Loading...
05-1161 (SFD)P.O. BOX 150.4 u& 78-495 CALLE TAMPICO' LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT . . BUILDING PERMIT Application Number. 05'=0:0:0016161 .", - Owner: Property Address 53188 VIA`IPP:acIO ALEX PARKER APN: 772-550-.050- - - - 12 DOVER PLACE Application description: DWELLING - SINGLE FAMILY DETACHED MANHATTEN BEACH Property Zoning: LOW DENSITY RESIDENTIAL MANHATTAN BEACH; CA 90266 Application valuation: 418024 Contractor: Applicant: Architect or Engineer: JACOBS HOMES INC, PETER P.O. BOX 692 LA QUINTA, CA 92247 (760)777-9921 LiC. No.: 799449 — — — — — — — — — — — — JBusines ED CON R CTOR'S DECLARATION I hereby affirm under penalty of pcans u der provisions of Chapter 9 (commencing with Section 7000) of Division 3 of throle ' Is Code, and my License is in full force and"effect. License Class: B License No.: 799449 /date: ontractor. / OWN -BUILDER DECLARATION - I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the . following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State - . License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or ' that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031 .5 by .any applicam,for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500).: 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and - the.structure is not intended or offered for'sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If,. however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). ( 1 "I am exempt under Sec. , B.&P.C. for this reason Date: Owner: . CONSTRUCTION LENDING AGENCY I hereby'affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.)• - Lender's Name: Lender's Address: - LQPERi11IT VOICE (760) 777-7012 FAX (760)'777-7011 'INSPECTIONS (760) 777-7153 Date: . 8/18/05. -WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided - for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I7. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor 'Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: - Carrier HRH -INSUR Policy Number 176983305 _ I certify that, in the pe/shoe4me a of the work f which this permit is issued, I shall not employ any person in any manto become sub' t to the workers' compensation laws of California, and agree that, if I subje t the workers' compensation provisionsof Section of the Labor all h t mply with those provisions. - iDate: //(J Applicant: - WARNING: FAILURE TO SECURE WORKERS' CONSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTI AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director.of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject . permit to cancellation. - I certify that I have read this application and state that.the above i ma 'on is c ct. I agree to comply with all city and county ordinances and state laws relating to building co uct , a eby authorize representatives of this county y to enter upon the ove-mentioned property for i ec ' s. - gate: ��/ ature (Applicant or Agent): LQPERA4IT Application Number •. 05-00001161 Permit . . . BUILDING PERMIT Additional desc . Permit Fee 1756.00 Plan Check Fee 1141.40 Issue Date . . . . Valuation 418024 Expiration Date 2/14/06 Qty. Unit Charge Per Extension BASE FEE 639.50 319.00 3.5000 THOU BLDG 100,001-500,000 1116.50 Permit ELEC-NEW RESIDENTIAL Additional desc . Permit Fee 196.50 Plan Check Fee 49.13 Issue Date Valuation . . 0 Expiration. Date 2/14/.06 Qty Unit Charge Per Extension BASE FEE 15.00 4670.00 .0300 ELEC NEW RES - MULTI FAMILY 140.10 1320.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 26.40 1.00 15..0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit GRADING PERMIT 4 Additional desc . Permit Fee 15.0.0 Plan Check Fee 00 _ Issue Date . . Valuation . . 0 Expiration Date 2/14/06 Qty Unit Charge .Per .Extension ------------------------------------------=-------------------- BASE FEE ------- 15.00 ------ Permit . . MECHANICAL - Additional desc . " Permit Fee . . . 150.50 Plan Check Fee..37:63 Issue Date Valuation. •0 Expiration Date 2/14/06 Qty Unit Charge Per Extension BASE FEE 15.00 " 5.00 9.0000 -EA MECH FURNACE <=100K 45.00 5.00 9.0000 EA. MECH B/C <=3HP/100K BTU 45.00 . 6.00 .6.5000 EA MECH VENT FAN 39.00 1.00 6.5000 EA MECH EXHAUST HOOD ----------------- 6.50 LQPERA4IT f - - Application Number . . . . . 05-00001161 Permit . . . PLUMBING Additional desc . Permit Fee .... 219.75 Plan Check Fee 54.94 Issue Date _ Valuation 0 Expiration Date 2/14/06 Qty Unit Charge Per Extension. BASE FEE 15.00 22.00 - 6.0000 EA PLB FIXTURE 132.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 .1.00 6.0000 EA PLB ROOF DRAIN 6.00 2.00 7.5000. EA PLB WATER HEATER/VENT 15.00 1..00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM.• 9.00 13.00 .7500 EA PLB GAS PIPE >=5 9.75 1.00 15-.0000 EA PLB GAS METER 15.00 -------------------------------------------------------- Special:Notes and Comments 46.70 SQ. FT. SFD THIS PERMIT DOES NOT INCLUDE POOL & SPA BLOCK WALLS OR - DRIVEWAY APPROACH.August 18, 2005 3:55:22 'PM JJOHNSON _ Other. Fees ART IN PUBLIC PLACES -RES 545.06 - DIF COMMUNITY CENTERS -RES 97.00. DIF CIVIC CENTER - RES_. 366.00 ENERGY REVIEW FEE 114.14 ~ DIF FIRE PROTECTION -RES,' 97.00 GRADING PLAN -CHECK FEE 0.0 'DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 , -STRONG MOTION (SMI) -. RES 41.80 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary -Charged Paid Credited Due Permit Fee Total -- ---------- ---------- ---------- 2337.75 00.E .00 2337..75 -Plan Check Total 1283.10 750.00 .00 533.10 Other Fee Total 3106.00 .00 .00 3106.00 Grand Total 6726.85 750.00 .00 5976.85 LQPERMIT i9uilding Address caner rrIpu Mailing Address ContW1 ?ftdress to . ap Ti 4 4 a " n� 5 3ln p v P.O. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 n L, J 81040=1116 -Ts' ii) NNA . &.Classif. I Lic. # Designers LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than rive hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, Slate, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CONST.IJ�Ci� Legal Description:re 2--1 Y9 4 X3/v S Project Description r — V J c'7 Size 1� T Stories ( J Uni NewV Add ❑ Alter ❑ Repair ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading 1. Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE Coachella Valley. -Unified School District . .83-733 Avenue 55, Thermal, CA 92274 (760).398-5909 - Fax (.760)• 398-1224 This Box For District Use Only . T)F.VF.T.0PF.R FFFS PATI AREA:, AMOUNT LEVEL ONE AMOUNT*;' LEVEL TWO AMOUNT: M ITIGATION'AMOUNT: COMM/ ND. AMOUNT: DATE: - RECEIPT: CHECK#: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Alex Parker (Residence @Hideaway) Date: January 24;.2006 Owner's Name:. Alex Parker Phone No. (760) 880-1761 Project Address: 534$8 Via Palacio, La Quinta, CA Project Description:,.. 1 Single Family Residence APN: 772-550-050 Tract #i Lot #'s: Type of Development: Residential:. XX - Commercial Industrial Total Square Feet of Building Area: . 4,670 sq. Ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is:authorizqfto sign behalf of the owner/developer. Dated: 01/24/06 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL'BE SATISFIED IN ACCORDANCE 'WITH ONE OF -THE FOLLOWING: ' (CIRCLE'ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620• 65995" Approval Prior to 1%1/87 Requirement Number of Sq.Ft. 4,670 Amount per Sq.Ft... $ . 2.88. Amount Collected $. 13;449.60 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt.;. Business Services Certificate issued by: Leticia C.,Torres, Facilities Clerk Signature NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMEN OWE ES Section 66026 of the Government Code asserted by Assembly Bill 3081,'effective January 1; 1997, requires that this Dist ' provide (1) a written'notice to the project appellants at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 660206f the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the.payment of the fees or performance of any'other requirements as described in section 66020 of the Government code. Additionally, the amountof the fees.imposed is as herein 'set:forth, whether payable at this time or in whole or.in. part.p*rior to. issuance of a Certificate of Occupancy.. As in,the latter, ,the 90 'days starts on ,the date hereof. This Certificate of Compliance is valid for thirty. (30) days from the date of issuance. Extension will be granted only for goodcause, as determined by the School District, and up to three'(!) such extensions may be granted. At such time as'this Certificate expires, if a building permit has not been issued for the project that is the subject of this.Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. vi.V:c/mydocs/devrees/certificate of compliance form fabler"1-0 IJSGdoc 1/16/037 occ u 2003-072530 blaa N,ATIONAL'l[�'I LE COMPANY Page I of 4 Doa T Tax aid WBDIVISIONMP 1 Recorded to Official Record County of Riverside '%IiEN RECORDED MAIL TO' Gary L. Oreo 06saassaor, County Clerk 6 Recorder Mr. & Mrs. Parker 12 mover Place I III Manhattan Beach, Ca 90266 . 1i illllllil ililii Ilii Illilll ISI MAIL TAX STA'T'EMENT, T0: SAME AS ABOVE M s u vxca =t on Pcca „,C. sk -10 ` COPr lo+m R;.- ;�y,a Exrw DOCUMENT TRANSFER TAX $609.40 XX Computed on the comideration or value of property conveyed; ORMA Compute'd on the consideration. or value less liens or encumbrances remaining at the time of sale. Signature of Declarant or Agent determining tax - Firm Name GRANT (DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company ("Grantor"), hereby 0&-NNT(S) to Alex Parker and Cierlinde Parker, husband and wife as Joint Tenants ("Grantee"), the real property located in the City of La Quinta, County of Riverside, State df Cafifornia, described as' See Legal Description attached hereto and incorporated herein as Exhibit "N', SUBJECT TO all matters of record including, without limitation, the covenants and agreements described in Exhibit "A" attached Hereto. Dated: January 20, 2003 ND LA'QUINTA PARTNERS, LLC, limited a Delaware liability company By, Nationwide Realty Investors, Ltd., an Ohio limited .liability company its managing rx ber I BY: ol os h L. Arenson Authorized Representative S'T.A,rE OF California ) ' ) SS. COUNTY Ok R,ivirside ) i _ On _�I' 2003, before me, the undersigned, a notary public in and for said State, personally appe ed Joseph L. Areason s (or proved to me on the basis of satisfactory evidence) to be the persons) whose ;aame(s) is subscribed to the within instrument and acknowledged to me that he executed the same in his authorized capac;ity(ies), and that by his signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument.. WITNESS MY HAl' D AND OFFICIAL SEAL: ff Signature _ t -,sY9 (,(, &2 [.SEAL] KATHRYN L. HUNTER Commisairn N 4382692 Nototy Public - Wf0ml0 > Rlvenji County my Comm. I o a$ Nov 1. ?Oo6 gallo 1 •LAK+27969.1 2 Legal Descri ion parcel No. l: , Lot 241 (the "Lot") of Amended Tract No 29894-2 as shown on a Subdivision Map (the "Map") recorded on December 12, 2002, in Book 327, Pages 56 to W inclusive, of Maps, in the Office of the Riverside County Recorder. EXCEPTr NG AND RESERVING THEREFROM TO GRANTOR, and its successors, assigns, invitees, licensees and employees, together with the right to grant and transfer all or a portion ofthe same, all easements and rights for access, ingress, egress, encroachment, maintenance, drainage, support,. and for other purposes over the Association Maintenance Areas and other portion of the Lot, reserved to Grantor in the following instrument& I . The Amended and Restated Declaration of Covenants, Conditions and Restrictions and Reservation of Casements for The Hideaway Owners Association (as amended or supplemented, the "Declaration"), recorded on December 13, 2002, as Instrument No. 2002- G 3 of Of iciral Records of Riverside County, California (tb.e `�O�cial Records"); FURTHER RESERVING THEREFROM; the right to enter the Lot for a term of twelve (12) months following the recordation of this Grant Deed, to complete and repair any improvements or landscaping located thereon as determined necessary by Grantor, in its sole discretion, in order to comply with requirements for the recordation of the Final Tract Map, the grading of said Tract and/or in compliance with the requirements of applicable governmental agencies. Such entry by Grantor shall be preceded by reasonable notice to Grantee before such entry. if this reservation of right of entry is not complied with. by Grantee, Grantor may enforce this right of entry in a court of law. Grantee shall be responsible for all damages arising out of said breach including attorneys' fees and court costs. This reservation of right of entry shell automatically expire twelve (12) months from the recordation of this Grant Deed, Parcel,, Flo. �; Nonexclusive easements for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as described in the Declaration. SUBJECT TO; 1. Nondelinquent general, special and supplemental rear property taxes and assessments. 2. All other covenants, conditions, restrictions, reservations, easements, rights and rights-of-way of record including, without limitation, the Declaration and the.Map for Tract No. 29894-2, f2 439N��q 1 •LAJ627969.1 3 Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in this Grant Deed, (b) grants to Grantor and The Hideaway Owners Association such powers and rights as are set forth in the Declaration ,and (c) accepts, covenants and agrees to be bound by and assume performance of all of the applicable provisions and requirements set forth in the Declaration, including Section 13.15 establishing the'procedure for resolving disputes with. Grantor, and the notice, which provisions and requirements are acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be perfonned by Grantee under the Declaration. The restrictions on use and occupancy of the Lot are set forth in the Declaration to which this Granit Deed is specifically and expressly made subject. GRANTEE HEREBY ACCEPTS AND APPROVES THE. FOREGOING, granting unto Granter and The Hideaway Owners Associat' n such powers and rights which are set forth in the Declaration defined above, on _ , _ 2003. STATE OF C COUNTY, OF \..o•� �n t`t� On 775: 4?,a at 111, 2003, before me, the undersigned, a notaty public in and for said State, personally appeared _ A\,j. e Ae Q a,N,ct personally known to me (or proved to Pie on the basis of satisfactory evidence) to be the person(s) whose name(s) is/Am subscribed to the within instrument and acknowledged to me that he/she/th executed the same in his/ authorized capachy(ies), and that by his/her/ signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS MY HAND AND OFFICIAL. SEAL. aHeRRI L GORE Signature � � [SEAL]canvniarjansMOM P ��IPR 11111 fill 1111111 fill Iilli4e7.E 4 k»A 1 -LA 627969. ), 4 v na�t�i42fQ,,C� • o -o Certificate of Occupancy .. I.cos.�R,Tm ot C� OF T9wBuildings & Safety Department This Certificate is issued pursuant to the requirements of Section 109.6f the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. Use classification: SFD ;Occupancy Group: R3 Owner of Building: ALEX PARKER L All - Building Official BUILDING ADDRESS: 53188 VIA PALACIO Type of Construction: VN POST IN A CONSPICUOUS PLACE Building Permit No.: 05-1161 Land Use Zone:. RL Address: 12 DOVE PLACE City, ST, ZIP: MANHATTAN BEACH CA 90266 By: EDDIE MUIR Date: 07-27-07 - Project Designer: - The Woodard Group 80-880 Vista Bonita Trail '•� La Q u i nta, CA 92253 760-775-7088' Y Le r� Report Prepared By: Gina Rose • G. R. Rose CAD Design . 42335 Washington Suite F #330 Palm Desert, CA 92211 (760) 345-4859 ; ,. F Y OF LA QUINTA DING & SAFETY DEPT. APPROVED ,. Job Number:,CONST UC ION LDA;TI�4 — .` Date: 0.107he EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number: User Number: 5862 �. a x . t q' ' i C 0 • Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Parker Residence Fenestration 7/28/2005 Project Title t, Date Lot 241, The Hideaway La Quinta Assembly Project Address Type Building Permit # G.R. Rose CAD Design (760) 345-4859 Plan check /Date Documentation Author Telephone - - Computer Performance 15 - Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION - n/a Total Conditioned Floor Area: 4,670 fid Average Ceiling Height: 9.8 ft Total Conditioned Slab Area: 4,670 ft2 - - Building Type: Solid Wood Door Wood . (check one or more) Exterior Door ❑ X❑ Single Family Detached ^' ' ❑ Addition (Southeast) ❑ Single Family Attached ❑ Existing Building ' 0.52 ❑ Multi -Family ❑ Existing Plus Addition` x❑ * Front Orientation: (Northwest) 315 deg Floor Construction Type: ®Slab Floor Number of Dwelling Units: 1.00 ' Number of Stories: 1- ❑ Raised Floor LSUILUINU bNtLL INJULA I IUN Orientation Area Fenestration 'Exterior ' Const. t, Component Frame Assembly Location/Comments Type Type U -Value '(attic, garage, typical, etc.), R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof R-21 Wall (W.21.24.16) Wood 0.059 Exterior Wall Slab On Grade r n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slali w/R-0.0 Perimeter Insulation Solid Wood Door Wood . 0.387 Exterior Door FENESTRATION Ch�rlinn rinii�nc Type Orientation Area Fenestration 'Exterior ' Overhang Side Fins SF U -Factor SHGC Shadin Yes / No Yes / No Left (Northeast) 51.0 0.64 0.53 Bug Screen Q ❑ ❑ X❑ Rear (Southeast) 102.0 0.64 0.53 Bug Screen Q ❑ ❑ X❑ Rear (Southeast) 33.8 0.45 0.52 Bug Screen x❑ ❑ ❑ X❑ Rear (Southeast) 40.0- 0.55 r " 0.48 Bug Screen Q ❑ ❑ X❑ Right (Southwest) 18.8 0.45 0.52 Bug Screen ❑ X❑ ❑ X❑ Right (Southwest) 12.5 0.55-'_ 0.48 t Bug Screen ❑ X❑ ❑ X❑ Right (Southwest) 241.0 0.45' 0.52 Bug ScreenX❑ ❑ ❑ X❑ Left (Northeast) 30.0 .0.55 0.48 Bug Screen ❑ X❑ ❑ X❑ Left (Northeast) 30.5 0.45 _ 0.52 Bug Screen ❑ x❑ ❑ x❑ Left (Northeast) 100.0 0.47 " 0.48 Bug Screen X❑ ❑ ❑ X❑ Rear (Southeast) 21.0 4 0.45 0.52 Bug Screen ❑ X❑ ❑ X❑ Rear (Southeast) 165.0 0.47 0.48 Bug Screen X❑ ❑ X❑ ❑ Run Initiation Time: 07/28/05 13:55:53 Run Code: 1122584153 Ener Pro 3.1 By Ener Soft User Number: 5862. Job Number. Pa e:3 of 46 i Certificate of Compliance: Residential (Part 1 of 2) CF -1 R • Fenestration Parker Residence Overhang Side Fins 7/28/2005 Project Title SF Date Lot 241. The Hideaway La Quinta Yes / No Project Address / No Building Permit # G.R. Rose CAD Design _ (760) 345-4859 Plan check / Date Documentation Author Telephone Bug Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Front (Northwest) Total Conditioned Floor Area: 4,670 ft2 Average Ceiling Height: 9.8 ft Total Conditioned Slab Area: 4,670 ft2 Screen Building Type: ❑ ❑ (check one or more) , (Northwest) X❑ Single Family Detached ❑ Addition 0.52 ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition ❑ Front Orientation: (Northwest) 315 deg Floor Construction Type: ,FX] Slab Floor Number of Dwelling Units: 1.00 ` 0.48 Number of Stories: 1 ❑ Raised Floor ❑ X❑ ❑ • Component Type Const. Frame Assembly , Location/Comments Type U -Value (attic, garage, typical, etc.) FENESTRATION Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor •SHGC Shading Yes / No Yes / No Rear (Southeast) 136.6 0.47 0.48 Bug Screen X❑ ❑ ❑ X❑ Front (Northwest) 42.5 0.64 0.53 Bug Screen X❑ ❑ ❑ X❑ Front (Northwest) 89.8 0.45 0.52 Bug ScreenX❑ ❑ X❑ ❑ Front (Northwest) 68.0 0.47 0.48 Bug Screen X❑ ❑ X❑ ❑ Front (Northwest) 29.8 0.45 0.52 Bug ScreenX❑ ❑ ❑ X❑ Left (Northeast) 57:3. 0.55 0.48 Bug ScreenX❑ ❑ ❑X❑ Right (Southwest) 51.0 0.64 ` 0.53 Bug Screen ❑ o Ela Right (Southwest) 30.0 0.55 0.48 Bug ScreenX❑ ❑ ❑ X❑ Front (Northwest) 5.1 0.45 0.52 r Bug Screen ❑ X❑ ❑X❑ Front (Northwest) 63.8 .0.64 0.53 Bug Screen ❑ X❑ ❑X❑ Left (Northeast) 34.5 0.45 0.52 Bug ScreenX❑ ❑ ❑X❑ Left (Northeast) 15.0 0.55 0.48 Bug ScreenX❑ ❑ X❑ ❑ Run Initiation Time: 07/28/05 13:55:53 Run Code: 1122584153 Ener Pro 3.1 By Ener Soft User Number: 5862 Job Number: Pa e:4 of 46 0 Certificate of Comaliance: Residential , (Part 1 of 2) CF -1 R • • Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) FFNFSTRATION • Churl �.,., nnvinnc Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Parker Residence Yes / No 7/28/2005 Project Title x❑ ❑ Date Lot 241, The Hideaway La Quinta Project Address ❑ ❑ Building Permit # G.R. Rose CAD Design (760) 345-4859 Plan Check / Date Documentation Author Telephone ❑ ❑ Computer Performance 15 Field check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION ❑ ❑ Total Conditioned Floor Area: 4,670 ft2 Average Ceiling Height: 9.8 ft Total Conditioned Slab Area: 4,670 ft2 El F1 Building Type: 1:1 1:1 El El (check one or more) ❑ ❑ ❑ ❑ X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Page: 5 of 46 Front Orientation: (Northwest) 315 deq Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor • • Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) FFNFSTRATION • Churl �.,., nnvinnc Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Left (Northeast) 25.5 0.64 0.53 Bug Screen ❑ X❑ x❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1:1 1:1 El 1:1 El El El F1 1:1 1:1 El El ❑ ❑ ❑ ❑ Run Initiation Time: 07/28/05 13:55:53 Run Code: 1122584153 Ener Pro 3.1 By Ener Soft User Number: 5862 Job Number: Page: 5 of 46 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Parker Residence 7/28/2005 Project Title Date HVAC SYSTEMS' Note: Input Hydronic or Combined Hydronic data underwater Heating Systems, except Design Heating Load. Distribution I , Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnare 80% AFUE Ducts in Attic 4.2 Setback Master Suite 80% AFUE Ducts in Attic Central Furnace 80% AFUE Ducts in Attic 42 4.2 Setback I iving Area Setback Guest Bedrooms CPntral Furnace 80% AFUE Ducts in Attic . 4.2 Setback Guest Suite Cooling Equipment Minimum Duct ~ Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 SPtback Master Suite 'vi Split Air Conditioner 12 OqFFR Ducts in Attic Split Air Conditioner 12.0 SEER Ducts in Attic Split Air Conditioner 12.0 SEER Ducts in Attic 42 4.2 4.2 Setback I g Area Setback Guest Bedrooms Setback Guest Suite WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in: Input Cap. or Recovery Standbyy Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss ( 0) R -Value AMERICAN CG62-75T75 Large Gas Recirc/Time+Temp 1_ 75,100 75 0.79 0.0244 0.0 AMERICAN DVG62-50T42-N Small Gas Recirc/Time+Temp 1 42.000 50 0.57 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS UUIVIrLIANUC J 1 A I CIVICIV l This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Wgg 7q ¢n Name: Gina Rose Title/Firm: The Woodard Group Title/Firm: G.R. Rose CAD Design Address: 80-880 Vista Bonita Trail Address: 42335 Washington Suite F #330 La Quinta, CA 92253 Palm Desert, CA 92211 Telephone: 760-775-7088 Telephone: (760) 345-4859 LIC. IF: (signature) (date) Enforceme cy Name: Title/Firm: Address: Telephone: (si" e) (date) signature/stamp) IEnergyPro 3.1 By EnergySoft • User Number: 5862 Job Number: Page:6 of 46 ,y 4 Certificate of Compliance: Residential (Addendum) CF -1 R Project Title 7/28/2005 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The HVAC System "Master Suite" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Master Suite" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 155 sqft Masonry Veneer Exterior Mass, 6.00" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 288 sqft Masonry Veneer Exterior Mass, 6.00" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 105 sqft Masonry Veneer Exterior Mass, 6.00" thick at Zone 1 HIGH MASS Design(see C-213) - Verify Thermal Mass: 323 sqft Exposed Slab Floor, 4.00" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 788 sqft Covered Slab Floor, 4.00" thick at Zone 1 The HVAC System "Living Area" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "Living Area" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2343 sqft Exposed Slab Floor, 4.00" thick at Zone 2 The HVAC System "Guest Bedrooms" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Guest Bedrooms" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 165 sqft Masonry Veneer Exterior Mass, 6.00" thick at Zone 3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS rovider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "Master Suite" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Master Suite" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Living Area" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Living Area" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Guest Bedrooms" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. - The HVAC System "Guest Bedrooms" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Guest Suite" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide erification of the TXV, or measure the Refrigerant Charge and Airflow. EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:7 of 46 4 Certificate of Compliance: Residential (Addendum) CF -1 R 11"I'arker Residence 7/28/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. ' I Plan I Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 84 sqft Masonry Veneer Exterior Mass, 6.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 228 sqft Masonry Veneer Exterior Mass, 6.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 271 sqft Masonry Veneer Exterior Mass, 6.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 405 sqft Exposed Slab Floor, 4.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 225 sqft Covered Slab Floor, 4.00" thick at Zone 3 The DHW System "AMERICAN DVG62-50T42-N" Energy Factor = 0.570. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "Guest Suite" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Guest Suite" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: '183 sqft Masonry Veneer Exterior Mass, 6.00" thick at Zone 4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 362 sqft Exposed Slab Floor, 4.00" thick at Zone 4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 224 sqft Covered Slab Floor, 4.00" thick at Zone 4 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS •d Th HERS t t document th fId verification d diagnostic testing f thesef CF 6R rove er. a rater mus ocumen e, ie ven ica ion an iagnos is es mg o measures on a form Run Initiation Time: 07/28/05 13:55:53 Run Code: 1122584153 _nergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:8 of 46 Plan Field ThHVAC St"Gt Sit e ysem uesue" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. r • • Mandatory Measures'Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (`) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures `§150(.): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ❑X not apply to exterior mass walls). `§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. § 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no . . greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls , 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. , §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §1 50(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. t 1. Masonry and factory -built fireplaces have: r a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. IAI §150(i): Setback thermostat on all applicable heating and/or cooling systems. FXJ §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater.' 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12_external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:9 of 46 f Mandatory Measures Checklist: .Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an 0 asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT - Space Conditioning, Water Heating and Plumbing System Measures: (continued) X] I150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of -the ducts. , -' . , , . . 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive' duct tapes unless such a tape is used in combination with mastic and drawbands: 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. « 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. X❑ § 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no r continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria. ' Lighting Measures ❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ❑ §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. Computer Method Summa Part 1 of 3) C -2R RP-_ar_ke.r_Residence 1.,111. 7_/_28/_20-0-5 Project Title _Lot_241 Ih.e_H.id.e.awa_y La_Q.u.i.nta _0..24_ Date Project Address _0._0.5.9_ Building Permit # _G_R-.ose CAD_Des.ig.n (760) 345-4859 1.5.5_ Documentation Author Telephone Plan Check/Date Co 15 -0-059 Field Check/Date .p_uter_Re.cform.ance Compliance Method (Package or Computer) Climate Zone 1.05 Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin _0_028_ Space Heating 3.95 2.60 1.35 Space Cooling 36.37 34.50 1.86 Domestic Hot Water 6.10 7.66 -1.56 Totals 46.42 44.76 1.65 Percent better than Standard: 3.6% BUILDING COMPLIES Total Conditioned Floor Area: 4,670 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Type: Single Fam Detached Building Front Orientation: (Northwest) 315 deg Total Fenestration Area: 32.0% Number of Dwelling Units: 1.00 Total Conditioned Volume: 45,558 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 4,670 ft 2 BUILDING ZONE INFORMATION Zone Name 4iaster-Suite ving_Area G.ue.st_B.edroorns G_uest_Su.ite OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Floor Area Volume .Roof 1.,111. -0-02.8- 00 _0..24_ Wall- 1.96. _0._0.5.9_ 45_ 90_ Wall_ 1.5.5_ _0._0.59. 135_ 9.0_ Wall_ 28.8_ -0-059 _225. 90 Wall_ 1.05 0.059 -3-1-5--90 _Roof _2„3.4.3_ _0_028_ 0_ -0--0- 0_Wall- Wall 33.0 -0-059- 45 90_ Wall_2.47 -0-05.9- 135 -90- 0Wall_ Wall 3.0.3_ _0._0.59_ -225_ -9.0- 90_Wall- Wall 404 _0._0.59_ _31.5. -9.0- -Door 26 -0-38.7- 9.1.5 90 .Roof 63.0 -0,028- 0 0 Wall- 1.6.5_ -0...0.5.9_ 45. 9.0_ Wall -8.4. -0059 t3.5_ 9.0 Wall_ 228_ _0.0.59 225_ 9.0_ Wall_ 27_1. _0_0.59_ -31.5_ 90_ _Roof 5.8.6. _0..028_ 0_ 0_ Wall_ 11.6_ -0_.0.59_ ---A.5_ 90_ Wall- 88_ 0059 1.35 90 Wall- 1.8.3 -0-059 _31.5 90_ 1.,111 2,.3_4.3 6.30. 586 Solar Gains Y/N 1.0,554 _23,4.3.0 6.,.300 _5,274 # of Units Zone Type _0..24_ Steeping -0.5.0_ Living _0..13_ S.leeping 01.3_ Sleeping Form 3 Reference .R_38-Roof_(.R38 2x1_4 16.) R2LW_ _all_(W.21.2x6.16.) .R2LWall_(_W_ __.2_L2x6 1.6.) R2.1_Wall_(W_,2L2x6 16.) R3.8Roof_( 8.3.8..2x14.1.6.) .R2_LWall_(_W 21_.2x6-16) R2_LWall_(W 21.2x616) R2.1_Wall_(_W_ _.212x6..16.) R2.1_WalL(W_ __212x6_16.) Solid_W_ood_Door -R=.38-Roof-(R-.-3-8-2x-1-4.J-6.)- R-21 R_38-Roof-(R..38 2x1_4.16.)R21 Wall (w_,21.2x6�6) .R2J-Wall_(W.212x6..1.6.) .Rt2.1_Wall_(W.212x6 t6.) .R2.1_Wall_(W_ __212x616) .R_3.8_Roof_(R.38.2x1_4.16.) .R2_LWal I_(.W.212x6..1.6.) .&2.1_W a l l_(W .212x616.) 7 -one -1 Zone1 Zone 1 Zone 1 ,Zone -1 .Zone- Zone- Thermostat Vent Type Hgt. Area _SleepingStaL -2 _nLa _Living.S.tat_ 2 _nLa _S.leeping.S.tat_ 2 _nLa -Sleeping-Stat- 2 _n/.a Location / Comments EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 11 of 46 1 Computer Method Summary (Part 2 of 3) C -2R Y arker Residence 7/28/2005 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments I- Wiad.ow Left_(N.ortheast) _51._0_ -0...640_ 0.53_ 4.5_ _9.0. Glazing -Zone-1 2 Window Rear Southeast) 51.0 0.640 0.53 135 90 Glazing Zone 1 3 Window Rear (Southeast) 21.0 0.450 0.52 135 90 Glazing Zone 1 4 Window Rear (Southeast) 30.0 0.550 0.48 135 90 Glazing Zone 1 5 Window Right (Southwest) 8.8 0.450 0.52 225 90 Glazing Zone 1 6 Window Right (Southwest) 12.5 0.550 0.48 225 90 Glaiinq Zone 1 7 Win w i hS_(Sosshwgst)1Q.,Q 0.450 0.-52 225 90 GLazin Zone 1 8 Window Right (Southwest) 33.0 0.450 0.52 225 90 Glazing Zone 1 5 W_in_dow Le1t_(fQrthe3-St) 15.0 0_55Q 0.48_ 45 90 riazina Zone 2 0 WLadow Left -(Northeast) 10.5 0 45Q 052 45 90 Glazing Zone 2 u Window Left (Northeast) 15.0 0.550 0.48 45 90 Glazing Zone 2 12 Window Left (Northeast) 100.0 0.470 0.48 45 90 Glaiinq Zone 2 1.3 Window_Rear(Sou.theast) _2.1-0- 0._4.50 0.52. 1.35_ 90 Glazing Zone -2 14 Window Rear Southeast) 165.0 0.470 0.48 135 90 Glaiinq Zone 2 15 Window Rear Southeast) 136.6 0.470 0.48 135 90 Glazing Zone 2 16 Window Right (Southwest) 93.5 0.450 0.52 225 90 Glazing Zone 2 17 Window Right (Southwest) 93.5 0.450 0.52 225 90 Glazing Zone 2 18 Window Front Northwest) 42.5 0.640 0.53 315 90 Glazing Zone 2 >0 Window Front_(NQdb-wQst) --2-9-8- 045Q 252 ---3j-5- 90 GLazi Zone 2 20 Window Front (Northwest) 68.0 0.470 0.48 315 90 Glaiinq Zone 2 21 Window Front (Northwest) 29.8 0.450 0.52 315 90 Glazing Zone 2 22. Window LeftNortheast) 25.0 0.550 0.48 45 90 Glazin Zone 3 23 Window Rear Southeast) 10.0 0.550 0.48 135 90 Glazing Zone 3 24 Window Rear Southeast) 25.5 0.640 0.53 135 90 Glaiinq Zone 3 25 Window Right (Southwest) 25.5 0.640 0.53 225 90 Glazing Zone 3 6 Window Right (Southwest) 25.5 0.640 0.53 225 90 Glazing Zone 3 7 Window Right (Southwest) 10.5 0.450 0.52 225 90 Glazing Zone 3 28 Window Right (Southwest) 15.0 0.550 0.48 225 90 Glazing Zone 3 29 Window Right (Southwest) 10.5 0.450 0.52 225 90 Glazing Zone 3 INTERIOR AND EXTERIOR SHADING window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 8.5 6.0 10.0 0.1 10.0 10.0 2 Bug Screen 0.76 8.5 6.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 3.5 6.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 _ 8.5 6.0 10.0 0.1 10.0 10.0 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 10.0 10.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 14 Bug Screen 0.76 10.0' 16.5 2.0 0.1 2.0 2.0 0.1 4.0 0 0.0 0.0 0 15 Bug Screen 0.76 10.0 13.8 10.0 0.1 10.0 10.0 16 Bug Screen 0.76 8.5 11.0 2.0 0.1 2.0 2.0 17 Bug Screen 0.76 8.5 11.0 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 8.5 5.0 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 8.5 3.5 2.0 0.1 2.0 2.0 0.0 0.0 0 0.1 4.0 0 20 Bug Screen 0.76 8.5 8.0 2.0 0.1 2.0 2.0 0.0 0.0 0 0.1 4.0 0 21 Bug Screen 0.76 8.5 3.5 2.0 0.1 2.0 2.0 22 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 23 Bug Screen 0.76 5.0 2.0 10.0 0.1 10.0 10.0 24 Bug Screen 0.76 8.5 3.0 10.0 0.1 10.0 10.0 25 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 3.5 3.0 2.0 0.1 2.0 2.0 28 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 29 Bug Screen 0.76 3.5 3.0 2.0 0.1 2.0 2.0 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 12 of 46 1 muter Method Summary (Part 2 of 3) C -2R Warker Residence 7/28/2005 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments _30. Window_Right_(.S_outh..west) 1-5._0_ _0_550_ _0..48_ _225_ _9.0. Glazing _Zo.ne_3 31 Window Front Northwest) 5.1 0.450 0.52 315 90 Glazing Zone 3 32 Window Front Northwest) 63.8 0.640 0.53 315 90 Glazin Zone 3 33 Window Left Northeast) 10.0 0.450 0.52 45 90 Glazing Zone 4 34 Window Left Northeast) 10.0 0.450 0.52 45 90 Glazing Zone 4 35 Window Left (Northeast) 13.5 0.450 0.52 45 90 Glazing Zone 4 35 Window Left (N0beast) 15.0_ Q550 0.A8 45 9Q Glazing --oma 4 37 Window Left Northeast) 25.5 0.640 0.53 45 90 Glazing Zone 4 3$ Win w Le_ft_(Llor�east) 21.0 _Q 45Q -0-5-Z 45_ 60Glazin Zone 4 39 Vin -d -ow Le -ft _(No_rtheast) 32.0 -0-55D- ----OA8- 45 90 Glazin - o0-4- s4AO AO Window Rear (Southeast) 12.8 0.450 0.52 135 90 Glazing Zone 4 41 Window Rear (Southeast) 25.5 0.640 0.53 135 90 Glazing Zone 4 4.2 Window Er_ont_(North..we-st) 600 0.450- 0.52. _315_ _90 Glazing _Zon.e_4 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 31 Bug Screen 0.76 32 Bug Screen 0.76 - 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 4.5 -30 2.0 -0-1 2.0 2.0 36 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 0.1 4.0 0 0.0 0.0 0 37 Bug Screen 0.76 8.5 3.0 0.1 4.0 0 0.0 0.0 0 38 Bug Screen 0.76 8.5 2.5 2.0 0.1 2.0 2.0 39 Bug Screen 0.76 5.0 -6.5 2.0 0.1 2.0 2.0 40 Bug Screen 0.76 8.5 16.0 2.0 0.1 2.0 2.0 41 Bug Screen 0.76 8.5 3.0 2.0 0.1 2.0 2.0 42 Bug Screen 0.768.5 7.0 2.0 0.1 2.0 2.0 0.0 0.0 0 0.1 4.0 0 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Paae:13 of 46 1 Computer Method Summary (Part 3 of 3) C -2R Project Title 7/28/2005 Date THERMAL MASS FOR HIGH MASS DESIGN F2 insulation Type Length Area Thick. Heat Sib Pe_ri_m_eter 24 Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Ma oLryVse .r X55. _6_0.0 _25. _0..62 R=2.1_WalL(W.2_L2x6.16.) 0_ Zone 1-LEcterio.r_Mass Masonry. Veneer 288 6_00 25 0_62 R-21 Wall (W.21.2x6.16) 0 Zone 1 / Exterior Mass MasoLry Veneer 105 5600 _25 -0_6_2 R-21 Wall (W_ 21 2KU66) Efficiency and Location Duct Thermostat ZQaer 1Le_ri_oLMass Concrete. Heavyweight 323 4_00 28 0_98 n/a 0 Zone 1 / Slab on Grade Concrete,_Heeaxywe.ight 788 4.00 28 -0-9-8 n/a 2 Zone1 / Sla_b_on Gide PERIMETER LOSSES 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. F2 insulation Type Length Factor R -Val. Depth Location / Comments Sib Pe_ri_m_eter 24 —76 --0-0 0 Zone 1 Slab Perimeter _7]_ 01-6. _0.0. _0 Zane -1 alab-Be_rimeter 213 0.76 0-0 _Q Zone 2 Slab-Berimeter 68 -0,7-6 —0-0 0 Zona -1 .Slab -Perimeter 30 -Q_76 —0-0 0 Zont=3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments CentFreace 80° AFU—E QtZE in ttic 4.2 Setback MasteLaLdte Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Living Area Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Guest Bedrooms �entraI Furnace 80% AFUE Ducts in Attic 4.2 Setback Guest Suite Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Air Condsi_2er 12.0SEER p)icJsin Attic 4.2 wetback Mes_teLaurte Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Living Area Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Guest Bedrooms Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Guest Suite WATER HEATING SYSTEMS Ratedl Tank Energy Factl 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gam EfficiencyLoss (%) Ext. AMERICAN CG62-75T75 .Large Gas Be irc/Time±Zemp 1 75.100 75 0.79--- —0-0244____ 0.0 AMERICAN DVG62-50T42-N Small Gas RecircfT'ime+Temp 1 42,000 50 0.57 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Comouter Method Summary r (Part 3 of 3) C -2R Parker Residence 7/28/2005 Project Title " + _ Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments �,oncjde,Heavyweight _2,.34.3. _4._0.0 _28. 0_98- n1a 0- Zone-21—Slab—on—Grade ' Masonry Veneer 165 6_00 25 0_62 R-21 Wall (W.21 2x6.16) 0 Zone 3 /Exterior Mass .MssoM Vene-e 84 6-00 25 0.622 R-21 W la_I (W.21.2-4-!zC) 0 ZonQ 3Exte1L4LMass Masonry Veneer 228 6_00 25 0_62 R-21 Wall (W.21.24.16) 0 Zone 3 / Exterior Mass .Mason. ry_Menee.r 271 6-00 25 0-62 R-2-1 Wall (K21.2x6J-Q) 0 Zone_3 / ExteaoL -M a -ss PERIMETER LOSSES F2 Insulation ' Type Length Factor R -Val. Depth Location / Comments Slab ri me ter 58 0:76. 0-Q 8 Zone 4 Slab Perimeter 10 0.1-6. 0.0 —0 Zone_4 HVAC SYSTEMS , Heating Equipment Minimum Distribution Type ' Type (furnace, heat Efficiency and Location. Duct Thermostat j Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc:) R -Value • Type Comments Hydronic Piping Pipe , Pipe Insul. System Name Length Diameter Thick. ` Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS Ratedl, Tank+ Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution kin Input Cap. or Recovery Standby R -Value System Name Type Type Syst.Btu/hr (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Comouter Method Summary (Part 3 of 3) C -2R Warker Residence 7/28/2005 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) _ Cap. Cond. Form -3 Reference R -Val. Comments Cote. Heavvyweight 4.0.5. _4...0.0 _28.. 0...9-8- n1a 0. Zone_31_S.1ab_onGrade Concrete, Heavyweight 225 4.00' 28 0_98 n/a 2 Zone 3 / Slab on Grade asom Ve—ne-e --18 -6-0-0 25 X62 R_2J W—a 1 L (K. 21.2x6.16) Exterior Mass Concrete, Heavyweight 362 4_00 28 0_98 n/a 0 Zone 4 / Slab on Grade Con-cr-e-te.,-He-a-vyweigh.t4-00 ?8 -0-9-8 n/� 2 Zo�4LSlab_on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val., Depth Location / Comments HVAC SYSTEMS 4 ' Heating Equipment Minimum Distribution Type Type (furnace, heat ' Efficiency and Location Duct '� Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Hydronic Piping Pipe _ Pipe Insul. System Name Length Diameter Thick.- hick:Cooling CoolingEquipment Minimum Duct Type (air conditioner, Efficiency Location -Duct Thermostat Location / heat pump, evap. cooling). (SEER) (attic, etc) R -Value Type Comments WATER HEATING SYSTEMS > , Rated' Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. Btu/hr (g Aa Efficiency Loss (%) Ext. For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 07/28/05 13:55:53 Run Code: 1122584153 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 16 of 46 a 4 Computer Method Summary (Addendum) C -2R Project Title 7/28/2005 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan I Field The HVAC System "Master Suite" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Master Suite" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 155 sqft Masonry Veneer Exterior Mass, 6.00" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 288 sqft Masonry Veneer Exterior Mass, 6.00" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 105 sqft Masonry Veneer Exterior Mass, 6.00" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 323 sqft Exposed Slab Floor, 4.00" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 788 sqft Covered Slab Floor, 4.00" thick at Zone 1 The HVAC System "Living Area" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "Living Area" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2343 sqft Exposed Slab Floor, 4.00" thick at Zone 2 The HVAC System "Guest Bedrooms" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Guest Bedrooms" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 165 sqft Masonry Veneer Exterior Mass, 6.00" thick at Zone 3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS Irovider. i ne Mtits rater must document the field ventication and diagnostic testing of these measures on a torm GF -15K. Plan Field The HVAC System "Master Suite" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Master Suite" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Living Area" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Living Area" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Guest Bedrooms" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Guest Bedrooms" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Guest Suite" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide erification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 07/28/05 13:55:53 Run Code: 1122584153 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 17 of 46 K 4 Computer Method Summa (Addendum) C -2R Parker Residence 7/28/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 84 sqft Masonry Veneer Exterior Mass, 6.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 228 sqft Masonry Veneer Exterior Mass, 6.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 271 sqft Masonry Veneer Exterior Mass, 6.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 405 sqft Exposed Slab Floor, 4.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 225 sqft Covered Slab Floor, 4.00" thick at Zone 3 The DHW System "AMERICAN DVG62-50T42-N" Energy Factor = 0.570. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "Guest Suite" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Guest Suite" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 183 sqft Masonry Veneer Exterior Mass, 6.00" thick at Zone 4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 362 sqft Exposed Slab Floor, 4.00" thick at Zone 4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 224 sqft Covered Slab Floor, 4.00" thick at Zone 4 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS d Throve er. HERS rater must document thefield verif'cat'on and diagnostic tes t'mg of these measures on a form CF 6R EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Pagel8 of 46 Plan Field he HVAC System "Guest Suite" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. . i EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Pagel8 of 46 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY WROJECT NAME DATE Parker Residence 7/28/2005 SYSTEM NAME FLOOR AREA Master Suite 1,111 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I I CFM I Sensible 1,256 22,722 514 464 17,279 0 1,136 864 0 0 0 0 0 0 0 0 0 1,136 864 24 995 514 19 007 3 Ton Unit 26,141 3,301 36,000 Total Adjusted System Output 26,141 3,301 36,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.3 OF 69.3 OF 105.0 OF O Supply Air Ducts Outside Air 0 cfm 104.3 °F Supply Fan Heating Coil 1200 cfm ROOMS 69.3 OF 70.0 °F 115.0 / 73.5 OF Outside Air 0 cfm / 60.7 OF h Return Air Ducts `i ETRICS (Airstream T 72.9 / 60.7 OF 72.9 / 60.8 OF 55.0 / 53.8 OF Supply Fan 1200 cfm Cooling Coil �% Return Air Ducts 4 Supply Air Ducts 55.9 154.2 OF 51.3% R.H. ROOMS 72.0 / 60.4 OF EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 19 of 46 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY 0ROJECT NAME DATE Parker Residence 7/28/2005 SYSTEM NAME FLOOR AREA Living Area 2,343 Number of Systems 2 Heating System Output per System 48,000 Total Output (Btuh) 96,000 Output (Btuh/sqft) 41.0 Cooling System Output per System 48,000 Total Output (Btuh) 96,000 Total Output (Tons) 8.0 Total Output (Btuh/sqft) 41.0 Total Output (sgft/Ton) 292.9 Air System CFM per System 1,600 Airflow (cfm) ' 3,200 Airflow (cfm/sgft) 1.37 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM ISensiblel Latent I CFM Sensible 3,463 62,654 1,084 1,140 42,463 0 3,133 2,123 0 0 0 0 0 0 0 0 0 3,133 2,123 68 919 1 084 46 710 4 Ton Units 69,969 8,483 96,000 Total Adjusted System Output 69,969 8,x83 96,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.4 OF 69.4 OF 105.0 OF O Supply Air Ducts Outside Air - 0 cfm 104.4 °F Supply Fan Heating Coil 3200 cfm ROOMS 69.4 OF 70.0 °F K Return Air Ducts 4 (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) 15.0 / 73.5 OF Outside Air 0 cfm 9/60.7 °F 72.9 / 60.7 OF 72.9 / 60.7 °F. 55.0 / 53.8 OF Supply Fan Cooling Coil 3200 cfm Return Air Ducts Supply Air Ducts 55.9/54.1OF 51.1% R.H. ROOMS 72.0 / 60.3 OF EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Paae:20 of 46 1 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY �ROJECT NAME DATE Parker Residence 7/28/2005 SYSTEM NAME FLOOR AREA Guest Bedrooms 630 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I I CFM I Sensible 1,080 19,534 29 419 15,595 0 977 780 0 0 0 0 0 0 0 0 0 977 780 21 488 29 3 Ton Unit 26,210 3,156 Total Adjusted System Output 26,210 3,156 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm 36,000 36,000 Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.4 of 69.4 of 105.0 of Supply Air Ducts Outside Air 0 cfm 104.4 of Supply Fan Heating Coil 1200 cfm ROOMS 69.4 of 70.0 of Return Air Ducts 1E I 1000LING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) 15.0/73.5OF 72.8/60.5OF 72.8/60.6OF . 55.0/53.7OF Outside Air 0 cfm 8 / 60.5 of Supply Fan Cooling Coil 1200 cfm Return Air Ducts Supply Air Ducts 55.8/54.1OF 50.9% R.H. ROOMS 72.0 / 60.3 of EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Pane: 21 of 46 1 VAC SYSTEM HEATING AND COOLING LOADS SUMMARY wROJECT NAME DATE Parker Residence 7/28/2005 SYSTEM NAME FLOOR AREA Guest Suite 586 ENGINEERING CHECKS SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I I CFM I Sensible 976 17,654 2A, 320 11,922 0 883 596 0 0 0 0 0 0 0 0 Supply Fan Heating Coil 0 883 596 19,4191 27 13 114 3 Ton Unit 26,172 3,177 26.0 of 69.5 OF 69.5 of 105.0 OF Total Adjusted System Output 26,172 (Adjusted for Peak Design Conditions) 3,177 36,000 36,000 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.5 OF 69.5 of 105.0 OF Supply Air Ducts Outside Air O4 0 cfm Supply Fan Heating Coil 104.5 of 1200 cfm ROOMS 69.5 of 70.0 of Return Air Ducts COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 115.0 / 73.5 of 72.7 / 60.5 of 72.7 / 60.6 of 55.0 / 53.7 of Supply Air Ducts Outside Air 0 0 cfm Supply Fan Cooling Coil 55.7 / 54.0 OF 1200 cfm 50.8% R.H. ROOMS '72.7 / 60.5 of 72.0 / 60.3 of Return Air Ducts EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Pane: 22 of 46 f L. ROOM LOAD SUMMARY ROJECT NAME DATE Parker Residence 7/28/2005 SYSTEM NAME FLOOR AREA Master Suite 1,111 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 1 Zone 1 1 1,256 22,722 514 1,256 22,722 514 464 17,279 ' s f ` PAGE TOTAL 1 1,256 22,722 514 TOTAL 1 •1,256 22,722 51411— 464 17,279 464 17,279 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:23 of 46 4 ROOM LOAD SUMMARY ROJECT NAME DATE Parker Residence 7/28/2005 SYSTEM NAME FLOOR AREA Livinci Area 2,343 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 2 Zone 2 1 3,463 62,654 1,084 3,463 62,654 1,084 1,140 42,463 ' PAGE TOTAL 1 3,463 62,654 1,084 1,140 42,463 TOTAL 1 3,463 62,654 1,084 1,140 42,463 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:24 of 46 4 4 ROOM LOAD SUMMARY ROJECT NAME DATE Parker Residence 7/28/2005 SYSTEM NAME FLOOR AREA Guest Bedrooms 630 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM I SENSIBLE Zone 3 Zone 3 1 1,080 19,534 291 1,080 19,534 291 419 15,595 IL ' PAGE TOTAL 1 1,080 19,534-291 TOTAL 1 1,080 19,534 291 419 15,595 419 15,595 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:25 of 46 ROOM LOAD SUMMARY �ROJECT NAME Parker Residence DATE 7/28/2005 SYSTEM NAME Guest Suite FLOOR AREA 586 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 4 Zone 4 1 976 17,654 271 976 17,654 271 320 11 922 r ` PAGE TOTAL : 976 17,654 271 320 11,922 t . TOTAL 1 976 17,654 271 320 11,922 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:26 of 46 ROOM HEATING PEAK LOADS Project Title Date IParkPr RPsidPnr.P 7/28/2005 Room Information Desi n Conditions Room Name zone 1 Time of Peak Jan 12 am Floor Area 1,111 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Btu/hr Conduction Area X X x X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x X x U -Value X X x X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x X x x AT of = = = = = = = = = = = = = = = = = = = = = = _ = = = = = = = = = = = = = = Btu/hr 1,111.0 0.0284 44.0 1,386 743.7 0.0592 44.0 1,937 102.0 0.6400 44.0 2 872 72.8 0.4500 44.0 1,441 42.5 0.5500 44.0 1,028 perimeter= 101.0 44.5 4,494 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 13,160 Infiltration: C 1.001 X 1.064 X 1= 1=11, x 9.50 X 0.50 / 60] X ® =4,119 Schedule Air Sensible Area Ceiling Height ACH 1W Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 17 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:27 of 46 ROOM HEATING PEAK LOADS Project Title Date IParki-r RPsiriPnra 7/28/2005 Room Information Desi - n Conditions Room Name zone 2 Time of Peak Jan 12 am Floor Area 2,343 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Btu/hr Conduction Area X X X X X X X X X X x X X X X X X X X X X X X x X x X X X X X X x x X X X x X U -Value X X X X X X X X X X x X X X X X X X X X X X X X X X X X X X X X X x x X X X X QT OF = = = = = = = = = = = = = = = = _ = Btu/hr 2343.0 0.0284 44.0 2 923 1,284.4 0.0592 44.0 3.346 30.0 0.5500 44.0 726 278.0 0.4500 44.0 5,504 469.6 0.4700 44.0 9.711 25.5 0.3872 44.0 434 42.5 0.6400 44.0 1,197 perimeter = 213.0 44.5 9,478 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 33 321 Infiltration: r 1.001 X 1.064 X 2 343 X 10.00 x 6] X 44 = 9 143 `schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 42 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:28 of 46 ROOM HEATING PEAK LOADS roject Title Date Parker RPcidPnr.P 7/?R/?f1n5 Room Information Desicin Conditions Room Name zone 3 Time of Peak Jan 12 am Floor Area 630 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Btu/hr Conduction Area X X X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x U -Value X X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x AT of = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr 630.0 0.0284 44.0 786 748.7 0.0592 44.0 1,950 65.0 0.5500 44.0 1,573 140.2 0.6400 44.0 3,949 26.1 0.4500 44.0 517 perimeter = 98.0 44.5 4,361 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 13 137 Infiltration: L 1.001 x 1.064 x 630 x 10.00 x 6] x 44 = 2 458 Schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:29 of 46 1 ROOM HEATING PEAK LOADS Project Title Date Parker Resirience 7/28/2005 Room Information Desicin Conditions Room Name Zone Time of Peak Jan 12 am Floor Area 586 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Btu/hr Conduction Area X X X X X x X x XX x X X X x X X X X X x X X X x X X x X X X X X X X X X X X X U -Value X X X X X x X X x x X X x X X X X X x x X X X x X X x X X X X X X X X X X X AT of = = = = = = = = = = = = = = = = = Btu/hr 586.0 0.0284 44.0 731 386.5 0.0592 44.0 1,007 127.2 0.4500 44.0 2 520 47.3 0.5500 44.0 1,144 51.0 0.6400 44.0 1,436 = 68.0 44.5 3,026 _perimeter Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 9 864 Infiltration: r 1.00 X 1.064 x 586 X 9.00 X 0.50 / 60] X 44 = 2 058 schedule Air Sensible Area Ceiling Height ACH LT Fraction TOTAL HOURLY HEAT LOSS EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:30 of 46 IE RESIDENTIAL ROOM COOLING LOAD SUMMARY • Parker Residence 7/28/2005 Project Title Date Room Name Zone 1 Design Indoor Dry Bulb Temperature: 720F Design Outdoor Dry Bulb Temperature: 1160F Design Temperature Difference: 440F • Conduction 2x14.1 Area U -Value 1 1.111.01 X DETD1 X 61.0 X 40.6 X 44.0 X 44.0 X 44.0 X X X X Btu/hr 1,921 1 788 2.872 1,441 1 028 1. Design Equivalent Temperature Difference (DETD) Page Total 9 051 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 7 _(Northeast) 1. Southeast G18 _(Southeast) G18A (Southeast) G17 (Southwest) G17A (Southwest) G16 (Southwest) G14 (Southwest) 1,350 ( 18.6 ( 0.0 X X X X X x X x x X 15 + + + + + + + + + + 51.0 X X x X x X X X x x 48) X ) x X X x X x x )x )X 0.590 = = = = = = = = = = 1,444 ( 18.6 1 32.4 62 0.590 1,350 ( 18.6 15 2.4 62) 0.579 248 ( 18.6 15 11.4 62) 0.534 527 ( 0.0 15 8.8 62) 0.579 316 ( 0.0 15 12.5 62) 0.534 414 ( 0.0 15 10.0 62) 0.579 359 ( 33.0 15 0.0 62) 0.579 287 ( ( Sched. Page Total 4 944 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,111 x 0.500 Watts/sqft x 3.413 Btuh/Watt = 1,896 Occupants 1.00 x 1,11 X 245 Btuh/OCC. /333 sgft/occ. = 817 Receptacle 1.00 x 1,11 x 0.500 Watts/sgft x 3.413 Btuh/Watt = 1,896 Process 1.00 x 1,111 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: 00 x .Q6 x 1 111 x 9_50 x Q.50 / 60] = 4.,]19 chedule Air Sensible Area Ceiling Height ACH 4"\T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22 722 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 1,111 x 155 Btuh/OCC. / 333 sgft/occ. = 517 Receptacle 1.00 x 1 111 x 0.000 Watts/sqft X 3.413 Btuh/Watt = 0 Process 1.00 x 1 111 x 0.000 Watts/sgft x 3.413 Btuh/Waft = 0 Infiltration: 1.00 X 4=77 X 1 11 X 9.50 x 0.50 / 60] 0.00001 = 1 chedule Air Latent Area Ceiling Height ACH UW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 514 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number:. Page:31 of 46 RESIDENTIAL ROOM COOLING LOAD SUMMARY • Parker Residence 7/28/2005 Project Title Date FJ • Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Zone 2 720F 116°F 44°F Conduction Area U -Value DETD 1 Btu/hr X X X X X X X x X X X X X X X X 61.0 = = = = = = = 4,052 40.6 3 088 44.0 726 44.0 5,504 44.0 9,711 40.6 401 44.0 1.197 X X 1. Design Equivalent Temperature Difference (DETD) Page Total 24 679 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr G24 _(Northeast) G23 (Northeast) ' G23A 48 G20 _(Northeast) (Northeast) G22 (Southeast) G21 (Southeast) G19 (Southeast G1 (Southwest) G2 (Southwest) 6 Northwest ( 0.0 x X X x x x X X x x 15 + 15 + 15 + 15 + 15 + 15 + 15 + 15 + 15 + 15 + 15.0 X x X X X X x x X x 48 ) X x X X X X X X 0.534 = = = = = = = = = = 385 ( 0.0 10.5 48) 0.579 292 ( 0.0 15.0 48) 0.534 385 ( 0.0 100.0 48) 0.534 2,565 ( 0.0 21.0 62) 0.579 754 ( 51.2 113.8 62) 0.534 4,182 ( 136.6 0.0 62) 0.534 1,095 ( 34.1 59.4 62) 0.579 2,428 ( 34.1 59.4 62), 0.579 2,428 ( 0.0 42.5 48)x 0.590 1,204 Sched. , Page Total 15 716 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 2,343 x 0.500 Watts/sgft x 3.413 Btuh/Watt = 3,998 Occupants 1.00 X 2,343 X 245 Btuh/OCC. / 333 sgft/OCc. = 1 722 Receptacle 1.00 x 2,343 x 0.500 Watts/sqft x 3.413 Btuh/Watt - 3,998 Process 1.00 x 2,343 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration:pp x 06 x E=2 ,3 -A-31 x0 QO x 50 / 60] = 9,43 Schedule . Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 62,6541 Sched. Latent Gain Frac. Area Heat Gain. Btu/hr Occupants 1.00 X2,343 X 155 Btuh/OCC. / 333 sgft/ocC. = 1,089 Receptacle 1.00 x 2 343 x 0.000 Watts/sqft x 3.41 Btuh/Waft = 0 Process 1.00 x 2,343 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: 1 1.00 X 4,771' X 2 343 X 10.00 x 0.50 / 60] 0.00001 = Schedule Alr Latent Area Ceiling Height ACH �yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,084 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: ' Page: 32 of 46 n • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Parker Residence 7/28/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Zone 2 720F 116°F 440E Conduction Area U -Value DETD 1 Btu/hr 1. Design Equivalent Temperature Difference (DETD)-. Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area - SGF Area SGF SC Btu/hr G3 _(Northwest) ( 0.0 x 15 + 29.8 X 48) X 0.579 = 827 G.5 (Northwest) ( 0.0 x 15 + 68.0 X 48) x 0.534 = 1,744 G4 (Northwest) ( 0.0 x 15 + 29.8 x 48)x 0.579 = 827 ( x + X )X = ( x + X )X = ( x + x )x = ( x + X )X = ( x + X )X = ( x + x )x = Sched. Page Total [:::::3:397 Internal Gain Frac. Area - Heat Gain Btu/hr Lights 1.00 X 2,343 x 0.500 Watts/Sgft x 3.413 Btuh/Watt = 3,998 Occupants 1.00 X 2 343 x 245 Btuh/occ. / 333 sgft/OCc. = 1.722 Receptacle 1.00 x 2,343 x 0.500 Watts/sqft x 3.413 Btuh/Watt — 3,998 Process 1.00 x 2,343 x 0.000 Watts/sqft x 3.411 Btuh/Waft = 0 Infiltration:1 QO x 06 x E:72,_3_ x Q QO x 0 50 / 60] = E:L9,_1A31 Schedule Air Sensible Area - Ceiling Height ACH �INT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 62,6541 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X LE�2 ,343 x 155 Btuh/OCC. / 333 sgft/occ. = 1 089 Receptacle 1.00 x ,343 x 0.000 Watts/sqft X 3.41 Btuh/Waft=Process 1.00 x 343 x 0.000 Watts/Sgft X 3.413 BtUh[Waft = 0 Infiltration: [ 1.00 x 4,77 x 2 343 x 10.00 x 0.50 / 60] 0.00001 = 0 Schedule Air Latent Area Ceiling Height ACH Dyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,084 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:33 of 46 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Parker Residence 7/28/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Zone 3 720F 1160F 440E Conduction Area U -Value DETD' Btu/hr x _(Northeast) 61.0 = 1,090 x 9A 40.6 = 1800 x (Southwest) 44.0 = 1,573 x G13A 44.0 = 3,949 x 0.590 44.0 = 517 x x x x 1. Design Equivalent Temperature Difference (DETD) Page Total 8,928 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr G9 _(Northeast) Gg (Southeast) 8 (Southeast) 9A (Southwest) 9B (Southwest) G12 (Southwest) G12A (Southwest) G13 (Southwest) G13A (Southwest) G11 Northwest ( 0.0 x x X x x X X X x X 15 + + + + + + + + 25.0 X X X x X X X X X x 48) X x X X x X x X x x 0.534 = = = = = = = = = = 641 ( 10.0 1 0.0 62) 0.534 80 ( 25.5 15 0.0 62) 0.590 226 ( 0.0 15 25.5 62) 0.590 933 ( 0.0 1 25.5 62) 0.590 933 ( 9.3 15 1.2 62) 0.579 124 ( 9.3 151+ 5.7 62) 0.534 263 ( 9.3 15 1.2 62) 0.579 124 ( 9.3 15 5.7 62) 0.534 263 ( 0.0 151+ 75,1 48) 0.579 142 Sched. Page Total3 729 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 630 x 0.500 Watts/sqft x 3.413 Btuh/Watt = 1,075 Occupants 1.00 x 630 x 245 Btuh/occ. / 333 sgft/occ. = 463 Receptacle 1.00 x 630 x 0.500 Watts/sqft x 3.413 Btuh/Watt = 1,075 Process �1.0�0 x 630 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: C 0o x I 1.0691 x660 x0 QO x0 50 / 60] 1_4� = 2,458 Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19,534 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occu antsL=000000 x 630 x 155 Btuh/OCC. / 333 sgft/occ. = 293 Receptacle x 630 x 0.000 Wafts/sgft x 3.413 Btuh/Watt = 0 Process x 630 x 0.000 Watts/sgft X 1 3.413 Btuh/Watt = 0 Infiltration: 1 1.00 X 4 77 :2S X 63 x 10.00 x 60] 01 = 0 Schedule Air Latent Area Ceiling Height ACH �Wyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 291 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 34 of 46 0 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Parker Residence 7/28/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Zone 3 720F 116°F 440E Conduction Area U -Value DETD 1 Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 17 _(Northwest) ( 0.0 X 15 + 63.8 X —48)X 0.590 = 11805 ( X + X )X = ( X + X )X = ( x + X )X ( x + X )X ( X + X )X ( x + X )X = ( x + X )x = x x P� ( X I ix )X Sched. . Page Total 1,805 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 630 X 0.500 Watts/sgft x 3.413 Btuh/Watt = 1,075 Occupants 1.00 X 630 X 245 Btuh/OCC. / 333 sqft/occ. = 463 Receptacle 1.00 x 630 X 0.500 Watts/sqft x 3.413 Btuh/Watt = 1,075 Process 1.00 x 630 x 0.000 Watts/sgft x 3.4133�Btu h/Watt = 0 Infiltration: C 00 x 06 x 630 x o_0o x 0 50 / 60] �4_4J = 2,458 Schedule Air Sensible Area Ceiling Height ACH nsT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19 534 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 630 x 155 Btuh/occ. / 333 sqft/occ.= 293 Receptacle 1.00 X 630 x 0.000 Watts/sqft X 3.413 Btu h/Watt = 0 Process 1.00 x 630 X 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: [ 1.00 x 4 77 x 63 x 10:00 x 0.50 / 60] 1 -0.00001 = 0 Schedule Air Latent Area Ceiling Height ACH DW Fraction TOTALHOURLY LATENT HEAT GAIN FOR ROOM 291 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 35 of 46 RESIDENTIAL ROOM COOLING LOAD SUMMARY • Parker Residence 7/28/2005 Project Title Date Room Name Zone 4 Design Indoor Dry Bulb Temperature: 7200F Design Outdoor Dry Bulb Temperature: 116 F Design Temperature Difference: 440F Conduction Area U -Value DETD 1 Btu/hr 40 X _(Northeast) 61.0 = 1,013 X G31A 40.6 = 929 X (Northeast) 44.0 = 2,520 X 14 44.0 = 1,144 X 15.0 44.0 = 1,436 1. Design Equivalent Temperature Difference (DETD) Page Total 7 043 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr G28 _(Northeast) G2g Northeast) G31 (Northeast) G31A _(Northeast) 15 (Northeast) G26 (Northeast) G25 (Northeast) G27 (Southeast)_ 14 (Southeast) G30 (Northwest) ( 0.0 X x x x X X x X x x 15 + 15 + 15 + 15 + 15 + 15 + 15 + 1 + 1 + -15+ 10.0 X X x X X X X X X x 48 ) X )x )x X X X X x x 0.579 = = = = = = = = = = 278 ( 0.0 10.0 48 0.579 278 ( 0.0 13.5 48 0.579 375 ( 0.0 15.0 48)x 0.534 385 ( 0.0 25.5 48) 0.590 722 ( 0.0 21.0 48) 0.579 584 ( 0.0 32.3 48) 0.534 828 ( 4.7 8.1 62) 0.579 331 ( 9.3 16.2 62) 0.590 675 ( 0.0 60.0 48) 0.579 1567 Sched. Page Total 6,123 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 586 x 0.500 Watts/sgft x 3.41 Btuh/Watt - 1,000 Occupants 1.00 X 586 X 245 Btuh/OCC. / 333 sgft/occ. = 431 Receptacle 1.00 x 586 x 0.500 Watts/sqft X 3.413 Btuh/Watt = 1,000 Process 1.00 x 586 x 0.000 Watts/sgft x 3.413 Btuh[Watt = 0 Infiltration: C 1 QO 06-4 x El x 58 x 9 QO x o_50 / 60] = 2,Q58 Schedule Air Sensible Area Ceiling Height ACH z2,T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17654 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 586 x 155 Btuh/OCC. / 333 sgft/occ.= 272 Receptacle 1.00 X 586 x 0.000 Watts/sqft X 3.41 Btuh/Watt = 0 Process 1.00 x 586 x 0.000 Watts/sgft X 3.41 Btuh/Watt = 0 Infiltration: 1 .001 X 4 it it Area X 58 x 9.00 x 60] -0.00001 = Schedule Air LateCeiling Height ACH Dyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 271 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:36 of 46 1 Sladden engineering 8792 Stanton Ave.; Suke A. Binns Pa*. CA 90421 (714) 623.0852 Fax (T1 4) 5 7.3805 38-725 oarend Ln., galea 0, Palm Q4s4R CA 12211 (760)172-3593 Fax (160) project No. 544°2199 May 21, 2003 d3 05'9Y2 hir: John Garulira N'D Le Qui nta Paxtttexe 51-100 Avonue.53 LA Quints, Califdrnia 92253 Project; Lot 190 Via Vitwerae Trod 29894-2 The Hideaway La Qunnta• California Subject: Geotechnical Update Ret 1 Report' of Testing "d Observation Dv016 Rough (Trading prepared by- Barth Systems Southwest (ESS) dated August 28, 2002; File No, 07117.11, Report Nd. 01-07.718. prepared by Eattb. Systems Southwest dated '2. Geotech�cal Eng'hebring Report April 11, 2001; File Na 0811901. _ hty ate to AR requested, we bane reviewed t the above resider= The project ce s locstedtOn loot o the design and eonstructzon of the Cub Tract 29894-2 along Vta Vin�nze within Hideaway �� Club development i><z the City of La Quints, California. It is our understanding orad by pton�tdi nal �haIlowevread rolativel,Y lightweight Wood' $came structure Aupp footings and 6onerete slabs ea'gradv. ceded during the rough greding of the R'de°way prQ co 6i The subject lot was previously gr with the - The rough" grading included ovMxmvauon of the native turfing voile alas$ paacement of engineered fall material too eruct the aubjed building pad and adjacent lots' The site grading i* w1MmQnzed in the refere=d Report of Testing and 01bAervatian ping Rough Gra,dieg along with the compaction teat result*, The referenasd reports dude recoramendatione pertaining to the construction of rQgidtn'ha structure foundations- Based upon our review of the refeteneed reports, it is our opixLion thatt the structural valued jAcluded in the referenced grading report remain applicable for the prapored residential structure foundations. design and construction of the mviava] rovgl, graded, the rtme&aj gTNding required 0Lt this time Because tho lot has been p Y riiouid be ffiiniyats;. 'd'lb2 bu;la*^"Fa sold be cleared of surface vegetat'on, scarified and c-tOO go moietu" wnditioned prion w precise gradin¢. The exposed apron fLU pldaeemCmpaAny fill that a minimum of 90 �rcent relative mmpact'oll is attained prior to fill p materia] should be placed in thin lifts at near optimutm uloiatt intent pnd compacted to at least 90 percent relative camp action. S31 8 . 33 2 project No, $44-2199 May 21, 2003 g3•o5.32,2 t1UoWable Big preee s: T)aB allowable bearing pressures recbrnmended in th(I should referenced grading report remaLn applicable. Convedtional-shallow spread footsnge be bottomed into properly campacted fill material s minimum o'f It inches below loevest adjacent grade. Continuous footings-should be at least 12 inches wide and iwlaw Pad hould .footiAgs should be ;at le"i 2 feet wide. Continuous footings and Isolated pad footing tivc be designed utilising allowable bearing pressures of 150 psf and 2000 30p9f0 sf forr each Allowable increases of 300 psf for each additional 1 foot of width end llo p additional 6 inchrg of depth may be utilized if desired. The maximum allowable bearing pressure should be 9000 ptf, The recommended allowable fbundatio,n paring pressures may be increased by one-third when contid4ring wind and eeiemlc loading. The bearing soils are rion,expansive and fall within the "ve#y low" expansion category *0wrdence with Unilbsm BirildiftB Code (USG) classification criteria. Patdxent 1997 UBC Seitimic Design parameters are summarized on the attacbed data sheet. If you have qi1eationa regarding this letter or the referenced reports. pleAAe contact thg undereigii�d. . Respectfully submitttd, GLADDEN ENC}IN=RIN(1 _ PaOFE Brett L. Andeia a' prin#al.Engineer SER/pc L p-t4LWa Copies: 41ND TA Quints P J Sladden eygineerieg r x 33 May 21, 2009 8 Project No. 644-2199 g _ 03.06.922 1897 uNlroRM iounmNa CODE ENPORMATION The International Cotu'ie.rence of Building O6icials 1997 Uniform Building Code conca1n8 • substantial revisions and -additions to the eatthq'uake engineering section in Chapter 16. Concepts contained in the code that will likely be. relevant to' construction of the Proposed structur6a are summarized below. Ground ehaking is ezpect6d to be the primary hszard most likcly to aStct the site, based upon ptoximicy to eignifQctnt faults capable of geberatitil large earthquakes: Mxga or fault zones considered to be moat hkcly to create strong ground shaking at•the site are lusted below. Fault Zone Appr=i=te Dietant5a Fr*m $its Fault TYPg ` 1997 i.JBO San Andreae 9.8 km A San Jacinth 28 km A - Based on our field obaervatione and understanding of local geologic conditions, the eail`pmfile type judgod applicable to tbie site is 80, generally deecribed as stiff or dente soil. The site is located within UBC. Seismic -Zone 4. The fcUewing table presents additional �oovftcienta and factors relevant to oeiemie mitigation for new eorietruction gpou adoption of the 1997 code. Nt�arBoutce Neu-8ouxoe seismic seismic Seismic A,ocelerstion Velocity - Coefaqieat Coefficient 99urco , Factor Na Factor, N. G C, ' Sats Andreae 1.01 1.22 F 0.44 N. 0.64 Nr San Jacinto 1 _ 1.0 1 s -1.0 1 0,44, N,