Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-5578 (SFD)
r' 1 . 'it; P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T-ityl 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 05-00005578 Property Address: 53353 VIA PISA APN: 772-520-059- - - Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 535952 Applicant: Architect or Engineer: LiC. No.: OOR SQUARE FOOT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals ode, aJ rp6 License is in full force and effect. License Class: B A. n 1 Lic se No.l 6R 5410 Data: toI L1 Io�- Xa ER-BDER DECLARATION I hereby affirm under penalty of perjur thatmpt f mheContractor's State License Law for the following reason (Sec. 7031.5, Busin anons e: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who -builds orimproves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). 1 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 6/12/06 Owner: MICHAEL PAPWORTH 11111 SANTA MONICA BLVD #820 LOS ANGELES, CA 90025 e ' D Contractor: JUN g"N TUSCAN CANYONS DEVELOPMENT I JUN P 0 BOX 3139 PALM DESERT, CA 92261 AP (760)774-7321 CIS A Lic. No.: 825410 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to he wort rs' yy mpensation provisions of Section 3700 of the LabWRKEPE.J"ION ith co ply ith tho}e provisions. ' Date: �PPlicant:'V11 WARNING. FAILURE TO SECURCOVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CAIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDIOF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building c n ruction, and he by autl ri representatives of this c unt to enter upon the above-mentioned prop for i ction purpose . Date:( Signature (Applicant or Agent): Application Number . . . . . 05-00005578 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 2147.50 Plan Check Fee 1395.88 Issue Date . . . . Valuation . . . . 535952 Expiration Date 12/09/06 Qty Unit Charge Per Extension BASE FEE 2039.50 36.00 ---------------------------------------------------------------------------- 3.0000 THOU BLDG 500,001-1,000,000 108.00 Permit . . . ELEC-NEW RESIDENTIAL Additional desc-. Permit Fee . . . . 266.90 Plan Check Fee 66.73 Issue Date . . . . Valuation . . . . 0 Expiration Date 12/09/06 Qty Unit Charge Per. Extension -- BASE FEE 15.00 6061.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 212.14 1238.00' .0200 ELEC GARAGE OR NON-RESIDENTIAL 24.76 1.00 ---------------------------------------------------------------------------- 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 12/09/06 Qty Unit Charge Per Extension ------------------------------= BASE ---------------------------------- FEE 15.00 ----------- Permit MECHANICAL Additional desc . Permit Fee228.50 Plan Check Fee 57.13 Issue.Date . . . . Valuation 0 Expiration Date .12/09/06 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36.00 2.00 11.0000 EA MECH FURNACE >100K 22.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 4.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 66.00 10.00 . 6.5000 EA • MECH VENT FAN 65.00 LQPERMIT Application Number 05-00005578 Permit . . . . . . MECHANICAL Qty. Unit Charge Per Extension 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 ---------------------------------------------------------------------------- Permit . . PLUMBING Additional desc . . Permit Fee . . . . 252.75 Issue Date• . . . . Expiration Date . . 12/09/06 Plan Check Fee . . 63.19 Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 28.00 6.0000 EA PLBFIXTURE 168.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 17.00 .7500 EA PLB GAS PIPE >=5 12.75 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 6061 SQ.FT.. SFD.- PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL/SPA OR DRIVEWAY APPROACH.June 12, 2006 1:38:44 PM srubio -------------------------------------------------------=--------=----------- Other Fees . . . . . . ART IN PUBLIC PLACES -RES 839.88 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 480.00 ENERGY REVIEW FEE 139.59 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 53.59 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1666.00 Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 2910.65 .00 .00 2910.65 Plan Check Total 1582.93 750.00 .00 832.93 Other Fee Total 4729.06 .00 .00 4729.06 Grand Total 9222.64 .750.00 .00 8472.64 LQPERMIT LQPERM[T Application Number . . . . . 05-00005578 P.O. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 December 18, 2006 .Mr. Mike Papworth Transamerica Investment Management 11111 Santa Monica Boulevard, Suite 820 Los Angeles, CA 90025 RE: Building Permit Extension Request - 53353 Via Pisa. Dear Mr. Papworth: U.c. FILE, fG��trCv BUILDING & SAFETY DEPARTMENT (760) 777-7012 FAX (760) 777-7011 I have reviewed your letter dated November 17, 2006, requesting a time extension for the single family residence being constructed at the above address under Building Permit #05-5578. Our records indicate the following status on this project. Inspection status: Permit issued: 6/21/06 Last successful inspection: NONE 180 -day expiration date: 12/18/06 180 -day extension date: 6/18/07 Under the provisions of California Building Code Section 106.4.4, your request is hereby granted. Because the Building Code specifies that "no permit shall be extended more than once," please be advised that unless the project passes its next required inspection on or before Monday, June 18, 2007, your building permit will expire automatically. Building & Safety Manager V 6 C/�y TRANsAMERICA/�o,N 0 2446- INVESTMENT MANAGEMENT G,gL9Q�, 11111 Santa Monica Boulevard • Suite 820 • Los Angeles CA 90025 • 310.996.3200 • fax 310.477.9767 • ww com November 17, 2006 Mr.Greg Butler Building and Safety Manager City of La Quinta P.O. Box 1504 La Quinta, Ca 92247 I own a vacant lot at the Hideaway Club, Lot 275, Address 53353 V.A. Pisa, La Quinta. The plans for a single family residence were completed in the spring of 2006 and submitted to the City of La Quinta Building Department. A building permit was issued approximately June 21, 2006. Health problems have caused a delay in construction, as it doesn't seem prudent to begin the project until I have a reasonably clean bill of health. I thought I would have a clear prognosis by now, but it looks like another 3 to 6 months before I will be reasonably sure. I don't want the $8,472.64 back since I still look forward to starting the project. My 180 -day window for starting construction will be closing in a few weeks and I would like to ask for an extension on the permit to give me more time decide the feasibility of the project. Thank you for your attention, I look forward to hearing from you. Sincerely, Mike Papworth 310-996-3223 '.6 fl,,4> 01.6K."k xUlit� t ::. l _. 'r: '3s 'i. j F r .. I F _�•' r=.. _ '°ViI;�� �`.. . , �s� .13".1 ".. V- It City of LA Quanta Publi;d 78495 Calle Tainpic . o La Q4inta, CA 92 ?-5 5 ' �$PACE A LlkffFbR-kECbfUkRS U . SE A04771 -190-62J.& 77719.64 :GRANT DEED T148 UNDERSTANDING GRANTORS) DECLARE(S.) . DOCUMENTARY TRANSFER TAX" is -E! computed oin'fWfvaW6 bf-or6pehy.66fivcy*ed, or. 0' computed odfull Valueless va'19e. of liens )i*dncuinbrances remaining w remaj .1 g at time.o sa L. Qj, unmcorpgrated area. ©City tio < 1 6k-A"VA4AA 'lLtbd)qSjDEkAT1p jece otm'.,'Ii� "�hereby h M oy. acknowledged, jwi�. if. JR. AND KAREN D..HUFFMA-N TRUSTEES:OF THE HUFFMAN FAMILY TRUST DAT . ED-�& . -21-95 hetOxGRAVT(sj to 6XVII).G, AUFFMAN, ilk. AWKAREND. HUFFMAN NIP T TRtSTEESdFTil!E-H..UFFM'AN--FAKtL-YTP,US DATEP6721-z95' the foilo%ying described 'real* property j - n'the County of Riverside; 4atepf CAI iforriia.Z s . thrpuO.B.- Th�&0.6rtibn of t;and'.ffi'I..00ts'275'&"'2761 MB -327 afft.ge .56 ":a:nd A-WHIcreof': ShO wrl. s."-asd6sdHbe 1 -13 :4n*cIu.'sivc, Riv': 'i'�&: cords a -n attached hqeto as: Parcel A. NOTE:; This 14od.orfqq� f 1���iTO.Adjqs�Tent I01"3-5212s-V.prove tbc,. C., tY ti! 'La Quanta., STA who proved fo. ane on, and that by his/heildeirsiinatuid(s). on the initTurne6t the petson(s)" or w enilty-opon bchajtot'which 'ihe pLjr - son(s).pcted..cxecuted the.instrunleni i -ccm'ify'vh&i PENALTY OF PERJURY undqrthelawt.4f:the Stott-*(. f�fiforniethat .l�e roTegoing pkra . gm.p , PIN� And -W1TNh5.S':m hyndAndoffitcl-, ' . - -.,_k 7' VERS CA AMRIGUEZ comjrijsSjoli..-* 1919544 ZNotary Public GaPtoroia. , Z. my:Cbmm. Expires Jan 2*7..*26'5 DOC #.20'13-0323509 07103/2GI-3 02:34 pM Fees: 534.09. 365: Page 1' of . 4 Redbrded ih,Qffipial Records. County of Riv4qrside tarry W. Ward:. Assessor.,.C.Pqnty kecor-Oet' Citypf.[�g Quanta. Public_ Works - 79'495 Qahe:famp.i'Co -02253 La Quanta, .CA .!,*Tfiis -documqrit. was..ele&6nically. tublfitted tothe Cdur+ o"f.ikiv(irsidt.fbr-r.epor.ding'k.! eqeipte.d-by.; MRQ17 City of LA Quanta Publi;d 78495 Calle Tainpic . o La Q4inta, CA 92 ?-5 5 ' �$PACE A LlkffFbR-kECbfUkRS U . SE A04771 -190-62J.& 77719.64 :GRANT DEED T148 UNDERSTANDING GRANTORS) DECLARE(S.) . DOCUMENTARY TRANSFER TAX" is -E! computed oin'fWfvaW6 bf-or6pehy.66fivcy*ed, or. 0' computed odfull Valueless va'19e. of liens )i*dncuinbrances remaining w remaj .1 g at time.o sa L. Qj, unmcorpgrated area. ©City tio < 1 6k-A"VA4AA 'lLtbd)qSjDEkAT1p jece otm'.,'Ii� "�hereby h M oy. acknowledged, jwi�. if. JR. AND KAREN D..HUFFMA-N TRUSTEES:OF THE HUFFMAN FAMILY TRUST DAT . ED-�& . -21-95 hetOxGRAVT(sj to 6XVII).G, AUFFMAN, ilk. AWKAREND. HUFFMAN NIP T TRtSTEESdFTil!E-H..UFFM'AN--FAKtL-YTP,US DATEP6721-z95' the foilo%ying described 'real* property j - n'the County of Riverside; 4atepf CAI iforriia.Z s . thrpuO.B.- Th�&0.6rtibn of t;and'.ffi'I..00ts'275'&"'2761 MB -327 afft.ge .56 ":a:nd A-WHIcreof': ShO wrl. s."-asd6sdHbe 1 -13 :4n*cIu.'sivc, Riv': 'i'�&: cords a -n attached hqeto as: Parcel A. NOTE:; This 14od.orfqq� f 1���iTO.Adjqs�Tent I01"3-5212s-V.prove tbc,. C., tY ti! 'La Quanta., STA who proved fo. ane on, and that by his/heildeirsiinatuid(s). on the initTurne6t the petson(s)" or w enilty-opon bchajtot'which 'ihe pLjr - son(s).pcted..cxecuted the.instrunleni i -ccm'ify'vh&i PENALTY OF PERJURY undqrthelawt.4f:the Stott-*(. f�fiforniethat .l�e roTegoing pkra . gm.p , PIN� And -W1TNh5.S':m hyndAndoffitcl-, ' . - -.,_k 7' VERS CA AMRIGUEZ comjrijsSjoli..-* 1919544 ZNotary Public GaPtoroia. , Z. my:Cbmm. Expires Jan 2*7..*26'5 City of.La*'Qulnt a* Public Works - 78495'Calfe3iinpico. 4p QuiplA., CA 92253 City. of La"Quin . t . a'Pub.H'C'Workss- 19495.'(-�a'lle! i` a : mpica La QuirftA...CA 92255 777'= -190.=601 - DOCUMENTARY TR:ANSFEItTAX.:is -11t6inpiaAed b . �n fu I :value of. pro - per . ty conveyed,. or. mntng,..�i -irili� ds� 't 11 cam uted on fU'jf-*.,�Ajb '�:-Viffue ofji'eris,:or dhi-combi ift&YEM 'R. 0.. .. PP. -D 119,111corpgrated area: of-La-()�ih 'A -N - --- .. -__. "" FdkA�AW-ABE CON$ DERATIO", . r6ccipt-of'whichis.h re y-acRn"ow'I'e..&d' - - NAME: 'DAVIDG. T OFTHE V MLY TRUST 6-31-9-4 hereby GR:ANT('s)•it. 'DAVAD j "N_ -H.OFFkA lRU§tEES OFTI.4.E. AMWY T 6WD 6-11 the fo)toiving RiV6i-gide,'.St�iteof,'C-alff6rnid:;. describedreal%C property in the Conti yof 94�i-a.5-,xpconIq 7 at Pa&06-thi6dgh.B ' 9; T-hat.imtti(j:riof'llandin:L,Ois*:.7-15 216,-Of..Amqqci�dTract NO. -"-298' J on 3�- k 'S ims de 6unt c I We i; in i 4dc�s5r...cjO�p tu§ Ve ri and-' heretb� aiini i own p .ccords 2 13-5-23-4s. zippTbved:6.y gr E a.Quiritzi; NOS Ec This grant e dt -Line zAOj P sin h iin 10 F. SA, TRUSTDAT P( Ml- 5.wdl 'kN STXTF,:OF CALIFO . fA Q: J)AV! D.Q: U FFMA qpft N TNTY OF.RjYERS).DF,. &lbre sm ce, Tcl L&,7 , zv, (i,risen nailic ;n'O 0!1��OfffieWW •nall iied,., . KAREN AlURE DAIURE rustcc vkosv'rmnnc(s) is/zkr ielt&Y-exe. sane in. -:hi Is/herlitciraut on a "ija VERONICA CDRIPUEZ me thni'Ws cutdft and that byhisAvcrlaicirsitnaiuri(i)an tilt: instrurcilftp�jbn(s) orth� 54 4.'::: Cmm�sI 1919544', z Idatify, under FFNA'L-ry of.. Z. 064 Rlvers.ide'G IVY- 77 My.,C omm.. Ej6i(es.jjn,2_7F,:201i 54. %VIINESS-rX4d.alndo i0al State of -califo,"enia''. A: County of Riverside -Y--. Q. befo(ee,s(j.8,AN MAYSELS,j. Notary Public*,. 0 TIMOTHYA J NASSON'.Who proved. to: me the� ,qrso'bally-appe6r0d. 0 iscri basisofsatis tory. -evidence. io :befhe person twhose. name.: is sub eid' to the W.ithinn istru.m.er�i.,,:ano.oQknowl'edge,.d t ,e That he bxecuted.'t'116 same d --I)d that by'hj§!. signatureon- the i 'strument the' in his' authorized. person;: thd entity upon' behalf0f which the -person acted.. -executed. the : . instrument... I. I a c ify u'hde'*'. '�.P_ NALTY.".OF"PE.. JURY 6, d r. the ' M s of the S .tate- of. P-blif 6'rnia -thatQFIP paragraph . is. true acid .correct:, WITN'ES'S", my'.h,and''-and".:o-'ff'..i.*!;ial'seal: SUSAN MAY$ELS commis's"ion:9 207258 Notary-pu6tic'r Galifotvla> My Comm. Expirei -Apr 4 1�20i 7 - ----------- It, - - - - - - - - - DOCU.M T;.I. LOT LINE ADJUSTMirNT -021 and 771- 0 2, 777-i;8.0-02:1 EXHIBIT "A?' LOT LM.A.04USTMENT 2013-5.23 PARCEL A. LOTS 275 - AND 776 OF AMENDED TRACT NO."29894-2 AS S-14OWN IN MAP ,8OOK- "32 . 7, P.A.6-E.S..56TI-iROUGH*.8&i..INCLt]SI-VEj RECORDS 05'klV.ERq]DE':: COUNTY, CALIFORNIA, IN THE:OTY Of:LA .QUINTA EXCEPTINQ THEREFROM THAI PORTION. OI~ .SAID L -476 Ml ORE PARTICULARLY DESCRIBED D �S FOLLOWS; 'BEGINNING AT THE: SOUTH WESTERLY "CORNER OF SAID LOT 2761t THENCE ALONG THE WESTERLY LINE.-OF-SAID.LiOT.:276 NORTH _-, ..-: - "... - - � .-;..: WESTERLY - _w .,., :; . ... LINE FEET;*.. - 12. 6* 1 - 8 .'*05 " " - - WE. -ST A..;D!$.TA.N - QE - OF 3��, . 63 " A 0 THENCE NORTH 70`15'5'5�� EAST DISTAN.M.M103-- -:r,'E_ETT0A _iSAID-LO 2-7& POINT ON THE EASTERLY0 LINE ',rffE- N.CE -ALONG THE EASTERLY LINE OF. SAID LOT. 276 'SOU -n -I -SOJUT-f-it, ZLY:_ 02°49'447 - WA E S T. I A DISTANCE 0. V. 6 0.2 9. FE E.T-.,- Tb t4t x -0ANER Of;:$AID..-LOT-27C Y -LINE -0-1. 5' -0 7 TmNi�E ALON TTUE 900MRt'... F 6SOU114 7018-1fl" WEST AJINST-ANP <?F 186.QF-T-'T0 POINT OF FE, T-.H-E-:.PGlN. "' STAID -.A W UJS T"P'A. k -A,_ 'TAINING 36,52-6. FEET .MORE OR LESS: 275.'276ALLAo. -q23'd"''*' . - . .2. i3: � i ocx q I I EXHIBIT "B" IE•EN E)OS1ING10f UNE LOT 6k jb ABANDONED. SCALE, -1'"=W:- 120 LOT UNEADJUST 20131R523* PREPARED BY : LAND � � o o ���oP�E KEC��y�Fto� .78-080 -CALLS A1146 .501TE 102 - V2No.. 668.7 1 S!". LA -OU , CA 92253 76C'-2/-9886 -766262-joop (FA x) 14L da XFJA'DATE E .. . rrmappili,&I CoTn: D JLS:6687 LILEHER,EM". -6-3044 "'OF CP -A wm N.89�6- -E 3.7:59, AAGM 7: 29894-2 co MB 27156-!88) :VbA g . A AWWDiD 71? 29594--2 40 327155-48 10'PUE 26,869 -W-) PARCEL A 36,54 $F Co.. C14 < ajO� 274-. ARMED 7C.298,94-2 CAD MB 427,f56-88: 14 740. SF) C6 86 30.. LC) —(N7 6 .10 PAPARCELB-': 04' C) X107 -SF .28 (LOT 277 j "WED 7R.2094-2 AiBj27156-88 14,124 So AOT AA 7R 29894-2 1693' j ,118 .327156-M) (LOT :278). is IE•EN E)OS1ING10f UNE LOT 6k jb ABANDONED. SCALE, -1'"=W:- 120 LOT UNEADJUST 20131R523* PREPARED BY : LAND � � o o ���oP�E KEC��y�Fto� .78-080 -CALLS A1146 .501TE 102 - V2No.. 668.7 1 S!". LA -OU , CA 92253 76C'-2/-9886 -766262-joop (FA x) 14L da XFJA'DATE E .. . rrmappili,&I CoTn: D JLS:6687 LILEHER,EM". -6-3044 "'OF CP -A wm January 28, 2014 Mr. and Mrs. David Huffman - 6 Weatherly Drive Coto De Caza, CA 92679 Re: Lot 275/276 at 53353 Via Pisa Preliminary Design Review #1/Final Construction Documents #1 Dear Mr. and Mrs. Huffman, The Hideaway Design Review Committee (DRC) met to review your preliminary design/final design submittal at their January 21, 2014 meeting. The project was approved to start construction subject to the following items being addressed prior to the request for setback observation at the lot. 1. Based on the existing conditions it appears that the 5' high privacy wall at the deck may not be necessary; however, written acceptance from the neighbor should be provided otherwise a privacy wall will be required during construction. You may contact Sonia Millan at the Association office for contact information for Mr. and Mrs. 'Robinson. 2. Details and specifications for all wall mounted lights, showing conformance with the guidelines, are required. 3. The massing for roofs above 20' was calculated incorrectly but the massing does work as proposed. Thank you for your submittal. Please contact Brook Marshall at 760-219-8057 or by email at DRCFacilitator cr Um.ail.com with any questions or to schedule your Pre -Construction Meeting once a Building Permit has been obtained through the City. Sincerely, The Hideaway Design Review Committee cc: AntonRStracts.com GustavonGMFuture.DesiL,ns.com Davidjacobsen@aol.com DGHuffman@gmail.com DRC File Plan Submittal Building Permit Number. Project Description: SFR Exempt: 13 (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan 1/9/2014 Job Site Address I 53353 Va Pisa Owner's Name Number, Street, or PO Box City, State, Postal Code Owner's Phone Number Owner's E -Mail Address Huffman Residence 49950 Jefferson St., #130 Indio, CA 92201 Project Manager's Namel August Iacono Project Manegers Phone Number 951-634-6381 Project Managers E-mail Address I auaustMaconodevelooment com Builder / Contri Number, Street or PO City, State, Postal C Project Square Foo Monarch Homes 49950 Jefferson St., #130 Indio, CA 92201 14,400 City Approval By - Date.of City Materials To -Be Pratlitct Tons Trash 27.36 Not recyclable Product Tons Asphalt 0.00 Recyclable Masonry (broken) 0.00 Recyclable Brick/Block 0.00 Recyclable Plaster 2.88 Recyclable Cardboard 4.75 Recyclable Scrap Metal 0.00 Recyclable Commingled 0.00 Recyclable Tile (floor) 2.45 Recyclable Concrete 1.15 Recyclable Tile (roof) 0.00 Recyclable Drywall 0.85 Recyclable Wood 36.00 Recyclable Donated / Reuse` 0.00 Recyclable Landscape Debris 0.00 Recyclable "Describe Items Totals: Recycle Trash Projected Diversion: 48111 27.4 63.7% I understand it Is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, Implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP Is issued In the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. tractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still Issued In the n e of the p owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered The p rty (s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. If s - use aterial from this project site must be taken to an approved recycler or transfer station. I (1JI .'JO 1-9-11 Owkt/ Develo rojsct Menager / Superintendent Date I— PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALI M ESA CANYON LAKE COACHELLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO LAKE ELSINORE LA QUINTA MENIFEE MORENO VALLEY PALM DESERT PERRIS RANCHO MIRAGE RUBIDOUx CSD SAN JACINTO TEMECULA WILDOMAR BOARD OF SUPERVISORS: BOB BUSTER DISTRICT 1 JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 MARION ASHLEY DISTRICT 5 RIVERSIDE COUNTY FIRE DEPARTMENT IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montanas Rd., Ste. #201, Palm Desert,.CA 922114131 • Phone (760) 863-8886 • Fax(760)863-7072 www.rvcfire.org February 5, 2014 Residential Fire Systems Re: Residential Fire Sprinkler Plan Review LAQ-14-RS-008 Huffman Residence 53-353 Via Pisa La Quinta, CA The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department Planning & Engineering personnel and are approved with the following conditions: A minimum of three spare fire sprinklers of each type and temperature rating along with a sprinkler wrench should be located in a spare head cabinet at the system riser or other approved location. Permanently marked identification signs shall be attached to all control valves. A warning sign, with minimum '/ inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protections specialist. DO NOT remove this sign. The following inspections/tests are required to be witnessed by the Fire Department Planning Division staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. (b) Final inspection. The Fire Department job card, approved plans and conditions letter must be at the job site or NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection date. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection. Sincerely, 0 -Jas Stubble Fire Safety Specialist CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET' PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 9/25/2009 Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are. complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date: �/—& VDeveloper: Q ES r) `r'acf b.: GL4 golJ;- T act Name: I Gi'tC -Ay _ Lot No.(s): Z%SZ 7 Address(s): ��'3S3 V/,J / I JA Phone Number. cJ ) (937' 0-?gl The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the Building & Safety Department: CUSTOM HOMES: PROVIDE ITEMS #2. #3. #4. #5 & #7 BELOW ❖ TRACT HOMES: PROVIDE ITEMS #1. #2, #3 & #5 BELOW ❖ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1. #2 #3 #5 & #7 BELOW ❖ WALLS, SIGNS, OTHER: PROVIDE ITEM #6 BELOW 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation Certificate can be provided. 2. Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils Engineer. Recently rough graded residential developments which have a previously approved geotechnical certification are exempt from this requirement. 3. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots. 4. Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10,plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 certification number is required. 5. Attach a copy of the rough or precise grading plan to the Public Works Department showing building locations) for pad elevation verification. AO flood'zone developments will require an approved flood plain development plan. 6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. 7. Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW approved building construction projects require either a WQMP or a completed WQMP exemption form. Approved maps/plans may be viewed at the following link: http://www.la-guinta.org/PlanCheck/m search.aspx I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff. CE v Recommended by: Date: Z / �� Public Works Distribution: ( Green Sheet to Building & Safety ( ) Green Sheet to Planning Department SAN 082014 Declined for approval for reason(s) as follow(s), please correct and resubmit: COrgC N TO1F' LA QUjn(�A DEVELOPMENT f TACheddists - Forms & ApplicationslFonns & Applications\GREEN SHEET cover & PM10less than 1 Acre Revised 9-25-09.doc City of La Quinta - PM10 Fugitive Dust Control Project Information Construction Phase PM1n Anrppmpnt 1<1 acrp/Int nr Infill Prnipr_tl Project Information Project Contractor,: Project Phase (check one) Construction Demolition / �/YjfS Project Name: �" 0?6Ide-A)C E /� Project Tract/Lot Numbers: _?I�Gd- A } C- L ri 20 / 32-- Project Street Address: S3 - 3 S 3 V// A H/� SA �� Z Z S 3 Total Acres in Active Construction <1 ac per Lot): S 1-0 4 ? Anticipated Start Date: Anticipated Completion Date: /-/ / PM10 Contact Information Please note: Dust control is required 24 hours a day, 7 days a week, regardless of construction status. Person listed below is responsible for dust control during business and non -business hours. Name: v GJs 7 a Title: 2d Vr Cr MAO ACompany Name: MOrJ(1# /YI rS Mailing Address: Sb X S6 $ % /3 0 City, State, ZIP Code: 2-0 / Primary Phone M S� l0 i �' % i $ / Fax #: 206 i 1 ' g 39 24 Hour Emergency Phone#: '?Sl Cell Phone M 51 (0 i �• �0 i / Email Address: __ // r1 GJ5rc COA0dtVe114r&.J1 COM PM 10 Certificate M V 3 ' Q - �-O The above stated property owner (or authorized representative): ❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; ❖ Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. ❖ Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; ❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; ❖ Shall authorize re ntatives of City/County to enter the property for inspection and/or abatement purposes; ❖ Shall hold harrpress th# City/County and its representatives from liability for any actions related to this dust control plan or<Z�initiated abatement activities. &-.I S T 5::4 CoAJ fl 1'0'-1 Signature of Pro Owner or Authorized Representative Date T:%Cheddists - Forms & Applications%Forms & Applicalfons%GREEN SHEET cover & PM10less than 1 Acre Revised 9-25-09.doc Pl-EASt COMP L.-&64iiIS IWORMATION RECORDING REQUESTED By,; . ode 365. AND WHEN RECORDED MAIL -TD:: City o .L;§ Guihta 7.8-495 Calle Tampico. La Quinta ..CA 92253: - this.c'leed i's exec— Wed. in c6linte rt: rp-7 TAA: 020-m.- .-DTT.,..247j5Q DOC #-'2.013-0323510 W/0/2013 021,34 -PM F66s-. '43.00 Pagel of .. 7' bpp T'Tax �Paid R,e,c8rde.�,'.in Offi6ipf",ke.C.P.rds County o.f.kiv6rs;id6 'Larry W. -Miied Assessbf, Qbu*,Clerk.& Recorder'tThls dbtUrrieht.was.-6tecttcihicallg submitted tp..the�Cpunty pf.R..iver Rdceipited by; MRIJIZ - ice above 11iis Gne for recorders Use only. - -rHlS,PAJGE'.AbbEb TO -PROVIDE'A-DEQUATE:-,$PAC.,E.FOR RECORDING INFORMATION .($3.00 Additional Recording Fee -A-pplieg)-- -Ad'238 (Rev 0312008) Ji. :. SIZE - . - -1 -DA- MISC NO RFD COPY 426 PCOR NC OR SMF NCNG. crY UNI ice above 11iis Gne for recorders Use only. - -rHlS,PAJGE'.AbbEb TO -PROVIDE'A-DEQUATE:-,$PAC.,E.FOR RECORDING INFORMATION .($3.00 Additional Recording Fee -A-pplieg)-- -Ad'238 (Rev 0312008) City of La Quinta Public W...prk.s 79-495'Calle Tampico La' Quinti; OL'92253 City .of La Quihta-.Piublic 1Wo4d. 7$-495'. Calle -Tarn PTC '01 I;2 :92253 APN 1 & 662 GRANT DEED THE UNDFMTANDIIN.G. GRAIWOR(S) DECLARE(S) _.�t TAXis-$ Q computed on ful . [value . df-piope . r . ty . conveyed; eaj or cornputed*on.full'y2ilue less. value :of"I-ens.:qr encurriFirancesretnaining.afiime of sale: Q) City, La.Q�int , hZNR z Q0 WALTER LACK LU -ND-SFPARATE PROPERTY' rVLA.RRIED MANASMS: SOLE A NAME' -4NT:. .. SUFF. ' DAVTD AN15'KARIEI4.DHTFMAN ' R TpUSTEES OF-THE-jjiTF't�2Aa'`i FAMILY-T,R.U.STIDATBD 5-21-95_ Bert b J& y 9RANvr(�).. . ALTERLA-CK--- lWa ... W� A,$ IPL§.`PROPERTY the fotlowiiig described Teal in the Coiuity 'of Riv&fide, Stateof Californias: That portinri oflAndjn'tots f4&�� t:jvc).-'2§8§'4�-2asrecorded. on hereof. ers" A iLil' Sh6i7ft d6C'oun'tY �_-nd'W.': iicfi�� hereto -an '_rn ez part Jnc.. Recorftas descri.ed in.. .1 its, as .' � �3-• NOTE- Thi§.gtintd6rdgerfecti-tine:irit6ht-6f-Le,Liiie.Adju��20137523:asapgoved�yieCityqqfLaQpmta. STATE OF CALIFORNIA K WALTERIAC 00,UNTY 01 R17YERSID.B. J, on om vh*oo proved to me on the basis .orsejisf4gory•cvidence!o'be.tM poirsori(s whosena;=6)�V* subscdbjd'(x),dre within- frim jstnenand ack-novOedl rc,ekhat . . hels, �&O'E'y.'& exuted-the siirnejffi. hisrherYtheir auiborbzd -Capack) and 6t t by rise tr,strntnent tits person(s), or tt '"16--thd 0,rso; . i . (s) acteA. zib:zjited the instrument. 40A behalf -of—... I certify urw k� � �LLT.Y:OF PERF%dkY-'- -.Wifoi-niia.that the foregoing paragraph' is true. and 'comzL ��my fiari]d'arxi.pffi6al s JESSICA ECHEVERRI Pnrfr.siOfi 0 7980457 i%o uyubric - bijftornia Los Ales .d0!U'ntY my Comm- Expires Jun 29, 2016 KATLE'. 'b.:HUk'FMA1V City of La-Quitita Public Works. .78*495.Calle'rdmmcq ,L11 Quinta, CA 02-7.5.3 City ofL6 Quinta Public WOWS 78-4-95.Caj!p T_ampiO: I.,,a Opinta, -CA.922$3 DO dum F'.-N,rX KY*fRA'N.'S,' FE'R' TA x C I computed on -f6i I'-v4lue: otpr ope r ty qWnypYi4"...or. 0 -computed on r1ill valdeIes's'wdue "of liens 6 'ehaimbrah u .. rc inin- at me -of sale.. of F A .0 YALU- k LE CONSf PERATION iOt of iVhid WALTER — .-. . ... ., '8 ,0 Sr ARkTE: ROPERTY - 61, AMARRIED.JYMN, A D. SfjjS EP. AND— DAVID' G_IIU'FFMAN,,JR-AN`YK)MEN D. HUFFMAN ` TRUSTEES (YFTHE H UFFM' ]FAMILY TRUST DAI.'-ED..-&,.2-1.=,95 hereby GRANT(s) to: IvVAtER.LACK -,N - V AME. -A NIXRMED MAN A -SHISSOL9 AND SEPARATE PROPER -1 ' f �lifornia: y inthe. County -QfJ�Ner.gldc,'State , "Ci. the pilowind-(i6s.d.ribj�d.re4l,proptrr rgoii of land ln`ots'276,&,*277,.o T A.i..11ebded Tract -o iies 56'thrbutiiil8; iiclusNit "R'i"Vdisi'de;C6.u6iy.-.iketoTds as described in,Ekhibit's "A",411d."B"'amiched beret&,Od -MOC..-Wp;k[I I1CMOf -;SD OM, .-aS , Par -cel. W f., w'O", t"', L uI a.. VQTE- This gapt,deed:perfe the intent oftot 6ne.Adj'u.stin n ��t.201. I -, ". ' F 0� iat,d j tkl'�� - J-�i i:, 2--' 1 __'i :STATE-OF'CAtl . FORNIA- CO N T Y. OoklVtlt§IDS, X). L .2 L (inset fi.tffw "and 141c'of.tWarricer) '%Yho pfuvWti) rnwonthe .basis � of $aj)s!pC!Ory't-VIQt;nGCAO UU-I tvhase , ntnKs,) , Wa;� SUb,S,;rj,bL,-d lb ffcwil in insijunien.,iand nm that he/sWilicy exemiled.i6samein hiVhcdtheie*aq!Jidri .and *that by . hWhiCilth6l' Si gnBIUM(S) Oh thZ:IIISIWMLnI Ott' Pei entity upon [xhaFfof which the pcnort(s) at tej c�ctuwd the q� f AI= -SS � corre Y. *0 and official 8VA di. K LT.. TifI.JUFF DA'tD G-21-95 :DAVID--GII.Uff. A !t,ru I CALIFORNIA ALL-PURPOSE URPOSE ACKNOWLEDGMENT., State of California: 4 before�Me VOUITIVIAVA J pappeared-:U;.; erspnally. V.ERONICA. ROORIGAJEZ dc)mrjissjo*6 #.'lqlSS44. =m tfotary Public =California. Z' Riverside Coun MY.Conim. ian'2i'26j: 7�- 7 who prmied to m6 bn,fhb basis of'-satisfact&y evidence to be the:pefsbn(sj' whose *,"h'*�a'm':.e(8').-is/a.r.e"sub..s.tdb6.d to the;w4h . in instrument. . 49,8: ack . how!eog*ed to rb . ia thit helshe6ey executed the :same `in Ms(h0i/thelr authorized b capacity(ies), and that .11.6y. on th. � instrument the personkil, - or :Elie. entity upon _behalf of. which the 06'r'si-o'n(§).ACt4d,'65(etLitL-d #*.-.6sVurnent, t c6ftify under PENALTY OF PERJUSY uhd&r'.the of the State . of'-C61ifornla-dist the' is, thje"�' I correct: . p.q.... WITNES8 rpy,hand:::and-offi6fal seat. 7 Signaturi piace`NatarySoil A46%;i$$igttatf QPTfOIVALI. Thou theis:nof re..qijired*by-laW,.#:a?qy P.rlqt�e Wuable'(o persons retying 00 the document : irierrt , - oi il , * *- " infonnali fhoual anaF. r0_ 40h and iould b6sciloliod of Atfadhed l3ocu merit:. Titleb*i Type of Mdun W& t-Vf .:U - '%A% bb.ciniehl: este: S dfhe'r'Th .,Na:i`!)6d Ab6vL* ...pay.(ies) q!0J; I I Individual :0 Cer: -I.:). I'L'iffii ted. I J Genera.1. It i . i AttoTepn Top anNiffib hare �.L.i Trustee 't J. 'Gpgdian'or .0grisematpIr Signal Is Ropresenfirig"_ ASSWAtion- 0350 Do Solo, Ave; PCL -Box 2402-chatSA"DI'llk. Sjgner'.s Narnq.._.: A. I:IndividuW:: l.p6rther_j:.l.LirnftiErd I.I.-General �.eyj- Fact r'm ) " mj'a" L I I Trustee 1.*,09ardian!o�r ppmerycitor, vi MtN - ammom [turn 959m 72oardm-. W Toll-Rce I -Ro0.876=(W State of, Calilf-6-rhia.: doaUnty of RIvetsIdio.-. On p.re me:j .8'OSA4 VAYSE.M Notary PU'blllC:, personally :6 6e4had. TIMOTHY R. JONASSQN Wbb proved i6..'rfib on the basis of satisfacto.ry evidence to be the persbnil: Whose name is 'subscrib6d.to the within instrument and acknowledged to. me. that he' executed fh-6 same in: hjs.abihorji, y, .ecappqi.t qpo' that ' by his signature is:$igrato.re. the 'I 'nstrament the Oersioni..6'r the en.ti.t.y.upon. behalf of w i.t. h theperson: acted ,. executed the in'st'rurnen.ti: certify.. Ljnder PENALTY OF * PERJURY . `.under the laftof th,6 - State of Ca[if.b.ml.a:that -the foreg.p . ing.ppraglap,b is true and :correct:..:eo:correct:..: WITN ESS b6ho and official seal.: MAYSELS' Oary Public:- Calif Mia i. Comm.Si natute .. kSy kpifes.Apr 13,: 26i7 DO.CUMENT; 7.7-1-00-0 -2 A . Q -*r - and ;777 �!NEAPJO.,5T.I:E'NT'NO.-�2O.I.-�-3-;�..'3�re. MP LOT. 10.0-0:02 EXHIBIT`. 'A" LOT LIKE.:AI)JUSTWNT 2O13✓ -523 PARCF,4-.- A - LOTS '275 AND 276 OF AMENDED TRACTNO.29.894-2 AS: SHOWN IN MAP BOOK 32.PAGES 6THROU014-88, INCLUSIVE, RECORDS OF RIVERSIDE COUNTY,. STATE-OF.CALIFORNTA,IN-THE.CITY OF L&OUINTA, EXCEPTING., THEk*F-FROM.tHA PORTION OF SAID. . D. LOT. 2 u 7§ MORETARTIC LA.RLY A' DUM. BED .. 8 FOLLOWS:. BEGE4KNO AT THE SOUTHW EST5RLY CORNER Orz*-SAII) LOT 276, THENCE ALONG THE ESTERLY - 4INE OF SAID LOT 276 Nl.0RTFl i2°18'-65:" ' WEST- A:DISTANCE W ITST.- - AN-.- C. E.- Or 36:63 FEET-, THENCE -NORTH.70019"55" EAST . A DISTANCE QF`. -203:66 FEET TO A.. POINT ON THE EASTERLY LINE THENCE ALONG THE, FASTERLY"LINE OF SAID LOT276 SOUTH E -SOUTHEASTERLY CORNER-OF'SAID IOT'276.t' THENCE ALONG THE SOU I HERI Y. LINE OF SAID LOT 276 SOUTH EE -T.; TO. THE POINT OF 7601.81.0" WE5T-A---PlSm�--a OF -186N.F BECTINNIN -SAID ADJUST 'PAkCFt A Cb Nt:4!NING 35,526 SQUARE FEET, MORE OR, LESS. -j- KE -Q OR' E* OAR* lED BY: OF' C Ql iune-19: 2013 r & UX�ERES6687 275-276ILL4 2013-523AOCX .EXHIBIT'/iA,7' ..LOT L.11NE ADJU.STMENT 2013_523: PARCEL B: LOT2 : 770 . F AMENDED. V WN IN MAP BO OK .327 . .RA-C.-T--N.O..29894-2-.A,S-.'$IiO'" F RIVERSIDE . -0 PAGES THROUGH .89, INCLUSIVE -E S - .8. C UNTY, RE.CdW�S'b AIV. STATE OF CALIFORNIA, INTHE CITY'Of LA;QUINTA TOGETHER WITH TW.� ,pOi�OF. LOT TRACT NO. 29894 7 iN40REf PARTICULARLY DESCRIBED AS: FOLLOWS,; BEG", INGAT THE SOUTHWESTERLY CORNER -OF,&AlIDJOT 176' THE\ ICE ALONG THE WE$T--.ERL-. Y'LINE OF SAID :LOT 276 NORTH ..12619'.'0'5"WEST' ADISTANCE .OF'36'.'63FEET..I:. THENCE NORTIf'70019'55" EAST A DISTANCE OF* -203..66 FEET TOA: POINT _614 -THE .8 TERLY L'IN"E'c'O"'F::'S-A'*'*IDLLO"T. 2-164�.; . THEN CE,-AL6N.'*THE.EASI'..tk-!;Y'LINE-:OF-ISAiDLbT"276 SOUTH' THE SOUTHEASTERLY 62Q49'�O.'..'..WES.T-A,..DIS.TANCE.-.OF6O.Z9-F-EETTO -CORNER_,O.F. *SAID'LOT 276; 'TI.INCE ALONG T.HE'..S.6U.T.H8k.LY,']L.RqEOF. 8ADLOT I.76 -SOUTH 7601'9'107V'ESTAD15T.A CE -.'OF A-86-30'FEE-T TO THE POINT'OF '88.01-NNINia- At-T MORE OR SA-It.)ADJ.TJ..gTED'..P'AR�',EL]�:t-OWAINTNO-'1-4, 7ISQUARE .LESS. Ej, RVE,YV0b1..q0*- 275 2761LLA 2013-521dock. Pagel of 3 EXHIBIT "Be' N891 -20 E\ 37.59' :(ibr 274' LA AUBVDM 7R 298.94-2 LA C 46 3271-56-68). 4-011 JP'. ODii. (LOT -075 0. us 327156-881 10'PUE.. :77 .24869 SF) PARCEL A Po 36,516. SF ' 3- ;. C9. 0 Of 2T6 m AAlENDED.7k 29894-2 cp k8 327156-n8il > lit746 9)� An PARCEL B` cv 24,207 SP r-> LOT 277 28 LEGEND Co-' EXIST* LOT LINE LOT UNE TO BE (Wr AA ABANPONED OT 2094-2 AMM UNE M8 327156-88): GALE III= .609 :0 30. .-004 120 180 —......LOT LINE ADJUST 2013-523 PREPARED.BY;;. i6 LAND., t"In 00 HIER NZMPFOU'�' (9: MUE K 78 -E -08-0 CALLEAWV O; ,S. VT /W No 6687 -,CA 7760-219-988 '�R-i4- dalefig).kellchennappin -ro= g, ALE KELL5 0 LSa. 6 87 X*P. 6,3 -1.1 J Ji. Eiectronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/18/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 2/20/2014 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Huffman Residence Building Type Rl Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/18/2014 Project Address Hideaway Lot #275-276 La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 9,348 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity f Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 8,585 Radiant Barrier New Wall Wood Framed R-21 8,503 New Slab Unheated Slab -on -Grade None 8,585 Perim = 627' New Door Opaque Door None 24 New FENESTRATION U- Exterior Orientation Area(fe) Factor SHGC Overhang Sidefins Shades Status Rear (N) 557.2 0.510 0.39 none none Bug Screen New Rear (NE) 160.0 0.510,,vp-q*,_0.39_none, ,,---„none 4-,„Q—Bug Screen r**,— New Front (S)yt"J Y 426.9 rl 0 510 1 0.39 "`nonev ` none, 47 l( ,Bug Screen 2New Left (Vl ' r” X257.0 �% /0.510 0.39 - non'e % !' .rn'one I `, Bug Screen k4. New Left (NVV)'. jk'o fl 0.510 0.'39 none P.' R -none j ;.,,BugScreen� '14 New +14.) Right (E)w�'„t"+'�462.4 X0.510 ,,. y0.39' none - �� ; hone, _ . Bug ScreenLNew L _ t I w r-, f 1 A. ,f"w 9 an, a — yyF 1 III rla�fr. n A HVAC SYSTEMS i h J. j ON Qty. HeatingMin. Eff CoolingMi Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditione 16..-0-5 R-- Y etback New 2 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER SaKakk New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Large Gas 75 0.82 All Pipes Ins New EnergyPro 5.1 by Ener Soft User Number: 6712 RunCode: 201402-18714:24:44 ID: Pae 1 of 12 Reg: 213-NO09641BB-000000000-0000 Registration Date/Time: 2013/12/26 19:35:58 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/18/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 2/20/2014 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Huffman Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/18/2014 Project Address Hideaway Lot #275-276 La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 9,348 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity f Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft`) Factor SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Fumace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 6 Ducted Ducted Attic, Ce ling Inrvented_ 8.0 New HVAC 7 Ducted Ducted Attic, Ceilin -his, ��iented- —'-7870—,New g 1� a � WATER HEATING ulLE..) � `� 1.,) 1N7 -q Ot . Type Gallons Min. Eff /[D*stribution,.,, _, FC_7Y pF�T + tatus F ' , i - VPn Or� , , _. Yv l VCT! DATF BY EnergyPro 5.1 by EnergySoft User Number.' 6712 RunCode: 2014-02-18T14:24:44 ID: Pa e 2 of 12 -----J Reg: 213-N0096418B-000000000-0000 Registration Date/Time: 2013/12/26 19:35:58 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/18/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 2/20/2014 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Huffman Residence 1 ❑ Multi Family ❑ Existing+ Addition/Alteration I 2/1 RI2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford White M-1-75S6BN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 988.0 ft2 Covered Slab Floor, 3.500" thick at Master Bedroom HIGH MASS Design - Verify Thermal Mass: 465.0 ft2 Exposed Slab Floor, 3.500" thick at Master Bedroom HIGH MASS Design - Verify Thermal Mass: 1,467.0 ftz Covered Slab Floor, 3.500" thick at Casita Office Bed 4 & 5 HIGH MASS Design - Verify Thermal Mass: 315.0 ft2 Exposed Slab Floor, 3.500" thick at Casita Office Bed 4 & 5 HIGH MASS Design - Verify Thermal Mass: 56 1. 0 ft2 Exposed Slab Floor, 3.500" thick at Entry Dining The HVAC System HVAC 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design -Verify Thermal Mass: 1,488.0 ft2 Covered Slab Floor, 3.500" thick at Kitchen Great HIGH MASS Design - Verify Thermal Mass: 626.0 ftz Exposed Slab Floor, 3.500" thick at Kitchen Great The HVAC System HVAC 5 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 161.0 ft' Covered Slab Floor, 3.500" thick at Morning Catering HIGH MASS Design - Verify Thermal Mass: 1,504.0 ft= Exposed Slab Floor, 3.500" thick at Morning Catering HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24ANB748 / 58CVX090 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge ora Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ANB748 / 58CVX090 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 & 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ANB760 / 58PH"110 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge ora Charge Indicator Display. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. ! (: + ,• - ---�� The Cooling System Carrier 24AN8760 /58PH`"110 includes credit for a 13.0 EER Condenser. `A certified HERS'rater must:fie/d'verify t. a installation of the correct Condenser. L -JI' U/ The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. �1`C DEP r'i Ir The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and -diagnostic, testing is required -to erify that duct leakage meets the specified criteria. Ene Pro5.1 6 Ene ySoft User Number. 6712 RunCode: 2014-02-18T14:24:44 Reg: 213-N0096418B-000000000-0000 Registration Date/Time: 2013/12/26 19:35:58 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/18/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 2/20/2014 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Huffman Residence Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/18/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC 6 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 868.0 ft' Covered Slab Floor, 3.500" thick at Bed 2 & 3 HIGH MASS Design - Verify Thermal Mass: 142.0 ft2 Exposed Slab Floor, 3.500" thick at Bed 2 & 3 The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. ,r� K i 1 /J1,/� ��w,/►�Jj f Air tel. HERS REQUIRED, VERIFICATION -..�+' F �' ` - � t �:�'r � .ter Items in this section require field testing and/or ver -a certified HERS -Rater. The'inspectoramust receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24ANB748 / 58CVX090 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 6 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 6 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ANB736 / 58PH"045 includes credit for a 12.9 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 7 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The. HVAC System HVAC 7 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. LA � �LDi(IJ �J R L1 A _9tJ/ #7_ ""r✓®�,STPUCTIp Af c��rE RV EnerqyPro 5.1 by EnemySoft User Number: 6712 RunCode: 201402-18714:24:44 ID: Page 4 of 12 Reg: 213-N0096418B-000000000-0000 Registration Date/Time: 2013/12/26 19:35:58 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 2/18/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 2/20/2014 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Huffman Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 1 2/18/2014 ANNUAL ENERGY USE SUMMARY TDV I<Btu/ft2- r (S) 187 deg Ext. Walls/Roof Wall Area r Space Heating 5.06 5.64 -0.58 Space Cooling 52.98 44.75 8.24 Fans 10.57 13.89 -3.32 Domestic Hot Water 3.67 2.36 1.32 Pumps 0.00 0.00 0.00 Totals 72.30 66.64 5.66 Percent Better Than Standard: Fenestration Average U -Factor: 7.8% I BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Front Orientation: (S) 187 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 2,526 427 Fuel Available at Site: Natural Gas (M 2,432 285 Raised Floor Area: 0 (N) 2,311 717 Slab on Grade Area: 8,585 (E) 3,149 462 Average Ceiling Height: 14.2 Roof 8,585 0 Fenestration Average U -Factor: 0.51 TOTAL: 1.892 Average SHGC: 0.39 Fenestration/CFA Ratio: 20.2% REMARKS r' F STATEMENT'OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, Address 77-085 Michigan Drive Name Tim Scott 2/182014 City/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Sinnprl nate The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and -worksheets, with the specifications, and with any other calculations submitted with this permit application, and req"ogriizes-tIZR compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation qua�ityfa{ntd1rbullding envelop ese alincrequire installer testing and certification and field verification by an approved HERS rater.01'r`, 8:. (`/i Designer or Owner (per Business & Professions Code)�,� %i,� DFPT Company STRACTS, Inc. F.�i Cit JTF (fC Address 550 S. Oleander Name Anton Marinkovich TioiV Cit /State2i Palm Springs, CA 92264 BATF y p Phone (760) 636 8951 , Sig »� BY License # Date Reg: 213-NO09641BB-000000000-0000 Registration Date/Time: 2013/12/26 19:35:58 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/18/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 2/20/2014 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Huffman Residence Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1211812014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,452 0.025 R-38 0 0 New 4.2.1-A21 Master Bedroom Wall 165 0.069 R-21 7 90 New 4.3.1-A6 Master Bedroom Wall 176 0.069 R-21 52 90 New 4.3.1-A6 Master Bedroom Wall 105 0.069 R-21 1 97 90 New 4.3.1-A6 Master Bedroom Wall 242 0.069 R-21 187 90 New 4.3.1-A6 Master Bedroom Wall 342 0.069 R-21 277 90 New 4.3.1-A6 Master Bedroom Wall 77 0.069 R-21 322 90 New 4.3.1-A6 Master Bedroom Slab 988 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Slab 465 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Roof 1,781 0.025 R-38 0 0 New 4.2.1-A21 Casita Office Bed 4 & 5 Wall 467 0.069 R-21 90 New 4.3.1-A6 Casita Office Bed 4 & 5 Wall 427 0.069 R-21 90 New 4.3.1-A6 Casita Office Bed 4 & 5 Wall 483 0.069 R-21 90 New 4.3.1-A6 Casita Office Bed 4 & 5 Slab 1,467 0.730 None Z277, 180 New 4.4.7-A1 Casita Office Bed 4 & 5 Slab 315 0.730 None 180 New 4.4.7-A1 Casita Office Bed 4 & 5 Roof 561 0.025 R-38 0 New 4.2.1-A21 Casita Office Bed 4 & 5 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 10.0 0.510 NFRC 0.39 NFRC 7 New. traditional Windows & Doors Master Bedroom 2 Window 10.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Master Bedroom 3 Window 4.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Master Bedroom 4 Window 4.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Master Bedroom 5 Window _ 4.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors_ Master Bedroom 6 Window' 'N14.0 0.510 NFRC ,o ;-t' 0.39 NFRC!,, ` V7 New 4r traditional Windows'& Doors 1, Master Bedroom 7 Window, 160.0 0.510 NFRC J 0.39 ''NFRC 52 New, traditional, Windows & Doors Master Bedroom 8 9 Window Window 6.0 :0.510, NFRC F 4.0 /0.510 NFRC 0.39 NFRC - -4187 New..,L,}f traditional Windows & Doors Master Bedroom 0.39 NFRC, 1 187 New-,% traditional Windows & Doors 1. Master,Bedroom.,, few 10 Window d 14.0 t , 0.510 NFRC ' 0.39 NFRC ,187 New., traditional Windows'& Doors r Master Bedroom - 11 WindowsO f %_4.0 :.0.510 NFRC r.' "0.39 NFRC `-v-if_--' 187 New traditional Windows &'Doors` - , Master Bedroom lia 12 Window 10.0 0.510 NFRC " 0.39 NFRC 277 New traditional Windows & Doors Master Bedroom 13 Window 10.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Master Bedroom 14 Window 6.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Master Bedroom 15 Window 28.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Master Bedroom 16 Window 10.0 0.510 NFRC 1 0.39 NFRC 277 New traditional Windows & Doors Master Bedroom (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin H t Wd Len H t LExt RExt Dist Len I Right Fin H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 ' Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Buq Screen 0.76 1 `✓; i ~ (-)r- 11 Bug Screen 0.76 LSI 11 rte,, ," ^-1 (_4 fit 12 Bu Screen 0.76 ""�' v+a ; C,;_* ,� " ` � �+ ► "01A 13 Bug Screen 0.76 1 0 tz) lr�- ' 'p 14 Bug Screen 0.76 F:n,, ,Z 1_ tJ { jti 15 IBug Screen 0.76 16 JBug Screen 0.76 SATE SY EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014-02-18T14:24:44 ID: a e 6 of 12 Reg: 213-N0096418B-000000000-0000 Registration Date/Time: 2013/12/26 19:35:58 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/18/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 2/20/2014 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project NameBuilding Huffman Residence Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/18/2014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 311 0.069 R-21 187 90 New 4.3.1-A6 Casita Office Bed 4 & 5 Slab 561 0.730 None 0 180 New 4.4.7-A1 Casita Office Bed 4 & 5 Roof 2,114 0.025 R-38 0 0 New 4.2.1-A21 Kitchen Great Wall 269 0.069 R-21 7 90 New 4.3.1-A6 Kitchen Great Wall 389 0.069 R-21 97 90 New 4.3.1-A6 Kitchen Great Door 24 1.450 None 97 90 New 4.5.1-A1 Kitchen Great Wall 126 0.069 R-21 187 90 New 4.3.1-A6 Kitchen Great Wall 354 0.069 R-21 277 90 New 4.3.1-A6 Kitchen Great Slab 1,488 0.730 None 0 180 New 4.4.7-A1 Kitchen Great Slab 626 0.730 None 0 180 New 4.4.7-A1 Kitchen Great Roof 904 0.025 R-38 0 0 New 4.2.1-A21 Morning Catering Wall 467 0.069 R-21 7 90 New 4.3.1-A6 Morning Catering Wall 778 0.069 R-21 97 90 New 4.3.1-A6 Morning Catering Wall 96 0.069 R-21 187 90 New 4.3.1-A6 Morning Catering Slab 161 0.730 None 0 180 New 4.4.7-A1 Morning Catering Slab 1,504 0.730 None 0 180 New 4.4.7-A1 IMorning Catering FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 28.0 0.510 NFRC 0.39 NFRC 322 New traditional Windows & Doors Master Bedroom 18 Window 79.2 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Casita Office Bed 4 & 5 19 Window 79.2 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Casita Office Bed 4 & 5 20 Window 5.0 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Casita Office Bed 4 & 5 21 Window _ 8.0 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors_. Casita Office Bed 4 & 5 22 Window: '%t12.5 0.510 NFRC o if 0.39 NFRC; - 187 New traditional Windows & Doors 5, Casita Office Bed 4 & 5 23 Window` "- 8.0 0.510 NFRC : i 0.39 NFRC 277 Newr traditional, Windows & Doors ` Casita Office Bed 4 & 5 24 Window 40.0 .;,0.510 NFRC f 0.39 NFRC __1277 New, . r traditional Windows & Doors Casita Once Bed 4 & 5 25 Window 40.0 10.510 NFRC - 0.39 NFRC r 277 New '% traditional Windows & Doors Casita-Office Bed 4 & 5, 26 Window d /12.5 t 0.510 NFRC 0.39 NFRC .277 New. ; traditional Windows'& Doors_: Casita Office Bed 4 & 5 27 Windowol r L_6.0 -0.'510 NFRC •,` -oO.39 NFRC !�277 New N traditional Windows &Doors Casita Office Bed 4 & 5 28 Window 79.2 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Casita Office Bed 4 & 5 29 Window 72.0 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Casita Office Bed 4 & 5 30 Window 32.0 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Casita Office Bed 4 & 5 31 Window 96.0 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Casita Office Bed 4 & 5 32 lWindow 35.0 0.510 NFRC 0.39 NFRC 71 New traditional Windows & Doors Kitchen Great (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 L .; 26 Bug Screen 0.76 N pr ,,, � rJ ' t _.�9, 27 Bug Screen 0.76 UIIWI ; N 28 Bug Screen 0.76 z I r npm- - 29 Bug Screen 0.76 30 Bug Screen 0.76 'LTi (,'( )fvc"_!= 31 JBug Screen 0.76 N " ` ' V r✓ Viiii11 32 JBug Screen 0.76 i nr1- EnergyPro, 5.1 by EnergySoft User Number: 6712 RunCode: 2014-02-18714:24:44 /D: Pae 7 of 12 Reg: 213-N0096418B-000000000-0000 Registration Date/Time: 2013/12/26 19:35:58 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/18/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 2/20/2014 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Huffman Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1211812014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior. Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,010 0.025 R-38 0 0 New 4.2.1-A21 Bed 2 & 3 Wall 300 0.069 R-21 7 90 New 4.3.1-A6 Bed 2 & 3 Wall 386 0.069 R-21 97 90 New 4.3.1-A6 Bed 2 & 3 Wall 633 0.069 R-21 187 90 New 4.3.1-A6 Bed 2 & 3 Wall 316 0.069 R-21 277 90 New 4.3.1-A6 Bed 2 & 3 Slab 8681 0.730 None 0 180 New 4.4.7-A1 Bed 2 & 3 Slab 1421 0.730 None 0 180 New 4.4.7-A1 Bed 2 & 3 Roof 763 0.025 R-38 0 0 New 4.2.1-A21 2nd floor Wall 217 0.069 R-21 7 90 New 4.3.1-A6 2nd floor Wall 538 0.069 R-21 97 90 New 4.3.1-A6 2nd floor Wall 264 0.069 R-21 187 90 New 4.3.1-A6 2nd floor Wall 576 0.069 R-21 277 90 New 4.3.1-A6 2nd floor FENESTRATION SURFACE DETAILS ID I Type Area U -Factor SHGC4 Azm Status Glazing Ty2e Location/Comments 33 Window 3.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Kitchen Great 34 Window 3.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Kitchen Great 35 Window 3.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Kitchen Great 36 Window 3.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Kitchen Great 37 Window_, ,_ 3.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors_ Kitchen Great 38 Window '225.0 0.510 NFRC ,o 0.39 NFRC 117 New 1. traditional Windows'& Doors N, Kitchen Great 39 Window, 5.0 0.510 NFRC ,r 0.39 'NFRC v 97 New traditional., Windows & Doors E Kitchen Great 40 Window 5.0 -20.510 NFRC i 0.39 NFRC 97 New -.O,', traditional Windows & Doors Kitchen Great 41 Window 5.0 10.510 NFRC 0.39 NFRC 1 97 New I l traditional Windows & Doors 4 Kitchen Great 42 Window 0 jV6.0 1 0.510 NFRC • 0.39 NFRC A 9 7 New, .t ' traditional Windows'& Doors Kitchen.Greattt 43 Window4 c 0, x.6.0 ;,.0.510 NFRC,,..- --!0.39 NFRC rJ 97 New `+- traditional. Windows &'Doors' Kitchen Great SvQ 44 Window 6.0 '0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors ' " Kitchen Great 45 Window 6.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Kitchen Great 46 . Window 7.5 0.510 NFRC0.39 NFRC 277 New traditional Windows & Doors Kitchen Great 47 Window 0.39 NFRC 277 New traditional Windows & Doors 24.0 0.510 NFRC#0.39 Kitchen Great 48 Window 25.0 0.510 NFRC NFRC 277 New traditional Windows & Doors Kitchen Great (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC Hat Wd Ove hang Left Fin Len Hat LExt I RExt Dist Len Right Fin Hat Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 ' Y W' ( /A tl 1 10K 43 Btkq Screen 0.76 44 Bug Screen 0.76 t Y L) 45 Bug Screen 0.76 ) - �-.� E _ 1 tk f r %' 46 Bug Screen 0.76 1 -UR i- - LJ 47 JBug Screen 0.76 ""-rtJl;1 ION. 48 JBug Screen 0.76 uHIE EnergyPro 5.1 by EnergySoft User Number.' 6712 Run Code: 2014-02-18T14:24:44 /D: Pa e 8 of 12 Reg: 213-NO09641BB-000000000-0000 Registration Date/Time: 2013/12/26 19:35:58 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/18/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 2/20/2014 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Huffman Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/18/2914 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC4 Azm Status Glazing Type Location/Comments 49 Window 24.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Kitchen Great 50 Window 80.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Morning Catering 51 Window 24.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Morning Catering 52 Window 3.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Morning Catering 53 Window _ _ 80.0 0.510 NFRC 0.39 NFRC 97 New . traditional Windows & Doors_ Morning Catering 54 Window` N35.0 0.510 NFRC f' 0.39 NFRC -197 New traditional Windows & Doors S Morning Catering 55 Window ' 12.5 0.510 NFRC 1 0.39 'NFRC 97 New traditional; Windows & Doors ` Morning Catering 56 Window 12.5- 20.510 NFRC ' 0.39 NFRC : ,d► 97 New.,,,o, A traditional Windows & Doors Morning Catering 57 Window 24:0 (0.510 NFRC 0.39 NFRC i 97 New 1 + traditional Windows & Doors Morning Catering., , 58 Window ,d )12.5. a,.0.510 NFRC 0.39 NFRC. d97 New. i • traditional Windows'& Doors Morning Catering _ 59 MndowA 1, k20:0 ,-.0.510 NFRC 6= -x0.39 NFRC. 97 New ti. traditional Windows'&'Doors' '; Morning Catenng0 60 Window 6.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Morning Catering 61 lWindow 1 79.2 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Bed 2 & 3 62 . Window I 12.5 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Bed 2 & 3 63Window 1 12.5 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Bed 2 & 3 64 lWindow 1 79.2 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors lBed 2 & 3 (1) LI -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove hanq Left Fin Ri ht Fin Len H t LExt RExt Dist Len Hclt Dist I Len H t 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 58 Bug Screen 0.76 59 Bug Screen 0.76 60 Bug Screen 0.76 61 Bug Screen 0.76 t-,�;� ,, , ti �J'Vq'_-� 62 Bug Screen 0.76 gziI-RI Irk rinK 63 JBug Screen 0.76 64 IBug Screen 1 0.76 () Tc EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014-02-18714:24:44 /D: Page 9 of 12 Reg: 213-N0096418B-000000000-0000 Registration Date/Time: 2013/12/26 19:35:58 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/18/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 2/20/2014 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Huffman Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/18/2014 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 65 Window 12.0 0.510 NFRC 0.39 1 NFRC 97 New traditional Windows & Doors Bed 2 & 3 66 Window 12.5 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Bed 2 & 3 67 Window 12.5 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Bed 2 & 3 68 Window 6.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Bed 2 & 3 69 Window, ,__ 37.5 0.510 NFRC 0.39. NFRC 1 7 New traditional Windows & Doors_ 2nd floor 70 Window: '"x,,10.0 0.510 NFRC J 0.39 NFRC, - V7 New 1- , traditional Windows & Doors ,N, 2nd floor 71 Window $10.0 0.510 NFRC T 0.39 'NFRC 97 New, traditional, Windows & Doors ` 2nd floor 72 Window 4.0--.0.510, NFRC 0.39 NFRC'. .,4 97 New.. o1W traditional Windows & Doors 2nd floor 73 Window 4:0 10.510 NFRC , . 0.39 NFRC r 97 New traditional Windows & Doors 2nd floor 74 Window 4 t,4.0_1,0.510, NFRC 0.39 NFRC 497 New. A traditional Windows'& Doors 2nd floor 1; J1 75 Window,+ r 1.+4.0 0.510 NFRC ti 'X0.39 NFRC; <_W 97 New N4 traditional Windows &'Doois2nd floor'r,'71A 'Vo 76 Window 12.0 0.510 NFRC ' 0.39 NFRC 97 New traditional Windows & Doors 2nd floor (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 65 Bug Screen 0.76 66 Bug Screen 0.76 67 Bug Screen 0.76 68 Bug Screen 0.76 69 Bug Screen 0.76 70 Bug Screen 0.76 71 Bug Screen 0.76 1--�- 72 Bug Screen 0.76--- 73 Bug Screen 0.76 ` ` M �✓ i' LIA (711 11iA f -r 74 Bug Screen 0.76 t�ldf(_I )1`� A. QA r-.-; 75 Bu Screen 0.76 " r- r T L Cpr 76 Bug Screen 0.76 ,ee ff�i N_ uHl - Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-02-18714:24:44 /D: Pae 10 of 12 Reg: 213-NO09641BB-000000000-0000 Registration Date/Time: 2013/12/26 19:35:58 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/18/2014 Electronicallv Siqned at CalCERTS.com by Antnn Marinknvirh Mt-r—ta Tnr 1 0/'>n1')n1n CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Huffman Residence Building Type 0 Single Family ❑ Multi Family ❑ Addition Alone ❑ Existing+ Addition/Alteration Date 2/18/2014 BUILDING ZONE INFORMATION HVAC 1 1 Central Furnace 80% AFUE System Name Zone Name Floor Area ft New Existinq Altered Removed Volume Year Built HVAC 1 Master Bedroom 1,452 20,183 HVAC 5/7- r HVAC 2 & 3 Casita Office Bed 4 & 5 1,781 24,222 1 / Central Furnace Entry Dining 561 7,854 IZJ HVAC 4 Kitchen Great 2,114 34,247 l_ Heating HVAC 5 Morning Catering 1,667 23,338 Ducted HVAC 6 Bed 2 & 3 1,010 14,140 HVAC 4 HVAC 7 2nd floor 763 9.156 1 Ducted System Name I Qty. I Type Distributio Bradford White M -1-75S68 2 Large Gas All Pipes Ins 9,3481 0 CoolingType Min. Eff. Thermostat Type Totals HVAC SYSTEMS New System Name Ot . Heating Type Min. Eff. HVAC 1 1 Central Furnace 80% AFUE HVAC 2 & 3 2 ' Central Furnace 80% AFUE HVAC 4 1 -Central Furnace," 80% AFUE HVAC 5/7- r 1 i Central Furnace V 86% AFUE HVAC 6 . '•r 1 / Central Furnace 80% AFUE r �r t IZJ HVAC, DISTRIBUTION Attic, Ceiling Ins, vented 8.0 System Name l_ Heating Cooling HVAC 1 - Ducted Ducted HVAC 2 & 3 Ducted Ducted HVAC 4 Ducted Ducted HVAC 5 1 Ducted Ducted HVAC 6 1 Ducted Ducted WATER HEATING SYSTEMS Ext. Tank Insul. R- Value System Name I Qty. I Type Distributio Bradford White M -1-75S68 2 Large Gas All Pipes Ins 9,3481 0 CoolingType Min. Eff. Thermostat Type Status Split Air Conditioner 16.0 SEER Setback New Split Air Conditioner 16.0 SEER Setback Newsf Split Air Conditionera 16.5 SEER Setback New S lit Air Conditioner 1 •16.5 SEER Setback New Split Air Conditioner r 16.0 SEER Setback New \ N -. 0-4 Duct 7(,Z V Ducts:fV Duct Location R -Value Tested? Status Attic, Ceiling Ins, vented 8.0 IZJ New Attic, Ceiling Ins, vented 8.0 m New Attic, Ceiling Ins, vented 8.0 New Attic, Ceiling Ins, vented 8.0 IZI New Attic, Ceiling Ins, vented 8.0 m New n Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status 76,000 75 0.82 0.00% n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Hot Water Piping Length ft N O r- 75 5 CITY OF [A .QUI ---- IA Control Qty. FHP Plenum Outside Buried Pip Insul. a Sy tsem Name "rLe Ptah [DiaRn ter Thick. At- ❑ FO - nl o 3y— EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2014-02-18T14:24:44 ID: Pae 11 of 12 Reg: 213-N0096418B-000000000-0000 Registration Date/Time: 2013/12/26 19:35:58 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 2/18/2014 Electronically Signed at CalCERTS.com by Anton Marinkovich (Stracts Inc.) 2/20/2014 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Huffman Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1211812014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existinq Altered Removed Volume Year Built Totals 9,348 0 0 0 HVAC SYSTEMS System Name Qty.' Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 7 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION .1 ,17 � L, 1 1 .4 .1 i .F A, LI System Name r Heating�Cooling Duct,?C.-' V Ducts"' Q Duct Location R Value Tested? Status HVAC 7 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 2 -N Q N Ctem ITU' R Dl's r! c FSName �A S, � Pipe , kfLen ttli I�p'ia NTli Pipe eters Insul. Thick. Qty.FHP Plenum Outside Buried ❑ to P ,P r� 0" ❑ FnI4�-- ❑ N EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-02-18T14:24:44 ID: Page 12 of 12 Reg: 213-NO09641BB-000000000-0000 Registration Date/Time: 2013/12/26 19:35:58 HERS Provider: CalCERTS, Inc BUILDING ENERGY ANALYSIS REPORT PROJECT: Huffman Residence Hideaway Lot. #275-276 La Quinta, CA 92253 Project Designer: STRACTS, Inc. 550 S. Oleander Palm Springs, CA 92264 (760) 636-8951 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77 -085 -Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 CITY OF LA QUINTA BUILDING & SAFETY DEPT. Job Number: APPROVED FOR CONS UCTION Date: DATE —3f2 O 2/18/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. i i This program developed by EnergySoft, LLC—www.energysoft.com. 3.,.> Energ Pro 5.1 by EnergySoft User Number 6712 RunCode: 2014-02-18T14:24:44 ID: 8 I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 15 HVAC System Heating and Cooling Loads Summary 18 Room Load Summary 24 Room Heating Peak Loads 30 Room Cooling Peak Loads 37 Pop c°lvsOVED 'rRu DATE EnergyPro 5.1 by EnergySoft Job Number: ID: ~��''� ry User -Number: 6712 0 • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Huffman Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/18/2014 Project Address Hideaway Lot #275-276 La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 9,348 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ® Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 8,585 Radiant Barrier New Wall Wood Framed R-21 8,503 New Slab Unheated Slab -on -Grade None 8,585 Perim = 627' New Door Opaque Door None 24 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Rear (N) 557.2 0.510 0.39 none none Bug Screen New Rear (NE) 160.0 0.510 0.39 none none Bug Screen New Front (S) 426.9 0.510 0.39 none none Bug Screen New Left (tM 257.0 0.510 0.39 none none Bug Screen New Left (NW) 28.0 0.510 0.39 none none Bug Screen New Right (E) 462.4 0.510 0.39 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 & 3 Ducted Ducted Attic, Ceilin'g7ns-vented- _ 8.0 New HVAC 4 Ducted Ducted Attic, 'Ceiling4ns, entedl ,ij �-� r8 0 , New WATER HEATING G'J�LDP f`,'a IA Ot . Type Gallons Min. Eff J Distribution& , FL -Ty DEPT. Status 2 Large Gas 75 0.82 j All PipesJnsC0Tt� ,W L.LJ ji New UN DATE EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-02-18714:24:44 ID: Page 3 of 47 • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Huffman Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/18/2014 Project Address Hideaway Lot #275-276 La Quinta California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 9,348 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST D Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity f Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 5 Ducted Ducted Attic, Ceiling=Ins _Ker ted 8.0 New HVAC 6 Ducted Ducted Attic, Ceiling lns�Vented1 i 1�--p—� �Y New HVAC 7 Ducted Ducted Attic, Ceiling lns, v'entedr,- Q8—d I � W T A jl New WATER HEATING �" V I Y DEPT. Qty. Type Gallons Min. Eff 110listr4eon, � n ,Status 1 RUCTION r BY__ f EneTyPro5.1 by EnergySoft User Number. 6712 Run Code: 2014-02-18714:24:44 /D: Page 4 of 47 • C PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Huffman Residence 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 2/18/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford White M-1-75S6BN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 988.0 ft2 Covered Slab Floor, 3.500" thick at Master Bedroom HIGH MASS Design - Verify Thermal Mass: 465.0 ft2 Exposed Slab Floor, 3.500" thick at Master Bedroom HIGH MASS Design -Verify Thermal Mass: 1,467.0 ft' Covered Slab Floor, 3.500" thick at Casita Office Bed 4 & 5 HIGH MASS Design - Verify Thermal Mass: 315.0 ft2 Exposed Slab Floor, 3.500" thick at Casita Office Bed 4 & 5 HIGH MASS Design - Verify Thermal Mass: 561.0 ft2 Exposed Slab Floor, 3.500" thick at Entry Dining The HVAC System HVAC 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 1,488.0 ft' Covered Slab Floor, 3.500" thick at Kitchen Great HIGH MASS Design - Verify Thermal Mass: 626.0 ft2 Exposed Slab Floor, 3.500" thick at Kitchen Great The HVAC System HVAC 5 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 161.0 ft2 Covered Slab Floor, 3.500" thick at Morning Catering HIGH MASS Design - Verify Thermal Mass: 1,504.0 ft2 Exposed Slab Floor, 3.500" thick at Morning Catering HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24ANB748158CVX090 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge ora Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ANB748 / 58CVX090 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 & 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ANS760 /58PH""110 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic, testing is required to verify that duct leakage meets the specified criteria. i un � Y n (_ I /. The Cooling System Carrier 24ANB760 / 58PH"'110 includes credit for a 13.0 EER Condensser �:�A certified HERS rater must field verify the installation of the correct Condenser. ji The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or Charge Indicator_Di+pla y If L Fc%6 �n�s,�_ The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagrib'stia itesting;is,equired t verify that duct leakage meets the specified criteria. 6 BY Erie Pro 5.1 by Ene Soft User Number: 6712 RunCode: 2014-02-18714:24:44 /D: Page 5 of 47 0 • C , PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project NameBuilding Huffman Residence Type IZI Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/18/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC 6 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan waft draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 868.0 ft2 Covered Slab Floor, 3.500" thick at Bed 2 & 3 HIGH MASS Design - Verify Thermal Mass: 142.0 ftz Exposed Slab Floor, 3.500" thick at Bed 2 & 3 The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24ANB748 /58CVX090 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 6 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 6 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ANB736 /58PH"045 includes credit for a 12.9 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 7 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 7 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. r� v �r LJA QUIN [A RUILDINC a SArr---ry r-,,, '_vi -1 VUNSTRUCTION DATE BY- EnergyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2014-02-18714:24:44 /D: Page 6 of 47 • C C PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Huffman Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 2/18/2014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 5.06 5.64 -0.58 Space Cooling 52.98 44.75 8.24 Fans 10.57 13.89 -3.32 Domestic Hot Water 3.67 2.36 1.32 Pumps 0.00 0.00 0.00 Totals 72.30 66.64 5.66 Percent Better Than Standard: 7.8% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 187 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 2,526 427 Fuel Available at Site: Natural Gas 2,432 285 Raised Floor Area: 0 (N) 2,311 717 Slab on Grade Area: 8,585 (E) 3,149 462 Average Ceiling Height: 14.2 Roof 8,585 0 Fenestration Average U -Factor: 0.51 TOTAL: 1,892 Average SHGC: 0.39 Fenestration/CFA Ratio: 20.2% REMARKS STATEMENT OF COMPLIANCE This, certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and comple Documentation Author Company Scott Design and Title 24, Inc, 2/18/1014 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation qua lityrq d-buil-envelopedi g envelope -sealing require installer testing and certification and field verification by an approved HERSt�rj Uf` �, QUI�� Designer or Owner (per Business & Professions Code) & SAFETY DEPT, IL STRACTS, Inc. ®V �"- Company FO,R CONST Address 550 S. Oleander Name Anton Marinkovich RUCTInry City/State/Zip Palm Springs, CA 92264 Phone (760) 636-8951DarE Signed License # Date Q„ EnemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2014-02-18714:24:44 ID: V�� ' JPa e 7 of 47 0 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Huffman Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1211812014 OPAQUE SURFACE DETAILS Surface Type Area Ll- Insulation Joint Appendix Factor Cavit Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments Roof 1,452 0.025 R-38 0 0 New 4.2.1-A21 Master Bedroom Wall 165 0.069 R-21 7 90 New 4.3.1-A6 Master Bedroom Wall 176 0.069 R-21 52 90 New 4.3.1-A6 Master Bedroom Wall 105 0.069 R-21 97 90 New 4.3.1-A6 Master Bedroom Wall 2421 0.069 R-21 187 90 New 4.3.1-A6 Master Bedroom Wall 3421 0.069 R-21 277 90 New 4.3.1-A6 Master Bedroom Wall 77 0.069 R-21 322 90 New 4.3.1-A6 Master Bedroom Slab 988 0.730 None 0 180 New 4.4.7-A 1 Master Bedroom Slab 465 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Roof 1,781 0.025 R-38 0 0 New 4.2.1-A21 Casita Office Bed 4 & 5 Wall 467 0.069 R-21 97 90 New 4.3.1-A6 Casita Office Bed 4 & 5 Wall 427 0.069 R-21 187 90 New 4.3.1-A6 Casita Office Bed 4 & 5 Wall 483 0.069 R-21 277 90 New 4.3.1-A6 Casita Office Bed 4 & 5 Slab 1,467 0.730 None 0 180 New 4.4.7-A1 1 Casita Office Bed 4 & 5 Slab 315 0.730 None0 180 New 4.4.7-A1 lCasita Office Bed 4 & 5 Roof 561 0.025 R-38 01 0 New 4.2.1-A21 Casita Office Bed 4 & 5 FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 1 window 10.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Master Bedroom 2 Window 10.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Master Bedroom 3 Window 4.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Master Bedroom 4 Window 4.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Master Bedroom 5 Window 4.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Master Bedroom 6 Window 4.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Master Bedroom 7 Window 160.0 0.510 NFRC 0.39 NFRC 52 New traditional Windows & Doors Master Bedroom 8 Window 6.0 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Master Bedroom 9 Window 4.0 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Master Bedroom 10 Window 4.0 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Master Bedroom 11 Window 4.0 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Master Bedroom 12Window 10.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Master Bedroom 13 Window 10.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Master Bedroom 14 Window 6.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Master Bedroom 15 Window 28.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Master Bedroom 16 Window 10.0 0.510 NFRC 0.39 NFRC 2771 New traditional Windows & Doors Master Bedroom (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Te Window Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right Fin Hat Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 1 10 _Bug Screen 0.76 ► d ! t ] - % -. - `-"'- --, 11 _Bug Screen 0.76 12 Bug Screen 0.76 ` `' c -v n - �� J 13 Bug Screen 0.76 14 Bug Screen 0.76 15 JBug Screen 0.76 1 �`�'�� 1 h' ,•T1�^, 16 JBug Screen 0.76 DATE _--- BY EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-02-18714:24:44 /D: N Page 8 of 47 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Huffman Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1211812014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 311 0.069 R-21 187 90 New 4.3.1-A6 Casita Office Bed 4 & 5 Slab 561 0.730 None 0 180 New 4.4.7-A1 Casita Office Bed 4 & 5 Roof 2,114 0.025 R-38 0 0 New 4.2.1-A21 Kitchen Great Wall 269 0.069 R-21 7 90 New 4.3.1-A6 Kitchen Great Wall 389 0.069 R-21 97 90 New 4.3.1-A6 Kitchen Great Door 24 1.450 None 97 90 New 4.5.1-A1 Kitchen Great Wall 126 0.069 R-21 187 90 New 4.3.1-A6 Kitchen Great Wall 354 0.069 R-21 277 90 New 4.3.1-A6 Kitchen Great Slab 1,488 0.730 None 0 180 New 4.4.7-A1 Kitchen Great Slab 626 0.730 None 0 180 New 4.4.7-A1 Kitchen Great Roof 904 0.025 R-38 0 0 New 4.2.1-A21 Morning Catering Wall 467 0.069 R-21 7 90 New 4.3.1-A6 Morning Catering Wall 778 0.069 R-21 97 90 New 4.3.1-A6 Morning Catering Wall 96 0.069 R-21 187 90 New 4.3.1-A6 Morning Catering Slab 161 0.730 None 0 180 New 4.4.7-A1 Morning Catering Slab 1,504 0.730 None 0 180 New 4.4.7-A1 Mornin Catering FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 17 Window 28.0 0.510 NFRC 0.39 NFRC 322 New traditional Windows & Doors Master Bedroom 18 Window 79.2 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Casita Office Bed 4 & 5 19 Window 79.2 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Casita Office Bed 4 & 5 20 Window 5.0 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Casita Office Bed 4 & 5 21 Window 8.0 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Casita Office Bed 4 & 5 22 Window 12.5 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Casita Office Bed 4 & 5 23 Window 8.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Casita Office Bed 4 & 5 24 Window 40.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Casita Office Bed 4 & 5 25 Window 40.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Casita Office Bed 4 & 5 26 Window 12.5 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Casita Office Bed 4 & 5 27 Window 6.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Casita Office Bed 4 & 5 28 Window 79.2 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Casita Office Bed 4 & 5 29 Window 72.0 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Casita Office Bed 4 & 5 30 Window 32.0 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Casita Office Bed 4 & 5 31 Window 96.0 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Casita Office Bed 4 & 5 32 Window 35.OF 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Kitchen Great (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 {"-- -- -- - 25 Baq Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 �� "-Oif'40 & SAFE -Y n=O- T 28 Bug Screen 0.76 29 Bu Screen 0.76 ' `✓ 30 Bug Screen 0.76 (I ��� AVIV; ° f RW It j 31 Bu Screen 0.76 N N •32 Bug Screen 1 0.761 1Tr ----- BY EnergyPro, 5.1 by EnergySoft User Number., 6712 RunCode: 2014-02-18T14:24:44 ID: Page 9 of 47 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Huffman Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/18/2014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix I Factor Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments Roof 1,010 0.025 R-38 0 0 New 4.2.1-A21 Bed 2 & 3 Wall 300 0.069 R-21 7 90 New 4.3.1-A6 Bed 2 & 3 Wall 386 0.069 R-21 97 90 New 4.3.1-A6 Bed 2 & 3 Wall 633 0.069.R-21 187 90 New 4.3.1-A6 Bed 2 & 3 Wall 316 0.069 R-21 277 90 New 4.3.1-A6 Bed 2 & 3 Slab 868 0.730 None 0 180 New 4.4.7-A1 Bed 2 & 3 Slab 142 0.730 None 0 180 New 4.4.7-A1 Bed 2 & 3 Roof 763 0.025 R-38 0 0 New 4.2.1-A21 2nd floor Wall 217 0.069 R-21 7 90 New 4.3.1-A6 2nd floor Wall 5381 0.069 R-21 97 90 New .4.3. 1-A6 2nd floor Wall 2641 0.069 R-21 187 90 New 4.3.1-A6 2nd floor Wall 576 0.069 R-21 277 90 New 4.3.1-A6 2nd floor FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 33 Window 3.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Kitchen Great 34 Window 3.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Kitchen Great 35 Window 3.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Kitchen Great 36 Window 3.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Kitchen Great 37 Window 1 3.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Kitchen Great 38 Window 225.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Kitchen Great 39 Window 5.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Kitchen Great 40 Window 5.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Kitchen Great 41 Window 5.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Kitchen Great 42 Window 6.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Kitchen Great 43 Window 6.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Kitchen Great 44 Window 6.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Kitchen Great 45 Window 6.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Kitchen Great 46 Window 7.5 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Kitchen Great 47 Window 24.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Kitchen Great 48 Window 25.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Kitchen Great (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Buq Screen 0.76 r' �- 43 Bug Screen 0.76 ----- 44 Bug Screen 0.76 1��� 45 Bug Screen 0.76 46 Bug Screen 0.76 i r-. , ,-� ,t -Lr- f . 47 JBug Screen 0.76VR--lam N 48. JBug Screen 0.76 1-U11 CC jN Tf 31 if 1-rf r� QAT9: .� EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-02-18714:24:44 /D:- -___ JPa a 10 of 47 0 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Huffman Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2118/2014 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 49 Window 24.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Kitchen Great 50 Window 80.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Morning Catering 51 Window 24.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Morning Catering 52 Window 3.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Morning Catering 53 Window 80.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Morning Catering 54 Window 35.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Morning Catering 55 Window 12.5 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Morning Catering 56 Window 12.5 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Morning Catering 57 Window 24.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Morning Catering 58 Window 12.5 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Morning Catering 59 Window 20.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Morning Catering 60 Window 6.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Morning Catering 61 Window 79.2 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Bed 2 & 3 62 Window 12.5 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors Bed 2 & 3 63 Window 12.5 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Bed 2 & 3 64 Window 79.2 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Bed 2 & 3 (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window -Hqt Wd Ove hang Len Hat LExt Left Fin Right Fin RExt Dist Len Hat Dist Len Hat 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 58 Bug Screen 0.76 59 Bug Screen 0.76 I ! 1 A ?-N 60 Bug Screen 0.76 '" `- �*= �- + . f 1 61 Bug Screen 0.76 + i.+eta :z 6Nt L I Y I I PPTI I 62 Bug Screen 0.76 --- --., I I 63 IBug Screen 0.76 ! ` °✓ L 64 JBug Screen 0.76 DATE EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201402-18T14:24:44_ ___- ID: --Page -1 of 47 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R •Project Name Huffman Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/18/2014 OPAQUE SURFACE DETAILS Surface U- T e Area Factor Insulation Joint Appendix Cavitv Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 65 Window 12.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors Bed 2 & 3 66 Window 12.5 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Bed 2 & 3 67 Window 12.5 0.510 NFRC 0.39 NFRC 187 New traditional Windows & Doors Bed 2 & 3 68 Window 6.0 0.510 NFRC 0.39 NFRC 277 New traditional Windows & Doors Bed 2 & 3 69 Window 37.51 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors 2nd floor 70 l4rindow 10.0 0.510 NFRC 0.39 NFRC 7 New traditional Windows & Doors 2nd floor 71 Window 10.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors 2nd floor .72 Window 4.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors 2nd floor 73 Window 4.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors 2nd floor 74 Window 4.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors 2nd floor 75 Window 4.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors 2nd floor 76 Window 12.0 0.510 NFRC 0.39 NFRC 97 New traditional Windows & Doors 2nd floor (1) LI -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 65 Bug Screen 0.76 66 Bug Screen 0.76 67 Bug Screen 0.76 68 Bug Screen 0.76 69 Bug Screen 0.76 70 Bug Screen 0.76 71 Bug Screen 0.76 72 Bug Screen 0.76 73 Bug Screen 0.76 r---- 74 Bug Screen 0.76-- 75 Bug Screen 0.76 76 Bug Screen 0.76 1 UU I L-01 V. '. R. Q A r- •L DATE � BY_ - Pro 5.1 by EnergySoft User Number: 6712 RunCode: 201402-18714:24:44 /D: Pa "e 12 of 47 • • r� U CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Huffman Residence Building Type 1Z Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1 2118/2014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existinq Altered Removed Volume Year Built HVAC 1 Master Bedroom 1,452 20,183 HVAC 2 & 3 Casita Office Bed 4 & 5 1,781 24,222 Entry Dining 561 7,854 HVAC 4 Kitchen Great 2,114 34,247 HVAC 5 Morning Catering 1,667 23,338 HVAC 6 Bed 2 & 3 1,010 14,140 HVAC 7 2nd floor 763 9,156 Totals 9,3481 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 2 & 3 2 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 4 1 Central Furnace 80% AFUE S lit Air Conditioner 16.5 SEER Setback New HVAC 5 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC 6 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R -Value Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 El New HVAC 5 1 Ducted 1 Ducted Attic, Ceiling Ins, vented 8.01 m lNew HVAC 6 1 Ducted Ducted Attic, Ceiling Ins, vented 8.01 m INew WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford White M-1-75S6B 2 Large Gas All Pipes Ins 76,000 75 0.82 0.00% n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft C: 0 Q — _ T �` t�1' ► t l System, Name o �. +Pipe)! , FLen th , t Fipe _Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ 1 FUR CONS -T", 41 ►t TIr,Jyt I ❑ i __. � I ❑ i �. M LEnergyPro I 5.1 by EnergySoft User Number: 6712 Run Code: 2014-02-18T14:24: ID: Pae 13 of 47 • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Huffman Residence Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/18/2014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existina I Altered Removed Volume Year Built Totals 1 9,348 0 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 7 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Ducts Coolin Duct Location R -Value Tested? Status HVAC 7 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New El WATER HEATING SYSTEMS S stem Name Qt . T e Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft C 0 — C$ Ty 0!�'LA BS; sterriiNamej, r n ipesI5 _-Le,n th,� J TPpe _Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ I r-uH UONSTRUCTiin\t I ❑I N ❑ n A Tic I rs I EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014-02-1 8 714:24:44 /D: Pae 14 of 47 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Date uffman Residence 1211812014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. 150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is e ui ed with a with a readilyaccessible operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems>15'psi, meets the requirements.of Standards Table 123-A. "150(0)3A: Insulation is protected from damage, including that due to sunlight, moisture !e ui mentmaintenance .and _wmd. i §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or'is'enclosed •entirely inj conditioned space. i r' •'- ° - ` r r ° / C "1 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Ratin Cana Certification,'Cor oration. DATE EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-02-18T14:24:44- 1D.-_ Page 15 of 47 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date uffman Residence 2/18/2014 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Liqhting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, ad -utility rooms are high efficacy and controlled by a manual -on occupant sensor. ,NMa W ,, _ §150(k)9: Permanently installed lighting that is internal to cabinets shall use no hl&e"than X26,atts 6fjpw,er per if e,Afoot of illuminated cabinet. Buil nft G , o A , r-rr rte — ., - L L.,LF 1. APPROVED FOR CONSTRUCTION EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014024"8 nl4 'V-44—_0 , BY__ Page 16 of 47 4 4 r - L_ MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date uffman Residence 2/18/2014 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130 131 134 and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. OF I�� QUINTA I"�G &SAA ETY DEBT. -'Ir �v��� [DATE FOR CONSTRUCTIOV l3Y EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-02-18T14:24:44 /D: Page 17 of 47 4 r - HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name uffman Residence Date 2/18/2014 System Name HVAC 1 Floor Area 1,452 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 1,017 o COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 19,492 1,417 359 20,157 Total Output Btuh 89,000 0 Output Btuh/s ft 61.3 918 769 Cooling System 0 0 Output perSystem 46,000 0 0 0 0 Total Output Btuh 46,000 2,480 1,417 -2,480 Total Output Tons 3.8 918 769 Total Output Btuh/s ft 31.7 Total Output s ftfTon 378.8 23,809 19,216 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 24ANB748 / 58CVX090 34,993 5,474 89,000 Airflow cfm/s ft 1.10 Airflow cfm/Ton 417.4 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 34,993 5,474 Aug 3 PM 89,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 70 OF 70 OF 122 OF Heating Coil Supply Fan 1,600 cfm 4 123 OF 123 OF ROOM 70 OF I COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 79 / 64 OF 79/64°F 58/57°F 59/57°F !990' H 11 n ' / �-p- /� c CITY Cooling Coil Supply Fan C 9 t T O F UN QUI 1 �] 6 A60 / 58 OF 1,600 cfm BUILDING u&�.�SAF`E/ DQESIM, APPi 1i4-7t40U®/ 9 FOR CONSTRUCTION 78�/ 64 OF DATE BY EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014-02-18714:24:44 /D: Page 18 of 47 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Huffman Residence Date 2/18/2014 System Name HVAC 2 & 3 Floor Area 2,342 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL COOLING CFM Sensible Total Room Loads 1,593 31,095 Return Vented Lighting 0 Return Air Ducts 1,465 Return Fan 0 Ventilation o 0 Supply Fan 4,960 Supply Air Ducts 1,465 TOTAL SYSTEM LOAD 38,985 PEAK I COIL HTG. PEAK Heating System Latent CFM Sensible Output perSystem 89,000 2,163 599 33,747 Total Output Btuh 178,000 Output Btuh/s ft 76.0 1,288 Cooling System 0 Output per System 46,000 0 0 0 Total Output Btuh 92,000 2,163 -4,960 Total Output Tons 7.7 1,288 Total Output Btuh/s ft 39.3 Total Output s ft/Ton 305.5 31,363 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 3,200 Carrier 24ANB748 / 58CVX090 70,372 10,264 178,000 Airflow cfm/s ft 1.37 Airflow cfm/Ton 417.4 Outside Air % 0.0% Total Adjusted System Output 70,372 10,264 178,000 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3M Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 70 OF 70 OF 122 OF 123 OF f Cd r+ i Heating Coil Supply Fan 123 OF 3,200 cfm ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 78/64°F 78/64°F 58/57°F 59/57°F c QL ! Cooling Coil Supply Fan BUILDING & SAFETY DEF670/ 57 OF 3,200 cfm �y P P � 0 r— /�, 46.8 °io ROOM FO) CONSTB i 7i Kl 78/64°F _ UA I t BY_ EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-02-18T14:24:44 /D: Page 19 of 47 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name uffman Residence Date 2/18/2014 System Name HVAC 4 Floor Area 2,114 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,306 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 26,252 2,172 590 26,169 Total Output Btuh 89,000 0 Output Btuh/s ft 42.1 1,237 999 Cooling System 0 0 Output perSystem 58,000 0 0 0 0 Total Output Btuh 58,000 1,675 2,172 -1,675 Total Output Tons 4.8 1,237 999 Total Output Btuh/s ft 27.4 Total Output s ft/Ton 437.4 1 30,400 26,492 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANB760 / 58PH"110 44,343 6,632 89,000 Airflow cfm/s ft 0.95 Airflow cfm/Ton 413.8 Outside Air % 0.0% Total Adjusted System Output 44,343 6,632 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 89,000 F Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 70 OF 70 OF 111 OF 112 OF Heating Coil Supply Fan o 2,000 cfm 112 F ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 79/64°F 79/64°F 58/57°F 59/57°F [. A Q # 1 I i. i� /� �1517 Supply Fan vY iJ i(1 V /"� o Cooling Coil 2,000 cfm BUILDING' & SAF -TY DEp�9F APF4 z °// BOOM FOR C;ONS'TR t✓ I !ON 78/ 11 64 OF DATE __ gy EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 201402-18714:24:44 ID: Page 20 of 47 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name uffman Residence Date 2/18/2014 System Name HVAC 5 Floor Area 1,667 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,254 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 25,582 1,397 476 21,213 Total Output Btuh 89,000 0 Output Btuh/s ft 53.4 1,205 810 Cooling System 01 0 Output Per System 58,000 0 0 0 0 Total Output Btuh 58,000 1,675 1,397 -1,675 Total Output Tons 4.8 1,205 810 Total Output Btuh/s ft 34.8 Total Output s ft/Ton 344.9 29,667 21,158 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANB760 / 58PH"110 44,902 5,831 89,000 Airflow cfm/s ft 1.20 Airflow cfmfTon 413.8 Outside Air % 0.0% Total Adjusted System Output 44,902 5,831 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 89,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 70 OF 70 OF 111 OF 112 OF Heating Coil Supply Fan 2,000 cfm 112 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 79/64°F 79/64°F 57/56°F 58/57°F + �!J� �.A. UUri�l ! c BUILDING & SAFETY DEF' OF Cooling Coil Supply Fan 5�,`57 2,000 cfm AP ��p� � FOR 0,DQNO3T IOM 78/64°F nnTc EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2014-02-18714:24:44 ID: Page 21 of 47 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Huffman Residence System Name HVAC 6 Date 2/18/2014 Floor Area 1,010 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 792 15,485 Return Vented Lighting 0 Return Air Ducts 730 Return Fan 0 Ventilation 0 0 Supply Fan 2,480 Supply Air Ducts 730 TOTAL SYSTEM LOAD 1 19,424 PEAK I COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 89,000 1,047 335 18,864 Total Output Btuh 89,000 Output Btuh/s ft 88.1 720 Cooling System 0 Output per System 46,000 0 0 0 Total Output Btuh 46,000 1,047 -2,480 Total Output Tons 3.8 720 Total Output Btuh/s ft 45.5 Total Output s ft/Ton 263.5 17,824 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 24ANB748 / 58CVX090 35,210 5,097 89,000 Airflow cfm/s ft 1.58 Airflow cfm/Ton 417.4 Outside Air % 0.0% Total Adjusted System Output 35,210 5,097 (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK Aug 3P ml 89,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 70 OF 70 OF 122 OF 123 OF Heating Coil Supply Fan 123 OF 1,600 cfm ROOM 70 OF 4 COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 78/64°F 78/64°F 58/57°F 59/57°F �; Nf �w�� l -61NTA Cooling Coil Supply Fan QUILDING & SAFETY DEPT. 60 / 57 OF 1,600 cfm APP P PP, 46��7 °o� FOR cONsrRuc �OOM , Y8/I640F p� TE ---__ BY 1 EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2014-02-18T14::2-4:444 ID: Page 22 of 47 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name uffman Residence System Name HVAC 7 Date 2/18/2014 Floor Area 763 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 265 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 71,000 9,237 639 114 10,121 Total Output Btuh 71,000 0 Output Btuh/s ft 93.1 435 386 Cooling System o 0 Output per System 37,2001 0 0 0 0 Total Output Btuh 37,200 694 435 1 10,801 639 -694 Total Output Tons 3.1 386 Total Output Btuh/s ft 48.8 Total Output s ft/Ton 246.1 10,199 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Carrier 24ANB736 / 58PH"045 29,424 0 71,000 Airflow cfm/s ft 1.05 Airflow cfm/Ton 258.1 Outside Air % 0.0% Total Adjusted System Output 29,424 0 71,000 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 70 OF 70 OF 153 OF 154 OF I C�� ri G Heating Coil Supply Fan 800 cfm 153 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0cfm 79 / 58 OF 79/58°F 44/42°F 45/43°F c �.� �i ��-- -- Cooling Coil Supply Fan t LA Qh�� 5 / 43 OF Eer1 800 cfm BUILDING & S%�FELk6bm APPR i/ N ° FOR CGNSTRucrjoN N 8 /I57 F ©ATE BY EnergyPro 5.1 by EnergySofi User Number: 6712 Run Code: 20 14-02-1 8 714:24:44 /D: Page 23 of 47 • • ROOM LOAD SUMMARY Project Name Date Huffman Residence 211812014 System Name Floor Area HVAC 2 & 3 2,342 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible I Latent CFM Sensible Latent CFM Sensible Casita Office Bed 4 & 5 Casita Office Bed 4 & 5 1 1,071 20,914 1,493 1,071 20,914 1,493 407 22,942 Entry Dining 1 521 10,181 670 521 10,181 670 192 10,804 Total includes ventilation load for zonal EnemyPro 5.1 by EnemySoft User M FGA PAGE TOTAL TOTTA_WTE _ 1 593` ��Y 1 Q95''fj(2,1�63 BY 599 33,747 1, 593 31 , 095 2,163 1;599 33, 747 • • ROOM LOAD SUMMARY Project Name Date Huffman Residence 2/18/2014 System Name Floor Area HVAC 4 2,114 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM Sensible I Latent CFM I SensibleLatent CFM I Sensible Kitchen Great Kitchen Great 1 1 1,306 26,2521 2,172 1,3061 26,252 2,172 5901 26,169 Total includes ventilation load for zonal "'-LJ"Ju & SAFETY ,b ..- a/fit 'I �fil PAGE TOTAL 1,306 26,252"vV 2,17l2 59011 26,169 TOTAL j DAT,11- _1,306 26,252 J 2,172 590 26,169 u J • • ROOM LOAD SUMMARY Project Name Date Huffman Residence 2/18/2014 System Name Floor Area HVAC 5 1,667 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM I Sensible I Latent CFM ISensible Latent CFM I Sensible Morning Catering Morning Catering 1 1 1,2541 25,5821 1,397 1,2541 25,5821 1,397 4761 21,213 Total includes ventilation load for zonal EnemyPro 5.1 by EnemySoft User N PAGE TOTAL TOTAL' ILE[I rn - 1,254 ''/, V' 1 ��//97 25,582 1,397 1ON476 121,213 T 1,254 25,582 1,397 476 1 21,213 DA. ��_ BY • • 0 ROOM LOAD SUMMARY Project Name Huffman Residence Date 2/18/2014 System Name HVAC 6 Floor Area 1,010 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM I Sensible Latent CFM Sensible Bed 2 & 3 Bed 2 & 3 1 792 15,485 1,047 792 15,485 1,047 335 18,864 N Y (IF UA Chi If WA 1 cn,-�` bt.6 DING & SA1=FTv r,EnQ includes ventilation load for zonal systems. PAGE TOTAL 1 792 15, 48`f ui r047 � 3351 18, 864 TOTAL'pATE 792 15,4851 1,047 335; 18,864 ---- TOTALJITotal EnerqvPro 5.1 by EnerqySoft User Number. 6712 RunCode: 2014-02-18T14:24:44 ID: --------Page 28 of 47 • • :7 ROOM LOAD SUMMARY Project Name Date Huffman Residence 2/18/2014 System Name Floor Area HVAC 7 763 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible 2nd floor 2nd floor 1 265 9,237 639 2651 9,2371 639 114 10,121 I ' Total includes ventilation load for zonal N PAGE TOTAL TOTAL* 1 N/1' 265 f IrX i,°' 'J9,287 RUs39 j0N114 1 10,121 265 9,237 639 114 1 10,121 UAic�_BY • • ROOM HEATING PEAK LOADS Project NameDate Huffman Residence 2/18/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Floor Area 1,452.Oft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0250 X 0.0690 X 0.5100 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X X to another room CITY 13.90 X 3�0�305 Ceiling Height ACHE FOR X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X I`! AT 'F Btu/hr = 1,597 = 3,361 = 6,867 = 3,533 = = = = = = = = = = = = = = = = = = = = = = = = = = = 15,358 T� -� 4,799 v1:t, I �D - R-38 Roof Attic 1,452.0 44 R-21 Wall 1,107.0 44 traditional Windows & Doors 306.0 44 Slab -On -Grade perm = 110.0 44 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,452 X Area Page Total ®F LAof �r'6Ux,4'Llll4 �T' CONSTR� TOTAL HOURLY HEAT LOSS FOR ROOM — ""'V 20 157 LDATE BY— EnergyPro 5.1 by Energ Soft User Number: 6712 Run Code: 2014-02-18T14:24:44 — ID: —Page 30o 47 C ROOM HEATING PEAK LOADS Project Name7211812014 Huffman Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Office Bed 4 & 5 Floor Area 1, 781.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X TY til S" '� FOR AT 'F Btu/hr = 1,959 = 4,179 = 6,517 = 4,400 = = = = = = = = = = = = = = = = = = = = = = = = = = = 17,055 aa �1 44 � 5,887 X1 1 ' r . R-38 Roof Attic 1,781.0 0.0250 44 R-21 Wall 1,376.6 0.0690 44 traditional Windows & Doors 290.4 0.5100 44 Slab -On -Grade perim = 137.0 0.7300 44 Items shown with an asterisk (') denote conduction Infiltration: 1.001.064 X � Schedule Air Sensible Fraction through an interior surface X 1,781 X Area another room C ----------,page til 13.60 X 0.34-1-)�fi0 Height ACHft. Page Total OF n . �/ �&X,z ��y-T-, 'y AT �""" P COQ � ED TOTAL HOURLY HEAT LOSS FOR ROOM .--1 IUI\J 2,2 942 LATE BY_ I �-- EnergyPro 5.1 by Energ Soft User Number: 6712 Run Code: 2014-02-18714:24:44 /D: Page 31 of 47 0 • ROOM HEATING PEAK LOADS Project Name7211812014 Huffman Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Entry Dining Floor Area 561.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X ,�X_ (�Fy AT *F = = _ _ = = = = = = = = = = = = = = = = = = = = = = = = _ 4.4 Btu/hr R-38 Roof Attic 561.0 0.0250 44 617 R-21 Wall 310.8 0.0690 44 944 traditional Windows & Doors 279.2 0.5100 44 6,265 Slab -On -Grade perim = 35.0 0.7300 44 1,124 through an interior surface X 561 X Area j-'----@ another room F a BUrc_,U>`vG 14.00 X 0.3031-/,60 Height ACH h — �!8,950. I :-4: Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction 0 Fg otal- �� ��UIPVTA a X_r _ Or' U VYT., NRU L— Ceiling TOTAL HOURLY HEAT LOSS FOR ROOM I p T 110,8 4 L BY Energ Pro 5.1 b Energ Soft User Number.' 6712 RunCode: 2 014 02-1 8 714:24.44 ID:--�'�Page] 32 of 47 C • • ROOM HEATING PEAK LOADS Project Name Huffman Residence Date 2/18/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen Great Floor Area 2,114.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 °F Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X APPROVED FOP, AT °F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr R-38 Roof Attic 2,114.0 0.0250 44 2,325 R-21 Wall 1,137.5 0.0690 44 3,453 traditional Windows & Doors 394.5 0.5100 44 8,853 Wood Door 24.0 1.4500 44 1,531 Slab -On -Grade perim = 94.0 0.7300 44 3,019 Items shown with an asterisk (') denote conduction Infiltration: 1.00 1.064 X� Schedule Air Sensible Fraction through an interior surface X 2,114 X Area another room --------_Page CETY ?261' 16.20 X Ei�;. Height ACH Total :3r- ,�u� r� /60, X 6AHAT 19,182 '244Y 44 Y D 1 A 6,988 DFRT- Ceiling TOTAL HOURLY HEAT LOSS FOR ROOM `°" ' nUU I UN 26 169 DATE RV I EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-02-18T14:24:44---- IDi-----�P_age t?3 of 47 C ROOM HEATING PEAK LOADS Project Name Huffman Residence Date 2/18/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Morning Catering Floor Area 1,667.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 904.0 X U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X APPROVED AT 'F c = = = = = = = = = = = = = = = = = = = = = = t Btu/hr R-38 Roof Attic 0.0250 44 994 R-21 Wall 1,340.5 X X 0.0690 44 4,070 traditional Windows & Doors 309.5 0.5100 44 6,945 Slab -On -Grade perim = 115.0 X 0.7300 44 3,694 X X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface to X 1,667 X Area Ceiling 14.00 X another roomFFOR Height P�g�eTot=al F Xc, ,-Q44��= pf IQTr, 15,703 �e5,510 U HT. TOTAL HOURLY HEAT LOSS FOR ROOM "�' f'UIV 21 213 DATE Ry I EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2014-02-1 8 714:24:44 %D' -- Page -34) of 47 I U • r: ROOM HEATING PEAK LOADS Project Name7211812014 Huffman Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Bed 2 & 3 Floor Area 1,010.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X LHS AT OF Btu/hr 44 = 1,111 44 = 4,966 44 = 5,080 44 = 4,368 = = = = = = = = = = - = = = = = = = = = = = = Total 15,525 ASF aan OF LA�'---� aX x,— 441 Al3,338 Lc �F " L--ATf Ut_pT ' PROOVER CnIC-rn ,._. _ R-38 Roof Attic 1,010.0 0.0250 R-21 Wall 1,635.6 0.0690 traditional Windows & Doors 226.4 0.5100 Slab -On -Grade perm = 136.0 0.7300 Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,010 X Area another room"" ---Page CITY 14.00: XE3UdbF31,X60 Height A `� FOR TOTAL HOURLY HEAT LOSS FOR ROOM _ ' ""'t IUIV P8,864 DATE I EnergyPro 5.1 by Energ Soft User Number: 6712 RunCode: 2014-02-18T14:24:44 159---P-age 35 of 47 C�J • • ROOM HEATING PEAK LOADS Project Name Huffman Residence Date 2/18/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd floor Floor Area 763.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X � Cl-PI/ ur,� FOR AT *F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = _a4„-_- ,rinn, Btu/hr R-38 Roof Attic 763.0 X 0.0250 44 839 R-21 Wall 1,594.5 X 0.0690 44 4,841 traditional Windows & Doors 85.5 X 0.5100 44 1,919 X X X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to X 763 X Area Ceiling Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction another room 12.00 X 0.353 Height ACHAPP CS—,PageTotal- F Lr-�j lldA' _ L/ 60 ��X�j SAF AT _),V C'JNSTRU �_ 7.599 J1AJi W p b"x w ��, _2,522 ” ® TOTAL HOURLY HEAT LOSS FOR ROOM it 10-21 llA7E �-_. BY EneiqyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-02-18T14:24:44 /D: Page 36 of 47 • w 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Huffman Residence 2/18/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Outdoor Dry Bulb Temperature 112 T Floor Area 1,452.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Dailv Range: 34 OF Ouaaue Surfaces R-38 Roof Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-21 Wall Orientation (N) (N) (NE) (E) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,452.0 0.0250 56.0 165.0 0.0690 23.9 176.0 0.0690 29.6 105.0 0.0690 32.7 242.0 0.0690 26.8 342.0 0.0690 32.6 77.0 0.0690 29.8 26.6 0.0 24.7 4.0 26.6 0.0 24.7 160.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestratinn fenistration fenistration fenistration fenistration fenistration fenistration fenistration fenistration fenistration Internal Gain Orientation (N) (N) (N) (N) (N) (N) (NE) (S) (S) Shaded Unshaded Btu/hr 2, 033 272 769 158 1 4,2761 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 24.7 10.0 26.6 0.0 24.7 10.0 26.6 0.0 24.7 4.0 26.6 0.0 24.7 4.0 26.6 0.0 24.7 4.0 26.6 0.0 24.7 4.0 26.6 0.0 24.7 160.0 38.9 0.0 24.7 6.0 26.1 0.0 24.7 4.0 26.1 Page Total 1.0 Occupants X 230 Btuh/occ. - 0.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 X 1.16 X 79.45 X 34 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain 1.0 Occupants X Infiltration: 4,771 X 1.16 X 79.45 X 0.00276 Air Sensible CFM ELA AW Us I Y OF LA - 8 M0 .[Bt'uh/o�c -Quvr[ SAFETY DE FOR CONST RUCTION Btu/hr 266 266 106 106 106 106 6,218 157 105 7.438 Btu/hr 230 0 3,342 19,492 Btu[hr 1200 r_ N N ;1,217 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY X X X X X X X X X Project Name X X X X X X X X X CLTD' = = = = = = = = = Date Huffman Residence 0.0 24.7 4.0 2/18/2014 ROOM INFORMATION 24.7 DESIGN CONDITIONS 26.1 Room Name Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,452.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Dailv Range: 34 OF ue Surfaces Orientation Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF = = = = = = = = - 0.0 24.7 4.0 26.1 0.0 24.7 4.0 26.1 0.0 24.7 10.0 46.2 0.0 24.7 10.0 46.2 0.0 24.7 6.0 46.2 0.0 24.7 28.0 46.2 0.0 24.7 10.0 Page Total FPnPctratinn fenistration fenistration fenistration fenistration fenistration fenestration fenestration fenistration Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = - 0.0 24.7 4.0 26.1 0.0 24.7 4.0 26.1 0.0 24.7 10.0 46.2 0.0 24.7 10.0 46.2 0.0 24.7 6.0 46.2 0.0 24.7 28.0 46.2 0.0 24.7 10.0 46.2 0.0 24.7 28.0 37.2 Page Total Btu/hr 0 Btu/hr 105 105 462 462 277 1,293 462 11042 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ.. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.16 X 79.45 X 34 = 3,342 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19,4921 Latent Gain 1.0 Occupants X Infiltration: 4,771 X 1.16 X 79.45 X 0.00276 Air Sensible CFM ELA AW DA '-1 it F QUI �lrLDINC & 200 �Btuh/,occ._ _ [ FuR CONSTRU T C 0 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY 2/18/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Office Bed 4 & 5 Outdoor Dry Bulb Temperature 112 OF Floor Area 1, 781.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Ranqe: 34 OF Opaque Surfaces R-38 Roof Attic R-21 Wall R-21 Wall R-21 Wall Orientation (S) (tM Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,781.0 0.0250 56.0 466.8 0.0690 32.7 427.3 0.0690 26.8 482.5 0.0690 32.6 5.0 26.1 0.0 24.7 8.0 26.1 0.0 24.7 12.5 26.1 0.0 24.7 8.0 46.2 0.0 24.7 40.0 Page Total Items shown with an asterisk (`) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fpnpstratinn fenistration fenistration fenestration fenistration fenestration fenistration fenistration fenistration fenistration Oripntatinn (E) (S) (S) (S) (S) (IM (►M (►M (VV) Shaded Unshaded Btu/hr 1,053 790 1,084 1 5,4201 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = c = = = 0.0 24.7 79.2 47.2 0.0 24.7 79.2 26.1 0.0 24.7 5.0 26.1 0.0 24.7 8.0 26.1 0.0 24.7 12.5 26.1 0.0 24.7 8.0 46.2 0.0 24.7 40.0 46.2 0.0 24.7 40.0 46.2 0.0 24.7 1 12.51 1 46.2 Page Total 3,740 2,071 131 209 327 369 1,847 1.847 1 11,1181 Internal Gain Btu/hr Occupants 0.0 Occupants X 230 Btuh/occ. = 0 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.16 X 97.46 X F 4,099 Air Sensible CFM ELA AT ,- TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM VI I ii C j = n1 trn- =20,914 BU!! prNG Latent Gain 200 @&�PA�FEiY pERt/hr Occupants 0.0 Occupants X gtL��"cc1i.,,JVED N 0 -'I LONSTRUCTION Infiltration: 4,771 X 1.16 X 97.46 X 0.00276 - 1 1 1,493 Air Sensible CFM ELA AW v DATE FOR ROOM • .7 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Huffman Residence 2/18/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Office Bed 4 & 5 Outdoor Dry Bulb Temperature 112 OF Floor Area 1, 781.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr fenistration W 0.01 X 24.7 + 6.0 X 46.2 = 277 X + X — X + X = X + X — X + X — X + X — X + X — X + X — X + X — Page Total 277 Internal Gain Btu/hr Occupants 0.0 Occupants X 230 Btuh/occ. = 0 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.16 X 97.46 X 34 = 4,099 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM _ 20,914 Latent Gain (-:r r � - be dui�1Btu7hr Occupants 0.0 Occupants X d jj� AF-F--T\=/ (�- tl 200 gtu� 0 ,� cY � Infiltration: 4,771 X 1.16 X 97.46 X 0.00276 = OR CO SRU - n r 1,493 �iC, Air Sensible CFM ELA AW v DATE _ TOTAL HOURLY LATENT HEAT GAIN FOR ROOM �— _ 1,1493 _N Ener Pro5.1 b Ene Soft User Number 6712 RunCode: 2014-02-18T14:24:44 /D: Page 40 of 47 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Huffman Residence 2/18/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Entry Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 561.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof Attic (N) 561.0 X 0.0250 X 56.0 = 785 R-21 Wall (S) 310.8 X 0.0690 X 26.8 = 574 X X = X X = X X = X X = X X = X X = X X = Page Total 1,360 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr fenistration (S) 0.0 X 24.7 + 79.2 X 26.1 = 2,071 fenestration (S) 0.0 X 24.7 + 72.0 X 26.1 = 1,882 fenistration (S) 0.0 X 24.7 + 32.0 X 26.1 = 837 fenistration (S) 0.0 X 24.7 + 96.0 X 26.1 = 2,510 X + X - X + X - X + X - X + X - X + X - Page Total 7,300 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ.= 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.16 X 30.70 X 34 = 1,291 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM t----� _ 10,181 Latent Gain -�r- Btu/hr ��� Occupants 1.0 Occupants X p v 200t�Btuh%oi c.��i=� [E� 1 200 EDi Infiltration: 0.70 X = XCFM116 X 470 FOR CONSTRU Air Sensible ELA AOV00276i CTION Dares TOTAL HOURLY LATENT HEAT GAIN FOR ROOM BY 670 EnergyPro 5.1 by EnerqvSoft User Number: 6712 Run Code: 2014-02-18T14:24:44 /O: Pa a 41 of 47 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Huffman Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen Great Outdoor Dry Bulb Temperature Floor Area 2,114.0 ft2 Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 78 OF Outdoor Daily Ranqe: Opaque Surfaces R-38 Roof Attic R-21 Wall R-21 Wall Wood Door R-21 Wall R-21 Wall Orientation (E) (E) (S) Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Date 2/18/2014 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 2,114.0 0.0250 56.0 269.0 0.0690 23.9 389.0 0.0690 32.7 24.0 1.4500 32.7 126.0 0.0690 26.8 353.5 0.0690 32.6 0.0 24.7 3.0 26.6 0.0 24.7 3.0 26.6 0.0 24.7 225.0 Page Total Fenestratinn fenistration fenistration fenistration fenistration fenistration fenistration fenistration fenistration fenistration Orientatinn (N) (N) (N) (N) (N) (N) (N) (E) (E) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 24.7 35.0 26.6 0.0 24.7 3.0 26.6 0.0 24.7 3.0 26.6 0.0 24.7 3.0 26.6 0.0 24.7 3.0 26.6 0.0 24.7 3.0 26.6 0.0 24.7 225.0 26.6 0.0 24.7 5.0 47.2 0.0 24.7 .5.01 1 47.2 Page Total 112 OF 78 OF 34 OF Btu/hr Z960 444 877 1,138 233 794 6,446 Btu/hr 932 80 80 80 80 80 5,990 236 236 7,794 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = 460 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.16 X 115.68 X 34 = 4,865 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9-.._.®„__ 26,252 Latent Gain e'tTyO LA Q�11 � Btu/hr t1 r' 1) h.l ^ o f /` 400 Occupants 2.o Occupants X 200 Btuh/occ.sgFETy - Pi'�� hUE►�-t - Infiltration: 4,771 X 1.16 X 115.68 X 0.00276�� = FOR �Ns�t_d Air Sensible CFM ELA AW I Inc icTION 1 AL HOURLY LATENT HEAT GAIN FOR ROOM • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Huffman Residence 2/18/2014 ROOM INFORMATION I DESIGN CONDITIONS Room Name Floor Area Indoor Dry Bulb T Opaque Surfaces Orientation Kitchen Great Outdoor Dry Bulb Temperature 2,114.0 ft2 Outdoor Wet Bulb Temperature 78 OF Outdoor Dailv Ranae: Area U -Factor CLTD' X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. t. Cooling Load Temperature Difference (CLTD) Fana¢tratinn fenistration fenistration fenestration fenistration fenistration fenistration fenistration fenistration fenistration Orientation Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = 0.0 24.7 5.0 47.2 0.0 24.7 6.0 47.2 0.0 24.7 6.0 47.2 0.0 24.7 6.0 47.2 0.0, 24.7 6.0 47.2 0.0 24.7 7.5 46.2 0.0 24.7 24.0 46.2 0.0 24.7 25.0 0.0 24.7 24.0 Page Total 112 OF 78 OF 34 OF Btu/hr M Btu/hr 236 283 283 283 283 346 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. - 460 Equipment 1.0 Dwelling Unit X 1,600 Btu c 1,600 Infiltration: 1.064 X 1.16 X 115.68 X 34 = 4,865 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM CUIWING & SAFETY DEs I . Latent Gain Btu/hr Occupants 2•o Occupants X FO. B ut h/o7l0VE I 400 i1 R CONSTRUCTION Infiltration: 4,771 X 1.16 X 115.68 X 0.00276 ' _ 11,772 Air Sensible CFM ELA AW LDATE BY TOTAL HOURLY LATENT HEAT GAIN FOR ROOM --i 2 172 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name • Huffman Residence ROOM INFORMATION DESIGN CONDITIONS 2/18/2014 Room Name Morning Catering Outdoor Dry Bulb Temperature 112 OF Floor Area 1,667.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Ranqe: 34 OF Opaque Surfaces R-38 Roof Attic R-21 Wall R-21 Wall R-21 Wall Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 904.0 0.0250 77.0 467.0 0.0690 31.5 777.5 0.0690 43.8 96.0 0.0690 40.2 3.0 31.7 0.0 29.5 80.0 64.1 0.0 29.5 35.0 64.1 0.0 29.5 12.5 64.1 0.0 29.5 12.5 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fanestratinn fenistration fenistration fenistration fenistration fenistration fenistration fenistration fenistration fenistration Internal Gain Orientation (N) (N) (N) (E) (E) (E) (E) (E) (E) Shaded Unshaded Btu/hr 1,740 1,014 2,352 266 1 5,3721 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 29.5 80.0 31.7 0.0 29.5 24.0 31.7 0.0 29.5 3.0 31.7 0.0 29.5 80.0 64.1 0.0 29.5 35.0 64.1 0.0 29.5 12.5 64.1 0.0 29.5 12.5 64.1 0.0 29.5 24.0 64.1 0.0 1 29.5 1 12.511 1 64.1 Page Total nts 0.0 Occupants X 230 Btuh/occ. - ent 0.0 Dwelling Unit X 1,2001 Btu = Infiltration: 1.064 X 1.16 X 91.22 X Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain CITY 0F1 QUINTOccu ants o•o Occupants X �"11)o0l1%-ah&ceAFETY DEF] I APPROVED Infiltration: 4,771 X 1.1s X x1.22 X 0.00276 = FOR CONSTRUCTION Air Sensible CFM ELA AW flnr • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 , BY- Btu/hr 2,540 762 95 5,126 2,243 801 801 1,538 801 14,707 Btu/hr 0 0 3,836 25,582 B,tu/hr 1 1,397 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Huffman Residence. 2/18/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Morning Catering Outdoor Dry Bulb Temperature 112 OF Floor Area 1,667.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OFI Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr fenistration (E) 0.0 X 29.5 + 20.0 X 64.1 = 1,282 fenistration (E) 0.0 X 29.5 + 6.0 X 64.1 = 384 X + X - X + X - X + X - X + X - X + X - X + X - X + X - Page Total 1,666 Internal Gain Btu/hr Occupants 0.0 Occupants X 230 Btuh/occ. = �—Ao Equipment 0.0 Dwelling Unit X 1,200 Btu - Infiltration: 1.064 X 1.16 X 91.22 X 34 = 3,836 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 25,582 Latent Gain rpBEuJhr Occupants 0.0 Occupants X RI;200 gt®cL� ���V I%� 0 Jn16 fI & SAFETY DEPT Infiltration: 4,771 X 1.16 X 91.22 X 0.00276 ! _ )LAPPROVED 1,397 Air Sensible CFM ELA AW FOR CONSTRUCTION TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 11,397 ---- BYE EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2014-02-18714:24:44/D: a e 95 of 47 t , RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Huffman Residence • ROOM INFORMATION DESIGN CONDITIONS Date 2/18/2014 Room Name Bed 2 & 3 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,010.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Dailv Ranae: 34 OF Onaaue Surfaces R-38 Roof Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall Orientation (E) Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,010.0 0.0250 56.0 300.3 0.0690 23.9 386.3 0.0690 32.7 633.0 0.0690 26.8 316.0 0.0690 32.6 24.7 79.2 47.2 0.0 24.7 12.0 47.2 0.0 24.7 12.5 26.1 0.0 24.7 12.5 Page Total FPnP_Strafinn fenistration fenistration fenistration fenistration fenistration fenistration fenistration fenistration Internal Gain Shaded Unshaded Btu/hr 1,414 496 871 1,170 710 1 4,6611 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = c = = = - 0.0 24.7 79.2 26.6 0.0 24.7 12.5 26.6 0.0 24.7 12.5 47.2 0.0 24.7 79.2 47.2 0.0 24.7 12.0 47.2 0.0 24.7 12.5 26.1 0.0 24.7 12.5 26.1 0.0 24.7 6.0 46.2 Page Total 1.0 Occupants X 230 Btuh/occ. 0.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 1.16 X 55.27 X 34 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain 1.o Occupants X Infiltration: 4,771 X 1.16 X 55.27 X 0.00276 = Air Sensible CFM ELA AW 0I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM Btu/hr 2,109 333 590 3,740 567 327 327 277 8,269 Btu/hr 230 0 2,324 15.485 CITY OF LA QUINBtulhr oo- IBtah%locr & SAFETY PEPT. 2 APPROVED FOR CONSTRUCTI • r 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Huffman Residence 1 2/18/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Floor Area Indoor Dry Bulb 1 Opaque Surfaces R-38 Roof Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall 2nd floor Outdoor Dry Bulb Temperature 763.0 ft2 Outdoor Wet Bulb Temperature rature 78 OF Outdoor Daily Range: Orientation (E) (S) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 763.0 0.0250 56.0 216.5 0.0690 23.9 538.0 0.0690 32.7 264.0 0.0690 26.8 576.0 0.0690 32.6 24.7 4.0 47.2 0.0 24.7 4.0 47.2 0.0 24.7 4.0 47.2 0.0 24.7 4.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fanactratinn fenistration fenistration fenistration fenistration fenistration fenistration fenistration fenistration Orientation Shaded Unshaded 112 °F 78 °F 34 OF Btu/hr 1,068 358 1,213 488 1,294 1 4,4211 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = c = = = - 0.0 24.7 37.5 26.6 0.0 24.7 10.0 26.6 0.0 24.7 10.0 47.2 0.0 24.7 4.0 47.2 0.0 24.7 4.0 47.2 0.0 24.7 4.0 47.2 0.0 24.7 4.0 47.2 0.0 24.7 12.0 47.2 Page Total Btu/hr 998 266 189 189 189 567 Internal Gain Btu/hr Occupants 0.0 Occupants X 230 Btuh/occ. Equipment 0Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 1.16 X 41.75 X 34 = C Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9.2371 Latent Gain Btu/hr Occupants 0.0 Occupants X 200 Btuh/occ. = 0 Infiltration: 4,771 X 1.16 X 41.75 'X 0.00276 = 639 Air Sensible CFM ELA AW Y LATENT HEAT GAIN FOR ROOM Sladden Engineering 45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 800 E. Florida Avenue, Hemet, CA 92543 (951) 766-8777 Fax (951) 766-8778 November 20, 2013 Mr. Huffman c/o Stracts, Inc. 550 South Oleander Road Palm Springs, California 92264 Project: Proposed Huffman Residence 53-353 Via Pisa — Lots 275 & 276 The Hideaway La Quinta, California Subject: Geotechnical Update Project No. 544-13294 13-11-521 Ref: Geotechnical Engineering Report prepared by Earth Systems Southwest (ESSW) dated September 22, 2000; File No. 07117-10, Report No. 00-09-772 Report of Testing and Observation During Rough Grading prepared by ESS dated August 28,'2002; File No. 07117-11, Report No. 01-07-718 Report of Testing and Observation During Rough Grading prepared by Sladden Engineering dated October 12, 2003; Project No. 544-2199 Report No. 03-10-647 As requested, we have reviewed the above referenced geotechnical reports as they relate to the design and construction of the proposed custom residence. The project site is located at 53-353 Via Pisa (identified as Lots 275 & 276) within the Hideaway Golf Club development in the City of La Quinta, California. It is our understanding that the proposed residence will be a relatively lightweight wood -frame structure supported by conventional shallow spread footings and concrete slabs on grade. The subject lot was previously graded during the rough grading of the Hideaway project site and was subsequently regraded. The rough grading included over -excavation of the native surface soil along with the placement of engineered fill soil to construct the building pads. The regrading included processing the surface soil along with minor cuts and fills to construct the individual building pads to the current configurations. Some additional over -excavation was performed in areas where the building envelopes were reconfigured.I'he most=recent site@gT-adifkg.—is. I (( ,* F-ry '_'� r A P` ^ n a—r summarized in the referenced Report of Testing and Observations During=RoughLGradingi prepared by Sladden Engineering along with the compaction 6 estt3resultsJNG �'.cc SA 1=TY DEPT. The referenced reports include recommendations pertain structure foundations. Based upon our review of the refere structural values included in the referenced grading rep( remain applicable for the design and construction of foundations. P. 9 'A9E21,emntial tLl Jo, 3, gnstruction�J-i resi !d repo it is r op' ion that the prAept r d n eering November 20, 2013 -2- Project No. 544-13294 13-11-521 Because the lot has been previously rough graded, the remedial grading required at this time should be minimal provided that the building falls within the previously established building envelope. The building area should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted to a minimum of 90 percent relative compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. The allowable bearing pressures recommended in the referenced grading report prepared by Sladden Engineering remain applicable. Conventional shallow spread footings should be bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be utilized if desired. The maximum allowable bearing pressure should be 3000 psf. The recommended allowable bearing pressures may be increased by one-third for wind and seismic loading. Lateral forces may be resisted by friction along the base of the foundations and passive resistance along the sides of the footings. A friction coefficient of 0.50 times the normal dead load forces is recommended for use in design. Passive resistance may be estimated using an equivalent fluid weight of 300 pcf. If used in combination with the passive resistance, the frictional resistance should be reduced by one third to 0.33 times the normal dead load forces. The bearing soil is non -expansive and falls within the "very low" expansion category in accordance with 2010 California Building Code (CBC) classification criteria. Slab thickness and reinforcement should be determined by the structural engineer. We recommend a minimum floor slab thickness of. 4.0 inches. All slab reinforcement should be supported on concrete chairs to ensure that reinforcement is placed at slab mid -height. Slabs with moisture sensitive surfaces should be underlain with a moisture vapor retarder consisting of a polyvinyl chloride membrane such as 10 -mil Visqueen, or equivalent. All laps within the membrane should be sealed and at least 2 inches of clean sand should be placed over the membrane to promote uniform curing of the concrete. To reduce the potential for punctures, the membrane should be placed on a pad surface that has been graded smooth without any sharp protrusions. If a smooth surface can not be achieved by grading, consideration should be given to placing a 1 -inch thick leveling course of sand across the pad surface prior to placement of the membrane. _ Based on our field observations and understanding of local geologic type judged applicable to this site is So, generally described as stiff sl additional coefficients and factors relevant to seismic mitigation for ne the 2010 California Building Code (CBC). conditions, the.soil profit�j il. The/fc;How,ing3presenrts9 U/N?' I constructioy baasse,�up8nT' DEp� FOR CONS R V ED oArE ON _ BY Sladden Engineering November 20, 2013 -3- Project No. 544-13294 13-11-521 The seismic design category for a structure may be determined in accordance with Section 1613 of the 2010 CBC or ASCE7. According to the 2010 CBC, Site Class D may be used to estimate design seismic loading for the proposed structures. The 2010 CBC Seismic Design Parameters are summarized below. Occupancy Category (Table 1604.5): II Site Class (Table 1613.5.2): D Ss (Figure 1613.5.1): 1.508 S1 (Figure 1613.5.1): 0.60g Fa (Table 1613.5.3(1)): 1.0 Fv (Table 1613.5.3(2)):1.5 Sms (Equation 16-36 (Fa X Ss)): 1.50g Sm1 (Equation 16-37 (Fv X Si)): 0.90g SDs (Equation 16-38 12/3 X Sms)):1.00g SD1 (Equation 16-39 (2/3 X Sm1)): 0.60g Seismic Design Category: D In addition, we have sampled the surface soil on the subject lot to determine the soluble sulfate content as it relates to selecting appropriate concrete mix designs. Testing indicates that the site soil is generally considered non- corrosive with respect to concrete. The testing indicated soluble sulfate content of 50 ppm (0.005 percent) that corresponds with the "negligible" exposure category in accordance with ACI 318-08, Table 3. Based upon this, the use of sulfate resistance concrete mixes is not required. If you have questions regarding this letter or the referenced reports, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERING Q` BRETT L. ` Brett L. Anderso y ANDERSON . C45389 Principal Engineer UJ 4 CIVIL ENGNEERINC, SER/gvm sr 91Fi1,- I.;i�il� Copies: 2 / Mr. Huffman 2/ Stracts, Inc. CIe I' ev/!D1 ®& LA QUINT SA E:APpRo �,DEPr OF? ooNs� UC YEF® DATE T/ON sy Sladden Engineering Sladden Engineering 6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 45090 Golf Center Pkwy, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 Date: November 21, 2013 Account No.: 544-13294 Customer: Mr. Huffman c/o Stracts, Inc. Location: The Hideaway, Lots 275/276, 53-353 Via Pisa, La Quinta Sulfate Series Analytical Report Soluble Sulfates Soluble Chloride per CA 417 per CA 422 ppm ppm 50 50 D/jVG aC��1 SAFE�, � OR COOYEb pEP DgTEUC Tlpnl Sulfate 544-1 TABLE 19-A-2—REQUIREMENTS FOR SPECIAL EXPOSURE CO.NDMONS ' MAXIMUM MINIMUMJ'�, NOR/AAL•-WEIGHT AND . WATER-CEMENtMO.US UGNTWEIGNT. - MATERIALS' RATIO- BY.: AGGREGATE CONCRETE EXPOSURE CONDITION WEIGHT,`NORMAL'-WEIGHT• AGG'AEGATE CONCRETE •'Pgl'.: x 0.00689.tor MPa Concrete intended to have low permeability when exposed to water 0.50 4000 Concrele exposed to freezing and thawing in a moist condition or to deicing chemicals WATER-SOLUBLE 0.45 4,500 For corrosion protection for reinforced concrete and exposed to chlorides from deicing Chemicals, salts or brackish water, or—spray—from these sources 0.40 SULFATE (SO) IN SOIL, P RG�NTAGE 5,000 TABLE 19-A-3—REQUIREMENTS.FOR•CONCRETE EXPOSED TO SULFATE-CONTAINING'sr7WTInNs , i ��u� marcnars rano orlugher strength maybexquired for low pern)6bility•or for protection against car Dsion'of embedded items or freezing and thawing (Table 19-A-2). 2Scawatcr. ?Pozzolan that has been determined by test or service record to i tauiing Typc V cement mprnvc sulfate resistance when used in concrete con - 2 -264 CITY ®F BUILDING SAF-- pN7-A EPJ; OF? � Q SO WED STRUCTION DATE �` BY LIGHTWEIGHT NORMAL -WEIGHT :AGGREGATE AGGREGATE CONCRETE Maximum Water- I' 'Normal. WeIght WATER-SOLUBLE Cementltloua and SULFATE MAtarlatV. Ratio,-bq'.. .-,Ughlwelghl' SULFATE (SO) IN SOIL, P RG�NTAGE WHgh4 ght NoArtnel Welate -Ag0ro9ale. Concrete;. pill EXPOSURE BY WEIGHT SULFATE (SOS) IN WATER, pprn CEMENT TYPE Conc etel x 0.00689'for MPa. Negligible 0.00-0.10 0-150 Modcratc2. 0.10-0.20 150-1,500 II, IP(MS), IS OSO• 4,000 (MS) Severe 0.20-2.00 1,5 0.000 V 0.45 4,500 Yery severz Over 2.00 Over 10,000 V plus 0.45 4,500 pozzolan3 I e I— , i ��u� marcnars rano orlugher strength maybexquired for low pern)6bility•or for protection against car Dsion'of embedded items or freezing and thawing (Table 19-A-2). 2Scawatcr. ?Pozzolan that has been determined by test or service record to i tauiing Typc V cement mprnvc sulfate resistance when used in concrete con - 2 -264 CITY ®F BUILDING SAF-- pN7-A EPJ; OF? � Q SO WED STRUCTION DATE �` BY LA QUINTA 5y,1- )3z9 H 13-))-5A) Please verify that soils reports contain all of the above information. In ad* clition, to assure continuity between'the investigation/reporting stage and the execution stage, please use the following checklist to verify that the conclusions and recommendations in the report cover all the required elements. Only then can we be assured that the construction documents address all of the site soil conditions. La Quinta Geotechnical Report Checklist Does the "Conclusions and Recommendations" section of the report address each of the following criteria? "Address" means: (a) the criterion is considered significant and mitigation measure(s) noted, or; (b) the criterion is considered insignificant and explicitly.so stated. Y s No Criterion _® Foundation criteria based upon bearing capacity of natural or compacted soil. ® Foundation criteria to mitigate the effects of expansive soils. ® Foundation criteria based upon bearing capacity. -of natural or --compacted soil. ® Foundation criteria to mitigate the effects of liquefaction. ® Foundation criteria. to mitigate the effects of seismically induced differential settlement. ® Foundation criteria to mitigate the effects of long-term differential settlement. ® Foundation criteria to mitigate the effects of varying soil strength. ® Foundation criteria to mitigate expected total and differential settlement. Any "No" answers to the above checklist should be noted as specific required corrections.®-- �s CITYf .RUIN- 10 BRE SON rn DATE