Loading...
0309-073 (SFD)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9'(commehcing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Cla:! Exp. Date 820066 0513 112r 0/ Date /7 AF . Signature of Contractor OWNER -BUILDER DECLA9�iION.,) I hereby affirm under penalty of perjury that I am exempt from the Contractor.s License Law for the following reason: ( ) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carder c - ,jTAT)?, FU14D Policy No.. 1"166442 (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation -provisions of Section 3700 of the Labor I /Code, I shall forthwith comply with il�b�e �rovi`sions. Date: Applicant - Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer.to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. ,0. Each person upon whose behalf this application is made & e, TTerson at whose request and for whose benefit work is performed under ( I MKL!� any permit issued as a result of this applicaton agrees to, & sh i I Ril demnify & hold hii-rmless the City of La Quinta, its officers, agents an( n ploy 2. Any permit issued as a result of this application becomes ni ladva work is not commenced within 180 days from date of issuE nce of such permit, or cessation of work for 180 days will subject permit tolcantmolqUff I certify that I have read this application and state that the above ihformatio correct. I agree to comply with all City, and State laws relating to the building con struction, and hereby authorize representatives of this City to enter upon tPe above- menti oned prol�ei­00r-iff�pection purposes. I U�� — )4 -4 lisignal'ure (Owner/Agent - Date OF PERMIT# BUILDING PERMIT OX119-073 DATE VALUATION LOT TRACT 745 29894-2 JOB SITE ADDRESS APN .772-55W-0.245 OWNER CONTRACTOR DESIGNER EN51NEER M-EAL FMW=,'Z SMEMSWC ALPHA OWE(IA OMMEDA AIRHA OW&GA 42-829 COOK 9ZRM* 9104 42-829 COOK.Tr #104 PALM T)F18LqZT CA 92260 PALM DraM T CA 92260 (760,)568-1712 Ufflh 2357 USE OF PERMIT SWOU FAMMY DVM.UNG 3FD�PFRNIJIT DOZS NOTINCLUIDE POOL� SPA OR DRIVEWAY APPROAC11,2001 CK. CUSTOM CONSTRUCTION 6,666.00 3F FORCHIPATIO, 600.00 SF 0ARAGEICARI"ORT 11531.00 8F HSTE14ATKIn COST 01r CO-VTSTRUC-11,1014 &57,269.00 PERMIT MJR SUL94ARY CONSTRUCTION FEK 101-000-418-000 S%213.50 PIAV CHECK FEE 101-000-439-318 $1,7w.14 FEE DETIOSIT 101-000-439-318 -Slgoa MECHANICA.1, FFE .101-000-421-000 KLECTRICAL FEE 101-000-420-000 061,43 PLUNiuYNO FE)WI -WO-41.9-000 $263.00 STRONG MOTION FEE - RMID 101-000-241-000 $53.711 ORADINO "-E 101-000-423-000 $15.00 DEVELOPER IMPACT PSE AR7 Im P118LIC PLACES R,eSir 270-000-445-0-00 D 'tJP­T0TK, a)' I 1*8�mut-moll Aff D ]"'" c"TE m-, $8,212.47 IMS PRE-1PATI) FIM 3 41,01W.00 08 2003 T OTAL P'EWff f "�Efq ]DUR VU17.47 LA QUINTA CE DEPT. RECEIPT TA BYC DATE FINALED I INSPECTP, !ON INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVA�$ MECHANICAL APPRO Set Backs Underground Ducts Forms & Footings Ducts Slab Grade fk 0 Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap Framing Z F.A.U. vlylloor Compressor Insulation Vents Fireplace P.L. 7 Db7� Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Dryyvall - Int. -Lath ol Final Final POOLS -SPAS BLOCKWALL APPROVALS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground PIbg. Test Final Gas Piping PLUMBING APPROVAA Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final COMtMENTS' 4W. &;qW4 ce, pet MWW&a )Z4ovS -/,z -o -7 Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp, Use of Power Final Utility Notice (Perm) I /X/ P.O. BOX 1504 APPLU�_ATION ONLY Building 78-495 CALLE TAMPICO Address 00 -JR I VIP 55AOLA QUINTA, CALIFORNIA 92253 Oy ner 1�� 3e, -,,X ." BUILDING: TYPE'CONST.—OCC. GRP. Mailing Address ColdK SV ��\c 10 ti A.P. Number -7 -7 2 C't Zip Tel. ),-�)AlLegal Description Lj, zq.3 -fC6,,_j- 27gq q -9 La Contractor Aciaress L Qt Tel. � �Iy% be ' o vq im see, z'� -,-7 0 -) Lo State Lic. * 5,�)o 01,& City &Classil. eme- I # Cil__' 3 a Arch., Engr., Designer Address Tel. I i Q — I 7760--S�R-nio-_1 6ity - -1 Zip State y1h k,,, 61 -Z? () Lic. #C Jt0q q_S- LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractors License Law for the following reason: (Sec. 7031.5 , Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, pricr to *its issuance also requires (he applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for In Pie alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ('] I as o net of the property, or my employees with wages as their sole compensation, will do ihe wwrk, and the structure is not intended or offered for sale. (Sec. 7044, Buisness, and 0 Professions Code: The Contractor's License Law does not apply to an owner of property who .i,ds 0, improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or imp�o vement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I 1 1, as owner of the property, am exclusively contracting with licensed contractors to con- rlr.cl I he project. (Sec. 7044. Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s� licensed pursuant to the Contractor's License Law.) I1 I am exempt under Sec.—B. & P.C. for this reason Date —Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800. Labor Code.) Policy No. Company n Copy is filed with the city. 0 Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed it the permit is for one hundred dollars (SI00) valuation or less. , I certify that in the performance of thp work- for which this permit is issued, I shall not a L =any person in any manner so as to become subject to the Workers' Compensation California. Date—Owner NOTICE TO APPLICANT., If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shaft be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name— Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration it work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above- mentioned property for inspection purposes. Signature of a0plicaril —Date— Mailing Address City, State, Zip 3!�7__b Sq. Ft. (0 No. Size Stories New,�6, Add C3 Alter 0 Estimated VaIuatiorI1b,,,,7L,,/_,,,-,. No: Dw. Units I Repair 0 Demolition 0 PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Eri�q Infrastruct4re I-) Uy 4 P//IV TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback fr(>-n Rear Prop. Line Side Street Setback from Center Line Side Setback froin Property Line FINAL DATE 1-4SPECTOR Issued by: Date— Permit Validated by: Validation: WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION Coachella Valley Unified School District Us—wrN7, Thermal, CA 92274 r760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID APEA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEEPT: CHECK AI: rNITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Date: — necemher 5. ?003 'Sb Phone No. owner's Name: Project Address: 80-299 Via Pessarn I a Qijinta, rA 922-51 Project Description: cinn'la fain APN: 772-550-035 Tract #: 29294-2- Lot #'s: 245 Type of Development: Residential XXXX Commercial Industrial Total Square Feet of Building Area: fi-fi6fi sq- ft - Certification of Applicant/Owners: The person signing certifies that the above information is correc- and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the ownerfieveloper. &4 Dated: Signature: , ss-ot- -( * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * )" * * Or * * * * * * * -* * * * * * * * * * * * * * * * SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project 17620 65995 Approval Number of Sq.Ft. 6,666 Amount per Sq.Ft. $ 2.19 Amount Collected $ 14,598..54 Building Permit Application Completed: Yes/No By: Carey M. Carlson Asst. Supt., Business Serv. Agreement Existing Prior to 1/1/87 N Not Subject to Fee Requirement Certificate issued by: Elvira-Mattson Signature: 0 1 i ce Techni d an NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90-da3. period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payinent of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees impoised is as herein set forth, whether 7 payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days surts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good --ause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Conpliance. 09/30/02 MV:c/mydocs/devfees/certificate of compliance Oct 02 03 03:07p Butch Seal -A--_ 6 'RECORDING REQUESTED BY: When Recorded Mail Document and Tax Statement To: Jon J. Seal 2092 W. Nantucket Cou'rt Littleton, CO 80120 M 303-794-4437 p.3 U DOC a SIZE 04/22/2003 08:OOA Fee-le.ea PCOR , Page I of 2 Recorded in official Record. SMF County Of Riverside Gary L. or,o Assessor, County Clerk & Recorder 111111 IF 111111111111111111111111111, 11 M S U PAGE SIZE I OA PCOR , NOCOR SMF ML;r-. A R L COPY LONG REFUND WD -10 EXAM AVN: I /Z--'jbU-U.J*-4 I KA UZU-Ubb -o-vr i ni.,> Ljjmr- rum Mm.,LjmUrM':S USE GRANT DEED The undersigned grantor(s) declare(s) Documentary transfer tax is $ -(-' ��- City Transfer Tax is $ 010 T .1 X I computed on full value of property conveyed, or I I computed on full value less value of liens or encumbrances remaining at time of sale, DR I I Unincorporated Area City of La Quinta - FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Seal Furniture & Systems, Inc., a Colorado Corporation hereby GRANT(S) to Seal Office Supply, Inc., a Colorado Corporation the following described real property in the City of La Quinta, County of Riverside, State of California: Lat245, TRACT29894-2, COUNTY OF RIVERSIDE, STATEOF CALIFORNIA, AS PER MAP RECORDED IN BOOK 327, PAGE 56-88 OF MISCELLANEOUS MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. THIS DEED IS BEING RECORDED FOR THE SOLE PURPOSE OF CORRECTING THE VESTING. DATED: April 16, 2003 Seal Furniture & Systems, Inc., a Colorado on STATE OF CALIFORNIA COUNTY OF -Riverside ON A-Pril 16, 2003 before me, J# J. S@al Catherine A. Hammons personally appeared Jon J_ Seal — ------------------- personally known to me (or proved to 19 to be the person(s) whose name(s)Ore subscribed to the within instrument and a k I d d to me that�he/they executed the a'e- cKno�v S Same-U4.L1,1W/h6r1their authorized capacity(ies), and that b<���is/their signature(s) on the instrument the person(s), or the entip) upon behalf of which the person(s) acted, exeq6�d the,instrument. _ , , Witness my hancyarf47offig&I seal. - - - - - - - - - - - - - - CATHSZINE A. HANWONS COMMISSdon # 122M Notcry Pubflc — CcRfcwrdo Wyelde Can* (5my Comm. 15,2M4f RDEUTY NATIONALTITLE INSURANCE COMPANY MAIL TAX STATEMENTS AS DIRECTED ABOVE HAS RECORDED TE INSTRUMENT BY REQV)S -AN A=MMODIATION ONLY AND HAS HI)TUMED FD -213 (Rev 7/36) GRANT DEED 9 FOR RE99LARP AND SUMCIF-0 09 ASM_ _95 IEFFECT UPON TH E TITLE TO ANY REAL PRDPERIY TMT MAY BE DESCPJBED THEREIN. DEC -03-2003 WED 03:14 PM GordonRoss L 10/27/2003 13:33 7603469919 December 3, 2003 0MI114 then mgil Cd FAY NO. 7603417631 DESERT R17.50RT MGMT I HIDEAWAY Gordon Stein 41-945 Boardwalk, SuiteK Palm Desert, CA 92211 RE: Seal — Lot 245/]Fivial Review 02 Dear Mr, Stein: The Hideaway Design Review Committee met on Monday, December I" to review the Revised Final Submittal for Lot 245. The DRC is pleased witb the final outcome and have only a few nunor o)tmonts and ocTrections. Please cal.1 Brook Marshall at 346-1161 to SCt Up IL pre -construction meeting once your building permit has been' issued, Revised plans can be 3ubnlittod at that time for our fi I es. Sincerely, - ND La Quinta Partners, LLC �0 BOX "40 - R 1 -100 AVINUE 53 - LA OQUINTA , CA '.ZF()kNjA , 92.IA3 VX: 760,5?9_57eg . v,,ww,jj,4C3W:Iy;r0jfduh.0r) i I r, e) v t 1, T 1. A N 1) COM PA N ) P. 02 PAGE 01 DEC -03-2003 WED 08:15 PM GordonRoss L 10/27/2003 13:33 7603469918 SCRI - Lat M_ Revised TIM Pis ot litter"tw 3, 2003 FAY NO. 7603417631 DESERT REMORT MGMT F. 0 3 FA(iE 02 The following rWesents the COMITIOnts of the DRC; a prb-ooristructiGn meeting should bc set up prior to the start Of any comtruction. Please indicato building envelope, t"nsition Orta private area, etc. on gU olan& 2.7 Grading and Drainage 0 Note: The building cnvclope was not called imt on. the plan; in the future . please call out the building eli'velOPe, tMOsition area, dc. on all plans. 0 Note: lt OPPMB that 200 cy of dirt will need 19 be imporWd, please be aware that a4jacent lots and/or golf course can not be changed or "spoiled" as a rcsult of imported dirt, 2.8 Drivewsys The plan indicates one point near the street Where the driveway is at,23% -please clarify this "hump" and/or correct the gradinj plan (the driveway gradient must be 12% or I=). 2.13 Planting Per your lc*er seed mix has been approved. However, the proposed planting within t ' he Natural Arm appears very nsid. Tie odge of seed mix I and proposed mix should be loosened to allow for a befter -:ransition of the dem planting to the grast seed mix. Thc committee suggests romoving the header and blend the two areas to eliminate the -line of daftnition". The revised planting plan can be submitted after the stan of construction, but no later than 30 days. 2.16 Li liting 19 Note: Thete is very minimal lighting shown, If change; (additions) tire to bc made in the future they must be apprwred Prior to installation, As a Me� UPlights Mkr be used on five tm'es*(witb two lights per tree), 3.7 Doors and Windows Walls must be double fmmed to allow for windows to fie recessed. Applicadons such as the foam proposed are not acceptable as a featuro tocrettc A recess and resubmit, ed look, Mease revise 3.9 Colors The colors an acceptable as shown on the color board; boWevcr final appmval is rquired in the field When the mock up is completed. Please call to request a site vi* whcn you areready, Your plans have been aPPTOvcd with comments; plena bring tf te revised plans with corrections made to the pte-construction meeting. Only one FWl set and onc. reduced so are required for our files. Sincerely, Hidellwily Design Revjow C,mMittee I \ Certificate 'of Occupancy %J INCORPORATM OF Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the Califomia Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code'and the various ordinances of the City regulating building construction andlor use. BUILDING ADDRESS: 80-299 VIA PESSARO Use classification: SFD Building Permit No.: 0309-073 Occu Occupancy Group: R-3 Type of Construction: V -N Land Use Zone: R -L Owm Owner of Building: SEAL FURNITURE SYSTEMS INC Address: 42-829 COOK STREET #104 City, ST, ZIP: PLAM DESERT CA 92260 By: G. SHOWALTER Date: 04/20/,05 Building Official P OST IN A CONSPICUOUS PLACE V.n # — ��D Permit # L Project Addre=ss: 01 --104 A.P. Number. n j Legal Description: Contracior Address: City, ST, Zip: 1, Telephone: 7&6 5Z i/ / 7/,' State Lic. # : A Y,'? 0 6 6 Arch- Engr, Designer Address: City, ST, Zip: Y, ST, Zip.. Telephone: State Lic. Name of Contact Person: x Telephone # of Contact Person: 76� Submittal Structural Calm tTryuss Calm F g er E Y C -,.n,crgy Calm' F pl.i Flood Plain P121 Grading plan Subcontactor List Grant Deed H -O -A. Approval — ------------ — IN HOUSE:- Phnuing Approval Pub. Wks. Appr Fs —cb w—F, a� City of La Quinta. Building at Safety Di*ion P.O. Box 1504, 78-49S Cane Tampico La Quinta, CA 922S3 - (760) 777-7012 Building Permit ApPlication and Tracking Sheet Mom= f CdV 41," Owner's Name: ow 0 r, jAddress: rov— C City. ity. ST 00�m FTclephone: A/05/ Xproject D*csc:ription: P,4 9J.. City Lic. #: A JS lltA 9;kYa/If �V T& ff _OV - 1-k A pP,,,,,. �,. I,- -of IrIc 7-6 Fzc — I— I Total Permit Fees Construction Type: Occupancy: PrOjeCt type (circle one): New Add'n Alter Repair Demo 01 A)IL cz Z�4 Sq. FL: _5-0 1 # St�ries: FZMaterl Value Of Project: -aQ- APPLICANT: DO NOT WRITE BELOW THIS LINE Rec9d TRACKING FCbe-ck- PtRMIT FEES Plan submitted Item WIN, 4L Amount Reviewed, ready for corrections P120 Check Deposit Called contact Person Plan Cbeck Balance Plans Ocked up ---------- Construction Plans resubmitted A ----------- 2" Review, rea dy for dy hitchanical correctio issue Electrical Called Contact person C,71);e% 'o Plumbing up �AUJ 7Y3W 1 IP1205 picked up A "3(,4, I �j 0 r SALL Plans resubmitted Grading Review, ready for correctionMissue Developer Impact Fee Called Contact person D31C Of Permit issue lltA 9;kYa/If �V T& ff _OV - 1-k A pP,,,,,. �,. I,- -of IrIc 7-6 Fzc — I— I Total Permit Fees TITLE 24 REPORT Title 24 Report for: Lot #245 "The Hideaway" (Lot #245) Via Pessaro La Quinta, CA 92253 Project Designer: Stein & Associates 41-945 Boardwalk, Suite K Palm Desert, CA 92260 (760) 568-3696 Report Prepared By: C.J. MCFADDEN BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 Job Number: 0032.00 Date: 11/3/2003 OF LA�QUINTA CCITy BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTiON '05 By D P, r rE iffhe EnergyPro computer program has been used to perform the calculations summarized in this compliance report. TAs program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 0032.00 User Number. 3665 0 191 Certificate of CornDliance: Residential (Part 1 of 2) CF -1 R Lot #245 "The Hideawav" 11/3/2003 Project Title Date (Lot #245) Via Pessaro La Quinta Project Address BuildingPermit# BREEZE AIR CONDITIONING (760) 346-0855 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 6,666 f? Average Ceiling Height: 10.1 ft Total Conditioned Slab Area: 6,666 f? Building Type: Const. Assembly U -Value (check one or more) Wood Single Family Detached El Addition Single Family Attached 0 Existing Building Multi -Family El Existing Plus Addition Front Orientation: (Northeast) 45 diq Floor Construction Type: FX] Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 Raised Floor Component R-38 Roof (R.38.2xl4.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) (W-2) Slab On Grade Slab On Grade Solid Wood Door FENESTRATION Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) Wood 0.028 Exterior Roof Wood 0.057 Exterior Wall Wood 0.057 Exterior Wall n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Wood 0.387 Exterior Door Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes No Ri _q ht (North) 53.5 0.46 0.38 Bug Screen R1 1:1 -1 E 0 Front (East) 52.2 0.46 0.38 Bug Screen 191 1:1 El 191 Left (Southeast) 99.8 0.46 0.38 - Bug Screen [g] El 0 R] Left (Southeast) 153.0 0.48 0.38 _ Bug Screen 191 El El 191 Left (South) 26.0 0.46 0.38 _ Bug Screen 191 1:1 El 0 Rear (Southwest) 43.6 0.46 0.38 _ Bug Screen 0 Rear (Southwest) 136.0 0.48 0.38 Bu -q Screen 191 Rear (West) 48.5 0.46 0.38 Bug Screen 191 El El z Rear (West) 21.3 0.50 0.40 Bug Screen 191 El El [91 Rear (West)- 145.0 0.48 0.38 Bug Screen 191 0 El El Right (Northwest) 23.8 0.46 0.38 Bug Screen [91 El F-1 [91 Front (Northeast) 58.5 0.50 0.40 Bug Screen 191 [91 Run Initiation Time: 11/03/03 08:21:01 Run Code: 1067876461 EnergyPro 3.1 By EnerqySoft User Number: 3665 Job Number: 0032.00 Page:3 of 41 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Lot #245 "The Hideaway" 11/3/2003 Project Title Date (Lot #245) Via Pessaro La Quinta Project Address BuildinG Permit# BREEZE AIR CONDITIONING (760) 346-0855 Plan CK?ck / Date Documentation Author Telephone Shading Computer Performance 15 Field Chack / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION 63.0 Total Conditioned Floor Area: 6,666 f? Average Ceiling Height: 10.1 ft Total Conditioned Slab Area: 6,666 f? Bug Screen Building Type: 1:1 (check one or more) Right 1XI Single Family Detached El Addition 24.0 D Single Family Attached El Existing Building 0.38 0 Multi -Family El Existing Plus Addition [R1 Front Orientation: (Northeast) 45 deg Floor Construction Type: Y Slab Floor Number of Dwelling Units: 1.00 (Northeast) Number of Stories: 1 F-] Raised Floor IP -1 L BUILDING SHELL INSULATION Const. Component Frame Assembly Location/Commen-.s Type Type U -Value (attic, garage, typical, etc.) FENESTRATION Shadina Devices Type Orientation Area Fenestration Exterior Dverhang Side Fins (SF) U -Factor SHGC Shading Yes No Yes No Front (Northeast) 63.0 0.46 0.38 Bug Screen FK1 1:1 El E Right (North) 24.0 0.48 0.38 Bug Screen [R1 El El [91 Front (Northeast) 38.0 0.48 0.38 Bug Screen FAI 1:1 1:1 0 Front (East) 24.0 0.48 0.38 Bug Screen 191 1:1 0 191 Left (South) 121.0 0.48 0.38 Bug Screen 191 El El El Rear (Southwest) 144.0 0.52 0.45 Bug Screen [g] 1:1 1:1 191 Right (Northwest) 22.5 0.50 0.40 Bug Screen 191 El El [91 Right (Northwest) 24.0 0.48 0.38 Bug Screen N1 1:1 El 1XI 1:1 El El El - 1:1 El 1:1 1:1 1:1 El 1:1 1:1 El E] El El Run Initiation Time: 11103103 08:21:01 Run Code: 1067876461 EnerqyPro 3.1 By EnerqySoft User Number: 3665 Job Number: 0032.00 PaqeA of 41 0 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Lot #245 "The Hideaway" 11/3/2003 Project Title , Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Deslgr� Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments rpntral Furnanp 80% AFUE Ducts Attic 4-2 Setbac k ZONE 1 (Master Suite) - Central Furnace Central Furnarp 80% AFUE - Ducts Attic 80% AFLIE - Ducts Attic 42 4.2 Spthank — Setback — ZONE 2 (Guest Suite 1&2) ZONE 3 iLiving Area) rpntral Furnanp 80% AFLIE - pucts Attic 4.2 Setback ZONE 4 (Guest Suite #3) Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments SDlit Air Conditioner 14 (1 qFFR Mmtq in Affir A 01 q.fh-1' 7t-%Klr- 1 1RA-4 SlDlit Air Conditioner WATER HEATING SYSTEMS Rated 1 Tank Energy Fact.1 1 External Water Heater Water Heater Distribution #in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency - Loss I(%) R -Value A-0. SMITH FIR -S-7-5-930 Small Gas Recirc/Time+Temp— 2 7s nnn 75 053 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btuthr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been zigned by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Stein & Associates Address: 41-945 Boardwalk. Suite K Palm Desert, CA 92260 Telephone: (76WU-3696 Lic. #: VW (Sig (date) Egeic ment Agency N Title/Firm: Address: Telephone: Name: C.J. MCFADDEN Title/Firm: BREEZE AIR CONDITIONING Address: .75-145 ST. CHARLES PLNCE PALM DESERT, CA 92211 Telephone: (760) 346-0855 (signatu f �RK �$ nature/sta I EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. 0032.00 Paae:5 of 41 1 0 0 Certificate of Compliance: Residential (Addendum) CF -1 R Title 111312003 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The DHW System "A.0. SMITH FPS -75-230" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "ZONE 1 (Master Suite)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 453 sqft Exposed Slab Floor, 4.00" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 453 sqft Tile in Mortar Interior Mass, 0.75" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 882 sqft Covered Slab Floor, 4.00" thick at Master Suite The HVAC System "ZONE 2 (Guest Suite 1&2)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -21R) -Verify Thermal Mass: 165 sqft Tile in Mortar Interior Mass, 0.75" thick at Guest Suite 1&2 HIGH MASS Design(see C -2R) -Verify Thermal Mass: 165 sqft Exposed Slab Floor, 4.00" thick at Guest Suite 1&2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 940 sqft Covered Slab Floor, 4.00" thick at Guest Suite 1&2 The HVAC System "ZONE 3 (Living Area)" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 3084 sqft Tile in Mortar Interior Mass, 0.75" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 3084 sqft Exposed Slab Floor, 4.00" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 677 sqft Covered Slab Floor, 4.00" thick at Living Area HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the s sion of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing=se measures on a form CF -611. I Plan I Field The HVAC System "ZONE 1 (Master Suite)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "ZONE 2 (Guest Suite 1&2)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "ZONE 3 (Living Area)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "ZONE 4 (Guest Suite #3)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. I Run Initiation Time: 11/03103 08:21:01 Run Code: 1067876461 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: 0032.00 Page: 6 of 41 Certificate of Compliance: Residential (Addendum) CF -1 R - Lot #245 "The Hideaway" 11/3/2003 =Project Title Date 41 Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. Plan Field The HVAC System "ZONE 4 (Guest Suite #3)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 81 sqft Tile in Mortar Interior Mass, 0.75" thick at Guest Suite #3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 81 sqft Exposed Slab Floor, 4.00" thick at Guest Suite #3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 384 sqft Covered Slab Floor, 4.00" thick at Guest Suite #3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the s ion of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing=e measures on a form CF -6R. F—PI—an-1 —Field I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Paqe:7 of 41 1 0 9 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures [X] 11 50(a): Minimum R-1 9 ceiling insulation. E] §150(b): Loose fill insulation manufacturers labeled R -Value. 1XI*§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). E]*§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. FV_1 §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. 1^1 [X] §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures [X] § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § 1 50(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 1 50(i): Setback thermostat on all applicable heating and/or cooling systems. [XI §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-1 2 external insulation or R-16 combined internal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page:8 of 41 Mandatory Measures Checklist: Residential (Page 21 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach ised. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures 40 whether they are shown elsewhere in the documents or on this checklist only. 0, DESCRIPTION Instructions: Check or Initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) FX] § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CIVIC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL1 81, UL181 A, or UL1 81 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. F� 1114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. FX] 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118 (f): Cool Roof material meet specified criteria Lighting Measures FX_1 §150(k)i: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumenstwatt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. IX -1 §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page:g:of4 �1 �] C omputer Method Summary Thermostat �Part 1 of 3) C -2R I nt 1 =AeJ±deawav" —Zone Type Type 11/3 003 roject Title - saro I a Qu*nta -----Sleep*nq epingStat Date roject Addre s —Sleeping -SleeongStat Building Permit# AIR CONDITIONING Lovwnq (760) 346-0855 _nLa _B_R1=F=71= Documentation Author _Sleep'na Telephone Plan Check/Date Mnnrp . 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.53 2.73 0.79 Space Cooling 34.62 33.66 0.96 Domestic Hot Water 4.27 5.42 -1.14 Totals Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: 42.43 41.82 Mi 1.4% BUILDING ZONE INFORMATION Zone Name _Z0NEJ_(Maste,LSuite) .ZONP-9 'r-ue.sLS_uiteJA2) *7_0NE_3�L1vjng_Area) 7_0NE_4_(Gur,s.tB_u,'te #3) 6,666 ft2 Single Fam Detached (Northeast) 45 deg 1.00 1 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Floor Area Volume RooL_ --L-335 --0-02-8- _3A5_ — 0 -Wall 5 —0-0.57- a _qnL -Wall 35 —0-057- 45 go Wall 5 --o-Q57- ____CxL 90 Wall 15 —0-057 so ____ao_ -Wall 461 --U.57- 135 _90- vv.all 25 —0-057- 135 90 Wall 5 ___0 057- ____180_ —9D Wall ___80 —0-07- 225 ___90 Wall _58- ---D-05Z 270 90 -Wall —5 —Q-0 57- 315 90 Roof— __J_t05 __UZ8_ 345 0 -Wall ____290_ __0_05Z 45 - 90 -Wall 47 0,057 45 go -Wall _____251 —0-05Z 135 90 Wall —39 ___0_G5Z 135 __9D_ -Wall _30- --0-057- 225 ----9D- Wall— —8-1 --0-057- ___225 ---qO Wall 23 —0-05L __2n _9D Wall 177 --- U-57- 315 90 Roo:L__ —aj-6-1 _0_0Z8_ 345 0 -wall 29 —0-0.5Z 0 9() -Wall —50 —0-057- 0 go -Wall 240 —0-0.57- 45 _90 - _wall 191 —0-057 ___A5_ 90 .Door 4 —0-38Z 45 9.0 -Wall ___35 —0-057- 90 9.0 -W.alL— 110 ___0_Q5,7 135 ____90_ -Wall —36 —O -Q57- --Aa ___R0 ill 110 376 Solar Gains Y/N 134 1116 —au.86 --4.696 Floor Construction Type: F_� Raised Floor FX-] Slab Floor Total Fenestration Area: 19.8% Total Conditioned Volume: 67,327 ft 3 Total Conditioned Slab Area: 6,666 ft 2 # of Thermostat Vent Units —Zone Type Type Hgt. Area 020 -----Sleep*nq epingStat n a 017 —Sleeping -SleeongStat n/ 0.5s Lovwnq Love at _nLa —0-07-- _Sleep'na _Sje_ep[wS1aL_ --- A/a Form 3 Reference I' WME .151 -a 14i, VY -4 ILVITF1 I RTATAVA WAM 1.11STAT&A "ff %W4 I il WAMUM,11014 W41.0 14 13 MI - 1. -%I- IMI. A WJ72% I 61 IM C PAO] 011 MI 111! WORN 70NF 3 7QNF 1 Location / Comments EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Paae: 10 of 41 1 Computer Method Summary �Part 1 of 3) C -2R 94r; "Thp Hodeawav" 3.53 2.73 11/3/2003 Project Title Space Cooling 34.62 33.66 Date �kt#245)MaPessarp IqQ,lmnta Domestic Hot Water Building Permit # oject Addr6s _X__ -wall ___0_03Z 180 go Totals 42.43 41.82 BREE7F AIR CC 4G (760) 346-0855 Percent better than Standard: Documentation Author Telephone Plan Check/Date .+-r P 15 Field C -iock/Date ethod (Package or Computer) Climate Zone Floor Construction Type: F-1 Source Energy Use Standard Proposed Compliance Single Fam Detached (kBtu/sf-yr) Design Design Margin Building Front Orientation: Space Heating 3.53 2.73 0.79 Space Cooling 34.62 33.66 0.96 Domestic Hot Water 4.27 5.42 -1.14 _X__ -wall ___0_03Z 180 go Totals 42.43 41.82 0.61 Wall ___4a0_ —G,057- 995 An Percent better than Standard: E 1.4% El BUILDING COMPLIES Total Conditioned Floor Area: 6,666 ft2 Floor Construction Type: F-1 R-aised Floor [XI slab Floor Building Type: Single Fam Detached El RGoL_ ___A65 0,098 345 0 Building Front Orientation: (Northeast) 45 deg Total Fenestration Area: 19.8% Number of Dwelling Units: 1.00 Total Conditioned Volume: 3 67,327 Number of Stories: 1 Total Conditioned Slab Area: 6,666 ft 2 BUILDING ZONE INFORMATION # of ThErmostat Vent Zone Name Floor Area Volume Units —Zone Type Type — Hgt. Area 0 -Wall 197 0057 31.5 go X E: Form 3 Reference R-21 Wall (W-21 2616) _2J_.2x6_1_6)_ R-21 Wall (W.21.26 16) -2) 12,2VWall (YV-21-2 16�' ___ 11 (W-21-2 12� V !L(W-21-2xr, ir) [W-2) 9-38, Roof (R_38_2x14_16) 9YR IW 12-21411all4,11-21 9YR M M W, , . ;N IMARTITURTAY&A Location / Comments I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page: 11 of 41 1 Solar OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y/N _X__ -wall ___0_03Z 180 go 1:1 Wall ___4a0_ —G,057- 995 An IX E -W-a]L— __0_05Z 9 9 s 90 El -Wall 0057 270 go El _Wall —6AI 0,057 315 gn El Wall --i7a n n.9;7 go El RGoL_ ___A65 0,098 345 0 El -Wall ----5& 0-057 0 ____90_ E -Wall 179 n 0_857 45 gn X L ALVaIL— 97 0 n57 go go Wall 209 0,057 135 90 Wall 23 —0-05Z 180 qO _wau_ so 0 057 99r, An Wall 60 0.057 995 go X r -Wall 45 —O -Q57- 315 9f) X E: 0 -Wall 197 0057 31.5 go X E: Form 3 Reference R-21 Wall (W-21 2616) _2J_.2x6_1_6)_ R-21 Wall (W.21.26 16) -2) 12,2VWall (YV-21-2 16�' ___ 11 (W-21-2 12� V !L(W-21-2xr, ir) [W-2) 9-38, Roof (R_38_2x14_16) 9YR IW 12-21411all4,11-21 9YR M M W, , . ;N IMARTITURTAY&A Location / Comments I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page: 11 of 41 1 Computer Method Summary (Part 2 of 3) C -2R Lot #245 "The Hideaway" 11/3/2003 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azrn. Tilt Comments J- VV' aw Right (Noik) 1 0-460 038 0 90 Slarra Pacific clari (I o1F) 70NE 1 2 Window -Front (East) 1.0 0.460 0.38 90 90 Sierra Pacific Clad tLo/E) ZONE 1 3 Window Left (Southea t) 1.0 0.460 0.38 135 90 Sierra Pacific Clad (Lo/E) ZONE 1 4 Window Left (Southea t) 48.0 0.480 0.38 135 90 Sierra Pacific Clad (Lo/E) ZONE 1 5 Window Left (Southea Q 6.3 0.460 0.38 135 90 Sierra Pacific Clad (Lo/E) ZONE 1 6 Window Left (Southea t) 6.3 0.460 0.38 135 90 Sierra Pacific Clad (Lo/E) ZONE I I-- Window Left (Southeast) 6.3 0,460 0.38 135 90 Sierra Pacific Clad (Lo1E) ZONE 1 8 Window Left (Southea t) 6.3 0.460 0.38 135 90 Sierra Pacific Clad (Lo/E) ZONE 1 9- Window Left 1heast) -tSDu 6.3 0,460 0.38 135 90 Sierra Pacific Clad (LoIE) ZONE 1 J -Q Window Left (South) 1.0 0,460 0.38 180 90 Sierra Pacific Clad (Lo/E) ZONE 1 11 Window Rear (Southw st) 21.3 0.460 0.38 225 90 gierra Pacific Clad (Lo/E) ZONE 1 12 Window Rear (Southwest) 63.0 0.480 0.38 225 90 Sierra Pacific Clad (Lo/E) ZONE 1 J -a VV*Ln-dQw---Rear (Southwest) 913 -O-4M 0.38 775 90 84erra Pacific Clad (I o/F) ZONE 1 14 Window Rear (West) 1.0 0.460 0.38 270 90 Sierra Pacific Clad �Lo/E) ZONE 1 15 Window Rear (West) 21.3 0.500 0.40 270 90 Sierra Pacific Clad (Lo/E) ZONE 1 16 Window Rear (West) 24.0 0.480 0.38 270 90 Sierra Pacific Clad (Lo/E) ZONE 1 17 Window Rear (West) 21.3 0.460 0.38 270 90 Sierra Pacific Clad (Lo/E) ZONE 1 18 Window Right (Northwe t) 1.0 0.460 0.38 315 90 Sierra Pacific Clad (Lo/E) ZONE 1 19 Window Front (Northeast) 17.5 0,500 0.40 45 90 Sierra Pacific Clad (Lo/E) ZONE 2 20 Window Front '(Northeast) 17.5 0.500 0.40 45 90 Sierra Pacific Clad (Lo/E) ZONE 2 21 Window Front (Northea t) 5.0 0.460 0.38 45 90 Sierra Pacific Clad (Lo/E) ZONE 2 22 Window Left (Southeast) 2.3 0.460 0.38 135 90 Sierra Pacific Clad (Lo/E) ZONE 2 23 Window Left (Southea t) 45.0 0.460 0.38 135 90 Sierra Pacific Clad (Lo/E) ZONE 2 24 Window Left (Southeast) 15.0 0.460 0.38 135 90 Sierra Pacific Clad (Lo/E) ZONE 2 25 Window Left (Southeast) 48.0 0.480 0.38 135 -90 90 Sierra Pacific Clad (Lo/E) ZONE 2 T6 Window Rear (West) 48.0 0.480 0.38 2-70 Sierra Pacific Clad (Lo/E) ZONE 2 27 Window Rear (West) 24.0 0.460 0.38 270 90 Sierra Pacific Clad (Lo/E) ZONE 2 0T8 Window Right (Northwest) 4.0 0.460 0.38 315 90 Sierra Pacific Clad (Lo/E) ZONE 2 29 Window Right (North) 1.2 0.460 0.38 0 90 Sierra Pacific Clad (Lo/E) ZONE 3 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGQ Hgt. Wd. Len. Hgt. I -Ext. REA Dist. Len. -gt-. Dist. Len. Hgt. 1 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 2 Buq Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 3 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 4 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 5 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 T Bug Screen 0.76 00 00 00 00 0.0 0.0 7 Bug Screen -dug 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 -b-- �ffug Screen -0.76 -0.0 -0.0 -0.0 0.0 0.0 0.0 10 Bug Screen -ffug 0.76 0.0 0.0 0.0 0.0 0.0 0.0 T, Screen Iffug 0.76 0.0 0.0 0.0 0.0 0.0 0.0 T2 Screen -ffug 0.76 0.0 0.0 0.0 0.0 0.0 0.0 i-3 Screen -ffug -0.76 -0.0 -0.0 -0.0 0.0 0.0 -0.0 - - - T4 Screen -dug 0.76 -0.76 040 0.0 0.0 0.-0 -0.0 0.0 - T5- Screen - 0.0 0.0 -0.0 0.0 0.0 0.0 - - T6 -��ug Screen -0.76 - 0.0 0.0 0.0 0.0 0.0 0.0 - - - 17 Bu Screen -ffug 0.76 0.0 0.0 0.0 0.0 0.0 0.0 T8 Screen -dug 0.76 0.0 Yo -0.0 -0.0 -0.0 -0.0 T9 Screen -dug -0.76 -0.0 -0.0 -0.0 -0.0 0.0 0.0 TO Screen -0.76 0.0 0.0 0.0 0.0 0.0 0.0 T, Eug Screen -0.76 - 0.0 0.0 0.0 0.0 0.0 0.0 2-2 6ug screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 23 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 2-4 dug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 25 Buq Screen 0.76 0.0 0.0 040 0.0 0.0 0.0 26 Bug Screen -dug 0.76 0.0 0.0 0.0 0.0 0.0 0.0 T7 Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 28 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 29 Bug Screen 0.76 -0.0 0.0 0.0 0.0 Yo -0. 0 I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Pace: 12 of 41 1 Computer Method Summary (Part 2 of 3) C -2R Lot #245 "The Hideaway" 11/3/2003 AM Proiect Tive Date FENESTRATION SURFACES Ll- Act. Glazing Type Location/ # Type Area Factor SHGC Azrn. Tilt Comments -3-0 Wi I - . . (North) in 31 Window Ri6ht (North) 24.0 32 Window Right (North) 24.0 33 Window Right (North) 24.0 34 Window Front (Northeast) 13.5 35 Window Front (Northeast) 1.0 2-6- Window Front (Northeast) 38.0 37 Window Front (Northea t) 21.0 3-8- �Window Front (Northea t) 21.0 -3,q Window Front (East) 1.0 40 Window Front (East) 24.0 41 Window Front (East) 24.0 A2 Window Front ----(East� 940 43 Window Left (Southea t) 1.0 44 Window Left (Southea t) 57.0 45 Window Left (South 1.0 46 Window Left (South 73.0 47 Window Rear (Southwest) 1.0 48 Window Rear (Southwest) 73.0 49 Window Rear (Southwest) 144.0 50 Window Rear (West) 1.0 _5j_ Window Rear (West) 73.0 52 Window Rear (West) 1.2 53 Window Right (Northwest) 1.0 54 Window Right (Northwest) 4.0 5-5 Window Right (Northwe t) 4.0 56 Window Right (Northwest) 4.0 T7 �Vindow Right (Northwest) 22.5 58 Window Right (Northwest) 24.0 INTERIOR AND EXTERIOR SHADING # Exterior Shade TVDe SHGC 0460 n 18 0 qn Sierra Pacific Clad (Lo/E) 0.460 0.38 0 90 Sierra Pacific Clad �Lo/E� 0.480 0.38 0 90 Sierra Pacific Clad (Lo/E) 0.460 0.38 0 90 Sierra Pacific Clad (Lo/E) 0.500 0.40 45 90 Sierra Pacific Clad (Lo/E) 0.460 0.38 45 90 Sierra Pacific Clad (Lo/E) 0,480 0.38 45 go Sierra Pacific Clad (Lo/E) 0.460 0.38 45 90 Sierra Pacific Clad (Lo/E) 0,460 0.38 A5 90 $ierra Pacific Clad (Lo/E) 0,460 0.38 90 go 9ierra Pacific Clad (Lo/E) 0.460 0.38 90 90 Sierra Pacific Clad (Lo/E) 0.480 0.38 90 90 Sierra Pacific Clad (Lo/E) 0,460 0-38 90 90 i -rra Pacific Clad (Lo/E) 0.460 0.38 135 90 Sierra Pacific Clad (Lo/E) 0.480 0.38 135 90 Sierra Pacific Clad (Lo/E) 0.460 0.38 180 90 Sierra Pacific Clad (Lo/E) 0.480 0.38 180 90 Sierra Pacific Clad (Lo/E) 0.460 0.38 225 90 Sierra Pacific Clad (Lo/E) 0,480 0.38 225 90 Sierra Pacific Clad (Lo/E) 0.520 0.45 225 90 Sierra Pacific Clad (Lo/E) 0.460 0.38 270 90 Sierra Pacific Clad (Lo/E) 0.480 0.38 270 90 Sierra Pacific Clad (Lo/E) 0.460 0.38 270 90 Sierra Pacific Clad (Lo/E) 0.460 0.38 315 90 Sierra Pacific Clad (Lo/E) 0.460 0.38 315 90 Sierra Pacific Clad (Lo/E) 0.460 0.38 315 90 Sierra Pacific Clad (Lo/E) 0.460 0.38 315 90 Sierra Pacific Clad (Lo/E) 0.500 0.40 315 90 Sierra Pacific Clad (Lo/E) 0.480 0.38 315 90 Sierra Pacific Clad (Lo/E) Window Overhang Left Fin Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. 30 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 3-1 dug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 32 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 33 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 34 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 J5 Bug Screen 0.76 0.0 0.0 0. 0. 0. 0,0 36 Bug Screen Iffug 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Y7 Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 T8 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 39 Bug Screen -9ug 0.76 0.0 0.0 0.0 0.0 0.0 0.0 4-0- -�-i Screen -ffug 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Screen -dug -0.76 -0.76 -0.0 -0.0 -0.0 0.0 0.0 0.0 T2 Screen '�ug -0.76 0.0 0.0 -0.0 -0.0 0.0 0.0 4-3- Screen 0.0 0.0 0.0 0.0 0.0 0.0 ,�4- Screen -0.76 0.0 0.0 0.0 0.0 0.0 0.0 T5 Screen -0.76 0.0 0.0 0.0 0.0 0.0 0.0 46 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 47 Bug Screen -ffug 0 00 00 00 00 00 0.0 T8 Screen -ffug -0.76 -0.0 -0.0 -0.0 -0.0 0.0 0.0 49- -9-0- Screen '�ug -0.76 0.0 0.0 0.0 0.0 0.0 0.0 Screen 0.76 - 0.0 -0.0 0.0 -0.0 0.0 - 0.0 0.0 0.0 51 6ug Screen 0.76 0.0 0.0 0.0 0.0 52 Bbug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 53 Bug Screen 0.76 -0.0 0.0 0.0 0.0 0.0 0.0 54 0.76 0.0 0.0 0.0 0.0 0.0 0.0 55 -�6- Bug Screen 'bug 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 1057 58 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 7QNF',1 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE Right Fin Dist. Len. Hgt. I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Paqe: 13 of 41 1 Computer Method Summary (Part 2 of 3) C -2R 11/3/2003 Date # Type Overhang Area Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments -5.9 Wjndow--ffight-��st) 91 0460 n 3R -315- AD Sierra Pacjfic Clad (Lo/E) 70NP I 60 Window Right (Northwe t) 2.3 0.460 0.38 315 90 Sierra Pacific Clad (Lo/E) ZONE 3 61 Window Right (Northwe t) 1.2 0.460 0.38 315 90 Sierra Pacific Clad (Lo/E) ZONE 3 62 Window Right (North) 2.2 0.460 0.38 0 90 Sierra Pacific Clad (Lo/E) ZONE 4 63 Window Front (Northea t) 10.0 0.500 0.40 45 90 Sierra Pacific Clad (Lo/E) ZONE 4 64 Window Front (Northea t) 15.0 0.460 0.38 ...45 90 Sierra Pacific Clad (Lo/E) ZONE 4 B5 Window Front (East) 2.2 0,460 0.38 90 90 $*erra Pacific Clad (Lo/E) ZONE 4 66 Window Left (Southeast) 4.0 0.460 0.38 135 90 Sierra Pacific Clad (Lo/E) ZONE 4 -U Window Left (South) 48.0 0,480 0.38 180 90 $ierra Pacific Clad (Lo/E) ZONE 4 68 Window Left (South) 24.0 0,460 0.38 180 90 $ierra Pacific Clad (Lo/E) ZONE 4 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA. Dist. Len. Hgt. Dist. Len. Hgt. 59 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 60 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 61 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 62 Buq Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 63 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 76� Bug Screen 0.76 0.0 010 0. 0. 0. 0.0 65 -6-6- Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Bug Screen -dug 0.76 0.0 0.0 0.0 0.0 -d.--o -0.0 T7 Screen 0.76 0.0 0.0 0.0 0.0 -6-.-o -0.0 6-8 dug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Paw: 14 of 41 1 Computer Method Summary (Part 3 of 3) C -2R Lot #245 "The Hideaway" Type Length 11/3/2003 AN&Project Title VF Slab Perimeter 40 0.76 0.0 0 ZONE Date THERMAL MASS FOR HIGH MASS DESIGN -S.Iab-I?-erimeteL-- 49 Area Thick. Heat Inside Location Type M (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete. HeamMight —A-53 -4-M 9a -Dae, la 0 7QNF 1 / Slah on Grade Tile in Mortar 453 0.75 24 0.67 n/a 0 ZONE 1 / Interior Mass Concrete. Heay)8meight 882 4.00 28 0.98 n/a 2 ZONE 1 / Slab on Grade Tile in Mortar 165 0.75 24 0.67 n/a 0 ZONE 2 /Interior Mass yMeight 165 4.00 28 0.98 n1a 0 ZONE 2 / Slab on Grade -941ah', I:% d =1 Z41101*4 ZK For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 40 0.76 0.0 0 ZONE I -S.Iab-I?-erimeteL-- 49 JQ16 --O-Q 0 7QNF I Slab Perimeter 59 0.76 0.0 0 ZONE 2 -S.I.ab-P-erhnP.teL— 60 -QZ6 —O -Q 0 7QNF 9 -S.Ia Pprimpte.L_ 218 0.76 0.0 0 ZONE 3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location pump, etc.) (AFUE/HSPF)(ducts/aftic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback ZONE 1 (Master Suite) Central Furnace 80% AFUE Ducts in Affic 4.2 Setback ZONE 2 (Guest Suite 1&2) Central Furnace 80% AFUE Ducts in Attic 4.2 Setback ZONE 3 (Living Area) Central Furnace 80.% AFUE Ducts in Affic 4.2 Setback ZONE 4 (Guest Suite #3) Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location heat pump, evap. cooling) (SEER) (attic, etcj R -Value Type Comments -$plit Air Conditioner 14.0 SEE Ducts in Affic 4.2 Setback ZONE 1 (Master Suite) Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback ZONE 2 (Guest Suite 1&2) Split Air Conditioner 14.0 SEER Ducts in Affic 4.2 Setback ZONE 3 (Living Area) Split Ai Conditioner 14.0 SEER Ducts in Attic 4.2 Setback ZONE 4 (Guest Suite #3) WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 TankInsul. Water Heater Water Heater Distribution #in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss Ext. A.0. SMITH FPS -75-230 Small Gas Recirc/Time+Temp--- 2 75,000 75 0.53 n/a 12 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Part 3 of 3) Q -2R Lot #245 "The Hideaway" '11/3/2003 AM& Prolect Title Type Length Factor R -Val- Depth Location Comments Date THERMAL MASS FOR HIGH MASS DESIGN 3 .S1ab-BehnmteL— 26 Area Thick. Heat Slab Perimeter 65 Inside Locabon Type (sD (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete. HeamMeight g4n 40 2A -0M n/a 2 70NF 2 /,Rl;ih on Grade Tile in Mortar 3,084 0.75 24 0.67 n1a 0 ZONE.3 /Interior Mass Concrete. HeamMeight 3,084 4.00 28 0.98 n1a 0 ZONE 3 / Slab on Grade Concrete, HeamMeight — 677 4.00 28 0.98 rVa 2 ZONE 3 /Slab on Grade Iffe, in Mortar — 81 0.75 24 0.67 rkla 0 ZONE4 /Interior Mass PERIMETER LOSSES F2 Insulation Type Length Factor R -Val- Depth Location Comments Slab Perimeter 42 0.76 0.0 0 ZONE 3 .S1ab-BehnmteL— 26 -1116 —O -Q 0 ZONE 4 Slab Perimeter 65 0.76 0.0 0 ZONE 4 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location pump, etc.) (AFUE/HSPF)(ducts/aftic, etc.) R -Value Type Comments Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments WATER HEATING SYSTEMS Ratedl Tank Energy Fact! TankInsul. Water Heater Water Heater Distribution #in Input Cap. or Recovery Standby R -Value System Name Type Type Svst. (Btu/hr) (qal) Efficiercv Loss (%) Ext. For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 11103/03 08:21:01 Run Code: 1067876461 EneEgyPro 3.1 By EnernySoft User Number: 3665 Job Number: 0032.00 Page: 16 of 41 Computer Method Summary (Part 3 of 3) Q -2R Lot #245 "The Hideaway" 11/3/2003 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Lcss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Area Thick. Heat Inside Location Type (sD (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete Hea4weight s A -GO --28 -0-9a nLa- 0 ZONE:A�2h on Grade Concrete, HeamMeight 384 4.00 28 0.98 n/a 2 ZONE 4 /Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location Comments HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location pump, etc.) (AFUE/HSPF)(ducts/aftic, etc.) R -Value Type Comments Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments WATER HEATING SYSTEMS Ratedl Tank Energy Fact! TankInsul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss Ext. For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Lcss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Addendum) C -2R Lot #245 "The Hideaway" 11/3/2003 Proinct Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The DHW System "A.0. SMITH FPS -75-230" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "ZONE I (Master Suite)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 453 sqft Exposed Slab Floor, 4.00" thick at Master Suite HIGH MASS Design(see C-213) - Verify Thermal Mass: 453 sqft Tile in Mortar Interior Mass, 0.75" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 882 sqft Covered Slab Floor, 4.00" thick at Master Suite The HVAC System "ZONE 2 (Guest Suite 1 U)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areai . HIGH MASS Design(see C -2R) -Verify Thermal Mass: 165 sqft Tile in Mortar Interior Mass, 0.75" thick at Guest Suite 1&2 H I G H MASS Design (see C -2R) -Verify Thermal Mass: 165sqft Exposed Slab Floor, 4.00" thick at Guest Suite 1&2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 940 sqft Covered Slab Floor, 4.00" thick at Guest Suite 1&2 The HVAC System "ZONE 3 (Living Area)" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 3084 sqft Tile in Mortar Interior Mass, 0.75" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 3084 sqft Exposed Slab Floor, 4.00" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 677 sqft Covered Slab Floor, 4.00" thick at Living Area HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the s ion of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing=e measures on a form CF -6R. I Plan I Field The HVAC System "ZONE 1 (Master Suite)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "ZONE 2 (Guest Suite 1 U)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "ZONE 3 (Living Area)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "ZONE 4 (Guest Suite #3)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. I Run Initiation Time: 11/03/03 08:21:01 Run Code: 1067876461 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page: 18 of 41 Computer Method Summary (Addendum) C -2R Lot #245 "The Hideaway" 11/3/2003 OprojectTitle Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 3aseo on ine aoequacy OT ine speciai JUSTITIcation ana aocumentation suomittea. The HVAC System "ZONE 4 (Guest Suite #3)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -21R) - Verify Thermal Mass: 81 sqft Tile in Mortar Interior Mass, 0.75" thick at Guest Suite #3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 81 sqft Exposed Slab Floor, 4.00" thick at Guest Suite #3 Plan I Field I HIGH MASS Design(see C -2R) - Verify Thermal Mass: 384 sqft Covered Slab Floor, 4.00" thick at Guest Suite #3 1 1 1 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the s ion of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing=e measures on a form CF -6R. F—P—la—n—F—Fi—eld I Run Initiation Time: 11/03/03 08:21:01 Run Code: 1067876461 EnergyPro 3.1 By EnergySoft User Number: 3665 — Job Number: 0032.00 Page: 19 of 41 DROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME Lot #245 "The Hid DATE 11/3/2003 ICOMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM I 2 Stucco Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 ASSEMBLY NAME IR -21 Wall (W.21.24.16) 0.31 8 0.37 9 2.60 ASSEMBLY Floor 0.680 0.680 1 23.111 TYPE (check one) Wall w Ceiling Roof a FRAMING MATERIAL 0 z FRAMING % % Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) El 1:1 E] 1:1 1:1 SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM I 2 Stucco Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.562 7 0.31 8 0.37 9 2.60 0.26 INSIDE SURFACE AIR FILM El 1:1 E] 1:1 1:1 SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.175 0.175 0.060 0.060 0.465 0.465 21.000 5.445 0.562 0.562 0.31 2.63 0.37 0.98 2.60 0.26 0.68 0.680 0.680 1 23.111 MG MT U�W *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-lb) HC (A X B) (Btu/F-sf) x 1 0.85 1 8.46 0.20 1.69 0.06 0.35 0.02 1.06 0.29 0.31 2.63 0.37 0.98 2.60 0.26 0.68 14.81 TOTAL HC NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. x 1 0.85 1 + 0.13231 x L 0.15 1] I / Rc 1 - (FrO/. / 100) 1 / Rf FrO/o/100 --j ASSEMBLY U-VALIJE EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Paqe: 20 of 41 1 E DROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME Lot #245 "The Hid DATE 11/3/2003 1COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 2 Gypsum or Plaster Board Insulation, Mineral Fiber, R-21 3 Gypsum or Plaster Board 4 0.562 5 0.37 6 ASSEMBLY NAME JR -21 Wall (W.21.24.16) (W-2) 0.68 8 ASSEMBLY U -VALUE 9 ASSEMBLY Floor 0.6801 0.680 1 22.981 TYPE (check one) Wall Ceiling Roof 0 FRAMING MATERIAL 0 z FRAMING % % Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) THICK- NESS kMING (in.) El 0.625 N 5.500 El 0.625 0 - El El El SUBTOTAI. R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 2 Gypsum or Plaster Board Insulation, Mineral Fiber, R-21 3 Gypsum or Plaster Board 4 0.562 5 0.37 6 2.60 7 0.68 8 ASSEMBLY U -VALUE 9 INSIDE SURFACE AIR FILM THICK- NESS kMING (in.) El 0.625 N 5.500 El 0.625 0 - El El El SUBTOTAI. R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.5621 0.562 21.000 5.445 0.562 0.562 0.37 0.98 2.60 0.26 0.68 FrO/6 / 100 ASSEMBLY U -VALUE 0.6801 0.680 1 22.981 Kc Kr *H E -AT CAPACITY (Optional) WALL WEIGAT (lbs/-cf) SPECIFIC HEAT (Btu/F-lb) HC (A X B) (Btu/F-sf) x 0.85 2.60 0.26 0.68 2.63 0.37 0.98 2.60 0.26 0.68 FrO/6 / 100 ASSEMBLY U -VALUE 7.81 TOTAL HC NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the f*arning members. x 0.85 + F-, 0.1348 x 0.15 1 / Rc I - (Fr -/6 / 100) 1 / Rf FrO/6 / 100 ASSEMBLY U -VALUE I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page:21 of 41 1 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY NAME Lot #245 "The Hid IF, SYSTEM NAME ZONE 1 (Master Suite) 24.0 OF 69.4 OF Outside Air 0 Cfm 69.4 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 11/3/2003 FLOOR AREA 1,335 COIL COOLING PEA COIL HTG. PEAK CFM I Sensiblel Latent , CFM I Sensible 1 30,1�00� HS26-060/G40UH60C-1 10 (5) 48,196 1,745 Total Adjusted System Oy.tput (Adjusted for Peak Design Conditions) 48,1961 17745 TIME OF SYSTEM PEAK I Aug 2 prn 105.0 OF Heating Coil Supply Fan 2000 cfm 1 267791 89,400 E� FJan 12 arni 105.0 OF 30� Supply Air Ducts 104.4 OF ROOMS 70.0 OF -h ReturnAirDucts COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 114.1 / 80.3 OF 78.6 / 63.2 OF 55.0 / 53.6 OF 55.0 / 53.6 OF .1 ow 4S SipplyAirDuctss Outside Air 0 Cfm Cooling Coil Supply Fan 55.6 / 53.8 OF 2000 cfm Q.3% R.H. ROOM 78.6/63.2 0 F 78.0 63.0 OF Return Air Ducts:31E EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page: 22 of 41 27,363 5,61 24,356 0 1,368 1,218 0 0 0 0 0 0 0 0 1,368 1,218 1 30,1�00� HS26-060/G40UH60C-1 10 (5) 48,196 1,745 Total Adjusted System Oy.tput (Adjusted for Peak Design Conditions) 48,1961 17745 TIME OF SYSTEM PEAK I Aug 2 prn 105.0 OF Heating Coil Supply Fan 2000 cfm 1 267791 89,400 E� FJan 12 arni 105.0 OF 30� Supply Air Ducts 104.4 OF ROOMS 70.0 OF -h ReturnAirDucts COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 114.1 / 80.3 OF 78.6 / 63.2 OF 55.0 / 53.6 OF 55.0 / 53.6 OF .1 ow 4S SipplyAirDuctss Outside Air 0 Cfm Cooling Coil Supply Fan 55.6 / 53.8 OF 2000 cfm Q.3% R.H. ROOM 78.6/63.2 0 F 78.0 63.0 OF Return Air Ducts:31E EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page: 22 of 41 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Lot #245 "The Hideaway" 11/3/2003 SYSTEM NAME FLOOR AREA ZONE 2 (Guest Suite 1&2) 1,105 lNumber of Systems OIL HTG. PEAK Heating System Output per System 72,100 Total Output (13tuh) 72,100 1 Output (Btuh/sqft) 65.21 Cooling System Output per System 48,000 Total Output (Btuh) 48,000 Total Output (Tons) 4.0 Total Output (Btuh/sqft) 43.4 Total Output (sqft[Ton) 276.2 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sqft) 1.45 Airflow (cfmfTon) 400.0 Outside Air (%) 0.0 Outside Air (cfmlsqft) 0.00 Note: values above given at ARI conditions 24.0 OF Outside Air 0 cfm 69.3 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK OIL HTG. PEAK 4,64411 iblel Latent � CFM I Sensible 1 26,19� 4,6441 HS26-048/G40UH48B-09OX (4) 39,604 1,406 Total Adjusted System Output (Adjusted for Peak Design Conditions) I 39,60:4E:I�j TIME OF SYSTEM PEAK I Aug 2 pm RICS (Airstream Tel 69.3 OF m 105.0 OF I Heating Coil res at Time of Heatina Pea 72,100 E� Jan 1 105.0 OF —IF S Supply Air Supply Fan 104.3 OF 1600 cfm ROOMS] 70.0 OF Return Air Ducts I res at Time of Coolin 114.1 / 80.3 OF 78.7 / 63.2 OF 55.0 / 53.6 OF 55.0 / 53.6 OF Supply Air Ducts 7� Outside Air I a 0 cfm Cooling Coil Supply Fan 55.7 / 53.8 OF 1600 cfm 43.4% R.H. ROOMS 1 78.7/63.2 0 F 78.0 63.0 OF (6 E ;e ��—Return Air Ducts:sle L EnergyPro, 3.1 By EnergySoft User Number: 3665 Job Number. 0032.00 Page:23 of 41 23,810 4,64411 62 23,463 0 1,190 1,173 0 0 0 0 0 0 1,190 1,1731 1 26,19� 4,6441 HS26-048/G40UH48B-09OX (4) 39,604 1,406 Total Adjusted System Output (Adjusted for Peak Design Conditions) I 39,60:4E:I�j TIME OF SYSTEM PEAK I Aug 2 pm RICS (Airstream Tel 69.3 OF m 105.0 OF I Heating Coil res at Time of Heatina Pea 72,100 E� Jan 1 105.0 OF —IF S Supply Air Supply Fan 104.3 OF 1600 cfm ROOMS] 70.0 OF Return Air Ducts I res at Time of Coolin 114.1 / 80.3 OF 78.7 / 63.2 OF 55.0 / 53.6 OF 55.0 / 53.6 OF Supply Air Ducts 7� Outside Air I a 0 cfm Cooling Coil Supply Fan 55.7 / 53.8 OF 1600 cfm 43.4% R.H. ROOMS 1 78.7/63.2 0 F 78.0 63.0 OF (6 E ;e ��—Return Air Ducts:sle L EnergyPro, 3.1 By EnergySoft User Number: 3665 Job Number. 0032.00 Page:23 of 41 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Lot #245 "The Hideaway" 11/3/2003 is SYSTEM NAME FLOOR AREA ZONE 3 (Living Area) 3,761 24.0 OF 69.4 OF Outside Air 0 CfM 69.4 OF 114.1/80.30F Outside Air 0 CfM 78.6/63.1 0 F M Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 1 83,8361 15,8071 F----78,4610 HS26-060/G40UH60C-1 10 (5) 144,766 4,887 268,200 Total Adjusted System Output (Adjusted for Peak Design Conditions) 1 144,7661 4.8871 E:iiii TIME OF SYSTEM PEAK Aig 2 prn] Jan 12 arni Heating Coil _Q@J Supply Fan 6000 cfm 78.6 / 63.1 OF 55.0 / 53.6 OF %� 0 Cooling Coil 105.0 OF Supply Air Ducts 104.4 OF ROOMS 70.0 OF A;� M-4- Supply Fan 6000 dm 55.0 / 53.6 OF Supply Air 55.6/53 . 8 OF 43.1% R.H. ROOM 78.0 / 62.9 OF LD-#,.,- A;, r*t,.-#, U EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page: 24 of 471�] 76,214 71,327 0 3,811 3,566 0 0 0 0 0 0 0 0 1 3,8111 1 3,566 1 83,8361 15,8071 F----78,4610 HS26-060/G40UH60C-1 10 (5) 144,766 4,887 268,200 Total Adjusted System Output (Adjusted for Peak Design Conditions) 1 144,7661 4.8871 E:iiii TIME OF SYSTEM PEAK Aig 2 prn] Jan 12 arni Heating Coil _Q@J Supply Fan 6000 cfm 78.6 / 63.1 OF 55.0 / 53.6 OF %� 0 Cooling Coil 105.0 OF Supply Air Ducts 104.4 OF ROOMS 70.0 OF A;� M-4- Supply Fan 6000 dm 55.0 / 53.6 OF Supply Air 55.6/53 . 8 OF 43.1% R.H. ROOM 78.0 / 62.9 OF LD-#,.,- A;, r*t,.-#, U EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page: 24 of 471�] HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Lot #245 "The Hideaway" 11/3/2003 is SYSTEM NAME FLOOR AREA ZONE 4 (Guest Suite #3) 465 ENGINEERING CHECKS [Number of Systems CFM Heating System Output per System 36,000 Total Output (Btuh) 36,000 Output (Btuh/sqft) 77.4 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) Total Output (Btuh/sqft) 51.6 Total Output (sqft/Ton) 232.5 0 0 YSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COILHTG.PEAK CFM ISen iblel Latent �� CFM I Sensible 1 11,4:23[=�;� Air bystern I HVAC: EQUIPMENT SELECTION CFM per System 800 , 36,000 HS26-024/G40UH24A-045X (2) 19,888 557 Airflow (cfm) 800 Airflow (cfm/sqft) 1.72 Airflow (cfmrron) 400.01 Total Adjusted System Output 19,8881 J7 Outside Air 0.0 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I __55 Aug 2 prn Outside Air (cfm/sqft) 0.00 Jan 12 arril Note: values above given at ARI cond��� HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 24.0 OF 69.2 OF 105. 0 OF 105.0 OF %� .e %� .1 — 11 Outside Air �=Wl 4� SupplyAii-Ductss 0 Cfm 104.2 OF Heating Coil Supply Fan 800 Cfm ROOMS 70.0 OF 69.2 OF <— Return Air Ducts COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak). 114.1 / 80.3 OF 78.6/63.110F 55.0 / 53.5 OF 55.0 / 53.5 OF 311. Outside Air 1 0 4 S..jpply Air Ducts 0 Cfm Cooling Coil Supply Fan 55.6 / 53.8 OF 800 cfm FROOMS 42.9% R.H. 78.6/63.1 0 F 78.0 62.9 OF v9d Return Air Ducts EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page: 25 of =41 0 41 1� IROOM LOAD SUMMARY PROJECT NAME Lot #245 "The Hideaway" DATE 11/3/2003 SYSTEM NAME ZONE 1 (Master Suite) FLOOR AREA 1,335 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONENAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE1 Master Suite 1 1,102 27,363 5,611 1,102 27,363 5,611 645 24,356 PAGE TOTAL TOTAL 1 1,1021 27,36:; 1 5,6-1111 6451 2 1 1,1021 27,3631 5,61111 6451 2 I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page:26 of 41 41 41 IROOM LOAD SUMMARY PROJECT NAME Lot #245 "The Hideaway" DATE 11/3/2003 SYSTEM NAME ZONE 2 (Guest Suite 1 &2) FLOOR AREA 1,105 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE 2 Guest Suite 1&2 1 959 23,810 4,644 959 23,810 4,644 621 23,463 PAGE TOTAL 1 9591 23,8101 4, 1 6211 23,463] TOTAL 1 9591 23,8101 4,64411 6211 23,463] I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page:27 of 41 0 All w 41 IROOM LOAD SUMMARY PROJECT NAME DATE Lot #245 "The Hideaway" 11/3/2003 TYSTEM NAME FLOOR AREA ZONE 3 (Living Area) 3,761 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONENAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE3 Living Area 1 3,069 76,214 15,807 3,069 76,214 15,807 1,888 71,327 PAGE TOTAL 1 3,0691 76,2141 15,80711 1,8881 7 TOTAL 1 3,0691 76,2141 15,80711 1,8881 7 I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page: 28 of 41 ] IROOM LOAD SUMMARY PROJECT NAME DATE Lot #245 "The Hideaway" 11/3/2003 SYSTEM NAME FLOOR AREA ZONE 4 (Guest Suite #3) 465 IROOM LOAD SUMMARY 1 4181 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONENAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE4 Guest Suite #3 1 418 10,385 1,954 418 10,385 1,954 352 13,317 PAGE TOTAL TOTAL 1 4181 10,38E 1 1,9 1 3521 1 1 4181 10,38! 1 1,95411 3521 1 I EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. 0032.00 Page:29 of 41 1 I ROOM HEATING PEAK LOADS Project Title Date Lot #245 "The Hideaway" �1 1/3/2003 Ll hoom Information Desicin Conditions Room Name Master Suite Time of Peak Jan 12 am Floor Area 1,335 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF 0 Conduction Area U -Value 6,T OF Btulhr 1,335.0 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 1,720 619.3 0.0566 46.0 1,613 101.4 0.4600 46.0 2,146 75.0 0.0572 46.0 197 135.0 0.4800 46.0 2,981 21.3 0.5000 46.0 490 perimeter 89.0 45.5 4,050 items snown wim an astenSK aenote, conauction tnrougn an interior surtace to anotner room. Infiltration: 1.00 1 x ir Sensible x Area x Ceiling Height x ACH Fraction 60] x Page Total: ln:T 13,196 TOTAL HOURLY HEAT LOSS FOR ROOM I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page: 30 of 41 1 I ROOM HEATING PEAK LOADS 0 Project Title Dat Lot #245 "The Hideaway" �1 1/3/2003 Room Information Desi-qn Conditions Room Name Guest Suite 1 &2 Time of Peak Jan 12 am Floor Area 1,105 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 7 Conduction Area U -Value .!nT OF Btu/hr 1,105.0 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 1,423 770.7 0.0566 46.0 2,007 35.0 0.5000 46.0 805 95.3 0.4600 46.0 2,017 167.0 0.0572 46.0 440 96.0 0.4800 46.0 2,120 perimeter 119.0 45.5 5,414 nems snown witn an astenSK (-) aenote conauction through an interior surface to another room. Page Total: 14,226 Infiltration: I 1.001-x x x x 60] x chedule Air Sensible Area Coiling Height ACH ins Fraction TOTAL HOURLY HEAT LOSS FOR ROOM I EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: 0032.00 Page: 31 of 41 I ROOM HEATING PEAK LOADS 0 Project Title Date Lot #245 "The Hideaway" 111/3/2003 Room Information Desiqn Conditions Room Name Living Area Time of Peak Jan 12 am Floor Area 3,761 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value &T OF Btu/hr 3,761.0 1,957.7 166.3 386.0 521.0 36.0 24.0 144.0 perimeter = 260.0 0.0280 0.05661 0.4600 0.4800 0.0572 0.5000 0.3872 0.5200 Items shown with an asterisk (*) denote conduction through an interior surface to another room. Infiltration: I 1.001X x x x 60] x charb-le Air Sensible Area Ceiling Height ACH Fraction 4M5 5,099 3,519 8,523 1.371 828 427 3,444 11,830 --"age Total: 39,887 e -T TAL HOURLY HEAT LOSS FOR ROOM 71 I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. 0032.00 Page: 32 of 41 1 I ROOM HEATING PEAK LOADS �j Project Title Date Lot #245 "The Hideaway" 111/3/2003 --1 Room Information Desicin Conditions Room Name Guest Suite #3 Time of Peak Jan 12 am Floor Area 465 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr 1 465.0 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 599 660.6 0.0566 46.0 1,721 47.4 0.4600 46.0 1,003 10.0 0.5000 46.0 230 48.0 0.4800 46.0 1.060 257.0 0.0572 46.0 676 pefteter 91.0 45.5 4,140 items snown wim an astenSK (-) cenote conauction through an interior surtace to another room. Infiltration: 1 1.001 x x x ir Sensible Area Coiling Heigh Fraction TOTAL HOURLY HEAT Page Total: 1 9,429 t x ACH 60] x W I I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. 0032.00 Page:33of4l --�:] E RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #245 "The Hideaway" 111312003 Project Tifle Date Room Name Master Suite Design Indoor Dry Bulb Temperature: 780F Design Outdoor Dry Bulb Temperature: 115 0 F Design Temperature Difference: 37 10 F Conduction R-38 Roof (R.38.2xl4.16) R-21 Wall (W.21.24.16) Sierra Pacific Clad (Lo/E) R-21 Wall (W.21.24.16) (W-2) Sierra Pacific Clad (Lo/E) Sierra Pacific Clad (Lo/E) Area U -Value x :)ETD' x 56.0 x 35.6 x 37.0 x 35.6 x 37.0 x x x x 1. Design Equivalent Temperature Difference (DETD) Fage Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. Shaded Unshaded Btu/hr 2,094 1,248 1,726 153 2,398 Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxdGIsWdw Q5 Abv.) (North) FxcLGIs.VVdw (06 Aby) (East) FxdGIsWdw iw Abv.-) (Southeast) FrnchDr (34) (Southeast) FxdG]sWdw (12) FxdGIsWdw (11) (Southeast) (Southeast) FxdG[sWdw (W) (Southeast) FxdG]sWdw (G6) (Southeast) FxdGIsWdw (G5) (Southeast) FxdGIsWdw (Q2 Abv.) (South) 0.0 x x x x x x x x x x 15 + + + + + + + + + + 1.0 x X x x X x x X x x 15 �X >x )X )_x N x :x 0.42 = = = = = = = = 6. 0.0 15 1.0 73 0.423 31 0.0 15 1.0 62 0.42 26 0.0 15 48.0 62 0.423 1,259 0.0 15 6.3 62)x 0.423 165 0.0 1 6.3 62)X 0.423 165 0.0 1 6.3 62)X 0.423 165 0.0 1 6.3 62 0.423 165 0.0 1 6.3 62: 0.423 EM 165 0.0 1 1.01 14 a h A Page Total %. a . Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 1,335 0.500 Wafts/sqft x 3.412 BtuhfWaft 2,278 Occupants 1.00 X 1,335 X 255 Btuh/occ. 333 scft/occ. 1,022 Receptacle 1.00 x 1,335 x 0.000 Wafts/sqft x 3.413 131�uh/Watt 0 Process 1.00 x 1,335 x 0.000 Wafts/sqft x 3.412 BI1uhfWatt 0 Infiltration: x x x x 60] Air Sensible Area Ceiling Height ACH Fraction FOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 27,3631 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 1,335 X 225 Btuh/occ. sqft/occ. Receptacle 1.00 x 1 335 x 0.000 Wafts/sqft x 1131.uhMatt = 1.00 X A Process - 1335 X 0.000 Wafts/sqft x 113-uhMatt = Infiltration: chedule x Air Latent x Area x Ceiling Height x ACH 60] _-W Fraction [TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 5,6111 I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page: 34 of 41 40 0 9 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #245 "The Hideaway" 111312003 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Master Suite 780F 115 0 F 37 10 F Conduction Area U -Value :)ETD' Btu/hr x x x x x x x x x 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxdGIsWdw (G4) (Southwest) -rnrhr)r (96) (Southwest) FAGM�dv� (G3) (Southwest) FxdGIsWdw (Q3 Abv.) (West) CsmntWdw (G2) (West) FrnchDr (27) (West) FxdGisWdw (Gl) (West) FxdGIsWdw (Q4 ABV.) (Northwest) 1,652 0.0 I 1, 21.3 0.0 x x x x x x x x x x 1 + + + + + + + + + + 21. x x x x X x x x x x 62)X >X )X 0.42 = = = = = = = = 559 0.0 1 63.0 62)x 0.423 1,652 0.0 I 1, 21.3 62)x 0.423 559 0.0 1 1.0 73)x 0.423 31 (-0.0 21.3 73)x 0.445 692 0.0 1! 24.0 73)0( 0.423 741 0.0 1! 21.3 73),X 0.423 658 0.0 1! 1.0 48 0.423 20 F- ---1 Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Liqhts 1.00 1,335 X . 0.500 Wafts/sqft x 3.41 Btuh[Waft 2,278 Occupants 1.00 X 1,335 X 255 Btuh/occ. / 33 sqft/occ. 1,022 Receptacle 1.00 x 1,335 x 0.000 Wafts/sqft x 3.413 BtjhfWaft 0 Process 1.00 x 1,335 x 0.000 Wafts/sqft x 3.412 Bt i hMatt 0 Infiltration: x Air Sensible x Area x Ceiling Height x ACH 60] Zsr Fraction FOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 27,36J Sched. Latent Gain Frac. Area Heat Gain Btuffir Occupants 1.00 X x 225 Btuh/occ. sqft/occ. Receptacle 1.00 X x 0.000 Wafts/sqft x BtuhfVVaft = Process 1.00 x x 0.000 Wafts/sqft x BtiuhfWaft = Infiltration: chedule x Air Latent x Area x Ceiling Height x ACH 60] LIN Fraction FTOTAL HOURLY LATENT HEAT GAIN FOR ROOM 5,611 JEnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: 0032.00 Page: 35 of 41 0 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #245 "The Hideaway" 11/3/2003 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-38 Roof (R.382A4.16) R-21 Wall (W.21.2x6.16) Sierra Pacific Clad (Lo/E) Sierra Pacific Clad (Lo/E) R-21 Wall (W.21.2x6.16) M-2) Sierra Pacific Clad (Lo/E) Area U -Value x Guest Suite 1 &2 780F 115 0 F 37 10 F DETD' x 56.0 x 35.6 x 37.0 x 37.0 x 35.6 x 37.0 x x x 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. Shaded Unshaded Btu/hr 1,733 1,554 648 1,622 340 1,705 Solar Gain Orientation Area SGIF Area SGIF SC Btu/hr CsmntWdw (1-2) (Northeast) .C.s W(1vv (1 11 - (Northeast) _ FxdGIsWdw'(Ki) (Northeast) FxdGIsWdw (K2) (Southeast) FxdGIsWdw (Kl) (Southeast) FxdGisWdw (A) (Southeast) FrnchDr (37) (Southeast) SwngGisDr (43) (West) FxdGisWdw (1-4) (West) FxdGIsWdw (1-3) 1 (North st) 0.0 x x x x x x x x x x 1 + + + + + + + + + + 17.5 x X x x x x x X X X 48)X )x 0.445 = = = = = = = = = 374 0.0 1 17.5 48)x 0.445 374 0.0 1 1, 5.0 48)x 0.423 102 0.0 1 2.3 62)x 0.423 60 0.0 45.0 62)x 0.423 1,180 0.0 1 15.0 62)X 0.423 393 0.0 1 48.0 62)X 0.423 1,259 0.0 I Al 48.0 73)X 0.423 1,482 0.0 1 24.0 73)x 0.423- 741 0.0 4.0 0.4231 Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Licihts 1.00 1,105 0.500 Wafts/sqft x 3.413 Btuh/Waft 1,886 Occupants 1.00 X 1,105 X 255 Btuh/occ. / 333 sqft/occ. 846 Receptacle 1.00 x 1,105 x 0.000 Wafts/sqft x 3.413 BtuhfWaft 0 Process 1.00 x 1,105 x 0.000 Wafts/sqft x 3.412 BtuhMatt 0 Infiltration: x x x E:]�ia x 60] Air Sensible Area Ceiling Height ACH z-\ T Fraction ITOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 23,8101 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants -1-00 x x 225 Btuh/occ. sqft/occ. Receptacle 1.00 x x 0.000 Wafts/sqft x BtuhNVaft = Process 1.00 x [A x 0.000 Wafts/sqft x BtuhfWaft = Infiltration: 1.. 01 x tent x Area x Ceiling Height x ACH 60] "-\W Fraction [TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,644] JEnergyPro 3.1 By EnergySoft User Number 3665 Job Number: 0032.00 Page: 36 of 41 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #245 "The Hideaway" 111312003 Project Title Date Room Name Living Area Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-38 Roof (R.38.2xl4.16) R-21 Wall (W.21.2x6.16) Sierra Pacific Clad (Lo/E) Sierra Pacific Clad (Lo/E) R-21 Wall (W.21.2x6.16) (YV-2) Sierra Pacific Clad (Lo/E) Solid Wood Door Sierra Pacific Clad (Lo/E) Area U -Value 761 x DETD 1 56.0 35.6 37.0 37.0 35.6 37.0 35.6 37.0 1. Design Equivalent Temperature Difference (DETD) P 3ge Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. Shaded Unshaded 780F 115 0 F 37 10 F Btu/hr 5,898 3,946 2,830 6,855 1,061 666 331 2,771 Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxdGIsWdw (R3 Abv.) (North) FxdGIsWdw (122 Aby) (North) FxdG[sWdw (Nl) (North) FrnchDr (48) (North) FxdGIsWdw (N2) (North) CsmntWdw (E) (Northeast) FxdGIsWdw (P1 Abv.) (Northeast) SvvngG1sDr-(1 Entry) (Northeast) FxdGisWdw (1A) (Northeast) FxdGIsWdw (1 B) (Northeast) 0.0 x x x x x x x x x XA1 1 + + + + + + + + + + 1.2 x X x x X X x X X x 1 )X ) X K )K 0.42 = = 8 0.0 I 1.0 1 0.423 6 0.0 1 1, 24.0 15)--( 0.42 152 0.0 1 24.0 15)-t 0.42 152 0.0 24.0 15)-c 0.423 152 0.0 1� 13.5 48)--( 0.445 289 0.0 1 1.0 48)-.( 0.423 20 0.0 1 38.0 48)--( 0.423 772 0.0 1 21.0 48) 0.423 426 0-0 21.0 0.423 426 Sched. Rage Total Internal Gain Frac. Area Heat Gain Btu/hr Liq hts 1.00 3,761 0.500 Wafts/sqft x 3.413 Btuh/Watt 6,418 Occupants 1.00 X 3.76 X 255 Btuh/occ. / 333 sq1t/occ. 2,880 Receptacle 1.00 x 3,76 x 0.000 Wafts/sqft x 3.413 BtuhNVatt 0 Process 1.00 x 3,761 x 0.000 Watts/sqft x 3.413 BtuhNVaft 0 Infiltration: x x x x / 60] E!�-3 Air Sensible Area Ceiling Height ACH Z-\ I Fraction FOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 76,2141 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x x 225 Btuh/occ. sqft/occ. Receptacle 1.00 x x 0.000 Watts/sqft x BtuhMatt = Process I A10 0 x x 0.000 Watts/sqft x l3twhMatt = Infiltration: I 1.00l x L 4,8401 X x x 60] itent Area Ceiling Height ACH Z!,W Fraction [TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 15,807 lEnergyPro 3.1 By EnergySoft User Number 3665 Job Number: 0032.00 Page: 37 of 41 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #245 "The Hideaway" 11/3/2003 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value x DETD' 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. Shaded Unshaded Living Area 780F 115 0 F 37 10 F MM7 Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxdGisWdw (P8 Aby.) (East) Exd-G1 dw (Al) (East) FrnchDr (5) (East) FxdGIsWdw (A2) (East) FxdGisWdw (P7 Abv.) (Southeast) FrnchDr (9) (Southeast) FxdGisWdw (KAbv.) (South) FrnchDr (2) FxdGIsWdw (P5 Abv.) (South) (Southwest) iFrnchDr (3) (Southwest) 0.0 x x x x x x x x X x 1 + + + + + + + + + + 1.0 x X x x X x x X X x 73)X )X 0.42 = = = = = = = = 31 0.0 1 24.0 73)x 0.42 741 0.0 1 24.0 73)r 0.423 741 0.0 1 24.0 73)x 0.423 741 0.0 1 11 1.0 62)x 0.423 26 0.0 1 57.0 62)X 0.423 1,495 0.0 1 1.0 32)X 0.423 14 0.0 1 73.0 32)X 0.423 988 0.0 1 1.0 6 0.423 26 0-0 73.0 62)x 0.423 1,915 Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 3,761 0.500 Wafts/sqft x 3.41 13tuih/Waft 6,418 Occupants 1.00 X 3.76 X 255 Btuh/occ. / 333 sqfJocc. 2,880 Receptacle 1.00 x 3,76 x 0.000 Wafts/sqft x 3.413 Btuh[Waft 0 Process 1.00 x 3,761 x 0.000 Wafts/sqft x 3.412 BtuhMaft 0 Infiltration: x x x x E:Io� 6o] E= 1 252891 Air Sensible Area Ceiling Height ACH Z-\ T Fraction [TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 76,2141 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x x 225 Btuh/occ. sqfJocc. Receptacle 1.00 X x 0.000 Wafts/sqft x Btulh[Watt = Process 1.00 x x 0.00 1 Wafts/sqft x BtuhfWaft = Infiltration: a, 1.001 x nt x Area x Ceiling Height x ACH 60] In1w Fraction ITOTAL HOURLY LATENT HEAT GAIN FOR ROOM 15,807 lEnergyPro 3.1 By EnergySoft User Number: 3665 - Job Number: 0032.00 Page: 38 of 41 1 0 E 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #245 "The Hideaway" 11/3/2003 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value x DETD 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. Shaded Unshaded Living Area 780F 115 0 F 37 10 F Btu/hr Solar Gain Orientation Area SGIF Area SGF SIC Btu/hr SldqGlsDr (24) (Southwest) ,FxdGIsWdw (P4 Aby) (West) FrnchDr (4) (West) FxdGIsWdw (R1 Abv.) (West) FxdGIsWdw (P3 Abv.) FxdGisWdw (F4) (Northwest) (Northwest) FxdGIsWdw (F3) (Northwest) FxdGIsWdw (F2) (Northwest) CsmntWdw (Fl) (Northwest) IFrnchDr (21) (Northwest) 0.0 x x x x x x x x x x 1 + + + + + + + + + 144.0 x X x x X x x X X x 6 )X )x )xl 0.501 = = = = = = = = 4,472 0.0 1 1.0 7 0.423 31 0.0 1 1, 73.0 73)X 0.423 2,254 0.0 1 1.2 73)x 0.42 39 0.0 1.0 48)x 0.423 20 0.0 1�+ 4.0 48)X 0.423 81 0.0 1 4.0 48)X 0.423 81 0.0 1 4.0 48)X 0.423 81 0.0 1 1, - 22.5 48)x 0.445 481 0-0 24.01 0.423 487 Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Liqhts 1.00 x 3761 0.500 Wafts/sqft x 3.41 Btuh/Watt 6,418 Occupants 1.00 X 3,76 X 255 Btuh/occ. / 333 sqft/occ. 2,880 Receptacle 1.00 x 3,76 x 0.000 Wafts/sqft x 3.413 BtuhNVaft 0 Process 1.00 x 3,761 x 0.000 Wafts/sqft x 3.413 BtuhNVatt 0 Infiltration: x Air Sensible x Area x Ceiling Height x ACH 60] z2sT Fraction [TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 76.21741 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X x 225 Btuh/occ. sqft/occ. Receptacle 1.00 x x 0.000 Wafts/sqft x BtuhfWaft = Process 1.00 x x 0.000 Wafts/sqft x BtuhfWaft = Infiltration: ool x E 4,8401 X x x 60] tent Area Ceiling Height ACH 1n1W Fraction ITOTAL HOURLY LATENT HEAT GAIN FOR ROOM 15,8071 lEnergyPro 3.1 By EnergySoft User Number 3665 Job Number: 0032.00 Page: 39 of 41 1 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #245 "The Hideaway" 111312003 Project Tifle Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value x DETD 1 Living Area 780F 115 0 F 370F Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxdGisWdw (N11) (Northwest) — 0.0 x 15 + 2.3 x 48 )X 0.423 = 47 EXCLG1s.WAw-(M 2) (Northwest) — 0.0 x 15 + 2.3 X 4 )x 0.423 = 47 FxdGIsWdw (R2 AN.) (Northwest) 0.0 x 15 + 1.2 x 48)X 0.423 = 24 x + x x x + x x x + x x x + x —)x x + X )x x + x x x + x x Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Liqhts 1.00 x 3,761 0.500 Wafts/sqft x 3.413 Btuh/Waft 6,418 Occupants 1.00 X 3.76 X 255 Btuh/occ. / 333 sqft/occ. 2,880 Receptacle 1.00 x 3,76 X 0.000 Wafts/sqft x 3.413 Btuh/Watt 0 Process 1.00 x 3,761 x 0.000 Wafts/sqft x 3.413 BtuhMatt 0 Infiltration: x Air Sensible x Area x Ceiling Height x ACH 60] z-\ T Fraction [TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 76,2141 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X x 225 Btuh/occ. sqft/occ. Receptacle 1.00 x x 0.000 Wafts/sqft x BtuhMatt = Process 1.00 x x 0.000 Wafts/sqft x BtuhfWaft = Infiltration: I tool x L 4,8401 X x x 60] 3tent Area Ceiling Height ACH Z -\W Fraction ITOTAL HOURLY LATENT HEAT GAIN FOR ROOM 15,8071 1EnergyPro 3.1 By EnergySoft User Number 3665 Job Number. 0032.00 Page: 40 of 41 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #245 "The Hideaway" 111312003 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Guest Suite #3 780F 115 0 F 370F Conduction Area U -Value DETD' Btu/hr x x x x x x 56.0 = = = = = = 729 35.6 1,332 37.0 807 37.0 185 37.0 852 35.6 523 x x x 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGIF Area SGF SIC Btu/hr FxdGisWdw (Q3) (North) .Cr.m (C-2) (Northeast) FxdGisWdw (K) (Northeast) FxdGisWdw (Cl) (East) FxdG]sWdw (E12) (Southeast) FrnchDr (11) (South) FxdGisWdw (Bl) (South) 4 0.445 214 0.0 1 11 15.0 0.0 x x x x x x x x X x 1 + + + + + + + + + + 2.2 x X x x X x x x x x 15)X )x )X -C 0.423 = = = = = = = 14 0.0 1 10.0 4 0.445 214 0.0 1 11 15.0 48)X 0.423 305 0.0 1 2.2 73)x 0.423 68 0.0 4.0 62)x 0.423 105 0.0 15 48.0 32)X 0.423 650 0.0 15 24.0 32)x 0.423 325 -)x F---]) Sched. P3ge Total Internal Gain Frac. Area Heat Gain Btulhr Lights 1.00 465 0.500 Wafts/sqft x 3.41 BtL hNVatt 794 Occupants 1.00 X 465 X 255 131uh/occ. / 333 sqtt/occ. 356 Receptacle 1.00 x 465 x 0.000 Wafts/sqft x 3.413 BtL h/Watt 0 Process 1.00 x 465 x 0.000 Wafts/sqft x 3.413 BtLhMaft 0 Infiltration: x x x x 60] E!�- = Air Sensible Area Ceiling Height ACH Z-\ T Fraction FOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,3851 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 465 X 225 Btuh/occ. sq2t/occ. Receptacle 1.00 X x 0.000 Wafts/sqft x Btuh/Watt = Process 1.00 x x 0.000 Wafts/sqft x Btuh/Watt = Infiltration: chedule x Air Latent x Area x Ceiling Height x ACH 60] Invq Fraction ITOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,9541 By EnergySoft User Number: 3665 - Job Number: 0032.00 Page: 41 of 41 1