Loading...
0310-293 (SFD)i LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class- Exp. Date ,51Si]3 13HIC 3 10r)1?12( l/ /Date ' %J� Signature of Contractor!-��� f Ake r / �.a OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code), ( ) I, as owner of the property, am.exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier 13I'AS'.F.FUN I) Policy No. 224.4095-2009 (This. section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code., I`shall forthwith comply with•those provisions.I `/ Date %/ ff Applicant � l9.lr':, i A � ;/ Warning: Failure to secure*Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to�the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby'authorize representatives of this City to enter upon the above-mentioned property/for inspection pugposes.\ ` i'. / / Signature (Owner/Agent)rfr��f*'/{''/Li�?i/ ate 2P4% BUILDING PERMIT PERMIT# f. 0.11 10-2!A-3 DATE VALUATION b 5(nt 90 LOT 27 4 TRACT 29894-2 JOB SITE ADDRESS F3-J�'P.-% VIAS.A. APN 711.5.,52(1-020 OWNER CONTRACTOR/DESIGNER/EN (NEER J�! 1c2:Ct r 1), 1ORM fi M. P.M..W J01*THS l;%1':.aUCRIT & CONKRUC i7ra 49641. AVRADER POST (3F�'.(Vk1:D12A)M1':' 4656 t.Q222x:1 l �ALast���A CA 92,61-4C (760)346.3366 CMI'11 2096 USE OF PERMIT 13555 Sr SF„'J•' DT ryVPt ". IT DOPS MCT INCLUDE POOUaP.A OR , BLOCK WA L . 206 h -C, CUSTOM COMSTRUCTIUN 51555.00 OF POR.Ci-11111 l.TIC, 1,980.00 NF'' 0ARA!:GMARPt3RT 11519.04 SP FST. i9 :.rED OOSM OF {:t?AI M1.JC: IO.P3 724,5W.90 PERAIM FEE N'UA014AaCV CONSTRUCTION FEE 101.000.418.000 $21114.50 PLAN CHECK FEZ 101-•000,439-318 $2,i89.95 FEE DEPOOIT 1.01-000.439»318. -$1,250"011 M-ECHARriC:AL. PEE 101-000-421-000 $232.00 ELG* IACCAL FBE 101.000.420.000 $06.31 PLt)MBIAf0 P W 101-000-419-000 $707.50 VRONO i4it5TWX FIM, - Rrt.%. D 1,01.000.241.0360 $72,45 ORAJENNi'O FEE 101-000-4,23-0100 $15:00 OL'VELOPM IMPACT 1ERF $2,485,00 PFiECISK P .A14 101-000.441445 $'-100.00 ART IN PUBLIC 'PLACES - RESM 210.000-445»000 52,31,us :NI349rAL C'0]3"J'.11.M(MI N AND PLAW CHECK _. TZ 551 PRE -PAID 1,M l3IJX NOW -$1,250,1)(3 LFEBXMI,1:7R.Ui.:S•YLTS 2 6 2004 CITY OF IA O111NTA FINANCE DEPT. RECEIPT DATE BY-- DATE FINALE/DD INSPECTqFy INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts _ Slab Grade Return Air Steel Combustion Air. Roof Deck Exhaust Fans O.K. to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final BLOCKWALL APPROVALS POOLS - SPAS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final I I Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: ° i i LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9'(commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and -effect. License # Lic. Class Exp. Date 5187113 L3HI Date Signature of Contractor OWNER -BUILDER DECLARATION 3 0131.l2C I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). . ( ) I am exempt under Section B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier STATE FUND Policy No. 72-;-4905-2004 (This. section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes. Signature (Owner/Agent) Date BUILDING PERMIT' PERMIT# 03110.4293 DATE VALUATION LOT TRACT 0212�I17AC 274 ^ 298N_2 JOB SITE NO N ADDRESS &3-33 TM VISSA OWNER CONTRACTOR /DESIGNER/E .LSF; Y %3 HORN►I3 I 1� :6�I '1 i -a ['vC xffm:tIrnga' 49641 AVI A TSR POST EiPY CE DTs'.AWh-X 4,65,15 I QIUMA. CA 92253 W -IM T ESZM- `i' CA 9220-0 (76P)346r3366 C 14 2196 USE OF PERMIT ,Tc"1T..F' PANTY, IY wa-UNG $Sig SF SI''O-LOT 27NPERHd IT DOES ]:41. 9' INCLUng POtJi.JSPA OR BLOCK X1 &L1,8, 2001 CSC. Ci=°ATOM CONSTRUCTIf 81593.00 sig PORCH/P,A1110 1,490100 SF FS'I:iMATED COST OF L"O S7['Rtl'MIi; N 724,500SO `ice E^cIt/ r YiMR 611M ANRY crr3klrT1tUC'1'ION FIE9 101.000.418.000 $2,714,50 VI A14 CHECK ",I, .101-000-439-318 FFM DEPOSIT 101.000.439.318 -$1,250.90 MECHANICAL; .FEE 101.0013-421-000 $252.00 ELECTIUCAL 'p EE 101-000-420-000 2436,=11 'PLtiMEf1`Ro ME 101-000-419-000 $3.0.50 STRCM .t OTION, FEE -11111D 101.000.241.0100 M0 ORLADINQ PE -E 101-000-423-000 $15.00 DEVELOPER IMPACT FFF 'SZ405,00 PPF t"n! P*LAN 101-000.441-345 $180.00 ART IN PUBLIC PLACU - RESIL 270-000.445.000 $1,3t 1.25 e7ti.lA-s-WfAt.r COYoJ.RtlCTICNIT A3T. D PUN Cl:,.t`J.. K $9,604.4f LESS RUE -PAID FEW <$1,250.00 ` (YJCA1 PJ!M s Xr 1+'1yEN DUE HOW 95! 4A6 RECEIPT DATE BY DAT FINALED INSPECTOR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE I INSPECTOR BUILDING APPROVALS Set Backs MECHANICAL APPROVALS Underground Ducts _ _ _ Forms & Footings ( Ducts Slab Grade Return Air _ _ Steel Combustion Air _ Roof Deck Exhaust Fans O.K. to Wrap XA y F.A.U. Framing Compressor Insulation Vents Fireplace P.L. W77_ Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath — Drywall - Int. Lath - S Final Final BLOCKWALL APPROVALS POOLS - SPAS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING PPROVALS Gas Test Electric Final Waste Lines Heater Final _ Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring I Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power S Final Utility Notice (Perm) COMMENTS: .p C - ��� �� \ ,- `�,�,C� • ���Q �,...._�,` 1YYYl vV 11/ln��� 4 L 7 `A _ /� s l� � �y`��"L C r Pleisel i1�2i�y�L7%lss 5 - 311 VIA Ti • Buildingf J rf Address f f Mailing Address J 4 4 QuAto P.O. BOX 1504 78-495 CALLE TAMPICO QUINTA, CALIFORNIA 92253 City( Zip ( State I Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that 1 am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5.Susiness and Professions Code: Any city or county which requires a permit to construct, atter. Improve, demolish, or repair any structure, prior to its Issuance also requires the applicant for such permit to rile a signed statement that he Is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division3 of the Business and Professions Code. or that. he is exempt therefrom, and the basis for file alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of nor more than five hundred dollars ($500). l; I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Suisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of Completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I'1 1, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who contracts for such projects with a confractoris) licensed pursuant to the Contractor's License Law.) i? 1 am exempt under Set. B. 8 P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company rl Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS'COMPENSATIONINSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of th? work. for which this permit is issued, I shall not employ any person in any manner so as t0 become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip 3 03 APPLICATION ONLY WING: TYPE'C`OON`'STT.'5,r _/ � OCC. /GRP. Number 1—x l/ ?, U �� V al Description i l (7 , ? 'rl� l _I � `? f ' CMA i , �... " IZlp� TAA ITeI.J l:%OR Description Sq. Ft.� No. Size �- Sto No. DIN. New Add ❑ Alter ❑ Repair ❑ Demolition ❑ Zip�j ^ '� = Tel State Lic City & Classif Plan Chk. Dep. Lic. # Arch., Engr., .,__Designer/`�_ Const. Mech. Address Electrical Tel. 4 4 QuAto P.O. BOX 1504 78-495 CALLE TAMPICO QUINTA, CALIFORNIA 92253 City( Zip ( State I Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that 1 am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5.Susiness and Professions Code: Any city or county which requires a permit to construct, atter. Improve, demolish, or repair any structure, prior to its Issuance also requires the applicant for such permit to rile a signed statement that he Is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division3 of the Business and Professions Code. or that. he is exempt therefrom, and the basis for file alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of nor more than five hundred dollars ($500). l; I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Suisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of Completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I'1 1, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who contracts for such projects with a confractoris) licensed pursuant to the Contractor's License Law.) i? 1 am exempt under Set. B. 8 P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company rl Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS'COMPENSATIONINSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of th? work. for which this permit is issued, I shall not employ any person in any manner so as t0 become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip 3 03 APPLICATION ONLY WING: TYPE'C`OON`'STT.'5,r _/ � OCC. /GRP. Number 1—x l/ ?, U �� V al Description i l (7 , ? 'rl� l _I � `? f ' CMA i , �... " IZlp� TAA ITeI.J l:%OR Description Sq. Ft.� No. Size �- Sto No. DIN. New Add ❑ Alter ❑ Repair ❑ Demolition ❑ REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line FINAL DA Issued by: Validated Validation Side Setback from Property Line WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION Estimated Valuation PERMIT AMOUNT .n: 7 Plan Chk. Dep. Plan Chk. Bal. -77 f Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line FINAL DA Issued by: Validated Validation Side Setback from Property Line WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION Coacjhella.,Valley Unified scnool vislriclt P.O. Box"147, Thermal, CA 92274 ;760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEEPT: CHECK H: MITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Hideway Date: February 26, 2004 Owner's Name: Jerry D Horn Phone No. Project Address: 53-317 Via Pisa La Quinta, CA 92253 Project Description: 1 SFD APN: 775-520-020 Tract #: 29894-2 Lot #'s: 274 Type of Development: Residential X3= Commercial Total Square Feet of Building Area: 8,555 sq. ft. Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: 0 Signatur r,r**r•,w«,r*,w*«.,►*+rt*,r***i*********•*****•wrw**.*r,►,t**«*rr,►ww,rrw*rw,rr*** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project 17620 65995 Approval Number of Sq -Ft- 8,555 Amount per Sq.Ft. _ $ 2.19 Amount Collected $ 18, 735.45 Building Permit Application Completed: Yes/No By: Carey M. Carlson Asst. Supt., Business Serv. Agreement Existing Not Subject to Fee Prior to 1/1/87 Requirement Note: Certificate issued by: El V i ra, Mattson Signature: Office Technician NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. MV:c/mydocs/devfees/certificate of compliance 09/30/02 WHEN RECORDED hAIL TO: Rnrn , .T,-rry 19 Heather Hill Ln SHeridan, Wy 82801-9046 MAIL TAX STATEMENT TO: Same as above A ®®C = 2003-041070 01/17/2003 08:00A Fee:19.00 Page 1 of 5 Doc T Tax Paid Recorded in Official Records County of Riverside Gary L. Orso Assessor, County Clerk 8 Recorder 11111111111111111111111111111 N 1111111111111111111 M $ U PAGE SLE DA PCOV NOCOR SMF "Sc. * R L COPY IONG REFUND NCHG EXAM DOCUMENT TRANSFER TAX $-'4?. X Computed on the consideration or value of property conveyed; OR Computed on the consideration or value less liens or encumbrances YS_` remaining at the time of sale. l5 , c q O • o a O . � Signature of Declarant or Agent determining tax - Firm Name TQ -ft -. o 9-0 0 5 -LP GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company ("Grantor"), hereby GRANT(S) to ,Terry D Horn a Mar ri Pd Man ag ** ("Grantee"), the real property located in the City of La Quinta, County of Riverside, State of California, described as: ** His Sole and Seperate Property See Legal Description attached hereto and incorporated herein as Exhibit "A". SUBJECT TO all matters of record including, without limitation, the covenants and agreements described in Exhibit "A" attached. hereto. Dated: 12-27-02 1-LA/627969.1 1 ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company By: Nationwide Realty Investors, Ltd., an Ohio limited liability company its managing member % By: �x,./, President and Chief Operating Officer STATE OF • ) ss. ' COUNTY OF 1 Vern, i d Ong' (ID 2002, before me, the and s fined, a notary public in and for. said State, personally app ared J S Vi L . Arenszr ,, ,v personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(`s,) is/kge subscribed to the within instrument and acknowledged to me that he/s'he/they executed the same in his/hWth'bk authorized capacity(ies), and that by his/hbr/ftr signatureN on the instrument the person(3.), or the entity upon behalf of which the personN acted, executed the instrument. WITNESS MY HAND AND OFFICIAL SEAL. Signature -,,Mm Aa ., [SEAL] KATHRYN L. HUNTER Commission # 1382692 Z , .m Notary Public - California Riverside County MY Comm. Expires Nov 1, 2006 111111 till lilt, lilf till IIIM III nill it, w, 2003-041070 1-1,,•1/627969.1 2 Parcel No. 1: EXHIBIT "A" Legal Description. Lot 274 (the "Lot") of Amended Tract No. 2 9 8 9 4_ 2 as shown on a Subdivision Map (the "Map") recorded on _DECEMBER 12, 2002 , in Book 327 ,Pages 56 to 88 , inclusive, of'Maps, in the Office of the Riverside County Recorder. EXCEPTING AND RESERVING THEREFROM TO GRANTOR, and its successors, assigns, invitees, licensees and employees, together with the right to grant and transfer all or a portion of the same, all easements and rights for access, ingress, egress, encroachment, maintenance, drainage, support, and for other purposes over the Association Maintenance Areas and other portion of the Lot, reserved to Grantor in the following instruments: 1. The Amended and Restated Declaration of Covenants, Conditions and Restrictions and Reservation of Easements for The Hideaway Owners Association (as amended or supplemented, the "Declaration"), recorded onDECEMBER 13 , 2002, as Instrument No. 2002= v - f i 2. All other covenants, conditions, restrictions, reservations, easements, rights and /rights-of-way of record including, without limitation, the Declaration and the Map for Tract No. 29894-2 Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in this Grant Deed, (b) grants to Grantor and The Hideaway Owners Association such powers and rights as are set forth in the Declaration ,and (c) accepts, covenants and agrees to be bound by and assume performance of all of the applicable provisions and requirements set forth in the Declaration, including Section 3.15 establishing the procedure for resolving disputes with Grantor, and. the notice, which provisions and requirements are acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be performed by Grantee under the Declaration. The restrictions on use and occupancy of the Lot are set forth in the Declaration to which this Grant Deed is specifically and expressly made subject. GRANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING, granting unto Grantor and The Hideaway Owners Association such powers and rights which are set forth in the Declaration defined above; STATE OF�.��.�Q„jl ) COUNTY ss. OF��,��'S�d e, ) Q� On O. ,fit, before me, the undersigned, a notary public in and for said State, personally appeared l Q r Q_ }gyp(' n personally known to me (or proved to me on the basis of satisfactory evi ce) to be the person(s) whose names is subscribed to the within instrument and acknowled ed to me thalh /shchhey executed the same inQhetlffeir authorized capacity(ies), and that b ih' /herftheir-signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument.' WITNESS MY HAND AND OFFICIAL SEAL'. Signature P --2k[SEAL] IN0 ; ;.a 0 .3 Cl 8 : ,o,. of 5 I-LA/627969.1 4 r C:o tt cJi .::fur: K 1346326 z Ca!i`cmia z > 7i^.. .. m—". ii, 2 AF :.DV- PIC;SSO-MOORE C_ Ptni=�;irsn 1346326 z n: -,ids County ' E. ier 11' 2C b LI/ i' GOVERNMENT CODE 27361.7 i jl I HEREBY CERTIFY UNDER PENALTY OF PERJURY THAT THE NOTARY SEAL ON THE DOCUMENT TO WHICH THIS IS ATTACHED READS AS FOLLOWS: NAME OF NOTARY: ARROW PICASSO-MOORE DATE COMMISSION EXPIRES: MARCH 11, 2006 COMMISSION NUMBER: 1346326 COUNTY WHERE BONDED: RIVERSIDE PLACE OF EXECUTION: RIVERSIDE COUNTY, CALIFORNIA DATE: JANUARY 17, 2003 jp�jqj)M6 FIDELITY NATIONAL TITLE BUILDER SERVICES YOUNG ENGINEERING SERVICES 77-504 Wildcat Dr., Ste. C, Palm Desert, CA. 92211 (760) 360-5770 fax (760) 360-5719 January 16, 2004 Tom Hartung Building Official City of La Quinta Re: Horn Residence, The Hideaway, Tract 29894-2, Lot 274, La Quinta, Ca Dear Tom, We have reviewed the truss calculations provided by Foxworth Galbraith Truss Company for the above-mentioned project and find them to be in general conformance with our design intent. If you have any questions please call. C J VkX No. 4044 Certificate of Occupancy- U ��GI�Cv Inmcoon�n� c OF'LBuildin & Safet Department 9► Y_ p This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. q BUILDING ADDRESS: 53-317 VIA PISA Use classification: S.F.D. Building Permit No.: 0310-293 Occupancy Group: R-3 Type of Construction: V -N Land Use Zone: R -L Owner of Building: JERRY HORN Address: PO.DRAWER 4656 City, ST, ZIP: PLAM DESERT CA 92261 By: G. SHOWALTER Date: 08/26/05 - Building Official POST IN A CONSPICUOUS PLACE TANDrS ' INSPECTION INC. PO BOX 13766 PALM DESERT, CA 92255 SPECIAL INSPECTION DAILY REPORT OFFICE/FAX 909.769.9717 PAGER 760.776.3339 TYPE OF INSPECTION PERFORMED 1��pm<k4 SAMPLE INFORMATION I TICKET NUMBER MIX NUMBER DAT I -k �_ PHYSICAL ADDRESS PERMIT NUMBER - - -TY 09 JOB NAME f WELDING INFORMATION OF`STRUCTURE ARCHITECT WELDERS NAME ENGI ER OC,l1.�,rG GENERAL CONTRACTOR SUB CONTRACTOR S -T O kf ry S OF WORK I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING LAWS. CC: INSPECTORS SIGNATURE INSPECTORS CERTIFICATION AGENCY AND NUMBER SAMPLE INFORMATION SUPPLIER TICKET NUMBER MIX NUMBER TIME AIR TEMP SAMPLE SAMPLED TEMP SLUMP TIME IN MIXER LOCATION WELDING INFORMATION PROCESS WELDERS NAME CERTIFYING AGENCY AND CERTIFICATION NUMBER I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING LAWS. CC: INSPECTORS SIGNATURE INSPECTORS CERTIFICATION AGENCY AND NUMBER SPECIAL INSPECTION DAILY REPORT TAN DY'S INSPECTION INC. PO BOX 13766 PALM DESERT, CA 92255.3766 OFFICE/FAX - 909.769.9717 PAGER - 760.776.3339 DESCRIPTION OF WORK INSPECTED 5/3-5/4-5/5-5/6-5/7-5/10-5/11 OBSERVED SINGLE PASS AND COMPLETE JOINT PENETRATION WELDING ON COLUMNS AND BEAMS. SEE ATTACHED FABRICATION REPORT. SHOP WELDING COMPLETE 5/12 - COLUMNS 1 A & 1 B AND BEAM 3A CJP WELDS PASSED ULTRASONIC TESTING BY INLAND INSPECTION. 5/27 - ALL FIELD CJP WELDS PASSED ULTRASONIC TESTING BY INLAND INSPECTION. WELDING INFORMATION DATE TYPE OF INSPECTION PERFORMED SHOP WELDING CERTIFYING AGENCY AND CERTIFICATION NUMBER 27 -May -04 PHYSICAL ADDRESS PERMIT NUMBER 53317 VIA PISA- LA QUI NTA 310293 JOB NAME TYPE OF STRUCTURE HORN RESIDENCE @ THE HIDEAWAY SFD ARCHITECT ENGINEER VISUAL FRONTIERS YOUNG ENGINEERING GENERAL CONTRACTOR SUB CONTRACTOR STEVEN JONES WHITES STEEL DESCRIPTION OF WORK INSPECTED 5/3-5/4-5/5-5/6-5/7-5/10-5/11 OBSERVED SINGLE PASS AND COMPLETE JOINT PENETRATION WELDING ON COLUMNS AND BEAMS. SEE ATTACHED FABRICATION REPORT. SHOP WELDING COMPLETE 5/12 - COLUMNS 1 A & 1 B AND BEAM 3A CJP WELDS PASSED ULTRASONIC TESTING BY INLAND INSPECTION. 5/27 - ALL FIELD CJP WELDS PASSED ULTRASONIC TESTING BY INLAND INSPECTION. I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK INSPECTORS SIGNATU TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING LAWS' ICC 1111326 - CC: - INSPECTORS CERTIFICATION AGENCY AND NUMBER WELDING INFORMATION PROCESS FCAW - E71 T-8 & SMAW - E7018 WELDERS NAME CERTIFYING AGENCY AND CERTIFICATION NUMBER ELOY CHAVEZ EARTH SYSTEMS #ES1275 ELISEO VASQUEZ EARTH SYSTEMS #ES1038 LUIS TORRES EARTH SYSTEMS #ES1242 GUADALUPE AMAVICA EARTH SYSTEMS #ES1183 ISHMAEL AYALA EARTH SYSTEMS #ES4001 I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK INSPECTORS SIGNATU TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING LAWS' ICC 1111326 - CC: - INSPECTORS CERTIFICATION AGENCY AND NUMBER .a STRUCTURAL STEEL SHOP WELDING FABRICATION REPORT Job Name: H012U 1363. ® 'TC7 #t l O t:;AW A �( Contractor. S T&11C7 - c,)D�tl� Engineer. Yo u IOL— Architect V t S u R L, EP -c t4-r'i E*,'S "- -- Fabricated at testi i Ml S LS Start Date: 5 3 , 01f Finish Date: 5,T-11 a `f All materials conform to approved plans, specifications, AISC, and AWS D1.1 unless noted. • ACC in SINGLE PASS or CJP WELDING columns represents acceptable welding and no corrective work required. NDT stands for Non -Destructive Testing such as Ultrasonic or Magnetic Particle om�o M EMMEM mmm MMEMINEM mmm M wmm� m0�u�m� OM mm mmmm i MM B= mm All materials conform to approved plans, specifications, AISC, and AWS D1.1 unless noted. • ACC in SINGLE PASS or CJP WELDING columns represents acceptable welding and no corrective work required. NDT stands for Non -Destructive Testing such as Ultrasonic or Magnetic Particle TANDY'S ---- INSPECTION INC. PO BOX 13766 PALM DESERT, CA 92255 OFFICE/FAX 909.769.9717 SPECIAL INSPECTION DAILY REPORT PAGER 760.776.3339 TYPE OF INSPECTION PERFORMED JDATE t PHYSICAL ADDRESS 50-3``t — PERMIT NUMBER 031 61.1a3 JOB NAME TYPE OF STRUCTURE ARCHITECT ENGINEER S—%lC-:7-JE 30aJE GENERAL CONTRACTOR SUBCONTRACTOR DESCRIPTION OF WORK INSPECTED u W ELbr- '�: �� ui .E_ uta 1 SAMPLE INFORMATION SUPPLIER TICKET NUMBER MDL NUMBER SAMPLED MP TEMP STEMFE SLUMP TIME IN MIXER LOCATION WELDING INFORMATION PROCESS tA41 W WELDERS NAME CERTIFYING AGENCY AND CERTIFICATION NUMBER ZyI- . co TA ruts oc� -3a. I HERESY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK UNLESS OTHEJiWM NOTED. MID TO THE BEST OF MY ABILITY I HAVE POUND THIS NS ORS SIGNATURE WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS 6 HPPUCABLE q SUILOM LAWS. G.1 !i_=-- INSPE TORS CERTIFICATION AGENCY AND NUMBER CC: tg%i TANDY'S INSPECTION INC. PO BOX 13766 PALM DESERT. CA 92255 SPECIAL INSPECTION DAILY REPORT OFFICE/FAX909.769.9717 PAGER 760.776.3339 TYPE OF INSPECTION PERFORMED SAMPLE INFORMATION DATE of AIR TEMP 8AMPLED , ,t PHYSICAL ADDRESS S'o - 31� PrS�4 PERMIT NUMBER b31 OAS 'O` NAME TYPE OF STRUCTURE i O o.j LA �j L ARCHITECT ENGINEER S -i -EVE' �,wE GENERAL CONTRACTOR SUB CONTRACTOR yG 1 HEREBY CERTIFY THAT 1 HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY 1 HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS 8 APPLICABLE BUILDING LAWS. CC: �.PECTORS SIGNATURE _Jr -c I?G ht-ec INSPECTORS CERTIFICATION AGENCY AND NUMBER SAMPLE INFORMATION SUPPLIER TICKET NUMBER MIX NUMBER AIR TEMP 8AMPLED SAMPLE SLUMP TIME IN MIXER TEMP LOCATION WELDING INFORMATION PROCESS WELDERS NAME CERTIFYIN AGENCY AND CERTIFICATION NUMBER yG 1 HEREBY CERTIFY THAT 1 HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY 1 HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS 8 APPLICABLE BUILDING LAWS. CC: �.PECTORS SIGNATURE _Jr -c I?G ht-ec INSPECTORS CERTIFICATION AGENCY AND NUMBER vM w 01/04/2005 09:09 17603401819 PARAGON/SCHMID BUILDING PRODUC'T'S MAIL TO: 74-741 JONI DRIVE #A PALMDESERT, CA 92660 �I 760-346-2339 X117 FAX 760-340.1919 iALIRERSOIVAL ATTN: ED RANDA LL (BUILDING DE" COMPANY: STF,PHE.'' JONS CONSTRUCTION FAX NUMBER: 777 7011 PHONE NUMBER: DATE: 1/4/2005 FROM: VOLANDA CANT PIlONE:760-346-23:;9 X117 FAX: 760-340-1819 E -Mail: yolanila.gant@nmascocs.com TOTAL OF PAGES IN FAX INCLUDMQ COVER PAGE: YOUR REFERENCE, r- IJMBER,TROJECT: PIE X URC -ENT X PLEASE RESPOND [HERBS THE INSULA'I IiON CERTIFICATES THAT YOU WERE REQUESTING, IF YOU HAVE, ANY IQUFSTIONS PLEASE AVE MR A CALL, MY NUMBER IS LOCATED AT THE TOP OF T HIS FAX. (I'LL PUT YOUR ORI(: INAL$ IN THE MAIL. keep me up Bated (in the status of the invoice(s). 1, I APPRECIATE ALL OF YOUR HELP:) O �� Ydiee FAX COVER PAGE 01/02 U TITLE 24 REPORT Title 24 Report for: Horn Residence Lot 274 The Hideaway La Quinta, CA 92253 Project Designer: Stephen Jones Design & Construction, Inc. P.O. Drawer 4656 Palm Desert, CA 92260 (760) 346-3366 Report Prepared By: C.J. Mcfadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 CITY OF LA �UioEPA Job Number: BUILDING & SA AP oR0!/EID 0004.00 FOR C DATE tON BY Date: 1/15/2004 f r -The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is . authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 0004.00 User Number: 3665 Ss 4p %5D Zoa C8C..' Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Horn Residence 1/15/2004 Project Title Date Lot 274 The Hideaway La Quinta Exterior Roof Project Address Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Check/Date Documentation Author Telephone Solid Wood Door Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Wood Total Conditioned Floor Area: 7,277 ft2 Average Ceiling Height: 11.1 ft Total Conditioned Slab Area: 7,038 ft2 Slab On Grade Building Type: 0.756 (check one or more) Slab On Grade X❑ Single Family Detached ❑ Addition 0.756 ❑ Single Family Attached ❑ Existing Building Front ❑ Multi -Family ❑ Existing Plus Addition 59.3 Front Orientation: (Northeast) 45 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 ScreenX❑ Number of Stories: 3 ® Raised Floor w 0 Component Vie_ Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) R-38 Roof (R.38.2xl4.16) Wood 0.027 Exterior Roof R-23 Certinty (blown in) Wall Wood 0.057 Exterior Wall Solid Wood Door Wood 0.387 Exterior Door R-23 Certinty (blown in) Wall (W-2) Wood 0.064 Exterior Wall Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab WR -0.0 Perimeter Insulation R-30 Floor (F.30.2x10.16) Wood 0.034 Exterior Floor / Over Open Space FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Right (North) 13.5 0.44 0.26 Bug Screen X❑ ❑ ❑ X❑ Front (Northeast) 59.3 0.44 0.26 Bug ScreenX❑ ❑ ❑ X❑ Front (East) 58.5 0.44 0.26 Bug Screen X❑ ❑ ❑x❑ Left (South) 10.5 0.44 0.26 Bug Screen X❑ ❑ ❑ X❑ Rear (West) 55.7 0.44 0.26 Bug ScreenX❑ ❑ ❑X❑ Front (Northeast) 474.4 0.38 0.42 Bug Screen[i] ❑ ❑X❑ Left (Southeast) 70.6 0.44 0.26 Bug Screen X❑ ❑ ❑X❑ Left (Southeast) 381.0 0.38 0.42 Bug Screen X❑ ❑ ❑ X❑ Left (South) 160.0 0.38 0.42 Bug Screen X❑ ❑ ❑ X❑ Rear (Southwest) 44.5 0.44 0.26 Bug Screen x❑ ❑ ❑X❑ Rear (Southwest) 300.0 0.38 0.42 Bug Screen x❑ ❑ ❑ X❑ Right (Northwest) 62.3 0.44 0.26 Bug ScreenX❑ ❑ ❑ X❑ Run Initiation Time: 01/15/04 08:12:10 Run Code: 1074183130 Ener Pro 3.1 By Ener Soft User Number: 3665 Job Number: 0004.00 Pa e:3 of 53 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Horn Residence 1/15/2004 • Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 6.0 Setback HVAC -7 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 16.0 SEER Ducts in Attic 60 Setback HVAC -7 WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value LJ 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storace water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: C.J. Mcfadden Title/Firm: Stephen Jones Design & Construction, Inc. Title/Firm: BREEZE AIR CONDITIONING Address: P.O. Drawer 4656 Palm b sertCA 92260 Telephone: 760 34.6-3366 11 Lic. #:'S -L- p -Ic :A�- (signatur6)------'(date) Enforcement Agency Name: Title/Firm: Address: Telephone: Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 1 15 p (signature (date) IEnergyPro 3.1 By EnergvSoft User Number: 3665 Job Number: 0004.00 Page:5 of 53 1 Certificate of Compliance: Residential (Addendum) CF -1 R Horn Residence 1/15/2004 •Project Title Date +Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field 40 Ll The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -2" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -2" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 964 sqft Tile in Mortar Interior Mass, 0.75" thick at First Floor HIGH MASS Design(see C -2R) - Verify Thermal Mass: 964 sqft Exposed Slab Floor, 4.00" thick at First Floor HIGH MASS Design(see C -2R) - Verify Thermal Mass: 241 sqft Covered Slab Floor, 4.00" thick at First Floor The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -3" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -3" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 165 sqft Tile in Mortar Interior Mass, 0.75" thick at HVAC -3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 165 sqft Exposed Slab Floor, 4.00" thick at HVAC -3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. I Plan I Field The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Ir The HVAC System "HVAC -4" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -5" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 01/15/0408:12:10 Run Code: 1074183130 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:6 of 53 Certificate of Compliance: Residential (Addendum) CF -1 R Horn Residence 1/15/2004 •Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. i—PlanIField • i� HIGH MASS Design(see C -2R) - Verify Thermal Mass: 663 sqft Covered Slab Floor, 4.00" thick at HVAC -3 The HVAC System "HVAC -4" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -4" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -4" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -4" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 698 sqft Tile in Mortar Interior Mass, 0.75" thick at HVAC -4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 698 sqft Exposed Slab Floor, 4.00" thick at HVAC -4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1046 sqft Covered Slab Floor, 4.00" thick at HVAC -4 The HVAC System "HVAC -5" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -5" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -5" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -5" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1359 sqft Tile in Mortar Interior Mass, 0.75" thick at HVAC -5 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. I Plan I Field The HVAC System "HVAC -5' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -6" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -6" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -7" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -7" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 01115/0408:12:10 Run Code: 1074183130 EnergyPro 3.1 By Energysoft User Number: 3665 Job Number: 0004.00 Page:7 of 53 Certificate of Compliance: Residential (Addendum) CF -1 R Horn Residence 1/15/2004 .Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field lu • HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1359 sqft Exposed Slab Floor, 4.00" thick at HVAC -5 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 239 sqft Covered Slab Floor, 4.00" thick at HVAC -5 The HVAC System "HVAC -6" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -6" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -6" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -6" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 941 sqft Tile in Mortar Interior Mass, 0.75" thick at HVAC -6 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 941 sqft Exposed Slab Floor, 4.00" thick at HVAC -6 HIGH MASS Design(see C -21R) - Verify Thermal Mass: 95 sqft Covered Slab Floor, 4.00" thick at HVAC -6 The HVAC System "HVAC -7" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -7" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -7" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -7" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC aooroved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures ori a form CF -6R. Plan Field Run Initiation Time: 01/15/0408:12:10 Run Code: 1074183130 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:8 of 53 Certificate of Compliance: Residential (Addendum) CF -1 R Horn Residence 1/15/2004 •Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 0 • )aseo on the aaequacy of the special jusuncation ano aocumentation sunmittea. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 627 sqft Covered Slab Floor, 4.00" thick at HVAC -7 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures ori a form CF -6R. plan Field Run Initiation Time: 01/15/04 08:12:10 Run Code: 1074183130 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:9 of 53 • 0 • Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures 1150(a): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. ❑X "§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). ❑ ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. a§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑X §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures Al §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. E] §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. FX §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 10 of 53 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R 140TE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (") may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into • the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) FX]'§ 150(m): Ducts and Fans t 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. RI§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures §150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 11 of 53 Computer Method Summary (Part 1 of 3) C -2R _dorf3-Residence 2.77 1 /15120-04 Title 3.92 Date �Project 1ot 274 Th cleawa_y-La_Q_uinta 37.07 -0-057 90 90 Project Address 00.57 94 90 Building Permit # BBEEZEAIB_CONDI_T_l_QN.LNG (760) 346-0855 0057 -2.7.0. 90 Documentation Author Telephone pian Check/Date Computer�elfolmanCe 15 0034 0 080 Field Check/Date Compliance Method (Package or Computer) Climate Zone -(_05.1 0 9.0_ Source Energy Use Standard Proposed Compliance Wall_ 3.fa (kBtu/sf-yr) Design Design Margin 0 057 X30 90 Space Heating Space Cooling Domestic Hot Water Totals ard: Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: 4.04 2.77 33.67 29.07 3.92 5.23 41.63 37.07 -0-057 90 90 Wall- 8.5 00.57 94 90 BUILDING I BUILDING ZONE INFORMATION Zone Name •riva�-4 JiVAC_5 7,277 ft2 Single Fam Detached (Northeast) 45 deg 1.00 3 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Floor Area Volume Rooms 1167 0- 21 340 0 Wall- _54- -0-057- 0 _90_ Door 24 _0_3.87_ _0_ _90 Wall_ ____JAQ 0..464_ 0 90 Wall_ _224 -0-057 90 90 Wall- 8.5 00.57 94 90 Wall- 58 0064 080 _90 Wall- X30 0057 -2.7.0. 90 DO.or 24 _09.87 270 90 Wall- x.50_ _0_0-64. 37.0 ---9.0- -Boor--- ____38_ 0034 0 080 _Boni__201 0927_ 3A0 0 Wall- 3.6_ -(_05.1 0 9.0_ Wall- 47 0.057 45 90_ Wall_ 3.fa -O-G57- 90 90_ Wall_ 47 0 057 X30 90 Wall_ 36_ -0-0.5.7- 08.0 90 Wall_ 47 _Q..Q5.7- -225 90 Wall- 36 -0-037- 310--99 Wall- 47 0-457 310 90 Floor _2.01 0-.034 0 ---180- 80Root Roof-8211 _0_027- -340 _0_ Wall_ _20- 0 057 ___A5_ 90_ Wall- 92 00.57 035. 90_ Wall- _280 -(_0.57 -225 90_ Root- x..744 -0-02.7- 3A0 0 Wall_ _2.94 0.064- 0 _90- 0Wall- Wall-47 001 080 90 Wall- 56 0057 320 90 1 444 828 1,744 1.598 Solar Gains Y/N __1U2_4 12.420 1-8,66-1 19.17_6 1.28 4.60 -1.32 4.56 11.0% Floor Construction Type: 0 Raised Floor XI Slab Floor Total Fenestration Area: 23.2% Total Conditioned Volume: 81,130 ft 3 Total Conditioned Slab Area: 7,038 ft 2 # of Thermostat Vent Units Zone Type Type Hgt. Area -020_ 1 iv" g -I ivingS.tat- 8 -n a 0"11 Living_LivingSlat- 8 _n/a 024- Sleeping -Sle ping.Slat_ 8 _n/.a -0-22- Living I iving_Stat__ 8 _nLa Form 3 Reference g38_R0J (&38 14..1.6.) R 23_C etf i nty�blo w� i n)-1 N a I I _S.olid Wood -Door B_2 C�rtinty (bloyxn in) WaILCW-2) _R-23_Cettinty_(blown tn) Wal I R-23 Ce�finty (blown i Wall B23�e�tinty�blownin)_WaIW I rW-2j_ B23_Celfiaty�blo�yn in) Wall _SoJkLWood_D9nr R23 Cedinty (blown in Wall (W-22) R30_R0oL(E 30 2x1016) _B_38Roof (R )S_2x14.16) R-23 Certinty (blown in) Wall R23_Certinty_(b1ownin)_Wal I R23_Cei"_(Wown in) Wall R23 Ce�inty (blown in) Wall -R--23-C (blown in) Wall R23_Cer intMblow.n in) Wall R23_Cediaty_(b1own W_WAlI R23_CeAinty_(Wmn in) Wall _B_30_FJ.OJDL(E.34.2xM_6.) R38Roof IR.382x14.1A R23_Ce.�3inty (blown�n) V1Call R23 Ce�3inty�blown in) all R23_Ce6nty_(blawn in,) Wall R38Boof (R.302xL416) R23 Celfinty.jblown in) WAUWzZ R23_C2lfinty_( all JiVAC-2 HV C_9 HVA_ C-2 H r-2 HV C-2 H C-9 HVAr-2 JiVAC-2 H C-2 H C-2 H C-2 JiVAC-2 JTV.AC-2 H -2 HVAC -2 JivAr.-2 .kLVAC-2 HVAC -3 H r'-3 J±VAG3 Location / Comments EnergyPro 3.1 By EnergvSoft User Number: 3665 Job Number: 0004.00 Page:12 of 53 Computer Method Summary (Part 1 of 3) C -2R _I.orn_Residenne 1/15120-04 Title Solar OPAQUE SURFACES Date WProject lo _27A The — Hideaway La_Quinta Type Area U -Fac. Azm. Tilt Y / N Project Address ' —0-057- —27-0 _90- 0Wall— Building Permit # BREEZE AIR CONDITIONING -Wall 40 (760) 346-0855 Documentation Author Telephone Plan Check/Date Comute�elfomlance 15 Roof— x...598 Field Check/Date Compliance Method (Package or Computer) Climate Zone -Wall _12.9 Source Energy Use Standard Proposed Compliance ❑ (kBtu/sf-yr) Design Design Margin IN Space Heating 4.04 2.77 1.28 Space Cooling 33.67 29.07 4.60 —0-0-0-057-O�—315 —90 Domestic Hot Water 3.92 5.23 -1.32 Roof— 036_ Totals 41.63 37.07 4.56 ❑ than Standard: 11.0% Total Conditioned Floor Area: 7,277 ft Floor Construction Type: X❑ Raised Floor ❑X Slab Floor Building Type: Single Fam Detached Building Front Orientation: (Northeast) 45 deg Total Fenestration Area: 23.2% Number of Dwelling Units: 1.00 Total Conditioned Volume: 81,130 ft 3 Number of Stories: 3 Total Conditioned Slab Area: 7,038 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC_6 x.,.03.6 —.0153 0 14 Living _LivingS1at— 8 n/a .H_V.AC 7 627_ —6,8.97 _0_0.9_ Living _LLvingS.tat_ 8 _nLa • W_al.l_ 358 0057 035 90 LA_ LJ Wall— 158 —0-057- —22.5 _9A IX ❑ .Roo(— 627- 0.027 —345 0 X ❑ Wall_ 6.0 —0-05L 45 9.0 [X ❑ Wall_ 240_ _0_057- —225 90_ 6a ❑ Wall_ 300 0.0.52 —315 90_ D_Q ❑ _Door 24 0_387- —315 90_ [)Q ❑ Form 3 Reference R_23 Certinty ((blown in) Wall R23-Cettinty (blown-n)_WalL(W2)_ R23_Ce rtinty_(blow.n_ n)_Wall. R38Boof_(R_3&2x14.1&) B-23_CeAintk(blown.in) \tVall R23_CerSinty_(blawn inl Wall R23_Ce_tinty_(b1own in)1Nall R23_CertiriW blownin)_l_V_al I JR-3.8-Roof-(R38.2x1_4 l61 R23_.eA ty_(blon i Wall B23_sri1ilown i ) Wall(W-2-2) 823 CedbWblownin) Wall R-23 Certinty ((blown in) Wall B 38Boof (R. 38.2x14_].6.) R-23 Cerin (blown i all R23_Ce_dintk(b1ownin) Wall B-23S�ettinty (blown in)_Vfiall 1.01id 1L1/oodJZoor Location / Comments HVAC -4 HVAG_5 xVAC_5 HVAC -6 -6 HVAC -6 .IiVAC_6 HVA •=6 HVAC_6 HVAC -7 HVAC -7 _7 HVA HVAG_7 IiVAC-7 I EneravPro 3.1 By EneravSoft User Number: 3665 Job Number: 0004.00 Paae:13 of 53 1 Solar OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y / N Wall_ 26Z —0-057- —27-0 _90- 0Wall— -Wall 40 0_064_ —2.7-0 --90- 90Wall_ -Wall-40 —0-057- —315 90_ ❑ Roof— x...598 0_022 XA5_ —0- 0Wall_ -Wall _12.9 —0-057-4.5 90 ❑ Wall_ X04 —0-057- 035 90_ IN ❑ Wall_ 241 ---0-057- X2.5 90 [ ❑ -Wall 338 —0-0-0-057-O�—315 —90 X ❑ Roof— 036_ 0-027- _3A5_ 0_ ❑ Wall —249 0 057 ___A5 90 Wall_ 32 0-06A- 45 90 ❑ • W_al.l_ 358 0057 035 90 LA_ LJ Wall— 158 —0-057- —22.5 _9A IX ❑ .Roo(— 627- 0.027 —345 0 X ❑ Wall_ 6.0 —0-05L 45 9.0 [X ❑ Wall_ 240_ _0_057- —225 90_ 6a ❑ Wall_ 300 0.0.52 —315 90_ D_Q ❑ _Door 24 0_387- —315 90_ [)Q ❑ Form 3 Reference R_23 Certinty ((blown in) Wall R23-Cettinty (blown-n)_WalL(W2)_ R23_Ce rtinty_(blow.n_ n)_Wall. R38Boof_(R_3&2x14.1&) B-23_CeAintk(blown.in) \tVall R23_CerSinty_(blawn inl Wall R23_Ce_tinty_(b1own in)1Nall R23_CertiriW blownin)_l_V_al I JR-3.8-Roof-(R38.2x1_4 l61 R23_.eA ty_(blon i Wall B23_sri1ilown i ) Wall(W-2-2) 823 CedbWblownin) Wall R-23 Certinty ((blown in) Wall B 38Boof (R. 38.2x14_].6.) R-23 Cerin (blown i all R23_Ce_dintk(b1ownin) Wall B-23S�ettinty (blown in)_Vfiall 1.01id 1L1/oodJZoor Location / Comments HVAC -4 HVAG_5 xVAC_5 HVAC -6 -6 HVAC -6 .IiVAC_6 HVA •=6 HVAC_6 HVAC -7 HVAC -7 _7 HVA HVAG_7 IiVAC-7 I EneravPro 3.1 By EneravSoft User Number: 3665 Job Number: 0004.00 Paae:13 of 53 1 Computer Method Summary (Part 2 of 3) C -2R Horn Residence 1/15/2004 AlkProiect Title Date FENESTRATION SURFACES # Type 0.76 0.0 Area Ll- Factor SHGC Act. Azm. Glazing Type Tilt 2 -1- Window Riaht(Notth) -3_0 _0940- _0.26_ 0_ -90 Assumed_Glassing values 2 Window Front (Northeast) 12.5 0.440 0.26 45 90 Assumed Glassing values 3 Window Front (Northeast) 3.0 0.440 0.26 45 90 Assumed Glassing values 4 Window Front (Northeast) 7.5 0.440 0.26 45 90 Assumed Glassing values 5 Window Front (Northeast) 25.0 0.440 0.26 45 90 Assumed Glassing values 6 Window Front (Northeast) 7.5 0.440 0.26 45 90 Assumed Glassing values 7 Window Front (East) 3.0 0.440 0.26 90 9Q Assumed Glassing values 8 Window Front (East) 45.0 0.440 0.26 90 90 Assumed Glassing values 9 Window Right (North) 10.5 0.440 0.26 0 90 Assumed Glassing values 10 Window Front (East) 10.5 0,444 0.26 90 90 Assumed Glassing values 11 Window Left (South) 10.5 0.440 0.26 180 90 Assumed Glassing values 12 Window Rear (West) 10.5 0.440 0.26 270 90 Assumed Glassing values 13 Window Front_(Uodh-east) 20.8 -O-$Q 0.42 4,5- 9Q Ass_umed_Glassina values 14 Window Front (Northeast) 20.8 0.380 0.42 45 90 Assumed Glassing values 15 Window Front (Northeast) 20.8 0.380 0.42 45 90 Assumed Glassing values 16 Window Front (Northeast) 108.0 0.380 0.42 45 90 Assumed Glassing values 17 Window Front (Northeast) 108.0 0.380 0.42 45 90 Assumed Glassing values 18 Window Front (Northeast) 108.0 0.380 0.42 45 90 Assumed Glassing values 19 Window Left (Southeast) 20.8 0.440 0.26 135 9Q Assumed Glassing values 20 Window Left (Southeast) 20.8 0.440 0.26 135 90 Assumed Glassing values 21 Window Left (Southeast) 108.0 0.380 0.42 135 90 Assumed Glassing values 22 Window Left (Southeast) 108.0 0.380 0.42 135 90 Assumed Glassing values 23 Window Left (South) 80.0 0.380 0.42 180 90 Assumed Glassing values 24 Window Left (South) 80.0 0.380 0.42 180 90 Assumed Glassing values 25 Window Rear (Southwest) 6.0 0.440 0.26 225 90 Assumed Glassing values 26 Window Rear (Southwest) 32.5 0.440 0.26 225 90 Assumed Glassing values 27 Window Rear (Southwest) 6.0 0.440 0.26 225 90 Assumed Glassing values 28 Window Rear (West) 25.2 0.440 0.26 270 90 Assumed Glassing values 29 Window Rear (West) 20.0 0.440 0.26 270 90 Assumed Glassing values INTERIOR AND EXTERIOR SHADING Window Overhang_ Left Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. He 1 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 2 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 3 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 4 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 5 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 6 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0,0 7 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 8 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 9 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 10 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 11 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 12 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 13 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 14 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 15 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 16 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 17 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 18 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 19 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 20 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 21 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 22 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 23 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 24 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 25 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 26 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 27 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 1028 29 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Location/ Comments HVAC -2 HVAC -2 HVAC -2 HVAC -2 HVAC -2 HVAC -2 HVAC -2 HVAC -2 HVAC -2 HVAC -2 HVAC -2 HVAC -2 HVAC -3 HVAC -3 HVAC -3 HVAC -3 HVAC -3 HVAC -3 HVAC -3 HVAC -3 HVAC -3 HVAC -3 HVAC -4 HVAC -4 HVAC -4 HVAC -4 HVAC -4 HVAC -4 HVAC -4 Dist. EnergvPro 3.1 By EnergvSoft User Number: 3665 Job Number: 0004.00 Paae:14 of 53 1 Computer Method Summary (Part 2 of 3) C -2R Horn Residence 1/15/2004 Project Title Date - FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments _3.0. Window_Ero�t (Northeast) _a8A _0_3.8D -0_42. fib_ _9.0 Assumed -Glassing values J•iVAC_5 31 Window Front (Northeast) 3.8 0.440 0.26 45 90 Assumed Glassing values HVAC -5 32 Window Left (Southeast) 29.0 0.440 0.26 135 90 Assumed Glassing values HVAC -5 33 Window Left (Southeast) 120.0 0.380 0.42 135 90 Assumed Glassing values HVAC -5 34 Window Left (Southeast) 22.5 0.380 0.42 135 90 Assumed Glassing values HVAC -5 35 Window Left (Southeast) 22.5 0.380 0.42 135 90 Assumed Glassing values HVAC -5 35 Window Rear (Southwest) 180.0 OMOL 0.42 225 90 Assumed Glassing values HVAC -6 37 Window Rear (Southwest) 120.0 0.380 0.42 225 90 Assumed Glassing values HVAC -6 38 Window Right (Northwest) 11.0 0.440 0.26 315 90 Assumed Glassing values HVAC -7 39 Window Right (Northwest) 22.0 0.440 0.26 315 90 Assumed Glassing values HVAC -7 40 Window Right (Northwest) 11.0 0.440 0.26 315 90 Assumed Glassing values HVAC -7 41 Window Right (Northwest) 6.0 0.440 0.26 315 90 Assumed Glassing values HVAC -7 _4.2 Window-Right_nottbmst) ---6-0- -O-44Q 0.25 315 90 Assumed Glassing values HVAC -7 43 Window Right (Northwest) 6.3 0.440 0.26 315 90 Assumed Glassing values HVAC -7 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 31 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 32 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 33 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 34 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 35 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 00 36 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 37 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 38 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 39 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 40 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 41 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 42 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 43 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Run InitiationTime: 1 l 4 :12:1 Run Code: 1074183130 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: 0004.00 Page: 15 of 53 Computer Method Summary Length (Part 3 of 3) C -2R Insulation R -Val. Depth Location / Comments Slab Perimeter Horn Residence 0.76 0.0 0 HVAC -2 Slab-P-ei imeier 1/15/2004 ANNILProiect Title —0-0 0 HVAC -2 Slab Perimeter 08 Date THERMAL MASS FOR HIGH MASS DESIGN 0 HVAC -3 Slab_P_erimeier 8 . Area Thick. Heat liVgC-3 Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Tile in Mortar _9.64 015 _24 _0_67- N.a 0. HVAC2/ Interio�llass Concrete, Heavyweight 964 4_00 28 0_98 n/a 0 HVAC -2 / Slab on Grade Concrete, Heavyweight 241 4.00 28 0.98 n/a 2 HVAC -2 / Slab on Grade Tile in Mortar 165 0_75 24 0_67 n/a 0 HVAC -3 / Interior Mass C-oJ1cLe1e,_lieaMeiaht 165 4.00 28 0.98 n/a 0 HVAC -3 / Slab on Grade PERIMETER LOSSES Type Length F2 Factor Insulation R -Val. Depth Location / Comments Slab Perimeter 71 0.76 0.0 0 HVAC -2 Slab-P-ei imeier _2.4 -O-Z6 —0-0 0 HVAC -2 Slab Perimeter 08 0.76 0.0 0 HVAC -3 Slab_P_erimeier 8 . 0-Z6 —0-0 0 liVgC-3 Slab-Eetimeter �1 0.76 0.0 0 HVAC -4 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80° AFUE Ducts in Attic 6.0 Setback HVAC -2 Central Furnace 80%AFUE Ducts in Attic 6.0 Setback HVAC -3 Central Furnace 80%AFUE Ducts in Attic 6.0 Setback HVAC -4 Central Furnace 80%AFUE Ducts in Attic 6.0 Setback HVAC -5 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 15.0 EER Ducts in Attic 6.0 Setback HVAC -2 Split Air Conditioner 15.0 SEER Ducts in Attic 6.0 Setback HVAC -3 Split Air Conditioner 15.0 SEER Ducts in Attic 6.0 Setback HVAC -4 Split Air Conditioner 15.0 SEER Ducts in Attic 6.0 Setback HVAC -5 WATER HEATING SYSTEMS Rated' Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. Standard Gas 50 gal. Small Gas Recirc/Time+Temp 1_ 40,000 50 0.58 n/a n/a Standard Gas 75 gal. Small Gas Recirc/Time+Temp 1 40.000 75 0.58 n/a n/a Standard Gas 50 gal. Small Gas Recirc/fime+Temp 1 40.000 50 0.58 n/a n/a • For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 01115/0408:12:10 Run Code: 1074183130 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 16 of 53 Computer Method Summary Length (Part 3 of 3) C -2R Insulation R -Val. Depth Location / Comments Slab Perimeter Horn Residence 0.76 2Q 0 HVAC -4 1/15/2004 AdilkProiect Title 026 O -Q 0 IiVAG_5 Date THERMAL MASS FOR HIGH MASS DESIGN 0.76 0.0 0 Area Thick. Heat O26 Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete Heavyweight 6-6.3 4M --28_ 0 -Ra n/a —2 ± AC_3LS1ab�n-Glade Tile in Mortar 698 0_75 24 0_67 n/a 0 HVAC -4 / Interior Mass Concre e Heavyweight— 698 -4-00 --211 0.-M n/a 0 HVAC -4 / Slab on Grade Concrete, Heavyweight 1.046 4_00 28 0_98 n/a 2 HVAC -4 / Slab on Grade IiLe_j0A0ttar 1.359 0.75 24 0.67 n/a 0 HVAC -5 / Interior Mass PERIMETER LOSSES Type Length F2 Factor Insulation R -Val. Depth Location / Comments Slab Perimeter 86 0.76 2Q 0 HVAC -4 Slab_2ehmeter —_QQ 026 O -Q 0 IiVAG_5 Slab Perimeter 1 0.76 0.0 0 HVAC -5 Sl.ab-P-edmeter 77_ O26 _O..Q Q HVA�6 Slab-P-erimeter 22 0.76 0.0 0 HVAC -6 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Split Air Conditioner Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments -C n_tral Furnace 80° AFUE Ducts in Attic 6.0 Setback HVAC -6 Central Furnace 80%AFUE Ducts in Attic 6.0 Setback HVAC -7 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Type (air conditioner, heat pump, evap. cooling) Minimum Duct Efficiency Location Duct Thermostat (SEER) (attic, etc,) R -Value Type Location / Comments Split Air Conditioner 15.0 SEE Ducts in Attic 6.0 Setback HVAC -6 Split Air Conditioner 16.0 SEER Ducts in Attic 6.0 Setback HVAC -7 WATER HEATING SYSTEMS Ratedl Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. 0 Computer Method Summary (Part 3 of 3) C -2R Horn Residence Heating Equipment Minimum 1/15/2004 -Project Title Type (furnace, heat Efficiencyy Date THERMAL MASS FOR HIGH MASS DESIGN Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heavyweight X35.9 _4_0_0 28. 0_9$ nLa 0 ±LVAC.5_L la�oo G.rade Concrete, Heavyweight 239 4_00 28 0_98 n/a 2 HVAC -5 / Slab on Grade Tile in _lQrtar 941 0.75 24 0.67 n/a 0 HVAC -6 / Interior Mass Concrete, Heavyweight 941 4_00 28 0_98 n/a 0 HVAC -6 / Slab on Grade Caacr_eie Heaxyxve.igli.t 95 4.00 28 0.98 n/a 2 HVAC -6 / Slab on Grade PERIMETER LOSSES Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 60 0.76 0.0 2 HVAC -7 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiencyy and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS Energy Fact! 1 Tank Insul. Ratedl Tank Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. • 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 01/15/0408:12:10 Run Code: 1074183130 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:18 of 53 Coinputer Method Summary (Part 3 of 3) C -2R Horn Residence 1/15/2004 -Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments on rete, Heavyweight —627 00 _28_ _0_98. n/a 2. 1iVAC� /_S1atZo>LGtade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments • Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS Rated' Tank Energy Facts Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Cj Run Initiation Time: 01/15/0408:12:10 Run Code: 1074183130 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 19 of 53 Computer Method Summary (Addendum) C -2R Horn Residence 1/15/2004 -Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field 0 • The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -2" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -2" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 964 sqft Tile in Mortar Interior Mass, 0.75' thick at First Floor HIGH MASS Design(see C -2R) - Verify Thermal Mass: 964 sqft Exposed Slab Floor, 4.00" thick at First Floor HIGH MASS Design(see C -2R) - Verify Thermal Mass: 241 sqft Covered Slab Floor, 4.00" thick at First Floor The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -3" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -3" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 165 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 165 sqft Exposed Slab Floor, 4.00" thick at HVAC -3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. I Plan I Field The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -4" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -5" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:20 of 53 1 Computer Method Summary (Addendum) C -2R Horn Residence 1/15/2004 -Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field • HIGH MASS Design(see C -2R) - Verify Thermal Mass: 663 sqft Covered Slab Floor, 4.00" thick at HVAC -3 The HVAC System "HVAC -4" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -4" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -4" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -4" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 698 sqft Tile in Mortar Interior Mass, 0.75" thick at HVAC -4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 698 sqft Exposed Slab Floor, 4.00" thick at HVAC -4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1046 sqft Covered Slab Floor, 4.00" thick at HVAC -4 The HVAC System "HVAC -5" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -5" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -5" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -5" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1359 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -5 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. I Plan I Field The HVAC System "HVAC -5" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -6" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -6" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -7" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -7" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 01/15/0408:12:10 Run Code: 1074183130 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:21 of 53 Computer Method Summary (Addendum) C -2R Horn Residence 1/15/2004 -Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field • HIGH MASS Design(see C -21R) - Verify Thermal Mass: 1359 sqft Exposed Slab Floor, 4.00" thick at HVAC -5 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 239 sqft Covered Slab Floor, 4.00" thick at HVAC -5 The HVAC System "HVAC -6" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -6" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -6" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -6" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 941 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -6 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 941 sqft Exposed Slab Floor, 4.00" thick at HVAC -6 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 95 sqft Covered Slab Floor, 4.00" thick at HVAC -6 The HVAC System "HVAC -7" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -7" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -7" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -7" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field Run Initiation Time: 01/15/0408:12:10 Run Code: 1074183130 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:22 of 53 Catnputer Method Summary (Addendum) C-2R Horn Residence 1/15/2004 AftProject Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )asea on the aaequacy or the speciai fustirication ana aocumentation supmittea. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 627 sgft Covered Slab Floor, 4.00" thick at HVAC -7 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field • • MWM EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 23 of 53 1 • PROPOSED CONSTRUCTION ASSEMBLY ENV -3 NAME Horn Residence DATE 1/15/2004 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 2 Stucco Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, Loose Fill 5 Gypsum or Plaster Board 6 ASSEMBLY NAME R-23 Certint blown in Wall 0.31 8 0.37 9 2.60 ASSEMBLY Floor 0.6801 0.680 23.01 TYPE (check one) X Wall 0 LLI Ceiling I Roof F Q in FRAMING MATERIAL Wood p Z FRAMING % 15 % Framing 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 2 Stucco Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, Loose Fill 5 Gypsum or Plaster Board 6 0.5621 7 0.31 8 0.37 9 2.60 0.26 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.1751 0.175 0.060 0.060 0.465 0.465 20.900 5.445 0.5621 0.562 0.31 2.63 0.37 0.98 2.60 0.26 0.68 0.6801 0.680 23.01 7.56 RG RT 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0435 X 0.85 ] 8.46 0.20 1.69 0.06 0.35 0.02 1.06 0.29 0.31 2.63 0.37 0.98 2.60 0.26 0.68 14.8 TOTAL HC 3 7 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0435 X 0.85 ] + [ 0.1323 X L 0.15 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE I EnergvPro 3.1 By EnergvSoft User Number: 3665 Job Number: 0004.00 Page:24 of 53 1 • PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME Horn Residence DATE 1/15/2004 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Insulation, Mineral Fiber, Loose Fill 3 Gypsum or Plaster Board 4 0.37 5 ASSEMBLY NAME R-23 Certin blown in Wall -2 7 1 - (Fr% / 100) 8 Fr% / 100 ASSEMBLY Floor INSIDE SURFACE AIR FILM 0.680 23.60 TYPE (check one) X Wall a 0 /Roof H Ceiling FRAMING MATERIAL yyo� p N Z FRAMING % 15 % Framing 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) THICK- NESS (in.) 0-3-75- 5.750 .3755.750 0.625 SUBTOTAL R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Insulation, Mineral Fiber, Loose Fill 3 Gypsum or Plaster Board 4 0.37 5 2.60 6 0.68 7 1 - (Fr% / 100) 8 Fr% / 100 9 INSIDE SURFACE AIR FILM THICK- NESS (in.) 0-3-75- 5.750 .3755.750 0.625 SUBTOTAL R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.3371 0.337 21.850 5.693 0.562 0.562 0.37 1.02 2.60 0.26 0.68 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE 0.6801 0.680 23.60 7.44 KC KT *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 1.56 0.26 0.41 2.751 0.37 1.02 2.60 0.26 0.68 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE 6 9 TOTAL HC 2 1 NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. I0.0424 X 0.85 ] + [ 0.1344 XL 0.15 ] 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE I EnergvPro 3.1 By EnerovSoft User Number: 3665 Job Number. 0004.00 Page:25 of 53 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Horn Residence SYSTEM NAME I HVAC -2 Number of Systems 1 Heating System Output per System 90,000 Total Output (Btuh) 90,000 Output (Btuh/sqft) 62.3 Cooling System Output per System 60,000 Total Output (Btuh) 60,000 Total Output (Tons) 5.0 Total Output (Btuh/sqft) 41.6 Total Output (sgft/Ton) 288,8 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sqft) 1.39 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 1/15/2004 FLOOR AREA 1.444 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 1,414 25,947 7,90 667 25,196 0 1,297 1,260 0 0 0 0 0 0 0 0 0 1,297 1,260 28 542 7 90 27 716 HSX19-060/G60UHV-60C-110X (5) 40,574 9,581 90,000 Total Adjusted System Output40,574 9,581 90,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am ((-(EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) I 24.0 of 69.4 of 105.0 of 105.0 of O Supply Air Ducts Outside Air 0 cfm Heating Coil Supply Fan 104.4 of 2000 cfm ROOMS 70.0 OF 69.4 of K Return Air Ducts `S (COOLING SYSTEM PSYCHROMETRICS (Airstream Temoeratures at Time of Coolina Peak) I 114.1 / 80.3 of Outside Air 0 cfm 72.6/61.9 of 72.6/61.9 OF . 55.0/54.0 OF Cooling Coil Supply Fa 2000 cfm 55.0 / 54.0 of Supply Air Ducts Fan 55.6/54 . 2 of 56.0% R.H. ROOMS 72.0 / 61.7 of >% Return Air Ducts `i EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: 0004.00 Page 26 of 53 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Horn Residence 1/15/2004 SYSTEM NAME FLOOR AREA HVAC -3 828 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 90,000 Total Output (Btuh) 90,000 Output (Btuh/sgft) 108.7 Cooling System Output per System 60,000 Total Output (Btuh) 60,000 Total Output (Tons) 5.0 Total Output (Btuh/sqft) 72.5 Total Output (sgft/Ton) 165.6 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sqft) 2.42 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 11COILHTG.PEAK CFM I Sensib I CFM I Sensible 2,196 40,302 6,782 717 27,088 0 2,015 1,354 0 0 0 0 0 0 0 0 0 2,015 11354 44 332 6,782 29 797 HSX19-060/G60UHV-60C-110X (5) 41,435 8,639 90,000 Total Adjusted System Output 41,435 8,639 90,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Note: values above given at ARI conditions IL- JEATING SYSTEM PSYCHROMETRICS (Airstream Tel 24.0 of 69.4 of . 105.0 of Outside Air 0 cfm Heating Coil 69.4 OF Supply Fan 2000 cfm 105.0 of —� Supply Air Ducts 104.4 of ROOMS 70.0 of K Return Air Ducts `{ (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I 114.1 / 80.3 of Outside Air 0 cfm 72.9/61.8 of ec 72.9/61.8OF. 55.0/53.9OF Cooling Coil Supply Fa 2000 cfm 55.0 / 53.9 of Supply Air Ducts Fan �% Return Air Ducts 4 55.9/54 . 3 of 55.2% R.H. ROOMS 72.0 / 61.5 of EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page. 27 of 53 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE . Horn Residence 1/15/2004 •SYSTEM NAME FLOOR AREA HVAC -4 1,744 Number of Systems 1 Heating System Output per System 90,000 Total Output (Btuh) 90,000 Output (Btuh/sqft) 51.6 Cooling System Output per System 60,000 Total Output (Btuh) 60,000 Total Output (Tons) 5.0 Total Output (Btuh/sqft) 34.4 Total Output (sgft/Ton) 348.8 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.15 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) —r--0.00 Note: values above aiven at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 1,746 32,039 1 0,527 760 28,710 0 1,602 1,435 0 0 0 0 0 0 0 0 0 1,602 1,435 35,243 10,527 31,581 HSX19-060/G60UHV-60C-110X (5) 39,786 10,770 90,000 Total Adjusted System Output 39,786 10,770 90,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 'ING SYSTEM PSYCHROMETRICS (Airstream Tem 24.0 of 69.3 of . 105.0 of Outside Air 0 cfm 69.3 of 14.1 / 80.3 of Outside Air 0 cfm 72.7/62.4 0 F Heating Coil at Time of Supply Fan 2000 cfm 105.0 of Supply Air Ducts 104.3 of ROOMS 70.0 of �% Return Air Ducts `{ 72.7 / 62.4 of . 55.0 / 54.0 of Cooling Coil Supply Fa 2000 cfm 55.0 / 54.0 of Supply Air Ducts Fan 55.7/54.3OF 57.7% R.H. ROOMS 72.0 / 62.1 of 01 Return Air Ducts I Ener4vPro 3.1 By EnerovSoft User Number: 3665 Job Number: 0004.00 Paae:28 of 53 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Horn Residence 1/15/2004 •SYSTEM NAME FLOOR AREA HVAC -5 1,598 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 90,000 Total Output (Btuh) 90,000 Output (Btuh/sgft) 56.3 Cooling System Output per System 60,000 Total Output (Btuh) 60,000 Total Output (Tons) 5.0 Total Output (Btuh/sgft) 37.5 Total Output (sgftrron) 319.6 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.25 Airflow (cfmrron) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 24.0 of 69.3 of I J Outside Air 0 cfm 69.3 of 114.1 / 80.3 of Outside Air 0 cfm 72.8/62.4 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensible Latent CFM I Sensible 1,974 36,220 10,687 818 30,909 0 1,811 1,545 0 0 0 0 0 0 0 0 0 1,811 1,545 39,842 10 687 HSX19-060/G60UHV-60C-110X (5) 39,857 10,744 Total Adjusted System Output 39,857 10,744 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm yam Tem 105.0 of Heating Coil Time of H -�@J Supply Fan 2000 cfm 90,000 90,000 Jan 12 am 105.0 OF Supply Air Ducts 104.3 of ROOMS 70.0 of k Return Air Ducts 4 72.8 / 62.4 OF . 55.0 / 54.0 of Cooling Coil Supply Fa 2000 cfm 55.0 / 54.0 of Supply Air Ducts Fan 55.8 / 54.4 of 57.8% R.H. ROOMS 72.0 / 62.2 of h Return Air Ducts "I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. 0004.00 Page: 29 of 53 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Horn Residence 1/15/2004 is SYSTEM NAME FLOOR AREA HVAC -6 1,036 Number of Systems 1 Heating System Output per System 90,000 Total Output (Btuh) 90,000 Output (Btuh/sgft) 86.9 Cooling System Output per System 60,000 Total Output (Btuh) 60,000 Total Output (Tons) 5.0 Total Output (Btuh/sgft) 57.9 Total Output (sgft/ron) 207.2 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.93 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I I CFM I Sensible 1,508 27,671 5,787 570 21,553 0 1,384 1,078 0 0 0 0 0 0 0 0 0 1,384 1,078 30,438 5 787 HSX19-060/G60UHV-60C-110X (5) 41,421 8,447 Total Adjusted System Output 41,421 8,447 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatina Peak) 24.0 of Outside Air 0 cfm 69.5 of 114.1 / 80.3 of Outside Air 0 cfm 72.6/61.5 of 69.5 of E 105.0 of Heating Coil 90,000 90,000 Jan 12 am 105.0 of O Supply Air Ducts Supply Fan 104.5 of 2000 cfm ROOMS 70.0 of Return Air Ducts I 72.6/61.5OF 55.0/53.9OF 0 Cooling Coil Supply Fa 2000 cfm 55.0 / 53.9 of Supply Air Ducts Fan K Return Air Ducts 11 55.6/54 . 2 of 54.5% R.H. ROOMS 72.0 / 61.3 of EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: 0004.00 Page:30 of 53 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Horn Residence 1/15/2004 SYSTEM NAME FLOOR AREA HVAC -7 627 Number of Systems 1 Heating System Output per System 54,000 Total Output (Btuh) 54,000 Output (Btuh/sqft) 86.1 Cooling System Output per System 35,600 Total Output (Btuh) 35,600 Total Output (Tons) 3.0 Total Output (Btuh/sqft) 56.8 Total Output (sgft/Ton) 211.3 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sqft) 1.91 Airflow (cfmfron) 404.5 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 1COILHTG.PEAK CFM ISensibleF Latent 1CFM1 Sensible 643 11,801 3,879 330 12,485 0 590 624 0 0 0 0 0 0 0 0 0 590 1 624 12,98 3,879 13 734 HSX19-036/G60UHV-36A-070X (3) 24,181 5,438 54,000 Total Adjusted System Output24,181 5,438 54,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 1EATING SYSTEM PSYCHROMETRICS (Airstream Tel 24.0 OF 69.5 OF . 105.0 OF Outside Air 0 cfm 69.5 of 114.1/80.30F Outside Air 0 cfm 72.5/61.6 of Heating Coil lei Supply Fan 1200 cfm 105.0 of Supply Air Ducts 104.5 of ROOMS 70.0 of K Return Air Ducts 4 72.5 / 61.6 of 55.0 / 54.0 of Cooling Coil Supply Fa 1200 cfm 55.0 / 54.0 of Supply Air Ducts Fan 55.5/54.2OF 55.0% R.H. ROOMS 72.0 / 61.4 of �, Return Air Ducts '� EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page :31 of 53 • ROOM LOAD SUMMARY PROJECT NAME Horn Residence DATE 1/15/2004 SYSTEM NAME HVAC -2 FLOOR AREA 1,444 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -2 First Floor 1 1,155 21,204 6,851 1,155 21,204 6,851 566 21,379 HVAC -2 Second Floor (Tower) 1 19 343 159 19 343 159 7 280 HVAC -2 Third Floor (Tower) 1 240 1 4,400 891 240 1 4,400 8911 94 1 3.538 PAGE TOTAL 1 1,414 25,947 7,901 667 25,196 TOTAL 1 1,414 25,947 7,901 667 25,196 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:32 of 53 E E ROOM LOAD SUMMARY ::1 PROJECT NAME Horn Residence DATE 1/15/2004 SYSTEM NAME HVAC -3 FLOOR AREA 828 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -3 HVAC -3 1 2,196 40,302 6,782 2,196 40,302 6,782 717 27,088 PAGE TOTAL 1 2,196 40,302 6,782 717 27,088 TOTAL 1 2,196 40,302 6,782 717 27,088 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 33 of 53 48 • ROOM LOAD SUMMARY :1 PROJECT NAME Horn Residence DATE 1/15/2004 SYSTEM NAME HVAC -4 FLOOR AREA 1,744 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -4 HVAC -4 1 1,746 32,039 10,527 1,746 32,039 10,527 760 28,710 i r PAGE TOTAL 1 1,746 32,039 10,527 760 28,710 TOTAL 1 1,746 32,039 10,527 760 28,710 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 34 of 53 0 L-1 ROOM LOAD SUMMARY PROJECT NAME Horn Residence DATE 1/15/2004 SYSTEM NAME HVAC -5 FLOOR AREA 1,598 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -5 HVAC -5 1 1,974 36,220 10,687 1,974 36,220 10,687 818 30,909 PAGE TOTAL 1 1,974 36,220 10,687 818 30,909 TOTAL 1 1,974 36,220 10,687 818 30,909 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 35 of 53 a 17, GO ROOM LOAD SUMMARY PROJECT NAME Horn Residence DATE 1/15/2004 SYSTEM NAME HVAC -6 FLOOR AREA 1,036 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -6 HVAC -6 1 1,508 27,671 5,787 1,508 27,671 5,787 570 21,553 PAGE TOTAL 1 1,508 27,671 5,787 570 21,553 TOTAL 1 1,508 27,671 5,787 570 21,553 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. 0004.00 Page:36 of 53 1.1 0 ROOM LOAD SUMMARY PROJECT NAME Horn Residence DATE 1/15/2004 SYSTEM NAME HVAC -7 FLOOR AREA 627 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -7 HVAC -7 1 643 11,801 3,879 643 11,801 3,879 330 12,485 PAGE TOTAL 1 643 11,801 3,879 330 12,485 TOTAL 1 643 11,801 3,879 330 12,485 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 37 of 53 Ak • ROOM HEATING PEAK LOADS Project Title Date Horn Residence 1/15/2004 Room Information Desicin Conditions Room Name First Floor Time of Peak Jan 12 am Floor Area 1,205 Outdoor Dry Bulb Temperature 24OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr values 38.0 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0341 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0 = = = = = = = = = = = = = = = = = = = = = = = = 0 1,167.0 0.0275 46.0 1,474 593.5 0.0568 46.0 1,550 106.5 0.4400 46.0 2,156 48.0 0.3872 46.0 855 346.0 0.0644 46.0 1,025 perimeter = 95.5 45.5 4,345 items snown wan an astensK (-rr) denote conduction tnrougn an interior surrace to anotner room. Page Total: 11,406 Infiltration: I 1.00 x 1.080 x 1 205 x 10.00 x 6] x 46 = 9 973 —Schedule Air Sensible Area Ceiling Height ACH OT Fraction • TOTAL HOURLY HEAT LOSS FOR ROOM 21,379 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 38 of 53 AK w ROOM HEATING PEAK LOADS Project Title Date Horn Residence 11/15/2004 Room Information Desicin Conditions Room Name Second Floor (Tower) Time of Peak Jan 12 am Floor Area 38 Outdoor Dry Bulb Temperature 24OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr 38.0 X x x X X x x x x X x x X x x X X X x x x x x x x x x x x x x x x x x x x x x 0.0341 X X x x X x X x X x x X x x x x X X x x x x x x x x x x x x x x x x x x x x x 0.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 0 38.0 0.0341 46.0 60 items shown With an astenSK (`j denote conduction through an interior surface to another room. rr Page Total: 1 so Infiltration: II 1.001X 1.080 x 38 x 7.00 x 1.00 / 60] x 46 = 220 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 39 of 53 280 AK w ROOM HEATING PEAK LOADS Project Title Date Horn Residence 1/15/2004 Room Information Desicin Conditions Room Name Third Floor (Tower) Time of Peak Jan 12 am Floor Area 201 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total Infiltration: L 1.001 x 1.080 x 201 x 7.50 x 6] x 46 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 254 870 850 316 2 290 = 1248 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 40 of 53 201.0 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0275 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 333.2 0.0568 46.0 42.0 0.4400 46.0 201.0 0.0341 46.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total Infiltration: L 1.001 x 1.080 x 201 x 7.50 x 6] x 46 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 254 870 850 316 2 290 = 1248 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 40 of 53 9 ROOM HEATING PEAK LOADS Project Title Date Horn Residence 1/15/2004 Room Information Desion Conditions Room Name ' HVAC -3 Time of Peak Jan 12 am Floor Area 828 Outdoor Dry Bulb Temperature 24OF Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr Assumed 828.0 392.0 602.4 41.6 perimeter = 74.0 0.0275 0.0568 0.3800 0.4400 Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Infiltration: 1.001X 1.080 x 828 x 15.00 x 1.00 / 60] x chedule Air Sensible Area Ceiling Height ACH Fraction 46.0 46.0 46.0 46.0 45.5 1,046 1,024 10,530 842 3,367 Page Total: I 16,8091 46 = 10 280 DT TOTAL HOURLY HEAT LOSS FOR ROOM 27 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page:41 of 53 • ROOM HEATING PEAK LOADS Project Title Date Horn Residence 1/15/2004 Room Information Design Conditions Room Name HVAC -4 Time of Peak Jan 12 am Floor Area 1,744 Outdoor Dry Bulb Temperature 24°F Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 13 265 Infiltration: 1 1.00 x 1.080 x 1 744 x 10.70 x 6] x 46 = 15445 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 28.710 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. 0004.00 Page: 42 of 53 1,744.0 x x X x X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0275 x X X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 2,203 334.0 0.0644 46.0 990 409.3 0.0568 46.0 1,069 160.0 0.3800 46.0 2,797 89.7 0.4400 46.0 1,816 perimeter = 96.5 45.5 4,391 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 13 265 Infiltration: 1 1.00 x 1.080 x 1 744 x 10.70 x 6] x 46 = 15445 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 28.710 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. 0004.00 Page: 42 of 53 ROOM HEATING PEAK LOADS 1 Project Title Date Horn Residence 1/15/2004 Room Information Des! - n Conditions Room Name HVAC -5 Time of Peak Jan 12 am Floor Area 1,598 Outdoor Dry Bulb Temperature 24 of Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr A 1,598.0 x x X x x X X x X x x X x x X X x x X X x X X x x x x X X X X X X X X X X Xx X 0.0275 X x x x x X X X X X X X X X X X X x X X x X X x X X X X x X X x X x X X x X 46.0 = = = = = = = = = = = = = = = = = 2,018 1,112.2 0.0568 46.0 2,905 253.0 0.3800 46.0 4,422 32.8 0.4400 46.0 664 perimeter = 110.5 45.5 5,028 P Items shown with an asterisk (•rr) denote conduction through an interior surface to another room. Page Total: 15 038 Infiltration: I1.00 x 1.080 x 1 598 x 12.00 x 1.00 / 60] x 46 = 15 871 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 43 of 53 • ROOM HEATING PEAK LOADS Project Title Date Horn Residence 11/15/2004 Room Information Desi - n Conditions Room Name HVAC -6 Time of Peak Jan 12 am Floor Area 1,036 Outdoor Dry Bulb Temperature 24 of Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 13 150 Infiltration: I rrx 1.080 x 1 036 x 9.80 x 6] x 46 = 8 403 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 21.553 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 44 of 53 1036.0 X x X x X x X x X X x X X X x x X X x x X X X X X x X X X X x x x X X X X X x 0.0275 x X x x x X x x X X X X x X X x X x X x x X x X X X X x x x x x x X X x X x x 46.0 = = = = = = = = = = = = = = = = = = = 1,309 765.0 0.0568 46.0 1,998 32.0 0.0644 46.0 95 300.0 0.3800 46.0 5,244 perimeter = 99.0 45.5 4,504 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 13 150 Infiltration: I rrx 1.080 x 1 036 x 9.80 x 6] x 46 = 8 403 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 21.553 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 44 of 53 ROOM HEATING PEAK LOADS Project Title Date Horn Residence 1/15/2004 Room Information Desicin Conditions Room Name HVAC -7 Time of Peak Jan 12 am Floor Area 627 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr Wood Door 627.0 x x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0275 x x X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 792 599.7 0.0568 46.0 1,566 62.3 0.4400 46.0 1,261 24.0 0.3872 46.0 427 perimeter = 60.0 45.5 2.730 Items shown with an asterisk (`r) denote conduction through an interior surface to another room. Page Total: 6 777 Infiltration: 1.00 x 1.080 x 627 x 11.00 x 6] x 46 = 5 708 hedule Air Sensible Area Ceiling Height ACH AT Fraction EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 45 of 53 • 0 fZESIDENTIAL ROOM COOLING LOAD SUMMARY Horn Residence 1/15/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area 167 106. U -Value X 0.034' X 0.0275 X 0.0568 X 0.4400 X 0.3872 X 0.0644 X 41.6 x 174 X 1 First Floor 72°F 115°F 430F X X X X X X DETD 1 = = = = = = Btu/hr 0.0 0 62.0 1,987 41.6 1,402 43.0 2,015 41.6 773 41.6 927 X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 7 104 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr CsmntWdw (E2) (North) FxdG1s1N_dmL(.F_4.) CsmntWdw E1 (Northeast) CsmntWdw F1 _(Northeast) (Northeast) CsmntWdw (F2) (Northeast) CsmntWdw F3 (Northeast) CsmntWdw E3 (East) CsmntWdw D (East) 48) 0.289 174 ( 0.0 ( 0.0 x1 X x x X X x x x x + + + + + + + + + + 3.0 x x x X X X x x X x 15) X x x x X )x )x 0.289 = = = = = = = = = = 13 ( 0.0 1 12.5 48) 0.289 174 ( 0.0 1 3.0 48)X 0.289 42 ( 0.0 1 7.5 48) 0.289 104 ( 0.0 1 25.0 48) 0.289 347 ( 0.0 1 7.5 48) 0.289 104 ( 0.0 1 3.0 73)X 0.289 63 ( 0.0 1 45.0 73)X 0.289 951 ( ( Sched. Page Total 1 7ss Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,205 x 0.500 Watts/sqft x 3.41 BtuhlWatt = 2,056 Occupants 1.00 X 1,205 X 255 Btuh/occ. / 333 sgft/occ. = 923 Receptacle 1.00 x 1,205 x 0.000 Watts/sqft x 3.413 BtuhlWatt = 0 Process 1.00 x 1,205 x 0.000 18 Watts�/sgftx 3.413 Btuhh[VVatt = 0 Infiltration: �C�� x 1=17y8 x 205 x 0_QO x [ 1.0t01 / 60] �43J =9_32.3 Schedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,204 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 1 205 x 225 Btuh/occ. / 333 sgft/occ. = 814 Receptacle 1.00 X 1 205 x 0.000 Watts/sgft X 3.41 BtuhfWatt = 0 Process 1.00 X 1 205 x 0.000 Wafts/sqft X 3.41 Btuh/Waft = o Infiltration: 1.00x 4 840 x 1 205 x 10.00 x 1.00 / 60] 0.00621 = 6 037 chedule Alr Latent Area Ceiling Height ACH Z -\W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,851 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 46 of 53 ,RESIDENTIAL ROOM COOLING LOAD SUMMARY Horn Residence 1/15/2004 Project Tide Date • Room Name Second Floor (Tower) is • Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: 72°F 115°F 43°F Conduction Area U -Value DETD 1 Btu/hr X 0.0 = 0 X 33.0 = 43 X = X = X = X = X = X = X = 1. Design Equivalent Temperature Difference (DETD) Page Total 43 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = Sched. Page Total 0 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 38 x 0.500 Watts/sgft x 3.412 Btuh/Waft = 65 Occupants 1.00 x 38 x 255 Btuh/occ. / 333 sgft/occ. = 29 Receptacle 1.00 x 38 x 0.000 Watts/sgft x 3.413 BtuhlWatt = 0 Process 1.00 x 38 x 0.000 Wafts/sgft x 3.412 Btuh/Waft = o Infiltration: E1.00 x1.oso x x oD x =11J / 60] =3 = Q6 Schedule Air Sensible Area Ceiling Height ACH nT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 343 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 38 x 225 Btuh/occ. / 333 sgft/occ. = 26 Receptacle 1.00 x 38 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = 0 Process I� 1.00 x 38 x 0.000 Wafts/sqft x 3.41 Btuh/Waft = o Infiltration:I 1.00 x 4 840 x �3 x 7.00 x 1.00 / 60] 0.00621 = 133 "`Schedule Air Latent Area Ceiling Height ACH Z -\W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 159 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 47 of 53 E • RESIDENTIAL ROOM COOLING LOAD SUMMARY Horn Residence 1/15/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value 201 Third Floor (Tower) 720F 115°F 430E DETD 1 x 62.0 x 41.6 x 43.0 x 33.0 x x x x x Btu/hr 342 787 795 226 1. Design Equivalent Temperature Difference (DETD) Page Total 2 150 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr CsmntWdw S4 -(North) ( 0.0 x 1 + 10.5 X 15 ) X 0.289 = 46 CsmntWdw (East) ( 0.0 x 1 + 10.5 X 73 )x 0.289 = 222 CsmntWdw S2 (South) ( 0.0 x 1 + 10.5 x 32)X 0.289 = 97 CsmntWdw S3 _(West) ( 0.0 x 1 + 10.5 X 73)x 0.289 = 222 ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + X )x = Sched. Page Total 587 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 201 X 0.500 Watts/sgft x 3.413 Btuh/Waft = 343 Occupants 1.00 X 201 X 255 Btuh/occ. / 333 sqft/occ. = 154 Receptacle 1.00 x 201 X 0.000 Wafts/sqft X 3.413 Btuh/Waft = 0 Process 1.00 x 201 x X�0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: OA x 1.080 x x I7-5DJ x1.00 / 60� = 1,166 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 4,400 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 201 X 225 Btuhlocc. / 333 sqft/occ. = 136 Receptacle 1.00 x 201 x 0.000 Watts/sgft X 3.41 Btuh/Waft = 0 Process 1.00 x 201 x 0.000 Wafts/sqft x 3.a1 Btuh/Waft = o Infiltration: 1.00 x 4840 x 20 x Height x 60] 0.00621 = 755 chedule Air Latent Area Ceiling Height ACH DW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 891 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 48 of 53 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Horn Residence 1/15/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Roof Area U -Value X 0. HVAC -3 72°F 115°F 43°F X X X X X X X X X DETD 1 = = = = = _ = = - Btu/hr 62.0 1,410 41.6 926 43.0 9,843 43.0 787 FxdGlsWdw Q4 (Southeast) FxdGlsWdw Q5 (Southeast) SIdgGIsDr 51) (Southeast) Sld GlsDr 52 Southeast 48) 0.468 1. Design Equivalent Temperature Difference (DETD) Page Total 12 966 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF . SC Btu/hr FxdGlsWdw (Q1) (Northeast) dGtsWdw( (Northeast) FxdGlsWdw Q3 (Northeast) Sld GIsDr (47) (Northeast) SIdgGIsDr (48) (Northeast) Sid GIsDr 49 (Northeast) FxdGlsWdw Q4 (Southeast) FxdGlsWdw Q5 (Southeast) SIdgGIsDr 51) (Southeast) Sld GlsDr 52 Southeast ( 0.0 x x x x X X x x X X 1 + + + + + + + + + + 20.8 X x X X x X x x X x 48 ) X )x X x x x x ) x 0.468 = = = = = = = = = = 467 ( 0.0 1 20.8 48 0.468 467 ( 0.0 1 20.8 48) 0.468 467 ( 0.0 1 108.0 48) 0.468 2,424 ( 0.0 1 108.0 48) 0.468 2,424 ( 0.0 1 108.0 48)X 0.468 2,424 ( 0.0 1 20.8 62)X 0.289 373 ( 0.0 1 20.8 62) 0.289 373 ( 0.0 1 108.0 62) 0.468 3,131 ( "I 1 108.0 62 0.468 3,131 Sched. Page Total 15 s8o Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 828 X 0.500 Watts/sgft x 3.41 BtuhNVaft = 1,413 Occupants 1.00 X 828 X 255 Btuh/occ. / 333 sgft/occ. = 634 Receptacle 1.00 x 828 x 0.000 Wafts/sgft X 3.413 Btuh/Waft = 0 Process �1.00�X X828 X X0.00000 Wafts/sqft X 3.41�Btuhh Watt = 0 Infiltration: [ 00 x I 1.0001 x [ 281 x L_1.5 a x / 60] 1�.3J = 9 do Schedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 40 302 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 828 X 225 Btuh/occ. / 333 sgft/occ. = 559 Receptacle 1.00 x 828 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = o Process 1.00 x 828 x 0.000 Wafts/sqft x 3.41 Btuh/Waft = o Infiltration: 1 1.00 111111 X 4,8401 x 828 X 15.00 X 1.00 / 60] 0.00621 = 6 222 chedule Alr Latent Area Ceiling Height ACH �yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,782 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 49 of 53 • 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Horn Residence 1/15/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value 1.744.4 X DETD 1 62.0 41.6 41.6 43.0 43.0 HVAC -4 720F 115°F 430E Btu/hr - 2,969 895 967 2,614 1.6 7 1. Design Equivalent Temperature Difference (DETD) Page Total 9 143 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Sid GIsDr 54 (South) S1dgGhDr (55.) (South) CsmntWdw M1 (Southwest) FxdGlsWdw M2 _(Southwest) CsmntWdw (M3) (Southwest) CsmntWdw N1 (West) CsmntWdw N2 (West) 32)x 0.468 1,197 ( 0.0 1 6.0 ( 0.0 X x x x X X x x x x 1 + + + + + + + + + 80.0 x x x x x x X x x)X x 32) X )x )x 0.468 = = = = = = = = = 1,197 ( 0.0 1 80.0 32)x 0.468 1,197 ( 0.0 1 6.0 62)x 0.289 108 ( 0.0 15 32.5 62)x 0.289 583 ( 0.0 1 6.0 62)x 0.289 108 ( 0.0 1 25.2 73)X 0.289 532 ( 0.0 1 20.0 73)x 0.289 423 ( ( ( Sched. Page Total 4 147 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,744 x 0.500 Watts/sgft x 3.412 Btuh/Waft = 2,976 Occupants 1.00 X 1,744 X 255 Btuh/occ. / 333 sgft/occ. = 1,335 Receptacle 1.00 x 1,744 x 0.000 Wafts/sgft X 3.413 Btuh/Watt = 0 Process 1.00 X 1,744 x X�0.000 Wafts/sgft x 3.412 Btuh/Watt = o Infiltration: �= x x 1,244 x [=- oz xQo / 60] = 1;:;;8 Schedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 32,039 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occu ants1.00 x 1 744 x 225 Btuh/occ. / 333 sgft/occ. = 1 178 Receptacle 1.00 x 1 744 x 0.000 Watts/sqft x 3.41 Btuh/Waft = o Process 1.00 X 1 744 x 0.000 Wafts/sgft X 3.41 BtuhMaft = o Infiltration: �chedulle x Air Latent t0 X Area 744 X Ceiling Height x ACH 00 / 60] -\V0o621 = 9349 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 10,527 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. 0004.00 Page: 50 of 53 0 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Horn Residence 1/15/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: HVAC -5 72°F 115°F 43°F Conduction Area U -Value DETD 1 Btu/hr x x x x x x x x x 62.0 = = = = = = = = = 2,720 41.6 2,627 43.0 4,134 43.0 621 FxdGlsWdw 53c (Southeast) 1 3.8 48 0.289 53 ( 0.0 1 29.0 1. Design Equivalent Temperature Difference (DETD) Page Total 10,1021 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr Sld GIsDr (Entry) _(Northeast) CsmntG (Northeast) CsmntWdw H (Southeast) Sw GIsDr 53a (Southeast) FXdGISWdw (53b) (Southeast) FxdGlsWdw 53c (Southeast) 1 3.8 48 0.289 53 ( 0.0 1 29.0 ( 0.0 x X x x x X x x x x 1 + + + + + + + + + + 88.0 X X X X x x x x x x 48)X ) x x x x )x )x )x )x 0.468 = = = = = = = = = = 1,975 ( 0.0 1 3.8 48 0.289 53 ( 0.0 1 29.0 62) 0.289 520 ( 0.0 1 120.0 62) 0.468 3,479 ( 0.0 1 22.5 62) 0.468 652 ( 0.0 1 22.5 62)X 0.468 652 ( ( ( ( Sched. Page Total 7 331 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,598 x 0.500 Watts/sgft x 3.413 Btuh/Watt = 2,727 Occupants 1.00 X 1,598 X 255 Btuh/occ. / 333 sgft/occ. = 1,224 Receptacle 1.00 x 1,598 x 0.000 Watts/sqft x 3.413 Btuh/Waft = 0 Process 1.000xx 1,598 x 0.000 Waftts/sgft Ix 3.413Btuh/Watt = 0 Infiltration: � 1.00 � x �17m0 x 598 x OD x I 1.OQJ / 60] 1�3J =836 Schedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 36,22J Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants1.00 x 1 598 x 225 Btuh/OCC. / 333 sgft/occ. = 1 080 Receptacle 1.00 x 1 598 x 0.000 Watts/sgft x 3.41 Btuh/Waft = o Process 1.00 x 1 598 x 0.000 Watts/sgft x 3.41 Btuh/Watt = o Infiltration: 1.001 x 4 840 x 1 598 x 12.00 x 1.00 / 60] 0.00621 = 9 607 chedule Alr Latent Area Ceiling Height ACH Qyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 10,687 EnergyPro 3.1 By EnercySoft User Number: 3665 Job Number: 0004.00 Page: 51 of 53 0 PJ i RESIDENTIAL ROOM COOLING LOAD SUMMARY Horn Residence 1/15/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value 1 0.02751 HVAC -6 720F 115°F 43°F X X X X X X X X X DETD 1 = = = = = = = = = Btu/hr 62.0 1,764 41.6 1,807 41.6 86 43.0 4,902 1. Design Equivalent Temperature Difference (DETD) Page Total 8 559 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr Sld GlsDr 03 Southwest ( 0.0 x 1 + 180.0 X 62) X 0.468 = 5,218 S.wg.GlsDtGO _(Southwest) ( 0.0 x 1 + 120.0 x 62) X 0.468 = 3,479 ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( X + X I )X = Sched. Page Total 8 sss Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,036 X 0.500 Watts/sqft x 3.412 Btuh/Watt = 1,768 Occupants 1.00 X 1,036 X 255 Btuh/OCC. / 333 sgft/OCc. = 793 Receptacle 1.00 x 1,036 X 0.000 Watts/sgft x 3.413 Btuh/Waft = 0 Process 1.00 x 1,036 x 0.000 Watts/sqft x 3.41 BtuhlWatt = 0 Infiltration: ��_ 00 x X1-36 X x 1.00 / 60] chedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 27671 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 036 X 2251 Btuh/occ. / 333 sgft/occ. = 700 Receptacle 1.00 x 1 036 X 0.000 Watts/sgft X 3.41 Btuh/Waft = o Process r 1.00 x 1 036 X 0.000 Watts/sqft x 3.41 Btuh/Waft = Infiltration: I 1.00 x L 4,8401 x 1 03 x 9.80 x 1.00 / 60] 0.00621 = 5 087 "` chedule Alr Latent Area Ceiling Height ACH Lew Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 5,787 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0004.00 Page: 62 of 53 Is \_J RESIDENTIAL ROOM COOLING LOAD SUMMARY Horn Residence 1/15/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X DETD1 62.0 41.6 43.0 41.6 HVAC -7 72DF 115DF 430E Btu/hr 1,067 1,417 1,179 387 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 4 049 Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr CsmntWdw J1 Northwest FxdGIsVl/rf (Northwest) CsmntWdw J3 (Northwest) CsmntWdw K1 (Northwest) CsmntWdw (K4) (Northwest) CsmntWdw L (Northwest) 1 22.0 48) 0.289 306 ( 0.0 1 11.0 ( 0.0 X x x x X x x x x X 1 + + + + + + + + + + 11.0 X x x X x x X X x x 48)X x )X x )X )x )X )X 0.289 = = = = = = = = = = 153 ( 0.0 1 22.0 48) 0.289 306 ( 0.0 1 11.0 48 0.289 153 ( 0.0 1 6.0 48)x 0.289 83 ( 0.0 1 6.0 48) 0.289 83 ( 0.0 1 6.3 48)X 0.289 88 ( ( ( ( Sched. Page Total 896 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 627 x 0.500 Wafts/sgft x 3.41 BtuhlWaft = 1,070 Occupants 1.00 x 627 x 255 Btuh/occ. / 333 sgft/occ. = 480 Receptacle 1.00 x 627 x 0.000 Wafts/sgft x 3.413 Btuh/Waft = 0 Process ��1.000x�x 627 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = 0 Infiltration: �� x �L D x L 6221 x 11.00 x / 60� = 5 3�6 Schedule Air Sensible Area Ceiling Height ACH z -\T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,8011 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 627 x 225 Btuh/occ. / 333 sqft/occ. = 424 Receptacle 1.00 x 627 x 0.000 Watts/sgft x 3.41 Btuh/Waft = 0 Process 1.00 x 627 x 0.000 Wafts/sgft x 3.41 BtuhlWaft = 0 Infiltration: 1 1.00 x 4840 X 62 x 11.00 x 1.00 / 60] 1 0.00621 = 3 455 chedule AIr Latent Area Ceiling Height ACH LAW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,879 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: 0004.00 Page: 53 of 53 .01/04/2005 09:09 17603401819 PAGE 02/02 .i.v•.•y././.../:/rri✓:i:.:.:r.vv;/./.;ri.:%r/i•rrn.n./.:/r/l/vi.i•/.•py.�•�.�././:I•'n'Ii/.l✓.•%Y:n•nvvii:..•n•ni vn vi•ivivri•nuavarz•/a•i/riv.v.•n.nv/i•iv.'/:r•nn•n/i!:/:..i:: •M INSULATION CERTIFICATE This i:. ':o certify that insulation has been Installed in conformanaa with the current energy regular: on, California Administrative Code, Title 24, State of California, in the building at s 53-317 VI A LOT 274, @ THE HIDEAWAY, LA QUINTA CA CEII-I : GS: TYPE: BLOW MANUFACTURER: Certainteed THICKNESS: R-38 WALL,;: `. TYPE: BLOW MANUFACTURER: Certainteed TWECKI4ESS: R-22 GENE :;AL CONTRACTOR: STEPHEN JONES CONSTRUCTION LICENSE # TITLE: PARA:ON SCHMID BUILDING PRODUCTS A MASCO Company, LICENSE # 221517 BY: TIT>,E: ACCOUNT REPRESENTIVE. DATE: i �/ ✓ ��-:�..�..�:�.�r.�s..�.>R.as+arn�arnrs...a,.-....,.....r.�;i•,�n,✓s...ors�r.: �<i.. -. i INSULATION CERTIE'ICATE This R' r certify that insulation has been installed in conformance, with the cum nergy regulal on, lifornia Administrative Code, Title 24, State of California ja-tKe building located at CEILII, ,GS: TYPE; 3LOw MA ACTURER: Corralinteed THICKNESS: R-38 TYPE:: BATTS MA IN6CTURER: John Manville THICKNESS: R-13 GENE :IAL CONTRACTOR: LICENSE # ` BY:_.. ., - TITLE: PAR,1;60N ;SCHMID BUILDING PRODUCTS A MASCO Corripany LTCFNSE # 221517 BY: TITLE: ACCOUNT REPRESENTIVE [)ATE: . .. : , ro7i r: .r.•/.•i✓:!/'.��•=.•v.n:•�:Y%.f•.r/`..nirl'✓svr.[^:r.vr/'%n.U,.yNAird%.,!•✓yvfHNNNNis•h'.V.V iiN'i}•HN.d'%r'A'N%YNAiv /r b'n �n.7 it :s:vi e:rr. .v:s .. ii /. i. .. ,. :,-�v 4 Sladden Engineering 6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 39-725 Garand Ln., Suite G, Palm Desert, CA 92211 (760) 772-3893 Fax (760) 772-3895 August 20, 2003 Project No. 522-3325 03-07-465 Stephen Jones P.O. Box 4656 Palm Desert, California 92261 Project: Lot 274 -Via Pessaro The Hideaway Palm Desert, California 92261 Subject: 'Geotechnical Update Ref: 1. Report of Testing and Observations During Pad Regrading prepared by Sladden Engineering dated August 13, 2003, Project No. 544-2199, Report No. 03-04-225. 2. Report of Testing and Observation During Rough Grading prepared by Earth Systems Southwest (ESS) dated August 28, 2002; File No. 07117-11, Report No. 01-07-718. 3. Geotechnical Engineering Report prepared by Earth Systems Southwest dated April 11, 2001; File No. 08119-01. As requested, we have reviewed the above referenced geotechnical reports as they relate to the design and construction of the custom residence. The project site is located on Lot 274 along Via Pessaro within the �. Hideaway Golf Club development in the City of La Quinta, California. It is our understanding that the proposed residence will be a relatively lightweight wood frame structure supported by conventional shallow spread footings and concrete slabs on grade. The subject lot was previously graded during the rough grading of the Hideaway project site and was recently regraded. The rough grading included overexcavation of the native surface soils along with the placement of engineered fill material to construct the subject building pad and adjacent lots. The recent regrading included processing the surface soil along with minor cuts and fills to construct the individual building pads. Some additional overexcavation was performed in areas where the building envelopes were reconfigured. The approximate building envelope is indicated on the attached site plan. The site grading is summarized in the referenced Report of Testing and Observation During Rough Grading prepared by ESS and the recent grading report by our firm. The referenced reports include recommendations pertaining to the construction of residential structure foundations. Based upon our review of the referenced reports, it is our opinion that the structural values included in the above referenced reports remain applicable for the design and construction of the proposed 3 residential structure foundations. Because the lot has been previously rough graded, the remedial grading required at this time should be minimal. The building area should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted so that a minimum of 90 percent relative compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at near optimum.inoisture content and compacted to at least 90 percent relative compaction. 1 August 20, 2003 -2- Project No. 522-3325 03-07-465 Allowable Bearing Pressures: The allowable bearing pressures recommended in the referenced grading report remain applicable. Conventional shallow spread footings should be bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be utilized if desired. The maximum allowable bearing pressure should be 3000 psf. The recommended allowable foundation bearing pressures may be increased by one-third when considering wind and seismic loading. The bearing soils are non -expansive and fall within the "very low" expansion category in accordance with Uniform Building Code (UBC) classification criteria. Pertinent 1997 UBC Seismic Design parameters are summarized on the attached data sheet. If you have questions regarding this letter or the referenced reports, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERING Brett L. Anderson Principal Engineer SER/pc Copies: 4/Stephen Jones Sladden Engineering 51 August 20, 2003 -3- Project No. 522-3325 03-07-465 1997 UNIFORM BUILDING CODE INFORMATION The International Conference of Building Officials 1997 Uniform Building Code contains substantial revisions and additions to the earthquake engineering section in Chapter 16. Concepts contained in the code that will likely be relevant to construction of the proposed structures are summarized below. Ground shaking is expected to be the primary hazard most likely to affect the site, based upon proximity to significant faults capable of generating large earthquakes. Major fault zones considered to be most likely to create strong ground shaking at the site are listed.below. Fault Zone Approximate Distance From Site Fault Type 1997 UBC San Andreas 9.8 km A San Jacinto 26 km A Based on our field observations and understanding of local geologic conditions, the soil profile type judged applicable to this site is So, generally described as stiff or dense soil. The site is located within UBC Seismic Zone 4. The following table presents additional coefficients and factors relevant to seismic mitigation for new construction upon adoption of the 1997 code. Sladden Engineering Near -Source Near -Source Seismic Seismic Seismic Acceleration Velocity Coefficient Coefficient Source Factor, N,, Factor, N, Ce C,, San Andreas 1.01 1.22 0.44 Ne 0.64 N„ San Jacinto 1.0 1.0 0.44 Na 0.64 N„ Sladden Engineering