04-4825 (SFD)T,Vf 4 4 a" P.O. Box 150.4 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING PERMIT Application Number . . . Property Address . . . . APN: Application description Property Zoning . . . . . Application valuation . . Owner --------------------------------- MICHAIL LONEGAN 50-855 WASHINGTON ST LA QUINTA, CA 92253 BUILDING & SAFETY DEPARTMENT (760),777-7012 FAX (760) 777-7011 INSPECTION REQUESTS (760) 777-7153 04-00 . 04825 Date 1/14/05 80280 VIA PESSARO 772 -550 -012 - DWELLING - SINGLE FA14ILY DETACHED LOW DENSITY RESIDENTIAL 330510 Contractor ALPHA OMEGA COMMUNICATIONS INC 42829 COOK STREET PALM DESERT, CA 92260 (760)568-1712 WCC: STATE FUND WC: 164166403 06/30/05 CSLB: 820066 05/31/05 CCC: B P.O. Box 1504 78-495 CALLE TAMPICO VOICE (760) 777-7012 FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 C&f Ot INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: 4, Z4 5 Date: Applicant Applicant's Mailing Address: Architect —110-chitect --bc. No.: or Engineer: or Engineer's Address: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals ,,,,.;,ode,and my Licen%Q in full force and effect. L n e Class I -t-,cense No._2 aQ0 & (,9 ,,-'Date eo-n I ma c�t o r� OW�ER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law forthe following reason (Sec. 7031.5. Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violabon of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U 1. as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. _, BA P.C. for this reason Date WORKERS'COMPENSATION DECLARATION I hereby affirnn under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 ofthe Labor Code, forthe performance of the work for which this permit is issued. I have and will maintain workers'compens tion insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is o�rk7' co =pe.!�'�,'Zurance carrier a - d er cl rjum rare: w .ou �o Policy Number VD I certify that, in 4he performance of the work for whicF this perinit is issued, I shall not emF10—y any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. WARNINt3: FAILURE To SECURE w6RKERS'COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION. DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST. AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of pedury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lenders Name im A Lenders Address 0 1A APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this applicabon. I . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application. the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta. its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize re I entatives of this county to enter upon the above-mentioned property for inspection purposes. 0 pplicant or Agent): ---------------------------------------------------------------------------- Application Number .. . . . . 04-00004825 ---------------------------------------------------------------------------- ------ Structure Information 3750 SQ. FT. SFD ----- Construction Type .- . . . . TYPE V- NON RATED Occupancy Type . . . . . . DWELLG/LODGING/CONG <=10 Flood Zone . . . . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC # BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG 915.00 PATIO SQ FTG 720.00 NUMBER OF UNITS 1.00 ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 3750.00 Permit . . . . . . BUILDING PERMIT Additional desc Permit Fee . . . . 1448.00 Plan Check Fee 941.20 Issue Date . . . . Valuation 330510 Expiration Date 6/14/05 Qty Unit Charge Per Extension BASE FEE 639.50 231.00 3..5000 ---------------------------------------------------------------------------- THOU BLDG 100,001-500,000 808.50 Permit . . . . . . MECHANICAL Additional desc . . Permit Fee . . . . 121.00 Plan Check Fee 30.25 Issue Date, Valuation . . . . 0 Expiration Date 7/14/05 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 9.0000 EA MECH FURNACE <=100K 27.00 3.00 9.0000 EA MECH B/C <=3HP/100K'BTU 27.00 7.00 6.5000 EA MECH VENT FAN 45.50 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc . . Permit Fee . . . . 179.55 Plan Check Fee 44.89 Issue Date . . . . Valuation . . . . 0 Expiration Date 7/14/05 Qty Unit Charge Per Extension BASE FEE 15.00 3750.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 131.25 915.00 ..0200 ELEC GARAGE OR NON-RES--DENTIAL 18.30 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . . . . PLUMBING Additional desc Permit Fee . . . . 189.'75 Plan Check Fee 47.44 Issue Date . . . . Valuation 0 Expiration Date 7/14/05 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Application Number . . . . . 04-00004825 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING Qty Unit Charge Per Extension 18.00 6.0000 EA PLB FIXTURE 108.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 13.00 .7500 EA PLB GAS PIPE >=5 9.75 1.00 15.0000 ----------------------------------------------------------------------------- EA PLB GAS METER 15.00 Permit . . . . . . GRADING PERMIT Additional desc Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/14/05 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 3750 SQ. FT. SFD THIS PERMIT DOES NOT INCLUDE POOL & SPA, BLOCK WALLS OR DRIVEWY APPROACH. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 326.27 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 94.12 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE 00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) RES 33.05 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION RES 1098.00 Fee summary Charged Paid Credited ----------------- Due ---------- Permit Fee Total ---------- ---------- ---------- 1953.30 .00 .00 1953.30 Plan Check Total 1063.78 .00 .00 1063.78 Other Fee Total 2858.44 .00 .00 2858.44 Grand Total 5875.52 .00 _00 5875.52 Building Address WO — C&tyl 0 4 a" . BOX 1504 A�IkTl eN 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Mailing % Address W#ht 4 St- 17,w ity () Z* 101, TI t? Zip * Tel. r1410L C State Lic. City Lic. &Classif. Lic. # Arcn., tngr., Designer ZiPP7 1 ,7 Stale Lic. # LICENSED CONTRACTOR'S DECLARATION I hereb affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of tivision 3 of the Business and Professions Code, and my license is in full force and effect. DATE OWNER -BUILDER DECLARATION I hereby affirm th I I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5.Lsiness and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to'lls issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code. or that.he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). (_11 I as owner of the property, or my employees with wages as their sole compensation, will do ihe work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If. however, the building or impro�ernent is sold within one year of completion. the owner -builder will have the burden of proving that he did no, build or improve for the purpose of sale.) (I I. as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) 1-1 1 am exempt under Sec. -B. & P.C. for this reason Date -Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company n Copy is filed with the city. 0 Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thp work. for which this permit is issued, I shall not empi oy any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date_Owner NOTICE TO APPLICANT: /I. after making this Certificate of Exemption you Should become subject to rhe Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I he 'eby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 309 7, Civil Code.) Lender's Name - Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration it work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information Is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of so Mailing Addres City, State, Zi BUILDING: TYPE'CONST. OCC. GRP. U A.P. Number -7 74 - 66;D - 012 -3 I q 7f -A &-r �Oqap q4- 7 Legal Description 1,4�LL Project Description U WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION , Sq. Ft. Size No. No. Dw. Stories Units New Add 0 Alter 0 Repair 0 Demolition 0 Ivo A(_� cHcck 0Le1o__s-,,-r- A-cceo7a, Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line —Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION , Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 3984224 Project Name: Tj]�� Owner's Name: Michael This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVELTVOAMOUNT: HITIGATION AMOUNT: COMM/IND. AMOUNT: DATF.- RF.r.F.IPT- r114F.r.K 0. INITIAIN' CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Address: 80-280 Via Pessaro La Quinta, CA Project Description: 1 SFD Date: January 24, 2005 PhoneNo. APN: 772-550-012 Tract #: Lot #'s: Type of Development: Residential IRIX-1 Commercial Industrial Total Square Feet of Building Area: 3,750 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of pe�ury and further represents that he/she is authorized to sign on behalf of the owner/deveaciper. C) Dated: January 24, 2005 Signature: I/VX SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE Of THE FOLLOWING: (CIRCLE ONE) Education Code Gov.Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/l/87 Requirement Note: Number of Sq.Ft. 3,750 Amount per Sq.Ft. $ 2,68 Amount Collected $ 10.050.00 Building Perndt Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: EiviraMattson, Office Technician Signature: K �, � , � �/, /�', � � NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition ofthese Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and othe!.- applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the paymeoit of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days start. on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the'project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. W'C()I-nPliwICt- 1/16/03 T J.- Maj 25 04-04:16p LONEGAN FIDELITY NATIONALI — LE COMPANY SUBDIVISION DEPARTMENT WHEN RECORDED MAIL TO: Michael & Catherine Lonegan 50855 Washington Street PMB 220 La Quinta, CA 92253 MAIL TAX STATEMENT TO: SAME AS ABOVE 760 564 5089 p.2 08/2012003 08:00A Fee:16.0a Page I of 4 Doc T Tax Paid Recorded in Official Records County Of Riverside Gary L. Orso Assessor, County Clerk & Recorder 111111111111 pill IIII 1111111111111111111 oil 11111111 M U PAGE SLZE DA P -go' NOCOR -WF A R L COPY LONG 1 REFUND NCHG EXAM DOCUMENT TRANSFER TAX $ $346.50 XX Computed on the consideration or value of property conveyed; OR Computed on the consideration or value less liens or encumbrances JkH—j remaining at the time of sale. ft- 7701-,�50 Signature of Declarant or Agent determining tax — Firm Name To - on, -0�5(0 GRAAT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND LA QLTINTA PARTNERS, LLC, a Delaware limited liability company ("Grantor"), hereby GRANT(S) to NUCHAEL LONEGAN AND CATHERINE LONEGAN, HUSBAND AND wIFE, AS JO]NT TENANTS ("Grantee'), the real property located in the City of La Quinta, County of Riverside, State of California, described as: See Legal Description attached hereto and incorporated herein as Exhibit "A". SUBJECT TO all matters of record including, without limitation,* the covenants and agreements described in Exhibit "A" attached hereto. Dated: July 10, 2003 ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company By. Nationwide Realty Investors, Ltd. an Ohio hmitej)�ability com any 'y its managii �gmber B y: JosepVL.,�renson' Authorized Representative 4- Maj 25 04 04:16p LONEGAN STATE OF'California . -) )ss. COUNTY OF. Riverside 760 564 5089 . P.3 2003, before me, the undersigned, a notEry public in and for 1__St�ate, p �rsonallyapp�eared oseph L. Arenson, authorized representatve of Nationwide Realty Investors, Ltd., (whose identity was proved to me on the basis of satisfactory evidence) to be the person whose name is subscribed to the within instrument and acknowledged to -me that he executed the same in his autho ' rized *capacity, and that by his signattze on the instrument the person, or the entity upon behalf of which the person acted, executed the instrument. WITNESS MY HAND AND OFFICLALL SEAL, —[SEAL] Signature Conn1E Concetto comm. #1417229 Z NOWZY PUPIC - CAUFORNLA Z Cn RNERSDE COUNW *my Comfftss1ors1M*es MaV 11, 2007t 25 04 04:17p LONEGnN .760 564 5089 p.4 EXHIBIT"A" Legal Description Parcel No. 1: Lot 198 (the "Lot") of Amended Tract No. 29894-2 as shown on Subdivision Map (the 'Nap") recorded on December 12, 2002, in Book 327, Pages 56 to 88, inclusive, of Maps in the Office of the Riverside County Recorder.. EXCEPTING AND RESERVING THEREFROM TO GRANTORand its successors, assigns, invitees, licensees and employees, together with the right to grant and transfer all or a portion of the same, all easements and rights for access, ingress, egress, encroachment, - maintenance, drainage, support, and for other purposes over the Association Mairteriance Areas and other portion of the Lot, reserved to Grantor in the following instruments: I The Amended and Restated Declaration of Covenants, Conditions and Restrictions and Reservation of Easements for The Hideaway Owners Association (as amended or supplemented, the "Declaration'), recorded on December 13, 2002, as Instrurnent No. 2002- 745939, of Official Records of Riverside County, California (the "Official Records"); 2. . The Supplementary Declaration of Annexation of Property, re'cord--d on March 21, 2003, as Instrument No. 2003-201647, of Official Records of Riverside Coun-ZY, California. FURTHER RESERVING THEREFROM, the right to enter the La for a term of twelve (12) months following the recordation. of this Grant Deed, to complete an(� repair any improvements or landscaping located thereon as detemiined necessary by Granto' r ' in its sole discretion, in order to comply with requirements for the recordation of the Final Tract Map, the grading of said Tract and/or in compliance with the requirements of applicable gcvernmental agencies. Such entry by Grantor shall be preceded by reasonable notice to Grantee before such entry. If this reservation of right of entry is not complied with by Grantee, Grantor may enforce this right of entry in a court of law. Grantee shall be responsible for all damages arising out of said breach including attorneys' fees and court costs. This reservation of right ofentry shall automatically expire twelve (12) months from the recordation of this Grant Deed - FURTHER RESERVING THEREFROM, an easement for landscaping purposes over the Southeasterly 11.5' feet thereof Parcel No. 2: Nonexclusive easements for access, ingress, egress, drainage, maintenarica, repairs and for other purposes, all as described in the Declaration. 2 03 99 88/20/ 3 f) of 1 4 ': clef' 1111 1E I Ma�j 25 04 04:17p LONEGAN 760 564 5089 P.5 SUBJECT TO: 1. - Non delinquent general, special and supplemental real property tax -2s and assessments. 2. All other covenants, conditions, restrictions, reservations, easemems, rights and rights-of-way of record including, without imitation, the Declaration and the Map:for Tract No. 29894-2. Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in this Grant Deed, (b) grants to Grantor and The Hideaway Owners Association such powers and rights as are set forth in the Declaration, anc'(c) accepts, covenants and agrees to be bound by and assume performance of all of the applicF-ble provisions and requirements set forth in the Declaration, including Section 13.15 establishing the procedure for resolving disputes with Grantor, and the notice, which provisions and requirements are acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be performed by Grantee under the Declaration. The restrictions on use and occupancy of the Lot are set forth in the Declaration to which this Grant Deed is specifically and expressly made subject. GRANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING- granting unto Grantor and The Hideaway Own s Association such powers and rights which are set forth in the Declaration defined above, on 2003. Nfichael Lone an STATE OF CALIFORNIA )ss. COUNTY OF RIVERSIDE WMA ' "3, before me, the unders.--gned, a notary publici=­d'f�o� 2dStatepersonally ael Loneg a*n and Catherir-,e Lon egan, personally known to me (or proved to me on the basis of satisfactory evidence) to be the persons whose names are subscribed to the within instrument and ackno . wledged to me thF-t they executed the same in'their authorized capacities,. and that by their signature on the instrument the persons, or the entity upon behalf of which the persons acted, executed the instrument. WrINESS My HAND AND OFFICIAL SEAL. [SEAL] Signature -4-of 4- Connie Concetto COMK#1417229 Z U N.OTARY PU IUC - CALIFORNIA MV�R-'IDE COUNTY IPMYComminbr Exp1res Mcy 11, 2007t A A9116, Am Contractor ALPHA OMEGA Permit Number 04-4825 POST ON JOB IN CONSPICUOUS PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES JOB ADDRESS 80-2SO VIA PESSARO 3750 SQ. -FT. SFD. TH-i3p PERMIT DOES NOT INCLUDE POOL & SPA BLOCK WALLS OR DRIVEWAY APPROACH. . TYPE OF INSPECTION DATE INSE�___ TEMPORARY POWER SETBACKS 5- -2 U/G PLUMBING /WASTE U/G ELECTRICAL / GROUiiD—ING FOOTINGS / STEEL CONCRETE SLAB DO NOT POUR CONCRETE UNTIL ABOVE SIGNED ROOF NAIL/ PRE -ROOF 0 6 OKAY TO WRAP FRAMING (COMBINATION) ROUGH ELECTRIC ROUGH PLUMBING ROUGH MECHANICAL INSULATION COVER NO WORK UNTIL ABOVE SIGNE INTERIOR GYP BD. (DRYWALL) I EXTERIOR LATH GAS TEST 2 -�2-7 SEPTIC ABANDONMENT SEWER CONNECTION 6— SEPTIC / GREASE INTERCEPTOR f MASONRY INSPECTIONS FOOTINGS / STEEL 'e2� - BONDBEAM d - f2y - (9.1,1 uo�l POOL / SPA / WATER FEATURE INSPECTIONS PRE-GUNITE / SETBACKS U/G PLUMBING U/G US U/G qLECTRICAL PRE-PLACTER (ALARMS/ BARRIERS) FINAL INSPI TEMP USE OF PERMANENT POWER ELECTRICAL PLUMBING MECHANICAL PUBLIC WORKS DEPARTMENT COMMUNITY DEVELOPMENT DEPT. FINAL / JOB COMPLETED ABOVE APPROVALS DO NOT INCLUDE RIGHT TO' - TURN ON UTILITIES OR OCCUPY BUILDING to. C? r OF Owner lcf 6 CITY BUILDING INSPECTION RE00M 777-7153 NoGRAIL lbeNEe*N Ga' -1 Contractor ALPHA OMEGA 9.r - Permit Number 05-2845 POST ON JOB IN CONSPICUOUS PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES JOB ADDRESS 80-280 VIA PESSARO 434 L.F-. 6' GARDEN WALL, ORCO SYSTEM TYPE OF INSPECTION I DATE I INSR TEMPORARY POWER SETBACKS U/G PLUMBING /WASTE U/G ELECTRICAL/ GROUNDING FOOTINGS / STEEL CONCRETE SLAB DO NOT POUR CONCRETE UNTIL ABOVE SIGNED FRAMING (COMBINATION) R011r.H PI F(TPlr. ROUGH PLUMBING p()I lrlw MF:r.HANlr.Al COVER NO WORK UNTIL ABOVE SIGNED INTERIOR GYP BD. (DRYWALL) EXTERIOR LATH GAS TEST SEPTIC ABANDONMENT SEWER CONNECTION' SEPTIC / GREASE INTERCEPTOR MASONRY INSPECTIONS FOOTINGS / STEEL BOND BEAM POOL / SPA / WATER FEATURE INSPECTIONS PRE-GUNITE / SETBACKS U/G PLUMBING U/G GAS U/G ELECTRICAL PRE -PLASTER (ALARMS/ BARRIERS) FINAL INSPECTIONS TEMR USE OF PERMANENT POWER ELECTRICAL PLUMBING MECHANICAL PUBLIC WORKS DEPARTMENT COMMUNITY DEVELOPMENT DEPT. FINAL / JOB COMPLETED ABOVE APPROVALS DO NOT INCLUDE RIGHT TO TURN ON UTILITIES OR OCCUPY BUILDING M 0 Certificate of Occupancy 4 LWOMM, 0 Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance ' this structure was Jn compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction andlor use. BUILDING ADDRESS: 80-280 VIA PESSARO Use classification: SINGLE FAMILY DWELLING Building Permit No.: 04-4825 Occupancy- Group: R3 Type of Construction: VN Land Use Zone: RL Owner of Building: MICHAIL LONEGAN Address: 50-855 WASHINGTON ST City, ST, ZIP: LA QUINTA, CA 92253 By: STEVE R. WILLETT Date: MARCH 01, 2006 Building Officia I POST IN A CONSPICUOUS PLACE MA TITLE 24 REPORT Title 24 Report for: Lot #198 @ "The Hideaway" Lot #198 @ "The Hideaway" La Quinta, CA 92253 Project Designer: Gordon Ross 42-829 Cook Street, Suite #204 Palm Desert, CA 92260 (760) 568-1712 Report Prepared By: Ci Mcfadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 cl-rf 0 LA Q '' I)A3 6-0855 0' 7, - 3 " )A Q' 'V _, F ' �IFETY DEP . 6-1 L� VED BUILDING & SAFETY DEFT. CTIO APPROVEI) F )R 0 OR CONST UCTION C) Y u um mber: Date: 7/29/2004 I The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by. EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number: 3665 OFF16 I tin .2ast CjV- I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 6 Form C -2R Computer Method Summary 8 Form ENV -3 Proposed Construction Assembly 13 HVAC System Heating and Cooling Loads Summary 15 Room Load Summary 17 Room Heating Peak Loads 19 Roo m Cooling Peak Loads 21 En.rgyPro 3.1 By EnergySoft Job Number: User Number. 3665 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Lot #198 (cD- "The Hideaway" 7/29/2004 Project Title Date Lot #198 (d) "The Hideaway" LaQuinta Project Address Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check I Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 2,950 f? Total Conditioned Slab Area: 2,950 f? Average Ceiling Height: 11.7 ft Building Type: Frame Type (check one or more) Location/Comments (attic, garage, typical, etc.) K Single Family Detached 0 Addition El Single Family Attached D Existing Building Multi -Family Existing Plus Addition Front Orientation: (Southeast) 135 deq . Floor Construction Type: Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 E] Raised Floor Component Type Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) R-38 Roof (R.38.204.16) Wood 0.028 Exterior Roof W-1 Wall (W.21.2x6.16) Wood 0.057 Exterior Wall W-2 Wall (W.21.2x6.16) Wood 0.057 Exterior Wall Solid Wood Door Wood 0.387 Exterior Door Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation . Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes No Right (Northeast) 182.0 0.35 0.38 Bug Screen 0 0 El 0 Right (Northeast) 10.0 0.38 0.30 Bug Screen El El 0 FRI Front (Southeast) 84.0 0.50 0.49 Bug Screen El lil 1:1 0 Front (Southeast) 26.4 0.35 0.38 Bug Screen El El El Z Left (Southwest) 42.7 0.50 0.49 Bug Screen 1:1 1:1 El Left (Southwest) 13.2 0.35 0.38 Bug Screen [R] El [g] Rear (Northwest) 96.0 0.50 0.49 Bug Screen 191 n [91 Rear (Northwest) 57.0 0.35 0.38 Bug Screen 0 [K] El 191 Left (Southwest) 15.0 0.38 0.30 Bug Screen 1:1 R1 0 El Rear (Northwest) 156.0 0.53 0.36 Bug Screen 0 El 1:1 191 1:1 0 El F-1 1:1 El 0 n Run Initiation Time: 07/29/04 07:29:52 Run Code: 1091111392 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:3 of 24 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Lot #198 (cD- "The Hideaway" /29/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Desigi Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Conments rpntr;;l Furnnnp 80% AFLIE Ducts Attic 42 qpth;;rk — HVAC -1 (Right Wang) rpntr.gi Eurnare 80% AFUE ntict- Attor 42 Setback — HVAG--2-(Left.VVAnq) Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type - Conments Split Air Conditioner 14.0 SEER - Ducts in Attic 42 qpth;;rk HVAC -1 (Riaht Wing Split Air Conditioner 14 Q SEER Dur'tq in Attic 42 qpth;;rk HVAC -2 (Left Wing) WATER HEATING SYST EMS Rated Tank Energy Fact! External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss I(%) R -Value A-0 SMITH FCG-100-1 Large Gas Rer0rc1T0me+Temp— 1 75 1QQ 100 078 oboon .00 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and StanCby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with -itle 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Gordon Ross Address: 42-829 Cook Street, Suite #204 Palm Desert, CA 92260 Telephone: (760) 568-1712 Lic �. #' � 6 �' /p/ /' /0 � 2 t mfi -wz-- -- ��? �96 �� (signature-) '- a (date)lf Enforcement Agency Name: Title/Firm: Address: Telephone: Name: CJ Mcfadden Title/Firm: BREEZE AIR CONDITIOWING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 922-1 Telephone: (760) 346-0855 ,// -71.-�q frA (signature) !0' 1 (bate) lEnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:4 of 24 1 I L Certificate of Compliance: Residential (Addendum) CF -1 R Lot #198 (a')- "The Hideaway" 7/29/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These iterrs require special written justification and documentation, and special verification to be used with the performance approach. The local onf--nnt m onr riatarminac fho nriamint--v nf the iti-qtifiratinn- and rnav raiect a buildino or desion that otherwise comDlies based on the adequacy of the special justification and documentation submitted. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 450 sqft Tile in Mortar Interior Mass, 0.75" thick at Master/Guest/Foyer/Hall HIGH MASS Design(see C -2R) - Verify Thermal Mass: 450 sqft Exposed Slab Floor, 3.50" thick at Master/Guest/Fo�er/Hall HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1068 sqft Covered Slab Floor, 3.50" thick at Master/Guest/Fcyer/Hall HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1289 sqft Tile in Mortar Interior Mass, 0.75" thick at Great Rro/Dining/Kitchen HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1289 sqft Exposed Slab Floor, 3.50" thick at Great Rm/Dininc/Kitchen HIGH MASS Design(see C -2R) - Verify Thermal Mass: 143 sqft Covered Slab Floor, 3.50" thick at Great Rm/Dining/Kitchen HERS Required Verification Thp-qp fpattirpq muqt hp rnnfirmpri and/nr tp-qtpd hv a certified HERS rater under the sunervi�ion of a CEC aooroved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a itorm GF -6R. --Flan Field The HVAC System "HVAC -1 (Right Wing)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2 (Left Wing)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 07/29/04 07:29:52 Run Code: 1091111392 E-nergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:5 of 24 Mandatory Measures Checklist: Residential (Page I of 2) MF -1 R �OTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance appro2ch used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. WhEn this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. CESIGNER ENFORCEMENT Building Envelope Measures 1XI 1150(a): Minimum R-19 ceiling insulation. E] § 1 50(b): Loose fill insulation manufacturers labeled R -Value. §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). F]*§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perrn/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. F] § I 50(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures [X] §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA orACCA. § 1 50(i): Setback thermostat on all applicable heating and/or cooling systems. X] § 1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-1 2 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-1 2 external insulation or R-1 6 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:6 of 24 Mandatory Measures Checklist: Residential' (PageA2 of 2) MF -1 R �OTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach ised. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When t)is checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specificati 3ns for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION instructions: Check or Initial applicable boxes or enter N/A If not applicable. DESIGNER JENFORCEMENTI Space Conditioning, Water Heating and Plumbing System Measures: (continued) FV1 § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CIVIC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL1 81, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2, Building cavities, support platforms for air handlers, and plenums defined or constructed with materials. other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. F—] 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. 17X § 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) E] §118 (f): Cool Roof material meet specified criteria Lighting Measures §1 50(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. 1A I § 1 50(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. L 3.1 By EnergySoft User Number- 3665 Job Number: Page: 7 of 24 I I I I I I Computer Method Summary (P a 11 of 3) C -2R I . "Thp Hide-awav" R-38 Roof (EL3a2x1 4.16) 38W-WaLLOAL91 7YA 161 [ X /gnn4 Project Title X El -W--LZW=2J 26.1.6.') Date t :9 R eawav" La-Guinta X El F Project Address 0 M- -ZWLW-2J-2)(6 16 X I Buildirg Permit# RREE7F AIR ',OND=NIRG--- (760) 346-0855 A Documentation Author 6-1-6) D -Q Telephone Plan Cieck/Date -Computer Performance El ML�-1-WaIL(VY-21 9YF; 16) 15 F1 Field Check/Date Compliance Method (Package or Computer) F-1 Climate Zone F-1 Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin F-1 Space Heating 3.52 3.72 -0.20 F-1 Space Cooling 36.76 39.24 -2.48 Domestic Hot Water 9.66 6.51 3.15 17 Totals 49.94 49o47 0.47 El Percent better than Standard: 0.9% Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name 2,950 ft2 Floor Construction Type: [:] Raised Floor Slab Floor Single Fam Detached (Southeast) 135 deg Total Fenestration Area: 23.1 % 3 1.00 Total Conditioned Volume: 34,555 1 Total Conditioned Slab Area: 2,950 ft 2 # of Floor Area Volume Units Zone Type 1±VAC---1-(1Right Wing) 151R 15 93 0 r.1 rnnflition rl ±tVAC--Z(Left-Wnq) 114 11161 0-49 ----Comiit0oned OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Roof --J_5-JB- 0,0z8- 0 Wall 217 ---D-057- 45 - An -WAIL-- 244 ---0-057- 45 go W:;Il —23A ----U57- 135 90 Wall .56- 0,057 135 90 D-o-ar 24 Q 387 135 Wall —265 ---O-Q57_ 225 90 -Wall ----ZO-6- --OM7 315 ---9Q -Wall 23 ---LL57- 315 - c)Q ]Roof— I 43Z ---DM8- --3A5- 0 Wall —3E --O-Q57- 45 —90- -W -all— ----96 —0-1157- 135 ----aO Wall— —353 --O-Q57- 92S - 90 Wa I 1— —325 0,057 315 - 90 Solar Gains Y/N Form 3 Reference X I X- 0 El R-38 Roof (EL3a2x1 4.16) 38W-WaLLOAL91 7YA 161 [ X D W-2 Wall (01-91 9Y6, 161 X El -W--LZW=2J 26.1.6.') X 0 -\8L2-ZLaIL(ZL212x6 16) X El -salid-Wopd-Door X 0 M- -ZWLW-2J-2)(6 16 X El 0 W-1 W UW -2-L2 VV -2 wal 91 9,,r, j6) R-3-8-Ro4R-a8-2xL4.1&)-- -W---1-W-a1L(\81-2J 2)(r. 161 A 0 6-1-6) D -Q El 26,16) [N El ML�-1-WaIL(VY-21 9YF; 16) F-1 F1 El F-1 F-1 F� F-1 F1 M F-1 F1 F-1 17 F-1 F-1 F-1 F-1 F-1 F� F� F-11 17 F-1 F-1 El F-1 E-VAG-1 NWETSM1111 HVAC -1 EVAC--2- HVAr.-9 EVAC-9 Run Initiation Time: 07/29/04 07:29:52 Run Code: 1091111392 Thermostat Vent Type Hgt. Area —aatback— n ---Setback— n Location / Comments I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paqe:8 of 24 1 Computer -Method Summary (Part 2 of 3) C -2R Lot #198 g "The Hideaway" 7/29/2004 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Loca'tion/ # Type Area Factor SHGC Azm. Tilt Comments -I- Window--JRigbL--(Noffhaast) inn 0350 n -iB 45 90 SJeTra-Ractf1c-Cdad-(LoLE)-- HVAC -1 2 Window Right (Northea t) 10.0 0.350 0.38 45 90 Sierra Pacific Clad (Lo/E) HVAQ-1 3 Window Right (Northea t) 54.0 0.350 0.38 45 90 Sierra Pacific Clad (Lo/E) HVAQ-1 4 Window Right (Northea t) 54.0 0.350 0.38 45 90 Sierra Pacific Clad (Lo/E) HVAC -1 5 Window Right (Northea t) 54.0 0.350 0.38 45 90 Sierra Pacific Clad (Lo/E) HVAC -1 6 Window Right (Northeast) 10.0 0.380 0.30 45 90 Sierra Pacific Clad (Lo/E) HVAQ-1 7 Window Front (So-uAheast) 36.0 0,500 0.49 135 90 Sierra Pacific Clad (Lo/E) HVAQ-1 8 Window Front t) 5.0 0.350 0.38 135 90 Sierra Pacific Clad (Lo/E) HVAC -1 9 Window Left (Southwest) 42.7 0,500 0.49 225 90 9'erra Pacific Clad (Lo/E) HVAC -1 JD, Window Left (Southwest) 4.0 0,350 0.38 225 90 Sierra Pacific Clad (Lo/E) HVAC -1 11 Window Rear (Northwe t) 48.0 0.500 0.49 315 90 Sierra Pacific Clad (Lo/E) HVAQ-1 12 Window Rear (Northwe t) 21.4 0.350 0.38 315 90 Sierra Pacific Clad (Lo/E) HVAC -1 J-3 Mad [ont st) ---0-0 0-500 0,,49 135 90 Sierra Pacific Clad-(LoJE)-- HVAQ-2 14 Window Front (Sou heast) 21.4 0.350 0.38 135 90 Sierra Pacific Clad (Lo/E) HVAQ-2 15 Window Left (Southwest) 2.3 0.350 0.38 225 90 Sierra Pacific Clad (Lo/E) HVAQ-2 16 Window Left (Southwest) 2.3 0.350 0.38 225 90 Sierra Pacific Clad (Lo/E) HVAQ-2 17 Window Left (Southwest) 2.3 0.350 0.38 225 90 Sierra Pacific Clad (Lo/E) HVAQ-2 18 Window Left ISouthwest) 15.0 0.380 0.30 225 90 Sierra Pacific Clad (Lo/E) HVAC -2 -L9 Window Left (Southwest) 2.3 0,350 0.38 225 go SjffLa-���� HVAQ-2 20 Window Rear (Northwest) 21.4 0.350 0.38 315 90 Sierra Pacific Clad (Lo/E) HVAC -2 21 Window Rear (Northwest) 48.0 0.500 0.49 315 90 Sierra Pacific Clad (Lo/E) HVAC -2 22, Window Rear (Northwe t) 156,0 0,530 0,36 315 90 Sier,a Pacific Clad 'Lo/E, -90 HVAQ-2 23 Window Rear (Northwest) 14.2 0.350 0.38 i-15 Sierra Pacific Clad (Lo/E) HVAC -2 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fir- Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. I -Ext. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug, Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bu Screen 0.76 5 Bug Screen 0.76 Bug Screen 0.76 7 Buo Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 8.0 5.3 8.0 0.1 8.0 8.0 10 Bug Screen 0.76 - - - - - 11 Bug Screen 0.76 12 Bug Screen 0.76 T3 Bug Screen -dug 0.76 T4 Screen 0.76 T5 Iffug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen -dug 0.76 T8 Screen -dug -076 T9 Screen -076 20 �!ug §�creen 0476 21 Bug Screen 0.76 22 Bug Screen 0.76 10.0 15.5 10.0 0.1 10.0 10.0 23 0.76 Run Initiation Time: 07/29/04 07:29:52 Run Code: 1091111392 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:9 of 24 Computer Method Summary (Part 3 of 3) C -2R Lot #198 (a-)- "The Hideaway" 7/29/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN PERIMETER LOSSES Area Thick. Heat Type Length Inside Locallion Type (sq (in.) Cap. Cond. Form 3 Reference R -Val. Comments Tile in MQrtar 450 -1125 24 -O-EZ nLa— 0 HVAC -1 / Interior Mass Concrete, HeaMeight 450 3.50 28 0.98 n/a 0 HVAC -1 / Slab on Grade -C-QnjcLete-±te_a-v�� 1,068 3.50 28 0.98 n/a 2 HVAQ-1 / Slab on Crade Tile in Mortar 1,289 0,75 24 0.67 n/a 0 HVAG�2 / Interior Mass -Co.ncre1P--H.eAmywRdgb.t— 1,289 -3 J50. --2-8 -QM n/a 0 HVAC: -2 /,91ab on Grade PERIMETER LOSSES HVAC SYSTEMS Heating Equipment F2 Insulation Type Length Factor R -Val. Depth Location / Comments 2ab Perimeter 18 0.76 0.0 0 HVAC -1 -SJab-Eenrne.teL— --159 -QJ6 --U 0 HVA.C-1 j— 90 -5La-l;LEemmWe 0.76 0.0 ---Q HVAQ-2 -SJab-Bedme1eL— 1 -026 —0-0 —D HVAC -2 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (air conditioner, Type (furnace, heat Efficiency and Location Duct Thermostat Location pump, etc.) (AFUE/HSPF)(ducts/affic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -1 (Ro ht Win Central Furnace 80.% AFUE Ducts in Attic 4.2 Setback HVAC -2 (Left Wing) Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments lit Air CQnditioner 14.0 SEE Ducts in Attic 4.2 Set�ack HVP-Q-1 , S lit Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAQ-2 (Left Wing) WATER HEATING SYSTEMS Rated' Tank Energy !Fact! 1 TankInsul. Water Heater Water Heater Distribution # in Input Cap. or Reccvery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficierr-y Loss (%) Ext. A.0. SMITH FCG-100-1 L3cgg-Qaa— Recirc/Time+Temp— 1 75,100 100 0.73 --- UO -Q— 0.0 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Locs. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Computer Method Summary (part 3 of 3) C -2R Lot #198 P_ "The Hideaway" 7/29/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Localion Type (sD (in.) Cap. Cond. Form 3 Reference R -Val. Com-nents .QQncrete. Heavvwe'qht 143 -aM --28. -U8. n/;; 2 HVAC -2 I Slab-Dn-G-rade- PERIMETER LOSSES F2 Insulation Type Length Factor R -Val- Depth Location / Comments HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location pump, etc.) (AFUE/HSPF)(ducts/attic: etc.) R -Value Type Como ments Pipe Pipe Insul. Hydronic Piping System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Cornments WATER HEATING SYSTEMS Ratedl Tank Energy Factl TankInsul. Water Heater Water Heater Distribution #in Input Cap. or Reccovery Standby R -Value System Name Type Type Syst. (Btu/hr) (cial) Efficiency Loss (%) Ext. For small gas storage (rated input �= 75010 Blulhr), electric resistance and heat pump water heaters, list energy factor-, For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. EnergyPro 3.1 By EnerqySoft User Number: 3665 Job Number Panp- i I nf 24 1 Computer Method Summary (Addendum) C -2R Lot #198 (5- "The Hideaway" 7/29/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. 1he local A.+-;- 0- M #h* hiefifientinn nnrl mnv raipt-t n hiflidinn nr dpninn that nfl-,erwisa cnmnlies based on the adequacy of the special justification and documentation submitted. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 450 sqft Tile in Mortar Interior Mass, 0.75" thick at Master/GLest/Foyer/Hall HIGH MASS Design(see C -2R) - Verify Thermal Mass: 450 sqft Exposed Slab Floor, 3.50" thick at Master/Guest/Fower/Hall HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1068 sqft Covered Slab Floor, 3.50" thick at Master/Guest/Foyer/Hall HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1289 sqft Tile in Mortar Interior Mass, 0.75" thick at Great Rr-i/Dining/Kitchen HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1289 sqft Exposed Slab Floor, 3.50" thick at Great Rm/Dining/Kitchen HIGH MASS Design(see C -2R) - Verify Thermal Mass: 143 sqft Covered Slab Floor, 3.50" thick at Great Rm/Dining/Kitchen HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field The HVAC System "HVAC -1 (Right Wing)" includes Refrigerant Charge and Airflow Credit (or a TXV.). A certified HEFS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2 (Left Wing)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HEFS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 07/29/04 07:29:52 Run Code: 1091111392 E-nergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 12 of 24 I 1PROPOSED CONSTRUCTION ASSEMBLY ENV -31 II PROJECT NAME Lot #198 "The Hide DATE 7/29/2004 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) 1CONSTRUCTION COMP DESCRIPTION ASSEMBLY NAME 1W-1 Wall (W.21.2x6.16) ASSEMBLY Floor OUTSIDE SURFACE AIR FILM I stucco TYPE Wall Mernbrane, Vapor -Permeable Felt 3 (check one) 4 Insulation, Mineral Fiber, R-21 Ceiling / Roof Gypsum or Plaster Board W 0.31 7 a FRAMING MATERIAL 2.60 —9 0.68 z 0. FRAMING % % Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) 1CONSTRUCTION COMP THICK- NESS (in.) 0.875 0.010 0.375 5.500 0.625 SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM I stucco 2 Mernbrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.31 7 0.37 8 2.60 —9 0.68 INSIDE SURFACE AIR FILM THICK- NESS (in.) 0.875 0.010 0.375 5.500 0.625 SUBTOTAI R -VALUE CAVITY R -VALUE (Re) WOOD FRAME R -VALUE 0.170 0.170 0.1751 0.175 0.060 0.060 0.465 , 0.465 21.000 5.445 0.5621 0.562 0.31 2.63 0.37 0.98 2.60 0.26 0.68 0.680, .0.680 1 23.111 Kc KT A - I B *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/s-) SPECIFIC HEAT (Btu/F-lb) HC (A X B) (Btu/F-sf) members. I 8A6 0.20 1.69 0.06 0.35 0.02 1.06 0.29 0.31 2.63 0.37 0.98 2.60 0.26 0.68 14.81 TOTAL HC COMMENTS EnergyPro 3.1 By Energy i User Number. 3665 Job Number: 13 of 24 NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the frz.ming members. I x 0.85 1 r-1 + 0.13231 — x I I Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE COMMENTS EnergyPro 3.1 By Energy i User Number. 3665 Job Number: 13 of 24 1PROPOSED CONSTRUCTION ASSEMBLY ENV -73 PROJECT NAME Lot #198 a "The Hideaway" DATE 7/29/2004 PONENT DESCRI SKETCH OF ASSEMBLY UCTION DESCRIPTION FRAMING LU I Gypsum or Plaster Board 2 Insulation, Mineral Fiber, R-21 3 Cn 4 z 0 260 SKETCH OF ASSEMBLY UCTION ASSEMBLY NAME IW -2 Wall W21.2x6.16) ASSEMBLY Floor TYPE Wall (check one) Ceiling Roof FRAMING MATERIAL FRAMING % % Framing % DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM I Gypsum or Plaster Board 2 Insulation, Mineral Fiber, R-21 3 Gypsum or Plaster Board 4 0.37 5 260 6 0.68 7 8 9 INSIDE SURFACE AIR FILM ASSEMBLY NAME IW -2 Wall W21.2x6.16) ASSEMBLY Floor TYPE Wall (check one) Ceiling Roof FRAMING MATERIAL FRAMING % % Framing % SUBTOTAI] R -VALUE THICK- NESS (in.) FRAMING El FX El 1:1 El El Cl El El 0.170 0.625 5.500 0.625 5.445 0.562 0.562 0.37 0.98 260 0.26 SUBTOTAI] R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.5621 0.562 21.000 5.445 0.562 0.562 0.37 0.98 260 0.26 0.68 0.680 0.680 22.981 Rc Rf 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) 7% (24" o.c. Floor/Ceil.) A *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/s.) SPECIFIC, HEAT (Btu/F-lb) HC (A X B) (Btu/F-sf]I x 0.85 260 0.26 0.68 263 0.37 0.98 260 0.26 0.68 ----778 TOTAL HC NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. x 0.85 F-, + 0.13481 x 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paqe: 14 of 24 1 I 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY 1PROJECT NAME DATE I Lot #198 @ "The Hideaway" 7/29/2004 ISYSTEM NAME FLOOR AREA HVAQ-1 (Riqht Wing) 1,518 N SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD CFM I Sensiblel Latent I I CFM I Sensible 1 1,8881 35,7851 4,30� 1 6741 27,319 0 1,789 1,366 0 0 114 4,335 5,576 -0 0 1,789 1,366 43,699777�� F7:�� AVAC EQUIPMENT SELECTION HS26-060/G40UH60C-1 10 (5) 45,812 6,835 89,400 Total Adjusted System Output (Adjusted for Peak Design Conditions) 1 45,8121 6,835] 89,40�O TIME OF SYSTEM PEAK Aug 2 pm] Jan 12 anril HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 24.0 OF 66.8 OF 108.2 OF 108.2 OF )0 -.1 %. 4 � Sl-pply Air Outside Air 114 cfm 107.6 OF Heating Coil Supply Fan 2000 cfm ROO 70.0 OF 69.4 OF I 1E ;11111� i Air Ducts "c' OOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 114.1 / 80.3 OF 80.8 / 66.4 OF 59.6 / 58.2 OF 59.6 / 58.2 OF Supply Air Outside Air 1 114 cfm Cooling Coil Supply Fan 60.4 / 58.5 OF 1 .4 � 2000 cfm 50.7% R.H. R00M-q I ! 78.8 / 65.5 OF 78.0 / 65.2 OF �% Return Air Ducts 14 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae: 15 of 24 1 I L 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY I PROJECT NAME DATE Lot #198 @ "The Hideaway" 7/29/2004 ISYSTEM NAME FLOOR AREA I- HVAC -2 (Left Wing) - 1,432 NGINEERING 24.0 OF Outside Air 107 cfm 69.5 OF 14.1 / 80.3 OF Outside Air 107 cfm 78.8 / 65.5 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Utent CFM I Sensible 42,875F 6,83�8 IHS26-060/G40UH60C-110 (5) 45,575 7,069 89,400 Total Adjusted System Output (Adjusted for Peak Design Conditions) 45,5751 7=0 69 F 89.40]0 TIME OF SYSTEM PEAK F- Aig 2 prn Jan 12 aml HROMETRICS (Airstream Tel 67.0 OF 0 108.4 OF Heating Coil 80.7 / 66.4oF res at 108.4 OF SLpply Air 7� Supply Fan 107.9 OF 2000 cfm ROOMS 70.0 OF Return Air Ducts n 59.6 / 58.2 OF 59.6 / 58.2 OF Air Ducts ue, Supply Fan 60.4 / 58.5 OF 2000 cfm 519% R.H. ROOM 78.0 65.3 OF Return Air Ducts Cooling Coil EnergyPro 3.1 By EnergySoft User Number: 3665 1 Job Number: Paqe: 16 of 24 35,258 0 __23,5�9O 1,763 1,180 0 0 4,091 2,15]6 5,270 -0 0 L-- 1,7631 42,875F 6,83�8 IHS26-060/G40UH60C-110 (5) 45,575 7,069 89,400 Total Adjusted System Output (Adjusted for Peak Design Conditions) 45,5751 7=0 69 F 89.40]0 TIME OF SYSTEM PEAK F- Aig 2 prn Jan 12 aml HROMETRICS (Airstream Tel 67.0 OF 0 108.4 OF Heating Coil 80.7 / 66.4oF res at 108.4 OF SLpply Air 7� Supply Fan 107.9 OF 2000 cfm ROOMS 70.0 OF Return Air Ducts n 59.6 / 58.2 OF 59.6 / 58.2 OF Air Ducts ue, Supply Fan 60.4 / 58.5 OF 2000 cfm 519% R.H. ROOM 78.0 65.3 OF Return Air Ducts Cooling Coil EnergyPro 3.1 By EnergySoft User Number: 3665 1 Job Number: Paqe: 16 of 24 ROOM LOAD SUMMARY PROJECT NAME Lot #198 @ "The Hideaway" DATE 7/29/2004 SYSTEM NAME HVAC -1 (Right Wing) FLOOR AREA 1, 518 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING DEAK COIL HTG. PEAK ZONENAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -1 Master/Guest/Foyer/Hall 1 1,888 35,785 4,301 1,888 35,785 4,301 674 27,319 PAGE TOTAL TOTAL 1 1,8881 35,7851 4,30111 6741 277,3719] 1 1,8881 35,7851 4,30,11 6741 27,3191 I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 17 of 24 1 ROOM LOAD SUMMARY PROJECT NAME Lot #198 @ "The Hideaway" DATE 7/29/2004 SYSTEM NAME HVAC -2 (Left Wing) FLOOR AREA - 1,432 [ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING DEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -2 Great Rm/Dining/Kitchen 1 1,858 35,258 4,683 1,858 35,258 4,683 577 23,590 PAGE TOTAL TOTAL 1 1,8581 35,25a, 1 4,683]1 5771 23,590 1 1,8581 35,2581 4,683]1 5771 23,5901 I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 18 of 24 1 0 ROOM HEATING PEAK LOADS �Project Title Date Lot #198 n "The Hideaway" �7/29/2004 Room Information Design Conditions I Room Name Master/Guest/Foyer/Halll Time of Peak Jan 12 am Floor Area 1,518 � Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value 2nT 0 F Btulhr Items shown with an asterisk (*) denote conduction through an interior surface to another room. Page Total: 20,723 Infiltration: chedule x Air Sensible x Area x Ceiling Height x ACH 60] x dw 6,596 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 27,319 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 19 of 24 1,518.0 X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 1,955 921.9 0.0566 46.0 1401 212.4 0.3500 46.0 3,420 10.0 0.3800 46.0 175 523.0 0.0572 46.0 1,376 126.7 0.5000 46.0 2,914 24.0 0.3872 46.0 427 perimeter 177 - 0 45.5 8,054 Items shown with an asterisk (*) denote conduction through an interior surface to another room. Page Total: 20,723 Infiltration: chedule x Air Sensible x Area x Ceiling Height x ACH 60] x dw 6,596 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 27,319 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 19 of 24 ROOM HEATING PEAK LOADS I Date "The Hideaway" �7/29/2004 Room Information Design Conditions Room Name Great RmlDining/Kitchen Time of Peak Jan 12 am Floor Area 1,432 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF I Conduction Area U -Value AT OF Btu/hr R-38 Roof (R.38.2xl4.16) 1,432.0 x 0.0280 X 46.0 1,845 W-1 Wall (W.21.2x6.16) 808.8 x 0.0566 x 46.0 2,107 -Si-e.ica-P—a-r.ifLc—Clid-(Lo/F-) 96.0 x 0.5000 x 46.0 2�208 Sierra Pacific Clad (Lo/6 66.2 x 0.3500 x 46.0 1,066 .Sjeua-P—ac&c-Mad-(LcLF) 15.0 x 0.3800 x 46.0 262 Sierra Pacific Clad (Lo/E) 156.0 x 0,5300 x 46.0 3,803 Slab -On -Grade perimeter 10 1. 0 x x 45.5 4,596 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x X. x x x x x x x x Items shown with an asterisk denote conduction through an interior surface to another room. Page Total: 15,886 Infiltration: IT x x - x X 0.50 60] x Schedule Air Sensible Area Ceiling Height ACH IL -T Fraction 17 —TOTAL HOURLY HEAT LOSS FOR ROOM 23,5901 0 By EnergySoft User Number: 3665 Job Number: Page:20of24 771 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #198 P "The Hideaway" 7/29/2004 - Project Title Date IRoom Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Master/Guest/Foyer/Hall 780F 115 0 F 370F Conduction Area U -Value :)ETD 1 Btu/hr x x x x x x X. - x x x x x x x x 56.0 = = = = = = = 2,381 35.6 1,858 37.0 2,751 37.0 141 35.6 1.065 37.0 2. 35.6 (Southeast) x x 1. Design Equivalent Temperature Difference (DETD) P�age Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. I Shaded Unshaded a. Solar Gain Orientation Area SGIF Area SGIF Sc Btu/hr I L FxdGisWdw (F2) (Northeast) Fxd-GJ (Northeast) FxdGIsWdw (E3) (Northeast) FxdGIsWdw (El) (Northeast) FxdGIsWdw (E2) (Northeast) CsmntWdw (Dl) (Northeast) SvvnqG1sEntryDr (1) (Southeast) Fxd G1sWdvv (N 1) (Southeast) IFrnchDr (2) (Sout west) lFxdGIsWdw (81) (Southwest) 0.0 (-0.0 x x x x x x x x X x :::All 15 + + + + + + + + + + 10.0 x X x x x x x X X x 48)X )X )xF -0.423 = = = = = = = = - 10.0 48)x 0.423 203 0.0 54.0 4 0.423 1,096 0.0 15 54.0 48)x 0.423 1,096 0.0 15 54.0 48)x 0.423 1,096 0.0 15 10.0 48)X 0.334 160 15 36.0 62)X 0.545 1,218 A0.0 0.0 15 1 5.0 62)X 0.423 131 42.7 0.0 62)X 0.545 -0423= 349 15 4.0 F 105 Sched. Fage Total Internal Gain Frac. Area - Heat Gain Btu/hr Lights 1.00 X 1,518 0.500 Wafts/sqft x 3.413 BtuhfWatt 2,5901 Occupants 1.00 X 1,518 X 250 Btuh/occ. / 200 scliftlocc. Receptacle 1.00 x 1.518 x 1.500 Watts/scift x 3.413 BtuhfWaft Process 1.00 x 1,518 x 0.000 Watts/sqft x 3-41 BtuhfWatt Infiltration: x [::] 7o - - -:::37 8-J x =1528 x [:::] 5 5 -o-� x [�o /6q] E:- [::::x Schedule Air Sensible Area Ceiling Height ACH Fraction FOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 35,7851 Sched. Latent Gain Frac. Area Heat Gain Btu/hr �Occupants 1.00 x x 200 Btuhlocc. If 200 Sqft/OCC. Re-ceCCU 1.00 X x 0.000 Wafts/sqft x 3.413 BtjhfWatt = ptacle iProcess 1.00 x x 0.000 Wafts/sqft x Btih[Watt = Infiltration: F=]I� x x x x 60] 0-00433 Schedule Air Latent Area Ceiling Height ACH W Fraction [TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,301 By EnergySoft User Number: 3665 Job Number: Page: 21 of 247 I I I I I RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #198 (.3 "The Hideaway" 7/29/2OC4 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value x 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (*) denote conduction through an interior surface to another room Shaded Solar Gain Orientation Area SGIF FrnchDr (10) (Northwest) 0.0 x 15 + Exd-GlqWfiw (U) (Northwest) 0.0 x 15 + 435 x + x + x + x + -)x x + - x + x + XP+ Master/Guesb`Foyer/Hall 780F 115 0 F 370F Fage Total Btu/hr Unshaded Area X X x x x X x x x x SGIF )x )X )X )X 1).x )x )X SIC = = Btu/hr 48.0 48)!� 0.545 1,257 21.4 48)x 0.423 435 -)x F:� - Sched. Page Total Internal Gain Frac. Area Heat Gain 1 Btu/hr Lights 1.00 X 1,518 X 0.500 Watts/sqft x 3.413 Bt-ih[Waft 2,590 Occupants 1.00 X 1,518 X 250 Btuhlocc. 2 2 sqft/occ. 1,898 00 Receptacle 1.00 x 1,518 x 1.500 Watts/sqft x ��3.4��13 Btuh[Waft 7,771 Process 1.00 x 1,518 x 0.000 Watts/sqft x 3.411 Btuh[Waft 0 Infiltration: x =08� x [=5181 x =0-5� x E=� 6q] E=2 E=ii� chedule Air Sensible Area Ceiling Height ACH Fraction -- - FOTAL HOURLY SENSIBLE HEAT GAINFOR ROOM 35,7851 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants x x 200 Btuh/occ. if 200 scft/occ. x x 0.000 Watts/sqft : 3.41� Btuh[Watt = iProcess [A x x 0.000 Watts/sqft x 1 3.41 Btuh[Watt = Infiltration: chedul e x Air Latent x Area x Ceiling Height x ACH 60] Fraction ITOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,301 FEnergyP,, 3 1 By EnergySoft User Number: 3665 Job Number: Page: 22 of 24 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #198 (�D "The Hideaway" 7/29/2004 Project Title Date Room Name Great Rm/Dirflng/Kitchen Design Indoor Dry Bulb Temperature: 780F Design Outdoor Dry Bulb Temperature: 115 0 F Design Temperature Difference: 370F Conduction W-1 Wal�l (W.2 &;;�;Cific ierra Pacific bierra Pacific Area U -Value DETD' x 56.0 x 35.6 x 37.0 x 37.0 x 37.0 x 37.0 x x x Btu/hr 2,246 1,630 1,776 857 211 3,059 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. I Shaded Unshaded Solar Gain Orientation Area SGIF Area SGIF SIC Btu/hr FrnchDr (14) (Southeast) Exd_G1 (H-4) FxdGIsWdw (H3) - (Southeast) _ (Southwest) FxdGIsWdw (H2) (Southwest) FxdGisWdw (H1) (Southwest) CsmntWdw (G3) (Southwest) FxdGisWdw (132) (Southwest) FxdGIsWdw (131) (Northwest) FrnchDr (13) (Northwest) SldqGlsDr (12) (Northwest) 0.0 X x x x x x X x x x 1� + + 11 + + + + + + + 48.0 X X x x x x x X X x 62'x x X x x X 0.545 = = = = = = = = 1,623 0.0 15+ 21.4 62'x 0.423 561 0.0 ils 2.3 62'x 0.423 60 0.0 1 2.3 62'x 0.42 60 0.0 1 2.3 62 0.423 60 0.0 15 15.0 62- 0.334 311 0.0 15 2.3 62, 0.423 60 0.0 15 21.4 48..x 0.423 435 0.0 15 48.0 48: 0.54 1,257 0.0 15 48'� 0.40 3,001 Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,432 X 0.500 Watts/sqft x 3.41 BtuhfWaft 2,444 Occupants 1.00 X 1 432 X 250 Btuh/occ. / 200 scft/occ. 1,790 Receptacle 1.00 x 1,432 x 1.500 Watts/sqft x 3.413 BluhfWatt 7,331 Process 1.00 x 1,432 x 0.000 Watts/sqft x 3.41 BtuhfWaft 0 Infiltration: x =!�J x =:�jA3 x EL�,3_o x =,,5 60] E�__3 =_:�;2 Air Sensible Area Ceiling Height ACH �T Fraction [TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 35,2581 Sched. latent Gain Frac. Area Heat Gain Btu/hr !Occupants x x 200 Btuh/occ. 200 sqft/occ. lReceptade x x 0.000 Watts/scIft x 'A 41 �, 131 u h/Watt = iProcess A x x - Q On Watts/sqft x 3.4131 BluhtWatt = Infiltration: 1 1.001 X 4.13401 X x x 60] C.00433J itent Area Ceiling Height ACH Fraction ITOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,6831 i - lEnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 23 of 24 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #198 P "The Hideaway" 7/29/2004 Project Title Date .1 Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction I I F Area U -Value x Great RrrVC)ir�ing/Kitchen 780F 115 0 F 370F Btulhr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGIF Area SGIF SIC Btu/hr FxdGIsWdw (N2 Aby.) (Northwest) 0.0 x — 15 + 14.2 x 4 )X 0.423 288 x + x )x x + x —)x x + x )-x x + x x + x )-X x + x )X x + x DIX x + x )X x + x I)X Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Li-ghts 1.00 x 1,432 X 0.500 Wafts/sqft x 3.413 Btjh[Waft 2,444 Occupants 1.00 X 1,432 x 250 Btuh/occ. 202 scgt/occ. 1,790 0 1 Receptacle 1.00 x 1,432 X 1.500 Wafts/sqft x �34� �1 3 BtjhfWaft 7,331 Process 1.00 x 1,432 x 0.000 Watts/sqft x 3.41 _ Btih[Watt 0 Infiltration: x x x E:��—�o x E=—,aol/ 60] E=3 Air Sensible Area Ceiling Height ACH Fraction FOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 35,258 Sched. Latent Gain Frac. Area Heat Gain Btu/hr 10ccupants 1.00 x x 200 Btuh/oc sqft/occ. I Receptacle 1.0 x x 0.000 Watts/sqft x Btah[Watt = iProcess 1.00 x x 0.000 Watts/sqft x Btuh[Watt = Infiltration: F-1---010 x x x x 60] Schedule Air Latent Area Ceiling Height ACH —AV Fraction FOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,683] iEnergyPro 3.1 By EnergySoft --- User Number: 3665 Job Number: Page: 24 of 24 1 L TITLE 24 REPORT Title 24 Report for: Lot #198 @ "The Hideaway" (Guest House) Lot #198 @ "The Hideaway" La Quinta, CA 92253 Project Designer: Gordon Ross 42-829 Cook Street, Suite #204 Palm Desert, CA 92260 (760) 568-1712 Report Prepared By: CJ Mcfadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 Job Number: Date: 7/29/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. TI-P.s program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Ene-gy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number: 3665 I TABLE OF CONTENTS I Cover Page Table of Contents. Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary Form ENV -3 Proposed Construction Assembly HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 6 8 12 14 15 16 17 I EnergyPro 3.1 By EnergySoft Job Number: User Number: 3665 1 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Lot #198 "The Hideaway" (Guest House) 7/29/2004 -Project Title Date Lot #198 "The Hideaway" LaQuinta Project Address Building Permit# BREEZE AIR CONDITIONING (760) 346-0855 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check i Date Compliance Method (Package or Computer) Climate Zone— EnforcEment Agency Use Only GENERAL INFORMATION Exterior Roof Total Conditioned Floor Area: 850 f? Average Ceiling Height: 9.5 ft Total Conditioned Slab Area: 850 ft' Building Type: Exposed Slab w/R-0.0 Perimeter Insuletion (check one or more) Covered Slab w/R-0.0 Perimeter Insul.lion K Single Family Detached El Addition 0 Single Family Attached El Existing Building 0 Multi -Family 0 Existing Plus Addition Front Orientation: (Northwest) 315 de -q Floor Construction Type: Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 Raised Floor Component Const. Frame Assembly Location/Comments Tvpe U -Value (attic, garage, typica , etc.) R-38 Roof (R.38.2xl4.16) Wood W-1 Wall (W.21.2x6.16) Wood W-2 Wall (W.21.2x6.16) Wood Slab On Grade n/a Slab On Grade n/a FENESTRATION 0.028 Exterior Roof 0.057 Exterior Wall 0.057 Exterior Wall 0.756 Exposed Slab w/R-0.0 Perimeter Insuletion 0.756 Covered Slab w/R-0.0 Perimeter Insul.lion U -Factor SHGC Shading Yes / No Yes No Left (Northeast) 40.0 Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes No Left (Northeast) 40.0 0.35 0.38 Bug Screen F-1 0 1:1 [y] Rear (Southeast) 20.0 0.35 0.38 Bug Screen 1-1 [K] 1:1 0 Rear (Southeast) 15.0 0.37 0.32 Bug Screen 1:1 IRI 1:1 0 Right (Southwest) 20.0 0.35 0.38 Bug Screen 1:1 Fx� El Z Front (Northwest) 42.8 0.35 0.38 Bug Screen 1:1 El 0 0 Front (Northwest) 96.0 0.50 0.49 Bug Screen F� FKI El [91 El 0 El F-1 El F I El F-1 F] El n El 1:1 El Q 1:1 1:1 El Run Initiation Time: 07/29/04 07:41:08 Run Code: 1091112068 EnergyPro 3.1 By EnerqySoft User Number: 3665 — Job Number Page:3 of 18 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R 'Lot #198 (cD- "The Hideaway" (Guest House) 7/29/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Desion Heating Load. Gordon Ross Address: Distribution Palm Desert, CA 92260 Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Co lIments rpntr;il Furnnra 80% AFLIE — Ducts On Att*r 4.2 Setback HVA��-1 (Guest Canota) Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 14 0 SEER Ducts In Attic 4 9 Setback HVA:.' -1 (Guest Cnqitn) WATER HEATING SYSTEMS Rated 1 Tank Energy Fwt External Water Heater Water Heater Distribution # in Input Cap. or Recove.-y Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A-0. SMITH FCG-75-1 Large Gas Standard 1 7.9 inn 75 0-78 0,0000 .0-0 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Stardby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has beem signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Gordon Ross Address: 42-829 Cook Street, Suite #204 Palm Desert, CA 92260 Telephone: (760) 568-1712 Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: EnergyPro 3.1 By EnergySo User Number: 3665 (date) Name: CJ Mcfadden Title/Firm: BREEZE AIR CONDITIONING Address: .75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 -7 11-4 (signature) �2(d�a Job Number: of 18 I 11 I I I I E Certificate of Com2liance: Residential (Addendum) CF -1 R Lot #198 (cD "The Hideaway" (Guest House) 7/29/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. Ihe local enforcement aaencv determines the adequacv of the justification, and may reject a building or design that otterwise complies )ased on the adequacy of the special justification and documentation submitted. I Plan I Field HERS Required Verification Thp-qp fpabirp-z mtiqt hp ennfirmpd andInr tpqtpri hv a rprtifipd HERS rater undAr the sunarvision of a CEC anryoved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on aform GF -6R. —� I —an Field The HVAC System "HVAC -1 (Guest Casita)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1 (Guest Casita)" is using reduced duct leakage to comply and must have diagnostic site testi-ng of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paqe:5 of 18 1 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures [X] 1150(a): Minimum R-19 ceiling insulation. § 1 50(b): Loose fill insulation manufacturer's labeled R -Value. 1150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). [].*§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. [XI §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certificaflon. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150ft Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. X§150(e): Gas Installation of Fireplaces, Decorative Gas Appliances and Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § 1 50(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. FY -1 § 1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-1 2 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-1 2 external insulation or R-16 combined internaltextemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paqe*.6 of 18 Mandatory Measures Checklist: Residential (Page 2 of 2) MFA R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When t-iis checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specificatons for the mandatory measures whether they are shown elsewheire in the documents or on this checklist only. IDESCRIPTION instructions: Check or initial applicable boxes or enter N/A If not applicable. DESIGNER JENFORCEIVIENT itioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CIVIC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautornatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. \/ I F X-1 §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118 (f): Cool Roof material meet specified criteria Lighting Measures lFV7 § 150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for ^ I general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting I control panel at an entrance to the kitchen. FX_1 §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. I ___1 3.1 By EnergySoft User Number: 3665 Job Number. Page: 7 of 18 Computer Method Summary (P a rt 1 of 3) gt-2R 1 ot CAR @ "Thp Hideaway" (Gui--,t Hni mm-) M;af;l ..- . . . 1 1.1 /gnn4 Project Title — I ry Thp Hideawav" La Quinta I Date Project d reiis' Building Permit# RREE7F AIR CONDITIONING (760) 346-0855 -Plan Documentation Author Telephone C ieck/Date Computer Performanrp- 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin_ Space Heating 3.92 3.78 0.14 Space Cooling 48.29 47.14 1.15 Domestic Hot Water 24.11 13.83 10.28 Totals 76.32 64.75 11.57 Percent better than Standard: 15.2% Total Conditioned Floor Area: 850 ft 2 Building Type: Single Farn Detached Building Front Orientation: (Northwest) 315 deg Number of Dwelling Units: 1.00 Number of Stories: 1 Floor Construction Type: [] Raised Floor EX] Slab Floor Total Fenestration Area: '927.5% Total Conditioned Volume: 8,075 ft' Total Conditioned Slab Area: 850 ft 2 BUILDING ZONE INFORMATION # of Th �rmostat Vent Zone Name Floor Area Volume Units Zone Type 7ype Hgt. Area HVAG-1 ( uest r;Wta) RFM 807 1 an rnnrlutmonpri ;Pthark n/ OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Roof —8-5D 0,02-8 345 0 -wall— 269 ---0-057- 45 ---90- wall 24, 11,57- 135 go -Vall J-0- --O-Q57- 225 —90 -Wall 6.4 0,057 225- ----9a -Wall 171 n n-57 90 Solar Gains Y/N Form 3 Reference Location / Comments .Guest-Sudeq 1 19 .Guest Ruit s 1 19 G11Pqt,q-fltPq 1 ;� 2 =GueSt-CA&es 1 12 -Guest-Suite-q I k 2 jGuest quites, I -% 9. - EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paoe:8 of 18 1 M;af;l ..- . . . 1 1.1 =TAT21i WATF1 I RVATAVA W4.7-15 1-1 MTAT&ATATFI I WAWA W4.7 -M N Location / Comments .Guest-Sudeq 1 19 .Guest Ruit s 1 19 G11Pqt,q-fltPq 1 ;� 2 =GueSt-CA&es 1 12 -Guest-Suite-q I k 2 jGuest quites, I -% 9. - EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paoe:8 of 18 1 Computer Method Summary (Part 2 of 3) C -2R Lot #198 P_ "The Hideaway" (Guest House) 7/29/2004 Project Title Date FENESTRATION SURFACES # Type Area U_ Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments _1_ \&inrin Left (Northeast) 10.0 0150 n3a _____45_ 90 Sierra Pacific G1ad_(L&E)__ _Gme f Si J Pq 1 P 9 2 Window Left (Northea t) 10.0 0.350 0.38 45 90 Sierra Pacific Clad (Lo/E) Guest Suites 1 & 2 3 Window Left (Northea t) 10.0 0.350 0.38 45 90 Sierra Pacific Clad (Lo/E) Guest Suites 1 & 2 4 Window Left (Northea t) 10.0 0.350 0.38 45 90 Sierra Pacific Clad (Lo/E) Guest Suites 1 & 2 5 Window Rear (Southeast) 10.0 0.350 0.38 135 90 Sierra Pacific Clad (Lo/E) Guest Suites 1 & 2 6 Window Rear (Southeast) 15.0 0.370 0.32 135 90 Sierra Pacific Clad (Lo/E) Guest Suites 1 & 2 1- Window Rear _(S-outbiast) 10.0 0,350 0.38 90 56erra Pacific Clad (Lo/E) Guest 3uites_1_&_2_ 8 Window Right (Southw st) 10.0 0.350 0.38 225 90 Sierra Pacific Clad (Lo/E) Guest Suites 1 & 2 k- ��w �i ht (Southwest) 10.0 0,350 0.38 225 90 .. rra Pacific Clad (Lo/E) Guest Sui es 1 & 2 _M W_ndP_w__f _rQnL__(NQ0hw.Qst) 21.4 0,350 0.38 315 90 Sierra Pacific Clad (Lo/E) Guest 9uites 1 & 2 11 Window Front (Northwe t) 48.0 0.500 0.49 315 90 Sierra Pacific Clad (Lo E) Guest Suites I & 2 12 Window Front (Northwe t) 48.0 0.500 0.49 315 90 Sierra Pacific Clad (Lo/E) Guest Suites 1 & 2 -1-3. Wi ad st) 214 Q-350 EA.& _315- 90 Si.eaa_Eaadc_Mad_(LaLE)__ _Gme51-auites 1 & 2 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 - - - - - - - - - - 2 Bug Screen 'Bug 0.76 - - - - - - - - - - S_ Screen 0.76 4 Bug Screen 0.76 5 __ Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen Iffug 0.76 -9 Screen 0.76 gug Screen 0.76 10 _� _1 Bug Screen -dug 076 Screen -076 �_2 Iffug Screen -076 T3 _ffug Screen -076 EnergyPro 3 1 User Number: 3665 Job Number: of 18 Computer Method Summary (Part 3 of 3) C -2R. Lot #198 a "The Hideaway" (Guest House) 7/29/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Type (s� (in.) Cap. Inside Loca� ' ion Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES Type (furnace, heat Efficiency and Location F2 Insulation Type Length Factor R -Val. Depth Location Comments -slab-Ew=etef- 13 076 00 0 -Slab-BefimeteL- 112 -Q.7-6. --D-O 0 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%-AEU.F-- Ducts in Attic 4.2 Se back HVA.C-1 (Guest Casita) Pipe Insul. Hydronic Piping Pipe System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments -$p-ftA4r-Con-dAiipner 14.0 SEE Ducts in Attic 4.2 Setback HVAQ-1 (Guest Casita) WATER HEATING SYSTEMS Ratedl Tank Energy FacO 1 Tankinsul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.0. SMITH FCG-75-1 Laig-e-G—as $tandard 1 75,100 75 O. -C 8 0,0000 0.0 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factoir. For large gas storage water heaters (rated input > 75000 Btulhr), list Rated Input, Recovery Efficiency and Standby Lcss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Comput-er Method Summary (Addendum) C -2R Lot #198 a- "The Hideaway" (Guest House) 7/29/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement auencv determines the adeauacv of the iustification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. I Plan I Field I HERS Required ' Verification Thaca fantitrac miect ho t-nnfirmarl nnrlinr tp--torl hv n rprtifiprf HFRR rater tinclar the stinarvision of a CEC anr roved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form GF -6R. --P—lan Field The HVAC System "HVAC -1 (Guest Casita)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1 (Guest Casita)" is using reduced duct leakage to comply and must have diagnostic site! testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 11 of 18 1 1PROPOSED CONSTRUCTION ASSEMBLY E N V -:3] PROJECT NAME Lot #198 @ "The Hideaway" (Guest'House) DATE 7/29/2004 1 DESCRIPTION El El 1:1 R -VALUE DESCRIPTION WOOD FRAME R -VALUE ASSEMBLY NAME ASSEMBLY IW -1 Wall (W.21.2x6.16) Floor Stucco 2 Nembrane, Vapor -Permeable Felt 3 Plywood TYPE (check one) Wall 5 Gypsum or Plaster Board 6 0.31 7 Ceiling RD& 8 2.60 9 0.68 FRAMING MATERIAL INSIDE SURFACE AIR FILM 0 z FRAMING % % Framing % TOTAL HC 15% (16** o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) El El 1:1 R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Stucco 2 Nembrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.31 7 0.37 8 2.60 9 0.68 INSIDE SURFACE AIR FILM El El 1:1 R -VALUE CAVITY R-VALLIE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.175 0.175 0.060 0.060 0.465 0.465 21.000 5.445 0.562 0.562 0.31 2.631 0.37 0.98 2.60 0.26 0.68 0.680 SUBTOTAq 23.111 Rc Rf *HEAT CAPACITY (Optional) WALL WEIG-iT (Ibs/sf) SPECIFIC HEAT (Btu/F-lb) HC (A X B) (Btu/F-sf) x 0.85 8.46 0.20 1.69 -0.06- -0.35 0.02 1.06 0.29 0.31 2.631 0.37 0.98 2.60 0.26 0.68 TOTAL HC NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. x 0.85 + I-, 0.13231 x L 0.15 11 1 / Rc 1 - (Fr*/6 /100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 12 of 18 1 I ,IPROPOSED CONSTRUCTION ASSEMBLY IPROJECT NAME Lot #198 (�� "The Hideaway" (Guest House) AUT&I DATE 7/29/2004 1CONSTRUCTION COMPONENTS TTHICK] I SS NESS DESCRIPTION WOOD FRAME R -VALUE ASSEMBLY NAME ASSEMBLY IW -2 Wall (W.21.2x6.16) Floor Gypsum or Plaster Board 2 Insulation, Mineral Fiber, R-21 3 Gypsum or Plaster Board TYPE 'Wall 5 le.60 6 0.68 (check one) x L 0.15 8 9 I I Rc I - (Fr% / 100) Ceiling R-3of 0.68.0 ASSEMBLY U -VALUE 0 LU U) 0 FRAMING MATERIAL I-- U) 0 z FRAMING % % Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) 1CONSTRUCTION COMPONENTS TTHICK] I SS NESS F"MINGI El 0.625 [X 5.500 El 0.625 El El El 0 0 1:1 R-VALIJE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM I Gypsum or Plaster Board 2 Insulation, Mineral Fiber, R-21 3 Gypsum or Plaster Board 4 0.37 5 le.60 6 0.68 7 x L 0.15 8 9 I I Rc I - (Fr% / 100) INSIDE SURFACE AIR FILM F"MINGI El 0.625 [X 5.500 El 0.625 El El El 0 0 1:1 R-VALIJE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.5621 0.562 21.000 5.445 0.562 0.562 0.37 0.98 le.60 0.26 0.68 + 0.13481 x L 0.15 I I Rc I - (Fr% / 100) 0.680, 0.68.0 ul��U- *H-EAT CAPACITY (Optional) WALL WEIG-IT (Ibs/sf) SPECIFIC HEAT (Btu/F-lb) HC (A X B) (Btu/F-sf) Rf 2.60 0.26 0.68 2.63 0.37 0.98 le.60 0.26 0.68 + 0.13481 x L 0.15 I I Rc I - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE COMMENTS SUBTOTAI] 22.981 --7742 7.81 TOTAL HC Rc Rf *NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. x 0.85 + 0.13481 x L 0.15 I I Rc I - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE COMMENTS EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 13 of 18 IHVA'C SYSTEM HEATING AND COOLING LOADS SUMMARY I 1PROJECT NAME DATE I Lot #198 @ "The Hideaway" (Guest House) 7/29/2004 ISYSTEM NAME FLOOR AREA HVAC -1 (Guest Casita) 850 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD CFM I Sensiblel Latent I I CFM I Sensible 1 1,076 21,9591 2,26011 4151 17,054 0, 1,0�8 853 0 0 2,426 1,476 1 64 3,121 .0 0 1,098 853 1 26,58� 37736 F 218-801 HS26-036/G40UH36A-70X (3) 29,107 2,841 54,100 Total Adjusted System Output (Adjusted for Peak Design Conditions) 29,1071 9m, TIME OF SYSTEM PEAK Aug 2 PM] Jan 12 arni HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 24.0 OF 66.9 OF 108.7 OF 108.7 OF 40 ="M 01' ) � Supply Air Outside Air --Ir 64 cfm 108.0 IF Heating Coil Supply Fan 1200 cfm ROOMS 70.0 OF 69.3 IF Return Air Ducts 1COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 114.1 / 80.3 OF 80.7 65.6:)F 58.3 56.8 OF 58.3 56.8 OF Supply Air Ducts 7� Outside Air 64 cfm Cooling Coil Supply Fan 59.1 / 57.1 OF 1200 cfm L7.8% R.H. ROOM 78.8/64.6 0 F 78.0 . 164.4 OF �% Return Air Ducts ',A I rznergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paqe: 14 of 18 1 ROOM LOAD SUMMARY PROJECT NAME Lot #198 @ "The Hideaway" (Guest House) DATE 7/29/2004 SYSTEM NAME HVAC -1 (Guest Casita) FLOOR AREA 850 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Guest Suites 1 & 2 Guest Suites 1 & 2 1 1,076 21,959 2,260 1,076 21,959 2,260 415 17,054 PAGE TOTAL TOTAL 1 1,0761 21,959 4151 1 1 1,0761 21,959 2,26011 4151 17,0541 I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 15 of 18 1 i ROOM HEATING PEAK LOADS I toject Title Date Lot #198 Ob- "The Hideaway" (Guest House) �7/29/2004 Room Information Design Conditions I Room Name Guest Suites 1 & 2 Time of Peak Jan 12 am Floor Area 850 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value 2LT OF Btu/hr f Items shown with an asterisk (*) denote conduction through an interior surface to another room. Page Total: Infiltration: I L'�S—chedule x Air Sensible x Area x Ceiling Height x ACH 160] x &T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 17,054 F —EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 16 of 18 850.0 X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 891.2 0.0566 46.0 2,321 122.8 0.3500 46.0 1,977 15.0 0.3700 46.0 255 EA.0 0.0572 46.0 168 96.0 0.5000 46.0 2,208 perimeter 125.0 45.5 5,688 Items shown with an asterisk (*) denote conduction through an interior surface to another room. Page Total: Infiltration: I L'�S—chedule x Air Sensible x Area x Ceiling Height x ACH 160] x &T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 17,054 F —EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 16 of 18 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #198 15 "The Hideawa Guest House) 7/29/2OC4 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-38 Roof (R.38.2xl4. W-1 Wall (W.21.2x6.11 Sierra Pacific CladjLo ierra Pacific Clad (Lo -2 Wall (W.21.2x6.11 ierra Pacific Clad (Lo Area U -Value x ,Guest.Suites 1 & 2 78OF 115 0 F 370F DETD 1 x 56.0 x 35.6 x 37.0 x 37.0 x 35.6 x x x x Btu/hr 1,333 1,797 1,590 205 130 1776 1. Design Equivalent Temperature Difference (DETD) Fage Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGIF Area SGIF SIC Btu/hr FxdGIsWdw (M3) (Northeast) Exd-G1sXA1dw-(M2) - (Northeast) _ FxdGisWdw (1-1) (Northeast) FxdGisWdw (K2) (Northeast) FxdGIsWdw (Ml) (Southeast) Vert.Sldr (Kl) (Southeast) lFxdGIsWdw (A) (Southeast) FxdGIsWdw (13) (Southwest) FxdG]sWdw (12) (Southwest) FxdGisWdw (11) (Northwest) 0.0 x x x x x x x x x x 15 + + + + + + + + , + 10.0 x X x x X x x x X X 4 )X �x �X �x 0.42 = = = = = = 203 o.6 15 10.0 4 0.423 203 0.0 15 10.0 48 0.42 203 0.0 15 10.0 48 0.423 203 0.0 15 10.0 62)x 0.423 262 0.0 1z) 15.0 62)X 0.356 331 0.0 151+ 1� 10.0 62)x 0.423 262 0.0 -10.0 62)X 0.423 262 0.0 -00 1 ::A,, 10.0 62)x 0.423 262 21.4 48)x 0.423 435 Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 850 0.500 Watts/sqft x 3-41 � BtjhfWatt 1,451 Occupants 1.00 X 850 X 250 Btuh/occ. 290i sqft/occ. 1,062 00 Receptacle 1.0 x 850 x 1.500 Watts/sqft x �34� 13 Bt-jh[Waft 4,352 .Process 1.00 x 850 x 0.000 Wafts/sqft x 3.41 _ Btuh[Watt 0 Infiltration: X =�810 x =8501 x x [=J 60] E=3� =:��8 Schedule Air Sensible Area Ceiling Height ACH Z -\f Fraction FOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,959 Sched. Latent Gain Frac. Area Heat Gain Btu/hr loccuipants - 1.00 X x 200 Btuh/occ. scft/occ. [Receptacle - 1.00 x x 0.000 Watts/sqft x 3.413 Btuh[Waft = [Process 1.00 x x 0.000 Watts/sqft x 3.41 Btuh/Watt = Infiltration: x E 4.8401 x x x 60] 1 01004 1,410 Air Latent Area Ceiling Height ACH L4V Fraction ITOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,2601 lEnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 17 of 18 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #198 0 "The Hideaway" (Guest House) 7/29/2004 Project Title Date IRoom Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Guest Suites 1 & 2 780F 115 0 F 370F Conduction Area U -Value DETD' Btu/hr x x x x x x X - x x 1. Design Equivalent Temperature Difference (DETD) Page Total items shown with an asterisk denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGIF Area SGIF SC Btu/hr FrnchDr (15) (Northwest) 0.0 x 15 + 48.0 x 4 )X - 0:545 = .1,257 .F:mrhnr (16) (Northwest) 0.0 x 15 + 48.0 X 4 )x 0.545 = 1,257 FAGIsMw (M4) (Northwest) 0.0 x 15 + 21.4 . x 4 X 0.423 = 435 x + x x x + x -)x x + X )x x + x -)x x + x )x x + x )X I t I XL + I X )X Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 850 0.500 Watts/sqft x 3.41 Btuh[VVaft 1,451 Occupants 1.00 X 850 X 250 Btuh/occ. / 200 sqft/occ. 1,062 Receptacle 1.00 x 850 X 1.500 Watts/sqft x 3.41 BtuhtWatt 4,352 Process 1.00 x 850 x 0.000 Watts/scift x 3-412 Btuh[Watt 0 Infiltration: x =� x x =:97m x =Qpo 60] Schedule Air Sensible Area Ceiling Height ACH T Fraction FOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,959 Sched. Latent Gain Frac. Area Heat Gain Btuihr 10ccuipants 1.00 x x 2001 Btuhlocc. sqft/occ. 1 1.00 x x 0.000 Watts/sqft x BtuhNVatt = lProcess 1.00 x x 0.0001 Watts/sqft x -Btuh[Watt = Infiltration: x x x x 60] 1 0.004 —Schedule Air Latent Area Ceiling Height ACH Fraction FTOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,260 JEnergyPro 3.1 By EnergySoft User Number: 3665 Job Number'. Page: 18 of 18 1