Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
12-0830 (AR)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 12-00000830 Property Address: 53749 VIA PISA APN: 772-530-051- - - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 35000 Applicant: Architect or Engineer: NA LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 807645 r J Date: Contractor: O NER-BUILDEA DECLARATION , I hefeby affirm under penalty of perjury that I am exempt from -the Contractor's State License Law for the following rcason (Soc. 7031.6, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1—) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I—) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: FRANA,JACQUELINE R 6055 LAKE GENEVA DR RENO, NV 89511 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/13/12 Contractor: D=TE-P1 (nA U SCRIVENS CONSTRUCTION INC, GL P.O. BOX 13302 PALM DESERT, CA 92255 (760)837-9918 Lic. No.: 807645 CITY OF LA QUINTA ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 902363512 _ I certify that, in the performance of the work fpr which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if 1 should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I half with comp) r ith those provisions. Date:6 Applicant: WARN( G: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives ✓ �oo�f this county to enter upon the above-mentioned propertofsp tion purpo s. rwate: l� Signature (Applicant or Agent): 1� it LQPERMIT a Application Number . . . . . 12-00000830 ------ Structure Information 150SF ADDITION/VB/RES-3/CLASS A -FR [ENG] ----- Other struct info . . . . . CODE EDITION 2010 FLOOD ZONE NO PATIO SQ FTG 102.00 1ST FLOOR SQUARE FOOTAGE 150.00 ---------------------------------------------------------------------------- PermitBUILDING PERMIT Additional desc . Permit Fee 317.00 Issue Date . . . . Expiration Date . . 3/12/13 Plan Check Fee . . 206.05 Valuation . . . . 35000 Qty Unit Charge Per Extension BASE FEE 252.00 10.00 6.5000 THOU BLDG 25,001-50,000 65.00 ---------------------------------------------------------------------------- Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . . . 20.25 Plan Check Fee . Issue Date . . . . Valuation . . . . Expiration Date . . 3/12/13 5.06 0 Qty Unit Charge Per Extension BASE FEE 15.00 150.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 5.25 ---------------------------------------------------------------------------- Permit MECHANICAL Additional desc . . Permit Fee . . . . 19.50 Issue Date . . . . Expiration Date . . 3/12/13 Plan Check Fee . . 4.88 Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 ---------------------------------------------------------------------------- Special Notes and Comments 78SF PATIO AND 72SF ENTRY ENCLOSURES WITH 102SF DECK/VB/RES-3/CLASS A -FR [ENGINEERED] THIS PERMIT DOES NOT INCLUDE ADDITION TO EXISTING BUILDING FOOT PRINT OR PLUMBING INSTALLATIONS. 2010 CALIFORNIA BUILDING CODES. September 13, 2012 4:59:43 PM AORTEGA Application Number . . . . . 12-00000830 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 ENERGY REVIEW FEE 20.61 STRONG MOTION (SMI) - RES 3.50 Fee summary Charged Paid Credited -------------------- Due ----------------- Permit Fee Total ---------- 356.75 ---------- .00 .00 356.75 Plan Check Total 215.99 .00 .00 215.99 Other Fee Total 26.11 .00 .00 26.11 Grand Total 598.85 .00 .00 598.85 LQPERMIT Bin.# City 0f to QUlnu'a Building 8i: Safety Division Perinit # Q,3Q P.O. Box 1504,78-49S Calle Tampico (a.Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: J . % 1-119 V-11A Owner's Name:. A. P. Number. Address: 53 7t f g Legal Description: &3 - 7 4 3 4 Contractor. C� e� Ci / t/ 'v titi City, ST, Zip: � .'.c.. gys' Telephone: u -.€ �s ;x Address: -)Cf 8; !E p �`p �. t DT Project Descriptionaf City, sT, zip: 6 n sS:t Telephone: I> 937 1 City Lic. #: State Lic. # : gp') 41V-5- P SCO der Arch, Engr., Designer: OC 1,,,Ip A •S 4,4 <S 3 f J v Address: City, ST, Zip: Telephone: State Lic. w Construction Type• . Occupancy: Project type (circle one): New dd'n alter Repair Demo Sq. Ft.:/S� # Stories: #units: Name of Contact Person:% 1 ejo Telephone # of Contact Person: ?Ico 3 I, Estimated Value of Project 3s 'V-> t> APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Rcq'd Ree'd TRACKING PERMIT FEES Plan Stu Plan Check submitted ! ? 2i0 Item Amount Structural Cales. 49 Reviewed, ready for corrections It Plan Check Dep )sit. Truss Calcs. Called Contact Person Plan Check Bale net. Title 24 Cales. a Plans picked up I J . Construction Flood plain plan Pians resubmitted Z HI� Mecharilcal Grading plan P! Review, ready for correedo Electrical Subcoatactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE: '"' Review; ready for corrections/issue Developer Imp ret Fee Planning Approval Called Contact Person .LP.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Bees lRbs loin- e,jn��,1- Ns�Q-w. � "UiWhella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK N: FINMALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Hideaw y Date: September 14, 2012 Owner's Name: Jacqueline Frana Phone No. 760-831-7439 Project Address: 53-749 Via Pisa, LaQuinta, CA Project Description: Addition to existing SFD APN: 772-530-011 Tract #: Type of Development: Residential XX Total Square Feet of Building Area Commercial 150 Lot #'s: Industrial Certification of Applicant/Owners: The person signing certifies that the above information is corre:t and makes this statement under penalty of perjury and further represents that he/she is authorized to sign olbehalf of thp'owneddeveloper. Dated: September 14, 2012 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PRO CT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Note: Number of Sq.Ft. 150 Pursuant to AB 181 any room additions or enclosures of 500 Amount per Sq.Ft. $0.00 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within -:he same school district's Amount Collected $0.00 jurisdiction are exempt from developer fees. Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Laurie Howard, Secretary Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts an the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. NIV:c/nl.,does/de\,fees/Certificate of compliance form updated 3-2(N)7 11/2010 0 BUILDING ENERGY ANALYSIS REPORT PROJECT: Frana Remodel 53-749 Via Pisa La Quinta , CA 92253 Project Designer: . Ochoa Design Associates 73-626 Highway 111 Palm Desert, CA 92260 (760) 773-6605 Report Prepared by: Scott DeVoe BREEZE AIR CONDITIONING 75-145 St. Charles Place Palm Desert, CA 92211 (760) 346-0855 AUG 2 2 2012 I • eau aw 0 LA QUINTA BUILDING & SAFETY DEPT. Job Number: APPROVED FOR CONSTRUCTION Date: 8/20/2012 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Buildirg Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number. 3665 RunCode: 2012-08-20T14:41:01 ID: TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads EnergyPro 5.1 by EnergySoft Job Number ID: User Number: 3665 1 2 3 11 14 18 22 27 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Frana Remodel Building Type ® Single Family ❑ Addition Alone ❑ Multi Family la Existing+ Addit on/Alteration Date 8/20/2012 Project Address 53-749 Via Pisa La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,267 Addition 150 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes 0 No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-19 4,117 Existing Wall Wood Framed R-13 4,127 Existing Slab Unheated Slab -on -Grade None 3,315 Perim = 459' Existing Roof Wood Framed Attic R-38 150 New Wall Wood Framed R-21 132 New Slab Unheated Slab -on -Grade None 150 Perim = 24' New Floor Wood Framed w/Crawl Space R-13 680 Existing FENESTRATION U- Exterior Orientation Area Factor SHGC OverhangSidefins Shades Status Right (N) 66.3 0.790 0.59 none none Bug Screen Existing Right (N) 8.8 0.710 0.60 none none Bug Screen Existing Front (E) 47.5 0.790 0.59 none none Bug Screen Existing Left (S) 50.0 0.770 0.59 none none Bug Screen Existing Rear (IM 115.0 0.790 0.59 none none Bug Screen Existing Left (S) 35.1 0.790 0.59 none none Bug Screen Existing Left (S) 14.0 0.710 0.60 none none Bug Screen Existing Left (S) 45.0 0.770 0.59 none none Bug Screen Removed Rear (VV) 55.0 0.770 0.59 none none Bug Screen Existing Rear (1/10 23.0 0.790 0.59 none none Bug Screen Removed Rear (Vlq 80.0 0.470 0.36 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setbwk Existing 2 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setbwk Existing 1 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setbmk Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC -1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing HVAC -2 Ducted Ducted Attic, Ceiling Ins, vented . 4.2 Existing HVAC -3 Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2012-08-20T14:41:01 ID: Page 3 of 31 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Frana Remodel Building Type ® Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addit on/Alteration Date $/20/2012 Project Address 53-749 Via Pisa La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor AreF- 4,267 Addition 150 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes 0 No HERS Measures -- If Yes, A CF-4R must be provided per Par- 2 of 5 of this form. El Yes ❑ No Special Features -= If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Par 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Rear (149 18.0 0.710 0.60 none none Bug Screen Existing Front (E) 58.5 0.690 0.24 1.0 none Bug Screen New Left (S) 41.3 0.330 0.24 1.0 none Bug Screen New Rear (lAq 33.3 0.330 0.24 1.0 none Bug Screen New Front (E) 35.0 0.770 0.59 none none Bug Screen Existing Front (E) 8.0 0.710 0.60 none none Bug Screen Existing HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setba:k Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status HVAC-4 Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number 3665 RunCode: 2012-08-20T14:41:01 ID: Page 4 of 31 PERFORMANCE CERTIFICATE: Residential (Part :2 of 5) CF -1 R Project Name Frana Remodel Building Type ® Single Family ❑ Addition AlonE ❑ Multi Family m Existing+ Add tion/Alteration Date 1812012012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These iterrs require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Existing Water Heater Standard Gas 50 gal. has an EF less than the Vintage Defaults. Field verification is required. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The in3pector must receive a completed CF -4R form for each of the measures listed below for final to be given. Ener Pro 5.1 by En ergySoft User Number: 3665 RunCode: 2012-08-20714:41:01 /D: Pae 5 of 31 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Frana Remodel 1 ❑ Multi Family m Existing+ Addition/Alteration $/20/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 10.00 10.41 -0.40 Space Cooling 150.60 149.24 1.36 Fans 26.76 26.56 0.20 Domestic Hot Water 11.35 11.35 0.00 'Pumps 0.00 0.00 0.00 Totals 198.72 197.56 1.16 Percent Better Than Standard: 0.6% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall area Area Number of Dwelling Units: 1.00 (E) 1,161 149 Fuel Available at Site: Natural Gas (S) 1,293 140 Raised Floor Area: 680 (M 1,281 301 Slab on Grade Area: 3,465 (N) 1,190 75 Average Ceiling Height: 11.2 Roof 4,267 0 Fenestration Average U -Factor: 0.68 TOTAL: 666 Average SHGC: 0.49 Fenestration/CFA Ratio: 15.6 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards. of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author C ompany BREEZE AIR CONDITIONING '`//�� 8/20/2012 Address 75-145 St. Charles Place Name Scott DeVoe Cit /State/Zi Palm Desert, CA 92211 Phone (760) 346-0855 Signed Date The individual with overall design responsibility hereby certifies that the proposed building deign represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building env ;lope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company. Ochoa Design Associates Address 73-626 Highway 111 Name Juan Cartoc Och a $ City/State/Zip Palm Desert, CA 92260 Phone (760) 773-6605 Signed License # Date EnerqvPro 5.1 by Ener Soft User Number: 3665 RunCode: 2012-08-20714:41:01 ID: Page 6 of 31 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R Project Name Frana Remodel Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 8/20/2012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity -Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,110 0.049 R-19 345 0 Existing 4.2.1-A4 HVAC -1 Wall 691 0.102 R-13 0 90 Existing 4.3.1-A3 HVAC -1 Wall 185 0.102 1 R-13 90 90 Existing 4.3.1-A3 HVAC -1 Wall 166 0.102 R-13 1 1 1 180 90 1 Existing 4.3.1-A3 HVAC -1 Wall 140 0.102 R-13 270 90 Existing 4.3.1-A3 HVAC -1 Slab 1,171 0.730 None 0 180 Existing 4.4.7-A1 HVAC -1 Roof 1,927 0.049 R-19 345 0 Existing 4.2.1-A4 HVAC -2 Wall 20 0.102 R-13 0 90 Existing 4.3.1-A3 HVAC -2 Wall 483 0.102 R-13 901 90 Existing 4.3.1-A3 HVAC -2 Wall 357 0.102 R-13 180 90 Existing 4.3.1-A3 HVAC -2 Wall 386 0.102 R-13 270 90 Existing 4.3.1-A3 HVAC -2 Slab 1,744 0.730 None 0 180 Existing 4.4.7-A1 HVAC -2 Roof 1501 0.026 R-38 0 0 New 4.2.1-A9 HVAC -2 Wall 41 0.069 R-21 90 90 New 4.3.1-A6 HVAC -2 Wall 42 0.069 R-21 1801 90 New 4.3.1-A6 HVAC -2 Wall 501 0.069 R-21 2701 90 New 4.3.1-A6 HVAC -2 FENESTRATION SURFACE DETAILS ID I Type Area Ll -Factor' SHGC2 Azm Status Glazing Type Location/Comments 1 Window 20.0 0.790 Default 0.59 Default 0 Existing Wood Clad Oper (Lo/E) HVAC -1 2 Window 3.8 0.710 Default 0.60 Default 0 Existing Wood Clad Fix (Lo/E) HVAC -1 3 Window 12.5 0.790 Default 0.59 Default 0 Existing Wood Clad Oper (Lo/E) HVAC -1 4 Window 12.5 0.790 Default 0.59 Default 0 Existing Wood Clad Oper (Lo/E) HVAC -1 5 Window 1 12.5 0.790 Default 0.59 Default 0 Existing I Wood Clad Oper (Lo/E) HVAC -1 6 Window 5.0 0.710 Default 0.60 Default 0 Existing Wood Clad Fix (Lo/E) HVAC -1 7 Window 37.5 0.790 Default 0.59 Default 90 Existing Wood Clad Oper (Lo/E) HVAC -1 8 Window 50.0 0.770 Default 0.59 Default 180 Existing Wood Clad Door (Lo/E) HVAC -1 9 Window 60.0 0.790 Default 0.59 Default 270 Existing Wood Clad Oper (Lo/E) HVAC -1 10 Window 11.3 0.790 Default 0.59 Default 180 Existing Wood Clad Oper (Lo/E) HVAC -2 11 Window 9.0 0.710 Default 0.60 Default 180 Existing 1 Wood Clad Fix (Lo/E) HVAC -2 12 Window 1 45.0 0.770 Default 0.59 Default 180 Removed Wood Clad Door (Lo/E) HVAC -2 13 Window 20.01 0.770 Default 1 0.59 Default 270 Existing Wood Clad Door (Lo/E) HVAC -2 14 Window 23.0 0.790 Default 0.59 Default 270 Removed Wood Clad Oper (Lo/E) HVAC -2 15 Window 80.0 0.470 NFRC 0.36 NFRC 270 Existing Wood Clad SGD (Lo/E) HVAC -2 16 Window 6.0 0.710 Default 0.60 Default 270 Existing Wood Clad Fix (Lo/E) HVAC -2 (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHG Window H t Wd Ove hanq Left Fin Len H t LExt RExt Dist Len Ri ht Fin H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 JBug Screen 0.76 16 JBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2012-08-20714:41:01 ID: Pae 7 of 31 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Frana Remodel Building Type la Single Family ❑ Addition Alore ❑Multi Family m Existing+ Addition/Alteration Date $/20/2012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appe idix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 150 0.730 None 0 180 New 4.4.7-A1 HVAC -2 Roof 400 0.049 R-19 345 0 Existing 4.2.1-A4 HVAC -3 Wall 52 0.102 R-13 0 90 Existing 4.3.1-A3 HVAC -3 Wall 38 0.102 R-13 901 90 Existing 4.3.1-A3 HVAC -3 Wall 245 0.102 R-13 180 90 Existing 4.3.1-A3 HVAC -3 Wall 145 0.102 R-13 270 90 Existing 4.3.1-A3 HVAC -3 Slab 400 0.730 None 0 180 Existing 4.4.7-A 1 HVAC -3 Roof 680 0.049 R-19 345 0 Existing 4.2.1-A4 HVAC -4 Wall 352 0.102 R-13 0 90 Existing 4.3.1-A3 HVAC -4 Wall 266 0.102 R-13 90 90 Existing 4.3.1-A3 HVAC -4 Wall 344 0.102 R-13 180 90 Existing 4.3.1-A3 HVAC -4 Wall 259 0.102 R-13 270 90 Existing 4.3.1-A3 HVAC -4 Floor 680 0.046 R-13 0 180 Existing 4.4.1-A3 HVAC -4 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 17 Window 6.0 0.710 Default 0.60 1 Default 270 Existing Wood Clad Fix (Lo/E) HVAC -2 18 Window 6.0 0.710 Default 0.60 Default 270 Existing Wood Clad Fix (Lo/E) HVAC -2 19 Window 58.5 0.690 NFRC 0.24 NFRC 90 New Iron or (Low/E-SB60) HVAC -2 20 Window 41.3 0.330 NFRC 0.24 NFRC 180 New Wood Clad (Lo/E-240) HVAC -2 21 Window 33.3 0.330 NFRC 0.24 NFRC 270 New Wood Clad (Lo/E-240) HVAC -2 22 Window 5.0 0.790 Default 0.59 Default 0 Existing Wood Clad Oper (Lo/E) HVAC -3 23 Window 5.01 0.710 Default 0.60 Default 180 Existing Wood Clad Fix (Lo/E) HVAC -3 24 Window 11.3 0.790 Default 0.59 Default 180 Existing Wood Clad Oper (Lo/E) HVAC -3 25 Window 30.0 0.790 Default 0.59 Default 270 Existing Wood Clad Oper (Lo/E) HVAC -3 26 Window 3.8 0.790 Default 0.59 Default 0 Existing Wood Clad Oper (Lo/E) HVAC -4 27 Window 35.0 0.770 Default 0.59 Default 90 Existing Wood Clad Door (Lo/E) HVAC -4 28 Window 8.0 0.710 Default 0.60 Default 90 Existing Wood Clad Fix (Lo/E) HVAC -4 29 Window 5.0 0.790 Default 0.59 Default 90 Existing Wood Clad Oper (Lo/E) HVAC -4 30 Window 5.0 0.790 Default 0.59 Default 90 Existing Wood Clad Oper (Lo/E) HVAC -4 31 Window 12.5 0.790 Default 0.59 Default 180 Existing Wood Clad Oper (Lo/E) HVAC -4 32 Window 25.0 0.790 Default 0.59 Default 270 Existing Wood Clad Oper (Lo/E) HVAC -4 (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Len H t LExt RExt Dist Len Ri ht Fin H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 9.0 6.5 1.0 0.1 1.0 1.0 20 Bug Screen 0.76 8.0 5.2 1.0 0.1 1.0 1.0 21 Bug Screen 0.76 8.01 4.5 1.01 0.1 1.01 1.0 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 JBug Screen 0.76 32 JBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2012-08-20714:41:01 1D: Page 8 of 31 ' ' I z lei Project Name Frana Remodel Building Type 0 Single Family 0 Addition Alore 13 Multi Family 10 Existing+ Addition/Altera ion OPAQUE am F-111-11 Joint Appe-idix 4 Location/Comments FENESTRATION SURFACE DETAILS Wood Clad Door (LoAE) -1. . . .. - .- .. CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Frana Remodel Building Type © Single Family ❑ Addition Alor a ❑ Multi Family ® Existing+ AdJition/Alteration Date 1812012012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing__Altered Removed Volume Year Built HVAC -1 HVAC -1 1,110 12,099 2005 HVAC -2 HVAC -2 1,927 23,895 2005 Addition 150 1,500 HVAC -3 HVAC -3 400 4,000 2005 HVAC -4 HVAC -4 680 6,120 2005 Totals 150 4,1171 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC -1 1 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback Existing HVAC -2 2 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback Existing HVAC -3 1 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback Existing HVAC -4 1 Central Furnace 78% AFUE S lit Air Conditioner 9.7 SEER Setback Existing .HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC -1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing HVAC -2 Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing HVAC -3 Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing HVAC -4 Ducted Ducted Attic, Ceiling Ins, vented 4.21 ❑ 1 Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal. 2 Small Gas Kitchen Pipe Ins 34,000 50 0.57 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 a c Q — System Name Pipe Length Pipe Diameter Insul. Thick. aty. HP Plenum Outside Buried EnergyPro 5.1 by EnefgySoft User Number: 3665 RunCode: 2012-08-20714:41:01 ID: Pae 10 of 31 MANDATORY MEASURES SUMMARY:. Residential Pae 1 of 3 MF-1 R Project Name Frana Remodel Date 8/20/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Sclar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. 150(a): Minimum R-19 insulation in wood-frame ceiling ore uivalent U-factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. 150(c): Minimum R-13 insulation in wood-frame wall orequivalent U-factor. *§1 50d : Minimum R-13 insulation in raised wood-frame floor orequivalent U-factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight-fitting damper and or a combustion-air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water-heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water-heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoff User Number 3665 RunCode: 2012-08-20T14:41:01 ID: Page 11 of 31 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Frana Remodel 1812012012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to F_ minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-cosure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 1 50 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipmerx maintenance, and wind. Cellular foam insulation shall be protected as above or painted with.a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilatior and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools -shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable re ui; ements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling urits larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number. 3665 RunCode: 2012-08-20T14:41:01 ID: Page 12 of 31 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Frana Remodel 8/20/2012 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not •equired to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luniunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed wish a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch tf at disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time a clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always or EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the Calitornia Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR.not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site -shall compli with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buiHings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of '119. EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2012-08-20714:41:01 ID: Page 13 of 31 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Frana Remodel Date 8/20/2012 System Name HVAC-1 Floor Area 1,110 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 880 Return Vented Lighting Return Air Ducts Return Fan Ventilation 67 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING Sensible 20,031 0 1,699 01 2,353 0 1,699 1 25,781 PEAK COIL HTG. PEAK Heating System Latent CEM Sensible Output per System 80,000 984 604 22,288 Total Output Btuh 80,000 Output Btuh/s ft 72.1 1,584 Cooling System 0 Output per System 60,000 1,311 67 3,066 Total Output (Btuh) 60,000 1 2,296 0 Total Output (Tons) 5.0 1,584 Total Output Btuh/s ft 54.1 Total Output s ft/Ton 222.0 28,521 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Existing Heat/Cool System (5 Ton) 51,275 867 80,000 Airflow cfm/s ft 1.80 Airflow cfm/Ton 400.0 80,000 Jan 1 AM Outside Air % 3.3 % Total Adjusted System Output 51,275 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 867 Aug 3 PM Outside Air cfm/s ft 0.06 Note: values ,above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatin Peak) 26 °F . Outside Air Ar 67 cfm 69 OF 68 OF 105 OF 105 OF tC+7r+ AHI I Heating Coil Supply Fan 2,000 cfm 105 OF ROOM 70 OF I COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 112/78°F Outside Air Ar 67 cfm 79 / 63 OF 80/64°F 56/54°F 56/54°F U15 O Cooling Coil Supply Fan 2,000 cfm Efl 57 / 55 OF 42.9 °n ROOM I 78 / 63 OF I EnergyPry5.1 by EnergySoft User Number., 3665 RunCode: 2012-08-20714:41:01 ID: Page 14 of 31 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Frana Remodel Date 8/20/2012 System Name HVAC -2 Floor Area 2,077 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 1,244 Return Vented Lighting Return Air Ducts Return Fan Ventilation 116 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 60,000 26,549 1,910 648 29,936 Total Output Btuh 120,000 0 Output Btuh/s ft 57.8 2,251 2,127 Cooling Sys tern 0 0 Output perSystem 36,000 4,102 2,104 116 5,294 Total Output Btuh 72,000 o 4,014 0 Total Output Tons 6.0 2,251 2,127 Total Output Btuh/s ft 34.7 Total Output s ft/Ton 346.2 1 35,153 39,484 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 2,400 Existing Heat/Cool System (3 Ton) 60,735 2,491 120,000 Airflow cfm/s ft 1.16 Airflow cfm/Ton 400.0 120,000 Jan 1 AM Outside Air % 4.8 % Total Adjusted System Output 60,735 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 2,491 Aug 3 PM Outside Air, cfm/s ft 0.06 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 116 cfm 69 OF 67 OF 114 OF 114 OF Heating Coil Supply Fan 2,400 cfm 113 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 116 cfm / 63 OF 80/64°F 56/55°F 56/55°F 9 o Cooling Coil Supply Fan 57 / 56 OF 2,400 cfm � ROOM 44.7 O/c79 78 / 63 OF EnergyPro 5.1 by EnergySoft User Number., 3665 RunCode: 2012-08-20714:41:01 /D: Page 15 of 31 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Frana Remodel Date 8/20/2012 System Name HVAC -3 Floor Area 400 ENGINEERING CHECKS SYSTEM LOAD - Number of Systems 1 COIL CFM Total Room Loads 280 Return Vented Lighting Return Air Ducts Return Fan Ventilation 24 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 48,000 6,471 483 168 9,546 Total Output Btuh 48,000 0 Output Btuh/s ft 120.0 549 678 Cooling System 0 0 Output per System 24,000 852 476 24 1,103 Total Output Btuh 24,000 0 958 0 Total Output Tons 2.0 549 678 Total Output Btuh/s ft 60.0 Total Output s ft/Ton 200.0 8,421 12,006 Air System CFM per System 8001 HVAC EQUIPMENT SELECTION 'Airflow cfm 800 Existing Heat//Cool System (2 Ton) 20,432 377 48,000 Airflow cfm/s ft 2.00 Airflow cfm/Ton 400.0 Outside Air % 3.0% Total Adjusted System Output 20,432 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 377 Aug 3 PM 48,000 Jan 1 AM Outside Air cfm/s ft 0.06 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 24 cfm 69 OF 68 OF 124 OF 124 OF G Heating Coil Supply Fan ° 800 cfm 123 F ROOD J1 70 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 112/78°F Outside Air 24 cfm 79 / 63 OF 80/63°F 56/54°F 56/54°F � O Cooling Coil Supply Fan 56 / 55 OF 800 cfm ,U 42.7% ROOM 78 163 OF EnergyPro 5.1 by EnergySoft User Number- 3665 RunCode: 2012-08-20714:41:01 ID: Page 16 of 31 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Frana Remodel Date 8/20/2012 System Name HVAC -4 Floor Area 680 ENGINEERING CHECKS SYSTEM LOAD Number_ of Systems 1 COIL CFM Total Room Loads 736 Return Vented Lighting Return Air Ducts Return Fan Ventilation 41 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 60,000 16,313 680 313 14,601. Total Output Btuh 60,000 0 Output Btuh/s ft 88.2 1,383 1,037 Cooling System o 0 Output per System 36,000 1,429 782 41 1,875 Total Output Btuh 36,000 0 1,462 0 Total Output Tons 3.0 1,383 1,037 Total Output Btuh/s ft 52.9 Total Output s ftrron 226.7 20,5091 18,550 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Existing Heat/Cool System (3 Ton) 30,779 637 60,000 Airflow cfm/s ft 1.76 Airflow cfm/Ton 400.0 Outside Air % 3.4% Total Adjusted System Output 30,779 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 637 Aug 3 PM 60,000 Outside Air cfm/s ft 0.06 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 41 cfm 69 OF 68 OF 115 OF 115 OF f Cil � Heating Coil Supply Fan 1,200 cfm 114 OF ROOM JE 70 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air -4. 41 cfm 79 / 63 OF 80/64°F. 56/55°F 56/55°F ET Cooling Coil Supply Fan 57 ! 55 OF 1,200 cfm i 143.4% ! ROOM j r) I — 78 /„663 OF I EnergyPro 5.1 by EnergySoft User Number.' 3665 RunCode: 2012-08-20714:41:01 ID: Page 17 of 31 ROOM LOAD SUMMARY Project Name Date Frana Remodel 8/20/2012 System Name Floor Area HVAC -1 1,110 ;ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLIN3 PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM Sensible I Latent CFM I Sensible I Latent CFM I Sensible HVAC -1 HVAC -1 1 1, 880 20,0311 984 880 20, 0a 1 1 984 6041 22,2'88 PAGE TOTAL TOTAL* 0 880 20,031 984 604 22,288 880 20,031 984 604 22,288 * Total includes ventilation load for zonal systems. Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2012-08-20T14:41:01 ID: Pae 18 of 31 ROOM LOAD SUMMARY Project Name Date Frana Remodel 8/20/2012. HVAC -2 26,549 1,910 648 29,936 2,077 ROOM LOAD SUMMARY 648 29,936 ROOM COOLING PEAK COIL COOLIN3 PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible HVAC -2 HVAC -2 1 1,004 22,036 1,761 1,004 22,0-26 1,761 557 25,537 Addition 1 241 4,513 149 .241 4,5A3 149 92 4,399 PAGE TOTAL TOTAL * 1,244 26,549 1,910 648 29,936 1,2441 26,5491 1,9101 648 29,936 * Total includes ventilation load for zonal systems. EnergyPro 5.1 by Ener Soft User Number: 3665 RunCode: 2012-08-20714:41:01 /D: Pae 19 of 31 ROOM LOAD SUMMARY Project Name Date Frana Remodel 8/20/2012 System Name Floor Area HVAC -3 400 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible I Latent CFM I Sensible Latent CFM I Sensible HVAC -3 HVAC -3 1 280 6,4711 483 2801 6,471 483 1681 9,546 PAGE TOTAL TOTAL` 280 6,4 '1 483 168 9,546 280 6,4'1 1 483 168 9,546 ' Total includes ventilation load for zonal systems. Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2012-08-20T14:41:01 /D: Page 20 of 31 ROOM LOAD SUMMARY Project Name Date Frana Remodel 8/20/2012 System Name Floor Area HVAC -4 680 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLINa PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible Latent CFM I Sensible HVAC -4 . HVAC -4 1 1 7361 16,313 680 7361 16,37,31 680 3131 14,601 PAGE TOTAL TOTAL " I ' Total includes ventilation 736 16,3'3 680 313 14,601 736 16,3-3 680 313 14,601 EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2012-08-20T14:41:01 /D: Pacie 21 of 311 ROOM HEATING PEAK LOADS Project Name Frana Remodel Date 8/20/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name HVAC -1 Floor Area 1,110.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value 1,110.0 X 0.0490 1,181.3 X 0.1020 155.0 X 0.7900 8.8 X 0.7100 50.0 X 0.7700 perim = 130.0 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to another room X 1,110 X 10.90 X 0.324 Area Ceiling Height ACH X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X A7 *F = = = = = = = - = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-19 Roof 44 2,393 Existing Wall 44 5,301 Wood Clad Oper (Lo/E) 44 5,388 Wood Clad Fix (Lo/E) 44 273 Wood Clad Door (Lo/E) 44 1,694 Slab -On -Grade 44 4,176 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction Page Total /60] X AT 19,225 = 3,063 TOTAL HOURLY HEAT LOSS FOR ROOM 22,288 EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2012-08-20T14:41:01 ID: Page 22 of 31 ROOM HEATING PEAK LOADS Project Name Frana Remodel Date 8/20/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name HVAC -2 Floor Area 1,927.0 ftz Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value 1,927.0 X 0.0490 1,245.7 X 0.1020 11.3 X 0.7900 27.0 X 0.7100 20.0 X 0.7700 80.0 X 0.4700 perim = 215.0 X 0.7300 X X X X X X X X X °X X X X X X X X X X X X X X X through an interior surface to another room X 1,927 X 12.40 X 0.285 Area Ceiling Height ACH X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 07 *F Btu/hr = 4,155 = 5,591 _ 393 = 843 _ 678 = 1,654 = 6,906 — _ _ = = = = = = _ = = = = = = = = = = =� _ =I = 20,219 44 = 5,318 R-19 Roof 44 Existing Wall 44 Wood Clad Oper (Lo/E) 44 Wood Clad Fix (Lo/E) 44 Wood Clad Door (Lo/E) 44 Wood Clad SGD (Lo/E) 44 Slab -On -Grade 44 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction Page Total / 60 7] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 25,537 EnergyPro 5.1 by EnergySoft User Number.- 3665 RunCode: 2012-08-20714:41:01 ID: Page 23 of 31 ROOM HEATING PEAK LOADS Project Name Frana Remodel Date 8/20/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Addition Floor Area 150.0 ft? Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value A7 *F Btu/hr c 164 = 382 = 1,695 = 1,034 = 736 = = = = = - = = = = = = = = = = =� = = = = = = = = 4,011 42 = 388 R-38 Roof 150.0 0.0260 X X 42 R-21 Wall 131.9 0.0690 42 Iron Dr (Low/E-SB60) 58.5 0.6900 X X 42 Wood Clad (Lo/E-240) 74.6 0.3300 42 Slab-On-Grade perim = 24.0 0.7300 X X X 42 X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 150 X Area another room 10.00 X 0.347 Height ACH Page Total /60] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 4,399 EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2012-08-20T14:41:01 ID: Page 24 of 31 ROOM HEATING PEAK LOADS Project Name Frana Remodel Date 8/20/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name HVAC -3 Floor Area 400.0 ftZ Indoor Dry Bulb Temperature 70 OF Time.of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value 400.0 X 0.0490 X 479.7 X 0.1020 X 46.3 X 0.7900 X 5.0 X 0.7100 X perim = 114.0 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to another room X 400 X 10.00 X 0.354 Area Ceiling Height ACH AT *F 44 = 44 = 44 = 44 = 44 = = = = = = = = = = = = = = = = = = = = = = = = Page Total /60] X 44 AT Btu/hr R-19 Roof 862 Existing Wall 2,153 Wood Clad Oper (Lo/E) 1,609 Wood Clad Fix (Lo/E) 156 Slab -On -Grade 3,662 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction 8,443 = 1,104 TOTAL HOURLY HEAT LOSS FOR ROOM 9,546 EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2012-08-20714:41:01 ID: Page 25 of 31 ROOM HEATING PEAK LOADS Project Name Frana Remodel Date 8/20/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name HVAC-4 Floor Area 680.0 ft2 Indoor Dry Bulb Tem erature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U-Value X -0.0490 X 0.1020 X 0.7900 X 0.7700 X 0.7100 X 0.0460 X X X X X X X X X X X X X X X X X X X X X X X X X to another room 9.00 X 0.393 Ceiling Height ACH X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X A. *F Btu/hr = 1,466 = 5,479 = 1,781 = 2,372 = 250 = 1,376 = = 12,724 44 = 1,876 R-19 Roof 680.0 44 Existing Wall 1,220.8 44 Wood Clad Oper (Lo/E) 51.3 44 Wood Clad Door (Lo/E) 70.0 44 Wood Clad Fix (Lo/E) 8.0 44 R-13 Floor 680.0 44 Items shown with an asterisk (`) denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 680 X Area Page Total / 60 � X AT TOTAL HOURLY HEAT LOSS FOR ROOM 14,601 EnergyPro 5.1 by EnergySoft User Number 3665 RunCode: 2012-08-20T14:41:01 /D: Page 26 of 31 RESIDENTIAL ROOM COOLING LOAD SUMMARY Frana Remodel ROOM INFORMATION Room Name Floor Area Indoor Dry Bulb Tem Opaque Surfaces R-19 Roof Existing Wall Existing Wall Existing Wall Existino Wall DESIGN CONDITIONS HVAC -1 Outdoor Dry Bulb Temperature 1,110.0 ft2 Outdoor Wet Bulb Temperature lure 78 OF Outdoor Dailv Ranqe: Orientation (E) Date 8/20/2012 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,110.0 0.0490 56.0 690.8 0.1020 23.0 184.5 0.1020 33.0 166.0 0.1020 26.0 140.0 0.1020 33.0 37.7 12.5 37.7 0.0 37.7 12.5 37.7 0.0 36.5 5.0 36.5 0.0 37.7 37.5 Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration CsmntWdw (119) FxdGlsWdw (120) CsmntWdw (121) CsmntWdw (122) CsmntWdw (123) FxdGlsWdw (124) CsmntWdw (125) FrnchDr (117) CsmntWdw (118) Orientation (N) (N) (N) (N) (N) (N) (E) (S) (VIO Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 37.7 20.o 37.7 0.0 36.5 3.8 36.5 0.0 37.7 12.5 37.7 0.0 37.7 12.5 37.7 0.0 37.7 12.5 37.7 0.0 36.5 5.0 36.5 0.0 37.7 37.5 72.7 0.0 37.3 50.0 37.4 0.0 37.7 60.J 72.7 Page Total 112 OF 78 OF 34 OF Btu/hr 3,046 1,620 621 440 471, 6,199 Btu/hr 754 137 471 471 471 182 2,727 1,872 4, 363 11,448 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. _ Equipment 0.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 X 0.87 X 68.73 X Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 200311 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.87 X 68.73 X 0.00276 = 784 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM I RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Frana Remodel 8/20/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name HVAC -2 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,927.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF, Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-19 Roof (N) 1,927.0 X 0.0490 X 56.0 = 5,288 Existing Wall (N) 20.0 X 0.1020 X 23.0 = 47 Existing Wall (E) 483.0 X 0.1020 X 33.0 = 1,626 Existing Wall (S) 356.7 X 0.1020 X 26.0 = 946 Existing Wall (Vtq 386.0 X 0.1020 X 33.0 = 1,299 X X = X X - X X = X X = Page Total 9,206 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr CsmntWdw (106) (S) 0.0 X 37.7 + 11.' X 37.8 = 428 FxdGlsWdw (112) (S) 0.0 X 36.5 + 9.0 X . 36.6 = 329 FmchDr(1.11) (IM 0.0 X 37.3 + 20.0 X 723 = 1,446 S1dgGIsDr (115) (IM 0.0 X 22.8 + 80.6 X 44.1 = 3,531 FxdGlsWdw (126) (W) 0.0 X 36.5 + 6.6 X 72.1 = 433 FxdGlsWdw (127) (W) 0.0 X 36.5 + 6.n X 72.1 = 433 FxdGlsWdw(128) (149 0.0 X 36.5 +6.0 X 721 = 433 X + X - X + X - Page Total 7,032 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/ooc. = 460 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 119.32 X 34 = 3,738 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,036 Latent Gain Btu/hr Occupants 2.0 Occupants X 200 Btuh/occ. = 400 Infiltration: 4,771 X 0.87 X 119.32 X 0.00276 = 11361 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,761 Ener Pro 5.1 by Ener Soft User Number 3665 RunCode: 2012-08-20T14:41:01 ID: Page 28 of 31 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Frana Remodel- 8/20/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Addition Outdoor Dry Bulb Temperature 112 OF Floor Area 150.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof (N) 150.0 X 0.0260 X 56.0 = 218 R-21 Wall (E) 40.5 X 0.0690 X 33.0 = 92 R-21 Wall (S) 41.7 X 0.0690 X 26.0 = 75 R-21 Wall (lM 49.7 X 0.0690 X 33.0 = 113 X X = X X = X X = X X = X X = Page Total 499 Items shown with an asterisk (*).denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr EntryDr(1) (E) 4.5 X 22.7 + 54.0 X 37.0 = 2,097 FxdGIsWdw (A) (S) 21.6 X 15.5 + 19.: X 15.6 = 641 FxdGlsWdw (8) (Vl/) 2.9 X 15.5 + 30.4 X 29.8 = 949 X + X - X + X - X + X - X + X - X + X - X + X - Page Total 3,688 Internal Gain Btu/hr Occupants 0.0 Occupants X 230 Btuh/occ. = 0 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.89 X 9.29 X 37 = 326 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 4,513 Latent Gain Btu/hr Occupants 0.0 Occupants X 200 Btuh/o=. = 0 Infiltration: 4,771 X 0.89 X 9.29 X 0.00376 = 149 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 149 EnerqvPro 5.1 by Ener Soft User Number 3665 RunCode: 2012-08-20T14:41:01 ID: Page 29 of 31 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Frana Remodel 8/20/2012 ROOM INFORMATION DESIGN CONDITIONS - Room Name HVAC -3 Outdoor Dry Bulb Temperature 0 112 F Floor Area 400.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 °F Outdoor Daily Range: 34 OF Opaque Surfaces Orientation. Area . U -Factor CLTD' Btu/hr R-19 Roof (N) 400.0 X 0.0490 X 56.0 = 1,098 Existing Wall (N) 52.0 X 0.1020 X 23.0 = 122 Existing Wall (E) 38.0 X 0.1020 X 33.0 = 128 Existing Wall (S) 244.7 X 0.1020 X 26.0 = 649 Existing Wall ' (W) 145.0 X 0.1020 X 33.0 = 488 X X = X X = X X = X X = Page Total 2,485 Items shown with an.asterisk (') denote conduction through an interior surface to'another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr CsmntWdw (109) (N) ' 0.0 X 37.7 + 5.0 X 37.7 = 188 FxdGlsWdw (107) (S) 0.0 X 36.5 + 5.0 X 36.6 = 183 CsmntWdw (108) (S) 0.0 X 37.7 + 11.3 X 37.8 = 428 CsmntWdw (110) (lM 0.0 X 37.7 + 30.0 X 72.7 = 2,182 X + X - X + X - X + X - X + X - X + X = Page Total 2,981 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.87 X 24.77 X 34 = 776 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,471 Latent Gain Btu/hr Occupants 10 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.87 X 24.77 X 0.00276 = 283 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 483 Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2012-08-20T14:41:01 /D: Page 30 of 31 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Frana Remodel 8/20/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name HVAC -4 Outdoor Dry Bulb Temperature 112 OF Floor Area 680.0 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-19 Roof (N) 680.0 X 0.0490 X 56.0 = 1,866 Existing Wall (N) .352.3 X 0.1020 X 23.0 = 826 Existing Wall (E) 266.0 X 0.1020 X 33.0 = 895 Existing Wall (S) 343.5 X 0.1020 X 26.0 = 911 Existing Wall (lM 259.0 X 0.1020 X 33.0 = 872 R-13 Floor 680.0 X 0.0460 X 19.0 = 594 X X = X X = X X = Page Total 5,965 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr CsmntWdw (201) (N) 0.0 X 37.7 + 3.8 X 37.7 = 141 FmchDr(202) (E) 0.0 X 37.3 + . 35.6 X 72.3 = 2,531 FxdGisWdw (203) (E) 0.0 X 36.5 + 8.0 X 72.1 = 577 CsmntWdw (204) '(E) 0.0 X 37.7 + 5.0 X 72.7 = 364 CsmntWdw (205) (E) 0.0 X 37.7 + 5.0 X 72.7 = 364 CsmntWdw (206) (S) 0.0 X 37.7 + 12.5 X 37.8 = 473 CsmntWdw (207) 1149 0.0 X 37.7 + 25.0 X 72.7 = 1,818 FrnchDr(208) (IM 0.0 X 37.3 + 35.0 X 72.3 = 2,531 X + X - Page Total 8,799 Internal Gain Btu/hr Occupants '1.0 Occupants X 230 Btuh/oac. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.87 X 42.11 X 34 = 11319 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,313 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.87 X 42.11 X 0.00276 = 480 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 680 Ener Pro 5.1 by EnerqvSoft User Number: 3665 RunCode: 2012-08-20714:41:01 ID: Page 31 of 31