for offices: Up to the first 0.2 watts per square foot of portable lighting shall not be required to be Included in the calculation of actual Indoor lighting power density in accordance with the Exception to (SS)146(a). All portable lighting in excess of 0.2 watts per square foot is totaled below. Luminaire Schedule (Type, Lamps, Ballasts) Installed Watts A B C D E F G H Name Or Item Tag Complete Luminaire Description (Le.: 3 Lamp fluorescent troffer, F32T8, one dimmable electronic ballast) A • a co U ° R C � How wattage was determined; O` y 'R C 3 Z - ami LL N x 5 0 Field Inspector = U b E c° LLJ 4- 2< U " Z �M v 7 ti•' UIQ d O N `o Q �' 0 a. U. 1 /6; 2'x4' FIXT. 4L—F32T8 ELECTRONICAL ❑ 114 ® ❑ 14 1596 ❑ ❑ 15 4' WRAPAROUND 2L—F32T8 ELECTRONICAL ❑ 64 ® ❑ 1 64 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ O ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ E]❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ INSTALLED WATTS PAGE TOTAL: 1660 Building total number of pages 1 Installed Watts Building Total 1660 (Sum of all pages) Enter into LTG -1C Page 4 of 4 1. Wattage shall be determined according to Section 130(d & e). Wattage shall be rating of light fixture, not rating of bulb. 2. if Fail then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. 2008 Nonresidential Compliance Forms AUGUST 2009 C) N ;+ �. � ❑ ❑ � D n Z � z n 0 2N m CO ! oo.. a g � a d -•+ M M. co o cm T y O m o: r � O m Vl � C M P J R. (nD .�. N 0 Cr N W T N^ O � N� Oy 0 CL. -w 7 0 Z YJ A �i CD 0 ° M c�i D m 3 0 CL v A) CD � r r " �v m � m m CD °• 3 •a W a m� Z 3 '•� D CO) N � f o g c e w Cr � c � � n m = 0 N CL Q - IV W y �� O N N _ M W Z„ m � 171 CD � m N ID ^' -0. rn CD � O eD O o fT1 O r N m fn a � r Ch ° y C � n� d n� O D p c N Z � r- 171 m 0 � so � M °. n D N � : ?CD w o m c y a.a � m C/) 0 Z d O W m m M C:) Z1 pr ID Ch w G r - N �• C d a � y � � r M .y, CO CD CL C 13 fY 0 � Z N ° � a Z go `•C •p fJ V: n1 CL d ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ n �� a o� m Features 0 CD 0 � °z 'j. S �_ v � ai -0. Watts per s d a O V d -+ � Luminaire � = � z o m @ � m CEC c Cn cn �► Z � o ❑❑o❑❑❑.❑❑❑❑❑❑❑❑❑®® Default d_ � D w c �D from Q,f � ;=0 � a,M v � � ty d � NA -8 o M H F g 3; c Ems, g p 1� According g �U s m o� � o c � D❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ .90 to SS 130 'm `D a 0.0 c a n IV :I. c d a _rn_ a � � a � a r y A� 111 O (d or ) �. � t7 � m 'o ca � � � cc m so c -� Number of � a a � � � Luminaires � c o � 0 Installed Watts � a ° � m o c � (D x F) � m d m m D m c c r 0 a w .. CD H n � ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ Pass �� �• ' � � � � O MA 7 N T S O O O y � CO M CD O �0 A•I CL 9p- A � ❑ ❑ O � d 0 ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ I ll Fail C� � 'o' a� -- 0 CO CERTIFICATE OF COMPLIANCE (Part 3 of 4) LTG -1 C PROJECTNAME RETAIL SHOPS — LA QUINTA VILLAGE DATE 06-03-10 INDOOR LIGHTING SCHEDULE & FIELD INSPECTION ENERGY CHECKLIST Fill in controls for all spaces: a) area controls, b) multi-level controls, c) manual daylighting controls for daylit area&& > 250ft , automatic daylighting controls for daylit areas > 2,560ft , d) shut-off controls, e) display lighting controls, f) tailored lighting controls - general lighting controlled separately from display, ornamental and display case lighting and g) demand responsive automatic controls for retail stores > 50,000ft , in accordance with Section 131. MANDATORY LIGHTING CONTROLS - FIELD INSPECTION ENERGY CHECKLIST Field Inspector Number Special Type/Description of Units Location in Building Features Pass Fail CONTACTOR 3 PANEL 'A3' ❑ ❑ ❑ TIMECLOCK 1 PANEL °A3' ❑ ❑ ❑ REMOTE TITLE "24° BY—PASS 1 SALES AREA ❑ ❑ ❑ DUAL 2 SALES ❑ ❑ O SINGLE 1 TOILET ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ SPECIAL FEATURES INSPECTION CHECKLIST (see Page 2 of 4 of LTG -1C) The local enforcement agency should pay special attention to the Items specified In this checklist. These Items require special written justification and documentation, and special verification. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Filed Inspector Notes or Discrepancies: 2008 Nonresidential Compliance Forms AUGUST 2009 CERTIFICATE OF COMPLIANCE (Part 4 of 4) LTG -1C PROJECT NAME RETAIL SHOPS — LA QUINTA VILLAGE DATE 06-03-10 Conditioned and Unconditioned space Lighting must not be combined for compliance Indoor Lighting Power for Conditioned Spaces Indoor Lighting Power for Unconditioned Spaces Installed Lighting watts Installed Lighting Watts (from Conditioned LTG -1C Page 2) 1660 (from Unconditioned LTG -1C Page 2) 96 Lighting Control Credit _ Lighting Control Credit _ Conditioned Spaces (from LTG -2C) Unconditioned Spaces (from LTG -2C) Adjusted Installed = 1660 Adjusted Installed ._ 96 Lighting Power Lighting Power Complies if Installed:S Allowed $ Complies if Installed < Allowed Allowed Lighting Power 1870 Allowed Lighting Power 98 Conditioned Spaces (from LTG -3C) Unconditioned Spaces (from LTG -3C) Required Acceptance Tests Designer: This form is to be used by the designer and attached to the plans. Listed below is the acceptance test for the Lighting system, LTG -2A. The designer Is required to check the acceptance tests and list all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. If all the lighting system or control of a certain type requires a test, list the different lighting and the number of systems. The NAT Section in the Appendix of the Nonresidential Reference Appendices Manual describes the test. Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Forms can be grouped by type of Luminaire controlled. Enforcement Agency: Systems Acceptance. Before Occupancy Permit is granted for a newly constructed building or space or when ever new lighting system with controls Is installed in the building or space shall be certified as meeting the Acceptance Requirements. The LTG -2A form Is not considered a complete form and is not to be accepted by the enforcement agency unless the boxes are checked and/or filled and signed. In addition, a Certificate of Acceptance forms shall be submitted to the enforcement agency that certifies plans, specifications, Installation certificates, and operating and maintenance information meet the requirements of (SS)10-103(b) of Title 24 Part 6. The field Inspector must receive the properly filled out and signed fortes before the building can receive final occupancy. A copy of the LTG -2A for each different lighting luminaire control(s) must be provided to the owner of the building for their records. Luminaires Controlled LTG -2A X b Controls & Sensors & E n c Automatic Daylighting Equipment Requiring Testing Description Z c v Location Controls Acceptance T CONTACTOR (3P) 1 PANEL 'A3 O TC TIMECLOCK 1 O v REMOTE TITLE '24' BY-PASS TIMER 1 SALES O S SINGLE 1 TOILET O SS DUAL 2 SALES O D D O O 20081 Nonresidential Compliance Forms AUGUST 2009 INDOOR LIGHTING POWER ALLOWANCE LTG -3C PROJECT NAME RETAIL SHOPS — LA QUINTA VILLAGE °ATE 06-03-10 ALLOWED LIGHTING POWER (Choose One Method) A Separate LTG -3C Worksheet Must Be Filled Out for Conditioned & Unconditioned Spaces. Indoor Lighting Power Allowances listed on this page are only for: C]CONDITIONED SPACES QUNCONDITIONED SPACES COMPLETE BUILDING METHOD BUILDING CATEGORY (From (SS) 146 Table 146-E) WATTS PER (ft2) COMPLETE BLDG. AREA ALLOWED WATTS BUILDING CATEGORY (From (SS) 146 Table 146-F) WATTS PER (ft2) AREA (ft2) ALLOWED WATTS ELECTRICAL ROOM 0.7 140 98 Wattage Allowance (B X C) Description(s) and Quantity of Special Luminalre Types In each Primary Function Area Total Design Watts ALLOWED WATTS Smaller of D or F AREA CATEGORY METHOD - Part A A B C D BUILDING CATEGORY (From (SS) 146 Table 146-F) WATTS PER (ft2) AREA (ft2) ALLOWED WATTS ELECTRICAL ROOM 0.7 140 98 Wattage Allowance (B X C) Description(s) and Quantity of Special Luminalre Types In each Primary Function Area Total Design Watts ALLOWED WATTS Smaller of D or F :d Sum of Additional Allowed Watts from Area Category Method - Part B (from table below) TOTALS 140 1 98 AREA WATTS AREA CATEGORY METHOD - Part B Additional Wattage Allowance (from Table 146-F Footnotes) A B C D E F G Primary Function Sq Ft Additional Watts Per ft Allowed Wattage Allowance (B X C) Description(s) and Quantity of Special Luminalre Types In each Primary Function Area Total Design Watts ALLOWED WATTS Smaller of D or F :d TOTALS - Enter Into Area Category Method - Part A (table above) 1. Additional watts available only when allowed according to the footnotes on bottom of Table 146-F for chandelier or sconce; art, craft, assembly or manufacturing specialized task work; precision commercialfindustrial work; or lab specialized task work. - 2. Special luminaires are light fixtures described In the Table 146-F Footnotes that are subject to an additional wattage allowance. TAILORED METHOD Total Allowed Watts using the Tailored Method taken from LTG -4C (Page 1 of 4) Row 3 The Indoor lighting power allowance using the Tailored Method of compliance shall be determined using the LTG -4C set of forms. A separate set of LTG -4C forms shall be filled out for CONDITIONED and UNCONDITIONED spaces. 2008 Nonresidential Compliance Forms August 2009 INDOOR LIGHTING POWER ALLOWANCE LTG -3C PROJECT NAME RETAIL SHOPS — LA QUINTA VILLAGE DATE 06-03-10 ALLOWED LIGHTING POWER (Choose One Method) arate LTG -3C Worksheet Must Be Filled Out for Conditioned & Unconditioned Spaces. Indoor Lighting Power Allowances rristed on this page are only for: Q CONDITIONED SPACES . ❑ UNCONDITIONED SPACES COMPLETE BUILDING METHOD BUILDING CATEGORY (From (SS) 146 Table 146-E) WATTS PER (ft') COMPLETE BLDG. AREA ALLOWED WATTS BUILDING CATEGORY (From (SS) 146 Table 146-F) WATTS PER (ft') AREA (ft') ALLOWED WATTS SALES 1.7 1081 1838 TOILET 0.6 53 32 AREA CATEGORY METHOD - Part A A B C D BUILDING CATEGORY (From (SS) 146 Table 146-F) WATTS PER (ft') AREA (ft') ALLOWED WATTS SALES 1.7 1081 1838 TOILET 0.6 53 32 d Sum of Additional Allowed Watts from Area Category Method - Part B (from table below) TOTALS 1134 1870 AREA WATTS AREA CATEGORY METHOD - Part B Additional Wattage Allowance (from Table 146-F Footnotes) A B C D E F Total Design Watts G Primary Function Sq Ft Additional Watts Per ft Allowed Wattage Allowance (B X C) Description(s) and Quantity of Special Luminalre Types in each Primary Function Area ALLOWED WATTS Smaller of D or F TOTALS - Enter Into Area Category Method - Part A (table above) 1. Additional watts available only when allowed according to the footnotes on bottom of Table 146-F for chandelier or sconce; art, craft, assembly or manufacturing specialized task work; precision commercial/industrial work; or lab specialized task work. 2. Special luminaires are light fixtures described in the Table 146-F Footnotes that are subject to an additional wattage allowance. TAILORED METHOD Total Allowed Watts using the Tailored Method taken from LTG -4C (Page 1 of 4) Row 3 The Indoor lighting power allowance using the Tailored Method of compliance shall be determined using the LTG -4C set of forms. A separate set of LTG -4C forms shall be filled out for CONDITIONED and UNCONDITIONED spaces. 2008 Nonresidential Compliance Forms August 2009 CERTIFICATE OF COMPLIANCE (Part 1 of 4) OLTG-1-C PROJECT NAME RETAIL SHOPS — LA QUINTA VILLAGE DATE 06-03-10 PROJECT ADDRESS 50-991 Washington Street Total Hardscape Illuminated Area: La Quinta, California 92253 12460SF GENERAL INFORMATION Phase of Construction: Q New Construction ❑ Addition AI �ROFES Documentation Author's Declaration Statement * I certify that this Certificate of Compliance documentation is accurate and complete. Name LINO PALMIERI ure , E 8965rn Company PALMIERI & ASSOCIATES, INC. Date: 6-03-10 s C Address i` RIp� 232 N. LAKE AVENUE SUITE #210 9 City/State/Zip PASADENA, CA. 91101 Phone: (626) 440-1313 Principal Lighting Designer's Declaration Statement • I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the lighting design. • This Certificate of Compliance identifies the lighting features and performance specifications required for compliance with Title 24, Pages 1 and 6 of the California Code of Regulations. 0 QRQFES • The design features represented on this Certificate of Compliance are consistent with the ' on p i ument this design on the other applicable compliance forms, worksheets, calculations, plans a cc�ti i he enforcement agency for approval with this building permit application. Name LINO PALMIERI ure E 8965 Company PALMIERI &ASSOCIATES, INC. Pho 26) 440-1313 . Address 232 N. LAKE AVENUE SUITE #210 `P�q C R n 8965 City/State/Zip PASADENA, CA. 91101 06-03-10 Principal Lighting Designer's Declaration ® I certify this Certificate of Compliance documentation is accurate and complete, and accounts for all outdoor lighting power, including building mounted, pole mounted, as well as all other outdoor lighting designed for this site, and that Additional Lighting Power Allowances for Specific Applications or Additional Lighting Power Allowances for Ordinance Requirements have not been counted more than one time for the same area, in accordance with Section 147 of the Standards. r Outdoor Lighting Mandatory Measures Indicate location on building plans of Mandatory Measures Note Block - LIGHTING COMPLIANCE FORMS.& WORKSHEETS (check box if worksheet is included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. 0 OLTG-1-C Certificate of Compliance. All 4 pages required on plans for all submittals. ❑ OLTG-2-C (Page 1. of 3) Lighting Wattage Allowances for General Hardscape, Sales Frontage, or Ornamental Lighting . Optional on plans. ❑ OLTG-2-C (Page 2 of 3) Lighting Wattage Allowances Per Application or Per Area. Optional on plans. ` 0 OLTG-2-C (Page 3 of 3) Additional Lighting Power Allowance for Ordinance Requirements. Optional on plans. 2008 Nonresidential Compliance Forms AUGUST 2009 CERTIFICATE OF COMPLIANCE (Part 2 of 4) OLTG-1-C COMPLIANCE FIXTURE/LIGHTING CONTROL SCHEDULE & FIELD INSPECTION CHECKLIST PROJECT NAME RETAIL SHOPS - LA QUINTA VILLAGE DATE 06-03-10 INSTALLATION CERTIFICATE, OLTG-1-INST (Retain a copy & verify form is completed & signed) Field Inspection ❑ CERTIFICATE OF ACCEPTANCE, OLTG-2A (Retain a copy & verify form is completed & signed). Field inspection ❑ Luminaire Schedule Installed Watts A B C D E F G H I Name Or Item Tag Luminaire Description See footnote below (i.e.: 1 Lamp pole -top shoe -box 400 watt metal halide c M 7 4) (J L CL m E 7 J L G�1f�''C °- G1 (n LL How wattage was determined ° L E 7 3 Z J �' +°X N E 0 Field Inspector 4°E0o d O Q D w Z O' o. 0 O 8 Q r- N ca 'gyp d LL WALL PACK 10OMH ELECTRONIC 110 ❑ ❑ ❑ 4 440 1 ❑ D WALL PACK 10OMH ELECTRONIC 110 ❑ ❑ ❑ 3 330 ❑ ❑ WALL PACK 10OMH ELECTRONIC 110 ❑ ❑ ❑ 3 330 ❑ ❑ WALL PACK 10OMH ELECTRONIC 110 ❑ ❑ ❑ 3 330 ❑ ❑ ❑ ❑ ❑ ❑ O ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Enter Total into OLTG-1 C; Page 4 of 4; Row H; Total Installed Watts: 1430. 1. Type of luminaire (i.e.: post top, wall pack, surface, shoe box); for non -incandescent luminaires, indicate nominal lamp wattage and lamp type (Le.: fluorescent, incandescent, HID); ballast type (i.e.: electronic or magnetic); number of lamps and number of ballasts per luminaire. For incandescent luminaires, the luminaire wattage listed in column D shall be maximum relamping rated wattage on a permanent factory -installed label on the luminaire, NOT the wattage of the lamp (bulb) used, in accordance with Section 130 (d or e). 2. If fail then describe on Page 2 of the Inspection Checklist Form & take appropriate action to correct Verify building plans if necessary. EXEMPT LUMINAIRES I Field Inspection ❑ Name or Symbol Description of exempt luminaires in accordance with (SS)147 MANDATORY CONTROLS Field Inspection ❑ # Description Location # Description Location SPECIAL FEATURES INSPECTION CHECKLIST (see Page 2 o 4 of OLTG-1C) The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Filed Inspector Notes or Discrepancies: 2008 Nonresidential Compliance Forms AUGUST 2009 CERTIFICATE OF COMPLIANCE (Part 3 of 4) OLTG-1-C PROJECT NAME RETAIL SHOPS - LA QUINTA VILLAGE DATE 06-03-1 b A. OUTDOOR LIGHTING ZONE: ❑ OLZ1 ❑ OLZ2 ® OLZ3 ❑ OLZ4 Is the Outdoor Lighting Zone:® Default in accordance with (SS) 10-114, or ❑ Amended by JHA Complete the information below if the default Outdoor Lighting Zone has been amended by the local jurisdiction having authority (JHA): ❑ The site is a government designated park, recreation area, wildlife preserve, or portion thereof, and has been designated as LZ2 or LZ3, in accordance with Table 10-114-A, because the site is contained within such a zone. ❑ The local jurisdiction having authority has officially adopted a change to the State Default Lighting Zone and has notified the Energy Commission by providing the materials required in (SS) 10-114(d) to the Executive Director. ❑ The adopted change is posted on the Energy Commission website. B. ADDITIONAL LIGHTING POWER ALLOWANCE FOR ORDINANCE REQUIREMENTS Are additional lighting power allowances for ordinance in Table 147-C used? ❑ Yes ® No Complete the information below if additional lighting power allowances for ordinance requirements are used: ❑ The local jurisdiction having authority has officially adopted specific outdoor light levels, which are expressed as average or minimum footcandle levels, by following a public process that allowed for formal public notification, review, and comment about the proposed change. ❑ The local jurisdiction having authority which adopted specific outdoor light levels and has notified the Commission by providing the following materials required (SS) 10-114(f) to the Executive Director. C. ACCEPTANCE FORMS Required Acceptance Tests Designer: This form is to be used by the designer and attached to the plans. Listed below is the acceptance test for the Lighting system, LTG -2A. The designer ' is required to check the acceptance tests and list all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. If all the lighting system or control of a certain type requires a test, list the different lighting and the number of systems. The NA7 Section in the Appendix of the Nonresidential Reference Appendices Manual describes the test. Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Forms can be grouped by type of Luminaire controlled. Enforcement Agency: Systems Acceptance. Before Occupancy Permit is granted for a newly constructed building or space or when ever new lighting system with controls is installed in the building or space shall be certified as meeting the Acceptance Requirements. The LTG -2A form is not considered a complete form and is not to be accepted by the enforcement agency unless the boxes are checked and/or filled and signed. In addition, a Certificate of Acceptance forms shall be submitted to the enforcement agency that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of (SS) 10-103(b) of Title 24 Part 6. The field inspector must receive the properly filled out and signed forms before the building can receive final occupancy. A copy of the LTG -2A for each different lighting luminaire control(s) must be provided to the owner of the building for their records. Certificate of Acceptance Luminaires Controlled OLTG-2A y Outdoor Y ° E E Lighting Acceptance Equipment Requiring Testing Description w. o z o U Location Tests 10 20 (4P) RELAY CONTACTOR 2 ADJACENT T,0 PANEL "HP" 30 (12P) RELAY CONTACTOR 1 ADJACENT TO PANEL "HP" PHOTOCELL PHOTOCELL 3 ROOF TOP TC TIMECLOCK 3 ADJACENT TO PANEL "HP" 1. Insert: OMS for Outdoor Motion Sensor; OLSC for Outdoor Lighting Shutoff Controls; OP for Outdoor Photocontrol; ATS for Astronomical Time Switch; and STS for Standard (non -astronomical) Time Switch acceptance. 2008 Nonresidential Compliance Forms AUGUST 2009 CERTIFICATE OF COMPLIANCE (Part 4 of 4) OLTG-1-C PROJECT NAME RETAIL SHOPS - LA QUINTA VILLAGE DATE 06-03-10 ALLOWED AND INSTALLED OUTDOOR LIGHTING POWER Lighting Wattage 2008 Nonresidential Compliance Forms Lighting Wattage Power Allowance Lighting power allowance for general hardscape A (from OLTG-2C Page 1 of 3) Specific application lighting wattage allowance per unit length B (from OLTG-2C Page 1 of 3) Specific application wattage allowance for ornamental lighitng ' C (from OLTG-2C Page 1 of 3) Specific application wattage allowance per application D (from OLTG-2C Page 2 of 3) Specific application lighting wattage allowance per area ` 1430 E (from OLTG-2C Page 2 of 3) Additional lighting power allowance for ordinance requirements F (from OLTG-2C Page 3 of 3) G Total Allowed Wattage = Sum of rows A through F: 1430 Total Installed Watts (from Luminaire Schedule) 1430 H (from OLTG-1C Page 2 of 4) Complies if Installed Wattage in row H is less than or equal to the Total Installed Wattage in row G ®, Yes O No 2008 Nonresidential Compliance Forms OUTDOOR LIGHTING WORKSHEET (Page 2 of 3) OLTG-2-C 2009 2008 Nonresidential Compliance Forms AUGUST PROJECT NAME RETAIL SHOPS — LA QUINTA VILLAGE � DATE 06-03-10 D. SPECIFIC APPLICATION LIGHTING WATTAGE ALLOWANCE PER APPLICATION DETERMINE WATTAGE ALLOWANCE DESIGN WATTS ALLOWANCE A B C� H D E F G H I J Specific Lighting Application • Number of Luminaires ' Specific Applicatio Allowance (watts) Wattage Allowance (B x C) Luminaire Symbol Luminaire Type Luminaire Quantity Watts per Luminaire Design Watts (G x H) Allowed Watts Minimum of (D x I) ' - Enter total into OLTG-1C; Page 4 of 4; Row D; Specific Application Wattage Allowance Per Application E: SPECIFIC APPLICATION LIGHTING WATTAGE ALLOWANCE PER AREA - DETERMINE WATTAGE ALLOWANCE LUMINAIRE TYPE DESIGN WATTS A B C D E F G H f J Specific Lighting Application Illuminated Area of Application Specific Applicatio Wattage Allowance Allowance (watts per ff) (B x C) Code for Luminaire 'Type Luminaire Type Luminaire Quantity .Watts per Luminaire Design Watts (G x H) Allowed Watts Minimum of (D x I) PEDESTRIAN 3780 0.17 643 WALL PACK tOOMH 4. 110 440 440 PEDESTRIAN 2100 0.17 357 WALL PACK 10OMH 3 .110 330. 330 DRIVEWAY 3780 0.15 569 WALL PACK t OOMH 3 110. 330 330 DRIVEWAY 2800 .0.15 420 WALL PACK t 00MH 3 110 330 330 Enter total into OLTG-1 C; Page 4 of 4; Row E; Specific Application Lighting Wattage Allowance Per Area 1430 CERTIFICATE OF COMPLIANCE (SIGN LIGHTING) (Page 1 of 2) SLTG-1 C NAME RETAIL SHOPS PHASE OF CONSTRUCTION ® NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATwN LA QUINTA VILLAGE FUNCTION TYPE ® OUTDOOR SIGNS ❑ INDOOR SIGNS ADDRESS 50-991 Washington Street DATE: I COMPLIANQUWJBOD USED ® MAXIMUM ALLOWED La Quints California 92253 06-03-10 LIGOO ❑ ALTERNATE LIGHTING SOURCES DOCUMENTATION AUTHOR'S DECLARATION STATEMENT �� �O 'Lc, • 1 CERTIFY THAT THIS CERTIFICATE OF COMPLIANCE DOCUMENT tD IS� E ANI TE. NAME LINO PALMIERI SI az RE E 8965 I DATE 06-03-10 COMPANYPALMIERI & ASSOCIATES, INC.KPI ADDRESS 232 N. LAKE AVENUE SUITE #210 y�F %E CITY/STATE/ZIP PASADENA, CA. 91101 (626) 440-1313 PRINCIPAL LIGHTING DESIGNER'S DECLARATION STATEMENT I AM ELIGIBLE UNDER DIVISION 3 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODE TO ACCEPT RESPONSIBILITY FOR THE LIGHTING DESIGN. • THIS CERTIFICATE OF COMPLIANCE IDENTINES THE LIGHTING FEATURES AND PERFORMANCE SPECIFICATIONS REQ COMPLUWCE WITH TITLE 24, PAGES 1 AND 6 OF THE CALIFORNIA CODE OF REGULATIONS. FES • THE DESIGN FEATURES REPRESENTED ON THIS CERTIFICATE OF COMPLIANCE ARE CONSISTENT WITH TH P CUMENT THIS DESIGN ON THE AGENCY FOR APPROVAL WITH OTHER APPLICABLE COMPLIANCE FORMS, WORKSHEETS, CALCULATIONS, PLANS AND SPECIFICATIONS ED At, THIS BUILDING PERMIT APPLICATION. NAME: LINO PALMIERI SIGNATURE E 8965 133(a)3. ALL OUTDOOR SIGNS ARE CONTROLLED WITH A DIMMER THAT PROVIDES THE ABILITY TO AUTOMATICALLY REDUCE SIGN POWER BY A MINIMUM OF COMPANY: PHONE 440-1313 PALMIERI & ASSOCIATES, INC. F. � (626 ) ADDRESS' 232 N. LAKE AVENUE SUITE #210 E v 8965 CITY/STATE/ZIP: PASADENA, CA. 91101 06-03-10 SIGN MANDATORY MEASURES INDICATE LOCATION ON BUILDING PLANS OF MANDATORY SIGN MEASURES NOTE BLOCK: MANDATORY SIGN LIGHTING CONTROLS YES NO 133(a)1. ALL SIGNS WITH PERMANENTLY CONNECTED LIGHTING ARE CONTROLLED WITH AN AUTOMATIC TIME SWITCH CONTROL THAT COMPLIES WITH THE ❑ APPLICABLE REQUIREMENTS OF 119. 133(a)2. ALL OUTDOOR SIGNS ARE CONTROLLED WITH A PHOTO CONTROL OR OUTDOOR ASTRONOMICAL TIME SWITCH CONTROL. ® ❑ 2 EXCEPTION TO 133(a)2. OUTDOOR SIGNS ARE IN TUNNELS OR LARGE COVERED AREAS THAT REQUIRE ILLUMINATION DURING DAYLIGHT HOURS. ❑ D 133(a)3. ALL OUTDOOR SIGNS ARE CONTROLLED WITH A DIMMER THAT PROVIDES THE ABILITY TO AUTOMATICALLY REDUCE SIGN POWER BY A MINIMUM OF 65 PERCENT DURING NIGHTTIME HOURS. ❑ EXCEPTION 1 TO 133(a)3. SIGNS ARE ILLUMINATED FOR LESS THAN ONE HOUR PER DAY DURING DAYLIGHT HOURS. 3 EXCEPTION 2 TO 133(a)3. OUTDOOR SIGNS ARE IN TUNNELS OR LARGE COVERED AREAS THAT REQUIRE ILLUMINATION DURING DAYLIGHT HOURS. ❑ EXCEPTION 3 TO 133(a)3. ONLY METAL HALIDE, HIGH PRESSURE SODIUM, COLD CATHODE, OR NEON LAMPS ARE USED TO ILLUMINATED SIGNS OR PARTS OF g ❑ SIGNS. 133(a)4. AN ELECTRONIC MESSAGE CENTER (EMC) HAVING A NEW CONNECTED LIGHTING POWER LOAD GREATER THAN 15 KW HAS A CONTROL INSTALLED IS DEMAN RESPONSE SIGNAL THAT IS SENT OUT BY TH E Y N N/A CAPABLE OF REDUCING THE LIGHITNG POWER BY A MINIMUM OF 30 PERCENT WHEN RECEIVING A ❑ 4 LOCAL UTILITY. EXCEPTION TO 133(a)4. THE EMC IS REQUIRED BY A HEALTH OR LIFE SAFETY STATUE, ORDINANCE, OR REGULATION, INCLUDING BU NOT LIMBED TO EXIT Y N NIA SIGNS AND TRAFFIC SIGNS. 2008 Nonresidential Compliance Forms August 2009 s? r CERTIFICATE OF COMPLIANCE AND FIELD INSPECTION ENERGY CHECKLIST (SIGN LIGHTING) (Page 2 of 2) SLTG-1 C PROJECT NAME RETAIL SHOPS - LA QUINTA VILLAGE DATE 06-03-10 • COMPLIANCE METHOD MAXIMUM ALLOWED LIGHTING POWER A• B C D E F G H I J p O O O M fA • _Z m DESCRIPTION OR LOCATION AND PLAN, LOCATION ALLOWED WATTS DESIGN WATTS' COMPLIES? YIN LIGHT SOURCE FIELD INSPECTOR2 "' UL ... Q Q Z N OWJC9 � J W J J I. -I Q "Q Q Z � W � W F- X J z w Ja --LL W LL� O W N J U � W O K J U N O Z LL F- ~ O Q (q W_ � LL !;O V1 O � N O � J a' W LL In (n J W W Q 0. W N LL • TA o_ J LL SO � EXTERIOR E2.1 450 I 12 5400 3000 .YES 5,. ❑ ❑ O ` ❑ O O TOTAL SIGN AREA: M -. 1. DESIGN WATTS= TOTAL CONNECTED LIGHTING LOAD INSTALLED IN THE SIGN, INCLUDING POWER USED BY LAMPS, BALLASTS, TRANSFORMERS, POWER SUPPLIES, ETC. 2. IF FAIL THEN DESCRIBE ON PAGE 2 OF THE INSPECTION CHECKLIST FORM AND TAKE APPROPIRATE ACTION TO CORRECT. VERIFY BUILDING PLANS IF NECESSARY. USE ADDITIONAL SHEETS IF NECESSARY. THE SIGN(S) IDENTIFIED ABOVE; USE ONLY ONE OR MORE OF THE FOLLOWING TECHNOLOGIES: (LIST ALL APPLICABLE NUMBERS THAT APPLY IN COLUMN I ABOVE 1 HIGH PRESSURE SODIUM LAMPS - 2 PULSE START OR CERAMIC METAL HALIDE LAMPS SERVED BY A BALLAST WITH > 88% EFFICIENCY 3 PULSE START METAL HALIDE LAMPS THAT ARE < 320 WATTS, ARE NOT 250 WATT OR 175 WATT LAMPS, AND ARE SERVED BY A BALLAST WITH > 80% EFFICIENCY 4 NEON OR COLD CATHODE LMAPS WITH TRANSFORMER OR POWER SUPPLY EFFICIENCY > 75 % WITH RATED OUTPUT CURRENT < 50 MA 5 NEON OR COLD CATHODE LMAPS WITH TRANSFORMER OR POWER SUPPLY EFFICIENCY > 68% WITH RATED OUTPUT CURRENT < 50 MA ' 6 FLUORESCENT LAMPS WITH A MINIMUM COLOR RENDERING INDEX (CRI) OF 80 - • 7 LIGHT EMITTING DIODES (LEDs) WITH A POWER SUPPLY WITH > 80% EFFICIENCY - 8 SINGLE VOLTAGE LED EXTERNAL POWER SUPPLIES DESIGNED TO CONVERT 120 VOLTAC INPUT INTO LOWER VOLTAGE DC OR AC OUTPUT, HAVING A NAMEPLATE OUTPUT POWER LESS THAN OR EQUAL TO 250 WATTS, AND CERTIFIED TO THE ENERGY COMMISSION AS COMPLYING WITH THE APPLICABLE REQUIREMENTS OF THE APPLICANCE EFFICIENCY REGULATIONS TITLE 20 9 COMPACT FLUORESCENT LAMPS THAT DO NOT CONTAIN A MEDIUM SCREW BASE SOCKETS (E24/E26) 10 ELECTRONIC BALLASTS WITH A FUNDAMENTAL OUTPUT FREQUENCY> 20 KHZ FIELD INSPECTOR NOTES OR DISCREPANCIES 2008 Nonresidential Compliance Forms August 2009 0 CERTIFICATE OF COMPLIANCE AND FIELD INSPECTION ENERGY CHECKLIST (SIGN LIGHTING) (Page 2 of 2) SLTG-1 C PROJECT NAME RETAIL SHOPS - LA QUINTA VILLAGE DA1E 06-03-10 COMPLIANCE METHOD A B MAXIMUM ALLOWED LIGHTING POWER C D E F G H I J DESIGN COMPLIES? LIGHT. FIELD VW ALLOWED WATTS WATTS' YIN SOURCE INSPECTOR2 N O-- LU W Z O m J w aN a Q F-.. N Z Z Z Z �. W 3a M W � Z JF- J J.. 3' JLU Qp z C� LU UJ ~ HJ - N W - JQ O d 0 O`0 O OR LOCATION AND PLAN w vLOCATION L � m O. W Q QDESCRIPTION . _ y U. IL IL ❑ ❑ ❑ EXTERIOR E2.1 450 I 12 5400 3000 YES 5 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ♦ TOTAL SIGN AREA: - - 1. DESIGN WATTS= TOTAL CONNECTED LIGHTING LOAD INSTALLED IN THE SIGN, INCLUDING POWER USED BY LAMPS, BALLASTS, TRANSFORMERS, POWER SUPPLIES, ETC, Z IF FAIL THEN DESCRIBE ON PAGE 2 OF THE INSPECTION CHECKLIST FORM AND TAKE APPROPIRATE ACTION TO CORRECT. VERIFY BUILDING PLANS IF NECESSARY. USE ADDITIONAL SHEETS IF NECESSARY, THE SIGN(S) IDENTIFIED ABOVE; USE ONLY ONE OR MORE OF THE FOLLOWING TECHNOLOGIES: (LIST ALL APPLICABLE NUMBERS THAT APPLY IN COLUMN I ABOVE 1 HIGH PRESSURE SODIUM LAMPS 2 PULSE START OR CERAMIC METAL HALIDE LAMPS SERVED BY A BALLAST WITH > 88% EFFICIENCY 3 PULSE START METAL HALIDE LAMPS THAT ARE < 320 WATTS, ARE NOT 250 WATT OR 175 WATT LAMPS, AND ARE SERVED BY A BALLAST WITH > 80% EFFICIENCY 4 NEON OR COLD CATHODE LMAPS WITH TRANSFORMER OR POWER SUPPLY EFFICIENCY >.75% WITH RATED OUTPUT CURRENT < 50 MA 5 NEON OR COLD CATHODE LMAPS WITH TRANSFORMER OR POWER SUPPLY EFFICIENCY > 68% WITH RATED OUTPUT CURRENT < 50 MA 6 FLUORESCENT LAMPS WITH A MINIMUM COLOR RENDERING INDEX (CRI) OF 80 7 LIGHT EMITTING DIODES (LEDS) WITH A POWER SUPPLY WITH> 80% EFFICIENCY 8 SINGLE VOLTAGE LED EXTERNAL POWER SUPPUES DESIGNED TO CONVERT 120 VOLT AC INPUT INTO LOWER VOLTAGE DC OR AC OUTPUT, HAVING A NAMEPLATE OUTPUT POWER LESS THAN OR EQUAL TO 250 WATTS, AND CERTIFIED TO THE ENERGY COMMISSION AS C04PL•YING WITH THE APPLICABLE REQUIREMENTS OF THE APPLICANCE EFFICIENCY REGULATIONS TLE 20 9 COMPACT FLUORESCENT LAMPS THAT DO NOT CONTAIN AWEDIUM SCREW BASE SOCKETS (E24/E26) 10 ELECTRONIC BALLASTS WITH A FUNDAMENTAL OUTPUT FREQUENCY> 20 KHZ FIELD INSPECTOR NOTES OR DISCREPANCIES 2008'Nonresidential Compliance Forms August 2009