Loading...
13-0913 (RER)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 c&ht 4 4 " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 13-00000913 Property Address: 53713 VIA PISA APN: 772-530-050-,- - Application description: REMODEL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 50000 Applicant: Architect or Engineer: cGotpAcfiot+2 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. Licensee Class: BLI 1 /� /\, j1 h fy1 Liceen/s�e NNo,.:^ ,76,2889 Date: 1 Z1 � I ` Contractor: \ V Y�I Ak CJ �.XN v` - OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY 1 hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPEPMIT Owner: PETER AND MOLLY CHAPMAN 227 20TH STREET STE. 100 NEWPORT BEACH, CA 92663 (949)300-3877 Contractor: FEDDERLY & ASSOCIATES 38747 NOPALES ROAD PALM DESERT, CA 92211 (760)773-5205 Lic. No.: 762889 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/24/13 D CITY ()F ! -A QUINTA WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EVEREST INS Policy Number 760000440081 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to becomc subjcct to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code; I shall forthwith omply with those provisions. Date: -1"1 Applicant: �/(Q°A WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. rt�� . , ' Date: "t ,� Signature (Applicant or Agent): VA� V 1' U/r/VI�N Application Number . . . . . 13-00000913 Permit. . ELECTRICAL 2013 Additional desc . Permit Fee . . . . 26.21 Plan Check Fee .00 Issue Date . . . Valuation . . . . 0 Expiration Date . . 3/23/14 Qty Unit Charge Per Extension 1.00 23.8300 LS ELEC FIXTURES, FIRST 20 23.83 1.00 2.3800 EA ELEC FIXTURES, ADD'L ---------------------------------------------------------------------------- 2.38 Permit REMODEL 2013 Additional desc . . Permit Fee . . . . 70.07 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/23/14 Qty Unit Charge Per Extension 1.00 48.6200 LS MISC REMODEL, 1ST 100 SF 48.62 1.00 21.4500 EA MISC REMODEL, ADDL 500 SF 21.45 ---------------------------------------------------------------------------- Special Notes and Comments DEMO EXISTING 414.4 sq.ft. DECK, AND ADD 553 sq. ft. PATIO & VERANDA NEW ELEC AND CEILING FAN. USING EXISTING STAIRWAY AND FIREPLACE. August 14, 2013 9:00:06 AM JJOHNSON. ---------------------------------------------------------------------------- Other Fees . . ... . . . . . BLDG STDS ADMIN (SB1473) 2.00 HOURLY PLAN CHECK 245.00 PLAN CHECK, ELECTRICAL 24.43 PLAN CHECK, REMODEL 150.15 STRONG MOTION (SMI) - RES 5.00 Fee summary Charged Paid Credited --------------------------------------------------------- Due Permit Fee Total 96.28 .00 .00 96.28 Plan Check Total .00 .00 .00 .00 Other Fee Total 426.58 .00 .00 426.58 Grand Total 522.86 .00 .00 522.86 LQPERMIT RECEIVED Bim#t� oLata �` "'JUL Cit -Quin yf "� . L �' 2 201� `i Building ff,Safety Division P.O. Box 1504,N-495 Calle Tam ic�OMM� OF LA UINTA La Quinta, CA 92253 - (760) 777-70 S NIT' DE R Lpp ME T Building Permit Application and Tracking Skeet Permit # Project Address: S3--71 Owner's Name:Mcwhi , A. P. Number: ? �. l Address: ?&A Legal Description: Cr�-((, - City, ST, Zip: 9 s— Contractor: � Tele hone: - P Address:3? 7 Project Description: City, ST, Zip:- " Telephone: M State Lic. # : City Lic. #: CO V L Arch., Engr., Designer: AT i Address: -5 s 3. 4 $ V City, ST, Zip: �al Telephone: hone: eConstruction SO���S 00-7773-50,105 - T Y Pe: Occupancy:anc . State to Lie. # ProJec P it one)• ewdd'n Alt er Repair Demo Name of Contact Person: Sq. t.:±, Stories: #Units: Telephone # of Contact Person: iP Esti ed V Project: Lf)1�[1Q APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING ?ERM1T FEES Plan Sets Plan Check submitted �/ Item Amount Structural Cales. Z Reviewed, ready for corrections ' Plan Check Dqposit Truss Calls. Called Contact Person Plan Check B lance Title 24 Calcs. Plans picked up ...-. Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"" Review, ready for correctio ssue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- "d Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees ky 81 ( PcaNs Rnc- P(4-js Rlv<n0Y To . zq iA 14 Ft 13,7 1 IJ T - .• 9. 0- BUILDING ENERGY ANALYST REPORT /COPE I PROJECT: Chapman Residence 53-713 Via Pisa, The Hideaway La Quinta, Ca 92253 Project Designer: Fedderly Associates 38-747 Nopales Road Palm Desert, Ca 92211 (760) 773-5205 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 Job Number: F LA 8/� I/201,3, & EC�l11NTA TY DEPT APF The EnergyPro computer program has been used to perform the calculatioh�Pumraiarjzbdg i hisIcomp�l' iafice report. This program has approval and is authorized by the California Energy Commission for use with jIboth the Residential and No esi9entiAG-P98 Building Energy Efficiency Standards. This program developedQf?nrerg ��f energysoft.com. EneravPro 5.1 by EnerovSoft User Number. 6712 RunCode: 200'08-21-T47162.12 ID: 1 L� 0 • I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 9 HVAC System Heating and Cooling Loads Summary 12 Room Load Summary 13 Room Heating Peak Loads 14 Room Cooling Peak Loads 16 CITY OF IA OUINTA BUILDING & SAFETY DEPT. FOR CONSTRUCTION EnergyPro 5.1 by EnergySoft Job Number: ID: —jUser Number: 6712 0 i • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Chapman Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family 0 Existing+ Addition/Alteration Date 8/21/2013 Project Address 53-713 Via Pisa, The Hideaway La Quint California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,567 Addition 634 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- if Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-30 4,933 Existing Wall Wood Framed R-19 3,177 Existing Slab Unheated Slab -on -Grade None 4,933 Perim = 364' Existing Roof Wood Framed Rafter R-30 634 New Wall Wood Framed R-21 835 New Slab Unheated Slab -on -Grade None 634 Perim = 78' New FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Right (N) 153.5 0.580 0.53 none none Bug Screen Existing Front (E) 116.1 0.580 0.53 none none Bug Screen Existing Left (S) 127.6 0.580 0.53 none none Bug Screen Existing Rear (Vl9 124.3 0.580 0.53 none none Bug Screen Existing Rear (Vlq 232.0 0.580 0.53 none none Bug Screen Removed Rear (M 250.0 0.530 0.39 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 3 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Existing HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing C WATER HEATING ()F LA UU 104 r r A Oty. Type Gallons.Min�Eff; g, Distribution Status _ .. r r:1 r-nNSl RUCTION i Ener Pro 5.1 by EnergySoft User Number. 6712 RunCode: 2013.08 -21T17:22:12__ ----J- Page 3 of 19 • • 0 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Chapman Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date $/21/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. I n n,I 11AIT BUR ING & SAFETY DEPT. APPROVED e FOR Uulv"b I HUU 1 r IV EnergyPro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-08-21 T17:22:12 ID: Page 4 of 19 I DAZE ___ tsr C J • • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Chapman Residence 1 ❑ Multi Family m Existing+ Addition/Alteration 8/21/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 3.64 3.26 0.38 Space Cooling 121.40 113.17 8.23 Fans 26.62 24.80 1.82 Domestic Hot Water 6.14 6.14 0.00 Pumps 0.00 0.00 0.00 Totals 157.80 147.36 10.44 Percent Better Than Standard: 6.6% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 75 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 902 116 Fuel Available at Site: Natural Gas (S) 1,383 128 Raised Floor Area: 0 (IM 1,056 374 Slab on Grade Area: 5,567 (N) 1,442 154 Average Ceiling Height: 11.8 Roof 5,567 0 Fenestration Average U -Factor: 0.56 TOTAL: 772 Average SHGC: 0.48 Fenestration/CFA Ratio: 13.9% REMARKS The Hideaway STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete Documentation Author Company Scott Design and Title 24, Inc, 1/2013 77-085 Michigan Drive Tim Scott Address g Name City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verificatiMon by an appr_oved'HERS rater. �O�NTA CAI �1r` �_ LA Designer or Owner (per Business & Professs ons-Ciode) SAFETY DEPT. Company Fedderly Associates � er ROV E Address 38-747 Nogales Road Name Lance Fedderly (;PNSTRUCTI Palm Desert, ca x2211 I 7FOR City/State/Zip Phone (60) 773-52 5 Signed License # Date DATE BY Ener Pro 5.1 by EnerqySoft User Number 6712 RbnCode-20.13-08-21_Ti7.:22�1.2-----4D: ' Page 5 of 19 C] • r: CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Chapman Residence Building Type O Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date $/21/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 4,933 0.032 R-30 0 0 Existing 4.2.1-A8 Existing Residence Wall 1,079 0.074 R-19 345 90 Existing 4.3.1-A5 Existing Residence Wall 786 0.074 R-19 75 90 Existing 4.3.1-A5 Existing Residence Wall 1,045 0.074 R-19 165 90 Existing 4.3.1-A5 Existing Residence Wall 2671 0.074 R-19 255 90 Existing 4.3.1-A5 Existing Residence Wall 290 0.074 R-19 255 90 Removec 4.3.1-A5 Existing Residence Slab 1,961 0.730 None 0 180 Existing 4.4.7-A1 Existing Residence Slab 2,972 0.730 None 0 180 Existing 4.4.7-A1 Existing Residence Roof 634 0.035 R-30 0 0 New 4.2.2-A17 Existing Residence Wall 210 0.069 R-21 345 90 New 4.3.1-A6 Existing Residence Wall 210 0.069 R-21 165 90 New 4.3.1-A6 Existing Residence Wall 415 0.069 R-21 255 90 New 4.3.1-A6 ExistingResidence Slab 634 0.730 None 0 180 New 4.4.7-A1 ExistingResidence FENESTRATION SURFACE DETAILS ID T e Area U -Factor SHGC Azm Status GlazingType Location/Comments 1 Window 4.0 0.580 NFRC 0.53 NFRC 345 Existing Existing Doors & Windows Existing Residence 2 Window 13.8 0.580 NFRC 0.53 NFRC 345 Existing Existing Doors & Windows Existing Residence 3 Window 13.8 0.580 NFRC 0.53 NFRC 345 ExistingExistingDoors & Windows ExistingResidence 4 Window 27.5 0.580 NFRC 0.53 NFRC 345 Existing Existing Doors & Windows Existing Residence 5 Window 20.0 0.580 NFRC 0.53 NFRC 345 Existing Existing Doors & Windows Existing Residence 6 Window 31.5 0.580 NFRC 0.53 NFRC 345 Existing Existing Doors & Windows Existing Residence 7 Window 4.0 0.580 NFRC 0.53 NFRC 345 Existing Existing Doors & Windows Existing Residence 8 Window 13.8 0.580 NFRC 0.53 NFRC 345 Existing Existing Doors & Windows Existing Residence 9 Window 13.8 0.580 NFRC 0.53 NFRC 345 Existing Existing Doors & Windows Existing Residence 10 Window 11.3 0.580 NFRC 0.53 NFRC 345 Existing Existing Doors & Windows Existing Residence 11 Window 21.6 0.580 NFRC 0.53 NFRC 75 Existing Existing Doors & Windows Existing Residence 12 Window 31.5 0.580 NFRC 0.53 NFRC 75 Existing Existing Doors & Windows Existing Residence 13 Window 31.5 0.580 NFRC0.53 NFRC 75 Existing Existing Doors & Windows Existing Residence 14 Window 31.5 0.580 NFRC 0.53 NFRC 75 Existing Existing Doors & Windows Existing Residence 15 Window 21.6 0.580 NFRC 0.53 NFRC 165 Existing Existing Doors & Windows Existing Residence 16 Window 40.0 0.580 NFRC 0.53 NFRC 165 Existing Existing Doors & Windows Existing Residence (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hat Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right Fin Hat Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 _ 10 Bug Screen 0.76 I f t -r . r i !e ^• + ' : '. 1- t 11 Bug Screen 0.76 12 Bug Screen 0.76 I i' I i .i w� ,'-A: = i T L- r- ' 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 1 I -i '. t 75 I ; i Jul i tV 16 Bug Screen 0.76 I M BY- - - -- -- Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-08a21T17:32.=12 Page 6 of 19 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Chapman Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1812112013 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area Ll -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 4.0 0.580 NFRC 0.53 NFRC 165 Existing Existing Doors & Windows Existing Residence 18 Window 4.0 0.580 NFRC 0.53 NFRC 165 Existing Existing Doors & Windows Existing Residence 19 Window 40.0 0.580 NFRC 0.53 NFRC 165 Existing Existing Doors & Windows Existin Residence 20 Window 9.0 0.580 NFRC 0.53 NFRC 165 Existing Existing Doors & Windows Existing Residence 21 Window 9.0 0.580 NFRC 0.53 NFRC 165 Existing Existing Doors & Windows Existing Residence 22 Window 4.0 0.580 NFRC 0.53 NFRC 255 Existing Existing Doors & Windows Existing Residence 23 Window 11.3 0.580 NFRC 0.53 NFRC 255 Existing Existing Doors & Windows Existing Residence 24 Window 31.5 0.580 NFRC 0.53 NFRC 255 Existing Existing Doors & Windows Existing Residence 25 Window 42.0 0.580 NFRC 0.53 NFRC 255 Existing Existing Doors & Windows Existing Residence 26 Window 4.0 0.580 NFRC 0.53 NFRC 255 Existing Existing Doors & Windows Existing Residence 27 Window 31.5 0.580 NFRC 0.53 NFRC 255 Existing Existing Doors & Windows Existing Residence 28 Window 232.0 0.580 NFRC 0.53 NFRC 255 Removed Existing Doors & Windows Existing Residence 29 Window 250.0 0.530 NFRC 0.39 NFRC 255 New New Patio Door Existing Residence (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin H t Wd Len H t LExt RExt Dist Len Right Fin Hat I Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Buq Screen 0.76 27 Bug Screen 0.76`- r- r 28 Bug Screen 0.76 t3O1LY1fOU tx �r• u=� r vim' ti 29 Bug Screen 0.76 A / w )K UWIVZ) I tiUJ - I QI' DATE -- _ - - By-- EnergyPro 5.1 by EnergySoft User Number: 6712kRanco-Je''2073-3 -7.77 7722. 7 ID: Page 7 of 19 • • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Chapman Residence Building Type © Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1812112013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built Existing HVAC Existing 1st Floor 4,933 56,730 2005 Addition 634 8,876 Totals 6341 4,9331 01 0 HVAC SYSTEMS System Name Qt . Heatin T e Nin. Eff. Cooling Type Min. Eff. Thermostat Type Status Existing HVAC 3 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Coolin Duct Location R -Value Ducts Tested? Status Existing HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing ❑ WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Existing DWH 2 Small Gas All Pipes Ins 65,000 75 0.72 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length (ft) c 0 Pipe Pipe Diameter Insul. Thick. Qty.FHP Plenum Outside G IT) rBuried;_ —ia- Qac ,. , Li � Q J I i'll � /4tength ,.S stem Name r3 vi a �. ', ._. n' J)NISTPI K -TION I DATE BY Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode.-2013j Page 8 of 19 C MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Chapman Residence Date 8/21/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. .-§1 18(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. 150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent LI -factor. 150(f): Air retarding wrap is tested labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. '§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 1121c . §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water -tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. -§1 50(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §150Q)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 1 50 ' 3A: Insulation is protected from damage, inc uding thatwduCtoJsunlijht m6sture\,eflui ymeni`maintenance and wind. §1 500)3A: Insulation for chilled water piping and refrigerant sucti011 es�nclu 98esd Vapor retardant`or:is-en osed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are cE rtified byAhe Solar Rath =and ,Certification Cokr oration. FOR CONSTRUCTION EnergyPro 5.1 by EnergySoft User Number: 6712 RunC 2 -3-08-21 T17:22:12 ID: Page 9 of 19 C • • -MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1R Project Name Date Chapman Residence 1812112013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements o UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 50(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes '.§1 ..unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150(m)10: Flexible ducts cannot have porous inner cores. §150(0): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with cperating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). -§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shal'Msp-no-more than .20. watts,of.power peLJ&ar foot of illuminated cabinet. L / f1.r_ I nG t i r� it i BUILDING & ISA!`ETY DEPT. A ED FOR CONSTRUCTION EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2013-08-21717:22:12 ID: I Page 10 of 19 • MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Chapman Residence 8/21/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CITY OF LA QUiNTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION EnergyPro 5.1 by EnergySoft User Number: 6712 RunCOe: 2013-08-21717:22:12 /D: Page 11 of 19 • • HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Chapman Residence Date 8/21/2013 System Name Existing HVAC Floor Area 5,567 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 COIL COOLING CFM Sensible Total Room Loads 3,015 70,210 Return Vented Lighting 0 Return Air Ducts 5,953 Return Fan 0 Ventilation F 0 0 Supply Fan 0 Supply Air Ducts 5,953 TOTAL SYSTEM LOAD 1 82,117 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output perSystem 75,000 4,914 1,340 68,850 Total Output Btuh 225,000 Output Btuh/s ft 40.4 4,892 Cooling System 0 Output perSystem 44,000 0 0 0 Total Output Btuh 132,000 4,914 0 Total 06tput Tons 11.0 4,892 Total Output Btuh/s ft 23.7 Total Output s ft/Ton 506.1 78,634 "Air System CFM perSystem 1,400 HVAC EQUIPMENT SELECTION - Airflow cfm 4,200 Existing Maytag HVAC 111,611 940 225,000 Airflow cfm/s ft 0.75 Airflow cfm/Ton 381.8 Outside Air % 0.0% Total Adjusted System Output 1 111,611 940 1 225,000 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air Ar 0 cfm 69 OF 69 OF 119 OF 119 OF Heating Coil Supply Fan 4,200 cfm 118 OF ROOM - 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 79/62°F 79!62°F 54/53°F 54/53°F Cooling Coil SvRPly Fan 55 / 53 OF 4 200 •cfm �I I OF LA QU14J2,°A ROOM BUILDING & SAFETY DEPT. �� () ,F^ 78/I62 OF - r e/ A_l F R CONSTRUCTION EnergyPro 5.1 by EnergySoft User Number: 6712 RunC0eUOr8-08-21717:22:12 „ ID: Page 12 of 19 • • ROOM LOAD SUMMARY Project Name Chapman Residence Date 8/21/2013 System Name Existing HVAC Floor Area 5,567 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Existing Residence Existing 1 st Floor 1 2,245 54,105 4,285 2,245 54,105 4,285 1,096 55,901 Addition 1 770 16,104 629 770 16,104 629 244 12,949 T -x / A mi !NTA ' Total includes ventilation load for zonal systems. BU.AG"E�fo�►LSAFE t3T015 '7b,2101 AtT-0,TAI i® h—,& 70,2 1,01 FOR CONSTRU I I 4,914 4,914 1,340 68,850 1,340 68,850 Ener Pro 5.1 by EnerqySoft User Number: 6712 Ru Code: 2013-08-21717:22:12 ID: Pae 13 of 19 LDATE ---- BY I C] • • ROOM HEATING PEAK LOADS Project Name Chapman Residence Date 8/21/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing 1st Floor Floor Area 4,933.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value AT 'F 0.0320 X 44 0.0740 X 44 0.5800 X 44 0.7300 X 44 X X X X X X X X X X X X X X X X X X X X X X X X X X X another room Page Total 1,-50j�X H0.30,,7 '/p60,\].TX eigh-f ' "'`'ACH� v � � V � � AT l_j� NG & SAFETY DEPT. IDnr_'� �R- = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-30 Roof 4,933.0 X 6,946 R-19 Wall (W. 19.2x6.16) 3,176.5 X X X X 10,343 Existing Doors & Windows 521.5 13,309 Slab -On -Grade perm = 364.0 11,692 X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to X 4,933 X Area Bteilt Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction 42,289 = 13,613 TOTAL HOURLY HEAT LOSS FOR ROOM Y Y 1`� V r— 55 901 C!1 ' `..' T_� ION EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code 2 13 &21717:22:12 ID: Page 14 of 19 • • • ROOM HEATING PEAK LOADS Project Name Chapman Residence Date 8/21/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Addition Floor Area 634.0 ft' Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to UU U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X x ®vED AT *F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 4a 42 Btu/hr R-30 Roof 634.0 0.0350 42 932 R-21 Wall (W.21.2x6.16) 835.0 0.0690 42 2,420 New Patio Door 250.0 0.5300 42 5,565 Slab -On -Grade perm = 78.0 0.7300 42 2,391 Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 [ O O Schedule Air Sensible Fraction through an interior surface X 634 A•ea OPPAPPR another room �' r y�-- r- �� 14.QOIX 0.248 �g H�eig�itG & `ACN—t LL Page Total l �1T A\ /'60 X I Y 3Er•' T , 11,308 = 1,641 TOTAL HOURLY HEAT LOSS FOR ROOM I Gr)R 0 ONSTRUUI i 12,949 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013ti 8,- ¢]'17:22:12 Page 15 of 19 C] 0 .7 I RESIDENTIAL ROOM COOLING LOAD SUMMARY I Chapman Residence 8/21/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing 1st Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 4:933.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF ODaaue Surfaces R-30 Roof R-19 Wall (W. 19.2x6.16) R-19 Wall (W. 19.2x6.16) R-19 Wall (W. 19.2x6.16) R-19 Wall (W. 19.2x6.16) Orientation Area X X X X X X X X X U -Factor X X X X X X X X CLTD' = = = = = = = = = 4,933.0 0.0320 56.0 1,078.5 0.0740 29.0 785.9 0.0740 31.7 1,045.4 0.0740 27.7 266.7 0.0740 32.3 31.3 27.5 48.3 0.0 31.3 20.0 48.3 0.0 31.3 31.5 JX 0.0 31.3 4.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fanacfratinn Window Window Window Window Window Window Window Window Window Orientation Btu/hr 2,314 1,842 2,140 638 1 15,7741 Shaded Area X X X X X X X X X GLF + + + + + + + + +1 Unshaded Area X X X X X }_ X X } GLF = = = = = = = = = 0.0 31.3 4.0 48.3 0.0 31.3 13.8 48.3 0.0 31.3 13.8 48.3 0.0 31.3 27.5 48.3 0.0 31.3 20.0 48.3 0.0 31.3 31.5 48.3 0.0 31.3 4.0 48.3 0.0 31.3 13.8 48.3 0.01 31.3 13.8 48.3 Page Total Btu/hr 193 667 667 1,329 966 1,522 193 667 1 6,8701 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 0.87 X 305.45 X 34 = 9,570 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 54,105 Latent Gain Occupants 4.0 Occupants X _ 200 Btuh/occ. _ FLA QUI NTA Infiltration: 4,771 X 0.87 X 305.45 „0.00276 _ Air Sensible CFM ELA a' I w ANG &SAFETY DEPT. Btu/hr 800 1 3,4851 I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 ono 1 4.2851 DATE BY • • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Chapman Residence 1 8/21/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing 1 st Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 4,933.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Dailv Range: 34 OF Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF 48.3 = 57.9 = 0.0 31.3 11.3 0.0 31.3 21.6 0.0 31.3 31.5 57.9 = 57.9 = 0.0 31.3 31.5 0.0 31.3 31.5 57.9 = 0.01 31.3 21.6 35.4 = 35.4 = 0.0 31.3 40.0 0.0 31.3 4.0 35.4 = 35.4 = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fpnpctratinn Window Window Window Window Window Window Window Window Window (E) (E) (E) (S) on Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF 48.3 = 57.9 = 0.0 31.3 11.3 0.0 31.3 21.6 0.0 31.3 31.5 57.9 = 57.9 = 0.0 31.3 31.5 0.0 31.3 31.5 57.9 = 0.01 31.3 21.6 35.4 = 35.4 = 0.0 31.3 40.0 0.0 31.3 4.0 35.4 = 35.4 = 0.0 31.3 4.0 Page Total Btu/hr 0 Btu/hr 546 1,251 1,825 1,825 1,825 765 1,417 142 14 9,7361 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 305.45 X 34 = 9,570 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 54,105 Latent Gain Btu/hr Occupants 4.0 Occupants X i -7- �r`IT)( OF U 00 �Btch/occ! A = 800 & SAFETY DEPT. Infiltration: 4,771 X 0.87 X 305.45 Air Sensible CFM EWA C I.fY o v v X D'l11 ILO- Q276. (' V d.J �/ 3,485 FOR CONSTRUCTION TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 4.285 • rI • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Chapman Residence 1 8/21/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing 1st Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 4,933.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF e Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF = = = = = = 0.0 31.3 40.0 35.4 0.0 31.3 9.0 35.4 0.0 31.3 9.0 35.4 0.0 31.3 4.0 61.0 0.0 31.3 11.3 61.0 0.0 31.3 31.5 61.0 0.0 31.3 42.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded FanPstratinn Window Window Window Window Window Window Window Window Window Orientation Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = 0.0 31.3 40.0 35.4 0.0 31.3 9.0 35.4 0.0 31.3 9.0 35.4 0.0 31.3 4.0 61.0 0.0 31.3 11.3 61.0 0.0 31.3 31.5 61.0 0.0 31.3 42.0 0.0 31.3 4.0 0.0 31.3 31.5 Page Total Btu/hr 171 Btu/hr 1.417 319 319 244 689 1,921 2,561 244 1,921 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 305.45 X 34 = 9,570 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 54,105 Latent Gain _ Btu/hr Occupants 4.0 Occupants X UI I i �� 200Qur/de%TTA = 800 IJUILDING & SAFETY DEPT. Infiltration: 4,771 X 0.87 X 305.45 Oq.40276 PROVED r 3,485 Air Sensible CFM ELA I AW CONSTRUCTION TOTAL HOURLY LATENT HEAT GAIN FOR ROOM M 4,285 1 DATE ov w 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Chapman Residence 1 8/21/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Addition Outdoor Dry Bulb Temperature 112 °F Floor Area 634.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-30 Roof (N) 634.0 X 0.0350 X 56.0 = 1,243 R-21 Wall (W.21.2x6.16) (N) 210.0 X 0.0690 X 29.0 = 420 R-21 Wall (W.21.2x6.16) (S) 210.0 X 0.0690 X 27.7 = 401 R-21 Wall (W.21.2x6.16) (KO 415.0 X 0.0690 X 32.3 = 926 X X = X X = X X = X X = X J X I= Page Total 2,990 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (WM 0.0 X 25.1 + 250.0 X 46.9 = 11,735 x x - x x - x x - x x - x x - x x - x x - x x - Page Total 11,735 Internal Gain Btu/hr Occupants 0.0 Occupants X 230 Btuh/occ. = 0 Equipment 10.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.89 x 39.26 x 37 = 1,380 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,104 Latent Gain Btu/hr Occupants 0.0 Occupant(XI , 0 ` -BtUTi/'cC. = 0 '` T�` ( I i� A Infiltration: 4,771 X 0.89 X nX� �t 0r ��%00,3�6�.-FN DEPT. 629 Air Sensible � CFM ELIY"" AW APPROVED TOTAL HOURLY LATENT HEAT GAIN FOR ROW FORCONSTRUGHUN 629 EnergyPro 5.1 by Ener Soft User Number: 6712 unCode: 2013-08-21717:22:12 ID: Pae 19 of 19 DAIL— Ul