Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
04-7917 (SFD)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T4ht 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 04-.000_0-7-917 Property Address: i�5r3�74�9,VrBA�P1I+SA� APN: 772-530-0 - - Application description: DWEL G NGLE FAMILY DETACHED Property Zoning: L- ENS SIDENTIAL 1lppliootion voluation:J 007 Applicant: O r\ Ar itect or Engineer: Lic. No.: OOR SQUARE FOOT LICENSED CONTBABWOR'S DECLARATION I hereby affirm under penalty of perjury that I am ' under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Busine d Pro es i s Code, and my License is in full force and effect. License Cla : B license No.: 799449 Dat' , 6J: _Co actor. — - _ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he, or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not -apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractorls) licensed pursuant to the Contractors' State License Law.). 1 _ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: FRANA 58-749 VIA PISA LA QUINTA, CA 92253- Contractor: 2253 Contractor: JACOBS HOMES INC, PETER P.O. BOX 692 LA QUINTA, CA 92247 (760)777-9921 Lic. No.: 799449 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 6/09/05 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm. under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided - for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier HRH INSUR Policy Number 176983305 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to beccT ct to the workers' compensation laws of California, and agree that, if I should be c orkers' compensation provisions of Section 3700 of the Labor C shall forth ' omply with those provisions. Date � 1 Ap _ant:,! WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made; each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or anon of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the ve inf ion is correct. I agree to comply with all city and county ordinances and state laws relating to i din str tion, and h�eby authorize representatives of this counto/ter upon the above-mentione roperty ,pfor coon purpo 3 Signature IAPPlicant-or- — - Application Number . . . . . 04-00007917 Permit . . . BUILDING PERMIT . Additional desc . . Permit Fee . . . . 1553.00 Plan Check Fee 1009.45 Issue Date . . . . Valuation . . . . 360807 Expiration Date 12/06/05 Qty Unit Charge Per Extension BASE FEE 639.50 261.00 3.5000 ------------------------------------------------------------------------------ THOU BLDG 100,001-500,000 913.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . . Permit Fee . . . . 159.10 Plan Check Fee 39.78 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/06/05 Qty Unit Charge Per Extension BASE FEE 15.00 4117.00 .0350 ---------------------------------------------------------------------------- ELEC NEW RES - 1 OR 2 FAMILY 144.10 Permit . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/06/05 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . . Permit Fee . . . . 132.50 Plan Check Fee 33.13 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/06/05 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36.00 4.00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 6.00 6.5000 EA MECH VENT FAN 39.00 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 Permit . . . . . . PLUMBING LQPERMIT Application Number . . . . . 04-00007917 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 218.25 Plan Check Fee 54.56 Issue Date . . . . Valuation . . . . 0 Expiration Date 12/06/05 Qty Unit Charge Per Extension BASE FEE 15.00 23.00 6.0000 EA PLB FIXTURE 138.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 DA PLD WATER IIEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 11.00 .7500 EA PLB GAS PIPE >=5 8.25 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 4117 SQ. FT. SFD THIS PERMIT DOES NOT INCLUDE POOL BLOCK WALLS OR DRIVEWAY APPROACH.AND EXT. FIREPLACE. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 402.01 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 100.95 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 36.08 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Paid Credited ------------------------------------- Due Permit Fee Total -------------------- 2077.85 .00 .00 2077.85 Plan Check Total 1136.92 500.00 .00 636.92 Other Fee Total 2944.04 .00 .00 2944.04 Grand Total 6158.81 500.00 .00 5658.81 LQPERMIT w F'4►' v P.O. BOX 1504 rBuilding �] ' i 78-495 CALLE TAMPICO Addressv(r� I v f4 �s�r LA OUINTA, CALIFORNIA 92253 Owner ��" li f y ) 'a q BUILDING: TYPE CONST. bl mailing Address City lZip ITO. V (✓s'C"Afi /r7�/1v� '704e f"0- uJS(o City Zip Tel. Lu 1),,,,.A -4 /;YO /7/ & Classif. Lic. # Arch., Engr.,� Designer Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Cod(a: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT z ° ` ell /;�> APPLICATION ONLY OCC. GRP. A.P. Number / Legal Description Li 2�L ' T Z 4-eW_ 2 - Project Project Description 1YI12 -f Sq. Ft. (J/, NO. %/ No. Dw. Size / Stories Units New Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. ilt'1� Infrastructure 20 my TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from, Property Line FINAL DATE INSPECTOR Issued by:_ Validated by: Validation: YELLOW = APPLICANT Date Permit PINK = FINANCE Coachella Valley Unified *School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 E This Box For District Use Only DEVELOPER FEES PAID AREA: WOUNT ' LEVEL ONE AMOUNT: LEVELTWOAMOUNT: AITIGATION AMOUNT: COMMAND. AMOUNT: nATF.• RF.r..F.IPT- 'HF.r'K N- INITIAI .C• CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Residence is at The Hideaway Date J u .l, 244LIs- Owner's Name: Frana Phone No. Project Address: 53-749 Via Pisa La Quinta, CA Project Description: 1 SFD APN: 772-530-051 Tract #: Lot #'s: Type of Development: Residential XX! Commercial Industrial Total Square Feet of Building Area: 4,117 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is corre:t and makes this statement under penalty of perjury and further represents that he/she is authorized to sj o alf of the owner/developer. Dated: 4� — /— <J S �--ti•�� SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Note: Number of Sq.Ft. 4,117 Amount per Sq -Ft. $ 2.88 Amount Collected $ 11,856.96 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services R Certificate issued by: Elvira Mattson, Office Technician Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as Ierein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts an the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. ti�':eamLdoeside� Ice icertilicate of compliance tvrm Bibles PO I.ISE .doe 1/16/03 T Dec 16 04 10:35a gary & jackie frana 760-771-9457 p.t I:IDEL n',',' Nif ZONAL TITLE 'Af07Dl V iSION 1NzPARTMFNT WHEN RECORDED MAIL TO: Jacqueline R. Frana 79775 Tangelo La Quinta, Ca 92253 MAIL TAX STATEMENT TO: SAME AS ABOVE DOC a 2003-047031 01/22/2003 ea:OoA Fea:39.00 Pape t of b Doc T Tax Paid Recorded In Official Records County of Riverside Cary L. Orso Assessor, County Clerk 8 Recorder 1111111111111 pill M I11111111 Eserow(6 6510-BAM w s u. Pee WE w -core MOC4M ss DOCUMENT TRANSFER TAX S 584.10 A R L COPY -0N6 11EIiJFC nC+G OfFM XX Computed on the consideration or value of property conveyed; OR 33 Computed on the consideration or value less liens or encumbrances remaining at the time of sale. THE UNDERSIGNED Signature of Declarant or Agent determining tax - Firm Name r---o.�o-o�� GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowlecged, ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company ("Grantor"), hereby GRANT(S) to Jacqueline R. Frana, a marred woman ase ** ("Grantee"), file real property located in the City of La Quinta, County of Riverside, State of California, described as: �* sole and separate property See Legal Description attached hereto and incorporated herein as Exhibit "A". SUBJECT TO all matters of record including, without limitation, the covenants and agreements described in Exhibit "A" attached hereto. Dated: January 13, 2003 1 "LA/627969.1 ND LA QUINTA PARTNERS, LLL, a Delaware limited liability Company By: Nationwide Realty Investors, Ltd., an Ohio limited liability company its managing member 4Wm"+-E4" 6o L C.t ern President-afid Chief Dec 16 04 10:35a gary & jackie frana 760-771-9457 p.2 STATE OF _ ) ss. COUNTY OF On 2882; before me the undersigned, a notary public in and for said State, personally appeared 3es� . ac e cx � or proved to me on the basis of satisfactory evidence) o be the person(s) whose name(scf4re subscribed to the within instrument and acknowledged to me tha&she/they execute the same s/ er/their authorized capacity(ies), and that byk@!Yher/their signature(s) on the instrument thele-rson(s), or the entity upon behalf of which the person(s) acted, executed the instr=ent. IIIT HE 1111111 IN I 111111111111111111111111111 •���ao. 1 •LA/6Y7969.1 2 Dec 16 04 10:35a gary 8 jackie frana 760-771-9457 p.3 EXHIBIT "A" Legal Description Parcel No. 1: Lot 286 (the "Lot") of Amended Tract No. 29894-2 as shown on a Subdivision Map (the "Map") recorded on December 12, 2002 , in Book 327 , Pages 56 to 88 , inclusive, of Ylaps, in the Office of the Riverside County Recorder. EXCEPTING AND RESERVING THEREFROM TO GRANTOR, and its successors, assigns, invitees, licensees and employees, together with the right to grant and transfer all or a portion of the same, all easements and rights for access, ingress, egress, encroachment, maintenance, drainage, support, and for other purposes over the Association Maintenance Areas and other portion of the Lot, reserved to Grantor in the following instruments: 1. The Amended and Restated Declaration of Covenants, Conditions and Restrictions and Reservation of Easements for The Hideaway Owners Association (as amended or supplemented, the "Declaration"), recorded onDecember 13 , 2002, as Instrument No. 2002-745939 of Official Records of Riverside County, California (the "Official Records" ); FURTHER RESERVING THEREFROM, the right to enter the Lot for a term of twelve (12) months following the recordation of this Grant Deed, to complete and repair any improvements or landscaping located thereon as determined necessary by Grantor, in its sole discretion, in order to comply with requirements for the recordation of the Final Tract Map, the. grading of said Tract and/or in compliance with the requirements of applicable governmBntal agencies. Such entry by Grantor shall be preceded by reasonable notice to Grantee W6. -e such entry. If this reservation of right of entry is not complied with by Grantee, Grantor may enforce this right of entry in a court of law. Grantee shall be responsible for all damages arising out of said breach including attorneys' fees and court costs. This reservation of right of entry shall automatically expire twelve (12) months from the recordation of this Grant Deed. Parcel No. 2: Nonexclusive easements for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as described in the Declaration. SUBJECT TO: Nondelinquent general, special and supplemental real property taxes and assessments. — 1111111111 pII�IIB�Inlllllllll�l•�±!•�i='—• I-LAl677969.1 Dec 16 04 10:35a gary & jackie frana 760-771-9457 p.4 2. All other covenants, conditions, restrictions, reservations, easements, rights and rights-of-way of record including, without limitation, the Declaration and the Map for Tract No. 29894-2 Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in this Grant Deed, (b) grants to Grantor and The Hideaway Owners Association such powers and rights as are set forth in the Declaration ,and (c) accepts, covenants and agrees to be bound by and assume performance of all of the applicable provisions and requirements set forth in the Declaration, including Section 13.15establishi.ng the procedure for resolving disputes with Grantor, and the notice, which provisions and requirements are acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be performed by Grantee under the Declaration. The restrictions on use and occupancy of the Lot are set forth in the Declaration to which this Grant Deed is specifically and expressly made subject. GRANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING, granting unto Grantor and The Hideaway Owners Association such powers and rights which are set forth in the Declaration defined above, on / ao - 0 3 , 200't. j Ja c ne R. Frana STATE OF \ c c�, � C ) 1 ss. COUNTY ) On V - p3 , , before me, the undersi ned, a notary public in and for said State, personally appeared c . .kz(or proved to me on the basis of satisfactory evidence) to be the persons) whose name(s)PIPre subscribed to the within instrument and acknowledged tope that heA&they executed -the same in his�eir authorized capacity(ies), and that by hi er/t eir signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS MY OFFICIAL SEAL Signature IN• /Z211:903 W! I-LAf627%9.1 4 Dec 16 04 10:35a gary & jackie frana GOVERNTMENT CODE 27361.7 760-771-9457 p.5 I CERTIFY UNDER PENALTY OF PERJURY THAT THE NOTARY SEAL ON THE DOCUMENT TO WHICH THIS IS ATTACHED READS AS FOLLOWS. NAME OF NOTARY: COMMISSION NUMBER: DATE COMMISSION EXPIRES PLACE OF EXECUTION: DATE: �- -/ )�f / FIDELITY NATIONAL TITLE BUILDER SERVICES CATHERINE A- HAMMONS 1258348 APRIL 15, 2004 RIVERSIDE; CA JANUARY 22, 2003 01111 ��mm�t�Iat ,.a=.,; a. ` TITLE 24 REPORT Title 24 Report for: The Frana Residence Lot #286 @ The Hideaway La Quinta , CA 92253 Project Designer: BBG Architects 20-371 Irvine Ave. Suite 120 Santa Ana Heights, CA 92707-5651 (714) 434-4885 Report Prepared By: CJ McFadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, C :9-2t'1``"" !� LA IQUIN BUILD (760) 346-085 CITY O & SAFETY DEPT. APPR VEID FOR CONST ,d Job Number: �O /'�D4 Oph ti Date: Q� 3/2/2005 The EnergyPro comp u'te`r prop (n has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the Cal ifor i ergy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number. 3665 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 6 Form C -2R Computer Method Summary 8 Form ENV -3 Proposed Construction Assembly 14 HVAC System Heating and Cooling Loads Summary 15 Room Load Summary 19 Room Heating Peak Loads 23 Room Cooling Peak Loads 27 EnergyPro 3.1 By EnergySoft Job Number: User Number: 3665 f Certificate of Compliance: Residential (Part 1 of 2) CF -1 R The Frana Residence 3/2/2005 Project Title Date Lot #286 e. The Hideaway La Quinta Project Address Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 4,117 ft2 Average Ceiling Height: 11.2 ft Total Conditioned Slab Area: 3,315 f? Building Type: , (check one or more) Exterior Wall X1 Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ' ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (West) 270 deg Floor Construction Type: ®Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor ' BUILDING Component Const. Frame Assembly Location/Comments Tvpe U -Value (attic, garage, typica , etc. R-38 Roof (R.38.2xl4.16) Wood 0.024 Exterior Roof W-1 Wall (W.21.2x6.16) Wood 0.057 Exterior Wall Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insul.-tion FENESTRATION Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Left (North) 95.0 0.67 0.45 Bug Screen❑ X❑ Elx❑ Rear (East) 138.0 0.50 0.30 Bug Screen ❑ X❑ ❑ x❑ Right (South) 66.2 0.50 0.30 Bug Screen ❑ 0 ❑ 0 Right (South) 8.8 0.40 0.35 Bug Screen ❑ X❑ ❑ Q Front (West) 47.5 .0.50 0.30 Bug Screen ❑ 0 ❑ Q Left (North) 35.1 0.50 0.30 Bug Screen ❑ 0 ❑x❑ Left (North) 14.0 0.40 0.35 Bug Screen ❑ x❑ ❑ Q Rear (East) 55.0 0.67 0.45 Bug Screen ❑ X❑ ❑ x❑ Rear (East) 80.0 0.47 0.36, Bug Screen ❑ x❑ ❑ 0 Rear (East) 18.0 0.40 0.35 Bug Screen ❑ x❑ ❑ 0 Front (West) 35.0 0.67 0.45 Bug Screen ❑ Q ❑ 0 Front (West) 8.0 0.40 0.35 Bug Screen ❑ 0 ❑ 0 Run InitiationTime: 03/02/0513:25:53 Run Code: 1109798753 Ener Pro 3.1 By Ener Soft User Number: 3665 Job Number: Pa e:3 of 30 Certificate of Compliance: Residential (Part2 of 2) CF -1R ' The Frana Residence 3/2/2005 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. ' Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnare 80% AFUE Ducts in Attic 42 Setback HVAC -1 Central Furnare Central Furnace 80% AFUE 80% AFUE Ducts in Attic Ducts in Attic 42 4.2 Setback Setback HVAC -2 HVAC -3 ' Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -4 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 49 Sethack HVAC -1 Split Air Conditioner Split Air Conditioner Split Air Conditioner 14 0 SEER 14.0 SEER 14.0 SEER Ducts in Attic Ducts in Attic Ducts in Attic 42 4.2 4.2 Setback Setback Setback HVAC -2 HVAC -3 HVAC -4 WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A G Smith FGR -75 Large Gas Recirc/Time+Temp 2 76,000 76_ 0.72 0.0000 0.0 ' 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: CJ McFadden Title/Firm: BBG Architects Title/Firm: BREEZE AIR CONDITIONING Address: 20-371 Irvine Ave. Suite 120 Address: 75-145 ST. CHARLES PLACE Santa Ana Heights, CA 92707-5651 PALM DESERT, CA 92211 Telephone: 714 434-4885 Telephone: (760) 346-0855 Lic. #: t 3 o5 (signature)(da e)e) (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature/stamp) (date) Run Initiation Code6 1109798753 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:4 of 30 1 Certificate of Compliance: Residential (Addendum) CF -1 R 'The Frana Residence 3/2/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement anencv determines the adenuacv of the iustification_ and may reiect a buildino or desion that otherwise comnlies based on the adequacy of the special justification and documentation submitted. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 117 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 117 sqft Exposed Slab Floor, 4.00" thick at HVAC -1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1054 sqft Covered Slab Floor, 4.00" thick at HVAC -1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1570 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1570 sqft Exposed Slab Floor, 4.00" thick at HVAC -2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 174 sqft Covered Slab Floor, 4.00" thick at HVAC -2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 40 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -3 HIGH MASS Design(see C -21R) - Verify Thermal Mass: 40 sqft Exposed Slab Floor, 4.00" thick at HVAC -3 HIGH MASS Design(see C -21R) - Verify Thermal Mass: 360 sqft Covered Slab Floor, 4.00" thick at HVAC -3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC app-oved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. I Plan I Field The HVAC System "HVAC -1 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater muEt provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater muss provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. IRun Initiation Time: 03/02/05 13:25:53 Run Code: 1109798733 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:5 of 30 ' Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an ' asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ❑X 1150(.): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. * §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ❑X not apply to exterior mass walls). []'§150(d): Minimum R-13 raised Floor insulation in framed Floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. a§ 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑X §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures a§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. FX §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:6 of 30 I, Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach ised. Items marked with an ' asterisk (") may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) MI150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. IX -1 §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 3665 Job Number. Page:7 of 30 Computer Method Summary (Part 1 of 3) C -2R She -E a- es.idence 3/2/9n0 Project Title Date 10# 286 The_Hideaway La_Q.ui.ata Project Address Building Permit # BREEZEAl(760) 346-0855 plan Check/Date Documentation Author Telephone Computer�elfolmance 15 Field Cieck/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 4.44 4.93 -0.49 Space Cooling 38.48 37.13 1.35 Domestic Hot Water 6.92 5.05 1.87 Totals 49.85 47.11 2.73 Percent better than Standard: 5.5% BUILDING COMPLIES Total Conditioned Floor Area: 4,117 ft2 Floor Construction Type: ❑ Raised Floor[X] Slab Floor Building Type: Single Fam Detached Building Front Orientation: (West) 270 deg Total Fenestration Area: 14.6% Number of Dwelling Units: 1.00 Total Conditioned Volume: 46,114 ft' Number of Stories: 1 Total Conditioned Slab Area: 3,315 ft 2 BUILDING ZONE INFORMATION Zone Name Floor Area Volume .HVAC -1 .HVAC 2 _HVAG_3 _HVAC -4 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt 1,110 192-7 400 68Q Solar Gains Y/N .Roof 1_,11.0 -0-024- -345 0 Wall- 1.6.6_ _0...0.52 0. 90_ Wall_ x_4.0_ -0..0.57_ 9.0 -90- 90_Wall_ -Wall 691. 0.057 1.80 -90- 0Wall_ -Wall 1.84 0057_ 3Z0 90 Roof 1,.922 -0-024 _345 0 Wall_ 312 -0-057- -90- 0Wall_ Wall 363 -0-057- 90 90 Wall- 20_ _0 057 18D 9.0 Wall_ x.8.3_ 0._0.57 2709.0 .Roof- _900 -0-02-4- -345 0 Wall_ _245 -0-057- 0_ 90 Wall 14.5 _0.0.57_ 90 9D_ Wall- 52 0.057 180. 9.0_ Wall_ 38_ 0_057_ 270 9.0 _Root_ 68.0 0_024 -345 0 Wall- -344 -O-Q57- 0 90_ Wall_ _25.9 0_0.57 90 9.0_ Wall- 352- 0057 1.80 90 Wall- -266 --0-057- -27_0 90 1.2,099 -23,.8.9.5 6,.000 -6020 # of Units Zone Type -027_ Conditioned - _0_47 ---Conditioned- -0-10- --Gonditioned_ 0-11- _9.Rditione_d_ Form 3 Reference R--38R00f_(B 382x1416) Ws WaIL(W 21..2x6. t6.) W1 WaII_(W21..2x6.16.) W--J-WaII_(M21.2x616) W-J-\8LalL(W 21.2x616) -R--3-8-Roof-(R-38-2x1-4J-6)-- W--W_alL(W21..2x616) W--1-W-a.lL(W21.2x6 t6) W--tAa1L(W-21.2x616.) W--1L1NaUW_21.2x6 ] 6) R-38RooL(B38 2x1416) W=LW_alL(W212x6-J6) W-1 Wall (W.21.2x6 16) Ws WalL(W_ __21.2x6..1.6.) Ws-Wall_(W 21.2x616.) R38Roo.L(R _38.2x1416 ) yV-1 WalL(_W2-2x616) yV-1 Wall (W 2_-2x616.) W-1Wal.L(W21..2x6.16) W=LWa1LW.212x6.16) EVA -9 HVAC -2 .IiVAC-2 .HVAC -2 Thermostat Vent Type Hgt. Area -. etback- _nLa -6etback- 2 n/.a _Setback- n a -Eiatba&k- -n/ Location / Comments EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:8 of 30 1 Computer Method Summary (Part 2 of 3) C -2R The Frana Residen Project Title FENESTRATION SURFACES # Type Area Ll - Factor SHGC Act. Glazing Type Azm. Tilt 3/2/2005 Date Location/ Comments -1_ Win.d.ow_Left-----(&otth) -5.0_0_ 0_670 0A5 0_ _90 Fleetwao_d_Glazing�Lo/E) HVAC 2 Window Rear East 60.0 0.500 0.30 90 90 Fleetwood Glazing (Lo/E) HVAC -1 3 Window Right (South) 20.0 0.500 0.30 180 90 Fleetwood Glazing (Lo/E) HVAC -1 4 Window Right South 3.8 0.400 0.35 180 90 Fleetwood Glazing (Lo/E) HVAC -1 5 Window Right South 12.5 0.500 0.30 180 90 Fleetwood Glazing (Lo/E) HVAC -1 _6 Window Right (South 12.5 0.500 0.30 180 90 Fleetwood Glazing (Lo/E) HVAC -1 7 Windw i b o h 12.5_ 0.500 0.30 180 90 Fleetwood Glazing (Lo/E) HVAC -1 8 Window Right South 5.0 0.400 0.35 180 90 Fleetwood Glazing (Lo/E) HVAC -1 0_ Window Front (W�St)_ 37.5 0.502 0.30 270 90 Fleetwood Glazing (Lo/E) HVAC -1 J0 Window Left (North) 11.3 0.500 0.30 0 90 Fleetwood Glazing (Lo/E) HVAC -2 11 Window Left (North) 9.0 0.400 0.35 0 90 Fleetwood Glazing (Lo/E) HVAC -2 12 Window Left (North) 45.0 0.670 0.45 0 90 Fleetwood Glazing (Lo/E) HVAC -2 J3 Wiodow-BeaL---(East� _20.D -ABM -04.5_ ---90_ _90 Flee wDod_Glazu (.Lo1Q -HYAC-2 14 Window Rear (East) 23.0 0.500 0.30 90 90 Fleetwood Glazing (Lo/E) HVAC -2 15 Window Rear (East] 80.0 0.470 0.36 90 90 Fleetwood Glazing (Lo/E) HVAC -2 16 Window Rear (East) 6.0 0.400 0.35 90 90 Fleetwood Glazing (Lo/E) HVAC -2 17 Window Rear (East 6.0 0.400 0.35 90 90 Fleetwood Glazing (Lo/E) HVAC -2 18 Window Rear (East) 6.0 0.400 0.35 90 90 Fleetwood Glazing (Lo/E) HVAC -2 19 Window Left (North) 5.0 0,400 0.35 0 90 Fleetwood Glazing-(Lo/E) HVAC -3 20 Window Left North 11.3 0.500 0.30 0 90 Fleetwood Glazing (Lo/E) HVAC -3 21 Window Rear East_ 30.0 0.500 0.30 90 90 Fleetwood Glazing_( o/E) HVAC -3 .22. Window Right (South) 5.0 0.500 0.30. 180 90 Fleetwood Glazin _(Lo/E) HVAC -3 23 Window Left (North) 12.5 0.500 0.30 0 90 Fleetwood Glazing _L( o/E) HVAC -4 24 Window Rear East 25.0 0.500 0.30 90 90 Fleetwood Glazing (Lo/E) HVAC -4 25 Window Rear (East) 35.0 0.670 0.45 90 90 Fleetwood Glazing (Lo/E) HVAC -4 26 Window Right South 3.8 0.500 0.30 180 90 Fleetwood Glazing (Lo/E) HVAC -4 27 Window Front (West) 35.0 0.670 0.45 270 90 Fleetwood Glazing (Lo/E) HVAC -4 28 Window Front (West) 8.0 0.400 0.35 270 90 Fleetwood Glazing (Lo/E) HVAC -4 29 Window Front West 5.0 0.500 0.30 270 90 Fleetwood Glazing (Lo/E) HVAC -4 INTERIOR AND EXTERIOR SHADING Window Overhang_ Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 9 Bug Screen 0.76 4 Buq Screen 0.76 5 Bug Screen 0.76 6 Buy Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 -dug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 _ 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:9 of 30 1 Computer Method Summary (Part 2 of 3) C -2R Frana Residence 3/2/2005 'The Project Title Date FENESTRATION SURFACES Act. Glazing Type Location/ 'U- # Type Area Factor SHGC Azm. Tilt Comments _3.0. Wiad.ow_Eront (_West). —5.0- _0_500 —0-30. _27.0_ —9.0. Fleetwoad_G.lazing_(.Lo1E) 1iVAC-4 ' INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. ' 30 Bug Screen 0.76 Run initiation Time: 03/02/05 13:25:3 Run Code: 1109798753 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 10 of 30 1 ■ HVAC SYSTEMS Heating Equipment Minimum Distribution Type Computer Method Summary (Part 3 of 3) C -2R The Frana Residence Duct Thermostat Location / ' pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type 3/2/2005 Project Title Central Furnace 80% AFF EE Ducts in Attic 4.2 Setback HVAC -1 Date THERMAL MASS FOR HIGH MASS DESIGN 4.2 Setback HVAC -2 Central Furnace Area Thick. Heat Central Furnace Inside Location ' Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Tile in Mortar 117 07-5 _24 _0..6Z n/a 0 J±VAC_1JUnterior-Mass Concrete. Heavyweight 117 4_00 28 0_98 n/a Type (air conditioner, 0 HVAC -1 / Slab on Grade Concrete Heavyweight 1,054 4-00 28 0.98 n/a R -Value Type 2 HVAC -1 / Slab on Grade ' Tile in Mortar 1.570 0_75 24 0_67 n/a Split Air Conditioner 0 HVAC -2 / Interior Mass CodcLete. Jlea-v)weight 1,570 4.00 28 0.98 n/a 4.2 Setback 0 HVAC 2 / Slab on Grade PERIMETER LOSSES 14.0 SEER Ducts in Attic 4.2 Setback HVAC -4 WATER HEATING SYSTEMS ' F2 Insulation Water Heater Water Heater Distribution # in Input Cap. or Recovery Type Length Factor R -Val. Depth Location / Comments A.O.Smith FGR -75 Large Gas Recirc/Time+Temp Slab Perimeter —10 0.76 —0-0 0 HVAC -1 For large gas storage water heaters 117 O.Z6 —0-0 0 H-VACJ REMARKS 'Slab-Beometer Slab Perimeter 194 0.76 0.0 0 HVAC -2 Slab-edrnater _21 -026 —0-0. 0 FiVAC_2 Slab-Ber]mete.r 1_1 0.76 0_0 0 HVAC -3 ■ HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / ' pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80% AFF EE Ducts in Attic 4.2 Setback HVAC -1 Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -2 Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -3 Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -4 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. ' Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -1 Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -2 Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -3 _Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -4 WATER HEATING SYSTEMS Ratedl Tank Energy Fact! Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery 1 Standby R -Value System Name Type . Type Syst. Btu/hr_(gal) Efficiency Loss (%) Ext. A.O.Smith FGR -75 Large Gas Recirc/Time+Temp 2 76,000 75 0.:2 0.0000 0.0 ' 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy facto'. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Lcss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Computer Method Summary (Part 3 of 3) C-2R Frana Residence Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / 3/2/2005 'The Project Title WATER HEATING SYSTEMS Ratedl Tank Energk Fact? 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value Date THERMAL MASS FOR HIGH MASS DESIGN 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy facto. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Lcss. Area Thick. Heat Inside Location ' Type (sf) (in.) Cap. Cond. Form 3 Reference R-Val. Comments ncr L Heavyweias— 174 -4_0.0 --2E[_0-98. nta —2. -HVA-onJGrade Tile in Mortar 40 0.75 24 0.67 n/a 0 HVAC-3 / Interior Mass Concrete Heavyweight 4Q 4.00 28 0.98 n/a 0 HVAC 3 / Slab on Grade ' Concrete, Heavyweight 360 4_00 28 0_98 n/a 2 HVAC:-3 /.Slab on Grade PERIMETER LOSSES ' F2 Insulation Type Length Factor R-Val. Depth Location / Comments S11 b Perimeter 103 0.76 --O-Q _0 HVAC-3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments WATER HEATING SYSTEMS Ratedl Tank Energk Fact? 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy facto. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Lcss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 03/02/05 13:25:53 Run Code: 1109798753 _ EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Pa�12 �WC C -2R Computer Method Summary (AddEndum) 'The Frana Residence 3/2/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These iterrs require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 117 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 117 sqft Exposed Slab Floor, 4.00" thick at HVAC -1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1054 sqft Covered Slab Floor, 4.00" thick at HVAC -1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1570 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1570 sqft Exposed Slab Floor, 4.00" thick at HVAC -2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 174 sqft Covered Slab Floor, 4.00" thick at HVAC -2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 40 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 40 sqft Exposed Slab Floor, 4.00" thick at HVAC -3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 360 sqft Covered Slab Floor, 4.00" thick at HVAC -3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on aform CF -6R. I Plan I Field The HVAC System "HVAC -1 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Kun initiation i ime: usfurtu5'is:za:5s Kun f✓oae: viuututsias EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:13 of 30 1 i 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE The Frana Residence 3/2/2005 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 ASSEMBLY NAME W-1 Wall W.21.24.16 0.31 7 0.37 8 260 ASSEMBLY Floor INSIDE SURFACE AIR FILM 0.680 23.11 TYPE (check one) XWall LL w W Ceiling / Roof 14.81 FRAMING MATERIAL Wppd FF- p FRAMING % 15 pyo Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) THICK- NESS 4MING (in.) ❑ 0.875 ❑ 0.010 ❑ 0.375 © 5.500 ❑ 0.625 El El El ❑ — SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.31 7 0.37 8 260 9 0.68 INSIDE SURFACE AIR FILM THICK- NESS 4MING (in.) ❑ 0.875 ❑ 0.010 ❑ 0.375 © 5.500 ❑ 0.625 El El El ❑ — SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.175 0.175 0.060 0.060 0.465 0.465 21.000 5.445 0.562 0.562 0.31 263 0.37 0.98 260 0.26 0.68 0.680 0.680 23.11 7.56 RG Ri AI IB 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/s) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 846 0.20 1.69 006 0.35 0.02 1 06 0.29 0.31 263 0.37 0.98 260 0.26 0.68 14.81 TOTAL HC 3 7 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0433 X 0.85 --I+ [ 0.13231 X 0.15 1 / Rc 1 - (Fr-/. / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:14 of 30 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Frana Residence 3/2/2005 SYSTEM NAME FLOOR AREA HVAC -1 1,110 :ATING SYSTEM PSYCHROMETRICS 24.0 of 67.6 of Outside Air 83 cfm 69.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING P= -AK COIL HTG. PEAK CFM Sensiblel Latent 11CFM1 Sensible 1,207 24,597 3,223 493 20,507 0 1,230 1,025 0 0 83 3,193 1,898 83 4,092 0 0 1,230 1,025 30,27510=;:;0 HS26-060/G40UH60C-110 (5) 46,412 5,345 Total Adjusted System Output rAdiusted for Peak Design Conditions) 46,412 5,345 109.0 of Heating Coil 26,650 89,400 89,400 TIME OF SYSTEM PEAK Aig 2 pm Jan 12 am Supply Fan 2000 cfm 109.0 of -� Supply Air Ducts 108.6 of ROOMS 70.0 of �% Return Air Ducts "I OOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 114.1 / 80.3 of 80.0 / 65.4 of 58.6 / 57.1 of 58.6 / 57.1 of 310 :11114O SL pply Air Ducts Outside Air 83 cfm Cooling Coil Supply Fan 59.1 / 57.4 of 2000 cfmo ROOMS 78.6/64.7 of �% Return Air Ducts `S 43.2 /o R.H. 78.0 / 64.5 of EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 15 of 30 I'IHVAC SYSTEM HEATING AND COOLING LOADS SUMMARY ' PROJECT NAME DATE The Frana Residence 3/2/2005 SYSTEM NAME FLOOR AREA HVAC -2 1,927 ' ENGINEERING CHECKS SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts COIL COOLING P= -AK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 2,089 37,143 6,099 754 29,913 0 EATING SYSTEM PSYCHROMETRICS Airstream Temperatures 1,857 1,496 0 0 145 5,498 2,495 145 7,069 0 0 1,857 1,496 TOTAL SYSTEM LOAD 46 355 8,594 39,9731 HVAC EQUIPMENT SELECTION HS26-060/G40UH60C-110 (5) 44,766 8,807 89,400 Total Adjusted System Output 44,766 8,807 89,400 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 ann Note: values above given at ARI conditions ' EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 24.0 of 66.0 of 107.4 of 107.4 of Supply Air Ducts O Outside Air ' 145 cfm 106.7 of Heating Coil Supply Fan 2000 cfm ROOMS 70.0 of 69.3 of 1E #Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 114.1 / 80.3 of 81.4 / 67.5 of 60.7 / 59.3 of 60.7 / 59.3 of Supply Air Ducts O Outside Air ' 145 cfm Cooling Coil Supply Fan 61.5 / 59.6 of 2000 cfm-153.7% ROOMS R.H. of 78.0/66.1OF 78.9/66.4 ' Return Air Ducts I ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 16 of 30 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Frana Residence 3/2/2005 SYSTEM NAME FLOOR AREA HVAC -3 400 24.0 OF "� 0 Outside Air 30 cfm 69.8 of 14.1 / 80.3 OF 311� Outside Air 30 cfm 78.2/63.1 °F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 342 7,875 1,098 223 9,696 0 394 485 0 0 30 1,163 826 30 1,483 0 0 394 485 9,825F77;;25 12,148 HS26-060/G40UH60C-110 (5) 47,988 2,101 89,400 Total Adjusted System Output 47,988 2,101 89,400 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am PSYCHROMETRICS (Airstream Tei 69.10F 110.50F Heating Coil Supply Fan 2000 cfm 110.5 OF 30SLpply Air Ducts 110.3 OF ROOMS 70.0 OF 1% Return Air Ducts `S 78.7 / 63.4 OF 1111111 56.5 / 55.0 OF Cooling Coil of Cooli Supply Fa 2000 cfm 56.5 / 55.0 of Supply Air Ducts Fan 56.7/55.1OF X3.4% R.H. ROOMS 78.0 / 63.0 OF K Return Air Ducts 4 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:17 of 30 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Frana Residence 3/2/2005 SYSTEM NAME FLOOR AREA HVAC -4 680 SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING P= -AK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 798 17,461 1,749 232 9,956 0 873 498 0 0 5 1,965 1,315 51 2,520 0 0 873 1 498 21,172 3,064 13 472 HS26-060/G40UH60C-110 (5) 47,480 3,265 89,400 Total Adjusted System Output 47,480 3,265 89,400 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aig 2 pm Jan 12 am EATING 5Y5TEM P5YGHRUMETRIG5 Airstream Temperatures at I ime of Heating PeaK 24.0 of 68.6 of 110.0 of 110.0 of O Supply Air Ducts Outside Air � 51 cfm Heating Coil Supply Fan 109.8 of 2000 cfm ROOMS 69.8 of 70.0 of :DOLING SYSTEM PSYCHROMETRICS 14.1 / 80.3 of Outside Air 51 cfm 78.4/63,7 of T 79.3 / 64.2 of 57.3 / 55.9 of Cooling Coil Supply Fa 2000 cfm 57.3 / 55.9 of Supply Air Ducts Fan 57.7/56 . 0 of 45.2% R.H. ROOMS 78.0 / 63.6 of K Return Air Ducts Y EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:18 of 30 ROOM LOAD SUMMARY PROJECT NAME The Frana Residence DATE 3/2/2005 SYSTEM NAME HVAC -1 FLOOR AREA 1,110 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -1 HVAC -1 1 1,207 24,597 3,223 1,207 24,597 3,223 493 20,507 PAGE TOTAL 1 1,207 24,597 3,223 493 20,507 TOTAL 1 1,207 24,597 3,223 493 20,507 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:19 of 30 1 ROOM LOAD SUMMARY PROJECT NAME The Frana Residence DATE 3/2/2005 SYSTEM NAME HVAC -2 FLOOR AREA 1,927 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -2 HVAC -2 1 2,089 37,143 6,099 2,089 37,143 6,099 754 29,913 i f PAGE TOTAL 1 2,0891 37,14: 6,099 754 29,913 TOTAL 1 2,089 37,14116,099 754 29,913 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:20 of 30 II �kOOM LOAD SUMMARY PROJECT NAME The Frana Residence DATE 3/2/2005 SYSTEM NAME HVAC -3 FLOOR AREA 400 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -3 HVAC -3 1 342 7,875 1,098 342 7,875 1,098 223 9,696 i PAGE TOTAL 1342 7,87E 1 1,098 223 9,696 TOTAL 1 342 7,87° 1 1,098 223 9,696 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:21 of 30 �ROOM LOAD SUMMARY PROJECT NAME DATE The Frana Residence 3/2/2005 SYSTEM NAME FLOOR AREA HVAC -4 680 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -4 HVAC -4 1 798 17,461 1,749 798 17,461 1,749 232 9,956 PAGE TOTAL 1 798 17,46' 1,749 232 9,956 TOTAL 1 798 17,46' 1,749 232 9,956 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 22 of 30 [1200M HEATING PEAK LOADS Project Title Date The Frana Residence 3/2/2005 Room Information Design Conditions Room Name HVAC -1 Time of Peak Jan 12 am Floor Area 1,110 Outdoor Dry Bulb Temperature 24°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value LT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Fagg Total: 15,5001 Infiltration: [ 1.001 x 1.080 x 1=i x 10.90 x 0.50 / 60] x 46 = 5 007 Schedule Air Sensible Area Ceiling Height ACH CT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 20,507 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:23 of 30 1110.0 X x X x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0243 x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 1,242 1,181.2 0.0566 46.0 3,077 50.0 0.6700 46.0 1,541 155.0 0.5000 46.0 3,565 8.8 0.4000 46.0 161 perimeter =130.0 45.5 5,915 Items shown with an asterisk (') denote conduction through an interior surface to another room. Fagg Total: 15,5001 Infiltration: [ 1.001 x 1.080 x 1=i x 10.90 x 0.50 / 60] x 46 = 5 007 Schedule Air Sensible Area Ceiling Height ACH CT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 20,507 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:23 of 30 `ROOM HEATING PEAK LOADS ' Project Title Date The Frana Residence 13/2/2005 Room Information Desi n Conditions ' Room Name HVAC -2 Time of Peak Jan 12 am Floor Area 1,927 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr ' Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 20024 Infiltration: [ 1.001X 1.080 x 1 927 x 12.40 x 60] x 46 = 9 888 Schedule Air Sensible Area Ceiling Height ACH pr Fraction 'F TOTAL HOURLY HEAT LOSS FOR ROOM 29,913 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 24 of 30 1927.0 x x x X x x x x x X x X x x X x x x x X x x X x x x X x x x X X X X x X x x x 0.0243 x x X x X X x x x X x x x X x x X x x x X X x x X X x x X x x X x x x x X x x 46.0 = = = = = = = = = = = = = = = = = = 2,155 1,177.7 0.0566 46.0 3,068 34.3 0.5000 46.0 789 27.0 0.4000 46.0 497 65.0 0.6700 46.0 2.003 80.0 0.4700 46.0 1,730 perimeter = 215.0 45.5 9,782 ' Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 20024 Infiltration: [ 1.001X 1.080 x 1 927 x 12.40 x 60] x 46 = 9 888 Schedule Air Sensible Area Ceiling Height ACH pr Fraction 'F TOTAL HOURLY HEAT LOSS FOR ROOM 29,913 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 24 of 30 DOOM HEATING PEAK LOADS 7:� ' Project Title Date The Frana Residence 3/2/2005 Room Information Desi n Conditions ' Room Name HVAC-3 Time of Peak Jan 12 am Floor Area 400 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value /nT of Btu/hr ' Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 8 041 Infiltration: I 1.001X 1.080 X 400 x 10.00 X 0.50 / 60] x 46 = 1 655 Schedule Air Sensible Area Ceiling Height ACH aT Fraction 'r TOTAL HOURLY HEAT LOSS FOR ROOM 9,696 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 25 of 30 400.0 X x X x x X X x x X x x X x x x X x X x X x X x X X x x x x X X X X X X X X X 0.0243 X X X x x X X X X x x X X X X X x X x x X X X x x x X X X X X X x x x X X X X 46.0 = = = = = = = = = = = = = = = = 447 479.7 0.0566 46.0 1,249 5.0 0.4000 46.0 92 46.3 0.5000 46.0 1,065 eri meter = 114.0 45.5 5,187 ' Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 8 041 Infiltration: I 1.001X 1.080 X 400 x 10.00 X 0.50 / 60] x 46 = 1 655 Schedule Air Sensible Area Ceiling Height ACH aT Fraction 'r TOTAL HOURLY HEAT LOSS FOR ROOM 9,696 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 25 of 30 ' ROOM HEATING PEAK LOADS Project Title Date The Frana Residence 3/2/2005 --j Room Information Desicin Conditions t Room Name HVAC -4 Time of Peak Jan 12 am Floor Area 680 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value /LT of Btu/hr ' Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 7 424 Infiltration: [ 1.00 I x 1.080 x 680 x 9.00 x 60] x 46 = 2 533 Schedule Air Sensible Area Ceiling Height ACH Inr Fraction ' TOTAL HOURLY HEAT LOSS FOR ROOM 9,956 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 26 of 30 680.0 X x X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0243 X X X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 761 1,220.8 0.0566 46.0 3,180 51.2 0.5000 46.0 1,179 70.0 0.6700 46.0 2,157 8.0 0.4000 46.0 147 680.0 0.2985 0.0 0 ' Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 7 424 Infiltration: [ 1.00 I x 1.080 x 680 x 9.00 x 60] x 46 = 2 533 Schedule Air Sensible Area Ceiling Height ACH Inr Fraction ' TOTAL HOURLY HEAT LOSS FOR ROOM 9,956 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 26 of 30 ' RESIDENTIAL ROOM COOLING LOAD SUMMARY ' The Frana Residence 3/2/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-38 Roof R.38.2x14.16 -1 Wall W.21.2x6.16 Fleetwood Glazing Lo/E Fleetwood Glazing_ Lo/E Fleetwood Glazin Lo/E Area U -Value 1,110. 1.181.2 X 1 0.05661 HVAC -1 780E 115°F 37°F X X X X X ETD 1 = = = = = Btu/hr 56.0 1,511 35.6 2,381 37.0 1,240 37.0 2,868 37.0 130 X X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 8,129 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FrnchDr 117 X X x x x X x X X x Csm. n1VWdw_(118.) CsmntWdw(119) _(North) (East) _(Lo u t h FXdGIsWdW 120 _South CsmntWdw (12 1) (South) CsmntWdw(122) (South) CsmntWdw 123 (South) FxdGlsWdw 124 (South) CsmntWdw (125) (West) 1,463 ( 0.0 ( 0.0 X X x x x X x X X x 1 + + + + + + + + + + 50.0 x X x x X x X X X x 15)'X )X )x )x )..x )X ) x ) X )x 0.501 = = = = = = = = _ = 376 ( 0.0 1 60.0 73 0.334 1,463 ( 0.0 1 20.0 32 0.334 214 ( 0.0 15 3.8 32 0.390 47 ( 0.0 1 12.5 32 0.334 134 ( 0.0 1 12.5 32)X 0.334 134 ( 0.0 15 12.5 32 0.334 134 ( 0.0 15 5.0 32 0.390 62 ( 0.0 15 37.5 73 0.334 914 ( Sched. Page Total 3 a7s Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,110 x 0.500 Watts/sqft x 3.412 Bt..thlWatt = 1,894 Occupants 1.00 X 1,110 X 250 Btuh/OCC. / 200 sgft/occ. = 1,388 Receptacle 1.00 x 1,110 x 1.500 Watts/sqft x 3.413 Btih[Watt = 5,683 Process 1.00 x 1,110 X 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration:1..Qo x x 1.110 xoho x 0_50 / 60] Schedule Air Sensible Area Ceiling Height ACH �T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,5971 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 1 110 x 200 Btuh/occ. / 200 sgft/occ. = 1 110 Receptacle 1.00 x 1 110 x 0.000 Watts/sgft x 3.41 BtuhlWatt = 0 Process 1.00 X 1 110 X 0.000 Watts/sqft x 3.a1 B1uhMatt = o Infiltration: C 1.00 x 4840 x 1 11 x Heigh x 60] 000433 = 2 113 Schedule Air Latent Area Ceiling Height ACH GyV Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,223 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 27 of 30 1 t RESIDENTIAL ROOM COOLING LOAD SUMMARY ' The Frana Residence 3/2/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X t. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (-) denote conduction through an interior surface to another room. DETD' 56.0 35.6 37.0 37.0 37.0 37.0 Fage Total HVAC -2 780F 115°F 370E Btu/hr 2,624 2,374 - 635 - 400 1,611 1 391 9 035 Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr CsmntWdw 106 (North) xtIGls-W-dw_(] 12) (North) FrnchDr 114 (North) FrnchDr 111 East CsmntWdw (113) (East) Sld GIsDr 115 (East) FXdGISWdW 126 (East) FxdGISWdW 127 (East) FxdGlsWdw (128) (East) 45.0 ( 0.0 X x+ x+ X11, X+ X x X x x + + + + + + + 11.3 x X X x x x x x X x 15 )x ).x >X x Ax 0.334 = = = = = = = = __ 57 ( 0.0 9.0 15 0.390 53 ( 0.0 45.0 15 0.50 338 ( 0.0 20.0 73)-x 0.50 731 ( 0.0 23.0 73)x 0.334 561 ( 0.0 15 80.0 73)x 0.40 2,340 ( 0.0 1 6.0 73) 0.390 171 ( 0.0 1 6.0 73)X 0.390 171 ( 0.0 15 6.0 73x 0.390 171 ( I= ' Sched. Page Total 4 592 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,927 x 0.500 Watts/sgft x 3.41 Btah[Watt = 3,288 Occupants 1.00 X 1,927 X 250 Btuh/occ. / 200 sgftlocc. = 2,409 ' Receptacle 1.00 x 1,927 x 1.500 Watts/sgft x 3.413 Btlh/Watt _ 9,865 Process �1.000xx 1,927 x 0.000 Watts/sqft x 3.413 BtjhlWatt 0 Infiltration: � 1.00 x U...O80 x 1.,.922 x 2,40 x 050 / 60] [L�--3 = 2,959 Schedule Air Sensible Area Ceiling Height ACH Lir Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 37,143 ' Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 927 x 200 Btuh/occ. / 200 scft/occ. = 1 927 ' Receptacle 1.00 x 1 927 x 0.000 Watts/sgft X 3.41 Btuh/Waft = 0 Process r 1.00 x 1 927 x 0.000 Wafts/sgft x 3.41 Btluh/Waft = 0 Infiltration: II 1.00 x L 4,8401 x 1 927 x 12.40 x 0.50 / 60] 0100433 = 4 172 ' "` chedule Air Latent Area Ceiling Height ACH �yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,099 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 28 of 30 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Frana Residence 3/2/2005: Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: HVAC -3 78°F 115°F 37°F Conduction Area U -Value DETD 1 Btu/hr X X X X X X X x X X X X X X X X X X 56.0 = = = = = = = = = 545 35.6 967 37.0 74 37.0 857 Shaded Unshaded 1. Design Equivalent Temperature Difference (DETD) Page Total 2442 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr FxdGlsWdw 107) _(North) ( 0.0 X 1 + 5.0 X 15 ).K 0.390 = 29 CsmntWdw (10.R1 (North) ( 0.0 X 1 + 11.3 x 15 )_K 0.334 = 57 CsmntWdw i 110 (East) ( 0.0 x 15 + 30.0 x 73) K 0.334 = 731 CsmntWdw 109 (South) ( 0.0 X 1 + 5.0 X 32) K 0.334 = 53 ( x + X )K ( x + x )K ( x + x )K = ( x + X )K ( X + X )K Sched. Page Total 871 ' Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 400 X 0.500 Watts/sqft x 3.41 Btuh/Watt = 683 Occupants 1.00 x 400 x 250 Btuh/occ. / 200 sgft/occ. = 500 ' Receptacle 1.00 x 400 X 1.500 Watts/sqft x 3.413 BtuhlWatt _ 2,048 Process 1.00 x 400 x 0.000 Watts/sqft x 3.41Btuhh[Watt 0 Infiltration: QO x 1 1.0.8.0 x 400 x 0_00 0_5o x / 60] EX37 = ' Schedule Air Sensible Area Ceiling Height ACH LSI Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7875 ' Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 400 x 2001 Btuh/occ. / 200 sq-:Uocc. = 400 ' Receptacle 1.00 x 400 x 0.000 Watts/sgft X 3.41 BtahMatt = o Process 1.00 x 400 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: CSchedule X Air Latent nt0 x Area 40 x Ceiling Height x ACH 50 / 60] Z -\W0433 = 698 ' Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,098 tEnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 29 of 30 ' 4 ` f, RESIDENTIAL ROOM COOLING LOAD SUMMARY The Frana Residence 3/2/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value 680. DETD 1 X 56.0 X 35.6 X 37.0 X 37.0 X 37.0 X 0.0 X X X 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded HVAC -4 780E 115°F 37°F Btu/hr 926 2,461 948 1,735 118 0 6 189 Solar Gain Orientation Area SGF Area SGF SC Btu/hr CsmntWdw 206) (North)_ CSmnLWdw (207) (East) FrnchDr 208 (East) CsmntWdw 201 (South) FrnchDr (202) (West) FxdGlsWdw 203 (West) CsmntWdw 204 (West) CsmntWdw 205 (West) 609 ( 0.0 1 35.0 ( 0.0 x x x x x x x x X xE 15 + + + + + + + + + + 12.5 x X x x x X X x X x 15)X ) x )X x x X x )x )x 0.334 = = = = = = = = = = 63 ( 0.0 15 25.0 73 0.334 609 ( 0.0 1 35.0 73 0.50 1,280 ( 0.0 15 3.8 32) 0.334 40 (-0.0 15 35.0 73) 0.50 1,280 ( 0.0 1 8.0 73) 0.390 228 ( 0.0 15 5.0 73)X 0.334 122 ( 0.0 1 5.0 73) 0.334 122 ( ( Sched. Page Total 3 743 ' Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 680 x 0.500 Watts/sqft x 3.413 Btuh/Waft = 1,160 Occupants 1.00 X 680 X 250 Btuh/occ. / 200 sgft/occ. = 850 ' Receptacle 1.00 x 680 x 1.500 Watts/sgft x 3.413 Btuh/Waft _ 3,481 Process 1.00 X 6800x�x 0.000 Wafts/sqft x 3.41 Btuh/Waft 0 Infiltration: 00 x 1.080 x --68o x 9 oo x 0..50 / 60] =::]� = 2 037 Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17461 ' Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 680 x 200 Btuh/occ. / 200 sgft/occ. = 680 Receptacle 1.00 x 680 x 0.000 Watts/sgft x 3.413 Btuh/Waft = 0 Process 1.00 x 680 x 0.000 Watts/sqft x 3.41 Btuh/Waft = 0 Infiltration: C tool x L 4,8401 x 68 x 9.00 x 0.50 / 60] 0.00433 = 1 069 ' Schedule AIr Latent Area Ceiling Height ACH �W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,749 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 30 of 30