Loading...
13-0637 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: 13-00000637 53552 VIA PISA 772-530-060- - - ADDITION - RESIDENTIAL LOW DENSITY RESIDENTIAL 75000 `i!�4 4 " BUILDING & SAFETY�EPARTMENT Architect or Engineer: BUILDING PERMIT -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Pass: ig - u;cense!u0l./�%1203 Date1/Ci7/ 1 >Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I a exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.l. ( ) I am exempt under Sec. , BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm undef penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued fSec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT Owner: BARNES 53-552 VIA 'LA QUINTA, nwn PISA CA 92253 Contractor: PIERCE CORPORATION, P.O. BOX 3420 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/23/13 ANDREW PALM DESERT, CA 92261-342 (760)346-3228 Lic. No.: 671203 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. yl have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor /_ Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 00041509189 1 certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should bome subject to the worke 'compensation provisions of Section 370 of the Labor Cod I co m o e ovisions. Date:p71; roOt?llicant: WARNING: FAILURE TO SECURE WORKERS' C MPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS (5100,000) IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and c my ordinances and state laws relating to building co tion, and ho 'z epresentatives of this/Ac my toe er upon the above-mentioned property fSW�4 late[' ature (Applicant or Agentl: Application Number . . . . . 13-00000637 Permit . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 527.00 Plan Check Fee 342.55 Issue Date . . . . Valuation . . . . 75000 Expiration Date 1/19/14 Qty Unit Charge Per Extension BASE FEE 414.50 25.00 ----------------------------------------------------------------.,.---------- 4.5000 THOU BLDG 50,001-100,000 112.50 Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . . . 46.74 Plan Check Fee 11.69 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/19/14 Qty Unit Charge Per Extension BASE FEE 15.00 577.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 20.20 577.00 ---------------------------------------------------------------------------- .0200 ELEC GARAGE OR NON-RESIDENTIAL 11.54 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 50.50 Plan Check Fee 12.63 Issue Date . . Valuation . . . . 0 Expiration Date . . 1/19/14 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 2.00 --------------------------------------------------------- 6.5000 EA MECH VENT FAN ------------------ 13.00 Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 54.00 Issue Date . . . . Expiration Date . . 1/19/14 Plan Check Fee . Valuation . . . Qty Unit Charge Per BASE FEE 6.00 6.0000 EA PLB FIXTURE 1.00 3.0000 EA PLB WATER INST/ALT/REP LQPERMIT 13.50 0 Extension 15.00 36.00 3.00 Application Number . . . . . 13-00000637 ---------------------------------------------------------------------------- Special Notes and Comments ADD BATHROOM TO GARAGE 121 SQ. FT. ENCLOSE EXISTING TERRACE AND ADD BATHROOM 456 SQ. FT. 577 SQ. FT. TOTAL . PER 2010 CALIF BUILDING CODE. July 2, 2013 2:08:33 PM JJOHNSON. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 3.00 ENERGY REVIEW FEE 34.26 STRONG MOTION (SMI) - RES 7.50 Fee summary Charged Permit Fee Total 678.24 Plan Check Total 380.37 Other Fee Total 44.76 Grand Total 1103.37 LQPERMIT Paid Credited Due .00 .00 678.24 .00 .00 380.37 .00 .00 44.76 .00 .00 1103.37 RE ca Bin. # , 7ACity of La Quthta MAY 5-2013'. Building 8i Safety Division Permit # P.O. Box 1504,78-495 Calle Tampico Crry La .Quanta, CA 92253 - (760) 777-7o t 90h mijiv, ITY D QUINT Building Permit Application" and Tracking Sheet EVECopM Project Address: V/,0 tOj SA Owner's Name:. S A- P. Number. / 2 – �JO' ©�� -- Address: ��5r VENI9H y�E 5�,�—a�G Legal Description: 4C7-1 7.�/ 5j.>?+AC.7 2 q g y City, Contractor.Axep�-P roep Telephone: ,60 3360 Address: Project Description: City, ST, ZiPPA 1-M —✓F;6 /4 Telephone: �� 1 6 State Lie. #: 6 7/ Z03 City Lic. #; 303 Z CLU E EX�s ' Arch., Engr., Dennnv Designer, C�/ � � � A �� r/� e Address: S" I / /� 107APIX (%Iv 1V �4%% .T j 11 ebafl vj City, ST. Zip: Z,411- Q l)1 tj C'A. ZZS3 LTJ .T / a z� Telephone: 33 Construction Type:./ ocetfpaney: State Lic. #: ` pro c } type Circle one): New Add' ' Alter Repair Demo Name of Contact Person: Sq. Ft.: 5 / - / #Stories: 2 # Units: Telephone # of Contact Person: C%. 301 I Estimated Value of Project: ` Q APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Reed TRACKING PERMrrFEES Pian Sets Plan Cheek submittedoi Item Amount Structural Calci. Reviewed, ready for corrections 3 1Plan Check Deposit. . Truss Calcs. Called Contact Person Plan Check Balance. Title 24 Calci. Plans picked up ���Construction Flood plain plan Plans resubmitted D o /I Grading plan Review, ready for correctios/issue 123 Electrical Subcontattor List Called Contact Person Plumbing Grant Deed Plans picked up S M L H-OAL Approval Plans resubmitted Grading IN HOUSE:- '" Review; ready for correcdo'ns/lssue Developer I arpaet Fee Planning Approval Called Contact Person A.LP.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees o /I Coachella Valley Unified School District 83=733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MI-IGATION AMOUNT: I COMMAND. AMOUNT: DATE: RECEIPT: CFECK#: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: iBarnes_(Residence @.The Hideaway) Date: July 23, 2013 Owner's Name: Phone No. Project Address: 53-552 Via Pisa, La Quinta, CA 92253 Project Description: Room Addition APN: 772-530-060 Tract #: Type of Development: Residential iXX Commercial Total Square Feet of Building Area: 577 sq. ft. Lot #'s: Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: 1!2 Signature: ********************************************************************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. Amount per Sq - Ft -Amount Collected 577 $3.20 $1,846.40 Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Leticia Torres, Facilities Analyst NOTICE OF 90 DAY PERIOD FOR PROTEST OF'EEEKAND STAT%MENXOF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that tb9-09trict provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day aeriod to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts .n the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/mydocs'dcvfccsiceltifkite ofcompliance Ibrm updated 3-2007 11/2010 HIDEAWAY O«ziers Association. April 9, 201.3 Mr. and Mrs. Gerald Barnes 7051 Avenida De Santiago Anaheim Hills, CA 92807 Re: Lot 295 at 53552 Via Pisa Architectural Modification Dear Mr. and Mrs. Barnes: The Hideaway Design Review Committee (DRC) met to review the architectural modifications presented for your home on Via Pisa. The request to enclose the 2' floor covered Terrace was approved as submitted. The massing for the area above 20' will be at 20.2% which is less than the maximum 25% allowed per the guidelines. Please make certain all second floor windows. and doors are recessed a minimum of six inches. This includes the entry doors to the retreat and the shower window.. in the bath. .In addition, all colors and finishes must match the existing structure. Please feel free to contact .Brook Marshall at Brook@dc.rr.com or by phone at 760-219-8057 with any questions regarding this review. Sincerely, The Hideaway Design Review Committee CC: Geralddb@aol.com aol.com studiolineadesign©gmail.com DRC File 80955 AvENUE 52 LA QUINTA, CALIFORMA 92253 • P: 760.393.52.10 F: 760.398.5788 Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 6/17/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Barnes Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Afteration 1611712013 Date Project Address 53-552 Via Pisa La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 577 Addition 577 # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST El Yes 0 No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes O No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavi Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 577 Radiant Barrier New Wall Wood Framed R-21 952 New Floor Wood Framed w/o Crawl Space R-19 121 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Left (N) 22.5 0.390 0.28 none none Bug Screen New Right (S) 50.0 0.390 0.28 6.0 none Bug Screen New Right (S), " 7.5 0.390 0.28 none none Bug Screen New Front (SVtq/ 40.0 0.390 0.28 6.0' none Bug Screen New HVAC SYSTEMS (fit . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump a 00 HSPF Split Heat Pump 13.0 SEER Setback New HVAC DISTRIBUTION Location HeatingCoolin F �-� yr �} I..%� C j ,\I-�- Duct l5uct,Locationr-�„ nco-R-Value Status HVAC cted Ducted Attiq Ceiling-Insfunvent, dl f— --1, 8.0 New Gil; G /� �ic�Tn I(1�1 ATING Type %l Gallons Min. EW z .f � utao _ % - — — JStatus N �P �A OP r M EnefgyPrp 5.1 by EnergySoft User Number. 6712 RunCode: 2013-06-17T10:23:07 ID: Pae 1 of 5 Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 6/17/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Bames Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ® Existing+ Addition/Alteration Date 6/17/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof(R.38.2x 12.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The HVAC System HVAC incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the speed criteria. A uINTA FAFETY DEPT. r•r.. +V -T -P,11 1C.TiON B EnerqyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2013-06-17T10:23:07 ID. Page 2 of 5 Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 6/17/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Barnes Residence 1 ❑ Multi Family to Existing+ Addition/Alteration 1611712013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 5.64 4.75 0.88 Space Cooling 81.24 78.74 2.50 Fans 16.05 17.74 -1.69 Domestic Hot Water 34.69 34.69 0.00 Pumps 0.00 0.00 0.00 Totals 137.61 135.92 1.69 Percent Better Than Standard: 1.2% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (SK) 225 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (SK9 246 40 Fuel Available at Site: Natural Gas (Nw) 320 23 Raised Floor Area: 121 (NE) 186 0 Slab on Grade Area: 0 (SE) 320 58 Average Ceiling Height: 10.0 Roof 577 0 Fenestration Average U -Factor: 0.39 TOTAL: 120 Average SHGC: 0.28 Fenestration/CFA Ratio: 20.8% REMARKS The Hideaway Country Club ^v STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, / 6/17/1013 Address 77-085 Michigan Drive Name Tim Scott Ci /State/ZiPalm Desert Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design re rese ed in this set of construction documents is consistent with the other compliance for mas=and-worksh — wl t so ei ca ions, and with any other calculations submitted with this application, and r6cdg�tizib ao a ce�eM design, permit p duct sealing, verification of refrigerant charge, insulation installation qualltr;,prrtdAuildkgzoiv�lo eia - frog r quire installer testing and certification and field verification by an approved HEASYafer �,OVE AP v Designer or Owner (per Business & Professions Code) FOR ON UCT N Company Studio Linea Design J13 Address 57-770 Black Diamond Name Studio Linea Design 4 '?l1Tc City/State/Zip La Quinta, CA 92253 Phone (760) 899-3368 T:License # Date EnemyPro 5.1 by EnemySoft User Number. 6712 RunCode: 2013-06.17T10:23:07 ID: Pa - e 3 of 5 Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 6/17/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Bames Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Afteration Date 6/17/2013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 577 a026 R-38 0 0 New 4.2.1 A9 2nd Roor Retreat Wall 298 0.069 R-21 0 90 New 4.3.1 A6 2nd Floor Retreat Wall 1861 0.069 R-21 90 90 1 New 4.3.1-A6 2nd Floor Retreat Wall 263 0.069 R-21 180 90 New 4.3.1-A6 2nd Floor Retreat Wall 20 0.069 R-21 225 90 New 4.3.1-A6 2nd Floor Retreat Wall 186 0.069 R-21 270 90 New 4.3.1 A6 2nd Roor Retreat Floor 121 0.048 R-19 0 180 New 4.4.2-A4 2nd Floor Retreat FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 7.5 0.3901 NFRC 0.28 NFRC 0 New Dual Non Metal 2nd Floor Retreat 2 Window 7.5 0.390 NFRC 0.28 NFRC 0 New Dual Non Metal 2nd Floor Retreat 3 Window 7.5 0.390 NFRC 0.28 NFRC 0 New Dual Non Metal 2nd Floor Retreat 4 Window 25.0 0.390 NFRC 0.28 NFRC 180 New Dual Non Metal 2nd Floor Retreat 5 Window 25.0 0.390 NFRC 0.28 NFRC _ 180 New Dual Non Metal 2nd Floor Retreat 6 Window` .N f7.5 0.390 NFRC r X0.28 NFRC -180 New Dual Non Metal - ?_f J,,'- -', 2nd Floor Retreat 7 Window *40.0 0.390 NFRC 0.28 'NFRC 225 New Dual Non Metal 2nd Floor Retreat - - - (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade T H e SHGC t Wd Ove ang Left Fn Len Hat LExt RExt Dist Len Ri ht in H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5.0 5.0 6.0 0.1 6.0 6.0 5 Bug Screen 0.76 5.0 5.0 6.01 0.1 6.01 6.0 6 Bug Screen a76 rIL 7 Bug Screen 0.76 8.0 5.0 6.0 0.1 6.0' �_A r- �. At. hi`.! V L- _ F1 0 II f Al v�TE _ -r---- EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2013-06-17710:23:07 ID: Page 4 of 5 Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 6/17/2013 ,CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5) CF -1 R Project Name Barnes Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Afteration IDate 6/17/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered I Removed Volume Year Built HVAC 2nd Floor Reheat 577 5,770 Totals 577 0 0 0 HVAC SYSTEMS System Name Ot . Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 Split Heat Pump 8.00 HSPF Split Heat Pump 13.0 SEER Setback New !x 1 `-- HVAC DISTRIBUTION d t ] 4 4 System Name Heating ,..'Duct L� Ducts"':; Coolinq Duct Location -Value Tested? Status HVAC Ducted —R Ducted Attic, Ceiling Ins, unvented 8.0 m New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status existing dhw 1 Small Gas All Pipes Ins 40,000 50 0.61 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATI�I Control Hot Water Piping Length v a — DFt f3UILD.!`!G & SAFE` {73Pipb� S stern Name DEPT. i e Insul. eter Thick. HP Plenum Outside Buried o - ❑ ,-TF-jig EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2013-06-17710:23:07 ID: -Pa---e 5 of 5 • i BUILDING ENERGY ANALYSIS REPORT . PROJECT: Barnes Residence 53-552 Via Pisa La Quinta, CA 92253 Project Designer: Studio Linea Design 57-770 Black Diamond La Quinta, CA 92253 (760) 899-3368 Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 Job Number: Date: 5/1/2013 The EnergyPro computer program has been used to perform the calculations summarized in this authorized by the California Energy Commission for use with both the Residential and Nonresi This program developed by EnergySoft, LLC — www.ene RECEIVED MAY 15 2013 CoMMC y O LA QUINZA DEVELOPMENT TY OFQv�DEPA G� SAFEN gU1LD►►�PFtOVEpN F r-ORCONS-` UC110 EnergyPro 5.1 by EnergySoft User Number.' 6712 RunCode: 2013-05-01T13:01:24 ID: C r 1 LJ • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Barnes Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Iteration Date 5/1/2013 Project Address 53-552 Via Pisa La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond.' Floor Area 577 Addition 577 # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST El Yes 0 No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes O No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 577 Radiant Barrier New Wall Wood Framed R-21 952 New Floor Wood Framed w/o Crawl Space R-19 121 New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Left (N) 22.5 0.390 0.28 none none Bug Screen New Right (S) 50.0 0.390 0.28 6.0 none Bug Screen New Right (S) 7.5 0.390 0.28 none none Bug Screen New Front (SVV) 40.0 0.390 0.28 6.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff The•mostat Status 1 Split Heat Pump 8.00 HSPF Split Heat Pump 13.0 SEER SetbacF New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC Ducted Ducted Attic, Ceiling Ins, unvented 3.0 New WATER HEATINGQ��NTA Ot . Type Gallons Min. Eff tst 1 u&� LA Status ING & S o RU EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05- T13:01:24 1 Page 3 of 14 Y • C7 9 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Barnes Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ® Existing+ AdditiorrlAlteration Date 5/1/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof(R.38.2x 12.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installaton criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The HVAC System HVAC incorporates HERS Verified Refrigerant Change ora Charge Indicator Display. The HVAC System HVAC incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is raquired to verify that duct leakage meets the specified criteria. BUILDING & SAFETY DEPT. APPROVED FOR CONS I rt, I IDA.TE B Ene Pro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-05-01713:01:24 '--1 a e 4 of 14 • • • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Barnes Residence 1 ❑ Multi Family m Existing+ Addition/Alteration 5/1/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 5.64 4.75 0.88 Space Cooling 81.25 78.82 2.43 Fans 16.05 17.75 -1.71 Domestic Hot Water 34.69 34.69 0.00 Pumps 0.00 0.00 0.00 Totals 137.63 136.02 1.61 Percent Better Than Standard: 1.2% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (SM 225 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S K9 246 40 Fuel Available at Site: Natural Gas (NV19 320 23 Raised Floor Area: 121 (NE) 186 0 Slab on Grade Area: 0 (SE) 320 58 Average Ceiling Height: 10.0 Roof 577 0 Fenestration Average U -Factor: 0.39 TOTAL: 120 Average SHGC: 0.28 Fenestration/CFA Ratio: 20.8 REMARKS The Hideaway Country Club STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 1 13 Address 77-085 Michigan Drive Name Jon Scott City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone (760) 200-4780 Si ned Date The individual with overall design responsibility hereby certifies that t osed buildin desk n represented in this set of construction documents is consistent with the other compliance for s �1 �g s w h s I on ,and F�ietf�f�or A, �i � ign, with any other calculations submitted with this permit application, and ec duct sealing, verification of refrigerant charge, insulation installation q al ba rd e® EiWqu e installer testing and certification and field verification by an approved ERS r�0 D Designer or Owner (per Business & Professions Code) FOR Ip Company Studio Linea Design , 1� /> / Address 57-770 Black Diamond Name Studio Linea Desi nDATE City/State/Zip La Quinta, CA 92253 Phone (760) 899-3368 Date Enenqyap 5.1 bV Ene Soft User Number: 6712 RunCode: 2013-05-01713:01:24 0: Page 5 of 14 • • CERTIFICATE OF COMPLIANCE: Residential (Part 4 :)f 5 CF -1 R Project Name Barnes Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Additicn/Alteration Date 5/1/2013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix ape Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 LocatioNComments Roof 577 0.026 R-38 0 0 New 4.2.1-A9 2nd Floor Retreat Wall 298 0.069 R-21 0 90 New 4.3.1-A6 2nd Floor Retreat Wall 186 0.069 R-21 90 90 New 4.3.1-A6 2nd Floor Retreat Wall 263 0.069 R-21 180 90 1 New 4.3.1-A6 2nd Floor Retreat Wall 20 0.069 R-21 225 90 1 New 4.3.1-A6 2nd Floor Retreat Wall 186 0.069 R-21 270 90 1 New 4.3.1-A6 26d Floor Retreat Floor 121 0.048 R-19 0 180 New 4.4.2-A4 2nd Floor Retreat FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 7.5 0.390 NFRC 0.28 NFRC 0 New Dual Non Metal 2nd Floor Retreat 2 Window 7.5 0.390 NFRC 0.28 NFRC 0 New Dual Non Metal 2nd Floor Retreat 3 Window 7.5 6.390 NFRC 0.28 NFRC 0 New Dual Non Metal 2nd Floor Retreat 4 Window 25.0 0.390 NFRC 0.28 NFRC 180 New Dual Non Metal 2nd Floor Retreat 5 Window 25.0 0.390 NFRC 6.28 NFRC 180 New Dual Non Metal 2nd Floor Retreat 6 Window 7.5 0.390 NFRC 0.28 NFRC 180 New Dual Non Metal 2nd Floor Retreat 7 Window 40.0 0.390 NFRC 0.28 NFRC 225 New Dual Non Metal 2nd Floor Retreat (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC Hot Wd Ove hanq Left Fin Len Hot LExt RExt Dist Len Ri ht Fin Hot Dist I Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5.0 5.0 6.0 0.1 6.0 6.0 5 Bug Screen 6.76 5.0 5.0 6.0 0.1 6.0 6.0 6 Bug Screen 0.76 7 Bug Screen 0.76 8.0 5.0 6.0 0.1 6.0 6.0 1 � o Ely... { f'i 1 DATE EnergyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2013-05-01T13:01:24 4--11Pa e 6 of 14 • I� • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Barnes Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family 0 Existing+Additicn/Alteration Date 5/1/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existi nq Altered Removec Volume Year Built HVAC 2nd Floor Retreat 577 5,770 Totals 5771 0001 0 HVAC SYSTEMS System Name O Heatin Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 Split Heat Pump 8.00 HSPF Split Heat Pump 13.0 SEER Setbacr New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R-Val■e Ducts Tested? Status HVAC Ducted Ducted Attic, Ceiling Ins, unvented 8.0 0 New El WATER HEATING SYSTEMS S stem Name T e Distribution Rated Input Btuh Tank Cap. al EnergylStandbylTank Factorsul. or REValue Ext. R- Status existing dhw 1 Small Gas All Pipes Ins 40,000 50 0.61 n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ftc — �.------ -�-�/ CIV t �� �ir��P SF,,)Name,lNa&en th QUINT Ins I. i e er ihi,k. D . HP Plenum Outside Buried ❑ 1 FOR '4 ❑ M i DA EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-01713:01:24 L ---ID. Page 7 of 14 L C 0 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Date Barnes Residence 1 5/1/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Sumnary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum compo -lent performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. 6116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, --ertified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include cn CF -6R Form. ;-§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. '*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150 (c): Minimum R-13 insulation in wood -frame wall orequivalent LI -factor. *9150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3°x; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire open hof the firebox. -§150(e)113: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is --equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indbor air is vented to the -outside of the building, are prohibited. :Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are ,,ertified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of113 cam. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA. §150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1506)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1506)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water "tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the _tank. "§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of -recirculatina sections of hot water pipes are insulated per Standards Table 150-13. §1506)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heatinc-seers rjdir ct hot water tank shall be insulated to Table 150-B and Equation 150-A. §1506)2: Pipe insulation for steam hydronic heating systems or hot water systems 5 psi meets the -.regi rea to -Panda ds Table .123-A. _ ,. 9- .150 §1 50' 3A: Insulation is protected from damage, including that due to sunlight, moisu vette ui pment�mai dance- an wind. §1506)3A: Insulation for chilled water piping and refrigerant suction lines includes a vaporr retar"daritto Iii -e d�t §e 1`Vy in conditioned space. .'�i §1500)4: Solar water -heating systems and/or collectors are certified by the Solar'Ratin and C rti ication C oration. B DATE EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-05-01T13:6-27=- /D: Page 8 of 14 C MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Barnes Residence 1 5/1/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requi-ements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a mi.iimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closu-e system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of !JL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities andlsupport platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubboer adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. 5150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with tf•e Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with derating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and haater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. §150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire orexhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a ;ine-voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §1' 0(d), and shall not contain a medium screw -base socket. §150(k)6: Lighting integral to exhaust fans in rooms other than kitchens shall meet the applicable requirements of §1-50(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and aIL1gguqanentIy installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility_r-ooms �c trolled by a manual -on occupant sensor. , r r- §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 2 w� 3r"jljpe r foot of illuminated cabinet. :'� & S r-,;QR T CTION EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2013-05-01713:01:24 — f : Page 9 of 14 • • MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Barnes Residence 1 5/1/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficac; luminaires shall be -allowed provided they are controlled by either a dimmer switch that complies with the applicable requiremens of §119, or by a manual - .on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in deta•;hed storage building less than 1000 square feet located on a residential site is not required to comply with 1 50 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential beildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; CR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. '§1 50(k)l 4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no :more than five watts of power as determined according to &130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires Shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of §1 '9. CITY OF LA QUINTA BUILDING & SAFEW DEPT. APPROVED FOR CON RUCTION DATE I B EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2013-05-01713:01:24 ID: Page 10 of14 r� HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Barnes Residence System Name HVAC ENGINEERING CHECKS SYSTEM LOAD Number of Svstems 1 Cooling! Outpi Total Total Total Air System CFM per S Airflow cin Airflow (cfn Airflow (cfn Outside Air Outside Air Note: values ab4 HEATING SYS 26 OF Outside Air 0 cfm 68 OF 112/78°F Outside Air 0 cfn, 75168 °F EnergyPro 5.1 18,000 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 18,000 31.2 18,000 18,000 1.5 31.2 384.7 800 HVAC EQUIPMENT SELECTION 800 6RHBC3RH First company 1.39 533.3 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 0.00 ARI conditions HROMETRICS (Airstream Temperatures at Time Date 5/1/2013 Floor Area 577 COIL COOLING PEAK_ COIL HTG. PEAK CFM Sensible Latent CFM Sensible 639 6,461 681 547 7,384 0 304 224 0 0 0 0 0 0 0 0 0 304 224 7.0701 681 i 7,831 8,7031 8,1391 i 11,2421 8,7031 8,139 1 11,242 Aug 3 PM Jan 1 AM 68 OF 81 OF 81 OF _♦ f (�) aJ Heating Coil Supply Fan 81 OF 800 cfm ROOM 68 OF OMETICS (Airstream Temperatures at Time of Cooling Peak) 75/68°F 65/65°F 65/65°F N Supply Fan �Ty OFCooling Coil800 cfm BUDING & �.PP i FOR CON i 7 o.ATE AA User Number: 6712 RunCode: 2013-05-01713:01:24 /D: UINTA � DEPT. 5165 OF QOM C 7 / 68 °F 11 of 14 • 0 '•• •�� �' Project Barnes .- •- System Name HVAC .. 577 ROOM LOAD SUMMARY .. ..... . PAGE TOTAL TOTAL • 0 • ROOM HEATING PEAK LOADS Project Name Date Barnes Residence 5/1/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Retreat Time of Peak Jan 1 AM Floor Area 577.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 68 OF Conduction Area U -Value AT OF Btu/hr R-38 Roof(R. 38.2x 12.16) 577.0 X 0.0260 X 42 = 630 R-21 Wall (W.21.2x6.16) 952.0 X 0.0690 X 42 = 2,759 Dual Non Metal 120.0 X 0.3900 X 42 = 1,966 R-19 Floor No Crawlspace 121.0 X 0.0480 X 42 = 244 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X - -X-- U— Items shown with an asterisk (') denote conduction through an interior surface to another room �� ! age �0 aNTA 5,599 •_;'s.;...;;�,.G & SAFETY DEPT. Infiltration:[ 1.00 X 1.064 X 577 X 10.00 X 04,15 0 4 = 1,786 Schedule Air Sensible Area Ceiling Height ION Fraction ! I u � CONS TOTAL HOURLY HEAT LOSS FOR ROOM 7 384 Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2013-05-01713:01:24 ID: Page 13 of 14 • r RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Barnes Residence 5/1/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Retreat Outdoor Dry Bulb Temperature 112 OF Floor Area 577.0 RZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x 12.16) (N) 577.0 X 0.0260 X 56.0 = 840 R-21Wall (W.21.2x6.16) (N) 297.5 X 0.0690 X 23.0 = 472 R-21 Wall (W.21.2x6.16) (E) 186.0 X 0.0690 X 33.0 = 424 R-21 Wall (W.21.2x6.16) (S) 262.5 X 0.0690 X 26.0 = 471 R-21Wall (W.21.2x6.16) (SIAL 20.01 X 0.0690 X 31.0 = 43 R -21W611 (W.21.2x6.16) (W) 186.0 X 0.0690 X 33.0 = 424 R-19 Floor No Crawlspace 121.0 X 0.0480 X 19.0 = 110 X X = X I X = Page Total 2,783 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (N) 0.0 X 18.2 + 7.5 X 18.2 = 136 Window (N) 0.0 X 18.2 + 7.5 X 18.2 = 136 Window (N) 0.0 X 18.2 + 7.5 X 18.2 = 136 Window (S) 25.0 X 18.2 + 0.0 X 18.3 = 455 Window (S) 25.0 X 18.2 + 0.0 X 18.3 = 455 Window (S) 0.0 X 18.2 + 7.5 )t 18.3 = 137 Window (SM 40.0 X 18.2 + 0.0 X 24.6 = 728 X + N _ X + X = Page Total 2,183 Internal Gain Btu/hr- tu/hrOccu ants Occupants 0.0 Occupants X 230 Btuh/occ. = 0 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.20 X 31.57 X 37 = 1,494 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM ,, �-�,+ (1 6,461 "C r DEPT. i�IJILC?iNG & SAFETY Latent Gain Occupants 0.0 Occupants X a 2001 Y uCyp c. V ED Btu hr 0 CON UCTIO Infiltration: 4,771 FOR X 1.20 X 31.57 X 0.00376 �= 681 Air Sensible CFM ELA AW i DATE TOTAL HOURLY LATENT HEAT GAIN FOR ROOM I 681 EnemvPro 5.1 by EnemySoft User Number. 6712 RunCode: 2013-05-01713:01:24 ID: Pae 14 of 14