0310-293 (SFD)i
LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class- Exp. Date
,51Si]3 13HIC 3 10r)1?12(
l/
/Date ' %J� Signature of Contractor!-��� f Ake
r / �.a
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code),
( ) I, as owner of the property, am.exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
( ) I am exempt under Section B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier 13I'AS'.F.FUN I) Policy No. 224.4095-2009
(This. section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation provisions of Section 3700 of the Labor
Code., I`shall forthwith comply with•those provisions.I `/
Date %/ ff Applicant � l9.lr':, i A � ;/
Warning: Failure to secure*Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to�the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby'authorize representatives of this City to enter upon
the above-mentioned property/for inspection pugposes.\ `
i'. / /
Signature (Owner/Agent)rfr��f*'/{''/Li�?i/ ate
2P4%
BUILDING PERMIT PERMIT# f.
0.11 10-2!A-3
DATE VALUATION b 5(nt 90 LOT 27 4 TRACT 29894-2
JOB SITE
ADDRESS F3-J�'P.-% VIAS.A.
APN 711.5.,52(1-020
OWNER
CONTRACTOR/DESIGNER/EN (NEER
J�! 1c2:Ct r 1), 1ORM
fi M. P.M..W J01*THS l;%1':.aUCRIT & CONKRUC i7ra
49641. AVRADER
POST (3F�'.(Vk1:D12A)M1':' 4656
t.Q222x:1
l
�ALast���A CA 92,61-4C
(760)346.3366 CMI'11 2096
USE OF PERMIT
13555 Sr SF„'J•' DT ryVPt ". IT DOPS MCT INCLUDE POOUaP.A OR ,
BLOCK WA L . 206 h -C,
CUSTOM COMSTRUCTIUN 51555.00 OF
POR.Ci-11111 l.TIC, 1,980.00 NF''
0ARA!:GMARPt3RT 11519.04 SP
FST. i9 :.rED OOSM OF {:t?AI M1.JC: IO.P3
724,5W.90
PERAIM FEE N'UA014AaCV
CONSTRUCTION FEE 101.000.418.000 $21114.50
PLAN CHECK FEZ 101-•000,439-318 $2,i89.95
FEE DEPOOIT 1.01-000.439»318. -$1,250"011
M-ECHARriC:AL. PEE 101-000-421-000 $232.00
ELG* IACCAL FBE 101.000.420.000 $06.31
PLt)MBIAf0 P W 101-000-419-000 $707.50
VRONO i4it5TWX FIM, - Rrt.%. D 1,01.000.241.0360 $72,45
ORAJENNi'O FEE 101-000-4,23-0100 $15:00
OL'VELOPM IMPACT 1ERF $2,485,00
PFiECISK P .A14 101-000.441445 $'-100.00
ART IN PUBLIC 'PLACES - RESM 210.000-445»000 52,31,us
:NI349rAL C'0]3"J'.11.M(MI N AND PLAW CHECK
_. TZ 551 PRE -PAID 1,M
l3IJX NOW
-$1,250,1)(3
LFEBXMI,1:7R.Ui.:S•YLTS
2 6 2004
CITY OF IA O111NTA
FINANCE DEPT.
RECEIPT
DATE
BY--
DATE FINALE/DD
INSPECTqFy
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING APPROVALS
MECHANICAL APPROVALS
Set Backs
Underground Ducts
Forms & Footings
Ducts
_ Slab Grade
Return Air
Steel
Combustion Air.
Roof Deck
Exhaust Fans
O.K. to Wrap
F.A.U.
Framing
Compressor
Insulation
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath
Final
Final
BLOCKWALL APPROVALS
POOLS - SPAS
Steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final I I
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
Gas Test
Appliances
Final
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Final
Utility Notice (Perm)
COMMENTS:
°
i i
LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9'(commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and -effect.
License # Lic. Class Exp. Date
5187113 L3HI
Date Signature of Contractor
OWNER -BUILDER DECLARATION
3 0131.l2C
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code). .
( ) I am exempt under Section B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier STATE FUND Policy No. 72-;-4905-2004
(This. section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation provisions of Section 3700 of the Labor
Code, I shall forthwith comply with those provisions.
Date: Applicant
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon
the above-mentioned property for inspection purposes.
Signature (Owner/Agent) Date
BUILDING PERMIT' PERMIT#
03110.4293
DATE VALUATION LOT TRACT
0212�I17AC 274 ^ 298N_2
JOB SITE NO N
ADDRESS &3-33 TM VISSA
OWNER
CONTRACTOR /DESIGNER/E
.LSF; Y %3 HORN►I3
I 1� :6�I '1 i -a ['vC xffm:tIrnga'
49641 AVI A TSR
POST EiPY CE DTs'.AWh-X 4,65,15
I QIUMA. CA 92253
W -IM T ESZM- `i' CA 9220-0
(76P)346r3366 C 14 2196
USE OF PERMIT
,Tc"1T..F' PANTY, IY wa-UNG
$Sig SF SI''O-LOT 27NPERHd IT DOES ]:41. 9' INCLUng POtJi.JSPA OR
BLOCK X1 &L1,8, 2001 CSC.
Ci=°ATOM CONSTRUCTIf 81593.00 sig
PORCH/P,A1110 1,490100 SF
FS'I:iMATED COST OF L"O S7['Rtl'MIi; N
724,500SO
`ice E^cIt/ r YiMR 611M ANRY
crr3klrT1tUC'1'ION FIE9 101.000.418.000 $2,714,50
VI A14 CHECK ",I, .101-000-439-318
FFM DEPOSIT 101.000.439.318 -$1,250.90
MECHANICAL; .FEE 101.0013-421-000 $252.00
ELECTIUCAL 'p EE 101-000-420-000 2436,=11
'PLtiMEf1`Ro ME 101-000-419-000 $3.0.50
STRCM .t OTION, FEE -11111D 101.000.241.0100 M0
ORLADINQ PE -E 101-000-423-000 $15.00
DEVELOPER IMPACT FFF 'SZ405,00
PPF t"n! P*LAN 101-000.441-345 $180.00
ART IN PUBLIC PLACU - RESIL 270-000.445.000 $1,3t 1.25
e7ti.lA-s-WfAt.r COYoJ.RtlCTICNIT A3T. D PUN Cl:,.t`J.. K
$9,604.4f
LESS RUE -PAID FEW
<$1,250.00
` (YJCA1 PJ!M s Xr 1+'1yEN DUE HOW
95! 4A6
RECEIPT
DATE
BY
DAT FINALED
INSPECTOR
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
I INSPECTOR
BUILDING APPROVALS
Set Backs
MECHANICAL APPROVALS
Underground Ducts
_ _ _
Forms & Footings (
Ducts
Slab Grade
Return Air
_ _
Steel
Combustion Air
_
Roof Deck
Exhaust Fans
O.K. to Wrap XA y
F.A.U.
Framing
Compressor
Insulation
Vents
Fireplace P.L. W77_
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath —
Drywall - Int. Lath - S
Final
Final
BLOCKWALL APPROVALS
POOLS - SPAS
Steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
Gas Piping
PLUMBING PPROVALS
Gas Test
Electric Final
Waste Lines
Heater Final
_
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
Gas Test
Appliances
Final
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring I
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power S
Final
Utility Notice (Perm)
COMMENTS: .p C -
��� �� \ ,- `�,�,C� • ���Q �,...._�,`
1YYYl vV 11/ln���
4 L 7
`A _
/� s
l� � �y`��"L C
r Pleisel i1�2i�y�L7%lss
5 - 311 VIA Ti •
Buildingf J rf
Address f f
Mailing
Address
J
4 4 QuAto
P.O. BOX 1504
78-495 CALLE TAMPICO
QUINTA, CALIFORNIA 92253
City( Zip ( State I
Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that 1 am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and
effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5.Susiness and Professions Code: Any city or county which requires a
permit to construct, atter. Improve, demolish, or repair any structure, prior to its Issuance also
requires the applicant for such permit to rile a signed statement that he Is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division3 of the Business and Professions Code. or that. he is exempt therefrom, and the basis
for file alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit
subjects the applicant to a civil penalty of nor more than five hundred dollars ($500).
l; I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Suisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of Completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
I'1 1, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or Improves thereon, and who contracts for
such projects with a confractoris) licensed pursuant to the Contractor's License Law.)
i? 1 am exempt under Set. B. 8 P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
rl Copy is filed with the city. O Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS'COMPENSATIONINSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of th? work. for which this permit is issued, I shall not
employ any person in any manner so as t0 become subject to the Workers' Compensation
Laws of California.
Date Owner
NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
Ihereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives -of this city to enter the above.
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
3
03
APPLICATION ONLY
WING: TYPE'C`OON`'STT.'5,r
_/ � OCC. /GRP.
Number 1—x l/ ?, U �� V
al Description i l (7 , ? 'rl� l _I � `? f '
CMA i , �... " IZlp� TAA ITeI.J l:%OR
Description
Sq. Ft.� No.
Size �- Sto
No. DIN.
New Add ❑ Alter ❑ Repair ❑ Demolition ❑
Zip�j ^ '� =
Tel
State Lic
City
& Classif
Plan Chk. Dep.
Lic. #
Arch., Engr.,
.,__Designer/`�_
Const.
Mech.
Address
Electrical
Tel.
4 4 QuAto
P.O. BOX 1504
78-495 CALLE TAMPICO
QUINTA, CALIFORNIA 92253
City( Zip ( State I
Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that 1 am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and
effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5.Susiness and Professions Code: Any city or county which requires a
permit to construct, atter. Improve, demolish, or repair any structure, prior to its Issuance also
requires the applicant for such permit to rile a signed statement that he Is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division3 of the Business and Professions Code. or that. he is exempt therefrom, and the basis
for file alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit
subjects the applicant to a civil penalty of nor more than five hundred dollars ($500).
l; I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Suisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of Completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
I'1 1, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or Improves thereon, and who contracts for
such projects with a confractoris) licensed pursuant to the Contractor's License Law.)
i? 1 am exempt under Set. B. 8 P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
rl Copy is filed with the city. O Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS'COMPENSATIONINSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of th? work. for which this permit is issued, I shall not
employ any person in any manner so as t0 become subject to the Workers' Compensation
Laws of California.
Date Owner
NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
Ihereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives -of this city to enter the above.
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
3
03
APPLICATION ONLY
WING: TYPE'C`OON`'STT.'5,r
_/ � OCC. /GRP.
Number 1—x l/ ?, U �� V
al Description i l (7 , ? 'rl� l _I � `? f '
CMA i , �... " IZlp� TAA ITeI.J l:%OR
Description
Sq. Ft.� No.
Size �- Sto
No. DIN.
New Add ❑ Alter ❑ Repair ❑ Demolition ❑
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
FINAL DA
Issued by:
Validated
Validation
Side Setback from Property Line
WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION
Estimated Valuation
PERMIT
AMOUNT
.n: 7
Plan Chk. Dep.
Plan Chk. Bal.
-77 f
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
TOTAL
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
FINAL DA
Issued by:
Validated
Validation
Side Setback from Property Line
WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION
Coacjhella.,Valley Unified scnool vislriclt
P.O. Box"147, Thermal, CA 92274
;760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMM/IND. AMOUNT:
DATE:
RECEEPT:
CHECK H:
MITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: Hideway Date: February 26, 2004
Owner's Name: Jerry D Horn Phone No.
Project Address: 53-317 Via Pisa La Quinta, CA 92253
Project Description: 1 SFD
APN: 775-520-020 Tract #: 29894-2 Lot #'s: 274
Type of Development: Residential X3= Commercial
Total Square Feet of Building Area: 8,555 sq. ft.
Industrial
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement
under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer.
Dated: 0 Signatur
r,r**r•,w«,r*,w*«.,►*+rt*,r***i*********•*****•wrw**.*r,►,t**«*rr,►ww,rrw*rw,rr***
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Project
17620 65995 Approval
Number of Sq -Ft- 8,555
Amount per Sq.Ft. _ $ 2.19
Amount Collected $ 18, 735.45
Building Permit Application Completed: Yes/No
By: Carey M. Carlson
Asst. Supt., Business Serv.
Agreement Existing Not Subject to Fee
Prior to 1/1/87 Requirement
Note:
Certificate issued by: El V i ra, Mattson Signature:
Office Technician
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to
the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of
these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall
serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of
any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether
payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This
Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School
District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project
that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance.
MV:c/mydocs/devfees/certificate of compliance 09/30/02
WHEN RECORDED hAIL TO:
Rnrn , .T,-rry
19 Heather Hill Ln
SHeridan, Wy 82801-9046
MAIL TAX STATEMENT TO:
Same as above
A
®®C = 2003-041070
01/17/2003 08:00A Fee:19.00
Page 1 of 5 Doc T Tax Paid
Recorded in Official Records
County of Riverside
Gary L. Orso
Assessor, County Clerk 8 Recorder
11111111111111111111111111111 N 1111111111111111111
M
$
U
PAGE
SLE
DA
PCOV
NOCOR
SMF
"Sc.
*
R
L
COPY
IONG
REFUND
NCHG
EXAM
DOCUMENT TRANSFER TAX $-'4?.
X Computed on the consideration or value of property conveyed; OR
Computed on the consideration or value less liens or encumbrances YS_`
remaining at the time of sale.
l5 , c q O • o a O . � Signature of Declarant or Agent determining tax - Firm Name
TQ -ft -. o 9-0 0 5 -LP
GRANT DEED
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND
LA QUINTA PARTNERS, LLC, a Delaware limited liability company ("Grantor"), hereby
GRANT(S) to ,Terry D Horn a Mar ri Pd Man ag ** ("Grantee"), the real property
located in the City of La Quinta, County of Riverside, State of California, described as:
** His Sole and Seperate Property
See Legal Description attached hereto and incorporated herein as Exhibit "A".
SUBJECT TO all matters of record including, without limitation, the covenants and
agreements described in Exhibit "A" attached. hereto.
Dated: 12-27-02
1-LA/627969.1 1
ND LA QUINTA PARTNERS, LLC,
a Delaware limited liability company
By: Nationwide Realty Investors, Ltd.,
an Ohio limited liability company
its managing member
%
By: �x,./,
President and
Chief Operating Officer
STATE OF
• ) ss.
' COUNTY OF 1 Vern, i d
Ong' (ID 2002, before me, the and s fined, a notary public in and
for. said State, personally app ared J S Vi L . Arenszr ,, ,v personally known to me (or
proved to me on the basis of satisfactory evidence) to be the person(s) whose name(`s,) is/kge
subscribed to the within instrument and acknowledged to me that he/s'he/they executed the same
in his/hWth'bk authorized capacity(ies), and that by his/hbr/ftr signatureN on the instrument
the person(3.), or the entity upon behalf of which the personN acted, executed the instrument.
WITNESS MY HAND AND OFFICIAL SEAL.
Signature -,,Mm Aa ., [SEAL]
KATHRYN L. HUNTER
Commission # 1382692
Z , .m Notary Public - California
Riverside County
MY Comm. Expires Nov 1, 2006
111111 till lilt, lilf till IIIM III nill it, w, 2003-041070
1-1,,•1/627969.1 2
Parcel No. 1:
EXHIBIT "A"
Legal Description.
Lot 274 (the "Lot") of Amended Tract No. 2 9 8 9 4_ 2 as shown on a
Subdivision Map (the "Map") recorded on _DECEMBER 12, 2002 , in Book 327 ,Pages 56
to 88 , inclusive, of'Maps, in the Office of the Riverside County Recorder.
EXCEPTING AND RESERVING THEREFROM TO GRANTOR, and its successors,
assigns, invitees, licensees and employees, together with the right to grant and transfer all or a
portion of the same, all easements and rights for access, ingress, egress, encroachment,
maintenance, drainage, support, and for other purposes over the Association Maintenance Areas
and other portion of the Lot, reserved to Grantor in the following instruments:
1. The Amended and Restated Declaration of Covenants, Conditions and
Restrictions and Reservation of Easements for The Hideaway Owners Association (as amended
or supplemented, the "Declaration"), recorded onDECEMBER 13 , 2002, as Instrument No.
2002=
v -
f
i
2. All other covenants, conditions, restrictions, reservations, easements, rights and
/rights-of-way of record including, without limitation, the Declaration and the Map for Tract No.
29894-2
Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and
approves all of the foregoing in this Grant Deed, (b) grants to Grantor and The Hideaway
Owners Association such powers and rights as are set forth in the Declaration ,and (c) accepts,
covenants and agrees to be bound by and assume performance of all of the applicable provisions
and requirements set forth in the Declaration, including Section 3.15 establishing the procedure
for resolving disputes with Grantor, and. the notice, which provisions and requirements are
acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is
conditioned upon the performance of such provisions and requirements as are to be performed by
Grantee under the Declaration. The restrictions on use and occupancy of the Lot are set forth in
the Declaration to which this Grant Deed is specifically and expressly made subject.
GRANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING, granting unto
Grantor and The Hideaway Owners Association such powers and rights which are set forth in the
Declaration defined above;
STATE OF�.��.�Q„jl )
COUNTY
ss.
OF��,��'S�d e, )
Q�
On O. ,fit, before me, the undersigned, a notary public in and
for said State, personally appeared l Q r Q_ }gyp(' n personally known to me (or
proved to me on the basis of satisfactory evi ce) to be the person(s) whose names is
subscribed to the within instrument and acknowled ed to me thalh /shchhey executed the same
inQhetlffeir authorized capacity(ies), and that b ih' /herftheir-signature(s) on the instrument
the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument.'
WITNESS MY HAND AND OFFICIAL SEAL'.
Signature P --2k[SEAL]
IN0 ; ;.a 0 .3 Cl 8 : ,o,. of 5
I-LA/627969.1 4
r C:o tt cJi .::fur: K 1346326 z
Ca!i`cmia
z
>
7i^..
.. m—". ii, 2
AF :.DV- PIC;SSO-MOORE
C_ Ptni=�;irsn 1346326
z
n: -,ids County '
E. ier 11' 2C b
LI/
i' GOVERNMENT CODE 27361.7
i
jl I HEREBY CERTIFY UNDER PENALTY OF PERJURY THAT THE NOTARY SEAL ON
THE DOCUMENT TO WHICH THIS IS ATTACHED READS AS FOLLOWS:
NAME OF NOTARY: ARROW PICASSO-MOORE
DATE COMMISSION EXPIRES: MARCH 11, 2006
COMMISSION NUMBER: 1346326
COUNTY WHERE BONDED: RIVERSIDE
PLACE OF EXECUTION: RIVERSIDE COUNTY, CALIFORNIA
DATE: JANUARY 17, 2003
jp�jqj)M6
FIDELITY NATIONAL TITLE
BUILDER SERVICES
YOUNG ENGINEERING SERVICES
77-504 Wildcat Dr., Ste. C, Palm Desert, CA. 92211 (760) 360-5770 fax (760) 360-5719
January 16, 2004
Tom Hartung
Building Official
City of La Quinta
Re: Horn Residence, The Hideaway, Tract 29894-2, Lot 274, La Quinta, Ca
Dear Tom,
We have reviewed the truss calculations provided by Foxworth Galbraith Truss Company for the
above-mentioned project and find them to be in general conformance with our design intent.
If you have any questions please call.
C
J
VkX
No. 4044
Certificate of Occupancy-
U ��GI�Cv
Inmcoon�n�
c OF'LBuildin & Safet Department
9► Y_ p
This Certificate is issued pursuant to the requirements of Section 109 of the California Building
Code, certifying that, at the time of issuance, this structure was in compliance with the
provisions of the Building Code and the various ordinances of the City regulating building
construction and/or use.
q
BUILDING ADDRESS: 53-317 VIA PISA
Use classification: S.F.D. Building Permit No.: 0310-293
Occupancy Group: R-3 Type of Construction: V -N Land Use Zone: R -L
Owner of Building: JERRY HORN Address: PO.DRAWER 4656
City, ST, ZIP: PLAM DESERT CA 92261
By: G. SHOWALTER
Date: 08/26/05
- Building Official
POST IN A CONSPICUOUS PLACE
TANDrS '
INSPECTION INC.
PO BOX 13766
PALM DESERT, CA 92255
SPECIAL INSPECTION DAILY REPORT OFFICE/FAX 909.769.9717
PAGER 760.776.3339
TYPE OF INSPECTION PERFORMED
1��pm<k4
SAMPLE INFORMATION
I
TICKET NUMBER MIX NUMBER
DAT
I -k �_
PHYSICAL ADDRESS
PERMIT NUMBER
- -
-TY
09
JOB NAME
f
WELDING INFORMATION
OF`STRUCTURE
ARCHITECT
WELDERS NAME
ENGI ER
OC,l1.�,rG
GENERAL CONTRACTOR
SUB CONTRACTOR
S -T O kf ry S
OF WORK
I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK,
UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS
WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE
BUILDING LAWS.
CC:
INSPECTORS SIGNATURE
INSPECTORS CERTIFICATION AGENCY AND NUMBER
SAMPLE INFORMATION
SUPPLIER
TICKET NUMBER MIX NUMBER
TIME AIR TEMP SAMPLE
SAMPLED TEMP
SLUMP TIME IN MIXER
LOCATION
WELDING INFORMATION
PROCESS
WELDERS NAME
CERTIFYING AGENCY AND CERTIFICATION NUMBER
I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK,
UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS
WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE
BUILDING LAWS.
CC:
INSPECTORS SIGNATURE
INSPECTORS CERTIFICATION AGENCY AND NUMBER
SPECIAL INSPECTION DAILY REPORT
TAN DY'S
INSPECTION INC.
PO BOX 13766
PALM DESERT, CA 92255.3766
OFFICE/FAX - 909.769.9717
PAGER - 760.776.3339
DESCRIPTION OF WORK INSPECTED
5/3-5/4-5/5-5/6-5/7-5/10-5/11
OBSERVED SINGLE PASS AND COMPLETE JOINT PENETRATION WELDING ON COLUMNS AND BEAMS.
SEE ATTACHED FABRICATION REPORT.
SHOP WELDING COMPLETE
5/12 - COLUMNS 1 A & 1 B AND BEAM 3A CJP WELDS PASSED ULTRASONIC TESTING BY INLAND
INSPECTION.
5/27 - ALL FIELD CJP WELDS PASSED ULTRASONIC TESTING BY INLAND INSPECTION.
WELDING INFORMATION
DATE
TYPE OF INSPECTION PERFORMED
SHOP WELDING
CERTIFYING AGENCY AND CERTIFICATION NUMBER
27 -May -04
PHYSICAL ADDRESS
PERMIT NUMBER
53317 VIA PISA- LA QUI NTA
310293
JOB NAME
TYPE OF STRUCTURE
HORN RESIDENCE @ THE HIDEAWAY
SFD
ARCHITECT
ENGINEER
VISUAL FRONTIERS
YOUNG ENGINEERING
GENERAL CONTRACTOR
SUB CONTRACTOR
STEVEN JONES
WHITES STEEL
DESCRIPTION OF WORK INSPECTED
5/3-5/4-5/5-5/6-5/7-5/10-5/11
OBSERVED SINGLE PASS AND COMPLETE JOINT PENETRATION WELDING ON COLUMNS AND BEAMS.
SEE ATTACHED FABRICATION REPORT.
SHOP WELDING COMPLETE
5/12 - COLUMNS 1 A & 1 B AND BEAM 3A CJP WELDS PASSED ULTRASONIC TESTING BY INLAND
INSPECTION.
5/27 - ALL FIELD CJP WELDS PASSED ULTRASONIC TESTING BY INLAND INSPECTION.
I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK,
UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK INSPECTORS SIGNATU
TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING
LAWS' ICC 1111326 -
CC: - INSPECTORS CERTIFICATION AGENCY AND NUMBER
WELDING INFORMATION
PROCESS
FCAW - E71 T-8 & SMAW - E7018
WELDERS NAME
CERTIFYING AGENCY AND CERTIFICATION NUMBER
ELOY CHAVEZ
EARTH SYSTEMS #ES1275
ELISEO VASQUEZ
EARTH SYSTEMS #ES1038
LUIS TORRES
EARTH SYSTEMS #ES1242
GUADALUPE AMAVICA
EARTH SYSTEMS #ES1183
ISHMAEL AYALA
EARTH SYSTEMS #ES4001
I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK,
UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK INSPECTORS SIGNATU
TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING
LAWS' ICC 1111326 -
CC: - INSPECTORS CERTIFICATION AGENCY AND NUMBER
.a
STRUCTURAL STEEL SHOP WELDING FABRICATION REPORT
Job Name: H012U 1363. ® 'TC7 #t l O t:;AW A �( Contractor. S T&11C7 - c,)D�tl�
Engineer. Yo u IOL— Architect V t S u R L, EP -c t4-r'i E*,'S
"- -- Fabricated at testi i Ml S LS Start Date: 5 3 , 01f Finish Date: 5,T-11
a `f
All materials conform to approved plans, specifications, AISC, and AWS D1.1 unless noted.
• ACC in SINGLE PASS or CJP WELDING columns represents acceptable welding and no corrective work required.
NDT stands for Non -Destructive Testing such as Ultrasonic or Magnetic Particle
om�o
M
EMMEM
mmm
MMEMINEM
mmm
M
wmm�
m0�u�m�
OM
mm
mmmm
i
MM
B=
mm
All materials conform to approved plans, specifications, AISC, and AWS D1.1 unless noted.
• ACC in SINGLE PASS or CJP WELDING columns represents acceptable welding and no corrective work required.
NDT stands for Non -Destructive Testing such as Ultrasonic or Magnetic Particle
TANDY'S
---- INSPECTION INC.
PO BOX 13766
PALM DESERT, CA 92255
OFFICE/FAX 909.769.9717
SPECIAL INSPECTION DAILY REPORT PAGER 760.776.3339
TYPE OF INSPECTION PERFORMED
JDATE t
PHYSICAL ADDRESS
50-3``t —
PERMIT NUMBER
031 61.1a3
JOB NAME
TYPE OF STRUCTURE
ARCHITECT
ENGINEER
S—%lC-:7-JE 30aJE
GENERAL CONTRACTOR
SUBCONTRACTOR
DESCRIPTION OF WORK INSPECTED
u W ELbr-
'�:
�� ui .E_ uta
1
SAMPLE INFORMATION
SUPPLIER TICKET NUMBER MDL NUMBER SAMPLED MP TEMP STEMFE SLUMP TIME IN MIXER
LOCATION
WELDING INFORMATION
PROCESS tA41 W
WELDERS NAME CERTIFYING AGENCY AND CERTIFICATION NUMBER
ZyI- . co TA ruts oc� -3a.
I HERESY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK
UNLESS OTHEJiWM NOTED. MID TO THE BEST OF MY ABILITY I HAVE POUND THIS NS ORS SIGNATURE
WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS 6 HPPUCABLE q
SUILOM LAWS. G.1 !i_=--
INSPE TORS CERTIFICATION AGENCY AND NUMBER
CC:
tg%i
TANDY'S
INSPECTION INC.
PO BOX 13766
PALM DESERT. CA 92255
SPECIAL INSPECTION DAILY REPORT OFFICE/FAX909.769.9717
PAGER 760.776.3339
TYPE OF INSPECTION PERFORMED
SAMPLE INFORMATION
DATE
of
AIR TEMP
8AMPLED
,
,t
PHYSICAL ADDRESS
S'o - 31� PrS�4
PERMIT NUMBER
b31 OAS
'O` NAME
TYPE OF STRUCTURE
i O o.j LA
�j L
ARCHITECT
ENGINEER
S -i -EVE' �,wE
GENERAL CONTRACTOR
SUB CONTRACTOR
yG
1 HEREBY CERTIFY THAT 1 HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK,
UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY 1 HAVE FOUND THIS
WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS 8 APPLICABLE
BUILDING LAWS.
CC:
�.PECTORS SIGNATURE
_Jr -c I?G ht-ec
INSPECTORS CERTIFICATION AGENCY AND NUMBER
SAMPLE INFORMATION
SUPPLIER TICKET NUMBER
MIX NUMBER
AIR TEMP
8AMPLED
SAMPLE SLUMP TIME IN MIXER
TEMP
LOCATION
WELDING INFORMATION
PROCESS
WELDERS NAME
CERTIFYIN AGENCY AND CERTIFICATION NUMBER
yG
1 HEREBY CERTIFY THAT 1 HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK,
UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY 1 HAVE FOUND THIS
WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS 8 APPLICABLE
BUILDING LAWS.
CC:
�.PECTORS SIGNATURE
_Jr -c I?G ht-ec
INSPECTORS CERTIFICATION AGENCY AND NUMBER
vM
w
01/04/2005 09:09 17603401819
PARAGON/SCHMID BUILDING PRODUC'T'S
MAIL TO: 74-741 JONI DRIVE #A
PALMDESERT, CA 92660
�I 760-346-2339 X117 FAX 760-340.1919
iALIRERSOIVAL
ATTN: ED RANDA LL (BUILDING DE"
COMPANY: STF,PHE.'' JONS CONSTRUCTION
FAX NUMBER: 777 7011
PHONE NUMBER:
DATE: 1/4/2005
FROM: VOLANDA CANT
PIlONE:760-346-23:;9 X117
FAX: 760-340-1819
E -Mail: yolanila.gant@nmascocs.com
TOTAL OF PAGES IN FAX INCLUDMQ COVER PAGE:
YOUR REFERENCE, r- IJMBER,TROJECT: PIE
X URC -ENT X PLEASE RESPOND
[HERBS THE INSULA'I IiON CERTIFICATES THAT YOU WERE REQUESTING, IF YOU HAVE, ANY
IQUFSTIONS PLEASE AVE MR A CALL, MY NUMBER IS LOCATED AT THE TOP OF T HIS FAX.
(I'LL PUT YOUR ORI(: INAL$ IN THE MAIL.
keep me up Bated (in the status of the invoice(s).
1,
I APPRECIATE ALL OF YOUR HELP:) O ��
Ydiee FAX COVER
PAGE 01/02
U
TITLE 24 REPORT
Title 24 Report for:
Horn Residence
Lot 274 The Hideaway
La Quinta, CA 92253
Project Designer:
Stephen Jones Design & Construction, Inc.
P.O. Drawer 4656
Palm Desert, CA 92260
(760) 346-3366
Report Prepared By:
C.J. Mcfadden
BREEZE AIR CONDITIONING
75-145 ST. CHARLES PLACE
PALM DESERT, CA 92211
(760) 346-0855
CITY OF LA �UioEPA
Job Number: BUILDING & SA
AP oR0!/EID
0004.00 FOR C
DATE tON
BY
Date:
1/15/2004
f
r -The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
. authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC (415) 883-5900.
EnergyPro 3.1 By EnergySoft Job Number: 0004.00 User Number: 3665
Ss 4p %5D Zoa C8C..'
Certificate of Compliance: Residential
(Part 1 of 2) CF -1 R
Horn Residence
1/15/2004
Project Title
Date
Lot 274 The Hideaway La Quinta
Exterior Roof
Project Address
Building Permit #
BREEZE AIR CONDITIONING (760) 346-0855 Plan Check/Date
Documentation Author Telephone
Solid Wood Door
Computer Performance 15
Field Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Wood
Total Conditioned Floor Area: 7,277 ft2 Average Ceiling Height: 11.1 ft
Total Conditioned Slab Area: 7,038 ft2
Slab On Grade
Building Type:
0.756
(check one or more)
Slab On Grade
X❑ Single Family Detached ❑ Addition
0.756
❑ Single Family Attached ❑ Existing Building
Front
❑ Multi -Family ❑ Existing Plus Addition
59.3
Front Orientation: (Northeast) 45 deg Floor Construction Type:
® Slab Floor
Number of Dwelling Units: 1.00
ScreenX❑
Number of Stories: 3
® Raised Floor
w
0
Component
Vie_
Frame
Type
Const.
Assembly
U -Value
Location/Comments
(attic, garage, typical, etc.)
R-38 Roof (R.38.2xl4.16)
Wood
0.027
Exterior Roof
R-23 Certinty (blown in) Wall
Wood
0.057
Exterior Wall
Solid Wood Door
Wood
0.387
Exterior Door
R-23 Certinty (blown in) Wall (W-2)
Wood
0.064
Exterior Wall
Slab On Grade
n/a
0.756
Exposed Slab w/R-0.0 Perimeter Insulation
Slab On Grade
n/a
0.756
Covered Slab WR -0.0 Perimeter Insulation
R-30 Floor (F.30.2x10.16) Wood 0.034 Exterior Floor / Over Open Space
FENESTRATION
Shading Devices
Type
Orientation
Area
Fenestration
Exterior
Overhang Side Fins
SF
U -Factor
SHGC
Shading
Yes / No
Yes
/ No
Right
(North)
13.5
0.44
0.26
Bug
Screen
X❑
❑
❑
X❑
Front
(Northeast)
59.3
0.44
0.26
Bug
ScreenX❑
❑
❑
X❑
Front
(East)
58.5
0.44
0.26
Bug
Screen
X❑
❑
❑x❑
Left
(South)
10.5
0.44
0.26
Bug
Screen
X❑
❑
❑
X❑
Rear
(West)
55.7
0.44
0.26
Bug
ScreenX❑
❑
❑X❑
Front
(Northeast)
474.4
0.38
0.42
Bug
Screen[i]
❑
❑X❑
Left
(Southeast)
70.6
0.44
0.26
Bug
Screen
X❑
❑
❑X❑
Left
(Southeast)
381.0
0.38
0.42
Bug
Screen
X❑
❑
❑
X❑
Left
(South)
160.0
0.38
0.42
Bug
Screen
X❑
❑
❑
X❑
Rear
(Southwest)
44.5
0.44
0.26
Bug
Screen
x❑
❑
❑X❑
Rear
(Southwest)
300.0
0.38
0.42
Bug
Screen
x❑
❑
❑
X❑
Right
(Northwest)
62.3
0.44
0.26
Bug
ScreenX❑
❑
❑
X❑
Run Initiation Time: 01/15/04 08:12:10 Run Code: 1074183130
Ener
Pro 3.1 By Ener
Soft
User Number: 3665
Job Number: 0004.00
Pa e:3 of 53
Certificate of Compliance: Residential
(Part 2 of 2) CF -1 R
Horn Residence
1/15/2004
• Project Title
Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum
Type and
Duct or
Type (furnace, heat Efficiency
Location
Piping
Thermostat Location /
pump, etc.) (AFUE/HSPF) (ducts, attic, etc.)
R -Value
Type
Comments
Central Furnace 80% AFUE
Ducts in Attic
6.0
Setback
HVAC -7
Cooling Equipment Minimum
Duct
Type (air conditioner, Efficiency
Location
Duct
Thermostat Location /
heat pump, evap. cooling) (SEER)
(attic, etc.)
R -Value
Type
Comments
Split Air Conditioner 16.0 SEER
Ducts in Attic
60
Setback
HVAC -7
WATER HEATING SYSTEMS
Rated 1
Tank
Energy Facts 1 External
Water Heater Water Heater
Distribution # in
Input
Cap.
or Recovery Standby Tank Insul.
System Name Type
Type Syst. Btu/hr
(gal)
Efficiency Loss (%) R -Value
LJ
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storace water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: Name: C.J. Mcfadden
Title/Firm: Stephen Jones Design & Construction, Inc. Title/Firm: BREEZE AIR CONDITIONING
Address: P.O. Drawer 4656
Palm b sertCA 92260
Telephone: 760 34.6-3366 11
Lic. #:'S -L- p -Ic
:A�-
(signatur6)------'(date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
Address: 75-145 ST. CHARLES PLACE
PALM DESERT, CA 92211
Telephone: (760) 346-0855
1 15 p
(signature (date)
IEnergyPro 3.1 By EnergvSoft User Number: 3665 Job Number: 0004.00 Page:5 of 53 1
Certificate of Compliance: Residential (Addendum) CF -1 R
Horn Residence 1/15/2004
•Project Title Date
+Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. I Plan I Field
40
Ll
The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
The HVAC System "HVAC -2" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -2" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 964 sqft Tile in Mortar Interior Mass, 0.75" thick at First Floor
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 964 sqft Exposed Slab Floor, 4.00" thick at First Floor
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 241 sqft Covered Slab Floor, 4.00" thick at First Floor
The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
The HVAC System "HVAC -3" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -3" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 165 sqft Tile in Mortar Interior Mass, 0.75" thick at HVAC -3
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 165 sqft Exposed Slab Floor, 4.00" thick at HVAC -3
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. I Plan I Field
The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC -2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC -3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC -3" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC -4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
Ir
The HVAC System "HVAC -4" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC -5" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
Run Initiation Time: 01/15/0408:12:10 Run Code: 1074183130
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:6 of 53
Certificate of Compliance: Residential (Addendum) CF -1 R
Horn Residence 1/15/2004
•Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. i—PlanIField
•
i�
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 663 sqft Covered Slab Floor, 4.00" thick at HVAC -3
The HVAC System "HVAC -4" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
The HVAC System "HVAC -4" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -4" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -4" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 698 sqft Tile in Mortar Interior Mass, 0.75" thick at HVAC -4
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 698 sqft Exposed Slab Floor, 4.00" thick at HVAC -4
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1046 sqft Covered Slab Floor, 4.00" thick at HVAC -4
The HVAC System "HVAC -5" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
The HVAC System "HVAC -5" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -5" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -5" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1359 sqft Tile in Mortar Interior Mass, 0.75" thick at HVAC -5
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. I Plan I Field
The HVAC System "HVAC -5' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC -6" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC -6" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC -7" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC -7" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
Run Initiation Time: 01115/0408:12:10 Run Code: 1074183130
EnergyPro 3.1 By Energysoft User Number: 3665 Job Number: 0004.00 Page:7 of 53
Certificate of Compliance: Residential (Addendum) CF -1 R
Horn Residence 1/15/2004
.Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. I Plan I Field
lu
•
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1359 sqft Exposed Slab Floor, 4.00" thick at HVAC -5
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 239 sqft Covered Slab Floor, 4.00" thick at HVAC -5
The HVAC System "HVAC -6" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
The HVAC System "HVAC -6" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -6" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -6" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 941 sqft Tile in Mortar Interior Mass, 0.75" thick at HVAC -6
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 941 sqft Exposed Slab Floor, 4.00" thick at HVAC -6
HIGH MASS Design(see C -21R) - Verify Thermal Mass: 95 sqft Covered Slab Floor, 4.00" thick at HVAC -6
The HVAC System "HVAC -7" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
The HVAC System "HVAC -7" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -7" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -7" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC aooroved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures ori a form CF -6R. Plan Field
Run Initiation Time: 01/15/0408:12:10 Run Code: 1074183130
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:8 of 53
Certificate of Compliance: Residential (Addendum) CF -1 R
Horn Residence 1/15/2004
•Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
0
•
)aseo on the aaequacy of the special jusuncation ano aocumentation sunmittea. Plan Field
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 627 sqft Covered Slab Floor, 4.00" thick at HVAC -7
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures ori a form CF -6R. plan Field
Run Initiation Time: 01/15/04 08:12:10 Run Code: 1074183130
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:9 of 53
•
0
•
Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Building Envelope Measures
1150(a): Minimum R-19 ceiling insulation.
§150(b): Loose fill insulation manufacturer's labeled R -Value.
❑X "§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
not apply to exterior mass walls).
❑ ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.
§150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no
❑
greater than 2.0 perm/inch.
a§118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§ 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
❑X
§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
Al §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
E] §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
§150(i): Setback thermostat on all applicable heating and/or cooling systems.
FX §1500): Pipe and Tank Insulation
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 10 of 53
Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R
140TE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (") may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
• the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
•
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
FX]'§ 150(m): Ducts and Fans
t
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
duct tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of the material.
❑ § 114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance
heating, and no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or
spas.
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
RI§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
❑ §118 (f): Cool Roof material meet specified criteria
Lighting Measures
§150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved.
3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 11 of 53
Computer Method Summary (Part 1 of 3) C -2R
_dorf3-Residence
2.77
1 /15120-04
Title
3.92
Date
�Project
1ot 274 Th cleawa_y-La_Q_uinta
37.07
-0-057 90 90
Project Address
00.57 94 90
Building Permit #
BBEEZEAIB_CONDI_T_l_QN.LNG
(760) 346-0855
0057 -2.7.0. 90
Documentation Author
Telephone
pian Check/Date
Computer�elfolmanCe
15
0034 0 080
Field Check/Date
Compliance Method (Package or Computer)
Climate Zone
-(_05.1 0 9.0_
Source Energy Use Standard
Proposed Compliance
Wall_ 3.fa
(kBtu/sf-yr) Design
Design Margin
0 057 X30 90
Space Heating
Space Cooling
Domestic Hot Water
Totals
ard:
Total Conditioned Floor Area:
Building Type:
Building Front Orientation:
Number of Dwelling Units:
Number of Stories:
4.04
2.77
33.67
29.07
3.92
5.23
41.63
37.07
-0-057 90 90
Wall- 8.5
00.57 94 90
BUILDING I
BUILDING ZONE INFORMATION
Zone Name
•riva�-4
JiVAC_5
7,277 ft2
Single Fam Detached
(Northeast) 45 deg
1.00
3
OPAQUE SURFACES Act.
Type Area U -Fac. Azm. Tilt
Floor Area Volume
Rooms 1167 0- 21 340 0
Wall- _54-
-0-057- 0 _90_
Door 24
_0_3.87_ _0_ _90
Wall_ ____JAQ
0..464_ 0 90
Wall_ _224
-0-057 90 90
Wall- 8.5
00.57 94 90
Wall- 58
0064 080 _90
Wall- X30
0057 -2.7.0. 90
DO.or 24
_09.87 270 90
Wall- x.50_
_0_0-64. 37.0 ---9.0-
-Boor--- ____38_
0034 0 080
_Boni__201
0927_ 3A0 0
Wall- 3.6_
-(_05.1 0 9.0_
Wall- 47
0.057 45 90_
Wall_ 3.fa
-O-G57- 90 90_
Wall_ 47
0 057 X30 90
Wall_ 36_
-0-0.5.7- 08.0 90
Wall_ 47
_Q..Q5.7- -225 90
Wall- 36
-0-037- 310--99
Wall- 47
0-457 310 90
Floor _2.01
0-.034 0 ---180-
80Root
Roof-8211
_0_027- -340 _0_
Wall_ _20-
0 057 ___A5_ 90_
Wall- 92
00.57 035. 90_
Wall- _280
-(_0.57 -225 90_
Root- x..744
-0-02.7- 3A0 0
Wall_ _2.94
0.064- 0 _90-
0Wall-
Wall-47
001 080 90
Wall- 56
0057 320 90
1 444
828
1,744
1.598
Solar
Gains
Y/N
__1U2_4
12.420
1-8,66-1
19.17_6
1.28
4.60
-1.32
4.56
11.0%
Floor Construction Type: 0 Raised Floor XI Slab Floor
Total Fenestration Area: 23.2%
Total Conditioned Volume: 81,130 ft 3
Total Conditioned Slab Area: 7,038 ft 2
# of Thermostat Vent
Units Zone Type Type Hgt. Area
-020_ 1 iv" g -I ivingS.tat- 8 -n a
0"11 Living_LivingSlat- 8 _n/a
024- Sleeping -Sle ping.Slat_ 8 _n/.a
-0-22- Living I iving_Stat__ 8 _nLa
Form 3 Reference
g38_R0J (&38 14..1.6.)
R 23_C etf i nty�blo w� i n)-1 N a I I
_S.olid Wood -Door
B_2 C�rtinty (bloyxn in) WaILCW-2)
_R-23_Cettinty_(blown tn) Wal I
R-23 Ce�finty (blown i Wall
B23�e�tinty�blownin)_WaIW I rW-2j_
B23_Celfiaty�blo�yn in) Wall
_SoJkLWood_D9nr
R23 Cedinty (blown in Wall (W-22)
R30_R0oL(E 30 2x1016)
_B_38Roof (R )S_2x14.16)
R-23 Certinty (blown in) Wall
R23_Certinty_(b1ownin)_Wal I
R23_Cei"_(Wown in) Wall
R23 Ce�inty (blown in) Wall
-R--23-C (blown in) Wall
R23_Cer intMblow.n in) Wall
R23_Cediaty_(b1own W_WAlI
R23_CeAinty_(Wmn in) Wall
_B_30_FJ.OJDL(E.34.2xM_6.)
R38Roof IR.382x14.1A
R23_Ce.�3inty (blown�n) V1Call
R23 Ce�3inty�blown in) all
R23_Ce6nty_(blawn in,) Wall
R38Boof (R.302xL416)
R23 Celfinty.jblown in) WAUWzZ
R23_C2lfinty_( all
JiVAC-2
HV C_9
HVA_ C-2
H r-2
HV C-2
H C-9
HVAr-2
JiVAC-2
H C-2
H C-2
H C-2
JiVAC-2
JTV.AC-2
H -2
HVAC -2
JivAr.-2
.kLVAC-2
HVAC -3
H r'-3
J±VAG3
Location / Comments
EnergyPro 3.1 By EnergvSoft User Number: 3665 Job Number: 0004.00 Page:12 of 53
Computer Method Summary (Part 1 of 3) C -2R
_I.orn_Residenne
1/15120-04
Title
Solar
OPAQUE SURFACES
Date
WProject
lo _27A The — Hideaway La_Quinta
Type Area
U -Fac. Azm. Tilt
Y / N
Project Address '
—0-057- —27-0 _90-
0Wall—
Building Permit #
BREEZE AIR CONDITIONING
-Wall 40
(760) 346-0855
Documentation Author
Telephone
Plan Check/Date
Comute�elfomlance
15
Roof— x...598
Field Check/Date
Compliance Method (Package or Computer)
Climate Zone
-Wall _12.9
Source Energy Use Standard
Proposed
Compliance
❑
(kBtu/sf-yr) Design
Design
Margin
IN
Space Heating 4.04
2.77
1.28
Space Cooling 33.67
29.07
4.60
—0-0-0-057-O�—315 —90
Domestic Hot Water 3.92
5.23
-1.32
Roof— 036_
Totals 41.63
37.07
4.56
❑
than Standard:
11.0%
Total Conditioned Floor Area: 7,277 ft Floor Construction Type: X❑ Raised Floor ❑X Slab Floor
Building Type: Single Fam Detached
Building Front Orientation: (Northeast) 45 deg Total Fenestration Area: 23.2%
Number of Dwelling Units: 1.00 Total Conditioned Volume: 81,130 ft 3
Number of Stories: 3 Total Conditioned Slab Area: 7,038 ft 2
BUILDING ZONE INFORMATION # of Thermostat Vent
Zone Name Floor Area Volume Units Zone Type Type Hgt. Area
HVAC_6 x.,.03.6 —.0153 0 14 Living _LivingS1at— 8 n/a
.H_V.AC 7 627_ —6,8.97 _0_0.9_ Living _LLvingS.tat_ 8 _nLa
•
W_al.l_ 358 0057 035 90 LA_ LJ
Wall— 158 —0-057- —22.5 _9A IX ❑
.Roo(— 627- 0.027 —345 0 X ❑
Wall_ 6.0 —0-05L 45 9.0 [X ❑
Wall_ 240_ _0_057- —225 90_ 6a ❑
Wall_ 300 0.0.52 —315 90_ D_Q ❑
_Door 24 0_387- —315 90_ [)Q ❑
Form 3 Reference
R_23 Certinty ((blown in) Wall
R23-Cettinty (blown-n)_WalL(W2)_
R23_Ce rtinty_(blow.n_ n)_Wall.
R38Boof_(R_3&2x14.1&)
B-23_CeAintk(blown.in) \tVall
R23_CerSinty_(blawn inl Wall
R23_Ce_tinty_(b1own in)1Nall
R23_CertiriW blownin)_l_V_al I
JR-3.8-Roof-(R38.2x1_4 l61
R23_.eA ty_(blon i Wall
B23_sri1ilown i ) Wall(W-2-2)
823 CedbWblownin) Wall
R-23 Certinty ((blown in) Wall
B 38Boof (R. 38.2x14_].6.)
R-23 Cerin (blown i all
R23_Ce_dintk(b1ownin) Wall
B-23S�ettinty (blown in)_Vfiall
1.01id 1L1/oodJZoor
Location / Comments
HVAC -4
HVAG_5
xVAC_5
HVAC -6
-6
HVAC -6 .IiVAC_6
HVA •=6
HVAC_6
HVAC -7
HVAC -7
_7
HVA
HVAG_7
IiVAC-7
I EneravPro 3.1 By EneravSoft User Number: 3665 Job Number: 0004.00 Paae:13 of 53 1
Solar
OPAQUE SURFACES
Act.
Gains
Type Area
U -Fac. Azm. Tilt
Y / N
Wall_ 26Z
—0-057- —27-0 _90-
0Wall—
-Wall 40
0_064_ —2.7-0 --90-
90Wall_
-Wall-40
—0-057- —315 90_
❑
Roof— x...598
0_022 XA5_ —0-
0Wall_
-Wall _12.9
—0-057-4.5 90
❑
Wall_ X04
—0-057- 035 90_
IN
❑
Wall_ 241
---0-057- X2.5 90
[
❑
-Wall 338
—0-0-0-057-O�—315 —90
X
❑
Roof— 036_
0-027- _3A5_ 0_
❑
Wall —249
0 057 ___A5 90
Wall_ 32
0-06A- 45 90
❑
•
W_al.l_ 358 0057 035 90 LA_ LJ
Wall— 158 —0-057- —22.5 _9A IX ❑
.Roo(— 627- 0.027 —345 0 X ❑
Wall_ 6.0 —0-05L 45 9.0 [X ❑
Wall_ 240_ _0_057- —225 90_ 6a ❑
Wall_ 300 0.0.52 —315 90_ D_Q ❑
_Door 24 0_387- —315 90_ [)Q ❑
Form 3 Reference
R_23 Certinty ((blown in) Wall
R23-Cettinty (blown-n)_WalL(W2)_
R23_Ce rtinty_(blow.n_ n)_Wall.
R38Boof_(R_3&2x14.1&)
B-23_CeAintk(blown.in) \tVall
R23_CerSinty_(blawn inl Wall
R23_Ce_tinty_(b1own in)1Nall
R23_CertiriW blownin)_l_V_al I
JR-3.8-Roof-(R38.2x1_4 l61
R23_.eA ty_(blon i Wall
B23_sri1ilown i ) Wall(W-2-2)
823 CedbWblownin) Wall
R-23 Certinty ((blown in) Wall
B 38Boof (R. 38.2x14_].6.)
R-23 Cerin (blown i all
R23_Ce_dintk(b1ownin) Wall
B-23S�ettinty (blown in)_Vfiall
1.01id 1L1/oodJZoor
Location / Comments
HVAC -4
HVAG_5
xVAC_5
HVAC -6
-6
HVAC -6 .IiVAC_6
HVA •=6
HVAC_6
HVAC -7
HVAC -7
_7
HVA
HVAG_7
IiVAC-7
I EneravPro 3.1 By EneravSoft User Number: 3665 Job Number: 0004.00 Paae:13 of 53 1
Computer Method Summary (Part 2 of 3) C -2R
Horn Residence 1/15/2004
AlkProiect Title Date
FENESTRATION SURFACES
#
Type
0.76
0.0
Area
Ll-
Factor
SHGC
Act.
Azm.
Glazing Type
Tilt
2
-1-
Window Riaht(Notth)
-3_0
_0940-
_0.26_
0_
-90 Assumed_Glassing values
2
Window
Front
(Northeast)
12.5
0.440
0.26
45
90 Assumed Glassing
values
3
Window
Front
(Northeast)
3.0
0.440
0.26
45
90 Assumed Glassing
values
4
Window
Front
(Northeast)
7.5
0.440
0.26
45
90 Assumed Glassing
values
5
Window
Front
(Northeast)
25.0
0.440
0.26
45
90 Assumed Glassing
values
6
Window
Front
(Northeast)
7.5
0.440
0.26
45
90 Assumed Glassing
values
7
Window
Front
(East)
3.0
0.440
0.26
90
9Q Assumed Glassing
values
8
Window
Front
(East)
45.0
0.440
0.26
90
90 Assumed Glassing
values
9
Window
Right
(North)
10.5
0.440
0.26
0
90 Assumed Glassing
values
10
Window
Front
(East)
10.5
0,444
0.26
90
90 Assumed Glassing
values
11
Window
Left
(South)
10.5
0.440
0.26
180
90 Assumed Glassing
values
12
Window
Rear
(West)
10.5
0.440
0.26
270
90 Assumed Glassing
values
13
Window Front_(Uodh-east)
20.8
-O-$Q
0.42
4,5-
9Q Ass_umed_Glassina values
14
Window
Front
(Northeast)
20.8
0.380
0.42
45
90 Assumed Glassing
values
15
Window
Front
(Northeast)
20.8
0.380
0.42
45
90 Assumed Glassing
values
16
Window
Front
(Northeast)
108.0
0.380
0.42
45
90 Assumed Glassing
values
17
Window
Front
(Northeast)
108.0
0.380
0.42
45
90 Assumed Glassing
values
18
Window
Front
(Northeast)
108.0
0.380
0.42
45
90 Assumed Glassing
values
19
Window
Left
(Southeast)
20.8
0.440
0.26
135
9Q Assumed Glassing
values
20
Window
Left
(Southeast)
20.8
0.440
0.26
135
90 Assumed Glassing
values
21
Window
Left
(Southeast)
108.0
0.380
0.42
135
90 Assumed Glassing
values
22
Window
Left
(Southeast)
108.0
0.380
0.42
135
90 Assumed Glassing
values
23
Window
Left
(South)
80.0
0.380
0.42
180
90 Assumed Glassing
values
24
Window
Left
(South)
80.0
0.380
0.42
180
90 Assumed Glassing
values
25
Window
Rear
(Southwest)
6.0
0.440
0.26
225
90 Assumed Glassing
values
26
Window
Rear
(Southwest)
32.5
0.440
0.26
225
90 Assumed Glassing
values
27
Window
Rear
(Southwest)
6.0
0.440
0.26
225
90 Assumed Glassing values
28
Window
Rear
(West)
25.2
0.440
0.26
270
90 Assumed Glassing values
29
Window
Rear
(West)
20.0
0.440
0.26
270
90 Assumed Glassing
values
INTERIOR AND EXTERIOR SHADING
Window
Overhang_
Left Fin
#
Exterior
Shade
Type
SHGC
Hgt.
Wd.
Len. Hgt. LExt. REA Dist. Len. He
1
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
2
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
3
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
4
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
5
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
6
Bug Screen
0.76
0.0
0.0
0.0 0.0 0.0 0,0
7
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
8
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
9
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
10
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
11
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
12
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
13
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
14
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
15
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
16
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
17
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
18
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
19
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
20
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
21
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
22
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
23
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
24
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
25
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
26
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
27
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
1028
29
Bug Screen
0.76
0.0
0.0
0.0
0.0
0.0
0.0
Location/
Comments
HVAC -2
HVAC -2
HVAC -2
HVAC -2
HVAC -2
HVAC -2
HVAC -2
HVAC -2
HVAC -2
HVAC -2
HVAC -2
HVAC -2
HVAC -3
HVAC -3
HVAC -3
HVAC -3
HVAC -3
HVAC -3
HVAC -3
HVAC -3
HVAC -3
HVAC -3
HVAC -4
HVAC -4
HVAC -4
HVAC -4
HVAC -4
HVAC -4
HVAC -4
Dist.
EnergvPro 3.1 By EnergvSoft User Number: 3665 Job Number: 0004.00 Paae:14 of 53 1
Computer Method Summary (Part 2 of 3) C -2R
Horn Residence 1/15/2004
Project Title Date
- FENESTRATION SURFACES
# Type
Area
U-
Factor
SHGC
Act.
Azm.
Glazing Type
Tilt
Location/
Comments
_3.0.
Window_Ero�t (Northeast)
_a8A
_0_3.8D
-0_42.
fib_
_9.0 Assumed -Glassing values
J•iVAC_5
31
Window Front
(Northeast)
3.8
0.440
0.26
45
90 Assumed Glassing
values
HVAC -5
32
Window Left
(Southeast)
29.0
0.440
0.26
135
90 Assumed Glassing
values
HVAC -5
33
Window Left
(Southeast)
120.0
0.380
0.42
135
90 Assumed Glassing
values
HVAC -5
34
Window Left
(Southeast)
22.5
0.380
0.42
135
90 Assumed Glassing
values
HVAC -5
35
Window Left
(Southeast)
22.5
0.380
0.42
135
90 Assumed Glassing
values
HVAC -5
35
Window Rear
(Southwest)
180.0
OMOL
0.42
225
90 Assumed Glassing
values
HVAC -6
37
Window Rear
(Southwest)
120.0
0.380
0.42
225
90 Assumed Glassing
values
HVAC -6
38
Window Right
(Northwest)
11.0
0.440
0.26
315
90 Assumed Glassing
values
HVAC -7
39
Window Right
(Northwest)
22.0
0.440
0.26
315
90 Assumed Glassing
values
HVAC -7
40
Window Right
(Northwest)
11.0
0.440
0.26
315
90 Assumed Glassing
values
HVAC -7
41
Window Right
(Northwest)
6.0
0.440
0.26
315
90 Assumed Glassing
values
HVAC -7
_4.2
Window-Right_nottbmst)
---6-0-
-O-44Q
0.25
315
90 Assumed Glassing values
HVAC -7
43
Window Right
(Northwest)
6.3
0.440
0.26
315
90 Assumed Glassing
values
HVAC -7
INTERIOR AND EXTERIOR SHADING
Window
Overhang
Left Fin
Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt.
30
Bug Screen
0.76
0.0
0.0
0.0
0.0 0.0 0.0
31
Bug Screen
0.76
0.0
0.0
0.0
0.0 0.0 0.0
32
Bug Screen
0.76
0.0
0.0
0.0
0.0 0.0 0.0
33
Bug Screen
0.76
0.0
0.0
0.0
0.0 0.0 0.0
34
Bug Screen
0.76
0.0
0.0
0.0
0.0 0.0 0.0
35
Bug Screen
0.76
0.0
0.0
0.0 0.0 0.0 00
36
Bug Screen
0.76
0.0
0.0
0.0
0.0 0.0 0.0
37
Bug Screen
0.76
0.0
0.0
0.0
0.0 0.0 0.0
38
Bug Screen
0.76
0.0
0.0
0.0
0.0 0.0 0.0
39
Bug Screen
0.76
0.0
0.0
0.0
0.0 0.0 0.0
40
Bug Screen
0.76
0.0
0.0
0.0
0.0 0.0 0.0
41
Bug Screen
0.76
0.0
0.0
0.0
0.0 0.0 0.0
42
Bug Screen
0.76
0.0
0.0
0.0
0.0 0.0 0.0
43
Bug Screen
0.76
0.0
0.0
0.0
0.0 0.0 0.0
Run InitiationTime: 1 l 4 :12:1 Run Code: 1074183130
EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: 0004.00 Page: 15 of 53
Computer Method Summary
Length
(Part 3 of 3) C -2R
Insulation
R -Val. Depth
Location / Comments
Slab Perimeter
Horn Residence
0.76
0.0
0
HVAC -2
Slab-P-ei imeier
1/15/2004
ANNILProiect Title
—0-0
0
HVAC -2
Slab Perimeter
08
Date
THERMAL MASS FOR HIGH MASS DESIGN
0
HVAC -3
Slab_P_erimeier
8 .
Area
Thick.
Heat
liVgC-3
Inside
Location
Type
(sf)
(in.)
Cap.
Cond. Form 3 Reference
R -Val.
Comments
Tile in Mortar
_9.64
015
_24
_0_67- N.a
0.
HVAC2/ Interio�llass
Concrete, Heavyweight
964
4_00
28
0_98 n/a
0
HVAC -2 / Slab on Grade
Concrete, Heavyweight
241
4.00
28
0.98 n/a
2
HVAC -2 / Slab on Grade
Tile in Mortar
165
0_75
24
0_67 n/a
0
HVAC -3 / Interior Mass
C-oJ1cLe1e,_lieaMeiaht
165
4.00
28
0.98 n/a
0
HVAC -3 / Slab on Grade
PERIMETER LOSSES
Type
Length
F2
Factor
Insulation
R -Val. Depth
Location / Comments
Slab Perimeter
71
0.76
0.0
0
HVAC -2
Slab-P-ei imeier
_2.4
-O-Z6
—0-0
0
HVAC -2
Slab Perimeter
08
0.76
0.0
0
HVAC -3
Slab_P_erimeier
8 .
0-Z6
—0-0
0
liVgC-3
Slab-Eetimeter
�1
0.76
0.0
0
HVAC -4
HVAC SYSTEMS
Heating Equipment
Minimum
Distribution Type
Type (furnace, heat
Efficiency
and Location
Duct Thermostat
Location /
pump, etc.) (AFUE/HSPF)(ducts/attic,
etc.)
R -Value Type
Comments
Central Furnace
80° AFUE
Ducts in Attic
6.0 Setback
HVAC -2
Central Furnace
80%AFUE
Ducts in Attic
6.0 Setback
HVAC -3
Central Furnace
80%AFUE
Ducts in Attic
6.0 Setback
HVAC -4
Central Furnace
80%AFUE
Ducts in Attic
6.0 Setback
HVAC -5
Hydronic Piping Pipe
Pipe
Insul.
System Name Length
Diameter Thick.
Cooling Equipment
Minimum
Duct
Type (air conditioner,
Efficiency
Location
Duct Thermostat
Location /
heat pump, evap. cooling)
(SEER)
(attic, etc,)
R -Value Type
Comments
Split Air Conditioner
15.0 EER
Ducts in Attic
6.0 Setback
HVAC -2
Split Air Conditioner
15.0 SEER
Ducts in Attic
6.0 Setback
HVAC -3
Split Air Conditioner
15.0 SEER
Ducts in Attic
6.0 Setback
HVAC -4
Split Air Conditioner
15.0 SEER
Ducts in Attic
6.0 Setback
HVAC -5
WATER HEATING SYSTEMS
Rated' Tank
Energy Fact!
1 Tank Insul.
Water Heater
Water Heater Distribution
# in Input Cap.
or Recovery
Standby R -Value
System Name
Type
Type
Syst. (Btu/hr) (gal)
Efficiency
Loss (%) Ext.
Standard Gas 50 gal.
Small Gas
Recirc/Time+Temp
1_ 40,000 50
0.58
n/a n/a
Standard Gas 75 gal.
Small Gas
Recirc/Time+Temp
1 40.000 75
0.58
n/a n/a
Standard Gas 50 gal.
Small Gas
Recirc/fime+Temp
1 40.000 50
0.58
n/a n/a
•
For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
Run Initiation Time: 01115/0408:12:10 Run Code: 1074183130
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 16 of 53
Computer Method Summary
Length
(Part 3 of 3) C -2R
Insulation
R -Val. Depth
Location / Comments
Slab Perimeter
Horn Residence
0.76
2Q
0
HVAC -4
1/15/2004
AdilkProiect Title
026
O -Q
0
IiVAG_5
Date
THERMAL MASS FOR HIGH MASS DESIGN
0.76
0.0
0
Area
Thick.
Heat
O26
Inside
Location
Type (so
(in.)
Cap.
Cond. Form 3 Reference
R -Val.
Comments
Concrete Heavyweight 6-6.3
4M
--28_
0 -Ra n/a
—2
± AC_3LS1ab�n-Glade
Tile in Mortar 698
0_75
24
0_67 n/a
0
HVAC -4 / Interior Mass
Concre e Heavyweight— 698
-4-00
--211
0.-M n/a
0
HVAC -4 / Slab on Grade
Concrete, Heavyweight 1.046
4_00
28
0_98 n/a
2
HVAC -4 / Slab on Grade
IiLe_j0A0ttar 1.359
0.75
24
0.67 n/a
0
HVAC -5 / Interior Mass
PERIMETER LOSSES
Type
Length
F2
Factor
Insulation
R -Val. Depth
Location / Comments
Slab Perimeter
86
0.76
2Q
0
HVAC -4
Slab_2ehmeter
—_QQ
026
O -Q
0
IiVAG_5
Slab Perimeter
1
0.76
0.0
0
HVAC -5
Sl.ab-P-edmeter
77_
O26
_O..Q
Q
HVA�6
Slab-P-erimeter
22
0.76
0.0
0
HVAC -6
HVAC SYSTEMS
Heating Equipment
Minimum
Distribution Type
Split Air Conditioner
Type (furnace, heat
Efficiency
and Location Duct Thermostat
Location /
pump, etc.)
(AFUE/HSPF)(ducts/attic,
etc.) R -Value Type
Comments
-C n_tral Furnace
80° AFUE
Ducts in Attic 6.0 Setback
HVAC -6
Central Furnace
80%AFUE
Ducts in Attic 6.0 Setback
HVAC -7
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Cooling Equipment
Type (air conditioner,
heat pump, evap. cooling)
Minimum Duct
Efficiency Location Duct Thermostat
(SEER) (attic, etc,) R -Value Type
Location /
Comments
Split Air Conditioner
15.0 SEE Ducts in Attic 6.0 Setback
HVAC -6
Split Air Conditioner
16.0 SEER Ducts in Attic 6.0 Setback
HVAC -7
WATER HEATING SYSTEMS
Ratedl Tank
Energy Facts 1 Tank Insul.
Water Heater
Water Heater Distribution # in Input Cap.
or Recovery Standby R -Value
System Name
Type Type Syst. (Btu/hr) (gal)
Efficiency Loss (%) Ext.
1 For small gas storage (rated input —
75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters
(rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
0
Computer Method Summary
(Part 3 of 3) C -2R
Horn Residence
Heating Equipment
Minimum
1/15/2004
-Project Title
Type (furnace, heat
Efficiencyy
Date
THERMAL MASS FOR HIGH MASS DESIGN
Thermostat
Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.)
Area
Thick.
Heat
Inside
Location
Type (sf)
(in.)
Cap.
Cond. Form 3 Reference
R -Val.
Comments
Concrete, Heavyweight X35.9
_4_0_0
28.
0_9$ nLa
0
±LVAC.5_L la�oo G.rade
Concrete, Heavyweight 239
4_00
28
0_98 n/a
2
HVAC -5 / Slab on Grade
Tile in _lQrtar 941
0.75
24
0.67 n/a
0
HVAC -6 / Interior Mass
Concrete, Heavyweight 941
4_00
28
0_98 n/a
0
HVAC -6 / Slab on Grade
Caacr_eie Heaxyxve.igli.t 95
4.00
28
0.98 n/a
2
HVAC -6 / Slab on Grade
PERIMETER LOSSES
Location /
heat pump, evap. cooling)
(SEER)
(attic, etc,)
R -Value Type
Comments
F2
Insulation
Type Length
Factor
R -Val.
Depth Location / Comments
Slab Perimeter 60
0.76
0.0
2 HVAC -7
HVAC SYSTEMS
Heating Equipment
Minimum
Distribution Type
Type (furnace, heat
Efficiencyy
and Location
Duct
Thermostat
Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.)
R -Value Type
Comments
Hydronic Piping Pipe
Pipe
Insul.
System Name Length
Diameter
Thick.
Cooling Equipment
Minimum
Duct
Type (air conditioner,
Efficiency
Location
Duct
Thermostat
Location /
heat pump, evap. cooling)
(SEER)
(attic, etc,)
R -Value Type
Comments
WATER HEATING SYSTEMS
Energy Fact! 1 Tank Insul.
Ratedl Tank
Water Heater
Water Heater Distribution
# in
Input Cap.
or Recovery Standby R -Value
System Name
Type
Type
Syst.
(Btu/hr) (gal)
Efficiency Loss (%) Ext.
•
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
Run Initiation Time: 01/15/0408:12:10 Run Code: 1074183130
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:18 of 53
Coinputer Method Summary (Part 3 of 3) C -2R
Horn Residence 1/15/2004
-Project Title Date
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Location
Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments
on rete, Heavyweight —627 00 _28_ _0_98. n/a 2. 1iVAC� /_S1atZo>LGtade
PERIMETER LOSSES
F2 Insulation
Type Length Factor R -Val. Depth Location / Comments
HVAC SYSTEMS
Heating Equipment Minimum Distribution Type
Type (furnace, heat Efficiency and Location
Duct Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.)
R -Value Type Comments
• Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location
Duct Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc,)
R -Value Type Comments
WATER HEATING SYSTEMS
Rated' Tank Energy Facts Tank Insul.
Water Heater Water Heater Distribution
# in Input Cap. or Recovery Standby R -Value
System Name Type Type
Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext.
For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated
Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
Cj
Run Initiation Time: 01/15/0408:12:10 Run Code: 1074183130
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 19 of 53
Computer Method Summary (Addendum) C -2R
Horn Residence 1/15/2004
-Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. I Plan I Field
0
•
The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
The HVAC System "HVAC -2" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -2" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 964 sqft Tile in Mortar Interior Mass, 0.75' thick at First Floor
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 964 sqft Exposed Slab Floor, 4.00" thick at First Floor
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 241 sqft Covered Slab Floor, 4.00" thick at First Floor
The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
The HVAC System "HVAC -3" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -3" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 165 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -3
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 165 sqft Exposed Slab Floor, 4.00" thick at HVAC -3
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. I Plan I Field
The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC -2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC -3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC -3" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC -4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC -4" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC -5" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:20 of 53 1
Computer Method Summary (Addendum) C -2R
Horn Residence 1/15/2004
-Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. I Plan I Field
•
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 663 sqft Covered Slab Floor, 4.00" thick at HVAC -3
The HVAC System "HVAC -4" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
The HVAC System "HVAC -4" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -4" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -4" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 698 sqft Tile in Mortar Interior Mass, 0.75" thick at HVAC -4
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 698 sqft Exposed Slab Floor, 4.00" thick at HVAC -4
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1046 sqft Covered Slab Floor, 4.00" thick at HVAC -4
The HVAC System "HVAC -5" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
The HVAC System "HVAC -5" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -5" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -5" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1359 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -5
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. I Plan I Field
The HVAC System "HVAC -5" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC -6" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC -6" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC -7" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC -7" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
Run Initiation Time: 01/15/0408:12:10 Run Code: 1074183130
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:21 of 53
Computer Method Summary (Addendum) C -2R
Horn Residence 1/15/2004
-Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. I Plan I Field
•
HIGH MASS Design(see C -21R) - Verify Thermal Mass: 1359 sqft Exposed Slab Floor, 4.00" thick at HVAC -5
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 239 sqft Covered Slab Floor, 4.00" thick at HVAC -5
The HVAC System "HVAC -6" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
The HVAC System "HVAC -6" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -6" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -6" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 941 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -6
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 941 sqft Exposed Slab Floor, 4.00" thick at HVAC -6
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 95 sqft Covered Slab Floor, 4.00" thick at HVAC -6
The HVAC System "HVAC -7" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
The HVAC System "HVAC -7" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -7" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "HVAC -7" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field
Run Initiation Time: 01/15/0408:12:10 Run Code: 1074183130
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:22 of 53
Catnputer Method Summary (Addendum) C-2R
Horn Residence 1/15/2004
AftProject Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
)asea on the aaequacy or the speciai fustirication ana aocumentation supmittea. Plan Field
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 627 sgft Covered Slab Floor, 4.00" thick at HVAC -7
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field
•
•
MWM
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 23 of 53 1
•
PROPOSED CONSTRUCTION ASSEMBLY ENV -3
NAME
Horn Residence
DATE
1/15/2004
COMPONENT DESCRIPTION
DESCRIPTION
WOOD
FRAME
R -VALUE
OUTSIDE SURFACE AIR FILM
1
2
Stucco
Membrane, Vapor -Permeable Felt
3
Plywood
4
Insulation, Mineral Fiber, Loose Fill
5
Gypsum or Plaster Board
6
ASSEMBLY NAME
R-23 Certint blown in Wall
0.31
8
0.37
9
2.60
ASSEMBLY
Floor
0.6801
0.680
23.01
TYPE
(check one)
X Wall
0
LLI
Ceiling I Roof
F
Q
in
FRAMING MATERIAL
Wood
p
Z
FRAMING %
15 %
Framing
15% (16" o.c. Wall)
12% (24" o.c. Wall)
10% (16" o.c. Floor/Cell.)
SKETCH OF ASSEMBLY
7% (24" o.c. Floor/Ceil.)
SUBTOTAI
R -VALUE
DESCRIPTION
WOOD
FRAME
R -VALUE
OUTSIDE SURFACE AIR FILM
1
2
Stucco
Membrane, Vapor -Permeable Felt
3
Plywood
4
Insulation, Mineral Fiber, Loose Fill
5
Gypsum or Plaster Board
6
0.5621
7
0.31
8
0.37
9
2.60
0.26
INSIDE SURFACE AIR FILM
SUBTOTAI
R -VALUE
CAVITY
R -VALUE
(Rc)
WOOD
FRAME
R -VALUE
0.170
0.170
0.1751
0.175
0.060
0.060
0.465
0.465
20.900
5.445
0.5621
0.562
0.31
2.63
0.37
0.98
2.60
0.26
0.68
0.6801
0.680
23.01
7.56
RG RT
'HEAT CAPACITY (Optional)
WALL
WEIGHT
(lbs/sf)
SPECIFIC
HEAT
(Btu/F-Ib)
HC
(A X B)
(Btu/F-sf)
[ 0.0435
X 0.85 ]
8.46
0.20
1.69
0.06
0.35
0.02
1.06
0.29
0.31
2.63
0.37
0.98
2.60
0.26
0.68
14.8
TOTAL HC
3 7
'NOTE: Weight and Specific Heat values for materials
penetrated by wood framing
include the effects of the framing
members.
[ 0.0435
X 0.85 ]
+
[ 0.1323
X L 0.15
1 / Rc
1 - (Fr% / 100)
1 / Rf
Fr% / 100
ASSEMBLY U -VALUE
I EnergvPro 3.1 By EnergvSoft User Number: 3665 Job Number: 0004.00 Page:24 of 53 1
•
PROPOSED CONSTRUCTION ASSEMBLY ENV -3
PROJECT NAME
Horn Residence
DATE
1/15/2004
COMPONENT DESCRIPTION
DESCRIPTION
WOOD
FRAME
R -VALUE
OUTSIDE SURFACE AIR FILM
1
Gypsum or Plaster Board
2
Insulation, Mineral Fiber, Loose Fill
3
Gypsum or Plaster Board
4
0.37
5
ASSEMBLY NAME
R-23 Certin blown in Wall
-2
7
1 - (Fr% / 100)
8
Fr% / 100
ASSEMBLY
Floor
INSIDE SURFACE AIR FILM
0.680
23.60
TYPE
(check one)
X Wall
a
0
/Roof
H
Ceiling
FRAMING MATERIAL
yyo�
p
N
Z
FRAMING %
15 %
Framing
15% (16" o.c. Wall)
12% (24" o.c. Wall)
10% (16" o.c. Floor/Ceil.)
SKETCH OF ASSEMBLY
7% (24" o.c. Floor/Ceil.)
THICK-
NESS
(in.)
0-3-75-
5.750
.3755.750
0.625
SUBTOTAL
R -VALUE
DESCRIPTION
WOOD
FRAME
R -VALUE
OUTSIDE SURFACE AIR FILM
1
Gypsum or Plaster Board
2
Insulation, Mineral Fiber, Loose Fill
3
Gypsum or Plaster Board
4
0.37
5
2.60
6
0.68
7
1 - (Fr% / 100)
8
Fr% / 100
9
INSIDE SURFACE AIR FILM
THICK-
NESS
(in.)
0-3-75-
5.750
.3755.750
0.625
SUBTOTAL
R -VALUE
CAVITY
R -VALUE
(Rc)
WOOD
FRAME
R -VALUE
0.170
0.170
0.3371
0.337
21.850
5.693
0.562
0.562
0.37
1.02
2.60
0.26
0.68
1 / Rc
1 - (Fr% / 100)
1 / Rf
Fr% / 100
ASSEMBLY U -VALUE
0.6801
0.680
23.60
7.44
KC KT
*HEAT CAPACITY (Optional)
WALL
WEIGHT
(lbs/sf)
SPECIFIC
HEAT
(Btu/F-Ib)
HC
(A X B)
(Btu/F-sf)
1.56
0.26
0.41
2.751
0.37
1.02
2.60
0.26
0.68
1 / Rc
1 - (Fr% / 100)
1 / Rf
Fr% / 100
ASSEMBLY U -VALUE
6 9
TOTAL HC
2 1
NOTE: Weight and Specific Heat values for materials
penetrated by wood framing
include the effects of the framing
members.
I0.0424
X 0.85 ]
+
[ 0.1344
XL 0.15 ]
1 / Rc
1 - (Fr% / 100)
1 / Rf
Fr% / 100
ASSEMBLY U -VALUE
I EnergvPro 3.1 By EnerovSoft User Number: 3665 Job Number. 0004.00 Page:25 of 53 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME
Horn Residence
SYSTEM NAME
I HVAC -2
Number of Systems
1
Heating System
Output per System
90,000
Total Output (Btuh)
90,000
Output (Btuh/sqft)
62.3
Cooling System
Output per System
60,000
Total Output (Btuh)
60,000
Total Output (Tons)
5.0
Total Output (Btuh/sqft)
41.6
Total Output (sgft/Ton)
288,8
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sqft)
1.39
Airflow (cfm/Ton)
400.0
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
DATE
1/15/2004
FLOOR AREA
1.444
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
Sensible
1,414
25,947
7,90
667
25,196
0
1,297
1,260
0
0
0
0
0
0
0
0
0
1,297
1,260
28 542 7 90 27 716
HSX19-060/G60UHV-60C-110X (5) 40,574 9,581 90,000
Total Adjusted System Output40,574 9,581 90,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
((-(EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) I
24.0 of 69.4 of 105.0 of 105.0 of
O Supply Air Ducts
Outside Air
0 cfm Heating Coil Supply Fan 104.4 of
2000 cfm ROOMS
70.0 OF
69.4 of
K Return Air Ducts `S
(COOLING SYSTEM PSYCHROMETRICS (Airstream Temoeratures at Time of Coolina Peak) I
114.1 / 80.3 of
Outside Air
0 cfm
72.6/61.9 of
72.6/61.9 OF . 55.0/54.0 OF
Cooling Coil Supply Fa
2000 cfm
55.0 / 54.0 of
Supply Air Ducts
Fan
55.6/54 . 2 of
56.0% R.H. ROOMS
72.0 / 61.7 of
>% Return Air Ducts `i
EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: 0004.00 Page 26 of 53
1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Horn Residence 1/15/2004
SYSTEM NAME FLOOR AREA
HVAC -3 828
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
90,000
Total Output (Btuh)
90,000
Output (Btuh/sgft)
108.7
Cooling System
Output per System
60,000
Total Output (Btuh)
60,000
Total Output (Tons)
5.0
Total Output (Btuh/sqft)
72.5
Total Output (sgft/Ton)
165.6
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sqft)
2.42
Airflow (cfm/Ton)
400.0
Outside Air (%)
0.0
Outside Air (cfm/sqft)
0.00
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK 11COILHTG.PEAK
CFM I Sensib I CFM I Sensible
2,196
40,302
6,782
717
27,088
0
2,015
1,354
0
0
0
0
0
0
0
0
0
2,015
11354
44 332 6,782 29 797
HSX19-060/G60UHV-60C-110X (5) 41,435 8,639 90,000
Total Adjusted System Output 41,435 8,639 90,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
Note: values above given at ARI conditions IL-
JEATING SYSTEM PSYCHROMETRICS (Airstream Tel
24.0 of 69.4 of . 105.0 of
Outside Air
0 cfm
Heating Coil
69.4 OF
Supply Fan
2000 cfm
105.0 of
—� Supply Air Ducts
104.4 of
ROOMS
70.0 of
K Return Air Ducts `{
(COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I
114.1 / 80.3 of
Outside Air
0 cfm
72.9/61.8 of
ec
72.9/61.8OF. 55.0/53.9OF
Cooling Coil
Supply Fa
2000 cfm
55.0 / 53.9 of
Supply Air Ducts
Fan
�% Return Air Ducts 4
55.9/54 . 3 of
55.2% R.H. ROOMS
72.0 / 61.5 of
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page. 27 of 53
WAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE .
Horn Residence 1/15/2004
•SYSTEM NAME FLOOR AREA
HVAC -4 1,744
Number of Systems
1
Heating System
Output per System
90,000
Total Output (Btuh)
90,000
Output (Btuh/sqft)
51.6
Cooling System
Output per System
60,000
Total Output (Btuh)
60,000
Total Output (Tons)
5.0
Total Output (Btuh/sqft)
34.4
Total Output (sgft/Ton)
348.8
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sgft)
1.15
Airflow (cfm/Ton)
400.0
Outside Air (%)
0.0
Outside Air (cfm/sgft) —r--0.00
Note: values above aiven at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
Sensible
1,746
32,039
1 0,527
760
28,710
0
1,602
1,435
0
0
0
0
0
0
0
0
0
1,602
1,435
35,243 10,527 31,581
HSX19-060/G60UHV-60C-110X (5) 39,786 10,770 90,000
Total Adjusted System Output 39,786 10,770 90,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
'ING SYSTEM PSYCHROMETRICS (Airstream Tem
24.0 of 69.3 of . 105.0 of
Outside Air
0 cfm
69.3 of
14.1 / 80.3 of
Outside Air
0 cfm
72.7/62.4 0 F
Heating Coil
at Time of
Supply Fan
2000 cfm
105.0 of
Supply Air Ducts
104.3 of
ROOMS
70.0 of
�% Return Air Ducts `{
72.7 / 62.4 of . 55.0 / 54.0 of
Cooling Coil
Supply Fa
2000 cfm
55.0 / 54.0 of
Supply Air Ducts
Fan 55.7/54.3OF
57.7% R.H. ROOMS
72.0 / 62.1 of
01
Return Air Ducts
I Ener4vPro 3.1 By EnerovSoft User Number: 3665 Job Number: 0004.00 Paae:28 of 53 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Horn Residence 1/15/2004
•SYSTEM NAME FLOOR AREA
HVAC -5 1,598
ENGINEERING CHECKS 11SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
90,000
Total Output (Btuh)
90,000
Output (Btuh/sgft)
56.3
Cooling System
Output per System
60,000
Total Output (Btuh)
60,000
Total Output (Tons)
5.0
Total Output (Btuh/sgft)
37.5
Total Output (sgftrron)
319.6
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sgft)
1.25
Airflow (cfmrron)
400.0
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
EATING SYSTEM PSYCHROMETRICS
24.0 of 69.3 of
I J
Outside Air
0 cfm
69.3 of
114.1 / 80.3 of
Outside Air
0 cfm
72.8/62.4 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensible
Latent
CFM
I Sensible
1,974
36,220
10,687
818
30,909
0
1,811
1,545
0
0
0
0
0
0
0
0
0
1,811
1,545
39,842 10 687
HSX19-060/G60UHV-60C-110X (5) 39,857 10,744
Total Adjusted System Output 39,857 10,744
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK I Aug 2 pm
yam Tem
105.0 of
Heating Coil
Time of H
-�@J
Supply Fan
2000 cfm
90,000
90,000
Jan 12 am
105.0 OF
Supply Air Ducts
104.3 of
ROOMS
70.0 of
k Return Air Ducts 4
72.8 / 62.4 OF . 55.0 / 54.0 of
Cooling Coil
Supply Fa
2000 cfm
55.0 / 54.0 of
Supply Air Ducts
Fan
55.8 / 54.4 of
57.8% R.H. ROOMS
72.0 / 62.2 of
h Return Air Ducts "I
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. 0004.00 Page: 29 of 53
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Horn Residence 1/15/2004
is SYSTEM NAME FLOOR AREA
HVAC -6 1,036
Number of Systems
1
Heating System
Output per System
90,000
Total Output (Btuh)
90,000
Output (Btuh/sgft)
86.9
Cooling System
Output per System
60,000
Total Output (Btuh)
60,000
Total Output (Tons)
5.0
Total Output (Btuh/sgft)
57.9
Total Output (sgft/ron)
207.2
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sgft)
1.93
Airflow (cfm/Ton)
400.0
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensiblel
Latent
I I CFM
I Sensible
1,508
27,671
5,787
570
21,553
0
1,384
1,078
0
0
0
0
0
0
0
0
0
1,384
1,078
30,438 5 787
HSX19-060/G60UHV-60C-110X (5) 41,421 8,447
Total Adjusted System Output 41,421 8,447
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK I Aug 2 pm
EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatina Peak)
24.0 of
Outside Air
0 cfm
69.5 of
114.1 / 80.3 of
Outside Air
0 cfm
72.6/61.5 of
69.5 of E 105.0 of
Heating Coil
90,000
90,000
Jan 12 am
105.0 of
O Supply Air Ducts
Supply Fan 104.5 of
2000 cfm ROOMS
70.0 of
Return Air Ducts I
72.6/61.5OF 55.0/53.9OF
0
Cooling Coil Supply Fa
2000 cfm
55.0 / 53.9 of
Supply Air Ducts
Fan
K Return Air Ducts 11
55.6/54 . 2 of
54.5% R.H. ROOMS
72.0 / 61.3 of
EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: 0004.00 Page:30 of 53
1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Horn Residence 1/15/2004
SYSTEM NAME FLOOR AREA
HVAC -7 627
Number of Systems
1
Heating System
Output per System
54,000
Total Output (Btuh)
54,000
Output (Btuh/sqft)
86.1
Cooling System
Output per System
35,600
Total Output (Btuh)
35,600
Total Output (Tons)
3.0
Total Output (Btuh/sqft)
56.8
Total Output (sgft/Ton)
211.3
Air System
CFM per System
1,200
Airflow (cfm)
1,200
Airflow (cfm/sqft)
1.91
Airflow (cfmfron)
404.5
Outside Air (%)
0.0
Outside Air (cfm/sqft)
0.00
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
1COILHTG.PEAK
CFM
ISensibleF
Latent
1CFM1
Sensible
643
11,801
3,879 330
12,485
0
590
624
0
0
0
0
0
0
0
0
0
590
1 624
12,98 3,879 13 734
HSX19-036/G60UHV-36A-070X (3) 24,181 5,438 54,000
Total Adjusted System Output24,181 5,438 54,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
1EATING SYSTEM PSYCHROMETRICS (Airstream Tel
24.0 OF 69.5 OF . 105.0 OF
Outside Air
0 cfm
69.5 of
114.1/80.30F
Outside Air
0 cfm
72.5/61.6 of
Heating Coil
lei
Supply Fan
1200 cfm
105.0 of
Supply Air Ducts
104.5 of
ROOMS
70.0 of
K Return Air Ducts 4
72.5 / 61.6 of 55.0 / 54.0 of
Cooling Coil
Supply Fa
1200 cfm
55.0 / 54.0 of
Supply Air Ducts
Fan
55.5/54.2OF
55.0% R.H. ROOMS
72.0 / 61.4 of
�, Return Air Ducts '�
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page :31 of 53
•
ROOM LOAD SUMMARY
PROJECT NAME
Horn Residence
DATE
1/15/2004
SYSTEM NAME
HVAC -2
FLOOR AREA
1,444
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
HVAC -2
First Floor
1
1,155
21,204
6,851
1,155
21,204
6,851
566
21,379
HVAC -2
Second Floor (Tower)
1
19
343
159
19
343
159
7
280
HVAC -2
Third Floor (Tower)
1
240 1
4,400
891
240 1
4,400
8911
94 1
3.538
PAGE TOTAL 1 1,414 25,947 7,901 667 25,196
TOTAL 1 1,414 25,947 7,901 667 25,196
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:32 of 53
E
E
ROOM LOAD SUMMARY ::1
PROJECT NAME
Horn Residence
DATE
1/15/2004
SYSTEM NAME
HVAC -3
FLOOR AREA
828
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
HVAC -3
HVAC -3
1
2,196
40,302
6,782
2,196
40,302
6,782
717
27,088
PAGE TOTAL 1 2,196 40,302 6,782 717 27,088
TOTAL 1 2,196 40,302 6,782 717 27,088
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 33 of 53
48
•
ROOM LOAD SUMMARY :1
PROJECT NAME
Horn Residence
DATE
1/15/2004
SYSTEM NAME
HVAC -4
FLOOR AREA
1,744
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
HVAC -4
HVAC -4
1
1,746
32,039
10,527
1,746
32,039
10,527
760
28,710
i
r
PAGE TOTAL 1 1,746 32,039 10,527 760 28,710
TOTAL 1 1,746 32,039 10,527 760 28,710
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 34 of 53
0
L-1
ROOM LOAD SUMMARY
PROJECT NAME
Horn Residence
DATE
1/15/2004
SYSTEM NAME
HVAC -5
FLOOR AREA
1,598
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
HVAC -5
HVAC -5
1
1,974
36,220
10,687
1,974
36,220
10,687
818
30,909
PAGE TOTAL 1 1,974 36,220 10,687 818 30,909
TOTAL 1 1,974 36,220 10,687 818 30,909
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 35 of 53
a
17,
GO
ROOM LOAD SUMMARY
PROJECT NAME
Horn Residence
DATE
1/15/2004
SYSTEM NAME
HVAC -6
FLOOR AREA
1,036
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
HVAC -6
HVAC -6
1
1,508
27,671
5,787
1,508
27,671
5,787
570
21,553
PAGE TOTAL 1 1,508 27,671 5,787 570 21,553
TOTAL 1 1,508 27,671 5,787 570 21,553
EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. 0004.00 Page:36 of 53
1.1
0
ROOM LOAD SUMMARY
PROJECT NAME
Horn Residence
DATE
1/15/2004
SYSTEM NAME
HVAC -7
FLOOR AREA
627
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
HVAC -7
HVAC -7
1
643
11,801
3,879
643
11,801
3,879
330
12,485
PAGE TOTAL 1 643 11,801 3,879 330 12,485
TOTAL 1 643 11,801 3,879 330 12,485
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 37 of 53
Ak
•
ROOM HEATING PEAK LOADS
Project Title Date
Horn Residence 1/15/2004
Room Information Desicin Conditions
Room Name First Floor Time of Peak Jan 12 am
Floor Area 1,205 Outdoor Dry Bulb Temperature 24OF
Indoor Dry Bulb Temperature 70 OF
Conduction Area U -Value AT of Btu/hr
values
38.0
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0341
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
0
1,167.0
0.0275
46.0
1,474
593.5
0.0568
46.0
1,550
106.5
0.4400
46.0
2,156
48.0
0.3872
46.0
855
346.0
0.0644
46.0
1,025
perimeter = 95.5
45.5
4,345
items snown wan an astensK (-rr) denote conduction tnrougn an interior surrace to anotner room. Page Total: 11,406
Infiltration: I 1.00 x 1.080 x 1 205 x 10.00 x 6] x 46 = 9 973
—Schedule Air Sensible Area Ceiling Height ACH OT
Fraction
• TOTAL HOURLY HEAT LOSS FOR ROOM 21,379
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 38 of 53
AK
w
ROOM HEATING PEAK LOADS
Project Title Date
Horn Residence 11/15/2004
Room Information Desicin Conditions
Room Name Second Floor (Tower) Time of Peak Jan 12 am
Floor Area 38 Outdoor Dry Bulb Temperature 24OF
Indoor Dry Bulb Temperature 70 OF
Conduction Area U -Value AT of Btu/hr
38.0
X
x
x
X
X
x
x
x
x
X
x
x
X
x
x
X
X
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0341
X
X
x
x
X
x
X
x
X
x
x
X
x
x
x
x
X
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
0
38.0
0.0341
46.0
60
items shown With an astenSK (`j denote conduction through an interior surface to another room.
rr Page Total: 1 so
Infiltration: II 1.001X 1.080 x 38 x 7.00 x 1.00 / 60] x 46 = 220
chedule Air Sensible Area Ceiling Height ACH OT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 39 of 53
280
AK
w
ROOM HEATING PEAK LOADS
Project Title Date
Horn Residence 1/15/2004
Room Information Desicin Conditions
Room Name Third Floor (Tower) Time of Peak Jan 12 am
Floor Area 201 Outdoor Dry Bulb Temperature 24 OF
Indoor Dry Bulb Temperature 70 OF
Conduction Area U -Value AT of Btu/hr
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total
Infiltration: L 1.001 x 1.080 x 201 x 7.50 x 6] x 46
Schedule Air Sensible Area Ceiling Height ACH OT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM
254
870
850
316
2 290
= 1248
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 40 of 53
201.0
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0275
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
46.0
333.2
0.0568
46.0
42.0
0.4400
46.0
201.0
0.0341
46.0
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total
Infiltration: L 1.001 x 1.080 x 201 x 7.50 x 6] x 46
Schedule Air Sensible Area Ceiling Height ACH OT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM
254
870
850
316
2 290
= 1248
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 40 of 53
9
ROOM HEATING PEAK LOADS
Project Title Date
Horn Residence 1/15/2004
Room Information Desion Conditions
Room Name ' HVAC -3 Time of Peak Jan 12 am
Floor Area 828 Outdoor Dry Bulb Temperature 24OF
Indoor Dry Bulb Temperature 70°F
Conduction Area U -Value AT of Btu/hr
Assumed
828.0
392.0
602.4
41.6
perimeter = 74.0
0.0275
0.0568
0.3800
0.4400
Items shown with an asterisk ('r) denote conduction through an interior surface to another room.
Infiltration: 1.001X 1.080 x 828 x 15.00 x 1.00 / 60] x
chedule Air Sensible Area Ceiling Height ACH
Fraction
46.0
46.0
46.0
46.0
45.5
1,046
1,024
10,530
842
3,367
Page Total: I 16,8091
46 = 10 280
DT
TOTAL HOURLY HEAT LOSS FOR ROOM 27
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:41 of 53
•
ROOM HEATING PEAK LOADS
Project Title Date
Horn Residence 1/15/2004
Room Information Design Conditions
Room Name HVAC -4 Time of Peak Jan 12 am
Floor Area 1,744 Outdoor Dry Bulb Temperature 24°F
Indoor Dry Bulb Temperature 70 OF
Conduction Area U -Value AT of Btu/hr
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 13 265
Infiltration: 1 1.00 x 1.080 x 1 744 x 10.70 x 6] x 46 = 15445
chedule Air Sensible Area Ceiling Height ACH OT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 28.710
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. 0004.00 Page: 42 of 53
1,744.0
x
x
X
x
X
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0275
x
X
X
X
X
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
46.0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
2,203
334.0
0.0644
46.0
990
409.3
0.0568
46.0
1,069
160.0
0.3800
46.0
2,797
89.7
0.4400
46.0
1,816
perimeter = 96.5
45.5
4,391
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 13 265
Infiltration: 1 1.00 x 1.080 x 1 744 x 10.70 x 6] x 46 = 15445
chedule Air Sensible Area Ceiling Height ACH OT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 28.710
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. 0004.00 Page: 42 of 53
ROOM HEATING PEAK LOADS
1
Project Title Date
Horn Residence 1/15/2004
Room Information Des! - n Conditions
Room Name HVAC -5 Time of Peak Jan 12 am
Floor Area 1,598 Outdoor Dry Bulb Temperature 24 of
Indoor Dry Bulb Temperature 70°F
Conduction Area U -Value AT of Btu/hr
A
1,598.0
x
x
X
x
x
X
X
x
X
x
x
X
x
x
X
X
x
x
X
X
x
X
X
x
x
x
x
X
X
X
X
X
X
X
X
X
X
Xx
X
0.0275
X
x
x
x
x
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
x
X
X
x
X
X
X
X
x
X
X
x
X
x
X
X
x
X
46.0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
2,018
1,112.2
0.0568
46.0
2,905
253.0
0.3800
46.0
4,422
32.8
0.4400
46.0
664
perimeter = 110.5
45.5
5,028
P
Items shown with an asterisk (•rr) denote conduction through an interior surface to another room. Page Total: 15 038
Infiltration: I1.00 x 1.080 x 1 598 x 12.00 x 1.00 / 60] x 46 = 15 871
chedule Air Sensible Area Ceiling Height ACH OT
Fraction
TOTAL HOURLY HEAT
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 43 of 53
•
ROOM HEATING PEAK LOADS
Project Title Date
Horn Residence 11/15/2004
Room Information Desi - n Conditions
Room Name HVAC -6 Time of Peak Jan 12 am
Floor Area 1,036 Outdoor Dry Bulb Temperature 24 of
Indoor Dry Bulb Temperature 70°F
Conduction Area U -Value AT of Btu/hr
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 13 150
Infiltration: I rrx 1.080 x 1 036 x 9.80 x 6] x 46 = 8 403
chedule Air Sensible Area Ceiling Height ACH OT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 21.553
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 44 of 53
1036.0
X
x
X
x
X
x
X
x
X
X
x
X
X
X
x
x
X
X
x
x
X
X
X
X
X
x
X
X
X
X
x
x
x
X
X
X
X
X
x
0.0275
x
X
x
x
x
X
x
x
X
X
X
X
x
X
X
x
X
x
X
x
x
X
x
X
X
X
X
x
x
x
x
x
x
X
X
x
X
x
x
46.0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1,309
765.0
0.0568
46.0
1,998
32.0
0.0644
46.0
95
300.0
0.3800
46.0
5,244
perimeter = 99.0
45.5
4,504
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 13 150
Infiltration: I rrx 1.080 x 1 036 x 9.80 x 6] x 46 = 8 403
chedule Air Sensible Area Ceiling Height ACH OT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 21.553
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 44 of 53
ROOM HEATING PEAK LOADS
Project Title Date
Horn Residence 1/15/2004
Room Information Desicin Conditions
Room Name HVAC -7 Time of Peak Jan 12 am
Floor Area 627 Outdoor Dry Bulb Temperature 24 OF
Indoor Dry Bulb Temperature 70 OF
Conduction Area U -Value AT of Btu/hr
Wood Door
627.0
x
x
x
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0275
x
x
X
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
46.0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
792
599.7
0.0568
46.0
1,566
62.3
0.4400
46.0
1,261
24.0
0.3872
46.0
427
perimeter = 60.0
45.5
2.730
Items shown with an asterisk (`r) denote conduction through an interior surface to another room. Page Total: 6 777
Infiltration: 1.00 x 1.080 x 627 x 11.00 x 6] x 46 = 5 708
hedule Air Sensible Area Ceiling Height ACH AT
Fraction
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 45 of 53
•
0
fZESIDENTIAL ROOM COOLING LOAD SUMMARY
Horn Residence 1/15/2004
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Conduction
Area
167
106.
U -Value
X
0.034'
X
0.0275
X
0.0568
X
0.4400
X
0.3872
X
0.0644
X
41.6
x
174
X
1
First Floor
72°F
115°F
430F
X
X
X
X
X
X
DETD 1
=
=
=
=
=
=
Btu/hr
0.0
0
62.0
1,987
41.6
1,402
43.0
2,015
41.6
773
41.6
927
X
X
X
1. Design Equivalent Temperature Difference (DETD) Page Total 7 104
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
CsmntWdw (E2)
(North)
FxdG1s1N_dmL(.F_4.)
CsmntWdw E1
(Northeast)
CsmntWdw F1
_(Northeast)
(Northeast)
CsmntWdw (F2)
(Northeast)
CsmntWdw F3
(Northeast)
CsmntWdw E3
(East)
CsmntWdw D
(East)
48)
0.289
174
( 0.0
( 0.0
x1
X
x
x
X
X
x
x
x
x
+
+
+
+
+
+
+
+
+
+
3.0
x
x
x
X
X
X
x
x
X
x
15)
X
x
x
x
X
)x
)x
0.289
=
=
=
=
=
=
=
=
=
=
13
( 0.0
1
12.5
48)
0.289
174
( 0.0
1
3.0
48)X
0.289
42
( 0.0
1
7.5
48)
0.289
104
( 0.0
1
25.0
48)
0.289
347
( 0.0
1
7.5
48)
0.289
104
( 0.0
1
3.0
73)X
0.289
63
( 0.0
1
45.0
73)X
0.289
951
(
(
Sched.
Page Total 1 7ss
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 1,205 x 0.500 Watts/sqft x 3.41 BtuhlWatt = 2,056
Occupants 1.00 X 1,205 X 255 Btuh/occ. / 333 sgft/occ. = 923
Receptacle 1.00 x 1,205 x 0.000 Watts/sqft x 3.413 BtuhlWatt = 0
Process 1.00 x 1,205 x 0.000 18 Watts�/sgftx 3.413 Btuhh[VVatt = 0
Infiltration: �C��
x 1=17y8 x 205 x 0_QO x [ 1.0t01 / 60] �43J =9_32.3
Schedule Air Sensible Area Ceiling Height ACH LST
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,204
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 1 205 x 225 Btuh/occ. / 333 sgft/occ. = 814
Receptacle 1.00 X 1 205 x 0.000 Watts/sgft X 3.41 BtuhfWatt = 0
Process 1.00 X 1 205 x 0.000 Wafts/sqft X 3.41 Btuh/Waft = o
Infiltration: 1.00x 4 840 x 1 205 x 10.00 x 1.00 / 60] 0.00621 = 6 037
chedule Alr Latent Area Ceiling Height ACH Z -\W
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,851
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 46 of 53
,RESIDENTIAL ROOM COOLING LOAD SUMMARY
Horn Residence 1/15/2004
Project Tide Date
•
Room Name Second Floor (Tower)
is
•
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
72°F
115°F
43°F
Conduction Area U -Value DETD 1 Btu/hr
X 0.0 = 0
X 33.0 = 43
X =
X =
X =
X =
X =
X =
X =
1. Design Equivalent Temperature Difference (DETD)
Page Total 43
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded
Unshaded
Solar Gain Orientation Area SGF
Area SGF
SC Btu/hr
(
x
+
x
)x
=
(
x
+
x
)x
=
(
x
+
x
)x
=
(
x
+
x
)x
=
(
x
+
x
)x
=
(
x
+
x
)x
=
(
x
+
x
)x
=
(
x
+
x
)x
=
(
x
+
x
)x
=
Sched. Page Total 0
Internal Gain Frac. Area Heat Gain Btu/hr
Li hts 1.00 x 38 x 0.500 Watts/sgft x 3.412 Btuh/Waft = 65
Occupants 1.00 x 38 x 255 Btuh/occ. / 333 sgft/occ. = 29
Receptacle 1.00 x 38 x 0.000 Watts/sgft x 3.413 BtuhlWatt = 0
Process 1.00 x 38 x 0.000 Wafts/sgft x 3.412 Btuh/Waft = o
Infiltration: E1.00 x1.oso x x oD x =11J / 60] =3 = Q6
Schedule Air Sensible Area Ceiling Height ACH nT
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 343
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 38 x 225 Btuh/occ. / 333 sgft/occ. = 26
Receptacle 1.00 x 38 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = 0
Process I� 1.00 x 38 x 0.000 Wafts/sqft x 3.41 Btuh/Waft = o
Infiltration:I 1.00 x 4 840 x �3 x 7.00 x 1.00 / 60] 0.00621 = 133
"`Schedule Air Latent Area Ceiling Height ACH Z -\W
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 159
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 47 of 53
E
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Horn Residence 1/15/2004
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Conduction
Area U -Value
201
Third Floor (Tower)
720F
115°F
430E
DETD 1
x 62.0
x 41.6
x 43.0
x 33.0
x
x
x
x
x
Btu/hr
342
787
795
226
1. Design Equivalent Temperature Difference (DETD)
Page Total
2 150
Items shown with an asterisk (') denote conduction through
an interior surface to another room.
Shaded
Unshaded
Solar Gain
Orientation
Area SGF
Area
SGF
SC
Btu/hr
CsmntWdw S4
-(North) (
0.0
x
1
+
10.5
X
15
) X
0.289
=
46
CsmntWdw
(East) (
0.0
x
1
+
10.5
X
73
)x
0.289
=
222
CsmntWdw S2
(South) (
0.0
x
1
+
10.5
x
32)X
0.289
=
97
CsmntWdw S3
_(West) (
0.0
x
1
+
10.5
X
73)x
0.289
=
222
(
x
+
x
)x
=
(
x
+
x
)x
=
(
x
+
x
)x
=
(
x
+
x
)x
=
(
x
+
X
)x
=
Sched. Page Total 587
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 x 201 X 0.500 Watts/sgft x 3.413 Btuh/Waft = 343
Occupants 1.00 X 201 X 255 Btuh/occ. / 333 sqft/occ. = 154
Receptacle 1.00 x 201 X 0.000 Wafts/sqft X 3.413 Btuh/Waft = 0
Process 1.00 x 201 x X�0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Infiltration: OA x 1.080 x x I7-5DJ x1.00 / 60� = 1,166
Schedule Air Sensible Area Ceiling Height ACH OT
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 4,400
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 201 X 225 Btuhlocc. / 333 sqft/occ. = 136
Receptacle 1.00 x 201 x 0.000 Watts/sgft X 3.41 Btuh/Waft = 0
Process 1.00 x 201 x 0.000 Wafts/sqft x 3.a1 Btuh/Waft = o
Infiltration: 1.00 x 4840 x 20 x Height
x 60] 0.00621 = 755
chedule Air Latent Area Ceiling Height ACH DW
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 891
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 48 of 53
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Horn Residence 1/15/2004
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Conduction
Roof
Area U -Value
X
0.
HVAC -3
72°F
115°F
43°F
X
X
X
X
X
X
X
X
X
DETD 1
=
=
=
=
=
_
=
=
-
Btu/hr
62.0
1,410
41.6
926
43.0
9,843
43.0
787
FxdGlsWdw Q4
(Southeast)
FxdGlsWdw Q5
(Southeast)
SIdgGIsDr 51)
(Southeast)
Sld GlsDr 52
Southeast
48)
0.468
1. Design Equivalent Temperature Difference (DETD) Page Total 12 966
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF . SC Btu/hr
FxdGlsWdw (Q1)
(Northeast)
dGtsWdw(
(Northeast)
FxdGlsWdw Q3
(Northeast)
Sld GIsDr (47)
(Northeast)
SIdgGIsDr (48)
(Northeast)
Sid GIsDr 49
(Northeast)
FxdGlsWdw Q4
(Southeast)
FxdGlsWdw Q5
(Southeast)
SIdgGIsDr 51)
(Southeast)
Sld GlsDr 52
Southeast
( 0.0
x
x
x
x
X
X
x
x
X
X
1
+
+
+
+
+
+
+
+
+
+
20.8
X
x
X
X
x
X
x
x
X
x
48
) X
)x
X
x
x
x
x
) x
0.468
=
=
=
=
=
=
=
=
=
=
467
( 0.0
1
20.8
48
0.468
467
( 0.0
1
20.8
48)
0.468
467
( 0.0
1
108.0
48)
0.468
2,424
( 0.0
1
108.0
48)
0.468
2,424
( 0.0
1
108.0
48)X
0.468
2,424
( 0.0
1
20.8
62)X
0.289
373
( 0.0
1
20.8
62)
0.289
373
( 0.0
1
108.0
62)
0.468
3,131
( "I
1
108.0
62
0.468
3,131
Sched.
Page Total 15 s8o
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 x 828 X 0.500 Watts/sgft x 3.41 BtuhNVaft = 1,413
Occupants 1.00 X 828 X 255 Btuh/occ. / 333 sgft/occ. = 634
Receptacle 1.00 x 828 x 0.000 Wafts/sgft X 3.413 Btuh/Waft = 0
Process �1.00�X X828 X X0.00000 Wafts/sqft X 3.41�Btuhh Watt = 0
Infiltration: [ 00 x I 1.0001 x [ 281 x L_1.5 a x / 60] 1�.3J = 9 do
Schedule Air Sensible Area Ceiling Height ACH LST
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 40 302
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 828 X 225 Btuh/occ. / 333 sgft/occ. = 559
Receptacle 1.00 x 828 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = o
Process 1.00 x 828 x 0.000 Wafts/sqft x 3.41 Btuh/Waft = o
Infiltration: 1 1.00 111111 X 4,8401 x 828 X 15.00 X 1.00 / 60] 0.00621 = 6 222
chedule Alr Latent Area Ceiling Height ACH �yy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,782
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 49 of 53
•
0
0
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Horn Residence 1/15/2004
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Conduction
Area U -Value
1.744.4
X
DETD 1
62.0
41.6
41.6
43.0
43.0
HVAC -4
720F
115°F
430E
Btu/hr
-
2,969
895
967
2,614
1.6 7
1. Design Equivalent Temperature Difference (DETD) Page Total 9 143
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
Sid GIsDr 54
(South)
S1dgGhDr (55.)
(South)
CsmntWdw M1
(Southwest)
FxdGlsWdw M2
_(Southwest)
CsmntWdw (M3)
(Southwest)
CsmntWdw N1
(West)
CsmntWdw N2
(West)
32)x
0.468
1,197
( 0.0
1
6.0
( 0.0
X
x
x
x
X
X
x
x
x
x
1
+
+
+
+
+
+
+
+
+
80.0
x
x
x
x
x
x
X
x
x)X
x
32)
X
)x
)x
0.468
=
=
=
=
=
=
=
=
=
1,197
( 0.0
1
80.0
32)x
0.468
1,197
( 0.0
1
6.0
62)x
0.289
108
( 0.0
15
32.5
62)x
0.289
583
( 0.0
1
6.0
62)x
0.289
108
( 0.0
1
25.2
73)X
0.289
532
( 0.0
1
20.0
73)x
0.289
423
(
(
(
Sched.
Page Total 4 147
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 x 1,744 x 0.500 Watts/sgft x 3.412 Btuh/Waft = 2,976
Occupants 1.00 X 1,744 X 255 Btuh/occ. / 333 sgft/occ. = 1,335
Receptacle 1.00 x 1,744 x 0.000 Wafts/sgft X 3.413 Btuh/Watt = 0
Process 1.00 X 1,744 x X�0.000 Wafts/sgft x 3.412 Btuh/Watt = o
Infiltration: �= x x 1,244 x [=- oz xQo / 60] = 1;:;;8
Schedule Air Sensible Area Ceiling Height ACH LST
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 32,039
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occu ants1.00 x 1 744 x 225 Btuh/occ. / 333 sgft/occ. = 1 178
Receptacle 1.00 x 1 744 x 0.000 Watts/sqft x 3.41 Btuh/Waft = o
Process 1.00 X 1 744 x 0.000 Wafts/sgft X 3.41 BtuhMaft = o
Infiltration: �chedulle x Air Latent t0 X Area 744 X Ceiling Height x ACH 00 / 60] -\V0o621 = 9349
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 10,527
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. 0004.00 Page: 50 of 53
0
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Horn Residence 1/15/2004
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
HVAC -5
72°F
115°F
43°F
Conduction Area U -Value DETD 1 Btu/hr
x
x
x
x
x
x
x
x
x
62.0
=
=
=
=
=
=
=
=
=
2,720
41.6
2,627
43.0
4,134
43.0
621
FxdGlsWdw 53c
(Southeast)
1
3.8
48
0.289
53
( 0.0
1
29.0
1. Design Equivalent Temperature Difference (DETD) Page Total 10,1021
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF Sc Btu/hr
Sld GIsDr (Entry)
_(Northeast)
CsmntG
(Northeast)
CsmntWdw H
(Southeast)
Sw GIsDr 53a
(Southeast)
FXdGISWdw (53b)
(Southeast)
FxdGlsWdw 53c
(Southeast)
1
3.8
48
0.289
53
( 0.0
1
29.0
( 0.0
x
X
x
x
x
X
x
x
x
x
1
+
+
+
+
+
+
+
+
+
+
88.0
X
X
X
X
x
x
x
x
x
x
48)X
) x
x
x
x
)x
)x
)x
)x
0.468
=
=
=
=
=
=
=
=
=
=
1,975
( 0.0
1
3.8
48
0.289
53
( 0.0
1
29.0
62)
0.289
520
( 0.0
1
120.0
62)
0.468
3,479
( 0.0
1
22.5
62)
0.468
652
( 0.0
1
22.5
62)X
0.468
652
(
(
(
(
Sched.
Page Total 7 331
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 x 1,598 x 0.500 Watts/sgft x 3.413 Btuh/Watt = 2,727
Occupants 1.00 X 1,598 X 255 Btuh/occ. / 333 sgft/occ. = 1,224
Receptacle 1.00 x 1,598 x 0.000 Watts/sqft x 3.413 Btuh/Waft = 0
Process 1.000xx 1,598 x 0.000 Waftts/sgft Ix 3.413Btuh/Watt = 0
Infiltration: � 1.00 �
x �17m0 x 598 x OD x I 1.OQJ / 60] 1�3J =836
Schedule Air Sensible Area Ceiling Height ACH LST
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 36,22J
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants1.00 x 1 598 x 225 Btuh/OCC. / 333 sgft/occ. = 1 080
Receptacle 1.00 x 1 598 x 0.000 Watts/sgft x 3.41 Btuh/Waft = o
Process 1.00 x 1 598 x 0.000 Watts/sgft x 3.41 Btuh/Watt = o
Infiltration: 1.001 x 4 840 x 1 598 x 12.00 x 1.00 / 60] 0.00621 = 9 607
chedule Alr Latent Area Ceiling Height ACH Qyy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 10,687
EnergyPro 3.1 By EnercySoft User Number: 3665 Job Number: 0004.00 Page: 51 of 53
0
PJ
i
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Horn Residence 1/15/2004
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Conduction
Area U -Value
1 0.02751
HVAC -6
720F
115°F
43°F
X
X
X
X
X
X
X
X
X
DETD 1
=
=
=
=
=
=
=
=
=
Btu/hr
62.0
1,764
41.6
1,807
41.6
86
43.0
4,902
1. Design Equivalent Temperature Difference (DETD) Page Total 8 559
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF Sc Btu/hr
Sld GlsDr 03 Southwest ( 0.0 x 1 + 180.0 X 62) X 0.468 = 5,218
S.wg.GlsDtGO _(Southwest) ( 0.0 x 1 + 120.0 x 62) X 0.468 = 3,479
( x + x )x =
( x + x )x =
( x + x )x =
( x + x )x =
( x + x )x =
( x + x )x =
( X + X I )X =
Sched. Page Total 8 sss
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 1,036 X 0.500 Watts/sqft x 3.412 Btuh/Watt = 1,768
Occupants 1.00 X 1,036 X 255 Btuh/OCC. / 333 sgft/OCc. = 793
Receptacle 1.00 x 1,036 X 0.000 Watts/sgft x 3.413 Btuh/Waft = 0
Process 1.00 x 1,036 x 0.000 Watts/sqft x 3.41 BtuhlWatt = 0
Infiltration: ��_ 00 x X1-36 X x 1.00 / 60]
chedule Air Sensible Area Ceiling Height ACH LST
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 27671
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 1 036 X 2251 Btuh/occ. / 333 sgft/occ. = 700
Receptacle 1.00 x 1 036 X 0.000 Watts/sgft X 3.41 Btuh/Waft = o
Process r 1.00 x 1 036 X 0.000 Watts/sqft x 3.41 Btuh/Waft =
Infiltration: I 1.00 x L 4,8401 x 1 03 x 9.80 x 1.00 / 60] 0.00621 = 5 087
"` chedule Alr Latent Area Ceiling Height ACH Lew
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 5,787
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 62 of 53
Is
\_J
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Horn Residence 1/15/2004
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Conduction
Area U -Value
X
DETD1
62.0
41.6
43.0
41.6
HVAC -7
72DF
115DF
430E
Btu/hr
1,067
1,417
1,179
387
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 4 049
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
CsmntWdw J1
Northwest
FxdGIsVl/rf
(Northwest)
CsmntWdw J3
(Northwest)
CsmntWdw K1
(Northwest)
CsmntWdw (K4)
(Northwest)
CsmntWdw L
(Northwest)
1
22.0
48)
0.289
306
( 0.0
1
11.0
( 0.0
X
x
x
x
X
x
x
x
x
X
1
+
+
+
+
+
+
+
+
+
+
11.0
X
x
x
X
x
x
X
X
x
x
48)X
x
)X
x
)X
)x
)X
)X
0.289
=
=
=
=
=
=
=
=
=
=
153
( 0.0
1
22.0
48)
0.289
306
( 0.0
1
11.0
48
0.289
153
( 0.0
1
6.0
48)x
0.289
83
( 0.0
1
6.0
48)
0.289
83
( 0.0
1
6.3
48)X
0.289
88
(
(
(
(
Sched. Page Total 896
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 x 627 x 0.500 Wafts/sgft x 3.41 BtuhlWaft = 1,070
Occupants 1.00 x 627 x 255 Btuh/occ. / 333 sgft/occ. = 480
Receptacle 1.00 x 627 x 0.000 Wafts/sgft x 3.413 Btuh/Waft = 0
Process ��1.000x�x 627 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = 0
Infiltration: �� x �L D x L 6221 x 11.00 x / 60� = 5 3�6
Schedule Air Sensible Area Ceiling Height ACH z -\T
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,8011
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 627 x 225 Btuh/occ. / 333 sqft/occ. = 424
Receptacle 1.00 x 627 x 0.000 Watts/sgft x 3.41 Btuh/Waft = 0
Process 1.00 x 627 x 0.000 Wafts/sgft x 3.41 BtuhlWaft = 0
Infiltration: 1 1.00 x 4840 X 62 x 11.00 x 1.00 / 60] 1 0.00621 = 3 455
chedule AIr Latent Area Ceiling Height ACH LAW
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,879
EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: 0004.00 Page: 53 of 53
.01/04/2005 09:09 17603401819 PAGE 02/02
.i.v•.•y././.../:/rri✓:i:.:.:r.vv;/./.;ri.:%r/i•rrn.n./.:/r/l/vi.i•/.•py.�•�.�././:I•'n'Ii/.l✓.•%Y:n•nvvii:..•n•ni vn vi•ivivri•nuavarz•/a•i/riv.v.•n.nv/i•iv.'/:r•nn•n/i!:/:..i:: •M
INSULATION CERTIFICATE
This i:. ':o certify that insulation has been Installed in conformanaa with the current energy
regular: on, California Administrative Code, Title 24, State of California, in the building at
s
53-317 VI A LOT 274, @ THE HIDEAWAY, LA QUINTA CA
CEII-I : GS:
TYPE: BLOW MANUFACTURER: Certainteed THICKNESS: R-38
WALL,;:
`. TYPE: BLOW MANUFACTURER: Certainteed TWECKI4ESS: R-22
GENE :;AL CONTRACTOR: STEPHEN JONES CONSTRUCTION LICENSE #
TITLE:
PARA:ON SCHMID BUILDING PRODUCTS A MASCO Company, LICENSE # 221517
BY: TIT>,E: ACCOUNT REPRESENTIVE. DATE: i �/ ✓
��-:�..�..�:�.�r.�s..�.>R.as+arn�arnrs...a,.-....,.....r.�;i•,�n,✓s...ors�r.: �<i.. -.
i
INSULATION CERTIE'ICATE
This R' r certify that insulation has been installed in conformance, with the cum nergy
regulal on, lifornia Administrative Code, Title 24, State of California ja-tKe building located at
CEILII, ,GS:
TYPE; 3LOw MA ACTURER: Corralinteed THICKNESS: R-38
TYPE:: BATTS MA IN6CTURER: John Manville THICKNESS: R-13
GENE :IAL CONTRACTOR: LICENSE # `
BY:_.. ., - TITLE:
PAR,1;60N ;SCHMID BUILDING PRODUCTS A MASCO Corripany LTCFNSE # 221517
BY: TITLE: ACCOUNT REPRESENTIVE [)ATE:
. .. : , ro7i r: .r.•/.•i✓:!/'.��•=.•v.n:•�:Y%.f•.r/`..nirl'✓svr.[^:r.vr/'%n.U,.yNAird%.,!•✓yvfHNNNNis•h'.V.V iiN'i}•HN.d'%r'A'N%YNAiv /r b'n �n.7 it :s:vi e:rr. .v:s .. ii /. i. .. ,. :,-�v
4
Sladden Engineering
6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369
39-725 Garand Ln., Suite G, Palm Desert, CA 92211 (760) 772-3893 Fax (760) 772-3895
August 20, 2003 Project No. 522-3325
03-07-465
Stephen Jones
P.O. Box 4656
Palm Desert, California 92261
Project: Lot 274 -Via Pessaro
The Hideaway
Palm Desert, California 92261
Subject: 'Geotechnical Update
Ref: 1. Report of Testing and Observations During Pad Regrading prepared by Sladden Engineering
dated August 13, 2003, Project No. 544-2199, Report No. 03-04-225.
2. Report of Testing and Observation During Rough Grading prepared by Earth Systems
Southwest (ESS) dated August 28, 2002; File No. 07117-11, Report No. 01-07-718.
3. Geotechnical Engineering Report prepared by Earth Systems Southwest dated April 11, 2001;
File No. 08119-01.
As requested, we have reviewed the above referenced geotechnical reports as they relate to the design and
construction of the custom residence. The project site is located on Lot 274 along Via Pessaro within the
�. Hideaway Golf Club development in the City of La Quinta, California. It is our understanding that the
proposed residence will be a relatively lightweight wood frame structure supported by conventional
shallow spread footings and concrete slabs on grade.
The subject lot was previously graded during the rough grading of the Hideaway project site and was
recently regraded. The rough grading included overexcavation of the native surface soils along with the
placement of engineered fill material to construct the subject building pad and adjacent lots. The recent
regrading included processing the surface soil along with minor cuts and fills to construct the individual
building pads. Some additional overexcavation was performed in areas where the building envelopes were
reconfigured. The approximate building envelope is indicated on the attached site plan. The site grading is
summarized in the referenced Report of Testing and Observation During Rough Grading prepared by ESS
and the recent grading report by our firm.
The referenced reports include recommendations pertaining to the construction of residential structure
foundations. Based upon our review of the referenced reports, it is our opinion that the structural values
included in the above referenced reports remain applicable for the design and construction of the proposed
3 residential structure foundations.
Because the lot has been previously rough graded, the remedial grading required at this time should be
minimal. The building area should be cleared of surface vegetation, scarified and moisture conditioned
prior to precise grading. The exposed surface should be compacted so that a minimum of 90 percent
relative compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at
near optimum.inoisture content and compacted to at least 90 percent relative compaction.
1
August 20, 2003
-2- Project No. 522-3325
03-07-465
Allowable Bearing Pressures: The allowable bearing pressures recommended in the referenced grading
report remain applicable. Conventional shallow spread footings should be bottomed into properly
compacted fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should
be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and
isolated pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 2000 psf,
respectively. Allowable increases of 300 psf for each additional 1 foot of width and 300 psf for each
additional 6 inches of depth may be utilized if desired. The maximum allowable bearing pressure should
be 3000 psf. The recommended allowable foundation bearing pressures may be increased by one-third
when considering wind and seismic loading.
The bearing soils are non -expansive and fall within the "very low" expansion category in accordance with
Uniform Building Code (UBC) classification criteria. Pertinent 1997 UBC Seismic Design parameters are
summarized on the attached data sheet.
If you have questions regarding this letter or the referenced reports, please contact the undersigned.
Respectfully submitted,
SLADDEN ENGINEERING
Brett L. Anderson
Principal Engineer
SER/pc
Copies: 4/Stephen Jones
Sladden Engineering
51
August 20, 2003 -3- Project No. 522-3325
03-07-465
1997 UNIFORM BUILDING CODE INFORMATION
The International Conference of Building Officials 1997 Uniform Building Code contains substantial
revisions and additions to the earthquake engineering section in Chapter 16. Concepts contained in the
code that will likely be relevant to construction of the proposed structures are summarized below.
Ground shaking is expected to be the primary hazard most likely to affect the site, based upon proximity to
significant faults capable of generating large earthquakes. Major fault zones considered to be most likely to
create strong ground shaking at the site are listed.below.
Fault Zone
Approximate Distance
From Site
Fault Type
1997 UBC
San Andreas
9.8 km
A
San Jacinto
26 km
A
Based on our field observations and understanding of local geologic conditions, the soil profile type judged
applicable to this site is So, generally described as stiff or dense soil. The site is located within UBC
Seismic Zone 4. The following table presents additional coefficients and factors relevant to seismic
mitigation for new construction upon adoption of the 1997 code.
Sladden Engineering
Near -Source
Near -Source
Seismic
Seismic
Seismic
Acceleration
Velocity
Coefficient
Coefficient
Source
Factor, N,,
Factor, N,
Ce
C,,
San Andreas
1.01
1.22
0.44 Ne
0.64 N„
San Jacinto
1.0
1.0
0.44 Na
0.64 N„
Sladden Engineering