BRES2015-018978-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
4 sefv Qa!A&
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number: BRES2015-0189
Property Address: 53749 VIA PISA
APN: 777190011
Application Description: FRANA RESIDENCE / PATIO ENCLOSURE TO LIVING SPACE 230 SF
Property Zoning:
Application Valuation: $50,000.00
Applicant:
G L SCRIVENS CONSTRUCTION INC
P 0 BOX 13302
PALM DESERT, CA 92255
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B License No.: 807645 A
Date: O /.O to 7 Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
( ) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_J I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of•the work for which this permit is issued (Sec. 3097,.Civ. C.).
Lender's Name:
Lender's
Owner:
JACQUELINE -FRANA
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 6/10/2015
6055 LAKE GENEVA DR
18-
a=
RENO, NV 92253
c
z
L
0
Contractor:
S
A
C
G•L SCRIVENS CONSTRU
IN�
P 0 BOX 13302
on
PALM DESERT, CA.922
_O
Z3;
(760)837-9918
Llc. No.: 807645
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one ofthe following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 37001of the Labor Code, for the performance
of the wgck•Pbr which this permit is issued.
V I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the perfornance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number: _
I certify that in the performance of fie work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3'0 he Labor Code, I s all forthwith
comply with those provisions.
Date: !� l d Applicant:
WARNING: FAILURE TO SECURE WORKERS' CONI ENS N COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,0013). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this_ application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the Zity of La Quinta, its officers, agents, and
employees for any act or omission related to tF a work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this appliotion becomes null and void if work is
not commenced within 180 days from date of Cssuance of such permit, or cessation of
work for 180 days will subject permit to cancel.ation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this cityto/Rter upon the�llbove-
mentioned property for inspection purposes. Y
Date:O���� ignature (Applicant or Agent)
FINANCIAL INFORMATION
DESCRIPTION
ACCOUNT
QTY AMOUNT
1 PAID
PAID DATE
HOURLY PLAN CHECK - YES
101-0000-42600
1.75 $122.50
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forBLDG CITY STAFF - PER HOUR: $122.50 $0.00
- DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$2.00
$0.00
PAID BY
METHOD
RECEIPT #
= CHECK #
'CLTD BY
Total Paid forBUILDING STANDARDS ADMINISTRATION BSA: $2.00 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$145.03
$0.00
PAID BY`
METHOD
RECEIPT #
CHECK #
CLTD BY
.DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$47.86
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forELECTRICAL - NEW CONSTRUCTION: $192.89 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
APPLIANCE REPAIR/ALTERATION
101-00.00-42402
0
$12.09
$0.00
PAID BY
METHOD
RECEIPT #
= CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
APPLIANCE REPAIR/ALTERATION PC
101-0000-42600
0
$4.83
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for MECHANICAL: $16.92 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
NEW CONSTRUCTION PERMIT
101-0000-42400.
0
$458.49
$0.00
PAID BY
METHOD
RECEIPT #
- CHECK #
CLTD BY
Total Paid forNEW CONSTRUCTION PERMIT: $458.49 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
NEW CONSTRUCTION PLAN CHECK
101-0000-42600
0
$828.66
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forNEW CONSTRUCTION PLAN CHECK: $828.66 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
= PAID
PAID DATE
GAS SYSTEM, 1-4 OUTLETS
101-0000-42401 1
0
$12.09
$0.00
y M., W'1-
- I
-,
'PPAID'-'B
ETHODf; A e
B il"M gg'R
K� 'N
=17i�'/-E� 5. t
P41, #
1
4,
-*-."Acc R3
`QTY
,N) -DESCRIKTIOW
t
iT.s
AMOUNT
TE
GAS SYSTEM, 1-4 OUTLETS PC
101-0000-42600
0
$24.17
$0.00
J'
RECEIPT
eavtl,
Total Paid for PLUMBING FEES: $36.26 $0.00
up
ACCOUNT
'p'qN
z.
`--IIAMOUN
MILE W;
REMODEL, EA ADDITIONAL 500 SF
101-0000-42400
0
$21.75
$0.00
d4R
:
T;'
METHOD K'CLTD
T iW�
T,
BY
NE
&1W K
R, B1t';N1i' A CO U N T—
I "N
2 ma
e4 seug"
'�'-PAIWDAW'
.'x- W, "IR 5
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42600..
0
$17.40
$0.00
`METHOD.i:K, 'K
PUS
W
ACCOUNTS
AMI
2;'�!,�z` PAIM-t
�PAIDDATE;
REIVIODEL-, FIRST 100 SF
0
$49.31
$6.00
i-�'CLTDZYK
yu
E R
l) SC IPTION"
ACCOUNT,
20�
QTY
AMOUNTSs "'�
T."
t
REMODEL, FIRST 500 SF PC
101-0000-42600
0✓
$134.88
$0.00
�jl PAID BY
Um 0,
I
.;9 3j14{YjufTD-13y'101,
NY V
%METHODS w!
W,
-��RECEIPT,
r W.
IECK4,1U,%
61
I
—7
Total Paid forREMODEL: $223.34 $0.00
DESCRIPTIOWt�
COUNT
AMOUNT,
PAID
tp
SMI - RESIDENTIAL
..101-0000-20308
0
$6.50
$0.00
gi
METHOD'1'0"'�
R ft I'OT #1
-�&HEC
-�-,QT ,BY—
L j'�
M gg
H
I i� %
Total Paid forSTRONG MOTION INSTRUMENTATION SMI:' $6.50 $0.00
TOTALS: $1,887.56 $0.00'_
Description: FRANA RESIDENCE / PATIO ENCLOSURE TO LIVING SPACE 230 SF
Type: BUILDING, RESIDENTIAL
Subtype: REMODEL Status: APPROVED
Applied: 5/11/2015 MFA
Approved: 6/10/2015 JJO
Parcel No: 777190011 Site Address: 53749 VIA PISA LA QUINTA,CA 92253
Subdivision: TR 29894-2
Block: Lot: 286
Issued:
Lot Sq Ft: 0
Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $50,000.00
Occupancy Type: Construction Type:
Expired:
No. Buildings: 0
No. Stories: 0 No. Unites: 0
Details: CONVERT CABANA TO OFFICE, CONVERT LOFT TO BEDROOM AND ADD BBQ AREA AND PATIO. PER 2013 CRC CODES
ADDITIONAL
CHRONOLOGY.
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE COMPLETION DATE
NOTES
NOTE
JIM JOHNSON
6/5/2015
6/10/2015
PENDING STRUC CORRECTIONS
NO STRUCTURAL CALCS WERE INCLUDED. JAKE NOTIFIED
NOTE
MARY FASANO
5/11/2015
5/11/2015
ANTON AND PLANS ARE SITTING ON KAY'S PROCESSING
DESK.
PLAN CHECK COMMENTS
FROM CONSULTANT
MARY FASANO
6/8/2015
6/8/2015
APPROVED BY YOUNG
RECEIVED
PUBLIC COUNTER VISIT
MARY FASANO
5/20/2015
5/20/2015
CALCS WERE BROUGHT IN BY ANTON. PLAN CHECK NOW
BEING PROCESSED TO YOUNG ENGINEERING.
TELEPHONE CALL
JIM JOHNSON
6/10/2015
6/10/2015
CALLED SCRIVENS CONST. TO INFORM HIM, SCHOOL FEES
AND ASSESSORS SET REQUIRED TO ISSUE.
CONDITIONS
Printed: Wednesday, June 10, 2015 3:17:40 PM 1 of 4
SYSTEMS
FINANCIAL
INFORMATION
R4141
CLTD.
NAME TYPE
NAME
ADDRES51
CITY
STATE
ZIP PHONE FAX EMAIL
APPLICANT
G L SCRIVENS CONSTRUCTION INC
P 0 BOX 13302
PALM DESERT
CA
92255
CONTRACTOR
G L SCRIVENS CONSTRUCTION INC
P 0 BOX 13302
PALM DESERT
CA
92255
OWNER
JACQUELINE FRANA
6055 LAKE GENEVA DR
RENO
NV
92253
FINANCIAL
INFORMATION
CLTD.
DESCRIPTION ACCOUNT QTY AMOUNT
PAID
PAID DATE RECEIPT # CHECK # METHOD PAID BY
BY
BY
HOURLY PLAN CHECK - 101-0000-42600 1.75 $122.50
$0.00
YES
Total Paid forBLDG CITY STAFF - PER HOUR: $122.50 $0.00
BSAS SB1473 FEE
101-0000-20306
0
$2.00
$0.00
Total Paid forBUILDING STANDARDS ADMINISTRATION
$2.00 $0.00
BSA:
RESIDENTIAL, FIRST
101-0000-42403
0
$145.03
$0.00
1,000SF
RESIDENTIAL, FIRST
101-0000-42600
0
$47.86
$0.00
1,000SF, PC
Total Paid for ELECTRICAL -NEW CONSTRUCTION: $192.89 $0.00
APPLIANCE
101-0000-42402
0
$12.09
$0.00
REPAIR/ALTERATION
APPLIANCE
101-0000-42600
0
$4.83
$0.00
REPAIR/ALTERATION Pt
Total Paid for MECHANICAL: $16.92 $0.00
NEW CONSTRUCTION
101-0000-424000
$458.49
$0.00
PERMIT
Total Paid for NEW CONSTRUCTION PERMIT: $458.49 $0.00
Printed: Wednesday, June 10, 201513:17:40 PM 2 of 4 J
SYS TEhAS
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED ] COMPLETED
DATE DATE
RESULT
REMARKS NOTES
FINAL" BLD
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
NEW CONSTRUCTION
101-0000-42600
0
$828.66
$0.00
PLAN CHECK
Total Paid forNEW CONSTRUCTION PLAN CHECK: $828.66 $0.00
GAS SYSTEM, 1-4
101-0000-42401
0
$12.09
$0.00
OUTLETS
GAS SYSTEM, 1-4
101-0000-42600
0
$24.17
$0.00
OUTLETS PC
'
Total Paid for PLUMBING FEES: $36.26 $0.00
REMODEL, EA
101-0000-42400
0
$21.75
$0.00
ADDITIONAL 500 SF
REMODEL, EA
101-0000-42600
0
$17.40
$0.00
ADDITIONAL 500 SF PC
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$0.00
REMODEL, FIRST 500 SF
j 101-0000-426000
$134.88
$0.00
PC
Total Paid for REMODEL: $223.34 $0.00
SMI - RESIDENTIAL,
101-0000-20308
0.
$6.50
$0.00
Total Paid forSTRONG MOTION INSTRUMENTATION SMI $6.50 $0.00
TOTALS:$0.00
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED ] COMPLETED
DATE DATE
RESULT
REMARKS NOTES
FINAL" BLD
PARENT PROJECTS
Printed: Wednesday, June 10, 2015 3:17:40 PM 3 of 4
?SYSTEMS
Permit Details � PERMIT NUMBER
City of La Quinta
BRES2015=01$9
STRUCTURAL . YOUNG 5/20/2015 6/10/2015 6/8/2015 READY FOR APPROVAL
ENGINEERING
NON-STRUCTURAL JJIMJOHNSONJ 5/20/2015 1 6/10/2015 1 6/10/2015 1 APPROVED
BOND INFORMATION
Printed: Wednesday, June 10, 2015 3:17:40 PM 4 of 4EAS
§?
SYSTEMS
ein #
City of La Quinta
Building 8t Safety Division
6
P.O. Box 1504, 78-495 Calle Tampico
��� La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
7�e— . -
g� W
Project Address: 6—S7 V 1
Owner's Name:
A. P. Number: 7 . S1G
Address: S -'g cjc U1.
Legal Description: e5a y?
Contractor: L. S
City, ST, Zip: G/7S4 G
T ele hone:
P 72L
Address: 7 4-5-6,10^q b tzProject
Description:
City, ST, Zip:
ele h one:
TP �
AlU ' Oma,!
612S
State Lic. # : D7,0y
City Lic.
Arch., Engr., Designer:
Address: -S77-- (/l1l,Py`-
City., ST, Zip: 5 f: e
Telephone:
7
�G
on truct i e•
n TY P OecuP an cY:
U
Troject
State Lie. #:
hPa (circle one • New Add'n Repair Demo
Name of Contact Person:
Sq. Ft.:�25O57't--
# Stories: 2
# Units:
Telephone # of Contact Person:
Estimated Value of Project: sQ Oct:) CC
APPLICANT: DO NOT WRITE BELOW THIS LINE
t!
Submittal
Req'd
Rec'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance
Title 24 Cales.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2". Review, ready for corrections/issue
Electrical
Subcontactor List
Called ContactPerson
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees .
Total Permit Tees
kib �- 651 is
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVELONEAMOUNT:
LEVELTWOAMOUNT:
IV ITIGATION AMOUNT:
COMMAND. AMOUNT:
DATE:
RECEIPT:
CHECK #:
INITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: Hid�ea
Owner's Name: Gary Frana
Project Address: 53-749 Via Pisa, LaQuinta
Project Description: Convert Patio to A/C Space
APN: 772-530-011
Tract #:
Type of Development: Residential XX
Total Square Feet of Building Area:
Certification of Applicant/Owners: The person signing certifies
penalty of perjury and further represents that he/she is authorize44
Dated: June 9, 2015 Signature:
Commercial
230
Date: June 9, 2015
Phone No. 760-831-7439
Lot #'s:
Industrial
the above information is correct and makes this statement under
tyon behalf of the owner/developer.
************************************4a** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PR9J`ECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Project Agreement Existing Not Subject to Fee
17620 65995 Approval Prior to 1/1/87 Requirement
Number of Sq.Ft.
Amount per Sq -
Ft -Amount Collected
230
$0.00
$0.00
Building Permit Application Completed: Yes/No
By: Elsa F. Esqueda, Director of Facilities and Maintenance
Certificate issued by: Laurie Howard, Secreta
Note:
Pursuant to AB 181 any room additions or enclosures of 500
sq. ft. or less are exempt from developer fees. Any mobile
homes being relocated within the same school district's
jurisdiction are exempt from developer fees.
Signature:
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
M V:c/nrydocs/devfees/cettilicate of compliance fonn updated 3-2007 11/2010
•
Tf 68 Country iub is Ste. B Paim Reser# GA 92
Ph (FO) 772 :5107 01 17 5-76�U Email in +o@valuengr:com eb www_valuer+gr,cam
Letter of Transmittal
To: City of La Quinta Today's Date: 6-8-15
78-495 Calle Tampico City Due Date: 6-3-15
La Quinta, CA 92253 Project Address: 53749 Via Pisa
Attn: Kay Plan Check #: BRES 2015-0189
Submittal: ® 1st ❑ 4th
❑ 2nd ❑ 55th
❑ 3rd ❑ Other:
We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup
Includes:
# Of Descriptions:
Includes: # Of
Descr ptions:
Copies:
Copies:
®
1 Structural Plans
❑
Revised Structural Plans
®
1 Structural Calculations
❑
Revised Struct. Calcs
❑
Truss Calculations Floor
and Roof
❑
Revised Truss
❑
Soils Report
❑
Revissd Soils Report
®
1 Structural Comment List
❑
Apprcved Structural Plans
❑
Redlined Structural Plans
❑
Apprcved Structural Calcs
❑ '
Redlined Structural Calcs
❑
Apprcved Truss Calcs
❑
Redlined Truss Calcs
❑
Apprcved Soils Report
❑
Redlined Soils Reports
❑
Other.
Comments:
Structural content is approvable.
If you have any questions, please call.
Time = 1.75 HR
This Material Sent for:
❑ Your Files
❑ Your Review
❑ Checking
Other: ❑
BY: Kathryn Samuel
Palm Desert Office: ® (760) 772-510;
Other: ❑Et
® Per Your Request
❑ Approval
❑ At the request of:
CIT Y OF LA, QUINTA
COMMUNITY DEVELOPMENT
Ih_..-
I BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
Frana Residence
Lot 286 The Hideaway
La Quinta, CA 92253
Project Designer:
Stracts Architecture
550 S. Oleander
Palm Springs, CA 92662
(760) 636-8951
Report Prepared by:
Jon Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Palm Desert, CA 92211
(760) 200-4780 C, 1-y
eU Di' QUINT
APP & SAFETY DEP
FOR COR®,/E®
VCTION
DATe 61
J[A/rte ,- __
Job Number:
MAY 11 2015
Date: CITY OF LA QUINTA
4/23/2015 COMMUNITY DEVELOPMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
viol
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Frana Residence Calculation Date/Time: 09:35, Thu, Apr 23, 2015
Calculation Description: Title 24 Analysis
Input File Name: Frana-Stracts-15.xml
CF&F-01
Page 1 of 9
GENERAL INFORMATION
01
Project Name Frana Residence
02 This building incorporates features that require field testing and/orverification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
02
Calculation Description Title 24 Analysis
03
Project Location Lot 286 The Hideaway
ENERGY USE SUMMARY
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version
BEMCmpMgr 2013-3c (710)
08
Climate Zone CZ15
09
Software Version
EnergyPro 6.5
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 315
12
Project Scope Addition and/or Alteration
13 1i
Number of Dwelling Units
1
14
Total Cond. Floor Area (FT2) 4357
15 'tjo
Number of Zones
3
16
Slab Area (FT2) 3677
0.00
Number of Stories
2
18
Addition Cond. Floor Area 240
�1�91,
Natural Gas Available
Yes
20
Addition Slab Area (FT2) 240
.2�1
Glazing Percentage (%)
18.7%
Aw
COMPLIANCE RESULTS t v
01 Building Complies with Computer Performance AtW;
02 This building incorporates features that require field testing and/orverification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04 O!Q®;
06
07
08
Energy Use Standard
(kTDV/ft2-yr) Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating fj12.25
9.51
2.74
22.4%
Space Cooling 287.68
268.82
18.86
6.6%
IAQ Ventilation w 0.00
Water Heating 7.55
0.00
7.55
0.00
0.00
0.0%
U.U%
Photovoltaic Offset —
0.00
0.00
—
Compliance Energy Totaly 307.48
tWC
285.88
21.60
7.0%
.0
Registration Number:
CA Building Energy Efficiency StanbaMs - 2013 Residential Compliance
Registration Date/Time:
Report Version - CFIR-04012015-710
HERS Provider:
Report Generated at: 2015-04-23 09:37:24
CERTIFW OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Frana Residence Calculation Date/Time: 09:35, Thu, Apr 23, 2015
Calculation Description: Title 24 Analysis
Input File Name: Frana-Stracts-15.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
CFIOF-01
Page 2 of 9
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
High Quality Insulation Installation (QII)
Cooling System Verifications:
• — None —
HVAC Distribution System Verifications:
• -- None —
Domestic Hot Water System Verifications:
• — None —
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system. �A►
Reference Energy Use �` Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)* 345.62 . 324.02 1 21.60 6.2%
` Includes calculated Appliances and Miscellaneous Energy Use (AMEU) A ; a#
_v.
BUILDING - FEATURES INFORMATION V
01
02
`03
04
05
06
07
�♦►•�•
Numb"er of Dwelling
Zone Floor Area
Avg. Ceiling
Number of Ventilation
Number of Water
Project Name
Conditioned Floor Area (ft2)
�� Units
Number of Bedrooms
Number of Zones
Cooling Systems
Heating Systems
Frana Residence
4357 r
1
9
3
1
1
V
ZONE INFORMATION _W
01
02
03
04
0S
06
07
�♦►•�•
Zone Floor Area
Avg. Ceiling
Zone Name
Zone Typ Q
HVAC System Name
(ft2)
Height
Water Heating System 1
Water Heating System 2
residence
Condittioned
HVAC1
3437
14
DHW Sys 1
addition
Conckioned
HVAC1
240
14
DHW Sys 1
2nd floor
Conditioned
HVAC1
680
14
1 DHW Sys 1
Registration Number: ,�
CA Building Energy Efficiency Standa ds - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-04012015-710
HERS Provider:
Report Generated at: 2015-04-23 09:37:24
g oueA&Y
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Frana Residence Calculation Date/Time: 09:35, Thu, Apr 23, 2015
Calculation Description: Title 24 Analysis
Input File Name: Frana-Stracts-15.xmi
CFI•RF-01
Page 3 of 9
OPAQUE SURFACES
01
02
03
04
05
06
07
08
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door
Area (ft2)
Tilt
(deg)
Status
Verified
Existing
Condition
NE Wall ex
residence
R-13 Wall
45
Left
2350
116.6
90
Existing
No
SE Wali ex
residence
R-13 Wall
135
Back
2620
253
90
Existing
No
SW Wall ex
residence
R-13 Wall
225
Right
2350
71.3
90
Existing
No
NW Wall ex
residence
R-13 Wall
315
Front
2620
112.1
90
Existing
No
Roof
residence
Defaul: 1978 to present
2757
Existing
No
NE Wall
addition
R-21 Wall (W.21.2x6.16)
45 Left
340
3
90
New
N/A
SE Wall
addition
R-21 Wall (W.21.2x6.16)
135
Back
260
56
90
New
N/A
SW Wall
addition
R-21 Wall (W.21.2x6.16)
225%
Right
340
88
90
New
N/A
NW Wall
addition
R-21 Wall (W.21.2x6.16)
31
Front
80
90
New
N/A
Roof 2
addition
R-38 Roof Attic
240
New
N/A
NE Wall ex 2
2nd floor
R-13 Wall cj 45
Left
600
12.5
90
Existing
No
SE Wall ex 2
2nd floor
R-13 Wall
135
Back
570
65
90
Existing
No
SW Wall ex 2
2nd floor
R-13 Wail v
225
Right
600
3.8
90
Existing
No
NW Wall ex 2
2nd floor
R-13 Wall `�
315
Front
520
58
90
Existing
No
Roof 3
2nd floor
Defaul: 1978 tnresent1
680
Existing
No
n
ATTIC �v
01
02
03
04
05
06
07
08
09
10
Radiant
Statu
Verified Existing
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Barrier
Cool Roof
s
Condition
Ex9 ti
Attic residence
Attic Roofresidence�
Ventilated
3
0.1
0.85
No
No
No
Attic addition
Attic Roofaddition*v
Ventilated
3
0.1
0.85
No
No
New
No
Eng t�
Attic 2nd floor
Attic Roof2nd��r
Ventilated
3
0.1
0.85
No
No
No
�O!
Registration Number:
CA Building Energy Efficiency Stands - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-04012015-710
HERS Provider:
Report Generated at: 2015-04-23 09:37:24
CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE II*OD -
Project Name: Frana Residence Calculation Date/Time: 09:35, Thu, Apr 23, 2015
Calculation Description: Title 24 Analysis
Input File Name: Frana-Stracts-15.xml
CFIIOF-01
Page 4 of 9
WINDOWS
01
02
03
04 06
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Multiplie
Height (ft) r
Area (ft2)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
ex 2.5x4.5
NE Wall ex (Left -45)
-
- 1
11.3
0.71
0.60
Insect Screen (default)
Existing
No
ex 2x2.5
NE Wall ex (Left -45)
-
- 1
5.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 2.5x4.5 2
NE Wall ex (Left -45)
-
- 1
11.3
0.71
0.60
Insect Screen (default)
Existing
No
ex 2x4.5
NE Wall ex (Left -45)
-
- 1
9.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 5x8
NE Wall ex (Left -45)
-
- 1
'*40.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 5x8 2
NE Wall ex (Left -45)
-
-- 1 40.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 5x6
SE Wall ex (Back -135)
--
- ,1
30.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 5x6 2
SE Wall ex (Back -135)
-
- �1r1
30.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 6x8
SE Wall ex (Back -135)
-
- 1
48.0
0.71
0.60
Insect Screen (default)
Existing
No
ex6x4.5
SE Wall ex (Back -135)
-
- 1
27.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 5x8 3
SE Wall ex (Back -135)
-
1
40.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 2x3
SE Wall ex (Back -135)
-
1
6.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 2x3 2
SE Wall ex (Back -135)
-
G `- 1
6.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 2x3 3
SE Wall ex (Back -135)
- a - 1
6.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 7.5x8
SE Wall ex (Back -135)
- *
- 1
60.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 2x2.5 2
SW Wall ex (Right -225)
M�
- 1
5.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 2.5x8
SW Wall ex (Right -225)
fir-
1
20.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 1.5x2.5
SW Wall ex (Right -225)
�`�-
- 1
3.8
0.71
0.60
Insect Screen (default)
Existing
No
ex 2.5x5
SW Wall ex (Right -225) j v -
- 1
12.5
0.71
0.60
Insect Screen (default)
Existing
No
ex 2.5x5 2
SW Wall ex (Right -225), ,
-
- 1
12.5
0.71
0.60
Insect Screen (default)
Existing
No
ex 2.5x5 3
SW Wall ex (Right -225)
-
- 1
12.5
0.71
0.60
Insect Screen (default)
Existing
No
ex 2x2.5 3
SW Wall ex (Right -2,,220*
-
- 1
5.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 7.5x8 2
NW Wall ex (Fron,:0, 15)
-
- 1
60.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 4x8
NW Wall ex (Front 315)
-
- 1
32.0
0.71
0.60
Insect Screen (default)
Existing
No
new 7x8.46.24
SE Wal,(B'a,&135)
-
-- 1
56.0
0.46
0.24
Insect Screen (default)
New
N/A
new 8x8.46.24
SW Wall;(Right-225)
-
-- 1
64.0
0.46
0.24
Insect Screen (default)
New
N/A
new 3x8.46.24
SWZOS11 (Right -225)
-
- 1
24.0
0.46
0.24
Insect Screen (default)
New
N/A
ex 2.5x5 4
KN(t "Nall ex 2 (Left -45)
-
- 1
12.5
0.71
0.60
Insect Screen (default)
Existing
No
ex 5x5
AFS'tWall ex 2 (Back -135)
-
- 1
25.0
0.71
0.60
Insect Screen (default)
Existing
No
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Stands - 2013 Residential Compliance Report Version - CF1R-04012015-710
HERS Provider:
Report Generated at: 2015-04-23 09:37:24
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Frana Residence Calculation Date/Time: 09:35, Thu, Apr 23, 2015
Calculation Description: Title 24 Analysis
Input File Name: Frana-Stracts-15.xm1
CFWF-01
Page 5 of 9
ex 5x8 4
SE Wall ex 2 (Back -135) —
— 1
40.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 12.5x2.5
SW Wall ex 2 (Right -225) —
— 1
3.8
0.71
0.60
Insect Screen (default)
Existing
No
ex 5x8 5
NW Wall ex 2 (Front -315) —
— 1
40.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 2x4
NW Wall ex 2 (Front -315) —
— 1
8.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 2x2.5 4
NW Wall ex 2 (Front -315) —
— 1
5.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 2x2.5 5
NW Wall ex 2 (Front -315) —
— 1
5.0
0.71
0.60
Insect Screen (default)
Existing
No
DOORS
01 02 03,0., 04 05 06
',-
Name Side of Building Area (ftZ) U -factor Status Verified Existing Condition
Door NW Wall ex i 0.1 0.50 Existing No
C71
OPAQUE SURFACE CONSTRUCTIONS '�V
Z14111;
01
02
03
04 A
05
06
07
V
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
d
Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Cho of Roof Truss @ 24
Roof Deck. Wood Siding/sheathing/decking
Attic Roofresidence
Attic Roofs
Wood Framed Ceiling
..� in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below�►•�
Cavity/Frame: R-9.1 /2x4
Defaul: 1978 to present
attic)
Wood Framed Ceiling
��/ 2x4 @ 16 in. O.C.
R11
0.083
Over Floor Joists: R-1.9 insul.
l!v
Inside Finish: Gypsum Board
`>
Cavity/Frame: R -13/2x4
Exterior Finish: Wood
R-13 Wall
Exterior Walls
Wood Framed W�alli
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
`r-
O
• Cavity/Frame: no insul. /2x4 Top Chrd
*
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Roofing. Roof Shingle)
Attic Roofaddition
Attic Roofs
Wood FrariCeiling
in. O.C.
none
0.644
Light (Asphalt
O
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)Wo�Framed
Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
Inside Finish: Gypsum Board
• Cavity/Frame: R-21 /2x6
'
Exterior Finish: Wood
R-21 Wall (,21.2x6.16)
Exterior Walls%
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
S`
Cavity/Frame: no insul. /2x4 Top Chrd
'0 0
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof2nd floor
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
.y
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-04012015-710 Report Generated at: 2015-04-23 09:37:24
CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOOD
Project Name: Frana Residence Calculation Date/Time: 09:35, Thu, Apr 23, 2015
Calculation Description: Title 24 Analysis
Input File Name: Frana-Stracts-15.xml
CF10-F-01
Page 6 of 9
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Covered Slab
residence
3437
316
None
0.8
No
Existing
No
Covered Slab 2
addition
240
47
None
0.8
No
New
No
BUILDING ENVELOPE - HERS VERIFICATION
%_ 1,
01
02 '-IV 03 04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation,� > Building Envelope Air Leakage ACH @ 50 Pa
Required
Not Required �i Not Required
Y=�
WATER HEATING SYSTEMS 00
01
02
03 tj
04
05
06
07
08
®
Tank Volume
Energy Factor or
Solar
Tank Exterior
Standby Loss
Name
Heater Element Type
4an7c Type(gal)
Point -of Use
Number of
Fraction
Insulation R -value
Verified Existing
Name
System Type
Distribution Type
Water Heater
Heaters
N
Status
Condition
DHW Sys 1
DHW
Pipe Insulation, All Ling4,V
DHW Heater 1
2
Annual
Existing
No
A
WATER HEATERS
01
02
003V
04
05
06
07
08
�`�"
Tank Volume
Energy Factor or
Recirculation with
Tank Exterior
Standby Loss
Name
Heater Element Type
4an7c Type(gal)
Point -of Use
Efficiency
Input Rating
Insulation R -value
(Fraction)
DHW Heater 1
Natural Gas
4Smiil Storage
50
0.61 EF
40000-Btu/hr
0
0
O
WATER HEATING - HERS VERIFICATION
01
02 '�
03
04
05
06
07
Recirculation with
Recirculation with
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Manual Control
Sensor Control
DHW Sys 1
n/a&
n/a
n/a
n/a
n/a
n/a
•�
Registration Number: 1%, Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standdaa"Fds - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-23 09:37:24
CERTIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IOD
Project ame. Frana Residence Ca culation Date/Time: 09:35, Thu, Apr 23, 2015
Calculation Description: Title 24 Analysis
Input File Name: Frana-Stracts-15.xm1
CFPRF-01
Page 7 of 9
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
10
Multi -speed
Heating System
Cooling System
System Type
EER 40V6 SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
10.42V
12
Distribution
Fan
Floor Area
Location
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
HVAC1
Other Heating and
Heating
Yes
Cooling
Yes
Air Distribution
HVAC Fan
4357
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type a� Efficiency
Heating Component 1 CntrlFurnace - Fuel -fire reentral furnace 80 AFUE
.71'
HVAC - COOLING SYSTEMS �r
01
02
03 �`-�� 04
06
06
07
07
08
Efficiency
10
Multi -speed
Name
System Type
EER 40V6 SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
10.42V
12
No
No
N/A
Location
system
Status
Condition
Verification
Air Distribution
Ducts located in attic
v
HVAC - DISTRIBUTION SYSTEMS
01
02
03
044f�`i'
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
k value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
4.2
Attic
Attic
None
Existing
No
N/A
System 1
specified)
s w
IAQ (indoor Air Quality) FANS 4lobf
01 " 02
03 04 05
IAQ an Type IAQ Recovery Effectiveness(%) HERS Verification
Name IAQ CFM
SFam IAQVentRpt'`'� 0
Default 0 Not Required
Ci
COOLING VENTILATION
01
02 03 04
Name
Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans
WH Fan 1
`� 61 0.52459 1
�O°7
Registration Number: ,�� Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Stanrda ds - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-23 09:37:24
CERTIF10 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE D
Project Name: Frana Residence Calculation Date/Time: 09:35, Thu, Apr 23, 2015
Calculation Description: Title 24 Analysis Input File Name: Fran a-Stracts-1 5. xm I
�0
®fir
.40
.��
Registration Number: ,��
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-04012015-710
CF1�F-01
Page 8 of 9
HERS Provider:
Report Generated at: 2015-04-23 09:37:24
CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE �OD
Project Name: Frana Residence Calculation Date/Time: 09:35, Thu, Apr 23, 2015
Calculation Description: Title 24 Analysis
Input File Name: Frana-Stracts-15.xml
CF1�F-07
Page9of9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Documentation Author Signature: d. Scott
lJon
Jon Scott
Company:
Signature Date:
Scott Design and Title 24, Inc,
4/23/2015
Address:
CEA/HERS Certification Identification (If applicable):
77-085 Michigan Drive
City/State ip:
Falco Desert, CA 92211
Phone:+
(60) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT%
I certify the following under penalty of perjury, under the laws of the State of California: ���
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility fo�thhe building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Comp it ante are consistent with the information provided on other applicable compliance documents,
YN—
worksheets, calculations, plans and specifications submitted to the enforcement agency- oapproval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Stracts Architecture
Company: v
Date Signed:
Stracts Architecture (�
Address: �r0
License:
550 S. Oleander
City/State/Zip:
Phone:
Palm Springs, CA 92662 ,��
(760) 636-8951
0�
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-04012015-710
HERS Provider:
Report Generated at: 2015-04-23 09:37:24
•
•
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Frana Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
4/23/2015
Project Address
Lot 286 The Hideaway La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,357
Addition
240
# of Units
1
INSULATION
Construction Type
Area
Cavi(ft) Special Features Status
Roof Wood Framed Attic R11 3,437 Existing
Wall Wood Framed R 13 11,538 Existing
Door Opaque Door - no insulation 20 Existing
Slab Unheated Slab -on -Grade - no insulation 3,437 Perim = 316' Existing
Demising Wood Framed R 13 1,035 New
Roof Wood Framed Attic R 38 240 New
Wall Wood Framed R 21 876 New
Slab Unheated Slab -on -Grade - no insulation 240 Perim = 47' New
FENESTRATION I Total Area: 816 Glazing Percentage: 18.7 % New/Altered Average U -Factor: 0.46
Orientation Areaftz U -Fac SHGC Overhang Sidefins Exterior Shades Status
Left (NE) 129.1 0.710
0.60 none none Bug Screen Existing
Rear (SE) 318.0 0.710
0.60 none none Bug Screen Existing
Right (SW) 75.1 0.710
0.60 none none Bug Screen Existing
Front (NVt9 150.0 0.710
0.60 none none Bug Screen Existing
Rear (SE) 56.0 0.460
0.24 none none Bug Screen New
Right (SW) 88.0 0.460
0.24 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
4 Central Furnace 80% AFUE
Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC Ducted
Ducted Attic 4.2
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnerqvPro 6.5 by EnemySoft User Number.- 6712
Run Code: 2015-04-23T09:38:06 ID:
Pae 12 of 26
2013 Low -Rise Residential Mandatory Measures Summary
Ak
4
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
CamDliance aDDroach used. EXCeDtions may annly. Review the resnertive rnde serlinn fnr mnre infnrmntinn
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of § 10-111 a .
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§I 10.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of §I 10.8(1) when the
installation of a cool roof is specified on the CFIR.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ I50.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§150.0(6):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ 150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ I50.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§150.0(g)l:
walls, vented attics and unvented attics with air -permeable insulation.
§ 150.0(g)2:
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ I50.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§I50.0(e)IB:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible operable, and tight -fitting damper or a combustion -air control device.
§I50.0(e)IC:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ I50.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§150.0(h)I:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in§150.Oh2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ I50.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§150.00)IA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150.00)1 B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ I50.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
In
4
2013 Low -Rise Residential Mandatory Measures Summary
§150.00)2C:
Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ I50.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
hinted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ I50.0(n)1:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ I50.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ I50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ ] 50.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 'A inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§ I50.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§I50.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0 m 12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§] 50.0(m)13:
space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§I50.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic
testing,in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)]A:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
4
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ 150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§ ] 50.0(k)I A:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§150.0(k)]B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§150.0(k)IC:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§I50.0(k)ID:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§I50.0(k)]E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § ] 50.0(k).
§ I50.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ I50.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ I50.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k).
§I50.0(k)2F:
Lighting controls comply with applicable requirements of §110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if. it functions as a dimmer
§] 50.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of §130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of §I50.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5 • and all other requirements in ' 150.0(k)2.
§ I50.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in §150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ I50.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ I50.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
0
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§I50.0(k)9B:
following requirements:
i. Shall comply with §I50.0(k)9A; or
ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, 130.4, 140.7 and §141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in 110.9 '130.0 130.2 '130.4, 140.7 and §141.0.
§ I50.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9 130.0, § 130.2, § 130.4, § 140.7 and $141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
'
according to 130.0(c).
§ I50.0(k)1 l:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
' ' ' '
nonresidential garages in 110.9 130.0 130.1 130.4 § 140.6 and ' 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ I 50.0(k) I 2A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of $110.10 b through §110.10(e).
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10 6 through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§I 10.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal ro'ection of the nearest point of the solar zone measured in the vertical plane.
§I 10.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through §110. 10(c)
shall be provided to the occupant.
§ 110.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
0
4
4
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Tana Residence
Date
4/23/2015
System Name
HVAC
Floor Area
4,357
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
4
COIL
CFM
Total ROOM Loads 9,100
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 1,017
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK
Sensible
118,533
0
8,100
01
44,411
0
8,100
179,145
COIL HTG.
Latent CFM
10,861 3,416
16,222 1,017
27,083
PEAK
Heating System
Sensible
Output per System 89,000
125,328
Total Output Btuh 356,000
Output Btuh/s ft 81.7
6,788
Cooling System
0
Output per System 57,800
48,906
Total Output Btuh 231,200
0
Total Output Tons 19.3
6,788
Total Output Btuh/s ft 53.1
Total Output s ft/Ton 226.1
187,808
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
8,000
Existing HVAC
164,821
37,200
356,000
Airflow cfm/s ft
1.84
Airflow cfmrron 415.2
Outside Air %
12.7%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK
164,821
37,200 356,000
Aug 3 PM Jan 1 AM
Outside Air cfm/s ft 0.23
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF 65 OF
Outside Air
1,017 cfm Supply Fan
8,000 cfm
71 OF
65 OF 107 OF
Heating Coil
-�
106 OF
ROOM
72 OF
1
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 76/64°F 76/64°F 57/56°F
Outside Air c
1,017 cfm Supply Fan Cooling Coil
8,000 cfm
71/61°F
60.9%
58 / 56 OF
ROOM 11
70/61°F
Energ Pro 6.5 by Energ Soft User Number., 6712 RunCode: 2015-04-23709:38:06
ID:
Page 17 of 26
•
•
•
ROOM LOAD SUMMARY
Project Name
Frana Residence
Date
4/23/2015
System Name
HVAC
Floor Area
4,357
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING 'EAK
COIL HTG. PEAK
Zone Name Room Name
Mult. CFM Sensible Latent
CFM
Sensible Latent
CFM Sensible
residence altered residence
1 6,935 90,331 8,568
6,935
90,331
8,568
2,636 96,726
addition new addition
1 540 7,032 598
540
7,032
598
237 8,683
2nd floor 2nd floor res
1 1,625 21,171 1,695
1,625
21,171
1,695
543 19,918
1
Total includes ventilation load for zonal systems.
PAGE TOTAL
TOTAL '
9,100
9,100
118, 533 10,8611
118, 53 10,8611
3,416 125,328
3,416 125,328
EnergyPro 6.5 by EnergySoft User Number. 6712
Run Code: 2015-04-23T09:38:06
ID:
Pae 18 of 26
C]
•
•
ROOM HEATING PEAK LOADS
Project Name
Frana Residence
Date
4/23/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name altered residence
Floor Area 3,437.0 f'
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction Area U -Value
Defaul: 1978 to present 2,757.0 X 0.0790
R-13 Wall 9,387.0 X 0.1020
Existing Window 532.9 X 0.7100
Wood Door 20.1 X 0.5000
Slab -On -Grade perim = 316.0 X 0.7300
'R-13 Wall 722.0 X 0.1020
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (•) denote conduction through an interior surface to another room
Infiltration:[ 1.00 X 1.064 X 3,437 X 14.00 X 0.361
Schedule Air Sensible Area Ceiling Height ACH
Fraction
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT OF
Btu/hr
= 10,019
= 44,044
c 17,405
= 462
= 10,611
= 0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
82,541
46 = 14,185
46
46
46
46
46
0
Page Total
/60] X
AT
TOTAL HOURLY HEAT LOSS FOR ROOM 96,726
EnergyPro 6.5 by EnergySoft User Number: 6712 Run Code: 2015-0423709:38:06 ID: Page 19 of 26
•
•
LJ
ROOM HEATING PEAK LOADS
Project Name
Frana Residence
ROOM INFORMATION
Room Name
Floor Area
Indoor Dry Bulb Temperature
Conduction
R-38 Roof Attic
R-21 Wall (W.21.2x6.16)
LowE METAL .46.24
Slab -On -Grade
"R-13 Wall
DESIGN CONDITIONS
new addition Time of Peak
240.0 ft' Outdoor Dry Bulb Temperature
72 OF
Area
240.0
876.0
144.0
perim = 47.0
101.0
U -Value
X
0.0260
X
X
X
0.0690
X
X
0.4600
X
0.7300
X
X
X
X
X
X
0.1020
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (') denote conduction through an interior surface to another room
Infiltration:[ 1.00 X 1.064 X 240 X 14.00 X 0.361
Schedule Air Sensible Area Ceiling Height ACH
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM
AT *F
46
46
46
46
0
Page Tc
/60] XC
Al
4/23/2015
Jan 1 AM
26 OF
Btu/hr
287
2,780
c 3,047
1,578
c 0
'till 7,693
46 0 991
6831
EnergyPro 6.5 by EnergySoft User Number: 6712 Run Code: 2015-04-23T09:38:06 ID: Page 20 of 26
•
C
1
U
ROOM HEATING PEAK LOADS
Project Name
Frana Residence
Date
4/23/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name 2nd floor res
Floor Area 680.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area U -Value
680.0 X 0.0790
2,150.7 X 0.1020
139.3 X 0.7100
212.0 X 0.1020
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
through an interior surface to another room
X 680 X 14.00 X 0.361
Area Ceiling Height ACH
AT °F Btu/hr
X 46 c 2,471
X 46 c 10,091
X 46 = 4,550
X 0 = 0
X
X =
X =
X
X o
X
X =
X =
X
X =
X =
X =
X =
X =
X =
X =
X =
X
X =
X =
X =
X =
X =
X =
X =
X =
X =
Page Total 17,112
/60] X 46 = 2,806
AT
Default 1978 to present
R-13 Wall
Existing Window
'R-13 Wall
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 19,918
EnergyPro 6.5 by EnergySoft User Number: 6712 Run Code: 2015-0423709:38:06 ID: Page 21 of 26
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Frana Residence 1 4/23/2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name altered residence Outdoor Dry Bulb Temperature 112 OF
Floor Area 3,437.0 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranqe: 34 OF
Opaque Surfaces
Defauh. 1978 to present
R-13 Wall
R-13 Wall
R-13 Wall
R-13 Wall
Wood Door
'R-13 Wall
Orientation
(►M
(NE)
(SE)
(SK9
(NW)
(NW)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
Z757.0
0.0790
56.0
2,233.4
0.1020
29.0
2,367.0
0.1020
31.0
2,278.7
0.1020
31.0
2,507.9
0.1020
30.2
20.1
0.5000
30.2
722.0
0.1020
0.0
55.8
0.0
36.5
40.0
55.8
0.0
36.5
30.0
Page Total
Items shown'with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fpnpctratinn
ex 2.5x4.5
ex 2x2.5
ex 2.5x4.5
ex 2x4.5
ex 5x8
ex 5x8
ex 5x6
ex 5x6
ex 6x8
Orientation
(NE)
(NE)
(NE)
(NE)
(NE)
(NE)
(SE)
(SE)
(SE)
Shaded Unshaded
Area
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
Area
X
.X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
0.0
36.5
11.3
55.8
0.0
36.5
5.0
55.8
0.0
36.5
11.3
55.8
0.0
36.5
9.0
55.8
0.0
36.5
40.0
55.8
0.0
36.5
40.0
55.8
0.0
36.5
30.0
50.3
0.0X
36.5+
30.0X
50.3=
0.0X
36.5+
48.0X
50.3=
Page Total
Btu/hr
12,197
7,
7,
7,
41
Btu/hr
630
279
630
502
2,230
2,230
1,508
1,508
2,413
11,931
Internal Gain Btu/hr
Occupants 10.3 Occupants X 245 Btuh/occ. 2,;
Equipment 3,437 Floor Area X 0.50 w/sgft =
Infiltration: 1.064 X 1.27 X 220.52 X 42 = C
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 90.331
Latent Gain Btu/hr
Occupants 10.3 Occupants X 155 Btuh/occ. = 1,598
Infiltration: 4,771 X 1.27 X 220.52 X 0.00523 = 6,969
Air Sensible CFM ElA AW
• TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1.598
I EnemyPro 6.5 by EneMySoR User Number: 6712 RunCode: 2015-04-23709:38:06 ID: Paae 22 of 26 1
•
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Frana Residence 4/23/2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name altered residence Outdoor Dry Bulb Temperature 112 OF
Floor Area 3,437.0 ft' Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF
ue Surfaces
Orientation
Area U -Factor CLTD'
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
ex6x4.5
ex 5x8
ex 2x3
ex 2x3
ex 2x3
ex 7.5x8
ex 2x2.5
ex 2.5x8
ex 1.5x2.5
Orientation
(SE)
(SE)
(SE)
(SE)
(SE)
(SE)
(SM
(SIM
(SIAL
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
0.0
36.5
27.0
50.3
0.0
36.5
40.0
50.3
0.0
36.5
6.0
50.3
0.0
36.5
6.0
50.3
0.0
36.5
6.0
50.3
0.0
36.5
60.0
50.3
0.0
36.5
5.0
50.3
0.0
36.5
20.0
50.3
0.0X
36.5+
3.8X
50.3=
Page Total
Btu/hr
01
Btu/hr
1,357
2,011
302
302
302
3,017
251
1,006
191
8,7381
rnal Gain
Btu/hr
ants
10.3 Occupants X
245 Btuh/occ.
= 2,!
ment
3,437 Floor Area X
0.50 w/sgft
= 5
Infiltration: 1.064 X 1.27 X 220.52 X 42 =
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 90,331
Latent Gain Btu/hr
Occupants 10.3 Occupants X 155 Btuh/occ. = 1,598
Infiltration: 4,771 X 1.27 X 220.52 X 0.00523 = 6,969
Air Sensible CFM ELA AW
ROOM 1
1 EnergyPro 6.5 by EnergVSoft User Number: 6712 Run Code: 2015-0423709:38:06 ID: Page 23 of 26
F- �
LA
C
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Frana Residence
1 4/23/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
altered residence
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,43 7. 0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
GLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
1
0
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area GLF
Btu/hr
ex 2.5x5
I's V109 0.0 X 36.5 +
12.5 X
50.3 =
628
ex 2.5x5
(SVV) 0.0 X 36.5 +
12.5 X
50.3 =
628
ex 2.5x5
(S K9 0.0 X 36.5 +
12.5 X
50.3 =
628
ex 2x2.5
(S K9 0.0 X 36.5 +
5.0 X
50.3 =
251
ex 7.5x8
(NKK 0.0 X 36.5 +
60.0 X
55.8 =
3,346
ex 4x8
(NVIO 0.0 X 36.5 +
32.0 X
55.8 =
1,784
X +
X
=
X +
X
=
X +
X
=
Page Total
7,26
Internal Gain
Btu/hr
Occupants
10.3 Occupants X 245
Btuh/occ.
=
2,526
Equipment
3,437 Floor Area X 0.50
w/sgft
=
5,865
Infiltration: 1.064
X 1.27 X 220.52 X 42 =
12,473
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
90,331
Latent Gain
Btu/hr
Occupants
10.3 Occupants X 155
Btuh/occ.
=
1,598
Infiltration: 4,771
X 1.27 X 220.52 X 0.00523 =
6,969
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,598
EnemyPro 6.5 by EneMySoft
User Number: 6712 Run Code: 2015-04-23T09:38:06 ID:
Page 24 of 26
0
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Frana Residence
1 4/23/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
new addition
Outdoor Dry Bulb Temperature
.1120F
Floor Area
240.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof Attic
(IM 240.0 X 0.0260
X
56.0 =
349
R-21 Wall (W.21.24.16)
(NE) 340.0 X 0.0690
X
29.0 =
680
R-21 Wall (W.21.2x6.16)
(SE) 204.0 X 0.0690
X
31.0 =
436
R-21 Wall (W.21.24.16)
(SW) 252.0 X 0.0690
X
31.0 =
539
R-21 Wall (W.21.2x6.16)
(NIM 80.0 X 0.0690
X
30.2 =
167
*R-13 Wall
101.0 X 0.1020
X
0.0 =
0
X
X
=
X I
X
=
X
X
=
Page Total
2,172
Items shown with an asterisk (`) denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
new 7x8.46.24
(SE) 0.0 X 18.1 +
56.0 X
23.6 =
1,323
new 8x8.46.24
(SW) 0.0 X 18.1 +
64.0 X
23.6 =
1,512
new 3x8.46.24
(SW) 0.0 X 18.1 +
24.0 .X
23.6 =
567
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +
X
=
Page Total
3,403
Internal Gain
Btu/hr
Occupants
0.7 Occupants X 245
Btuh/occ•
=
176
Equipment
240 Floor Area X 0.50
w/ggft
=
410
Infiltration: 1.064
X 1.27 X 15.40 X 42 =
871
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
7,032
Latent Gain
Btu/hr
Occupants
0 7 Occupants X 155
Btuh/oca
=
112
Infiltration: 4,771
X 1.27 X 15.40 X 0.00523 =
487
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
112
EnemvPro 6.5 by EnemySoft
User Number. 6712 Run Code: 2015-04-23T09:38:06 ID:
Page 25 of 26
•
�J
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Frana Residence
4/23/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
2nd floor res
Outdoor Dry Bulb Temperature
112 OF
Floor Area
680.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
t1TD'
Btulhr
Default 1978 to present
(W) 680.0 X 0.0790
X
56.0 =
3,008
R-13 Wall
(NE) 587.5 X 0.1020
X
29.0 =
1,738
R-13 Wall
(SE) 505.0 X 0.1020
X
31.0 =
1,597
R-13 Wall
(SlM 596.2 X 0.1020
X
31.0 =
1,885
R-13 Wall
(NW) 462.0 X 0.1020
X
30.2 =
1,425
`R-13 Wall
212.0 X 0.1020
X
0.0 =
0
X
X
=
X
X
=
X
X
=
Page Total
9,653
Items shown with an asterisk (`) denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
ex 2.5x5
(NE) 0.0 X 36.5 +
12.5 X
55.8 =
697
ex 5x5
(SE) 0.0 X 36.5 +
25.0 X
50.3 =
1,257
ex 5x8
(SE) 0.0 X 36.5 +
40.0 X
50.3 =
2,011
ex 12.5x2.5
(SIM 0.0 X 36.5 +
3.8 X
50.3 =
191
ex 5x8
(NM 0.0 X 36.5 +
40.0 X
55.8 =
2,230
ex 2x4
(NW) 0.0 X 36.5 +
8.0 X
55.8 =
446
ex 2x2.5
(NIAq 0.0 X 36.5 +
5.0 X
55.8 =
279
ex 2x2.5
(NW) 0.0 X 36.5 +
5.0 X
55.8 =
279
X +
X
=
Page Total 1
7,390
Internal Gain
Btu/hr
Occupants
2.0 Occupants X 245
Btuh/occ_
=
500
Equipment
680 Floor Area X 0.50
w/sgft
=
1,160
Infiltration: 1.064
X 1.27 X 43.63 X 42 =
2,468
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
21,171
Latent Gain
Btu/hr
Occupants
2 0 Occupants X 155
Btuh/occ.
=
316
Infiltration: 4,771
X 1.27 X 43.63 X 0.00523 =
1,379
Air Sensible
CFM Et.A AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
316
EnemvPro6.5 by EnemySoft
User Number: 6712 Run Code: 2015.04-23709:38:06 ID:
Page 26 of 26
CERTIFIO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 410D
Project Name: Frana Residence Calculation Date/Time: 09:35, Thu, Apr 23, 2015
Calculation Description: Title 24 Analysis
Input File Name: Frana-Stracts-15.xmi
CF10F-01
Pagel of 9
GENERAL INFORMATION
01
Project Name Frana Residence
Building Complies with Computer Performance
02
Calculation Description Title 24 Analysis
r . • .. r � • �
This building incorporates features that requirexv field tes�tingr f+and/orv veri,,,,.-.fication by ai certified HERS rateri untder�.the supervision of a CEC-approved HERS provider.
03
03
Project Location Lot 286 The Hideaway
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-3c (710)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.5
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 315
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (FT2) 4357
15
Number of Zones 3
16
Slab Area (FT2) 3677
17
Number of Stories 2
18
Addition Cond. Floor Area 240
19
Natural Gas Available Yes
20
Addition Slab Area (FT2) 240
21
Glazing Percentage (%) 18.7%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
r . • .. r � • �
This building incorporates features that requirexv field tes�tingr f+and/orv veri,,,,.-.fication by ai certified HERS rateri untder�.the supervision of a CEC-approved HERS provider.
03
This building incorporates one'oi more Special Features s_hown;below�
Ia t i t.. f A J
f 1 V t
L --F i.. i A
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use
M (kTDV/ft2-yr)
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Improvement
n
Space a
12.25
9.51
2.74
22.4%
R7
Spao9C0�1
287.68
268.82
18.86
6.6%
r 1 jirent o
0.00
0.00
7.55
0.00
0.00
0.0%
0.0%
a Q H–egin
7.55
Pi�%�I O et
—
0.00
0.00
—
ire 9derhy Total
307.48
285.88
21.60
7.0%
: U5 -1b.
m -77
-
zOCY �z
n Numbe,, 0)
Standards - 2013 Residential Compliance
Registration Date/Time: 2015-04-23 09:51:07
Report Version - CF1R-04012015-710
HERS Provider: CaICERTS inc.
Report Generated at: 2015-04-23 09:37:30
CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD CF10F-01
Project Name: Frana Residence Calculation Date/Time: 09:35, Thu, Apr 23, 2015 Page 2 of 9
Calculation Description: Title 24 Analysis Input File Name: Frana-Stracts-15.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High Quality Insulation Installation (QII)
Cooling System Verifications:
— None —
HVAC Distribution System Verifications:
• — None —
Domestic Hot Water System Verifications:
• —None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Tide 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system. rt y-... — _
Reference Energy Usef Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)* y 345.62 {{ i 324.02 21.60 6.2%
NZA
includes calculated Appliances and Miscellaneous EnergytU�se (AMEU)
ERS PROVIDER
BUILDING —FEATURES INFORMATION
D 01
02
03
04.
05
06
07
M 1
Zone Type
Number of Dwelling
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Number of Ventilation
Number of Water
C
Project Name= __q
Conditioned Floor Area (ft2)
Units
Number of Bedrooms
Number of Zones
Cooling Systems
Heating Systems
Fran. ate -side k 1
4357
1
9
3
1
1
= I ��J
Z INFU N� Ti
_< r Cn
02
03
04
05
06
07
C -n
ZoQi .0
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
r e
Conditioned
HVAC1
3437
14
DHW Sys 1
fTi Z
Conditioned
HVAC1
240
14
DHW Sys 1
2nd floo" K
Conditioned
HVAC1
680
14
DHW Sys 1
Registration Number: 215-A0106559A-000000000-0000 Registration Date/Time: 2015-04-23 09:51:07 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-23 09:37:30
CERTIF* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOD
Project Name: Frana Residence Calculation Date/Time: 09:35, Thu, Apr 23, 2015
Calculation Description: Title 24 Analysis
Input File Name: Frana-Stracts-15.xmi
CF1�F-01
Page 3 of 9
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door
Area (ft)
Tilt
(deg)
Status
Verified
Existing
Condition
NE Wall ex
residence
R-13 Wall
45
Left
2350
116.6
90
Existing
No
SE Wall ex
residence
R-13 Wall
135
Back
2620
253
90
Existing
No
SW Wall ex
residence
R-13 Wall
225
Right
2350
71.3
90
Existing
No
NW Wall ex
residence
R-13 Wall
315
Front
2620
112.1
90
Existing
No
Roof
residence
Defaul: 1978 to present
2757
Existing
No
NE Wall
addition
R-21 Wall (W.21.2x6.16)
45
Left
340
90
New
N/A
SE Wall
addition
R-21 Wall (W.21.2x6.16)
135
Back
260
56
90
New
N/A
SW Wall
addition
R-21 Wall (W.21.2x6.16)
225
Right
340
88
90
New
N/A
NW Wall
addition
R-21 Wall (W.21.2x6.16)
315
Front
80
90
New
N/A
Roof 2
addition
R-38 Roof Attic
240
New
N/A
NE Wall ex 2
2nd floor
R-13 Wall
45
Left
600
12.5
90
Existing
No
SE Wall ex 2
2nd floor
r�' _ J�y13 Waller` d
- � 4135
w ((Back
! [ y�.57,0 C:Z�
65
90
Existing
No
SW Wall ex 2
2nd floor.,
tR-13 Wally €
1*�225�i I
Right_
11 fJ 600 {(
3.8
90
Existing
No
NW Wall ex 2
2nd floor)
'R=13 Wall "`" 315-
_ —Front/
-'V
� 520 �'` " 58
90
Existing
No
Roof 3
2nd floor
Defaul:11978`tO present
I— r1 1IL-.,'
680 rN I
Existing
No
ATTIC
01
02
03
04
05
06
07
08
09
10
Radiant
Statu
Verified Existing
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Barrier
Cool Roof
s
Condition
DAttic residence
Attic Roofresidence
Ventilated
3
0.1
0.85
No
No
En9ti
No
MY 0
A additi&
Attic Roofaddition
Ventilated
3
0.1
0.85
No
No
New
No
4 r d flzr
Attic Roof2nd floor
Ventilated
3
0.1
0.85
No
No
Ex9 ti
No
Z U . —1
Q
< �O�
C -n
M JO
oho
egistration Numb—��:
A Building Energy Ef
106559A-000000000-0000 Registration Date/Time: 2015-04-23 09:51:07
Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710
HERS Provider: CaICERTS inc.
Report Generated at: 2015-04-23 09:37:30
CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE F*OD
Project Name: Frana Residence Calculation Date/Time: 09:35, Thu, Apr 23, 2015
Calculation Description: Title 24 Analysis
Input File Name: Frana-Stracts-15.xml
CFOF-01
Page 4 of 9
WINDOWS
01
02
03
04 05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Multiplie
Height (ft) r
Area (ft)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
ex 2.5x4.5
NE Wall ex (Left -45)
-
- 1
11.3
0.71
0.60
Insect Screen (default)
Existing
No
ex 2x2.5
NE Wall ex (Left -45)
-
-- 1
5.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 2.5x4.5 2
NE Wall ex (Left -45)
-
- 1
11.3
0.71
0.60
Insect Screen (default)
Existing
No
ex 2x4.5
NE Wall ex (Left -45)
-
- 1
9.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 5x8
NE Wall ex (Left -45)
-
- 1
40.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 5x8 2
NE Wall ex (Left -45)
-
- 1
40.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 5x6
SE Wall ex (Back -135)
-
- 1
30.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 5x6 2
SE Wall ex (Back -135)
-
- 1
30.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 6x8
SE Wall ex (Back -135)
-
- 1
48.0
0.71
0.60
Insect Screen (default)
Existing
No
ex6x4.5
SE Wall ex (Back -135)
-
- 1
27.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 5x8 3
SE Wall ex (Back -135)
-
- 1
40.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 2x3
SE Wall ex (Back -135) f�
i 1 l�
,- ((! 1-#i
(it 6.0
i 0. 7,1
0.6_Ot
Insect Screen (default)
Existing
No
ex 2x3 2
SE Wall ex (Back-135)V,,f
I f �i 1 11
'6`.0
10.7 1
10; 60
Insect Screen (default)
Existing
No
ex 2x3 3
SE Wall ez'(Back-135) `"
`'' �_
- _ 1 "_
`_"6.011
'0.71 _
6'60' '
Insect Screen (default)
Existing
No
ex 7.5x8
SE Wall ex (Ba6k-`.135) 1-1
C rN
-t- Ei 1
60.0 1
L0:71 t
0:60
Insect Screen (default)
Existing
No
ex 2x2.5 2
SW Wall ex (Right -225)
-
- 1
5.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 2.5x8
SW Wall ex (Right -225)
-
- 1
20.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 1.5x2.5
SW Wall ex (Right -225)
-
- 1
3.8
0.71
0.60
Insect Screen (default)
Existing
No
ex 2.5x5
SW Wall ex (Right -225)
-
- 1
12.5
0.71
0.60
Insect Screen (default)
Existing
No
D ex 2.5x5 2
SW Wall ex (Right -225)
-
- 1
12.5
0.71
0.60
Insect Screen (default)
Existing
No
m ex 2.5x5
SW Wall ex (Right -225)
-
- 1
12.5
0.71
0.60
Insect Screen (default)
Existing
No
2 F
7.. 8
SW Wall ex (Right -225)
NW Wall ex (Front -315)
-
--
- 1
- 1
5.0
60.0
0.71
0.71
0.60
0.60
Insect Screen (default)
Insect Screen (default)
Existing
Existing
No
No
Qex 80
NW Wall ex (Front -315)
-
- 1
32.0
0.71
0.60
Insect Screen (default)
Existing
No
n63
SE Wall (Back -135)
-
- 1
56.0
0.46
0.24
Insect Screen (default)
New
N/A
<
'9 x8 .42
SW Wall (Right -225)
-
- 1
64.0
0.46
0.24
Insect Screen (default)
New
N/A
2
SW Wall (Right -225)
-
- 1
24.0
0.46
0.24
Insect Screen (default)
New
N/A
NE Wall ex 2 (Left -45)
-
- 1
12.5
0.71
0.60
Insect Screen (default)
Existing
No
x xrFi7
77 rri
SE Wall ex 2 (Back -135)
-
- 1
25.0
0.71
0.60
Insect Screen (default)
Existing
No
R gistration Numbgri --'A 106559A-000000000-0000 Registration Date/Time: 2015-04-23 09:51:07 HERS Provider: CaICERTS inc.
Efficien Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-23 09:37:30
CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOOD
Project Name: Frana Residence Calculation Date/Time: 09:35, Thu, Apr 23, 2015
Calculation Description: Title 24 Analysis
Input File Name: Frana-Stracts-15.xml
CF1�F-01
Page 5 of 9
ex 5x8 4
SE Wall ex 2 (Back -135) —
— 1
40.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 12.5x2.5
SW Wall ex 2 (Right -225) —
— 1
3.8
0.71
0.60
Insect Screen (default)
Existing
No
ex 5x8 5
NW Wall ex 2 (Front -315) —
— 1
40.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 2x4
NW Wall ex 2 (Front -315) —
— 1
8.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 2x2.5 4
NW Wall ex 2 (Front -315) —
— 1
5.0
0.71
0.60
Insect Screen (default)
Existing
No
ex 2x2.5 5
NW Wall ex 2 (Front -315) —
— 1
1 5.0
0.71
1 0.60
1 Insect Screen (default)
Existing
No
DOORS
01 02 03 04 05 06
Name Side of Building Area (W) U -factor Status Verified Existing Condition
Door NW Wall ex 20.1 0.50 Existing No
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
/�
j
i i ( — �� , I C -)) � - I I � . (:
2x4>Top Chord of Roof Truss @ 24-
"P C
_— f �
0.644
• Cavity / Frame: no insul. / 2x4 Top Chrd
Roof Deck. Wood Siding/sheathing/decking
Attic Roofresidence
Attic Roofs
`Wood Framed Ceifn")
in. O.C. ri
(none
Roofing: Light Roof (Asphalt Shingle)
�#
E
�}
R S R 0
x �,
I D�:
R
Inside Finish: Gypsum Board
Ceilings (below
i 1
i"
�f
Cavity/Frame: R -9.1/2x4
Defaul: 1978 to present
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R11
0.083
Over Floor Joists: R-1.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R -13/2x4
• Exterior Finish: Wood
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
• Cavity/ Frame: no insul. / 2x4 Top Chrd
DAttic
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Roofadditi(M n
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
r
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 oofti
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
0!7
Inside Finish: Gypsum Board
z iso
Cavity / Frame: R-21 / 2x6
IJ) (1)
• Exterior Finish: Wood
[-
R�1 Wa 21 2$6.1
Exterior Walls
Wood Framed Wall
2x6 16 in. O.C.
@
R 21
0.066
Siding/sheathing/decking
C M.0
1V
• Cavity/ Frame: no insul. / 2x4 Top Chrd
�
JLAtfttic'LM
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
ffd C:
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
zum J6559A-000000000-0000
R istration Number.Registration Date�me: 2015-04-23 09:51:07 HERS Provider: CaICERTS inc.
uildin EnergyEfficieandards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-23 09:37:30
CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD
Project Name: Frana Residence Calculation Date/Time: 09:35, Thu, Apr 23, 2015
Calculation Description: Title 24 Analysis Input File Name: Frana-Stracts-15.xml
CF*F-01
Page 6 of 9
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Covered Slab
residence
3437
316
None
0.8
No
Existing
No
Covered Slab 2
addition
240
j 47
j None
0.8
No
New
j No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Required Not Required Not Required —
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
li�Number
(Distribution Typ
��� lWater.Heater
of
Heaters
Solar
Fraction
(°/a)
Status
Verified Existing
Condition
DHW Sys 1
DHWPipe;I
isuleGon All Lin`es�o LL -.-t,
3 t, jDHW.He6ter1 U2a
0.61 EF
Annual
Existing
No
� % I % r r -v. r^ r -r rt rte.: % r r
WATER HEATERS ti 4 40 — 4 . " .
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.61 EF
40000-Btu/hr
0
0
WATE DATING - ATION
T 01
l-I
o !—
02
Pipe Insulation
03
04
05
06
07
Parallel Piping
Compact Distribution
Point -of Use
R6dlreulatiort wlttt
Manual Control
Recirculailun with
Sensor Control
DFLq z
n/a
n/a
n/a
n/a
n/a
n/a
v v vi
CyXQ
C -n
M
On C
,Istration;aui rm2 0, i
Building Energy FACi�r t
0000000-0000 Registration Date/Time: 2015-04-23 09:51:07
- 2013 Residential Compliance Report Version - CF1R-04012015-710
HERS Provider: CaICERTS inc.
Report Generated at: 2015-04-23 09:37:30
CERTIF* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE &WD
Project Name: Frana Residence Calculation Date/Time: 09:35, Thu, Apr 23, 2015
Calculation Description: Title 24 Analysis Input File Name: Frana-Stracts-15.xml
CF1�F-01
Page 7 of 9
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
Zonally Controlled
Multi -speed
Compressor
Heating System
Cooling System
S IitAirCond - Split air cjonditioriin
p ys 1 ��g
s stem i
Bypass Duct
rlp',
t1 ilii
11� 1
Verified Existing
Condition
1112
]
f
i N �r
No
N/A
Distribution
Fan
Floor Area
No
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
HVAC1
Other Heating and
Heating
Yes
Cooling
Yes
Air Distribution
HVAC Fan
4357
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
Name
System Type J«1~
Efficiency
7 i1 EERY ram (7_ --,,, ;SEER,
Zonally Controlled
Multi -speed
Compressor
HERS Verification
Cooling Component 1
S IitAirCond - Split air cjonditioriin
p ys 1 ��g
s stem i
Bypass Duct
rlp',
t1 ilii
11� 1
Verified Existing
Condition
1112
]
f
i N �r
No
N/A
HVAC - DISTRIBUTION SYSTEMS `A t' -"t I-- t"( �> t-1 ti U V ! U t K
01 02
03
04
05
06
07
08
09
10
Name Type
Duct Leakage
Insulation
R -value
Supply Duct
Location
Return Duct
Location
Bypass Duct
Status
Verified Existing
Condition
HERS
Verification
Q istrib�ttio located in attic
ysystem 1
Existing (not
specified)
4.2
Attic
Attic
None
Existing
No
N/A
m - t J 1
I (Indoo iP'4uz113y)F
02 03 04 05
IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
I 4W IftVent 0 Default 0 Not Required
r% V J L
OLIN Lig I
02 03 04
0— Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans
a 1 61 0.52459 1
I L �NuZ0106559A-000000000-0000 Registration Date/Time: 2015-04-2309:51:07
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710
HERS Provider: CaICERTS inc.
Report Generated at: 2015-04-23 09:37:30
f ` y
U
C_
N
d'
W
U
U
L
w
O
L
CL
N
K
w
2
Gl
0
C
O
00
G1
cc
O
M
n
M
01
O
M
N
V
O
Ln
r-1
O
N
Y
CLI
Y
I
cu
C
cu
(9y
O
O.
w
W-
CITY OF LA QUINT
BUILDING & SAFETY DEPT,N
APPROVED � �
FOR CONSTRUCTION
Z =
w
to
O C
DATE BY
N
Q
U
CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE JOD
Project Name: Frana Residence ation DatefTime: 09:35, Thu, Apr 23, 2015
Calculation Description: Title 24 Analysis
Input File Name: Frana-Stracts-15.xml
CF1*F-01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2015-04-23 09:51:07
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted!jo-the enforcement agencyJor approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature1
%uXi.�cai
Tim Scott
L.�-� r,
Company:
Date, Signed,
09:51:07
Scott Design and Title 24, Inc.
2M15-042
Address:
License:
77085 Michigan Drive
na
City/State/Zip:
Phone:
Palms -B
(760) 200-4780
M
WO
71
c-
00Do
��z
o�g
ca C)
Digit 11 5gned a RAS. s t
c m
info tion. �
z°O'1M.Z�
Reg ation Number: 24-01 6
CA er Efficiency Sta
signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the
Registration Date/Time: 2015-04-23 09:51:07
ards - 2013 Residential Compliance Report Version - CF1R-04012015-710
HERS Provider: CaICERTS inc.
Report Generated at: 2015-04-23 09:37:30