Loading...
08-0926 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Tit!t 4 4 Qu&& BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 08-00000926 Property Address: 53785 VIA PISA APN: 772-530-052- - - Application description: DWELLING.- SINGLE FAMILY DETACHED Property Zoning: LOW DENSITY RESIDENTIAL Audication valuation: 443992 Applicant: / Architect�or%Engli�ne�er�: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 818923 Date: 2L ntractor. 1:1) 6M ua Q4.1- - OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5. Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT Owner: D RICHARD SHERER 77 FRONT STREET DANVILLE, CA 94PE VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Jr" FEB 1 2C@ � CITY t?F 4 z.iL!sy iA Flys; .• �,�,, � �:tp J: Contractor: FEDDERLY & ASSOCIATES 38747 NOPALES ROAD PALM DESERT, CA 92211 (760).773-5205 Lic. No.: 818923 2/11/10 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is Xissued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EVER INS Policy Number 760000440081 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section / 3700 of the abo(rrCC1od\ee, I shall forthwith comply with those provisions. 115=e:-141" ? PPlicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives off this county to enter upon a above-mentioned property for inspection purposes. _ ___.�-_7 I �� nature (Applicant or Agent) 1 A Application Number . . . . .. 08-00000926 Structure Information 5,092SF DWELLING/VB/RES-3/CLASS A -FR Other struct info . . . . . CODE EDITION 2007CODES # BEDROOMS 3.00 FIRE SPRINKLERS NO GARAGE SQ FTG 990.00 PATIO SQ FTG 989.00 NUMBER OF UNITS 1.00 --------------------------------------=------------------------------------- 2ND FLOOR SQUARE FOOTAGE 450.00 Permit . . . BUILDING PERMIT Additional desc . Permit'Fee . . . . '1843.50 Plan Check Fee 1198.28 Issue•Date . . . . Valuation . . . . 443992 Expiration Date . . . 3/24/10 Qty Unit Charge Per Extension BASE FEE 639.50 344.00 3.5000 ------------------------------------------------'---------------------------- THOU BLDG 100,001-500,000 1204.00 Permit ELEC-NEW RESIDENTIAL Additional desc'. . Permit Fee . . . . 228.02 Plan Check Fee 59.21 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/24/10 Qty Unit Charge Per Extension BASE FEE 15.00 5092.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 178.22 990.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 19.80 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/24/10 Qty Unit Charge Per Extension ----------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 183.50 Plan Check Fee 62.13 LQPERMI Application Number . . . . . 08-00000926 Permit . . . . MECHANICAL Issue Date Valuation . . . . 0 Expiration Date 3/24/10 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 3.00 11.0000 EA MECH FURNACE >100K 33.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 3.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 49.50 5.00 6.5000 EA MECH VENT PAN 12.50 2.00 6.5000 EA MECH EXHAUST HOOD ---------------------------------------------------------------------------- 13.00 Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 202.50 Plan Check Fee 61.31 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/24/10 Qty Unit Charge Per Extension BASE FEE 15.00 20.00 6.0000 EA PLB FIXTURE 120.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 14.00 .7500 EA PLB GAS PIPE >=5 10.50 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments REVISION 1 (PRIOR TO PERMIT ISSUANCE): 5,092SF DWELLING/VB/RES-3/CLASS A -FR - 2 STORY RESIDENCE ONLY. THIS PERMIT DOES NOT INCLUDE POOL, SPA, WATER FEATURES OR BLOCK WALLS. 2007 CALIFORNIA BUILDING CODES. ***NOTE: PERMIT FEES ADJUSTED TO REVISED (SMALLER) DWELLING WITH ANY CREDITS BEING APPLIED TO PERMIT FEES DUE. ADDITIONAL PLAN CHECK FEES FOR'THE REVISED DWELLING DESIGN HAVE BEEN ASSESSED HOURLY SINCE PREVIOUS PLAN COMPLETED REVIEW AND WAS READY TO ISSUE*** September 25, 2009 8:57:57 AM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 609.98 LQPERMIT Application Number 08-00000926 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 125.97 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE 30.00 HOURLY PLAN CHECK 1385.00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 44.40 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Permit Fee Total 2472.52 Plan Check Total 1380.93 Other Fee Total 6670.35 Grand Total 10523.80 LQPERMI� Paid Credited Due 61.42 .00 2411.10 1380.93 .00 .00 155.97 .00 6514.38 1598.32 .00 8925.48 r - Bin # ONTO City of La Quints Building &r Safety Division Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit #P.O. oqo Project Address: 53785 Via Pisa Owner's Name: Richard Scherer A. P. Number: 772-530-052 Address: 77 Front Street Legal Description: City, ST, Zip: Danville, CA 94526 Contractor:::A:»»:::::;>:?:z«z<•>::»:<:::>::;::::: ytvl 1� Telephone: (9 2 5) 838-3838 Project Description: SFD Address: City, ST, Zip: Telephone: ;<. • .>; �:�<ss.<.>:z:»>�.':;>>:� `�>�"_'> State Lic. #.: City Lic. #: c ., g�; esig Bo E�on "/;i91 A 6 h)et e ss 4 8�a t /V �f 1 ey Ro � tty�ST, Z: Sancta/BaTbd� 31 Tee ho e: (8/5/ 9:;.. •. .::<: :, : ' < ;µ :>':<> ate 'cl : e 2 3 9 ; .� � "::'."•;:<:;;.:.:.:;;>:<�.:.:<:;:<;<:;>.::;f> '` • " "`'>?» "' ` "' e C ct ers . e 1' s G� �e►srAr�T : T,,i �75t4�-t 160 ,, ems, Construction Type: V - N R -1 YP Occupancy. Project type (circle one): New Add'n Alter Repair Demo S .*Ft : 4, 9 8 9 q #Stories: 2 #Units: NA ne fntac a 0")6 Estimated Value of Project: $1,600.,000 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Pian Check submitted Item Amount Structural Calcs. Truss Cafes. Reviewed, ready for corrections Called Contact Person Plan Check Deposit Plan Check Balance - oO. Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan god Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date or permit issue Fri 4 School Fees 1 Permit Fees �� W tOC�b�iiC7i� FtNAN�6pF— rA� r - NEW CENTURY TITLE COMPANY RECORDING REQUESTED By: New Century Title Company - Riverside Title ORDERNO- 2372227 ESCROW NO.: 33060879-SVO AND WHEN RECORDED MAIL To. Richard Scherer Melanie Scherer 77 Front Street Danvik CA 94526 DOC * 2006-0943444 12/27/2006 08:00A Fee:13.00 Page t of 3 Doe T Tax Paid Recorded in Official Records County of Riverside Larry W. Ward Assessor, County Clerk d Recorder 1111111111111111111111111111111111111111111111111111111 I sI 1 R I U I PAGE I SIZE I DA I MISC i LONGI RFD t;urY + S R I U PAGE SIZE DA I MISC I LONG RFD COPY 1rL� 62-o A.P.N. 777-190.012 . . GRANT DEED SMF MrGaMVA THE UNDERSIGNED GRANTORS) DECLARE(S) that documentary 1bran3fer tax Is $1,320.00 (County) $.00 ( X) computed on full value of property conveyed, or ( ) computed on full value less liens or encumbrances remaining at time of sale 6037 ( X) City of La Quint FOR A VALUABLE CONSIDERATION, rftWPt of which b hereby admowkdged, H. Ilhan Rdioglu and Dawn M. Refloglu, Trustees of the Refloglu Revocable Trust dated June 16, 1992, hereby GRANT(S) to Richard Sd►e w, a married man as his sole and separate property the following described real property In the City of La Quint, County of Riverside, State of Callfomla: Please see attached EXHIBIT *A* and commonly Wx wn as: 53785 Via Pisa -trot 287, La Quinta, CA 92253 Dated: December 7, 2006 .5-. 0-.Vn H. Ilhan Reflogty„Trust "STATE OF /�!) 1 COUNTY f %GO - / ON %YO8MRE me V 0 2!9A, Davin M. Refloglu, Tnlstee %.J. �•.vc ••vc• Y W YR WIR.QJ person* appeared _ 1 H e �t-�9lc c Qr M. S 5& Personally known to me (or prored'tu me on the Dads of §w0a&Y evidence) to be the Person(s) whose e( are s Aw(bed to are wfWn Instrument and adoxw4edged to me that 4+dslydthey executed the same In W%AwXeh authorised capadty(ks), and that by hK40fttheir sgrrature(s) on the Instrument '~�v or the endty upon behalf of wMdh the persons) ado executed the i soumert. WITNESS my hand and otW 1. Signature j= J. SM CsAMEL Cptltrtton 81428433 f nrNotary Pum - C490M0 Son MCQeo County My Comm. EhrptrMM 28.2007 - mr sant rloaq sort] warn uew - Lnumqual (M) IZ-05 MAIL TAX STATEMENTS AS DIRECTED ABOve EXHIBIT "A" PARCEL NO. 1: LOT 287 OF AMENDED TRACT NO. 298W2 AS SHOWN ON A SUBDIVISION MAP RECORDED ON DECEMBER 12, 2002 IN BOOK 327, PAGES S6 TO 88, INCLUSIVE, OF MAPS, IN THE OFFICE OF THE RIVERSIDE COUNTY RECORDER. EXCEPTING THEREFROM TO GRANTOR, AND ITS SUCCESSORS, ASSIGNS, INVITEES, LICENSEES AND EMPLOYEES, TOGETHER WITTHE RIGHT TO GRANT AND TRANSFER ALL OR A PORTION OF THE SAME, ALL EASEMENTS AND RIGHTS FOR ACCESS, INGRESS, EGRESS, ENCROACHMENT, MAINTENANCE, DRAINAGE, SUPPORT, AND FOR OTHER PURPOSES OVER THE ASSOCIATION MAINTENANCE AREAS AND OTHER PORTION OF THE LOT. PARCEL 2: NOWEXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, EGRESS, DRAINAGE, MAINTENANCE, REPAIRS AND FOR OTHER PURPOSES, ALL AS DESCRIBED IN THE DECLARATION. V I TITLE 24 REPORT I pC�2�pm� � SEP 21 2009 IUI Title 24 Report for: Scherer Residence 53-785 Via Pisa La Quinta, CA 92253 Project Designer: Integral Design 40-471 Padova Drive Indio, CA 92203 (760) 409-1206 Report Prepared By: C.J. McFadden CM Energy Consulting P.O. Box 4655 Palm Desert, CA 92211 (760) 449-1308 CITY OF LA QUINTA Job Number: BUILDING 8 SAFETY DEPT. APPROVED FOR CONSTRUCTION Date: I DATE1101 BY, 9/18/2009 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft _ Job Number: User Number: 7403 I TABLE OF CONTENTS . I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary Room Load Summary 1 2 3 9 11 12 16 EnergyPro 4.4 by EnergySoft Job Number. User Number: 7403 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R SrhPrPr Residence (NE) 45 deg Fuel Type: Natural Gas 9/18/2009 Date Project Title 93-785 Via Pica I a Quinta Ratio: 19.5% Avg. SHGC: 0.31 Project Address Zone Name Floor Area Volume Building. Permit # QM Enerav Consultino (760) 449-1308 Documentation Author Telephone Plan Check/Date EnerqyPro Compliance Method CA Climate Zone 15 Climate Zone Field Chack/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.40 4.69 -2.29 Space Cooling 62.31 50.81 11.50 Fans 8.85 ' 8.53 0.33 Domestic Hot Water 4.75 6.34 -1.60 Pumps 0.00 0.00 0.00 Totals 78.31 70.37 7.94 Percent better than Standard: BUILDING COMPLIES - HER Building Type: [j] Single Family ❑ Addition ❑ Multi Family ❑ Existing + Add/Alt Building Front Orientation: (NE) 45 deg Fuel Type: Natural Gas Fenestration: Area: 992 ft 2 Avg. U: 0.37 Ratio: 19.5% Avg. SHGC: 0.31 BUILDING ZONE INFORMATION Zone Name Floor Area Volume 10.1% VERIFICATION REQUIRED Total Conditioned Floor Area: 5,092 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 4,642 ft2 Average Ceiling Height: 11.5 ft Number of Dwelling Units: 1.00 Number of Stories: 2 # of Units Master Redrnnm 1 379 13 790 n 9� Guest Bedroom 462 415 0_09 Living 2.801 36.413 0.55 Office 450 4.050 0.09 OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Roof Wond 1 479 0 032 R-30 R-0 0 0 Wall Wood 157 0.074 R_19 R0.0 225 90 Wall Wood 115 0.074 R_19 _R-00 970 90 Wall Wnnd 15 0 074 R-19 R-0 0 0 go Wall Wood 400 0.074 R-19 R-0.0 90 9 Wall Wood 112 0.074 R_19 R-0�0 315 9 Rnnf Wond 462 00.32 X30 -0 0 0 Wall Wood 158 0 074 R-19 -0_0 270 go Wall Wood 121 0.074 R_19 R-0.0 _0 90 Wall Wood 232 0.074 R19 _R-0.0 -9.090 Wall Wood 98 0 074 R_19 R-0 0 180 90 Roof Wood 2 351 0 032 R_30 R-0.0 0 Wall Wond 488 0.074 R-19 R-0.0 _225 90 Wall Wood 847 0.074 R_19 R-9�Q 3 15 90 nnor None 24 0.600 None R-0.0 _315 90 Wall Wood 630 0074 R19_ -R-0 O_ 45 9 Dnor Nnna 94 n 60o Nnne R-0.0 45 9Q Wall Wood 369 0074 R-19 R-0 0 135 9 Roof Wnnd 450 0 032 13.30 R-0.0 0 Wall Wood 221 0.074 R_19 R-0-0 295 9 Will Wood 178 0.074 R_1$R-0.0 315 9 Wall Wood 252 0.074 R-19 R 0 45_9Q Wall Wood 178 0.074 R_19 X0.0 X35 q Zone Type SIPP.�g Sleenina Living Living Gains Condition Y / N Status JA IV Reference Thermostat Vent Type Hgt. Area SleepingStat _$ n/a _Slefpin9Stat $ nla Liu ngStat 8 n/a Liv ngStat 8 n/a Location / Comments New 01-A7 Zone #1 New 09-A5 Zone #1 New 09-A5 Zone #1 New 09 -AS 7nne #1 New 09 -AS Zone #1 New 09-A5 Zone #1 New 01-A7 7nne #2 New 09-A5 7nne #2 New 09-A5 Zona #2 New 09-A5 Zone #2 New 09 -AS 7nne #9 New 01-A7 Zone #3 New 09 -AS Zone #3 New 09 -AS Zona #3 Now 9R -A5 7nna 84 New 09-A5 Zon New 09-A5 ZQn: Run Initiation Time: 09/18/09 15:50:51 Run Code: 1253307051 1 EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:3 of 19 1 Certificate Of Compliance: Residential Exterior Shade Type Warl 2 of 4) CF-1 R Scherer Residence Bug Screen 0.76 _ 2 Bug Screen 0.76 3 9/18/2009 Project Title 4 Bug Screen 0.76 5 Bug Screen 0.76 Date Bug Screen FENESTRATION SURFACES 7 Bug Screen 0.76 _ 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 True Cond. 0.76 Location/ # Type 13 Bug Screen Area U-Factor' SHGC2 Azm. Tilt Stat. Glazing Type 15 Comments 1 Window Rear (,SW) 160 038 NFRC.-Q.30 NFRC 925_ -90_ New Sierra Pacific Cmnt (J) 17 Zone #1 2 Window Rear (W) 48.0 0.390 NFRC 0_28 NFRC 270 90 New Sierra Pacific Frnch Dr (8) Zone #1 3 Window Front (E) 48.0 0.390 NFRC 0_28 NFRC 90 90 New Sierra Pacific Frnch Dr (5) Zone #1 4 Window Front (E) 7.3 0.380 NFRC 0_30 NFRC 90 90 New Sierra Pacific Cmnt (J) Zone #1 5 Window Front (E) 7.3 0.380 NFRC 0_30 NFRC 90 90 New Sierra Pacific Cmnt (K) Zone #1 6 Window Right (NW) 48.0 0.390 NFRC 0_28 NFRC 315 90 New Sierra Pacific Frnch Dr (6) Zone #1 7 Window Right (NW) 48.0 0.390 NFRC 0_28 NFRC 315 90 New Sierra Pacific Frnch Dr (7) Zone #1 8 Window Rear (W) 22.7 0.350 NFRC 0.38 NFRC 270 90 New Sierra Pacific Fxd (E) Zone #2 9 Window Rear (W) 24.0 0.390 NFRC 0_28 NFRC 270 90 New Sierra Pacific Frnch Dr (2) Zone #2 1Q Window Rear (W) 22.7 0.350 NFRC 0.38 NFRC 270 90 New Sierra Pacific Fxd (D) Zone #2 11 Window Right (N) 24.0 0.350 NFRC 0_38 NFRC 0 90 New Sierra Pacific Fxd (F) Zone #2 12 Window Front (E) 5.3 0.380 NFRC 0_30 NFRC 90 90 New Sierra Pacific Cmnt (G) Zone #2 -U Window Front (E) 5.3 0.38 1FIRC_030 NFRC 90 90 New Sierra Pacific Cmnt (H) Zone #2 14 Window Rear (SWI 35.0 0.390 NFRC 0_28 NFRC 225 90 New Sierra Pacific Frnch Dr (13) Zone #3 15 Window Rear (SW) 35.0 0.390 NFRC 0_28 NFRC 225 90 New Sierra Pacific Frnch Dr (14) Zone #3 16 Window Rear (SW) 35.0 0.390 NFRC 0_28 NFRC 225 90 New Sierra Pacific Frnch Dr (15) Zone #3 17 Window Rear (SW) 160.0 0.360 NFRC 0_32 NFRC: 225 90 New Sierra Pacific Sldnq Dr (9) Zone #3 18 Window Rear (SW) 93.3 0.360 NFRC 0_32 NFRC 225 90 New Sierra Pacific Sldnq Dr (10) Zone #3 19 Window Right (NW) 12.0 0.350 NFRC 0.38 NFRC 315 90 New Sierra Pacific Fxd U Zone #3 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 _ 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 _ 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Lavation/ TVDe (sf) (in.) CaD. Cond. R -Val. JA IV Reference Status Ccmments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Ccmments Slab Perimeter 105 None No Insulation 26-A1 New Zore #1 Slab Perimeter 71 None No Insulation 26-A1 New Zore #2 Slab Perimeter 234 None No Insulation 26-A1 New Zore #3 Run Initiation Time: 09/18/09 15:50:51 Run Code: 1253307051 EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:4 of 19 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Scherer Residence 9/18/2009 Project Title Date FENESTRATION SURFACES # Type Area U -Factor' SHGCZ True Azm. Tilt Cond. Stat. Glazing Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt.' Dist. Len. Hgt. Dist. Len. Hgt. Location/ Comments 2I Window Right (NW) 14.0 0.380 NFRC 0.30 NFRC -315_ .90_ New Sierra Pacific Cmnt (0) Bug Screen Zone #3 21 Window Right (NW) 12.0 0.350 NFRC 0.38 NFRC 315 90 New Sierra Pacific Fxd (R) 0.76 Zone #3 22 Window Front (NE) 12.0 0.350 NFRC 0.38 NFRC 45 90 New Sierra Pacific Fxd (B) 29 Zone #3 23 Window Front (NE) 14.0 0.350 NFRC 0.38 NFRC 45 90 New Sierra Pacific Fxd (A) Bug Screen Zone #3 24 Window Front (NE) 25.4 0.390 NFRC 0_28 NFRC 45 90 New Sierra Pacific Frnch Dr (1) 0.76 Zone #3 25 Window Front (NE) 14.0 0.350 NFRC 0_38 NFRC 45 90 New Sierra Pacific Fxd (C) Zone #3 26 Window Front (NE) 12.0 0.38 NFRC 0_30 NFRC 45 90 New Sierra Pacific Cmnt (S) Zone #3 27 Window Left (SE) 35.0 0.390 NFRC 0.28 NFRC 135 90 New Sierra Pacific Frnch Dr (11) Zone #3 28 Window Left (SE) 35.0 0.390 NFRC 0_28 NFRC 135 90 New Sierra Pacific Frnch Dr (12) Zone #3 22 Window Left (SE) 46.6 0.350 NFRC 0_38 NFRC 135 90 New Sierra Pacific Fxd (M) Zone #3 _Q Window Left (SE) 13.0 0.350 NFRC 0_38 NFRC 135 90 New Sierra Pacific Fxd (N) Zone #3 31 Window Rear (SW) 7.5 0.380 NFRC 0.30 NFRC 225 90 New Sierra Pacific Cmnt (Y) Zone #4 ,U Window Rear (SW) 7.5 0.38 NFRC -QM NERC 225 90 New Sierra Pacific Cmnt (X) Zone #4 33 Window Rear (SW) 24.0 0.390 NFRC 0_28 NFRC 225 90 New Sierra Pacific Frnch Dr (38) Zone #4 34 Window Right (NW) 7.5 0.380 NFRC 0_30 NFRC 315 90 New Sierra Pacific Cmnt (W) Zone #4 35 Window Front (NE) 7.5 0.380 NFRC 0_30 NFRC 45 90 New Sierra Pacific Cmnt (AA) Zone #4 36 Window Left (SE) 7.5 0.380 NFRC 0_30 NFRC 135 90 New Sierra Pacific Cmnt (Z) Zone #4 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt.' Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 _ 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 _ 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 _ 29 Bug Screen 0.76 _ 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen _ 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Tvoe (sf) (in.) CaD. Cond. R -Val. Condition Location/ JA IV Reference Status Ccmments PERIMETER LOSSES Insulation Condition Location/ Twe Lenqth R -Val. Location JA IV Reference Status Comments EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:5 of 19 1 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Scherer Residence 9/18/2009 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Master Bedroom Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback Guest Bedroom Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback Living Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Master Bedroom Ducted Ducted Attic 4.2 New No Guest Bedroom Ducted Ducted Attic 4.2 New No Living Ducted Ducted Attic 4.2 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 New 0.58 n/a n/a Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40.000 50 New 0.58 n a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner er Busine s & Pr fessions Code) Documentation Author Name: sw�)e CSS Name: C.J. McFadden Title/Firm: Integral Design Title/Firm: CM Energy Consulting Address: 401-A71 PaAava Drive Address: P.O. Box 4655 I A io C PIX2203 Palm Desert, CA 92211 Tele one- 60 1206 Lic. #: Telephone: 760 449-1308 19, 607 (signature) (date) (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (date) I EnerovPro 4.4 by EneravSoft User Number: 7403 Job Number: Paae:6 of 19 1 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Scherer Residence 9/18/2009 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Office Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Duct Duct ConJition Ducts Location Heating Cooling Location R -Value Statas Tested? Office Ducted Ducted Attic 4.2 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status on RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, inzulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or O`cw,►ne-r`�aor Business & Professions Code) Name: Title/Firm: Inte I Desi n Address: 40 1 Paclopta Drive Irdio, CA 9603 Teleppone: 60 -1 06 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (date) Documentation Author Name: C.J. McFadden Title/Firm: CM Energy Consulting Address: P.O. Box 4655 Palm Desert, CA 92211 Telephone: (760) 449-1308 (signature) W (date) EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Paoe:7 of 19 1 Certificate Of Compliance: Residential (Part 4 & 4) CFA R Scherer Residence 9/18/2009 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The focal enforcement aaencv determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. Plan Field The Roof "R-30 Roof' includes a Radiant Barrier. The HVAC System "Master Bedroom" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Guest Bedroom" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Living" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "Office" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field The HVAC System "Master Bedroom" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Lennox XC14 / G60UHV (5 Ton) " includes credit for a 11.5 EER Condenser. The HVAC System "Guest Bedroom" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Lennox XC14 / G60UHV (2 Ton) " includes credit for a 11.5 EER Condenser. The HVAC System "Living" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Lennox XC14 / G60UHV (5 Ton) " includes credit for a 11.5 EER Condenser. The HVAC System "Office" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Lennox XC14 / G60UHV (2 Ton) " includes credit for a 11.5 EER Condenser. EnergvPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:8 of 19 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach us?d. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist ie incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ Q ❑ apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed Floors or equivalent U -factor. ❑ ❑x ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ 0 ❑ b. outside air intake with damper and control, flue damper and control ❑ 0 ❑ 2. No continuous burning gas pilot lights allowed. ❑ N ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑ ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain 11 ❑ El (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ Q ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑ ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ Q ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ Q ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:9 of 19 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ R ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ O ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑X ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ a ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑X ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: El ® El a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. ❑ 2 ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑X ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑X ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24IE26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ © ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms,ggarages, laundry rooms, and utility rooms OR ❑ Q ❑ shall be high efficacy luminaires (except closets less than 70 ft) OR are confrolled by a dimmer switch are controlled by an occupant sensor that complies with Section 119(d) that dies not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensors) certified to comply with Section 119(d). IEnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page: 10 of 19 Residential Kitchen Lighting Worksheet WS -5R Scherer Residence 9/18/2009 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are -ligh efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1) 26w Compact Fluorescent Triple 4 Pin Yes X No 37.0 x 12 = 444 or 60w Surface Mount Incandescent Yes I No IXL 60.0 x 2 = or 120 75w PAR 30 Yes I No IXI 75.0 x 4 = or 300 Yes I No x = or Yes No I I x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No I I x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 444 B: 420 COMPLIES IF A _> B YES ® NO ❑ EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Paae:11 of 19 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Scherer Residence 9/18/2009 SYSTEM NAME FLOOR AREA Master Bedroom 1,379 SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Lalent I CFM I Sensible 699 1,7,115 2,220 473 17,602 0 2,455 1,998 0 0 103 3,503 2,123 103 4,740 0 0 2,455 1,998 25,528 4,343 26,338 Lennox XC14 / G60UHV (5 Ton) 49,490 0 60,000 Total Adjusted System Output a9,490 o so,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 66.8 OF 66.8 OF 105.0 OF O Supply Air Ducts Outside Air 103 cfm 104.1 of Supply Fan Heating Coil 2000 cfm ROOMS 70.0 of 69.1 of I :DOLING 11.0 / 77.6 of Outside er!—� 103 cfm 79.2/62.9 of Return Air Ducts 11 80.8 / 63.8 of 80.8/63.80F M 55.0/53.60F Supply Fan Cooling Coil 2000 cfm A:. n....4, Supply Air Ducts 56.2/54.1OF 42.1% R.H. ROOMS 78.0 / 62.5 of L EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page: 12 of 19 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Scherer Residence 9/18/2009 SYSTEM NAME FLOOR AREA Guest Bedroom 462 Fmr.imFFRwr. [_HFCKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 36,000 Total Output (Btuh) 36,000 Output (Btuhlsgft) 77.9 Cooling System Output per System 23,400 Total Output (Btuh) 23,400 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 50.6 Total Output (sgft/Ton) 236.9 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sqft) 1.73 Airflow (cfm/Ton) 410.3 Outside Air (%) 4.3 Outside Air (cfmisqft) 0.08 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airs 26.0 OF 67.0 OF 67.0 OF Outside Air 35 cfm 68.9 of 11.0 / 77.6 of Outside �� 35 cfm 79.6/63.2 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 384 9,390 1,276 223 8,314 0 1,347 944 0 0 35 1,158 694 35 1,582 0 0 1,347 944 13,24 1,970 11,783 Lennox XC14 / G60UHV (2 Ton) 16,374 4,168 36,000 Total Adjusted System Output16,37a a,168 36,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am ream Temperatures at Time of Heatina Peak) 1105.00F Supply Fan Heating Coil 800 cfm �% Return Air Ducts � 80.9 / 63.9 of 80.9 / 63.9 of 55.0 / 53.6 of 0 Supply Fan Cooling Coil 800 cfm h Return Air Ducts 'I Supply Air Ducts 103.9 of ROOMS 70.0 of I Supply Air Ducts 56.6/54.3OF 426% R.H. ROOMS 78.0 / 62.7 of i EnergvPro 4.4 by EnergySoft User Number: 7403 Job Number: Page: 13 of 19 1 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Scherer Residence 9/18/2009 SYSTEM NAME FLOOR AREA Living 2,801 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 2 Heating System Output per System 60,000 Total Output (Btuh) 120,000 Output (Btuhlsgft) 42.8 Cooling System Output per System 56,500 Total Output (Btuh) 113,000 Total Output (Tons) 9.4 Total Output (Btuh/sqft) 40.3 Total Output (sgft/Ton) 297.5 Air System CFM per System 2,000 Airflow (cfm) 4,000 Airflow (cfmisqft) 1.43 Airflow (cfm/Ton) 424.8 Outside Air (%) 5.3 Outside Air (cfm/sqft) 0.07 Note: values above given at ARI conditions 26.0 of 66.6 of Outside Air 210 cfm Supply Fan 4000 cfm 68.9 of 11.0 / 77.6 of 311 , Outside Air 210 cfm 79.2/62.90F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,477 36,158 3,685 1,112 41,420 0 5,186 4,702 0 0 210 7,101 4,358 210 9,590 0 0 5,186 4,702 53,632 8,043 60,414 Lennox XC14 / G60UHV (5 Ton) 98,929 0 120,000 Total Adjusted System Output 98 929 0 120,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am RICS (Airstream Temperatures at 66.6 of ® 105.0 of Heating Coil f% Return Air Ducts Y 80.9 / 63.7 of 80.9 / 63.8 of55.0 / 53.6 of - �_ 11 Supply Fan 4000 cfm Cooling Coil Time h Return Air Ducts '4 Supply Air Ducts 103.9 OF ROOMS 70.0 of Supply Air Ducts 56.2 / 54.1 of 41.8% R.H. ROOMS 78.0/62.4OF EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:14 of 19 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Scherer Residence 9/18/2009 SYSTEM NAME FLOOR AREA Office 450 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 36,000 Total Output (Btuh) 36,000 Output (Btuh/sqft) 80.0 Cooling System Output per System 23,400 Total Output (Btuh) 23,400 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 52.0 Total Output (sgftrron) 230.8 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sqft) 1.78 Airflow (cfm/Ton) 410.3 Outside Air (%) 4.2 Outside Air (cfm/sgft) 0.08 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent I CFM I Sensible 321 7,864 1,263 169 6,295 0 1,128 715 0 0 34 1,137 675 34 1,550 0 0 1,128 715 11,255:7:[::::::;;38 9,274 Lennox XC14 / G60UHV (2 Ton) 16,216 4,297 36,000 Total Adjusted System Output 1x,216 x,297 36,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 67.3 of 67.3 of 105.0 of O .4 F Supply Air Ducts Outside Air 34 cfm Supply Fan Heating Coil 104.2 of 800 cfm. ROOMS 70.0 OF 69.2 of t OOLING S 11.0 / 77.6 of outside Air — I 34 cfm 79.3/63.10F �% Return Air Ducts `i 80.7 / 63.8 of 80.7 / 63.9 of 55.0 / 53.6 of Supply Fan 800 cfm Cooling Coil h Return Air Ducts `S Supply Air Ducts 56.3/54.2OF 426% R.H. ROOMS 78.0 / 62.7 of EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:15 of 19 ROOM LOAD SUMMARY PROJECT NAME Scherer Residence DATE 9/18/2009 SYSTEM NAME Master Bedroom FLOOR AREA 1,379 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult, CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone #1 Master Bedroom 1 699 17,115 2,220 699 17,115 2,220 473 17,602 PAGE TOTAL 699 17,115 2,220 473 17,602 TOTAL 699 17,115 2,220 473 17,602 EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page: 16 of 19 ROOM LOAD SUMMARY PROJECT NAME Scherer Residence DATE 9/18/2009 SYSTEM NAME Guest Bedroom FLOOR AREA 462 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone #2 Guest Bedroom 1 384 9,390 1,276 384 9,390 1,276 223 8,314 PAGE TOTAL 1 384 9,390 1,276 223 8,314 TOTAL 1 384 9,390: 1,276 223 8,314 EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page: 17 of 19 J ROOM LOAD SUMMARY PROJECT NAME Scherer Residence DATE 9/18/2009 SYSTEM NAME Living FLOOR AREA 2,801 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone #3 Living 1 1,477 36,158 3,685 1,477 36,158 3,685 1,112 41,420 PAGE TOTAL 1 1,477 36,158 3,685 1,112 41,420 TOTAL 1,477 36,158 3,685 1,112 41,420 EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page: 18 of 19 BROOM LOAD SUMMARY PROJECT NAME DATE Scherer Residence 9/18/2009 SYSTEM NAME FLOOR AREA Office 450 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone #4 Office 1 321 7,864 1,263 321 7,864 1,263 169 6,295 I PAGE TOTAL 1 321 7,864 1,263 169 6,295 TOTAL 321 7,864 1,263 169 6,295 EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:19 of 19