Loading...
04-4117 (SFD)T4hf 4 4 a" P.O. Box 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING PERMIT BUILDING & SAFETY DEPARTMENT (760).777-7012 FAX (760) 777-7011 INSPECTION REQUESTS (760) 777-7153 Application Number . . . . . C170-4-7-0-0-0-0 4117- ---- — Date 1/26/05 Property Address . . . . . . 53716 VIA PALACIO APN: 772-560-053- - - Application description . . . DWELLING - SINGLE FAMILY DETACHED Property Zoning . . . . LOW DENSITY RESIDENTIAL Application valuation 397007 Owner Contractor ------------------------ NAGY DALE/KATHY ------------------------ EASTON BUILDERS CORPORATION 7609 W. EMERALD P.O. BOX 3235 BOISE H.O PALM DESERT CA 92261 BOIS G=�1 83704 JAN 2 % 2005 WCC: STATE FUND WC: 174457004 09/01/05 CSLB: 755163 10/31/06 CITY OF LAQIUINTA FIMAMCE DEPT. CCC: B --------- ------- - -------- Structure Information ---------7--------------- Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/LONG <=10 Flood Zone . . . . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 # BEDROOMS 3.00 FIRE SPRINKLERS NO GARAGE SQ FTG 1034.00 PATIO SQ FTG 1790.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 4368.00 ------------------------------------------------------------------ Permit BUILDING PERMIT ---------- Additional desc Permit Fee . . . . 1682.50 Plan Check Fee 1093.63 Issue Date . . . . Valuation . . . . 397007 Qty Unit Charge Per Extension .BASE FEE 639.50 298.00 3.5000 THOU BLDG 100,001-500,000 1043.00 ---------------------------------------------------------------------------- Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee . . . . 203.56 Plan Check Fee 50.89 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 4368.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 152.88 1034.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 20.68 P.O. Box 1504 • VOICE (760) 777-7012 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760)•777-7153 BUILDING & SAFETY DEPARTMENT Application Number: UY �- Applicant: Applicant's Mailing Address: I hereby affirmunder p alty of perjury that I am Code, and my License in full force and effect. fUcense CI s Date Co ract Date: Architect or Engineer: Architect or Engineer's Address: Lic. No.: ING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION provisions of Chapter 9 /(commencing with Section 7000) of Division 3 of the Business and Professionals se No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury th I am empt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to const , Iter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant.for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date ' WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I ha and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is u d Mill ers' c pensation in rice carrier an �qli umber ara, Carrier- 't 1 ! Po cy umber / lR }r j / r7 r7 f certify that, in the performance of - the_ r for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, a a r e that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall rforthwith comply with those —vi o Date rL� 0 f Applicant WARNIN : FAILURE TO SECURE WOR ERS' CIVIL FINES UP TO ONE HUNDRED THO A SECTION 3706 OF THE LABOR CODE, INT )MPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN ', AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lenders Address APPLICANT IMPORTANT Application is hereby made to the Director of Building and Safety fo 1. Each person upon whose behalf this application is made, each perso issued as a result of this application, the owner, and the applicant, e i officers, agents and employees for any act or omission related to the 1 2. Any permit issued as a result of this application becomes null and v s cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information construction, and hereby authorize representatives of this count to enter n Date Signature Applicant or Agent): ACKNOWLEDGEMENT iI subject to the conditions and restrictions set forth on this application. at w se request and for whose benefit work is performed under or pursuant to any permit h agre s lo, and shall, defend, indemnify and hold harmless the City of La Quinta, its be ng performed under or following issuance of this permit. if w is not commenced within 180 days from date of issuance of such permit, or ct. agree to comply with all city and county ordinances and slate laws relating to building dab ve-mentioned property for inspection purposes. Page 2 Application Number . . . . . 04-00004117 Date 1/26/05 Qty Unit Charge Per Extension 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 ---------------------------------------------------------------------------- Permit GRADING PERMIT Additional desc Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Permit MECHANICAL Additional desc . . Permit Fee . . . . 168.50 Plan Check Fee 42.13 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 6.00 9.0000 EA MECH FURNACE <=100K 54.00 6.00 9.0000 EA MECH B/C <=3HP/100K BTU 54.00 6.00 6.5000 EA MECH VENT FAN 39.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 ---------------------------------------------------------------------------- Permit PLUMBING Additional desc . . Permit Fee . . . . 214.50 Plan Check Fee 53.63 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 19.00 6.0000 EA PLB FIXTURE 114.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 6.0000 EA PLB ROOF DRAIN 12.00 3.00 7.5000 EA PLB WATER HEATER/VENT 22.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 12.00 .7500 EA PLB GAS PIPE >=5 9.00 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SFD - 4368 SQ.FT. SINGLE FAMILY RESIDENCE. R-3 OCCUPANCY, TYPE V-N CONSTRUCTION. 2001 CODES. MUP FOR GUEST SUITE REQUIRED. PERMIT DOES NOT INCLUDE BLOCK WALLS, FENCES. POOL OR SPA. Page 3 Application Number . . . . . 04-00004117 Date 1/26/05 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 492.51 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 109.36 DIF FIRE PROTECTION -RES 97.00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 39.70 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total Charged Paid 2284.06 .00 1240.28 750.00 3046.57 .00 6570.91 750.00 Credited Due .00 2284.06 .00 490.28 .00 3046.57 .00 5820.91 Building Address / IU •4 4 " P.O. BOX 1504 ID78-495 CALLE TAMPICO 44 Ar /n LA QUINTA, CALIFORNIA 92253 Mailing Address WeQ9 WE�7 Lmeralp City Zip Tel. Y�►SE z i> n 3-70 `-1ZIQR -- 3� -74t0o el Address ty State Lic.I City & Classif. Lic. # Arch., Engr., Designer Address Z.— W,n•}er's RA 51e• A 7W -7116- 40&8 City Zip State p iLic.#C Zy D(47 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter. improve, demolish, or repair any Structure, prior to *its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code. or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). (_11 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner or property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) II I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractors) licensed pursuant to the Contractor's License Law.) 1! 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company Cl Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed If the permit is for one hundred dollars ($700) valuation or less.) I certify that in theperformance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, alter making this Certificate of Exemption you Should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip otl- 4 17 APPLICATION ONLY JILDING: TYPE'CONST.y N�­ OCC. GRP.5 eAlP P. Number 7 Z•I5760—dS� J :gal Description 4:1`7 ?Z9 I "TkA T •79 6 9 Ll- Z Sq. Ft Descriptions 1008 No. No. Dw. 2 Stories Units J New Add ❑ Alter ❑ Repair ❑ Demolition ❑ imated Valuation I PERMIT 1 110 ` ~ I AMOUNT Plan Chk. Dep. 2, 62 Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from per P•np� Side Street Se ba •k from Cher Lin Side Setback f unP oD� eir v' Ine 111111 FINAL DATE Issued by: Validated by: Validation: WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE Date 1/18/05 No. 26789 Owner Dale & Kathy Nagy Address City Zip Tract # Type Single Family Residence CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # Jurisdiction Permit # Study Area No. of Units 'Zno BERMUDA DUNES rn RANCHOMIRAGE ID INDIAN WELLS .� G✓' PALM DESERT ��� . LA QUI TA � o01 y 772-560-053 La Quinta 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 53716 Via Palacio 4490 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility.fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.24 X 4,490 S.F. or $10,057.60 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Wells Fargo Bank - Curt Dunham Check No. 0599903198 Name on the check Telephone 346-5076 Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exempted by Sharon MCGllvrey Payment Recd $10,057.60 Over/Under Signature C NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting 01/19/05 15:20 FAX 909 275 5204 _ 1ST AMERICAN TITLE INS.. 2002 Recording Requested By and When Recorded Return to: Brian L. Ballard liawicy T roxell Ennis & Hawley LLP 877 Main Street, Ste. 1000 Boise, 11D 83702 Mail Tax Notices to: Community PropeRies/Amrnon, LLC 7609 W. Emerald Street Boise, ID 83704 DOC is 2003-282488 0M14/21Q 04:0011 Fee:18.H Page Iof4 Reasrded in Official, Records County of Riverside Gary L, orso Roessler, County Clark 8 Recorder 11111111111111111111111 lilt 111111111 gill Ill 11 M g U v,Ice tl,>!E 011 vC4n MORA EMF MISC J� CIYY 1onG I K"'.. W. DOCLJMENT TRANSFER TAY'. & % 10 P XX Computed on the COASideration or value of property conveyed; OR / ` Computed on the consideration or value less liens or encwxtbrances remaining at the tim:: of sale. Signature of Declarant of Agent determining tax - Firm Narne GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, WESTERN INTERMEDIARY EXCHANGE ACCOMMODATION TITLEHOLDER, INC., an Idaho corporation ("Grantoe ), hereby GRANT(S) to COMMUNITY PROPERTIES/AMMON, LLC, an Idaho limited liability company ("Grantee" }, the real property located in the City of La Quinta, County of Riverside, State of California, described as; See Legal Dcscinption attached hereto and incorporated herein as Exhibit "A". SUBJECT TO all maticrs of record, including, without limitation, the covenants and agreements described in Exhibit. "A" attached hereto. GRANT DEET - I Description: Riverside, CA Document-Year.DoclD 2003.262488 Page: 1 of 4 Order: 01-19-2005 02-13-57 PM Comment: KING li- 05"5=011901WA 01/19/05 15:20 FAX 909 275 5204 1ST MIERICAN TITLE INS. 100o.3 Dated. March 2003. WESTERN INTERMEDIARY EXCHANGE ACCOMMODATION TITLEHOLDER, INC., an Idaho corpo�ption By. David G. Ballard, President STATE OF IDAHO } s.s., County of Ada ) On this � day of Mauch, 2003, before me, r� oc dsa,J , a Notary Public in and for said State, p!:rsonally appeared David G. Ballard, known to me to be the President of WESTERN INTERMEDIARY EXCHANGE ACCOMMODATION TITLEHOLDER, INC., the corporation that executed the within instrument or the person who executed the instrument on bc;half of said corporation, and acknowledged to me that such corporation executed the same. IN WITNESS WHERE(7F, I hate hereunto set my hand and affixed my official seal the day and year first above written. r,•�!�'� t7p��,. Lary Public for the State of Idaho Residing at My commission expires -200 44 INE 111111111 1111111111111114 Z of 4 GRAN'1 DEED - 2 0s605=1.001:6.1 Description: Riverside, CA Document -Year DoclD 2003.262488 Page: 2 of 4 Order: 01-19-2005 02-13-57 PM Comment: KING 01/19/05 15:21 FAX 909 275- 5204 _1ST AMERICAN TITLE INS. 0004 v EXHIBIT "A" Lc.g-al Description of Real Prpperty PARCEL NO. 1.: Lot 229 (the "Let') of Amended Tract No. 29894-2 as shown on a Subdivision Map (the "Map") recorded on December 12, 2002, in Book 327, Pages 56 to 88, inclusive, of Maps, in the Office of the Riverside County Rs;corder. EXCEPTING AND RESERVING THEREFROM TO ND LA QLrDNTTA PARTNERS, LLC, a Delaware limited liability company ("ND La Quints Partners"), and its successors, assigns, invitees, licensees and omployces, together with the right to grant and transfer all or a portion of the same, all ease.inerds and rights for access, ingress, egress, encroachment, maintenance, drainage, support, attMd for other purposes over the Association Maintenance Areas and other portion of the Lot, rese rued to ND La Quinta Partners in the following instruments: 1. The Amended ,and Restated Declaration of Covenants, Conditions and Restrictions and Reservation of Easements for The Hideaway Owners Association (as amended or supplemented, the "Declaration"), recorded on December 13, 2002, as Instrument No. 2002- 7459938, of Official Records of iverside County, California (the "Official Records"); FURTHER REST RVING THEREFROM, the right to enter the Lot for a term of twelve. (12) months from February 4, 2003, to complete and repair any improvements or landscaping located thereon as determined necessary by ND La Quinta Partners, in its sole discretion, in order to comply vdth requirements for the recordation of the Final Tract Map, the grading of said Tract and/or in compliance with the requirements of applicable governmental agencies. Such entry by ND La Quinta Partners shall be preceded by reasonable notice to Grantee before such entry. If this reservation of right of entry is not complied with by Grantee, ND La Quinta Partners may e:'iforce this right of entry in a court of law. Grantee shall be responsible for all damages arising out of said breach including attorneys' fees and courl costs. This reservation of right of entry shall automatically expire on February 3, 2004. PARCEL 2: Nonexclusive easementi; for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as descrlied in the Declaration. SUBJECT TO: assessments, Nondelinquent general, special and supplemental real property taxes and 94n*e2&fi3 90 - VOR 11,1111 fill 11111111111111 Hill 1111 IN . 3 of 4 EXHIBIT "A" TO GRANT DED) - 1 06006.0091.6904 5.1 Description: Riverside, CA Document -Year VoclD 2003.262488 Page: 3 of 4 Order. 09-19-2005 02-13.57 PM Comment: ;UNG 01/19/05 15:22 FAX 909 275 5204 1ST AMERICAN TITLE INS. 2. All other covenanls, conditions, restrictions, reservations, easements, rights and rights-of-way of record irrcludin;, without limitation, the Declaration and the Map for Tract No. 29694-2. Grantee, by acceptance turd recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in this Grant Deed, (b) grants to ND La Quints Mariners and The Hideaway Owners Association such powers and rights as are set forth in the Declaration, and (c) accepts, covenants and agrees to be bound by and assume performance of all of the applicable provisions and requirements set firth in the Declaration, including Section 13.15 establishing the procedure for resolving disputes with ND La Quinta Partners, and the notice, which provisions and requirements aro acknowlcdl;ed to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be performed by Grantee under the Declaration. The restrictions on use and occupancy of the Lot are set Corth in the Dec' aration to which this Grant Deed is specifically and expressly made subject. GRANTEE HEREBY A::CI✓PTS AND APPROVLS THE FOREGOING, granting unto ND La Quinta Partners and The i iideaway Owners Association such powers and rights which are set forth in the Declaration defined above, on March IL 2003. COMMUNITY PROPERTIES/Al\MION, LLC, an Idaho limited liability -)company Dale F STATE OF IDAHO ) County of Ada } On this i/ i day of March, 2003, before me,f. Gam•• d a Notary Public in and for said St,r-te, personally appea-Ted Dale F. Nagy, known or identified to me to be the manager of the limited liability company of COMMUNITY PROPERTIES/AMMON, LLC, and the manager who su!ascribed said company name to the foregoing instrument, and acknowledged to me that he e=.-utcd the same in said company name_ IN WITNESS WHEREC ,F, I have hereunto set my hand and affixed my official seal the day and year in this certificate First above written. 060Uages F. CA2,4_ i M 49 .0 v Of sedges EXHIBIT "A" TO GRANT DEEID - Z ovary Public for the State of Idaho Residing at My commission expires Description: Riverside, CA Document-Year,Voc1D 2003.262488 Page: 4 of 4 Order: 01-19-2005 02-13-57 PM Comment: KING 11111111pl 94/1V9007 '� Zoo5 awas.uwi .6ec � u.� D RECORDING REQUESTED BY: City of La Quinta - City Clerk's Office PO Box 1504 La Quinta, CA 92247-1504 WHEN RECORDED PLEASE MAIL TO: Dale Nagy P.O. Box 3235 Palm Desert, CA 92261 DOC a ZOOS-OOS 1521 01/19/2005 08:00A Fee:NC Page 1 of 4 Recorded in Official Records County of Riverside Assessor, County Clerk 8 Recorder { III III! 1111111 III 11111 Ilill III IIII IIIII III IIIII illi IIII ' M-� II PA � I SIZE I OA I PCOR I NOCOR SMF MISC. A I R I L II 1 I COPY I LONG IREFUND . I NCHG COVENANT AND AGREEMENT RESTRICTING THE USE OF THE RESIDENCE AT 53-716 VIA PALACIO, LA QUINTA, CALIFORNIA This covenant and agreement are made and executed this 20th day of V�- December, 2004 -by Dale Nagy, as the record owner(s) of the property described herein. The City of La Quinta, a Municipal Corporation, is hereby made a party to this agreement for the purposes set forth below. The undersigned hereby certifies that he/she is the property owner of the following described real property in the City of La Quinta, County of Riverside, State of California: o P&O le - Lot 229 of Tract 29894-2; as per record map on file with the Recorder of Riverside -County In consideration of the City of La Quinta issuing a. building permit for certain improvements which will be constructed on said property, the undersigned does hereby covenant and agree to and with said City to restrict the use of said property as follows: 1. The guest house may not be rented nor sold independent of the main single family residence (Minor Use Permit No. 2004-570); 2. No kitchen or cooking facilities shall be constructed in the guest house per the provisions of Chapter 9.30.030 (RL Zone District) and 9.60.1 10 (Guest Houses) of the La Quinta Municipal Code; 3. All on-site facilities are intended for the sole occupancy of the property owner(s), guests, and caretakers (i.e., a maid and/or housekeeper, etc.); and, 4. The guest house shall be used primarily as a sleeping facility, and shall be maintained in accordance with all zoning and other codes as set forth in the La Quinta Municipal Code, as may be amended from time to time. This covenant and agreement shall run with the land and shall be binding upon future owners, their successors, heirs, or assigns, and ourselves, and shall continue in effect while said accessory building remains on the real property or unless otherwise released by the authority of the City of La Quinta. All leases of said dwelling and/or property shall be subject to this restriction. This agreement shall be entitled to the remedy of injunctive relief in addition of any remedy in law or equity. This covenant and agreement and the provisions hereof are irrevocable, except by the written consent of all parties to the agreement, including the City of La Quinta, a municipal corporation. The City shall have the right to enforce each and every provision hereof and .the parties agree that the agreement shall not be rescinded, revoked, modified, or otherwise amended or changed, without the expressed written consent of the City first being obtained.. In the event That the owners, their heirs, assigns or successors in interest, shall fail to perform any obligation hereunder, they hereby agree to pay all costs and expenses incurred by the City of La Quinta in securing performance of such obligation, including attorney's fees. By: 1 . 2. 3. Dated: f- 3 - zeas7 r- X J /� Thomas P. Genovese City Manager/Interim Community Development Director City of La Quinta Date ALL PURPOSE NOTARY ACKNOWLEDGMENT(S) MUST BE ATTACHED IN 8 1/2 X 11 " FORMAT, FOR EACH SIGNATURE. State of California County of Riverside On December 21, 2004 before me, Regenia Hensley, Notary Public, personally appeared THOMAS P. GENOVESE personally known to me to be the person whose name is subscribed to the within instrument and acknowledged to me that he executed the same in his authorized capacity, and that by his signature on the instrument the person or the entity upon behalf of which the person acted, executed the instrument. WITNESS my hand and official seal. REG IA HENSLEY Notary Public Commission # 1521423 Expiration: October 23,-2008 (Seal) REGENIA HENSIF,Y.. Cornet alon 8 1521423 •• . Notary Pubk - CoNforrdo Rfverslde County wN Corrin. E0m Oct 23, 2006 State of Idaho Ada County On January 3, 2005, before me, Karen Riley, Notary Public, personally appeared DALE F. NAGY personally known to me to be the person whose name is subscribed to the within instrument and acknowledged to me that he executed the same in his authorized capacity, and that by his signature on the instrument the person or the entity upon behalf of which the person acted, executed the instrument. WITNESS my hand and official seal. f KAREN RILEY Notary Public Expiration: December 12, 2008 4411.11 •. 8,,, •••�•• * v%0TgR.J& O"qb February 3, 2005 Mr. Curt Dunham Easton Builders Corp. 73725 El Paseo, Ste. 24-B Palm Desert, CA 92260 Re: Nagy/Inspection — Setbacks Lot 229 at 53716 Via Palacio Deleted: Howard/Pre-Construction '------------------------------ ------------- ----- ---- --- - - - --- (Meeting¶ Dear Mr. Dunham: i Lot 170 at 80630 Via Pessoro The setback inspection has been completed at 229 on Via Palacio. Based on the strings set up in the field, the residence conforms to the approved setbacks for this lot. Photos of the measurements are in the file for future reference. Thank you for your compliance with this required inspection. I look forward to working with your team further on the construction of this home. Please call Brook Marshall at (760) 346-1161 with any questions or concerns. Sincerely, Hideaway Design Review Committee CC: DRC File Certificate of Occupancy � �I urILI Ct/ OF aw Building y p & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use: BUILDING ADDRESS: 53716 VIA PALACIO Use classification: SFD Building Permit No.: 04-4117 Occupancy Group- R3 Type of Construction: VN Land Use Zone: RL Owner of Building: EASTON BUILDERS Address: PO BOX 3235 City, ST, ZIP: PALM DESERT CA 92261 By: GARY SHOWALTER �! d' Date- 12-19-05 Building Official POST IN A CONSPICUOUS PLACE 179, ; TITLE 24 REPORT `Z v 40 T Title 24 Report for: Nagy Residence 53-74:8 Via`Palacio-�- The;t-lideaway. La Quinta, CA 92253 Project Designer: Kristi Hanson Architects, Inc. 72-185 Painters Path Suite #A Palm Desert, CA 92260 760-776-4068 Report Prepared By: Gina Rose G.R. Rose CAD Design 42335 Washington Suite F #330 Palm Desert, CA 92211 (760) 345-4859 Job Number: Date: 6/5/2004 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE , BY�'�T The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. I This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number. User Number: 5862 !lO�IC E! ce/D/- • 0 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Nagy Residence 6/5/2004 Project Title Date 53-717 Via Palacio - The Hideaway La Quinta Project Address Building Permit # G.R. Rose CAD Design (760) 345-4859 , Pian check I Date Documentation Author Telephone Computer Performance 15 Field Check I Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 4,490 fit Average Ceiling Height: 11.4 ft Total Conditioned Slab Area: 4_490f? Building Type: (check one or more) ® Single Family Detached ❑Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (East) 90 deg Number of Dwelling Units: 1.00 Number of Stories: 1 Component R-38 Roof (R.38.2xl4.16) R-21 Wall (W.21.2x6.16) Slab On Grade Slab On Grade Solid Metal Door Solid Wood Door FENESTRATION Floor Construction Type: ® Slab Floor ❑ Raised Floor Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) Wood 0.028 Exterior Roof Wood 0.059 Exterior Wall n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Metal 0.592 Exterior Door Wood 0.387 Exterior Door Shadino D®vices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Right (North) 41.6 0.53 0.43 Bug Screen ❑ X❑ ❑ X❑ Front (East) 268.0 0.45 0.43 Bug Screen ❑ X❑ ❑ X❑ Front (East) 166.0 0.60 0.49 Bug Screen ❑ X ❑ X❑ Left (South) 85.6 0.45 0.43 Bug Screen ❑ X❑ ❑ X❑ Left (South) 67.3 0.60 0.49 Bug Screen ❑ X❑ ❑ X❑ Left (South) 14.5 0.53 0.43 Bug Screen ❑ X❑ ❑ X❑ Rear (West) 49.6 0.45 0.43 Bug Screen ❑ X❑ ❑ X❑ Right (North) 67.1 0.45 0.43 Bug Screen ❑ X❑ ❑X❑ Right (North) 24.0 0.60 0.49 Bug Screen ❑ X❑ ❑ X❑ Rear (West) 7.1 0.53 0.43 Bug Screen ❑ X❑ ❑ X❑ Rear (West) 300.0 0.60 0.49 Bug Screen ❑ X❑ ❑ X❑ El 1:1 El Run Initiation Time: 0610510410:02:15 Run Code: 1086454935 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Pa e:3 of 44 s 0 • Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Nagy Residence 6/5/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnace 81 % AFUE Duffs in Attic 42 Setback Master Suite Central Fumare Central Furnace 81%AFUE Ducts in Attic 80% AFUE Ducts in Attic 42 Setback 4.2 Setback Living Area Guest Room 1 Nnne n/a Ductless / with Fan n/a Setback Garage Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 42 Sethack Master Suite Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Sethack Living Area Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback Guest Room 1 Room PTAC without Side Louvers 9.8 EER Ductless n/a Setback Garage WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standbyy Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss ( 0) R -Value A.O. SMITH FPS -75-230 Small Gas Recirrrrime+Temo 2 75,000 75 0.88 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 MAO, list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Kristi Hanson Architects, Inc. Address: 72-185 Painters Path Suite #A Palm Desert, CA 92260 T lepho e: 7sa 76-40 8 Li . 04 (si na re (date En rcement Agency Name: Title/Firm: _ Address: Telephone: Name: Gina Rose Title/Firm: G.R. Rose CAD Design Address: 42335 Washington Suite F #330 Palm Desert, CA 92211 Telephone: 60 3454859 signature) (da ) (signature/stamp) (date) Run Initiation Time: 06105/0410:02:15 Run Code: 1086454935 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. PageA of 44 0 Certificate of Compliance: Residential (Addendum) CF -1 R Nagy Residence 6/5/2004 Project Title Date pecial Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I plan I Fiald The HVAC System "Master Suite" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 238 sqft Exposed Slab Floor, 4.00" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 694 sqft Covered Slab Floor, 4.00" thick at Zone 1 The HVAC System "Living Area" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2467 sqft Exposed Slab Floor, 4.00" thick at Zone 2 The HVAC System "Guest Room 1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 75 sqft Masonry Veneer Exterior Mass, 2.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 356 sqft Masonry Veneer Exterior Mass, 2.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 126 sqft Exposed Slab Floor, 4.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 302 sqft Covered Slab Floor, 4.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 185 sqft Masonry Veneer Exterior Mass, 2.00" thick at Garage HIGH MASS Design(see C -2R) - Verify Thermal Mass: 310 sqft Masonry Veneer Exterior Mass, 2.00" thick at Garage HIGH MASS Design(see C -2R) - Verify Thermal Mass: 663 sqft Exposed Slab Floor, 4.00" thick at Garage HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field The HVAC System "Master Suite" incudes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Master Suite" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Living Area" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Living Area" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Guest Room 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Guest Room 1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Garage" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. I EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:5 of 44 1 41 Certificate of Compliance: Residential (Addendum) CF -1 R Nagy Residence 6/5/2004 Project Title Date pecial Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies Jflaeu VII me aueyuaGy ui the Speulal Jus[Inuaoon ano uouumentatron suomlttea. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS Plan I Field proviaer. r ne nr_ma rater must aocumen[ the nela verncation ana a18gnosuc tesang or mese measures on a torn LF -6R. Plan Field The HVAC System "Garage" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. I EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Paae:6 of 44 1 r • Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures X 4150(a): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturer's labeled R -Value. ❑'§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does i� not apply to exterior mass walls). [X]'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent ❑61500): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm(nch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and forth. ®§11r,17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. a§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures a§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. a§150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. § 1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:7 of 44 • . Mandatory Measures Checklist: Residential (Page 2 of 2) MF -IR NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or Initial applicable boxes or enter NIA If not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) 4150(m): Duds and Fans 1. Al duds and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; duds insulated to a minimum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with doth back rubber adhesive dud tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, dud board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain duds. Duds installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the duds. 3. Joints and seams of duct systems and their components shall not be sealed with doth bark rubber adhesive dud tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have bark draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between fitter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor. pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. FV §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ❑ §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 Iumanstwatt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. • 3.1 By EnergySoft User Number. 5862 Job Number. Page: Bof 44 Computer Method Summary (Part 1 of 3) C -2R Nagv Residence 6/5/2004 Projg'cl Title Date 53-717 Via Palacio - The HideawayLa I Project Address �— Quints Building Permit # G -R- Rose CAD Design (760) 345-4859 Documentation Author Telephone Plan Check/Date omn tt -r eetforna)1ce Compliance Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 4.53 3.52 1.02 Space Cooling 38.75 40.93 -2.18 Domestic Hot Water 6.35 4.25 2.10 Totals 49.63 48.69 0.94 Total Conditioned Floor Area: 4,490 ft2 Building Type: Single Fam Detached Building Front Orientation: (East) 90 deg Number of Dwelling Units: 1.00 Number of Stories: 1 BUILDING ZONE INFORMATION Zone Name Floor Area Volume Master Suite 432 Living Area 246 Guest Room 1 428 Garage 663 • OPAQUE SURFACES Solar n..+ Gains Y/N Type Area U -Fac. Azm. Tilt Roof 932 0.028 _0 0 y(all 644 0.059 _n 90 - Wall _19.4 0.059 SO g.0_ Wall 366 0.059 180 90 Wall 278 0.059 270 90 Roof_2 467 0.028_ n —a Wall 664 0.059 —0 90 Wall 867 0.059 _90 90 Wall 417 0.059 180 90_ Wall 574 0.059 270 g0_ Door 24 0.592 270 90 Roof 428 0.028 —Q 0 Wall 75 0.059 go —9a (all 356 0.059 180 gn Wall 250 0.059 270 9.0_ Rnof —6.63 0.028 n 0 Wall 301 0.059 a 90 DJDDf — 24 0.592 —a _9a Wall 185 0.059 90 90 Door 76 0.387 90 90 Door 76 0.387 90 9.0_ Wall 310 0.059 180 _9Q_ Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Total Fenestration Area: 24.3% Total Conditioned Volume: 51,356 ft 3 Total Conditioned Slab Area: 4,490 ft 2 # of Thermostat Vent Units Zone Type Type Hgt. Area —n2L Slee incl Sleeping$tat n/a _0�5_ Living l ivingS at n/a 0"10 Sleepang Slee incl at 2 n/a 0.15 Conditioned Setback 2 n/a Form 3 Reference Zone 1 Zone 1 Zone 1 Zone 1 Zone 3 Zone_3 Zone 3 Zone 3 Garage Garage .Garage Garage Garage Location / Comments I EnerklyPro 3.1 By EnernySoft User Number. 5862 Job Number. Paae:9 of 44 1 Computer Method Summary (Part 2 of 3) C -2R Nagy Residence 6/5/2004 Project Title Date 40 FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments J_ Window Right (North) 10.0_ -0-53D x,._43 n -90 F1eetwood_Glazing Zone 1 2 Window Right (North) 15.8 0.530 0.43 0 90 Fleetwood Glazing Zone 1 3 Window Right (North) 15.8 0.530 0.43 0 90 Fleetwood Glazing Zone 1 4 Window Front (East) 16.0 0.450 0.43 90 90 Fleetwood Glazing Zone 1 5 Window Front (East) 42.5 0.450 0.43 90 90 Fleetwood Glazing Zone 1 6 Window Front (East) 16.0 0.450 0.43 90 90 Fleetwood Glazing Zone 1 7 Window Front (East) 40.0 0.600 0.49 0 90 Fleetwood Glazing Zone 1 8 Window Left (South) 66.6 0.450 0.43 180 90 Fleetwood Glazing Zone 1 6 Window Left (South) 19.3 0.600 0.49 180 90 Fleetwood Glazing Zone 1 1Q Window Left (South) 10.0 0.530 0.43 180 90 Fleetwood Glazing Zone 1 Window Rear (West) 29.6 0.450 0.43 270 90 Fleetwood Glazing Zone 1 12 Window Right (North) 7.1 0.450 0.43 0 90 Fleetwood Glazing Zone 2 10 Window Right (North) 24.0 0,600 0.49 0 90 Fleetwood Glazing _Zone2 14 Window Right (North) 60.0 0.450 0.43 0 90 Fleetwood Glazing Zone 2 15 Window Front (East) 10.0 0.450 0.43 90 90 Fleetwood Glazing Zone 2 16 Window Front (East) 10.0 0.450 0.43 90 90 Fleetwood Glazing Zone 2 17 Window Front (East) 60.0 0.450 0.43 90 90 Fleetwood Glazing Zone 2 18 Window Front (East) 18.0 0.450 0.43 90 90 Fleetwood Glazing Zone 2 19 Window Front (East) 18.0 0.450 0.43 90 90 Fleetwood Glazing Zone 2 20 Window Front (East) 18.0 0.450 0.43 90 90 Fleetwood Glazing Zone 2 21 Window Front (East) 4.0 0.450 0.43 90 90 Fleetwood Glazing Zone 2 22 Window Front (East) 4.0 0.450 0.43 90 90 Fleetwood Glazing Zone 2 23 Window Front (East) 42.0 0.600 0.49 90 90 Fleetwood Glazing Zone 2 24 Window Front (East) 42.0 0.600 0.49 90 90 Fleetwood Glazing Zone 2 25 Window Front (East) 42.0 0.600 0.49 90 90 Fleetwood Glazing Zone 2 26 Window Front (East) 38.7 0.450 0.43 90 90 Fleetwood Glazing Zone 2 27 Window Front (East) 6.4 0.450 0.43 90 90 Fleetwood Glazing Zone 2 28 Window Front (East) 6.4 0.450 0.43 90 90 Fleetwood Glazing Zone 2 29 Window Rear (West) 7.1 0.530 0.43 270 90 Fleetwood Glazing Zone 2 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEM. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 _ 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen -dug 0.76 25 Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 X29 Bug Screen 0.76 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Paae:10 of 44 1 ' Computer Method Summary (Part 2 of 3) C -2R Nagy Residence 6/5/2004 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments .M W ndow Rear est) 240.0 0.600_ 0.49 X20_ _90 Fleetwood -Glazing Zone 2 31 Window Rear (West) 60.0 0.600 0.49 270 90 Fleetwood Glazing Zone 2 32 Window Rear (West) 10.0 0.450 0.43 270 90 Fleetwood Glazing Zone 2 33 Window Rear (West) 10.0 0.450 0.43 270 90 Fleetwood Glazing Zone 2 34 Window Left (South) 4.0 0.450 0.43 180 90 Fleetwood Glazing Zone 3 35 Window Left (South) 4.5 0.530 0.43 180 90 Fleetwood Glazing Zone 3 .X Window Left (South) 48.0 0.600 0.49 180 90 Fleetwood Glazing Zone 3 37 Window Left (South) 15.0 0.450 0.43 180 90 Fleetwood Glazing Garage WNTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 Run Initiation Time: 2:1 Code: EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page: 11 of 44 Computer Method Summary F2 Factor (Part 3 of 3) - C -2R Nagy Residence Slab Perimeter 5 0.76 6/5/2004 Project Title Slab Perimeter _6 0.76 Date WHERMAL MASS FOR HIGH MASS DESIGN Slab Perimeter 216 0.76 0.0 —0 Area Thick. Heat Slab Perimeter 27 Inside Location Type (sf (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, HeamMight 238. 4-00 28 -0-0 n/a 0 Zone 1 / Slab on Grade Concrete, Heavyweight 694 4_00 28 0_98 n/a 2 Zone 1 / Slab on Grade Concrete. Hea4 wei hg_t 1-467 4.00 --M 0.98 n/a 0 Zone 2 / Slab on Grade Masonry Veneer 75 2_00 25 0_62 R-21 Wall (W.21.24.16) 0 Zone 3 / Exterior Mass Masonry Veneer 356 2.00 75 0.62 R-21 Wall (W.21.24.16) 0 Zone 3 / Exterior Mass PERIMETER LOSSES Type Length F2 Factor Insulation R -Val. Depth Location / Comments Slab Perimeter 5 0.76 0.0 0 Zone 1 Slab Perimeter _6 0.76 0-0 _Q Zone 1 Slab Perimeter 216 0.76 0.0 —0 Zone 2 Slab Perimeter 27 0.76 0.0 _ 0 Zone 3 Slab Perimeter 32 0.76 0.0 0 Zone 3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 81%AFUE Duds in Attic 4.2 Setback Master Suite Central Furnace 81%AFUE Duds in Attic 4.2 Setback Living Area Central Furnace 80%AFUE Duds in Attic 4.2 Setback Guest Room 1 None n/a Ductless / with Fan n/a Setback Garage Hydronic Piping pipe Pipe Insul. •System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 14.9SEE B Duds in Attic 4.2 Setback Master Suite Split Air Conditioner 13.0 SEER Duds in Attic 4.2 Setback Living Area Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback Guest Room 1 Room PTAC without Side Louvers 9.8 EER Ductless n/a Setback Garage WATER HEATING SYSTEMS Rated' Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext A.O. SMITH FPS -75-230 Small Gas Recirc/Time+Temp 2 75,000 75 0.88 n/a n/a For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Part 3 of 3) C -2R Nagy Residence Minimum Distribution Type 6/5/2004 Project Title Type (furnace, heat Date •THERMAL MASS FOR HIGH MASS DESIGN Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, Area Thick. Heat R -Value Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete HeamMight 126 4^00 _2$_ -OM n/a 0 Zone 3 / Slah on Grafip Concrete. Heavyweight 302 4_00 28 0_98 n/a 2 Zone 3 / Slab on Grade Masonry Veneer 185 2M --25 0.62 R-21 Wall /.21.24.16) _0 Garage / Exterior Mass Masonry Veneer 310 2,00 25 0.62 R-21 Wall (V1L.21.24.16) 0 Garage / Exterior Mass Concrete Heavyweight 663 4.00 28 0.98 n/a 0 Garage / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 79 0.76 0.0 0 Garage HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Insul. Hydronic Piping pipe Pipe • System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated Input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Addendum) C -2R Nagy Residence 6/5/2004 Project Title Date .Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted.plate FiPd �J The HVAC System "Master Suite" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 238 sqft Exposed Slab Floor, 4.00" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 694 sqft Covered Slab Floor, 4.00" thick at Zone 1 The HVAC System "Living Area" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2467 sqft Exposed Slab Floor, 4.00" thick at Zone 2 The HVAC System "Guest Room 1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 75 sqft Masonry Veneer Exterior Mass, 2.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 356 sqft Masonry Veneer Exterior Mass, 2.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 126 sqft Exposed Slab Floor, 4.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 302 sqft Covered Slab Floor, 4.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 185 sqft Masonry Veneer Exterior Mass, 2.00" thick at Garage HIGH MASS Design(see C -2R) - Verify Thermal Mass: 310 sqft Masonry Veneer Exterior Mass, 2.00" thick at Garage HIGH MASS Design(see C -2R) - Verify Thermal Mass: 663 sqft Exposed Slab Floor, 4.00" thick at Garage HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Pian I Field The HVAC System "Master Suite" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Master Suite" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Living Area" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Living Area" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Forth. The HVAC System "Guest Room 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Guest Room 1" is using reduced dud leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Forth. The HVAC System "Garage" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Computer Method Summary (Addendum) C -2R Nagy Residence 6/5/2004 Project Title Date .Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies jasea on the aaequacy or tome special /usuncatnon ano oocumemauon suommea. Plan I Field HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF-SR.'Plan The to comply and must have * by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page: 15 of 44 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Nagy Residence 6/5/2004 SYSTEM NAME FLOOR AREA AN Master Suite 932 Number of Systems 1 Heating System Output per System 62,000 Total Output (Btuh) 62,000 Output (Btuh/sgft) 66.5 Cooling System Output per System 48,000 Total Output (Btuh) 48,000 Total Output (Tons) 4.0 Total Output (Btuh/sgft) 51.5 Total Output (sgft/Ton) 233.0 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfmisgft) 1.72 Airflow (cfmrron) 400.0 Outside Air (%) 14.4 Outside Air (cfm/sgft) 0.25 Note: values above given at ARI conditions 26.0 of 63.1OF Outside Air 230 cfm Supply Fan 1600 cfm 69.4 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM7Sensiblel Latent I CFM I Sensible 1,510 27,322 430 570 21,249 0 1,366 1,062 0 0 230 10,324 -130 230 10,617 0 0 1,3661 1,062 40,378 300 33,991 TRANE 4TTX48/TUD100R948 (4) 40,377 0 62,000 Total Adjusted System Outputao,377 0 62,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 63.10F 105.0 OF Heating Coil h Return Air Ducts `i Supply Air Ducts 104.4 of ROOMS 70.0 of 15.0 / 73.5 of 78.9 / 62.6 of 78.9 / 62.6 of. 55.0 / 53.7 of %. � -' S 1 A' D Outside Air 230 cfm 72.8/60.5 of Supply Fan Cooling Coil 1600 elm Return Air Ducts ' upp y Ir uCtS 55.8/54.0 of 50.7% R.H. R007M7S71 72.0 / 60.2 of EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page: 16 of 44 • IRVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Nagy Residence 6/5/2004 SYSTEM NAME FLOOR AREA Living Area 2.467 Number of Systems 2 Heating System Output per System 79,000 Total Output (Stuh) 158,000 Output (Btuh/sgft) 64.0 Cooling System Output per System 58,000 Total Output(Stuh) 116,000 Total Output (Tons) 9.7 Total Output (Btuh/sgft) 47.0 Total Output (sgftlron) 255.2 Air System CFM per System 2,000 Airflow (cfm) 4,000 Airflow (cfm/sgft) 1.62 Airflow (cfmrron) 413.8 Outside Air (%) 5.8 Outside Air (cfm/sgft) 0.09 Note: values above given at ARI conditions 26.0 of 310� Outside Air 230 cfm 69.4 of 15.0 / 73.5 of *---;1 Outside Air 230 cfm 72.9/60.6 of 3.1 PSYCHROMETRICS 66.9 of 66.9 of Supply Fan 4000 cfm Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 4,074 73,714 1,14 Ljj265 47,112 0 3,686 2,356 0 0 230 10,308 -189 230 10,634 0 0 3,6861 2,356 91,393 952 62,457 TRANE 4TTX4060rrUD100R960 (5) 89,869 5,965 158,000 Total Adjusted System Output 89,869 5,965 158,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am ,earn Temaeratures at Time of Heatina Peak) 105.0 of Heating Coil T k Return Air Ducts 4 75.3 / 61.4 of 75.3 /61.4 of 55.0 / 53.8 of 0 Supply Fan 4000 cfm Cooling Coil h Return Air Ducts "I User Number. 5862 Job Number. Supply Air Ducts 104.4 of ROOMS 70.0 of Supply Air Ducts 55.9/54.1 of 51.0% R.H. ROOMS 72.0 / 60.3 of 7 of 44 IRVAC SYSTEM HEATING AND COOLING LOADS SUMMARY 7 rNAME Nagy Residence NAME Guest Room 1 Number of Systems 1 Heating System Output per System 47,000 Total Output (Btuh) 47,000 Output (Stuh/sgft) 109.8 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 56.1 Total Output (sgftrTon) 214.0 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.87 Airflow (cfmfTon) 400.0 Outside Air (%) 28.8 Outside Air (cfm/sgft) 0.54 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/5/2004 FLOOR AREA 428 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 479 8,661 198 228 8,474 0 433 424 0 0 230 10,396 94 230 10,648 0 0 4331 424 19,923 292 19 969 TRANE 4TTX4024/TUD60R936 (2) 20,751 0 47,000 Total Adjusted System Output 20,75 0 x7,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 57.0 OF 57.0 OF 105.0 OF O Supply Air Ducts Outside Air 230 cfm Supply Fan Heating Coil 104.5 °F 800 cfm ROOMS 69.5 OF 70.0 °F i 15.0 / 73.5 OF >--71 Outside Air 230 cfm 72.5/60.1 °F h Return Air Ducts '4 84.7 / 64.3 OF 84.7 / 64.3 OF 55.0 / 53.3 OF 0 Supply Fan 800 cfm Cooling Coil k Return Air Ducts `i Supply Air Ducts 55.5/53.5°F 49.5% R.H. ROOMS 72.0 / 59.9 OF EneravPro 3.1 By EnerovSoft User Number. 5862 Job Number. Paae:18 of 44 1 114VAC SYSTEM HEATING AND COOLING LOADS SUMMARY rNAME Nagy Residence NAME Gara4e Number of Systems 1 Heating System Output per System 47,000 Total Output (Btuh) 47,000 Output (Btuh/sgft) 70.9 Cooling System Output per System 34,200 Total Output (Btuh) 34,200 Total Output (Tons) 2.8 Total Output (Btuh/sgft) 51.6 Total Output (sgftrron) 232.6 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.21 Airflow (cfm/Ton) 280.7 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above gi EATING SYSTEM 26.0 of Outside Air 0 cfm 69.2 of 15.0 / 73.5 OF )0—� Outside Air 0 cfm 72.7/60.6 of n at ARI conditions SYCHROMETRICS 69.2 of 69.2 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/5/2004 FLOOR AREA 663 COIL COOLING PEAK IOIL HTG. PEAK CFM Sensible Latent CFM I Sensible 694 12,553 306 354 13,179 0 628 659 0 0 0 0 0 0 0 0 0 628 659 13,808 306 14,497 E 2TTB0036/MCW536AMUAO 27,235 662 0 Total Adjusted System Output 27,235 662 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 105.0 of Supply Fan Heating Coil 800 cfm 72.7 / 60.6 of 72.7 / 60.6 OF k Return Air Ducts 4 watures at Time 55.0 / 53.8 of Supply Fan Cooling Coil 800 cfm h Return Air Ducts `i Supply Air Ducts 104.2 of ROOMS 70.0 of Supply Air Ducts 55.7/54.1OF 51.2% R.H. ROOMS 72.0 / 60.4 of EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:19of 44 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:20 of 44 ROOM LOAD SUMMARY PROJECT NAME Nagy Residence DATE 6/5/2004 SYSTEM NAME Master Suite FLOOR AREA 932 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 1 Zone 1 1 1,510 27,322 430 1,510 27,322 430 570 21,249 PAGE TOTAL 1 1,510 27,322 430 11 570 21,249 TOTAL 1 1,510 27,322 430 570 21,249 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:20 of 44 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:21 of 44 PROJECT NAME DATE Nagy Residence 6/5/2004 SYSTEM NAME FLOOR AREA Living Area 2,467 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:21 of 44 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 2 Zone 2 1 4,074 73,714 1,141 4,074 73,714 1,141 1,265 47,112 PAGE TOTAL 1 4,074 73,714 1,141 1,265 47,112 TOTAL 1 4,074 73,714 1,141 1,265 47,112 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:21 of 44 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page: 22 of 44 PROJECT NAME Nagy Residence DATE 6/5/2004 SYSTEM NAME Guest Room 1 FLOOR AREA 428 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 3 Zone 3 1 479 8,661 198 479 8,661 198 228 8,474 PAGE TOTAL 1 4791 8,6611 198 228 8,474 TOTAL 1 479 8,661 198 228 8,474 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page: 22 of 44 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:23 of 44 IROOM LOAD SUMMARY PROJECT NAME Nagy Residence DATE 6/5/2004 SYSTEM NAME Garage FLOOR AREA 663 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mull CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Garage Garage 1 694 12,553 306 694 12,553 306 354 13,179 PAGE TOTAL 1 694 12,553 306 354 13,179 TOTAL 1 694 12,553 306 354 13,179 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:23 of 44 ROOM HEATING PEAK LOADS r roject Title Date a Residence 6/5/2004 Room Information Desian Conditions Room Name Zone 1 Time of Peak Jan 12 am Floor Area 932 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr 932.0 X x X x x x x x x x x X X X x x X x X X X X X x X x X x X X X x x X X x x x x 0.0284 X X X X X X x x x x x X X X X x X x X X X X x x x x X X x X x x X X X X x X X 44.0 = = = = = = = = = = = = = = = = = 1,163 1,482.4 0.0592 44.0 3,862 51.6 0.5300 44.0 1,203 170.7 0.4500 44.0 3,381 59.3 0.6000 44.0 1.565 'meter = 112.0 44.5 4,984 Items shown with an asterisk (*)) denote conduction through an interior surface to another room. Page Total: 16 158 Infiltration: i1 1.001 x 1.064 x 932 x 14.00 x 0.50 / 60] x AT = 5 092 chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 21,249 Is EnergyPro 3.1 By EnergySott User Number. 5862 Job Number. Page: 24 of 44 • ROOM HEATING PEAK LOADS Project TIUe Date Na Residence 6/5/2004 Room Information Desi n Conditions Room Name Zone Time of Peak Jan 12 am Floor Area 2,467 Outdoor Dry Bulb Temperature 26 of Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr 2,467.0 X X X X x X x x X X x X X X X X X X X X X X X X X X X X X X X X X x X X x x X 0.0284 X X X X x X x x X X X X x x X X x x X X X x X x X X X x X X x X X X X X X X X 44.0 = = = = = = = = = = = = = = = = = = = = = 3,078 2,522.4 0.0592 44.0 6,571 280.5 0.4500 44.0 5,555 450.0 0.6000 44.0 11,880 24.0 0.5917 44.0 625 7.1 0.5300 44.0 164 perimeter = 216.0 44.5 9,612 Items shown with an asterisk (•)) denote conduction through an interior surface to another room. Page Total: 37 485 Infiltration: I1 1.001 x 1.064 x 2467 x 10.00 x 0.50 / 6 ] x ® = 9 627 chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 47,112 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page: 26 of 44 ROOM HEATING PEAK LOADS • Conduction Area U -Value AT of Btu/hr 428.0 X X X x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0284 X X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 44.0 = = = = = = = = = = = = = = = = a = = = = = = = = = = = = = = = = 534 681.5 0.0592 44.0 1,775 4.0 0.4500 44.0 79 4.5 0.5300 44.0 105 48.0 0.6000 44.0 1,267 perimeter = 59.0 44.5 2,626 Items shown with an asterisk (*)) denote conduction through an interior surface to another room. Page Total: 6 386 Infiltration: I1 1.001 x 1.064 x 428 x 12.50 x 0.50 / 6 ] x ® = 2 088 `schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 8,474 • EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page: 26 of 44 • ROOM HEATING PEAK LOADS Project Title Date Na Residence 16/5/2004 Room Information Desion Conditions Room Name Garage Time of Peak Jan 12 am Floor Area 663 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT OF Btu/hr 663.0 X x x x x X x x x x x X X x X X X X X x x X x x X X X x x X X x X X x X x x X 0.0284 X X x X x X x X X x x X X x X X X x X X X x x X x X X X x x X X X X X X x x x 44.0 = = = = = = = = = = = = = = = = = = = = 827 796.0 0.0592 44.0 2,074 24.0 0.5917 44.0 625 153.0 0.3872 44.0 2,607 15.0 0.4500 44.0 297 perimeter = 79.0 44.5 3,516 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 9945 Infiltration: Iool X 1.064 x 663 x 12.50 x 0.50 / 60] X ® = 3 234 chedule Air Sensible Area Ceiling Height ACH ILT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 13,179 • EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page: 27 of 44 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Nagy Residence 6/5/2004 Project Title Date Room Name Zone 1 Design Indoor Dry Bulb Temperature: 720F Design Outdoor Dry Bulb Temperature: 1160F Design Temperature Difference: 44°F Conduction .2x14.1 Area U -Value X DETD1 X 61.0 X 40.6 X 44.0 X 44.0 X 44.0 X X X X Btu/hr 1,612 3,563 1,203 3,381 1,565 1. Design Equivalent Temperature Difference (DEM) Page Total 11 324 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr 24 North 21 North 22 North 21 20 (East) (East) 19 O 18 (East) East South S South 26 South ( 0.0 X1 X x x X x x X X X + + + + + + + + + 10.0 x X x X x X X X X x 15 ) X )X X X X X X X x 0.479 = = = = = = = = = 72 ( 0.0 1 15.8 15 0.479 113 ( 0.0 1 15.8 15) 0.479 113 ( 0.0 1 16.0 73) 0.479 559 ( 0.0 1 42.5 73)x 0.479 1,485 ( 0.0 10+ 16.0 73) 0.479 559 ( 0.0 1 40.0 73) 0.545 1,593 ( 0.0 1 66.6 32) 0.479 1,020 ( 0.0 1 19.3 3) 0.545- 337 ( 0.0 1 10.0 32) 0.479 153 Sched. Page Total s o05 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 932 x 0.500 Watts/sgft X 3.413 Btuh/Watt = 1,590 Occupants 1.00 X 932 X 245 Btuh/OCC. / 333 sgft/occ. = 685 Receptacle 1.00 x 932 X 0.500 Watts/sgft X 3.413 Btuh/Watt = 1,590 Process 1.00 x 932 x 0.000 Watts/sgft x 3-413 Btuh/Watt = 0 Infiltration: x Airx Sensible � 60] X �IIIn 14.00 x / = 5 92 g Height ACH Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 27,322 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occu ants 1.00 x 932 x 155 Btuh/OCC. / 33 sgft/OCc. = 433 Receptacle 1.00 x 932 x 0.000 Watts/sgft X 3.41 Btuh/Watt = o Process 1.00 X 932 x 0.000 Watts/sgft X 3.41 Btuh/Watt = 0 Infiltration: I ool X L 477 X 93 X 14.00 x 0.50 / 60] -0.00001 = 0 chedule Air Latent Area Ceiling Height ACH &W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 430 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:28 of 44 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Nagy Residence 6/5/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value DETD' Zone 1 72°F 116°F 440E 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 25 (West) ( 0.0 x 1 + 29.6 X 73) x 0.479 = 1,036 ( x + x )x = ( x + x )x = ( x + x )X ( x + x )x = ( x + x )X ( x + x )x = ( x + x )x = ( x + x )X = Al11 x + x )x = Sched. Page Total 1 036 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 X 932 X 0.500 Watts/sqft x 3.413 Btuh/Waft = 1,590 Occupants 1.00 X 932 X 245 Btuh/occ. / 333 sgft/occ. — 685 Receptacle 1.00 x 932 X 0.500 Watts/sgft x 3.413 BtuhMatt = 1,590 Process 1.00 x 932 x 0.000 Watts/sgft x 3-412 Btuh/Watt = 0 Infiltration: X Air sensible X Area X Ceiling � X ACH 60] Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 27,322 Sched. Latent Gain Frac. Area Heat Gain Btulhr Occupants 1.00 x 932 x 155 Btuh/OCC. / 33 sgft/OCC. = 433 Receptacle 1.00 X 932 x 0.000 Watts/sgft X 3.41 Btuh/Watt = 0 Process 1.00 x 932 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: 1 1.001 X Air �� X Area Ceiling x Ceiling Height x ACH 50 / 60] ow o001 = 0 SFraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 430 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:29 of 44 • • • " RESIDENTIAL ROOM COOLING LOAD SUMMARY Nagy Residence 6/5/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Zone 2 720F 116°F 44°F Conduction Area U -Value DETD 1 Btu/hr x x X X X X 61.0 = = = = = = 4,267 40.6 6,064 44.0 5,555 44.0 11,880 40.6 577 44.0 164 X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 28 506 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btulhr 3 (North) + 1 + 1 + 1 + 1 + 1 + 1 + 1 + Al + (North) 14 17 North East 16 15 (East) (East) 13 (East) 12 East 11 (East) 33 East ( 0.0 X1 X x x X x x73) x x X + 1 + 1 + 1 + 1 + 1 + 1 + 1 + Al + 7.1 X X X X X X x X x 15 ) X ) X X x x X X X x 0.479 = = = = = = = = _ = 51 ( 0.0 24.0 15 0.545 196 ( 0.0 60.0 15) 0.479 431 ( 0.0 10.0 73) 0.479 349 ( 0.0 10.0 73) 0.479 349 ( 0.0 60.0 73) 0.479 2,097 ( 0.0 0.479 629 ( 0.0 18.0 73) 0.479 629 ( 0.0 18.0 73)x 0.479 629 ( 0.0 4.0 73) 1 0.47 140 Sched. Page Total 5 500 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 X 2,467 X 0.500 Watts/sgft x 3.41 Btuh/Watt = 4,210 Occupants 1.00 X 2,467 X . 245 Btuh/occ. / 333 sgft/occ. = 1,813 Receptacle 1.00 x 2,46 X 0.500 Watts/sgft X 3.413 Btuh/Waft = 4,210 Process 1.00 X 2,467 X 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: xAirS� x Area x Ceiling � x ACH / 60] zn�T = 627 Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 73,7141 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 2467 X 155 Btuh/OCC. / 33 sgftlocc. = 1 47 Receptacle 1.00 x 2467 x 0.000 Watts/sgft X 3.41 Btuh/Watt = 0 Process 1.00 x 2467 X 0.000 Watts/sgft X 3.41 Btuh/Watt = 0 Infiltration: I tool x L 477 X 246 x 10.00 x 0.50 / 60] -0.00001 = 0 chedule Air Latent Area Ceiling Height ACH OW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,1411 EnergyPro 3.1 By EnergySott User Number. 5862 Job Number. Page: 30 of 44 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Nagy Residence 6/5/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X DETD1 Zone 2 72°F 116°F 440E Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 32 East 1 + 1 + 1 + 1 + 1 +. 1 + 1 + 1 + 1 + 1 + (East) N East M (East) 10 9 (East) (East) 8 East 4 est D (West) C est ( 0.0 X X x x x x x x X x 1 + 1 + 1 + 1 + 1 +. 1 + 1 + 1 + 1 + 1 + 4.0 X X X x X x x X x x 73 ) X ) X X x X x X 0.479 = = = = = = = = = 140 ( 0.0 42.0 73 0.545 1,672 ( 0.0 42.0 73) 0.545 1,672 ( 0.0 42.0 73)x 0.545 1,672 (-0.0 38.7 73)x 0.479 1,352 ( 0.0 6.4 73) 0.479 224 ( 0.0 6.4 73) 0.479 224 ( 0.0 7.1 73) 0.479 0.0 240.0 7) 0.54rE�0.0 A389 60.0 73)x 0.545 Sched. Page Total 1 19.14 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 2,467 x 0.500 Watts/sgft x 3.41 Btuh/Watt = 4,210 Occupants 1.00 X 2,467 X 245 Btuh/occ. / 333 sgft/occ. = 1,813 Receptacle 1.00 x 2,467 x 0.500 Watts/sgft x 3.413 Btuh/Watt = 4,210 Process 1.00 x 2,4677xx 0.000 Watts/sgft x 3-413 Btuh/Watt = 0 Infiltration: x Air Sensible x Area 2:467 x Ceiling � x CHACH / 60] � Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 73,7141 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 2467 X 155 Btuh/occ. / 33 sgft/occ. = 1 147 Receptacle 1.00 x 2467 X 0.000 Watts/sgft x 3.41 Btuh/Watt = o Process 1.00 x 2467 x 0.000 Watts/sgft X 3.41 Btuh/Watt = 0 Infiltration: I 1.00 x 477 x 2 46 x 10.00 x 0.50 / 60] -0.00001 = chedule Air Latent Area Ceiling Height ACH �yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 141 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:31 of 44 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Nagy Residence 6/5/2004 Projed Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area X U -Value DETD' Zone 2 720F 116°F 44°F Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 1 Meso (' 0.0 X 1 + 10.0 x 73 ) X 0.479 = 349 (West) ( 0.0 X 1 + 10.0 X 73)X 0.479 = 349 ( X + X )X = ( x + X )x ( X + x )x ( X + X )x = ( x + X )X = ( x + x )x = ( X + x )X = ( X + X )X Sched. Page Total s99 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 X 2,467 x 0.500 Watts/sgft X 3.41 Btuh/Watt = 4,210 Occupants 1.00 X 2.46 X 245 Btuh/occ. / 333 sgft/occ. = 1,813 Receptacle 1.00 x 2,467 x 0.500 Watts/sgft X 3.413 Btuh/Watt = 4,210 Process 1.00 x 2,467 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: �c x Air Sensible x Area x Ceiling � x ACH / 60] � Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 73,714 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 2467 x 155 Btuh/OCC. / 333 sgft/OCc. = 1 147 Receptacle 1.00 x 2467 x 0.000 Watts/sgft X 3.41 BtuhMatt = o Process 1.00 X 2 467 X 0.000 Watts/sgft X 3.41 Btuh/Watt = 0 Infiltration: �cnetool x E 4.77 Air Latent X Area x Ceiling Height x ACH 50 / 60] o0�0i 0001 = 0 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,1411 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page: 32 of 44 RESIDENTIAL ROOM COOLING LOAD SUMMARY Nagy/ Residence 6/5/2004 Project Title Date • Room Name U r1 �J Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Area U -Value X Zone 3 72°F 116°F 440E X X X X X DETD 1 = = = = = Btu/hr 61.0 740 40.6 1,638 44.0 79 44.0 105 44.0 1.267 1. Design Equivalent Temperature Difference (DETD) Page Total 3 830 Items shown with an asterisk (•) denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 7 South ( 0.0 X 1 + 4.0 x 32 ) X 0.479 = 61 (South) ( 0.0 X 1 + 4.5 X 32 )x 0.479 = 69 J South ( 0.0 X 1 + 48.0 x 32 ) X 0.545 = 838 ( x + X )x ( x + x )x = ( x + X )x ( x + x )x = ( x + x )x = ( x + x )X = ( x + I x I )x I= Sched. Page Total 9s8 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 428 x 0.500 Watts/sgft X 3.41 Btuh/Watt = 730 Occupants 1.00 x 428 X 245 Btuh/occ. / 333 sgft/occ. = 315 Receptacle 1.00 x 428 x 0.500 Watts/sqft x 3.413 Btuh/Watt = 730 Process 1.00 x 428 X 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: �c� x Air Sensible x Area X Ceiling � x ACH / 60] Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,6611 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 428 x 155 Btuh/OCC. / 33 sgft/occ. = 199 Receptacle 1.00 x 428 x 0.000 Watts/sgft x 3.41 BtuhMaft = 0 Process 1.00 X 428 x 0.000 Watts/sgft x 3.41 Btuh/Waft = 0 Infiltration: ched le x Air Latent x Area42 x Ceiling Height x ACH'5o / 60] Q0�0�0001 = 01 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 198 EnergyPro 3.1 By Energ Soft User Number. 5862 Job Number. Page:33 of 44 • n U • RESIDENTIAL ROOM COOLING LOAD SUMMARY Nagy Residence 6/5/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Garage 720F 116°F 440E Conduction Area U -Value DETD' Btu/hr X 61.0 = 1,147 X 40.6 = 1,913 X 40.6 = 577 X 40.6 = 2,405 X 44.0 = 297 X X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 6 339 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 5 (South) ( 0.0 X 1 + 15.0 X 32) X 0.479 = 230 ( x + x )x ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x -) x = ( x + x )x = ( x + x )x = ( x + x )x = Sched. Page Total 230 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 663 X 0.500 Watts/sgft x 3.413 Btuh/Watt = 1,131 Occupants 1.00 X 663 X 245 Btuh/OCc. / 333 sgft/OCc. = 487 Receptacle 1.00 x 663 x 0.500 Watts/sqft x 3.413 Btuh/Watt = 1,131 Process 1.00 X 663 x 0.000 Watts/sqft X 3.41 Btuh/Watt = 00 Infiltration: �� x � x � x x � / 60] z = t_3,234J Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 1Z5531 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occu ants1.00 x 663 x 155 Btuh/OCc. / 33 sgft/OCc. = 308 Receptacle 1.00 X 663 x 0.000 Watts/sqft X 3.41 BtuhMatt = o Process 1.00 X 663 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Infiltration: 1 1. ol X L 477 X 66 X 12.50 X 0.50 / 60] -0.00001 = 0 chedule Air Latent Area Ceiling Height ACH DW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 306 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:34 of 44 TITLE 24 REPORT I Title 24 Report for: Nagy Residence -Guest House 53-717 Via Palacio - The Hideaway La Quinta, CA 92253 Project Designer: Kristi Hanson Architects, Inc. 72-185 Painters Path Suite #A Palm Desert, CA 92260 760-776-4068 Report Prepared By: Gina Rose G.R. Rose CAD Design 42335 Washington Suite F #330 Palm Desert, CA 92211 (760) 345-4859 Job Number: Date: 6/5/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EneravPro 3.1 By EneraySoft Job Number. User Number. 5862 1 • • • Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Nagy Residence -Guest House 6/5/2004 Project Title Date 53-717 Via Palacio - The Hideaway La Quinta Project Address Building Permit # G.R. Rose CAD Design (760) 345-4859 Plan Check I Date Documentation Author Telephone Computer Performance 15 Field Check I Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 655 ft2 Total Conditioned Slab Area: 655 ft2 Average Ceiling Height: 12.5 ft Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (.West) 270 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor FENESTRATION Location/Comments (attic, garage, typical, etc. Exterior Roof Exterior Wall Exposed Slab w/R-0.0 Perimeter Insulation Covered Slab w/R-0.0 Perimeter Insulation Shading Devices Type Orientation Const. Component Frame Assembly Type Type U -Value R-38 Roof (R.38.2x14.16) Wood 0.028 R-21 Wall (W.21.2x6.16) Wood 0.059 Slab On Grade n/a 0.756 Slab On Grade n/a 0.756 FENESTRATION Location/Comments (attic, garage, typical, etc. Exterior Roof Exterior Wall Exposed Slab w/R-0.0 Perimeter Insulation Covered Slab w/R-0.0 Perimeter Insulation Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Rear (East) 70.0 0.60 0.49 Bug Screen ❑ X❑ ❑ X❑ Rear (East) 37.0 0.53 0.43 Bug Screen ❑ X❑ ❑X❑ Front (West) 18.0 0.45 0.43 Bug Screen ❑ X❑ ❑ X❑ Front (West) 17.6 0.53 0.43 Bug Screen ❑ X❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El F-1 El F1 ❑❑ El F1 El El ❑❑- ❑❑ n ❑ ❑ ❑ ❑ Run Initiation Time: 0610510414:4 :51 Run Code: 1086 7201 Ener Pro 3.1 By EnergySoft User Number. 5862 Job Number. Pa e:3 of 25 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Nagy Residence -Guest House 6/5/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronlc data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments [:antral FumanA 80% AFUE Ducts in Attic 4.2 Setback Guest House Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 4 2 Sethark Guest I -muse WATER HEATING SYSTEMS Rated 1 Tank Energy Fact. 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A _ SMITH FPS -50-224 Small Gas RecircMma+Temp 1 43-000 so 0.60 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated Input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Gina Rose Title/Firm: Kristi Hanson Architects, Inc. Title/Firm: G.R. Rose CAD Design Address: 72-185 Painters Path Suite #A Address: 42335 Washington Suite F #330 Palm Desert, CA 92260 Palm Desert, CA 92211 Telephone: 760-776-4068 Telephone: (760) 345-4859 (signature) (date) signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: • (signature/stamp) (date) Run Initiation Time: 06/05/0414:46:51 Run Coda: 1086472011 Certificate of Compliance: Residential (Addendum) CF -1 R Nagy Residence -Guest House 6/5/2004 Project Title Date Thpecial Features and Modeling Assumptions e local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )asea on me aaequacy oT me special tustmcauon and documentation suomntea. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 460 sgft Exposed Slab Floor, 4.00" thick at Zone 1 I HIGH MASS Design(see C -2R) - Verity Thermal Mass: 195 sgft Covered Slab Floor, 4.00" thick at Zone 1 HERS Required Verification These features must be confirmed andfor tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -51R. Plan Field The HVAC System "Guest House" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verififiication of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Guest House" is using reduced duct leakage to comply and must have diagnostic site testing of dud leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. 1 EnerwPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:5 of 25 1 .7 • • Mandatory Measures Checklist: Residential (Page 1 of 2) MF -IR NOTE: Lowdse residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures a '§150(a): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturer's labeled R -Value. "§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does 0 not apply to exterior mass walls). "§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. Slab edge Insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑§150(1): greater than 2.0 perm/inch. © §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(9: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures § 110.13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. © §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA. a§150(1): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Baric -up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemallextemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:6 of 26 0 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or Initial applicable boxes or enter NIA If not applicable. DESIGNER JENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) FX]`§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181. UL181A, or UL1818. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of dud systems and their components shall not be sealed with doth back rubber adhesive dud tapes unless such tape Is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, dud board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain duds. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with doth back rubber adhesive dud tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot 2. System is installed with at least 36" of pipe between fitter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. r IA -11 §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specked criteria Lighting Measures ❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ❑ §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number. 5862 Job Number. Page:7 of 25 Computer Method Summary (Part 1 of 3) C-2R _N avRtsirience-Guest House ProjiTC1 Title 6/5/2004 Date roject Address Building Permit # Q_R_ Rose CAD Design (760) 345-4859 Documentation Author Telephone Plan Check/Date Computer Performance Compliance Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 4.93 3.11 1.82 Space Cooling 58.43 60.52 -2.09 Domestic Hot Water 29.84 24.58 5.26 Totals 93.20 88.21 4.99 Percent better than Standard: 5.4% Total Conditioned Floor Area: 655 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Type: Single Fam Detached Building Front Orientation: (West) 270 deg Total Fenestration Area: 21.8% Number of Dwelling Units: 1.00 Total Conditioned Volume: 8,188 ft s Number of Stories: 1 Total Conditioned Slab Area: 655 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area Guest Hnuse 65 81$$ 1 nn Cnnditinned sethark n1a •OPAQUE SURFACES Saiar Act. Gains Type Area U -Fac. Azm. Tilt Y / N Form 3 Reference Location / Comments Computer Method Summary (Part 2 of 3) C -2R Nagy Residence -Guest House 6/5/2004 Project Title Date SURFACES FENESTRATION U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 4 win Bear (Easfl _0.ML 0.49 90 90 Fleetwood Glazing Zone 1 2 Window Rear (East) 37.0 0.530 0.43 90 90 Fleetwood Glazing Zone 1 3 Window Front (West) 18.0 0.450 0.43 270 90 Fleetwood Glazing Zone 1 4 Window Front (West) 8.8 0.530 0.43 270 90 Fleetwood Glazing Zone 1 5 Window Front (West) 8.8 0.530 0.43 270 90 Fleetwood Glazing Zone 1 •INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 I EnerovPro 3.1 By EnerovSoft User Number. 5862 Job Number: Page:9 of 25 1 Computer Method Summary (Part 3 of 3) C -2R Nagy Residence -Guest House 6/5/2004 Project Title Date WHERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete Heavyweight 460 -4M fig. 0.9g n/a _a Zone 1 /Slab on Grade Concrete. Heavyweight 195 4_00 28 0_98 n/a 2 Zone 1 / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 79 0.76 0.0 0 Zone 1 Slab Perimeter 35 0.76 0.0 0 Zone 1 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPFxducts/attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Guest House Hydronic Piping pipe Pipe Insul. Ah System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments ,Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback Guest House WATER HEATING SYSTEMS Ratedl Tank Energy Fact' 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.O. SMITH FPS -50-224 Small Gas Recirci7ime+Temp 1 43,000 50 0.60 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Addendum) C -2R Nagy Residence -Guest House 6/5/2004 Project Title Date �pecial Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies :iasea on the adequacy or the special justmcation and documentation suomittea. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 460 sqft Exposed Slab Floor, 4.00" thick at Zone 1 I HIGH MASS Design(see C -2R) - Verify Thermal Mass: 195 sgft Covered Slab Floor, 4.00" thick at Zone 1 1 1 1 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "Guest House" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Guest House" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. I EnerayPro 3.1 By EnergySoft User Number. 5862 Job Number. Page:11 of 25 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY rNAME Nagy Residence -Guest House NAME Guest House Number of Systems 1 Heating System Output per System 51,000 Total Output (Btuh) 51,000 Output (Btuh/sgft) 77.9 Cooling System Output per System 36,000 Total Output (Btuh) 36,000 Total Output (Tons) 3.0 Total Output (Btuh/sgft) 55.0 Total Output (sgfUTon) 218.3 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sgft) 1.83 Airflow (cfm/Ton) 400.0 Outside Air (%) 9.6 Outside Air (cfm/sgft) 0.18 Note: values above given at ARI conditions 26.0 of 65.2 of Outside Air 115 cfm Supply Fan 1200 cfm 69.4 of SYSTEM 115.0 / 73.5 of 0 Outside 115 cfm 72.7/60.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 6/5/2004 FLOOR AREA 655 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,044 18,884 303 426 15,854 0 944 793 0 0 115 5,170 -86 115 5,309 0 0 944 793 25,942 217 22 748 TRANE 4TTX4036/TUD100R936 (3) 29,181 791 51,000 Total Adjusted System Output 29,181 791 51,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 65.2 of =I 105.0 of Heating Coil h Return Air Ducts `i 76.8/61.9OF 76.8/61.9OF M 55.0/53.7OF -Ip Supply Fan 1200 cfm Cooling Coil k Return Air Ducts 'I Supply Air Ducts 104.4 of ROOMS 70.0 of Supply Air Ducts 55.7 154.0 OF 50.9% R.H. ROOMS 72.0 / 60.3 of EneravPro 3.1 By Eneray8oft User Number. 5862 Job Number. Page: 12 of 25 1 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page: 13 of 25 PROJECT NAME Nagy Residence -Guest House DATE 6/5/2004 SYSTEM NAME Guest House FLOOR AREA 655 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 1 Zone 1 1 1,044 18,884 303 1,044 18,884 303 426 15,854 PAGE TOTAL 1 1,044 18,884 303 426 15,854 TOTAL 1 1,044 18,884 303 426 15,854 EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page: 13 of 25 • ROOM HEATING PEAK LOADS Project Title Date Nagy -Residence -Guest House 6/5/2004 oom Information Desian Conditions Room Name Zone 1 Time of Peak Jan 12 am Floor Area 655 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr 655.0 x X X X X X x x X X x X x X X X X X X X X X X x X X X X X X X X X x x x x x x 0.0284 x X X X X X x X X X X X X X X X X X X X X X X x X X X X X X X X X x x x x x x 44.0 = = = = = = = = = = = = = = = = = = = = = = 817 1,263.4 0.0592 44.0 3,291 70.0 0.6000 44.0 1,848 54.6 0.5300 44.0 1,273 18.0 0.4500 44.0 356 perimeter= 114.0 44.5 5,073 Items shown with an asterisk (•) denote conduction through an interior surface to another room. Page Total: 12 659 Infiltration: 1 .001 X 1.064 x 655 X 12.50 X 0.50 / 60] X ® = 3195 `Schedule Air Sensible Area Ceiling Height ACH ILT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 15,854 • EnergyPro 3.1 By EnergySoft User Number. 5862 Job Number. Page: 14 of 25 • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Nagar Residence -Guest House 6/5/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X Zone 1 72°F 116°F 44°F X x X X X DETD 1 = = = = = Btu/hr 61.0 1,133 40.6 3,037 44.0 1,848 44.0 1,273 44.0 356 1. Design Equivalent Temperature Difference (DETD) Page Total 7648 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr T (East) ( 0.0 X1 + 70.0 X 73 ) X 0.545 = 2,787 27 East ( 0.0 x 1 + 37.0 X 73 )X 0.479 = 1,293 30 est ( 0.0 X 1 + 18.0 x 73) X 0.479 = 629 29 (West) ( 0.0 X 1 + 8.8 X 73)x 0.479 = 308 28 (West) ( 0.0 X 1 + 8.8 x 73)x 0.479 = 308 ( x + x )x = ( x + x )x = ( x + x )x = ( X + X )X Sched. Page Total 5,324 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 655 X 0.500 Watts/sgft x 3.4d Btuh/Watt = 1,118 Occupants 1.00 X 655 X 245 Btuh/OCC. / 333 sgft/occ. = 481 Receptacle 1.00 x 655 X 0.500 Watts/sgft x 3.413 Btuh/Watt = 1,118 Process 1.00 x 655 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: �c� xAirs x 655 x Area Ceiling x � / 60] Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,8841 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 655 x 155 Btuh/occ. / 333 sgft/occ. = 305 Receptacle 1.00 X 655 X 0.000 Watts/sgft X 3.41 Btuh/Watt = o Process 1.00 X 655 x 0.000 Watts/sgft X 3.41 Btuh/Watt = 0 Infiltration: ched le x Air Latent x Area65 X Ceiling Height x ACH 50 / 60] Qow 001 = 0 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 303 Energ Pro 3.1 By EnergySoft User Number. 5862 Job Number. Page: 15 of 25 Project Name Date ��� Equipment Number Sales Office/Distributor • TAG: • • Upflow > Horizontal Gas Furnace" Fan -Assisted Combustion" TUD060C924K 4° DIAMETER FLUE CONNI_CT 7/8"'DIA. K.O. ELECTRICAL CONNECTION 40„ (ALTERNATE) 1-1)2° DIA. K.O. GAS CONNECTION (ALTERNATE) \ I 5-5/16" 1.1/2° DIA. HOLE GAS CONNECTION 2-1/8" FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 TUD060C924K 4 - HIGH - Black 1013 997 973 941 901 852 796 731 659 3 - MED. -HIGH - Blue 835 821 800 771 734 689 636 575 506 2 - MED. -LOW - Yellow 712 702 683 655 617 571 516 452 379 1 - LOW -Red 611 596 1 573 1 543 505 459 1 406 345 277 CFM VS. TEMPERATURE RISE MODEL CFM (CUBIC FEET PER MINUTE) 700 1 800 1 900 1 1000 TUD060C924K 63 1 56 1 49 4'4 © American Standard Inc. 2002 • General Data o TYPE U flow / Horizontal RATINGS s Input BTUH 60,000 Capacity BTUH (ICS) 0 47,000 AFUE 80.0 Temp. rise (Min. -Max.) °F. 35-65 BLOWER DRIVE DIRECT Diameter -Width (In.) 10 x 6 No. Used 1 Speeds (No.) 4 CFM vs. in. w.g. See Fan PeHoirr ance Motor HP 1/5 R.P.M. 1080 Volts/Ph/Hz 115/1/60 COMBUSTION FAN - Type Centrifugal Drive - No. Speeds Direct - 1 Motor HP - RPM 1150-3000 VORs/Ph/HZ 115/1/60 F.L. Amps 1.0 FILTER — Furnished? No Type Recommended High Velocity Hi Vel. (No.-Size-Thk.) Shipped 1 -17x25 -1 in. VENT COLLAR —Size (in.) 4 Round HEAT EXC A GER Type -Fired Alum. Steel -Unfired Gauge (Fired) 20 ORIFICES — Main Nat.Gas. Qty. — Drill Size 3-45 L.P. Gas Qty. — Drill Size 3-56 GAS VALVE Redundant - Single Stage PILOT SAFETY DEVICE TYph Hot Surface I nition BURNERS — Type Muitipod Inshot Number 3 POWER CONN. —V/Ph/Hz 4 115/1/60 Ampacity (In Amps) 10.4 Max. Overcurrent Protection (amps) 15 PIPE CONN. SIZE (IN.) 1/2 DIMENSIONS H x W x D Crated (In.) 41- 3/4 x 16-1/2 x 30.1/2 Unrated (In.) 40 x 14-1/2 x 28 WEIGHT Shipping (Lbs.) / Net (lbs) 124/115 0 Central Furnace heating designs are certified by the American Gas Association lnc. Laboratories, O Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% for each 1000 feet above sea level. O Based on U.S. Government Standard Tests. O The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. Mechanical Specifications NATURAL GAS MODELS—Central heat- ing furnace designs are certified by the American Gas Association for both natu- ral and L.P. gas. Limit setting and rating data were established and approved un- der standardrating conditions using Ameri- can National Standards Institute standards. SAFE OPERATION — The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combi- nation gas valve and regulator provide extra safety. QUICK HEATING— Durable, cycle tested, heavy gauge aluminized steel heat ex- changer quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside, allows com- mon venting with hot water heater. Technical Literature - Printed in U.S.A. American Standard Inc. The Trane Company 6200 Troup Highway Tyler, TX 75707 BURNERS — Multi -port, in -shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners. INTEGRATED SYSTEM CONTROL— Ex- clusively designed operational program pro- vides total control of furnace limit sensors, blowers, gas valve, flame control and in- cludes self diagnostics for ease of service. AIR DELIVERY—The multispeed, direct - drive blower motor, with sufficient airflow range for most heating and cooling re- quirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. (Fan relay and 35VA control transformer is stan- dard). STYLING — Heavy gauge steel and "wraparound" cabinet construction is used in the cabinet with baked -on enamel finish for strength and beauty. The heat exchanger section of the cabinet is com- pletely lined with foil -faced fiberglass insu- lation. This results in quiet 'and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. FEATURES AND GENERAL OPERA- TION — These High Efficiency Gas Fur- naces employ a Hot Surface Ignition sys- tem, which eliminates the waste of a con- stantly burning pilot. The integrated sys- tem control lights the main burners upon a demand for heat from the room thermo- stat. Complete front service access. a. Low energy power venter. b. Vent proving differential switch. Since the Trane Company has a policy of continuous product improvement, it reserves the right to change specifications and design without notice. • • Project Name Equipment Number Sales Office/Distributor Date SUBMITTAL Upflow/ Horizontal Gas Furnace" Fan -Assisted Combustion" TUD10OC936K 4' DIAMETER FLUE CONNECT 7/8' DIA. K.O. - ELECTRICAL CONNECTION (ALTERNATE) 1-1/2' DIA. K.O. GAS CONNECTION (ALTERNATE) FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. \ I 5-5/16" SPEED TAP 0.10 0.20 0.30 0.40 1-1/2° DIA. HOLE 0.60 0.70 GAS CONNECTION 2-1/8" TUD10OC936K FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 TUD10OC936K 4 - HIGH - Black 1476 1464 1441 1408 1363 1307 1241 1163 1074 3 - MED. -HIGH - Blue 1249 1257 1252 1234 1203 1158 1101 1030 946 2 - MED. -LOW - Yellow 1020 1046 1058 1050 1028 990 936 866 780 1 - LOW - Red 873 887 890 883 864 834 794 742 680 ©American Standard Inc. 2002 CFM VS. TEMPERATURE RISE CFM CUBIC FEET PER MINUTE MODEL 1100 1200 1300 1400 1500 TUD10OC936K 67 1 62 1 57 53 f 49 ©American Standard Inc. 2002 PA • 11 General Data o TYPE U flow / Horizontal RATINGS Input BTUH 100,000 Capacity STUN (ICS) O 79,000 AFUE 80.0 Temp. rise (Min. -Max.) IF. 40- 70 BLOWER DRIVE DIRECT Diameter -Width (In.) 10 x 7 No. Used 1 Speeds (No.) 4 CFM vs. in. w.g. See Fan Performance Motor HP 1/3 R.P.M. 1075 Volts/Ph/Hz 115/1/60 COMBUSTION FAN - Type Centrifugal Drive - No: Speeds Direct - 1 Motor HP - RPM 1/50-3000 Volts/Ph/Hz 115/1/60 F.L. Amps 1.0 FILTER — Furnished.) Yes Type Recommended High Velocity Hi Vel. (No.-Size-Thk.) Shipped 1 -17x25 -1 in. VENT COLLAR — Size (in.) 4 Round HEAT EXCHANGER Type -Fired Alum. Steel -Unfired Gauge (Fired) 20 ORIFICES — Main Nat.Gas. Qty. — Drill Size 5-45 L.P. Gas City. — Drill Size 5-56 GAS VALVE Redundant - Single Stage PILOT SAFETY DEVICE Type Hot Surface Ignition BURNERS = Type Mulbport Inshot Number 5 POWER CONN. — V/Ph/Hz 115/1/60 Ampacity (In Amps) 10.4 Max. Overcurrent Protection (amps) 15 PIPE CONN. SIZE (IN.) 1/2 DIMENSIONS H x W x D Crated (In.) 41- 314 x 19-1/2 x 30-1/2 Uncrated_(In.).____ _ _. _ . _ _ . _ .__ . 40 x_1.771/2_x.28. _... _ .. -------- ______WEIGHT WEIGHT Shipping (Lbs.) / Net (Lbs) 151/141 O Central Furnace heating designs are certified by the American Gas Association Inc. Laboratories. ® Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet', Ratings should be reduced at the rate of 4% for each 1000 feet above sea level. O Based on U.S. Government Standard Tests. O The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. Mechanical Specifications NATURALGAS MODELS—Central heat- ing furnace designs are certified by the American Gas Association for both natu- ral and L.P. gas. Limit setting and rating data were established and approved un- der standard rating conditions using Ameri- can National Standards Institute standards. SAFE OPERATION — The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combi- nation gas valve and regulator provide extra safety. QUICK HEATING— Durable, cycle tested, heavy gauge aluminized steel heat ex- changer quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside, allows com- mon venting with hot water heater. Technical Literature - Printed in U.S.A. American Standard Inc. The Trane Company 6200 Troup Highway Tyler, TX 75707 BURNERS — Multi -port, in -shot burners will give years of quiet and efficient service. All models can be converted to L:P: gas without changing burners. INTEGRATED SYSTEM CONTROL— Ex- clusively designed operational program pro- vides total control of furnace limit sensors, blowers, gas valve, flame control and in- cludes self diagnostics for ease of service. AIR DELIVERY—The multispeed, direct - drive blower motor, with sufficient airflow range for most heating and cooling re- quirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate fumace operation when the blower door is removed. (Fan relay and 35VA control transformer is stan- dard). STYLING — Heavy gauge steel and "wraparound" cabinet construction is used in the cabinet with baked -on enamel finish for strength and beauty. The heat exchanger section of the cabinet is com- pletely lined with foil -faced fiberglass insu- lation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. FEATURES AND GENERAL OPERA- TION — These High Efficiency Gas Fur- naces employ a Hot Surface Ignition sys- tem, which eliminates the waste of a con- stantly burning pilot. The integrated sys- tem control lights the main burners upon a demand for heat from the room thermo- stat. Complete front service access. a. Low energy power venter. b. Vent proving differential switch. Since the Trane Company has a policy of continuous product improvement, it reserves the right to change specifications and design without notice. 0 TAG: C J Project Name Equipment Number Sales Office/Distributor 21 19-314-- 5/8"� 18-5/8" 28 3/ 5/8" 1/2 Date Upflow/ Horizontal Gas Furnace" Fan -Assisted Combustion" TUD10OR948K I FLUE CONNECT 4° DIAMETER 7/8° DIA. HOLES ELECTRICAL 13-1/16" CONNECTION 4-1116" � O 1/2" t 0 3/4 O O 2 1/16" 7/8" DIA. K.O. 3-15/16" 0 ELECTRICAL -1/2" \ \ 8-1/4" CONNECTION 1 � 40" (ALTERNATE) 314" 0 ; 3-3/4" 1-1/2° DIA. K.O. GAS CONNECTION ' 2-1/16" I } (ALTERNATE) 281/4" `)` I 28-1/4" 3/4" 22-1/2" 23-1 2" 5-5/16" 3-13/16" 1-1/2° DIA. HOLE �► 3/8" GAS CONNECTION 2-1/8" FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 TUD10OR948K 4 - HIGH - Black 1880 1846 1799 1740 1669 1595 1489 1381 1260 3 - MED. -HIGH - Blue 1662 1635 1598 1551 1493 1424 1345 1256 1157 2 - MED. -LOW - Yellow 1428 1421 1402 1370 1326 1269 1199 1117 1022 1- LOW -Red 1208 1215 1210 1193 1164 1124 1073 1009 935 © American Standard Inc. 2002 CFM VS. TEMPERATURE RISE CFM i CUBIC FEET PER MINUTE MODEL 1100 1200 1 1300 1400 1500 1600 1700 1800 1900 2000 TUD10OR948K 67 62 J 57 53 49 1 46 44 41 39 37 © American Standard Inc. 2002 • L J 17_� General Data o TYPE Upflow/ Horizontal RATINGS 2 1 st Stage Input BTUH 65,000 1st Stage Capacity BTUH (ICS) 3 52,000 2nd Stage Input BTUH 100,000 2nd Stage Capacity BTUH (ICS) 3 79,000 Temp. rise (Min. -Max.) °F. 35-65 BLOWER DRIVE DIRECT Diameter -Width (In.) 10 x 8 No. Used 1 Speeds (No.) 4 CFM vs. in. w.g. See Fan Performance Motor HP 1/2 R.P.M. 1075 Volts/Ph/Hz 115/1/60 COMBUSTION FAN -Type Centrifugal Drive - No. Speeds Direct - 2 Motor HP - RPM 1/50-3000 Volts/Ph/Hz 115/1/60 F.L. Amps 0.93 FILTER — Furnished? Yes Type Recommended High Velocity Hi Vel. (No: Size Thk.) Shipped 1 - 20x25 -1 in. VENT COLLAR — Size (in.) 4 Round HEAT EXCHANGER Type -Fired Alum. Steel -Unfired Gauge (Fired) 20 ORIFICES — Main Nat.Gas. Qty. — Drill Size 5-45 L.P. Gas Oty. — Drill Size 5-56 GAS VALVE Redundant - Two Stage PILOT SAFETY DEVICE Type Hot Surface Ignition BURNERS—Type Multiport Inshot Number 5 POWER CONN. — V/Ph/Hz * 115/1/60 Ampacity (In Amps) 12.0 Max. Overcurrent Protection (amps) 15 PIPE CONN. SIZE (IN.) 1/2 DIMENSIONS H x W x D Crated (in.) 41-3/4 x 23 x 30-1/2 Uncrated (In.) 40 x 21 x28 WEIGHT Shipping (Lbs.) / Net (Lbs) 162/151 O Central Furnace heating designs are certified by the American Gas Association Inc. Laboratories. OO Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% for each 1000 feet above sea level. O Based on U.S. Government Standard Tests. O The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. Mechanical Specifications NATURAL GAS MODELS—Central heat- ing furnace designs are certified by the American Gas Association for both natu- ral and L.P. gas. Limit setting and rating data were established and approved un- der standard rating conditions using Ameri- can National Standards Institute standards. SAFE OPERATION — The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combi- nation gas valve and regulator provide extra safety. QUICK HEATING— Durable, cycle tested, heavy gauge aluminized steel heat ex- changer quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside, allows com- mon venting with hot water heater. Technical Literature - Printed in U.S.A. American Standard Inc. The Trane Company 6200 Troup Highway Tyler, TX 75707 BURNERS — Multi -port, in -shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners. INTEGRATED SYSTEM CONTROL— Ex- clusively designed operational program pro- vides total control of furnace limit sensors, blowers, gas valve, flame control and in- cludes self diagnostics for ease of service. AIR DELIVERY — The multispeed, direct - drive blower motor, with sufficient airflow range for most heating and cooling re- quirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. (Fan relay and 35VA control transformer is stan- dard). STYLING — Heavy gauge steel and "wraparound" cabinet construction is used in the cabinet with baked -on enamel finish for strength and beauty. The heat exchanger section of the cabinet is com- pletely lined with foil -faced fiberglass insu- lation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. FEATURES AND GENERAL OPERA- TION — These High Efficiency Gas Fur- naces employ a Hot Surface Ignition sys- tem, which eliminates the waste of a con- stantly burning pilot. The integrated sys- tem control lights the main bumers upon a demand for heat from the room thermo- stat. Complete front service access. a. Low energy power venter. b. Vent proving differential switch. Since the Trane Company has a policy of continuous product improvement, it reserves the right to change specifications and design without notice. • • Project Name Date rRMETM Equipment Number Sales Office/Distributor SUBMITTAL Upflow / Horizontal Gas Furnace" Fan -Assisted Combustion" TUD10OR960K 4° DIAMETER FLUE CONNECT /1 6" 7/8° DIA. K.O. ELECTRICAL CONNECTION 40" (ALTERNATE) " 1-1/2" DIA. K.O. GAS CONNECTION (ALTERNATE) FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.) MODEL \ I 5-5/16" 0.20 0.30 0.40 0.50 0.60 1.1/2° DIA HOLE 0.80 0.90 GAS CONNECTION r3/8" 2-1/8" 2201 FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 TUD10OR960K 4 -HIGH -Black 2201 2146 2077 2026 1948 1882 1810 1738 1625 3 - MED. -HIGH - Blue 1943 1909 1857 1804 1786 1716 1659 1579 1506 2 - MED. -LOW - Yellow 1543 1520 1509 1490 1481 1460 1398 1356 1303 1- LOW -Red 1282 1272 1267 1268 1256 1226 1176 1163 1102 CFM V8. TEMPERATURE RISE CFM CUBIC FEET PER MINUTE MODEL 1200 1 1300 1400 1500 1600 1700 1 1800 1900 1 2000 2100 1 2200 2300 1 2400 TUD100R960K 62 1 57 53 49 46 44 1 41 39 1 37 35 1 34 1 32 1 31 © American Standard Inc. 2002 I General Data o TYPE Upf low / Horizontal RATINGS 2 1st Stage Input BTUH 65,000 1st Stage Capacity BTUH (ICS) 3 52,000 2nd Stage Input BTUH 100,000 2nd Stage Capacity BTUH (ICS) 3 80,000 Temp. rise (Min. -Max.) °F. 30-60 BLOWER DRIVE DIRECT Diameter -Width (In.) 11 X10 No. Used 1 Speeds (No.) 4 CFM vs. in. w.g. See Fan Performance Motor HP 1/2 R.P.M. 1075 Volts/Ph/Hz 115/1/60 COMBUSTION FAN - Type Centrifugal Drive - No. Speeds Direct - 2 Motor HP - RPM 1/50-3000 Votts/Ph/Hz 115/1/60 F.L. Amps 0.93 FILTER — Furnished? Yes Type Recommended High Velocity Hi Vel. (No: Size-Thk.) Shipped 1 - 20x25 -1 in. C: • VENT COLLAR — Size (in.) 4 Round HEAT EXCHANGER Type -Fired Alum. Steel -Unfired Gauge (Fired) 20 ORIFICES — Main Nat.Gas. Qty. — Drill Size 5-45 L.P. Gas Qty. — Drill Size 5-56 GAS VALVE Redundant - Two Stage PILOT SAFETY DEVICE Type Hot Surface Ignition BURNERS— Type Multiportlnshot Number 5 POWER CONN. — V/Ph/Hz * 115/1/60 Ampacity (In Amps) 12,8 Max. Overcurrent Protection (amps) 15 PIPE CONN. SIZE (IN.) 1/2 DIMENSIONS H x W x D Crated (In.) 41-3/4 x 23 x 30-1/2 Uncoated (in.) 40 x 21 x28 WEIGHT Shipping (Lbs.) / Net (Lbs) 162/151 O Central Furnace heating designs are certified by the American Gas Association Inc. Laboratories. ® Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% for each 1000 feet above sea level. O Based on U.S. Government Standard Tests. O The above wiring specifications are in accordance with National Electrical Code; however, Installations must comply with local codes. Mechanical Specifications NATURAL GAS MODELS —Central heat- ing furnace designs are certified by the American Gas Association for both natu- ral and L.P. gas. Limit setting and rating data were established and approved un- der standard rating conditions using Ameri- can National Standards Institute standards. SAFE OPERATION — The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combi- nation gas valve and regulator provide extra safety. QUICK HEATING— Durable, cycle tested, heavy gauge aluminized steel heat ex- changer quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside, allows com- mon venting with hot water heater. Technical Literature- Printed in U.S.A. American Standard Inc. The Trane Company 6200 Troup Highway Tyler, TX 75707 BURNERS — Multi -port, in -shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners. INTEGRATED SYSTEM CONTROL—Ex- clusively designed operational program pro- vides total control of furnace limit sensors, blowers, gas valve, flame control and in- cludes self diagnostics for ease of service. AIR DELIVERY—The multispeed, direct - drive blower motor, with sufficient airflow range for most heating and cooling re- quirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. (Fan relay and 35VA control transformer is stan- dard). STYLING — Heavy gauge steel and "wraparound" cabinet construction is used in the cabinet with baked -on enamel finish for strength and beauty. The heat exchanger section of the cabinet is com- pletely lined with foil -faced fiberglass insu- lation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. FEATURES AND GENERAL OPERA- TION — These High Efficiency Gas Fur- naces employ a Hot Surface Ignition sys- tem, which eliminates the waste of a con- stantly burning pilot. The integrated sys- tem control lights the main burners upon a demand for heat from the room thermo- stat. Complete front service access. a. Low energy power venter. b. Vent proving differential switch. Since the Trane Company has a policy of continuous product improvement, it reserves the right to change specifications and design without notice. 0 TRIINE' e TAG: L' C` NOTE: All dimensions are in mm/inches. ELECTRICAL AND REFRIGERANT COMPONENTCLEARANCES PER PREVAILING CODES. LIOUID L VALVE, T' BRAZE WITH 1/T PRESSURE IA Project Name Equipment Number Sales Office/Distributor UN11SHOULD DE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 112'1 FROM MALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNUSTRICIED. MODELS I BASE I A I B I C I D I E I F G H J 4TTX4024A 3 1016 829 756 5!8 5/16 143 92 210 79 (40) (32-5/8) (29-3/4) (5-5/8) (3-5/8) (8 114) (3 1/8) From Dwg. 21 D152635 Rev. 3 © 2002 American Standard Inc. All Rights Reserved Date 4TTX4024-SUB-100.00 2 Ton Split System Cooling —1 Phase 4TTX4024A Outdoor Unit 0@ 4TTX4024A1000A General Data SOUND RATING (DECIBELS) ® OO 78/78 POWER CONNS. — V/PH/HZ p 200/230/1/60 MIN, BIRCH. CIR. AMPACITY 13 BR. CIR. l MAX. (AMPS) 20 PROT. RTG. MIN. (AMPS) 20 COMPRESSOR CLIMATUFF" NO. USED - NO. SPEEDS 1 - 1 VOLTS/PH/HZ 200/230/1/60 R.L. AMPS O - L.R. AMPS 9.4-63 FACTORY INSTALLED START COMPONENTS O YES INSULATIONISOUND BLANKET YES COMPRESSOR HEAT YES OUTDOOR FAN —TYPE PROPELLER DIA. (IN.) - NO. USED 23-1 TYPE DRIVE - NO. SPEEDS DIRECT - 2 CFM @ 0.0 IN. W.G. O 2700 NO. MOTORS - HP. 1 - 1/8 MOTOR SPEED R.P.M. 825 VOLTS/PH/HZ 200/230/1/60 F.L. AMPS 0.9 OUTDOOR COIL —TYPE SPINE FINT"" ROWS - F.P.I. 1-24 FACE AREA (SQ. FT.) 18.71 TUBE SIZE (IN.) 5/16 REFRIGERANT R-41 OA (O.D. UNIT) NP CHRG. ® 5102-LB/OZ FACTORY SUPPLIED YES LINE SIZE - IN. O.D. GAS © 5/8 LINE SIZE - IN. O.D. LIQ. © 5/16 FCCV RESTRICTOR ORIFICE SIZE 0.053 DIMENSIONS H X W X D OUTDOOR UNIT CRATED (IN.) 44.3 X 30.1 X 33.8 UNCRATED SEE OUTLINE DWG. WEIGHT SHIPPING (LBS.) 239 NET (LBS.) 205 NOTES: OO CERTIFIED IN ACCORDANCE WITH THE UNITARY AIR -CONDITIONER EQUIPMENT CERTIFICATION PROGRAM WHICH IS BASED ON A.R.I. STANDARD 210/240. O RATED IN ACCORDANCE WITH A.R.I. STANDARD 270. OO CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE. ONLY USE HACR CIRCUIT BREAKERS OR FUSES. O STANDARD AIR - DRY COIL - OUTDOOR © THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT NAMEPLATE AND SERVICE INSTRUCTION. O MAX. LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR - 60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING SOFTWARE PUB. NO. 32-3312-01. OO THE VALUE SHOWN FOR COMPRESSOR FLA ON THE UNIT NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUIT SELECTION CURRENT. O NO MEANS NO START COMPONENTSYES MEANS QUICK START KIT COMPONENTS PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER. ON RATED IN ACCORDANCE WITH A.R.I. STANDARD 270/SECTION 5.3.6. 4TTX4024A With Cooling Coils RXCO26S3 RX0031S3 RXC036S3 RXC0.17S3 n=WA TXAU4C4 TX EWA EXPANSM TYPE TXV-NB TXV-NB TXV-NB TXV-NB CHG TO 53 CHG TO 53 CHG TO 53 RUI NGS (COOLILG) O • CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 BTUH (TOTAL) 23000 24800 25400 25400 22000 23400 23800 BTUH (SENSIBLE) 17200 19600 20000 20000 15800 17700 18000 INDOOR AIRFLOW (CFM) 800 900 900 900 675 800 800 SYSTEM POWER (KW) 2.19 2.25 2.27 2.27 2.13 2.23 2.23 EER / SEER (BTU/WATTHR.) 10.50112.25 11.00113.00 11.20113.25 11.20113.25 10.35111.25 10.50111.50 10.65111.75 • • TXCO204 TXCO25C4 TXCO25D4 TXC030C4 TXC03004 TXC031C4 1XC031D4 EXPANSION TYPE TXA030C4 TXA031C4 TXA035C4 TXA036C4 TXA037C4 TXC018C4 TXCO24C4 EXPRNSION TYPE CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 RKMGS (COOLING) O 23400 23800 23800 24400 24400 24600 24600 BTUH (TOTAL) 24400 24600 24400 24800 24800 22000 23400 BTUH (SENSIBLE) 19200 19400 19200 19600 19600 15800 17700 INDOOR AfRFLOW (CFM) 900 900 900 900 900 675 800 SYSTEM POWER (KW) 2.30 2.30 2.30 2.32 2.32 2.13 2.23 EER / SEER (BTU/WATTHR.) 10.60111.50 10.70111.50 10.60111.50 10.70111.50 10.70111.50 10.35111.25 10.50111.50 TXCO204 TXCO25C4 TXCO25D4 TXC030C4 TXC03004 TXC031C4 1XC031D4 EXPANSION TYPE CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 RARNGS (COOLING) O TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB BTUH (TOTAL) 23400 23800 23800 24400 24400 24600 24600 BTUH (SENSIBLE) 17700 18000 18000 19200 19200 19400 19400 INDOOR AIRFLOW (CFM) 800 800 800 900 900 900 900 SYSTEM POWER (KW) 2.23 2.23 2.23 2.30 2.30 2.30 2.30 EER I SEER (BTUANATFHR.) 10.50/11.50 10.65/11.75 10.65111.75 10.60111.50 10.60!11.50 10.701.50 10.70/11.50 TXC035C4 1X00357)4 TXC036C4 TXC0m TXC037C4 TXK025A4 TXHO&VW EXPANM TYPE CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 RAr NGS (COOLING) O TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB BTUH (TOTAL) 24400 24400 24800 24800 24800 23400 25000 BTUH (SENSIBLE) 19200 19200 19600 19600 19600 17700 19900 INDOOR AIRFLOW (CFM) 900 900 900 900 900 800 900 SYSTEM POWER (KW) 2.30 2.30 2.32 2.32 2.32 2.22 2.33 EER / SEER (BTU/WATTHR.) 10.60111.50 10.60111.50 10.7011 1.50 10.70111.50 10.70111.50 10.55111.50 10.75111.75 4TTX4024A With Air Handlers 12.30114.55 12.80115.00 11.20113.00 11.50/13.50 11.20/13.25 10.90112.75 EXPANSLON7YPE 4TEE3F31A 4TEE3F37A 4TEE3F40A 4TEP3F18A 4TEP3F24A 4TEP3F30A 4TEP3F35A EXPANSIONTYPE TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB RAMGS (COOLING) O 4TTX4024-SUB-100.00 BTUH (TOTAL) 25000 25000 16400 23800 24600 24800 24600 BTUH (SENSIBLE) 19400 19100 20200 17000 18700 19700 19400 INDOOR AIRFLOW (CFM) 835 800 815 675 800 900 900 SYSTEM POWER (KW) 2.07 2.03 2.06 2.13 2.14 2.21 2.26 EER / SEER (BTUANATFHR.) 12.10114.25 12.30114.55 12.80115.00 11.20113.00 11.50/13.50 11.20/13.25 10.90112.75 TVF018A14 TVF024A14 TVF02SA14 TVF03OA14 TVF036A14 TWE018C14 TWE024C14 EXPANSION TYPE CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 CHG TO 53 RATll m (COOLBIIG) O BTUH (TOTAL) 23800 24200 24400 25200 25200 21400 23200 BTUH (SENSIBLE) 17200 18400 18800 20300 20200 16000 17300 INDOOR AIRFLOW (CFM) 675 775 800 900 900 675 800 SYSTEM POWER (KW) 2.18 2.24 2.21 2.28 2.36 2.07 2.17 EER I SEER (BTU/WATT-HR.) 10.90/12.00 10.80112.00 11.05112.25 11.05/12.25 10.70112.00 10.80111.25 10.70112.00 7WE030C14 7WEMWI4 EXPANSLON7YPE CHG TO 53 CHG TO 53 RIDINGS (COOLING) O BTUH (TOTAL) 24200 24400 BTUH (SENSIBLE) 19200 19600 INDOOR AIRFLOW (CFM) 900 900 SYSTEM POWER (KW) 2.25 2.29 EER / SEER (BTUNVATFHR.) 10.75112.00 10.65112.00 Notes: O Certified in accordance with A.R.I. Standard 210/240. 2 4TTX4024-SUB-100.00 4TTX4024A With Furnaces & Coils MDMMV3 MDO60R9V3 TDD060R9V3 TDDVAMV3 MD06CROV3 TDD080R9V3 TDD080R9V3 +TXHUW +TXH033M +RXCO25S3 +RXC031S3 +RXC036S3 +TXH025M +TXH033A4 EXFRNSIDN TYPE CNG TO 53 CHG TO 53 TXV-NB TXVNB TXV-NB CHG TO 53 CHG TO 53 RATINGS (comm) O • BTUH (TOTAL) 24000 25200 23600 25000 25600 23800 25200 BTUH (SENSIBLE) 18200 19300 17800 19100 19400 17900 19100 INDOOR AIRFLOW (CFM) 800 800 800 800 800 770 775 SYSTEM POWER (KW) 2.06 2.09 2.05 2.06 2.06 2.03 2.08 EER / SEER (BTUIWATTHR.) 11.65/13.00 12.05113.50 11.50/13.50 12.15/14.50 12.45/15.00 11.70/13.25 12.10/13.75 TDD080ROV3 TDD080ROV3 TDD080ROV3 TDY0MV3 TDU060ROV3 TDY060R9V3 TDY06DRBV3 +RXCOM +RXC031S3 +RXC036S3 +TXH025M +TXHMA4 +RXCO25S3 +RXC031S3 EXPANSION TYPE TXV-NB TXV-NB TXV-NB CHG TO 53 CNG TO 53 TXV-NB TXV-NB RATINGS (COOLING) O BTUH (TOTAL) 23400 25000 25600 23400 24800 23000 24600 BTUH (SENSIBLE) 17400 18800 19200 17000 18100 16600 17900 INDOOR AIRFLOW (CFM) 760 770 780 700 700 700 700 SYSTEM POWER (KW) 2.02 2.05 2.05 2.01 2.06 2.00 2.03 EER / SEER (BTUMATTHR.) 11.60/13.75 12.20/14.50 12.50115.00 11.65/13.00 12.05/13.50 11.50113.50 12.10/14.25 TDNO60R9V3 TOY080R9V3 TDN080MV3 TDI(0OMM TDN080R9V3 TDNOBORSV3 TUD060R9V3 +RXCO36S3 +TXH025M +TXH033A4 +RXCO26S3 +RXC031S3 +RXC036S3 +TXH025M EXPANSION TYPE TXV-NB CHG TO 53 CHG TO 53 TXV-NB TXV-NB TXV-NB CHG TO 53 RATINGS (COOLDIq O BTUH (TOTAL) 25000 23400 24800 23000 24600 25000 24000 BTUH (SENSIBLE) 18000 17000 18200 16600 17900 18000 18200 INDOOR AIRFLOW (CFM) 700 700 710 700 700 700 800 SYSTEM POWER (KW) 2.02 2.01 2.07 1.99 2.02 2.02 2.07 EER / SEER (BTU/WATT-HR.) 12.35fl4.75 11.65!13.00 12.00113.50 11.55113.50 12.20!14.50 12.40/14.75 11.60!13.00 TUD060R9V3 TUDDSMV3 TUD060R9V3 TUD060RM TUD080R9V3 TUD080R9V3 TUD08OR9V3 +TXH033A4 +RXCO2553 +RXC031S3 +RXC036S3 +TXH025M +TXH033A4 +RXCO25S3 EXPANSION TYPE CHG TO 53 TXIFNB TXV-NB TXVNB CHG TO 53 CHG TO 53 TWNB RATINGS (COOLING) O BTUH (TOTAL) 25200 23600 24600 25600 24000 25200 23600 BTUH (SENSIBLE) • 19300 17800 17900 19600 18200 19300 17800 INDOOR AIRFLOW (CFM) 800 800 700 825 800 800 800 SYSTEM POWER (KW) 2.11 2.04 2.03 2.08 2.08 2.12 2.05 EER / SEER (BTU/WATFHR.) 11.95113.50 11.55/13.50 12.10/14.00 12.30114.50 11.55/13.00 11.90113.50 11.50/13.50 TUD08MV3 TUD080RBV3 TUY060ROV3 TUY060R9V3 TUY060R9V3 TUY060ROV3 TUY060R9V3 +RXC031S3 +RXC036S3 +TXH025M +TXH033A4 +RXCO25S3 +RXC031S3 +RXCO36S3 EXPANSION TYPE TXV-NB TXV-NB CHG TO 53 CHG TO 53 TXV-NB TXV-NB TXV-NB RAMGS (COOLMO O BTUH (TOTAL) 25000 25600 23600 24800 23200 24400 25000 BTUH (SENSIBLE) 19000 19500 17300 18200 16900 17700 18000 INDOOR AIRFLOW (CFM) 800 815 720 715 725 700 700 SYSTEM POWER (KW) 2.08 2.06 2.04 2.08 2.04 2.04 2.05 EER / SEER (BTUANATFHR.) 12.00114.25 12.40114.75 11.55113.00 11.90113.50 11.35113.50 11.95114.00 12.20/14.50 TUY080R9V3 TUY0800113 TUY080R9V3 TUY080R9V3 TUY080R9V3 +TXH025M +TXH033A4 +RXCO25S3 +RXC031S3 +RXC036S3 EXR%NM TYPIE CHG TO 53 CHG TO 53 TXVNB TXV-NB TXVNB RIUINGs (cooum) O BTUH (TOTAL) 23400 24800 23000 24600 25000 BTUH (SENSIBLE) 17000 18200 16600 17900 18000 INDOOR AIRFLOW (CFM) 700 705 700 700 700 SYSTEM POWER (KW) 2.01 2.06 1.99 2.03 2.02 EER / SEER (BTU/WATT-HR.) 11.65113.00 12.05/13.50 11.55/11.50 12.10/14.25 12.35/14.75 Notes: O Certified in accordance with A.R.I. Standard 210/240. • 4TTX4024-SUB-100.00 C Mechanical Specification Options General The 4TTX4 shall be fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit must be designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities shall be matched with a wide selection of air handlers and furnace coils that are A.R.I. certified. The unit shall be UL listed. Exterior must be designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint. Corrosion and weatherproof CMBP-G30 DuratuffTm Base. Refrigerant Controls Refrigeration system controls include condenser fan and compressor contactor. High and low pressure controls are inherent to the compressor. Another standard feature is the liquid line dryer. Compressor The Climatuff® compressor features internal over temperature and pressure protector, total dipped hermetic motor and thermostatically controlled sump heater. Other features include: roto lock suction and discharge refrigeration connections, centrifugal oil pump, and low vibration and noise. The Climatuff9 compressor is standard with a 10 year limited warranty. o y�s�alloaav .e Condenser Coil The Spine Fin TM coil shall be continuously wrapped, corrosion resistant all alumi- num with minimum brazed joints. This coil is 5/16 inch O.D. seamless aluminum glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is pro- tected on all four sides by louvered panels and has a 10 year limited warranty. Low Ambient Cooling As manufactured, this unit has a cooling capability to 55°F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. Accessories Thermostats — Heating/Cooling (manual and automatic changeover). Sub -base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. Outdoor Thermostat — Supplemental heat outdoor ambient lockout from 46 to –10°F. Wane • A business of American Standard Companies Trane has a policy of continuous product and product data improvement and it reserves the right to change www.trane.com design and specifications without notice. 0 T/Pllll/E. . TAG: • NOTE: All dimensions are in mm/inches. SERVICE PANEL [it C fRICAt AND RHAIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. EIOUID I VALVE, F BRAIC WITH I/t PRESSURE TA Project Name Equipment Number Sales Office/Distributor UNIT RUN .OFFULD WATtR OOESENOtOPOT DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 112.1 fRON WALL AHD ALL SURROUNDING SHRUBBERY ON TWO SIDES, OTHER TWO SIDES UNBE STRICTED. MODELS BASEI A 1 B C I D 1 E I F I G I HJ 4TTX4036A 3 1118 829 756 3/4 y8 143 92 210 79 (44) (32-5/8) (29 4/4) (5-5(8) (35/8) (8-1/4) (3-1(6) From Dwg. 21D152635 Rev. 3 ED 2002 American Standard Inc. All Rights Reserved Date 4TTX4036-SUS-100.00 3 Ton Split System Cooling —1 Phase 4TTX4036A Outdoor Unit I 4TTX4036A1000A General Data SOUND RATING (DECIBELS) ® O 74172 POWER CONNS. — V/PH/HZ O 208/230/1160 MIN. BRCH. CIR. AMPACITY 21 BR. CIR. 1 MAX. (AMPS) 35 PROT. RTG. J MIN. (AMPS) 30 COMPRESSOR CLIMATUFF° - SCROLL NO. USED - NO. SPEEDS 1 - 1 VOLTS/PH/HZ 208/230/1160 R.L. AMPS OO - L.R. AMPS 15.4-83 FACTORY INSTALLED ROWS - F.P.I. START COMPONENTS O NO INSULATIONISOUND BLANKET YES COMPRESSOR HEAT NO OUTDOOR FAN — TYPE PROPELLER DIA. (IN.) - NO. USED 23-1 TYPE DRIVE - NO. SPEEDS DIRECT - 2 CFM @ 0.0 IN. W.G. ® 3100 NO. MOTORS - HP. 1 - 1/6 MOTOR SPEED R.P.M. 825 VOLTS/PH/HZ 200/230/1/60 F.L. AMPS 1.4 OUTDOOR COIL — TYPE SPINE FINTM ROWS - F.P.I. 1-24 FACE AREA (SO. FT.) 21.20 TUBE SIZE (IN.) 5116 REFRIGERANT R -410A (O.D. UNIT) NP CHRG. ® 5/11-LB/OZ FACTORY SUPPLIED YES LINE SIZE - IN. O.D. GAS © 3/4 LINE SIZE - IN. O.D. LIQ. © 3/8 FCCV RESTRICTOR ORIFICE SIZE 0.065 DIMENSIONS H X W X D OUTDOOR UNIT CRATED (IN.) 48.3 X 30.1 X 33.8 UNCRATED SEE OUTLINE DWG. WEIGHT SHIPPING (LBS.) 255 NET (LBS.) 219 NOTES: O CERTIFIED IN ACCORDANCE WITH THE UNITARY AIR -CONDITIONER EQUIPMENT CERTIFICATION PROGRAM WHICH IS BASED ON A,R.1. STANDARD 210240. O RATED IN ACCORDANCE WfTH A.R.I. STANDARD 270. OO CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE. ONLY USE HACR CIRCUIT BREAKERS OR FUSES. O STANDARD AIR - DRY COIL - OUTDOOR © THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT NAMEPLATE AND SERVICE INSTRUCTION. © MAX. LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR - 60 FT WITH SCROLL. MAX. LIFT- SUCTION 60 FT; MAX LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFERTO REFRIGERANT PIPING SOFTWARE PUB. NO. 32-3312-01, OO THE VALUE SHOWN FOR COMPRESSOR RLAONTHE UNIT NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUIT SELECTION CURRENT. O NO MEANS NO START COMPONENTSYES MEANS QUICK START KIT COMPONENTS PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER. OO RATED IN ACCORDANCE WITH A.R.I. STANDARD 270/SECTION 5.3.6. 4TTX4036A With Cooling Coils EXHMON TYPE RXC031S3 RXC036S3 RXC037S3 RXCOSM TXA030CA TXA031C4 7XA035G EXPANSION TYPE TXV-NB TXV-NB TXV-NB TXV-NB CHG TO 65 CHG TO 65 CHG TO 65 RATINGS (COOLMG) O • 1350 SYSTEM POWER (KW) 3.26 3.41 EER / SEER (BTUIWATFHR.) 10.85112.25 10.85112.00 BTUH (TOTAL) 35200 36400 36400 36800 34600 35000 34600 BTUH (SENSIBLE) 26100 27700 27700 29000 25300 15700 25300 INDOOR AIRFLOW (CFM) 1110 1200 1200 1350 1100 1100 1100 SYSTEM POWER (KW) 3.20 3.26 3.26 3.32 3.22 3.24 3.22 EER / SEER (BTUIWATFHR) 11.00113.00 11.15/13.25 11.15/13.25 11.10/13.00 10.75112.00 10.80/12.00 10.75/12.00 EXHMON TYPE TXA035C4 TXA03M TXA84M TXA043C4 TXA04SC4 TXA049C4 TXA950C1 EXPANSIONTYPE CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 RATINGS (COOLgq O 1350 SYSTEM POWER (KW) 3.26 3.41 EER / SEER (BTUIWATFHR.) 10.85112.25 10.85112.00 BTUH (TOTAL) 35600 35600 36000 36400 37000 37000 37000 BTUH (SENSIBLE) 27000 27000 27300 28800 29300 29300 29300 INDOOR AIRFLOW (CFM) 1200 1200 1200 1350 1350 1350 1350 SYSTEM POWER (KW) 3.30 3.30 3.30 3.39 3.41 3.41 3.41 EER I SEER (BTUIWATTHR.) 10.80/12.00 10.80112.00 10.90112.00 10.75/12.00 10.85112.00 10.85112.00 10.85112.00 4TTX4036-SUFI-100.00 TXC03OC4 TXC030D4 TXC031C4 TXC031D4 TXC035C4 TXC085W TXC036C4 EXPANSION TYPE CHG TO 65 CHG TO 65 CNG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 RATINGS (COOLING) O BTUH (TOTAL) 34600 34600 35000 35000 34600 34600 35600 BTUH (SENSIBLE) 25300 25300 25700 25700 25300 25300 27000 INDOOR AIRFLOW (CFM) 1100 1100 1100 1100 1100 1100 1200 SYSTEM POWER (KW) 3.22 3.22 3.24 3.24 3.22 3.22 3.30 EER I SEER (BTU/WATT-HR,) 10.75!12.00 10.75/12.00 10.80/12.00 10.80112.00 10,75112.00 10.75/12.00 10.80/12.00 TXCOS6D1 TXC037C4 TXC04ZC4 TXC04= TXC0/BC4 TXCO49C4 TXCOWA EXPANSIONTYPE CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 RATINGS (COOLDNG) O • BTUH (TOTAL) BTUH (SENSIBLE) 35600 27000 35600 27000 36000 27300 36400 28800 37000 29300 37000 29300 37000 29300 INDOOR AIRFLOW (CFM) 1200 1200 1200 1350 1350 1350 1350 SYSTEM POWER (KW) 3.30 3.30 3.30 3.39 3.41 3.41 3.41 EER I SEER (BTU/WAIT-HR.) 10.80112.00 10.80112.00 10.90112.00 10.75112.00 10.85112.00 10.85/12.00 10.85112.00 EXHMON TYPE TXH003A4 TXH041A4 EXPANSION TYPE CHG TO 65 CHG TO 65 RATINGS (COOLING) O 4TEP3F42A EXPANSION TYPE BTUH (TOTAL) 35400 37000 BTUH (SENSIBLE) 26500 29600 INDOOR AIRFLOW (CFM) 1125 1350 SYSTEM POWER (KW) 3.26 3.41 EER / SEER (BTUIWATFHR.) 10.85112.25 10.85112.00 4TTX4036A With Air Handlers 35400 EXHMON TYPE 4TEESF31A 4TEE3F37A 4TEESF40A 4TEE3F49A 4TEP3F30A 4TEP3F36A 4TEP3F42A EXPANSION TYPE TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB RATINGS (CODL#q O 37000 35600 36400 33400 35200 36400 36800 BTUH (TOTAL) 35400 35800 37800 38000 34200 35200 36600 BTUH (SENSIBLE) 27200 27100 29100 29100 24000 26700 29200 INDOOR AIRFLOW (CFM) 1220 1160 1200 1200 940 1200 1350 SYSTEM POWER (KW) 3.19 3.06 3.09 3.05 3.08 3.23 3.33 EER / SEER (BTUIWATTHR.) 11.10113.00 11.70114.00 12.25/14.50 12.45114.75 11.10/13.00 10.90112.75 11.00113.00 4TTX4036-SUFI-100.00 4TEP3F49A TVF030A14 1WO35A14 TNNEO30C14 TWE03SC14 TWEO42C14 IWE04SC14 EXHMON TYPE TXV-NB CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 RATINGS ((DOLING) O BTUH (TOTAL) 37000 35600 36400 33400 35200 36400 36800 BTUH (SENSIBLE) 29500 26800 28000 23400 27200 29300 29600 INDOOR AIRFLOW (CFM) 1350 1125 1200 945 1200 1350 1350 SYSTEM POWER (KW) • 3.26 3.30 3.35 3.08 3.26 3.39 3.44 EER 1 SEER (BTUIWATTHR.) 11.35113.25 10.80112.25 10.85112.25 10.85112.25 10.80112.25 10.75112.00 10.70/12.00 Notes: O Certified in accordance with A.R.I. Standard 210/240. 2 4TTX4036-SUFI-100.00 4TTX4036A With Furnaces & Coils TOY100R8V4 TUD060R9V3 TUD060RM TUD060ROV3 TUD060R9V3 TUDOSOROV3 TW060RM TD0o6o M iDD0MV3 iDDO MV3 MD080R9V3 MD0 OV3 MD0MV3 +TXH033M +TXH033M +TXH04IA4 +RXC031S3 +RXC036S3 +TXH033A4 +T)MIA4 +RXC03iS3 EXPANSION TYPE CHG TO 65 CHG TO 65 TXV-NB TXV-NB CHG TO 65 CHG TO 65 TXV-NB RJOTNGS (COOLNG) O 36800 BTUH (SENSIBLE) • 26300 28100 28800 27400 27900 BTUH (TOTAL) 36000 37000 35800 36600 35800 36800 35600 BTUH (SENSIBLE) 27700 28400 27400 27900 26900 27700 26600 INDOOR AIRFLOW (CFM) 1200 1200 1200 1200 1125 1140 1120 SYSTEM POWER (KW) 3.19 3.19 3.17 3.16 3.13 3.15 3.11 EER I SEER (BTUANATTHR.) 11.30/13.00 11.60113.25 11.30/13.25 11.60113.75 11.45113.00 11.70113.50 11.45/13.50 TUYO609113 TUYO60 n +RXC031S3 +RXC036S3 +TXH033A4 +TXHWiM +RXC037S3 +TXH033141 TDDOBORDV3 TDD100ROV5 iDD100ROV5 TDD100MV5 TOY060RIV3 TDY060 n TDYO60R9V3 CHG TO 65 +RXC036S3 +TXH033A4 +TXH041A4 +RXC037S3 +TXH033A4 +T)G WIA4 +RX0031S3 EXPANSION TYPE TXV-NB CHG TO 65 CHG TO 65 TXV-NB CHG TO 65 CHG TO 65 TXV-NB RKMGS (COOLNG) O 36200 BTUH (SENSIBLE) 27400 27900 27900 28600 27600 BTUH (TOTAL) 36600 35800 37200 37000 35600 36400 35600 BTUH (SENSIBLE) 27300 27000 28600 28100 26400 26800 26300 INDOOR AIRFLOW (CFM) 1130 1130 1200 1180 1080 1070 1090 SYSTEM POWER (KW) 3.10 3.13 3.11 3.05 3.11 3.11 3.11 EER / SEER (BTUANATFHR.) 11.80114.00 11.45113.25 11.95/14.00 12.15/14.50 11.45113.00 11.70113.50 11.45113.50 TUY080R9113 TUY100RW4 +RXC031S3 +RXC036S3 +7X11033A4 +TXH04iA4 +RXC031S3 +RXC036S3 TDY060R9V3 TDY080RM TDYO800V3 TDY08OR1113 TDY080RVV3 TDnDMV4 iDnOORW4 TXV-NB +RXCO36S3 +TXH03314 +TXHMA4 +RXC031S3 +RXC0M +TXH033M +TXH04iA4 EXPANSIONTYPE TXV-NB CHG TO 65 CHG TO 65 TXV-NB TXV-NB CHG TO 65 CHG TO 65 RMWM (COOUM O 35600 BTUH (SENSIBLE) 25800 26300 25400 26300 25700 BTUH (TOTAL) 36200 35400 36400 35200 36000 35400 36400 BTUH (SENSIBLE) 26600 26400 27000 25600 26100 26000 26600 INDOOR AIRFLOW (CFM) 1085 1100 1100 1050 1050 1050 1050 SYSTEM POWER (KW) 3.09 3.16 3.18 3.14 3.13 3.08 3.11 EER / SEER (BTU/WArTHR.) 11.70/14.00 11,20/13.00 11.45/13.00 11.20113.00 11.50113.50 11.50/13.25 11.70/13.50 TOY100R8V4 TUD060R9V3 TUD060RM TUD060ROV3 TUD060R9V3 TUDOSOROV3 TUD080R9V3 +RXC037S3 +TXH033A4 +TXHWiM +RXC031S3 +RXC0SMS +TXH033M +TXH041M EXPANSION TYPE TXV-NB CHG TO 65 CHG TO 65 TXV-NB TXV-NB CHG TO 65 CHG TO 65 RMM (COOLING) O BTUH (TOTAL) 36200 36000 37000 35800 36600 36000 36800 BTUH (SENSIBLE) • 26300 28100 28800 27400 27900 27700 28200 INDOOR AIRFLOW (CFM) 1050 1250 1250 1200 1200 1200 1200 SYSTEM POWER (KW) 3.07 3.27 3.27 3.20 3.20 3.20 3.20 EER / SEER (BTLYWAITHR.) 11.80114.00 11.00/12.50 11.30113.00 11.20/13.00 11.45/13.50 11.25/13.00 11.50/13.25 TUOOBORll113 TUD0800113 TUD100 115 TUD10N M WIVIDDR/VS TUYO609113 TUYO60 n +RXC031S3 +RXC036S3 +TXH033A4 +TXHWiM +RXC037S3 +TXH033141 +TXH041M EXPANSION TYPE TXV-NB TXV-NB CHG TO 65 CHG TO 65 TXVNB CHG TO 65 CHG TO 65 MOM (COOLNG) O BTUH (TOTAL) 35800 36600 36200 37200 37200 35400 36200 BTUH (SENSIBLE) 27400 27900 27900 28600 27600 26100 26300 INDOOR AIRFLOW (CFM) 1200 1200 1200 1200 1110 1070 1025 SYSTEM POWER (KW) 3.20 3.21 3.12 3.14 3.14 3.12 3.07 EER / SEER (BTUfW/9THR.) 11,20113.00 11.40113.25 11.60113,50 11.85113.75 11.85/14.00 11.35/13.00 11.80113.50 TUY060M TUY060R9V3 TUY080R9V3 TUYOSOR9V3 TUYO80ROV3 TUY080R9113 TUY100RW4 +RXC031S3 +RXC036S3 +7X11033A4 +TXH04iA4 +RXC031S3 +RXC036S3 +TXH033M E7DYINSIDN TYPE TWNB TXV-NB CHG TO 65 CHG TO 65 TXV-NB TXV-NB CHG TO 65 RATNGS (COOLMIM O BTUH (TOTAL) 35400 36200 35200 36200 35400 36200 35600 BTUH (SENSIBLE) 25800 26300 25400 26300 25700 26200 26200 INDOOR AIRFLOW (CFM) 1050 1050 1000 1025 1040 1040 1050 SYSTEM POWER (KW) 3.11 3.09 3.06 3.07 3.08 3.08 3.07 EER / SEER (BTUIWAfFHR.) 11.40113.50 11.70114.00 11.50/13.25 11.80/13.50 11.50113.50 11.75114.00 11.60113.50 TUY100RVV4 TUYiOO SY4 +TXRMA4 +RXC037S3 EXPANSIONTYPE CHG TO 65 TXV-NB WIM (COOLING) O BTUH (TOTAL) 36400 36400 BTUH (SENSIBLE) 26600 26600 INDOOR AIRFLOW (CFM) SYSTEM POWER 1050 1060 EER / SEER (BTUMATT-HR.) 11.8513.75 12.10/14.50 4TTX4O36-SUB-100.00 Notes: O Certified in accordance with A.R.I. Standard 210/240. 3 Mechanical Specification Options General The 4TTX4 shall be fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit must be designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities shall be matched with a wide selection of air handlers and furnace coils that are A.R.I. certified. The unit shall be UL listed. Exterior must be designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint. Corrosion and weatherproof CMBP-G30 Duratuff"'m Base. Refrigerant Controls Refrigeration system controls include condenser fan and compressor contactor. High and low pressure controls are inherent to the compressor. Another standard feature is the liquid line dryer. Compressor The Climatuff® compressor features internal over temperature and pressure protector, total dipped hermetic motor and thermostatically controlled sump heater. Other features include: roto lock suction and discharge refrigeration connections, centrifugal oil pump, and low vibration and noise. The Climatuff® compressor is standard with a 10 year limited warranty. 0 'y S)4,1DP��2 Condenser Coil The Spine FnTM coil shall be continuously wrapped, corrosion resistant all alumi- num with minimum brazed joints. This coil is 5/16 inch O.D. seamless aluminum glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is pro- tected on all four sides by louvered panels and has a 10 year limited warranty. Low Ambient Cooling As manufactured, this unit has a cooling capability to 55°F. The addition of an evaporator defrost control permits operation to 40'F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. Accessories Thermostats — Heating/Cooling (manual and automatic changeover). Sub -base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. Outdoor Thermostat — Supplemental heat outdoor ambient lockout from 46 to –10'F. Wane A business of AmerteanStandard Companies Trane has a policy of continuous product and product data improvement and it reserves the right to change www.bane.com design and specifications without notice. • TAG: • • NOTE: All dimensions are in mm/inches. ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PEN PREVAILING CODES. LIQUID LINE SERV VALVE. BNF IE C.DI. CCM SAE CL. AFL WITH ITA' SAE PRESSURE TAP FIiT INi Project Name Equipment Number Sales Office/Distributor UNITSHOULD 8E PLACED SO HOOF RUN .OFF NATER DOCS NOT POUR DIRECTLY ONUNIT. AND SHOULD BE AT LEAST 305 112'1 FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES ONCSTRICTED. MODELS BASE A B C I D I E I F I G I H J 47TX4048A 1 4 1 1267 946 870 7/8 3/8 152 98 219 86 (49-7/8) (37-1/4) (341/4) (6) (3-7/8) (8-5/8) From DWO. 21 D152635 Rev.: IOWA wW c�l us © 2002 American Standard Inc. All Rights Reserved Date 0 4TTX4048-SUB-100.00 4 Ton Split System Cooling —1 Phase 4TTX4048A Outdoor Unit o0 4TTX4048A1000A General Data SOUND RATING (DECIBELS) ®O 7805 POWER CONNS. — WPH/HZ O 208/230/1/60 MIN. BIRCH. CIR. AMPACITY 27 BR. CIR. t MAX. (AMPS) 45 PROT. RTG. J MIN. (AMPS) 40 COMPRESSOR CLIMATUFF® - SCROLL NO. USED - NO. SPEEDS 1 - 1 VOLTS/PH/HZ 2081230/1/60 R.L. AMPS OO - L.R. AMPS 20.5-109 FACTORY INSTALLED START COMPONENTS O NO INSULATION/SOUND BLANKET YES COMPRESSOR HEAT NO OUTDOOR FAN —TYPE PROPELLER DIA. (IN.) - NO. USED 27.6-1 TYPE DRIVE - NO. SPEEDS DIRECT - 2 CFM @ 0.0 IN. W.G. O 4400 NO. MOTORS - HP. 1 - 1/6 MOTOR SPEED R.P.M. 825 VOLTS/PH/HZ 200/230/1/60 F.L. AMPS 1.4 OUTDOOR COIL —TYPE SPINE FINTM ROWS - F.P.I. 1-24 FACE AREA (SQ. FT.) 27.81 TUBE SIZE (IN.) 5/16 REFRIGERANT R-41 OA (O.D. UNIT) NP CHRG. ® 7/15-LB/OZ FACTORY SUPPLIED YES LINE SIZE - IN. O.D. GAS © 7/8 UNE SIZE - IN. O.D. LIQ. © 3/8 FCCV RESTRICTOR ORIFICE SIZE 0.075 DIMENSIONS H X W X D OUTDOOR UNIT CRATED (IN.) 54 X 35.1 X 38.7 UNCRATED SEE OUTLINE DWG. WEIGHT SHIPPING (LBS.) 310 NET (LBS.) 262 NOTES: O CERTIFIED IN ACCORDANCE WITH THE UNITARY AIR -CONDITIONER EQUIPMENT CERTIFICATION PROGRAM WHICH IS BASED ON A.R.I. STANDARD 210/240. 90 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270. OO CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE. ONLY USE HACR CIRCUIT BREAKERS OR FUSES. O STANDARD AIR - DRY COIL - OUTDOOR © THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT NAMEPLATE AND SERVICE INSTRUCTION. O MAX. LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR - 60 FT WITH SCROLL. MAX. LIFT 'SUCTION 60 FT; MAX LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING SOFTWARE PUB'NO. 32-3312-01. (2) THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUIT SELECTION CURRENT. OO NO MEANS NO START COMPONENTSYES MEANS QUICK START KIT COMPONENTS PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER. O RATED IN ACCORDANCE WITH A.R.I. STANDARD 270/SECTION 5.3.6. 4TTX4048A With Cooling Coils mom RXAo61S3 RXCUM RXC060S3 RXC061S3 RXC065S3 RXIIOM EXMNSIONTYPE TXUNB TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB RKMGS (COOUNG) O • BTUH (TOTAL) 47000 48500 48500 BTUH (TOTAL) 48000 49000 48000 48000 49000 49000 50000 BTUH (SENSIBLE) 36800 39000 36000 36800 39000 39000 40100 INDOOR AIRFLOW (CFM) 1700 1800 1600 1700 1800 1800 1800 SYSTEM POWER (KW) 4.23 4.28 4.19 4.23 4.28 4.28 4.27 EER I SEER (BTU/WATT-HR.) 11.35113.50 11.45113.50 11.45113.50 11.35113.50 11.45113.50 11.45113.50 11.70114.00 TXA042C4 TXAG43C4 TXA048C4 TXA049C4 TXA050C4 TXC04ZC4 TXC043C4 EXRANSION TYPE CHG TO 75 CHG TO 75 CHG TO 75 CHG TO 75 CHG TO 75 CHG TO 75 CHG TO 75 RKMGS (COOUNG) O BTUH (TOTAL) 47000 48500 48500 BTUH (TOTAL) 45500 47500 47000 48500 48500 45500 47500 BTUH (SENSIBLE) 31200 35500 33300 36500 36500 31200 35500 INDOOR AIRFLOW (CFM) 1200 1575 1350 1600 1600 1200 1575 SYSTEM POWER (KW) 4.04 4.28 4.16 4.35 4.35 4.04 4.28 EER 1 SEER (BTU/WATFHR.) 11.25112.50 11.10112.50 11.30/12.75 11.15/12.50 11.15112.50 11.25112.50 11.10/12.50 TXC04BC4 TXC049C4 TXC0m TXH041A4 TXHOSW EXPIINSIONTYPE CHG TO 75 CHG TO 75 CHG TO 75 CHG TO 75 CHG TO 75 RIMGS (COOLING) OO CHG TO 75 RAnNGS (COOLING) O BTUH (TOTAL) 47000 48500 48500 48000 50000 BTUH (SENSIBLE) 33300 36500 36500 36300 39600 INDOOR AIRFLOW (CFM) 1350 1600 1600 1575 1700 SYSTEM POWER (KW) 4.16 4.35 4.35 4.30 4.46 EER / SEER (BTUANATFHR.) 11.30/12.75 11.15!12.50 11.15t12.50 11.15/72.50 11.20/12.50 4TTX4048A With Air Handlers 4.19 4.46 4.35 4.34 QMF49A 4TMF66A 4TEP3F47A 4TEM48A 4TMF63A ME042C14 ME048C14 EXPAN90NTYPE TXV-NB TXV•NB TXV-NB TXV-NB TXV-NB CHG TO 75 CHG TO 75 RAnNGS (COOLING) O BTUH (TOTAL) 50000 50500 47500 48000 50000 47000 48000 BTUH (SENSIBLE) • 37400 38900 35800 36400 39900 35600 36700 INDOOR AIRFLOW (CFM) 1500 1640 1575 1600 1800 1575 1600 SYSTEM POWER (KW) 3.98 4.09 4.22 4.19 4.46 4.35 4.34 EER I SEER (BTUANArTHR.) 12.55115.00 12.35/14.75 11.25113.00 11.45113.00 11.20/13.00 10.80112.25 11.05112.50 Notes: O Certified in accordance with A.R.I. Standard 210/240. • 4TTX4048-SUB-100.00 • • • 4TTX4048A With Furnaces & Coils EXAANSIONTYPE TD010DR9V5 +TXH041A4 TDO1000115 430054A4 TDD100R9V5 +RXC037S3 TDD100R9V5 +RXC054S3 TDD100R9V5 +RXH063S3 TDD120119V5 +TXH041A4 TDD120R9V5 +TXHO54A4 EVANSION TYPE CHG TO 75 CHG TO 75 TXVNB TXVNB TXILNB CHG TO 75 CHG TO 75 RATINGS (COOLING) O TXV-NB CHG TO 75 CHG TO 75 TXV-NB TXV-NB TXV-NB CHG TO 75 BTUH (TOTAL) 48500 50000 48500 48500 50000 48500 50000 BTUH (SENSIBLE) 37000 38600 37100 36600 38300 37000 38700 INDOOR AIRFLOW (CFM) 1600 1600 1620 1620 1600 1600 1600 SYSTEM POWER (KW) 4.20 4.35 4.15 4.15 4.12 4.15 4.27 EER / SEER (BTUANATTHR.) 11.55113.25 11.50113.25 11.70114.00 11.70/14.00 12.15/14.50 11.70113.50 11.70113.50 EXAANSIONTYPE MD12DROVS TDY100R9V4 Tvn00R9V4 TDY100Rm TW700R8V4 TDn00R9V4 Tgn20R9V5 BTUH (TOTAL) +RXH063S3 +TXH041A4 +TXH054A4 +RXC037S3 +RXC054S3 +RXH063S3 +TXHD41A4 EXPANSION TYPE TXV-NB CHG TO 75 CHG TO 75 TXV-NB TXV-NB TXV-NB CHG TO 75 RATINGS (COOLING) OO 11.75113.50 12.25114.50 12.05114.25 I BTUH (TOTAL) 50500 47500 49000 47500 47500 49000 47500 BTUH (SENSIBLE) 39000 34900 36400 34800 34400 36000 34600 INDOOR AIRFLOW (CFM) 1625 1450 1450 1450 1450 1450 1410 SYSTEM POWER (KW) 4.06 4.19 4.28 4.11 4.11 4.08 4.11 EER / SEER (BTU/WATT-HR.) 12.45115.00 11.35113.00 11.45113.00 11.55113.75 11.55113.75 12.00114.25 11.55113.25 Tgn20R9V5 TDY120R9V5 TUDIDDROV5 TUD100ROV5 TUD100R9V5 TUD100R9V5 TUDIDDR9V5 +TXH054A4 +RTDN063SE +TXH041A4 +TXHOS4A4 +RXC037S3 +RXC054S3 +RXHD63S3 EURNSION TYPE CHG TO 75 TXV-NB CHG TO 75 CHG TO 75 TXVNB TXV-NB TXV-NB RATINGS (COOLING) O BTUH (TOTAL) 49000 49000 48500 50000 48500 48000 49500 BTUH (SENSIBLE) 36100 35700 37600 39100 37500 36600 37800 INDOOR AIRFLOW (CFM) 1415 1405 1670 1650 1670 1670 1600 SYSTEM POWER (KW) 4.22 4.03 4.27 4.39 4.18 4.19 4.16 EER / SEER (BTU/WATI:HR.) 11.60113.25 12.15/14.50 11.35/13.00 11.40/13.00 11.60/13.75 11.45/13.50 11.90/14.00 TUD120R9V5 TUD120R9V5 TUD120R9V5 TUD120MV5 TUD14DROVS TUD140R9V5 TUD140R9V5 +TXH041A4 +TXH054A4 +WD1063S3 +RXC06SS3 +TXH041A4 +TXH054A4 +RXH063S3 EXPANSION TYPE CHG TO 75 CHG TO 75 TXV-NB TXVNB CHG TO 75 CHG TO 75 TXV-NB RATINGS (COOLING) O BTUH (TOTAL) 48500 50000 50000 49000 48500 50000 50000 BTUH (SENSIBLE) 37300 38900 38500 37600 37000 38700 38300 INDOOR AIRFLOW (CFM) 1625 1625 1625 1625 1600 1600 1600 SYSTEM POWER (KW) 4.18 4.31 4.05 4.08 4.16 4.27 4.05 EER / SEER (BTUIWATT=HR.) 11.60113.25 11.60113.25 12.35114.75 12.00114.25 11.65113.50 11.70/13.50 12.35114.75 TUDUOR9115 TUYIDDRVV4 TUY100R9V4 TUY100R9V4 TUYIDDRBV4 TUYIMM4 TUY120M5 +RXC065S3 +TXH041A4 +TXH054A4 +RXCD37S3 +RXC054S3 +RXH063S3 +TXH041A4 EXPANSION TYPE TXV-NB CHG TO 75 CHG TO 75 TXV-NB TXV-NB TXV-NB CHG TO 75 RATINGS (COOLING) O BTUH (TOTAL) 48500 48000 49000 47500 47500 49000 47500 BTUH (SENSIBLE) 34500 35100 36300 34600 34300 35800 34600 INDOOR AIRFLOW (CFM) 1315 1425 1430 1430 1430 1425 1400 SYSTEM POWER (KW) 4.02 4.17 4.22 4.06 4.06 4.03 4.08 EER I SEER (BTUIWATFHR.) 12.05114.00 11.50113.25 11.60113.25 11.70114.00 11.70114.00 12.15114.50 11.65113.50 7UY12DROVS TUY12DROVS TUY120R9V5 +TXH054A4 +RXH063S3 +RXC065S3 EXAANSIONTYPE CHG TO 75 TXVLNB TXVNB RATINGS (COOLING) (D BTUH (TOTAL) 49000 49000 48000 BTUH (SENSIBLE) 36200 35600 34900 INDOOR AIRFLOW (CFM) 1425 1400 1400 SYSTEM POWER (KW) 4.17 4.00 3.98 EER / SEER (BTUIWATT-HR.) 11.75113.50 12.25114.50 12.05114.25 Notes: O Certified in accordance with A.R.I. Standard 210/240 4TTX4048-SUB-100.00 3 I J 9 • C J 0 sXWE• Mechanical Specification Options General The 4TTX4 shall be fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit must be designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities shall be matched with a wide selection of air handlers and furnace coils that are A.R.I. certified. The unit shall be UL listed. Exterior must be designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint. Corrosion and weatherproof CMBP-G30 DuratuffTm Base. Refrigerant Controls Refrigeration system controls include condenser fan and compressor contactor. High and low pressure controls are inherent to the compressor. Another standard feature is the liquid line dryer. Compressor The Climatuff" compressor features internal over temperature and pressure protector, total dipped hermetic motor and thermostatically controlled sump heater. Other features include: roto lock suction and discharge refrigeration connections, centrifugal oil pump, and low vibration and noise. The Climatuff® compressor is standard with a 10 year limited warranty. S 41ID?PJ Condenser Coil The Spine Fin TM coil shall be continuously wrapped, corrosion resistant ail alumi- num with minimum brazed joints. This coil is 5/16 inch O.D. seamless aluminum glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is pro- tected on all four sides by louvered panels and has a 10 year limited warranty. Low Ambient Cooling As manufactured, this unit has a cooling capability to 55°F. The addition of an evaporator defrost control permits operation to 40°F The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. Accessories Thermostats — Heating/Cooling (manual and automatic changeover). Sub -base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. Outdoor Thermostat — Supplemental heat outdoor ambient lockout from 46 to –10°F. ftne • A business of American Standard Companies Trane has a policy of continuous product and product data improvement and it reserves the right to change www.trane.com design and spefcations without notice. 0 T/PIINE' • TAG: C. • NOTE: All dimensions are in mminches. ELEC ERICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. LIOUID LI VALVE, RA I ORALE WIT'" 4. ITNIll' PRESSURE TAF Project Name Equipment Number Sales Office/Distributor UNITSHOULD EIC PLACED SO ROOF RUN.00C WATER DOCS NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 112'1 rRON WALL AND ALL SURROUNDING SNRUBUERY ON TWO SIDES. DINER 1. SIDES UNRESTRICTED, MODELS JBASEJ A I B I C I D I E I F G I H J 1267 946 870 152 98 219 86 4TTX4060A 4 (49-7/8) (37-1/4) (341/4) 7183� (6) (3-7/8) (85/8) (3-3/8) From Dwg. 21 D152635 Rev. 3 is' C&US © 2002 American Standard Inc. All Rights Reserved Date 4TTX4060-S U B-100.00 5 Ton Split System Cooling —1 Phase 4TTX4060A Outdoor Unit (Do 4TTX406OA1000A General Data SOUND RATING (DECIBELS) 0 0 7808 POWER CONNS. — V/PH/HZ o 208/230/1/60 MIN. BRCH. CIR. AMPACITY 39 BR. CIR. I MAX. (AMPS) 60 PROT. RTG. f MIN. (AMPS) 60 COMPRESSOR CLIMATUFF® - SCROLL NO. USED - NO. SPEEDS 1 - 1 VOLTS/PH/HZ 2081230/1/60 R.L. AMPS o - L.R. AMPS 30.1 - 158 FACTORY INSTALLED 1.4 START COMPONENTS O YES INSULATION/SOUND BLANKET YES COMPRESSOR HEAT NO OUTDOOR FAN — TYPE PROPELLER DIA. (IN.) - NO. USED 27.6-1 TYPE DRIVE - NO. SPEEDS DIRECT - 2 CFM @ 0.0 IN. W.G. 0 4400 NO. MOTORS - HP. 1 - 1/6 MOTOR SPEED R.P.M. 825 VOLTS/PH/HZ 200/230/1/60 F.L. AMPS 1.4 OUTDOOR COIL—TYPE SPINE FINT"" ROWS-F.P.I. 2-24 FACE AREA (SQ. Fr.) 26.32 TUBE SIZE (IN.) 5/16 REFRIGERANT R-41 OA (O.D. UNIT) NP CHRG. © 8/04-LB/OZ FACTORY SUPPLIED YES LINE SIZE - IN. O.D. GAS o 7/8 LINE SIZE - IN. O.D. LIQ. 0 3/8 FCCV RESTRICTOR ORIFICE SIZE 0.086 DIMENSIONS H X W X D OUTDOOR UNIT CRATED (IN.) 54 X 35.1 X 38.7 UNCRATED SEE OUTLINE DWG. WEIGHT SHIPPING (LBS.) 360 NET (LBS.) 312 NOTES: O CERTIFIED IN ACCORDANCE WITH THE UNITARY AIR -CONDITIONER EQUIPMENT CERTIFICATION PROGRAM WHICH IS BASED ON A.R.I. STANDARD 210/240. OO RATED IN ACCORDANCE WITH A.R.I. STANDARD 270. OO CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE. ONLY USE HACR CIRCUIT BREAKERS OR FUSES. O STANDARD AIR - DRY COIL - OUTDOOR OO THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT NAMEPLATE AND SERVICE INSTRUCTION. O MAX. LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR - 60 FT WITH SCROLL MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFERTO REFRIGERANT PIPING SOFTWARE PUB. NO.32-3312-01. OO THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUIT SELECTION CURRENT. O NO MEANS NO START COMPONENTSYES MEANS QUICK START KIT COMPONENTS PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER. OO RATED IN ACCORDANCE WITH A.R.I. STANDARD 270/SECTION 5.3.6. kt, • 4TTX4060A With Cooling Coils TXA042C4 TXA043C.4 TXA046C4 TXA049C4 TXA050C4 TXC042C4 TXC043C4 EXFRNSION TYPE RXA060S3 RXA061S3 RXC054S3 RXCD60S3 RXC061S3 RXC065S3 RXH063S3 LONTYPE TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB RATINGS (COOLING) O 54500 58500 57000 60000 60000 54500 58500 BTUH (TOTAL) 59500 60500 59500 59500 60500 61500 63500 BTUH (SENSIBLE) 41700 43600 41800 41700 43600 46100 48000 INDOOR AIRFLOW (CFM) 1700 1800 1700 1700 1800 2000 2000 SYSTEM POWER (KW) 5.83 5.87 5.83 5.83 5.87 5.94 6.02 EER / SEER (BTUANATTHR.) 10.20112.25 10.30/12.50 10.20/12.25 10.20112.25 10.30112.50 10.35/12.50 10.55/12.75 TXA042C4 TXA043C.4 TXA046C4 TXA049C4 TXA050C4 TXC042C4 TXC043C4 EXFRNSION TYPE CHG TO 86 CHG TO 86 CHG TO 86 CHG TO 86 CHG TO 86 CHG TO 86 CHG TO 86 RATINGS (COOLING) O CHG TO 86 CHG TO 86 CHG TO 86 CHG TO 86 CHG TO 86 BTUH (TOTAL) 54500 58500 57000 60000 60000 54500 58500 BTUH (SENSIBLE) 35200 40300 37700 42000 42000 35200 40300 INDOOR AIRFLOW (CFM) 1200 1575 1350 1675 1675 1200 1575 SYSTEM POWER (KW) 5.53 5.85 5.67 5.94 5.94 5.53 5.85 EER / SEER (BTU/WATT-HR.) 9.85/11.25 10.00/11.50 10.05111.50 10.10/11.50 10.10/11.50 9.85/11.25 10.00/11.50 • 2 4TTX4060-SUB-100.00 TXC048C4 TXCO49C4 TXC050G TXH041A4 TXH854A4 EXFRNSIONTYPE CHG TO 86 CHG TO 86 CHG TO 86 CHG TO 86 CHG TO 86 RATINGS (COOLING) O BTUH (TOTAL) 57000 60000 60000 59500 62500 BTUH (SENSIBLE) 37700 42000 42000 41300 44700 INDOOR AIRFLOW (CFM) 1350 1675 1675 1575 1700 SYSTEM POWER (KW) 5.67 5.94 5.94 5.86 6.04 EER / SEER (BTU/WATT-HR.) 10.05/11.50 10.10/11.50 10.10/11.50 10.15/11.50 10.35/11.75 4TTX4060A With Air Handlers 4TMF49A 4TEEUM 4TEP3F42A 4TEP3F48A 4TMF63A TWE042C14 TWE04BC14 EXPANSION TYPE TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB CHG TO 86 CHG TO 86 RATINGS (COOLING) O BTUH (TOTAL) 62500 63000 58500 60500 63000 58000 60500 BTUH (SENSIBLE) • 45400 45700 40500 43600 47400 40400 43800 INDOOR AIRFLOW (CFM) 1800 1800 1575 1800 2000 1575 1800 SYSTEM POWER (KW) 5.95 5.83 5.79 5.87 6.24 5.89 6.08 EER / SEER (BTU/WATT-HR.) 10.50/12.50 10.80/13.00 10.10112.00 10.30112.25 10.10112.00 9.85/11.50 9.95/11.50 Notes: O Certified in accordance with A.R.I. Standard 210/240. • 2 4TTX4060-SUB-100.00 0 • 4TTX4060A With Furnaces & Coils TUD140MV5 +RXC055S3 EXFRNSION TYPE TX1/NB RATINGS (COOLUIG) O BTUH (TOTAL) 59000 BTUH (SENSIBLE) 40800 INDOOR AIRFLOW (CFM) 1575 SYSTEM POWER (KW) 5.78 EER / SEER (BTU/WATFHR.) 10.20112.45 C J is Notes: O Certified in accordance with A.R.I. Standard 210/240. 4TTX4060-SUB-100.00 • Mechanical Specification Options General The 4TTX4 shall be fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit must be designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities shall be matched with a wide selection of air handlers and furnace coils that are A.R.I. certified. The unit shall be UL listed. Exterior must be designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint. Corrosion and weatherproof CMBP-G30 DuratuffTm Base. Refrigerant Controls Refrigeration system controls include condenser fan and compressor contactor. High and low pressure controls are inherent to the compressor. Another standard feature is the liquid line dryer. Compressor The ClimatuffO compressor features internal over temperature and pressure protector, total dipped hermetic motor and thermostatically controlled sump heater. Other features include: roto lock suction and discharge refrigeration connections, centrifugal oil pump, and low vibration and noise. The Climatuff® compressor is standard with a 10 year limited warranty. r.o* S��f:OP�V Condenser Coil The Spine Fn TM coil shall be continuously wrapped, corrosion resistant all alumi- num with minimum brazed joints. This coil is 5/16 inch O.D. seamless aluminum glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is pro- tected on all four sides by louvered panels and has a 10 year limited warranty. Low Ambient Cooling As manufactured, this unit has a cooling capability to 55°F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. Accessories Thermostats — Heating/Cooling (manual and automatic changeover). Sub -base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. Outdoor Thermostat — Supplemental heat outdoor ambient lockout from 46 to –10°F. Thane A business of American Standard Companies Trane has a policy of continuous product and product data improvement and it reserves the right to change www.trarie.com design and specifications without notice.