Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
12-0695 (SFD)
L P.O. BOX 1504 VOICE (760) 77,d6� 78-495 CALLE TAMPICO FAX (760) 777-7011 -LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT ` INSPECTIONS (760) 777-7153 r BUILDING PERMIT Date:, 10/09/12 Application Number: 112-00000695 Owner: Property Address: X53804 VIA -PA JERRY D. HORN, TRUSTEE APN: 777-220-013-227 -298942- 80725 VIA MONTECITO Application description: DWELLING - SINGLE FAMILY DETACHED LA QUINTA, CA 92253 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 653696 Contractor: ` Applicant: Architect or Engineer: FEDDERLY & ASSOCIATES 38747 NOPALES ROAD PALM DESERT, CA 92211 T (760) 773-5205 Lic. No.: 762889 � � O -------- - LICENSED CONTRACTOR'S DECLARATION - WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury that l am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect._ I have and will maintain a certificate of consent to self -insure for workers' c pensation, as provided Lis se Class: B - License No.: 762889 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. d ontractor: Date: w� I have and will maintain workers' compensation insurance, as required by- Section 3700 of the Labor - Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION - - insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier EVEREST INS Policy Number 76.0000440081 following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the.Business and Professions Code) or 3700 of the Labor Code, I shall forthwith comply with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by /J - any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: Date: (_) -1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and - - the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The - WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL . Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND - and who does the work himself'or herself through'his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or - improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT ' 1 _ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1 . Each person upon whose behalf this application is made, each person at whose request and for pursuant to the. Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, I _ 1 I am exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnity and hold harmless the City' of La Quinta,'its officers, agents and employees for any act or omission related to the work being Date: Owner: ' CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is. issued (Sec. 3097, Civ. C.). Lender's Name: - Lender's Address: LQPERMIT w performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of suchpermit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information•is correct. I agree to comply with all city and county ordinances, d state laws relating to building construction, and hereby authorize representatives this county to enter upo the above-mentioned property forinspectionpurposes. te: l 1' gnature (Applicant or Agent):�N�--� Application.Number, 12-00000695 Structure Information Construction'Type ". TYPE V, UNPROTECTED Occupancy Type ,. . . . DWELLG/LODGING/CONG <=10 Other struct info CODE EDITION 2010 # BEDROOMS 5.•00 FIRE SPRINKLERS, YES -: 1 . _ GARAGE SQ 1278.00 _FTG PATIO•SQ FTG •1350.00 NUMBER OF UNITS 1.00 ------------------------------------------------------------------ 1ST FLOOR SQUARE FOOTAGE'. 7376.00 Permit . . BUILDING PERMIT { Additional desc '. Permit Fee 2501.50 PlanCheckFee 1625.98 Issue Date . . . . Valuation 653696 Expiration Date 4/07/13 Qty Unit Charge Per Extension BASE FEE 2039.50 • 154.00 3.0000 THOU BLDG 500,001-1,000,000 462.0.0 Permit ELEC-NEW RESIDENTIAL ' Additional desc Permit Fee . . . 340.72 Plan Check Fee 85:18 Issue Date Valuation. 0 Expiration Date 4/07/13 Qty Unit Charge, Per Extension BASE FEE 15.00 7376.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 258.16 2628.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 52.56 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additioinal , desc Permit Fee . . . 15.00 'Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 4/07/13 Qty Unit Charge Per Extension - BASE FEE 15.00 Permit . . . . . MECHANICAL LQPERMIT - - Application Number 12-00000695 Permit MECHANICAL Additional desc . Permit Fee 214.50 Plan Check-Fee 53.63 Issue Date . . . . Valuation 0 Expiration Date 4/07/13 Qty Unit Charge ;Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 4.00 11.0000 EA MECH FURNACE >100K 44.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 4.00 16.5000 EA MECH B/.0 >3.-15HP/>100K-.500KBTU 66.00 10.00 6.5000 EA MECH-VENT FAN 65.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit PLUMBING Additional desc Permit Fee 247.50 Plan Check Fee 61.88 Issue Date Valuation 0 Expiration Date 4/07/13 Qty Unit Charge Per Extension BASE FEE 15.00 26.00 6..0000 EA PLB FIXTURE 156.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 3.00 7.5000 EA PLB WATER•HEATER/VENT 22.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 16.00 .7500 EA PLB GAS PIPE >=5 12.00 1.00 15.0000 EA PLB 'GAS METER 15.00 Special'Notes and Comments " 7376 SFD (6206 SF LIVING -MAIN; 1170 SF DET. GUESTHOUSE} TYPE V-B W/ FIRE SPRINKLER', R-3 OCCUPANCY. 2010 CODES. 2006-DIF. ENGINEER: REZA ASGHARPOUR. **PERMIT DOES NOT INCLUDE BLOCK WALLS,, FENCES, SWIMMING POOLS, SPA, FIRE.PIT, BBQ'S and DRIVEWAY APPROACH** Other Fees . . . . . . . ART IN PUBLIC PLACES-RES 1134.24 BLDG STDS ADMIN (SB1473) 27.00 DIF. COMMUNITY CENTERS-RES 74.00 DIF CIVIC CENTER - RES 995.00, ENERGY REVIEW FEE 162.60 DIF FIRE PROTECTION-RES 140.00 DIF LIBRARIES- RES 355.00 Application Number .. . . 12-00000695 ------------ ------------------------------------------------------ ------------------------------------------------------ Other,Fees Other•Fees . . . MULTI -SPECIES (MSHCP) FEE -------------- 1254.00 DIF PARK MAINT FAC - RES 22.00' DIF PARKS/REC - RES 892.00 STRONG MOTION :(SMI)-- RES 65.37 DIF STREET MAINT FAC -RES 67.00 , DIF TRANSPORTATION - RES 1930':00 Fee summary Charged Paid Credited Due, Permit Fee Total 3319.22 .00 .00 3319.22 Plan Check Total 1826.67 1000.00 .00 826.67 Other Fee Total 7118.21 .00 .00 7118.•21 Grand.Total 12264.10 1000.00 '.00 11264.10 LQPERMIT - a at .4 Q" (u 1 221 � � P.O. BOX 1504 Buildingc7CALLE O Address JMO i 6110 a LA QUINTA, CALIFORNIA 92 253 Owner �p/r4 � Pati jbr Mailing 7)0 ^�� Address City]- ,T_-. t `a monifb-b Zip 522 Tel. luo Address ] .14 alt'! City l maip q, State Lic. 101VIII & Classif. Arch., Engr., Designer Address T61. 17,a,1LV1 10Anary 1.1L_ D 1,�' 1,0 APPLICATION ONLY BUILDING: TYPESCONS'T P. OCC. GR , A.P. Number ! '` - 2-20 -015 Legal Description S - 22 51 IYA Project Description I -773-62bCR City �]' SFt. — No. Lic. # ` Size Sto �u�a^ /►�-iG� New Add ❑ t'liy up Mate / Q QA�m 0t9 "t q%� Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with ection 7000) f Div ion 3 of the ' ss fessions Code, and my license is i full f ce and effect. SIGNA R 12, DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds ort mproves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or, im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensa o Insurance or a certi 'ed co thereof. Sec. 3 00„Labor ode.) Policy No. yRA Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT Estimated Valuation 1: No. Dw. Alter ❑ Repair ❑ Demolition ❑ PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S. M.I. Grading Driveway Enc. Infrastructure - i jl:)i f TOTAL REMARKS G t r AMOUNT /OGIO, DO ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE oacAlla Valle Unified School District Valley _ This Box For -District Use Only : 83=733 Avenue 55;: Thermal; :CA' 92274 DEVELOPER FEES PAID (760)::398=5909 — Fax: (760)'398-1224 " AREA: :. . : - - : AMOUNT " LEVEL ONE AMOUNT: : LEVL'L TWO AMOUNT: MI'I'IGA'I'ION AMOUNT: COMMAND. AMOUNT: "DATE: � � � "RECEIPT: _ CHECK #: ' ' " "INITIALS " CERTIFICATE OF COMPLIANCE (California Education Code.17620) .. ..ProjectName: heHideaway Date: Ocf6ber.9,.2012 ' Owner's Name:: • Jerry. Horn , :: ' . _ . Phone No. 760-773-5205 Project Address: 53 -804 -Via Palacio, L•aQuinta; CA' 'Project Description: :.'New Single Family Dwelling , _. APN ..7777220-013 ::: , : Tract. #: Lot #'ss Type of Development::.: Residential ::XX! Commercial Industrial: Total Square Feet Building Area: .7;376 Certification.of Applicant/Owners:. The person signing certifies that the above information is' correct and makes this statement under ' penalty of:perjury and further represents•that he/she is.authorized to sign on behalf of the owner/developer.: Dated:..... October 9'; 2012..... Signature:...���`G.... .. ... : SCHOOL DISTRICT'S REQUIREMENTS: FOR THE ABOVE PROJECT HAVE.BEEN:OR WILL BE.SATISFIED IN ACCORDANCE WITH ONE OF THE -FOLLOWING: (CIRCLE ONE). Education Code . Gov. Code ; : ,: Project... ,Agreement Existing Not Subject to Fee 17620 65995 ' ..Approval Prior to 1/1/87 Requirement p. Number of Sq.Ft.. 7376' Pursuant to AB. 181:anyroom additions or enclosures of 500 s ft. or less are exempt from develop'er'-fee's.", Any mobile Amount per Sq.Ft. $3.20 q p -: homes being relocated within the same school district's Amount Collected .. $23603.20: jurisdiction are. exempt from developer fees. • - Building Permit Application Completed: Yes/No By: Elsa -F. Esqueda, Director: of Facilities and Maintenance 3b_ Certificate issued by Laurie.Howard; Secretary Signature: � = NOTICE OF 90 DAY PERIOD FOR PROTEST. OF FEES AND. STATEMENT OF FEES Section 66020 of the -Government Code asserted by Assembly Bill 3081, effectivejanuary 1, 1997, requires that -this District pr6vide.(1):a.written notice to the , project appellant, at the time *of payment of school fees, mitigation payment or other exactions ("Fees), " .of the 90 -day period to protest the imposition of these" Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such. Fees' or:the:validity thereof, commences with the payment ofthe fees or performance of any other . . . . . requirements as described in section 66020 of the Government code: Additionally, the amount "of the fees imposed'is as herein set forth, whether payable at this . N time, or in whole or in. part: prior to issuance: of a. Certificate of Occupancy.- As.in.the latter, the 90 days.starts on the date hereof... This Certificate of Compliance is valid for thirty: (30) days from the date:of:issuance. Extension will be granted only for good cause, as determined by the School District, and up ' to three (3) such extensions may be granted. NtV:c%litydocsldevfees/certificate of -compliance form updated :3:, Ow' :::11/2010 Lawyers Title - • ' RECORDING REQUESTED BY ` Lawyers Title -'IE WHEN RECORDED MAIL THIS DOCUMENT E AND TAX STATEMENTS TO: Jerry. D. Horn,' Trustee ' 80725 Via Monticeto T , La-Quinta, CA 92253 , APN: 777-220-013-9 Escrow No: PDL10965-LT139-CM Title No: 612680184. Space above this line for Recorder's use Tom-020-IIoD GRANT DEED' THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX IS $1210.00 IM computed on full value of property conveyed = ® City of La Quinta FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Stephen J. Harder and Cynthia A. Harder, as Trustees•of the Cynthia A. Harder Trust dated May 10,- 2007 as to an undivided 509/o interest and Stephen J. Harder, Trustee of the Stephen J.'Harder Trust ` dated May 10, 2007 as to an undivided 500/a interest , hereby GRANT(S) to Jerry D. Horn, trustee of the Jerry D. Horn Revocable Deed of.Trust, established - November 4, 1999 as amended and restated November 13, 2006 • r the following described real property in the City of La Quinta County of Riverside, State of CALIFORNIA: , For legal description of the real property herein,'see Exhibit A attached hereto and made a part hereof.. ` z . Commonly known as: 53804 Vacant Land APN: 777-220-013 / 53804 Via Palacio, La Quinta, CA 92253 ; t Dated: January 23, 2012 ' i - STATE OF CALI�"NIA ` COUNV OF ss: the n is A. H rder T ust dated May 10,'2007 On before me ►� or. , a Notary Public, y.:; ephen ] Harder, Tru ee, (here insert name a itle of the officer) personally appeared . dfl T• - 3 , tt�-f�ia�, Q- By: Cynt is A Harder, Trustee who proved tom n the basis of sati ctory evidence - to be .the persot�whose namie ar subscribed to the ep, n J. Har er Tryst dated May 10,2007- the 0, 2007 - the _wit instrument and acknowledged to me he/! he execute the same In his 1 th authoriz capacity(�ej, and that by his her By: Stephen J. Harder, Trustee signatureo on the instrument the person or the entity upon behalf of which the person acted, . s executed the instrument.' I certify un r ENALTY OF PERJURY under, the laws of CARiN L. MOON ��: the State° Cayifornia that the foregoing paragraph is Commission ,v 1910901 = i Notary Public - California,' a true and co .rect. , Riverside County WITNESS y: ha n and official seal. Comm. Ex fires Nov 19, 20111, , Signature - f (This area for notary'stamp) MAIL TAX STATEMENTS AS DIRECTED ABOVE 1 /� e 67 HIDEAWAY .{ t OWNERS ASSOCIATION September 10, 2012' R Mr. and Mrs. Jerry Horn wo 80725Via Montecito , La Quinta; CA 92253 : RE: Horn/Lot 227 at 53804 Via Palacio r ,, Final Working Drawings Dear Mr. and Mrs. Horn. The Hideaway Design Review Committee (DRC) reviewed and approved' the' Final Working. Drawing, submittal for your home on Via Palacio subject to the :following comments being T addressed prior to your request for Setback Observation: 1. The side yard sconces must meei the current guideline standards with -.regard to heights and appropriate wattages. :.In addition, seeded or frosted glass must be used (the cut sheet shows '., 'Specifies clear glass). 2. The backflow preventer must be located out of site and fully screened for public view: ,. Please clarify the .finish of the landscape .l.ighti.ng fixtures prior to installation. '.['his can be done a 'Part of y6 it calor and .material review in the held during construction. F Please contact Brook Marshall at (760) 219-8057 or by email. at Brook(Adc.rr.c0m. with any - questions. Sincerely, , Hideaw(v Design Review Committee cc:: Lance I-edderlv C, rerry 'rarsi tan h r " ierryl-lorn�rytic.n'.cenr _ • s DRC File . • 80955 Avenue 52 La Quinta, CA 92253 P: 760 39.3-5210 F: 760 398-5788 ' PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CRIES OF: BANNING BEAUMONT CALIMESA,' ` CANYON LAKE C OAC H E LLA DESERT HOT SPRINGS EASTVALE �- INDIAN WELLS INDIO , LAKE ELSINORE LA QUINTA t MENIFEE MORENO VALLEY PALM DESERT PERRIS RANCHO MIRAGE RuBIDOUx CSD SAN JACINTO r TEMECULA WILDOMAR i BOARD'OF SUPERVISORS: BOB BUSTER DISTRICT 1 . JOHN TAVAGLIONE DISTRICT 2 JEFF STONE - DISTRICT 3 JOHN BENOIT DISTRICT 4', MARION ASHLEY DISTRICT 5 RIVERSIDE COUNTY FIRE DEPARTMENT ' V. • - IN COOPERATION WITH THE CALIFORNIA, DEPARTMENT OF FORESTRY AND FIRE PROTECTION .77-933 Las Montanas Rd., Ste. #201,•Palm Desert, CA 92211-4131. Phone (760) 863-8886 . Fax (760) 863-7072 www.rvcfire.org July 9, 2012 -, Dave Williams 81-595 Rancho Santa Dr. La Quinta, CA n '_ Re: Residential Fire Sprinkler.Plan Review LQ -12 -RS -044 Horn Residence 53-804 Via Palacio The Hideaway La Quinta, CA The. sprinkler plans you submitted for the above referenced project have'been reviewed by Riverside County Fire Department Planning'& Engineering personnel and, are approved with the following conditions: - A minimum of three spare fire sprinklers of each type and temperature rating along with a sprinkler wrench should be located in a spare head cabinet at the system riser or other approved location. Permanently marked identification signs shall be attached to all`control valves. ` The completed Contractor's Material and Test Certificate for Aboveground Piping shall be provided to the fire inspector prior to a final inspection. A typical certificate is shown in Figure 10.10.1 NFPA13. A warning, sign, with minimum '/'inch letters, shall be.affixed adjacent to the main shutoff valve and shall state the following: • , WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a ,fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protections specialist. DO NOT remove this sign. r The following inspections/tests are required to be witnessed by the Fire.Department Planning -. Division staff: (a) Fire Riser Flush: Prior to connection of above ground sprinkler'system a flush shall be witnessed. t (b) Overhead'Rough and Hydro static test: All piping shall'be visible and pumped at normal operating pressure. ` i (,c) Final inspection. The Fire Department job card, approved plans and conditions letter must be at the job site or NO inspection will,be performed. Applicant/installer shall be responsible to contact,the Fire Department to schedule'inspection(s) a minimum of 72 hours prior t0he requested inspection " date. :. *SEP I:1 2012 `.. ay Bin # City of La Quinta Building 8T Safety Division ' P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253. (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: 6l�GtGIl,vcRlil�{�l Owner'sName� fmu A. P. Number: `��'� - 2 ^ (�` ?J Address:,Z�017ea VL . MM+(fG1TVk Legal Description: Sl. Mi & Lr i5M (6 City, ST, Zip: LL &Ul vi+z1 t c -A, Contractor: eyl vf}7ijGLL .� Telephone: -1 Q6 " 02 - `I'"/ Address: 3!K-7Y-oa-e` Project Description: City, ST, Zip: 12 Z Telephone -.-I- State Lic. # : `� �/ City Lic. Arch., Engr., Designer: Address: 5-74� City, ST, Zip: '� State Lic. #: Name of Contact Person: �J\ CJ l -t° OI.V� _� Construction n TY Pe: Occupancy:e Project type circle one ew Add n Alter Repair Demo Sq. Ft.: , ?j'1 # Stories: # Units: Telephone # of Contact Person: J(00- -1-15- 970G h t/ 0-J- I Estimated Value of Project: 4--3, . 3 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets a Plan Check submitted tem Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Cales. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up , S.M.I. H.O.A. Appal^ �, V \\\\ Plans resubmitted Grading ` IN Ho 3E:� 13 �� i"� Review, ready for correctio /issue I 13 Developer Impact Fee U' Planning A, p� ovate t ` Galled Contact Person 'Q ` A.I.P.P. Pub. Wks.ritppr School FeA Date of permit issue G� Total Permit Fees �� �! Electronically Filed by -Tim Sca1 Scott and Authenticated at CCERTS'.com - 1/10/2013; " Electronically Signed�at CalCERTS.Com by Robin -Lever (Fedderly"&'Associates)-1/10/2013 •mac PERFORMANCE CERTIFICATE: Residential ~" Part 1 of 5 CF -1 R Project Name Hom Guest House Building Type m Single Family ❑ Addition Alone ❑ Multi Family, ❑ Existing+ Addition/Alteration Date 1/1012013 Project Address Lot. 227 -The Hideaway La Quinta California Energy Climate Zone CA! Climate Zone 15 , Total Cond. Floor Area ` 1,102 Addition. n/a # of Stories, 1 FIELD INSPECTION ENERGY CHECKLIST :.. ❑ Yes 0 No • HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special - Construction . Type Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic ' R-38 1 L02 - Radiant Barrier New Wall Wood Framed R-21 1,399. 1 New B Slab Unheated Slab-on-Grade1, _02 'L/A A New �---. «OtArt I Y DEPT. Z, If_f-rJUVLU - _ ION - j FENESTRATION.' U- Exterior. , Orientation . Area(ft) VFactor SHGC Overhang Sidefins Shades Status ' Front (N) - 46.4 fib: ; 0.390 0.28 none none Bug Screen New Leff{E) 31.2 "-0.390.,0 - 028 none.none BugSeregp New Rear (S) 164.7 0390" '0 28MR hone�� none Bug Screen New P .. _. Right A9_" 10.64 090; 02vx ohne �e.. Bug Screen •Y'Rk %' •;bg ,�A9 .� O' •`n.,.3'+`K>» i'^•'(r iea X• Y E 4 k the k. _...�^k'�i. .•^'r }f. _ .. p�� . gym .."�'r Y .d.- � .: r'fi �. -. i ..•, ^.5. ti-t�� �•r � /T g o •1 p .. ,APIN'g a V 4. 'HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min.-.Eff Thermostat. Status 1 Central Furnace 80% AFUE • Split Air Conditioner 16.5 SEER Setback New , HVAC DISTRIBUTION Duct Location Heating cooling Duct Location R -Value •' Status HVAC 1 Ducted Ducted . Attic, Ceiling Ins, vented 8.0 New WATER HEATING a , Ot . Type Gallons Min: Eff Distribution Status- ' 1 Large Gas . 100 0.80 All Pipes Ins New Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2013-01-09713:54:06 ID: Page 1 of 5 Reg:"212-N0049628B-000000000-0000 Registration Date/Time: 2012/09/07 12:44:33 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/10/2013 Electronically Signed at CalCERTS.com by`Robin Lever (Fedderly & Associates) 1/10/2013 ' PERFORMANCE CERTIFICATE: Residential Part' 2 of 5 CF -1 R Project Name Building Type ® Single Family' ❑ Addition Alone Date • _ Horn Guest House ❑ Multi Family ❑ Existing+ Addition/Alteration I 1/10/2013 SPECIAL -FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items,specified in this checklist. These items require special written justification and documentation,'and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. : The DHW System Bradford White #114-1-100TON is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. The Roof R-38 Roof(R.38.2x 12.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. low77, h .i4ti.€' � %..'. HERS REQUIREDVERI�FICATION: ffi rt. Items m thssect(on�requtrefieldtestmgandJor�enficaUon byacert(fied'NERSRater The mspectorrimusf receive a com leted CF=4PI form for eac of the' measures listed below for final td be givier. The Cooling System .Carrier.24APA760/58PH'110 includes credit fora 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct, Condenser: >-., § • t The HVAC.System HVAC hiricorporates HERS Verified Refrigerant Charge or a Charge'Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria'. r t r - Ener Pro 5.1 by Ene ySoft User Number: 6712 RunCode: 2013-01-09713:54:06 ID: Page 2 of 5 Reg:•212-N0049628B-000000000-0000 Registration Date/Time: 2012/09/07 12:44:33 HERS Provider:lCa10ERTS,.Inc Electronically Filed'by Tim rScott �and Authenticated at CalCERTS'com i/l0/2013 4�'r # ^yr ,' f•' ' Electronically Signed at Ca10ERTS.com by.Robin Lever (F.edderly &Associates) 1/10/2013''` 'PERFORMANCE CERTIFICATE:: Residential . • Part 3, of 5 CF -1 R Project Name : Building Type m Single Family • ❑ Addition Alone Date HOm Guest House f` ' ❑ Multi 'Family, ❑ Existing+ Addition/Alteration 1/10/2013 ANNUAL ENERGY USE SUMMARY ` - • Standard Proposed Margin TDV kBtu/ft2- r Space°Heating 4.89 • 3.47 1.42 - %ace Cooling 67.34 ;47.65 19.69 Fans -13.38 15.18. -1.81 411' Domestic Hot Water, • 23.84 13.32 10.52 Pumps 0.00.. ` 70:00 0.00 Totals 109.46 79.63 29.83 5 Percent Better Than -Standard: 27.3 i BUILDING COMPLIES,.- HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (IV) 0deg Ezt: Walls/Roof Wall Area ` ;. Area Number of Dwelling Units: ` 1.00 (N) -.: 403 46 Fuel'Available 8t Site: NsturarGas •, (E) 471', Raised i Floor Area: 0 (s) r 403 165 Slab on Grade Area: 1,102, r AM '4 106 .. , Average Ceiling Height: , ' 11.5 Roof * 1;102 _ + ; • 0 Fenestration Average.`U Factor: 0'39 TOTAL: ' 349 _ t - Avera a SHb. 0.29 ' Fenestration/CFA Ratio: 31.6 i _. ._ REMARKS..'' - L r ' t . ,'•�.-�Y Y x ^ f C 2. _' •P : Xc'C"x'#•i I,. t �A• STATEMENTt OF COMPLIANCE Thin certificate of'compliance li§ts�the building features and specifications needed to comply with Title 24; Parts`Y,1the Administrative Regulations and Part 6 the ` Efficiency Standards of -the California Code of Regulations. The documentation author hereby certifies, that the documentation is accurate and complete._ ; Documentation Author , t Company Scott Design and Title 24, Inc, '/' t > +1/1012013 Address '" , 77-085 Michigan Drive Name, Tim Scott Cit /Stateiz • Palm Desert, Ca 92211. Phone (760) 200-4780 SignedDate The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets,"with the'specifications,'and with any other calculations submitted with this permit application,•and recognizes.that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require ,installer testing and certification and field verification'by:an approved HERS rater. Designer or Owner -(per,Business & Professions Code) Company Fedderiy and Associates Address 38-747 Nopales Road Name Fedderly and Associates - { . City/State/Zip, Palm Desert, Ca 92253 Phone (760) 773-0875 a Signed License #-:." '' Date' Ener Pro 5.1 by. Ener Soft . User Number. 6712 RunCode: 2013-01-09T13:54:06 ID: Pa - e 3 of 5 .-'Reg: 212=N0049628B-000000.000-0000•Registration Date/Time": 2012/09/67 12:44:33 HERS Provider: CaFCERTS, Inc Electronically Filed by Tim Scott and Authenticated at'Ca10ERTS.com - 1/10/2013 Electronically Signed at CalCERTS.com by Robin Lever (Fedderly•& Associates) 1/10/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name . ,- Horn Guest House Building Type 'm Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/10/2013 OPAQUE SURFACE DETAILS Surface U- I Insulation Joint Appendix ,Type Area Factor -C-a-v-it-y Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,102 0.026 R-38 0 0 New 4.2.1-A9 Guest Bedroom Wall 357 0.069 R-21 0 - 90 New 4.3.1-A6 Guest Bedroom Wall 440 0.069 R-21 90 90 New 4.3.1-A6 Guest Bedroom Wall 238 ' 0.069 R-21.. 1801 90 New 14.3.1-A6 Guest Bedroom Wall 365 0.069 R-21 ' 270 90 New 4.3.1-A6 Guest Bedroom Slab 1,006 0.730 None 0 180 New 4.4.7-A1 Guest Bedroom Slab 96 0.730 None 0 .180 New, 4.4.7-A 1 Guest Bedroom FENESTRATION SURFACE DETAILS ° ID Type Area LI -Factor' SHGC Azm Status . Glazing Type Location/Comments 1 Window 24.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom 2- Window 4.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom '3. Window' 4.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom 4.. Window. 4.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom 5 Window .10.4 0.390 NFRC:.; :x0.28: ,NFRC _• 0 New Dual non Metal Tinted Guest Bedroom 6 Window X1.0.4 0.390 NFRC ,r 0.28 ,NFRC ,• 90 �Guest Bedroom 7 Window' 010.4 0.390 NFRC x'0.28'NFRC14, z" 90 New: >-, Dual non`Metal,Tinted ?A. '10: Guest Bedroom. 8 ,endow 10 4 b:39Q,'NFRCX 0.28 NFRC t•! . 90 New,'"Dual non,,'ll9etal7inted �; ; . Guest Bedroom • .:• 9 Window 72;`0 X0.390, NFRC 0.28 NFRC t 180 New,,; ' Dual non M6tal Tinted _ Guest.Bedroom„ 10 _ _ .... Window _ 92.7 1, 0:390, NFRCk-40.28 NFRC, 4180 >New Dual non'119e61 TinCed;, GuesC edrooin` -.•. _... 11 s, Windows 1;:'t 24:0 .00:390 NFRC � **A 8. NFRCg : 276. Newt""° Dual.non"Metal TintedXf`� Guesf;Bedroom �' 12 Window • "-"10.4 0:390 NFRC - 0:28 NFRC - ` = ^270 New" Dual. non `Metal Tinted ` Guest Bedroom 13 Window . 72.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Guest Bedroom . (1) LI -Factor Type: _: 1116-A'= Default Table from Standards, NFRC =Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Ove hang Left Fin Right Fin Exterior Shade Type SHGC Hat Wd Len HqA LExt RExt Dist Len H t Dist Len H qA 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 y 7 Bug Screen 0.76 8 Bug Screen0.76 s 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen' 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 Ener Pro 5.1 by EnergySoft User Number. 6712 RunCode: 2013-01-09713:54:06 ID: Page 4 of 5 Reg: 212-N0049628B7.000000000-0000 Registration Date/Time: 2012/09/07 12:44:33 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/10/2013' El,pctronically Siqned at Ca10ERTS.com by Robin Lever'(Fedderly & Associates) 1/10/2013• CERTIFICATE OF COMPLIANCE:. Residential Part 5 of 5 CF -1 R Project Name Hom Guest House - L Building Type © Single Family ❑ Addition Alone ❑ Multi Family, ❑ Existing+ Addition/Alteration Date - 1/10/2013 BUILDING ZONE INFORMATION Floor Area ft System Name Zone Name New .Existing Altered Removed Volume Year Built HVAC 1 `. Guest Bedroom 1,102 ' 12,673 L _Totals 1,102 0 0 "0 HVAC SYSTEMS` System Name:. ` Qt �'.....--Heating Type ' Min. Eff:. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 - 1 l ;Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New w �.'ri3«j �A �•`tx• .,'+ry "+8 ,:.'ilial 'i w<{^G& .V :�< `R' M' 1 ;A - 4h - L •. z.?'f:�v�nx--a+SXL. —.Tme. '-.SQA ft, ON ,s} :: to k HVAC�DISTRIBUTION�.;�� �:r,, �.. � :�� .,r � ��,`� �' .,. �:�� "M ' 5 $ F..m Pte'$ Za 3 i" . .. '• %ri 3E MT Ducts Ducts ` Sy stem Name «�� <Heatin "'Coolm "' ' _.DuctLocation €. R Value 'Tested? Status HVAC 1:' Ducted!:_ Ducted• .. Attic, Ceiling Ins, vented 8.0 m New ❑ WATER HEATING SYSTEMS i ! S stem Name QtV., Type Distribution _ Rated Input Btuh Tank Cap. al Energy Factor or RE ,Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford white #M -I-1007 1 Large Gas All Pipes Ins ' 85,000 100 0.80 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING • Control • . Hot Water Piping Length ft Q,� — .� _ '. S stem Name Pipe Len th Pipe Diameter Insul. . Thick. Qty. HP Plenum Outside Buried Ener Pro 5.1 by Ener Soft User Number., 6712 RunCode: 2013-01-09713:54:06 ID: Page 5 of 5 Reg:,212'-N0049628B-000000000-0000 Registration-Date/Time: 2012/09/07 12:44:33 HERS Provider: Ca10ERTS, Inc ' • BUILDING ENERGY ANALYSIS REPORT PROJECT: Horn Guests House Lot 227 -The Hideaway • La Quinta, Ca 92253 Project Designer: •� •� Fedderly and Associates . , CITY OF LA 38-747 Nopales Road QuiNTA BUILDING & SAFETY DEPT. Palm Desert, Ca 92253 773-0875 APPROVED. (760) • FOR CONSTRUCTION - DA f3 i3 IeY 1 • Report Prepared b S, Jon Scott,C0 �V Scott Design and Title 24, 77-085 Michigan Drive - Palm Desert, Ca 92211 (760) 200-4780 - Job Number: JAN 11 2013.. - Date: 1/9/201-3 , The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. ; - - This program developed by EnergySoft, LLC — www.energysoft.com. \ EnergyPro 5.1 by.EnergySoft User Number: 6712 RunCode: 2013-01-09713:54:06 - ID: TABLE OF CONTENTS Cover Page r 1 Table of Contents .2. Form CF -1 R Certificate of Compliance 3 Form, MF -1 R Mandatory Measures Summary 8 HVAC System Heating! and Cooling Loads Summary 11 Room Load Summary 12 - Room Heating Peak Loads 13 Room Cooling Peak Loads f 14 EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 6712 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Horn Guest House Building Type o Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/9/2013 Project Address Lot 227 -The Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,102 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 1,102 Radiant Barrier New Wall Wood Framed R-21 1,399 New Slab Unheated Slab -on -Grade None 1,102 Perim = 152' New. FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Front (N) 46.4 0.390 0.28 none none Bug Screen New Left (E) 31.2 0.390 0.28 none none Bug Screen New Rear (S) 164.7 0.390 0.28 none none Bug Screen New Right (W) 106.4 0.390 0.28 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80 % AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Large Gas 100 0.80 All Pipes Ins New EnergyPro 5.1 by EnergySoft User Number 6712 RunCode: 2013-01-09713:54:06 ID: Page 3 of 15 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name - Horn Guest House Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/9/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used,with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special •ustification and documentation submitted. The DHW System Bradford White #M-1-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow re uirements and fan watt draw reuirements in Residential Appendix R43.3 must be met. The Roof R-38 Roof(R.38.2x 12.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION - Items in this section require field testing and/or verification.by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24APA760/58PH'110 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. rE=neP=ro5.1 EnergySoft User Number., 6712 RunCode: 2013-01-09713:54:06 ID: Page 4 of 15 PERFORMANCE CERTIFICATE: Residential Part 3 of.5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date Hom Guest House ❑ Multi Family ❑ Existing+ Addition/Alteration 1/9/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 4.89 3.47 1.42 Space Cooling 67.34 47.65 19.69 Fans 13.38 15.18 -1.81 Domestic Hot Water 23.84 13.32 10.52 Pumps 0.00. o:o0 0.00 Totals 109.46 79.63 29.83 Percent Better Than Standard: 27.3% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building,Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 403 46 Fuel Available at Site: Natural Gas (E) 471 31 Raised Floor Area: 0 (S) 403 165 Slab on Grade Area: 1,102 (LM 471 106 Average Ceiling Height: 11.5 Roof 1,102 0 Fenestration Average U-Factor: 0.39 TOTAL: 349 Average SHGC: 0.28 Fenestration/CFA Ratio: 31.6% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation. is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, IA12013 Address . 77-085 Michigan Drive Name Jon Scott Q City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Fedderly and Associates Address 38-747 Nopales Road Name Fedderly and Associates City/State/Zip Palm Desert, Ca 92253 Phone (760), 773-0875 Signed License # Date EnerqvPro 5.1 by EnemySoft user Number- 6712 RunCode: 2013-01-09713:54:06 ID: Page 5 of 15 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R Project Name Horn Guest House Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/9/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,102 0.026 R-38 0 0 New 4.2.1-A9 Guest Bedroom Wall 357 0.069 R-21 0 90 New 4.3.1-A6 Guest Bedroom Wall 440 0.069 R-21 90 90 New 4.3.1-A6 Guest Bedroom Wall 238 0.069 R-21 180 90 New 4.3.1-A6 Guest Bedroom Wall 365 0.069 R-21 270 90 New 4.3.1-A6 Guest Bedroom Slab 1,006 0.730 None 0 180 New 4.4.7-A1 Guest Bedroom Slab 96 0.730 None 0 180 New 4.4.7-A1 Guest Bedroom FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Window 24.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom 2 Window 4.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom 3 Window 4.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom 4 Window 4.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom 5 Window 10.4 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom 6 Window 10.4 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Guest Bedroom 7 Window 10.4 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Guest Bedroom 8 Window 10.4 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Guest Bedroom 9 Window 72.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Guest Bedroom 10 Window 92.7 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Guest Bedroom 11 Window 24.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Guest Bedroom 12 Window 10.4 0.390 1 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Guest Bedroom 13 Window 72.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Guest Bedroom (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC Hat Wd Ove hanq Left Fin Rant Fin Len H t LExt RExt Dist Len Hat Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 EnergyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-01-09713:54:06 ID: Page 6 of 15 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Horn Guest House Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/9/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC 1 Guest Bedroom 1,102 12,673 Totals 1,1021 01 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford White W-1-100TI 1 Large Gas All Pipes Ins 85,000 100 0.80 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ff c 0 i� U) Q -System Name Pipe Length Pipe Diameter Insul. Thick. Qty. FHP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-01-09713:54:06 ID: Pae 7 of 15 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1R Project Name Horn Guest House Date 1/9/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summaryshall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: - 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -613 Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when thei installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f). Air retarding wrap is tested labeled and installed according to ASTM Ell 677-95(2000) when specified on the CF -1 R Form. §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no areater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. . §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §1113(c)5: §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or coolin ' loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Heating s stems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minima_ I standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. - .§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. - ' §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 15O(e)3A: Insulation is pr6tected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes_ a vapor retardant or is enclosed entirely in ' conditioned space. ' 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2013-01-09713:54:06 ID: Page 8 of 15 a MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Horn Guest House 1 1/9/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot li ht. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined as specified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-01-09T13:54:06 ID: Page 9 of 15 MANDATORY MEASURES SUMMARY: Residential Pa e 3 of 3 MF -1 R Project Name Date Horn Guest House 1/9/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119.' EXCEPTION 2: Permanently installed. low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or' other. nationally recognized testing/rating laboratory; and have a label that certifies the.lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals•when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or. more dwelling units, entrances, balconies, and porches, which are permanently mounted to a`residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override'or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl, to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. I §150(k)14: Internally illuminated, address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l 5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable -requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119: r . a r EnergyPro 5.1 by EnergySoR 'User Number: 6712 RunCode: 2013-01-09713:54:06 ID: Page 10 of 15 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Horn Guest House Date 1/9/2013 System Name HVAC 1 Floor Area 1,102 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 672 15,190 Return Vented Lighting o Return Air Ducts 877 Return Fan o Ventilation 001 Supply Fan 0 Supply Air Ducts 877 TOTAL SYSTEM LOAD 1 16,944 COIL HTG. Latent CFM 888 353 - 0 0 888 PEAK Heating System Sensible Output per System 110,000 19,062 Total Output Btuh 110,000 Output Btuh/s ft 99.8 937 Cooling System . 0 Output per System 59,000 0 Total Output Btuh 59,000 0 Total Output ons 4.9 937 Total Output Btuh/s ft 53.5 Total Output s ft/Ton 224.1 1 20,936 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24APA760/58PH'110 46,976 Total Adjusted System Output 1 46,976 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 4,002 110,000 4,002 1 110,000 Aug 3 PM Jan 1 AM Airflow cfm/s ft 1.81 Airflow cfm/Ton 406.8 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 cfm Supply Fan 2,000 cfm 70 OF dig 70 OF 121 OF Heating Coil 4 121 OF ._............... _.— Room WE 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 78/63°F 78/63°F 56/55°F Outside Air Ar 0 cfm Supply Fan Cooling Coil57 / 55 OF _ .............. ._.......... _.w .. 2,000 cfm 43.9% ROOM IM 78163 OF - 78/ 63 OF EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode. 2013-01-09T13:54:06 ID: Page 11 of 15 ROOM LOAD SUMMARY Project Name Date Horn Guest House 1/9/2013 System Name Floor Area HVAC 1 1,102 ROOM LOAD SUMMARY ROOM COOLING PEAK . COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible Latent CFM Sensible Guest Bedroom Guest Bedroom I 1 I 6i2l 15,1901 888 6721 151901 888 3531 19,062 PAGE TOTAL TOTAL ' Total includes ventilation load for zonal systems. Enem yPro 5.1 by Ene Soft User Number: 6712 RunCode: 2013-01-09T13:54:06 672 15,190 888 3.531 19,062 672 15,190 888 353 19,062 ROOM HEATING PEAK LOADS Project Name Horn Guest House Date 119/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Bedroom Floor Area 1,102.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction. Area 1,102.0 X 1,399.3 X 348.7 X perim = 152.0 X U -Value AT *F 0.0260 X 44 0.0690 X 44 0.3900 X 44 0.7300 X 44 X X X X X X X X X X X X X, .. X X X X X X X X X X X X X X another room Page Total 11.50 X 0.272 / 60 X Height ACH AT Btu/hr = 1,261 = 4,248 = 5,984 = 4,882 = = = - = = = - - = - - _ _ _ = - = _ _ _ - = _ _ = 16,375 44 R-38 Roof(R.38.2x 12.16) R-21 Wall -.(W.21.2x6.16) Dual non Metal Tinted Slab -On -Grade - X X X X X X X X X X X X i X X : X X X X X X X X X X X X X through an interior surface to X 1,102 X Area Ceiling Items shown with an asterisk (•) denote conduction Infiltration:[ 1.00 X F 1.064 Schedule Air Sensible Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 19,062 EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2013-01-09T13:54:06 ID: Page 13 of 15 RESIDENTIAL ROOM COOLING LOAD SUMMARY X X X X X X X X X Project Name X X X X X X X X X 56.0 Date Horn Guest House 0.0690 23.0 1/9/2013 ROOM INFORMATION 0.0690 DESIGN CONDITIONS 1,001 Room Name Guest Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,102.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF 18.2 10.4 34.8 0.0 0.0 O a ue Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x12.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall -(W.21.2x6.16) R-21 Wall (W..21.2x6.16) 1,102.0 356.6 X X X X X X X X X 0.0260 X X X X X X X X X 56.0 = = = = = = = = = 1,605 0.0690 23.0 566 439.8 238.3 0.0690 33.0 1,001 0.0690 26.0 428 364.6 0.0690 33.0 830 t 0.0 0.0 18.2 10.4 34.8 18.2 10.4 34.8 0.0 0.0 18.2 10.4 34.8 18.2 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF J-1 J-1 J-1 J-1 J-1 J-1 J-1 J-1 J-1 (N) (N) (N) (N) (N) (E) (E) (E) (S) 0.0 0.0 0.0 X X X X X X X X X 18.2 + + + + + + + + + 24.0 X X X X X X X X X 18.2 = = = = = = = = = 18.2 4.0 18.2 18.2 4.0 18.2 0.0 18.2 4.0 18.2 0.0 18.2 10.4 18.2 0.0 0.0 18.2 10.4 34.8 18.2 10.4 34.8 0.0 0.0 18.2 10.4 34.8 18.2 72.0 18.3 Page Total L 4,4301 /hr 437 73 73 73 189 362 362 362 1,314 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.87 X 60.30 X 34 = 1,889 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,190 Latent Gain Btu/hr .Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.87 X 60.30 X 0.00276 = 688 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 888 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Horn Guest House _ 1/9/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Bedroom Outdoor Dry Bulb Temperature 112 °F Floor Area' 1,102.0 ft' Outdoor Wet Bulb Temperature p 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X _ X X = X X = X X _ X X _ X X - Page Total o Items. shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded. Fenestration Orientation Area GLF Area GLF Btu/hr J-1 (S) 0.0 X 18.2 + 92.7 X 18.3 = 1,692 J-1 (VV) 0.0 X 18.2 + 24.0 X 34.8 = 836 J-1 0.0 X 18.2 + 10.4 X 34.8 = 362 J-1 W 0.0 X 18.2 + 72.0 X 34.8 = 2,507 X + X = X + •X = X + X = X + X = X I + X = Page Total 5,397 Internal Gain Btu/hr Occupants 1.0 Occupants. X 230 Btuh/occ. = 0 23 Equipment 0.0 Dwelling Unit X 1,600 Btu 0 Infiltration: 1:064 X 0.87 X 60.30 X 34 = 1,889 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,190 Latent Gain Btu/hr Occupants t0 Occupants X 240 Btuh/occ. _ 200 Infiltration: 4,771 X 0:87 X 60.30 X - 0.00276 = 688 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 888 EnerovPro 5.1 by EneroySoft User Number: 6712 RunCode: 2013-01-09713:54:06 ID: Page 15 of 15 A ' Energ Pro 5.1 7y- Energ Soft User Number: 6712 RunCode: 2012=09-04712:33:58 ID: r ' - :BUILDING 'ENERGY ANALYSIS REPORT' Y _ - PROJECT:` ' Horn Residence Lot 227 -The Hideaway- 'La Quinta, Ca 92253 t Project Designer: Fedderly a; � � - � r. M � y - i . ' 1 �j.� f � , .. , � �, _ �. f � , .. _ PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Horn Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/4/2012 Project Address Lot 227 -The Hideaway -La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,547 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features (see Part 2 of 5) Status Roof Wood Framed Attic R-38 6,547 Radiant Barrier New Wall Wood Framed R-21 3,529 New Slab Unheated Slab -on -Grade None 6,550 Perim = 563' New Door Opaque Door None 48 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (N) 260.0 0.390 0.28 none none Bug Screen New Front (NE) • 11.3 0.390 0.28 4.0 none Bug Screen New Front (NE) 48.0 0.390 0.28 6.0 none Bug Screen New Front (NE) 11.3 0.390 0.28 none none Bug Screen New Left (SE) 129.0 0.390 0.28 none none Bug Screen New Rear (SM 125.0 0.390 0.28 10.0 none Bug Screen New Rear (SW) 64.0 0.390 0.28 2.0 none Bug Screen New Rear(SW) 11.3 0.390 0.28 4.0 none Bug Screen New Rear (SW) 48.0 0.390 0.28 none none Bug Screen New Right (NM 14.0 0.390 0.28 6.0 none Bug Screen New Right (NVV) 15.0 0.390 0.28 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot .. Type Gallons Min. Eff Distribution Status 1 Large Gas 100 0.80 All Pipes Ins New Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-04712:33:58 ID: Page 3 of 32 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Horn Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/4/2012 Project Address Lot 227-The Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. FloorArea 6,547 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features (see Part 2 of 5) Status FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status Front (N) 240.0 0.390 0.28 2.0 none Bug Screen New Left (E) 160.0 0.390 0.28 2.0 none Bug Screen New Rear (S) 600.0 0.390 0.28 16.0 none Bug Screen New Rear (SVV) 110.0 0.390 0.28 6.0 none Bug Screen New Right (Vlg 246.0 0.390 0.28 none none Bug Screen New Front (N) 63.0 0.390 0.28 6.0 none Bug Screen New Left (E) 19.5 0.390 0.28 6.0 none Bug Screen New Left (E) 119.7 0.390 0.28 none none Bug Screen New Rear (S) 166.5 0.390 0.28 none none Bug Screen New Right (VV) 150.0 0.390 0.28 20.0 none Bug Screen New Rear (S) 80.0 0.390 0.28 4.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff . Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Energ Pro 5.1 by Ener Soft User Number.. 6712 RunCode: 2012-09-04712:33:58 ID: Page 4 of 32 PERFORMANCE CERTIFICATE: Residential (Part -2 of 5) 'CF -1 R Project Name Horn Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/4/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford White #M-I-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design -Verify Thermal Mass: 1,246.0 ft2 Covered Slab Floor, 3.500" thick at Master Bedroom HIGH MASS Design - Verify Thermal Mass: 210.0 ft2 Exposed Slab Floor, 3.500" thick at Master Bedroom HIGH MASS Design - Verify Thermal Mass: 816.0112 Covered Slab Floor, 3.500" thick at Office Workout Bedroom 2 HIGH MASS Design -Verily Thermal Mass: 1,110.0 ft2 Exposed Slab Floor, 3.500" thick at Office Workout Bedroom 2 The HVAC System HVAC 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 108.0 ft2 Covered Slab Floor, 3.500" thick at Great Room Kitchen Nook HIGH MASS Design - Verify Thermal Mass: 1,815.0 ft2 Exposed Slab Floor, 3.500" thick at Great Room Kitchen Nook The HVAC System HVAC 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 858.0 W Covered Slab Floor, 3.500" thick at Office Laundry Hallway HIGH MASS Design - Verify Thermal Mass: 387.0 ft2 Exposed Slab Floor, 3.500" thick at Office Laundry Hallway The Roof R-38 Roof(R.38.2x12.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24APA760/58PH*110 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA760/58PH*110 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA760/58PH*110 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ACA736/58PH*090 includes credit for a 13.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-04712:33:58 ID: Page 5 of 32 PERFORMANCE CERTIFICATE:.. Residential • (Part 3 of 5) CF -1 R. Project Name Building T,,e m Single Family ❑ Addition Alone Date Horn Residence ❑ Multi Family ❑ Existing+ Addition/Alteration g/4/2012 ANNUAL ENERGY USE SUMMARY, ' Standard Proposed Margin TDV kBtu/ft2-yr , Space Heating 3.94 5.67 -1.72 Space Cooling . 52.10 46.86 5.24,• Fans 10.34 14.84 -4.49 Domestic Hot Water 5.57 3.75 1.82 ' Pum s 0.00 0.100. 0.00 r Totals 71.96 '71.11 0.84 Percent Better Than Standard: 1.2% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0deg Ext. Walls/Roof Wall Area Area ' Number of Dwelling.Units: 1.00 . - (N) '. 1,675 634 . Fuel Available at Site- Natural Gas (E) - 1,524: 428 Raised Floor Area: , 0 (s). 1,830 1,205 Slab on Grade Area: 6,550 (tM 1,246 429,- 25,Average AverageCeiling Height: 11.5 • Roof M 6,547 0 . i Fenestration Average U -Factor: 0.39 TOTAL: 2.692 Average SHGC: 0.28 Fenestration/CFA Ratio: 41.1% REMARKS t' STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the'Administrative Regulations and Part 6 the , Efficiency Standards of the California Code of Regulations. The documentation author hereby. certifies that the documentation is accurate and complete.. Documentation. Author ~ Company Scott Design and Title 24, Inc, ' 9/4/2012 Address 77-085 Michigan Drive Name Jon Scott ' City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed a Date . , The individual with overall design responsibility hereby certifies that the proposed building design represented.in this set of. construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with.any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and.field verification by an approved HERS rater.' Designer or Owner (per Business &Professions Code) Company Fedderly and Associates . . 'Address 38-747 Nopales Road Name Fedderly and Associates t City/State/Zip Palm Desert, Ca 92253 Phone (760) 773-0875 Signed License If . Date Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-04T12:33:58 ID: Pae 6 of 32 +t 1. _ - � • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Horn Residence Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration I Date 9/4/2012 OPAQUE SURFACE DETAILS Surface Type Area U Insulation Factor Cavit Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Roof 1,456 0.026 R-38 0 0 New 4.2.1-A9 Master Bedroom Wall 60 0.069 R-21 0 90 New 4.3.1-A6 Master Bedroom Wall 269 0.069 R-21 45 90 New 4.3.1-A6 Master Bedroom Wall 180 0.069 R-21 135 90 New 4.3.1-A6 Master Bedroom Wall 2921 0.069 R-21 225 90 New 4.3.1-A6 Master Bedroom Wall 367 0.069 R-21 315 90 New 4.3.1-A6 Master Bedroom Slab 1,246 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Slab 210 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Roof 1,926 0.026 R-38 0 0 New 4.2.1-A9 Office Workout Bedroom Wall 210 0.069 R-21 0 90 New 4.3.1-A6 Office Workout Bedroom Wall 258 0.069 R-21 90 90 New 4.3.1-A6 Office Workout Bedroom Wall 1711 0.069 R-21 135 90 New 4.3.1-A6 Office Workout Bedroom Wall 40 0.069 R-21 180 90 New 4.3.1-A6 Office Workout Bedroom Wall 73 0.069 R-21 225 90 New 4.3.1-A6 Office Workout Bedroom Wall 352 0.069 R-21 270 90 New 4.3.1-A6 Office Workout Bedroom Slab 816 0.730 None 0 180 New 4.4.7-A1 Office Workout Bedroom FENESTRATION SURFACE DETAILS ID Type Area LI-Factor' SHGC2 Azm Status Glazing Type Location/Comments 1 Window 20.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Master Bedroom 2 Window 11.3 0.390 NFRC 0.28 NFRC 45 New Dual non Metal Tinted Master Bedroom 3 Window 48.0 0.390 NFRC 0.28 NFRC 45 New Dual non Metal Tinted Master Bedroom 4 Window 11.3 0.390 NFRC 0.28 NFRC 45 New Dual non Metal Tinted Master Bedroom 5 Window 15.0 0.390 NFRC 0.28 NFRC 135 New Dual non Metal Tinted Master Bedroom 6 Window 75.0 0.390 NFRC 0.28 NFRC 135 New Dual non Metal Tinted Master Bedroom 7 Window 9.0 0.390 NFRC 0.28 NFRC 135 New Dual non Metal Tinted Master Bedroom 8 Window 125.0 0.390 NFRC 0.28 NFRC 225 New Dual non Metal Tinted Master Bedroom 9 Window 32.0 0.390 NFRC 0.28 NFRC 225 New Dual non Metal Tinted Master Bedroom 10 Window 32.0 0.390 NFRC 0.28 NFRC 225 New Dual non Metal Tinted Master Bedroom 11 Window 11.3 0.390 NFRC 0.28 NFRC 225 New Dual non Metal Tinted Master Bedroom 12 Window 48.0 0.390 NFRC 0.28 NFRC 225 New Dual non Metal Tinted Master Bedroom 13 Window 14.0 0.390 NFRC 0.28 NFRC 315 New Dual non Metal Tinted Master Bedroom 14 Window 15.0 0.390 NFRC 0.28 NFRC 315 New Dual non Metal Tinted Master Bedroom 15 Window 36.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Office Workout Bedroom 2 16 Window 40.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Office Workout Bedroom 2 (1) LI-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 4.5 2.5 4.0 0.1 4.0 4.0 3 Bug Screen 0.76 8.0 6.0 6.0 0.1 6.0 6.0 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 10.0 12.5 10.0 0.1 10.0 10.0 9 Bu Screen 0.76 8.0 4.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 8.0 4.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 4.5 2.5 4.0 0.1 4.0 4.0 12 Bug Screen 0.76 13 Bug Screen 0.76 3.5 4.0 6.0 0.1 6.0 6.0 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-04T12:33:58 ID: Pae 7 of 32 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Horn Residence Building Type m Single Family ❑Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/4/2012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor cavityTExterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Slab 1,110 0.730 None 0 180 New 4.4.7-A1 Office Workout Bedroom Roof 1,923 0.026 R-38 0 0 New 4.2.1-A9 Great Room Kitchen Nook Wall 128 0.069 R-21 0 90 New 4.3.1-A6 Great Room Kitchen Nook Wall 119 0.069 R-21 90 90 New 4.3.1-A6 Great Room Kitchen Nook Wall 171 0.069,R-21 180 90 New 4.3.1-A6 Great Room Kitchen Nook Wall 96 0.069 R-21 270 90 New 4.3.1-A6 Great Room Kitchen Nook Slab 108 0.730 None 0 180 New 4.4.7-A 1 Great Room Kitchen Nook Slab 1,815 0.730 None 0 180 New 4.4.7-A1 Great Room Kitchen Nook Roof 1,242 0.026 R-38 0 0 New 4.2.1-A9 Office Laundry Hallway Wall 350 0.069 R-21 0 90 New 4.3.1-A6 Office Laundry Hallway Door 24 0.500 None 0 90 New 4.5.1-A4 Office Laundry Hallway Wall 344 0.069 R-21 90 90 New 4.3.1-A6 Office Laundry Hallway Door 24 0.500 None 90 90 New 4.5.1-A4 Office Laundry Hallway Wall 50 0.069 R-21 180 90 New 4.3.1-A6 Office LaundryHallway Slab 858 0.730 None 0 180 New 4.4.7-A1 Office LaundryHallway Slab 387 0.730 None 0 180 New 4.4.7-A 1 Office Laundry Hallway FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 120.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Office Workout Bedroom 2 18 Window 120.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Office Workout Bedroom 2 19 Window 80.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Office Workout Bedroom 2 20 Window 80.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Office Workout Bedroom'2 21 Window 30.0 0.390 NFRC 0.28 NFRC 135 New Dual non Metal Tinted Office Workout Bedroom 2 22 Window 300.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Office Workout Bedroom 2 23 Window 110.0 0.390 NFRC 0.28 NFRC 225 New Dual non Metal Tinted Office Workout Bedroom 2 24 Window 4.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Office Workout Bedroom 2 25 Window 80.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Office Workout Bedroom 2 26 Window 15.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Office Workout Bedroom 2 27 Window 9.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Office Workout Bedroom 2 28 Window 63.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Great Room Kitchen Nook 29 Window 43.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Great Room Kitchen Nook 30 Window 95.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Great Room Kitchen Nook 31 Window 19.5 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Great Room Kitchen Nook 32 Window 18.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Great Room Kitchen Nook (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len I H t LExt RExt Dist Len Right Fin H t Dist Len H t 17 Bug Screen 0.76 10.0 12.0 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 10.0 12.0 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 8.0 10.0 2.0 0.1 2.0 2.0 20 IBug Screen 0.76 8.0 10.0 2.0 0.1 2.0 2.0 21 Bug Screen 0.76 22 Bug Screen 0.76 10.0 30.0 16.0 0.1 16.0 16.0 23 Bug Screen 0.76 10.0 11.0 6.0 0.1 6.0 6.0 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 9.0 7.0 6.0 0.1 6.0 6.0 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 8.0 3.0 6.0 0.1 6.0 6.0 32 JBug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-04712:33:58 ID: Pae 8 of 32 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Horn Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/4/2012 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 33 Window 58.5 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Great Room Kitchen Nook 34 Window 108.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Great Room Kitchen Nook 35 Window 300.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Great Room Kitchen Nook 36 Window 150.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Great Room Kitchen Nook 37 Window 43.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Great Room Kitchen Nook 38 Window 95.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Great Room Kitchen Nook 39 Window 26.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Office Laundry Hallway 40 Window 46.4 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Office Laundry Hallway 41 Window 18.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Office Laundry Hallway 42 Window 11.3 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Office Laundry Hallway 43 Window 26.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Office Laundry Hallway 44 Window 80.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Office Laundry Hallway (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 10.0 30.0 16.0 0.1 16.0 16.0 36 Bug Screen 0.76 10.0 15.0 20.0 0.1 20.0 10.0 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 10.0 8.0 4.0 0.1 4.0 4.0 --4 Ener Pro 5.1 by Ener Soft User Number: 6712 Run Code: 2012-09-04T12:33:58 ID: Pae 9 of32 CERTIFICATE OF COMPLIANCE: Residential : (Part 5 of 5) CF -1 R Project Name Horn Residence Building Type © Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/4/2012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built HVAC 1 Master Bedroom 1,456 14,560 HVAC 2 Office Workout Bedroom 2 1,926 23,112 HVAC 3 Great Room Kitchen Nook 1,923 24,999 HVAC 4 Office Laundry Hallway 1,242 12;420 Totals 6,5471 01 01 01 1 HVAC SYSTEMS System Name Qt . Heating Type Min. Eff. Cooling Type. Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC 2 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC 3 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC 4 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback I New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 E) New HVAC 4 Ducted Ducted JAttic, Ceiling Ins, vented 8.01 21 New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford White #M -1-100T 1 Large Gas All Pipes Ins 85,000 100 0.80 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft � 0 0 Q c System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑• Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-04712:33:58 ID: Pae 10 of 32 MANDATORY MEASURES SUMMARY: Residential Page 1 of 3 MF -1 R Project Name Horn Residence Date 1 9/4/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: §116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified Ll -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent Ll -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent Ll -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §1 50(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-04712:33:58 ID: Page 11 of32 .. � + � r - •..''L � r+'.fit J .� • • *� ♦ � r • ~ it '� • � . f i 1 � - , • ' 4 MANDATORY MEASURES SUMMARY:. Residential' Page 2.of'3 MF -1 R' Project Name r < Date Horn Residence 9/W2012 §150(m)1: All air -distribution system ducts and plenums installed; are sealed and insulated to meet the requirements of. CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-.• 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the - applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol'sealant that meets the requirements of UL 723. If mastic or tape is' used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used . §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area `of the ducts. - ' r §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dam ers' §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. } §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. , Cellular foam insulation shall be protected as above or painted with a coating•that is water retardant and provides shielding from solar radiation that can cause de radation of the material. §150(m)10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air-, Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: s .. §1 14(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions_ ; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with'at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. §114(b)2: Outdoor pools or,s as that have a heat pump or gas heater shall have a cover. " §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. §150(p): Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150(p). . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be'electronic and shall have an output frequency no less than 20 kHz. i. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by'§130(d), and shall not contain a medium screw -base socket. ' f §150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet thea licable re uirements of §150 k 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy., EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may: be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor,•dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a_ manual -on occu ant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of powerper linear foot of illuminated cabinet. 4�:+ EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-04T12:33:58 ID: Page 12 of 32 MANDATORY MEASURES SUMMARY: Residential Page 3 of 3 MF -1 R Project Name Date Horn Residence 9/4/2012 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry.rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11 : Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-04712:33:58 ID: Page 13 of 32 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Horn Residence 9/4/2012 System Name Floor Area HVAC 1 1,456 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM " Total Room Loads 797 Return Vented Lighting, Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible . Latent. CFM Sensible Output per System 110,000 17,854 1,109 408 21,978 Total Output (Btuh) 110,000 0 Output (Btuh/sqft) 75.5 1,031 1,080 Cooling System 0 , 0 Output per System " 59,000 0 0 0 0 Total Output (Btuh) 59,000 0 1,109 0 Total Output (Tons) 4.9 1,031 1,080 Total Output (Btuh/sqft) 40.5 Total Output (s ft/Ton) 296.1 1 19,916 24,138 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION ' Airflow (cfm) 2,000 Carrier 24APA760/58PH*110 ; 46,846 4,239 110,000 Airflow (cfm/sqft) 1.37 110,000 Jan 1 AM Airflow (cfm/Ton) 406.8 Outside Air (%) 0.0 % Total Adjusted System Output 46,846 (Adjusted for Peak Design conditions) TIME OF SYSTEM IPEAK 4,239 Aug 3 PM Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 69 OF 69 OF 121 OF Outside Air 0 cfm Supply Fan Heating Coil 121 OF 2,000 cfm ti ROOM 69 OF 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 78 / 63 '°F 78 / 63 OF 56 / 55 OF Outside Air Ar 0 cfm Supply Fan Cooling Coil 57 / 55 OF 2,000 cfm 44.3 % ROOM P' 78/63°F 78/63°F EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-04T12:33:58 ID: Page 14 of 32 t r HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Horn Residence Date 9/4/2012 System Name HVAC 2 Floor Area 1,926 ENGINEERING CHECKS SYSTEM LOAD Number of Systems, 1 COIL CFM Total Room Loads 1,459 Return Vented Lighting Return Air Ducts' Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM, Sensible Output per System 110,000 31;502 1,403 634 33,830 Total Output (Btuh) 110,000 0 Output (Btuh/s ft) 57.1 1,819 1,663 Cooling System 0 0 Output per System 59, 1 0001 0 0 < 0 0 Total Output (Btuh) 59,000 0 1,403 0 Total Output (Tons) 4.9 1,819 1,663 Total Output (Btuh/sqft) 30.6 Total Output (s ft/Ton) 391.7 35,140 37,155 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow (cfm) 2,000 Carrier 24APA760/58PH'110 46,819 4,566 110,000 Airflow (cfm/sqft) .1.04 Airflow (cfm/Ton) 406.8 " 'Outside Air (%) 0.0 % Total Adjusted System Output 46,819 (Adjusted for Peak Design conditions) - TIME OF SYSTEM PEAK 4,566 Aug 3 PM 110,000 Jan 1 AM Outside Air (cfm/sgf4) 0.00 Note: values above given at ARI conditions HEATING, SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) ' 26 OF 69 OF 0' Outside Air 0 cfm Supply Fan 2,000 cfm 69 of 69 OF 121 OF Heating Coil - 120 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 79 / 64 OF • 79 / 64 OF 57156 OF Outside Air 0 cfm Supply Fan Cooling Coil " 58 / 56 OF 2,000 cfm ROOM 45.0% 79 / 64 OF P . 78 /.63 OF r- EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-04T12:33:58 ID: Page 15 of 32 t I HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY ' Project Name Horn Residence Date 9/4/2012 ' System Name HVAC 3 " Floor Area 1,923 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,292 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible* Output per System 110,000 28,125 1,401 544 29,148 Total Output (Btuh) 110,000 0 Output (Btuh/s ft) 57.2 1,624 1,433 Cooling System 0 0 Output per System 59,000 0 0 0 0 Total Output (Btuh) 59,000 0 1,401 0 Total Output (Tons) 4.9 1,624 1,433 Total Output (Btuh/sgft) 30.7 Total Output s ft/Ton) 391.1 31,372 32,013 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24APA760/58PH'110 46,772 4,560 110,000 Airflow (cfm/sgft) 1.04 Airflow (cfm/Ton) 406.8 Outside Air (°i°) 0.0 % Total Adjusted System Output 46,772 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 4,560 Aug 3 PM 1 110,000 Jan 1 AM Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 69 OF Outside Air 0 cfm Supply Fan .2,000 cfm 69 OF 69 OF 121 OF Heating Coil e 120 OF r ROOM 70 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 79 / 64 °F 79 / 64 OF 57 / 56 OF Outside Air Supply Fan 0 cfm PP y Cooling Coil • 58/56 OF 2,000 cfm ' 44.9% ROOM 79/64°F 78/63°F EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-04T12:33:58 ID: Page 16 of 32 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Horn Residence Date 9/4/2012 System Name HVAC 4 Floor Area 1,242 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 623 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 14,752 975 199 14,541 Total Output (Btuh) 89,000 0 Output (Btuh/s ft) 71.7 852 715 Cooling System 0 0 Output per System 36,600 0 0 0 0 Total Output (Btuh) 36,600 0 1 852 1 16,456 975 0 Total Output (Tons) 3.1 715 Total Output (Btuh/sqft) 29.5 Total Output (s ft/Ton) 407.2 15,971 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow (cfm) 1,200 Carrier 24ACA736/58PH`090 30,097 1,285 89,000 Airflow (cfm/sgft) 0.97 Airflow (cfm/Ton) 393.4 Outside Air (%) 0.0 % Total Adjusted System Output 30,097 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1,285 Aug 3 PM 89,000 Jan 1 AM Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 69 OF Outside Air 0 cfm Supply Fan 1,200 cfm 69 OF 69 OF 139 OF Heating Coil 139 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak 112/78°F 79/63°F 79/63°F 55/54°F - 0' Outside Air Ar Supply Fan 0 cfm pp y Cooling Coil 56 / 54 OF 1,200 cfm , 42.1 % ROOM 79 / 63 OF 78 163 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-04712:33:58 ID: Page 17 of 32 ROOM LOAD SUMMARY 797 Project Name Horn Residence 408 Date 9/4/2012 System Name HVAC 1 ; Floor Area 1,456 ROOM LOAD SUMMARY. ` ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name • Mult. 7&M Sensible Latent. CFM Sensible Latent CFM Sensible Master Bedroom Master Bedroom 1 797 17,854 ,1,109 797 17, 854 1,109 .408 21,978 F • r • r , ' Total includes ventilation load for zonal systems. PAGE TOTAL TOTAL' 17,854 •17,854. 1,109 -1,1091 408 .21,978 '21,978 Ener Pro 5.1 b Ener Soft User Number: 6712 RunCode: 2012-09-04712:33:58 ID: Pae 18 of 32 797 797 . 408 ROOM LOAD SUMMARY r f PAGE TOTAL 1,459 Project Name Horn Residence r Date 9/4/2012 .System Name HVAC 2 t Floor Area, 1,926 ROOM LOAD SUMMARY TOTAL* . . ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible- Latent CFM . Sensible Office Workout Bedroom 2 Office Workout Bedroom 1 1,459 31,502 1,403 1,459 31,502 1,403 634 33,830 • Ener Pro 5.1 b Ener Soft User Number: 6712 RunCode: 2012-09-04712:33:58 ID:.' Pae 19 o�32 t r f PAGE TOTAL 1,459 31,502 1.,403 31, 634 33,830 '33,830 TOTAL* . 1,459 502 1,403 634" ' Total includes ventilation load for zonal systems. Ener Pro 5.1 b Ener Soft User Number: 6712 RunCode: 2012-09-04712:33:58 ID:.' Pae 19 o�32 , .. .Ar - , r . _ t r f PAGE TOTAL 1,459 31,502 1.,403 31, 634 33,830 '33,830 TOTAL* . 1,459 502 1,403 634" ' Total includes ventilation load for zonal systems. Ener Pro 5.1 b Ener Soft User Number: 6712 RunCode: 2012-09-04712:33:58 ID:.' Pae 19 o�32 t 31, '33,830 1,292 28,125 1,401 544 '29,148 1,292. 28,125 1,401 544 29,148 ROOM LOAD SUMMARY 14,752 975 Project Name Horn Residence . 14,541 Date 9/4/2012 System Name HVAC 4 199 Floor Area 1,242 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Office Laundry Hallway Office Laundry Hallway 1 623 14,752 975 623 14,752 975 199 14,541 u Y . r PAGE TOTAL TOTAL` ' Total includes ventilation load for zonal systems. Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-04T12:33:I 623 14,752 975 199 . 14,541 623 14,752 975 199 14,541 } ROOM HEATING PEAK LOADS ' Project Name w Horn Residence . Date 9/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Floor Area 1,456:0 ft2 Indoor Dry Bulb Temperature °- 70 OF Time'of Peak Jan 1 AM Outdoor Dry Bulb Temperature ` 26 OF ' Conduction • 1.064 Area U -Value - X 0.0260 X 0.0690 X 0.3900 .X 0.7300 X X X X X A X s X .X X X X .X X X X x X X X X '' ,X X x Ix X X to another room 10.00 X 0.312 Ceiling Height ACH X X X X X X X X X X X' X. X` X X X X X X x X X X- X X X x x X X �T OF, = = _ = - = = - - _ — = - = _ _ — = _ _ = _ _ 44 Btu/hr ' R-38 Roof(R.38.2x12.16) 1,456.0 44 1,666 R-21 Wall (W.21.2x6.16) r 1,168.1 44 3,546 Dual non Metal Tinted 466.9 44 8,012 Slab -On -Grade' perim = 162.0 44 5,203 _ • r i - . c - ' • Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface X 1,456 X Area ` Page Total 160 X AT 18,427 ' TOTAL HOURLY HEAT LOSS FOR ROOM 21,978 Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2012-09-04712:33:58 ID:. Page 22 of 32 ROOM HEATING PEAK LOADS - Project Name Date Horn Residence .9/4/2012 ROOM INFORMATION r DESIGN•CONDITIONS Y Time'of Peak Jan'1 AM, Floor Area 1,926.0 ft' Outdoor Dry Bulb Temperature 26 OF ROOM HEATING PEAK LOADS - Project Name Date Horn Residence .9/4/2012 ROOM INFORMATION r DESIGN•CONDITIONS Room Name Office Workout Bedroom 2 Time'of Peak Jan'1 AM, Floor Area 1,926.0 ft' Outdoor Dry Bulb Temperature 26 OF ,Indoor Dr' Bulb Temperature 70 °F Conduction a Area . X X x X X U -Value' ,X X X" x x 'AT '17 _r = - Btu/hr ROOM HEATING PEAK LOADS - Project Name Date Horn Residence .9/4/2012 ROOM INFORMATION r DESIGN•CONDITIONS Room Name Office Workout Bedroom 2 Time'of Peak Jan'1 AM, Floor Area 1,926.0 ft' Outdoor Dry Bulb Temperature 26 OF ,Indoor Dr' Bulb Temperature 70 °F Conduction Area . X X x X X U -Value' ,X X X" x x 'AT '17 _r = - Btu/hr R-38 Roof(R.382x12.16) - 1,926.0 0.0260 44 2,203 R-21 Wall (W.21.2x6.16) 1,104.0 0.0690 44 3,352 Dual non Metal Tinted ' $ 1,024'0 0.3900 44 :'_ 17,572 Slab -On -Grade ' Perim = 187.0 0.7300 w 44 6,006 s _ X x X x X �x •x x iX x X x X x x - _ = - - - } - .. t r - ` • + . 7 - N.x X X to•another l X x x• - = t - - ♦ • - r ti r w Items shown with an asterisk (`) denote conduction through ari interior surface room. - Page Total 29,133 _� 4,697 Infiltration:` 1.00 x " 1.064 ,X 1,926 x 12.00 X 0.260 41 60 J �X 44 Schedule . Air Sensible - . Area • ` Ceiling Height ACH 6T • ', Fraction TOTAL HOURLY HEAT LOSS FOR ROOM --.33,830 EnergyPro 5.1 by Energ Soft User Number: 6712 * R unCode: 2012-09-04712:33:58 ID: � Page 23 of 32 .. A e! moi•, r � �^' - ' ROOM HEATING PEAK LOADS` Project Name < < i _ �r Date r Horn Residence Y � � ` 9/4/2012 ROOM INFORMATION DESIGN CONDITIONS. Room Name Great Room Kitchen Nook Time of Peak ,Jan 1 AM Floor Area. -1,923.0 ftz Outdoor Dry Bulb Temperature - , 26, F RF ,Indoor Dr Bulb Temperature ! `r --70 IF Conduction ! AreaU-Value 'X X X X X X X X• X X AT Fwr_ _ y= = — Btu/hr. R-38 Roof(R.38. 2x I Z 16) J ' •' 1,923.0 l i 0.0260 s 44 2, 200 R-21 Wall. '(W.21.2x6.16) ` '_' �' ° 513.0 Y i ' 0.0690 44 1,557 Dual non Metal Tinted 993.0 0.3900 44 17,040 Slab On -Grade Perim = 114.0 0.7300 , T"44 3,662 X X. y .X X X X 'X to X X X X X X X X = — s„ r r vr •. .... ... .� 1• ' • - '� ' r• • ' • - } r " '.' f: Items shown withr an asterisk (') denote conduction through an inteiior surface another room Page Total `'_� •,24,459 ' , 4,689 Infiltration_:[ 1.00 X 1.064 X 1,923 X 60 f X ti : 44 " 4 ' Schedule Air Sensible' Area Ceiling Height ACH . �T � - r Fraction, •. t' t ;t �r c r" ro TOTAL HOURLYrHEAT LOSS FOR ROOM ., �. `rt' - ' ' 29,148 Energ Pro 5.1 b EnergySoft -' . User Number: 6712. RunCode: 2012-09-04T12:33:58 ID: a 'Page 24 of 32 ' l .v. i air 1 - . � T � t"4 • j. { �. _ ROOM HEATING PEAK LOADS Project Name Horn Residence - Date 9/4/2012 ROOM INFORMATION 5 DESIGN CONDITIONS ' Office Laundry Hallway Room Name . Y Y Floor Area1, 242.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan '1 AM Outdoor Dry Bulb Temperature • 26 °F Conduction 1.064 Area • X X rX X X X X X X X X X X X X' X -rX X X X X X X V y X X X X X to ,• Ceiling a U -Value X ;X X X X, X X X X X X X X X •X X X X JX X X OX V A X V X X X X -X AT 'F - _ = — = = — = = _ — _ = c — _ — - _ — — _ — — — — 44 Btufhr R-38 Roof(R.38.2X12.16) 1,242.0 0.0260 44 1,421 R-21 Wall (W.21.2x6.16) 744.3 '0.0690 44 2,260 Wood Door 48.0 0.5000 44 1,056 Dual non Metal Tinted 207.7 0.3900 44 .3,564 Slab -On -Grade - perim = 100.0 0.7300 44 3,212 .. '• M ' _ • - • ' .- ^ .. a r .. L. - * i y ' '1 - _ , Items shown with an asterisk (') denote conduction Infiltration: 1.00 X Schedule . Air Sensible w Fraction through an interior surface X 1,242 X Area another room J0.00 x 0.312 Height ACH Page Total 160 ] X AT 11,513 _ _ 3,029 TOTAL HOURLY HEAT LOSS FOR ROOM- 14.541 Energ Pro 5.1 b Energ Soft User Number: 6712 .. RunCode: 2012-09-04T12:33:58 ID: Page 25 of 32 RESIDENTIAL ROOM, COOLING LOAD•SUMMARY :. Project Name - s 7Date Horn Residence ' ' 9/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name r. Master Bedroom Outdoor Dry Bulb Temperature 112 OF 1,456.Oft' Outdoor. Wet Bulb Temperature 78 of .Floor Area.: ,. P . Indoor Dry Bulb Temperature 78 of Outdoor Daily Ranger - 34 OF Opaque Surfaces Orientation - Area U -Factor CLTD' Btu/hr ' R-38 Roof(R.38.2x12.16) (N) 1,456.0 X 0.0260 X 56.0 = .2,120 R-21 Wall (W.21.2x6.16) r R-21 Wall (W.21.2x6.16) R-21 Wall (W 21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) 60.0 .X . X X X . -X X X X • 0.0690 ' X X X X X X X X . 23.0 = t.= = = = - - - 95 269.4 ` 0.0690 29.0 539 180.0 0.0690 '' 31.0 385 291.7 0.0690. 31.0 624 367.0 0.0690 30:2 766 307 0.0 18.2 15.0 24.6 370 0.0 18.2 75.0 ` 24.6 1,848 0.0 ' Page Total 4,529 Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling toad Temperature Difference (CLTD) Shaded Unshaded Fenestration • Orientation Area GLF Area AGLF Btu/hr J-1 P-2 14-3 0-4 A-5' 5-6 S-7 4-8 H-9 (N) (NE) (NE) . (NE) (SE) (SE) (SE) (SM (StM 0.0 X X X ,X X X X X X 18.2 +. + + + + + + '+ + 20.0 X X X X X X X• X X 18.2 ,_{ = = = = = = = "= 364 0.0 18.2 11.3 27.2 307 0.0 18.2 48.0 27.2 1;305 0.0 s 18.2 11.3 27.2 307 0.0 18.2 15.0 24.6 370 0.0 18.2 75.0 ` 24.6 1,848 0.0 78.2 9.0 424.6 222 125.0 18.2 0.0 24.6 2, 2;74 11.71 18.2 20.3 24.6 713 Page Total 7,709 Internal Gain + Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment i` i 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration:' 1.064 X 0.87 X 79.67 X 34 = 2,496 Air Sensible ' CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,854 Latent Gain Btu/hr occupants 10 Occupants X 200 Btuh/occ. = 200 t Infiltration: 4,771 X 0.87 -x 79.67 X 0.00276 _ 909 Air Sensible CFM ELA AW TOTAL HOURLY,LATENT HEAT GAIN FOR ROOM 1,109 Ener Pro 5.1 by Ener Soft . User Number: 6712 RunCode: 2012-09-04T12:33:58 ID: Page 26 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY 4 Project Name z 7Date y a RESIDENTIAL ROOM COOLING LOAD SUMMARY 4 Project Name 7Date Horn Residence 9/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name '. Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,456.0 ft" Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF, Outdoor Daily Range:' 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X _ X X = X X - t { X X - .. X X _ X X _ X X, X X. _ X X _ Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) , Shaded Unshaded Fenestration Orientation Area GLF Area • GLF Btu/hr H-10 , -(SVV) 11.7 X 18.2 + 20.3 X 24.6 = 713 P-11 (SW)1 11.3 X 18.2 + 0.0 X - 24.6 = 206 Hcs-12 (SV0 0.0 X 18.2 + 48.0 X 24.6 = 1,182 R-13 (NVt9 -0.01 X 18.2 + 14.0 X 27.2 = 381 A-14. (NI/10 - 0.0 X 18.2 + 15.0 X 27.2 = 408 X + X. X + X ` - X + X _ X + X _ .. Page Total 2,890 Internal Gain '. Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. ' = 230 E ui ment 0.0 -Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.87 X X Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN•FOR ROOM 1i, 854 Latent Gain ,. Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. • � t �` _ - zoo Infiltration: 4,771 X 0.87 X 79.67 X 0.00276 :_ kF77 909 Air Sensible CFM - ELA AW t TOTAL HOURLY LATENT,HEAT GAIN FOR ROOM 1,109 Ener Pro 5.1 by Ener Soft User Number: 6712 Runcode: 2012-09-04T12:33:58 ID: Pa e 27 of 32 ' f 4 y RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Horn Residence 9/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Office Workout Bedroom 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,926.0 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' R-38 Roof(R.38.2x12.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W. 21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) 1,926.0 X X X X X X X X X 0.0260 X X X X X X X X X 56.0 = = _ = = = = = = 210.0 258.0 0.0690 23.0 0.0690 33.0 171.0 0.0690 31.0 40.0 0.0690 26.0 73.0 0.0690 31.0 352.0 0.0690 33.0 18.2 15.0 18.2 65.0 34.8 15.0 Btu/hr, 2, 804 333 - 587 366 I- 8021 Page Total L Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded I Fenestration B-15 1-16 12-17 12-18 10-19 10-20 G-21 2-22 13-23 Orientatinn (N) (N) (N) (N) (E) (E) (SE) (S) (SM Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = 0.0 18.2 36.0 18.2 0.0 18.2 40.0 18.2 0.0 18.2 120.0 18.2 0.0 18.2 120.0 18.2 15.0 18.2 65.0 34.8 15.0 18.2 65.0 34.8 0.0 18.2 30.0 300.0 18.2 0.0 98.6 18.2 11.4 Page Total 5,1201 Btu/hr . 655 728 2,183 2,183 2,536 2,536 739 5,457 2,0751 Internal Gain Btu/hr 230 Occupants 1.0 Occupants X 230 Btuh/occ. _ Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.87 X 105.39 X 34 177 3,302 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 31,502 Latent Gain Occupants 1.0 Occupants X 200 Btuh/occ. Infiltration: 4,771 X 0.87 X 105.39 X 0.00276 = Air Sensible CFM ELA AW I TOTAL HOURLY L HEAT GAIN FOR ROOM 1 Btu/hr 200 1,203 1,403 Page 28 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Horn Residence ' , 9/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Office Workout Bedroom 2 Outdoor Dry Bulb Temperature _ 112 OF Floor Area 1,926.0 ft 2 .Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature ' ' 78 °F, Outdoor Daily Range: 34 OF, Opaque Surfaces Orientation Area j 4 U -Factor CLTD' Btu/hr X X _ i X X = , X X - X X , - X X - • X X - X X - X X - X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 'r 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 1-24 (VV) 0.0 X 18.2 + 4.0 X 34.8 = 139 10-25 0.0 X .18.2 + 80.0 X 34.8 = 2,785 A-26 (VV) - 0.0 X 18.2 +' 15.0 X 34.8 = 522 5-27 NO 0.0 X 18.2 + 9.0 X 34.8 = 313 X + X - X + X = 4 X + X - X + X = - X + X = Page Total 3,760 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = -0 Infiltration: 1.064 X 0.87 X 105.39 X 34 _ -` 3,302 Air Sensible. CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM . 31,502 Latent Gain Btu/hr - Occupants 1.0 Occupants X - 200 Btuh/occ. = 200 Infiltration: 4.77.1 X. 0.87 X 105.39 X 0.00276 = 1,203 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,403 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-04T12:33:58 ID: Pae 29 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY Horn Residence 1 9/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room Kitchen Nook Outdoor Dry Bulb Temperature 112 OF Floor Area 1,923.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces R-38 Roof(R. 38.2x 12.16) R-21 Wall (W.21.2x6.16) _. R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation Area X X X X X X X X X U -Factor ' X X, X X X X X X X CLTD' = = = = = = = = 1,923.0 0.0260 56.0 128.0 0.0690 23.0 118.5 0.0690 33.0 170.5 0.0690 26.0 96.0 0.0690 33.0 11.5 18.2 + 8.0 34.8 0.0 18.2 + 18.0 34.8 0.0 I= + + 58.5 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) 1 Fenestration 1-28 C-29 Ccs -30 M-31 F-32 L-33 E-34 2-35 3-36 I Internal Gain Orientation (N) (N) (N) (E) (E) (S) (S) (S) Btu/hr 203 270 306 219 1 3,7971 Shaded Area X X X X X X X X X GLF Unshaded Area X X X X X X X18.3 X X GLF = = = = = = _ = = 0.0 18.2 + 63.0 18.2 0.0 18.2 + + 43.0 18.2 0.0 18.2 95.0 18.2 11.5 18.2 + 8.0 34.8 0.0 18.2 + 18.0 34.8 0.0 18.2 + + 58.5 18.3 0.0 18.2 108.0 300.0 18.2 + 0.0 18.3 150.0 18.2 + 0.0 34.8 Page Total 1.0 Occupants X 230 Btuh/occ. 0.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 0.87 X 105.23 X 34 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain Occupants 1.0 Occupants X 200 Btuh/occ. Infiltration: 4,771 X 0.87 X 105.23 X 0.00276 = Air Sensible CFM ELA AW Btu/hr 1,146 782 1,728 488 A627 2,729 15,996 Btu/hr 230 0 3,297 28,125 Btu/hr 200 1,201 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,401 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-04T12:33:58 ID: Page 30 of 32 'RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Horn Residence - 9/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room Kitchen Nook Outdoor Dry Bulb Temperature - 112 OF Floor Area ' ' 1,923.0 ft2 Outdoor Wet Bulb Temperature '78 OF Indoor Dr Bulb Temperature 78 OF Outdoor Daily Range: 34 OF s Opaque.Surfaces Orientation Area U -Factor • CLTD', Btu/hr - - X X X _ x x _ x x _ x x _ x X x X _ X • X - X x = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Coojing Load Temperature Difference (CLTD) r Shaded Unshaded Fenestration Orientation Area GLF Area GLF. - Btu/hr C-37 (lM 0.0 X 18.2 +. 43.0 X '34.8 = 1,497 Ccs -38 (VO 0.0 X 18.2 + 95.0 X 34.8 = 3,307 x + X - ' x + x _ X + X X + x — X _ + X _ o x + i x = �• X + X - • Page Total 4,804 Internal Gain Btu/hr - Occupants 1.0 Occupants X 230 Btuh/occ. `" 230 Equipment 0.0 Dwelling Unit, X 1,600 Btu ' = 0 Infiltration 1.064 x 0.87 `x' 105.23 x 34 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 28,125 Latent Gain Btu/hr 'Occu ants 1.0 Occupants X 200 Btuh/occ. ' _. • 200 Infiltration: 4,771 X 0.87 X 105.23 X 0.00276 = � • ; ' • 1.201 Air Sensible CFM- ELA AW + . TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,401 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-04712:33:58 ID: Page 31 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Horn Residence 9/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Office Laundry Hallway Outdoor Dry Bulb Temperature 112 OF Floor Area 1,242.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x12.16) (N) 1,242.0 X 0.0260 X 77.0 = 2,486 R-21 Wall (W.21.2x6.16) (N) 350.0 X 0.0690 X 31.0 = 749 Wood Door (N) 24.0 X 0.5000 X 32.0 = 384 R-21 Wall (W.21.2x6.16) (E) 344.3 X 0.0690 X 44.0 = 1,045 Wood Door (E) 24.0 X 0.5000 . X 47.0 = 564 R-21 Wall (W.21.2x6.16) (S) 50.0 X 0.0690 X 38.0 = 131 X X = X X = X X = Page Total 5,360 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr N-39 (N) 0.0 X 21.7 + 26.0 X 21.7 = 563 K-40 (E) 0.0 X 21.7 + 46.4 X 46.6 = 2,162 0-41 (E) 0.0 X 21.7 + 18.0 X 46.6 = 839 P-42 (E) 0.0 X 21.7 + 11.3 X 46.6 = 526 N-43 (E) 0.0 X 21.7 + 26.0 X 46.6 = 1,211 15-44 (S) 80.0 X 21.7 + 0.0 X 27.8 = 1,732 X + X = X + X = ` X +1 X = Page Total 7,033 Internal Gain Btu/hr Occupants 1.0 Occupants X E 230 Btuh/occ. _ 230 Equipment 0.0 Dwelling Unit X 1,200 Btu = 0 Infiltration: 1.064 X 0.87 X 67.96 X 34 = 2,129 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM I 14,752 Latent Gain Btu/hr Occupants 1.0 • Occupants X 200 Btuh/oCC. _ 200 Infiltration: 4,771 X 0.87 X 67.96 X 0.00276 = 775 Air Sensible -.CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 975 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-04T12:33:58 ID: Pa e 32 of 32 BUILDING ENERGY ANALYSIS REPORT • •. J 'h t PROJECT: Horn Guest House ` ^Y Lot 227 -The Hideaway ' La Quinta, Ca 92253.. Project Designer: Fedderly and Associates r 38-747 Nopales-Road Palm Desert, Ca 92253 • (760) 773-0875 - Report Prepared by: Jon Scott j -Scott Design and Title 24,, Inc, t ,. 77 -085 -Michigan Drive , A - a Palm Desert, Ca 92211 , Date: r 7/10/2012 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is. + authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.' This program developed by EnergySoft, LLC - www.energysoft.com. Y fnerg Pro 5.1 by Energ Sof User Number: 6712 RunCode- 2012-07-10709:29:05 ID: EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 6712 . r PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Horn Guest House Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 7/10/2012 Project Address Lot 227 -The Hideaway La Quinta California Energy Climate Zone, CA Climate Zone 15 Total Cond. Floor Area 1,102 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R. must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features (see Part 2 of 5) Status Roof Wood Framed Attic R-38 1,102 Radiant Barrier New, Wall Wood Framed R-21 1,423 New Slab Unheated Slab -on -Grade None 1,102 Perim = 152' New - FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status Front (N) 46.4 0.390' 0.28 none none Bug Screen New Left (E) 31.2 0.390 0.28 none none Bug Screen New Rear (S) 149.0 0.390 0.28 none none Bug Screen New Right (VV) 98.4 0.390 0.28 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff • Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION Location . Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution r Status 1 Large Gas 100 0.80 All Pipes Ins New Energ Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-07-10709:29:05 ID: Page 3 of 15 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Horn Guest House Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 7/10/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford White #M-1-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. The Roof R-38 Roof(R.38.2x12.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24APA760158PH'110 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-07-10709:29:05 ID: Page 4 of 15 PERFORMANCE CERTIFICATE: Residential (Part 3 of, 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone - Date - Horn Guest House • ❑ Multi Family ❑ Existing+ Addition/Alteration , 7/10/2012 f Standard Proposed Margin TDV (kBtu/ff2-yr) . Space Heating 4.89 3.37 1.52 y F Space Cooling 67.34 46.'17 21.17 Fans . 13.38 14.75 -1.37 Domestic Hot Water 23.84 13.32 10.52 Pumps _ t 0.00 0.00 0.00 . . r Totals 109.46 77.61 31.85 Percent Better Than Standard: 29.1 i BUILDING. COMPLIES' - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation:' t (N) 0deg 'Ext. Walls/Roof Wall Area • Area -. Number of Dwelling Units: 1.00 (N) 403 46 Fuel Available at Site.: Natural Gas (E) 471 .- •: , ' 31' , `, Raised Floor Area: 0 (S) • 403 149. Slab on Grade Area: 1,102 (vv)• 471 98 Average Ceiling Height: 11.5 Roof .. 1,102 0' Fenestration. Average U -Factor: 0.39 - TOTAL: 325 Average SHGC: 0.28- Fenestration/CFA Ratio: • 29.5% ,REMARKS41 STATEMENT OF COMPLIANCE: J PERFORMANCE CERTIFICATE: Residential (Part 3 of, 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone - Date - Horn Guest House • ❑ Multi Family ❑ Existing+ Addition/Alteration , 7/10/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV (kBtu/ff2-yr) . Space Heating 4.89 3.37 1.52 y F Space Cooling 67.34 46.'17 21.17 Fans . 13.38 14.75 -1.37 Domestic Hot Water 23.84 13.32 10.52 Pumps _ t 0.00 0.00 0.00 . . r Totals 109.46 77.61 31.85 Percent Better Than Standard: 29.1 i BUILDING. COMPLIES' - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation:' t (N) 0deg 'Ext. Walls/Roof Wall Area • Area -. Number of Dwelling Units: 1.00 (N) 403 46 Fuel Available at Site.: Natural Gas (E) 471 .- •: , ' 31' , `, Raised Floor Area: 0 (S) • 403 149. Slab on Grade Area: 1,102 (vv)• 471 98 Average Ceiling Height: 11.5 Roof .. 1,102 0' Fenestration. Average U -Factor: 0.39 - TOTAL: 325 Average SHGC: 0.28- Fenestration/CFA Ratio: • 29.5% ,REMARKS41 STATEMENT OF COMPLIANCE: J This certificate of compliance lists the building features and specifications needed' r to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency -Standards of.the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. , .Documentation Author " Company Scott Design and Title 24, Inc, 7/10/2012' - 77-085 Michigan Drive Name Jon Scott Address ' City/State/zipCityIState/zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date ' The individual with overall design -responsibility hereby certifies that the proposed building design represented in this set of construction documents is'consistent with the other compliance forms and worksheets, with the specifications, and . with any other calculations submitted with this permit application, and ,recognizes that compliance using duct design, duct sealing, verification of refrigerant charge; insulation installation quality; and building envelope sealing require_ .' installer testing and certification and field verification by an approved HERS rater. Designer.or Owner'(per Business & Professions Code) , t' Company Fedderly and Associates Address 38-747 Nopales Road Name Fedderly and Assoc'iate"s, °Phone City/State/Zip Palm Desert, Ca 92253. (760) 773-0875 - Signed License #> Date L Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-07-10709:29:05 ID: Pae 5 of 15 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Horn Guest House Building Type m Single Family ❑Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1711012012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,102 0.026 R-38 0 0 New 4.2.1-A9 Guest Bedroom Wall 357 0.069 R-21 0 90 New 4.3.1-A6 Guest Bedroom Wall 440 0.069 R-21 90 90 New 4.3.1-A6 Guest Bedroom Wall 254 0.069 R-21 180 90 New 4.3.1-A6 Guest Bedroom Wall 373 0.069 R-21 270 90 New 4.3.1-A6 Guest Bedroom Slab 1,006 0.730 None 0 180 New 4.4.7-A1 Guest Bedroom Slab 96 0.730 None 0 180 New 4.4.7-A1 Guest Bedroom FENESTRATION SURFACE DETAILS ID Type Area Ll -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 24.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom 2 Window 4.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom 3 Window 4.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom 4 Window 4.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom 5 Window 10.4 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom 6 Window 10.4 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Guest Bedroom 7 Window 10.4 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Guest Bedroom 8 Window 10.4 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Guest Bedroom 9 Window 64.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Guest Bedroom 10 Window 85.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Guest Bedroom 11 Window 24.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Guest Bedroom 12 Window 10.4 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Guest Bedroom 13 Window 64.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Guest Bedroom (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-07-10709:29:05 ID: Page 6 of 15 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Horn Guest House Building Type D Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 7/10/2012 BUILDING ZONE INFORMATION System Name Floor Area ft Zone Name New Existing Altered Removed Volume Year Built HVAC 1 Guest Bedroom 1,102 12,673 10201 Totals 1 1,1021 0 HVAC SYSTEMS System Name Ot . Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback ' New HVAC DISTRIBUTION System Name Duct Heating Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS S stem Name Ot . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford White #M -1-100T 1 Large Gas All Pipes Ins 85,000 100 . 0.80 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length . ft = _ o 76 -moo NPipe a c System Name . Length Pipe Diameter Insul. Thick. QtHP Plenum Outside Buried Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-07-10T09:29:05 ID: Page 7 of 15 MANDATORY MEASURES SUMMARY: Residential Page 1 of 3 MF -1 R Project Name Horn Guest House Date 711012012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: §116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified Ll -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). §117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent Ll -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed desi n labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent Ll -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent Ll -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM Ell 677-95(2000) when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 erm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to -Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EriergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-07-10709:29:05 ID: Page 8 of 15 MANDATORY MEASURES SUMMARY: Residential Page 2 of 3 MF -1 R Project Name Date Horn Guest House 1 7/10/2012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. §114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ro rammed to run only during off-peak electric demand periods. §150(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150( ). Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. §150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2012-07-10709:29:05 ID: Page 9 of 15 MANDATORY MEASURES SUMMARY: Residential Page 3 of 3 MF -1 R Project Name Date Horn Guest House '7/10/2012 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other'than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that.the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low -efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-07-10709:29:05 ID: Page 10 of 15 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Horn Guest House 7/10/2012 System Name Floor Area HVAC 1 1;102 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 648 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent ' CFM Sensible Output per System 110,000 14,671 888 346 18,728 Total Output (Btuh) ' 110,000 Return Vented Lighting Return Air Ducts 0 Output (Btuh/s ftj 99.8 847 920 Cooling System Return Fan 0 0 Output per System 59,000 Ventilation 0 0 0 0 0 Total Output (Btuh) 59,000 Supply Fan 0 0 Total Output (Tons) 4.9 Supply Air Ducts 847 920 Total Output (Btuh/sqft) 53.5 Total Output (s ft/Ton) 224.1 TOTAL SYSTEM LOAD 1 16,365 888 20,568 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow (cfm) 2,000 Carrier 24APA760/58PH'110 46,968 4,001 110,000 Airflow (cfm/sqft) 1.81 Airflow (cfm/Ton) 406.8 Outside Air (°i°) 6.0% Total Adjusted System Output 46,968 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 4,001 Aug 3 PM 110,000 Jan 1 AM Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 70 OF O 70 OF 121 OF � Outside Air 0 cfm Supply Fan Heating Coil r 121 OF 2,000 cfm ROOM 70 OF 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 78/63°F 78/63°F • 56/55°F Outside Air Ar 0 cfm Supply Fan ,Cooling Coil 2,000 cfm 57 / 55 OF 43.9% ROOM 78/63°F .4 A I 78/63°F EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-07-10T09:29:05 ID: - Page 11 of 15 648 14, 671 , , 888 j461' 18, 728 648 14, 671 888 • - * .. 346 . ,18, 728 ROOM HEATING PEAK LOADS Project Name Date Horn Guest House 7/10/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name i Guest Bedroom Time of Peak • Jan IAM. Floor Area F 1,102.0 ft' Outdoor Dry Bulb Temperature ' 26 OF Indoor Dr .Bulb Temperature 70 OF ` Conduction Area U -Value AT °F, 'Btu/hr R-38 Roof(R. 38.2x 12.16) R-21 Wall,(W.21:2x6.16) ' Dual non Metal Tinted Slab -On -Grade j T. A + X X X X X X XX x X X X X X X X X X X X x X x X X X X X X X X X X X X X X X X X X X X X V X 44 = = = = = - - - - - _ - - = - = 1,261 0.0690 :44 4,320 0.3900 44 5,577 0.7300 44 T` 4,882 } . . r T - X X X X x X X X X X X XV X X - = - = - = y' } o } . . r Items shown with an asterisk (*) denote conduction through an interior surface to another room Page Total 16,040 Infiltration:[ 1.00 X 1.064 X 1,102 X 11.50 `X 0.272 / 60 X ` 44 = 2,687 Schedule Air Sensible ., Area Ceiling Height ACH t• AT Fraction J . 1 TOTAL HOURLY HEAT LOSS FOR ROOM +18,728 Energ Pro 5.1 by Energ Soft • User Number. 6712 RunCode: 2012-07-10T09:29:05 ID: Page 13 of 15 } RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Horn Guest House 1 7/10/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1;102.0 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Dailv Range: 34 OF Opaque Surfaces R-38 Roof(R.38.2x12.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Area, X X X X X X X X X U -Factor X X •X X X X X X X CLTD' = = = = = = = = = 1,102.0 0.0260 56.0 356.6 0.0690 23.0 439.8 0.0690 33.0 254.0 0.0690 26.0 372.6 0.0690 33.0 18.2 4.0 18.2 0.0 18.2 10.4 18.2 0.01 18.2 10.4 34.8 0.0 18.2 10.4 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fenestration J-1 J-1 J-1 J-1 J-1 J-1 J-1 J-1 J-1 Orientation (N) (N) (N) (N) (N) (E) (E) (E) (S) Shaded Area X X X X X X X X X GLF + + + + + + + + + Unshaded Area X X X X X X X X X GLF = = = = = = = = = 0.0 18.2 24.0 18.2 0.0 18.2 4.0 18.2 0.0 18.2 4.0 18.2 0.0 18.2 4.0 18.2 0.0 18.2 10.4 18.2 0.01 18.2 10.4 34.8 0.0 18.2 10.4 34.8 0.0 18.2 10.4 34.8 0.0 18.2 64.0 18.3 Page Total Btu/hr 1,605 566 1,001 456 848 4,4 Btu/hr 437 73 73 73 189 362 362 362 1,168 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 I Infiltration: 1.064 X 0.87 X 60.30 X 34 = C Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,671 Latent Gain Btu/hr Occupants 1.0 Occupants X 200Btuh/occ. = 200 Infiltration: 4,771 X 0.87 X 60.30 X 0.00276 = 688 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 888 2 RESIDENTIAL ROOM COOLING LOAD SUMMARY. , Project Name Date Horn Guest House ,7/10/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Bedroom Outdoor'Dry Bulb Temperature 112 OF Floor Area .1,102.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor bai'ly Range: 34 OF Opaque Surfaces Orientation Area 6 -Factor' CLTD' Btu/hr X X• X X X X _ 4 y X �X = F X r' X - w X XX _ q X X - X X _ • X X w _ Page Total` 0 Items shown with an asterisk (") denote conduction through an interior surface to another room. ' 1. Cooling Loaa Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area - .GLF Area GLF Btu/hr' J-1 (S) 0.0 X t8.2 + X' 85.0 X 18.3 = 1,552 J-1 (VV) 0.0 X 18.2 + 24.0 X 34.8 = 836 J-1 (lM 0.0 X 18.2 +• 10.4 X. 34.8 = 362 J-1 (Vl�• 0.0 X18.2 + 64.0 'X 34.8 = 2,228 X + X _ X + I X = X + X _ X + X _ - X + X _ Page Total 4,977 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. Equipment 0.0 Dwelling.Unit X 1,600 Btu Infiltration: 1.064 X 0.87 X 60.30 X 34 = 1,889 Air Sensible CFM ELA - AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,671 Latent Gain Btu/hr Occupants 1.0 Occupants -X, 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.87 X 60.30 X 0.00276 = 688 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 888 Ener Pro 5.1 by Ener Soft • User Number: 6712 Runcode: 2012-07-10709:29:05 ID Pae 15 of 15 E_Pectronically.Filed�by Tim'Scott-and'Authenticated'at-Ca10ERTS:com--.9/7/2012,.._. Electronically_Signed;at CalCERTS.com by Robin Lever (Fedderly &.Associates) 9/7/2012) PERFORMANCE CERTIFICATE: Residential, Part 1 of5 aCF-1 R Project Name" Hom Guest House Building Type m Single Family ❑Addition Alone ❑ Multi Family. ❑ Existing+ Addition/Alteration Date 9/7/2012 Project Address Lot 227 -The Hideaway' La Quinta . California Energy Climate Zone CA Climate Zone 15� Total Cond. Floor Area • 1,102 Addition# n/a of Stories 1. FIELD INSPECTION ENERGY CHECKLIST ) , IZI Yes ❑ No HERS Measures -If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No` Special Features '- If Yes, see Part 2 of 5 of this form for details. ` INSULATION Area Special Construction type Cavity (ft)' Features see Part 2 of 5).' Status Roof Wood Framed Attic R-38 1,102 ' Radiant Barrier New Wald Wood Framed R-21 1,423 New Slab Unheated Slab -on -Grade None 1,102 Perim = 152' New 'Exterior FENESTRATION U- Orientation: Areae Factor SHGC Overhan Sidefins Shades 4 Status, Front (N) 46.4 0.390 0.28 none none Bug Screen New Left (E) -.;,r.�;:�:,31.2 r 0.390,E>0.28,�.nonem. ..,a� none .�.., g ,,x�u�.;,_ New -Screen Bu , Rear (S).?" , - 149.0' , 0:390 • ' 0.28 none* none c - ,;Bug Screen.. New, Right(lM ;' r x;98.4 '0.390 028 =none none''A "BugScreen New • r:,`•. � �� t.�.'F,- '�T�•X„y � °.^�..,-'`'`,�-+'-'� `---"..���:. r � °v o'��t ct�_._'_�•. _ x f-�i #.. "��'``i°k - a Y.. �✓ r' es, �,; Q� I I -A 000nVPr) FOR CONS-TRUG TION HVAC SYSTEMS ' t0 S �2 Y Ot . HeatingWin. Eff Coolie ' DA tat Status 1 Central Furnace 80% AFUE ' Split Air Conditioner .16.5 SEER Setback New HVAC DISTRIBUTION Duct ; Location a Heating Cooling Duct'Location - ' .,R -Value• Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New ,WATER HEATING Qt ' T e Gallons Min. Eff -Distribution Status 1 Large Gas 100 0.80 All Pipes Ins New,-. •Energ Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-07-10T09:29:05 ID: Pae 1 of 5 "Reg: 212-NO04962BA-000000000-0000 ,Registration Date/Time:'2012/09/07 12:44:33 HERS Provider: CalCERTS, Inc �� ♦ h Electronically-Fi'led' byrTim.Scott and Authenticated at CalCERTS.cor - 9/7/2012 + Electronically Signed at CalCERTS.Com by Robin Lever (Fedderly & Associates) 9/7/2012 ' PERFORMANCE. CERTIFICATE: Residential (Part 2 of 5) CF71 R' Project Name Building Type- ® Single Family ❑ Addition Alone - Date , Horn Guest House ❑.Multi Family ❑ Existing+ Addition/Alteration 1 9/7/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written" ' justification and documentation, and special verification to be used with the performance approach. The enforcement agency' determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford White #M-1-100T6BN is a non-NAECA large storage gas water heater..Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. ' The Roof R-38 Roof(R.38.2x 12.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. jam[ �j�` �"�.�""'^• jam' I�•('�'` '7 .i',,ry� ,jj sR+ HERS REQUTAE' D VERIFICATION Items inthis'section require field testing'and/or verification by,,a certified°HERS-Rater.°-The inspector.must receive a completed CF -4R form for eacti of the measures listed below for final to be given. The Cooling System Carrier 24APA 760/56PH*110 includes credit fora 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.' The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct' leakage meets the specified criteria. Ener Pro 5.1 by Ener Soft " User Number: 6712 RunCode: 2012-07-10709:29:05 ID: Page 2 of 5 Reg: 212-N0049628A-000000000-0000 'Registration Date/Time: 2012/09/07 !12:44`:33- HERS Provider-- CalCERTS, Inc _ , Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/7/2012 Electronically Signed at CalCERTS.com by Robin Lever (Fedderly & Associates) 9/7/2012 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project NameBuilding Type m Single Family ❑ Addition Alone Date Hom Guest House ❑ Multi Family ❑ Existing+ Addition/Alteration 9/7/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV, kBtu/ft2- r Space Heating 4.89 3.37 1.52 Space Cooling 67.34 46.17 21.17 Fans 13.38 14.75 -1.37 Domestic Hot Water. 23.84 13.32 10.52 Pumps 0.00 0.00 0.00 Totals 109.46 77.61 31.85 Percent Better Than Standard: 29.1 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 403 46 Fuel Available at Site: Natural Gas (E) 471 31 Raised Floor Area: 0 (S) 403 149 Slab on Grade Area: 1,102 (W) 471 98 Average Ceiling Height: ,11.5 Roof 1,102 0 Fenestration Average U -Factor: 0.39 TOTAL: 325 Avera fe SHGC: 0.28 Fenestration/CFA Ratio: 29.5% REMARKS 'X f STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. , The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, Address 77-085 Michigan Drive Name Tim Scott 91712012 City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Fedderly and Associates Address 38-747 Nopales Road Name Fedderly and Associates City/State/Zip Palm Desert, Ca 92253 Phone (760) 773-0875 Signed License # Date Ener Pro 5.1 by Ene Soft User Number: 6712 RunCode: 2012-07-10709:29:05 ID: Page 3 of 5 Reg: 212-N0049628A-000000000-0000 Registration Date/Time: 2012/09/07 12:44:33 HERS Provider: CalCERTS, Inc Electronically Filed by�Tim,Scott and Authenticated at CalCERTS:Com - 9/7/2012 Electronically Signed at CalCERTS.com by Robin, Lever'(Fedderly & Associates) 9/7/2012 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5), CF -1 R Project Name Hom Guest House Building Type 10 Single Family ❑ Addition Alone, ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/7/2012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,102 0.026 R-38 0 0 New 4.2.1-A9 Guest Bedroom Wall 357 0.069 R-21 0 90 New 4.3.1-A6 Guest Bedroom, Wall 440 0.069 R-21 90 90 New 4.3.1-A6 Guest Bedroom Wall 254 0.069 R-21 180 90 New 4.3.1-A6Guest Bedroom Wall 373 0.069 R-21 '270 90 New 4.3.1-A6 Guest Bedroom Slab 1,006 0.730 None - 0 180 New 4.4.7-A1 Guest Bedroom , Slab 96 0.730 None 0 180 New 4.4.7-A1 Guest Bedroom FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 24.0 0.390 NFRC 0.28 1 NFRC 0 New Dual non Metal Tinted Guest Bedroom " 2 • Window 1 4.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom - 3 : Window 4.0 0.390 NFRC ' 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom 4 Window 4.0 0.390 NFRC - 0.28 NFRC 0 New Dual non Metal Tinted Guest Bedroom , 5 Window- 10.4 0.390 NFRC 0.28.. NFRC-.-.... _ . -0 New .,-_ . Dual non Metal Tinted y,,., Guest Bedroom 6 Window. `x,10.4 0.390 NFRC ; `'f 0.28' NFRC 190 New �. Dual'non Metal Tinted.1,- ` ! Guest Bedroom 7 Window '10.4 • 0.390 NFRC q, iA 0.28 'NFRC 90 New , 1- Dual non Metal Tinted, r Guest Bedroom 8 Window 10.4 ";'"0.390. NFRC q . 0.28 NFRC -,f 90 New �,-'Dual non,Metal Tinted 1 .. Guest Bedroom 9 - Window 64.0 ,j' 0:390 NFRC 0.28 NFRC,, 1J 180 New, c Dual non Metal Tinted Guest.Bedroom--, , 10 Window ,e: j85.10.. -'Q.,390, NFRC t 0.28 NFRC �r ,180 'New-,-. Dual non Metal Tinted. Guest Bedroom ` 11 Windows K (•24.0! ;_, 0.390 NFRC,-!;qO;28 NFRC New' ° . Dual non.Metal Tinted f .Guest Bedroom,f ' 12 Window • 10.4 0.390 NFRC " " " 0.28 NFRC - 270 New Dual non Metal Tinted "' Guest Bedroom _ 13 Window 64.0 0.390 NFRC 0.28 NFRC - 270 New Dual non Metal Tinted Guest Bedroom r (1). U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC T e: 116-B = Default Table from Standards, NFRC = Labeled Value ; EXTERIOR SHADING DETAILS ID Window Ove hang Left Fin Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len Right Fin • s H t Dist Len H t •' 1 Bug Screen 0.76 2 ._ Bug Screen 0.76 3. Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen ' 0.76 e 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0:76 ' • 12 Bug Screen ,_ 0.76 13 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number. 6712 Run Code: 2012-07-10709:29:05. ID: Page 4 of 5 " Reg:'212-N0049628A-000000000-000O,a Registration Date/Time:`2012/09/07.12:44:33 HERS Provider: CalCERTS':Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/7/2012 Electronically Signed at CalCERTS.com by Robin Lever (Fedderly & Associates) 9/7/2012 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Hom Guest House Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/7/2012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built HVAC 1 Guest Bedroom 1,102 12,673 Totals 1,102 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff: Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New i r HVAC DISTRIBUTION ' System Name Heatiri` Duct � � , Ducts' Coolin Duct Location R -Value Tested? Status HVAC 1 Ducted Ducted JAttic, Ceiling Ins, vented 8.0 IZI New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status Bradford White #M-1-10OTi 1 Large Gas All Pipes Ins 85,000 100 0.80 0.00% 0.0 , New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length (ft)o a a — System Name 7Lenth Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ ❑ Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-07-10709:29:05 ID: Page 5 of 5 Reg: 212-NO04962BA-000000000-0000 Registration Date/Time: 2012/09/07 12:44:33 HERS Provider: CalCERTS, Inc Electronically Filed-by-.Tim•.Scott.and-Authenticated-at-Ca10ERTSccom=- 9/7/2012-,, electronically Signed at Ca10ERTS.com by_Robin Leder`(Fedderly & Associates) 9/7/2012 PERFORMANCE CERTIFICATE: Residential Part 1 of '5 s i , Project Name Horn Residence PERFORMANCE CERTIFICATE: Residential Part 1 of '5 CF -1 R Project Name Horn Residence Building Type m Single Family ❑ Addition Alone 0 Multi Family ❑ Existing+ Addition/Alteration ' Date 9/7/2012 Project Address Lot 227 -The Hideaway. La Quinta California Energy Climate Zone CAClimate Zone 15 Total Gond. Floor Area 6,547 Addition , n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes 0 No HERS Measures -- If Yes, A CF -4R must be provided per Part -.2 of 5 of this form. El -Yes ❑ No Special, Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special ; Cavity(fi� Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 6,547 Radiant Barrier New. ; Wall Wood Framed . R-21 3,529 ( New Slab Unheated Slab -on -Grade* None 6,550 Perim = 563' _ New r. -Door. Opaque Door = None ' 48 ' rJ,� f l _ New nkNG_ ,-�� ON. Z y FENESTRATION ' U- Orientation Area(ft) Factor Cj ►Y Exterior SHGC Over an Si a in Y Status Front (N): 260.0 0.390 0.28 none . DA n Bug Screen New Front(NE) a 11.3 0.3901----,-9.28_4.0_1 �._.. ,,rnone , �9 Bu Screen New �.� Front (NEj; , 48.0 :# 0:390' 'O.28' ' X6:0 ` none,.` `Bug Screen1 . X New Front (NE)= 11 3 0.390 0. 28 'none nohe� I ; :Bug Screen, New Left (SE) e, , , 129 0 �� ., 0.390 0.28' , none ,�., noneBug Screen �, f�r;�,, j New ` Rear (SV1� ` <j 425.0 i f:r 0.390,`q• 0.28 `;-10.Of ; - F' .none;_ BugrScreenr°New Rear (SVIO 64.0 0.390 0.'2-8- 2.0 none Bug Screen New Rear (SVI9 11.3 0.390 • 0.28 4.0 , none Bug Screen New - Rear (SM 48.0 0.390 0.28 none none Bug Screen • . New Right (NM 14.0 0.390 0.28 6.0 none' Bug Screen New" Right (NV1) 15.0 0.390 0.28 none none Bug Screen New HVAC SYSTEMS ; ,Qty. Heating Min. Eff Cooling Min. Eff . Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New - HVAC DISTRIBUTION Location _ i Heating Duct Cooling -Duct Location R -Value Status - HVAC 1 Ducted ' Ducted Attic, Ceiling Ins, vented 8.0 - New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 Ducted Ducted . Attic, Ceiling Ins, vented 8.0 +- ''New WATER HEATING. Qty. Type Gallons Min. Eff Distribution Status 1 Large Gas i 100 0.80 All Pipes Ins New Ener Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2012-06-01 T08:23:58 - ID: Pae 1 of 8 Reg: 212-N0049627A-000000000-0000 Registration Date/Time: 2012/09/07 12:43:33 HERS Provider:.CalCERTS, Inc r- r Electronically,Filed by 'Tim Scott and Authenticated at Ca10ERTS.com 9/7/2012 Electronically Signed'at_Ca10ERTS.com by Robin .Lever (Fedderly &Associates) 9/7/2012 PERFORMANCE CERTIFICATE: Residential- Part 1 of 5 - CF -1 R Project Name ;. Horn Residence ' Building Type • m Single Family ❑ Addition Alone r ❑ Multi Family ❑Existing+ Addition/Alteration Date '9/7/2012 Project Address., • - Lot 227 -The Hideaway La Wnta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area . 6, 547. . Addition n/a # of Stories 1 FIELD INSPECTION -ENERGY CHECKLIST ' ❑ Yes ❑ No - HERS Measures -- If'Yes, A CF -4R must be provided per Part 2 of 5 of this form. 1. ❑ Yes ❑ No Special Features -- If Yes, see' -Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of'5 Status FENESTRATION U- -•� Exterior Orientation Area(ft`) ' Factor SHGC Overhang Sidefins Shades---,.- - Status Front (N) 240.0 0.390 0.28 2.0 none 'Bug Screen New ' Left (E) ,, 160.0�, none -,,,B g -Screen r r* ,• New Rear S tr ; - � . . • � "fir �' ( ) j� 600.0 0.390 ,f 0.28 16.0 ,none • I `Bug Screen.u• y New Rear(SW)' y` ,1.10.0 0.390 0.28 ` 66.0; none' Bug Screen�`� r; New Right(Vq ' e, 246;0' . 0.390 028' rnone,- }- none r Bug Screen y ` r,��+ rjtir�ar ,New; eFront (N;., LI�')n ne«ZBu < reen-.k +�+ _'6.3 0 . �_. Pr _ ... , r N` w Left (E) 19.5. . 0.390 n' 0 28 6.0 none Bug Screen New ' Left (E) 119.7 - 0.390 0.28 none none Bug Screen New Rear (S) 166.5 - 0.390 - 0.28 none none Bug Screen .."� ` New Right (w) 150.0 0.390 0.28 20.0 none . Bug Screen New Rear (S) ' - 80.0 0.390 0.28 4.0 ' none Bug Screen " �' ' New HVAC SYSTEMS 6ty. Heating Min..Eff Cooling' Min. Eff Thermostat 'Status • 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback }' New HVAC DISTRIBUTION Duct Location Heating -Cooling Duct Location RWalue Status" ~ HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New •. WATER HEATING Ot . Type - Gallons 'Min..Eff Distribution .'. ' " , Status ; Ener Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-06-01708:23:58 ID: Page 2 of 8' Reg: 212-N0049627A-000000000-0000 -Registration Date/Time: 2012/09/07 12:43:33 HERS Provider: CalCERTS, Inc- Electronically Filed by -Tim Scott and Authenticated`at CalCERTS.com y 9/7/2012 '..Electronically Signed at CalCERTS.com by Robin Lever (Fedderly & Associates) 9/7/2012 . PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Building Type 0 Single Family ❑ Addition Alone Date '• Horn Residence F ❑ Multi Family ❑ Existing+ Addition/Alteration 9/7/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency • determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford White #M-1-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details. " The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air Now requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 1,246.0 ff2 Covered Slab Floor, 3.500" thick at Master Bedroom _ HIGH MASS Design - Verify Thermal Mass_ 210.0 ff2 Exposed Slab Floor, 3.500" thick at Master Bedroom •. ' M , HIGH MASS Design - Verify Thermal Mass: 816.0 ff2 Covered Slab Floor, 3.500"thick at Office Workout Bedroom 2 - HIGH MASS Design --Verify Thermal Mass:, 1,110.0 N2 Exposed Slab Floor, 3.500" thick at Office Workout Bedroom 2 * . The HVAC System HVAC 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. µ HIGH MASS Design - Verify Thermal Mass: 108.0 N2 Covered Slab Floor, 3.500" thick at Great Room Kitchen Nook HIGH MASS Design - Verify Thermal Mass: 1,815.0 tt2 Exposed Slab Floor, 3.500" thick at Great Room Kitchen Nook. The HVAC System HVAC 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 858.0 ff2 Covered Slab Floor, 3.500" thick at Office Laundry Hallway HIGH MASS Design ' Verify Thermal Mass: 387:0'ft2 Exposed Slab Floor; 3.500 thick at Office Laundry Hallway; The Roof R-38 Roof(R.38.2x 12.16) include's credit for a Radiant Barrier that is Continuous: meeting eligibility and installation criteria as specified in Residential Appendix RA4:2:2: ' a. irk') HERS REQUIWRED VERIFICATION r _rr. , Items in this'section.require field testing'and/or'verification by,a certified'HERS,Rater. The inspector must receive a completed CF -4R form for each• of the measures listed below.for final to begiven' . The Cooling System Carrier 24APA760/58PH"110 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge ora Charge Indicator Display. R The HVAC System HVAC 1. incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA760/58PH'110 includes credit for a.13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required_ to verify that duct leakage meets the specified criteria. , - • The Cooling System Carrier 24APA760/58PH`110 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser The HVAC System HVAC 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. • The Cooling System Carrier 24ACA 736/58PH'090 includes credit for a 13.2 EER Condenser . A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. • ' , The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-06-01708:23:58 ID: Page 3 of 8 Reg: 212-N0049627A-000000000-0000 Registration Date/Time: 2012/09/07;12:43:33 HERS Provider: CalCERTS, Inc Electronically Filed by•Tim Scott and Authenticated at Ca10ERTS.com.- 9/7/20121' Electronically Signed at CalCERTS.com by Robin Lever (Fedderly & Associates) 9/7/2012 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R. Project Name Building Type m Single Family ❑ Addition Alone Date Horn Residence -❑ Multi Family ❑ Existing+ Additio n/Alte ration 9/7/2012 ANNUAL ENERGY USE SUMMARY + Standard Proposed Margin TDV kBtu/ft2- r Space Heating 3.94 5.67 -1.72 Space Cooling 52.10' 46.86 _5.24 Fans ` 10.34 - r 14.84 - -4.49 { "• t ' Domestic Hot Water 5.57 3.75 1.82 Pumps 0.00 0.00 0.00 r Totals 71.96 71.11 0.84 Percent Better Than Standard: 1.2 BUILDING. COMPLIES - HERS VERIFICATION REQUIRED Fenestration . Building Front Orientation: ,(N) 0 deg Ext. Walls/Roof Wall Area - Area Number of Dwelling Units: ,' 1.00 - - (N) 1,675 634 Fuel Available at Site:.. Natural Gas (E) 1,524,; 428 Raised Floor Area:. �; ' 0 (S), 1,830 ,. 1,205 Slab on Grade Area: `'. 4 6,550 • • (Wj ; 1,240' .425. Average Ceiling Height: 11.5. Roof 6,547 .'o Fenestration Average U -Factor: 0.39 TOTAL: 2,692 ' ' Average SHGC: 0.28. Fenestration/CFA Ratio: 41.1% REMARKS V . }n, [/i� STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed - to comply with Title 24, Parts 1 -the Administrative Regulations and Part 6 the Efficiency Standards of:the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. a Documentation Author Company - Scott Design and Title 24, 'Inc; - �''. �• Address 77-085 Michigan Drive j'. Name Tim Scott • ; 9/7/2012 City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780. Signed Date The individual with overall design responsibility hereby certifies that the proposed. building design represented in this set of construction documents is consistent with the other compliance forms and worksheets', with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, , duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.' Designer or Owner (per Business & Professions Code) Company Fedderly and Associates •, Address "'. , 38-747. Nopales Road Name Fedderly and Associates ' City/State/Zip Palm Desert, Ca 92253 Phone (760) 773-0875. Signed '.License # Date Ener Pro 5.1 by Ener Soft User Number 6712 RunCode: 201 2-06-01 708:23:58 ID: Page 4 of 8 Reg: 212-N0049627A-000000000-0000 Registration Date/Time: 2012/09/07 12:43;33' -HERS Provider: CalCERTS, Inc �;^ Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/7/2012 Electronically Signed at CalCERTS.com by Robin Lever (Fedderly & Associates) 9/7/2012 CERTIFICATE OF'COMPLIANCE: Residential. . •- (Part 4 of 5) • .- CF -1 R. Project Name Residence Building Type IOSingle Family ❑ Addition Alone . '❑MultiFamily •❑ Existing+Addition/Alteration/2012 7DateHorn OPAQUE SURFACE DETAILS - • �' SurfaceU- Insulation T' a Area Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix �• Tilt Status 4 .Location/Comments Roof 1,456 0.026 R-38 0 0 New 4.2.1-A9 - Master Bedroom Wall 60 0.069 R-21 0 90 New 4.3.1-A6 Master Bedroom Wall 269 0.069 R-21 45 90 New 4.3.1-A6 Master Bedroom Wall 180 0.069 R-21, 135 90 New 4.3.1-A6 Master Bedroom Wall - 292 0.069 R-21 225 .. 90 New 4.3.1-A6 Master Bedroom Wall 367 0.069 R-21 315 90 New 4.3.1-A6 .. Master Bedroom Slab 1,246 0.730 None 0 180 New 4.4.7 -Al Master Bedroom Slab 210 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Roof 1,926 0.026 R-38 0 0 New 4.2.1-A9 Office Workout Bedroom Wall . 210 0.069 R-21 - 0 90 New _ 4.3.1-A6 Office Workout Bedroom Wall 258 0.069 R-21 90 90 New 4.3.1-A6 Office Workout Bedroom Wall 171 0.069 R-21 135 90 New 4.3.1-A6 Office Workout Bedroom Wall 40 0.069 R-21 180 .90 New 4.3.1-A6. Office Workout Bedroom Wall 73 0.069 R-21 225 90 New 4.3.1-A6 Office Workout Bedroom Wall 352 0.069 R-21 270 90 New 14.3.1-A6 _ Office Workout Bedroom 2 Slab 816 0.730 None 0 480 New 4.4.7-A1 Office Workout Bedroom 2 FENESTRATION SURFACE DETAILS,. ID Type Area U -Factor,. SH C2 Azm Status Glazing Type - Location/Comments 1 Window 20.0 , 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Master Bedroom . 2 Window 11.3 0.390 NFRC 0.28 NFRC 45 New Dual non Metal Tinted Master Bedroom 3 Window 48.0 0.390 NFRC 0.28 NFRC 45 New Dual non Metal Tinted Master Bedroom , 4 Window 11.3 0.390 NFRC 0.28 NFRC 45 New Dual non Metal Tinted Master Bedroom 5 Window.,_ �: 15.0 . 0.390 NFRC _.0.28 NFRC-• .. _ _ 135 New ._:., _ Dual non Metal Tinted Master Bedroom 6 Window. J 75.0 -0.390 NFRC ,e ,.r ; 0.28 NFRC 135 New f... Dual non Metal Tinted i 1` Master Bedroom 7- Window 9.0 0.390 NFRC y 0.28 NFRC 135 New t Dual non Metal Tinted- ' Master Bedroom 8 Window 125.0 -%0.390 NFRC 0.28 NFRC • .1225 Newer . ,- Dual non Metal Tinted i ., Master Bedroom 9 Window 32.0 j 0.390 NFRC r 0.28 NFRC ,< v 225 New_ 4 Dual non Metal Tinted Master Bedroom,-, ' 10 Window A 132.0' - 0.390 NFRC - 1 0.28 NFRC a .225 New., Dual non Metal Tinted t Master Bedroom .11 Window, 1 i'3' ,r 0.390 NFRC. -, 0.28 'NFRC 7'";1225 New Dual non.. Metal Tinted 4.. ' Master Bedroom 12 Window 48.0 0.390 NFRC " "' 0.28 NFRC 225 New Dual non Metal Tinted Master Bedroom 13 Window -14.0 0.390 NFRC " 0.28 NFRC - 315 New Dual non Metal Tinted • * + Master Bedroom ,14 Window .• 15.0 0.390 NFRC, 0.28 NFRC 315 New Dual non Metal Tinted Master Bedroom 15 Window 36.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Office Workout Bedroom 2 16 Window 40.0 0.390 1 NFRC I 0.28 NFRC 0 New Dual non Metal Tinted Office Workout Bedroom 2 (1) U -Factor Type_• 116-A'-- Default Table from Standards, NFRC =Labeled Value 2 SHGC T e: 116-B = Default Table from Standards, NFRC = Labeled Value r - EXTERIOR SHADING DETAILS ID- Exterior Shade Type SHGC Window Ove hang Left Fin H t FWd Len H t LExt RExt Dist Len Ri hffin Hcit Dist Len H t 1 Bug Screen 0.76 ` 2- Bug Screen 0.76 4.5 2.5 4.0 0.1 4.0 4.0 3 Bug Screen 0.76 8.0 6.0 6.0 0.1 6.0 6.0 4 Bug Screen 0.76 5' Bug Screen 0.76 6. Bug Screen -0.76 '• 7 Bug Screen 0.76 - 8 Bug Screen_., 0.76 10.0 12.5 10.0 0.1 10.0 10.0 9 Bug Screen 0.76 8.0 4.0 2.0 '0. 1 2.0 2.0 ` 10 Bug Screen - 0.76 8.0 4.0 2.0 0.1 2.0 2.0 ` 11 Bug Screen 0.76 4.5 2.5 4.0 0.1 .4.0 4.0 - 12 Bug Screen 0.76 13 Bug Screen 0.76 3.5 4.0 6.0 0.1 6.0 6.0 14 Bug Screen 0.76 15 Bug Screen 0.76 16 JBug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-06-01 T08:23:58 ID: - Page 5 of 8 s- ` Reg:.212-N0049627A-000000000-0000 Registration Date'/Time: 2012/09/07 12:43:33 HERS Provider: Cal'CERTS, Inc, _' 1 -• •♦ , � �, � i Q- _ -- J ,i fir• •. • V y � 'Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/7/2012 - Electronically Signed at Ca10ERTS.com by Robin Lever (Fedderly & Associates) 9/7/2012 , CERTIFICATE OF COMPLIANCE: Residential (Part 4:of 5) CF -1 R Project Name Horn Residence Building Type m Single Family ❑ Addition Alone r ❑ Multi Family, ❑ Existing+ Addition/Alteration Date 9/7/2012 OPAQUE SURFACE DETAILS Surface U- . Insulation Joint Appendix , Type Area Factor Cavity Exterior Frame Interior Frame Aim Tilt Status 4'. Location/Comments Slab 1,110 0.730 None 0 180 New 4.4.7-A 1 Office Workout Bedroom . Roof 1,923 0.026 R-38 0 0 New 4.2.1-A9 ■ Great Room Kitchen Nook Wall 128 0.069 R-21 0 90 New 4.3.1-A6 Great Room Kitchen Nook Wall 119 0.069 R-21 90 90 New 4.3.1-A6 Great Room Kitchen Nook Wall ' -171 0.069 R-21 1801 90 1 New 4.3.1-A6 • Great Room Kitchen Nook Wall 96 0.069 R-21 270 90 New 4.3.1-A6 Great Room Kitchen Nook Slab 108 0.730 None 0 180 New 4.4.7-A 1-. Great Room Kitchen Nook Slab 1,815 0.730 None 0 180 New 4.4.7-A1 Great Room Kitchen Nook Roof 1,242 0.026 R-38 0 0 New 4.2.1-A9 : 1 Office Laundry Hallway Wall 350 •0.069 R-21 0 ' 90 New 4.3.1-A6 Office Laundry Hallway Door 24 _0.500 None 0 90 New 4.5.1-A4 Office Laundry Hallway . Wall 344 0.069 R-21 901 90 New 4.3.1-A6 Office Laundry Hallway Door 24 0.500 None 90 . 90 New 4.5.1-A4 Office Laundry Hallway•• Wall 50 • 0.069 R-21 180 90 New 4.3.1-A6 Office Laundry Hallway Slab -, 8581 0.730 1 None 0 180 New 4.4.7-A1 Office Laundry Hallway Slab 3871 0.730 1 None 0 180 New 4.4.7-A1 Office Laundry Hallway FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC2 Azm Status Glazing Type Location/Comments 17 Window 120.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Office Workout Bedroom 2 18 Window 120.0. 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Office Workout Bedroom 2 19 Window 80.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Office Workout Bedroom 2 20 Window 80.0 0.390 NFRC, 0.28 NFRC 90 New Dual non Metal Tinted Office Workout Bedroom 2 21 Window .- L_... 30.0 0.390 NFRC 0.28 NFRC . 135 New = Dual non Metal.Tinted Office Workout Bedroom 2 22 Window '300.0 0.390 NFRC„ ..- 0.28 NFRC 180 New t- -i Dual.non Metal Tinted' r` - V Office Workout Bedroom 2 . 23 Window 110.0 0.390 NFRC ;' is 0.28 NFRC., 225 New, t z Dual non Metal Tinted. " '' Office Workout Bedroom 2 ' 24 Window - 4.0 "0.390. NFRC, ' 0.28 NFRC -4270 New,:` .�- Dual non Metal Tinted i S._ . Office Workout Bedroom 2 -25 Window 80.0 0.390 NFRC 0.28 NFRC. _ # 270 New 1, v4 Dual non, Metal Tinted -.,S' c Office. Workout Bedroom 2 26 Window ! ;15.0 ,a: 0.39Q NFRC 1. 0.28 NFRC o 270 New., Dual non Metal Tinted Office, Workout, Bedroom 2 27 Window,. f k_9.0:--0.390 NFRC, - 0.28 NFRC f270 New >- Dual non Metal Tinted Office Workout Bedroom 2 ' 28 Window 63.0 . 0.390 NFRC '" 0.28 NFRC` 0 New Dual non Metal Tinted :Great Room Kitchen Nook 29 Window ' • 43.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Great Room Kitchen Nook 30 Window . 95.0 0.390 NFRC 0.28 NFRC 0 New - Dual non Metal Tinted Great Room Kitchen Nook '31 Window 19.5 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Great Room Kitchen Nook 32 Window 18.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Great Room Kitchen Nook (1) , LI -Factor Type: 116-A =Default Table from Standards, NFRC = Labeled,Value . 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value - EXTERIOR SHADING DETAILS ID - ' Exterior Shade Type SHGC Window H t I Wd Ove hanq Left Fin Len H t - LExt RExt Dist • Len Ri ht Fin H t. Dist Len H t 17 Bug Screen 0.76 10.01 12.0 2.0 0.1 "2.0 2.0 18 Bug Screen • 0.76 10.0 12.0 2.0 0.1 2.0 2.0 - 19 Bug Screen ' 0.76 8.0 10.0 2.0 0.1 2.0 2.0 20 Bug Screen 0.76 8.0 10.0 2.0 0.1 2.0 2.0 �• 21 Bug Screen 0.76 t. 22 Bug Screen 0.76 10.0 30.0 16.0 0.1 16.0 16.0 23 Bug Screen -0.76 10.0 11.0 6.0 0.1 6.0 6.0 i 24 Bug Screen 0.76 << 25 Bug Screen 0.76 26 Bug Screen 0.76 = 27 ' Bug Screen 0.76 28 Bug Screen 0.76 9.0 7.0 6.0 0.1 6.0 6.0 29 Bug Screen '0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 8.0 -3.0 6.0 0.1 6.0 6.0 32 Bug Screen 0.76 ` Ener Pro 5.1 by Ener Soft User Number.' 6712 RunCode: 2012-06-01 T08:23:58 ID.' Page 6 of 8 Reg: 212-N0049627A-000000000-0000 Registration Date/Time: 2012/09/07 12:43:33 HERS Provider: CalCERTS,'Inc , Electronically Filed by Tim Scott and Authenticated at CalCERTS.com.- 9/7/2012 Electronically Signed at CalCERTS-com by Robin Lever (Fedderly & Associates) -9/7/2012 4. CERTIFICATEOF COMPLIANCE: - Residential _ (Part 4 of 5) CF -1 R Project Name Horn Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date g/712012 OPAQUE SURFACE DETAILS, Surface U-• -Type. Area Factor Insulation = Joint Appendix Cavity Exterior Frame Interior Frame Azm . Tilt Status 4 Location/Comments k FENESTRATION SURFACE DETAILS ID Type Area U -Factor SH C2 Azm Status Glazing Type Location/Comments 33 Window " 58.5 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Great Room Kitchen Nook . 34 Window 108.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Great Room Kitchen Nook 35 Window 300.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Great Room Kitchen Nook 36 Window 150.0 0.390 NFRC 0.28 NFRC 270 New • Dual non Metal Tinted Great Room Kitchen Nook 37 ' Window_ .. -. 43.0 0.390 NFRC 0.28 NFRC- __ ._ _1 .270 New. __Dual non Metal Tinted 4.t_ Great Room Kitchen Nook 38 Window", ; 95.0 0.390 NFRC ., 0.28 NFRC 270 New±;. ;.. Dual non Metal Tinted d r' Great Room Kitchen Nook • 39 Window '26.0 0.390 NFRC r' " 0.28 NFRC 0 New v Dual non Metal Tinted s * Office Laundry Hallway 40 Window 46.4• :,'0.390. NFRC 0.28 NFRC +! 90 New Dual non Metal Tinted '. Office Laundry Hallway 41 Window, 18.0 '10:390 NFRC 0.28 NFRC; r V 90 New,;, Dual non Metal Tinted .. Office, Laundry Hallway, 42 Window ri J1 1.3 ; 0.390 NFRC ! 0.28 NFRC l 190 'New y $ Dual non Metal Tinted i Office Laundry Hallway 43 Windowe. X26.6 0.390 NFRC, '` X0.28 NFRC'-.1 !-:_.I c90 New '-.Dual non Metal Tinted i,z% Office Laundry. Hallway 44 Window 80.0 -0.396 NFRC 0.28 NFRC180 New Dual non Metal Tinted Office Laundry Hallway (1) U -Factor Type: 2 SHGC Type: - 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC =' Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t . Wd Ove hang Left Fin Len H t LExt -RExt Dist Len Right Fin ' H t - 'Dist ..Len H t• 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 10.0 30.0 16.0 0.1 16.0 16.0 36 Bug Screen 0.76 10.0 15.0 20.0 - 0.1 20.0 10.0 37• Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 • Bug Screen . 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 10.0 8.0 4.0 0.1 -4.0 4.0 EnergyPro5lbyEnergySoft User Number: 6712 RunCode: 2012-06-01 T08:23:58 /D: - Pae 7 of 8 Reg:'212-N0049627A-000000000-0000 'Registration Date/Time:'2012/09/07 12:43:33 HERS Provider: CalCERTS,-Inc Electronically.Filed by -Tim Scott and Authenticated at CalCERTS.com•- 9/7/2012 Electronically Signed at CalCERTS.com by -Robin Lever (Fedderly & Associates) 9/7/2012 CERTIFICATE OF COMPLIANCE: Residential' � (Part' 5 of 5) CF -1 R Project Name _ Horn Residence Building Type '❑ Single Family ❑ Addition Alone . • "❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/7/2012 BUILDING ZONE INFORMATION' ' System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built HVAC 1 Master Bedroom 1,456 14,560 HVAC 2 Office Workout Bedroom 2 1,926 23,112 HVAC 3 Great Room Kitchen Nook 1,923 24,999 HVAC 4 Office Laundry Hallway 1,242 12,420 - Totals 6,5471 0 0 0 t + HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type. Min. Eff. Thermostat Type Status HVAC 1 .. 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New ' HVAC 2 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New ' HVAC 3 : , r 1 Central Furnace 80% AFUE Split Air.Conditionerx . 16:5 SEER Setback New HVAC 4 i' 1 ; Central Furnace " 86%'AFUE Split'Air�Coriditioner > 16.5 SEER Setback New . fir, ,sTM• iC J ` .' HVAC DISTRIBUTION " -1 f` 1 A .4 f f J A I-i.`!t Sys . tem Name •Heatin 7'x.5, DuctL_ Ducts-= C 'Cooling Duct Location R -Value ,Tested? Status HVAC.1 - Ducted Ducted Attic, Ceiling Ins, vented 8.0 10 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 3 Ducted . Ducted - Attic, Ceiling Ins, vented 1 8.01 0 New HVAC 4 , Ducted Ducted Attic, Ceiling Ins, vented 8.0 0 New - r WATER HEATING SYSTEMS - o Sstem Name Qty. Type "r Distribution _ Rated Input Btuh Tank Cap. al Energy Factor or RE 'Standby Loss or Pilot Ext. Tank . Insul. R- Value Status Bradford White #M -1-100T I. Large Gas All Pipes Ins 85,000 .100 0.80 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDROPIC HEATING SYSTEM PIPING r Control'- Hot Water Piping Length 16 --0 u) a - S stem Name ' Pipe Length , Pipe Dia'meter Insul. Thick. r Q . HP ' Plenum Outside Buried Ener Pro 5.1 by Ener Sof User Number: 6712 RunCode: 2012-06-01 T08:23:58 ID: Pa e 8 of 8 Reg:•212-N0049627A-000000000-0000 Registration Date/Time: 2012/09/07.12:43:33 HERS Provider: Ca10ERTS, Inc i.- ` �• "� r y it • ''_+j�• � � •+ { ' January 10, 2013 Project: Horn - Lot 227 at 53804 Via Palacio t RE: Horn Residence Submittal Below please see list of modifications to exterior glazing for DRC review and approval. 1) Bedroom 3: We have changed the French Doors to Sliding Doors to match sliders in Living Room which are on same elevation. 2) Living Room: We have changed the Pocket Sliders to Standard Sliders.- In doing so this, the system will now be a 3 unit sliding door system. 3) Bedroom 4: We have, changed the French Doors to Sliding Doors to match the other sliders in the Guest Casita for uniformity. 4) Powder Room: Existing Full Height Feature Window has been modified to now be 54" high. We have done this to provide us with enough wall space below for the installation of plumbing within the Powder Room. 5) His Closet: We have added a Window as shown in Section 4 in order to . provide more natural light into the closet. 6) Master Bath: We have changed doors in Master Bath to Courtyard from Sliding Doors to French Doors as we feel it is more appropriate for this application. Please reference enclosed drawings addressing all items noted above. Feel free to contact us should you have any questions and/or comments. Thank you for your attention. Lance Fedderly Fedderly & Associates JAN 112013 a A GUEST HOUSE REVISION : - =SCALE: 1/4"=1'-0" ISSUED: 01/14/13 • - a. T . 'V: ♦ , a f {. iJi' .. +Y T r N .. rf r • r ®F L` weOl r.pEpT,' ,.3UILDING & SAFETY f ' . - ,-^ r •'•- _ _. - '_ •- � ^ - - '- _ ;fir' .. '4 TRUCTION OR CONVED S ; k 'r c14 .. t TOP• OF CHIM t _ + _ V r—. ., _ ^ + i + - , .. .y • - . ' „ J (� . Lam"-. K, EIi TOP OF STRUCTURE . I - __) — r li �JN TOP OF STRUCTURE /w/• - o p;Iftli !!III ;ii ;!illi q;l; '� - �� + •'a o w 1 Z , LLJ z j • _ _' _� �� .. - .- s •'* .-%, O-�__-� . � \� ���_\;1111' .'- � •�- � - � � , CD CL NIM I MM as I am-mr- X CD mill Jig + • - - • - - J _ O ..4 t,'.7 u.,„2ri1 '.. 'SQ ♦ t O .d �7PlY�. Y- i- - , r^ - MEW TOP OF SLAB --c ,- x w .„ `CD TOP 0 SLAB o M -. � o 3 _ LIVING - - BDRM.3 . $o ELEVATION B ^ • y rry w ^., s c• .. 3 z'' ..: r,.a,1,, ' - f, i S..ir., ,,. r .. - '. s.. - ;Y' .-1� i' _ .�..�ro�fr. -i ,w �'� - - t t a .,t � •w . d'- •i y{y - 1 �. i t t T •+S_' 4 C 44 T- ^, ' )_-�{ +•' •- - .E' K 't��, « Y ' O 16 a 05 v NO • •+ a y. - `:F 'r. r' z .- ±. :�:• ^ r a' t ',y''}'{ - - .. L- + •1"a; ,,�'i .. r a '�_�'.'Z''i'�� F ,twi,�dp - , 7 :. •ri - 'f i•g •• _ _ 'F. - 'l'['Fa4 x - - , .I Pd,R.{tj_ _ ^Ef. t - _ `t= Z', - M' 1,y' �. 'r r.•". .+-1 r•' ' - • :q,r •. y„ "' _ + j V ' '♦ . - ,, •.-;'j.y..t: ar ♦ .� - - _ _ t^.._, mss: V� .. � ,q - .,�. :r 1L. a , :, : _ . _ • y - . .. �3� a L r. � .� . N � 'P_ t.'�' d+cr i . f ,O• `«� EA�`'.� . L.. - .- �, "'� :�� + . • . \411_11_OII + - 44 r S GUEST HOUSEREVISION� °SCALE. 1/ r.i ,:- ... _ _ a. .•�...3 ti. - - _ ,•. ^. r. .w M-.. .. _,t .. --1. ..r .• �+ tt-v -• �-.'^y. v i_ ' i..4 t '. , , .. _. C � • • � � � �� .ISSUED: 01/14/13 '° r � .,. s �(' •+�•� w , .� b,c, '.`� i E,.•µ4,. .- - .f � ;. l �}'yi ° - .,�. � y e _ \ � ��,7��, a•. .Tt+; .�.. , r �.ei .'7 y �r'1 .�� ,zpt, r.•. •F .r . " �� � �'BUiLMNG & SkFE rY UEPT. FOR CONSTRUCTION DATE? BY - .,TOP OF CHIM • ..•. y , T X �.. �.. tr \ " f.° 1 ,.` .. r` - r F? 2 r O • -a .. : LLO C� c TOP OF STRUCTURE ' d TOP OF STRUCTUREcl • ., r - O r 5 F••••1 U Q cz il'' 'lily' i111i ill.'cn . P > -nll a� z , - -_ CD 3rdk 1 - tib JF =cD C D/ zz 73c)[ 1p CD w I(-5 DUE 0, j( 0 to ,x`• r _J jc01 - BDRM 4 LIVING =0$M' i r.� ELEVATION D �, • N Viz - , " ° , - r l; E x co ce LE • _ ,. ' � Y•t.- i. ,. •.r' }.• t� i ,'w •` • . ��� r - r a: •. 1 :. .•- F..� ' .T i y �jW lg— µ bU�, X06 '� .. • v r ' f •` r' ' , .. y - a ;ft' z K 'f {p: r ti �. r , + • 7 + , , ' N •O XN cj me C'n C13 G'i LL of r O -Tz$ �+ RS XN cj me C'n C13 " CN C%q +ol 4 �P CA�: .0 ko p�p C) co +PG \ t� . ^ ob XLP _ ' ;{ � Nye '` +�! _ _ .. ia•7 �' _ ` � _� _ _ . .. ' - r . rw,}4�-M _1' _ � •'+, • -MwA- .. •4 r V x ,t,W �, Y.!'. e+e.i..C7 • a'it'! M. - '• • • '�' � - r:T ♦. . U . . x w�rF :1 '• h• 4 - _ -,• � � .. . � } .S F! �,♦ .i 'f J'- � t. • .- � w �' V•'� ' „•�^''� ��.!4. ••�. , r1 �. c - + • i " �' +�-. .�' �i'-•^ X +-' I .1 ,l'` +. � it rt - •1 ,. - r .••i., - - MASTER BATH �Y• �'� , �= SCALE:a 1/4it_1 —-011 2 _ ISSUED: 01/14/13 ''-: ' � . �.,� ,;,, --. -� ,_ . *" �{� • s � , • •^ '.��air.. yxs., 1 t4 r•. as-Fx' , n . err. ' . • �';; r _ _ � a _ �y , c�"�'' 3� _' it �.! .. ! 70.' M i � r � r � • ¢ { � • � • F 4 � • � - - F � } � J � � � jj�eit � • > h,•. , � •s �„_' i~ti .i.0 h 4� :� - _ � f '� '1V + � � � , Je 10 4 [oz- - lil'. czs - •-r ra. 03 ce •� � i � — ;-•==� 6111 I!!1 !if!! SO FIT y 911ii 91111 911U I!li' 4!'d ll�_IP_ lid 00 _ Affl"�, ' :rc IW I PZ mlo MAS.BDRM' MAS -BAT _ CART -GARAGE . a oM r � ' ELEVATION K _ .♦ r, .; i _ ,` ... ' _ .. � , _ _ i - , - + - ,'c y •- � .fig' O -"'?' cn it 0 02 1,': •. _ r'" ` ; .- }' t,!! • .. s r.t - +r - .! «...y '�• l - � r cJr: �. - .. r��'' r.� y , « - r " . ` x •.� r-"�. r y -f ` `.>.' ,�' y • ♦ O ��a ` ^ +,4 ... ''.`" • - - �wv �^ vrx-' L�'- s - ` 'n,•=.�{�• :F r .0 1' d , -^ `i+" k+ .. •) ` _ ,. �- - - - F •^+=- y.'� -ta: - .'�►O oo ' _ .i. ; - . � � - �,• � r lam.,.. 7' Z wn`.f :.e "_ ,..{ .,..moi f � ' a '� .. .ti#' " - „ A, - ._ { '��.: �` M {',,. � • 't� ,t , , a a ` -_: ? •. y '. `.,. '.r• `yam � '^ iS _ ... i -. _ � _ - F•�� ? w'.� ! . h♦ w .` i_4k - ry• , _ , , r' A. •.r . . •.i'1•. -. - - ^ , 1 , - - •A1 r �' e• r Nye '` Vx � - l '•. 1 N 1 2 [oz- - lil'. czs - •-r ra. 03 ce •� � i � — ;-•==� 6111 I!!1 !if!! SO FIT y 911ii 91111 911U I!li' 4!'d ll�_IP_ lid 00 _ Affl"�, ' :rc IW I PZ mlo MAS.BDRM' MAS -BAT _ CART -GARAGE . a oM r � ' ELEVATION K _ .♦ r, .; i _ ,` ... ' _ .. � , _ _ i - , - + - ,'c y •- � .fig' O -"'?' cn it 0 02 1,': •. _ r'" ` ; .- }' t,!! • .. s r.t - +r - .! «...y '�• l - � r cJr: �. - .. r��'' r.� y , « - r " . ` x •.� r-"�. r y -f ` `.>.' ,�' y • ♦ O ��a ` ^ +,4 ... ''.`" • - - �wv �^ vrx-' L�'- s - ` 'n,•=.�{�• :F r .0 1' d , -^ `i+" k+ .. •) ` _ ,. �- - - - F •^+=- y.'� -ta: - .'�►O oo ' _ .i. ; - . � � - �,• � r lam.,.. 7' Z wn`.f :.e "_ ,..{ .,..moi f � ' a '� .. .ti#' " - „ A, - ._ { '��.: �` M {',,. � • 't� ,t , , a a ` -_: ? •. y '. `.,. '.r• `yam � '^ iS _ ... i -. _ � _ - F•�� ? w'.� ! . h♦ w .` i_4k - ry• , _ , , r' A. •.r . . •.i'1•. -. - - ^ , 1 , - - •A1 r �' e• r ° ` `•- .kms _ -; .: r "� r..' � `�x# • . _ < t,. _ St i''t �. . y. r�.'�i�y4. r a �„ ��et:. �.«J. .-- .. �. ;y! a '1'.r ,.- - - .. � .q ,;.{ y `r. a�--x'' A �G'.. a'.. i- �• ♦i POWDERROOIVI 'SCALE: `1/4"-1.-0 _ I. - �-�a• _ _'• . _: :-... • ..:.. �� � - ;<- - .�•�. _ .. _ ._ � °.�=�: ISSUED: 01/14/13 `.....�+. c ,�.� S -` �`•s . , ...... - I .."M^IE si r� ._ . -u. ' .. A� :. . .-,�. _ '. H r R , ' . r ,•. , - .xy :-•'� +. , .. _^ , - _ 1i -. Y, �•: _ .\._ _ �/ w s / . � � � • ' e .. 1.. - -« - ' i' r' .ws viz _ _ - __ -- _ {- .. -'Z-7 • - '. 11 + .f .. V' .. . f •P"�' . . ice- T -, �- - - ti ., a C � 3 •{. y> ,... •' r }}��,,,,,, ' ... - � >~, � r rS �. ,�,, � { :'. r r. i. �� fir. . I , .�/_` CITY ®F'LA QUINTA . q BUILDING & SAFETY DEPT" < - 41 OWDER ' _ — A���®V a N Z L4 t. FOR CONSTRUCTION,rn o _ a , • N N .DATE By 40, 03 i• .� - 'x -mays r - y .1 •.♦ .� •..r y !•tet N' �. .� STUCCO FINISH03 - _ STONE PROFILE�AT PARAPET' cz w o _ _ "T> DECORATIVE MEDALLION T' Z o .. T .,WOOD -HEADER' STONE VENEER a - oo : TOP OF STRUCTURE • f re• - M A. TOP OF_STRUCTURE. 4 — y PIA ell pll� I�JC • . a .� !Ilu - -n�_ , , -" - - - �• - -- — ^SIL ll� . t. C Cie a y: j > r f r•. • r, -i.• ::.,haw", w i� '@ s:.t S� — _JI �� I II����11 I I��II�I ��� .I I (� III ilt_I. co o `. - .' • x -- _ -} r4V, I i� rl I^ +^ II Ili.11ll• iV ,. IV,I •il . Z � � f Aar. .S - • i ♦ r 4 I , - r. . �'..�} �_ t J�� _J Y •F !) I ) f, I i I �I I J .. /� 'II III I 11111 �1 W x LE i J, 1 i�l i �i.—��- moi.- i�► (t111,, I�t�i �I����III►IIN�I�� III?tl �llf,il�uo Nz x% - _ Y —� _ -- - _- s _ � i�Ii��ii c� 1ili�« � �ii,l IIS Ili �i���. �iil I lil�ili ��� ��I�� i1 I . � iiliii�i���� �i►ii�� � _ cv •} j �' K Yf POWDER GARAGE 2, 2 •LAUNDRY r r i F =x w ELEVATION -B= . x` �� a � c' - e ' r � " y:a" T�•A' h 4.} ...,ti• •i.•�*' �' Y.� . _. `j" x.:, •, � � ,... .r { � •y4 . +t C r 'q .. Y .L ry.+.\ / ��fy,.> f• r!, �-•� - ".{� . !'G�� • - ' f r 'A.. • R..�. ,T� _ _ - HIS CLOSET. `.F SCALE: 1/4"=1'-0" ISSUED: 01/14/13 CITY OF LA QUINTA N tAlys I HIS CLOSET. `.F SCALE: 1/4"=1'-0" ISSUED: 01/14/13 CITY OF LA QUINTA N BUILDING & SAFETY DEPT. APPROVED" M FOR CONSTRUCTION 0 DATE' BY E C -41 �a 4 N. owa. c4 _ SQCJ. �C13 oc0 o cn m LZ Z o • O 00 - TRANSOM ICC -ES Evaluation Report ESR -1757 Reissued March 1, 2011 This report is subject. to renewal in two years. wwwAcc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 18 13—Pedestrian Traffic Coatings REPORT HOLDER: 4 CROSSFIELD PRODUCTS CORP. 3000 EAST HARCOURT STREET RANCHO DOMINGUEZ, CALIFORNIA 90221 (310) 886-9100 www.dexotex.com lamd(&cpcmail.net EVALUATION SUBJECT: ' DEX-O-TEX.WEATHERWEAR ROOF DECK COVERING • 1.0 EVALUATION SCOPE j Compliance with the following codes: `■ 2009 International Building Codee (2009 IBC) ■ 2009 International Residential Codee (2009 IRC) ■ 2006 International Building Codee (2006 IBC) ■ 2006 International Residential Codee (2006 IRC) ■ 1997 Uniform Building Code TM (UBC) Properties evaluated: ■ Durability ■ Wind resistance ■ Fire classification ■ Fire resistance 2.0 USES Dex-O-Tex Weatherwear Roof Deck Covering is a walking deck and Class A roof system for. use over plywood, steel or concrete decks. The system is also used as a component of a one-hour fire -resistance -rated roof assembly. 3.0 DESCRIPTION Dex-O-Tex, Weatherwear roof deck covering is a multilayered, trowel -applied, waterproof roof coating that is subjected only to normal foot traffic. The system consists of a series of troweled coatings that form, successively, an elastic latex membrane, an integral composition flashing, and a flexible rubber cement traffic surface, made of Resistite paste, Resistite powder, Neobond II membrane liquid, N-38 paste, and Standard Neotex powder. A base r. sheet separates the Dex-O-Tex application from the t surface, it covers, permitting it to "float" over normal building cracks and movement. Dex-O-Tex Weatherwear components are all combinations of liquid rubber latex polymers incorporating dehydrating powders, vulcanizers, and special aggregates. The total thickness of the material is 3/16 inch to /4 inch (4.8 mm to 6.4 mm). 4 4.0INSTALLATION 4.1 General: Installation of the Dex-O-Tex Weatherwear must be in accordance with the manufacturer's published installation instructions, the applicable code and this report. The manufacturer's installation instructions must be available on the jobsite during application.. Liquid components have ' a shelf life of one year and must be stored at temperatures above'32°F (0°C). The system must be installed only when the ambient temperature is above 32°F (0°C). Materials must not 'be applied if precipitation is occurring or expected. 4.2 Preparation of Substrates:, Structurally sound, clean, dry substrates listed above must be prepared, as described below, prior to the application of the finish material. 4.2.1 Structural Concrete: The surfaces must be clean and free of standing water. All holes, joints and cracks must be pointed flush with portland cement mortar, and all high spots cut or ground off to provide a smooth, even surface. Before the material is applied, the substrate must be carefully swept, or blown clean by high-pressure air to remove all dust or foreign material. Special care must be taken in the preparation and cleaning of all corners and edges. Foreign materials such as paint, grease and oil must be removed by either grinding or sandblasting, with new concrete surfaces acid -etched. Large areas to be covered are required to have control joints at maximum intervals not to exceed 20 feet (6096 mm) on center, with the control joint system worked out to meet all known deck stress -concentration points. The control joints must be cut in the same manner as for standard concrete construction, and then caulked." '4.2.2 Plywood Base Material: Plywood substrates must be. minimum 5/8 -inch -thick '(15.9 mm) exterior -grade plywood, having a maximum span of 16 inches (406 mm), and with tongue -arid -groove edges and ends blocked or all edges blocked, and face grain perpendicular to supports. The plywood -must be supported along all edges, and adequately fastened to all `bearings by means of countersunk wood screws, or screw nails equivalent to 8d ring shank nails spaced at 6 inches (152 mm) on center, or as otherwise required by the applicable code. The nails 1CC-p.5• L•1•aluation Reports are not to be construed as representing aesthetics or any other auributes not specifically addressed, nor are they to be construed ^a as an endorsement of the suhject of the report or a recommendation for its use. There is no warranty by ICC Ernluation Seri -ice. /_1,C., express or inhplied,•as L. to anyJinding or other matter in this report, or as to any product covered by the report. m.. - Copyright © 2011_ Page 1 of 3 4 i ESR -1757 I Most Widely Accepted and Trusted Page 2 of 3 must have a minimum penetration into the beams or joists supporting the plywood as required by the applicable code. The plywood surface must be clean, dry and free of all foreign materials such as paint, grease, oil and dust. Cracks in the plywood and all panel butt joints are to be sealed using a caulking compound. 4.2.3 Steel: Steel' surfaces, having sufficient rigidity to avoid excessive deflections or being solidly backed by a rigid substrate, must be cleaned of all dust, grease, oil, silicone, loose paint, etc. The surface must be sufficiently roughened to assure a good bond by sanding, grinding, etc., and the resultant dust must be carefully removed. 4.3 Class A Roof Covering over Plywood Deck: a. The plywood is described and installed as set forth in Section 4.2.2, at a maximum slope of /4:12 (2.1%). Plywood panel joints must be filled with joint compound consisting of one part Resistite paste to three parts Resistite powder, mixed by weight. Total minimum thickness is 9/32 inch (7.1 mm). b. One layer of Type IV, asphalt -coated, fiberglass base sheet complying with ASTM D 2178 must be applied to the plywood. The sheets must be nominally 36 inches (919 mm) wide by 56 yards (51.2 m) long and must weigh a minimum of 10.5 pounds per 100 square feet (0.5 kg/m?). The base sheet must terminate 2 inches (51 mm) from the perimeter, protrusions and other flashing areas, and must be lapped 2 inches (51 mm) at joints. c. Metal flashing must not be less than 0.019 -inch (0.48 mm) (No. 26 galvanized sheet gage) corrosion - resistant .steel and must be degreased before installation. The base sheet must lap over the horizontal flange of installed vents. d. A mixture of one part Resistite paste and 2.25 parts Resistite powder, by weight, must be applied to all exposed surfaces -and extend 4 inches (102 mm) onto the adjacent base sheet. Coverage must be a minimum of 19 pounds per 100 square feet (0.9 kg/m2). e. Perimeter and flashing areas must receive a coating of Neobond II membrane liquid at a minimum rate of 30 pounds per 100 square feet (1.5 kg/m2). Loose -woven jute fabric, nominally 0.035 inch (0.9 mm) thick and weighing 7 ounces per square yard (237 g/m2), must be embedded into the wet Neobond II. The combined thickness of Neobond It and fabric must be approximately 0.07 inch (1.8 mm). Each coating must be dry (this normally requires 12 to 16 hours) before recoating. f. Flat (field) areas must receive a coat of Neobond II membrane liquid at a rate of 21 pounds per square (1 kg/m2). Random strands of fiberglass mat, weighing 1/4 ounce per square foot (76 g/m2j, must be, embedded into the wet Neobond II. The combined thickness of Neobond II and fiberglass must be approximately 0.050 inch (1.3 mm). Each coating must be dry (this normally requires 12 to 16 hours) before recoating. g. An additional coat of Neobond II is applied, to fill voids in the jute and fiberglass fabrics, at the .rate, respectively, of 6 pounds and 5 pounds per square foot (29 kg /M2 and 24 kg/m2). Thickness of the membrane system must be 0.085 inch (2.1 mm) at perimeter and flashing areas and 0.062 inch (1.6 mm) in the field area. About six hours are needed for cure. h. A mixture of one part N-38 paste and five parts Standard Neotex powder, by weight, must cover the surface at a rate of 80 pounds per 100 square feet (3.9 kg/m2). The approximate dry thickness must be 0.090 inch (2.3 mm). After curing for a minimum of 12 hours, a second application at a rate of 52 pounds per 100 square feet (2.5 kg /M2) yields a dry thickness of 0.060 -inch (1.5 mm). The total application is 132 pounds per 100 square feet (6.4 kg/m ), for a total dry thickness of 0.150 inch (3.8 mm). i. After the Standard Neotex has cured for a minimum of 12 hours, a topping mixture of one part Resistite paste and 2.75 parts Resistite powder, by weight, must be troweled on at a rate of 18.5 pounds per 100 square feet(0.9 kg /M2), yielding a minimum dry thickness of 0.016 inch (0.4 mm). After curing to a dry state for a minimum of three hours, another topping is applied using one part Resistite paste to 2.1 parts Resistite powder, at a rate of 12 pounds per 100 square. feet (0.6 kg /M2), yielding a minimum dry thickness of 0.010 inch (0.25 mm). Total topping application must yield a minimum dry thickness of 0.028 inch (0.71 mm). j. After the topping application has cured to a dry state for a minimum of three hours, two coats of AJ -44 dressing must be roller -applied, at a rate of 150 square feet per gallon (3.7 M2 /Q, yielding a minimum dry thickness of 0.005 inch (0.13 mm). The first coat must be cured dry (this normally requires two to four hours) before application of the second coat. Total thickness of Items a through j of Section 4.3, excluding base sheet and perimeter/flashing bond coating, must be a minimum 0.245 inch•(6.2 mm) at flat areas and 0.268 inch (6.8 mm) at perimeter areas. 4.4 Class A Roof Covering over Concrete and Steel Decks: The roof deck must be concrete or steel prepared as noted in Section 4.2 of this report, with a minimum slope Of (4%). For concrete substrates, the base sheet must be bonded to metal flashing at the perimeter. For steel decks, the base sheet is optional. If a base sheet is used on steel decks, it must be bonded directly to the steel deck at the perimeter or installed with a metal flashing as for the concrete surface. The roof covering must be installed in accordance with items b through j, of Section 4.3, above. 4.5 One-hour Fire -resistance -rated Construction: The Dex-O-Tex Weatherwear Roof Deck covering installed as described in this report over 5/8 -inch -thick (15.9 mm) exterior -grade plywood with 2 -inch -by -8 -inch (51 mm by 203 mm) joists spaced 16 inches (406 mm) on center, with all plywood joints blocked, may be substituted for the double wood floor described in Footnote 13 of Table 7-C of the UBC and Table 720.1(3) footnote m of the IBC. When installation is over nominally 2 -by -8 joists, the design bending stress assigned to the joists must be limited to 78 percent of the code -prescribed design values. 5.0 CONDITIONS OF USE The Dex-O-Tex Weatherwear Roof Deck Covering described in ,this report complies with, or is a suitable alternative to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Materials must be manufactured and applied in accordance with this report and the manufacturer's instructions. In the event of conflict between this report and the manufacturer's installation instructions, this report must govern. 5.2 Applications must be by applicators authorized 'by Crossfield Products. ESR -1757 I Most Widely Accepted and Trusted Page 3 of 3 5.3 Fire classification must be as described in Sections 6.2 Reports of.reduced-scale fire -resistive -rated assembly 4.3 and 4.4. tests. 5.4 Installation must be limited to buildings a maximum of 7.0 IDENTIFICATION 90 feet (27.4 m) above grade, in areas with a All containers, except for those of the'fiberglass base sheet maximum 3 -second -gust basic wind speed of 100 and loose woven jute fabric, are identified with the - miles per hour (44 m/s) [fastest -mile basic wind speed report holders name and the manufacturing address, the of 80 miles per hour (129 km/h)], Exposure B. product name, the date of manufacture, the shelf life and 5.5 Materials are manufactured by Crossfied Products the lot number or production number. In addition to the Corporation, in Rancho Dominguez, California, under above, the materials listed in this report are identified with a quality control program with inspections by .the ICC -ES report number (ESR -1757) and the name of RI Ogawa & Associates, Inc. (AA -705). -the' inspection agency (RI Ogawa & Associates, Inc., 6.0 EVIDENCE SUBMITTED AA -705). 6.1 Data in accordance with the ICC -ES Acceptance Criteria for Walking Decks (AC39), dated February :. 2010. 1. Sladden Engineering 45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 a 6782 Stanton Avenue, Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont,.CA 92223 (951) 845-7743 Fax (951) 845-8863 800 E. Florida Avenue, Hemet, CA 92543 (951) 766-8777 Fax (951) 766-8778 August 17, 2012 Project No. 544-12079 12-08-207 Mr. & Mrs. Horn c/o Fedderly & Associates 38-747 Nopales Road Palm Desert, California 92211 Project: Proposed Horn Residence 53804 Via Palacio The Hideaway La Quinta, California ' Subject: Geotechnical Update Ref: Geotechnical Update prepared by Sladden Engineering dated October 26, 2009; Project . No. 544-09165, Report No. 09-10-258 Geotechnical Engineering Report prepared' by Earth Systems Southwest (ESSW) dated September 22, 2000; File No. 07117-10, Report No. 00-09-772 Report of Testing and Observation DuringRough Grading prepared .=by. ESS dated " August 28,2002; File No. 07117-11,. Report No. 01=07-718 -` Report 'of Testing and Observation During Rough Grading prepared by Sladden Engineering dated October 12, 2003; Project No. 544-2199 Report No. 03-10-647. As requested, we have reviewed the above referenced geotechnical reports as they relate to the - design and construction of the proposed custom residence. The project site is located at 53804 Via Palacio (Lot 227) within the Hideaway development in the City. of La Quinta, California. It is. 'our understanding that the proposed residence .will be a relatively lightweight wood -frame structure supported by conventional shallow spread footings and concrete slabs on grade. The.subject lot was previously graded during the rough grading of the Hideaway project site and was subsequently regraded. The rough grading included over -excavation of the native surface soil along with the placement of engineered fill soil to construct the building pad. The regrading included processing the surface soil along with minor cuts and fills to construct the individual building pads "to the current configurations. Some additional over -excavation was performed in areas where the building envelopes were reconfigured. The most recent site grading is summarized in ,the referenced :Report of Testing, and Observations During Rough Grading prepared by Sladden Engineering along with the compaction test results.. .D SEP i l 2012 . 'ay August 17, 2012 -2- Project No. 544-12079 12-08-207 Because the lot has been previously rough graded, the remedial grading required at .this time should be minimal provided that the building falls within the previously assumed building envelopes. The building area should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted to a minimum of 90 percent relative compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. The allowable bearing pressures. recommended in the referenced grading report prepared. by Sladden Engineering remain applicable. Conventional shallow spread footings should be. ' bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footings should be. designed utilizing allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf ' for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be utilized if desired. The maximum allowable, bearing pressure should be 3000 psf. The recommended allowable bearing pressures may be increased by one-third for wind and seismic loading. Lateral forces may be resisted by friction along the base of the foundations and passive resistance along the sides of the footings. A friction coefficient of 0.50 times the normal dead'load forces is recommended for use in design. Passive resistance may be estimated using an equivalent fluid' weight of 300 pcf. If used in combination with the passive resistance, the frictional resistance should be reduced' by one third to 0.33 times the normal dead load forces. The bearing- soil is non -expansive and falls within the "very low" expansion category in -accordance with 2010 California Building Code (CBC) classification criteria. Slab thickness and reinforcement should be determined by the structural engineer, we "recommend a minimum floor slab thickness of 4.0 inches. All slab reinforcement should be supported on concrete chairs to ensure that reinforcement is placed at slab mid -height. Slabs with moisture sensitive surfaces should be underlain'with a moisture vapor retarder , consisting of a polyvinyl chloride membrane such as 10 -mil Visqueen, or equivalent. All laps within the membrane should be sealed and at least 2 inches of clean sand should be placed over the -membrane to promote uniform curing of the concrete. To reduce the potential for punctures, the membrane should be placed on a pad surface that has been graded smooth without any sharp protrusions: "If a smooth surface can not be achieved by grading, consideration should be given to placing a 1 -inch thick leveling course of sand across the pad surface prior to placement of the membrane. Based on our field observations and understanding of local geologic conditions, the soil profile type judged applicable to this site is So, generally described as stiff soil. The following presents additional coefficients and factors relevant to seismic mitigation for new construction based upon the 2010 California Building Code (CBC):' Sladden Engineering a August 17, 2012 -3- Project No. 544-12079 12-08-207 The seismic design category for a structure may be determined in accordance•with Section 1613 ',of the 2010 CBC or ASCE7. According to the 2010 CBC, Site Class D may be used to estimate •. design seismic loading for the proposed structure.,. The 2010 CBC Seismic Design Parameters are summarized below. f' Occupancy Category,(Table 1604.5): ll-`- L" Site Site Class (Table 1613.5.2): D Y Y. Ss (Figure 1613.5.1): 1.508 ` S1 (Figure 1613.5.1): 0.608 . , Fa (Table 1613.5.3(1)): 1.0 ' Fv (Table 1613.5.3(2)):1.5 ' + Sms (Equation 16-36 {Fa X Ss}): 1.50g � Sm1 (Equation 16-371 Fa.X S1}): 0.908 1 �,. SDS (Equation 16-38 {2/3 X Sms} : 1.00 y { S01 (Equation 16-39 12/3 X Sm1}): 0.60g j . Seismic Design Category: D If you have 'questions regarding this letter or +undersigned. the referenced reports,, please contact the "• `. IL Respectfully submitted, SLADDEN ENGINEERING t y " Brett L. Anderson r Y Principal Engineer No. C4588,q ii Exp• 9-30-2012, . ' Y / m UM' SER • g�' , �9r�, CML ��Q , ry ' - "• . Y • . , .'. . ' � i QFCALIF�� ° . .. f , Copies: 4/Fedderly, & Associates Y r h Y Sladden Engineering a 1