13-0563 (SFD)P.O. BOX 1504 VOICE(760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT ISPECTIONS (760) 777-7153 BUILDING PERMIT Date: 2/10/14 Application Number: 13-00000563 Owner: Property Address: 53452 VIA PALACIO CLARK & SOLIS DEV. APN: 772-560-059- - - 52940 AVENIDA MONTEZUMA Application description: DWELLING - SINGLE FAMILY DETACHED LA QUINTA, CA 92253 �� �) �� • i Property Zoning: LOW DENSITY RESIDENTIAL (760) 564-3511 Application valuation: 494537 CITY OF IAQU§1TA FIRWE DEPT. Contractor: Applicant: Architect or Engineer: CLARK JR, JACK L. 48476 STILLWATER DRIVE LA QUINTA, CA 92253 (760)564-3511 Lic. No.: OOR SQUARE FOOT Lic. No.: 506667 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Bu sin and Professionals Code, and my License is in full force and effect. Li�ceennssee Class: B gni No.: 506667 2 Date: — •� Contractor: '+' /. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&PrC. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY 1 hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXOPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I sh become subject to the workers' compensation provisions of Section 3700 of the r de, all forthwith_,porripjr, with those provisions. Date:i� � % Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to b ' 9en construction, and hereby authorize representatives of this cgunty to/eJennttteer upon above-mentioned p erty f reinspection p /�� / Datle%/ - Signature IAPPlicant or Agent): u /�C C w r LQPERMIT Application Number . . . . . 13-00000563 Permit . . . BUILDING 2013 Additional desc . . Permit Fee . . . . 738.63 Plan Check Fee 00 Issue Date . . . . Valuation . . . . 494537 Expiration Date 8/09/14 Qty Unit Charge Per Extension BASE FEE 573.43 295.00 -------=------------------------------------------------------------------=- .5600 THOU BLDG $200,001-$1M 165.20 Permit . . . ELECTRICAL 2013 Additional desc . . Permit Fee . . . . 226.65 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 8/09/14 Qty Unit Charge Per Extension 1.00 23.8300 LS ELEC FIXTURES, FIRST 20 23.83 1.00 23.8300 EA ELEC SERVICES 23.83 1.00 23.8300 EA ELEC TEMP POWER POLES 23.83 1.00 143.0000 LS ELEC NEW RES, FIRST 1 KSF 143.00 1.00 --------------------------------------------------------------------------- 12.1600 EA ELEC NEW RES, ADD'L 1 KSF 12.16 Permit . . . MECHANICAL 2013 Additional desc . Permit Fee . . . . 476.70 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 8/09/14 Qty Unit Charge Per Extension 5.00 35.7500 EA MECH FURNACE 178.75 5.00 35.7500 EA MECH CONDENSER/COMP 178.75 9.00 11.9200 EA MECH VENT FAN 107.28 1.00 ---------------------------------------------------------------------------- 11.9200 EA MECH EXHAUST HOOD 11.92 Permit . . . PLUMBING 2013 Additional desc . . Permit Fee . . . . 405.27 Issue Date . . . . Expiration Date . . 8/09/14 Plan Check Fee . . Valuation . . . . Qty Unit Charge Per 27.00 11.9200 EA PLBG FIXTURE/TRAP 1.00 11.9200 EA PLBG BUILDING SEWER Extension 321.84 11.92 Application Number . . 13-00000563 Permit . . . . . . PLUMBING 2013 Qty Unit Charge Per Extension 2.00 11.9200 EA PLBG WATER HEATER/VENT 23.84 1.00 11.9200 LS PLBG GAS SYS, 1-4 OUTLETS 11.92 1.00 35.7500 LS PLBG GAS SYS, 5+ OUTLETS 35.75 --------7------------------------------------------------------------------- Special Notes' and Comments NEW SFD WITH FIRE SPRINKLERS THIS PERMIT DOES NOT INCLUDE POOL SPA, BLOCK WALLS , OR DRIVEWAY APPROACH.CONST PER 2010 CALIF BUILDING CODES. November 25, 2013 10:41:24 ---------------------------------------------------------------------------- AM JJOHNSON. Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 736.09 BLDG STDS ADMIN (SB1473) 20.00 DIF COMMUNITY CENTERS -RES 129.00 DIF CIVIC CENTER - RES 942.00 DIF FIRE PROTECTION -RES 433.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 344.00 PLAN CHECK, ELECTRICAL 104.63 DIF PARK MAINT FAC - RES 40.00 PLAN CHECK, MECHANICAL 286.00 PLAN CHECK, SFD GRADING 143.00 PLAN CHECK, PLUMBING 395.72 DIF PARKS/REC - RES 2048.00 BLDG PC 200K -1M 1844.15 STRONG MOTION (SMI) - RES 49.44 TUMF: RESIDENTIAL 1837.44 DIF STREET MAINT FAC -RES 116.00 DIF TRANSPORTATION - RES 2842.00 Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total LQPERMIT Charged Paid 1847.25 .00 .00 .00 12310.47 .00 14157.72 .00 Credited Due .00 1847.25 .00 .00 .00 12310.47 .00 14157.72 I Building �� V Address Tittf / 4 4 " P.O. BOX 1504 78-495 CALLE TAMPICO T v1 LA QUINTA, CALIFORNIA 92253 Mailing Address 5-9— 4O M�U�M�3NsP C "0Will n p Address WWI , \ n m� City / (IM l� Zlp 422 NO- Y64- 35 State Lic. City & Classif. Lic. # D si ner ,4:�Tq 5 PAW?_Mp Citv Zip 2ZS State G Lic. # � LICENSED CONTRACTOR'S DECLARATION Ihereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contrac- tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). O1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: Ty A.P. Number P Legal Description _ Project Description l a — S4�3 APPLICATION ONLY /OCC. 0^V 2 _ X235 Sq. Ft. No. Size Stories New Add ❑ Alter ❑ ,4 YC7_/0o,-2, 0 Estimated Valuation 1 w v f � ' 4 No. Dw. C Units 1 Repair ❑ Demolition ❑ y o/ PERMIT AMOUNT Plan Chk. Dep. 1Z Alow,� Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL .� CONTACT INFORMATION NAME: PHONE: ZONE: BY: Minimum Setback Distances: Front Setback from Center Line — Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Validated by: — Validation: YELLOW = APPLICANT Date Permit PINK = FINANCE Cdachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVELONEAMOUNT: LEVEL Two AMOUNT: MITIGATION AMOUNT: COMMIIND. AMOUNT: DATE: RECEIPT:. ,. CHECK#: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Clark _&_ Solis Dev_elopment (Residence_ @The Hideaway)' Date: January 21, 2014 Owner's Name: Phone No. Project Address: 53-452 Via Palacio, La Quinta, CA 92253 Project Description: Single Family Dwelling Unit APN: 777-220-021 Tract #: Lot #'s: 5,560 Sq. Ft. Type of Development: Residential XX Commercial Industrial Total Square Feet of Building Area: Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: - 1 Signature: I�GLf G C�(L SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code Project Agreement Existing Not Subject to Fee 65995 Approval Prior to 1/1/87 Requirement 5,560 $3.20 $17,792.00 Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Leticia Torres, Facilities Analyst NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires thk-thislbistrict provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. M V:c/tnydoes'de%,fecs/ceilificate olcompliance loan updated 3-2007 112010 r Rc'( CO:' rNG•REQUFSTF.T)11Y.- VIltNWLALITT LANT)'11'1'f.F, (:OMPANY AlWW-N RECORDED, MAIL ID: Clark & olis Development, T.T.0 78015 M in Street La Quint,. CA 92253 11G iV. ..VV1 /VVJ DOC # 2008-0021927 01/15/2008 08:000 Fee:13.00 Page l of 3 Doe T Tax Paid Recorded in Official Records County of Riverside Larry U..Uard Qsaossor, County Clark 4 Recorder IIIIII IIIIIII IIII IIII IIIIII IIII IIIIIII III III IIII IIII S R U PAGE SIZE DA MISC LONG RFD COPY M A L 4115 426 O NCOR SMF NCHO ��ExAM U -( Tf4W T:20 I T I UNI J ASSESSOR'S PAROL NO.: 777-220.021-6 The tuldcrsipltcd Grantors) declare that tic I)OC 1MCNT TRANSFER TALC LS: X 49 TTTLF MWER NO.: 2139015. • S 605.00 Cmiuty FSCROVf 'NO.: 25596-B-003 XX computed an the full value of the interest of prtgwrty conveyed, or computed on the full value lass Il>1'..'value of liens or encwnbtaraxe mmuining (hLrcon at the time of We. OR ui=fcr'is 1::XEW1 from tax for the following rcasun: FORA V ,L1ATi1.•F CONSIT)F1tA'1TON, receipt of which is htruby ai xowledged, Paul Anthony Monuilbauo and Cynthia Anne Mcvtalb o, •Trustees of Elle Molludbano Family Trust dated October 11, 1984 beretry GRANTS) to Clark &Solis Development, LLL: , A Li mi f,Cd li,aabi'I i ty Company all drat real, property situated in the City of'La Quints, County of Kiverside, State cif CA, described as: "Courple, Legal Description' on Exhibit'A' attached hereto and made apart bercof" I)wcd 1)e�ember 12, 200? Mate of C 'rlifi�m is } County of S Gam,. 41(-41flem } On be,4--L i S',?•yv7 ,13cforeolef ti imr N•Y4tJ4 ie2 Nolary'?ublic Personally appuwvd -P -f4 h sir N{C.h ¢aL�En�j" "10 1'C7edtr i�t:t (or pruvided Eo me. ou the basis of satisfactory evidence to be the persons) whcnc: nanic:(s) is/are subscribed to the within in4trumcnt and acknowledged to me Hutt he/she/they exuuted the same in er/their authorized capa:ity(ies), and that by him/their nignutcs) on the instrument:the pem nt(s) or the cmtity apex% behalf of which ill person(c) acted, executed the im-&umrut. WII NI•iS B my hand and official sea MAIL TAX STATEMENTS TO: Clark & Solis Devclopmtuit, LLC 79015 Main Street La Quanta, CA 9.253 PaulAlthuny aao, Thu;tcc is Anne Moutalbano, Trtrctcc: +0L/ 611 144@r'o.rkyu,ta,tc.5 TNH MEq A, SHEHADEN COit L 017402" 21 IMF�wero • e�uraarb► co.. uo►.. rr. rot l (This area for official notary se,11) RZIVV r.UVj jUUj EXHIBIT "A" All that certain real property situated in the County of Riverside, State of California, described as follows: Lot 235 of Amended Tract No. 29894-2, in the City of La Quinta, County of Riverside, State. of California, as per Map recorded In Book 327 Pages 56 through 88, inclusive -of Maps, in the Office of the County Recorder of said 'County. rb;6�r subst&rices -lying below the surface of said land, but with no right of surface entry, as provided in deeds of record. Vla FeLl ac I fQ September 23, 2013 Clark & Solis Development, LLC 52940 Avenida Montezuma La Quinta CA 92253 RE: Lot 235 at 53452 Via Palacio Final Construction Documents #3 Dear Mr. Clark and Mr. Solis, The Hideaway Design Review Committee (DRC) reviewed the revised Final Working Drawings for your home on Via Palacio at the September 17, 2013 meeting. The project was approved and construction may begin at the lot once a Building Permit has been obtained. The following comments can be addressed during construction. 1. It does not appear the chimney cap overhang will work in the field (as proposed). Please submit any changes necessary to accommodate the design during ,construction, but prior to installation in the field. 2. The committee could not locate a change or note provided in the plan set regarding the following comment: Specifications and cut sheets were provided for the wall mounted light fixtures; however, the cut sheets indicate 3 — 60 watt bulbs (or 180 watts total per fixture) which is in excess of the lighting allowances described in the guidelines. Please contact Brook Marshall at DRCFacilitator@gmail.com or by phone at 760-219-8057 with any questions or to schedule your Pre -Construction Meeting once a permit has been obtained. As a reminder, Hideaway DRC approvals are valid for one year. Sincerely, Hideaway Design Review Committee cc: R. Ricciardi at Jed.dsgn@gmail.com gmail.com lqjlclark@yahoo.com DRC File CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 9/25/2009 Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date: / 30/ Developer: JACL4 Tract No.: Tract Name: Y"&ILot No.(s): Address(s): 5 �' 2 \ r, 'rG! I&L—/D Phone Number: (.)l&0) The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the Building & Safety Department: ❑ CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4, #5 & #7 BELOW ❑ TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW ❑ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1, #2, #3, #5 & #7 BELOW ❑ WALLS, SIGNS, OTHER: PROVIDE ITEM #6 BELOW 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation Certificate can be provided. 2. Attach geotechnical certification. of grading plan compliance including compaction reports from a licensed Soils Engineer. Recently rough graded residential developments which have a previously approved geotechnical certification are exempt from this requirement. 3. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots. 4. Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 certification number is required. 5. Attach a copy of the rough or precise grading plan to the Public Works Department showing building location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain development plan. 6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. 7. Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW approved building construction projects require either a WQMP or a completed WQMP exemption form. Approved maps/plans may be viewed at the following link: http://www.la-guinta.org/PlanCheck/m search.aspx I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently conplete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff. K r— k... C I V C Recommended by: Date: �-- / /0 / 11 Pudic Works Distribution:JAN 3 0 2014 ( ) Green Sheet to Building & Safety ( ) Green Sheet to Planning Department CITY OF LA QUINTA Declined for approval for reason(s) as follow(s), please correct and resubmit: MMU ITY DEVELOPM NT I or D City of La Quinta - PM10 Fugitive Dust Control Project Information Construction Phase PM10 Agreement <1 acre/lot or Infill Project) Project Information Project Contractor: T:\Checklists - Forms & ADDllcationsWorms & Aoolications\GREEN SHEET cover & PM10 Less than 1 Acre Revised 10-02-12.doc . Project Phase The Project Name: u/et (check one) Project Tract/Lot Numbers: _ _1c1� C Construction C� Demolition Project Street Address: Ali* / �1l4z_e� � ���-. - Total Acres in Active Cons. -ruction (<1 acre per Lot): Anticipated Start Date: / �� / Anticipated Completion Date: /h5'c7/ � PM10 Contact Please note: Dust control is required 24 hours a day, 7 days a week, regardless of Information construction status. Person listed below is responsible for dust control during business and non -business hours. Name:41 / Title: / Lp Company Name: A,�%O r �`C (%' �► Mailing Address: ©. .60 ! ��b City, State, ZIP Code: II Primary Phone M �C �/ �r 3� Fax M 24 Hour Emergency Phone#: Cell Phone M /70 Email Address: ' O PM10 Certificate #: -3 ley 19 —e —13,24- The above stated property owner (or authorized represent'ative): ❖ Shall act as his/her acknowledgement of. dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; ❖ Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. ❖ Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; ❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; ❖ Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes; ❖ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control plan y City/County initiated abatement activities. CAWS I'?�o-1� Sign ure oflDroperty Owner or Authorized Representative Date City of La Quinta - PM10 Fugitive Dust Control Plan (<1 acre per Lot or Infill Project) T-iis Fugitive Dust Control Plan shall take into account applicable SCAQMD Regulations Rule 403, 403.1, 401, 402, 201, 2D3 and Portable Equipment Registration Program (PERP). ❖ WATERING: Continuous watering is required to prevent dust and must occur a minimum of four (4) times daily. Water shall be applied from an adequate sized metered water source to dry soils to prevent: ■ Visible dust emissions >20% opacity ■ Visible dust emissions that travel >100 feet from the source (within site) Pian Submittal Job Site Owners Number, Street, or PO City, State, Postal C Owners Phone Nun Owners E -Mail Add Building Permit Number. Project Description: SFR Exempt: ❑ (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Project Managers Name Project Managers Phone Number Project Managers E-mail Address Builder / Contra Number, Street or PO City, State, Postal C Project Square City Approval By Date of City Approval To Be Discarded: Product Trash Asphalt Brick/Block Cardboard Commingled Concrete Drywall Donated / Reuse' 1/30/2014 53452 Via Palacio Clark & Solis Development, LLC 48476 Stiliwarter Drive La Quinta, CA 92253 760-625-3368 l9il_cl_ark®vahoo.com Jack Clark 760-625-3368 loilclark®vahoo.com Clark & Solis Development, LLC 48476 Stillwarter Drive La Quinta, CA 92253 5,500 Tons 10.45 Not recyclable 0.00 Recyclable 0.00 Recyclable 1 0.321 Product Masonry (broken) Plaster Scrap Metal Tile (floor) Tile (roof) Wood Landscape Debris Tons Recyclable Recyclable 'Describe Items I Totals: Recycle Trash Projected Diversion: 18.411 10.5 1 1 763_.7_-_/_.1 1 I understand it is the property owners responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued In the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer station. e'r / Developer / Project Manag r / Superintendent Date V BUILDING ENERGY ANALYSIS REPORT PROJECT: CLARK & SOLIS DEVELOPMENT LLC LOT 235 VIA PALACIO La Quinta, Ca 92253 Project Designer: J.E.D. DESIGNS. MAY 012013 45175 PANORAMA DRIVE, SUITE O CyOF `�/3 PALM DESERT, CA 92260 MM�IVny lj,,V (760) 485-3119 74 �topM6vr Report Prepared by: Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, Ca 92247 760.485.8927 RECEIVED Job Number: MAY 0=1 2013 Ig043013 CIiY OF LA. Q.UINTA - �� �� COMMUNITY DEVELOPMENT Date:-�1rv9G SAF ................� 4/30/2013 F0p0t�� DEPT, N'S�'n' ._ The EnergyPro computer program has been used to perform the calculations sum arized`in-t.' a re rt. This program has pproval and is authorized by the California Energy Commission for use with both the Residential and,Nosr sidentt 2 8 � 'I ing Energy Efficienc Standards. This program developed by EnergySoft, LLC —www.energysoft.co EnergyPro 5.1 by Ener Soft User Number: 5732 RunCode: 2013-04-30704:29:57 ID: 1043 I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary ® )tj SA r--& �EpA T. CONS UN Dr CTIp T� I 1 2 3 11 14 EnergyPro 5.1 by EnergySoft Job Number: ID: Ig043013 " �'a — 0Y User Number: 57321 1 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name CLARK & SOLIS DEVELOPMENT LLC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1413012013 Date Project Address LOT 235 VIA PALACIO La Quinta California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 5,527 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. EI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Slab Unheated Slab -on -Grade None 4,468 Perim = 0' New Wall Wood Framed R-21 3,379 New Wall Wood Framed R-21 1,432 New Demising Wood Framed w/o Crawl Space R-30 1,389 New Roof Wood Framed Attic R-38 4,365 Radiant Barrier New Door Opaque Door None 23 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Right (S) 42.6 0.330 0.26 none none Bug Screen New Right (S) 34.0 0.320 0.31 none none Bug Screen New Right (S) 24.0 0.330 0.26 none 12.0/0.0 Bug Screen New Rear (E) 123.0 0.330 0.21 none none Bug Screen New Left (N) 87.0 0.340 0.25 none none Bug Screen New Front (W) 48.0 0.330 0.26 6.0 none Bug Screen New Front (M 50.0 0.340 0.25 none none Bug Screen New Right (S) 11.0 0.340 0.25 none none Bug Screen New Rear (E) 68.8 0.320 0.27 none none Bug Screen New Left (N) 5.0 0.320 0.27 none none Bug Screen New Front (W) 48.0 0.330 0.26 10.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC System - Zone 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC System - Zone 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC System -Zone 3 Ducted Ducted Attic,)Cei in Qns�v,9nte 8.0 New WATER HEATING BU^��LA Ot . Type Gallons Min. Eff Distr b�ion� �U/NT Status 2 Large Gas 74 0.78 l All pes Ins p p &P -r New COT �� `JIO i - Ener Pro 5.1 by Ener Soft User Number: 5732 RunCode: 2013-04-30T04:M57 1t4043Q_13 13 Pa e 3 of 17 x PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Proi,ect Name CLARK & SOLIS DEVELOPMENT LLC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1413012013 Date Project Address LOT 235 VIA PALACIO La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,527 Addition n/a # of stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Rear (E) 240.0 0.440 0.24 14.0 9.8/4.5 Bug Screen New Rear (E) 73.0 0.320 0.31 14.0 none Bug Screen New Front (lM 176.0 0.440 0.24 none none Bug Screen New Front (IM 36.0 0.320 0.27 none none Bug Screen New Front (IM 54.0 0.330 0.26 5.5 none Bug Screen New Front (lM 80.0 0.440 0.24 5.3 5.5/5.5 Bug Screen New Front (KJ 24.0 0.320 0.27 5.3 none Bug Screen New Right (S) 48.0 0.330 0.26 10.0 none Bug Screen New Rear (E) 48.0 0.330 0.26 none none Bug Screen New Front (IM 49.0 0.320 0.31 none none Bug Screen New Rear (E) 14.0 0.340 0.25 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC System - Zone 4 Ducted Ducted Attic, Cge'iling Ins, vennteedd� 8.0 New dne' l f rrr P n . WATER HEATING 'moi U & ��P 1 rA Ot . Type Gallons Min. Eff Distributro'n ,'S�' D Itatus nA- 7- EnergyPro 5.1 by Ener Soft User Number. 5732 RunCode: 2013-04-30704:29:57 ID: 1 0 Page 4 of 17 IN PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name CLARK & SOLIS DEVELOPMENT LLC Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/30/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System A O Smith Water Products FPSH-75 is a non-NAECA large storage gas water heater. Verify DHW details. HIGH MASS Design -Verify Thermal Mass: 1,034.0 ft2 Covered Slab Floor, 4.000" thick at Bedrooms HIGH MASS Design - Verify Thermal Mass: 963.0 ftz Exposed Slab Floor, 4.000" thick at Bedrooms HIGH MASS Design - Verify Thermal Mass: 1,169.0 ft2 Exposed Slab Floor, 4.000" thick at Living, Dining, Bar HIGH MASS Design - Verify Thermal Mass: 199.0 ft2 Covered Slab Floor, 4.000" thick at Fam-Kit-Off-Laundry-Casita HIGH MASS Design -Verify Thermal Mass: 1,103.0 ft' Covered Slab Floor, 4.000" thick at Fam-Kit-Off-Laundry-Casita The Roof R-38 Roof Attic w/Radiant Barrier includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System YorkCZB60.PS8CN100.2000cfm includes credit for a 11.2 EER Condenser. A certified HERS rater must field verify the J nstallation of the correct Condenser. The HVAC System HVAC System - Zone 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC System - Zone 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System YorkCZB24. PS8A 12N40.800cfm includes credit for a 11.3 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC System - Zone 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC System - Zone 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System YorkCZB42.PS8C20N100.1400cfm includes credit for a 11.4 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC System - Zone 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC System - Zone 3 incorporates HERS verified Duct Leakage'. HERS -field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System York.CZB60.PS8CN100.2000cfm includes credit for a 11.2 EE Condenser.'A1'eertified ER {�t�pr —u el rify the installation of the correct Condenser. , � 0ILC IN'G , c `�' + 1 1 T The HVAC System HVAC System - Zone 4 incorporates HERS Verified Refrigerrit Chargelor,a�C�ha, a India'at 4Di pl EPl n The HVAC System HVAC System - Zone 4 incorporates HERS verified Duct Leakage. C�f'S i J>y( ntifi�a ori j�'ndidtagag 'stic testin • is required to verify that duct leakage meets the specified criteria. i h1 v C TION DATE Ener Pro 5.1 by Ener Soft User Number: 5732 RunCode: 2013-04-30704:29757--, 0: 1 X430 Page 5 of 17 s v PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date CLARK & SOLIS DEVELOPMENT LLC ❑ Multi Family ❑ Existing+ Addition/Alteration 4/30/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 4.40 5.12 -0.72 Space Cooling 54.39 52.39 2.00 Fans 10.87 13.77 -2.90 Domestic Hot Water 6.21 4.17 2.04 Pumps 0.00 0.00 0.00 Totals 75.87 75.44 0.43 Percent Better Than Standard: 0.6% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (W 270 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (w) 2,010 565 Fuel Available at Site: Natural Gas (N) 982 92 Raised Floor Area: 459 (E) 1,529 567 Slab on Grade Area: 4,468 (S) 1,697 160 Average Ceiling Height: 10.3 Roof 4,365 0 Fenestration Average U -Factor: 0.37 TOTAL: 1,383 Average SHGC: 0.25 Fenestration/CFA Ratio: 25.0% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author p Company Santiago Lopez-Ocampo V P.O. Box 1018 4/30/2013 Address Name City/State/ZipCity/State/Zip La Quinta, Ca 92247 Phone 760.485.8927 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, a d recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installatio qua�a- uilding envelope sealing require installer testing and certification and field verification by an approv d HEMS rete , 13U/LD/A1(3 Designer or Owner (per Business & Professions Cod .) & SAF Qt.IfNTq Company J.E.D. DESIGNS. Aiq��' E%Y D EPT Ro Address 45175 PANORAMA DRIVE, SUITE A" Name JOSE ENR QUE DA'Q�C City/State/Zip PALM DESERT, CA 92260 Phone (760) 485-Signe uc-r/0 .icense Date T �Y Ener Pro 5.1 by Ener Soft User Number 5732 RunCode: 2013-04-30704:29:57 04 Page 6 of 17 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name CLARK & SOLIS DEVELOPMENT LLC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/30/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 1,034 0.730 None 0 180 New 4.4.7-A1 Zone 1 - Bedrooms Slab 963 0.730 None 0 180 New 4.4.7-A1 Zone 1 - Bedrooms Wall 643 0.069 R-21 180 90 New 4.3.1-A6 Zone 1 - Bedrooms Wall 222 0.069 R-21 90 90 New 4.3.1-A6 Zone 1 - Bedrooms Wall 3971 0.069,R-21 0 90 New 4.3.1-A6 Zone 1 - Bedrooms Wall 283 0.069 R-21 270 90 New 4.3.1-A6 Zone 1 - Bedrooms Demising 465 0.034 R-30 0 90 New 4.4.2-A7 Zone 1 - Bedrooms (faces Roof 1,321 0.025 R-38 0 0 New 4.2.1-A21 Zone 1 - Bedrooms Demising 465 0.034 R-30 0 90 New 4.4.2-A7 Zone 2 - Bedroom 2nd Flo Wall 238 0.069 R-21 180 90 New 4.3.1-A6 Zone 2 - Bedroom 2nd Flo Wall 121 0.069 R-21 90 90 New 4.3.1-A6 Zone 2 - Bedroom 2nd Flo Wall 225 0.069 R-21 0 90 New 4.3.1-A6 Zone 2 - Bedroom 2nd Flo Wall 159 0.069 R-21 270 90 New 4.3.1-A6 Zone 2 - Bedroom 2nd Flo Roof 573 0.025 R-38 0 0 New 4.2.1-A21 Zone 2 - Bedroom 2nd Flo Slab 1,169 0.730 None 0 180 New 4.4.7-A1 Zone 3 - Living, Dinin , B Wall 107 0.069 R-21 180 90 New 14.3.1-A6 JZone 3 - Living, Dinin� FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGCz Azm Status Glazing Type Location/Comments 1 Window 18.6 0.330 NFRC 0.26 NFRC 180 New Sierra Pacific Windows - Fr Dr. L Zone 1 - Bedrooms 2 Window 34.0 0.320 NFRC 0.31 NFRC 180 New Sierra Pacific Windows - Cas .L Zone 1 - Bedrooms 3 Window 24.0 0.330 NFRC 0.26 NFRC 180 New Sierra Pacific Windows - Fr Dr. L Zone 1 - Bedrooms 4 Window 123.0 0.330 NFRC 0.21 NFRC 90 New Sierra Pacific Windows - SGD.L Zone 1 - Bedrooms 5 Window 15.0 0.340 NFRC 0.25 NFRC 0 New Sierra Pacific Windows - DH .Lo Zone 1 - Bedrooms 6 Window 15.0 0.340 NFRC 0.25 NFRC 0 New Sierra Pacific Windows - DH.Lo Zone 1 - Bedrooms 7 Window 15.0 0.340 NFRC 0.25 NFRC 0 New Sierra Pacific Windows - DH .Lo Zone 1 - Bedrooms 8 Window 15.0 0.340 NFRC 0.25 NFRC 0 New Sierra Pacific Windows - DH .Lo Zone 1 - Bedrooms 9 Window 48.0 0.330 NFRC 0.26 NFRC 270 New Sierra Pacific Windows - Fr Dr. 1 Zone 1 - Bedrooms 10 Window 10.0 0.340 NFRC 0.25 NFRC 270 New Sierra Pacific Windows - DH . Lo Zone 1 - Bedrooms 11 Window 10.0 0.340 NFRC 0.25 NFRC 270 New Sierra Pacific Windows - DH .Lo Zone 1 - Bedrooms 12 Window 11.0 0.340 NFRC 0.25 NFRC 180 New Sierra Pacific Windows - DH .Lo Zone 2 - Bedroom 2nd Floor 13 Window 5.0 0.320 NFRC 0.27 NFRC 90 New Sierra Pacific Windows - Fix Ic Zone 2 - Bedroom 2nd Floor 14 Window 5.0 0.320 NFRC 0.27 NFRC 90 New Sierra Pacific Windows - Fix Lc Zone 2 - Bedroom 2nd Floor 15 Window 5.0 0.320 NFRC 0.27 NFRC 90 New Sierra Pacific Windows - Fix Ic Zone 2 - Bedroom 2nd Floor 16 Window 5.0 0.320 NFRC 0.27 NFRC 0 New Sierra Pacific Windows -Fix .L Zone 2 - Bedroom 2nd Floor (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 8.0 3.0 1.0 12.0 0 0.0 0.0 0 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 8.0 6.0 6.0 0.1 6.0 6.0 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 . V 13 Bug Screen 0.76 14 Bug Screen 0.76 jf L 11.f f ` P 15 Bug Screen 0.76 A, ;� � � . n 16 JBug Screen 0.76 Cp�STRV'TION Ener Pro 5.1 by Ener Soft User Number: 5732 RunCode: 2013-0 0'1'0' :29:57 ID: 1 043013 Pae 7 of 17 f,. CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name CLARK & SOLIS DEVELOPMENT LLC Building Type 21 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1413012013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 392 0.069 R-21 90 90 New 4.3.1-A6 Zone 3 - Living, Dining, B Wall 17 0.069 R-21 0 90 New 4.3.1-A6 Zone 3 - Living, Dining, 8 Wall 359 0.069 R-21 270 90 New 4.3.1-A6 Zone 3 - Living, Dining, B Roof 1,169 0.025 R-38 0 0 New 4.2.1-A21 Zone 3 - Living, Dining, 8 Slab 199 0.730 None 0 180 New 4.4.7-A1 Zone 4 - Fam, Kit, Off, Bath, Slab 1,103 0.730 None 0 180 New 4.4.7-A1 Zone 4 - Fam, Kit, Off, Bath, Wall 311 0.069 R-21 180 90 New 4.3.1-A6 Zone 4 - Fam, Kit, Off, Bath, Wall 97 0.069 R-21 90 90 New 4.3.1-A6 Zone 4 - Fam, Kit, Off, Bath, Wall 268 0.069 R-21 270 90 New 4.3.1-A6 Zone 4 - Fam, Kit, Off, Bath, Wall 210 0.069 R-21 270 90 New 4.3.1-A6 Zone 4 - Fam,Kit, Off, Bath, Door 23 0.500 1 None 270 90 1 New 4.5.1-A4 Zone 4 - Fam,Kit,Off, Bath, Floor 459 0.034 R-30 0 180 New 4.4.2-A7 Zone 4 - Fam, Kit, Off, Bath, Wall 239 0.069 R-21 180 90 New 4.3.1-A6 Zone 4 - Fam, Kit, Off, Bath, Wall 130 0.069 R-21 90 90 New 4.3.1-A6 Zone 4 - Fam, Kit, Off, Bath, Wall 1 251 0.069 R-21 0 90 New 14.3.1-A6 Zone 4 - Fam, Kit, Off, Bath, Wall 1 144 0.069 R-21 270 90 New 14.3.1-A6 Zone 4 - Fam, Kit, Off, Bath, FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 0-7-� Window 15.0 0.340 NFRC 0.25 NFRC 0 New Sierra Pacific Windows - DH . Lo Zone 2 - Bedroom 2nd Floor (S 18 Window 48.0 0.330 NFRC 0.26 NFRC 270 New Sierra Pacific Windows - Fr Dr. L Zone 2 - Bedroom 2nd Floor `19" ,Window 240.0 0.440 NFRC 0.24 NFRC 90 New Fleetwood -Norwood 3070 Zone 3 - Living, Dining, Bar 20 'Window 73.0 0.320 NFRC 0.31 NFRC 90 New Sierra Pacific Windows - Cas I Zone 3 - Living, Dining, Bar �21 Window 2.3 0.320 NFRC 0.27 NFRC 90 New Sierra Pacific Windows - Fix Lc Zone 3 - Living, Dining, Bar "22 ,Window 2.3 0.320 NFRC 0.27 NFRC 90 New Sierra Pacific Windows - Fix Lc Zone 3 - Living, Dining, Bar _23_ Window 2.3 0.320 NFRC 0.27 NFRC 90 New Sierra Pacific Windows - Fix Ic Zone 3 - Living, Dining, Bar _24, Window 2.3 0.320 NFRC 0.27 NFRC 90 New Sierra Pacific Windows - Fix Lc Zone 3 - Living, Dining, Bar ( 25 Window 2.3 0.320 NFRC 0.27 NFRC 90 New Sierra Pacific Windows - Fix Lc Zone 3 - Living, Dining, Bar C-26_ Window 2.3 0.320 NFRC 0.27 NFRC 90 New Sierra Pacific Windows - Fix .L Zone 3 - Living, Dining, Bar 27 * Window 80.0 0.440 NFRC 0.24 NFRC 270 New Fleetwood -Norwood 3070 Zone 3 - Living, Dining, Bar 1-28-, Window 24.0 0.320 NFRC 0.27 NFRC 270 New Sierra Pacific Windows - Fix Lc Zone 3 - Living, Dining, Bar 29 Window 1 54.01 0.330 1 NFRC 0.26 NFRC 270 New Sierra Pacific Windows - Fr Dr. L Zone 3 - Living, Dining, Bar 30- Window 80.0 0.440 1 NFRC 0.24 NFRC 270 New Fleetwood -Norwood 3070 Zone 3 - Living, Dining, Bar a3-1- 1Nndow 24.01 0.320 1 NFRC 0.27 NFRC 270 New Sierra Pacific Windows - Fix Lc Zone 3 - Living, Dining, Bar 32 Window 1 48.01 0.330 1 NFRC 0.26 NFRC 180 New Sierra Pacific Windows - Fr Dr. Zone 4 - Fam, Kit, Off, Bath, Lau (1) 1 -1 -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hot Wd Ove hang Left Fin Len H t LExt REA Dist Len Right Fin H t Dist Len Hot 17 Bug Screen 0.76 18 Bug Screen 0.76 8.0 6.0 10.0 0.1 10.0 10.0 19 Bug Screen 0.76 10.0 24.0 14.0 0.5 11.0 11.0 1.0 9.8 0 11.0 4.5 0 20 1Bug Screen 0.76 7.3 10.0 14.0 0.5 11.0 11.0 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 R� , 27 Bug Screen 0.76 """ f r ) 28 Bug Screen 0.76 1 i 1: r w. A A - 29 Bug Screen 0.76 9.0 6.0 5.5 0.1 .0 2.Q L' �,=� ''r1A 1 30 Bu Screen 0.76 10.0 8.0 5.3 4.7 .7 3 5 i - 5.5 a �5: • .5 0 0:+7 31 Bu Screen 0.76 3.3 8.0 5.3 0.7 0.7 ,r5 32 Bug Screen 0.76 8.0 6.0 10.0 0.1 0.0 10:0" SATE _ �r1pN Ene Pro 5.1 b Ener Soft User Number. 5732 RunCode: 2013-04-30 6-4:29: t7 ID -1 O V13 Page 8 of 17 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name CLARK & SOLIS DEVELOPMENT LLC Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/30/2013 OPAQUE SURFACE DETAILS Surface U Insulation Joint Appendix Type Area Factor CavitylExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,302 0.025 R-38 0 0 New 4.2.1-A21 Zone 4 - Fam, Kit, Off, Bath, FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 20.0 0.320 NFRC 0.27 NFRC 90 New Sierra Pacific Windows- Fix Ic Zone 4 - Fam,Kit,Off,Bath,Lau 34 Window 48.0 0.330 NFRC 0.26 NFRC 90 New Sierra Pacific Windows - Fr Dr.1 Zone 4 - Fam,Kit, Off, Bath, Lau 35 Window 20.0 0.320 NFRC 0.27 NFRC 90 New Sierra Pacific Windows- Fix Ic Zone 4 - Fam,Kit,Off,Bath,Lau 36 Window 4.0 0.320 NFRC 0.27 NFRC 270 New Sierra Pacific Windows- Fix Ic Zone 4 - Fam,Kit,Off,Bath,Lau 37 Window 4.0 0.320 NFRC 0.27 NFRC 270 New Sierra Pacific Windows- Fix Ic Zone 4 - Fam,Kit,Off,Bath,Lau 38 Window 4.0 0.320 NFRC 0.27 NFRC 270 New Sierra Pacific Windows- Fix Ic Zone 4 - Fam,Kit,Off,Bath,Lau 39 Window 26.0 0.320 NFRC 0.31 NFRC 270 New Sierra Pacific Windows- Cas I Zone 4 - Fam,Kit,Off,Bath,Lau 40 Window 23.0 0.320 NFRC 0.31 NFRC 270 New Sierra Pacific Windows - Cas I Zone 4 - Fam,Kit, Off, Bath, Lau 41 Window 15.0 0.340 NFRC 0.25 NFRC 270 New Sierra Pacific Windows - DH .Lo Zone 4 - Fam,Kit,Off, Bath, Lau, 42 Window 15.0 0.340 NFRC 0.25 NFRC 270 New Sierra Pacific Windows - DH .Lo Zone 4 - Fam,Kit, Off, Bath, Lau 43 Window 24.0 0.330 NFRC 0.26 NFRC 180 New Sierra Pacific Windows - FrDr.1 Zone 4 - Fam,Kit, Off, Bath, Lau 44 Window 7.0 0.340 NFRC 0.25 NFRC 90 New Sierra Pacific Windows - DH. Lo Zone 4 - Fam, Kit, Off, Bath, Lau '45 Window 7.0 0.340 NFRC 0.25 NFRC 90 New Sierra Pacific Windows - DH .Lo Zone 4 - Fam,Kit, Off, Bath, Lau 46 Window 6.0 0.340 NFRC 0.25 NFRC 0 New Sierra Pacific Windows - DH .Lo Zone 4 - Fam,Kit, Off, Bath, Lau 47 Window 6.0 0.340 NFRC 0.25 NFRC 0 New Sierra Pacific Windows - DH .Lo Zone 4 - Fam, Kit, Off, Bath, Lau 48 . Window 96.0 0.440 NFRC 0.24 NFRC 270 New Fleetwood -Norwood 3070 Zone 4 - Fam, Kit, Off, Bath, Lau (1) Ll -Factor Type: 2 SHGC Type: 116 A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC Hat Wd Ove hanq Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 �-� 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 JBug Screen 0.76 48 JBug Screen 0.76 DA -r& Ener Pro 5.1 by Ener Soft User Number.- 5732 RunCode: 2013-04-30704:29:57 430 Page 9 of 17 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name CLARK & SOLIS DEVELOPMENT LLC Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1413012013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built HVAC System - Zone 1 Bedrooms 1,997 15,976 HVAC System - Zone 2 Bedroom 2 573 5,157 HVAC System - Zone 3 Living, Dining, Bar 1,196 20,093 HVAC System - Zone 4 Fam-Kit-Off-Laundry-Casita 1,761 15,849 Totals 1 5,5271 01 0 01 1 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System - Zone 1 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC System - Zone 2 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC System - Zone 3 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC System - Zone 4 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R -Value Tested? Status HVAC System - Zone 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC System - Zone 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC System - Zone 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 d New HVAC System - Zone 4 Ducted Ducted lAttic, Ceiling Ins, vented 1 8.01 IZI I New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input (Btu h) Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status A O Smith Water Products 2 Large Gas All Pipes Ins 80,000 74 0.78 0.00% n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft C O -075 y cPipe v`a/�IenY:a aLe th— Pipe iameter Insul. Thick. Q HP Plenum Outside Buried ❑ i �y ❑ -e W — T ❑ 1-1 O VC ❑ ' T E Ener Pro 5.1 6 Ener Soft User Number: 5732 RunCode: 2013-04-30 0" 0 3 Pae 10 of 17 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF-1 R Project Name CLARK & SOLIS DEVELOPMENT LLC Date 4/30/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF-1 R Form. *§1 50a : Minimum R-19 insulation in wood-frame ceiling orequivalent U-factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§1 50c : Minimum R-13 insulation in wood-frame wall orequivalent U-factor. *§1 50d : Minimum R-13 insulation in raised wood-frame floor orequivalent U-factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 1 50: Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150(e)1A: Mason or facto -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is eq ui ed with a with a readily accessible, operable, and tight-fitting damper and or a combustion-air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113 c 5. §115: Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §1500): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water-heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and pingJ sulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water sy terns'>t psi,lme�ets he-r ements of Standards Table 123-A. 11.... 1 50' 3A: Insulation is protected from damage, includingthat due to sunli ht, moisture eVui r8e f ;;aJnten le', d in . §150(j)3A: Insulation for chilled water piping and refrigerant suction lines i eludes a4vap© re tardan or igen o eratirel in conditioned space. r "I 150(j)4: Solar water-heating systems and/or collectors are certified by t e Solar Ratin an C�ertiili6' iM o oration. DATE IN EnergyPro 5.1 by EnergySoR User Number: 5732 RunCode: 2013-04-30704:29:57 0 3 Page 11 of 17 4. MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date CLARK & SOLIS DEVELOPMENT LLC 4/30/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and-atility ,oms are high efficacy and controlled by a manual -on occupant sensor. (� §150(k)9: Permanently installed lighting that is internal to cabinets shall use o more than 2Qyuattslof�poy�e� of of illuminated cabinet. 8011 la.,,, ���''11 T DEPT, FOR CONSTRUE N EnergyPro 5.1 by EnergySoff User Number: 5732 RunCode: 2013-04-3OY 4`14:57 ID: 1043013 Page 12 of 17 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date CLARK & SOLIS DEVELOPMENT LLC 1413012013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. ° �r & L'4' C,�U,�� ��AFE� DEP R DONST. OV CD ETp T1 pN _ BY EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2013-04-30704:29:57 ID: Ig043013 age 13 of 17 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name CLARK & SOLIS DEVELOPMENT LLC Date 4/30/2013 System Name HVAC System - Zone 1 Floor Area 1,997 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. CFM Sensible Latent CFM 850 17,693 2,756 425 0 834 0 0 0 0 0 1 0 1 834 1 19,360 2,756 PEAK Heating System Sensible Output per System 80.000 16,604 Total Output stun 80,000 Output Btuh/s ft 40.1 634 Cooling System 0 Output per System 57,0001 0 Total Output Btuh 57,000 0 Total Output Tons 4.8 634 Total Output Btuh/s ft 28.5 Total Output s ft/Ton 420.4 17,872 Air System CFM per System 1,800 HVAC EQUIPMENT SELECTION Airflow cfm 1,800 YorkCZB60.PS8CN100.2000cfm 40,440 7,899 80,000 Airflow cfm/s ft 0.90 Airflow cfmfron 378.9 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 1 40,440 7,899 80,000 Aug 3 PM I Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF Outside Air P- 0 cfm Supply Fan 1,800 cfm 68 OF 68 OF 105 OF Heating Coil i E � 105 OF ROOM IYI 68 OF I COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 75/62°F Outside Air 0 cfm 75 162 OF 75/62°F 55/54°F Cl I Supply Fan O� 55 / 54 OF 'N n viLD G LA �! _ _ 1,800 cfm Cooling Coil BLD/NG �p �& 5 +��1Y FSR vv'QNS� V ZD 75 / 62 °F !— Atjr,-, 7-1 TE BY EnergyPro 5.1 by EnergySoff User Number: 5732 RunCode: 2013-04-30704:29:57 301 Page 14 of 17 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name CLARK & SOLIS DEVELOPMENT LLC Date 4/30/2013 System Name HVAC System - Zone 2 Floor Area 573 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 273 0 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 32,000 5,714 876 149 5,833 Total Output Btuh 32,000 0 Output Btuh/s ft 55.8 269 223 Cooling System 0 0 Output per System 23200 0 0 0 0 Total Output Btuh 23:200 0 876 0 Total Output ons 1.9 269 223 Total Output Btuh/s ft 40.5 Total Output s ft/Ton 296.4 6,252 6,278 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 YorkCZB24.PS8Al2N40.800cfm 16,689 2,927 32,000 Airflow cfm/s ft 1.40 Airflow cfm/Ton 413.8 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 16,689 2,927 32,000 Aug 3 PM I Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF Outside Air 0 cfm Supply Fan 800 cfm 68 OF 68 OF 105 OF Heating Coil 105 OF ROOM .P 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 75/62°F Outside Air 0 cfm AL 75 / 62 °FF 75/62°F 55/54°F — Supply Fan Cooling Coil � O� 55 154 OF F,/ 800 cfm _ �����NG (Qg0/6 � ORr Jr'�® EPT 75 / 62 OF oaTE UCTION EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2013-04-30704:29:57 7f-g04&V 3 Page 15 of 17 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name CLARK & SOLIS DEVELOPMENT LLC Date 4/30/2013 System Name HVAC System - Zone 3 Floor Area 1,196 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 984 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 80,000 20,265 1,411 448 17,416 Total Output Btuh 80,000 0 Output Btuh/s ft 66.9 955 665 Cooling System 0 0 Output per System 41,500 0 0 0 0 Total Output Btuh 41,500 0 1,4111 0 Total Output ons 3.5 955 665 Total Output Btuh/s ft 34.7 Total Output s ft/Ton 345.8 1 22,174 ,745 Air System CFM per System 1,400 HVAC EQUIPMENT SELECTION Airflow cfm 1,400 YorkCZB42.PS8C20N100.1400cfm 30,571 4,550 80,000 Airflow cfm/s ft 1.17 Airflow cfm/Ton 404.8 Outside Air % 0.0% Total Adjusted System Output 30,571 4,550 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 80,000 I Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF Outside Air 0 cfm Supply Fan 1,400 cfm 68 OF 68 OF 105 OF — Heating Coil 105 OF ROOM 68 OF I COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 76/62°F 76/62°F 55/54°F o Outside Air ^' ° 0 cfm Supply Fan Cooling Coil (� 56 / 54 F & ��. _. r..�.._.. 1,400 cfm BUILDING 76 / 62 OF FOR O 5 / 62 OF NST !DATE EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2013-0430T04:29:57-----IDS 0430 Page 16 of 17 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name CLARK & SOLIS DEVELOPMENT LLC Date 4/30/2013 System Name HVAC System - Zone 4 Floor Area 1,761 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 1,123 o COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 80,000 23,217 2,478 470 18,331 Total Output Btuh 80,000 0 Output Btuh/s ft 45.4 1,094 700 Cooling System 0 0 Output perSystem 57,000 0 0 0 0 Total Output Btuh 57,000 0 2,478 0 Total Output Tons 4.8 1,094 700 Total Output Btuh/s ft 32.4 Total Output s ft/Ton 370.7 1 25,405 19,730 Air System CFM perSystem 1.800 HVAC EQUIPMENT SELECTION Airflow cfm 1,800 YorkCZB60.PS8CN100.2000cfm 40,708 7,618 80,000 Airflow cfm/s ft 1.02 Airflow cfmfl-on 378.9 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 1 40,708 7,618 80,000 AZTR PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF Outside Air 0 cfm Supply Fan AL 1,800 cfm 68 OF 68 OF 105 OF Heating Coil — — 105 OF n00M 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 76/62°F 76/62°F 55/54°F o '- Outside Air - 0 cfm Supply Fan AL Cooling Coil 1,800 cfm / 62 °F ..4 34 4 OF rUILDI F�UIN.T .76 oNS�� .._75 62 OF DATE 0. BY EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2013-04-30704:29:57 �qage 17 of 17 Electronically Filed by Santiago Lopez-Ocampo and Authenticated at CalCERTS.com - 4/30/2013 "' k ti PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name CLARK & SOLIS DEVELOPMENT LLC Building Type m Single Family ❑ Addition Alone . ❑ Multi Family ❑ Existing+ Addition/Alteration 1413012013 Date Project Address LOT 235 VIA PALACIO La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,527 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Slab Unheated Slab -on -Grade None 4,468 Perim = 0' ew Wall Wood Framed R-21 3,379 IVXNe Wall Wood Framed R-21 1,432 X w Demising Wood Framed w/o Crawl Space R-30 1,389 New Roof Wood Framed Attic R-38 4,365 Radiant Barrier w Door Opaque Door None 23 ew AM M FENESTRATION U- E, t7rL�; U?^," Orientation Area ft2 Factor SHGC OverhangS efins eek - ` ` Status Right (S) 42.6 0.330 0.26 none no g Screen �"'11:'VTN5w Right (S) .�.,, 34.0 0.320.E .,0.31—..none-y_none _Bug Screener-._, w Right (S)rr ` 24.0 `r 0.330 L 0.26 none"*'V 12.01'0.0 Bug Screen V New Rear (E) ,123.0 _0.330 0.21 JO& jI'Nevo Bug Screen 11 New Left (N) {r X87.0 ;� ` k 0.340 0,.`25 none f ne Bug Screen_ New' (IM. '( 1 1 �._.,,,{f% , �_ ,,� .Bug Screen; , s�-.{�fi �,��� New Front '148.00.330,-1' -6. 6.0 none +/- `" \' Front (IM 50.0 0.340 25 none Bug Screen New Right (S) 11.0 0.340 10V .25 non r none Bug Screen New Rear (E) 68.8 0.3200%,none none Bug Screen New Left (N) 5.0 - ,PJ2,0 XO.27 none none Bug Screen New Front (W) 48.0 0.330 X26 10.0 none, Bug Screen New HVAC SYSTEMS J% k I Oty. Heatingin. Eff Coolin Min. Eff Thermostat Status 1 Central Fumac. 8A FUE Split Air Conditioner 13.0 SEER Setback New 1 Central Fu _• c 8�0% AFUE Split Air Conditioner 13.0 SEER Setback New 1 Centra ce 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC MTRIB lowr Duct Locati8wX Heating Cooling Duct Location R -Value Status HVAC System - Zo Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC System - Zone 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC System - Zone 3 Ducted Ducted Attic,Cel in Ins, -vented ------_8 0 New WATER HEATING I Y OF LA QUANTA Ot . Type Gallons Min. Eff DfS1tk buti0--A & tatus 2 Large Gas 74 0.78 All Pipes-(ns3 ;?' ` , \ New FOB o 'LJ DATE EnergyPro 5.1 by Ener Soft User Number., 5732 RunCode: 2013-04-30_T-0 9:57 Pae 1 of 8 Reg: 213-N0025645A-000000000-0000 Registration Date/Time: 2013/04/30 07:41:09 HERS Provider: a RTS, Inc Electronically Filed by Santiago Lopez-Ocampo and Authenticated at CalCERTS.com - 4/30/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name CLARK & SOLIS DEVELOPMENT LLC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/30/2013 Project Address LOT 235 VIA PALACIO La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,527 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Vr FENESTRATION U- Orientation Area(ft) , Factor Exter SHGC Overhang SJ efins Shad-- Status Rear (E) 240.0 0.440 0.24 14.0 9. .5 g Screen New Rear (E) _ _ 73.00.320-jww%�,40.31-140-1 none ..Bug,Screen New .' Front (lM'' 176.0 1 440 � 0.24 none r none', j ,Bug Screen New Front (1A0 036.0 �.i 0.320 0.27 » - Bug Screen `, t% New Front 4) A ,, 54.0 0.330 0'26 .5 %. 1 ne _ .J Bug Screen . /",� jMew Front (W),_ Ile „"O'e6o.6 E '@ 0.440'(—,6. 5.3 t5.5/5.5z ' , Bug Screenl -I,/ t rNew Front (tM 24.0 0.320 27 none Bug Screen New Right (S) - 48.0 0.330 .26 10. none Bug Screen New Rear (E) 48.0 0.33 none none Bug Screen New Front (140 49.00 0.31 one none Bug Screen New Rear (E) 14.0 0. 3 4'0*4 none none Bug Screen New HVAC SYSTEMS Ot . Heating in. E Cooling Min. Eff Thermostat Status 1 Central Furnac 8%M°"a FUE Split Air Conditioner 13.0 SEER Setback New HVAC VTRIBIIO LocatiUnX Heating Duct Cooling Duct Location R -Value Status HVAC System - Zo Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING SA' %- Y �!< H Ot . Type Gallons Min. Eff Distribution RLL: OESat s Ft�F :n1'. f� r ... 1-1 1 ION DATE Ener Pro 5.1 by EnergySoft User Number 5732 RunCode: 2013-04-30704:29:57 ID: 1 043013 e 2 of 8 Reg: 213-N0025645A-000000000-0000 Registration Date/Time: 2013/04/30 07:41:09 HERS Provider: CalCERTS, Inc Electronically Filed by Santiago Lopez-Ocampo and Authenticated at CalCERTS.com - 4/30/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name CLARK & SOLIS DEVELOPMENT LLC Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/30/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System A O Smith Water Products FPSH-75 is a non-NAECA large storage gas water heater. Verify DHW details. HIGH MASS Design - Verify Thermal Mass: 1,034.0 ft2Covered Slab Floor, 4.000" thick at Bedrooms HIGH MASS Design - Verify Thermal Mass: 963.0 ft' Exposed Slab Floor, 4.000" thick at Bedrooms HIGH MASS Design - Verify Thermal Mass: 1,169.0 ft2 Exposed Slab Floor, 4.000" thick at Living, Dining, Bar HIGH MASS Design - Verify Thermal Mass: 199.0 ft' Covered Slab Floor, 4.000" thick at Fam-Kit-Off-Laundry-Casita HIGH MASS Design - Verify Thermal Mass: 1,103.0 ft2 Covered Slab Floor, 4.000" thick at Fam-Kit-Off-Laun , - sr The Roof R-38 Roof Attic w/Radiant Barrier includes credit for a Radiant Barrier that is Continuousmee g e1igib,1,tVTinstA6tion criteria as specified in Residential Appendix RA4.2.2. GREEN - HERS REQUIRED VERIFICATIO Items in this section require field testing and/orer)Oby a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the mea liste elo for final to be given. The Cooling System YorkCZB60.PS8CN100.2000 includes credit 1.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.11 The HVAC System HVAC System - Zone 1 incorpoS Verified Refrigerant Charge or a Charge Indicator Display. A.M.... rX , The HVAC System HVAC System - Zo 1 Inco . tes verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the sp fied criteria. The Cooling System YorkCZB2 LL S8 2N40.600cf includes credit for a 11.3 EER Condenser. A certified HERS rater must field verify the installation of the correct Con The HVAC System HVAC System - ne orates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System -AC -° tem - 6AR-e incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct le eets a sp cified criteria. The Cooling S0stem Yo a B42. 8C20N100.1400chn includes credit for a 11.4 EER Condenser. A certified HERS rater must field verify the installation r e correct en er. The HVAC Sys HVAC S tem - Zone 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HM System - Zone 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System YorkCZB60.PS8CN100.2000cfm includes credit for a 11.2 EER C rid ase . rA erg` d HELS�,ate�us d-ve installation of the correct Condenser. i r-,/`-� U The HVAC System HVAC System - Zone 4 incorporates HERS Verified Refrigerant Cht rge o raCh arcj I'T"eAtorplp 1a. Q e--. The HVAC System HVAC System - Zone 4 incorporates HERS verified Duct Leakage. HERS f Id vdrifi atioh d d a'rV6,. tic`t�ing is req ired to verify that duct leakage meets the specified criteria. �OR CO TFi DA Ener Pro 5.1 by Ener Soft User Number: 5732 RunCode: 2013-04-30T94;29,;,5_7 e43 Page 3 of 8 Reg: 213-N0025645A-000000000-0000 Registration Date/Time: 2013/04/30 07:41:09 HERS Provider: Ca S, Inc Electronically Filed by Santiago Lopez-Ocampo and Authenticated at CalCERTS.com - 4/30/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date CLARK & SOLIS DEVELOPMENT LLC ❑ Multi Family ❑ Existing+ Addition/Alteration 1413012013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 4.40 5.12 -0.72 Space Cooling 54.39 52.39 2.00 Fans 10.87 13.77 -2.90 Domestic Hot Water 6.21 4.17 2.04 Pumps 0.00 0.00 0.00 Totals 75.87 75.44 0.43 Percent Better Than Standard: 0.6 BUILDING COMPLIES - HERS VERIFICATION RE RED estration Building Front Orientation: (W 270 deg Ext. Walls/Roof ria Area Number of Dwelling Units: 1.00 (vv) 565 Fuel Available at Site: Natural Gas (N) 82 92 Raised Floor Area: 459 (E) 1,529 567 Slab on Grade Area: 4,468 (S) 697 160 4,365 0 Average Ceiling Height: 10.3;'�%nestra Fenestration Average U -Factor: 0.37 TOTAL: 1,383 Avera e SHGC: 0.25 teHCFA Ratio: 25.0% REMARKS A 4 STATEMENT OF COMPLIANC This certificate of compliance lists the bui features and specifications needed to comply with Title 24, Parts 1 tkpr#4minist a egulations and Part 6 the Efficiency Standards of the Carornia EN,of gulations. The documentation aut , r er . certifie that the documentation is accurate and complete. Documentation utho Company Santia - p 4/30/2013 Address P. 101 Name Cit /State/Z' a Quint , a 92 Phone 760.485.8927 Signed Date The indi id with ov II design responsibility hereby certifies that the proposed building design represented in this set of construction docu nts is consistent with the other compliance forms and worksheets, with the specifications, and with any other ca ett ations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Y OF QUPNTA J.E.D. DESIGNS. Designer or Owner (per Business & Professions Code)FDEaLGADO Company DING & SAFETY DEPT. Address 45175 PANORAMA DRIVE, SUITE A" Name JOSE ENRIQUEPALM DESERT, CA 92260 Phone (760) 485-3119n Li�ehse # Date City/StatelZip Fi GUNS Ener Pro 5.1 by Ener Soft User Number.' 5732 RunCode: 2013-04-30T0 - Z ID: 1043013 1 Page 4 of 8 Reg: 213-N0025645A-000000000-0000 Registration Date/Time: 2013/0'" 4� i �g HERS Provi er Inc Electronically Filed by Santiago Lopez-Ocampo and Authenticated at CalCERTS.com - 4/30/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name CLARK & SOLIS DEVELOPMENT LLC Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1413012013 OPAQUE SURFACE DETAILS Surface -Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 1,034 0.730 None 0 180 New 4.4.7-A1 Zone 1 - Bedrooms Slab 963 0.730 None 0 180 New 4.4.7-A1 Zone 1 - Bedrooms Wall 643 0.069 R-21 180 90 New 4.3.1-A6 Zone 1 - Bedrooms Wall 222 0.069 R-21 90 90 New 4.3.1-A6 Zone 1 - Bedrooms Wall 397 0.069 R-21 0 90 New 4.3.1-A6 Zone 1 - Bedrooms Wall 283 0.069 1 R-21 270 90 New 4.3.1-A6 Zone 1 - Bedrooms Demising 465 0.034 R-30 0 90 New 4.4.2-A7 Zone 1 - Bedrooms (faces Roof 1,321 0.025 R-38 0 0 New 4.2.1-A21 one 1 - 8 drooms Demising 465 0.034 R-30 0 90 New 4.4.2-A7 Zone 2 - B °• om 2nd Flo Wall 238 0.069 R-21 180 90 New 4.3.1-A6 , e 2 - Be -om 2nd Flo Wall 121 0.069 R-21 90 90 New 4.3.1-A6 Zo ' - B room 2nd Flo Wall 225 0.069 R-21 0 90 New 4.3.1-A6 Zone Bedroom 2nd Flo Wall 159 0.069 R-21 270 90 New 4.3.1-A o -Bedroom 2n1 Flo Roof 573 0.025 R-38 0 0 New 4.2.1-A21 e 2 - Bedroom 2nd Flo Slab 1,169 0.730 None 0 180 New Al one 3 - Livin , Dining, BE Wall 107 0.069 R-21 180 90 New 1-A6 Zone 3 - Living, Dinin , B FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC2 Azm Status Glazing Location/Comments 1 Window 18.6 0.330 NFRC 0.26 NFRC 180 Newa ifrc Window Fr Dr. I Zone 1 - Bedrooms 2 Window 34.0 0.320 NFRC 0.31 NFRC 180 New Arierra Pacific WindoM - Cas I Zone 1 - Bedrooms 3 Window 24.0 0.330 NFRC 0.26 NFRC 180 New ierra Pacific l ndows - Fr Dr. I Zone 1 - Bedrooms 4 Window 123.0 0.330 NFRC 0.21 NFRC 90 Ne& 1krra Pacific endows - SGD IL Zone 1 - Bedrooms 5 Window.,. 15.0 0.340 NFRC ,0.25 NFRC,__",_ _• 0 w � Si ` endows - DH .Lo Zone 1 - Bedrooms 6 Window` 'x,15.0 0.340 NFRC...d �'`'0.25 NFRC - ; "' " Sierra Pacific Windows = DH .Lo Zone 1 -Bedrooms 7 Window .15.0 0.340 NFRC 1 0.25 NFRC Ne Sierra Pacific Windows - DH .Lo Zone 1 - Bedrooms 8 Window 15;0.:;:0.340 NFRC 0.25 NFRC 0 New a Pacific Windows: DH.Lo Zone 1 - Bedrooms 9 Window 48:0 10.330 NFRC 0.26 NFRC c 0 New ierra Pacific Windows= Fr Dr.. Zone 1,-. Bedrooms, 10 Window tI 1 f0.0 0.340 NFRC 0.25 70 New . Sierra Pacific Windows - DH. Lo Zone 1 -Bedrooms 11 Windows r �,10.0 , 0.340 NFRC •-0.25 + New 1. Sierra Pacific Windows-DH:LoZone;1'-Bedrooms" ic 12 Window 11.0 0.340 NFRC 0.25C 180 New Sierra Pacific Windows - DH. Lo Zone 2 - Bedroom 2nd Floor 13 Window 5.0 0.320 NFRC 0 ew Sierra Pacific Windows - Fix .L Zone 2 - Bedroom 2nd Floor 14 Window 5.0 0.320 NFRC 27AMC New Sierra Pacific Windows - Fix .L Zone 2 - Bedroom 2nd Floor 15 Window 5.0 0.320 NFRC 7 � 90 New Sierra Pacific Windows - Fix .L Zone 2 - Bedroom 2nd Floor 16 Window 5.0 0.320 NFRC 0. FRC 0 New Sierra Pacific Windows - Fix .L Zone 2 - Bedroom 2nd Floor (1) LI -Factor Type: 116-A = ble fro - tt ards, NFRC = Labeled Value 2 SHGC Type: 116 B efauIt T " rl from ". ndards, NFRC =Labeled Value EXTERIOR SHADING DETAIMS ID w1hdow Exterior Shade Ty4eAks Wd Ove hang Left Fin Ri ht Fin Len H t LEA RExt Dist Len I H t Dist I Len Hot 1 Bug Screen 0.76 2 Bug Screen 76 3 Bug Screen 76 8.0 3.0 1.0 12.0 0 0.0 0.0 0 4 Bug Scree 0.76 5 Bug S. en 0.76 6 Bu qn 0.76 7 Bug Scre #0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 8.0 6.0 6.0 0.1 6.0 6.0 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 I +,' e t ➢ I 14 Bug Screen 0.76 -T -801i I KIrZ A r, 15 Bug Screen 0.76 _ - - 1 L A 16 Bug Screen 0.76 jam',, ` 4 JfC7f N FOR CONSTRUCTION Ener Pro 5.1 by Ener Soft User Number: 5732 RunCode: 2013-04-30T04:2 :57 ID: 1043013 Pa 5 of 8 Reg: 213-N0025645A-000000000-0000 Registration Date/Time: 2013/04/30 07:41:09 c Electronically Filed by Santiago Lopez-Ocampo and Authenticated at CalCERTS.com - 4/30/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name CLARK & SOLIS DEVELOPMENT LLC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1413012013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 392 0.069 R-21 90 90 New 4.3.1-A6 Zone 3 - Living, Dining, B Wall 17 0.069 R-21 0 90 New 4.3.1-A6 Zone 3 - Living, Dining, 8 Wall 359 0.069 R-21 270 90 New 4.3.1-A6 Zone 3 - Living, Dinin , B Roof 1,169 0.025 R-38 0 0 New 4.2.1-A21 Zone 3 - Living, Dining, 8 Slab 199 0.730 None 0 180 New 4.4.7-A1 Zone 4 - Fam, Kit, Off, Bath, Slab 1,103 0.730 None 0 180 New 4.4.7-A1 Zone 4 - Fam, Kit, Off, Bath, Wall 311 0.069 R-21 180 90 New 4.3.1-A6 Zone 4 - Fam, Kit, Off, Bath, Wall 97 0.069 R-21 90 90 New 4.3.1-A6 4, 12one 4 - F m, Kit, Off, Bath, Wall 268 0.069 R-21 270 90 New 4.3.1-A6 one 4 - Fa it,Off,Bath, Wall 210 0.069 R-21 270 90 New 4.3.1-A6 e 4 - Fa ',Off,Bath, Door 231 0.500 None 270 90 New 4.5.1-A4 Zo II - WA,Kit, Off, Bath, Floor 459 0.034 R-30 0 180 New 4.4.2-A7 Zone yFam. it,Off,Bath, Wall 239 0.069 R-21 180 90 New 4.3.1-A• Zp-Fam,Kit,Off,Bath, Wall 130 0.069 R-21 90 90 New 4.3.1-A6 e 4 - Fam,Kit, Off Bath, Wall 251 0.069 R-21 0 90 New 1-A6 Vone 4 - Fam,Kit,Off,Bath, Wall 144 0.069 R-21 270 90 New 1-A6 Zone 4 - Fam,Kit, Off Bath, FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status IkGlazinq Location/Comments 17 Window 15.0 0.340 NFRC 0.25 NFRC 0 New ' a ' ifrc Window,17bH. Lo Zone 2 - Bedroom 2nd Floor 18 Window 48.0 0.330 NFRC 0.26 NFRC 270 New ffierra Pacific WindoM - Fr Dr. I Zone 2 - Bedroom 2nd Floor 19 Window 240.0 0.440 NFRC 0.24 NFRC 90 New Irleetwood-Norpvood 3070 Zone 3 - Living, Dining, Bar 20 Window 73.0 0.320 NFRC 0.31 NFRC 90 Ne rra Pacific endows - Cas .L Zone 3 - Living, Dining, Bar 21 Window__ ._., ,2.3 0.320 NFRC ,0.27, NFRC,,_,..____90 Si ir.&Windows - Fix,.Lc Zone 3 -Living, Dining, Bar 22 Window' \12.3 0.320 NFRC ,,,v r 0.27 NFRC _)9%" Sierra Pacific Windows"- Fix Lc Zone 3 - Living, Dining, Bar 23 Window 2.3 0.320 NFRC l 0.27 NFRC Ne Sierra Pacific Windows - Fix Lc Zone 3 - Living, Dining, Bar 24 Window 2,3::; 0.320 NFRC 0.27 NFRC 90 New Pacific Windows - Fix,, .L Zone 3 - Living, Dining, Bar 25 Window 2.3 10.320 NFRC 0.27 NFRC +i 0 New , rerra Pacific Windows-- Fix Lc Zone 3-.Living,,Dining,•Bar 26 Window A ! 2.3 r 0.320 NFRC 0.27 NF„R '90 New... Sierra Pacific Windows - Fix .L Zone - Living,`Dining, Bar 27 Window*C f 1,=80.0 -0.440 NFRC, X0.24 NFP -,00 New Fleetwood-Norwood307O'- Zone'3-Living,,Dining, Bar 28 Window 24.0 0.320 NFRC 0.27 RC 270 New Sierra Pacific Windows - Fix .L Zone 3 - Living, Dining, Bar 29 Window 54.0 0.330 NFRC 0 C New Sierra Pacific Windows - Fr Dr. Zone 3 - Living, Dining, Bar 30 Window 80.0 0.440 NFRC 4 N C - 0 New Fleetwood -Norwood 3070 Zone 3 - Living, Dining, Bar 31 Window 24.0 0.320 NFRC f^G2< 7 iJJ 270 New Sierra Pacific Windows - Fix .L Zone 3 - Living, Dining, Bar 32 Window 48.0 0.330 NFRC 0.. FRC 180 New Sierra Pacific Windows - Fr Dr.q Zone 4 - Fam,Kit,Off,Bath,LaU (1) LI -Factor Type: 116-A = ble fro �iI ards, NFRC = Labeled Value 2 SHGC Type: 116-B etauft T from 't .dards, NFRC = Labeled Value EXTERIOR SHADING DETAIMS ID Exterior Shade T e S WW dow Wd Ove hang Left Fin Ri ht Fin Len H t LExt RExt Dist Len H t Dist I Len H t 17 Bug Screen 0.76 18 Bug Screen 76 8.0 6.0 10.0 0.1 10.0 10.0 19 Bug Screen 6 10.0 24.0 14.0 0.5 11.0 11.0 1.0 9.8 0 11.0 4.5 0 20 Bug ScreeV 0.76 7.3 10.0 14.0 0.5 11.0 11.0 21 Bug S 'en 0.76 22 Bu • n 0.76 23 Bug SEft log0.76 24 Bug Screen4%wdr 0.76 25 Buq Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 9.0 6.0 5.5 0.1 2.Q 30 Bug Screen 0.76 10.0 8.0 5.3 4.7 0.'7 3.5 U;0 .5 - 5 0 31 Bug Screen 0.76 3.3 8.0 5.3 0.7 0. 3J5 t •_ S " 32 Bu Screen 0.76 8.0 6.0 10.0 0.1 10.'0 10.0, AFJ OR CO' OVED IPage Ener Pro 5.1 by EnergySoft User Number: 5732 RunCode: 2013-04-30704:29:57 ID: 1 043013 6 of 8 I DATE Reg: 213-N0025645A-000000000-0000 Registration Date/Time: 2013/04/30 07:4 09-- HER6�Yrovider_ Ca_10ERT , Inc Electronically Filed by Santiago Lopez-Ocampo and Authenticated at CalCERTS.com - 4/30/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name CLARK & SOLIS DEVELOPMENT LLC Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1413012013 OPAQUE SURFACE DETAILS Surface U- -Type Area Factor Insulation Joint Appendix CavityTExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,302 0.025 R-38 0 0 New 4.2.1-A21 Zone 4 - Fam, Kit, Off, Bath, AO Tw WA FENESTRATION SURFACE DETAILS IV ID Type Area LI -Factor' SH C' Azm Status*,Glazing Location/Comments 33 Window 20.0 0.320 NFRC 0.27 NFRC 90 Newas , ific Window Fix Ic Zone 4 - Fam,Kit, Off, Bath, Lau 34 Window 48.0 0.330 NFRC 0.26 NFRC 90 New Terra Pacific Wind s - Fr Dr.1 Zone 4 - Fam, Kit, Off, Bath, Lau, 35 Window 20.0 0.320 NFRC 0.27 NFRC 90 New ierra Pacific lndows - Fix Ic Zone 4 - Fam, Kit, Off, Bath, Lau 36 Window 4.0 0.320 NFRC 0.27 NFRC 270 Ne rra Pacific tndows - Fix . Lc Zone 4 - Fam, Kit, Off, Bath, Lau 37 Window_- ,,,,,, .,4.0 0.320 NFRC ,0:27, NFRC____270 _.,�, ,Stoftendows - Fix -..Lc Zone 4 - Fam, Kit, Off, Bath, Lau 38 Window'\,'4.0 0.320 NFRC,-, -,-0.27 NFRC 27 , Nk, ", Sierra Pacific Windows'- Fix :L Zone 4 - Fam, Kit, Off, Bath, Lau, 39 Window "26.0 0.320 NFRC 0.31 NFRC 2M Ne Sierra Pacific Windows - Cas 1 Zone 4 - Fam, Kit, Off, Bath, Lau, 40 Window 23.0 -'0.320 NFRC 0.31 NFRC 70 New a Pacific Windows, Cas . Zone"4 - Fam,Kit, Off,Bath, Lau, 41 Window 15.0 1 0.340 NFRC 0.25 NFRC r 0 New terra Pacific Windows - DH. Lo Zone 4 - Fam, Kit, Off, Bath, Lau 42 Window J15.0; : 0.340 NFRC 0.25NFR 70 New Sierra Pacific Windows DH. Lo Zone 4 - Fam,Kit,Off Bath, Lau 43 Window&= ! ', 24.0' 0.330 NFRC -- 0.26 NFP 10 New Sierra'Pacific Windows - Fi Dr. Zone;4 - Fam;Kit Off, Bath, Lau 44 Window 7.0 0.340 NFRC 0.25 RC NK 90 New Sierra Pacific Windows - DH. Lo Zone 4 - Fam, Kit, Off, Bath, Lau 45 Window 7.0 0.340 NFRC 0'* . CNew Sierra Pacific Windows - DH. Lo Zone 4 - Fam, Kit, Off, Bath, Lau 46 Window 6.01 0.340 1 NFRC dM5 WC 060 New Sierra Pacific Windows - DH. Lo Zone 4 - Fam, Kit, Off, Bath, Lau 47Window 1 6.01 0.340 1 NFRC 5 �F,p 0 New Sierra Pacific Windows - DH. Lo Zone 4 - Fam, Kit, Off, Bath, Lau 48Window 1 96.01 0. 4401 NFRC 0.2< r4FRC 270 New Fleetwood -Norwood 3070 Zone 4 - Fam,Kit, Off, Bath, Lau (1) U -Factor Type: 2 SHGC Type: 116-A = u ble fro t ards, NFRC = Labeled Value 116-B efault T from : , ndards, NFRC =Labeled Value EXTERIOR SHADING DETAI1 S ID Exterior Shade T Wt dow SH'Cro,_ Wd Overhang Left Fin Right Fin Len H t LExt I RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 876 35 Bug Screen 6 36 Bug ScreeV 0.76 37 Bug S- en 0.76 38 Bu Qn 0.76 39 Bug SEL7% 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Buq Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 I 1 t-- 45 Bug Screen 0.76 LJA Q IIN 46 Bug Screen 0.76 q G & F A PIPT 47 Bug Screen 0.76 ' 48 Bug Screen 0.76 FUR CONSTRUCTION LJ Ener Pro 5.1 6 Ene Soft User Number: 5732 RunCode: 2013-04-30T0 : ID: 1 043013 Reg: 213-N0025645A-000000000-0000 Registration Date/Time: 2013/04//3007:41.09 HERS Providen z atL Inc ' . . Electronically Filed by Santiago Lopez-Ocampo and Authenticated at CalCERTS.com - 4/30/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name CLARK & SOLIS DEVELOPMENT LLC Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1413012013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built HVAC System - Zone 1 Bedrooms 1,997 15,976 HVAC System - Zone 2 Bedroom 2 573 5,157 HVAC System - Zone 3 Living, Dining, Bar 1,196 20,093 HVAC System - Zone 4 Fam-Kit-Off-Laundry-Casita 1,761 15,849 Totals 1 5,5271 4 1 01 1 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Coolindrype Min. EV Thermostat Type Status HVAC System - Zone 1 1 Central Furnace 80% AFUE Split Air Con1tioner 1 P SEER Setback New HVAC System - Zone 2 1 Central Furnace 80% AFUE Split 'r Con rt • er JfO SEER Setback New HVAC System - Zone 3 1 Central Furnace 80% AFUE Air Condition 13.0 SEER Setback New HVAC System - Zone 4 1 Central Furnace 80% AFUEIlRplitConditioner 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Ducts Co q Duct Location R -Value Tested? Status HVAC System - Zone 1 Ducted DuctedkdAttic, Ceiling Ins, vented 8.0 m New HVAC System - Zone 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC System - Zone 3 Ducted l3ucted Attic, Ceiling Ins, vented 8.0 El New HVAC System - Zone 4 1 Ducted D ted Attic, Ceiling Ins, vented 8.01 D 1 New WATER HEATING SYSTEMEJ It S stem Name a Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status A O Smith Water P • ucts Lara as All Pipes Ins 80,000 74 0.78 0.00% n/a New MULTI- A tLY WATIkIR HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 0 i� a — TS� It7m NSF L nth IG f er Insul. Thick. Qty. HP Plenum Outside Buried ❑DI ''` ❑ t ❑ J� r ❑ S DAT Ener Pro 5.1 by Ener Soft User Number: 5732 RunCode: 2013-04-30 57 Pa e 8 of 8 Reg: 213-N0025645A-000000000-0000 Registration Date/Time: 2013/04/30 07:41:09 HERS Provider: CalCERTS, Inc A 0 0 Sladden Engineering 45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 800 E. Florida Avenue, Hemet, CA 92543 (951) 766-8777 Fax (951) 766-8778 August 14, 2013 Project No. 544-13192 13-08-396 Clark &Solis Development 48476 Stillwater Drive La Quinta, California 92253 /11A�0 Project: Proposed Custom Residence OC,1172013 Lot 235 - The Hideaway oMC OF V 1 7 2413 La Quinta, California N Subject: Geotechnical Update F Q(/I'VTq CQPMFNr Ref: Geotechnical Engineering Report prepared by Earth Systems Southwest (ESSW) dated September 22, 2000; File No. 07117-10, Report No. 00-09-772 Report of Testing and Observation During Rough Grading prepared by ESS dated August 28, 2002; File No. 07117-11, Report No. 01-07-718 Report of Testing and Observatio in Rough Grading prepared by Sladden Engineering dated October 12, 2003; ro''e�'�VN0. b$4c - -647 QUINT As requested, we have reviewed the above re erB ced�-gelotl l ca14EQoyrtf j3 e ate to the design and construction of the proposed Gust m resitienccee. e rr s tdentt ed as Lot 235 within the Hideaway Golf Club develop ent irtcth`9-1Q 0N- i/ '`nC�aliforni . It is our understanding that the proposed residence w 11 be a rel lively ligh lg It -fra structure supported by conventional shallow spread fo, tt , pipr Isla _ on grade. The subject lot was previously graded during the rough gradingo e �. ect site and was subsequently regraded. The rough grading included over -excavation of the native surface soil along with the placement of engineered fill soil to construct the building pads. The regrading included processing the surface soil along with minor cuts and fills to construct the individual building pads to the current configurations. Some additional over -excavation was performed in areas where the building envelopes were reconfigured. The most recent site grading is summarized in the referenced Report of Testing and Observations During Rough Grading prepared by Sladden Engineering along with the compaction test results. The referenced reports include recommendations pertaining to the construction of residential structure foundations. Based upon our review of the referenced reports, it is our opinion that the structural values included in the referenced grading report prepared by Sladden Engineering remain applicable for the design and construction of the proposed residential structure foundations. August 14, 2013 -2- Project No. 544-13192 13-08-396 Because the lot has been previously rough graded, the remedial grading required at this time should be minimal provided that the building falls within the previously established building envelope. The building area should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted to a minimum of 90 percent relative compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. The allowable bearing pressures recommended in the referenced grading report prepared by Sladden Engineering remain applicable. Conventional shallow spread footings should be bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be utilized if desired. The maximum allowable bearing pressure should be 3000 psf. The recommended allowable bearing pressures may be increased by one-third for wind and seismic loading. Lateral forces may be resisted by friction along the base of the foundations and passive resistance along the sides of the footings. A friction coefficient of 0.50 times the normal dead load forces is recommended for use in design. Passive resistance may be estimated using an equivalent fluid weight of 300 pcf. If used in combination with the passive resistance, the frictional resistance should be reduced by one third to 0.33 times the normal dead load forces. The bearing soil is non -expansive and falls within the "very low" expansion category in accordance with 2010 California Building Code (CBC) classification criteria. Slab thickness and reinforcement should be determined by the structural engineer. We recommend a minimum floor slab thickness of 4.0 inches. All slab reinforcement should be supported on concrete chairs to ensure that reinforcement is placed at slab mid -height. Slabs with moisture sensitive surfaces should be underlain with a moisture vapor retarder consisting of a polyvinyl chloride membrane such as 10 -mil Visqueen, or equivalent. All laps within the membrane should be sealed and at least 2 inches of clean sand should be placed over the membrane to promote uniform curing of the concrete. To reduce the potential for punctures, the membrane should be placed on a pad surface that has been graded smooth without any sharp protrusions. If a smooth surface can not be achieved by grading, consideration should be given to placing a 1 -inch thick leveling course of sand across the pad surface prior to placement of the membrane. Based on our field observations and understanding of local geologic conditions, the soil profile type judged applicable to this site is So, generally described as stiff soil. The following presents additional coefficients and factors relevant to seismic mitigation for new construction based upon the 2010 California Building Code (CBC). R/nddepy F.- minpi-.rhy!7 August 14, 2013 -3- Project No. 544-13192 13-08-396 The seismic design category for a structure may be determined in accordance with Section 1613 of the 2010 CBC or ASCE7. According to the 2010 CBC, Site Class D may be used to estimate design seismic loading for the proposed structures. The 2010 CBC Seismic Design Parameters are summarized below. Occupancy Category (Table 1604.5): II Site Class (Table 1613.5.2): D Ss (Figure 1613.5.1):1.50g S1 (Figure 1613.5.1): 0.608 Fa (Table 1613.5.3(1)):1.0 Fv (Table 1613.5.3(2)):1.5 Sms (Equation 16-36 (Fa X Ss)): 1.50g Sm1(Equation 16-37 (Fv X Sl)): 0.90g SDS (Equation 16-38 (2/3 X SMS)): 1.008 SD1(Equation 16-39 12/3 X Sml)): 0.608 Seismic Design Category: D If you have questions regarding this letter or the referenced reports, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERING �r BRETT L. Brett L. Anderson No. cam' 3os Principal Engineer EXP. 9/30/14 CIVIL ENGINEERING SER/gvm Copies: 4/Clark & Solis Development NkiddP.)t Fwrinnnri»n LA QUINTA Please verify that soils reports contain all of the above information. In addition, to assure continuity between'the investigation/reporting stage and the execution stage, please use the following checklist to verify that the conclusions and recommendations in the report cover all the required -elements. Only then- can we be assured that the construction documents address all of the site soil conditions. La Quints Geotechnical Report Checklist Does the "Conclusions and Recommendations" section of the report address each of the following criteria? "Address" means: (a) the criterion is considered significant and mitigation measure(s) noted, or; (b) the criterion is considered insignificant and explicitly so stated. Yes leo Criterion ❑ Foundation criteria based upon bearing capacity of natural or compacted soil. ❑ Foundation criteria to mitigate the effects of expansive soils. ® Foundation criteria based upon bearing capacity -of natural or --compacted soil. ❑ Foundation criteria to mitigate the effects of liquefaction. ❑ Foundation criteria. to mitigate the effects of seismically Induced differential settlement. ❑ ❑ Foundation criteria to mitigate the effects of long-term differential settlement. ® ❑ Foundation criteria to mitigate the effects of varying soil strength. 1 ® Foundation criteria to mitigate expected total and differential settlement. Any "No" answers to the -above checklist should be noted as specific required cofrections.