Loading...
12-0262 (SFD):?a P.O. BOX 1504 78-495 'CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 • KEA, BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number:, C i2-00000262 Property,Address: 53607' VIA PALACIO APN: 772 -560 -046 - Application descriptions DWELLING - SINGLE FAMILY DETACHED, Property Zoning: LOW DENSITY RESIDENTIAL. Application Valuation: 426088 Owner: JOHN KAVAYIOTIDIS', TRUST PO BOX 218 PEBBLE BEACH, CA 93953 VOICE 760) -i -r -7012' FAX ( 77-761 1, INSPECTIONS '(760) 777-7153 Date: 6/21/12 Contractor: Applicant: Architect or Engineer: JACOBS HOMES INC, PETER t p :i P.O. BOX 356 �3 3 LA QUINTA", CA'92247 4 (760) 777-9921 �Y�P Lid. No.: 799449 ¢q( . 1 ENSED NTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION " I hereby affirm under penalty of perjury t I am Ii sed under provisions, of Chapter 9 (commencing with - I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of DivisionL3 of the. Busin d ssionals Code, and my License is in full force and effect._ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: B License No.: 799449 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is ► issued. JEO tractor. - �: I have and will maintain workers' compensation insurance, as required. by Section 3700 of the Labor /// Code, for the performance of the work for which this permit is issued. My workers' compensation WNER-BUILDER DECLARATION - insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier STATE FUND Policy Number.. 7190003 92 " following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performa of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so to ecome su ect to the.workers' compensation laws of California, permit to file a signed statement that he or -she is licensed pursuant to the provisions of the Contractor's State and agree that, if I shou a me s to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with ,Section 7000) of Division 3 of the Business andProfessions Code) or 3700 of the Labor C I all f comply with those provisions. - " that he or she is exempt therefrom and thelbasis for the alleged exemption. Any violation of Section 7031.5 by �o��,� any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ' - ate: �� Iicant: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and - the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' C PENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or. improve for the purpose of sale.). - APPLICANT ACKNOWLEDGEMENT- I, as owner of the property,, am exclusivelycontracting with licensed contractors to construct the project (Sec.. ' IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of - conditions and restrictions set forth on this application. - - - property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed. 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). - - - whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_ 1 I am exempt under Sec. , B.&P.C. for this reason _ - the owner, and the applicant, each agrees to, and shalldefend, indemnify and hold harmless the City _ of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. - • Date: Owner: - - 2. Any permit issued as a result of this application.becomes null and void if work is not commenced within 180 days from date of issuance lbuildingctio essation of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit to cancellation. 'I herebyaffirm under penalty of perjury that there isa'construction lending agency for the performance of the - - I certify that I have read this application and state thanon is' rrect. I agree to comply with all work for which this permitis issued (Sec: 3097, Civ. C.). city and county ordinances and state laws relating too , an ere_by authorize representatives of this county to enter upon the above-mentioned prr es. Lender's Name: 2 �• - Date: " S' ature (Applicant or Agent): Lender's Address: ' LQPERMIT - Application Number 12-00000262 ------ Structure Information 4,756SF DWELLING/VB/RES-3/CL-A/13D fENG]----- Other struct info . . . . CODE EDITION 2010 # BEDROOMS 4.00 FIRE SPRINKLERS 13D GARAGE SQ FTG 1020.00. PATIO SQ FTG 827.00 NUMBER _.OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 4756.00 Permit. . . . BUILDING PERMIT . Additional-desc . Permit Fee 1784.00 Plan Check Fee 1159.60 Issue Date . . . . Valuation 426.088 L Expiration Date 12/18/12 Qty Unit Charge Per Extension BASE FEE 639.50 327.00 3.5000 ------------------------------------------------------------------------------- THOU BLDG 100,001-500,000 1144.50 Permit ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 216.86 Plan Check Fee . 54.22 Issue Date Valuation 0 Expiration•Date _ 12/18/12 Qty Unit Charge Per. Extension BASE FEE 15.00 4756.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 166.46 1020.00 ..0200 ELEC GARAGE OR NON-RESIDENTIAL 20.40 -1.00 15.0000 EA. ELEC TEMPORARY POWER POLE 15.00 -Permit GRADING PERMIT Additional desc . Permit Fee . . . . 15.00. Plan Check Fee _ .00 Issue Date . . . . Valuation . . 0 Expiration Date 12/18/12 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00. Permit MECHANICAL Additional desc . Permit Fee 173.50 Plan Check Fee 43.38 LQPERMIT'- Application Number 12-00000262 Permit MECHANICAL Issue Date Valuation 0 Expiration,Date 12/18/12 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 .9.0000 EA MECH FURNACE <=100K36.00. .1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 ` 4.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 66.00 7.00 6..5000 EA MECH VENT. FAN -45.50 1.00 6.5000 ------------------------------------------------------------------------------ EA MECH EXHAUST HOOD 6.50 Permit . . . PLUMBING Additional'desc . Permit Fee 203.25 Plan Check Fee 50.81 Issue Date . . . Valuation 0 Expiration Date 12/18/12 Qty Unit Charge Per. Extension ; BASE' FEE 15.00 21.00 6.0000 EA PLB FIXTURE 126.00 1.00- 15.0000 EA PLB BUILDING SEWER 15.00 2.00 .7.5000.EA PLB WATER HEATER/VENT 15..00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1-.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 3.00 .75`00 EA PLB GAS PIPE >=5 2.-25 1.00 15.00.00 EA PLB GAS METER 15.00 =-------------------------------------=------------------------------------- Special Notes and Comments . 4,756SF DWELLING/VB/RES-3/CLASS7A/13D [ENGINEERED] THIS.PERMIT DOES NOT.: INCLUDE POOL, SPA WATER FEATURES, OR BLOCK WALLS. 2010 CALIFORNIA BUILDING CODES. June 21; 2012 4:36:59 PM AORTEGA --------- --------- ----------------------------------------- Other`Fees . . . . . ;'-----=---------- . . . . ART IN PUBLIC PLACES-RES 565.22 BLDG STDS ADMIN (SB1473) 18.00 DIF COMMUNITY CENTERS-RES 74.00 DIF CIVIC CENTER -.RES 995.00 ENERGY REVIEW FEE 115.96 DIF"FIRE PROTECTION-RES 140.00 GRADING PLAN CHECK FEE 15.00 - DIF LIBRARIES - RES 355.00 MULTI-SPECIES (MSHCP) FEE 1254.00 DIF PARK MAINT FAC - RES 22.00 LQPERMIT ApplicationNumber._ 12-00000262 -----------------_------ Other Fees . . ----------- . . . . ---------------------------- DIF PARKS/REC = RES ------------- 892.00 STRONG MOTION (SMI) - RES 42.61 DIF STREET MAINT FAC -RES 67.00': DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid Credited ---------- Du® 'Permit-Fee-Total- .. 2392.61- .. - ,. 00 - - - - :00— `.2392 . 61 . Plan Check.Total 1308.0.1 750.00 .00 558.01 Other Fee Total 6485.79 00 00 6485:79 Grand Total 10186.41 7.50.00 .00' 9436.41. .LQPERMIT P.O. BOX 1504 Building 78-495 CALLE TAMPICO Address / V !�� LA QUINTA, CALIFORNIA 92253 Owner �, �. Address ��G `JUx 3 City Zip Tel. Contractor i i /fir V.0I A /4PAI -mss Address �� • '•r & Classif. # Arch., Engr., Designer Address Tel. City I Zip I State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property, who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason WORKER'S COMPENSATION DECLARATION hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT /;�--I?-CoC:�_- APPLICATION ONLY BUILDING: TYPE CONST. OCC. GRP. A.P. Number %72 'S(vC -1 4 ,- O Z G Ze, oJZ Legal Description Gas �roject Description Sq. Ft. No. / No. Dw. Size �' Stories / Units / New Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. 11n) AY n Plan Chk. Bal. Const. Mech. Electrical Plumbing OF S.M.I. -_ pgpr Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: ' BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW.= APPLICANT PINK = FINANCE Coachella Valley. Unified Sc 1 District �.. ' This Box For District Use Only :83-7-33 Avenue 55;: Thermal; CA 92274 DEVELOPER FEES PAID (760).398-5909 — Fax. (760) :398-1224 ARCA: � � �. � � �AMOUNT ' LEVEL ONE AMOUNT;: ... .. .. .. :LEVEL TWO AMOUNT: ... .. .. ... MITIGATION AMOUNT: . _ .. COMWIND.AMOUNT: ... .. DATE: ' RECEIPT: - CHECK #: INITIALS - CERTIFICATE OF COMPLIANCE ... ... (California Education Code 17620) Project'Naine:..Hideaway Date: April,20,.2012.. .. :..: Owner's Name::: ::John and Nancy Kavaiotidis:: Phone No. 760-880-1761 Project Address: 53-607 Via Palacio, LaQuinta; CA- 92253 " " Project Description:—: Single Family Dwelling" ...... ....... APN;: ..777-220-008 Tract #::: Lot #'s:.: . Type of Development:: .: Residential . : X^%X :Commercial .: Industrial: Total Square Feet of Building Area: . 5,349 Certification of-Applicaiit/Owners:..The:person signing certifies that the above information is correct and makes this statement under penalty of er ur and further represents that he/she: o sin n behalf the owner/develo er P Y ..: P J.. Y P.. ... P Dated: April 20, 2012....... ... Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ; ACCORDANCE WITH ONE.OF THE FOLLOWING: .(CIRCLE ONE)... ;Education Code.:: .:: Gov. Code ; Project:. Agreement Existing Not Subject to Fee . .. 17620 .65995 Approval Prior to 1/1/87 Requirement ...... ..... ... Note• . . Number of Sq.Ft..: . 5-;349 "' ' Pursuant to AB 181 any:r oom additions or enclosures of 500 ; :: , sq: ft. or less are exemptfrom developer fees. Any_mobile Amoitnt.per:Sq.Ft. $2.97. homes bei pg, within the same school district's:'.: Amount Collected.. _ $15886.53 jurisdiction are. exempt from developer fees.." Building Permit Application Completed'. Yes/No By: Elsa'E. Esqueda, Director: of Facilities and Maintenance Certificate issued by: Laurie Howard; Secretary .... Signature:. ....NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES�AND.STATEMENT OF. FEES ... Section 66020 of the:Goveenment Code asserted by Assembly Bill 3081, effective:January 1, 1997, requires that -this District provide,(1).a.written notice to. the project appellant, at the time:of payment of school fees, mitigation payment or other exactions ("Fees" ), of the 90 -day period to protest the imposition of these' Fees and (2) the amount of the fees." Therefore, in accordance with.sec6on 66020 of the Government code and other applicable law, this Notice shall:serve to advise you that the 90 -day protest period in regard to such:Fees.or. the validity thereof; commences with the payment.of-the fees or performance of any other requirements as described in section 66020'oft he Government code." Additionally, the amount of the. fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance: of a,Certifcate of Occupancy.. As.in the latter, the 90 days starts on the date hereof._ This Certificate of Compliance is valid for thirty, (30) days from the.date:of;i : uance. Extensiori will be: granted only for good cause, as determined by the 3ckool District, and up' ; . to three (3) such extensions may be granted." N4v:c/nlydocs/deifees/certificate of compliance form updated 3-2007 :. :' 11/2010 DOC 48 2003."1091-49 frMELITY NATIONA:LTITL , (-0MRkNY02/d.4/2063 08:00A fee:22.00 . SI)I31)1VI.SI(�N DEPARTMENT Page 1 of 8 Doe T Tax PaidRecorded in Official Records WHEN RECORDED MAIL TO' County. of Riverside John Kava iotidis, Trus.tee Gary t jerk yAssessor,. County Clerk 8 Recorder P.O. Bos 2.13 Pebble Beach, CA 93953 I II�III IIIIII IIII IIII �II�III'�III �I�IIII III,III�I�IIII'llll • MAIL TAX STATEMENT TO: M S U I PAr' 52° DA POO/A 'NOCOR I SMF "C. SAME AS ABOVE A R . l COPY LONG : ,.REFUND.;NCHG-1 / EXAM . DOCUMENT TRANSFER TAX XX Computed on the consideration or value of property conveyed- OR Computed on the consideration or value less liens or encumbrances remaining at the time of sale. I Signature of Declarant or Agent determining tax.—.Finn Narue � X12 5Le0'. GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is 'hereby •acknowledged; ND LA Q.UI.NTA PARTNERS, LLC, a.Delaware limited liability company ("Grantor") herebyGRANT(S)to JOHN KAVAYIOTIDIS AND NANCY KAVAYIOTIDIS, OR THEIR SUCCESSOR(s), AS TRUSTEES OF THE JOHN AND NANCY KAVMIOTID S 79 ER 14, .1999 .. ("Grantee"), the real property located in the City of La Quinta, County of Riverside, State of California, described as: See :Legal Description attached hereto and incorporated herein as Exhibit "A SUBJECT TO all matters of record including, without limitation, the covenants and agreements described in Eahib.it "A" attached hereto, Dated: January 20, 2003 ND LA QUINTAPARTNERS, LLC, a Delaware limited liability company By: Nationwide Realty Investors, Ltd., an Ohio limited liability ci mpa-y its'managing m ber, By: Josepl:L.Arenson Authorized Representative_ J. " I-LV627969.1. _ . i i l s EXHIBIT "A". Legal Description Parcel No. 1.: Lot 222 (the "Lot") of Amended Tract No. 29894-2 as shown on a Subdivision Map (the "Map") recorded on December 12, 2002; in Book 327, Pages 56 to 88', inclusive, ofMaps, in the Office of the Riverside County Recorder. EXCEPTING AND RESERVING THEREFROM TO GRANTOR; and its successors, assigns, invitees, licensees and. employees, together with the right to grant and, transfer all.:or a. portion of the same,. all easements and rights for access, in egress, encroachment, maintenance, drainage,- support, and for other purposes over. the Association.Nlairitenance Areas and: other portion of the Lot, reserved to Grantor in the following instruments: 1. The Amended: and Restated Declaration of Covenants; Conditions.and Restrictions and Reservation of Easements for The.Hi'deaway Owners Association (as amended' or supplemented; .the "Declaration"), recorded on December 13, 2002, as Instrument No. 20.02'- 745.930, 002=745935, of`Offi:cial Records of Riverside County, California (the "Official Records? ); FURTHER RESERVING THEREFROM,; the right to enter the Lot for a term of twelve (12) months following, the recordation of this Grant Deed, to complete:and repair any improvements or landscaping located thereon as determined necessary by Grantor; in Its: sole discretion, in order to comply with. requirements for the recordation. of the Final Tract Map, the grading of. said Tract and/or in compliance with the requirements of applicable governmental agencies. Such entry by Grantor shall be preceded by reasonable notice to Grantee before such entry. If this reservation of right of entry is not complied with by Grantee, Grantor may enforce this right of entry in a court of law. Grantee shall be responsible for all damages arising out of said breach including attorneys' fees and court costs. This reservation of right of entry shall automatically expire twelve (1.2) months from the recordation of this.Grant Deed. Parcel No. 2: Nonexclusive easements for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as described in the Declaration. SUBJECT TO: Nondelinquent general, special and supplemental real property taxes and assessments. 2. All other covenants, conditions, restrictions, reservations, easements, rights and . rights-of-way of record including, without Limitation, the Declaration and the Map for"Tract No. 29894-2. Ilflll`I�IIII III III �IIIIII IIII II'I�'I III ��I�I �I�) I��I '1,`41@ 3f c98:0 i'l I -L: V627969.1 t_ BUILDING ENERGY ANALYSIS REPORT PROJECT: Kavas Residence _ - - Lot 222 - Hideaway La Quinta, CA 92253 . Project Designer:. Helton -DeFord & Assoc. 1261 N. Big Springs St. Anaheim Hills, CA 92807 (909) 957-4550 _ Report Prepared by: Scott DeVoe BREEZE AIR CONDITIONING - 75-145 St. Charles Place Palm Desert, CA 92211 (760) 346-0855 a -o -W - CITY OF LA QUANTA BUILDING & SAFETY DEPT. APPROVED JUN 0 12012 FOR CONSTRUCTION BY. DATE Y-_ JobWu—mWe-r- . Date: 5/9/2012 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. ` This program developed by EnergySoft, LLC - www.energysoft.com. 1. EnergyPro 5.1 by EnergySoff User Number. 3665 .. RunCode: 2012-05-09T09:42:47 ..--1D:.. .. -_. • . . - : ,- C • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Kavas Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/9/2012 Project Address Lot'222 - Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,349 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features (see Part 2 of 5) Status Roof Wood Framed Attic R-38 5,523 New Wall Wood Framed R-21 - 4,268 - New Slab Unheated Slab -on -Grade None 5,349 Perim = 450' New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefirts Shades Status Left (N) 11.3 0.370 0.32 none none Bug Screen New Left (N) 22.5 0.370 0.32 none none Bug Screen New Rear (E) 40.0 0.340 0.36 none none Bug Screen New Rear (E) 40.0 0.340 0.36 none none Bug Screen New Rear (E) 40.0 0.340 0.36 none none Bug Screen New Right (S) 40.0 0.290 0.28 20.0 none Bug Screen New Right (S) 32.0 0.340 0.36 20.0 none Bug Screen New Right (S) 18.0 0.340 0.36 20.0 none Bug Screen New Right (S) 27.5 0.340 0.36 none none Bug Screen New Front (M 27.5 0.340 0.36 none none Bug Screen New Left (N) 12.5 0.340 0.36 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 8.50 HSPF Split Heat Pump 16.2 SEER Setback New 1 Split Heat Pump 8.50 HSPF Split Heat Pump 15.5 SEER Setback New 1 Split Heat Pump 8.50 HSPF Split Heat Pump 16.2 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Zone #1 Ducted Ducted Conditioned 6.0 New Zone #2 Ducted Ducted Conditioned 6.0 New Zone #3 Ducted Ducted Conditioned 6.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 2 Large Gas 75 0.80 Kitchen Pipe Ins New Ener Pro 5.1 by EnergySoft User Number: 3665 RunCode: 2012-05-09709:42:47 ID: Page 3 of 33 • 0 0 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Kavas Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/9/2012 Project Address -- . • • -• - : Lot 222 - Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,349 Addition # of Stories FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Left (N) 27.5 0.340 0.36 none none Bug Screen New Left (N) 27.5 0.340 0.36 none none Bug Screen New Rear (E) 220.0 0.480 0.28 16.0 none Bug Screen New Front (W) 36.0 0.290 0.28 3.0 none Bug Screen New Front (W) 48.0 0.340 0.36 3.0 none Bug Screen New Front (IM 27.5 0.340 0.36 none none Bug Screen New Rear (E) 56.0 0.290 0.28 none none Bug Screen New Rear (E) 56.0 0.290 0.28 4.0 none Bug Screen New Right (S) 13.8 0.370 0.32 none none Bug Screen New Right (S) 13.8 0.370 0.32 none none Bug Screen New Right (S) 8.0 0.370 0.32 none none Bug Screen New HVAC SYSTEMS - ' .`. . . Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 • • Split Heat Pump 8.50 HSPF Split Heat Pump 16.2 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Zone #4 Ducted Ducted Conditioned 6.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by Ener Soft User Number: 3665 RunCode: 2012-05-09709:42:47 ID: Page 4 of 33 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Kavas Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/9/2012 Project Address Lot 222 - Hideaway - La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area - 5,3,e Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST a Yes ❑ No HERS Measures --,If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Orientation Area(ft) Factor Exterior -SHGC OVerhang Sidefins Shades = ' = Status Right (S) 45:0 0.370 0.32 none none Bug Screen New Left (N) 13.8 0.370 0.32 none none Bug Screen New" Rear (E) 56.0 0.290. 0.28 none none Bug Screen New Right (S) 13.8 0.370 0.32 none.. none Bug Screen New Right (S) 13.8 0.370 0.32 none none Bug Screen New Right (S) 4.5 0.340 0.36 none none Bug Screen New Right (S) 4.5 0.340 0.36 none none Bug Screen New Right (S) 13.8 0.370 0.32 none none Bug Screen New. Right (S) 13.8 0.370 0.32 none none Bug Screen New Right (S) 41.3 0.370 0.32 none none Bug Screen New Right (S) 13.8 0.370 0.32 none none Bug Screen New HVAC SYSTEMS : • - Qt . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location 'Heating. Duct Cooling Duct Location - •R -Value .Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number. 3665 RunCdde: 2012=05=09T09:42:47 /D: Page 5 of 33 C PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Kavas Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/9/2012 Project Address Lot 222 - Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,349 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes. ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION . Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC "Overhang Sidefins Shades Status Right (S) 13.8 0.370 0.32 none none Bug Screen New Right (S) - 13.8 0.370 -0.32 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff- Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING . Ot . Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2012-05-09709:42:47 ID: Page 6 of 33 17-4 0 "PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Kavas Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/9/2012= .SPECIAL FEATURES INSPECTION .C.HECKLIST The enforcement agency should pay special attentibn'to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building'or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford White 75 Gal is a non-NAECA large storage gas water heater. Verify DHW details. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. -The Cooling System Lennox XP16/CBX32MV (4 Ton) includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. t The HVAC System Zone #1 has Ducts, Plenums and the HVAC unit located totally within. Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. .: ,f The HVAC System Zone #1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Lennox XP16/CBX32MV (5 Ton) includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the , installation of the correct Condenser. The HVAC System Zone #2 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verity that duct leakage meets the specified criteria. The Cooling System Lennox XP161CBX32MV'(4 Ton) includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System Zone #3 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the. specified criteria. The Cooling System Lennox XP16/CBX32MV (4 Ton) includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System Zone #4 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ehei Pro 5.1 by Ener" y Soft User Number: 3665 RunCode: 2012-05-09709:42:47 ID: - 'Paq& 7 of 33 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Kavas Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 5/9/2012 ANNUAL ENERGY USE SUMMARY Standard. Proposed . Margin . TDV kBtu/ft_yr) Space Heating 4.28 2.58 1.70 Space Cooling 52.14 48.72 3.43 Fans 10.27 14.24 -3:97 Domestic Hot Water 6.82 4.69 2.13 Pumps 0.00 0.00 .0.00 Totals 73.52 70.23 3.28 Percent Better Than Standard: 4.5% - BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (M 270 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (14 1,086 139 Fuel Available at Site: Natural Gas(N) 1,441 415 - Raised Floor Area: 0 (E) 1,421. 508 Slab on Grade Area: 5,349 (S) 1;427 345 Average Ceiling Height: 11.1 Roof 5,523 0 Fenestration Average U -Factor: 0.36- TOTAL: 1,107 Average SHGC: 0.32' Fenestration/CFA Ratio: ' 20.7 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company ` BREEZE AIR CONDITIONING 5/9/2012 Address 75-145 St. Charles Place Name Scott Devoe City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone (760) 346-0855 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) . Company Helton DeFord & Assoc. Address .1261 N. Big Springs St. Name City/State/Zip Anaheim Hills, CA 92807 Phone (909) 957-4550 Signed License # Date EnenqWro 61 b ' Ene-gy8oft User Number. 3665 RunCode: 2012-05-09709:42:47 ID:'-- Page 8 -of 33 CERTIFICATE OF COMPLIANCE:. Residential (Part 4 of 5) CF -1 R Project Name Kavas Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 151912012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Roof 1,267 0.025 R-38 270 0 New 4.2.1-A21 Zone #1 Wall 587 0.069 R-21 0 90 New 4.3.1-A6 Zone #1 Wall 220 0.069 R-21 90 90 New 4.3.1-A6 Zone #1 Wall 163 0.069 R-21 1801 90 New 4.3.1-A6 Zone #1 Wall 91 0.069 R-21 270 90 New 4.3.1-A6 Zone #1 Slab 1,267 0.730 None 0 180 New 4.4.7-A1 Zone #1 Roof 1,594 0.025 R-38 270 0 New 4.2.1-A21 Zone #2 Wall 368 0.069 R-21 0 90 New 4.3.1-A6 Zone #2 Wall 200 0.069 R-21 90 90 New 4.3.1-A6 Zone #2 Wall 75 0.069 R-21 180 90 New 4.3.1-A6 Zone #2 Wall 377 0.069 R-21 270 90 New 4.3.1-A6 Zone #2 Slab 1,594 0.730 None 0 180 New 4.4.7-A1 Zone #2 Roof 1,204 0.025 R-38 270 0 New 4.2.1-A21 one #3 Wall 60 0.069 R-21 0 90 New 4.3.1-A6 Zone #3 Wall 349 0.069 R-21 90 90 New 4.3.1-A6 Zone #3 Wall 439 0.069 R-21 180 90 New 14.3.1-A6 Zone #3 FENESTRATION SURFACE DETAILS ID - Type Area U -Factor SHGC2 Azm Status: Glazing Type Location/Comments 1 Window 11.3 0.370 NFRC 0.32 NFRC 0 New Wd Clad Lo/E (Csmt) (105) Zone #1 2 Window 22.5 0.370 NFRC 0.32 NFRC 0 New Wd Clad Lo/E (Csmt) (106) Zone #1 3 Window 40.0 0.340 NFRC 0.36 NFRC 90 New Wd Clad Lo/E (Fxd) (107) Zone #1 4 Window 40.0 0.340 NFRC 0.36 NFRC 90 New Wd Clad Lo/E (Fxd) (108) Zone #1 5 Window 40.0 0.340 NFRC 0.36 NFRC 90 New Wd Clad Lo/E (Fxd) (109) Zone #1 6 Window 40.0 0.290 NFRC 0.28 NFRC 180 New Wd Clad Lo/E (Swng Dr) (1F) Zone #1 7 Window 32.0 0.340 NFRC 0.36 NFRC 180 New Wd Clad Lo/E (Fxd) (1F) Zone #1 8 Window 18.0 0.340 NFRC 0.36 NFRC 180 New Wd Clad Lo/E (Fxd) (1F) Zone #1 .9- Window 27.5 0.340 NFRC 0.36 NFRC': _.180 New Wd Clad Lo/E (Fxd) (100) Zone #1 -.10 Window 27.5 0.340 NFRC -0.36 NFRC '270 New ` Wd Clad L&E (Fxd) (100) Zone #1 11 Window 12.5 0.340 NFRC 0.36 NFRC 0 New Wd Clad Lo/E (Fxd) (125) Zone #2 12 Window 27.5 0.340 NFRC 0.36 NFRC 0 New Wd Clad Lo/E (Fxd) (126) Zone #2 13 Window 27.5 0.340 NFRC 0.36 NFRC 0 New Wd Clad Lo/E (Fxd) (127) Zone #2 14 Window 220.0 0.480 NFRC 0.28 NFRC 90 New Wd Clad Lo/E (SGD) (1 G) Zone #2 15 Window 36.01 0.290 NFRC 0.28 NFRC 270 New Wd Clad Lo/E (Swng Dr) (1A) Zone #2 16 Window 48.01 0.340 NFRC 0.36 1 NFRC 270 New Wd Clad Lo/E (Fxd) (1A) Zone #2 (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Overhang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 '5 Bug Screen 0.76 6 Bug Screen 0.761 8.0 5.0 20.0 2.0 20.0 20.0 7 Bug Screen 0.76 8.0 4.0 20.0 2.0 20.0 20.0 8 Bug Screen 0.76 2.0 9.0 20.0 0.1 20.0 20.0 9 Bug Screen 0.76 .10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 10.0 22.0 16.0 2.0 16.0 16.0 15 Bug Screen 0.76 9.0 4.0 3.0 2.0 3.0 3.0 16 Bug Screen 0.76 24.0 2.0 3.0 0.1 3.0 3.0 Ener Pro 5.1 by EnergySoft User Number: 3665 RunCode: 2012-05-09709:42:47 ID: Page 9 of 33 0 F" I`_ J CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Kavas Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/9/2012 OPAQUE SURFACE DETAILS Surface Type Area U Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 30 0.069 R-21 270 90 New, 4.3.1-A6 Zone #3 Slab 1,204 0.730 None 0 180 New 4.4.7-A1 Zone #3 Roof .1,458 0.025 R-38 270 0 New 4.2.1-A21 Zone #4 Wall 3111 0.069 R-21 oil 90 New 4.3.1-A6 Zone #4 Wall 144 0.069 R-21 90 90 New 4.3.1-A6 Zone #4 Wall 405 0.069 R-21 180 90 New 4.3.1-A6 Zone #4 Wall 450 0.069 R-21 270 _ 90 New 4.3.1-A6 Zone #4 Slab 1,284 0.730 None 0 180 New 4.4.7-A1 Zone #4 FENESTRATION SURFACE DETAILS ID I Type Area U -Factor_ aHGC: Azm Status Glazing Type Location/Comments 17 Window 27.5 0.340 NFRC 0.36 NFRC 276 New Wd Clad Lo/E (Fxd) (128) Zone #2 18 Window 56.0 0.290 NFRC 0'.28 NFRC 90 New Wd Clad Lo/E (Swng Dr) (1H) Zone #3 19 Window 56.0 0.290 NFRC 0.28 NFRC 90 New Wd Clad Lo/E Swng Dr) (1J) Zone #3 20 Window 13.8 0.370 NFRC 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) (110) Zone_#3 21 Window 13.81 0.370 NFRC 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) (111) Zone #3 22 Window 8.0 0.370 NFRC 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) (112) Zone #3 23 Window 45.0 0.370 NFRC 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) (113) Zone #3 24 Window 13.8 0.370 NFRC 0.32 NFRC 0 New Wd Clad Lo/E (Csmt) (124) Zone #4 25 Window 56.0 0.290 NFRC 0.28 NFRC 90 New .. Wd Clad Lo/E (Swng. Dr) (1K) Zone. #4 26 Window 13.8 0.370 NFRC; "''1 �O.32 NFRC 180New Wd Clad Lo/E (Csmt) (114) Zone #4 27 Window 13.8 0.370 NFRC 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) (115) Zone #4 28 Window 4.5 0.340 NFRC 0.36 NFRC 180 New Wd Clad Lo/E (Fxd) (116) Zone #4 29 Window 4.5 0.340 NFRC 0.36 NFRC 180 New Wd Clad Lo/E (Fxd) (117) Zone #4 30 Window 13.8 0.370 NFRC 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) (I 18) Zone #4 31 Window 13.8 0.370 NFRC 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) (119) Zone #4 32 Window 41.3 0.370 NFRC 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) (120) Zone #4 (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt REA Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 8.0 7.0 4.0 0.1 4.0 4.0 20 Bug Screen 0.76 •21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 JBug Screen 0.76 32 JBug Screen 0.76 Ener Pro 5.1 by Ener Soft llserNumber.._3665 RunCode: 2012-05-09709:42:47 ID: Pae 10 of 33 r CERTIFICATE OF COMPLIANCE: Residential . (Part 4 of 5) CF -1 R Project Name Kavas Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/9/2012 OPAQUE SURFACE DETAILS Surface Ll- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC2 Azm Status Glazing Type Location/Comments 33 Window 13.8 0.370 NFRC 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) (121) Zone #4 34 Window 13.8 0.370 NFRC 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) (122) Zone #4 35 Window 13.8 0.370 NFRC 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) (123) Zone #4 (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC T e: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Overhang Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len H t Dist Len H qA 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 Ener Pro 5.1 by, Energysoft User Number: 3665 RunCode: 2012-05-09709:42:47 ID: . Pa e..11 of 33 • • n CERTIFICATE OF COMPLIANCE: Residential. (Part 5 of 5) CF -1 R Project Name Kavas Residence Building Type ❑ Single Family ❑ Addition Alone '.I ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/9/2012 BUILDING ZONE INFORMATION a System Name = Zone Name Floor Area New Existinq Altered Removed Volume Year Built Zone #1 Kitchen / Family 1,267 13,937 Zone #2 Entry/ Great Rm /Hall 1,594 19,128 Zone #3 Mst. Suite/ Office 1,204 - 13,244 Zone #4 Bed #2 & 3/Guest Suite "1,284 • 12,840 Totals 5,3491 0 0 0 HVAC SYSTEMS System Name Ot . Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Zone #1 1 Split Heat Pump 8.50 HSPF Split Heat Pump 16.2 SEER Setback New Zone #2 1 Split Heat Pump 8.50 HSPF Split Heat Pump 15.5 SEER Setback New Zone #3 1 Split Heat Pump 8.50 HSPF Split Heat Pump 16.2 SEER Setback New Zone #4 1 Split Heat Pump 8.50 HSPF Split Heat Pump 16.2 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Zone #1 Ducted Ducted Conditioned 6.0 m New Zone #2 Ducted Ducted Conditioned 6.0 m New Zone #3 Ducted Ducted Conditioned 6.0 El New Zone #4 Ducted Ducted Conditioned 6.0 m New WATER HEATING SYSTEMS S "stem Name Ot . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford White 75 Gal 2 Large Gas Kitchen Pipe Ins 76,000 75 0.80 0.00% n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft � 2 6 a — System Name Pipe Length Pipe Diameter Insul. Thick. Ot . HP Plenum Outside Buried 01 a 0- EnergyPro 5.1 by Ener Soft User Number. 3665 RunCode: 2012-05-09709:42:47 ID: Pae 12 of 33 4 4 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Y Kavas Residence Date ' 5/9/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R - ALT Form) shall supersede the items marked with an asterisk (').below. This Mandatory Measures Summary.shall be incorporated into the permit-documents,'and the applicable features shall be considered by all parties -as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. 0 -' Building Envelope Measures: - 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). • 117: Exterior doors and windows are weather-stripped; all joints andpenetration's are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. 150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. , *§l 50 c : Minimum R-13 insulation in wood-framemall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed •according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 perm/inch and shall be , protected from physical damage and UV light deterioration. fireplaces, Decorative Gas Appliances and Gas Log Measures: . • 150 e 1 A: Mason or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is lequipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when -that indoor air is vented to the outside of the building, are prohibited. - Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy • Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling.units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical' supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance -with ASHRAE, SMACNA or ACCA. ` 150(i): Heating systems are equipped with thermostats that meet the setback re uirements•of Section 112 c §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. ;. • §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal. insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. •§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table•l50-B and E uation"150-A. 1 3 • §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. ' §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(i)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro:5.1 by EnergySok ' . _User Number• 3665 -... _ . RunCode:,2012-05-09709:42:47 ID: -Page 13 of 33;. 4 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Kavas Residence 5/9/2012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections. 601, 602, 603, 604, 605 and Standard 6-5; supply -air and_ return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 1 50 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand loeriods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Wafts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. e EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2012-05-09709:42:47 ID: Page 14 of 33 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R .Project Name Date Kavas Residence 5/9/2012 §150(k)l0:Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. E=XCEPTION 1': Permanently installed low eff'ica'cy luminaires shall be allowed provided that they are controlled by a manual -ori occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square.feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be .allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual-, `on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between . the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that 'they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management .control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not -be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable ;requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. t EnergyPro 5.1 by Energyso(t User Number. 3665 +WunCode- 201.2-05=09709:42:47 C :ID: Page' 18 of33 4 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Kavas Residence Date 5/9/2012 System Name •one.#1. Floor Area 1,267 ENGINEERING CHECKS SYSTEM LOAD Number of S stems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 971 17,412 Return Vented Lighting 0 Return Air Ducts 270 Return Fan 0 Ventilation 91 3,762 Supply Fan 0 Supply Air Ducts 270 TOTAL SYSTEM LOAD 21,712 COIL HTG. Latent CFM 1,875 734 1,850 . 91 3,726 PEAK Heating System Sensible Output per System 44,000 19,417 Total Output Btuh 44,000 Output Btuh/s ft 34.7 226 Cooling System 0 Output per System 47,500 5,217 Total Output (Btuh) 47,500 0 Total Output (Tons) 4.0 226 Total Output Btuh/s ft) 37.5 Total Output s ftfTon 320.1 25,086 Air System CFM per System 1,6001 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Lennox XP16/CBX32MV (4 Ton) 36,705 3,781 27,481 Airflow (cfm/s ft) 1.26 Airflow cfm/Ton) 404.2 Outside Air % 5.7% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 36,705 3,781 27,481 Jan 1 AM Outside Air (cfm/s ft) 0.07 ote: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Tem eratures at Time of Heating Peak) 26 OF 77 OF yy Outside Air 91 cfm Supply Fan 1,600 cfm 80 OF 77 OF 105 OF Heating Coil I 105 OF ROOM 80 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 111 / 78 OF 74 / 62 OF 74 / 62 OF 55 / 54 OF Outside Air 91 cfm Supply Fan Cooling Coil 1,600 cfm 53.0% 72/61 OF 55 / 54 OF ROOMas' 72/61 OF �EnergyPro 5.1 by EnergySoR User Number. 3665. RuilCode: 2013=05=0,049:43:47 /D: `Page'16 of 33 4 4 4 HVAC SYSTEM. HEATING_ AND COOLING LOADS SUMMARY Project Name Kavas Residence Date 5/9/2012 System Name one #2 - _. _ _ _ -. - Floor Area 1,594 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM -Total Room Loads 971 Return Vented Lighting Return Air Ducts Return Fan Ventilation 273 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 55,500 17,509 1,856 920. 24,420 Total Output Btuh 55,500 0 Output Btuh/s ft 34.8 271 285 Cooling System 0 0 Output per System 57,000 11,313 5,779 273 15;670 Total:Out ut (Btuh) 57,000 0 271 1 29,365 7,635 0 Total Output Tons 4.8 285 Total Output (Btuh/s ft) 35.8 Total Output s ft/Ton 335.6 40,660 Air System CFM per System 4,250 HVAC EQUIPMENT SELECTION Airflow cfm 4,250 Lennox XP16/CBX32MV (5 Ton) 35,130 13,348 34,664 Airflow cfm/s ft 2.67 Airflow cfm/Ton) 894.7 34,664 Jan 1 AM Outside Air (%) 6.4% Total Adjusted System Output 35,130 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 13,348 Aug 3 PM Outside Air (cfm/s ft) 0.17 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 76 OF Outside Air 273 cfm Supply Fan 4,250 cfm 80 OF 76 OF 105 OF Heating Coil 105 OF ROOM 80 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 111 / 78 OF 75 / 62 OF 75'/ 62 OF 55 / 54 OF Q .Outside Aires ` 273 cfm Supply Fan Cooling Coil 55 / 54 OF 4,250 cfm 52.0% ROOM 72 / 61 OF 72 / 61 OF EnergyPro 5.1 by EnergySoft U7 ii Nbrn&&•:3666. -- 'RunCode: 2012-05-09709:42:47 ID: Pa'6 17'6f 33 4 i HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Kavas Residence 5/9/2012 System Name Floor Area one #3 1,204 . ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL ' CFM Total Room Loads 614 Return Vented Lighting Return Air Ducts Return Fan Ventilation 182 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating -System Sensible Latent CFM Sensible output per System 44,000 11,039 - 1,602 601 15,909 Total Output (Btuh) 44,000 0 - Output (Btuh/sqft 36.5 171 186 Cooling System 0 0 Output per System 47,500 7,534 3,778 182 10,438 Total Output (Btuh) 47,500 0 5,3801 0 Total Output (Tons) 4.0 171 186 Total Output (Btuh/s ft) 39.5 Total Output s ft/Ton 304.2 1 18,916 26,718 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Lennox XP16/CBX32MV (4 Ton) 38,311 2,804 27,481 Airflow cfm/s ft 1.33 27,481 Jan 1 AM Airflow cfm/Ton 404.2 Outside Air (%) 11.4% Total Adjusted System Output 38,311 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 2,804 Aug 3 PM Outside Air (cfm/s ft) 0,15 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 74 OF 74 OF 105 OF Outside Air 182 cfm Supply Fan Heating Coil 105 OF 1,600 cfm ROOM 80 OF 80 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 111!78°F 77/63°F 77/63°F 55/54°F Outside Air 182 cfm Supply Fan Cooling Coil 55 / 54 OF 1,600 cfm 52.5 % ROOM 72 / 61 OF 72 ! 61 °F E6et406 5.1 by FnergySoft Wer -Number: 3665 RunCode: 2012-05-09T09:42:47 ID: - Page 18'of'33 4 4 4 HVAC- SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Kavas Residence 5/9/20.12 System Name-. - Floor Area one #4; .... _ c 1,284 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 732 Return Vented Lighting Return Air Ducts Return Fan Ventilation 364 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 1 COOLING PEAK COIL HTG. PEAK Heating System Sensible 'Latent CFM Sensible Output per System 44,000 13,158 2,295 773 20,445 Total Output (Btuh) 44,000 0 Output Btuh/s ft 34.3 204 238 Cooling System 0 0 Output per System 47,500 15,061 7,555 364 20,864 Total Output Btuh) 47,500 0 204 28,627 9,850 0 Total Output (Tons) 4.0 238 Total Output (Btuh/s ft) 37.0 Total Output s ft/Ton 324.4 41,786 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Lennox XP16/CBX32MV (4 Ton) 41,342 1,228 27,481 Airflow cfm/s ft 1.25 Airflow (cfm/Ton) 404.2 Outside Air (% 22.8% Total Adjusted System Output 41,342 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1,228 Aug 3 PM 27,481 Jan 1 AM Outside Air cfm/S ft 0.28 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 68 OF 68 OF 105 OF a. Outside Air 364 cfm Supply Fan Heating Coil 105 OF 1,600 cfm i l ROOM 80 OF 80 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak) 111 / 78 OF 81 / 65 OF 81 / 65 OF 55 / 54 OF ,1 ,---` Outside Air 364 cfm Supply FanAL Cooling Coil 55 / 54 OF - 1,600 cfm - - --- - - 52.5 % ROOM 72/61 OF i 72 / 61 OF 'EnergyAi&5:1 by EnergySoft' User Number: 3665' RunCode:'20 =0549T09:42:47 -ID:: - Pa ge19 of 33 Total includes ventilation load for zonal systems. PAGE TOTAL TOTAL* 971 17,412 1,875 734 19,417 9711 ROOM LOAD SUMMARY 1,8751 7341 19, 417 Project Name Kavas Residence Date - 51912012 System -Name Zone, #1 Floor Area 1, 267 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone #1 Kitchen /Family 1 971 17,412 , 1,875 971 17,412 :. 1,875 734 19,417 Total includes ventilation load for zonal systems. PAGE TOTAL TOTAL* 971 17,412 1,875 734 19,417 9711 17,4121 1,8751 7341 19, 417 i ROOM LOAD SUMMARY Project Name Date Kavas Residence 5/9/2012 System Name Floor Area Zone #2-"' 1,594 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name + Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone #2._ . _..: Entry / Great Rm / Hall 1 971 17,509 1,856 971 17,509 1,856 920 24,420 PAGE TOTAL TOTAL. Total includes ventilation. load.for.zonal systems _ Ener Pr6-SA b Ene •Soft= . Wer`N6iTiH r 3665 RunCode`'2012-05=09T09:42:47 971 17,509 1,856 920 24,420 971 17,509 1,856 920 24,420 ID: ,_Page 21 `of3: ROOM -LOAD SUMMARY' - Project Name Date - Kavas Residence 5/9/2012 System' Name Floor Area Zone #3 ` 1,204 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult." "CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone #3 : , _ , Mst. Suite/ Office 1 614 11,039 1,602 614 11,039. , 1;602 601 -•15,909 PAGE TOTAL 614 • 11,0391 1,6021 601. 15,909 TOTAL 614 11,039 1,602 601 15,909, ' Totalincludes ventilation load for zonal systems.. Ener' "Pro 5:.1 b" `- Ener Soft. User Numb&. 3665 ' Runcode: 2012-05-09709:42:47 ID: -.: Pa a 22' of 33 • ROOM LOAD SUMMARY Project Name Date Kavas Residence 5/9/2012 System Name - — Floor Area Zone #4 _ 1,284 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone #4 Bed #2 & 3 / Guest Suite 1 732 13,158 2,295 732 13,158 Z 295 773 20,445 '.Total includes ventilation load for zonal systems. Eh6rbvPro' 5:1 by EneravSoft User Number 3665 RnnC PAGE TOTAL TOTAL' 732 13,158 2,295 773 20,445 732 13,158 2,295 773 20,445 >012-05-09T09}42:47 " ID: Paae 23 C E u r� ROOM HEATING PEAK LOADS Project Name Kavas Residence Date 5/9/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen / Family Floor Area 1,267.0 ft' Indoor Dry Bulb Temperature 80 OF Time of Peak" Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value ' 1,267.0 . X 0.0250 1,060.2 X 0.0690 11.3 X : 0.3700 22.5 X 0.3700 40.0 X 0.3400 40:0 X 0.3400 40.0 X 0.3400 40.0 X 0.2900 50.0 X 0.3400 55.0 X 0.3400 perim = 107.0 X 0.7300 X X X X X X X X X X" X X X X X X X X X X through an interior surface to another room X 1,267 X 11.00 X 0.308 Area Ceiling Height ACH X X X X .X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F - 54 = 54 = Btu/hr R-38 Roof 010 R-21 Wall 3,950 Wd Clad Lo/E (Csmt) (105) 54 = = 226 Wd Clad Lo/E (Csmt) (106) 54 450 Wd Clad Lo/E (Fxd) (107) 54 = = = 734 Wd Clad Lo/E (Fxd) (108) 54 734 Wd Clad Lo/E (Fxd) (109) 54 734 Wd Clad Lo/E (Swng Dr) (IF) 54 = = 626 Wd Clad Lo/E (Fxd) (1F) 54 918 Wd Clad Lo/E (Fxd) (100) 54 = 1,010 Slab -On -Grade 54 = = = = 4,218 = = = = = = = = = = = = = = Page Total /60] X 54 AT i.. _ Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064. Schedule Air Sensible Fraction 15,311 = 4,106 TOTAL HOURLY HEAT LOSS FOR ROOM 19,417 EnergyPro 5.1 by EnergySoft Wer!Number.: 3665,: , _ RdnCode:'2012-05'-09709:42:47' ID: Page 24 of 33 IM -ROOM HEATING PEAK LOADS. Project Name- Kavas Residence Date 5/9/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Entry / Great Rm / Hall Floor Area 1,594.0 ft2 Indoor Dry Bulb Temperature 80 OF Time of Peak " Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF Btu/hr = 2,152 '= 3,797 _ 230 = 505 _ 505 = 5,702 = 564 = 881 = 505 '`_ 4,415 = = = _ = _ _ _ = _ = = = = = = = = = = 19,255 54 = 5,165 R-38 Roof 1,594.0 X X 0.0250 54 R-21 Wall 1,019.0 0.0690 54 Wd Clad Lo/E (Fxd) (125) 12.5 X X X 0.3400 54 Wd Clad Lo/E (Fxd) (126) 27.5 0.3400 54 Wd Clad Lo/E (Fxd) (12 7) 27.5 0.3400 54 Wd Clad Lo/E (SGD) (1 G) 220.0 X 0.4800 54 Wd Clad Lo/E (Swng Dr) (1A) 36.0 X 0.2900 54 Wd Clad Lo/E (Fxd) (1A) 48.0 X X 0.3400 54 Wd Clad Lo/E (Fxd) (128) 27.5 0.3400 54 Slab -On -Grade perim = 112.0 X X X 0.7300 54 — _X X X x X X X X X X X X X X X X X X X Items shown "with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface to X 1,594 X Area Ceiling another room 12.00 X 0.282 Height ACH Page Total /60] X AT :TOTAL HOURLY HEAT LOSS FOR ROOM 24,420 1. EnergyPro ZdyyEnergySoft User.Number. 3665 , RunCode: 2012-05-09709:42:47: ID: Page>25 of -33.- 1 1' 0 ROOM HEATING PEAK LOADS Project Name Kavas Residence Date 5/9/20.1.2 ROOM 'INFORMATION DESIGN CONDITIONS Room Name Mst. Suite / Office Floor Area 1,204.0 ftZ Indoor Dry Bulb Temperature 80 °F Time of Peak � Outdoor Dry Bulb Temperature Jan 1 AM 26 OF Conduction Area R-38Roof 1,204.0 R-21 Wall 878.4 Wd Clad Lo/E (Swng Dr) (1H) 56.0 Wd Clad Lo/E (Swng Dr) (1J) 56.0 Wd Clad Lo/E (Csmt) (110) 13.8 Wd Clad Lo/E (Csmt) (111) 13.8 Wd Clad Lo/E (Csmt) (112) 8.0 Wd Clad Lo/E (Csmt) (113) 45.0 Slab -On -Grade perim = 95.0 - ^ Items shown with an asterisk (') denote conduction through an interior surface Infiltrationi 1.00 X 1.064 X 1,204 X Schedule Air Sensible Area Fraction U -Value AT °F ` X 0.0250 X . 54 = X 0.0690 X 54 = X 0.2900 X 54 = X 0.2900 X 54 = X 0.3700 X 54 _ X 0.3700 X 54 = X 0.3700 X 54 = X 0.3700 X 54 = X 0.7300 X 54 = X X = X X = X X = X X = X X - X X = X X = X X = X X = X X _ X X = X X = X X _ X X _ X X = X X _ X X - X X = X X X X _ X X = X X _ to another room Page Total 11.00 X 0.308 /60] X 54 Ceiling Height ACH AT Btu/hr- tu/hrR-38 1,625 3,273• 877 877 276 276 160. 899 3,745 1,2,008 = 3,901 TOTAL HOURLY HEAT LOSS FOR ROOM 15,909 EnergyPro 5.1 by EnergySoft User Number:. 3665 RunCode: 2012:05=09709:42:47' ID: Page 26 of 33 is ROOM HEATING PEAK LOADS Project Name Kavas Residence Date 5/9/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Bed #2 & 3 / Guest Suite Floor Area 1,284.0 ft2 Indoor Dry Bulb Temperature 80 OF Time of Peak Outdoor.Dry Bulb Temperature Jan 1 AM 26 OF Conduction Area U -Value R-38 Roof 1,458.0 X 0.0250 R-21 Wall 1,310.3 X 0.0690 Wd Clad Lo/E (Csmt) (124) 13.8 X 0.3700 Wd Clad Lo/E (Swng Dr) (1K) 56.0 X 0.2900 Wd Clad Lo/E (Csmt) (114) 13.8 X 0.3700 Wd Clad Lo/E (Csmt) (115) 13.8 X 0.3700 Wd Clad Lo/E (Fxd) (116) 4.5 X 0.3400 Wd Clad Lo/E (Fxd) (117) 4.5 X 0.3400 Wd Clad Lo/E (Csmt) (118) 13.8 X 0.3700 Wd Clad Lo/E (Csmt) (119) 13.8 X 0.3700 Wd Clad Lo/E (Csmt) (120) 41.3 X 0.3700 Wd Clad Lo/E (Csmt) (121) 13.8 X 0.3700 Wd Clad Lo/E (Csmt) (122) 13.8 X 0.3700 Wd Clad Lo/E (Csmt) (123) 13.8 X 0.3700 Slab -On -Grade perim = 136.0 X 0.7300 X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to another room Infiltration:[ 1.00 X 1.064 X 1,284 X 10.00 X 0.338 Schedule Air Sensible Area Ceiling Height ACH Fraction AT *F X 54 X 54 = Btu/hr 1,968 = = 4,882 X X 54 276 54 = 877 X 54 = = = 276 X X X X 54 276 54 83 54 = = 83 54 276 X 54 = = = = = 276 X X X X 54 825 54 276 54 276 54 276 X X X 54 = = = = 5,361 X X = = = X X X X X X = = = = = X X = = = = = X X X X Page Total /60] X AT 16,285 54 = 4,161 TOTAL HOURLY HEAT LOSS FOR ROOM 20,445 EnergyPro 5.1 by EnergySoft User Number. 3665 RunCode: 2012-05-09709:42:47 ID: Page 27 of 33 r 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Kavas Residence 5/9/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen / Family Outdoor Dry Bulb Temperature 111 OF Floor Area 1,267.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF Outdoor Dailv Ranae: 34 OF Oaaaue Surfaces R-38 Roof R-21 Wall R-21 Wall R-21 Wall R-21 Wall Orientation (N) (E) (S) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = 1,267.0 0.0250 56.0 587.2 0.0690 23.0 220.0 0.0690 33.0 162.5 0.0690 26.0 90.5 0.0690 33.0 27.5 20.4 Infiltration: 1.064 X 0.91 X 69.33 X 39 = 2,618 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Fenestration CsmtWdw (105) CsmtWdw (106) FxdWdw (107) FxdWdw (108). FxdWdw (109) SwngGlsDr (IF) FxdWdw (1F) FxdWdw (1 F) FxdWdw (101) Orientation (N) (N) (E) (E) (E) (S) (S) (S) (S) Area X X X X X 0.0 0.0 0.0 0.0 0.0 40.0 X X 32.0 18.0 X X 0.0 Unshaded Btu/hr 1,774 932 501 292 206 1 3,7041 + + + + + + + + + Area X X X X X X X X X GLF Occupants - 11.3 19.3 22.5 19.3 40.0 41.7 40.0 41.7 40.0 41.7 0.0 16.3 0.0 20.4 0.0 20.4 27.5 20.4 Page Total Btu/hr 219 435 1,667 1,667 1,667 651 650 366 561 7,8831 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = 460 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.91 X 69.33 X 39 = 2,618 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,412 Latent Gain Btu/hr Occupants 2•o Occupants X 200 Btuh/occ. _ 400 Infiltration: 4,771 X 0.91 X 69.33 X 0.00490 = 1,475 i Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1.875 0 C RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Kavas Residence 5/9/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen / Family Outdoor Dry Bulb Temperature 111 OF Floor Area 1,267.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X - X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr FxdWdw (100) (W) 0.0 X 20.3 + 27.5 X 41.7 c 1,146 X + X - X + X - X + X - X + X - X + X - X + X - X + X X + X = Page Total 1 1,146 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = 460 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.91 X 69.33 X 39 c 2,618 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,412 Latent Gain Btu/hr Occupants 2.0 Occupants X 200 Btuh/occ. = 400 Infiltration: 4,771 X 0.91 X 69.33 X 0.00490 = 1,475 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,8 5 Ene Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2012-05-09709:42:47 ID: Pa - e 29 of 33 C 17-4 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Kavas Residence 5/9/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Entry / Great Rm / Hall Outdoor Dry Bulb Temperature 111 OF Floor Area 1,594.0 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF Outdoor Daily Range: 34 OF O a ue Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof (VV) 1,594.0 X 0.0250 X 56.0 = 2,232 R-21 Wall (N) 367.5 X 0.0690 X 23.0 = 583 R-21 Wall (E) 200.0 X 0.0690 X 33.0 = 455 R-21 Wall (S) 75.0 X 0.0690 X 26.0 = 135 R-21 Wall 376.5 X 0.0690 X 33.0 = 857 X X X X X X X X Page Total 4,262 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr FxdWdw (125) (N) 0.0 X 20.3 + 12.5 X 20.3 = 254 FxdWdw (126) (N) 0.0 X 20.3 + 27.5 X 20.3 = 558 FxdWdw (127) (N) 0.0 X 20.3 + 27.5 X 20.3 = 558 SIdG1sDr(1G) (E) 220.0 X 19.9 + 0.0 X 36.5 = 4,376 SwngGIsDr (1A) (IM 1.6 X 16.3 + 34.4 X 32.9 = 1,158 FxdWdw (1A) (!M 4.6 X ' 20.3 + 43.4 X 41.7 = 1,902 FxdWdw (128) (IM 0.0 X 20.3 + 27.5 X 41.7 = 1,146 X + X X + X Page Total 9,954 Internal Gain Btu/hr Occupants 0.0 Occupants X 230 Btuh/occ. = 0 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.91 X 87.22 X 39 = 3,294 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,509 Latent Gain Btu/hr Occupants 0.0 Occupants X 200 Btuh/occ. = 0 Infiltration: 4,771 X 0.91 X 87.22 X 0.00490 _ 1,856 Air Sensible CFM ELA AW TOTAL HOURLY.LATENT HEAT GAIN FOR ROOM 1,856 Ene Pro 5.1 by EnerqySoft User Number: 3665 RunCode: 2012-05-09T09:42:47 ID: Page 30 of 33 Ah RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Kavas Residence 5/9/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Mst. Suite / Office Outdoor Dry Bulb Temperature 111 OF Floor Area 1,204.0 ft-- Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF, Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof 1,204.0 X 0.0250 X 56.0 = 1,686 R-21 Wall (N) 60.0 X 0.0690 X 23.0 = 95 R-21 Wall (E) 349.0 X 0.0690 X 33.0 = 795 R-21 Wall (S) 439.4 X ' 0.0690 X 26.0 = 788 R-21 Wall (W) 30.0 X 0.0690 X 33.0 = 68 X X = X X = X X = X X = Page Total 3,432 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr SwngGlsDr(1H) (E) 0.0 X 16.3 + 56.0 X 32.9 = 1,843 SwngGlsDr (1J) (E) 21.7 X 16.3 + 34.3 X 32.9 = 1,482 CsmtWdw (110) (S) 0.0 X 19.3 + 13.8 X 19.4 = 268 CsmtWdw (111) (S) 0.0 X 19.3 + 13.8 X 19.4 = 268 CsmtWdw (112) (S) 0.0 X 19.3 + 8.0 X 19.4 = 155 CsmtWdw (113) (S) 0.0 X 19.3 + 45.0 X 19.4 = 874 X + X - X + X = X + X = Page Total 4,889 Internal Gain, Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.91 X 65.88 X 39 = 2,488 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,039 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.91 X 65.88 X 0.00490 = 1,402 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,602 Ener Pro 5.1 by Ener Soft User Number. 3665 RunCode: 2012-05-09709:42:47 ID: Page 31 of 33 C, t ,i • • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Kavas Residence 5/9/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Bed #2 & 3 / Guest Suite Outdoor Dry Bulb Temperature 111 OF Floor Area 1,284.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF Outdoor Daily Range: 34 OF Oaaoue Surfaces R-38 Roof R-21 Wall R-21 Wall R-21 Wall R-21 Wall Orientation (E) (S) (M Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Area X X X X X X X. X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,458.0 0.0250 56.0 311.2 0.0690 23.0 144.0 0.0690 33.0 405.1 0.0690 26.0 450.0 0.0690 33.0 4.5 0.0 20.3 4.5 0.0 19.3 13.8 0.0 19.3 13.8 0.0 19.3 41.3 Page Total Fenestration CsmtWdw (124) SwngG/sDr (1K) CsmtWdw (114) CsmtWdw (115) FxdWdw (116) FxdWdw (117) CsmtWdw (118) CsmtWdw (119) CsmtWdw (120) Orientation (N) (E) (S) (S) (S) (S) (S) (S) (S) Shaded Area X X X X X X X X X GLF + + + + + + + + + Unshaded Area GLF X 19.3 X 32.9 X 19.4 X 19.4 X 20.4 X 20.4 X 19.4 X 19.4 X 19.4 Page Total = = = = = = = = = 0.0 19.3 13.8 0.0 16.3 56.0 0.0 19.3 13.8 0.0 19.3 13.8 0.0 20.3 4.5 0.0 20.3 4.5 0.0 19.3 13.8 0.0 19.3 13.8 0.0 19.3 41.3 Btu/hr 2, 041 494 1 4,6141 Btu/hr 267 1,843 268 268 92 92 268 268 802 4,167 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.91 X 70.26 X 39 = 2,653 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,158 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.91 X 70.26 X 0.00490 = 1,495 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 9 9451 n (% RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Kavas Residence 5/9/2012 M ROOM INFORMATION DESIGN CONDITIONS Room Name Bed #2 & 3 / Guest Suite Outdoor Dry Bulb Temperature 111 OF Floor Area 1,284.Oft-- Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr CsmtWdw (121) (S) 0.0 X 19.3 + 13.8 X 19.4 = 268 CsmtWdw (122) (S) 0.0 X 19.3 + 13.8 X 19.4 = 268 I CsmtWdw (123) (S) 0.0 X 19.3 + 13.8 X 19.4 = 268 X + X - X + X - X + X - X + X - X + X - X L + L X I - Page Total 804 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.91 X 70.26 X 39 = 2,653 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,158 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.91 X 70.26 X 0.00490 = 1,495 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,295 Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2012-05-09T09:42:47 ID: Page 33 of 33 • Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 5/9/2012 iA Electronically Signed at CalCERTS.com by Peter L Jacobs (Peter Jacobs Homes, Inc.) 5/10/2012 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Kavas Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/9/2012 Project Address Lot 222 - Hideaway La Quinfa California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,349 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ® Yes ❑ No HERS Measures -- If Yes, A CF=4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special F Construction Type Cavity ( Features see Part2 of 5 Status Roof Wood Framed Attic R-38 5,523 New Wall - Wood Framed R-21 4,268 A New Slab Unheated Slab -on -Grade None 5,349 Pe 5 ' FE ew . 0� CONS I FENESTRATION r U- erior Orientation Area(ft) SHGC Overhang Sidefins Shades Status Left (N) 11.3 M;..* 0:370 0.32 none none Bug Screen New ' Left (N) _ 22.5 `" 0 370 0 32 :. none , none . ,Bug Screen New ' Rear,(E)o r + ; 40.0 O340 0 36 none , , none} Bug Screens,, New' Rear E' _ 40:0- 0 340` 0 36 none r `�}� none �Bu Scr e M Rear E ' , 40 0 0 340' 036none� n net3u Screen New �' yK" .: ''�` FRT k:8 Right (S) 40:0 r 0 290 - .. Ory28>20 0� ,none _ r,y Bug Screen x'�'n: , ,amu- � �Y�.,� x� ¢ sa�•�•_ Right (S) '3 , 0 340 `.. 0 36 20 0 none Bug Screen. .. . New Right (S);, .. 18.0,b.340 0.36 20.0 none Bug Screen New Right (S) 27.5 -: 0.340 0.36 none none Bug Screen New Front (W)' "27:5 ; , 0.340 0.36 none none Bug Screen New Lek (N) 12.5:. 0.340 0.36 none none Bug Screen- New - K HVAC SYSTEMS Ot . -Heating.Min. Eff Cooling Min. Eff, Thermostat Status - 1 Split Heat Pump 8.50 HSPF Split Heat Pump 16.2 SEER Setback New 1 Split Heat Pump 8.50 HSPF Split Heat Pump 15.5 SEER Setback 'New ' 1 Split Heat Pump 8.50 HSPF Split Heat Pump 16.2 SEER Setback New • HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Zone #1 Ducted Ducted Conditioned 6.0 1 New Zone #2 Ducted ' Ducted Conditioned 6.0 New,` Zone #3 Ducted Ducted • Conditioned 6.0 New • WATER HEATING f Ot . Type Gallons Min. Eff Distribution ; Status 2 Large Gas 75 0.801 Kitchen Pipe Ins •New, EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2012-05-09709:42:47 ID: Pae 1 of 10 Reg: 212-N0021217B-000000000-0000 Registration Date/Time: 2012/04/30 11:13:50 HERS'Provider: CalCERTS, Inc Electronically Filed by Scott DeVoe and Authenticated at Ca10ERTS.cOm - 5/9/2012 T ::.Electronically Signed at CalCERTS.com by Peter L Jacobs (Peter Jacobs Homes, Inc.) 5/10/2012 ' 3 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name ' Kavas Residence Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration ' Date . 5/9/2012 Project Address Lot 222 - Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,349 Addition n/a # of Stories 9 FIELD INSPECTION -ENERGY CHECKLIST . El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status _ FENESTRATION -" U- Exterior �µ Orientation_: Area 1'Factor SHGC Overhang Sidef ins Shades Status Lett{N) 27.5 t�`, :0:340 0.36 none none 'Bug Screen New Left (N) ;. 27.5 ^ *. 0 340 0 36 ,, none ,;'^ , none Bug -Screen New .. a Rear E 220.0 0 480• b b 28 16 0 n none'y Bu 'Screen " New Front (1A0,� 36Oy �0 290' 0 283 0 noneF �Bug.Scr en ;�"" New LLc.' K Front (N0 X48:0 0 340 .: 036 "3 0 none Bu Screen $ R New 4 _� 9 ��"f:: .', . Front (W) 27.5 0 340:'' -0 36nonen� nonea„�=Bug Screen �? New Rear P. 56.0 0 290 Z. 0:289.none :none Bug Screen New Rear (E) 56.0 0.290 0.28 4.0 none Bug Screen - New Right (S) 13.8 : 0.370 0.32 none none -' Bug Screen New Right (S) 13.8 '- v: 0.370 0.32' none none Bug Screen New ' Right (S) 8.0.', t: 0.370 0.32 none none Bug Screen New ' HVAC SYSTEMS T Qty. Heating Min. Eff Cooling Min. Eff Thermostat , Status 1 Split Heat Pump 8.50 HSPF Split Heat Pump 16.2 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Zone #4 Ducted Ducted Conditioned 6.0 New WATER HEATING ` Ot . Type Gallons Min. Eff. Distribution Status EnergyPro 5.1 by EnergySoft User Number. 3665 RunCode: 2012-05-09709:42:47• ID: Page 2 of 10 Reg: 212-N0021217B-000000000-0000 Registration Date/Time:, 2012/04/3011:13:50 HERS, Provider: CalCERTS, Inc , Electronically Filed by Scott DeVoe and Authenticated at Ca10ERTS.com - 5/9/2012 ;. Electronically Signed at CalCERTS.com by Peter L Jacobs (Peter Jacobs Homes, Inc.) 5/10/2012 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Kavas Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/9/2012 Project Address Lot 222 - Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,349 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATIONU- Exterior Orientation. Area(ft) . Factor SHGC Overhang Sidefins Shades Status Right (S) 45.0. 0.370 0.32 none none Bug Screen New r :.. Left (N) 13.8 0 370„ 0 32 :none ,. s, none Bug -Screen New Rear (E) r 56.0 0 290.-' 0 28 none , .;1- none „' Bug Screen New Right (S) - 13.8 0 370 0.32` none r§ =none , Bug Screen New Right(s);,-x: i �' 13:8 ; f, 0 370' 0i32 32 -,-none u Ynone Bug,Scieen � ;;New " Right (S) ~ . {: 4,5 0 340__ ` l 0 36 `' none none - V Bug Screen New; Right (S) 4.5 0 340` 0.36 none none Bug Screen. New Right (S) 13.8 0.370 0.32 none none Bug Screen New Right (S) 13.8 0.370 0.32 none none Bug Screen New Right (S) 41.3 - 0.370 0.32 none none Bug Screen New Right (S) 13.8: 0.370 0.32 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2012-05-09T09:42:47 ID: Page 3 of 10 Reg: 212-N0021217B-000000000-0000 Registration Date/Time: 2012/04/30 11:13:50 HERS Provider: Ca10ERTS, Inc Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 5/9/2012 i Electronically Signed at CalCERTS.com by Peter L Jacobs (Peter Jacobs Homes, Inc.) 5/10/2012 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Kavas Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date - 5/9/2012 Project Address Lot 222'- Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,349 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ® Yes ' ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. " ❑ Yes ❑ No Special Features"-- If Yes, see Part 2 of 5 of this form for details. 4 - INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- _ Exterior Orientation::,::: Area(ft) Factor SHGC Overhang Sidefins Shades Status Right (S) `" " 13.8 0.370 0.32 none none Bug Screen New Right (S) 13.8 : b 0.370' ,0 32 none:,, '" - ngne ,B,ugSereen�; ' , New • ...,.. r p F • • ;+� yv v. t�� � 1` .... '^ ti. �I: R 1 k ! iAl f �X?t^?:V' i y HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number. 3665 RunCode: 2012-05-09T09:42:47 ID: Page 4 of 10 Reg: 212-N0021217B-000000000-0000 Registration Date/Time: 2012/04/30 11:13:50 HERS Provider: CalCERTS, inc Electronically Filed by Scott Devoe and Authenticated at CalCERTS.com - 5/9/2012 i Electronically Signed at CalCERTS.com by Peter L Jacobs (Peter Jacobs Homes, Inc.) 5/10/2012 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Kavas Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/9/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford White 75 Gal is a non-NAECA large storage gas water heater. Verify DHW details. HERS REQUIRED VERIFICATION, - M Items in this-secfion require field;•testing and/or venficaUori by a certified'HERS Rater: The inspector4must red `iVe a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System -Lennox XP16/CBX32MV (4 Ton) includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation'of the correct.Condenser The HVAC System Zone #1 has Ducts; Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit -.and all Ducts and Plenums. The HVAC System Zone #1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria.. . The Cooling System Lennox XP16/CBX32MV (5 Ton) includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System Zone #2 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Lennox XP16/CBX32MV (4 Ton) includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System Zone #3 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Lennox XP16/CBX32MV (4 Ton) includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System Zone #4 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro 5.1 by Ene Soft User Number. 3665 RunCode: 2012-05-09709:42:47 ID: Page 5 of 10 Reg: 212-N0021217B-000000000-0000 Registration Date/Time: 2012/04/30 11:13:50 HERS Provider: CalCERTS, Inc i Electronically Filed by Scott Devoe and Authenticated at CalCERTS.com - 5/9/2012 i Electronically Signed at CalCERTS.com by Peter L Jacobs (Peter Jacobs Homes, Inc.) 5/10/2012 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) C 7 R Project Name Building Type m Single Family ❑ Addition Alone Date Kavas Residence. ❑ Multi Family ❑ Existing+ Addition/Alteration 5/9/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r 'Space Heating 4.28 2.58 1.70 Space Cooling 52.14 48.72 3.43 Fans 10.27 14.24 , -3.97 Domestic Hot Water 6.82 4.69 2.13 Pumps 0.00 .0.00 0.00 Totals 73.52 70.23 3.28 Percent Better Than Standard: 4.5 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration _ Building Front Orientation: (K9 270 deg Ext. Walls/Roof Wall Area' Area Number of Dwelling Units: 1.00 1,086 _ - 139 Fuel Available at Site: 'Natural Gas (N) 1,441 r 115 Raised Floor Area: 0. (E) 1,421; 508 Slab on Grade Area: 5,349 ` (S) 1,427 - ' . 345' Average Ceiling Height:;. = 11.1 Roof 5,523 0 ' • Fenestration Average U -Factor: 0.36 TOTAL: 1,107 Average, SHGC: 0.32 Fenestration/CFA Ratio: 20.7% - REMARKS: "��A .CYC +wn a t ; .:�.,F '•.'p N g :k- „[ �,� r � .,� '�+� { . f Vq xF. �'3. : i`^.•.' n,m• F k ' -177. E 9tr � :i 2*� M 1 )' .�� ��( +R°t� '"Tny'9.+`T +,..)^,BF t:.. y. i'v.� � v.G �� •3l!` 5'.L , - - �, 4 STATEMENT'OFCOMPLIANCE This certificate of. compliance lists the building features and specifications needed to comply with Title 24; Parts 1=the Administrative Regulations and Part 6 the - Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. - Documentation Author Company -. BREEZE AIR CONDITIONING ' 5/9/2012 e Address 75-145 St. Charles Place Name, Scott DeVoe , City/State/Zip Palm Desert, CA 92211 Phone (760) 346-0855 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the'specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using•duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and'certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) r' Company Helton DeFord & Assoc. Address 1261 N. Big Springs St. Name ! City/State/Zip Anaheim Hills, CA 92807 Phone (909) 957-4550 Signed License # Date Ener Pro 5.1 by EnemySoft User Number. • 3665 RunCode: 2012-05-09T09:42:47 ID: Pa - e 6 of 10 Reg: 212-N0021217B-000000000-0000 Registration Date/Time: 2012/04/30 11:13:50 HERS Provider: CalCERTS, Inc a Electronically Filed by Scott DeVice and Authenticated at CalCERTS.com = 5/9/2012 v Electronically Signed at Ca10ERTS.com"by Peter L Jacobs (Peter Jacobs Homes, Inc.) 5/10/2012 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 Project Name Kavas Residence Building Type m Single Family ❑Addition Alone -. - ❑ Multi Family' ❑ Existing+ Addition/Alteration Date. . , 5/9/2012' OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavit Exterior Frame Interior Frame •Azm Tilt Status 4 'Location/Comments Roof 1,267 0.025 R-38 • 270 0 New 4.2.1-A21 Zone #1 Wall 587 0.069 R-21 0 90 New 4.3.1-A6 Zone #1 Wall 220 0.069 R-21 - 90 90 New 4.3.1-A6 Zone 01 Wall 163 0.069 R-21 180 90 New T 4.3.1-A6 Zone #1 Wall 91 0.069 R-21 270 90 New 4.3.1-A6 Zone #1 Slab 1,267 0.730 None 0 180 New 4.4.7-A1 Zone #1 Roof 1,594 0.025 R-38 270 0 New 4.2.1-A21. Zone #2 Wall 368 0.069 R-21 0 90 New 4.3.1-A6 Zone #2 _ Wall 200 0.069 R-21 90 90 New 4.3.1-A6 Zone #2 Wall 75 0.069 R-21 180 90 New 4.3.1-A6 Zone #2' Wall 377 0.069 R-21 270 90 New 4.3.1-A6 Zone #2.. ` Slab 1,594 0.730 None 0 180 New 4.4.7-A1 Zone #2 - Roof 1,204 0.025 R-38 270 .0 New 4.2.1-A21 - 'Zone #3 Wall 60 0.069 R-21 0 •90 New 4.3.1-A6 Zone #3 Wall 349 0.069 R-21 90 90 New 4.3.1-A6 Zone #3 t Wall 439 0.069 R-21 180 90 New 4.3.1-A6 Zone #3 FENESTRATION SURFACE DETAILS ID T e Area . LI -Factor' SHGC Azm Status GlazingType Location/Comments .. 1 Window 11.3. 0.370 NFRC . 0.32 NFRC 0 New Wd Clad Lo/E (Csmt) (105) Zone #1 2; Window 22.5 ' 0.370 NFRC 0.32 NFRC 0 New Wd Clad Lo/E (Csmt) (106) Zone #1 3.' Window- 40.0 0.:N0 NFRC. 0.36 NFRC 90 New Wd Clad Lo/E (Fxd) 107) Zone #1' Window: ,: '" <: 40:0 0.340 NFRC :: 0.36 NFRC 90 New Wd Clad Lo/E (Fxd) (108) Zone #1 5 Window, 40.0 0.340 NFRC >,, :: 0;36 NFRC ; .,,, __90 New ;, y-..,_ .Wd Clad Lo/E (Fxd) (109) Zcne #1 6 Window: ',N40.0 40.0 0.290 NFRC 028 ,NFRC �• 100 Newt Wd,Clad Lo/E (Swing Dr),(1F) ,'Zane #1 7- Window ' .. ''_32:0 0.340 NF. RC f 0.36 'NFRC ° 17 180 Ne"w,, Wd:Clad Lo/E (Fxd) (1f) _Zone #1: 8 .Window" 18 0 X 0' 340 NFRC' t- 0.36 NFf CC- 180 Newer 'Wd, Clad Lo/E'(Fxd) (1 F) `, Zone #1 ^^ 9 Window' 275 X0;340 "NFRC 0.36 NFRC.>, "1'80 New 'Wd Clad Lo/E:'(Fxd) (100); Zone;.#1n; 10 • Window .,j275. 0:340 NFRC" :,.0.36 NFRC,:. 270 New 11- Window*W. h 12 5 :0:340 NFRC}; ^ X0.36 'NFRC � 6. New °"M. aNd;.Clad Lo/E'(Fxd) X125) , <I 12 .. Window. ;': 27.5..'0'340 NFRC �', ' =0;36 NFRC ' �-'0 'Ndiivt' Wd Clad Lo/E (Fxd) (1 Z6) Zone #2 13.. Window 27.5: 0:340 NFRC 0.36 NFRC' 0 New Wd Clad Lo/E (Fxd) 127 Zone #2 14;:. Windows~' G n220.0 0.480 NFRC ` 0.28 NFRC 90 New Wd Clad Lo/E (SGD) (1 G) Zone #2 15 Window '. 36:0 '0.290 NFRC • 0.28 NFRC 270 New Wd Clad Lo/E (Swng Dr) (1A), Zone #2 16' Window'.:- 48.0 :;:0:340 NFRC 0.36 NFRC 270 New Wd Clad Lo/E (Fxd) (1A) Zone #2 (1) LI -Factor Type: 116-A.7, Default Table from Standards, NFRC = Labeled Value - 2 SHGC Type: 116-B =Default Table from Standards, NFRC =Labeled Value EXTERIOR SHADING DETAILS' ID Window Ove hang - Left Fin Right Fin Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len Hat-_ Dist Len H t 1- Bug Screen 0.76 2 Bug Screen 0.76 . 3 Bug Screen i 0.76 4 Bug Screen 0.76 -5 Bug Screen -0.76 6 Bug Screen 0.76 8.0 5.0 20.0 '2.0 20.0 20.0 7 Bug Screen 0.76 8.0 4.0 20.0 2.0 20.0 -20.0 ' 8 Bug Screen 0.76 2.0 9.0 20.0 0.1 20.0 20.0 9 Bu Screen 0.76 10 Bu Screen 0.76 11 Bu Screen -0.76 12 Bug Screen 0.76 13 Bu Screen . 0.76 14 Bug Screen 0.76 10.0. 22.0 16.0 2.0 16.0 16.0 15 Bug Screen . 0.76 9.0 4.0 3.0 2.0 3.0 3.0 - 16 Bug Screen 0.76 24.0 2.0 3.0 0.1 3.0 3.0 Ene Pro 5.1 b Ene Soft User Number., 3665 RunCode: 2012-05-09709:42:47 ID: -Page 7 of 10 CF -1 R - i Reg: 212-N0021217B-000000000 0000 -Registration Date/Time: 2012/04/30 11:13:50 HERS Provider: CalCERTS,'•Inc 71. Electronically Filed by Scott DeVoe and Adthenticated at CalCERTS.com - 5/9/2012 Electronically Signed at Ca10ERTS.com by Peter L Jacobs (Peter Jacobs Homes, Inc.) -5/10/2012 1 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 -CF-1 R Project Name Kavas Residence Building Type 0 Single Family " ❑ Addition Alone ' . ❑ Multi Family ' ❑ Existing+ Addition./Alteration Date - 5/9/2012' OPAQUE SURFACE DETAILS Surface. U- Insulation Joint Appendix Type, Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall _ 30 0.069 R-21 270 90 New 4.3.1-A6 Zone #3 Slab 1,204 0.730 None 0 180 New 4.4.7-A1 Zone #3 Roof 1,458 0.025 R-38 270 0 New 4.2.1-A21 Zone #4 Wall 3111 0.069 R-21 _. 0 90 New 4.3.1=A6 Zone #4 Wall 144 0.069 R-21, 90 90 New 4.3.1-A6 Zone #4 Wall 405 0.069 R-21 ,180 - 90 New . 4.3.1-A6 Zone #4 Wall 450 0.069 R-21 270 90 New 4.3.1-A6 Zone #4 ` Slab .1,284 0.730 None = 0 180 New 4.4.7-A1• Zone #4 FENESTRATION SURFACE., DETAILS ID Type Area U -Factor SHGC Azm Status 'Glazing Type Location/Comments 17 Window 27.5 ' 0.340 'NFRC 0.36 NFRC 270 New Wd Clad Lo/E (Fxd) (128) Zone #2 18;. Window : '56.0 "0.290 NFRC 0.28 NFRC 90 New Wd Clad Lo/E (Swng Dr) (1H) Zone #3 19 . Window,% .<' - 56.0: 0.290 NFRC' 0.28 NFRC 90 New Wd Clad Lo/E (Swng Dr (1J) Zone #3 t .. .20 Window;..: 13.8 0.370 'NFRC:. , 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) (I 10) Zone #3 21 :_ Window._. 13.8 0.370 NFRC _., __ 0,32, NFRC.__..__..__ _180 New_Wd Clad Lo/E (Csmt) (111).,,,;,.,_:, Zone #3 L. 22: Window,' ', X8:0 0.370 NF.,-RC�,�0.32 NFRC4 i8p New f ,lNd Clad Lo/E`(Csmf)'(141,2) `; `Zone #3 a 23 ' Wirid6W.!A- '445.0 0.370 ,NFRC it , '"0.32 WFRCr' ,' 1�54 80 NdW,;WdClad L`o/E:'(Csmt)'(113) _,.' Zone #3 24 'Window 13.8,-Z0.370, NFRCI-`, ;' 0.32 NFRC ';; . 0 New, `Wd Clad L&E'(Csmt) (124)'&Zone;#4 25 Window: 5610 X0290. NFRC 0.28 NFRC A ";80 New; ';Wd Clad Lo/E Swn Dr 1K Zone<#4 26 Window 4- , 1- 8 f0.370 NFRC .. 0.32' NFRC 180 'NewK Wd;Glad Lo/E (Csmt).(1,14), Zone"#4 27 : Window;,13 8 X0:370 NFRC,, *>.e 0.32: NFRC X180 ;New lNd:.Cladao/E (Csmt),'::115) � Zone28- Window' -4.5 '" 0:340 NFRC -' 1VE 0.3& NFRC �,t?' "yeN180 New _ "°' ;` Wd Clad Lo/E'(Fxd) (I 16)Zone #4 - 29' Window - 4.5 .. 0.340 NFRC 0.36 NFRC180 New Wd Clad Lo/E (Fxd) (117)- ' Zone #4 30; Window A•:13.8 0.370 NFRC" 0.32 NFRC 180 New Wd Clad Lo/E (Csmo (118) Zone #4 +. Window 13:8 .0.370 NFRC: 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) (119) Zone #4 32' Window 41.3 ', 0.370 NFRC 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) (120) Zone #4 (1) U -Factor Type:` 116-A'= Default Table from Standards, NFRC = Labeled Value 2 `SHGC T e: 116-B =Default Table from Standards, NFRC =Labeled Value EXTERIOR SHADING DETAILS' - Window Ove hang "' Left Fin Right Fin ID Exterior Shade Type SHGC Hat Wd Len H t LExt RExt Dist .Len ^ _ H t Dist • Len H t 17 Bug Screen 0.76 - 18 Bug Screen 0.76 » 19 Bug Screen 0.76 '8.0 7.0 4.0 0.1 4.0 4.0 _ } 20 JBug Screen 0.76 21 . Bug Screen. 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 : - 24 Bug Screen 0.76 25 Bug Screen 26 Bug Screen 0.76 ` 27 Bug Screen 0.76 28 Bug Screen 0.76 - 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2012-05-09709:42:47 ID: Page 8 of 10 Reg: 212-N0021217B-000000000-0000 Registration Date/Time:,2012/04/30 11:13:50 HERS Provider: CalCERTS, inc ' y i Electronically Filed by Scott DeVoe and Authenticated at Ca10ERTS.com - 5/9/2012 Electronically Signed at CalCERTS.com by Peter L Jacobs (Peter Jacobs Homes, Inc.) 5/10/2012 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 C -1 R Project Name Kavas Residence Building Type m Single Family ❑Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/9/2012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area [Factor Cavi Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status GlazingType Location/Comments 33 Window 13.8 0.370 NFRC 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) (121) Zone #4 34; Window. 13.8 ' .0.370 NFRC. 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) (122) Zone #4 35 Window-- 13.8 0.370 NFRC 0.32 NFRC 180 New Wd Clad Lo/E (Csmt) 123 Zone #4 - �.. v j z _ ry +P�S�4.0 .5�• 3M'wi � 3 ��#$' ! R`i �'.� '�. . .�"i.. ;4 ri� hT �. �'vG a.=- _ �.-.7M: ka :7k' ,i4 ..+e4...-'�.3.�'. .Y�. ,!�aF'IKf x:^ :-.i +,�'Ati{,�.. .:._` F 'g4c�,i wi n�..'r, -; `- �'� $%!' gib: ti' -w .ir+'S'. ; ., Y [k," ; 141, (1) Ll -Factor Type: 116-A;- Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-8 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin - ID Exterior Shade Type SHGC H t Wd Len H t LExt REA Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 s Ener Pro 5.1 by Ener Sok User Number: 3665 RunCode: 2012-05-09709:42:47 ID: Page 9 of 10 Reg: 212-N0021217B-000000000-0000 Registration Date/Time: 2012/04/30 11:13:50 HERS Provider:'Ca10ERTS, Inc Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 5/9/2012 .� Electronically Signed at CalCERTS.com by Peter L Jacobs (Peter Jacobs Homes, Inc.) 5/10/2012 + CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Kavas Residence Building Type ® Single Family ❑ Addition Alone , ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/9/2012 BUILDING ZONE INFORMATION .System Name Floor Area Zone Name New Existing Altered Removed Volume Year Built Zone#1 Kitchen/Family 1,267 13,937 - Zone #2 Entry / Great Rm / Hall 1,594 - 19,128 Zone #3 Mst. Suite/ Office 1,204 13,244 Zone #4 Bed #2 & 3/Guest Suite 1,284 12,840 Totals 5,349 0 0 0 HVAC SYSTEMS ? . :• S stem Name:,' QtY'''I Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Zone #1;.!.,1 ? Split Heat Pump 8.50 HSPF Split Heat Pump 16.2 SEER Setback New Zone #2 1 ` Split Heat Pump 8.50 HSPF Split Heat Pump 15.5 SEER Setback New Zone #3. r 1;Split Heat Pwrip �8s50°HSPFSplitHeat-Pump, .: , ,16.2�SEER2 Settiack- :. New Zone #4,.,:, x4 r"r P � 1 v Spbt'Heaf Pum .. 8.50 HSPF+ Sp1i Heat Pump -_• it:,,40.2 SEER ,Setback'¢ : . _ ., New baa : ` 1 '""� ,•">t ., €"' - ' " � E`r,,1. ,►R • �:' „ � ''� '` �Y' k��3°i' ";a ; Tk �.a"rA �„x'S. ems. '�� ` +�'.3'-=� �i••< ,.�'�` HVAC•`.DISTRIBUTION 1'4", '- '. � ' �.__ ` � " � . �i 6 Duct t_ Ducts System Name � " ' ". .H6ati - :' .Coolm Duc Locators R Value Tested? Status Zone#1 -" Ducted:} Ducted Conditioned 6.0 m New Zone #2 �ti Ducted,. Ducted Conditioned 6.0 m New Zone #3 Ducted.; Ducted Conditioned 6.0 0 New Zone #4Ducted Ducted Conditioned 6.0 m . New • ❑ WATER HEATING SYSTEMS f S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford White 75 Gal 2 Large Gas Kitchen Pipe Ins 76,000 75 0.80 0.00% , n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING _ Control Hot Water Piping Length ft 0 v N Q System Name i '� Pipe Length Pipe Diameter Insul. Thick. aty. HP Plenum Outside Buried 13 _ ❑ t ❑ ; 01 Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2012-05-09709:42:47 ID: Pae 10 of 10 Reg: 212-N0021217B-000000000±0000 Registration Date/Time! 2012/04/30 11:13:50 HERS Provider: CalCERTS, Inc' ' i Sladden Engineering 45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avcnuc, Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Dcuumunt, CA 92223 (951) 845-7743 Fax (951) 845.8863 800 E. Florida Avenue. Hemet, CA 92543 (951) 766-8777 Fax (951) 766-8778 December 29, 2011 Project No, 544-11226 11-12-289 Peter Jacobs Homes P. p, Box 356 La Quinta, California 92247 Project: Proposed Custom Residence Lot 222 - The Hideaway La Quinta, California Subject: Geotechnical Update Ref: Geotechnical Engineering Report prepared by Earth Systems Southwest (ESS) dated April 11, 2001; File No, 08199-01, Report No. 04-04-718. Report of Testing and Observation During Rough Grading prepared by ESS dated August 28, 2002; File No. 07117-11, Report No. 01-07-718 Report of Testing and Observations During Rough Grading prepared by Sladden Engineering dated October 12, 2003; Project No. 544-2199 Report No. 03-10.647 As requested, we have reviewed the above referenced geotechnical reports as they relate to the design and construction of the proposed custom residence. The project site is located on 'Lot 222 within the Hideaway Golf Club development in the City of La Quinta, California. It is our understanding that the proposed residence will be a relatively lightweight wood -frame structure supported by conventional shallow spread footings and concrete slabs on grade. The subject lot was previously graded during the rough grading of the Hideaway project site and " was subsequently regraded. The rough grading included over -excavation of the native surface soil along with the placement of engineered fill soil to construct the building pads. The regrading included processing the surface soil along with minor cuts and fills to construct the individual building pads to the current configurations. Some additional over -excavation was performed in areas where the building envelopes were reconfigured. The most recent site grading is summarized in the referenced Report of Testing and Observations During Rough. Grading prepared by Sladden Engineering along with the compaction test results. The referenced reports include recommendations pertaining to the construction of residential structure foundations. Based upon our review of the referenced reports, it is our opinion that the . structural values included in the referenced grading report prepared by Sladden Engineering remain applicable for the design. and construction of the proposed residential structure " foundations. MAR 20 2012 BY: k 'A December 29, 2011 -2- Project No. 544.1.1226 11-12-289 Because the lot has been previously rough graded, the remedial grading required at this time should be minimal provided that the building falls within the previously assumed building envelope. The building area should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted to a minimum of 90 percent relative compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. The allowable bearing pressures recommended in the referenced grading report prepared by Sladden Engineering, remain applicable for use in the design of the proposed residence. Conventional shallow spread footings should be bottomed into properly compacted engineered fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be utilized if desired. The maximum allowable bearing pressure should bc-3000 psf. The recommended allowable bearing pressures may be increased by one-third for wind and seismic loading. I Lateral forces may be resisted by friction along the base of the foundations and passive resistance along the sides of the footings. A friction coefficient of 0.50 times the normal dead load forces is recommended for use in design. Passive resistance may be estimated using an equivalent fluid weight of 300 pcf. If used in combination with the passive resistance, the frictional resistance should be reduced by one third to 0.33 times the normal dead load forces, The bearing soil is non -expansive and falls within the "very low" expansion category in accordance with 201.0 California Building Code (CBC) classification criteria. Slab thickness and reinforcement should be determined by the structural engineer, we recommend a minimum floor slab thickness of 4.0 inches. All slab reinforcement should be supported on concrete chairs to ensure that reinforcement is placed at slab mid -height. Slabs with moisture sensitive surfaces should be underlain with a moisture vapor retarder consisting; of. 10 -mil Visqueen, or equivalent. All laps within the membrane should be sealed and at least 2 inches of clean sand should be placed over the membrane to promote uniform curing of the concrete. To reduce the potential for punctures, the membrane should be placed on *a pad surface that has been graded smooth without any sharp protrusions. If a smooth surface can not be achieved by grading, consideration should be given to placing a 1 -inch thick leveling; course of sand across the pad surface prior to placement of the membrane. Based on our field observations and understanding of local geologic conditions, the soil profile type judged applicable to this site is, So, generally described as stiff soil. The following presents additional coefficients and factors relevant to seismic mitigation for new construction based upon the 2010 California Building Code (CBC). i f i i Sladden Engineering i December 29, 2011 -3- Project No. 544-11226 11-12-289 The seismic design category for a structure may be determined in accordance with Section 1613 of the 2010 CBC or ASCE7. According to the 2010 CBC, Site Class D may be used to estimate design seismic loading for, the proposed structures. 'Che period of the structures should be less than 'A second. This assumption should be verified by the project structural engineer. The 2010 CBC Seismic Design Parameters are summarized on the following page. Occupancy Category (Table 1604.5): II Site Class (Table 1613.5.2): D Ss (Figure 1613.5.1):1.508 St (Figure 1613,5.1):0.60g Fa (Table 1613.5.3(1)):1.0 FY (Table 1613.5.3(2)):1.5 Sm (Equation 1.6-36 (Fa X Ss)), 1.50g Sm1 (Equation 1.6-371F„ X Si)): 0.908 SDS (Equation 16-3812/3 X Sms)):1.00g SD1(Equation 16-39 12/3 X Sm1)): 0.608 Seismic Design Category D If you have questions regarding this letter or the referenced reports, please contact the undersigned. Respectfully submitted, SLA1DDEN ENGINEERIN ES Brett L. Ander Principal Engineer tda C A SER/gl x.04 CAl1;aQ�\Q Copies: Q Peter Jacobs Homes Siadden Engineering WEDDLE SURVEYING MAPPING, INC.-. Boundary -Construction • Topographic ;Aerial Surveys--ALTA-Surveys • GPS- Consulting • ' _ November 21,-2012 Mr. Timothy R. Jonas'son Public Works Director /.City Engineer City of La Quinta- - 78-495 Calle Tampico La Quinta, CA _92253-1504 Re: Pad/Form Grade Verification. e - - City of La Quinta KAVAYIOTIDIS "KAVAS RESIDENCE Lot 222 Tract No. 29894.-2 Amnd. - 53-607 Via Palacio - - HIDEAWAY _ APN 777-220-008 -- i ..;,•' Dear Mr. Jonasson: We have performed a field survey to determine the vertical location of the Building Pad and ' Building Form for the above referenced project., The elevations observed are as follows: PAD (DESIGN) - PAD (AS -BUILT) 1010.5'- r ._� ! 1010.45' ' FORM (DESIGN) j FORM (AS --BUILT) ' 4 1011.17' - -- 1011.17' - - _ 4. 'These field observations are in substantial conformance with the Precise Grading Plan prepared. by ESSI SHAHANDEH, CIVIL ENGINEER, dated 10/12/2012; approved by the City of La _ Quinta Building & Safety Department and the building horizontal location substantially conforms _ to the required setbacks and site layout as shown on the approved site plana Sincerely _+ .- �O \,AND S�j WEDDLE SURVEYING MAPPING, INC _ 4 O No. 5570m Exp. 09-30-191 David L. Weddle, President L.S. 5570, exp 09/30/13 y Yz 9TFOFCA�\F�� { P.O. Box 10418 • Palm Desert, CA 92255-0418 77-725 Enfield Lane, -Ste. 140 • Palm Desert, CA 92211 • 760.360.5570 A _ E -Mail: WedSury@aol.com •,Fax 760.360.55 73 ' '