Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-1860 (SFD)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T`ht 4 4 a" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/03/06 Application Number: x:05-="00003860 Property Address: 53264 VIA PISA APN: 772-500-055- - - 'Application description: DWELLING - SINGLE FAMILY Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 517376 Owner: CAM & JEFF BARNES 52 EUCALYPTUS DETACHED TIBURON, CA 94920 Contractor: Applicant: Architect or Engineer: GOLDEN CONSTRUCTION INC, PAUL 73710 FRED WARING DR STE 101 PALM DESERT, CA 92260' (760)776-4215 -- Lic. No.: 786919 11D MAR 10 2006 -- --------=-------------------------------------------------------------------------- - ------ LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATIONCITY OF LA QUWTA I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: FINANCE DEPT. Section 7000) of Division 3 of th2!7 and Professionals Code, Dnd License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for wore c e License Class: B Li ns 786919 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is �"(s / issued. Dat9l 0_10 Contractor ,/ _ � I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _ 1 I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0013325-2006 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so to become subject to the workers' compensation laws of California, and agree that, if I uld come subject to the workers' compensation provisions of Section % !q 3700 of the Lab9 Code, shall f [hwith/co%�pl i[h Dse provisions. pplicant: 4 WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that th ov information is correct. I agree to comply with all city and county ordinances and state laws relating to ilding c struction, and here authorize representatives of this county to enter u on the above-mentioned p operty fo ns/c/�ttpn pur s at �t' Are Signature (Applicant or Agent)ill / - 41, t Application Number . . . . 05-00001860 i Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 2093.50 Plan Check Fee 1360.78 Issue Date . . . . Valuation . . . . 517376 Expiration Date 8/30/06 Qty Unit Charge Per Extension BASE FEE 2039.50 18.00 ---------------------------------------------------------------------------- 3.0000 THOU BLDG 500,001-1,000,000 54.00 Permit ELEC-NEW RESIDENTIAL Additional desc . Permit Fee. 257.08 Plan Check Fee 64.27 Issue Date . . . . Valuation . . . . 0 Expiration Date 8/30/06 _ Qty Unit Charge Per Extension BASE FEE 15.00 6040.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 211.40 784.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 15.68 1.00 ---------------------------------------------------------------------------- 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation 0 Expiration Date 8/30/06 Qty Unit Charge Per - Extension ---------- ----------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 139.00 Plan Check Fee 34.75 Issue Date . . . . Valuation 0 Expiration Date 8/30/06 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36.00 4.00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 7.00 6.5000 EA MECH VENT FAN 45.50 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 LQPERMIT rr Application Number . . . . . 05-00001860 Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 207.00 Plan Check Fee 51:75 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/30/06 Qty Unit Charge Per Extension BASE FEE 15.00 22.00 6.0000 EA PLB FIXTURE 132.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 16.00 .7500 EA PLB GAS PIPE >=5 12.00 1.00 15.0000 EA PLB GAS METER 15.00 ----------------------------------------------------------------------'------ Special Notes and Comments 6040 sq. ft. SFD.THIS PERMIT DOES NOT INCLUDE POOL & SPA BLOCK WALLS OR DRIVEWAY APPROACH:March 3, 2006 2:05:32 PM jjohnson ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 793.44 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 480.00 ENERGY REVIEW FEE 136.08 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE 15.00 DIF'LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 51.73 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1666.00 Fee summary Charged Paid Credited Due --------------------------- Permit Fee Total ------------------------------ 2711.58 .00 .00 2711.58 Plan Check Total 1511.55 750.00 .00 761.55 Other Fee Total 4692.25 .00 .00 4692.25 Grand Total 8915.38 750.00 .00 8165.38 LQPERMIT . �Yy T, r , v Building Address ' Owner V4/ P.O. BOX 1504 APPLICATION ONLY CALLS O QUINTA, CALIFORNIA 92253 Address Z C,4 City > Zip TO_ /0'a VA -a -L tractor r Address _ ! ,c4 D ir/►�/4 2��G D %?. � f p/ /qty_ Zip ; Tel --I / G� Cif- .S!`•�% ,Z2 % % State Li c. GI & Classif. Lic: Arch., Engr. Desiqner raoress •IeL__� City. Zips State--' Lic -# LICENSED CONTRACTOR'S DECLARATION I reby affirm that I am licensed under provisions of Chapter 9 (commencing with Section ,\1,..b 00 of Division 3 of the Business and Professions Code, and my license is in full force an � OWNER -BUILDER DECLARATION I here affirm that I am exempt from the Contractor's License Law for the f lowing reason: (Se 7031.5, Business and Professions Code: Any city or county which r quires a permit to con truct, alter, improve, demolish, or repair any structure, prior to its iss ante also requires the a licant for such permit to file a signed statement that he is license pursuant to the provisions the Contractor's License Law, Chapter 9 (commencing with Se tion 7000) of Division 3 of the usiness and Professions Code, or that Pe is exempt therelro ,and the basis for the alleged ex prion. Any violation of Section 7031.5 by any applicant for permit subjects the applicant to a 'vil penalty of not more than live hundred dollars ($500). O I, as owner of the roperty, army employees with wages as their sole c pensa"on, will do the work, and the str lure is not intended or offered for sale. (Sec. 7044, usiness and Profes- sions Code: The Cont ctor's Lice. Law does not apply to an owner property who builds or improves thereon an who does such work himself or through his o employees, provided that such improvement re not intended or offered for sale. If, how ver, the building or im- provement is sold within ne year of completion, the owner-builde will have the burden of proving that he did not bu or improve for the purpose of sale). ❑ I, as owner of the propert am exclusively contracting with lice ed contractors to construct the project. (Sec. 7044, Bus ass and Professions Code: The C tractor's License Law does not apply to an owner of prop who builds or improves there , and who contracts for such projects with a contractors) li nsed pursuant to the Contract is License Law) ❑ 1 am exempt under Sec. B. & P.C. for this re son WORKER'S C MPENSATIO DECLARATION I hereby affirm that I have a certitic a of copse to self -insure, or a certificate of Worker's Compensation Insurance, or a certified c py ther f. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certifie py is hereby furnished. CERTIFI/othe \fowhich N FROM WORKERSNSURANCE (This section need not be completerne hundred dollars ($100) valuation or less). I certify that in the performancothispermit is issued, I shall not employ any person in any manner sot to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after aking this Certificate Exemption you should become subject to the Workers' Compe sation Provisions of the abor Code, you must forthwith comply with such provisions or is permit shall be deemed r oked. ONSTRUCTION LENDING AGENC I hereby affirm that t re is a construction lending agency forth performance of the work for which this permit is i ued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a build' g permit when properly filled out, signed and va\relati ubject to expiration if work ereunder is suspended for 180 days. I certify th I have read this application and state that the abovcorrect. I agree to co ply with all city and county ordinances and state lbuilding construction nd hereby authorize representatives of this city to enentioned property for nspection purposes. Signatur of applicant Date Mailin Address City, tate, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CONST. �1 OCC. GRP. A.P.'Number J 2« ✓ 600- aE, Legal' Description Project_Description ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE Sq.: Ft: // Size' b� O Y0 No. No. Dw. Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep." -- Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure I JUN f,lN AF TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE r "'ti . Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name:Jeff Barnes (Resi� denee@.Hideaway) Date: March 8, 2006 Owner's Name: Jeff Barnes Phone No. (760) 776-4215 Project Address: 53-264 Via Pisa, La Quinta, CA Project Description: Single Family Dwellings APN: 772-500-055 Tract #: Lot #'s: Type of Development: Residential XX! Commercial Industrial Total Square Feet of Building Area: 6,040 sq. Ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is aut ze to sign on behalf of the owner/developer. Dated: 03/08/06 6/z.Signature: � *********************************************************************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 6,040 sq. ft. Amount per Sq.Ft. $ 2.88 Amount Collected $ 17, 395.20 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: Leticia C. Torres, Facilities Clerk Signature NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEND STATEMENT Of FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this Dis�trrt provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. 1V:c:mydr..c� �cvfcis;ci+rtitic:aii of C mlpliancc fnnu tables -r,() USP:.doc 1/16/03 T VDELITY NATIONALTITLI� COPVII�ANY DOC it*9 e020OZ F•00 X676 ..,jUnIVISION DEPARTMTNT Page t of 4 Doe T Tax Paid Recorded In Official Records County of Riverside WHEN RECORDED MAIL TO: Gary L. Oreo Assessor, County Clerk b Recorder .Jeffrey & Cam Barnes 32 Eucalyptus BelvedereTiburona CA 94920 1 111111 Illlil Illi II IIII ILII IIIII! IIIIiI III Illllllllilll MAIL TAX STATEMENT TO: SAME AS ABOVE ©©ei�oov�o� mom DOCUMENT TRANSFER TAX S 374.55 XX Computed on the consideration or value of property conveyed; OR lL9 Computed on the consideration or value less liens or encumbrances LKjWT remaining at the time of sale. n Signature of Declarant or Agent determining tax — Firm Name *0. DUP GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is herdby'acknowledged, ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company ("Grantor"), hereby GRANT(S)to JEFFREY BARNES AND CAM BARNES, HUSBAND AND WIFE AS COMMUNITY PROPERTY ("Grantee"), the real property located in -the City of La Quinta, County of Riverside, State of California, described as: See Legal Description attached hereto and incorporated herein as Exhibit "A SUBJECT TO all matters of record including, without limitation, the covenants and agreements described in Exhibit "A" attached hereto. Dated: January 20, 2003 l-LA/627969.1 1 ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company By: Nationwide Realty Investors, Ltd., an Ohio limited liability company its managing meter By: _ opt ' . /��G , Joseph L. Arenson Authorized,Representative ... Pix Pr 0 F ' 'v' 2.`'G.G��v'�►r+y`.-„+�4.sr'..:'"1w''. '�.r"�... �.+++',;,,.���.,..r'�,,,'�a..P`,'3'0+`'�..�'".��r,c .Y"°�.n"'.�`h � l+e'� '1iYr.'!' �VrP' �,Y' .+" .�,re irrr,.N' �I....P .Ar j/”" +`t►• r "++Y EFF, BARNES' iz�o:%s- .. "� ..CAM.BARNES .:;. iw`..► "053935409 ,• +: r �,`+ +ear 32, EUCALYPTUS.-- UCALYPTUS.--BELVEDERE BELVEDERE'CA'•94920 � u .r.�:Yw"` rDnAT'E T t/ �„� •. _,,f*" -Vol '�/+ ih�'-? 'a+!"�•N�'��_ «+�.;'*y' �+�r,Iw "'} �P^' 1_rw yam'!01 ��`'►.+�J��, ar'�.-�'LA. "�`+n�f - .A•�r�;`�'"'R��A"�..� "'P-�...I�^'f:. Q-rr �j /�j��... i PAY TO THE `�� a D! r . ;,. "" I 1 ORDER OF "` V71 _ ., •rc.-�.. _ +r _ f. _. °^ �M✓.�'I l� �C./.. a�, . '.,-': "so.rrr'.." "�u^�ewd•,..,✓.. 'xf :,,"''yrr•',hrki��s'tx"°►'.�- . ' _"•`.s,r*,�. is Fargo Bank NAl' ^iwrw�,w,,e,.l,,l�sf'a�rg� r,'�. .wCustomer.,fiy,�•.+� � +'�}Fd"0 �iw.s�, teti,»,�e1►'" `�+'"',.�",'.. Celfornia+.i- r,'s;w;G o- r► om. ,",Sinie � 1989 �^*��;,x � �.��,, .��,, •r" r�.',�,R,,i.�•��„°,¢,g�: j li y. "`�.V"�y.w�M! wn- �Fyi�,�f4r .y '4"y�,V 1' fit. 4• fd'�}',�. �i f41e V'.%Z'�I'^ O +,:+1:240!,'2 021:O�S;3'3 3,S 40T211'^ 24'6�L' ��'00000�7 5000:x'. ♦' + �+►r.-r. �'r►�r+..+.i:! ,4 `� ��•►�.�'..r."':.a+.-`s'e...�/+'�;�t y�'�+c.'.�` w� 4A`"�w.. i� w :+e'er` ��r' 'eP 7 4 - 7 r F �. ! .SOF �T�w• O -,, N M a 2 in y�+ ai $y°�''c�^ .fr�ift.$Y'' G' . f'��,6: 4110 .0 04 All- aia 41 t. c° man m a I. � ®d n �arm' 0$/09/2,005 e@2:08 750'�469KS i:ESERT RE GIRT I+UNT FA` t C,_' �G� H I D. E AWA Y OWNERS ASSOCIAT.iQiv .May '23, 2005 S. Harrison Architectural. Design 24 Upper Road NATest Ross, CSA 94957 RE: Barnes/Finul Working Drawings #2 & Meeting with Owners Lot 303 at 53264 Via Pisa Dear li t. Harrison: The Hideaway resign. Review Committee appreciates the time NIr, and. Mn. Barnes took to discuss the Final 'Working Drawings submitted for Lot'303. The DRC is providing you with a `Conditional.' approval of tine Final Working Drawings so your plans may be submitted to the City of La, Quirtaa for plain check. The DRC will also accommodate the scheduling of a P.re-remeeting at, the lot, however construction may MOT commence until the COMments listed on the attached page are resolved as well as the Design Guidelines requirement that a licensed architect/landscape architect prepare (sta.rznp) the Final Working Drawings. Please call Brook Marshall at (760) 346-1161 with any questions. Sincerely, Hideaway Design Rmiew Commjtt�ee cc: Mr. and Mrs. Hamm arty: r��e DESER'r RESOPT MANAGEENIENT roST cF?'.C:i DUX 4772 i P: LIM DESERT, :i-j§O A!.FSSAwhAO: i'i)•`�Nc 7�0.?�.ii.11lil� FAX 7G;�,346.ngs3t3.ScpCL:�Trnf; zl').il•E.t'1w'.^ YOUNG ENGINEERING SERVICES +Engineering +Architecture•Surveying• Building&, Safety Services Letter - of Transmittal To: City of La Quinta Date: 02-06-06 Project: 53-364 Via Pisa Attn: Ed Randall PC#: 05-1860 Tel No.: (760). 7777012 Tract No.: We are forwarding: By Messenger By Mail Your Pickup No. oj'Copies Description. 1 Redlined Plans 1 Redlined Struct 1 Revised plans 1 Revised Struct 1 Truss 1 Soils Report Comments: Structural contents are approvable Thank You. This Material Sent for: Your Files Per Your Request Your Review x Approval Checking At the request of: Other By, Win P@chunuri Phone # (760) 360.5770 EXT. 108 77-804 Wildcat Drive, Suite C, Palm Desert, CA 92211 (760) 360-5770 Bronz Young Z0 39dd 3S 9NIN33NI9N3 9NnOA 6US09609L Lt :Lt 9002/90/Z0 y:0j,,Certificato of Occupancyoo U'KOA g . C� OF'iBuildin & Safet Department 9► Y p This Certificate is issued pursuant to the requirements of Section 109 of the California Building .: Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 53-264 VIA PISA Use classification: SINGLE FAMILY DWELLING Building Permit No.: 05-1860 Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL Owner of Building: CAM & JEFF BARNES Address: 52 EUCALYPTUS City, ST, ZIP: TIBURON, CA 94920 By: EDDIE MUIR Date: APRIL 5, 2007 Building Official POST IN A CONSPICUOUS PLACE • .,. -+ ':y .'. �... - .. , -IVY.- r^' w T'x'+9^•."=f.,C a.:.+M ..+..r -. .roc-=^ t _.^ n r - - _ _-.,.. t l I . TITLE 24 REPORT I Title 24 Report for: Lot #303 53-264 Via Pisa La Quinta, CA 92253 Project Designer: S. Harrison Architectural Design 24 Upper Road West Ross, CA 94957 (415) 456-6705 Report Prepared By: CJ McFadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 Job Number: CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DAT 6 BY 58— Date: °PFtLe C-101py 2/16/2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. I EnergyPro 3.1 By EnergySoft Job Number. User Number. 3665 TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 6 Form C -2R .Computer Method Summary 8 Form ENV -3 Proposed Construction Assembly 15 HVAC System Heating and Cooling Loads Summary 16 Room Load Summary 19 Room Heating Peak Loads 22 Room Cooling Peak Loads 25 r EnergyPro 3.1 By Energysoft Job Number: User Number: 3665 1 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Lot #303 2/16/2006 Project Title Date 53-264 Via Pisa La Quinta Project Address Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Check Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 6,040 ft2 Average Ceiling Height: 11.2 ft Total Conditioned Slab Area: 6,040 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 0 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component R-38 Roof(R.38.2x14.16) R-21 Wall (W.21.2x6.16) Slab On Grade Slab On Grade Solid Wood Door FENESTRATION Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) Wood 0.026 Exterior Roof Wood 0.057 Exterior Wall n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Wood 0.387 Exterior Door Shadinq Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Left (East) 309.1 0.50 0.29 Bug Screen ❑ X❑ ❑ x❑ Left (East) 80.0 0.50 0.29 Bug Screen 0 ❑ ❑ X❑ Rear (South) 208.0 0.50 0.29 Bug Screen x❑ ❑ ❑X❑ Rear (South) 151.1 0.50 0.29 Buq Screen ❑ X❑ ❑ ❑X Right (West) 387.4 0.50 0.29 Bug Screen ❑ X❑ ❑ X❑ Front (North) 263.2 0.50 0.29 Bug Screen ❑X❑ ❑X❑ Right (West) 168.0 0.50 0.29 Bug ScreenX❑ ❑ ❑X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 02/16/06 10:30:35 Run Code: 1140107435 Ener Pro 3.1 B Ener Soft User Number. 3665 Job Number: Pa e:3 of 32 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Lot #303 Project Title 2/16/2006 Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments ('antral Fiirnaca 80% AFUE Ducts in Attic 4.2 Setback HVAC #1 Central Eumace 80% AFUE Ducts in Attic 42 Sethack HVAC #2 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC #3 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 42 Sethack HVAC #1 Split Air Conditioner 14.O�F RR Ducts in Attic 42 Sethack HVAC #2 Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC #3 WATER HEATING SYSTEMS Rated 1 Tank Energy Fact*1 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.0 -Smith FGR -75 Large Gas Recircfrime+Temp 2— 76,000 75 0.72 0.0000 0.0 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: S. Harrison Architectural Design Address: 24 UDDer Road West Ross, CA 94957 Telephone: (415) 456-6705 Lic. #: 33 a (signs ure) (date) Enforctement Agency Name: Title/Firm: Address: Telephone: Name: CJ McFadden Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 (signature) date) IEnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:4 of 32 1 Certificate of Compliance: Residential (Addendum) CF -1 R Lot #303 2/16/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 3ased on the adequacy of the special justification and documentation submitted. Plan Field The HVAC System "HVAC #1 " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. The HVAC System "HVAC #2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. The HVAC Svstem "HVAC #3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC #1 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. I EneravPro 3.1 By EnergvSoft User Number. 3665 Job Number. Page:5 of 32 1 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ❑X '§150(a): Minimum R-19 ceiling insulation. § 150(b): Loose fill insulation manufacturer's labeled R -Value. + 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does X§ not apply to exterior mass walls). 0'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. . ❑X § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. a§1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:6 of 32 Mandatory Measures Checklist: Residential (Page 2 -of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (") may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) F'§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. FV §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3,1 By EnergySoft User Number: 3665 Job Number. Page:7 of 32 Computer Method Summary (Part 1 of 3) C -2R l ro) 3 Root 1600 —0-02-6- _345. 2/1612096 Project Title X ❑ Date -5 3--26A-Via-Pi ❑ Wall— 16119.057- —27-0 —9.0- 0Wall— Project Address -Wall 287 —0-057- 90 IX Building Permit # B_EZ 7F AIEZCOND1Z ORING' 1X (760) 346-0855 Wall_ 955 —0-05L 90 90 Documentation Author ❑ Telephone plan Check/Date Comp_U.ter Pelfol_Rlance Wall 6.56_ —0.0.5- —270 9.0 15 ❑ Field Check/Date Compliance Method (Package or Computer) ❑ Climate Zone IX Source Energy Use Standard Proposed Compliance ❑ (kBtu/sf-yr) Design Design Margin Wall— 379 0.057 X80. 90_ Space Heating 4.50 5.89 -1.39 iX Space Cooling 38.31 37.92 0.39 ❑ Domestic Hot Water 4.72 3.44 1.27 Totals 47.54 47.26 0.28 Percent better than Standard: 0.6% Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name 6,040 ft2 Single Fam Detached (North) 0 deg 1.00 1 Floor Area Volume Floor Construction Type: ❑ Raised Floor X❑ Slab Floor Total Fenestration Area: 25.9% Total Conditioned Volume: 67,690 ft 3 Total Conditioned Slab Area: 6,040 ft 2 # of Units 1i 1 1 600 1-6,0.0.0 —0-26- -H #2 14-45 —.3240 _0_6.0_ kLVAG #3 796 --7-950 _0.13_ Solar OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y / N Root 1600 —0-02-6- _345. Wall— 325 0 o.5.7- 90 —90 X ❑ Wall_ 312 —0-057- x.80- 90_ _ ❑ Wall— 16119.057- —27-0 —9.0- 0Wall— -Wall 287 —0-057- 90 IX ❑ Roof _3.645 0..026_ —345 0_ 1X ❑ Wall_ 955 —0-05L 90 90 IN ❑ Wall— 630 9.057- —180 9Q IN ❑ Wall 6.56_ —0.0.5- —270 9.0 IX ❑ Wall— —7-31 —0.05.7- 0 _90 ❑ Door 24 —0-387- 0 90 IX ❑ Roof X95 —0-06- 34.5 0 LX ❑ Wall_ 301 _0_0.57- 90 90 1X ❑ Wall— 379 0.057 X80. 90_ X ❑ Wall— x.63.9 057 270 90_ iX F- Wall_ 3Z5 _0_0.57- 0 90 -Wall IX ❑ Form 3 Reference _11:38 BooL(R.38.2x1416) R21 W..alL(YV.2L2x6 1-6) R21 VWalL(YV_2 -2x6.16) —R--ZL LaIL(1N_.2L2x6.16) .17-21 VWal l_( -W 21.2x6.] 6) R_3.8-RooQR38.2x14.16.) R_21 WaIL(Y1L21_.2x616) R-2:1-Wall-(-W-21-W, R21 VYalL(W.21.2x6.16.) R21 VWaIL(_W..21_2x6.16.) -Solid-Wood-Door _Fz38Boo.L(1338..2x1416) R-21 Wall (W.21.2x6.16) R-21 WaIL(.W 21.2x616.) _&21 W-alL(_W.2L2x6..16.) R21-Wall_(W-212x6 Zone Type C.onditioned— Conditioned— Conditioned— ZONE #1 ZONE#1 .ZONF 9 .ZONF # ZONF #2 .ZO.NE#2 ZONE#9 ZONF #2 ZONE#3 .ZONE#3 7 -ONE -#3 ZONE13 ZONE#3 Thermostat Vent Type Hgt. Area —Setback— —2 —nLa _S.etback— n/a _S.etback— —nLa Location / Comments EnergyPro 3.1 By Energysoft User Number. 3665 Job Number. Page:8 of 32 Comouter Method Summary (Part 2 of 3) C -2R Lot #303 2/16/2006 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # TVDe Area Factor SHGC Azm. Tilt Comments -I- Window --Left (East)_ X0_0 0_.5.00_ -0.22 90_ _9.Q Marvin -Windows -ZONE-k1 2 Window Left East 40.0 0.500 0.29 90 90 Marvin Windows ZONE #1 3 Window Left East 40.0 0.500 0.29 90 90 Marvin Windows ZONE #1 4 Window Left (East) 40.0 0.500 0.29 90 90 Marvin Windows ZONE #1 5 Window Rear (South) 28.0 0.500 0.29 180 90 Marvin Windows ZONE #1 6 Window Rear South 5.9 0.500 0.29 180 90 Marvin Windows ZONE #1 7 Win ow Rear ---(South 28.0_ 0.500 0.29 180_ 90 Marvin Windows ZONE #1 8 Window Rear (South) 5.9 0.500 0.29 180 90 Marvin Windows ZONE #1 6 Window Ri bt-_(Westj 12.5 0,5Q0 0.29- 270�9 Marvin Windows ZONE #1 10_ Window Riaht Westj 12.0 0.500 0.29 270 90 Marvin Windows ZONE #1 11 Window Right West _ 4.0 0.500 0.29 270 90 Marvin Windows ZONE #1 12 Window Right (Westj 4.0 0.500 0.29 270 90 Marvin Windows ZONE #1 13 Window Riaht_(W__est� --6-0- 0-500 --OM _27_0_ ---qQ Marvin_Wiado:ws ZONE #1 14 Window Right (West) 20.0 0.500 0.29 270 90 Marvin Windows ZONE #1 15 Window Right _(West)_ 5.0 0.500 0.29 270 90 Marvin Windows ZONE #1 16 Window Front (North) 8.0 0.500 0.29 0 90 Marvin Windows ZONE #1 17 Window Front North 25.0 0.500 0.29 0 90 Marvin Windows ZONE #1 18 Window Left East 15.0 0.500 0.29 90 90 Marvin Windows ZONE #2 19 Window Left (Eat 24. _ 0.500 0.29 �� 90 Marvin Windows ZONE #2 20 Window Left -(92-sltl 15.0 0.500 0.29 90 90 Marvin Windows ZONE #2 21 Window Left (East) 15.0 0.500 0.29 90 90 Marvin Windows ZONE #2 22. Window Left (East) 20.0 0.500 0.29 90 90 Marvin Windows ZONE #2 23 Window Left (East) 20.0 0.500 0.29 90 90 Marvin Windows ZONE #2 24 Window Left East 15.0 0.500 0.29 90 90 Marvin Windows ZONE #2 25 Window Left East _ 15.0 0.500 0.29 90 90 Marvin Windows ZONE #2 26 Window Left East 5.4 0.500 0.29 90 90 Marvin Windows ZONE #2 27 Window Left (East) 5.4 0.500 0.29 90 90 Marvin Windows ZONE #2 28 Window Left (East) 5.4 0.500 0.29 90 90 Marvin Windows ZONE #2 29 Window Left (East) 20.0 0.500 0.29 90 90 Marvin Windows ZONE #2 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 8.0 5.0 10.0 0.1 10.0 10.0 4 Bug Screen 0.76 8.0 5.0 10.0 0.1 10.0 10.0 5 Bug Screen 0.76 8.0 3.5 8.0 0.1 8.0 8.0 6 Bug Screen 0.76 7 Bug Screen 0.76 8.0 3.5 8.0 0.1 8.0 8.0 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 EnerovPro 3.1 By EnerovSoft User Number: 3665 Job Number: Page:9 of 32 1 Computer Method Summary (Part 2 of 3) C -2R Lot #303 2/16/2006 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments 10. Wiadow Lett (East)_ -20.0 0.50.0 0 29 9.0 _90. Marvin_WJndowS -M-NF #2 31 Window Rear (South) 28.0 0.500 0.29 180 90 Marvin Windows ZONE #2 32 Window Rear (South) 5.9 0.500 0.29 180 90 Marvin Windows ZONE #2 33 Window Rear South 28.0 0.500 0.29 180 90 Marvin Windows ZONE #2 34 Window Rear South 5.9 0.500 0.29 180 90 Marvin Windows ZONE #2 35 Window Rear South 48.0 0.500 0.29 180 90 Marvin Windows ZONE #2 36 Win ow Rear ---(South) 5.4 0,59Q 0.29 180 90 Marvin Wind2s ZONE #2 37 Window Rear (South) 48.0 0.500 0.29 180 90 Marvin Windows ZONE #2 -3-8 Win Qw Rear (off 5.4 0599_ 0.29 180 90 Marvin Windows ZONE#2 -a9 Win ow Rear ut 5.4 0.500 0.29 180 90 Marvin Windows ZONE #2 A0 Window Rear (South) 40.0 0.500 0.29 180 90 Marvin Windows ZONE #2 41 Window Right (West)_ 168.0 0.500 0.29 270 90 Marvin Windows ZONE #2 _42, Wiadow-Right (_W_est). _5 4 0-500 0 29 _2.7-0_ 90 Maotin_Windows ZONE12 43 Window Right West 5.4 0.500 0.29 270 90 Marvin Windows ZONE #2 44 Window Right (West)_ 5.4 0.500 0.29 270 90 Marvin Windows ZONE #2 45 Window Right West 44.0 0.500 0.29 270 90 Marvin Windows ZONE #2 46 Window RightWest _ 9.2 0.500 0.29 270 90 Marvin Windows ZONE #2 47 Window Right (West) 48.0 0.500 0.29 270 90 Marvin Windows ZONE #2 $ in _ w Ri ht (West). 10.0 0.500 0.29 270 90 Marvin Windows ZONE #2 49 Window Right West 48.0 0.500 0.29 270 90 Marvin Windows ZONE #2 50 Window Right (West) 10.0 0.500 0.29 270 90 Marvin Windows ZONE #2 5j_ Window Right est) 44.0 0.500 0.29 270 90 Marvin Windows ZONE #2 52 Window Right (West) 9.2 0.500 0.29 270 90 Marvin Windows ZONE #2 53 Window Right (West) 12.5 0.500 0.29 270 90 Marvin Windows ZONE #2 54 Window Front (North) 40.0 0.500 0.29 0 90 Marvin Windows ZONE #2 55 Window Front(North) 10.0 0.500 0.29 0 90 Marvin Windows ZONE #2 56 Window Front (North) 5.4 0.500 0.29 0 90 Marvin Windows ZONE #2 57 Window Front (North) 40.0 0.500 0.29 0 90 Marvin Windows ZONE #2 58 Window Front North. 10.0 0.500 0.29 0 90 Marvin Windows ZONE #2 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 31 Biu Screen 0.76 8.0 3.5 8.0 0.1 8.0 8.0 32 Bug Screen 0.76 33 Bug Screen 0.76 8.0 3.5 8.0 0.1 8.0 8.0 34 Bug Screen 0.76 35 Bug Screen 0.76 8.0 6.0 -1 -0 -01 100 100 36 Bug Screen 0.76 37 Bug Screen 0.76 8.0 6.0 10.0 0.1 10.0 10.0 38 Bug Screen 0.76 39 Bug Screen -dug 0.76 40 Screen 0.76 41 Bug Screen 0.76 8.0 21.0 10.0 0.1 10.0 10.0 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 Bug Screen 0.76 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 58 Bug Screen 0.76 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 10 of 32 1 Computer Method Summary (Part 2 of 3) C -2R Lot #303 2/16/2006 Project Title Date FENESTRATION SURFACES # Type Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. Area U- Factor SHGC Act. Azm. Tilt _59 Windoww Fsoni_(Nodb) -5.4 -0_50.0_ 0 29 0_ _9.0. 60 Window Front (North) 40.0 0.500 0.29 0 90 61 Window Front (North) 10.0 0.500 0.29 0 90 62 Window Front (North) 5.4 0.500 0.29 0 90 63 Window Front (North) 15.0 0.500 0.29 0 90 64 Window Front (North 15.0 0.500 0.29 0 90 65 Window Front (North) 4.0 0.50Q 0.29 0 90 66 Window Left (East) 12.5 0.500 0.29 90 90 67 Window Left (East)_ 21.4 0.500 0.29 99_ -90 68 Window Rear (South) 13.3 0.500_ 0.29 180 9Q 69 Window Rear (South) 48.0 0.500 0.29 180 90 70 Window Rear (South) 10.0 0.500 0.29 180 90 _7_1- WindoY Right (West). -2.1.4 -0,500- 0.29 -27_0_ 9Q 72 Window Right (West) 37.5 0.500 0.29 270 90 73 Window Right (West? 13.4 0.500 0.29 270 90 74 Window Front (North) 15.0 0.500 0.29 0 90 75 Window Front (North) 15.0 0.500 0.29 0 90 Glazing Type Manyin_Windows Marvin Windows Marvin Windows Marvin Windows Marvin Windows Marvin Windows Marvin Windows Marvin Windows Marvin Windows Marvin Windows Marvin Windows Marvin Windows M.antin-Windows Marvin Windows Marvin Windows Marvin Windows Marvin Windows Location/ Comments ZO.NF #2 ZONE #2 ZONE #2 ZONE #2 ZONE #2 ZONE #2 ZONE #2 ZONE #3 ZONE #3 ZONE #3 ZONE #3 ZONE #3 -ZONE #3 ZONE #3 ZONE #3 ZONE #3 ZONE #3 INTERIOR AND EXTERIOR SHADING Window Overhang_ Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 59 Bug Screen 0.76 60 Bug Screen 0.76 61 Bug Screen 0.76 62 Bug Screen 0.76 63 Bug Screen 0.76 Bug Screen 0.76 65 Bug Screen 0.76 66 Bug Screen 0.76 67 Bug Screen 0.76 68 Bug Screen 0.76 69 Bug Screen 0.76 70 Bug Screen 0.76 71 Bug Screen 0.76 72 Bug Screen 0.76 73 Bug Screen 0.76 74 Bug Screen 0.76 75 Bug Screen 0.76 EneravPro 3.1 By EneravSoft User Number: 3665 Job Number: Page: 11 of 32 1 Computer Method Summary (Part 3 of 3) C -2R Lot #303 Project Title 2/16/2006 Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sq (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES HVAC SYSTEMS Heating Equipment Minimum F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 19 0.76 0.0 0 ZONE #1 SI.ab_1?-erimeter t66 -076 _01Q 0 Z4N.E-#, Slab Perimeter 33 0.76 0_0 0 ZONE #2 Slab_Rerimeter _2.97- -Q.7-6 O -Q 0 ZQN.E E2 Slab-Rerimeter ---15 0.76 U 0 ZONE #3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments ntral Furnace 80° AFUE Ducts in tti-c 4.2 Setback HVAC #1 Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC #2 Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC #3 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC #1 Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC #2 Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC #3 WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution .# in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.O.Smith FGR -75 Large --Gas— Recirc/Time+Temp 2 76.,QQ075 0.72 0.0000 0.0 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 02/16/06 10:30:35 Run Code: 1140107435 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 12 of 32 Computer Method Summary (Part 3 of 3) C -2R Lot #303 2/16/2006 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments .Slab Perimeter 138 0.76 0. —0 ZONE #3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS, Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 02/16/06 10:30:35 Run Code: 1140107435 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 13 of 32 Computer Method Summary (Addendum) C -2R Lot #303 2/16/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement aqency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. Plan Field The HVAC System "HVAC #1 " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. The HVAC System "HVAC #2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. The HVAC System "HVAC #3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC #1 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 02/16/06 10:30:35 Run Code: 1140107435 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 14 of 32 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE Lot #303 1 2/16/2006 PONENT DESCRIPTION THICK- NESS 4MING (in.) ❑ 0.875 ❑ 0.010 ❑ 0.375 [X 5.500 ❑ 0.625 El El El R -VALUE DESCRIPTION WOOD FRAME R -VALUE ASSEMBLY NAME ASSEMBLY R-21 Wall W.21.2x6.16 Floor Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood TYPE (check one) Wall 5 Gypsum or Plaster Board lL W 7 Ceiling / Roof Ceiling 8 2.60 0 NFRAMING MATERIAL Wood 0.680 23.11 7.56 p z FRAMING% 15% Framing% 14.8 TOTAL HC 3 7 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) THICK- NESS 4MING (in.) ❑ 0.875 ❑ 0.010 ❑ 0.375 [X 5.500 ❑ 0.625 El El El R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.31 7 0.37 8 2.60 9 0.68 INSIDE SURFACE AIR FILM THICK- NESS 4MING (in.) ❑ 0.875 ❑ 0.010 ❑ 0.375 [X 5.500 ❑ 0.625 El El El R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.175 0.175 0.060 0.060 0.465 0.465 21.000 5.445 0.5621 0.562 0.31 2.63 0.37 0.98 2.60 0.26 0.68 0.6801 0.680 23.11 7.56 KC KT I]�MC *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0433 X 0.85 ] 8.46 0.20 1.69 0.06 0.35 0.02 1.06 0.29 0.31 2.63 0.37 0.98 2.60 0.26 0.68 14.8 TOTAL HC 3 7 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0433 X 0.85 ] + [ 0.1323 X 110.15 = 0.057 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE I EneravPro 3.1 By EnergvSoft User Number. 3665 Job Number: Page: 15 of 32 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Lot #303 2/16/2006 SYSTEM NAME FLOOR AREA HVAC #1 1,600 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM Sensible Latent 1, CFM I Sensible 1,755 33,990 4,394 704 28,387 0 1,700 1,419 0 0 120 4,575 2,508 120 5,874 0 0 1,700 1,419 41,964 6,9021 37,099 HS26-060/G40UH60C-110 (5) 46,714 5,610 89,400 Total Adjusted System Output 46,714 5,610 89,400 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 24.0°F 66.6°F Outside Air 120 cfm Heating Coil 69.3 OF Supply Fan 2000 cfm 108.0 OF -� Supply Air Ducts 107.4 OF ROOMS 70.0 OF h Return Air Ducts 'I (COOLING SYSTEM PSYCHROMETRICS (Airstream Temoeratures at Time of Coolina Peak) I 114.1 / 80.3 OF Outside Air 120 cfm 78.8/65.3 °F 80.9 / 66.1 OF . 59.3 / 57.9 OF Cooling Coil Supply Fa 2000 cfm 59.3 / 57.9 of Supply Air Ducts Fan 60.1 / 58.2 of 50.1% R.H. ROOMS 78.0 / 65.0 OF 1% Return Air Ducts 11 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 16 of 32 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Lot #303 2/16/2006 SYSTEM NAME FLOOR AREA HVAC #2 3,645 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 4,843 88,444 11,282 1,750 69,356 0 4,422 3,468 0 0 273 10,352 5,127 273 13,339 0 0 4,422 3,468 107,640 16,409 HS26-060/G40UH60C-110 (5) 92,247 13,750 Total Adjusted System Output 92,247 13,750 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm F777;:;31 178,800 178,800 Jan 12 am HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) I 24.0 OF, 66.1oF E 107.5 OF Outside Air 273 cfm 69.2 of 14.1 / 80.3 of Outside Air 273 cfm 79.0/66.0 of Heating Coil Supply Fan 4000 cfm 107.5 of Supply Air Ducts 106.7 of ROOMS 70.0 of 1% Return Air Ducts `i 81.4 / 66.8 of ■ 60.1 / 58.7 of Cooling Coil Supply Fa 4000 cfm 60.1 / 58.7 of —� Supply Air Ducts Fan 61.1 /59.1OF 52.2% R.H. ROOMS 78.0 / 65.7 of h Return Air Ducts `S EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:17 of 32 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY � PROJECT NAME DATE Lot #303 2/16/2006 SYSTEM NAME FLOOR AREA HVAC #3 795 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 54,100 Total Output (Btuh) 54,100 Output (Btuh/sqft) 68.1 Cooling System Output per System 36,000 Total Output (Btuh) 36,000 Total Output (Tons) 3.0 Total Output (Btuh/sgft) 45.3 Total Output (sgft/Ton) 265.0 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sqft) 1.51 Airflow (cfmrron) 400.0 Outside Air (%) 5.0 Outside Air (cfm/sgft) 0.08 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensible Latent CFM I Sensible 946 20,082 2,183 472 19,389 0 1,004 969 0 0 60 2,274 1,460 60 2,913 0 0 1,004 1 969 24,364 3,6431 24 241 HS26-036/G40UH36A-70X (3) 29,769 1,817 54,100 Total Adjusted System Output 29 769 1 817 54,100 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 24.0 of 67.0 of 108.8 of 108.8 of O Supply Air Ducts Outside Air 60 cfm 108.0 of Heating Coil Supply Fan 1200 cfm ROOMS 70.0 of 69.3 of 1 k Return Air Ducts `i (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolinq Peak) 14.1 / 80.3 of outside Air er—j 60 cfm 78.8/64.2 of 80.5 / 64.9 of 57.6 / 56.1 of Supply Fan 1200 cfm Cooling Coil 57.6 / 56.1 of Supply Air Ducts 58.3 / 56.4 of 46.5% R.H. ROOMS 78.0 / 64.0 of A Return Air Ducts 'i EnerovPro 3.1 By EneravSoft User Number. 3665 Job Number: Page: 18 of 32 1 ROOM LOAD SUMMARY PROJECT NAME Lot #303 DATE 2/16/2006 SYSTEM NAME HVAC #1 FLOOR AREA 1,600 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #1 Master Suite 1 1,755 33,990 4,394 1,755 33,990 4,394 704 28,387 PAGE TOTAL 1 11755 33,990 4,394 704 28,387 TOTAL 1 1,755 33,9901,- 4,394 704 28,387 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 19 of 32 ROOM LOAD SUMMARY PROJECT NAME Lot #303 DATE 2/16/2006 SYSTEM NAME HVAC #2 FLOOR AREA 3,645 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #2 Living Area 1 4,843 88,444 11,282 4,843 88,444 11,282 1,750 69,356 PAGE TOTAL 1 4,843 88,444 11,282 1,750 69,356 TOTAL 1 4,843 88,444 11,282 1,750 69,356 EnergyPro 3.1 By EnergySok User Number. 3665 Job Number: Page:20 of 32 ROOM LOAD SUMMARY PROJECT NAME Lot #303 DATE 2/16/2006 SYSTEM NAME HVAC #3 FLOOR AREA 795 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #3 Guest Room / Den 1 946 20,082 2,183 946 20,082 2,183 472 19,389 PAGE TOTAL 1 946 20,082 2,183 472 19,389 TOTAL 1 946 20,082 2,183 472 19,389 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 21 of 32 ROOM HEATING PEAK LOADS Project Title Date Lot #303 12/16/2006 Room Information Desian Conditions Room Name Master Suite Time of Peak Jan 12 am Floor Area 1,600 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Area LI -Value pT of Btu/hr .21.2x6.1 1600.0 x X X x X X x x X x x X X X X X X X x X x x x x X X x x X x X x x x x X x X X 0.0255 X x X X X X x x X X X x x X X X X X X X X X X X x X X x X x X x x X x X x X X 46.0 = = = = = = = = = = = = 1.879 1,535.2 0.0566 46.0 3,999 324.8 0.5000 46.0 7,470 perimeter = 185.0 45.5 8,418 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 21,7651 Infiltration: [ 1.001X 1.080 x 1 600 x 10.00 x 0.50 / 6] x 46 = 6 621 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 28,387 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 22 of 32 ROOM HEATING PEAK LOADS Project Title Date Lot #303 2/16/2006 Room Information Desi n Conditions Room Name Living Area Time of Peak Jan 12 am Floor Area 3,645 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value OT of Btu/hr R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16 .. ar_vi>L1dindQw Solid Wood Door Slab_On_Grade 3,645.0 X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0255 X X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 4,279 2,971.5 0.0566 46.0 7,740 1034.5 0.5000 46.0 23,794 24.0 0.3872 46.0 427 erimeter = 330.0 45.5 15,015 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 51 255 Infiltration:1 1.00 X 1.080 X 3645 X 12.00 X 60] X 46 = 18 101 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 69,356 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 23 of 32 ROOM HEATING PEAK LOADS Project Title Date Lot #303 2/16/2006 Room Information Desicin Conditions Room Name Guest Room / Den Time of Peak Jan 12 am Floor Area 795 Outdoor Dry Bulb Temperature 24 of Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value Z�,T of Btu/hr 795.0 x X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x X 0.0255 x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = _ = = = = = = = = = = 933 1,317.5 0.0566 46.0 3,432 207.5 0.5000 46.0 4,772 perimeter =153.0 45.5 6,962 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 16 099 Infiltration: 11soned .00 X Air Sensible x Area795 x Ceiling Heighhtx ACH.50 / 60] x W 46 = 3 290 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 19,389 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 24 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #303 2/16/2006 Project Title Date Room Name Master Suite Design Indoor Dry Bulb Temperature: 780F Design Outdoor Dry Bulb Temperature: 115oF Design Temperature Difference: 370F Conduction -38 Roof R.38.2x14.16 -21 Wall (W.21.2x6.16) Marvin Windows Area U -Value R DETD 1 X 56.0 X 35.6 X 37.0 X X X X X X Btu/hr 2,287 3,095 6,009 1. Design Equivalent Temperature Difference (DETD) Page Total 11 390 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr FrnchDr (14) (East) Ern.ch3) (East) FrnchDr 3 _ East FrnchDr 4 (East) FrnchDr (5) (South) FxdGlsWdw 61 Abv. (South) FrnchDr 6 (South) FxdGISWdW 62 Abv. South CsmntWdw 1) (West) CsmntWdw (� West ( 0.0 X x X X x x X x x x 15+ + + + + + + + 40.0 x x x X x X x x X X 73 )X x )X x x X ) X 0.323 = = = = = = = = = = 943 ( 0.0 1 40.0 73) 0.323 943 ( 39.5 15+ 0.5 73 0.323 203 ( 39.5 15 0.5 73) 0.323 203 ( 28.0 151+ 0.0 32) 0.323 136 ( 0.0 A 5.9 32) 0.323 61 ( 28.0 1 0.0 32)X 0.323 136 ( 0.0 15 5.9 32)X 0.323 61 ( 0.0 1 12.5 73),x 0.323 295 ( 0.0 15 12.5 73 0.323 295 Sched. Page Total 3 27a Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,600 x 0.500 Watts/sgft x 3.41J Btuh[Watt = 2,730 Occupants 1.00 X 1,600 X 250 Btuh/occ. / 200 sgft/occ. = 2 000 Receptacle 1.00 x 1,600 x 1.500 Watts/sgft x 3.413BtuhlWatt = 8,191 Process 1.00 x 1,600 x 0.000 Watts/sgft x 3.413 BtuhfWaft = 0 Infiltration: C Q0 x1.080 x 1 69.0 x =�(-pOJ x L 0`z01 / 60] � =326 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 33,990 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 600 x 200 Btuh/occ. / 200 sgft/occ. = 1 600 Receptacle 1.00 x 1 600 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process 1.00 x 1 600 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Infiltration: [ 1.00 x 4.8401 x 1 60 x 10.00 x 0.50 / 60] 0.00433 = 2 794 Schedule Air Latent Area Ceiling Height ACH �W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,394 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 25 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #303 2/16/2006 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Master Suite 780F 115°F 37°F Conduction Area U -Value DETD 1 Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr CsmntWdw (3.) _ West Csmn.A1Vdw- West FxdGlsWdw 5 x X x x x x x x X FrnchDr 17 _(West) (West) CsmntWdw (6) (West) CsmntWdw 32 (North) CsmntWdw 33 (North) 73 0.323 94 ( 0.0 1 6.0 ( 0.0 x X x x x x x x x x 15+ + + + + + + + +X + 4.0 x X x x x x x x X 73 )X )X ) X x x x )X )X )X 0.323 = = = = = = = = = = 94 ( 0.0 1 4.0 73 0.323 94 ( 0.0 1 6.0 73 0.323 141 ( 0.0 15 20.0 73) 0.323 471 ( 0.0 15 5.0 73) 0.323 118 ( 0.0 15 8.0 15)X 0.323 39 ( 0.0 15 25.0 15) 0.323 121 ( ( ( Sched. Page Total 1 o7s Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,600 x 0.500 Watts/sqft x 3.413 Btuh/Watt - 2,730 Occupants 1.00 X 1,600 X 250 Btuh/occ. / 200 sgft/occ. = 2,000 Receptacle 1.00 x 1,600 x 1.500 Watts/sgft x 3.413 Btuh/Watt = 8,191 Process 1.00 x 1,600 x 0.000 Watts/sgft x 3.413 BtuhMatt = 00 Infiltration: 1.00 x1.080 x 699 x �1_p 09� x �Q,_50J / 60] E:� Schedule Air Sensible Area Ceiling Height ACH nsT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 33,990 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 600 x 200 Btuh/occ. / 200 sqft/occ. = 1 600 Receptacle 1.00 x 1 600 x 0.000 Watts/sgft x 3.41 Btuh/Watt = o Process 1.00 x 1 600 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Infiltration: 1.00 x 4840 x 1 60 x 10.00 x 0.50 / 60] 0.00433 = 2 794 chedule Air Latent Area Ceiling Height ACH DW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,394 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page:26 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #303 2/16/2006 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction -38 Roof R.38.2x14.16 R-21 Wall (W.21.2x6.16) Marvin Windows Solid Wood Door Area U -Value X DETD1 56.0 35.6 37.0 35.6 Living Area 780F 115°F 37°F Btu/hr 5,210 5,990 19,138 331 1. Design Equivalent Temperature Difference (DETD) Page Total 30 669 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr CsmntWdw 20 (East) 1nchDr (East) CsmntWdw 21 _ East CsmntWdw 22 (East) CsmntWdw (23) (East) CsmntWdw 24 (East) CsmntWdw 25 (East) CsmntWdw 26 (East) FXdGISWdw (38 Abv.) (East) FxdGlsWdw 39 Abv. East ( 0.0 X X x x x x x x X x 1 + + + + + + + + + 15.0 X x x X x X x x X x 73 ) X ) x X x X x x x 0.323 = = = = = = = = _ = 354 ( 0.0 15 24.0 73 0.323 566 ( 0.0 1 15.0 73) 0.323 354 ( 0.0 15,+ 15.0 73)x 0.323 354 ( 0.0 15 20.0 73) 0.323 471 ( 0.0 1 20.0 73)X 0.323 471 ( 0.0 15 15.0 73) 0.323 354 ( 0.0 1 15.0 73) 0.323 354 ( 0.0 15 5.4 73) 0.323 127 ( 0.0 15 5.4 73) 0.323 127 Sched. Page Total 3 530 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 3,645 X 0.500 Watts/sgft x 3.41 Btuh[Watt = 6,220 Occupants 1.00 X 3,645 x 250 Btuh/occ. / 200 sgft/occ. = 4,556 Receptacle 1.00 x 3,645 x 1.500 Wafts/sqft X 3.413 Btuh/Watt = 18,661 Process 1.00 x 3,645 x 0.000 Watts/sqft x 3.41 Btuh[Watt = 0 Infiltration: 1.0o x 1.080 x 645 x�1.2,40l x E:::-7-Qm / 60] E= - Air Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 88,444 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 3645 x 200 Btuh/OCC. / 200 sgft/occ.= 3645 Receptacle 1.00 x 3645 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Process f 1.00 x 3645 x 0.000 Watts/sgft x 3.41 BtuhMatt = 0 Infiltration: I 1.00 x 4.8401 x 364 x 12.00 x 0.50 / 60] 0.00433 = 7 637 --- chedule Air Latent Area Ceiling Height ACH DW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 11,282 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 27 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #303 2/16/2006 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Living Area 78OF 115°F 370E Conduction Area U -Value DETD' Btu/hr 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Solar Gain Orientation Area SGF FxdGlsWdw 40 Abv. East) CsmntW/dmL(27) CsmntWdw 28 (East) East FrnchDr 44 South FxdGlsWdw (59 Abv.) FrnchDr 45 (South) (South) FxdGlsWdw 60 Abv. (South) FxdGlsWdw 37 (South) FxdGlsWdw (42 Abv.) (South) Sld GlsDr 1 South Page Total 1 01 Unshaded Area SGF SC Btu/hr ( 0.0 x x x X x x x X X X 1 + + + + + + + 5.4 x X X x X X x x X x 73)X x X x x X )x 0.323 = = = = = = = = __ = 127 ( 0.0 15+ 20.0 73) 0.323 471 ( 0.0 1 20.0 73) 0.323 471 ( 28.0 15+ 0.0 32) 0.323 136 ( 0.0 1 5.9 32) 0.323 61 ( 28.0 1 0.0 32)X 0.323 136 ( 0.0 1 Ir 5.9 32)x 0.323 61 ( 48.0 15 0.0 32) 0.323 232 ( 0.0 151+ 5.4 32)x 0.323 56 ( 48.0 1 0.0 32 0.323 232 Sched. Page Total 1 984 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 3,645 X 0.500 Watts/sqft x 3.413 Btuh/Waft - 6,220 Occupants 1.00 X 3,645 X 250 Btuh/occ. / 200 sgft/occ. = 4,556 Receptacle 1.00 x 3,645 x 1.500 Watts/sqft x 3.413 Btuh/Watt = 18,661 Process 1.00 x 3,645 x�� 0.000 Watts/sgft x 3.413 Bt��uh/Watt = 0 Infiltration: QO x x E:]--] x QO x �Q.;iQJ / 60] =37J = Schedule Air Sensible Area Ceiling Height ACH nsT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 88,444 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 3645 x 200 Btuh/occ. / 200 sgft/occ. = 3645 Receptacle 1.00 x 3645 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process 1.00 x 3645 X 0.000 Watts/sqft x 3.413 Btuh[Watt = 0 Infiltration: [ 1.00 x 4840 x 364 x Heigh x 60] 0.00433 = 7 637 Schedule Air Latent Area Ceiling Height ACH DW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 11.282 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 28 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #303 2/16/2006 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Living Area 780F 115°F 370E Conduction Area U -Value DETD' Btu/hr X = X = X = X = X = X = X = X = X = 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxdGlsWdw (43 Abv.) South ExdGISlNdw (41 Ah FrnchDr 27 (South) SIdgGIsDr 48 _(South) (West) FxdGlsWdw (44 Abv.) (West) FxdGlsWdw 45 Abv. (West) FxdGlsWdw 46 Abv. (West) FxdGlsWdw 34 (West) FxdGISWdW 35 Abv.) (West) SIdgGIsDr 41 West ( 0.0 x x X X x x x1 x x 1 + + + + + + + + + +F 5.4 x x x x X X X x X 32 ) X ) x X x x x 0.323 = = = = = = = = = 56 ( 0.0 1 5.4 32 0.323 56 ( 0.0 1 40.0 32) 0.323 413 ( 165.9 1 2.1 73) 0.323 853 ( 0.0 1 5.4 73) 0.323 127 ( 0.0 15 5.4 73)X 0.323 127 ( 0.0 5.4 73)X 0.323 127 ( 0.0 11' 44.0 73)X 0.323 1,037 ( 0.0X 1 9.2X 7)x 0.323= 217 ( 0.0 15 48.0 I 73) 1 0.323 1 1,131 Sched. Page Total a 144 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 3,645 X 0.500 Watts/sqft x 3.413 BtuhfWatt - 6,220 Occupants 1.00 X 3,645 X 250 Btuh/occ. I 200 sgft/occ. = 4,556 Receptacle 1.00 x 3,645 x 1.500 Watts/sgft x 3.413 Btuh[Watt = 18,661 Process 1.00 x 3,645 X 0.000 Watts/sgft x 3.413 Btuh[Watt = 0 Infiltration: = 09 x 1.080 x 545 x 12 Q x [L�--o- / 60] 0 = � Schedule Air Sensible Area Ceiling Height ACH nT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 88,444 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 3645 x 200 Btuh/occ. / 200 sgft/occ. = 3645 Receptacle 1.00 x 3645 x 0.000 Wafts/sqft x 3.41 Btuh/Watt = 0 Process 1.00 x 3645 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = 0 Infiltration: 1.00 x 4840 Air Latent Area Ceiling Heighx 3645 x Height x ACH 60] 0.00433 = 7 637 chedule QW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 11,282 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 29 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #303 2/16/2006 Project Title Date .►x-11 l • ul Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Living Area 780F 115°F 37°F Btu/hr 0 Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxdGlsWdw 55 Abv. x x x x x x x x x xL Sldg.GlsDL(4Q) FxdGlsWdw 54 Abv. _(West) (West) West FxdGlsWdw 34 West FxdGlsWdw (36 Abv.) (West) CsmntWdw 16 (West) FrnchDr 43 (North) FxdGlsWdw 58 Abv. (North) FxdGlsWdw 47 Abv.) (North) FXdGISWdW 34 North ( 0.0 x x x x x x x x x xL 1 + + + + + + + + 10.0 x x X X X X X x X x 73 )X )X x X x ) x X 0.323 = = = = = = = = __ = 236 ( 0.0 15+ 48.0 73)x 0.323 1,131 ( 0.0 15 10.0 73 0.323 236 ( 0.0 15 44.0 73)x 0.323 1,037 ( 0.0 1 9.2 73) 0.323 217 ( 0.0 15 12.5 73)X 0.323 295 ( 0.0 1 40.0 15) 0.323 194 ( 0.0 1 10.0 15) 0.323 48 ( 0.0 15 5.4 1 0.323 26 ( 0.0 16,+ 1 40.0 I 15) 0.323 194 Sched. Page Total 3 613 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 X 3,645 X 0.500 Watts/sgft x 3.413 Btuh[Watt = 6,220 Occupants 1.00 X 3,645 X 250 Btuh/occ. /A3.41 sgft/occ. = 4,556 Receptacle 1.00 x 3,645 x 1.500 Watts/sqft x Btuh/Waft = 18,661 Process-1.000xx 3,645 x 0.000 Wafts/sgft xBtuh/Watt = 0 Infiltration: 00 x 1=o-881 x 3,645 x =.2,_QOJ x 59 / 60] Schedule Air Sensible Area Ceiling Height ACH 4nJ Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 88,444 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 3 645 x 200 Btuh/occ. / 200 sgft/occ. = 3645 Receptacle 1.00 X 3 645 x 0.000 Watts/sqft X 3.41 Btuh[Watt = O Process 1.00 7c 3 645 X 0.000 Watts/sqft x 3.413 BtuhlWaft = 0 Infiltration:[ 1.00 x 4840 x 364 x 12.00 x 0.50 / 60] 0.00433 = 7 637 Schedule Air Latent Area Ceiling Height ACH OW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 11,282 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 30 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #303 2/16/2006 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X DETD1 Living Area 780E 115°F 37°F Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxdGlsWdw 57 Abv. (North) ExdGls_-Wdyv_(4B-Ab_v_) North FrnchDr 42 (North) FxdGlsWdw 56 Abv. (North) FxdGlsWdw (49 Abv.) (North) CsmntWdw 13 (North) CsmntWdw 14 (North) CsmntWdw 15 (North) 26 ( 0.0 1d+ 40.0 ( 0.0 x X x x x x x x x x 1 + + + + + + + + 10.0 x x x x x X x x x x 15 )X ) X x x )X )x 0.323 = = = = = = = = = = 48 ( 0.0 151+ 5.4 15 0.323 26 ( 0.0 1d+ 40.0 15) 0.323 194 ( 0.0 1 10.0 15)x 0.323 48 ( 0.0 1 5.4 15)x 0.323 26 ( 0.0 1 15.0 15)X 0.323 73 ( 0.0 1 15.0 15) 0.323 73 ( 0.0 15 4.0 15)x 0.323 19 ( ( Sched. Page Total sol Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 3,645 x 0.500 Watts/sqft x 3.413 Btuh/Watt = 6,220 Occupants 1.00 X 3.64 X 250 Btuh/OCC. / 200 sqft/occ. = 4,556 Receptacle 1.00 x 3,64 x 1.500 Watts/sgft x 3.413 BtuhlWatt = 18,661 Process 1.00 x 3,645 x 0.000 Watts�/sgfttx 3.413 Btuh[Watt = 0 Infiltration: 1_.p0 x 1.oso x � x 2.00 1 x �0 X01 / 60] Schedule Air Sensible Area Ceiling Height ACH nT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 88,444 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 3 645 x 200 Btuh/ocC. / 200 sgft/occ. = 3645 Receptacle 1.00 x 3645 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Process 1.00 x 3645 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: [ 1.00 x 4840 x 364 x 12.00 x 0.50 / 60] 0.00433 = 7 637 Schedule Air Latent Area Ceiling Height ACH DW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 11.282 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 31 of 32 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #303 2/16/2006 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Guest Room / Den 780F 115°F 37°F Conduction Area U -Value DETD' Btu/hr X 56.0 = 1,136 X 35.6 = 2,656 X 37.0 = 3,839 X - X = X = X = X = X = 1. Design Equivalent Temperature Difference (DETD) Page Total 7 631 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr CsmntWdw (10) -(East) ErnchD (East) CsmntWdw 18 (South) FrnchDr 21 _ South FxdGlsWdw (59 Abv.) (South) FrnchDr 19 (West) CsmntWdw 7 West CsmntWdw 8 (West) CsmntWdw 11) (North) CsmntWdw 12 North ( 0.0 X x X x x x x x x x 1 + 15 + 15 + 15 + 1 + 15 + 15 + '15+ 1 + 151+F 12.5 x x x x x x x x X x 73 ) X )x ) X x x X X ) X ) x 0.323 = = = = = = = = __ = 295 ( 0.0 21.4 73 0.323 504 ( 0.0 13.3 32 0.323 137 ( 0.0 48.0 32) 0.323 496 ( 0.0 10.0 32) 0.323 103 ( 0.0 21.4 73) 0.323 504 ( 0.0 37.5 73)X 0.323 884 ( 0.0 13.4 73) 0.323 316 ( 0.0 15.0 1 0.323 73 ( 0.0 15.0 15 0.323 73 Sched. Page Total 3 385 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 795 X 0.500 Watts/sgft x 3.41 Btuh/Watt - 1,357 Occupants 1.00 x 795 x 250 Btuh/occ. / 200 sgft/occ. = 994 Receptacle 1.00 x 795 x 1.500 Watts/sgft x 3.413 Btuh/Watt = 4,070 Process 1.00 x 795 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: E 1.00 x1.080 x EL�--u- x l�0 oo x .59 / 60] _ Schedule Air Sensible Area Ceiling Height ACH :IT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,082 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 795 x 200 Btuh/occ. / 200 sgft/occ. = 795 Receptacle 1.00 x 795 x 0.000 Watts/sgft X 3.413 BtuhMatt = 0 Process 1.00 x 795 x 0.000 Watts/sqft x 3.413 Btuh/Waft = 0 Infiltration: 1.00 x 4840 x 795 x 10.00 x 0.50 / 60] 1 0.00433 = 1 388 chedule Air Latent Area Ceiling Height ACH �W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2.183 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 32 of 32 R F STRUCTURAL CONSULTANTS, INC. ------------------------------------------------------------------------ ------------------------------------------------------------------------ 75-153 MERLE DRIVE, STE. B, PALM DESERT, CA 92211 PHONE (760) 836-1000 FAX (760) 836-0856 E- MAIL RAYMOND@RFSTRUCTURAL.COM OCTOBER 5, 2006 CAM BARNES C/O PAUL GOLDEN 32 EUCALYPTUS BELVEDERE, CA. 94920 Re.: THE BARNS RESIDENCE THE HIDEAWAY, LOT # 303 53264 VIA PISA LA QUINTA, CA. FOLLOW-UP TO WALK THROUGH JOB NO.: 4333 DEAR CAM THIS LETTER ADVISES THAT WE HAVE OBSERVED THE STRUCTURAL REQUIREMENTS THAT ARE VISIBLE DURING CONSTRUCTION AT THE TIME OF OUR SITE VISIT. WE BELIEVE THAT THE AS -BUILT CONSTRUCTION AT THE TIME OF OUR VISIT IS IN GENERAL CONFORMANCE WITH OUR STRUCTURAL PLANS AND RELEVANT CORRESPONDENCE ISSUED BY OUR OFFICE. WE OBSERVED THE BUILDING IN ITS FRAMED CONDITION PRIOR TO INSTALLATION OF DRYWALL AND STUCCO. WE OBSERVED THE VISUAL AND ACCESSIBLE STRUCTURAL REQUIREMENTS. (EXCLUSIONS ARE ITEMS SUCH AS: FOOTING SIZE AND REINFORCEMENT, TOP PLATE SPLICES, ROOF SHEATHING, AND ANY STRAPS ABOVE THE ROOF SHEATHING.). RESPECTFULLY SUBMITTED 6 QROFESS/p N Q�'�yp,0 M F,gp�F2c `c No-57958rn * Exp. 06-30-0 ZEYAD FAQIR PE v;,gTF CIVIL o���Q . OF CALIF ✓ 1,,�< P.O. Boa 12980 Paint DescMCA 92255 (760) 346-8015 (760)346-2548 Fax wwwSciro.nct FEIR® ENGINEERING, inc. March 28, 2006 City of La Quinta 78-495 Calle Tampico La Quinta, CA 92253 Re: Lot 303, Tract 29894-2 53264 Via Pisa. Barnes Residence This lefter_will serve to state that we field checked the pad elevation for the.above project and found R to be: 1016.0 .(Plan) 1016.0 (High) 1015.9 (Low) If you have any questions, please call me at (760) 346-801-5. Sincerely, James D. Feiro Vice President RCE 24176 JDF/dpo cc: Golden Construction, Inc. pFESSIO�� D. i M r o. C-24176 2 EXP. 12/31/07c CIVIL Q�`Q lF OF CA AUG 1 Sladden Engineering 9 2005 6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 -------------------- 39-725 Garand Ln., Suite G, Palm Desert, CA 92211 (760) 772-3893 Fax (760) 772-3895 August 3, 2005 Golden Construction 73-710 Fred Wring Drive Palm Desert, California 92211 Attention: Mr. Paul Golden Project: Lot 303 — Via Pisa The Hideaway La Quinta, California Subject: Geotechnical Update Project No. 544-5595 05-08-762 Ref: Report of Observations and Testing During Fine Grading prepared by Sladden Engineering dated August 13, 2003, Project No. 544-2199, Report No. 03-04-225. Geotechnical Update prepared by Sladden Engineering dated February 25, 2003, Project No: 544-2199, Report No. 03-02-106. Geotechnical Engineering Report prepared by Earth Systems Consultants dated September 22, 2000; File No. 07117-10, Report No. 00-09-772. Report of Testing and Observation During Rough' Grading prepared by Earth Systems Southwest dated August 28, 2002, File No. 07117-11, Report No. 01-07-718. As requested, we have reviewed the above referenced geotechnical reports as they relate to the design and construction of the proposed single family residence. The project site is identified as Lot 303 along Via Pisa within phase 113 of the Hideaway Golf Club development in the City of La Quinta, California. It is our understanding that the proposed residence will be a relatively lightweight wood frame structure supported by conventional shallow spread footings and concrete slabs on grade. The lot was previously graded during the rough grading of the Hideaway project site and was recently regraded. The rough grading included overexcavation of the native surface soils along with the placement of engineered fill material to construct the building pads. The recent regrading included processing the surface soils along with minor cuts and fills to construct the individual building pads. Some additional overexcavation :was performed in areas where the building envelopes were reconfigured. The, initial site grading is summarized in the referenced Report of Observations and .Testing During Rough Grading, prepared by Earth Systems Southwest and the recent grading is summarized in the referenced Report of Observations and Testing During Fine Grading prepared by our firm. August 3, 2005 -2- Project No. 544=5595 05-08-762 The referenced reports include recommendations pertaining to the construction of residential structure foundations. Based upon our review of the referenced reports, it is our opinion that the structural values included in the referenced grading report remain applicable for the design and construction of the proposed residential structure foundations. Because the lot has been previously graded, the remedial grading required at this time should be minimal. The building area should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted so that a minimum of 90 percent relative compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. Allowable Bearing Pressures: The allowable bearing pressures recommended in the grading report prepared by Sladden Engineering remain applicable. Conventional shallow spread footings should be bottomed into property compacted fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 2000 psf, respectively. An .allowable increase of 300 psf for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be utilized if desired. The maximum allowable bearing pressure should be 3000 psf. The recommended allowable bearing pressures maybe increased by one-third for wind' and seismic loading. The bearing soils are non -expansive and fall within the "very low" expansion category in accordance with Uniform Building Code (UBC) classification criteria. Pertinent 1997 UBC Seismic Design parameters are summarized on the attached data sheet. If you have questions regarding this letter or the referenced. reports, please contact the undersigned. Respectfully submitted, SLADDEN ENGIN R G hAC FN "aAc ERSO �Op Brett L. Anderson Principal Engineer cy GAS\ `�O SER/pc STATE OF GP\! Copies: 4/Golden Construction Sladden Engineering August 3, 2005 -3- Project No. 544-5595 05-08-762 1997 UNIFORM BUILDING CODE INFORMATION The International Conference of Building Officials 1997 Uniform Building Code contains substantial revisions and additions to the earthquake engineering section in Chapter 16. Concepts contained in the code that will be relevant to construction of the proposed structure are summarized below. . Ground shaking is expected to be the primary hazard most likely to affect the site, based upon proximity to significant faults capable of generating' large earthquakes. Major fault zones considered to be most likely to create strong ground shaking at the site are listed below. Fault Zone Approximate Distance From Site Fault Type (1997 UBC) San Andreas 9.8 km A [San Jacinto 26 km A Based. on our field observations and understanding of local geologic conditions,. the soil profile type judged applicable to this site is So, generally described as stiff or dense soil. The site is located within UBC Seismic Zone 4. The following table presents additional coefficients and factors relevant to seismic mitigation for new construction upon adoption of the 1997 code. Sladden Engineering Near -Source Near -Source Seismic Seismic Seismic Acceleration . Velocity' Coefficient Coefficient Source Factor, Na Factor, Nv C. Cv San Andreas 1.01 1.22 0.44 Na 0.64 Nv San Jacinto 1.0 1.0 0.44 Na 0.64 N� Sladden Engineering R F STRUCTURAL CONSULTANTS, INC. --------------------------------------------------------------------------------------- --------------------------------------------------------------------------------------- 75-153 MERLE DRIVE, STE. B, PALM DESERT, CA 92211 PHONE (760) 836-1000 FAX (760) 836-0856 K E- MAIL RAYMOND@RFSTRUCTURAL.COM July 2, 2006 CITY OF LA QUINTA, DEPARTMENT OF BUILDING AND SAFETY LA QUINTA, CA. Re.: THE BARNES RESIDENCE THE HIDEAWAY LOT # 303 53-264 VIA PISA LA QUINTA, CA JOB NO.: 4333 TO WHOM IT MAY CONCERN I HAVE BEEN SUPPLIED WITH TRUSS CALCULATIONS PREPARED BY STRUCTURAL COMPONENTS, INC., PALM DESERT, CALIFORNIA, DATED JUNE 22, 2006, JOB NO 4114-5Y, FOR THE PROJECT NOTED ABOVE. UPON REVIEW OF THE TRUSS CALCULATION PACKAGE, AND IN LIGHT OF THE STRUCTURAL DESIGN DOCUMENTS, I FIND THE TRUSS LAY -OUT AND LOADING IN GENERAL CONFORMANCE WITH THE STRUCTURAL DESIGN INTENT AS DOCUMENTED IN THE STRUCTURAL CALCULATIONS PREPARED BY OUR FIRM FOR THE NOTED PROJECT. IF YOU HAVE ANY QUESTIONS OR COMMENTS REGARDING THESE ISSUES OR ANY OTHER ISSUE PLEASE DO NOT HESITATE IN CONTACTING US. ZEYAD FAQIR P.E. QROFESS/o, y m No -57958 T Exp. 06-30-0 CIVIL �Q �FCF CAL1F���/ ,> Sep 21 05 03:17p �y Bahr Electric Bahr Electric 74-991 Joni Dr. #5 Palm Desert, Ca 92260 760 341-5614 fax 760 773-2627 760 7732627 U� 1 2 l205 ae8BY6..s.e.......��. LOAD CALCS FOR L_O+ SoS BARNES RESIDENCE HIDE -A -WAY COUNTRY CLUB * 1ST A/C 7.2 2"D A/C 5.7 3RD AIC 5.7 4TH '►/C 3.4 5"H A/C 2.9 (GARAGE A/C) 1 OVEN 5.0 KVA 1 COOKTOP (GAS) .8KVA 1 DISHWASHER 1.5KVA 1. DISPOSAL .8KVA 2 APPLIANCE CIRCUITS 3.OKVA 1 WASHER 2.2KVA 1 DRYER 5.OKVA 1 LAUNDRY 1.5KVA 1 LANDSCAPE 2.OKVA 1 POOLJJACUZZI 8.0KVA 6,880 SQUARE FEET AT 3VA PER FOOT 20,6KVA TOTAL 50.4KVA I"' r A/C AT 125% 10.8 2ND —5 T11 A/C @ 100% 17.7 15T 10 KVA @ 100% 10.0 REMAINDER C: 40% 16.2 5 FAU 4.0 TOTAL 58.7KVA 58.7KVA DIVIDED BY 230VOLTS (58700 DIVIDED BY 230) IS EQUAL TO 255.2 RECOMMEND USE OF 400 AMP SERVICE RECOMMEND USE OF 400 AMP SERVICE ./'FROM : GOLDEN CONSTRUCTION COMPANY PHONE NO. 760 776 4315 Sep. 21 2005 03:00PM P1 Sep 2105 03%17r Behr Electric 760 7732627 p.1 f nnri j Bahr Electric, 14-991 Joni Dr. #5 Palm ,Desert, Ca 92260 760 341-5614 fax 760 773-2627 LOAD CALLS FOR i-.ot -2,aS BARNES RESIDENCE HIDE-A.-WAY COUNTRY CLUB 15T'A/C 7.2 2ND A/C 5.7 3RD A/C 5.7 4TH ,A/C 3.4 5TH AIC 2.9 (CTARAGE A/C) 1 OVEN 5.0 K\7A 1 COOKTOP (GAS) .8KVA 1 DISHWASHER 1.5KVA 1 DISPOSAL .8KVA 2 APPLIANCE CIRCUITS 3.OKVA 1 WASHER 2.2KVA 1 DRYER 5.OKVA 1 LAUNDRY 1.5KVA 1 LANDSCAPE 2AKVA 1 POOL/JACUZZI 8.OKVA 6,880 SQUARE FEET AT 3VA PER FOOT 20.6KVA TOTAL 50.4KVA 1"' A/C AT 125%. 10.8 2ND _,5T11 A/C C 1.00% 17.7 1$. 10 KVA g 100% 10.0 RFMAINDER a. 40% 16.2 5 FAU 4.0 TOTAL 58.7KVA 58.7KVA D[VrDED BY 230VOLTS (58700 DIVIDED BY 230) IS EQUAL TO 255.2 RECOMMEND USE OF 400 AMP SERVICE