Loading...
04-5080 (SFD)-N T44f - 4 44d�ra P.O. Box 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 APN: Application description Property Zoning . . . . . . Application valuation . . . Owner --------------------------------- MIKE KESSLER 53496 VIA PALACIO LA QUINTA, CA 92253 BUILDING PERMIT BUILDING & SAFETY DEPARTMENT (760)777-7012 FAX (760) 777-7011 INSPECTION REQUESTS (760) 777-7153 Date 12/23/04 53496 VIA PALACIO 772-560-058- - - DWELLING - SINGLE FAMILY DETACHED LOW DENSITY RESIDENTIAL 483358 Contractor A & M CONSTRUCTION P.O. BOX 366 LA QUINTA, CA 92253 (760)564-4832 WCC: STATE FUND WC: 0460009232 01/01/05 CSLB: 746198 02/28/06 CCC: B -C10 P.O. BOX 1504 VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: Date: / - �/• �s Applicant: Architect or Engi eer NF Applicant's Mailing Address:' c� hit�or� gine�,lu tAddr 1 c. No.: 1 ,9 d Ll BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (comZr ncing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. �e License Class —1 �7t� icense No. l 1 6 l v OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): ( j I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one'year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (, I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. K I have and will maintain workers' compens ion insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issu y rkers' ensatio�surance carrier and lnum�,e�(� mer f/w� (� / Policy Number O If Rio , �— 71 3; —I certify that, tAhe performance of th work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, d agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, 1 shall forthwith comply with those provi ns. ,,-V-ate t "Z Ap t WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address A APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a (esult of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes n and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit toCance tion. I certify that I have read this application and state that the above info tion is correct I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county t e r upon the above-mentlbned gg_qy for inspection purposes. Dto/Zl'© 5j Signature (Applicant or Agent): l Application Number . . . . . 04-00005080 ----------------------------------------------------------------------------- ------ Structure Information SFD ----- Construction Type TYPE V - NON RATED Occupancy Type DWELLG/LODGING/CONG <=10 Flood Zone . . . . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC # BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG 927.00- PATIO 27.00PATIO SQ FTG 1150.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 4602.00 2ND FLOOR SQUARE FOOTAGE 966.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc Permit Fee 1983.50 Plan Check Fee 1289.28 Issue Date . . . . Valuation . . . . 483358 Qty Unit Charge Per Extension BASE FEE 639.50 384.00 3.5000 THOU BLDG 100,001-500,000 1344.00 -------------------------------------------------------=-------------------- Permit ... . . . . Additional desc . . Permit Fee . . . . Issue Date ELEC-NEW RESIDENTIAL 243.42 Plan Check Fee . . 60.86 Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 5568.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 194.88 927.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 18.54 1.00 ---------------------------------------------------------------------------- 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . . . . GRADING PERMIT Additional desc Permit Fee . . . . 15.00 Plan -Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL Additional desc Permit Fee . . . . 145.50 Plan Check Fee 36.38 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36.00 4.00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 8.00 6.5000 EA MECH VENT FAN 52.00 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . . . . PLUMBING Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total Charged Paid 2595.92 .00 1438.65 250.00 3290.65 .00 7325.22 250.00 Credited Due .00 2595.92 .00 Application Number . . . . . 04-00005080 3290.65 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING Additional desc Permit Fee . . . . 208.50 Plan Check Fee 52.13 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 21.00 6.0000 EA PLB FIXTURE 126.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.50.00 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3..00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 14.00 ..7500 EA PLB GAS PIPE >=5 10.50 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 5568 sq. ft. sfd this permit does not include pool & spa block walls or driveway approach. 12/23/04 10:37:04 A M jjohnson ---------------------------------------------------------------------------- Other Fees . . . . . . . . ART IN PUBLIC PLACES -RES 708.39 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 128.93 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) _ RES 48.33 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total Charged Paid 2595.92 .00 1438.65 250.00 3290.65 .00 7325.22 250.00 Credited Due .00 2595.92 .00 1188.65 .00 3290.65 .00 7075.22 S3 -gg6 V14— P4,c.4r�O cv P.O. BOX 1504 APPLICATION ONLY Building78-495 CALLE TAMPICO Addresses T" 2�LA QUINTA, CALIFORNIA 92253 Owner SpA I,. I��J �w v I mailing Address U.& BUILDING: TYPE �CONST �—P. OCC. GR A.P. Number 7 e j 2 —5b 7,9�79""1-2 72 ILegal Description Addres '"%S O`7o CADIZ CityL, ZI 'ZZrj aj Tel. 56q fy�*z State Lic. 114619$ 11619 $ City /— & Classif. —I Lic. # �p Z 1� Arch., En Designer FA Add Ss Tel. I 'fPb-"7-Z7 Lic. # -CENSED CONTRACTOR'S DECLARATION I hereby affirm thatJIlicensed undo(provisions of Chapter 9 (commencing with Section 7000) of Division 3 oBusiness and Professions Code, and my license is in full force and effect. 10 — OWNER -BUILDER DECLARATION I hereby aff' that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement chat he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the allegeo exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred doPars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or Im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure or a certificate of Worker's Compensation Insurance, or a certified copy er of (Sec. 800, abor Code. Policy No. Company110 ❑ Copy is filed with the city. O Certified copy is hereby fu hed. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed it the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT If, alter making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT Project Description S' FD ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE— Issued by: Validated by:— Validation: YELLOW = APPLICANT INSPECTOR Date Permit PINK = FINANCE Sq. Ft. Size No. -v— No. Dw. Stories Units New Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading t✓ - t! r Driveway Enc. WHY Infrastructure •.. _ . Ft� �;. Quoit T TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE— Issued by: Validated by:— Validation: YELLOW = APPLICANT INSPECTOR Date Permit PINK = FINANCE Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVELONEAMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE* RFr..FTPT• CHECK k• INITIALS, CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: The Residence{is at," Tlie,Hjdeaway Date: January 21, 2005 Owner's Name: Mike Kessler Phone No. Project Address: 53-496 Via Palacio Project Description: 1 SFD APN: 772-560-058 La Quinta, CA Tract #: Type of Development: Residential XX! Commercial Lot #'s: Industrial Total Square Feet of Building Area: 5568.282 Certification of Applicant/Owners: The person signing certifie that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorize to sign on behalf of the owner/developer. Dated: January 21, 2005 Signature: *********************************************************************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project 17620 65995 Approval Note: Number of Sq.Ft. 5568.282 Amount per Sq.Ft. $ 2.68 Amount Collected $ 14,923.00 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services Agreement Existing Not Subject to Fee Prior to 1/1/87 Requirement Certificate issued by: Elvira Mattson, Office Technician Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. 'Vx:.mydoe i(Ieeleescertiiieate arcompliance i")rm uibles"170 USI..doc 1/16/03 T 0 Certificate of Occupancy T4&f 4 4QKMrw Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time' of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 53-496 Via Palacio Use classification: S.F.D. Occupancy Group: R-3 Owner of Building: MIKE KESSLER Building Officia Type of Construction: V -N IN A CONSP Building Permit No.: 04-5080 Land Use Zone: R -L Address: P.O. BOX 366 City, ST, ZIP: LA QUINTA CA 92253 By: G. SHOWALTER Date: 02/06/06 TITLE 24 REPORT Title 24 Report for: A & M Builders Lot 234 - Hideaway La Quinta, CA Project Designer: CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR COff NS RUCTION DAT l kq g a Report Prepared By: Joan D. Hacker Insu-form, Inc. 68-255 Corta Road Cathedral City, CA 92234 (760) 324-2046 Job Number: Date: 10/5/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number. User Number. 2655 soal . C. C A n� ,...� ...� /(@Pq, tam �- TABLE OF CONTENTS Cover Page Table of Contents 2 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R A & M Builders 10/5/2004 _ Project Title Date Lot 234 - Hideaway La Quinta Project Address Building Permit # Insu-form Inc. (760) 324-2046 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check I Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 5,568 ft2 Average Ceiling Height: 10.6 ft Total Conditioned Slab Area: 4,602 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (West) 270 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 2 ❑ Raised Floor Component Const. Frame Assembly Location/Comments Tvpe U -Value (attic, garage, typical, etc. R-19 Wall (1.19.24.16) Wood 0.065 Exterior Wall R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Solid Wood Door None 0.387 Exterior Door CCIUCCT0AT1nM Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front (West) 21.0 0.55 0.45 Bug ScreenX❑ ❑ ❑ X❑ Front (West) 179.8 0.62 0.45 Bug ScreenX❑ ❑ ❑ X❑ Rear (East) 68.6 0.55 0.45 Bug Screen X❑ ❑ ❑ X❑ Rear (East) 226.6 0.62 0.45 Bug Screen X❑ ❑ ❑ X❑ Right (South) 54.7 0.62 0.45 Bug Screen X❑ ❑ ❑ X❑ Left (North) 123.7 0.62 0.45 Bug Screen X❑ ❑ ❑ X❑ Rear (East) 144.0 0.68 0.45 Bug Screen X❑ ❑ ❑ R Right (South) 45.0 0.55 0.45 Bug Screen X❑ ❑ ❑ Z ❑ -❑ ❑ ❑ 0 E 1:1 F1 El El ❑❑ El El El Run Initiation Time: 10105/04118:50:00 Run Code: 109 27400 Ener Pro 3.1 ByEnergySoft User Number. 2655 Job Number. Pa e:3 of 18 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R A & M Builders 10/5/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnarp 80% AFUE Ducts in Attic 42 Setback Second Floor Central Furnace 80% AFUE Ducts in Attic 42 Sethack Zone 1 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Casita Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 Sethack Sernnd Flnnr Split Air Conditioner 12 n SFFR Ducts in Attic 42 Sethack Zone 1 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Casita WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A_O. SMITH FPS -50-224 Small Gas Standard 2 43,000 50_ 0.62 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owpeer(per B siness & Professions Code) Documentation Author Name: /vim ��'f � Name: Joan D. Hacker Title/Firm: Title/Firm: Insu-form, Inc. Address: pAddress: 68-255 Corta Road t X 92J ( 2 11:2-53 Cathedral City, CA 92234 Telephone: ® gr & q 4� Telephone: (760) 324-2046 Lic. #: uo w (signature) (date) (sign tur) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature/stamp) (date) Run Initiation Times 10/0510418.50.00 Run Code: 1097027400 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. PageA of 18 a TI Certificate of Compliance: Residential (Addendum) CF -1 R A & M Builders 10/5/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies Jaseu on Elie auequacy or ine special Jusuncauon ana oocumemation suomiaeo. Plan I Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 980 sqft Covered Slab Floor, 3.50" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 3081 sqft Exposed Slab Floor, 3.50" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 541 sqft Covered Slab Floor, 3.50" thick at Casita HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS proviaer. i ne mr-Kb rater must aocument the tiew verincation ana aiagnostic testing of tnese measures on a torm CF -6R. Plan Field The HVAC System "Second Floor" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Zone 1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performe by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Casita" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performe by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 1010510418:50:00 Run Code: 1097027400 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:5 of 18 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures F '§150(a): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. '§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 pemvnch. a§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ Gas Appliances Gas Logs. §150(e): Installation of Fireplaces, Decorative and 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures F §110 HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ®§150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. FV §150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ § 1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:6 of 18 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. (DESCRIPTION instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER I ENFORCEMENTI Space Conditioning, Water Heating and Plumbing System Measures: (continued) 1 a I150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in i j conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system I that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or autcmatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not Iimifed to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36' of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36' of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. F[A] §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Coot Roof material meet specified criteria Lighting Measures ® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. IA-] §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number. 2655 Job Number. Page:7 of 18 Computer Method Summary (Part 1 of 3) C -2R A&_ M B_uildPrs _ 10/5/2004 Project Title Date _ _Lot 234 - Hideawava_Quinte _ Project Address Building Permit # 1n-qu-form, Inc (760 32) 4=2046 Plan Check/Date Documentation Author Telephone Computer Performance 15 1 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 1.87 1.93 -0.06 Space Cooling 27.84 26.49 1.35 Domestic Hot Water 5.12 5.42 -0.30 Totals 34.83 33.84 0.99 Percent Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name 2.8% 5,568 ft2 Floor Construction Type: ❑ Raised Floor OX Slab Floor Single Fam Detached (West) 270 deg Total Fenestration Area: 15.5% 1.00 Total Conditioned Volume: 58,775 ft 3 2 Total Conditioned Slab Area: 4,602 ft 2 # of Floor Area Volume Units Zone Type S - .ngc_nd Flpor _ 966 A 694 017 rnnditinnQ(i_ 7one 14.06 44,671 0.73 Conditioned casita 541 5.410 0.10 Conditioned Thermostat Type Sgthack Setback Sethack Vent Hgt. Area —8 n/:; 8 _— /a 8 n/a Solar OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y / N Form 3 Reference Location / Comments Computer Method Summary (Part 2 of 3) C -2R A & M Builders 10/6/2004 Project rdle Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Tvpe Area Factor SHGC Azm. Tilt Comments _1_ Window Front oNest) 21.0 0.550 0.45 270 90 Milgard Windows Second Floor 2 Window Front (West) 19.3 0.620 0.45 270 90 Milaard Windows Second Floor 3 Window Rear (East) 24.0 0.550 0.45 90 90 Milgard Windows Second Floor 4 Window Rear (East) 27.0 0.620 0.45 90 90 Milgard Windows Second Floor 5 Ri Window ght (South) 15.8 0.620 0.45 180 90 Milgard Windows Second Floor 6 Window Right (South) 9.0 0.620 0.45 180 90 Milgard Windows Second Floor .7_ Window Front (West) 15.5 0.620 0.45 270 90 Milgard Windows Zone 1 8 Window Front (West) 10.3 0.620 0.45 270 90 Milgard Windows Zone 1 6 Window Front (West) 23.4 0.620 0.45 270 90 Milgard Windows Zane 1 1Q Window Front (West) 72.0 0.620 0.45 270 90 Milgard Windows Zone 1 11 Window Left (North) 36.0 0.620 0.45 0 90 Milgard Windows Zone 1 12 Window Left (North) 3.3 0.620 0.45 0 90 Miluard Windows Zone 1 ja Window Left (North) 232 0.620 0.45 0 90 Milgard Windows Zone 1 14 Window Left (North) 3.3 0.620 0.45 0 90 Milaard Windows Zone 1 15 Window Left (North) 48.0 0.620 0.45 0 90 Milgard Windows Zone 1 16 Window Rear (East) 63.0 0.620 0.45 90 90 Milgard Windows Zone 1 17 Window Rear (East) 24.0 0.550 0.45 90 90 Milgard Windows Zone 1 18 Window Rear (East) 144.0 0.680 0.45 90 90 Milgard Windows Zone 1 _11 Window Rear (fit) 32.0 0.620 0.45 90 90 Milgard Windows Zone 1 20 Window Rear (East) 84.1 0.620 0.45 90 90 Milgard Windows Zone 1 21 Window Rear (East) 17.2 0.620 0.45 90 90 Milgard Windows Zone 1 2Z Window Right (South) 24.0 0.550 0.45 180 90 Milgard Windows Zone 1 23 Window Right (South) 6.0 0.620 0.45 180 90 Milgard Windows Zone 1 24 Window Right (South) 20.6 0.620 0.45 180 90 Milgard Windows Zone 1 25 Window Front (West) 3.3 0.620 0.45 270 90 Mildard Windows Casita 26 Window Front (West) 36.0 0.620 0.45 270 90 Milgard Windows Casita 27 Window Left (North) 3.3 0.620 0.45 0 90 Milgard Windows Casfta 28 Window Left (North) 3.3 0.620 0.45 0 90 Milgard Windows Casita 29 Window Left (North) 3.3 0.620 0.45 0 90 Milgard Windows Casita INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEd. REA Dist. Len. Hgt. Dist. Len. Hgt 1 Bug Screen 0.76 7.0 3.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 5.0 2.0 2.0 0.1 2.0 2.0 _ 3 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 _ 4 Bug Screen 0.76 3.5 3.0 2.0 0.1 2.0 2.0 _ 5 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 _ 6 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 _ 7 Bug Screen 0.76 5.5 3.0 2.0 0.1 2.0 2.0 _ 8 Bug Screen 0.76 5.5 2.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 1.7 1.2 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 6.0 12.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 7.2 6.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 1.7 1.5 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 1.7 1.5 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 5.5 4.0 40.0 0.1 40.0 40.0 _ 16 Bug Screen 0.76 8.3 6.5 2.0 0.1 2.0 2.0 17 Bug Screen 0.76 8.0 3.4 2.0 0.1 2.0 2.0 _ 18 Bug Screen 0.76 8.0 18.0 12.0 0.1 12.0 12.0 19 Bug Screen 0.76 6.8 4.5 14.0 0.1 14.0 14.0 20 Bug Screen 0.76 5.5 4.5 2.0 0.1 2.0 2.0 21 Bug Screen 0.76 5.5 3.5 2.0 0.1 2.0 2.0 22 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 _ 23 Bug Screen 0.76 2.0 1.7 2.0 0.1 2.0 2.0 24 Bug Screen 0.76 5.5 4.0 2.0 0.1 2.0 2.0 25 Bug Screen 0.76 1.7 1.4 2.0 0.1 2.0 2.0 26 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 27 Bug Screen 0.76 1.7 1.4 2.0 0.1 2.0 2.0 _ 28 Bug Screen 0.76 1.7 1.4 2.0 0.1 2.0 2.0 29 Bug Screen 0.76 2.0 1.8 2.0 0.1 2.0 2.0 EnerovPro 3.1 By EnergvSoft User Number: 2655 Job Number. Page:9 of 18 1 Computer Method Summary (Part 2 of 3) C-2R A & M Builders 10/6/2004 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments M Window Rear (East) 3.3 0-620 0.45 90 90 Milgard Windows Casita 31 Window Rear (East) 20.6 0.550 0.45 90 90 Milgard Windows Casita 32 Window Right (South) 3.3 0.620 0.45 180 90 Milgard Windows Casita 33 Window Right (South) 21.0 0.550 0.45 180 90 Milgard Windows Casita INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA. REM. Dist. Len. Hgt. Dist Len. Hgt. 30 Bug Screen 0.76 1.7 1.4 2.0 0.1 2.0 2.0 31 Bug Screen 0.76 5.1 5.0 2.0 0.1 2.0 2.0 _ 32 Bug Screen 0.76 1.7 1.4 2.0 0.1 2.0 2.0 _ 33 Bug Screen 0.76 7.0 2.0 2.0 0.1 2 0 2.0 _ Run In' ' tion Time: 10/06/04 07:51:35 Run Code: 1097074295 3.1 By EnergySoft User Number. 2655 Job Number. Page: 10 of 18 Computer Method Summary Insulation (Part 3 of 3) C -2R A & M Builders Slab Perimeter _22 0.76 0.0 0 Zone 1 10/5/2004 Project Title Slab Perimeter 18 0.76 0.0 0 Casita Date THERMAL MASS FOR HIGH MASS DESIGN Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) Area Thick. Heat Comments Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments _C_onzete—Hpavtmeight 98n 15 78. 0.98 n/a —2 Zone 1 /,IS ab on Grade Concrete. Heavyweight 3.081 3_50 28 0_98 n/a 0 Zone 1 / Slab on Grade Concrete, Heay)weight 54 3.50 28 0.98 n/a 2 Casita / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor' R -Val. Depth Location / Comments Slab Perimeter _22 0.76 0.0 0 Zone 1 Slab Perimeter 78 0.76 0.0 --Q Zone 1 Slab Perimeter 18 0.76 0.0 0 Casita HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Second Floor Central Furnace 80%AFUE Ducts in Attic 4.2 Setback Zone 1 Central Furnace 80°o AFUE Ducts in Attic 4.2 Setback Casita Pipe Insul. Hydronic Piping Pipe System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Second Floor Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Zone 1 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Casita WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.O. SMITH FPS -50-224 Small Gas Standard 2— 43.000 50 0.62 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 1010510418:50:00 Run Code: 1097027400 EnemyPro 31 By EnemySoft User Number. 2655 Job Number: Page: 11 of 18 Computer Method Summary (Addendum) C -2R A & M Builders 10/5/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local s ._ ... ,..6 ,,.e...., A fftr. inns rtio nrionliacv of tha iuetificatinn_ and may reiect a building or desion that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field HIGH MASS Design(see C72R) - Verify Thermal Mass: 980 sqft Covered Slab Floor, 3.50" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 3081 sqft Exposed Slab Floor, 3.50" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 541 sqft Covered Slab Floor, 3.50" thick at Casita HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan I Field The HVAC System "Second Floor' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Zone 1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performe by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Casita" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performe by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Page: of 18 EneravPro 3.1 By EnemySoft User Number. 2655 Job Number. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE A & M Builders 10/5/2004 SYSTEM NAME FLOOR AREA Second Floor 966 Number of Systems COIL HTG. PEAK 11 Heating System Latent Output per System I 37,000 Total Output (Btuh) 37,000 Output (Btuh/sqft) 38.3 Cooling System Output per System 23,200 Total Output (Btuh) 23,200 Total Output (Tons) 1.9 Total Output (Btuh/sgft) 24.0 Total Output (sgftrTon) 499.7 Air System CFM per System 895 Airflow (cfm) 895 Airflow (cfrrdsgft) 0.93 Airflow (cfm/Ton) 462.9 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airs 26.0 of 69.7 of 69.7 of Outside Z 0 cfm 69.7 of :DOLING S 11.0 / 77.4 of I Outside 0 cfm 78.5/67.9 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 703 10,004 449 1451 5,886 0 500 zsa 0 0 0 0 0, 0 0 0 0 500 294 11,005 449 6=475 DP CO. 563AN024-A 13,729 7,981 37,000 Total Adjusted System Output I 13,7291 7,981 37,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am yam I emoeratures at Time of Heating Peak) 108.3 of Supply Fan Heating Coil 895 cfm Return Air Ducts its at Time of C( 78.5167.9 OF 78.5 / 67.8 OF 64.2 163.2 OF —w— -- I Supply Fan Cooling Coil 895 cfm User Number. 2655 Return Air Ducts Job Number. Supply Air Ducts 107.9 of ROOMS 70.0 of Supply Air Ducts . 64.7 / 63.4 of 59.5% R.H-. ROOMS 78.0 / 67.8 of 13 of 18 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME A & M Builders DATE 10/5/2004 SYSTEM NAME FLOOR AREA 4,061 Zone 1 0 INumber of Svstems 1 2111 Total Output (Btuh) 1 160,000 Output (Btuh/sgft) 1 39.4 Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfmisgft) Airflow (cfrn ron) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions 26.0 OF 0 Outside 0 cfm 69.3 OF 11.0 / 77.4 OF Outside Air 0 cfm 78.8/66.8 °F 3.1 120,000 10.0 29.5 406.1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I I COIL HTG. PEAK CFM I Sensible Latent I j CFM j Sensible 4,337 73,844 10,46 j 1,731 64,657 0 3,692 3,233 0 0 0 0 0 0 0 0 I 0 3,692 3,233 10,46. 71123 1 81,228 2,055 BDP CO. 563AN060-A 77,362 32,842 160,000 4,110 1.01 411.0 _ 0.0 Total Adjusted System OutputI 77.362 32,8421 160,000 (Adjusted for Peak Design Conditions) 0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Wmtrpam Temneratures at Time of Heatinq Peak) 69.3 of 69.3 of . 105,60F Supply Fan Heating Coil 4110 cfm y% Return Air Ducts 'I ROMETRICS (Airstream Temperatures at 78.8/66.8°F 78.8/66.7°F 0 61.3/60.2°F Supply Fan Cooling Coil 4110 cfm User Number. 2655 Retum Air Ducts Job Number. Supply Air Ducts 104.8 OF ROOMS 70.0 OF I Supply Air Ducts 62.1 / 60.5 of 55.2% R.H.ROOMS 78.0 / 66.5 OF 4of18 i HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE A & M Builders 10/5/2004 SYSTEM NAME FLOOR AREA Casita 541 Number of Total Output (Btuh) Output (Btuh/sgft) Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sqft) Total Output (sgftrron) Air System CFM per System Airflow (cfm) Airflow (cfmisgft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRIi r 37 37 1.9 42.9 279.8 26.0 of 69.7 of 69.7 OF 17 Outside Air 0 cfm 69.7 of 11.0 / 77.4 of 0 Outside 0 cfm 78.4/67.7 of SYSTEM Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensiblel Latent I I CFM I Sensible 493 7,193 252 142 5,769 0 360 i 288 0 OI 0 0 0 0 0 0 0 288 360 7,913 252, 6,346 895 895 BDP CO.563AN024-A 13.771 7,857 37,000 1.65 62.9 0.0 Total Adjusted System Output 13,77 7,857 37,000 (Adjusted for Peak Design Conditions) 0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 108.3 of Supply Fan Heating Coil 895 cfm Time k Return Air Ducts 'I 78.4 / 67.7 of _ 78.4/67.60F M 64.0 / 63.O of Supply Fan Cooling Coil 895 cfm Time of f% Return Air Ducts `i Supply Air Ducts 108.0 of ROOMS 70.0 of Supply Air Ducts 64.4 / 63.2 of 58.9% R.H. ROOMS 78.0 / 67.6 of EneravPro 3.1 By Energysoft User Number. 2655 Job Number. Page: 15 of 18 ROOM LOAD SUMMARY PROJECT NAME DATE A & M Builders 10/5/2004 SYSTEM NAME FLOOR AREA Second Floor 966 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Second Floor Second Floor 1 703 10,004 449 703 10,004 449 145 5,886 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page: 16 of 18 PAGE TOTAL 1 703 10,004 449 145 5,886 TOTAL 1 703 10,004 449 r 145 5,886 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page: 16 of 18 ROOM LOAD SUMMARY PROJECT NAME I DATE A & M Builders 10/5/2004 SYSTEM NAME FLOOR AREA Zone 1 _4 ,061 _ ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:17 of 18 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT 11 CFM SENSIBLE Zone 1 Zone 1 1 4,337 73,844 10,461 4,337 73,844 10,461 1,731 64,657 PAGE TOTAL 4,337 73,844 10,461 1,731 64,657 TOTAL 4,33773,844 10,461 1,731 64,657 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:17 of 18 ROOM LOAD SUMMARY PROJECT NAME DATE A & M Builders 10/5/2004 SYSTEM NAME FLOOR AREA Casita 541 ROOM LOAD SUMMARY ROOM COOLING PEAK r COIL COOLING PEAK 11 - COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM I SENSIBLE LATENT CFM SENSIBLE LATENT 11 CFM SENSIBLE Casita Casita 1 493 7,1931 252 493 7,193 252 142 5,769 PAGE TOTAL F 493 TOTAL 4937,193 F 7,193 252 142 5,769 252 142 5,769 EnergyPro 3.1 By EnergySoft UserNumber. 2655 Job Number. Page: 18 of 18 T44f 4 4 Q" P.O. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLS TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT (760)777-7012 FAX (760) 777-7011 To Customer: Permit #: Public Works Z' Fugitive Dust Control (PM -10) Plan Approval Instructions to Applicant: Public Works Department approval of a fugitive dust control plan is required prior to Building Permit issuance for the following project. Please: 1. Fill out the attached forms, then; 2. Submit this entire packet to the Public Works Department for review. If you need help completing the forms, contact the Public Works Department at 760-777-7075. The Public Works Department will review and, when approvable, forward the approved plan to the Building & Safety Department, approving the issuance of Building Permit(s). If the Public Works Department has questions or concerns, an attempt will be made to contact the person whose name and telephone number appear below. '_*1 - Project to be permitted: Project Street Address:. Applicant Contact & Telephone Number: L e'eo' /9-iDe,C P14t Cern Public Works Department Findings To: Greg Butler, Building & Safety Manager From John Freeland, Senior Engineer The Public Works Department has reviewed the attached Fugitive Dust Control Plan for the above-mentioned project and finds that: ❑ ...issuance of this Building Permit does not require Public Works Department approval. X...issuance of this Building Permit is approved by the Public Works Department. '1K •vi n Freeland, Senior Engineer ((bo joy Date 7 3z— Agreement The signature of the property owner (or authorized representative): ✓ Shall act as his/her acknowledgment of dust control requirements and their'- enforceability, pursuant to AQMD Rules 403 and 403.1. ✓ . Shall constitute an agreement to comply with all project conditions as identified in the approved dust control plan. The property owner (or authorized representative): ✓ Acknowledges that dust_ control is required 24 hours a day, 7 days a week, throughout the period' of project performance, .regardless of project size or status; ✓ Shall ensure that each and every contractor/subcontractor and all other persons associated with the project shall. be in continuous compliance with all requirements of the approved dust control plan; ✓ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust.control plan are necessary; ✓ Shall authorize representatives of the City/County to enter upon the above- mentioned property for inspection and/or abatement .purposes; and ✓ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control plan or any City/County-initiated abatement activities. PROPERTY' OWNER/ AUTHORIZED REPRESENTATIVE PRINTED NAME: TITLE 7 -- COMP ANY: SIGNATURE: DATE: Remember. - DUST CONTROL IS REQUIRED 24 HOURS A DAY, 7 DAYS A WEEK, REGARDLESS OF CONSTRUCTION. STATUS Section 1 Simplified Sample Site Plan 7S Z Existing Residentia S Equipment Staginj rea 4� . Vacant Land Remember.:. DUST CONTROL IS REQUIRED 74 HOURS A DAY, 7 DAYS A WEEK, REGARDLESS OF CONSTRUCTION STATUS Prevailing Wind 1 i ial (mont ap 'cation of chemi l tabilizer at 4 1 , conce rat or gre r to con of dust) f ,_te A" s/ Prevailing Wind b 0 Project Contact Information for (check one): Owner Nftees Authorized Representative* Environmental Observer* General Contractor Sub -Contractor Instructions: Name Please enter information below Title (if applicable) Company Name (if applicable) Mailing Address City i_ft-- 42U Lt-�Z A State Lfo-�T Zip Location Address �,. t4 -1 4 V1A- PA-CA610 City j& C2 U t D� �-1„fj� State Zip Primary Phone C &L T3 Z Fax 24 -Hour Access/Emergency Phone ^l 4 �Z Cellular Phone E-mail address Gc�-ti �Ik�GTCC'm Responsible for dust control during construction activities? ❑ T No Responsible for dust control during off -hours? E No r--r---.,---'.•• _ -..-%A %,vnLaVL 1V1 uir. piuivt;L, nlstner autnorizea representative is responsible for all dust control actions. Remember... DUST CONTROL IS REQUIRED 24 HOURS A DAY, 7 DAYS A WEEK, REGARDLESS OF CONSTRUCTION STATUS Dust Control Actions Project Name:_ Contractor Name: Instructions: Please complete this form for each phase of the construction project. Identify the phase by number (e.g., Phase 2 of 5) in the spaces provided below. Remember... DUST CONTROL IS REQUIRED 24 HOURS A DAY, 7 DAYS A WEEK, REGARDLESS OF CONSTRUCTION STATUS Instructions to Applicant: Please enter information below as requested. Clearing/Grubbing Project Phase (check): [) Mass Grading nish Grading �—f::-1`" t!:k$ e1A 1 '5-15`05; c__ 1 Construction Phase C] Other (specify: Anticipated Start Date: Z te;;._©� `1 I Anticipated Completion Date: , Number of Acres under Active Construction: _ �t � � S� << L 0—TV -5 Fr,> Detailed description of dust control actions implemented during this phase (should match information provided on site plan; use additional pages as necessary): Attach a Plot Plan for reference 1 ISS fl- F1 Ncs�'� ' I Y" F-5 Dom- c Y � m lz- Remember... DUST CONTROL IS REQUIRED 24 HOURS A DAY, 7 DAYS A WEEK, REGARDLESS OF CONSTRUCTION STATUS LTJ Plan Review Checklist Construction Phase Water applied continuously to all disturbed portions of the site by means of water truck/water pull is necessary -to maintain sufficient visible moisture on the soil surface reference, one 2,000 gallon water truck can treat approximately 4 acres of active construction ner hni ir e�rnru'."Sa'� rR;arm1VV �...s For Require the Applicant to ssecifir the number of watering vehicles available for dust control during the'construction phase and during off -hours as well as availability of back-up water trucks if the site experiences dust control problems. Wind fencing'is necessary between the site an upwind fencing and on-site wind fencingfor larger Off-site beingde 9 projects can also keep blowsand from posited onto the -site or traveling through the site. Block walls, if part of the final project, can replace wind fencing during the construction phase. Chemical dust suppressants are to be applied ata concentration of at least .20 to 1 to finish graded areas once final elevations have been reached. For areas that will remain inactive for longer periods, vegetation can be a cost-effective alternative to chemical stabilization. Wind fencing or other obstructions can keep the stabilized area free from future disturbances. Construction site accesses are to be improved with 1.S' gravel, maintained to a -depth of 4", with a width of at least 20', extending 100' into the project site.' Paving internal roadways can substitute for gravel. Internalroadway networks are to be paved as early as feasible in the construction phase. El Street sweeping of internal and/or external access roads will likely be required to control entrained road dust. Employee parking areas are to be treated with chemical dust suppressants at a mix ratio of no less than 4 to 1 and retreated on a monthly basis, or more frequently -if fugitive dust is observed. lf_intemal roadway is complete, employees are to be instructed to park on paved roads. Other (specify): Remember... DUST CONTROL IS REQUIRED 24 HOURS A DAY, 7 DAYS A WEEK, REGARDLESS OF CONSTRufTT ION STATUS r2lo 4 N -rte Suit Structural Engineering ti.. 106 E. Park Street, Ste. 206 McCall, ID 83638 (866)862-8148 (208) 634-8148 Fax (208) 634-4157 October 11, 2004 CITY OF LA QU NTA Foxworth Galbraith Truss C BUILDING &SAFETY PT. 10527 South Frontage APPROVED Yuma, AZ.85365 FOR CONSTR CTION Attn: Truss Designe DA 12?�—B Subject: Roof Truss Shop Drawings and Calculations Lot 234 at The Hideaways, .The Kessler Residence 53-496 Via Palacio La Quinta, CA Dear Truss Designer, The roof truss 'drawings by Foxworth Galbraith Truss Co. for the subject project were received by our office on October 1, 2004,. and is approved. The submittal has been reviewed for general. conformance to the design. concept of the project structural plans. The fabrication processes, techniques of construction, dimensions, and quantities are not a part of this review. Since the shop drawings were reviewed only for general conformance with the structural plans, unless variations. from the structural plans have been clearly indicated, we may not have listed them. Our review of these drawings does not relieve the truss engineer and the framing contractor from complying with the structural plans. Yours truly, SUMMIT STRUCTURAL ENGINEERING '�PpfilN ii � Benjamin Herbst, P.E. C0 t t io. 0:054193 M CC. �`1z pcp,1L3�C' BH c:\2004jobfiles\sv-226\226_truss l .doc Residential. Commercial. Industrial. Land Development