13-0133 (SFD)TihfP.O. BOX 1504^� VOICE (760) 777-7012
78-495 CALLE TAMPICO ✓ le -
FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 5/17/13
Application.Nur6er: 13-00000133 ;+ Owner:
Property Address: 53732 VIA PISA COASTAL REAL ESTATE INVEST
APN: 777-190-015- - - P.O. BOX 1144
Application description: DWELLING - SINGLE FAMILY DETACHED LA QUINTA, CA 92253
Property Zoning: LOW DENSITY RESIDENTIAL (760) 771-4722
Application valuation: 462407 k!f
Contractor:
Applicant: Architect or Engine SUN VISTA DEVELOPMENT CORP
P.O. BOX 1144
c)v AOUINTA LA QUINTA, CA 92247
FINANCE DEPT. (760) 771-4722
Lic. No.: 744091
--------------------------------------------------------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations:
Section 7000) of Division 3 of the Business and Professionals Cod , and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
License CI ss: B Licen No.: 744091 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
y ,, issued.
✓atr 0Z Contractor: _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
OWNER -BUILDER DECLA ION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1 _) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 903738513
I Certify that, in the performance of the work for whish this permit is issuad, I shall hot ympiny any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
^37000 of the Labor Cod , I sWall ADrThwith comp with those provisions.
44 Date:OVI Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAG IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
ofthis county to enter poo the above-mentioned property f msp ,ion urposas.
Date�� Signature (Applicant or Agent):
Application Number . . . 13-00000133
------ Structure Information NEW SFD
-----
Construction Type . .
. . . TYPE V, UNPROTECTED
Occupancy Type . .
. . . DWELLG/LODGING/LONG <=10
Other struct info . .
. . . CODE EDITION 2010
# BEDROOMS
4.00
FIRE SPRINKLERS YES
GARAGE SQ FTG
1091.00
PATIO SQ FTG
917.00
NUMBER OF UNITS
1.00
----------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
5177.00
Permit
BUILDING PERMIT.
Additional desc .
Permit Fee . . . .
1910.00 Plan Check Fee
1241.50
Issue Date . . . .
Valuation . . . .
462407
Expiration Date . .
11/13/13
Qty Unit Charge
Per
Extension
BASE FEE
639.50
363.00 3.5000
----------------------------------------------------------------------------
THOU BLDG 100,001-500,000
1270.50
Permit
ELEC-NEW RESIDENTIAL
Additional desc . .
Permit Fee . . . .
233.02 Plan Check Fee
58.26
Issue Date . . . .
Valuation . . . .
0
Expiration Date
11/13/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
5177.00 .0350
ELEC NEW RES - 1 OR 2 FAMILY
181.20
1091.00 .0200
ELEC GARAGE OR NON-RESIDENTIAL
21.82
1.00 15.0000
----------------------------------------------------------------------------
EA ELEC TEMPORARY POWER POLE
15.00
Permit GRADING PERMIT
Additional desc . .
Permit Fee . . . . 15.00
Issue Date'
Expiration Date 11/13/13
Plan Check Fee . . .00
Valuation . . . . 0
Qty Unit Charge Per Extension
BASE FEE 15.00
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL
LQPERD1IT
0
Application Number
Permit . . . MECHANICAL
Additional desc . .
Permit Fee . . . . 187.00
Issue Date . . . .
Expiration Date . . 11/13/13
13-00000133
Plan Check Fee . . 46.75
Valuation . . . . 0
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
24.00
BASE
FEE
15.00
1.00
9.0000
EA
MECH
FURNACE <=100K
9.00
3.00
11.0000
EA
MECH
FURNACE >100K
33.00
1.00
9.0000
EA
MECH
B/C <=3HP/100K BTU
9.00
3.00
16.5000
EA
TECH
B/C >3-15HP/>100K-500nTU
49.50
10.00
6.5000
EA
MECH
VENT FAN
65.00
1.00
----------------------------------------------------------------------------
6.5000
EA
MECH
EXHAUST HOOD
6.50
Permit . . .
Additional desc . .
Permit Fee . . . .
Issue Date . . . .
Expiration Date . .
PLUMBING
225.00
11/13/13
Plan Check Fee . . 56.25
Valuation . . . . 0
Qty Unit Charge
Per
Extension
BASE FEE
15.00
24.00
6.0000
EA
PLB FIXTURE
144.00
1.00
15.0000
EA
PLB BUILDING SEWER
15.00
2.00
7.5000
EA
PLB WATER HEATER/VENT
15.00
1.00
3.0000
EA
PLB WATER INST/ALT/REP
3.00
1.00
9.0000
EA
PLB LAWN SPRINKLER SYSTEM
9.00
12.00
.7500
EA
PLB GAS PIPE >=5
9.00
1.00
15.0000
EA
PLB GAS METER
15.00
----------------------------------------------------------------------------
Special Notes and Comments
5177 sf SFD.
TYPE V -B
W/
SPRINKLERS.
2010 CODES.
2013 DIF.
TUMF. ARCHITECT:
DAVID W. HELTON C-32640.
**PERMIT DOES
NOT INCLUDE
BLOCK WALLS,
FENCES,
SWIMMING POOLS, SPA,
BBQ'S
and DRIVEWAY
APPROACH**
----------------------------------------------------------------------------
Other Fees
. . . . .
.
. . . ART IN PUBLIC PLACES -RES
656.02
BLDG STDS ADMIN (SB1473)
19.00
DIF COMMUNITY CENTERS -RES
129.00
DIF CIVIC CENTER - RES
942.00
ENERGY.REVIEW FEE
124.15
DIF FIRE PROTECTION -RES
433.00
HOURLY PLAN CHECK
770.00
DIF LIBRARIES - RES
344.00
LQPERMIT
w
Application Number . . . . 13-00000133
----------------------------------------------------------------------------
Other Fees . . . . . . . . . MULTI -SPECIES (MSHCP) FEE 1254.00
DIF PARK MAINT FAC - RES 40.00
DIF PARKS/REC - RES 2048.00
STRONG MOTION (SMI) - RES 46.24
TUMF: RESIDENTIAL 1837.44
DIF STREET MAINT FAC -RES 116.00
DIF TRANSPORTATION - RES 2842.00
Fee summary Charged
Permit Fee Total 2570.02
Plan Check Total 1402.76
Other Fee Total 11600.85
Grand Total 15573.63
LQPEFNIIT
Paid Credited Due
.00 .00 2570.02
750.00 .00 652.76
.00 .00 11600.85
750.00 .00 14823.63
_- � uulctcv
P.O. BOX 1504
Building � � 78-495 CALLE TAMPICO
Address S3 73 Z V / A / S LA QUINTA, CALIFORNIA 92253
Owner
�as -% / RIC4 f.S �e �.n^v4 rr►e�
Mailing
Address 'Po QOX 7/41/1/
a Q�� hist "92253 b a -77/-'l
ntractCor
J�I1 V! S � / J � ✓sem_ �e,OI�'1c/9T'
K // 14'1�r vin �f
Zip p
9azs3- -9R) 7 7/-q 7 2
& Classif. 7 y y o 9 I Lic. #
Arch., Engr.,
Designer 1- 1-f.6.4 �y �
Address Tel.
/7y/ �s'V//L �vG�•
Cit zi Limi3 Z
t#&( YO
27 8a
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that 1 m licensed under rovisions of Chapter 9 (commencing with action
7000) of Divisi 3 he fines C de, and my license is in II fo a and
effect. ea
%3
SIGNATURE DATE
OWNER-BUILDERLARATION
I hereby affirm that I am exempt from th Contractor's License Law for the following
reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes-
sions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon and who does such work himself or through his own employees, provided
that such improvements are not intended or offered for sale. If, however, the building or im-
provement is sold within one year of completion, the owner -builder will have the burden of
proving that he did not build or improve for the purpose of sale).
O I, as owner of the property, am exclusively contracting with licensed contractors to construct
the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does
not apply to an owner of property who builds or improves thereon, and who contracts for such
projects with a contractor(s) licensed pursuant to the Contractor's License Law)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑ Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less).
I certify that in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to became subject to Workers' Compensation Laws of
California.
Date Owner
NOTICE TO APPLICANT.' If, alter making this Certificate of Exemption you should become
subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work
for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
WHITE = BUILDING DEPARTMENT
fir '///d%i
APPLICATION ONLY
BUILDING: TYPE CONST•5f'01 OCC. GRP.
A.P. Number 7 7:7 — / 9 01,
Legal Description -
Project Description
Minimum Setback Distances:
1 1t5ef sack frorn Ifinter Lin
FINAL
Issued by:—
Validated by:
Validation:
YELLOW = APPLICANT
Street Setback
Setback�om P
PINK = FINANCE
Sq. Ft. p0
Size
No.
Stories
No. Dw.
Units
New Add ❑ Alter ❑
Repair ❑ Demolition ❑
Estimated Valuation
PERMIT
AMOUNT
Plan Chk. Dep.
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
TOTAL
REMARKS
ZONE:
BY:
Minimum Setback Distances:
1 1t5ef sack frorn Ifinter Lin
FINAL
Issued by:—
Validated by:
Validation:
YELLOW = APPLICANT
Street Setback
Setback�om P
PINK = FINANCE
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
Ar4OUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:.
COMM/IND. AMOUNT:
DATE:
RECEIPT:
CHECK#:
7rnALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: LoastaLRea11ER tZInv, I !
Owner's Name: Coastal Real Estate Inv, Inc.
Project Address: 53-732 Via Pisa, La Quinta, CA
Project Description: New Single Family Dwelling
APN: 777-190-015 Tract #:
Type of Development: Residential XX1 Commercial
Total Square Feet of Building Area: 5,132 Sq. Ft.
Date: May 20, 2013
Phone No.
Lot #'s:
Industrial
Certification of Apptiicant/Owners: The person signing certifies that the above information is correca and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer.
Dated: �� /]� Signature:
************************************************,�r**********************
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code
17620
Number of Sq.Ft.
Amount per Sq.Ft.
Amount Collected
Gov. Code
65995
5,132
$3.20
$16,422.40
Project Agreement Existing Not Subject to Fee
Approval Prior to 1/1/87 Requirement
Building Permit Application Completed: Yes/No
By: Elsa F. Esqueda, Director of Facilities and Maintenance
Certificate issued by: Leticia Torres, Facilities Analyst
Note:
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FM AND STATEML?T%T OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day pa riod to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other arplicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as det4rmined by the School District, and up
to three (3) such extensions may be granted.
MV:c/mydocs'dcvlecsiccrtiiicatc ofcompliance Ibrm updated 3-2007 11/2010
05/20/2013 15:06 7607714922 SUNUISTA
FA�L -�160 �'6//
May 13, 2013
Mr. Rob Capetz
Coastal .Real Estate Investments, Inc.
PO Box 144
Iia Quinta, CA 92253
RE: Coastal #2/Lot 290 at 53732 Via Pisa
Final Design Review #3
PAGE 01/01
Dear Mr. Capetz:
The Hideaway Design Review Committee (DRC) reviewed and approved "the revised Final
Design submittal received for Lot. 290 on Via Pisa subject to the following comment being
addressed prior to the request -for Setback. Observation,
1. The request for encroachment at the Mechanical Room. could not be approved. Please
revise the mechanical room to fit within the allowable setbacks.
Please contact Brook Marshall at (760) 219-8057 or by email at Brook@dc.rr.com with any
questions or to schedule your Fre-Construction Meeting at the lot once a Building Permit has
been obtained.
Sincerely,
Hideaway Design Review Committee
cc; dim(�Flcltondcford.com
(;iugtnvo Magona
DRC File
PROUDLY SERVING THE
UNINCORPORATED AREAS
OF RIVERSIDE COUNTY
AND THE CITIES OF.
BANNING
BEAUMONT
CALIMESA
CANYON LAKE-
COACHELLA
DESERT HOT SPRINGS
EASTVALE
INDIAN WELLS
INDIO
LAKE ELSINORE
LA QUINTA
MENIFEE
MORENO VALLEY
PALM DESERT
PERRIS
RANCHO MIRAGE
RUBIDOUx CSD
SAN JACINTO
TEMECULA
WILDOMAR
BOARD OF
SUPERVISORS:
BOB BUSTER
DISTRICT 1
JOHN TAVAGLIONE
DISTRICT 2 .
JEFF STONE
DISTRICT 3
JOHN BENOIT
DISTRICT 4
MARION ASHLEY
DISTRICT 5
RIVERSIDE COUNTY FIRE DEPARTMENT
IN COOPERATION WITH
THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION
77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 92211-4131 • Phone (760) 863-8886
• Fax(760)863-7072
www.rvcfire.org
September 18, 2013
Holland Fire
1600 Meadowlark Way
Roseville, CA 95661
Re: Residential Fire Sprinkler Plan Review
LAQ-13-RS-066 53-732 Via Pisa La Quinta, CA
The sprinkler plans you submitted for the above referenced project have been reviewed by
Riverside County Fire Department Planning & Engineering personne and are approved with
the following conditions:
A minimum of one spare fire sprinkler head of each type and temperature rating along with a
sprinkler wrench should be located in a spare head cabinet at the system riser or other
approved location.
Permanently marked identification signs shall be attached to all control valves.
A warning sign, with minimum '/ inch letters, shall be affixed adjacert to the main shutoff valve
and shall state the following:
WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a
fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler
system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system
without a review of the fire sprinkler system by a fire protections: specialist. DO NOT rsmove this sign.
The following inspections/tests are required to be witnessed by the F re Department Planning
Division staff:
(a) Overhead Rough and Hydro static test: All piping shall be visible and
pumped at normal operating pressure.
(b) Final inspection.
The Fire Department job card, approved plans and conditions letter must be at the job site or
NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire
Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection
date. .
All questions regarding the meaning of these conditions should be re -erred to the Fire
Department Planning & Engineering staff at (760) 863-8886.
Applicant/installer shall be responsible to contact the Fire Department to schu e inspection.
J'
t
t�
Sincerely,
r
Jas DhStubble
Fire Safety Specialist
$lectronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/25/2013
Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 1/25/2)13
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
New Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Add itior/Alteration
Date
1/25/2013
Project Address
53-732 Via Pisa, The Hideaway La Quint
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,132
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures --If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features --If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity Features see Part 9: of 5 Status
Roof Wood Framed Attic R-38 5,132 Radiant Ba a 4 1New
Wall Wood Framed New
Slab Unheated Slab -on- ra2 Perim = 482' New
Door Opaque Door BUILDING & 24 New
-133 M 2 2 X013
COM1 I�Jnv
OA41,2,;�nv
FENESTRATION Exterior
Orientation Area Factor SHGC Overhang Sidefins Shades Status
Left (N) 195.0 0.390 0.32 none none Bug Screen New
Rear (E) , 176.0 0.3907, - D.32nonew none )---,,-Bug Screen a _. New
Rear (SE) 36.0 0.390 0.32 none' 6 none 'Bug Screen -. New
Right (S) _,,1254.8 IJ 10.390 0.32 none ,'n`one Bug Screen `, New
Right is) 17 16.0 /r k 0.550 0!39 none `I none -Bug Screen -, -t . ? ` eNew
Front (W),.,' ' 430.0f ` '0.390_�e 6.32 `•-none' none.,, ._ Bug Screen' - +*�'J�%1(°New
Rear (E) 160.0 0.390 0.32 2.0 none Bug Screen
New
Rear (E) 205.0 0.390 0.32 15.0 none Bug Screen
New
Right (S) 230.0 0.550 0.39 15.0 none Bug Screen
New
Right (S) 110.0 0.390 0.32 10.0 none Bug Screen
New
Front (w) 18.0 0.390 0.32 15.0 none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
• 1 Central Furnace 80% AFUE - Split Air Conditioner 15.0 SEER Setback
New
1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback
New
2 - Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback
New
HVAC DISTRIBUTION Duct
Location Heating Cooling • Duct Location R -Value Status
HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8..0
New
HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented so
New
HVAC 3 & 4 Ducted Ducted Attic, Ceiling Ins, vented 80
New
WATER HEATING
Ot . Type Gallons Min. Eff Distribution, Status
2 Small Gas 75 0.65 All Pipes Ins
New
EnergyPro 5.1 by Ener Soft User Number. 6712 RunCode: 2013-01-25710:36:16 ID:
Pae 1 of 9
aeg: 213-N0005469A-000000000-0000 Registration Date/Time: 2013/01/25 13:39:14 HERS Prodder: Ca10ERTS, Inc
Nil
Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/25/2013
.Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 1/25/2013
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
New Residence
Building Type m Single Family 0 Addition Alone
0 Multi Family O Existing+ Addition/Alteration
Date
1/25/2013
Project Address
53-732 Via Pisa, The Hideaway La Quint
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,132
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity Features see Part 2 of 5 Status
FENESTRATION U- Exterior
Orientation Area Factor SHGC Overhang Sidefins Shades Status
Front (w) 80.0 0.950 0.49 2.0 none Bug Screen New
Front (VIO 120.0 0...3r90:�:-0.32.--..10:0-1 none ,per--_•-- Bug Screen New
`fes
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-01-25710:36:16 ID.'
Page 2 of 9
Reg: 213-N0005469A-000000000-0000 Registration Date/Time: 2013/01/25 13:39:14 HERS Provider: CalCERTS, Inc
Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 1/25/2013
Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 1/25/2M13
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
New Residence
Building Type ®Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Add itio.-i/Alteratio n
Date
1/25/2013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The erforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 4C sf and each zone must have a
se arate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential A endix RA3.3 must be met.
H GH MASS Design - Verify Thermal Mass: 788.0 ft2 Covered Slab Floor, 3.500" thick at Zone 1 Master Suite
HIGH MASS Design - Verify Thermal Mass: 422.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 1 Master Suite
HIGH MASS Design - Verify Thermal Mass: 332.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 4-01fice
HIGH MASS Design - Verify Thermal Mass: 63.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 4 -Office
The HVAC System HVAC 2 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements inResidential Appendix RA3.3 must be met.
HIGH MASS Design - Verify Thermal Mass: 371.0 ft2 Covered Slab Floor, 3.500" thick at Guest Suite
HIGH MASS Design - Verify Thermal Mass: 72.0 112 Exposed Slab Floor, 3.500" thick at Guest Suite
The HVAC System HVAC 3 & 4 must serve only Living Areas. The non -closable area between zones cannot exceed 4G sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HIGH MASS Design - Verify Thermal Mass: 182.0 ft2 Covered Slab Floor, 3.500" thick at Living Zone
HIGH MASS Design - Verify Thermal Mass: 2,526.0 ft2 Exposed Slab Floor, 3.500" thick at Living Zone
HIGH MASS Design= Verify Thermal Mass: 316.0 112 Covered Slab Floor,' 3.500" thick at Bedroom 3
HIGH MASS Design - Verify Thermal Mass: 60.0 R2 Exposed Slab Floor, 3.500" thick at Bedroom 3
HERS REQUIRED VERIFICATION //j jjJ J
.n� ( .. , -.-r.
Items in thisk*sectionT require fi.eld testig-and/o.wr verification by a certified HERS Rater:"The rnsp:4'3ctor must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The Cooling System Carrier 24ANB660/58CVX110 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation
of the correct Condenser.
The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is ;equired to verify that duct
leakage meets the specified criteria.
The Cooling System Carrier 24ANS624158CVX070 includes credit for a 13.0 EER Condenser. A certified HERS rater r ust field verify the installation
of the correct Condenser.
The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is : equired to verify that duct
leakage meets the specified criteria.
The Cooling System Carrier 24ANS660/58CVX110 includes credit for a 12.5 EER Condenser A certified HERS rater rust field verify the installation
of the correct Condenser.
The HVAC System HVAC 3 & 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 3 & 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
Ener,gyPro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-01-25710:36:16 ID: Page 3 of 9
Reg: 213-N0005469A-000000000-0000 Registration Date/Time: 2013/01/25 13:39:14 HERS Provider: CalCERTS, Inc
Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/25/2013
Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 1/25/2013
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
New Residence
Building Type ® Single Family ❑ Addition Alone
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1/25/2013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The Roof R-38 Roof(R.38.2x 14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in
Residential Appendix RA4.2.2.
HERS REQUIRED VERIFICATION _ 0r, 7,.
Items intfiis section require field testing andlor verification by a certified'HERS Rater: The Inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
Ener.QvPro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-01-25710:36:16 ID: Page 4 of 9
Peg: 213-N0005469A-000000000-0000 Registration Date/Time: 2013/01/25 13:39:14 HERS Provider: CalCERTS, Inc
Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 1/25/2013
Electronically Signed at CalCERTS-com by David W Helton (Helton, Deford & Associates) 1/25/2013
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
New Residence
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
1/25/2013
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 4.80 5.02 -0.22
Space Cooling 55.56 50.06 5.49
Fans 11.07 15.00 -3.93
Domestic Hot Water 7.11 7.65 -0.54
Pumps 0.00 0.00 0.00
Totals 78.53 77.74 0.79
Percent Better Than Standard: 1.0%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (w) 270 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (w) 1,338 248
Fuel Available at Site: Natural Gas (N) 1,895 195
Raised Floor Area: 0 (E) 1,338 577
Slab on Grade Area: 5,132 (S) 1,664 601
Average Ceiling Height: 12.1 Roof 5,132 0
Fenestration Average U -Factor: 0.44 TOTAL: 1.621
Average SHGC: 0.34 Fenestration/CFA Ratio: 31.6%
REMARKS-
S
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Scott Design and Title 24, Inc,
1/25/2013
Address 77-085 Michigan Drive Name Tim Scott
Ci /State/Zi Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Helton, DeFord & Associates
Address 1261 N. Big Spring Street Name Jim Deford
City/State/Zip Anaheim, Ca 92807 Phone (909) 957-4550 Signed License # Date
EnerqvPro 5.1 by Ene Soft User Number: 6712 RunCode: 2013-01-25710:36:16 ID: Page 5 of 9
Reg: 213-N0005469A-000000000-0000 Registration Date/Time: 2013/01/25 13:39:14 HERS Provider: Ca10ERTS, Inc
Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/25/2013
Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 1/25/2013
r1
CERTIFICATE OF COMPLIANCE: Residential
Part 4 of 5) CF -1 R
Project Name
New Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1/25/2013
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
1,210
0.026 R-38
270
0 New 4.2.1-A9
Zone 1 Master Suite
Wall
'283
0.069 R-21
0
90 New 4.3.1-A6
Zone 1 Master Suite
Wall
238
0.069 R-21
90
90 New 4.3.1-A6
Zone 1 Master Suite
Wall
14
0.069 R-21
135
90 New 4.3.1-A6
Zone 1 Master Suite
Wall
276
0.069 R-21
180
90 New 4.3.1-A6
Zone 1 Master Suite
Wall
45
0.069 R-21
270
90 New 4.3.1-A6
Zone 1 Master Suite
Slab
788
0.730 None
0
180 New 4.4.7-A 1
Zone 1 Master Suite
Slab
422
0.730 None
0
180 New 4.4.7-A 1
Zone 1 Master Suite
Roof
395
0.026 R-38
270
0 New 4.2.1-A9
Bdrm 4 -Office
Wall
108
0.069 R-21
0
90 New 4.3.1-A6
Bdrm 4 -Office
Wall
241
0.069 R-21
180
90 New 4.3.1-A6
Bdrm 4 -Office
Wall
25
0.069 R-21
270
90 New 4.3.1-A6
Bdrm 4 -Office
Slab
332
0.730 None
0
180 New 4.4.7-A1
Bdrm 4 -Office
Slab
63
0.730 None
0
180 New 4.4.7-A1
Bdrm 4 -Office
Roof
443
0.026 R-38
270
0 New 4.2.1-A9
Guest Suite
Wall
271
0.069 R-21
0
90 New 4.3.1-A6
Guest Suite
FENESTRATION SURFACE DETAILS
ID
Type
Area LI -Factor SH C2
Azm Status
Glazing Type
Location/Comments
1
Window
24.0 0.390 NFRC 0.32 NFRC 0 New
Double Non -Metal Tinted
Zone 1 Master Suite
2
Window
120.0 0.390 NFRC 0.32 NFRC 90 New
Double Non -Metal Tinted
Zone 1 Master Suite
3
Window -
'56.0 0.390 NFRC 0.32 NFRC 90 New
Double Non -Metal Tinted
Zone 1 Master Suite
4
Window
36.0 0.390 NFRC 0.32 NFRC 135 New
Double Non -Metal Tinted
Zone 1 Master Suite
5
Window__. ,_... 56.0 0.390 NFRC _ -0.32 NFRC___ _._-_..180 New_-
Double Non -Metal_ Tinted..,-,-.
Zone 1 Master Suite
6
Window
N 32.0 0.390 NFRC 0.32 NFRC 180 New NJ Double Non -Metal Tinted'
1 Zone 1 Master Suite
7
Window
'20.0 0.390 NFRC ! 0.32 NFRC 180 New
Double Non -Metal Tinted
' Zone 1 Master Suite
8
Window
6.Q =x;0.550 NFRC 0.39 NFRC „-4 180 New -'F Pocket Doors r
Zone 1 Master Suite
9
Window
6.0 0.390 NFRC 0.32 NFRC k 0 New
Double Non -Metal Tinted +
Bonn 4 -Office it%
10
Window )36.0 r 0.390 NFRC 0.32 NFRC 40 New . s
Double Non -Metal Tinted 1
Bdrm 4-Office'i
11
IwindowX r
L-13.8 _0.390 NFRC X0.32 NFRC "180 New
Double Non-Metal.Tintede'
BdrM 4 -Office -1-00
12
Window
13.8 0.390 NFRC 0.32 NFRC 180 New
Double Non -Metal Tinted
Bdrm 4 -Office
13
Window
76.0 0.390 NFRC 0.32 NFRC 180 New
Double Non -Metal Tinted
Bdrm 4 -Office
14 Window
9.0 0.390 NFRC 0.32 NFRC 0 New
Double Non -Metal Tinted
Guest Suite
15
Window
24.0 0.390 NFRC 0.32 NFRC 0 New
Double Non -Metal Tinted
Guest Suite
16
Window
6.0 0.390 1 NFRC 0.32 NFRC 0 New
Double Non -Metal Tinted
Guest Suite
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116•B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC HqA Wd
Ove hanq Left Fin
Len H t LExt RExt Dist Len
Ri ht in
H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
JBug Screen
0.76
16
JBug Screen
0.76
EnergyPro
5.1 by Ener Soft User Number: 6712
RunCode: 2013-01-25710:36:16 ID:
Pa e 6 of 9
Reg: 213-N0005469A-000000000-0000 Registration Date/Time: 2013/01/25 13:39:14 HERS Provider: CalCERTS, Inc
Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 1/25/2013
Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 1/25/2013
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
New Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1112512013
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation
Factor Cavity Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Wall
95
0.069 R-21
90
90 New 4.3.1-A6
Guest Suite
Wall
276
0.069 R-21
180
90 New 4.3.1-A6
Guest Suite
Wall
190
0.069 R-21
270
90 New 4.3.1-A6
Guest Suite
Slab
371
0.730 None
0
180 New 4.4.7-A1
Guest Suite
Slab
72
0.730 None
0
180 New 4.4.7-A1
Guest Suite
Roof
2, 708
0.026 R-38
270
0 New 4.2.1-A9
Zone 3 Great/Game/Kitch
will
874
0.069 R-21
0
90 New 4.3.1-A6
Zone 3 Great/Geme/Kitch
Door
24
0.500 None
0
90 New 4.5.1-A4
Zone 3 Great/Game/Kitch
Wall
279
0.069 R-21
90
90 New 4.3.1-A8
Zone 3 Great/Game/Kitch
Wall
89
0.068 R-21
180
90 New 4.3.1-A6
Zone 3 Great/Game/Kitch
Wall
700
0.069 R-21
270
90 New 4.3.1-A6
Zone 3 Great/Game/Kitch
Slab
182
0.730 None
0
180 New 4.4.7-A1
Zone 3 Great/Game/Kitch
Slab
2,526
0.730 None
0
180 New 4.4.7-A1
Zone 3 Great/Game/Kitch
Roof
376
0.026 R-38
270
0 New 4.2.1-A9
Bdrm 3
Wall
140
0.069 R-21
D
90 New 4.3.1-A6
Bdrm 3
Wall
1 1351
0.069 R-21
90
90 New 14.3.1-A6
JBdrm 3
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC
Azm Status Glazing Type
Location/Comments
17
Window
6.0 0.390 NFRC
0.32 NFRC 180 New
Double Non -Metal Tinted
Guest Suite
18
Window
13.8 0.390 NFRC
0.32 NFRC 180 New
Double Non -Metal Tinted
Guest Suite
19
Window
13.8 0.390 NFRC
0.32 NFRC 180 New
Double Non -Metal Tinted
Guest Suite
20
Window
30.0 0.390 NFRC
0.32 NFRC 270 New
Double Non -Metal Tinted
Guest Suite
21
Window. _.,,, 32.0 0.390 NFRC _
„0.32 NFRC_.. _ --,0 New
_.._ ., Double.. Non -Metal Tinted. ,._.. ,
Zone 3 Great/Game/Kitchen/N
22
Window'
\32.0 0.390 NFRC 0.32 NFRC 1,0 New '_
Double Non -Metal Tinted
i Zone 3 Great/Game/Kitchen/A/
23
Window
7.0 0.390 NFRC t
0.32 'NFRC 0 New
Double Non -Metal Tinted
' Zone 3 Great/Game/Kitchen%N
24
Window
7.0,---0.390 NFRC
0.32 NFRC sT 0 New
4e- Double Non -Metal Tinted
Zone 3 Great/Game/Kitchen/N
25
Window
420 10.390 NFRC
0.32 NFRC N 0 New
Double Non -Metal Tinted 4
- Zone 3 Great/Game/Kitchen/N
26
Window �f ,r 4.0 i 0.390 NFRC
0.32 NFRC 0 0 New
A Double Non -Metal Tinted i
Zone 3 GreaUGame/Kitchen/N
27
WindowA r ',,_4.01-0.390 NFRC
-0.32 NFRC 0 New
N, Double Non -Metal -Tinted
_ Zone 3 Great/Game/Kitchen/N
28
window
160.01 0.390 NFRC
0.32 NFRC 90 New
Double Non -Metal Tinted
Zone 3 Great/Game/Kitchen/N
29
Window
205.0 0.390 NFRC
0.32 NFRC 90 New
Double Non -Metal Tinted
Zone 3 Great/Game/Kitchen/N
30
Window
230.0 0.550 NFRC
0.39 NFRC 180 New
Patio Doors
Zone 3 Great/GamilKitchen/N
31
Window
110.0 0.390 NFRC
0.32 NFRC 180 New
Double Non -Metal Tinted
Zone 3 Great/Game/Kitchen/N
32
Window
18.0 0.390 NFRC
0.32 NFRC 270 New
Double Non -Metal Tinted
Zone 3 Great/Game/Kitchen/N
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hang Left Fin
Len H t LExt RExt Dist Len
Right Fin
Hot Dist Len H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
10.0 16.0 2.0 0.1
2.0 2.0
29
Bug Screen
0.76
10.0 20.4 15.0 0.1
15.0 15.0
30
-Bug Screen
0.76
10.0 23.0 15.0 0.1
15.01 15.0
31
JBug Screen
0.76
10.0 11.0 10.0 0.1
10.0 10.0
32
IBug Screen
1 0.761
10.01 18.5 15.0 0.1
15.0 15.0
EnergyPro
5.1 by EnerqySoft User Number: 6712
RunCode: 2013-01-25710:36:16 ID:
Page 7 of 9
Reg: 213-N0005469A-000000000-0000 Registration Date/Time: 2013/01/25 13:39:14 HERS Provider: CalCERTS, Inc
Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/25/2013
Electronically Signed at CalCERTS.com by David W Helton (Helton, Deford & Associates) 1/25/2013
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
New Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1112512013
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
wall
186 0.069 R-21
180 90 New 4.3.1-A6 Bdrm 3
wall
130 0.069 R-21
270 90 New 4.3.1-A6 Bdrm 3
Slab
316 0.730 None
0 180 New 4.4.7-A1 Bdrm 3
Slab
60 0.730 None
0 180 New 4.4.7-A1 Bdrm 3
FENESTRATION SURFACE DETAILS
ID
Type Area U -Factor SHGC
Azm Status Glazin Type Location/Comments
33
window 20.0 0.950 1 NFRC 0.49 1 NFRC 270 New Entry Door Zone 3 GreaUGame/Kitchen/N
34
Window 40.0 0.950 NFRC 0.49 NFRC 270 New Entry Door Zone 3 Great/GameXitchen/N
35
Window '20.0 0.950 NFRC 0.49 NFRC 270 New Entry Door Zone 3 Great/GameXitchen/N
36
Window 120.0 0.390 NFRC 0.32 NFRC 270 New Double Non -Metal Tinted Zone 3 Great/Game/Kitchen/N
37
Window- ,„ 48.0 0.390 NFRC 0.32 .NFRC_._:.._.._ 180 New.-.,-,,. Doub/e_Non,Metal:Tinted_., Bdrm 3
38
Window 124.0 0.390 NFRC w' - 0.32 NFRC 180 New Double Non -Metal Tinted 1 Bdrm 3
39
Window 3.8 0.390 NFRC f 0.32 'NFRC 180 New Double Non -Metal Tinted Bdrm 3
40
Window 3.6 :.:0.390, NFRC 0.32 NFRC -4180 New - Double Non -Metal Tinted Bdrm 3
l- it I (
1 .t' !' A I F1
(1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC H t Wd
Ove hang Left Fin Right Fin
Len I H t LExt RExt Dist Len Hat Dist Len Hat
33
Bug Screen 0.76 10.0 2.0 2.0 0.1 2.0 2.0
34
Bug Screen 0.76 10.0 4.0 2.0 0.1 2.0 2.0
35
Bug Screen 0.76 10.0 2.0 2.0 0.1 2.0 2.0
36
Bug Screen 0.76 10.0 12.0 10.0 0.1 10.0 10.0
37
Bug Screen 0.76
38
Bug Screen 0.76
39
Bug Screen 0.76
40
Bug Screen 0.76
EnergyPro
5.1 by EnergySoft User Number.- 6712
RunCode: 2013-01-25T10:36:16 ID: Page 8 of 9
Reg: 213-N0005469A-000000000-0000 Registration Date/Time: 2013/01/25 13:39:14 HERS Provider: Ca10ERTS, Inc
Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 1/25/2013
Electronically Signed at Ca10ERTS.com by David W Helton (Helton, Deford & Associates) 1/25/2-313
1
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5) CF -1 R
Project Name
New Residence
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1112512013
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area ft
New Existing Altered Removed Volume Year Built
HVAC 1 Zone 1 Master Suite
1,210 14,278
Bedroom 4 -Office
395 3,832
HVAC 2 Guest Suite
443 4,430
HVAC 3 & 4 Living Zone
2,708 35,746
Bedroom 3
376 1 3,760
Totals 1 5,1321 0 0 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC 1 1 Central Furnace
80% AFUE Split Air Conditioner 15.0 SEER Setbacr New
HVAC 2 1 Central Furnace
80% AFUE Split Air Conditioner 16.0 SEER Setbacr New
HVAC 3 & 4---'� 2 . _ Central,Furnace
80Y AFUE Split Air Conditioner:= '15.0 SEER Setbacr New
-.4
HVAC DISTRIBUTION ## l ., 1 f 1
1
-. ✓ �- �� -- ,;
System Name Heating
_� ... - ,'~ "Duct=;' 't! Ducts7L
Cooling Duct Location R -Value Tested? Status
HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New
HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 IzI New
HVAC 3 & 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 El New
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
StEndby
Loss or
Filot
Ext.
Tank
Insul. R-
Value
Status
Bradford -White 75 Gal
2
Small Gas
All Pipes Ins
65,000
75
0.65
;2/a
n/a .
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
N
c
0
i�
a —
System Name
Pipe
Lencith
Pipe
Diameter
Insul.
Thick.
aty. HP
Plenum Outside Buried
Ener Pro 5.1 by Ener Soft User Number: 6712
RunCode: 2013-01-25T10:36:16 ID: Page 9 of 9
Reg: 213-N0005469A-000000000-0000 Registration Date/Time: 2013/01/25 13:39:14 HERS Provider: CalCERTS, Inc
Sladden Engineering
45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847
6782 Stanton Avenue, Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369
450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863
800 E. Florida Avenue, Hemet, CA 92543 (951) 766-8777 Fax (951) 766-8778
February 1, 2013
0
Sun Vista Development Corporation
P.O. Box 1144
La Quinta, California 92247
Project: Proposed Custom Residence
53-732 Via Pisa
The Hideaway
La Quinta, California
Subject: Geotechnical Update
Project No. 544-13028
13-02-042
VED
APR 22 2013
CI
Co N OFLA
MMUN��UrNTA
E
Opmevr
Ref: Geotechnical Engineering Report prepared by Earth Systems Southwest (ESSW) dated
September 22, 2000; File No. 07117-10, Report No. 00-09-772
Report of Testing and Observation During Rough Grading prepared by ESS dated
August 28, 2002; File No. 07117-11, Report No. 01-07-718
Report of Testing and Observation During Rough Grading prepared by Sladden
Engineering dated October 12, 2003; Project No. 544-2199 Report No: 03-10-647
As requested, we have reviewed the above referenced geotechnical reports as they relate to the
design and construction of the proposed custom residence. The project site is located at 53-732
Via Pisa within the Hideaway Golf Club development in the City of La Quinta, California. It is
our understanding that the proposed residence will be a relatively lightweight wood -frame
structure supported by conventional shallow spread footings and concrete slabs on grade.
The subject lot was previously graded during the rough grading of the Hideaway project site and
was subsequently regraded. The rough grading included over -excavation of the native surface
soil along with the placement of engineered fill soil to construct the building pads. The regrading
included processing the surface soil along with minor cuts and fills to construct the individual
building pads to the current configurations. Some additional over -excavation was performed in
areas where the building envelopes were reconfigured. The most recent site grading is
summarized in the referenced Report of Testing and Observations During Rough Grading
prepared by Sladden Engineering along with the compaction test results.
f -
The referenced reports include recommendations pertaining to the construction of residential
structure foundations. Based upon our review of the referenced reports, it is our opinion that the
structural values included in the referenced grading report prepared by Sladden Engineering
remain applicable for the design and construction of eiopo O� e
foundations. L/'1 Q PINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DA 11 1t
February 1, 2013 -2- Project No. 544-13028
13-02-042
Because the lot has been previously rough graded, the remedial grading required at this time
should be minimal provided that the building falls within the previously established building
envelope. The building area should be cleared of surface vegetation, scarified and moisture
conditioned prior to precise grading. The exposed surface should be compacted to a minimum of
90 percent relative compaction is attained prior to fill placement. Any fill material should be
placed in thin lifts at near optimum moisture content and compacted to at least 90 percent
relative compaction.
The allowable bearing pressures recommended in the referenced grading report prepared by
Sladden Engineering remain applicable. Conventional shallow spread footings should be
bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent
grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be
at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing
allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf
for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be
utilized if desired. The maximum allowable bearing pressure should be 3000 psf. The
recommended allowable bearing pressures may be increased by one-third for wind and seismic
loading.
Lateral forces may be resisted by friction along the base of the foundations and passive resistance
along the sides of the footings. A friction coefficient of 0.50 times the normal dead load forces is
recommended for use in design. Passive resistance may be estimated using an equivalent fluid
weight of 300 pcf. If used in combination with the passive resistance, the frictional resistance
should be reduced by one third to 0.33 times the normal dead load forces.
The bearing soil is non -expansive and falls within the "very low" expansion category in
accordance with 2010 California Building Code (CBC) classification criteria. Slab thickness and
reinforcement should be determined by the structural engineer. We recommend a minimum
floor slab thickness of 4.0 inches. All slab reinforcement should be supported on concrete chairs
to ensure that reinforcement is placed at slab mid -height.
Slabs with moisture sensitive surfaces should be underlain with a moisture vapor retarder
consisting of a polyvinyl chloride membrane such as 10 -mil Visqueen, or equivalent. All laps
within the membrane should be sealed and at least 2 inches of clean sand should be placed over
the membrane to promote uniform curing of the concrete. To reduce the potential for punctures,
the membrane should be placed on a pad surface that has been graded smooth without any sharp
protrusions. If a smooth surface can not be achieved by grading, consideration should be given to
placing a 1 -inch thick leveling course of sand across the pad surface prior to placement of the
membrane.
Based on our field observations and understanding of local geologic conditions, the soil profile
type judged applicable to this site is So, generally described as stiff soil. The following presents
additional coefficients and factors relevant to seismic mitigation for new construction based upon
the 2010 California Building Code (CBC).
Sladden Engineering
February 1, 2013 -3- Project No. 54413028
13-02-042
The seismic design category for a structure may be determined in accordance with Section 1613
of the 2010 CBC or ASCE7. According to the 2010 CBC, Site Class D may be used to estimate
design seismic loading for the proposed structures. The 2010 CBC Seismic Design Parameters are
summarized below.
Occupancy Category (Table 1604.5): II
Site Class (Table 1613.5.2): D
Ss (Figure 1613.5.1):1.50g
Sl (Figure 1613.5.1): 0.608
Fa (Table 1613.5.3(1)):1.0
Fv (Table 1613.5.3(2)):1.5
Sms (Equation 16-36 {Fa X Ss)): 1.508
Sm1 (Equation 16-37 {Fv X Si)): 0.90g
SDS (Equation 16-38 {2/3 X Sms)): 1.00g
SDl (Equation 16-39 12/3 X Sm1)): 0.60g
Seismic Design Category: D
In addition, we have sampled the surface soil on the subject lot to determine the soluble sulfate
content as it relates to selecting appropriate concrete mix designs. Testing indicates that the site
soil is generally considered non- corrosive with respect to concrete. The testing indicated soluble
sulfate content of 100 ppm (0.010 percent) that corresponds with the "negligible" exposure
category in accordance with ACI 318-08, Table 3. Based upon this, the use of sulfate resistance
concrete mixes is not required.
If you have questions regarding this letter or the referenced reports, please contact the
undersigned.
Respectfully submitted,
SLADDEN ENGINEERIN
Brett L. Anderson���\// I 1 AN RETT L. '
y /v► N
Principal Engineer No. C45389
Exp. 9130/14
CIVIL
SER/gvm ENGINEERING
r�FOFC
Copies: 4/Sun Vista Development Corp.
Sladden Engineering
LA QUINTA 12-1462
DEC. 28, 2012
5 y`1- ) 3 oz8
1.3-02,- oqz-
Please verify that soils reports contain all of the above information. In addition, to assure
continuity between the investigation/reporting stage and the execution stage, please use
the following checklist to verify that the conclusions and recommendations in the report
cover all the required elements. Only then can we be assured that the construction
documents address all of the site soil conditions.
La Quinta Geotechnical Report Checklist
Does the "Conclusions and Recommendations" section of the report address each of the
following criteria?
"Address" means:
(a) the criterion is considered significant and mitigation measure(s) noted, -or;
(b) the criterion is considered insignificant and explicitly so stated.
Yes No Criterion
❑ Foundation criteria based upon bearing capacity of natural or compacted soil.
❑ Foundation criteria to mitigate the effects of expansive soils.
❑ Foundation criteria based upon bearing capacity. of natural or compacted soil.
❑ Foundation criteria to mitigate the effects of liquefaction.
❑ Foundation criteria- to mitigate the effgcts of seismically induced differential
settlement.
❑ Foundation criteria to mitigate the effects of long-term differential settlement.
❑ Foundation criteria to mitigate the eff. ects of varying soil strength.
❑ Foundation criteria to mitigate expected total and differential settlement.
Any "No" answers to the above checklist should be noted as specific required
corrections.
Sladden Engineering
6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369
45090 Golf Center Pkwy, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847
450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863
Date: February 4, 2013
Account No.: 544-13028
Customer: Sun Vista Development
Location: The Hideaway, 53-732 Via Visa, Lot 290, La Quinta
Sulfate Series
Analytical Report
Soluble Sulfates
per CA 417
PPM
100
Soluble Chloride
per CA 422
PPM
Sulfate 544-13028 020413
TABLE 19-A-2—REQUIREMENTS FOR SPECIAL EXPOSURE CO.NDMONS
TABLE 19-A-3—REQUIREMENTS,FOR CONCRETE
EXPOSED TO SULFATE -CONTAINING Sni,i mnm(z
MINIMUM:rc, .
MAXIMUM
NORMAL' -WEIGHT AND .
Maxlmum'Water-
Cementltlous
Matertals:tRatio,-by'.
We'lght,..;:
Nor ml- elght°
Aggregate
Concretes
WATMCE?AENtmouS
LIGHTWEIGHT.:
WATER- SOLUBLE
SULFATE
(SOi),INSOIL,
PERCENTAGE BY
WEIGHT
MATERIALS` RATIO;'BY.:
AGGREGATECONCRETE,
EXPOSURE CONDITION
WEIGHT,'NORMAL=WEIGHT
AGGREGATE CONCRETE
PsI'..•.
x 0.00689 for MPs
Concrete intended to have low permeability when
•
exposed to water
0-50
0.10-0.20
Concrete exposed to freezing and thawing in a moist
II, IP(MS), IS
(MS)
4,000
condition or to deicing chemicals
Scvcrc
0.20-2.00
1,50040,000
0.45
4,500
For corrosion protection for reinforced concrete
4,500
Very severe
exposed to chlorides from deicing chemicals, salts or
Over 10,000
V plus
pozzolan3
brackish water, or -spray -from thesc'sources
0.40
5,000
TABLE 19-A-3—REQUIREMENTS,FOR CONCRETE
EXPOSED TO SULFATE -CONTAINING Sni,i mnm(z
— - -- - - • _ -u ur nrgner strength may be required for low permeability or forprotection
against corrosion of embedded items or freezing and thawing (Table 19-A-2)-
ZScawater.
3Pozzolan that has been determined by test or service record
tairiing Type V cement. to improve sulfate resistance when used in concrete con -
2_264
NORMAL -WEIGHT
AGGREGATE
LIGHTWEIGHT
AGGREGATE
CONCRETE
Maxlmum'Water-
Cementltlous
Matertals:tRatio,-by'.
We'lght,..;:
Nor ml- elght°
Aggregate
Concretes
V "'Normal-
W.Ight and
Lightwilght'
-Aggregate..
Concrete,., psis
SULFATE
EXPOSURE
WATER- SOLUBLE
SULFATE
(SOi),INSOIL,
PERCENTAGE BY
WEIGHT
SULFATE (SO4) IN
WATER, ppm
•.
CEMENT TYPE
x 0.00689'for MPe.
Negligible
0.00-0.10
0-150
Modcrate2.
0.10-0.20
I50-1,500
II, IP(MS), IS
(MS)
'0.50•
4,000
Scvcrc
0.20-2.00
1,50040,000
V
0.45
4,500
Very severe
Over 2.00
Over 10,000
V plus
pozzolan3
0.45
4,500
— - -- - - • _ -u ur nrgner strength may be required for low permeability or forprotection
against corrosion of embedded items or freezing and thawing (Table 19-A-2)-
ZScawater.
3Pozzolan that has been determined by test or service record
tairiing Type V cement. to improve sulfate resistance when used in concrete con -
2_264
Summit Structural Engineering
April 18, 2013
BMC/Boulders West Components/Indio Truss
45-491 Golf Center Parkway
Indio, CA 92201
Attn: Ignacio Vargas
Subject: Roof Truss Shop Drawings and Calculations
Hideaway, Lot 290
53-732 Via Piza
La Quinta, CA
Dear Truss Designer,
PO BOX 2618
902 Baycolt Way
McCall, ID 83638
(208) 634-8148
Fax (208) 634-6395
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
(3" vi--�
The roof truss drawings by BMC for the subject project were received by our office on
April 17, 2013, and is approved. The submittal has been reviewed for general
conformance to the design concept of the project structural plans. The fabrication
processes, techniques of construction, dimensions, and quantities are not a part of this
review. Since the shop drawings were reviewed only for general conformance with the
structural plans, unless variations from the structural plans have been clearly indicated,
we may not have listed them. Our review of these drawings does not relieve the truss
engineer and the framing contractor from complying with the structural plans.
Yours truly,
SUMMIT STRUCTURAL ENGINEERING
Benjamin Herbst, P.E.
BH
cA2012jobfi1es\SV-424\424_truss l .doc
0ROFESSI
t\ N
� s�
No. C054193
Exp. 1231 1
sl CIVI\.
\CF CA\
Residential, Commercial, Industrial, Land Development