Loading...
11-0937 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: _�I1-00000-9371 ------------------------------'----------------— WORKER'S COMPENSATION DECLARATION Property Add"ri §s 53-672--VIA"PALACIO APN: 772-560-054-• - - Application description: - DWELLING - SINGLE-FAMILY. DETACHED Property Zoning: LOW DENSITY RESIDENTIAL- ESIDENTIAL-Application Applicationvaluation: 430810 Applicant: Architect or Engineer: Owner: AMES, LEE 77-_726. VIA VENITO LA QUINTA, CA -92253-9221 Contractor: SUN VISTA DEVELOPMENT P.O. BOX 1144 LA QUINTA, CA 92247 (760)771-4722 Lic. No.: 744091 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 12/01/11 Gl7Y oc A :%,"W(A -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION ------------------------------'----------------— WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: - Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.- I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: B License No.: 744091 - _ for by Section 3700 of the Labor'Code, for the performance of the work for which this permit is issued. , v Date Contractor: V _ I_ have and will maintain workers' compensation insurance, asrequired by Section 3700 of the Labor . - Code, for the performance of the work for which this permit is issued.. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier STATE FUND Policy Number 0000179-2010 following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or.she is licensed pursuant to the provisions of the Contractor's State - and agree that, if I should become subject to the workers' compensation provisions of Section .License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or. that he or.she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by 3700 of the Labor Code, I shall forthwith comply with those provisions. /, /at,(,.24 �4pplicant: any applicant for a permit subjects the applicant to a'civil penalty of not more than five hundred dollars ($500).: 4Ntl (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and - the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION CO.VERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her bwn employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES,AS PROVIDED FOR IN improvements are not intended or.offered for sale. If, however; the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES., one year of completion, the owner -builder will have the burden of proving that he or she did not build or *improve for the purpose of sale.). ( 1 1, as owner of the property, am exclusively contracting with .licensed contractors to construct the project (Sec. 7044, business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). am exempt under Sec. , BAP.C. for this reason Date: Owner: . CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERA11T APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend,indemnify and hold harmless the'City of La Quinta, its officers, agents and employees for any act or omission related to the work being ., performed under or following issuance of this permit. 2. Any permitissued as a result of thi's..application becomes null and void if work is not commenced within 180 days from date- of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for i5spection purposes. 16ate:�y/Signature (Applicant or Agent): �i� Application Number 11-00000937 " Structure Information Construction Type . . . . . TYPE V, UNPROTECTED Occupancy -Type . . DWELLG/LODGING/LONG <=10 Other struct info CODE EDITION 2010 # BEDROOMS 4.00 FIRE SPRINKLERS'' YES - GARAGE SQ FTG 979.00 PATIO SQ FTG .1254,00 NUMBER OF"'UNITS .1.00 1ST FLOOR SQUARE .FOOTAGE 4766.00 PermitBUILDING PERMIT Additional.desc . 'Permit Fee: 1626.50 Plan .Check Fee 1057.23,• Issue Date Valuation. 381052 Expiration Date 5"/29/12 - Qty Unit Charge Per Extension BASE FEE 639.50 282,.00. 3,.5000 THOU. BLDG 10,0;001-500,000 987.00 Permit ELEC-NEW RESIDENTIAL Additional desc ✓ Permit Fee 241.47 Plan Check Fee 60.37' Issue Date. Valuation 0 Expiration Date 5/29/12 Qty Unit Charge Per Extension BASE FEE 15.00. 4766.00 .0350 ELEC NEW RES - 1"OR 2 FAMI°LY 166.81 2233.00 .0200 ELEC-GARAGE-OR NON-RESIDENTIAL 44.66 1..00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit GRADING -PERMIT ' Additional desc . Permit Fee 15.00 Plan Check Fee .00 Issue Date . . . Valuation .0 Expiration Date ., 5/29/12 Qty Unit.Charge Per Extension BASE FEE 15.00 Permit . . . .-. MECHANICAL ..LQPERMIT Application Number 11-0000093.7 Permit MECHANICAL Additional desc . 'Permit Fee 194.00- Plan Check -Fee 48.50 Issue Date . Valuation, 0` _ Expiration Date 5/29/12. , Qty .Unit Charge Per Extension _ --- _.. --- - - - - - - -- -- -BASE FEE-' - - - --,- - ---15: 00 - -- - - - - - - _ 2.00 9.0000 EA -MECH FURNACE <=100K 18.00 2.00 11.0000 EA' MECH FURNACE >100K, 22..00 2:00 9.0000*EA MECH B/C'<=3HP/100K BTU 18.00 • 3.00 16.5000 EA MECH B/C >3-15HP/>100K-500KB.TU 49.50. 10.00 6.5000•EA MECH VENT FAN 65,00 1.00 6.5000 EA MECH EXHAUST -HOOD 6.50 Permit PLUMBING Additional desc . Permit Fee 222.75 Plan Check Fee 55.69 Issue Date Valuation 0 Expiration Date .. 5/29/12 • Qty Unit 'Charge Per Extension BASE FEE 15.00 24.00 6.0000 EA' PLB FIXTURE 144.00 . ` 1.'00. -15.0000-EA PLB BUILDING SEWER 15.00 1,.00 6.0000 EA PLB ROOF DRAIN 6.00 1:,00 7:5000 EA PLB WATER HEATER/VENT. 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00. 1:00 9..0000 EA PLB LAWN SPRINKLER SYSTEM. 9.00 11,00' .7500 EA PLB GAS PIPE >.=5, 8.25 r . '1.00 15.0000 EA PLB GAS METER 15.00 Special Notes and Comments 4766. SF SFD. R-3 OCCUPANCY, TYPE V -B CONSTRUCTION W/.FIRE SPRINKLERS... 2010 CODES.**PERMIT DOES NOT INCLUDE -BLOCK WALLS; FENCES, SWIMMING POOLS,'SPA, BBQ'S-and DRIVEWAY APPROACH** 2008 DIF. ARCHITECT DAVID HELTON C-32640 Other.Fees ART IN PUBLIC PLACES -RES 577.03 BLDG STDS ADMIN (SB1473) 18.00 - DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE-. 105.72 DIF FIRE'PROTECTION=RES •140.00 DIF LIBRARIES - RES 355.00 ' LQPLRN•IIT Application. Number 11-00000937 Other Fees MULTI -SPECIES FEE.." ­ 1254.00 DIF PARK MAINT' FAC - RES" 22 .'00 DIF"PARKS/REC - RES 892.00 - STRONG MOTION (SMI) - RES 43.08 DIF "STREET MAINT FAC -RES 67..00• DIF TRANSPORTATION - RES 1930.00 Fee summary Charged.; Paid Credited Due „.: Permit :Fee"Total 2299.72 .00 .00- 2299.72 Plan Check Total" 1221.79 750.00 .00 47i".79 Other Fee Total 6472.-83 •.00 .00 6472.83, Grand Total 9994.34 750.00. 00 9244.34 LQPER1IIT P.O. BOX 1504 APPLICATION ONLY Building 78-495 CALLE TAMPICO Address {� J Gl G) �G% LA QUINTA, CALIFORNIA 92253 Owner % � d'�'mom+5 BUILDING: TYPE CONST 2 OCC. GRP. Mailing Address3a A.P. Number ity Zip Llel. Legal Descriptio 9�a - Contrac or _ Project Description ss _ , J IJ /op Address or Zt' fi► [��ti9T�1 ZIp7� Tel. State Lic. ity & Classif. -71 f qo Cl r FLic. # Arch., Engr., A4/ J� Designer a a°i I Lic. #6- ,32 6qz LICENSED CONTRACTOR'S DECLARATION I hereby affirrD thal I aM licensed under provisions of Chapter 9 (commencing with Section 7000) of Divi n of �siness "a Professions Code, and my license is I ull fort and effect. — yw s�y�v j. e SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lend � ame Lender's A ss This is a but permit when properly tilled out, signed and validated, and is subject to expiration if work the oder is suspended for 180 days. I certify that I have r d this application and state that the above information is correct. I agree to comply with all 4 and county ordinances and state laws relating to building construction, and hereby authdr' a representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT I lllh_�NhN I Sq. Ft. /77,7/& No. of No. Dw. Size Stories Units New W" Add ❑ Alter ❑ Repair ❑ Demolition ❑ 4 ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE Lim 1 Estimated Valuation /!h PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. At IM n MWW Infrastructure NCE D PT TOTAL REMARKS 4 ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE l Coachella Valley Unified School District .83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: _ AMOUNT LEVEL ONE AMOUNT: LEVELTWOAMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE: s RECEIPT: CHECK#: - INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: • iHideaway Date: December 7, 2011 Owner's Name: Lee Ames Phone No. Project Address: 53-672 Via Palacio, LaQuinta, CA Project Description: Single Family Dwelling APN: 777-220-016 Tract #: Lot #'s: Type of Development: Residential : XX Commercial Industrial Total Square Feet of Building Area: 4766 Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: December 7, 2011 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code- Gov. Code Project Agreement Existing 17620 .65995 Approval 1.Prior to 1/1/87 Note: ' t Number of Sq.Ft. 4766 Amount per Sq.Ft. $2.97 Amount Collected $14155.02 Building Permit Application Completed: Yes/No. By:- Jamie T. Brown, Asst. Supt., Business Services Not Subject to Fee Requirement Certificate issued by: Laurie Howard, Secretary Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to. protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. M V:c/mydocs/devlees certificate of'compliance Y 11/2010 WHEN RECORDED MAIL TO: Lee and Natalie Kern Ames 79-616 Mission Drive East La Quinta, CA 92253 MAIL TAX STATEMENT -TO: SAME AS ABOVE (This space for Recorder's use only) , DOCUMENT TRANSFER TAX $ XX Computed on,the consideration or value of property conveyed; OR Computed on the consideration or value less liens or encumbrances remaining at the time of sale. Signature of DeclarantorAgent determining tax — Firm Name GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company ("Grantor"), hereby GRANT(S) to Lee Ames and Natalie Kern Ames, husband and wife ("Grantee"), the real property located in the City of La Quinta, County of Riverside, State of California, described as: See Legal Description attached hereto and incorporated herein as Exhibit "A". SUBJECT TO all matters of record including, without limitation, the covenants and agreements described in Exhibit "A" attached hereto. 'Dated: February 27, 2003 ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company By: Nationwide Realty Investors, Ltd. an Ohio limited liability company. its managing ember By: Josep I, Arenson Authorized Representative STATE OF California ) ss. COUNTY OF Riverside On Fzbrugr,,i a l , 2003, before me, the undersigned, a notary public in and for said State, personally appeared Joseph, L. Arenson(or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is subscribed to the within instrument and acknowledged to me that he executed the same in his authorized capacity(ies), and that by hi -s signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS MY HAND AND OFFICIAL SEAL. KATHRYN L. HUNTER • Signature p� [SEAL] "`' commission # 1382692 Z Notary Public California ; Riverside county w my comm. Expires Nov 1. 2006 r . F I-LA/627969.1 2 j EXHIIBT "A" Legal Description . . . Parcel No. 1: Lot 230 (the "Lot") of Amended Tract No. 29894-2 as shown'on Subdivision Map (the "Map") recorded on December 12, 2002; in Book 327, Pages 56 to 88, inclusive, of Maps, in the Office of the Riverside County Recorder. EXCEPTING AND RESERVING THEREFROM TO GRANTOR, and its successors,. assigns, invitees, licensees and employees, together with the right to grant and transfer all or a portion of the same, all easements and rights for access, ingress, egress, encroachment, maintenance, drainage, support, and for other purposes over the Association Maintenance Areas and other portion of the Lot, reserved to Grantor in the following instruments: 1. The Amended and Restated Declaration of Covenants, Conditions and Restrictions and Reservation of Easements for The Hideaway -Owners Association (as amended or supplemented, the "Declaration"), recorded on December 13, 2002, as Instrument No. 2002- 745939, of Official Records of Riverside County, California (the "Official Records"); FURTHER RESERVING THEREFROM, the right to enter the Lot for a term of twelve (12) months following the recordation of this Grant Deed, to complete and repair any improvements or landscaping located thereon as determined necessary by Grantor, in its sole discretion, in order to comply with requirements for the recordation of the Final°Tract Map, the grading of said Tract and/or in compliance with the requirements of applicable governmental agencies. Such entry by Grantor.shall be preceded by reasonable notice to Grantee before such entry.If this reservation of right of entry is not complied with by Grantee, Grantor may enforce this right of entry in a court of law. Grantee shall be responsible for all damages arising out of said breach including attorneys' fees and court costs. This reservation of right of entry shall automatically expire twelve (12) months from the recordation of this Grant Deed. Parcel No. 2: Nonexclusive easements for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as described in the Declaration. SUBJECT TO: 1. Non delinquent general, special and supplemental real property taxes and assessments. 2. All other covenants, conditions, restrictions, reservations, easements, rights and rights-of-way of record including, without imitation, the Declaration and the Map for Tract No.,' ' 29894-2. Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and approves.all of the foregoing in this Grant Deed, -(b) grants to Grantor and -The Hideaway Owners Association such powers and rights as are set forth in the Declaration., and (c) accepts, covenants and agrees to be bound by and assume performance of all of the applicable provisions and requirements set forth in the Declaration, including Section 13.15 establishing the procedure for resolving disputes with Grantor, and the notice, which provisions and requirements are acknowledged to. be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be performed by Grantee under the Declaration. The restrictions on use and occupancy of the Lot are set forth in the Declaration to which this Grant Deed is specifically and expressly made subject. GRANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING, granting unto Grantor and The Hideaway Owners Associa ion such powers and rights which are set forth in the Declaration defi ove, on 2003. Lee Ames Natalie Kern Ames STATEOF a� ) ss. .COUNTY OF IC1 Y2.f5 i d P� On 2003, before me, the undersigned, a notary public in and for said State, personally appeared Lee Ames and Natalie Kern Ames, personally known to me (or proved to me on the basis of satisfactory evidence) to be the persons -whose names are subscribed to the within instrument and acknowledged to me that they executed the same in their authorized capacities, and that by their signatures on the instrument the persons, or the entity upon behalf of which the persons acted, executed the instrument. WITNESS MY HAND.OFFICIAL SEAL o(• SLV [SEAL] Signature KATHRYN L. HUNTER Commission # 1382692 Z Z -� Notary Puolic - California > Z Riverside County My Comm. Expires Nov 1, 2006 a, RIVERSIDE CouN.TX FIREDEPARTMENT = , IN COOPERATION WITH THE CALIFORNIA DEPARTMENT, OF FORESSFRY AND FIRE PROTECTION '77-933 Las Montanas Rd., Ste. #201, Palm• Desert,'.CA-,92211-4131 • Phone .(760) 863-8886 • Fax (760) 863-7072 ' www..rvcfire.org PROUDLY SERVING THE UNINCORPORATED AREAS September l,'2011 OF RIVERSIDE COUNTY p AND THE CRIES OF: JD Mechanical, Inc. BANNING 43-160 Madison. Street BEAUMONT Indio, CA 92201 CALIMESA Re: Residential Fire Sprinkler Plan Review CANYON LAKE PC #11-937/53-672 Via Palacio COACHELLA DESERT HOT SPRINGS The Riverside County Fire Department Planning & Engineering personnel have reviewed your sprinkler plans for the above referenced project. Please be advised that your plans require the EASTVALE following corrections. INDIAN WELLS Please provide the following information in your next submittal: INDIO LAKE ELSINORE 1) Provide.a recent (within 6 months) water flow verification letter from the water purveyor 2) Provide manufacturers cut sheet for the water meter LA QUINTA 3) Provide a meter detail MENIFEE 4) The riser shutoff valve is prohibited (2010 CRC sec:.R313.3.3.2, see attached) 5) Sprinkler coverage is not required in bathroom(s) and closet(s) less than 55 sq.ft. MORENO VALLEY PALM DESERT NO inspections will be performed until Riverside County Fire Department Planning & PERRIs.. Engineering staff has approved the corrected plans. RANCHO MIRAGE RuBIDOux CSD All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. SAN JACINTO TEMECULA WILDOMAR Sincerely, BOARD OF SUPERVISORS: ✓ Jason Walsh BOB BUSTER DISTRICT Fire Safety Specialist JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOfr DISTRICT 4 MARION ASHLEY DISTRICT 5 BUILDING ENERGY ANALYSIS REPORT PROJECT: Ames Residence 53= Via Palacio, Lot 230, The Hideaway La Quinta, CA 92253 -Project Designer:- Helton, Derord & Associates 126!'N'. Big Spring Street Anaheim', Ca.92807 (909) 957-4550 \ Report Prepared by:. Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 A . 8 F FL Ce,(760),200ffL4, [11 7,q FBU91L�DING F LA QUINTA & SAFETY DEPT. OCT 2 � l0it PROVED By FOR CONSTRUCTION DA Z Zo `` 6Y Job Number: 11-37 Date: 8/17/2011 The EnergyPro computer p'rograrri hasbeen used to perform the calculations summarized in this compliance report. This program has approval and is authorised by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. N•� This program developed by EnergySoft, LLC — www.energysoft.com. } - � EnergyPro5.1 by,EnergySoft User Number. 6712. RunCode:2011-08-17711:37:35 ID: r: 0 C PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Ames Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1811712011 Date Project Address 53-716 Via Palacio, Lot 230, The Hideawa California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,716 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -= If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of.5 Status Roof Wood Framed Attic R-38 4,716 Radiant Barrier New Wall Wood Framed R-21 4,137 New Slab Unheated Slab -on -Grade None 4,716 Perim = 459' New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Left (N) 100.0 0.390 0.39 none none Bug Screen New Left (N) 70.5 0.390 0.39 none none Bug Screen New Rear (E) 57.8 0.390 0.39 none none Bug Screen New Rear (E) 104.0 0.390 0.39 8.0 none Bug Screen New Right (S) 86.0 0.390 0.39 none none Bug Screen New Front 96.0 0.390 0.39 8.0 none Bug Screen New Left (N) 96.0 0.390 0.39 6.0 none Bug Screen New Rear (E) 220.0 0.390 0.39 12.0 none Bug Screen New Rear (E) 96.0 0.390 0.39 none none Bug Screen New Right (S) 152.0 0.390 0.39 6.0 none Bug Screen New Front (tM 25.5 0.390 0.39 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 2 Central Furnace 80% AFUE. Split Air Conditioner 15.2 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION Location Heating,Cooling Duct Duct Location R -Value Status HVAC 1 Ducted Ducted . Attic, Ceiling Ins, vented 8.0 New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Large Gas 100 0.80 All Pipes Ins New EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-08-17711:37:35 ID: 'Page 3 of 27 i 0 0 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Ames Residence Building Type m Single Family ❑ Addition Alone ❑'Multi Family ❑ Existing+ Addition/Alteration Date 8/17/2011 Project Address 53-716 Via Palacio, Lot 230, The Hideawal California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,716 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes 0 No 'HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 -of this form for details. INSULATION Area Special Construction Type Cavity.(ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (lAq 90.0 0.390 0.39 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat _ Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Statusl EnergyPro 5.1 by EnergySoft User Number. 6712. Run Code: 2011-08-17T11:37:35 /D: Page 4Jof27 • • PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Ames Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/17/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford -White M-1-10OT6BN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met. HIGH MASS Design - Verify Thermal Mass: 430.0 ft2 Covered Slab Floor, 3.500" thick at Zone 1 Master Suite HIGH MASS Design - Verify Thermal Mass: 867.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 1 Master Suite The HVAC System HVAC 2 & 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air /low requirements and fan watt draw requirements in Residential Appendix RA -3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 2,138.OW 2 Exposed Slab Floor, 3.500" thick at Zone 3 & 4 Great/Mom/Kit/Din/Foyer HIGH MASS Design - Verify Thermal Mass: 441.0 ft2 Covered Slab Floor, 3.500" thick at Zone 3 & 4 Great/Mom/Kit/Din/Foyer HIGH MASS Design - Verify Thermal Mass: 237.0 ft2 Covered Slab Floor, 3.500" thick at Bedroon 2 HIGH MASS Design - Verify Thermal Mass: 128.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroon 2 The HVAC System HVAC 4 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met. HIGH MASS Design - Verify Thermal Mass: 403.0 ft2 Covered Slab Floor, 3.500" thick at Guest Bedroom HIGH MASS Design - Verify Thermal Mass: 72.0 ft2 Exposed Slab Floor, 3.500" thick at Guest Bedroom The Roof R-38 Roof(R.38.2x 14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24ABC648/58CVX090 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation ' of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ABC660/58CVX110 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 & 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ABC624158CVX070 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-08-17711:37:35 ID: Page 5 of 27 PERFORMANCE CERTIFICATE:. Residential (Part 3 of 5) CF -1 R Project Name Building Type mSingle Family ❑ Addition Alone Date Ames Residence ❑ Multi Family Ij Existing+ Addition/Alteration $/17/2011 .ANNUAL. ENERGY USE SUMMARY.. _ Standard Proposed Margin TDV ' kBtu/ft2- r Space Heating 4.54 3.45 1.09 - Space Cooling 58.76 48.74 10.02 Fans 12.05 14.86 -2.84 Domestic Hot Water 7.73' 5.20 2.53 ' Pumps 0.00 0.00 0.00 Totals 83.08 72.28 10.80 Percent Better Than, Standard:: BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (SM 237 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: too (S K9 1,303 212 Fuel Available at Site: Natural Gas (NW) 1,285 267 Raised Floor Area: 0 (NE) 1,366 478 Slab on Grade Area: 4,716 (SE) 1,377 238 Average Ceiling Height: '11.4 Roof 4,716 0 Fenestration Average U -Factor: 0.39 TOTAL: 1,194 Average SHGC: 0.39 Fenestration/CFA Ratio: 25.3% REMARKS f • STATEMENT OF COMPLIANCE. This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author. Company Scott Design and Title 24, Inc, 8/17x2011 Address 77-065 Michigan Drive Name ..Tim Scott City/State/Zip.Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with' the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business &'Professions Code) Company Helton, DeFord & Associates Address 1261 N. Big Spring Street Name Dave Helton City/State/Zip Anaheim, Ca 92807 Phone (909) 957-4550 Signed License # Date EnerqyPrp 5.1 by EnemySoft. user Number: 6712 Runcode: 2011-08-17T11:37:35 _ID: Page 6 of 27 CERTIFICATE OF COMPLIANCE: Residential �, (Part 4 of 5) CF -1 R Project NameBuilding Ames Residence ; Type m Single Family ❑Addition Alone t ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8117/2011 OPAQUE SURFACE DETAILS. F I ,- Surface Type Area, U Insulation Factor Cavit Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 iLocation/Comments Roof 1,297 0.026 R-38 0 _ 20 New- 4.2.1-A9 Zone 1 Master Suite Wall 520 0.069 R-21 - 0 90 New 4.3.1-A6 Zone 1 Master Suite- Wall 233 0.069 R-21 90 90 New 4.3.1-A6 Zone 1 Master Suite , Wall 253 0.069 R-21 .. 180 90 New 4.3.1-A6 Zone 1 Master Suite Wall 1871 0.069 R-21 270 90 New 4.3.1-A6 Zone 1 Master Suite Slab 4301 0.730 None • 0 .180 New 4.4.7-A1 Zone 1 Master Suite Slab 867 • • 0.730 None 0 180 New 4.4.7-A1 Zone 1 Master Suite Roof 2,579 0.026 R-38. 0 20 New 4.2.1-A9 Zone 3 & 4 Great/Momin Wall 387 0.069 R-21 0 90 New 4.3.1-A6 Zone 3 & 4 Great/Morning Wall 386 0.069 R-21 90 90 New 4.3.1-A6 Zone 3 & 4 Great/Morning, Wall 571 0.069 R-21 ., 180 90 New 4.3.1-A6 Zone 3 & 4 Great/Moming Wall 384 0.069 R-21.. -270 90 New 4.3.1-A6 Zone 3 & 4 Great/Momin Slab 2,138 0.730 None 0 180 New 4.4.7-A1 Zone 3 & 4 Great/Momin Slab 441 . 0.730 None 0 180 New 4.4.7-A1 Zone 3 & 4 GreatlMomin Roof 365 0.026 R-38 0 20 New 4.2.1-A9 Zone 3 & 4 Great/Momin Wall 65 0.0691R_21 90 90 New 14.3.1-A6 JZone 3 & 4 Great/Momin FENESTRATION SURFACE DETAILS , `ID T e Area .U -Factor SHGC Azm Status GlazingType Location/Comments 1 Window 20.0 0.390 NFRC 0.39 NFRC • - " 0 New Clad Wood Doors Zone 1 Master Suite 2 Window 6.0 0.390 NFRC 0.39 NFRC 0 New Double non-metal tinted Zone 1 Master Suite 3 Window • 33.0 0.390 NFRC 0.39 NFRC 0 New . Double non-metal tinted Zone 1 Master Suite 4 Window 6.0 0.390 NFRC 0.39 NFRC 0 New Double non-metal tinted Zone 1 Master Suite 5 Window ' 41.3 0.390 NFRC 0.39 NFRC 90 New Double non-metal tinted Zone 1 Master Suite 61 Window 5.104.0 0.390 NFRC 0.39 NFRC 90 New Clad Wood Doors Zone 1 Master Suite 7 ' Window 6.0 0.390 NFRC 0.39 NFRC 180 New Double non-metal tinted Zone 1 Master Suite 8 Window 6.0 0.390 NFRC 0.39 NFRC 180 New Double non-metal tinted Zone 1 Master Suite _ 9 Window 96.0 0.390 NFRC .0.39 NFRC 270 New Clad Wood Doors Zone 1 Master Suite 10 Window 96.0 0.390 NFRC 0.39 NFRC 0 New Clad Wood Doors Zone 3 & 4 Great/Morning/Kit/ 11 Window 6.0 0.390 NFRC 0.39 NFRC 0 New Double non-metal tinted Zone 3 & 4 Great/Morning/Kit/ 12 Window j 80.0 0.390 NFRC 0.39 NFRC 0 New Clad Wood Doors Zone 3 & 4 Great/Morning/Kit/ 13 Window 6.0 0.390 NFRC 0.39 NFRC 0 New Double non-metal tinted Zone 3 & 4 Great/Moming/Kitl • 14 Window 220.0 0.390 NFRC -0.39 NFRC 90 New Clad Wood Doors Zone 3 & 4 Great/Morning/Kit/ 15 Window 96.0 0.390 NFRC 0.39 NFRC 90 New Clad Wood Doors Zone 3 & 4 Great/Moming/Kit/ 16 Window 72.0 0.390 NFRC 0.39 NFRC 1 180 New Clad Wood Doors Zone 3 & 4 Great/Momingfi%I (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B'= Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC - Window H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist I Len Hat 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 • Bug Screen 0.76 - 5 Bug Screen 0.76 6 Bug Screen . 0.76 8.0 13.0 8.0 0.1 8.0 8.0 7 Bug Screen,, 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 8.0 12.0 8.0 0.1 8.0 8.0 i 10 Bug Screen 0.76 8.0 12.0 6.0 0.1 6.0 6.0 11 Bug Screen 0.76 12 Bug Screen , 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 10.0 _ 22.0 12.0 0.1 .12.0 12.0 15 Bug Screen 0.76 16 JBug Screen 0.76 8.0 .. 9.0 6.0 0.1 6.0 6.0 EnergyFro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-08-17TH:37:35 ID: Pae 7 of 27 T • • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Ames Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/17/2011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 117 0.069 R-21 180 90 New 4.3.1-A6 Zone 3 & 4 Great/Moming Wall 278 0.069 R-21 270 90 New 4.3.1-A6 Zone 3 & 4 Great/Momin Slab 237 0.730 None 0 180 New 4.4.7-A1 Zone 3 & 4 Great/Momin Slab 128 0.730 None 0 180 New 4.4.7 -AV Zone 3 & 4 Great/Momin Roof 475 0.026 R-38 0 20 New 4.2.1-A9 Guest Bedroom Wall 112 0.069 R-21 0 90 New 4.3.1-A6 Guest Bedroom Wall 205 0.069 R-21 90 90 New 4.3.1-A6 Guest Bedroom Wall 198 0.069 R-21 180 90 New 4.3.1-A6 Guest Bedroom Wall 243 0.069 R-21 270 90 New 4.3.1-A6 Guest Bedroom Slab 403 0.730 None 0 180 New 4.4.7-A1 Guest Bedroom Slab 72 0.730 None 0 180 New 4.4.7-A1 Guest Bedroom FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 17 Window 8.0 0.390 1 NFRC 0.39 1 NFRC 180 New Double non-metal tinted Zone 3 & 4 Great/Moming/Kit/ 18 Window 80.0 0.390 NFRC 0.39 NFRC 180 New Clad Wood Doors Zone 3 & 4 Great/Moming/Kit/ 19 Window 6.0 0.390 NFRC 0.39 NFRC 180 New Double non-metal tinted Zone 3 & 4 Great/Moming/Kit/ 20 Window 13.5 0.390 NFRC 0.39 NFRC 270 New Double non-metal tinted Zone 3 & 4 Great/Moming/Kit/ 21 Window 90.0 0.390 NFRC 0.39 NFRC 270 New Clad Wood Doors Zone 3 & 4 Great/Moming/Kitl 22 Window 16.5 0.390 NFRC 0.39 NFRC 90 New Double non-metal tinted Zone 3 & 4 Great/Moming/Kit/ 23 Window 33.0 0.390 NFRC 0.39 NFRC 180 New Double non-metal tinted Zone 3 & 4 Great/Moming/Kit/ 24 Window 13.5 0.390 NFRC 0.39 NFRC 0 New Double non-metal tinted Guest Bedroom 25 Window 13.5 0.390 NFRC 0.39 NFRC 180 New Double non-metal tinted Guest Bedroom 26 Window 13.5 0.390 NFRC 0.39 NFRC 180 New Double non-metal tinted Guest Bedroom 27 Window 6.0 0.390 NFRC 0.39 NFRC 270 New Double non-metal tinted Guest Bedroom 28 Window 6.0 0.390 NFRC 0.39 NFRC 270 New Double non-metal tinted Guest Bedroom (1) 1.1-FactorType: 116-A= Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 8.0 10.0 6.0 0.1 6.0 6.0 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Buq Screen 0.76 28 Bug Screen 0.76 EnergyPro 5.1 by EnergrySoft User Number: 6712 Run Code: 2011-08-17711:37:35 ID: Page 8 of 27 C CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Ames Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1811712011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC 1 Zone 1 Master Suite 1,297 13,359 HVAC 2 & 3 Zone 3 & 4 Great/Mom/Kit/Din/F2579 31,980 Bedroon 2 365 3,650 HVAC 4 Guest Bedroom 475 4,750 Totals 4,7161 011 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC 2 & 3 2 Central Furnace 80% AFUE Split Air Conditioner 15.2 SEER Setback New HVAC 4 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 M New WATER HEATING SYSTEMS S stem Name aty. Type Distribution. Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White M -1-100T6 1 Large Gas All Pipes Ins 85,000 100 0.80 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o, ¢ — System Name Pipe Len th Pipe Diameter Insul. Thick. Qt . HP Plenum Outside Buried ❑ EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2011-08-17T11:37:35 ID: Page 9 of 27 MANDATORY MEASURES SUMMARY: Residential ., Pae 1 of 3 MF -1 R Y _ � NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (") below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelo e'Measures: ' 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leaka e. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111(a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF_6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent LI -factor. } 150(b):, Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retardinq'wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the' CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or'16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 erm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliancesand Gas Log Measures: . 150 (e)1A: Masonry or factor -built fireplaces have a closable metal or glass doorcovering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible; operable, and ti ht-fittin 6 clamper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor,air for cooling a firebox jacket, when that indoor air is vented to the .outside of the building; are prohibited. MANDATORY MEASURES SUMMARY: Residential ., Pae 1 of 3 MF -1 R Project Name _ mes Residence Date 8/17/2011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (") below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelo e'Measures: ' 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leaka e. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111(a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF_6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent LI -factor. } 150(b):, Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retardinq'wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the' CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or'16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 erm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliancesand Gas Log Measures: . 150 (e)1A: Masonry or factor -built fireplaces have a closable metal or glass doorcovering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible; operable, and ti ht-fittin 6 clamper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor,air for cooling a firebox jacket, when that indoor air is vented to the .outside of the building; are prohibited. Space Conditioning, Water.Heating and Plumbing System Measures:., §11.0-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. . ' §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces,. household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. ' 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating s stems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12'external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot 'water tank shall be insulated to Table 150-B and Equation 150-A. ' §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(4)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. r §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in .conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-08-17T11.37:35 ID: Page 10 of 27 t I 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date mes Residence 8/17/2011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-08-17711:37:35 ID: Page 11 of 27 MANDATORY MEASURES SUMMARY: Residential (Pace 3 of 3) MF -1 R Project Name Date Imes Residence 1811712011 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by'a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150(k)l 1. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high.efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that thev are controlled by an occupant sensor(s) certified to comply with the applicable requirements of §119. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-08-17711:37:35 /D: Page 12 of 27 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name mes Residence Date 8/17/2011 System Name HVAC 1 Floor Area 1,297 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,004 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 71,000 18,640 2,458 422 18,238 Total Output Btuh 71,000 0 Output B4uh/s ft 54.7 1,076 896 Cooling System 0 0 Output per System 46,500 0 0 0 0 Total Output Btuh 46,500 0 1,076 1 20,793 2,458 0 Total Output Tons 3.9 896 Total Output Btuh/s ft - 35.9 Total Output s ft/Ton 334.7 1 20,031 Air System CFM per System 1,600 HVAC. EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 24ABC648/58CVX090 31,854 5,746 71,000 Airflow cfm/s ft 1.23 71,000 Jan 1 AM Airflow cfm/Ton 412.9 Outside Air % 0.0 % . Total Adjusted System Output 31,854 5,746 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 71 OF 71 OF 1130F 113 OF x�r Heating Coil Supply FaILIn 113 OF 1,600 cfm ROM f ill 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0,cfm 71/59°F 71 /59°F 52/51 OF 52/51 OF - Cooling Coil Supply Fan 53 / 51 OF 1,600 cfm................................................,j ., 51.4% ':ROOM 70!59°F I d EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-08-17711:37:35 ID: Page 13 of 27 .4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date mes Residence 8/17/2011 System Name Floor Area HVAC 2 & 3 2,944 ENGINEERING CHECKS SYSTEM LOAD Number of Systems . 2 COIL CFM Total Room Loads 2,642 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING Sensible 44,031 0 2,542 0 0 5,956 2,542 55,071 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output perSystem 89,000 5,363 928 41,726 Total Output Btuh 178,000 - Output Btuh/s ft 60.5 2,051 Cooling System 0 Output perSystem 57,500 0 0 0 Total Output Btuh 115,000 5,363 -5,956 Total Output Tons 9.6 2,051 Total Output Btuh/s ft 39.1 Total Output s ft/Ton 307.2 F 39,872 Air System CFM perSystem 2,000 HVAC EOUIPMENT SELECTION Airflow cfm 4,000 Carrier 24ABC660/58CVX110 77,710 15,473 178,000 Airflow cfm/s ft 1.36 Airflow cfm/Ton 417.4 178,000 Jan 1 AM Outside Air % 0.0% Total Adjusted System Output 77,710 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 15,473 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of"Heatin Peak 26 OF 72 OF 113 OF 115 °F V-' Outside Air 0 cfm Heating Coil Supply Fan 114 OF 4,000 cfm -ROOMr+ 72 OF 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 71/59°F 52/51°F• 54/52°F Outside Air � 0 cfm Cooling Coil Supply Fan 54 / 52 OF 4,000 cfm 51.9 ...._........-........-...... ........ ............ Bio f ROOM 71!59°F 70/59°F EnergyPro 5.1 by EnergySoR User Number.' 6712 Run Code: 2011-08-17711:37:35 /D: Page 14 of 27 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name mes Residence Date 8/17/2011 System Name HVAC 4 Floor Area 475 ENGINEERING CHECKS_ SYSTEM. LOAD Number of Systems 1 COIL CFM Total Room Loads 394 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 51,000 7,300 1,407 125 7,866 Total Output Btuh 51,000 0 ,Output Btuh/s ft 107.4 421 387 Cooling System 0 0 Output perS stem 24,000 0 0 0 0 Total Output Btuh 24,000 0 421 1 8,143 1,407 0 Total Output Tons 2.0 387 Total Output Btuh/s ft . 50.5 Total Output s f rrbn 237.5 F 8,639 Air System CFM perSystem 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Carrier 24ABC624/58CVX070 15,663 3,783 51,000 Airflow cfm/s ft 1.68 Airflow cfm/Ton 400.0 Total Adjusted System Output 15,663 3,783 51,000 (Aiijusted for Peak Design conditions) TIME OF SYSTEMpEAK Aug 3 PM Jan 1 AM Outside Air % 0.0 % Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions. HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 131 °F 131 OF ,x Heating Coil Supply Fan 800 cfm 131 ° F ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 0 cfm 70 / 59 OF 70/59°F 52/51 OF 52/51 °F% Cooling Coil Supply Fan 53 / 51 OF 800 cfm _........... .-- 52.1 % ` "RQVIYI 70 ! 59 OF EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2011-08-17T11:37:35 /D: Page 15 of 27 ROOM LOAD SUMMARY Project Name Ames Residence Date 8/17/2011 System Name HVAC 1 Floor Area 1,297 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone 1 Master Suite Zone 1 Master Suite 1 1,004 18,640 2,458 1,004 18,640 2,458 422 18,238 ' Total includes ventilation load for zonal s stems. PAGE TOTAL TOTAL' 1,004 1,004 18,640 18,640 2,458 2,458 422 18,238 422 18,238 Ene Pro 5.1 6 Ene Soft .. User Number. 6712 RunCode: 2011-08-17711:37:35 ID: Pae 16 of 27 ROOM LOAD SUMMARY Project Name Ames Residence . Date 8/17/2011 System Name HVAC 2 & 3. Floor Area 2,944 ROOM LOAD.SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name .. _ Mult. CFM Sensible Latentr382 Sensible, Latent CFM Sensible Zone 3 & 4 Great/Moming Zone 3 & 4 Great/Mom/Ki 1 2,260 37,667 4,096 37,667 4,096 785 35,277 Bedroon 2 1 382 6,364 1,266 6,364 1,266 143 6,449 Total includes ventilation load for zonal systems... , PAGE TOTAL TOTAL 1 2,642 2,6421 44,031 44,0311 5,363 5,3631 928 41,726 928 41,7 EnergyPro 5.1. by EnemySoft User Number: 6712 Run Code: 2011-08-17711:37:35 /D: Pae 17 of 97 . ROOM LOAD SUMMARY Project Name Date Ames Residence 8/17/2011 System Name Floor Area HVAC 4 475 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name ... Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sen"sible Guest Bedroom Guest Bedroom 1 394 7,300 1,407 394 7,300 1,407 125 7,866 0 PAGE TOTAL TOTAL` 394 7,300 1,407 1257,866 394 7,300 1,407 125 7,866 Total includes ventilation load for zonal systems. _. EnergyPro 5.1 by EnemySoft User Number: 6712 Run Code: 2011-08-17TH:37:35 ID: Pae 18 of 27 • ROOM HEATING PEAK LOADS. Project Name Ames Residence Date 8/17/2011 ROOM INFORMATION DESIGN CONDITIONS, Room Name Zone 1 Master Suite Floor Area 1,297.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X ,X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X- X X X X X X X X X X X° AT *F = = = = = = = = = = = = = = = = = = _ = = = = = = = = = _ 46 Btu/hr R-38 Rootff .38.2x14.16) 1,297.0 0.0260 46 1,551 R-21 Wall (W.19.2x6.16) 1,192.7 0.0690 46 3,786 Clad Wood Doors 220.0 0.3900 46 3,947 Double non-metal tinted 98.3 0.3900 46 1,764 Slab -On -Grade penm = 114.0 0.7300 46 3,828 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface 1.064 X 1,297 X Area another room 10.30 X 0.309 Height ACH Page Total /60] X AT 14,875 = 3,363 TOTAL" HOURLY HEAT LOSS FOR ROOM _ 18,238 EnergyPro 5.1 by EnergySoft . User Number: 6712 RunCode: 2011-08-17711:37:35 /D: Page 19 of 27 0 • ROOM HEATING PEAK LOADS Project Name Ames_ Residence Date 8/17/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 3 & 4 Great/Mom/Kit/Din/Foyer Floor Area 2,579.0 ft2 Indoor Dr ,Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction L064 Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F Btu/hr = 3,084 = 5,483 = 13,168 = 709 = 6,145 = = = = = = = = = = = = = = = - = = = = = _ = = = = 28,589 46 = 6,687 R-38 Roof(R.38.2x14.16) 2,579.0 0.0260 46 R-21 Wall (W.19.2x6.16) 1,727.5 0.0690 46 Clad Wood Doors 734.0 0.3900 46 Double non-metal tinted 39.5 0.3900 46 Slab -On -Grade perim = 183.0 0.7300. 46 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface X 2,579 X Area another room 12.40 X 0.256 Height ACH Page Total /60] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 35,277 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode:.2011-08-17711:37:35 ID: Page 20 of 27 ROOM HEATING PEAK LOADS Project Name Ames Residence --78/17/2011 Date ROOM INFORMATION , DESIGN CONDITIONS Room Name Bedroon 2 Floor Area 365.0 ft2 Indoor Dry Bulb Temperature 72 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area, _ X X X X X X X X `X X X X. X X X X X X X X X X X X X X X X X X X to Ceiling 1.11 -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X OT OF Btu/hr = 437 = 1,458 = 888 = 2,720 = = = = = = = = = - _ - = = - = = = = - = _ = = = - = 5,503 46 = 946 R-38 Roof(R.38.2x14.16) 365.0 0.0260 46 R-21 Wall (W..19.2x6.16) 459.5 0.0690 46 Double non-metal tinted 49.5 0.3900 46 Slab -On -Grade perim = 81.0 0.7300 46 - Items shown with an asterisk (') denote conduction Infiltration: 1.00 X Schedule Air Sensible Fraction through an interior surface 1.064 X 365 X . Area another room 10.00 X 0.318 Height ACH Page Total / 60 X AT TOTAL- HOURLY HEAT LOSS FOR ROOM 6,449 EnergyPro5.1.by EnergySoft User Number: 6712 Run Code: 2011-08-17T11:37:35 ID: Page 21 of 27 ROOM HEATING=PEAK LOADS Project Name Ames Residence Date 8/17/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Bedroom Floor Area 475.0 ft2 Indoor Dry Bulb Temperature 72 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 475.0 X 757.5 X 52.5 X pen Im = 81.0 X X X X U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F = = = = = = = = = = = = = = = = - = = = = = _ = = _ = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 0.0260 46 568 R-21 Wall (W.19.2x6.16) 0.0690 46 2,404 Double non-metal tinted 0.3900 46 942 Slab -On -Grade 0.7300 46 2,720 X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to )( 475 X Area Ceiling Items shown with' an asterisk (') denote conduction Infiltration: 1.00 'X 1.064 Schedule Air Sensible Fraction another room 10.00 X 0.318 Height ACH Page Total / 60 ,X AT 6,634 = 1,232 TOTAL HOURLY HEAT LOSS FOR ROOM 7,866 EnergyPro 5.1 by Energ Soft User Number: 6712. Run Code: 2011-08-17711:37:35 ID: Page 22 of 27 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ames Residence 8/17/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone -1 Master Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,297.0ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 of Outdoor Dally Range: 34 OF ODaaue Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W.19.2x6.16) Area 1,297.01 520.0 X X X X X X X X X U=Factor X X X X X X X X X CLTD' = = = = = = = = = 0.0260 56.0 0.0690 23.0 232.7 253.0 187.0 0.0690 33.0 0.0690 26.0 0.0690 33.0 22.3 33.0 22.3 0.0 22.3 6.0 22.3 0.0 81.9 22.3 + Page Total L Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration 1G 109 108 107 110 1J 101 100 is Orientation Area X X X X X X X X X GLF Area X X X X X X X X X GLF = = = = = = = = = 0.0 22.3 + + + + 20.0 22.3 0.6 22.3 6.0 22.3 0.0 22.3 33.0 22.3 0.0 22.3 6.0 22.3 0.0 81.9 22.3 + 41.3 45.4 22.3 + 22.1 45.4 0.0 0.0 75.6 22.3 + + + 6.0 22.4 22.3 6.0 22.4 22.3 20.4 45.4 Page Total Btu/hr 1,888 825 530 454 426 4,123 Btu/hr 445 134 735 134 1,876 2,828 134 134 2,6101 9,031 Internal Gain Btu/hr Occupants 4.0. Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 j( 0.94 X 70.97 X 42 = 2,967 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR_ROOM 18,640 Latent Gain Occupants, 4.0 Occupants X .2001 Btuh/occ. Infiltration: 4,771 X 0.94 X 70.97 X 0.00523 Air Sensible CFM ELA AW • TOTAL HOURLY LATENT HEAT GAIN FOR Btu/hr Boo 1 1,6581 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Ames Residence ROOM INFORMATION _ DESIGN CONDITIONS Room Name Zone 3 & 4 Great/Mom/KitlDin/Foyer Outdoor Dry Bulb Temperature Floor Area 2,579.0 ft' Outdoor Wet Bulb Temperature Indoor Dry Out Temperature _ .70 OF Outdoor Dally Range: Opaaue Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) Orientation Date 8/17/2011 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 2,579.0 0.0260 56.0 387.0 0.0690 23.0 386.0 0.0690 33.0 571.0 0.0690 26.0 383.5 0.0690 33.0 + 96.0 45.4 72.0 + + 0.0 22.4 0.0 8.0 22.4 80.0 +. 0.0 22.41 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Orientation (N) .. (N) (N) (N) (E) (E) (S). (S) (S) Shaded Unshaded 112 OF 78 OF 34 OF Btu/hr 3,755 614 879 1,024 873 1 7,1461 Area GLF X 22.3 X 22.3 X 22.3 X 22.3 X 22.3 X 22.3 X 22.3 X 22.3 X 22.3 Area + 96.0 + 6.0 + 80.0 X X X X X X X X X GLF = = = = = = = = = 0.0 22.3 0.0 22.3 0.0 22.3 0.0 + 6.0 22.3 209.01 + 11.0 45.4 0.0 + 96.0 45.4 72.0 + + 0.0 22.4 0.0 8.0 22.4 80.0 +. 0.0 22.41 Page Total Btu/hr 2,138 134 1,782 134 5,155 4,361 1,604 179 1,782 17.267 Internal Gain Btu/hr Occupants 4.0 Occupants X 230' Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 141.12 X 42 = 5,899 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM _ 37,667 Latent Gain Occupants 4.0 Occupants X 200 Btuh/occ. Infiltration: 4.771 X 0.94 X 141.12 X 0.00523 = Air Sensible CFM ELA AW • TOTAL HOURLY LATENT HEAT GAIN - Btu/hr 800 1 3,2961 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ames'Residence 8/17/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 3 & 4 GreabMom/KibDin/Foyer Outdoor Dry Bulb Temperature 112 OF Floor Area 2,579.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dail Ran e: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X = X X = X X _ X X = X X = X X = X X = X X = X X = Page Total o Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 115 (S) 0.'0 X 22.3 + 6.0 X 22.4 = 134 114 NO 0.0 X 22.3 + 13.5 X 45.4 = 613 M (VIS 0.0 X 22.3 + 90.0 X 45.4 = 4,088 X + X X + X = X + X = X + X X + X = X + X = Page Total 4,836 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment . 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 . X 0.94 X 141.12 X 42 _ F775,899 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR. ROOM 37,667 Latent Gain Btu/hr Occupants 4.0. Occupants X 200 Btuh/occ. = 800 Infiltration: 4.771 X 0.94 X 141.12 X 0.00523 = 3,296 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM_ 4,096 EnemyPro, 5.1 b' EnemySoft • User Number: 6712 Run Code: 201.1-08-17TH:37:35 ID: Pa a 25 of 27 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ames Residence 8/17/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name. Bedroon 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 365.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor. Dry Bulb Temperature 70 OF Outdoor. Daily Range:. 34 OF Opaque Surfaces Orientation Area U=Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (N) 366.01 X 0.0260 X 56.0 = 531 R-21 Wall (W.19.2x6.16) (E) 64.5 X 0.0690 X 33.0 = 147 R-21 Wall (W.19.2x6.16) (S) 117.0 X 0.0690 X 26.0 = 210 R-21 Wall (W. M.M.16) NO 278.0 X 0.0690 X 33.0 = 633 X X = X X = X X = X X = X X = Page Total 1,521 Items shown with an asterisk (`) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 112 (E) 0.0 X 22.3 + 16.5 X 45.4 = 750 0.0 X 22.3 + 33.0 X 22.4 = 738 X + X = X + X = X + X = X + X = X + X = X + X = X + X I= Page Total 1,488 Internal Gain Btu/hr Occupants 4.9 Occupants X. " 230 Btuh/occ. _ 920 Eq ui ment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltrations 1.064 X 0.94 .X 19.97 X 42 = 835 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,364 Latent Gain Btu/hr. Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.94 X 19.97 X 0.00523 = 466 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM._ 1,266 Ene Pro 5.1 by Ene Soft. User Number: 6712. Run Code: 2011-08-17711:37:35 ID:. Page 26 of 27 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ames Residence 8/17/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 475.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (N) 475.0 X 0.0260 X 56.0 = 692 R-21 Wall (W.19.2z6.16) (N) 111.5 X 0.0690 X 23.0 = 177 R-21 Wall (W. 19.2x6.16) (E) 205.0 X 0.0690 X 33.0 = 467 R-21 Wall (W.19.2x6.16) (S) 198.0 X 0.0690 X 26.0 = 355 R-21 Wall (W. 19.2x6.16) (l" 243.0 X 0.0690 X 33.0 c 553 X X = X X = X X = X X = Page Total 2,244 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 102 (N) 0.0 X 22.3 + 13.5 X 22.3 = 301 103 (S) 0.0 X 22.3 + 13.5 X 22.4 "= 302 104 (S), _ 0.0 X 22.3 + 13.5 X 22.4 c 302 105 W 0.0 X 22.3 + 6.0 X 45.4 = 273 106. (tM .0.0 X 22.3 + 6.0 X 45.4 = 273 X + X = X + X - X + X - X +1 X = Page Total 1,450 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. _ 920 E ui ment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 25.99 X 42 = 1,086 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7,300 Latent Gain Btu/hr Occupants.. 4.0 Occupants X F 200 Btuh/occ. _ 800 Infiltration: 4,771 X 0.94 X 25.99 X 0.00523 = 607 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,407 Ene Pro5.1 6 Ene Soft . User Number: 6712. RunCode: 2011-08-17711:37:35 ID: Page 27 of 27 a. 'Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 10/19/2011 Electronically Signed at Ca10ERTS.com'by David'W Helton (Helton, Deford & Associates) 10/19/2011 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Ames Residence Building Type r ® Single Family ❑ Addition Alone ❑ Multi Family - ❑ Existing+ Addition/Alteration 11011912011 Date Project Address- 53-716 Via Palacio, Lot 230, The Hideawa California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,716 Addition 1 n/a # of Stories I 1 FIELD INSPECTION ENERGY CHECKLIST' : El Yes ❑ No. HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If -Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attica R-38 4,716 Radiant Barrier New Wall Wood Framed 37 New Slab Unheated Slab -on -G de O o . 01 1 Pe 'm = 459' ,---.—.--New--- BUILDING SA o li 114' ' ' � 01 trv� I f I I t; 0 L T FZ a tul t:y FENESTRATION;" F ' Exterior ►=-=`--""`-� �,;; Orientation. Area fiz' Factor SHGC Overhan Sidefins Shades Status . Left (N) f 00 0 .:; , x,0,390 0.39 none none Bug Screen New "' none Bu Screen Left (N) :: = 69.0 "0:390� 0 39; �€..:...... xip;�.:_.:g ,.mska...,..- . New 71 3 �0 390r" _ 0 39none ���none`F"?Bug Scr a New Rear (E)�" : y104 0::ry0. 90 0 398 0 none, .' Bug Scr ee nix, • New .i, d. j rK t,..r.. t .T. fi•• 0 39'none g< none Bu Screen,,,. E, New gas . Right.60 �� m X59 0 . ' 0 390 . , t Y <. 9 � � � ( 960 x0390 039 80 �SugScreenrq� `, Fronk _ $+x �� +0, . g#fi none i'1 ,. New; ..:>: cTP,.?F x.€ w - .s Y .V„�yh'� •' ax ke :.. i.r + .{-w.� .- - r ... ... .. .. Left (N) <:: , .,. , ? :: 96 0 , + •;•t 0.390 y 0 39 6 0 ' - none Bug Screen:' :: :. _, New Rear (E) ; , �,,.�s `220 0 , z'. '� 0:390 0.39 12.0' . none ' Bug Screen New 960'. E ` 0.390 0.39 none none Bug Screen New Right:(S) ` 152,0 ;` 0.390. 0.39 6.0 none Bug Screen New _ Front (W) 40 5 ti �- 0.390 0.39 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff. - Coblin6 Min. Eff Thermostat' Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 15.2 SEER Setback - 'New 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value - Status HVAC 1 Ducted „ Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 & 3 Ducted",Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 4 Ducted Ducted' Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Large Gas 100 0.80 All Pipes Ins New ' t EnergyPro5.1 by Ener Soft User Number: 6712 RunCode: 2011-08-17713:11:59 ID: Page 1 of 7 Reg: 211-N0054484A-000000000-0000 Registration Date/Time: 2011/10/19 17:98:50 HERS Provider: Ca10ERTS, Inc • b r r .r w .. " a �S i c W 5, Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 10/19/2011 t f •')+ Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 10/19/2011 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Ames Residence Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 10/19/2011 Project Address 53-716 Via Palacio, Lot 230, The Hideawal California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,716 ' Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST 0 Yes . ❑ No HERS Measures -- If Yes, "A CF -4R must be.provided per Part,2 of 5 of this form.' El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION = v U= Exterior Orientation>_. Area ft? _;Factor SHGC Overhang Sidefins Shades Status Front(Vl� 900y' ' x,0.390 0.39 none none Bug Screen New F�W C: " � �z '�.1y'T��°i"F• S Tj� �. �., - _ Y 'A�^{ $ }- �•'a.'(, "f R "M.•nww ...iE Vu,. .r P�.is �P•C. ��a.�*�i�4 A'x"AF".. � k� �y%T ro1 SSYlxL .�:+ai 8�.' i��Ak53P�'��..P.'":. � ...'�,r ^SF v �"5.: .6�..,,�^�.,. S ,Tr"."�� *R`�.¢.�...ay ,tr'+ •.t{`i''fi7.'4rf�' ,.C: � � ,n� ... ... _ � � s+ HVAC SYSTEMS_ Qty. Heating Min. Eff. Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location . Heating Cooling Duct Location R -Value Status WATER HEATING Ot ., . Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2011-08-17T13:11.•59 ID: Pa e 2 of 7 Reg: 211-N0059989A-000000000-0000 Registration Date/Time: 2011/10/19 17:98:50 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 10/19/2011 t Electronically Signed at,Ca10ERTS.com by David,W,Helton (Helton, Deford & Associates) 10/19/2011 PERFORMANCE CERTIFICATE: Residential (Part 2, of 5)_ CF -1R Project Name Building Type' ® Single Family ❑ Addition Alone Date Ames Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 11011912011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach: The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. , . The DHW System Bradford -White M-1-100T6BN is a non -NA ECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se arate thermostat. In addition the air flow require ments and fan watt draw requirements in Residential Appendix RA -6 must be met. HIGH MASS Design - Verify Thermal Mass: 430.0 ft' Covered Slab Floor, 3.500" thick at Zone 1 Master Suite HIGH MASS Design - Verify Thermal Mass: 867.0 ft' Exposed Slab Floor, 3.500" thick at Zone 1 Master Suite The HVAC System HVAC 2 & 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -3.3 must be met. , HIGH MASS Design - Verify Thermal Mass: 2,138.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 3 & 4 Great/Morn/Kit/Din/Foyer HIGH MASS Design - Verify Thermal Mass: 441.0 ft' Covered Slab Floor, 3.500" thick at Zone 3 & 4 Great/Morn/Kit/Din/Foyer HIGH MASS Design - Verify Thermal Mass: 237.0 ft' Covered Slab Floor, 3.500" thick at Bedroon 2 HIGH MASS Design - Verify,ThermalMass:. 128.0 ftz Exposed Slab Floor, 3.500" thick at Bedroon 2 The.HVAC System HVAC 4:. riust serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se crate: hermostat "In.'addition the:air`flowrequirements and fan watt draw requirements in Residential Appendix RA -6 must be met. HIGH MASS Design. Verify,Thermal.'Mass 403.0 H-- Covered Slab Floor, 3.500" thick at Guest Bedroom HIGHWASS Design Verily Thermal Mass 72:0 ft' Exposed S/abiFloor 3 500 thick atrGuesFBedroom� .h The RoofR 38 Roof(R 38 2x14 16) includes credit for a' Radiant Barney that is Continuous meeting eligibility and installation criteria as specified in Residential A endix RA4.-2 2.'. .# *- «:: sa ..>a ufRIFICATIONr1 HERSKREQUIRED .. must Frec e ctor Item thls section:re ulre field testin andLor verification nspe v - o - .. coin"Ieted&CF-4R.form:.for;each"of,the..measures"listed.below•tor.final t6'b*e': fiver '' " The Cooling System Carrier 24ABC648/58CVX090 includes credit for a 12.5 EER Condenser.. A certified HERS rater_ must field verify the installation of the'correct Condenser The HVAC System HVAC 1:incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. " The HVAC System HVACTincorporates°HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria`: > ' The Cooling System Carrier 24ABC660/58CVX110 includes credit for a,1 2.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 & 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. ' The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ABC624158CVX070 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. . ;;Page Ener Pro 5.1 by E nerqySoft User Number: 6712 RunCode: 2011-08-17713:11:59 ID: 3 of 7 �`. Reg: 211-N0059489A-000000000-0000 Registration Date/Time: 2011/10/19 17:98:50 HERS Provider: CalCERTS, Inc Electronically Filed by.Tim Scott and Authenticated�at`CalCERTS.com - 10/19/2011 ' Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 10/19/2011 PERFORMANCE CERTIFICATE: Residential (Part,3 of 5) , CF -1 R Project Name Building Type 10 Single Family ❑ Addition Alone Date Ames Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 10/19/201 ANNUAL ENERGY USE SUMMARY - Standard Proposed Margin TDV kBtu/ft2 r Space Heating 4.54 3.39 1.14 Space Cooling 58.76 48.86 9.90 Fans 12.05 14.91 -2.86 Domestic Hot Water 7.73 5.20 2.53 Pumps 0.00 - 0.00 0.00 Totals 83.08 72.37 10.71 .Percent Better Than Standard: 12.9 BUILDING COMPLIES = HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (SM 237 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S K9 1,303 227 Fuel Available at Site: Natural Gas (NM 1,285 265 Raised Floor Area: o (NE) 1,366 491 Slab on Grade Area: 4,716 (SE) 1,377 211 Average,Ceiling Height-�11.4 Roof 4,716 0 Fenestration Average U Factor: 0'39 TOTAL: 1,194 ,. Avera e SHG'C. >' . 0.39Fenestration/CFA Ratio: 25.3 °i REMARKS 3 .:.'^'°' - r •� ..�.;4 �.�, 's+ '.. 7 ,t.€� g �'i ., � l{3 F l� it t f' � � d � 3q� �.�'�eSr � � ���u "' Y '."n••ay..u.-,..1_.. . i } �,� _'� i �4�s a'i '` �xf �*r�. .. �{�.' iia. ��`��'�•tr X;�, : � xS .,�%��.�sxx �. .... .a .3k.? .J' . . y._ Px i6 v P,,:Zc^"•:kry .=3 .., � YT i yt •�. '�, "[� , Yd �'. 'i, '}^,.r STATEMENTOF COMPLIANCE hal � .:. •r This.certificate of compliance,:�lists, the building features and specifications needed to comply with Title 24'1 Parts the'Administrative Regulations and Part 6 the Efficiency Standards of h6'.California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. . Documentation Author Company Scott Design and Title 24, Inc, ' 10/19/2011 Address 77-085 Michigan Drive Name Tim Scott Ci /State/ ip Palm Desert, Ca 92211 Phone (760).200-4180 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or.Owner (per Business & Professions Code) Company Helton,'DBFord & Associates Address 1261 N. Big Spring Street Name Dave Helton City/State/Zip Anaheim, Ca 92807 Phone (909) 957-4550 Signed License # Date Ener Pro 5.1 by Ener Soft User Number: 6712 • RunCode: 2011-08-17T13:11:59 ID: Page 4 of 7 Reg: 211-N0059989A-000000000-0000 Registration Date/Time: 2011/10/19 17:98:50 HERS Provider: CalCERTS, Inc i Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 10/19/2011 Electronically Signed,at CalCERTS.com by David W Helton (Helton, Deford & Associates) 10/19/2011 CERTIFICATE OF COMPLIANCE:, Residential (Part 4 of 5) . CF -1 R Project Name Ames Residence 1.. Building Type 0 Single Family ❑ Addition Alone - ❑ Multi Family ❑Existing+ Addition/Alteration Date ' 0/19/2011 OPAQUE SURFACE DETAILS Surface U- , Insulation Joint Appendix . Type Area Factor Cavity Exterior Frame Interior Frame Aim Tilt Status 4 Location/Comments Roof 1,297 0.026 R-38 .0 20 New 4.2.1-A9 Zone 1 Master Suite Wall 520 0.069 R-21 0 90 New 4.3.1-A6 Zone 1 Master Suite Wall 233 0.069 R-21 90 90 New 4.3.1-A6 Zone 1 Master Suite Wall 253 0.069 R-21 180 90 New 4.3.1-A6 Zone 1 Master Suite Wall 187 0.069 R-21 270 90 New 4.3.1-A6 Zone 1 Master Suite Slab 430 . 0.730 None 0 180 1 New 4.4.7-A1 ' Zone 1 Master Suite Slab' 867 0.730 None.. 0 180 New 4.4.7-A1 Zone 1 Master. Suite Roof 2,579 0.026 R-38 0 _ 20 New 4.2.1-A9 ' Zone 3 & 4 GreaUMornin , Wall 387 0.069 R-21 0 90 New 4.3.1-A6 Zone 3 & 4 GreaUMornin , Wall, 386 0.069 R-21 90 90 New 4.3.1-A6 Zone 3 & 4 Great/Morning Wall 571 0.069 R-21 180 90 New 4.3.1-A6 . Zone 3 & 4 GreaUMorning, Wall 384 0.069 R-21 270 90 New 4.3.1-A6 Zone 3 & 4 GreaUMornin , Slab 2,138 0.730 None 0 180 1 New 4.4.7-A1 Zone 3 & 4 GreaUMornin , Slab 441 0.730 None 0 180 New 4.4.7-A1 Zone 3 & 4 GreaUMornin , Roof 365 0.026 R-38 0 20 New 4.2.1-A9 Zone 3 & 4 GreaUMornin . Wall 65 0.069 R-21 90 90 New 4.3.1-A6 JZone 3 & 4 GreaUMornin . FENESTRATION SURFACE DETAILS • . . ID T e Area -�/-U-Factor_ ..SHGC2 Aim Status Glazing Type Location/Comments 1 Window 20.0: 0:390 NERC 0.39 NFRC 0 New Clad Wood Doors Zone 1 Master Suite' 2::.' Window... 6;0 ' 0:390.'NFRC 0.39 NFRC 0 New Double non-metal tinted Zone 1 Master Suite 3 :; Window4 = . 33:0: , 0.390, 'NFRC: - 0.39 NFRC _ 0 New Double non-metal tinted Zone 1 Master Suite 4.• +- Window ; , :1'-,6.0' °::0:390 :NF) C:. 0.39 NFRC 0 New Double non-metal tinted Zone i Master Suite 5 �z Window _ :� •4 ; 41.3 0.390 NFRC ; S •,:0.39; NFRC •. ;90 New ._ :, Double, non metal tinted ,-„„. ;: Zone 1 Master Suite 6 Window';,', "` 1104.01 0.390 NFRC .7;w 0.39'ONFRO,r k'90 New.t IClad'WoodDoors ,:at ti i Zone 1 Master Suite 7 ;Windowry;i ?'�6.0 0,390 NFRC,?; P0.39 _ . w .18a New ='y •Double,non-metal tinted . Zone.lWasterSuite 8, -Window 6.;0; i).39Q.'NFRC£ =v' -"0.39 `x;180; New 'Double:non=metal hntetl R^ Zone.a Master Suite9 Window is 96.`010.390 NFRC � ;039; F' ;270 ,New 3;A � CladWoodDoors �`��a Zone t.Master Suite^'r ; 10 ; Window::;: ,�'j96.0' ,0.390 NFRC A' 0.39' 0 rNewr�, Clad: Wood.Doors, ti .. St,. Zone 3 &''4 GreaUMornirig/Kil.,i Windows ,6.0: X0.390 NFRC 0.39:,�A' New.. ' bouble.non-metal tinted;` ,4`i Zone3 &`4'Great/Morning/Kid12'' Window#1' x80:0 � 0.390 NFRC _ 0.39 , n0 New. � � .V :Clad. Wood Doors ,° Zone 3 & 4 GreaUMorning/KiU 13 ;: Window ."_ 6.0; ,':0.'390 NFRC . ,:. 0:39 NFRC ."0 New Double non-metal tinted':' Zone 3 & 4 GreaUMornin /KiU 14aF Window bl _ ;220.0-.`.0.390 NFRC: 0.39 NFRC 901 New I Clad Wood Doors Zone 3 & 4 GreaUMorning/KiU 1531 Window.; .196:0: =-0:390: NFRC: 0.39 NFRC 901 New I Clad Wood Doors Zone 3 & 4 GreaUMorning/KiU 16.:; Window'.' ' ' 72.0 k.• 0.390 NFRC. 0.39 NFRC 180 New Clad Wood Doors Zone 3 & 4 GreaUMorning/KiU (1) U -Factor Type X116 A = Default Table from Standards, NFRC =Labeled Value 2 SHGC T e:. "s.:t t6 B =Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAIL=S Window Ove hang Left Fin Ric ht Fin ID Exterior Shade Type SHGC. .H t Wd Len H t LEA RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 . 2 Bug Screen 0.76 ,. 3 - Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 • 6 Bu Screen 0.76 8.0 13.0 8.0 0.1 8.0 8.0 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bu Screen t 0.76 8.0 -12.0 8.0 - 0.1 8.0 8.0 10 Bu Screen 0.76 8.0 12.0 6.0 0.1 6.0 6.0 ' 11 Bu Screen 0:76 r 12 - Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 10.0 22.0 12.0 0.1 12.0 12.0 15 Bug Screen 0.76 16 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2011-08-17713:11:59 ID: Page 5 of 7 M n" Reg:,211-N0054484A-000000000-0000 Registration Date/Time: 2011/10/19 17:48:50 HERS Provider: CalCERTS, Inc t_� Electronically Filed by Tim Scott -and Authenticated at CalCERTS.com - 10/19/2011• ' �,- Electronically Signed at Ca10ERTS:com by David W Helton (Helton, Deford & Associates) 10/19/2011 CERTIFICATE OF COMPLIANCE: -°Residential`_ , (Part 4 of 5) CF -1 R Project NameBuilding Ames Residence Type , 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 0/19/2011 OPAQUE SURFACE DETAILS _ _Y Surface. U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Aim Tilt I Status 4 Location/Comments Wall 117 .0.069 R-21 180 90 New 4.3.1-A6 Zone 3 & 4 Great/Morning, Wall 278 0.069 R-21 - _ . 270 90 New 4.3.1-A6 Zone 3 & 4 Great/Morning, Slab 237 0.730 None 0 180 New 4.4.7-A1, Zone 3 & 4 GreatlMomn 22, Slab 128 0.730 None 0 180 New 4.4.7-A1 Zone 3 & 4 Great/Morning, Roof 475 0.026 R-38 0 20 New 4.2.1-A9 Guest Bedroom Wall _ 113 0.069 R-21 0 90 New 4.3.1-A6 Guest Bedroom Wall 192 0.069 R-21 90 90 New 4.3.1-A6 Guest Bedroom Wall 225 0.069 R-21 180 90 New 4.3.1-A6 Guest Bedroom Wall 228 . 0.069. R-21 270 90 New . 4.3.1-A6 Guest Bedroom Slab 403 0.730 None 0 180 New '. 4.4.7-A1 Guest Bedroom Slab . 72 0.730 None 0 180 New 4.4.7-A1 Guest Bedroom FENESTRATION SURFACE DETAILS . - ID Type Area .:� U -Factor:. - SHGC Azm Status Glazing Type Location/Comments 17 Window 8.0:' 0.390. NFRC 0:39 NFRC 180 New • Double non-metal tinted Zone 3 & 4 Great/Morning/Kid 18, ." Window:: _. •=.80:0:.:.0.390 NFRC 0.39 NFRC - 180 New Clad Wood Doors Zone 3 & 4 Great/Morning/Kit/ 19 = Window 6.0 ~.0.390 NFRC. 0.39 NFRC 180 New Double non-metal tinted Zone 3 & 4 Great/Mornin Kit/ 20. ' Window ; ; ` Q3'5' :: 0.390 NFRC.':'. 0.39 NFRC 270 New Double non-metal tinted Zone 3 & 4 GreabMorning/Kit/ 21;t Window : :90.0 0.390. NFRC"::1 0.39, :NFRC .v ;, :-,270 .New _� .. Clad Wood Doors � Zone 3 & 4 Great/Morning/KiU :.. :_. 22.:; Window,;.'":..' '5,16.5 0.390 NFRC is X0 39' NFRC 90 Mw Gam; Double noh-metal 6rited r " ,'Zone 3 & 4 GreabMorning/Kit/ 23 > Window;'-. X 33.0 0.390 NFRC, t r*6.39 39 NFRC : 7' sx180 `New, - Double non-metal tinted !f Zone 3 &.4 Great/Morning/Kitl 24 Window i_ ' 60 -0.390,. NFRC:'..�,10.39 NFRC>'c r :O.Newk D6ubi4non-metattinted;? Guest Bedroom 25 Window-"' 6'0 x.0.390 .NFR• C t'T c :0.39 NFRC „3c0; ,New wa Double;non-metalamted;' ; •Guest Bedroom 26 ' Window:: :of113.51 9,0.390 NFRC '1'.,0.39NFRC A4 t;i #90, :New ;.1 r Doublehon-metal tinted. v _'Guest Bedroom '- !,r'L.13 5; 0.390 NFRCI1t��•.*. ,..0.39 NFRCAt : , 270 .New Double.non=metal tinted GuestB4dr6omi0A* Window 3 0:390 NFRCI +x•0.39 NFRC.' :S 7270 New "m Double non-metal tinted �:': � Guest Bedroom r27.:.,lNindow (1) U -Factor Type , x.116 A'= Default Table from Standards, NFRC =Labeled Value 2 SHGC Type: 7,16 8' =Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ,Window Ove hang Left Fin Right Fin ID Exterior Shade T e' SHGC H t Wd Len H t LExt RExt Dist Len H t Dist , Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 8.0 10.0 6.0 , • 0.1 6.0 6.0 ' 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 " 23, Bug Screen 0.76 ' '24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 ` 27 Bug Screen _ 0.76 28 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 6712 Run Code: 2011-08-17713:11:59 ID: Page 6 of 7 "� Reg: 211-N0059989A-000000000-0000 Registration Date/Time: 2011/10/19 17:98:50HERS Provider: Ca10ERTS,'Inc ' Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 10/19/2011 Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates).10/19/2011 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name. Ames Residence Building Type � Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11011912011 BUILDING ZONEINFORMATION Floor Area ft S stem Name Zone Name. New Existin Altered Removed Volume Year.Built HVAC 1 Zone 1 Master Suite 1,297 13,359 HVAC 2 & 3 Zone 3 & 4 Great'MornlKitlDinlFc 2_,579 31,980 Bedroon 2 365 3,650 HVAC 4 Guest Bedroom 475 4,750 Totals .4,7161 0 0 01 1 HVAC SYSTEMS System, Name QtV 9 Heating Type. Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 " ` * R..' . a - 1 § Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVA8 3 2 Ceritral Furnace 80% AFUE Split Air Conditioner 15.2 SEER Setback New HVAC 4': . -. 1 > ;Central Furna'&6 80%AF.UE"S lit AirConditione"rte 15:5`SEER: Setback'. .. New _ S4"ei, 'tri HVAC DISTRIBUTION {¢, ;:,'Duct+L Ducts' S stem Name �. _:"Heatin _ ..Conlin._... Duct Location • R -Value Tested. Status _. Ducted Attic, Ceiling Ins, vented 8.0 - New HVAC 2:& 3'., ,, :- Ducted a Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 4rZ;; Ducted .a->'. Ducted Attic, Ceiling Ins, vented 8.0 New ❑ WATER HEATING SYSTEMS:` S stem Name Qty. Type Distribution Rated 'Input Btuh Tank Cap. al Energy, Factor or RE Standby Loss or Pilot Ext. Tank . Insul. R- Value Status Bradford -White M -1-100T6 . 1 _ Large Gas All Pipes Ins 85,000 100 0.80 0.00 % 0.0 New MULTI -FAMILY WATER HEATING DETAILS - HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o v Q S stem Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ , Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2011-08-17713:11:59 ID: Pae 7 of 7 i. Reg: 211-N0054484A-000000000-0000 Registration Date/Time: 2011/10/19 17:48:50 HERS Provider: CalCERTS, Inc I r Summit Structural Engineering PO BOX 2618 902 Baycolt Way McCall, ID 83638 (208) 634-8148 Fax (208) 634-6395 October 27, 2011 Spates Fabricators 85=435 Middleton Street i ' tt Thermal CA 92274 OCT 2 2011 Attn: Truss Designer Subject: Roof Truss Shop Drawings and Calculations Hideaway, Lot 230 Ames Residence 53-672 Via Palacio La Quinta, 'CA Dear Truss Designer; The roof truss drawings by Spates Fabricators for the subject project were received by. our office on October 27, 2011, and is approved. The submittal has .been reviewed for general conformance to the design concept of the project structural plans. The fabrication processes, techniques of construction, dimensions, and quantities are not a part of this review. Since the shop drawings were -reviewed only for general conformance with the structural plans, unless variations from the structural plans have been .clearly indicated, we may not have listed them. Our review of these drawings does not relieve the truss engineer and the'framing contractor from complying with the structural plans. Yours truly, SUMMIT STRUCTURAL ENGINEERINGCITY OF LA QUlNTA BUILDING & SAFETY DEPT. APPROVED FOR C NSTRUC ION Benjamin' Herbst, P. E. 0 1 � DA12 I BY- 7Yb BH��"�3� 0201 l jobfiles\SV-385\385_truss1.doc Residential, Commercial, Industrial, Land Development