Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
06-1538 (SFD)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description Property Zoning: Application valuation: Applicant: 06-00001538 53713 VIA PISA 772-530-050- - - DWELLING - SINGLE FAMILY LOW DENSITY RESIDENTIAL 430380 • �'S�VIilJ� ' VOICE (760) 777-7012 BUILDING & SAFETY DEPARTMENT ff5FSPECAL NS (110) 77 3 BUILDING PERMIT U Owner: Dtc C) y, g00612 PETER CHAPMAN 227 2 0TH ST #100 CnY OF LA QUINTA DETACHED PALM SPRINGS, CA 92263 mmagaFT-z _- Architect or Engineer: Lic. No.:--------------- -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.' License Class: B License No.: 565847 Date: Contrac OWNER -BUILDER DECLARATION I hereby affirm under pen ty of perjury at I am exempt from the Contractor's State License Law for the following reason (Sec. 703 ss and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of notmore than five hundred dollars (S500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractorls) licensed pursuant to the Contractors' State License Law.). (_ I I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERDIIT Contractor: JC LINK GENERAL CONTRCTING INC 45120 SAN PABLO, STE #2-I PALM DESERT, CA 92260 (760)568-6070 Lic. No.: 565847 ------------------ WORKER'S COMPENSATION DECLARATION Thereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0034681 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, 1 shall forthwith comply with those provisions. Date: a� App' ' WARNING: FAILURE O SECURE WO KERS' COMPENSATION COVE�GElNLAWFUL, AND SHALL SUBJECT AN EMPLO TO CRIMI L PENALTIES AND CIVIL FINESE HUED THOUSAND DOLLARS IS 100,0001 I N TO THE COST OF COMPENSATAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . _ Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. certify that I have read this application and state that the above information is correct. Iagree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of thiscountyto enter upon the above-mentioned property for inspection purposes./ Date:[ '2I Signature (Applicant or Age ✓ I �p Application Number Permit . . . Additional desc . . Permit Fee . . . . Issue Date . . . . Expiration Date . . . . 06-00001538 BUILDING PERMIT 1798.00 5/20/07 Plan Check Fee . . 1168.70 Valuation . . . . 430380 Qty Unit Charge 'Per Extension BASE FEE 639.50 331.00 3.5000 THOU BLDG 100,001-500,000 1158.50 ---------------------------------------------------------------------------- Permit . . . ELEC-NEW RESIDENTIAL Additional desc . . Permit Fee . . . . 217.16 Plan Check Fee 54.29 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/20/07 Qty Unit Charge Per Extension BASE FEE 15.00 4933.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 172.66 725.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 14.50 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit. . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check.Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/20/07 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit MECHANICAL Additional desc . Permit Fee . . . . 157.00 Plan Check Fee 39.25 _J Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/20/07 Qty Unit Charge Per Extension BASE FEE 15.00 5.00 9.0000 EA MECH FURNACE <=100K 45.00 5.00 9.0000 EA MECH B/C <=3HP/100K BTU 45.00 7.00 6.5000 EA MECH VENT FAN 45.50 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 LQPERI%IIT (! fe Application Number . . . . . 06-00001538 Permit PLUMBING Additional desc . . Permit Fee . . . . 210.00 Plan Check Fee 52.50 Issue Date . . . .Valuation . . . . 0 Expiration Date . . 5/20/07 Qty Unit Charge Per Extension BASE FEE 15.00 21.00 6.0000 EA PLB FIXTURE 126.00 1.00 25.0000 EA PLB BUILDING SEw.Ex '15.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM' 9.00 16.00 .7500 EA PLB GAS PIPE >=5 12.00 1.00 15.0000 EA PLB GAS METER 15.00 --------------------------------- ------------------------------------------ Special Notes and Comments 4933 sq. ft. sfd.this permit does not include pool & spa block walls or driveway approach.November 21, 2006 10:59:45 AM jjohnson ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 575.95 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 480.00 ENERGY REVIEW FEE 116.87 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE 15.00- 5.00DIF DIFLIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 43.03 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES '1666.00 Fee summary Charged Paid Credited ---------------------------------------- Due ----------------- Permit Fee Total 2397.16 .00 .00 2397.16 Plan Check Total 1314.74 500.00 .00 814.74• Other Fee Total 4446.85 .00 .00 4446.85 Grand Total 8158.75 500.00 .00 7658.75 LQPERMIT Building Address P.O. BOX 1504 \ l 78-495 CALLE TAMPICO `7 3 Vii 1 54 LA QUINTA, CALIFORNIA 92253 mailing Address OZ7 Z����� A—INAW—A Zip Tel Contractor ` E J Address City ip Te State Lic. & Classif. City Lic. # Arc gr., ,. gner Ad5ress /n _ .T' fel. Lic #� �C0,0 L LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). 01, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) O 1 am exempt under Sec. B. & P.C. for this reason Date -Ow r WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.' If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE C^O7NST_ A.P. Number ::z/ Legal Description Project Description E59. Ft. �'J`�' � No. Size 'Z7K SID New Add ❑ ILstlmated valuation O APPLICATION ONLY OCC. CRFf / No. DIN. Units Alter ❑ Repair ❑ Demolition ❑ PERMIT AMOUNT Plan Chk. Dep. S601 Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by:— Validation: YELLOW = APPLICANT PINK = FIN%NCE Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AP.P.R:: T: i DATE: RECEIPT: CHECK k: rN1TIALS: I CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Residence is'atthe Hideaway Date: November 20, 2006 Owner's Name: Peter Chapman Phone No. 275-6710 Project Address: 53-713 ViwPisa La Quinta, C_Aa Project Description: 1 SFD APN: 772-530-050 Tract #: I.ot #'s: Type of Development: ResidentialCommercial Total Square Feet of Building Area: 4,933 sq. ft. Industrial Certification of Applicant/Owners: The person sigaing certifies that the above information is correct and makes this statement ander penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/devcioper. Dated: November 20,2006. Signature: JOVE SCHOOLDISTRIC'T'SREQLTIRE.MENTSFOR PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING. (CIRCLE ONE) Education Code Gov. Code Project 17620 65995 Approval I Number of Sq.Ft. 4,933 ,kmount per Sq.Ft. $3.75 Amount Collected $18,498.75 Building Permit Application Completed: Xes/No By: Carey M. Carlson, Asst. Supt., Business Serves F14 Agreemerst Existing Prior to 1/1/87 Certificate issued by: Elvira Mattson, Office Technician Signature: Not Subject to Flee Requirement NOTICE OF 90 DAY PERIOD �OR+ROTtST OF FEES ANL S'l'ATEME.NT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this Listrict provide (1) a viritten notice to the project appellant, at the time of payment of school fees, mitigation payment or ot!ler exactions ("Fees"), of the 90 -da} period to protest the imposition ol'the e Fees aad (2) the amount of the fees. Therefore, in accordance with section 66C23 of the Government code and other- applicable law, this Notice shall serve ul advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences wi:lr thr paymeu: of the fees or perforntaace of any other requirements as described in section 66020 of the Government cod.. Additionally, the amount of the fec� irnp-.scd is a:. hercir set forth, whether tial able at this time or in whole or in part prior to issuance of a Certii°-_ate ci Occupancy. As in the latter, the 90 days starts •or..'Oe dais, here .af. This Certificate of Compliance is valid for thirty (30) day.} from the date of issaancs. ! xtension will be -:•ahted only for good cause, as determined by the School Dislric,, and . d to three (3) such extensions may be groal;ed. At such,time as th`. Certificate expires, if a build!ng permit has not beet issued for the project that is il., :. of this Certificate, the owner will 54 r,ip�ursO all fees that were paid to obtain this Certificate of Compliarsee. �1'ti':c ra�Jocskir_,.Pees/c rutictne o.f :.c:a 1/16/03 T lance tbrm tablesTo liSE-doc DO rn S r6 GC rfo_N WHEN RECORDED MAIL TO: Chapman Family Trust 227 20"' Str., Ste. 100 Newport Beach, CA 92663 MAIL TAX STATEMENT TO: SAME AS ABOVE T /_7 D.2 -e DOC = 2003-958717 12/08/2003 08:00A Fee:10.00 Page 1 of 2 Recorded in official iRecords County Of Gary L. Orso Assessor, County Clerk 8 Recorder II11� jjqI IIII IIIIIII It til���t III lit It 11 M S U PAGE SIZE DA PCOR NOCOR SMF MISC. � a A R L COPY LONG 11 REFUND NCNG E%AM DOCUMENT TRANSFER TAX $ 11 Computed on the consideration or value of property conveyed; OR Computed on the consideration or value less liens or encumbrances remaining at the time of sale. Signature of Declarant or Agent determining tax — Firm Name GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Peter Chapman and Molly Chapman, husband and wife, ("Grantor"), hereby GRANT(S) to Peter Chapman and Molly Chapman, Trustees of the Chapman Family Trust dated 5/28/03 ("Grantee"), the real property located in the City of La Quinta, County of Riverside, State of California, described as: . Lot 285 (the "Lot") of Amended Tract No. 29894-2 as, shown on Subdivision Map (the "Map") recorded on December 12, 2002, in Book 327, Pages 56 to 88, inclusive, of Maps, in the Office of the Riverside County Recorder. SUBJECT TO all matters of record, without limitation, all other covenants, conditions, restrictions, reservations, easements, rights and rights-of-way of record including, without limitation, the Declaration and the Map for Tract No. 29894=2. Dated I &-d .....� CJ Peter Chapman I E Molly Cha an FIDELITY NATIONAL TITLE INSURANCE COMPANY HAS RECORDED THIS INSTRUMENT BY REQUEST AS ANACCOMMODIATION ONLY AND HAS NOT EXAMINED ITFOR REGULARITY AND SUFFICIENCY ORAS -TO ITS EFFECT UPON THE TITLE TO ANY REAL PROPERTY THAT MAY BE DESCRIBED THEREIN '1` i CALIFORNIA ALL-PURPOSE ACKNOWLEDGMENT State of California ss. County of C�rb.r.os�t_ On C>c*bloelr aQ ;lM:>3 before me, 4Y% as Qe34sr.��t Date I Name and Title of Officer (e.g., "Jane Doe, t otary Public) personally appeared";aL*_c CNNMR:!! .^ Name(s) of Signer(s) 96ersonally known to me ❑ proved to me on the basis of satisfactory AMBER -LEE MC LEAN evidence Commission # 1337243 Z Z Notary Public - California > Orange County My Comm. Expires Jan 30, 2006 to be the person(s) whose name(s) -is/are subscribed to the within instrument and acknowledged to me that hefiahe/they executed the same in A49;'herltheir authorized capacity(ies), and that by h+qAieetheir signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted,,.executed the instrument. WITNESS my hand and official seal. u Qti- Signature of RlMiryftblic OPTIONAL Though the information below is not required by law, it may prove valuable to persons relying on the document and could prevent fraudulent removal and reattachment of this form to another document. Description of Attached Document Title or Type of Document: 2Q" Document Date: Signer(s) Other Than Named Above: Capacity(ies) Claimed by Signer Signer's Name: ❑ Individual ❑ Corporate Officer — Title(s): _ ❑ Partner — ❑ Limited ❑ General ❑ Attorney -in -Fact ❑ Trustee ❑ Guardian or Conservator ❑ Other: Signer Is Representing: Number of Pages: RIGHT THUMBPRINT OF SIGNER Top. 0 1999 National Notary Association - 9350 De Soto Ave., P.O. Box 2402 - Chatsworth, CA 91313-2402 - www.nationalnotary.org Prod. No. 5907 Reorder: Call Toll -Free 1-800-876-6827 HIDEAWAY OWNERS ASSOCIATION July 21, 2005 David Pierce Hohmann 555 Anton Blvd. Costa Mesa, CA 92626 RF,: Chapman/Final Worldng Drawings - Revisions Lot 285 at 53713 Via Pisa Dear Mr. Hohmann: The Hideaway Design Review Committee met to discuss the revisions to the Final Working Drawings for Lot__, _285. The DRC is providing you with a `Conditional' approval of the Final Working Drawings so your plans; may be submitted to the City of La Quinta for plan check.' The DRC will also accommodate the scheduling of a Pre -Construction meeting at the lot however, construction may NOT commence until the comments listed below are resolved and Final plans are given complete DRC approval. 2.11 Walls, Fences and Gates a. There were no details or elevations provided for the walls or gates at the exmior courtyard that was added.. Please clarify the intent/design, 2.13 Planting . a. The Xylosma hedge cannot be eliminated from the planting plan. In additmn, a 14' cut in the HOA easement planting for the purposes of a driveway is acceptable as well as a minimal break in the planting for a pedestrian walkway. b. The following plants are not allowed for use in the front and rear Transition Areas: Caesalpinia pulcherrima, Leucophyllum., Heteromeles, Dietes. C. The rear yard planting is not Transitional to he Natural Area (arrangemen_ of shrubs forms a line/edge/border). d. There are property line walls extending into the view corridor on both sides of the lot. Walls must step down to 3' in the Transition Areas and should not extend all the way to the rear property line. e. Courtesy comment: The main trees proposed are fast growing and will get large which are positive attributes however, they are deciduous and will be bare all winter/iigh season. Please discuss this with your client. The committee would prefer to see an alternative trees) utilized in this highly visible area. f. The committee does not recall receiving a lighting plan for review. 3.4 Building Forms and Massing a. The committee is somewhat concerned about the proposed deck as this is a. single- story home. Please clarify the expelled usage of this dock. Additionally, the committee; would prefer to see the deck/loggia pulled back at the right side so that it stops prior to covering the fireplace. Please call Brook Marshall at (760) 346-1161 with any questions or concerns. Sincerely, Hideaway Design Review Committee CC: DRC File DESERT RESORT MANAGEMENT POST OFFICE BOX 4772 / PALM DESERT, CALIFORNIA 92261-4772 73-350 ALESSANDRO, SUITE 5 / PALM DESERT, CALIFORNIA 9226o PHONE 76o.346.I161 / FAX 76o.346.991S / E-MAIL: ASSOCIATION@HIDEAWAYGOI.FCLUB.COM 05/23/2007 06:52 7605684439 J.C.LINK INC. PAGE 02 lylay 41 WI U I.Uup ova cog ino 1W540858 p2 SVA ENGINEERING, INC. 14471 Chamkia RoA Suite 103 Tustin, Mfvrnia 92780-7210 U.S.A. Phorc; (949) 654-OSS6 Fax; (949) 6S4-0658 (714) 734-9734 (714) 34+6577 0 May 21, 2007 NOTE TO 1NSPECTOlUCO.NMkCTOR ,1E: CHAPMAN residence PROJECT ADDRESS: 73s1A 6a Pisa. La 11inta, Cs 92253 To WbQM it May Concern; Pursuant to my structural observation of the above referenced property, on Mav 19, 2007, please take a ooze of the toll -owing: The following items need to be corrected: 1) 15'-6" shear wall at the garage has been reduced to 8'-0" wail, liIICleiL4e nailing pattem to shear wall type 3 and add M5A at the end of the shear wall with.Simpson set epoxy and 12" embedment into concrete; 2) At the dincting room, anchor boll for HU 1 DA is missing, Provide appropriate anchor bolt for HD10A with Simpson epoxy, IS" embedded into concrete, with special inspection, 3) One machine boh is missing at post to holdown at master bathroom, Should you have any questions, please do not hesitate to contact the i x1ersigned at (949) 654-OB56 at your convenience. Sincerely yours, SIAMAX VABDAT War Certificate of Occupancyof� 2_ INcwroanTsn� 5 OF Building & Safety Department' This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 53-713 VIA PISA Use classification: SINGLE FAMILY DWELLING Building Permit No.: 06-1538 Occupancy Group: R-3 Type of Construction: VN Land Use Zone: RL Owner of Building: PETER CHAPMAN Address: 227 20th ST #100 City, ST, ZIP: PALM SPRINGS, CA 92263 By: STEVE TRAXEL fit Date: December 6, 2007 Building Official POST IN A CONSPICUOUS PLACE I TITLE 24 REPORT I CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPR V"ED Title 24 Report for:FOR CONST LCTION Chapman Resid B 53-713 Via Pisa, The a La Quinta, CA 92253 Project Designer: David Pierce Hohmann, Architect 555 Anton Blvd., Suite 850 Costa Mesa, CA 92626 (714) 241-3600 Report Prepared By: Tim Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 Job Number: Date: 11/21/2006 D computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.2 by EnergySoft Job Number: User Number: 6712 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 8 10 11 14 17 21 EnergyPro 4.2 by EnergySoft Job Number: User Number: 6712 Certificate Of Compliance : Residential (Part 1 of 4) CF -1R better than Standard: Building Type: Y Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (E) 90 deg Natural Gas Area: 734 ft2 Avg. U: 0.64 Ratio: 14.9% Avg. SHGC: 0.49 ILDING ZONE INFORMATION one Name Floor Area Volume OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Roof Wnnd R65 0094 R-1$ -7 n 145 n Wall Wood 517 0069 R_21 R-0 0 345 gQ Wall Wood 160 0 069 R-21 R-0 0 75 90 Wall Wnnd 1R0 0069 _R-91—$,QQ X65 so Wall Wood 240 0 069 R-71 R-0.0 755 90. Roof Wood 525 0024 R_38 R-7 0 345 �. Wall Wnnd 227 n n6g R-71 R-0 0 '445 AQ Wall Wnnd 17R n n69 R_91 R -n n 7gAn Wall Wood 758 0069 R21 R -n n 165 An Roof Wood 2,879 0.024 R_38 R-7 0 345 Q Wall Wnnd 360 n n6g R_91 R -n n 145 g0 Wall Wnnd 324 n n6A 13_71 R -n n 75 g0 Wall Wood 164 0 069 R-21 R-0 0 165 An Wall Wood 587 0.069 R_21 R-0.0 255 gQ Roof Wnnd 664 _n n24 R_38 R-7 0 n n Wall Wnnd 187 0 069 R_21 R-0 0 7.5,9.Q Wall Wnnd 3R5 n 069 R-71 R -n n 165 A0 Total Conditioned Floor Area: 4,933 ft2 Existing Floor Area: 11/21/2006 Date oject Title 0 ft2 Slab on Grade Area: Project Address ft2 Average Ceiling Height: 12.5 Building Permit # Scott nPsinn & Title 94 1.00 (760) 200-4780 1 Documentation Author Telephone plan Check/Date FnPrgVPro 15 1 Field Check/Date Compliaar ce Method Climate Zone TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 1.58 2.11 -0.53 Space Cooling 51.33 43.27 8.06 Fans 7.72 7.88 -0.17 Domestic Hot Water 5.20 8.35 -3.15 Pumps 0.00 0.11 -0.11 Totals 65.82 61.72 4.10 better than Standard: Building Type: Y Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (E) 90 deg Natural Gas Area: 734 ft2 Avg. U: 0.64 Ratio: 14.9% Avg. SHGC: 0.49 ILDING ZONE INFORMATION one Name Floor Area Volume OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Roof Wnnd R65 0094 R-1$ -7 n 145 n Wall Wood 517 0069 R_21 R-0 0 345 gQ Wall Wood 160 0 069 R-21 R-0 0 75 90 Wall Wnnd 1R0 0069 _R-91—$,QQ X65 so Wall Wood 240 0 069 R-71 R-0.0 755 90. Roof Wood 525 0024 R_38 R-7 0 345 �. Wall Wnnd 227 n n6g R-71 R-0 0 '445 AQ Wall Wnnd 17R n n69 R_91 R -n n 7gAn Wall Wood 758 0069 R21 R -n n 165 An Roof Wood 2,879 0.024 R_38 R-7 0 345 Q Wall Wnnd 360 n n6g R_91 R -n n 145 g0 Wall Wnnd 324 n n6A 13_71 R -n n 75 g0 Wall Wood 164 0 069 R-21 R-0 0 165 An Wall Wood 587 0.069 R_21 R-0.0 255 gQ Roof Wnnd 664 _n n24 R_38 R-7 0 n n Wall Wnnd 187 0 069 R_21 R-0 0 7.5,9.Q Wall Wnnd 3R5 n 069 R-71 R -n n 165 A0 Total Conditioned Floor Area: 4,933 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 4,933 ft2 Average Ceiling Height: 12.5 ft Number of Dwelling Units: 1.00 Number of Stories: 1 # of Units Zone Type SIPPping Living Sleeping Thermostat Type SIe-pingStaL I i�iingStat Sles,pong, tat Vent Hgt. Area —n1 2 n/a n/a Gains Condition Y / N Status JA IV Reference Location / Comments New n7 -A17 Ma:;ter Ste ( nne 1) New 09-A6 Maater Ste (Zone 1) New 09-A6 Mader Ste (Zone 1) New 09-A6 Ma der Ste(Zone 1) New 09-A6 M;;;ter Ste (Zone 1) New 02-Al2 [west Ste (Zone ) New 09-A6 Guast StP ( nnP 2) New 09-A6 GuPst StP ( nnP 2) New 09-A6 Guest Ste (Zone ) New 02-Al2 Liv O/Din/Theater (7-1) New 09-A6 I ivJ(it/nin/ThPatPr (7-3) New 09-A6 Livltit/DinlTheater (7-1) New 09-A6 LlviGt/ M/Theater (7-3) New 09-A6 LivJ(i MMITheater (7-3) New 02-Al2 Bedroom 2 & 3 ( one 4) New 09-A6 Bedroom 2 & 3 ( nne 4) New 09-A6 Redrnnm 7 & 3 (7nne 4) EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:3 of 25 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Title 11/21/2006 Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 1 Window Right (N) 138 058 116_A_0_53 2 Window Right (N) 13.8 0.580 116-A 0.53 3 Window Right (N) 4.0 0.580 116-A 0_53 4 Window Right (N) 20.0 0.580 116-A 0.53 5 Window Right (N) 20.0 0.580 116-A 0_53 6 Window Rear (W) 27.0 0.580 116-A 0_53 Z Window Rear (W) 47.3 0_580 116-A -DM 8 Window Rear (W) 27.0 0.580 116-A 0.53 6 Window Rear (W) 4.0 0_580 116-A 0_53 10 Window Right (N) 13.8 0.580,16-A 0.53 11 Window Right (N) 13.8 0.580 116-A 0_53 12 Window Right (N) 4.0 0.580 116-A 0_53 13 Window Front (E) 20.0 0_580116-A _GM 14 Window Right (N) 27.5 0.580 116-A 0_53 15 Window Right (N) 11.3 0.580 116-A 0_53 116 Window Front (E) 20.0 0.580 116-A 0_53 17 Window Front (E) 36.0 0.580 116-A 0_53 18 Window Front (E) 31.5 0.580 116-A 0.53 1.Q Window Front (E) 36.0 0.58 11 6-A 116-B145 4D_ New Douhle Non Metal Tinted Master Ste (Zone 1) 116-B 345 90 New Double Non Metal Tinted Master Ste (Zone 1) 116-B 345 90 New Double Non Metal Tinted Master Ste (Zone 1) 116-B 345 90 New Double Non Metal Tinted Master Ste (Zone 1) 116-B 345 90 New Double Non Metal Tinted Master Ste (Zone 1) 116-B 255 90 New Double Non Metal Tinted Master Ste (Zone 1) 116-B 255 90 New Double Non Metal Tinted Master Ste one 1) 116-B 255 90 New Double Non Metal Tinted Master Ste (Zone 1) 116-B 255 90 New Double Non Metal Tinted Master Ste (Zone 1) 116-B 345 90 New Double Non Metal Tinted Guest Ste (Zone 2) 116-B 345 90 New Double Non Metal Tinted Guest Ste (Zone 2) 116-B 345 90 New Double Non Metal Tinted Guest Ste (Zone 2) 116-8 75 _RQ New Double Non Metal Tinted Guest Ste (Zone 2) 116-B 345 90 New Double Non Metal Tinted Liv/Kit/Din/Theater (Z-3) 116-B 345 90 New Double Non Metal Tinted Liv/Kit/Din/Theater (Z-3) 116-B 75 90 New Double Non Metal Tinted Liv/Kit/Din/Theater (Z-3) 116-8-R 75 90 New Double Non Metal Tinted Liv/Kit/Din/Theater (Z-3) 116-B 75 90 New Double Non Metal Tinted Liv/Kit/Dinlfheater (Z-3) 116-B 75_ 90 New Double Non Metal Tinted Liv/Kit/Din/Theater (Z-3) 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Area Thick. Heat Inside (sq (in.) Cap. Cond. R -Val. Window Overhang Left Fir Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 Concrete, Heavyweight Bug Screen 0.76 4.00 28 0_98 0 Bug Screen 0.76 _ Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 8.0 2.5 6.0 0.1 6.0 6.0 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Type Area Thick. Heat Inside (sq (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments Concrete, Heavyweight 560 4.00 28 0_98 2 26-A1 New (Vaster Ste (Zone 1) / Slab on Grade Concrete, Heavyweight 305 4.00 28 0_98 0 26-A1 New Master Ste (Zone 1) / Slab on Grade Concrete, Heavyweight 435 4.00 28 0.98 2 26-A1 New Guest Ste (Zone 2) / Slab on Grade Concrete, Heavyweight 90 4.00 28 0_98 0 26-A1 New Guest Ste (Zone 2) / Slab on Grade Concrete, Heavyweight 571 4.00 28 0.98 2 26-A1 New Lv/Kit/Din/Theater (Z-3) / Slab on -ra e PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 54 None No Insulation 26-A1 New Laster Ste (Zone 1) Slab Perimeter 25 None No Insulation 26-A1 New (Waster Ste (Zone 1) lab Perimeter 57 None No Insulation 26-A1 New Guest Ste (Zone 2) tab Perimeter 16 None No Insulation 26-A1 New Guest Ste (Zone 2) Slab Perimeter 75 None No Insulation 26-A1 New Liv/Kit/Dinlrheater (Z-3) EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Paae:4 of 25 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Chapman Residence 11/21/2006 oject Title Date FENESTRATION SURFACES # Type Area U -Factor' SHGCZ True Cond. Azm. Tilt Stat. Glazing Type Location/ Comments 22Q 21 Winnow Window Left Left (S) (S) go 9.0 0_580 116_A 0_53 116_B 165 gyp_ New Double Non Metal Tinted 0.580 116-A 0.53 116-B 165 90 New Double Non Metal Tinted Liv/Kit/Din/Theater (Z-3) Liv/Kit/Din/Theater (Z-3) 22 Window Rear (W) 13.5 0.580 116-A 0.53 116-B 255 90 New Double Non Metal Tinted Liv/Kit/Din/Theater (Z-3) 23 Window Rear (W) 11.3 0.580 116-A 0.53 116-B 255 90 New Double Non Metal Tinted Liv/Kit/Dinrrheater (Z-3) 24 Window Rear (W) 200.0 0.800 NFRC 0_39 NFRC 255 90 New Double Metal Tinted Liv/Kit/Dinrrheater (Z-3) 25 Window Rear (W) 4.0 0.580 116-A 0_53 116-B 255 90 New Double Non Metal Tinted Liv/Kit/Dinrrheater (Z-3) 2E Window Rear (W) 4.0 0.580116 0.53 116-B 255 90 New Double Non Metal Tinted Liv/Kit/Dinrrheater (Z-3) 27 Window Rear (W) 4.0 0.580 116-A 0.53 116-B 255 90 New Double Non Metal Tinted Liv/Kit/Din/Theater (Z-3) 2a Window Left (S) 40.0. 0.58 11 6-A -Q-U 116-B 165 90 New Double Non Metal Tinted Bedroom 2 & 3 one 4) ?,Q Window Left (S) 4.0 0_580 116-A _0_53 116_B 165 90 New Double Non Metal Tinted Bedroom 2 & 3 (Zone 4) 30 Window Left (S) 4.0 0.580 116-A 0_53 116-B 165 90 New Double Non Metal Tinted Bedroom 2 & 3 (Zone 4) 31 Window Left (S) 40.0 0.580 116-A 0.53 116-B 165 90 New Double Non Metal Tinted Bedroom 2 & 3 (Zone 4) 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1166. INTERIOR AND EXTERIOR SHADING Area Thick. Heat Inside JA IV Reference Condition Location/ Type Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 0_98 0 26-A1 New 21 Bug Screen 0.76 4.00 28 0_98 2 22 Bug Screen 0.76 Concrete, Heavyweight 136 4.00 28 Bug Screen 0.76 _ 4.5 2.5 .10.0 _ 0.1 10.0 10.0 _ Bug Screen 0.76 8.0 25.0 10.0 0.1 10.0 10.0 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 9.0 9.0 6.0 0.1 6.0 6.0 THERMAL MASS FOR HIGH MASS DESIGN PERIMETER LOSSES Type Area Thick. Heat Inside JA IV Reference Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight 2,308 4.00 28 0_98 0 26-A1 New Liv/Kit/Dinrrheater Z-3 / Slab on Concrete, Heavyweight 528 4.00 28 0_98 2 26-A1 New 1jSV8bm 2 & 3 Zone 4 / Slab on Concrete, Heavyweight 136 4.00 28 0_98 0 26-A1 New om 2 & 3 (Zone 4) / Slab on Grade PERIMETER LOSSES Type Length Insulation R -Val. Location JA IV Reference Condition Status Location/ Comments Slab Perimeter 99 None No Insulation 26-A1 New Liv/Kit/Dinrrheater (Z-3) Slab Perimeter 40 None No Insulation 26-A1 New Bedroom 2 & 3 (Zone 4) .diQab Perimeter 18 None No Insulation 26-A1 New Bedroom 2 & 3 (Zone 4) Run Initiation Time: 11121/06 11:01:13 Run Code: 1164135673 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:5 of 25 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Title HVAC SYSTEMS 11/21/2006 Date HVAC DISTRIBUTION Location Heatina Cooli HVAC -1 Ducted Ducted HVAC -2 & 3 Ducted Ducted HVAC -4 Ducted Ducted Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Heating Minimum Cooling Minimum 3ondition Thermostat Location Type Eff Type Eff Status Type HVAC -1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER New Setback HVAC -2 & 3 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER New Setback HVAC -4 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER New Setback HVAC DISTRIBUTION Location Heatina Cooli HVAC -1 Ducted Ducted HVAC -2 & 3 Ducted Ducted HVAC -4 Ducted Ducted Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Duct Condition Ducts Location R -Value Status Tested? Attic 4.2 New Yes Attic 4.2 New Yes Outdoors 4.2 New Yes WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status cr RE Loss (%) Ext. American G32 -75T75 -4N0*** Large Gas Recircfrime+Temp 2 75,100 75 New 0.80 2.53% 0.0 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Adc 1/2" In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: David Pierce Hohmann, Architect Address: 555 Anton Blvd., Suite 850 Costa Mesa, CA 92626 Telephone: (714) 241-3600 Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: gnature) (date) Documentation Author Name: Tim Scott Title/Firm: Scott Design & Title 24 Address: 77085 Michigan Dr. Pal DesertCA 92211 Telep on - 7 20 -47AO Z1 06 (signature) (date) I EneravPro 4.2 by EnerovSoft User Number: 6712 Job Number Pane•6 of 25 1 F- L L r L_ Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Title 11/21/2006 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design - Verify Thermal Mass: 560 sqft Covered Slab Floor, 4.00" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 305 sqft Exposed Slab Floor, 4.00" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 435 sqft Covered Slab Floor, 4.00" thick at Guest Suite HIGH MASS Design - Verify Thermal Mass: 90 sqft Exposed Slab Floor, 4.00" thick at Guest Suite The HVAC System "HVAC -2 & 3" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design - Verify Thermal Mass: 571 sqft Covered Slab Floor, 4.00" thick at Living/Kit/Din/Th eater HIGH MASS Design - Verify Thermal Mass: 2308 sqft Exposed Slab Floor, 4.00" thick at Living/Kit/DinfTheater The HVAC System "HVAC -4" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design - Verify Thermal Mass: 528 sqft Covered Slab Floor, 4.00" thick at Bedroom 2 & 3 HIGH MASS Design - Verify Thermal Mass: 136 sqft Exposed Slab Floor, 4.00" thick at Bedroom 2 & 3 The HVAC System "HVAC -4" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF4R Plan Field installation certificate. HVAC System "HVAC -1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC -1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. Ie The Cooling System "Carrier 38TDB060/58DLX110" includes credit for a 11.6 EER Condenser. A certified HERS rater must field verity the installation of the correct Condenser. The HVAC System "HVAC -2 & 3" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF - 4R. The HVAC System "HVAC -2 & 3" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Carrier 38TDB060158DLX110" includes credit for a 11.6 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "HVAC -4" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC -4" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Carrier 38TDB036/58DLX070" includes credit for a 11.8 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. v.LW 1 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Paae:7 of 25 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance • requirements from the Certificate of Compliance supercede the items marked with an asterisk (*) below. When this checklis- is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • • DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures *§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ R ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). �§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑X ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑X ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑X ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucet=_ certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems ine insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ Q ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:8 of 25 Mandatory Measures Summarv: Residential (Page 2, of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approa,,-h used. More stringent • compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. C� • DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if nos applicable. ENFORCE - NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Artice 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ X❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119id). R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requiremerds § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh ❑ or tape shall be used. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause ❑ reductions in the cross-sectional area of the ducts. dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Sectlon 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 119(d). ❑ ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipn--nt ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ❑X ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ © ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Tabe ❑ © ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determi led ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ EK ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility room.- shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section 1� 9(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Artice 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119id). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Sectlon 119(d). EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:9 of 25 Residential Kitchen Lighting Worksheet WS -5R hapma oject Title 11/21/2006 Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1) 35w Linear Fluorescent T5 Elec Yes X No 40.0 x 12 = 480 or (2) 26w Compact Fluorescent Triple 4 Pin Yes X No 74.0 x 8 = 592 or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or • Total A: 1,072 B: 0 COMPLIES IF A;-,, B YES ® NO ❑ C] EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Paae:10 of 25 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Al�z NAME DATE Chapman Residence 11/21/2006 STEM NAME FLOOR AREA HVAC -1 1,390 ENGINEERING CHECKS SYSTEM LOAD Output per System Total Output (Btuh) Output (Btuh/sgft) Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions (EATING SYSTEM PSYCHROMETRI 89,000 Total Room Loads 89,000 Return Vented Lighting 64.0 Number of Systems 1 600 COIL COOLING PEAK I OIL HTG. PEAK Hestina Svstem CFM Sensiblel L=tent I I CFM I Sensible 0 0 Output per System Total Output (Btuh) Output (Btuh/sgft) Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions (EATING SYSTEM PSYCHROMETRI 89,000 Total Room Loads 89,000 Return Vented Lighting 64.0 26.0 of 69.0 of 69.0 of 14 .24 Outside Air Q 0 cfm Supply Fan Heating Coil 2025 cfm 69.0 of 1,124 Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 733 600 22,354 59,000 59,000 4.9 42.4 282.7 26.0 of 69.0 of 69.0 of 14 .24 Outside Air Q 0 cfm Supply Fan Heating Coil 2025 cfm 69.0 of 1,124 24,975 733 600 22,354 0 3,001 2,063 0 0 0 0 0 0 0 0 0 3,001 2,063 30.g77 733 26 481 L,Uzo 2,025 Carrier 38TDB060/58DLX110 43,999 6,689 89,000 1.46 411.9 o.9 Total Adjusted System Output 43,999 6,689 89,000 (Adjusted for Peak Design Conditions) 0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 105.0 of k Return Air Ducts `S Supply Air Ducts 104.0 of ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 110.0/72.5OF 77.5/62.2OF 77.5/62.3OF 55.0/53.8OF O 14S S ipply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 56.4 / 54.3 of 2025 cfm 44.4% R.H. ROOMS 77.5/62.2 of 76.1 / 61.7 of �% Return Air Ducts `i EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:11 of 25 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Chapman Residence 11/21/2006 STEM NAME FLOOR AREA HVAC -2 & 3 2,879 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 1,794 33,059 844 35,726 0 3,973 3,298 0 0 0 0 0 0 0 0 0 3,973 3,298 41 016 Carrier 38TDB060/58DLX110 82,597 18,431 Total Adjusted System Output 82,5971 18,431 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.2 of 69.2 of n 110.5 of - I Outside Air 0 cfm Supply Fan Heating Coil 4050 cfm 69.2 of 10.0/72.5 OF 75.9/62.0 OF 75.9/62.1 OF 56.8/55.0 OF Outside Air 0 0 cfm Supply Fan Cooling Coil 4050 cfm 75.9 / 62.0 of COOT h Return Air Ducts � 42321 178,000 178,000 Jan 12 am rj Supply Air Ducts 109.8 of ROOMS 70.0 of Supply Air Ducts 57.7 / 55.3 of 47.2% R.H. ROOMS 75.0 / 61.7 of EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page 12 of 25 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Chapman Residence 11/21/2006 STEM NAME FLOOR AREA HVAC -4 664 EATI 7 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 595 10,751 436 198 8,811 0 1,292 813 0 0 0 0 0 0 0 0 0 1,292 1 813 13,335 436 Carrier 38TDBO36/58DLX070 24,266 6,738 Total Adjusted System Output 2x,266 6,738 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm 26.0 of 69.4 of 69.4 of E 112.40F Outside Air 0 cfm Supply Fan Heating Coil 1200 cfm 69.4 of 10,4371 55,000 55,000 Jan 12 am Supply Air Ducts 111.8 of ROOMS 70.0 of Return Air Ducts I ICOOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I 110.0/72.5OF 79.0/63.3OF 79.0/63.3OF 60.0/56.4OF O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 61.0 / 56.7 of 1200 cfm 43.4% R.H. ROOMS 79.0/63.3 of 78.0 / 62.9 of Return Air Ducts EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 13 of 25 ROOM LOAD SUMMARY PROJECT NAME DATE Chapman Residence 11/21/2006 STEM NAME FLOOR AREA HVAC -1 1,390 ROOM LOAD SUMMARY PAGE TOTAL 1 1,124 24,975 733 600 22,354 i TOTAL 1 1,124 24,975 733 600 22,354 EnergyPro By EnergySoft User Number: User Job Number: Page: 14 of 25 ROOM COOLING PEAK COIL COOLING FEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE -LATENT CFM SENSIBLE Master Ste Zone 1 Master Suite 1 798 16,990 220 798 16,990 220 385 14,349 Guest Ste (Zone 2) Guest Suite 1 326 7,985 513 326 7,985 513 215 8,005 PAGE TOTAL 1 1,124 24,975 733 600 22,354 i TOTAL 1 1,124 24,975 733 600 22,354 EnergyPro By EnergySoft User Number: User Job Number: Page: 14 of 25 ROOM LOAD SUMMARY PROJECT NAME Chapman Residence DATE 11/21/2006 STEM NAME HVAC -2 & 3 FLOOR AREA 2,879 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING FEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Liv/Kit/Din/Theater Z-3 Living/Kit/Din(fheater 1 1,794 33,069 1 1,794 33,069 1 844 35,726 PAGE TOTAL 1 1,794 33,069 1 844 35,726 TOTAL 1 1,794 33,069 1 844 35,726 EnergyPro By EnergySoft User Number: User Job Number: Page: 15 of 25 ROOM LOAD SUMMARY PROJECT NAME Chapman Residence DATE 11/21/2006 STEM NAME HVAC -4 FLOOR AREA 664 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Bedroom 2 & 3 Zone 4 Bedroom 2 & 3 1 595 10,751 436 595 10,751 436 198 8,811 I I PAGE TOTAL TOTAL 1 595 10,751 436 198 8,811 1 595 10,751 436 198 8,811 EnergyPro By EnergySoft User Number: User Job Number: Page: 16 of 25 ROOM HEATING PEAK LOADS roject Title Date a man Residence 11/21/2006 Room Information Desi n Conditions Room Name Master suite Time of Peak Jan 12 am Floor Area 865 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value pT of Btu/hr 19.2x6.1 865.0 x x X X X X X X x X X X X X X x X x x X x X X x X X X X X X X X X X X x X X X 0.0240 x X X X X X X x X X x X X X X x x x x X X X X X X X x x X x X x X X X x x x X 44 = = = = = = = = = = = = = = = = = = = = = = = = 915 517.4 0.0690 44 1,571 13.8 0.5800 44 352 13.8 0.5800 44 352 4.0 0.5800 44 102 20.0 0.5800 44 510 20.0 0.5800 44 510 160.0 0.0690 44 486 180.0 0,0690 44 546 239.7 0.0690 44 728 27.0 0.5800 44= 47.3 0.5800 44 1,207 27.0 0.5800 44 689 4.0 0.5800 44= 102 perimeter = 54k 0.7300 44=1 734 perimeter = 25.0 0.7300 44 803 Items shown with an astensk ((-)) denote conduction through an interior surface to another room. Page Total: 11,2971 Infiltration: I1 1.001 x 1.064 x 865 x 13.00 x 0.348 / 6] x 44 = 3 051 chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 14,349 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 17 of 25 ROOM HEATING PEAK LOADS roject Title Date a man Residence 11/21/2006 Room Information Desi n Conditions Room Name Guest Suite Time of Peak Jan 12 am Floor Area 525 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value -'�T of Btu/hr R-38 Roof R.30.2x14.16 R-21 Wall W.19.24.16 Double Non Metal Tinted Double Non Metal Tinted Double Non Met;;l Tinted R-21 Wall W.19.2x6.16 Double Non Metal Tinted R-21 Wall W.19.24.16 Slah Slab -On -Grade 525.0 X X X X X X X x X x x x X x X x x X X X X X X x X x x X x x X X x X x X x x X 0.0240 X X X X X X X X X X x X X X x X X X x X X x X X X x x x x x x X x x X X X X I X 44 = = = = = = = = = = = = = = = = = = 555 222.4 0.0690 44 675 13.8 0.5800 44 352 13.8 0.5800 44 352 4.0 0.5800 44 102 178.0 0.0690 44 540 20.0 0.5800 44 510 258.0 0.0690 44 783 perimeter - 57.0 0,7300 44 1,831 perimeter = 16.0 0.7300 44 514 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: I 6,2161 Infiltration: r 1.00 1 X 1.064 X 525 X 10.20 x 0.428 / 60] X 44 = 1 789 schedule Air Sensible Area Ceiling Height ACH Z`T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 8,005 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 18 of 25 ROOM HEATING PEAK LOADS ro.ect Title Date ME a man Residence 111/21/2006 Room Information Desicin Conditions Room Name Time of Peak Jan 12 am Floor Area 2,879 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area LI -Value ,!�,T of Btu/hr 1 2,879.0 X X X X X X x X X X X X X X X X X X x x X x x x X X X X X X X X x X X X X X X 0.0240 X X X X x X x x x X X x X X x X X x x X X x X X x X X X X X X X X X X X X X X 44 = = = = = = = = = = = = = = = = = = = 3,044 360.2 0.0690 44 1,094 27.5 0.5800 44 702 11.3 0.5800 44 288 323.5 0.0690 44 982 20.0 0.5800 44 510 36.0 0.5800 44 919 31.5 0.5800 44 804 44 919 164.0 0.0690 44 498 9.0 0.5800 44=930 9.0 0.5800 44 230 587.2 0.0690 44 1783 13.5 0.5800 44= 345 11,1 0.5800 44=288 200.0 0.8000 44 7,040 44 102 4.0 0.5800 44=102 4.0 0.5800 44 102 perimeter = 75.0 0.7300 44 2.409 perimeter = 99& 0,7300 44 3180 I= items shown with an asterisk (-) denote conaucuon through an interior sunace to another room. page Total: 25,570 Infiltration: r 1.001 X 1.064 x 2879 x 13.20 X 0.342 / 60] X 44 = 10 156 schedule Air Sensible Area Ceiling Height ACH p- Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 35,726 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 19 of 25 ROOM HEATING PEAK LOADS roject Title Date ha man Residence 11/21/2006 Room Information Desi n Conditions Room Name Bedroom 2 & 3 Time of Peak Jan 12 am Floor Area 664 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value Z�T of Btu/hr IDouble Non Metal Tinted I 664.0 X X x x X X X x X x x X X X X X X X X X X X X X X x X x X X X X X x x X x X X 0.0240 X X X X x X X x X X X X X X X X x X X x x X X X X X X X X X X X X X x X X X X 44 = = = = = = = = = = = = = = = = = = = 702 187.0 0.0690 44 568 385.0 0.0690 44 1,169 40.0 0.5800 44 1,021 4.0 0.5800 44 102 4.0 0.5800 44 102 40.0 0.5800 44 1,021 perimeter = 40.0 0.7300 44 1,285 perimeter = 18& 0,7300 44 578 Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 6 547 Infiltration: 1.00 x 1.064 x 664 x 11.00 x 0.397 / 60] x 0 = 2 263 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 8,811 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 20 of 25 RESIDENTIAL ROOM COOLING LOAD SUMMARY roject Title Date a man Residence 11/21/2006 Room Information Desi n Conditions Room Name: Master Suite Outdoor Dry Bulb Temperature: 11 1O Floor Area: 865 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 75 of Outdoor Daily Range: 340F vNuyue Quriauvb R-38 Roof R.30.2x14.16 R-21 Wall W.19.24.16 R-21 Wall (W.19.2x6.16) IR -21 Wall (W.19.2x6.16) I Orientation Area X X X X X X X X X X X x U -Factor X X X X X X X X X X x x CLTD 1 = = = = = = N 865.0 0.0240 56.0 N 517.4 0.0690 26.6 E 160.0 0.0690 31.7 S 180.0 0.0690 27.7 W 239.7 0.0690 32.3 31.4 20.0X 37.1= N 0.0X 31.4 20.0x 37.1= W 0.0x 31.4+ 27.0Y 61.1= W 0.0x 31.4+ 47.3Y 61.1= W 0.0x 31.4+ 27.0X 61.1= W 0.0 31.4 4.0 1. 61.- Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration • D D A C 3 5 Nage I otal Orientation Shaded Area x x x x x GLF + + + + + + + Unshaded Area X X x x Page GLF = = = N 0.0x 31.4 13.8) 37.1= N 0.0 31.4 13.8 37.1 N 0.0X 31.4+ 4.0X 37.1= N 0.0x 31.4 20.0X 37.1= N 0.0X 31.4 20.0x 37.1= W 0.0x 31.4+ 27.0Y 61.1= W 0.0x 31.4+ 47.3Y 61.1= W 0.0x 31.4+ 27.0X 61.1= W 0.0 31.4 4.0 1. 61.- Total Btu/hr 1,164 950 350 344 535 3342 Btu/hr Internal Gain Btu/hr Occu ants 2 X Occupants X 230 Btuh/oCC. = 460 P P E ui ment 1 X Dwelling Units X 1,6001 Watts/sqft = 1,6001 Infiltration: 1.064 x 1.19 X 54.81 X = 2 497 Air Sensible CFM ELA ZT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,990 Latent Gain Btu/hr Occu ants F 21 x Occupants X 2001 Btuh/oCC. = 400 Infiltration: 4 771 x 1.19 x 54.81 x 0.00058 = 180 Air Latent CFM ELA pw • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 220 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:21of 25 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date ha man Residence 111/21/2006 Room Information Desi n Conditions Room Name: Guest Suite Outdoor Dry Bulb Temperature: 111OF Floor Area: 525 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 780F Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr • IR -21 Wall (W.19.2x6.16) I N 525.0 X X X X X X x X X X X x 0.0240 X X X X X X X X X X X X 56.0 = = = = = N 222.4 0.0690 26.6 E 178.0 0.0690 31.7 S 258.0 0.0690 27.7 31.4+ 13.8X 37.1= 512 N 0.0x 31.4+ 4.0X 37.1= 148 E 7.8 31.4 12.2 58.1 955 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration A Page Total Orientation Shaded Area X x x X- x x x x GLF + + + + + + + + + Unshaded Area X x x x x x x x Page GLF = = = = = = = = Btu/hr N 0.0x 31.4 13.8X 37.1= 512 N 0.0X 31.4+ 13.8X 37.1= 512 N 0.0x 31.4+ 4.0X 37.1= 148 E 7.8 31.4 12.2 58.1 955 Total 2127 Internal Gain Btu/hr Occu ants 4 X Occupants x 230 Btuh/oCC. = 920 P P E ui ment 1 x Dwelling Units x 1,6001 Watts/sgft = 1.6001 Infiltration: 1.064 X 1.15 X 33.26 x = 1342 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7985 Latent Gain Btu/hr Occu ants 0 X Occupants X 2001 Btuh/oCC. = 800 Infiltration: 4 771 x 1.15 x 33.26 x 0.00158 = 287 Air Latent CFM ELA pW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 513 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 22 of 25 RESIDENTIAL ROOM COOLING LOAD SUMMARY roject TitleDate a man Residence 11/21/2006 Room Information Desi n Conditions Room Name: Living/Kit/Din/Theater Outdoor Dry Bulb Temperature: 11 1O Floor Area: 2,879 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 75 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr • IR -21 Wall (W.19.2x6.16) I 19.2x6.1 N 2,879.0 x X X X X x x x X X X x 0.0240 X X X X X x x x X x X X 56.0 N 360.2 0.0690 26.6 E 323.5 0.0690 31.7 S 164.0 0.0690 27.7 W 587.2 0.0690 32.3 20.0X 58.1 E 0.0x 31.4+ 36.0X 58.1 E 0.0 31.4 31.5 58.1 E 0.0x 31.4+ 36.0X 58.1 S 0.0x 31.4+ 9.0x 35.6 S 0.0x 31.4+ 9.0x 35.6 W Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration G E 16 C 1 C F F B E Nage I otal Orientation Shaded Area X X x X x GLF + + + +0.0 + Unshaded Area X X X x x GLF N 0.0X 31.4+ 27.5x 37.1 N 0.0 31.4 11.3 37.1 E 0.0x 31.4+ 20.0X 58.1 E 0.0x 31.4+ 36.0X 58.1 E 0.0 31.4 31.5 58.1 E 0.0x 31.4+ 36.0X 58.1 S 0.0x 31.4+ 9.0x 35.6 S 0.0x 31.4+ 9.0x 35.6 W 0.0 31.4 13.5 61. W 11.3 31.4 61.1 Page Total 3,874 661 707 313 1,310 6 865 Btu/hr Internal Gain Btu/hr Occu ants 3 X Occupants X 230 Btuh/occ. = 690 p P E ui ment 0 X Dwelling Units x 1,6001 Watts/sgft = 0 Infiltration: 1.064 x 1.19 x 182.41 x = 8,309 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 33,069 Latent Gain----- Btu/hr Occu ants X Occupants x 200 BtUh/OCC. = 600 Infiltration: 4 771 x 1.19 x 182.41 x 0.00058 = 599 Air Latent CFM ELA pw • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 23 of 25 RESIDENTIAL ROOM COOLING LOAD SUMMARY roject TitleDate ha man Residence 11/21/2006 Room Information Desicin Conditions Room Name: Living/Kit/Din/Theater Outdoor Dry Bulb Temperature: 111OF Floor Area: 2,879 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 75 of Outdoor Daily Range: 340F 0 opaque ourraces Orientation Area U -Factor CLTD 1 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Wind Page Total Btu/hr _ 0 Orientation x x x x x x x x x x + + + + + + + + + + + Unshaded Area Y. x x x _ M X1 x = = = = _ _ I= x W 200.0 30.2 x 52.1 x W 0.0x 31.4 x 61.1= x W 0.0x 31.4 x 61.1= x W 0.0x 31.4 x 61.1= x x x x x x x x x x x x x Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Wind Page Total Btu/hr _ 0 Orientation Shaded Area x x x x x x x x GLF + + + + + + + + + + + Unshaded Area Y. x x x _ M X1 GLF = = = = _ _ I= Btu/hr W 200.0 30.2 0.0 52.1 6,040 W 0.0x 31.4 4.0X 61.1= 245 W 0.0x 31.4 4.0Y 61.1= 245 W 0.0x 31.4 4.0X 61.1= 245 Page Total Internal Gain Btu/hr Occu ants 3 x Occupants x 230 Btuh/occ. = 690 E ui ment 0 X Dwelling Units x 1,6001 Watts/sqft = 1 01 Infiltration: 1.064 x 1.19 x 182.41 x = 8 309 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 33,069 Latent Gain Btu/hr Occupants 0 X Occupants x 200 Btuh/occ. = 600 Infiltration: 4 771 x 1.19 X 182.41 X -0.00058 = 599 Air Latent CFM ELA pW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 24 of 25 RESIDENTIAL ROOM COOLING LOAD SUMMARY ro�ua'-p'man Date Residence 11/21/2006 Room Information Desicin Conditions Room Name: Bedroom 2 & 3 Outdoor Dry Bulb Temperature: 11 1O Floor Area: 664 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F Opaque Surfaces IR -21 Wall (W.19.2x6.16) I Orientation Area X X X X X X X X X X X X U -Factor X X X X X X X X X X X X CLTD 1 N 664.0 0.0240 77.0 E 187.0 0.0690 40.7 S 385.0 0.0690 39.7 0.0x 38.0+ 4.0X 54.3= 217 S 0.0x 38.0+ 4.0X 54.3= 217 S 40.0 38.0 0.0 54.3 1,519 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Page Total Btu/hr 1,229 525 1,054 2 807 Orientation Shaded Area x x x x x x x x GLF + + + + + + + + Unshaded Area a X_ - x x x GLF = _ - = = = Btu/hr S 0.0x 38.0+ 40.0x 54.3= 2,174 S 0.0x 38.0+ 4.0X 54.3= 217 S 0.0x 38.0+ 4.0X 54.3= 217 S 40.0 38.0 0.0 54.3 1,519 1 Fage Total a 127 Internal Gain Btu/hr Occu ants 4 x Occupants x 230 Btuh/OCC. = 920 P P E ui ment 1 X Dwelling Units X 1,2001 Watts/Sgft = 1 200 Infiltration: 1.064 X 1.15 X 42.07 X I 1697 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,751 Latent Gain Btu/hr Occu ants E- -41 X Occupants X 2001 Btuh/oCC. = 800 Infiltration: 4 771 x 1.15 x 42.07 x 0.00158 = -364 Air Latent CFM ELA pw • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 436 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:25 of 25