Loading...
07-0424 (SFD)` ' P.O. BOX 1504 1$495 CALLE TAMPICO LA ;QUINTA, CALIFORNIA 92253 T4ht- 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 07-00000424 Owner: Property Address: 80260 VIA PESSARO GARY FRANA APN: 772-550-013- - - 53-749 VIA PISA Application description: DWELLING - SINGLE FAMILY DETACHED LA QUINTA, CA 92253 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 3498'/1 Applicant: . Architect or Engineer: I ----------------- LICENSED CONDOR'S, DECLARATION 1 hereby affirm under penalty of perjury t f I amI' ed under br ' ions of Chapter 9 (commencing with Section 7000) of Division 3 of the Busi s and r ssiona a and my License is in full force and effect. License Class: B / i s No.: 886137 . Date: Contractor: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she. is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not ap6ly to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 I am exempt under Sec. ' , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT VOICE (760) 777-7012 .FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/28/07 Contractor: LA QUINTA BUILDERS LOOZ 4 d3S 79785 TANGELO LA QUINTA, CA 92253 a (760)771-5378 V Lic. No.: 886137 ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier REDWOOD FIRE POlic ber W7637812 I certify that, in the performance of th ork r which this permit is issued, I shall not employ any person in any manne as to ome subj t to the workers' compensation laws of California, and agree that, if I o d bec lec the workers' compensation provisions of Section of the Labor od , 1 sh II orthwit omply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes nu and voi if work is not commenced within 180 days from date of issuance of such permit, o cessation �f work for 180 days will subject permit to cancellation. I certify that I have read this application and state that th bove i rmation is orrTct. 1 agree to comply with all city and county ordinances and state laws relating to b di g con n he by authorize representatives of this cWtt /enter upon the above-mentioned prop y or in ction p. os Date: �v�Signature (Applicant or Agent): LQPERMIT Application Number . . . . . 07-00000424 ------ Structure Information 3,982SF DWELLING/V-NR/RES-3/CLASS A -FR ----- Other struct info CODE EDITION 2001/2005 # BEDROOMS 3.00 FIRE SPRINKLERS NO GARAGE SQ FTG 850.00 .PATIO SQ FTG 862.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE.FOOTAGE 357.5.00 2ND FLOOR SQUARE FOOTAGE 407.00 Permit . . Additional desc . Permit Fee . . . Issue Date . . . Expiration Date . BUILDING PERMIT 1514.50 2/24/08 Plan Check Fee . . 984.43 Valuation . . . . 349871 Qty Unit Charge Per Extension BASE FEE 639.50 250.00 ---------------------------------------------------------------------------- 3.5000 THOU BLDG 100,001-500,000 875.00 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . .. 186.37 Plan Check Fee 46.59 Issue Date Valuation . . . . 0 Expiration Date 2/24/08 Qty Unit Charge Per Extension BASE FEE 15.00 3982.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 139.37 850.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 17.00 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . Additional desc . Permit Fee Issue Date . . . . Expiration Date . . GRADING PERMIT 15.00 2/24/08 Plan Check Fee . . .00 Valuation . . . . 0 Qty Unit Charge Per . Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Permit . . . MECHANICAL Additional desc . Application Number . . . . . 07-00000424 f Permit . . . . . . MECHANICAL Permit Fee . . . . 156.00 Plan Check Fee 39.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 2/24/08 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 2.00 11.0000 EA MECH FURNACE >100K 22.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 2.00 9.0000 EA MECH B/L z-3NP/100K BTU 28.00 2.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 33.00 6.00 6.5000 EA MECH VENT FAN 39.00 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 213.00 Plan Check Fee 53.25 Issue Date . . . . Valuation . . . . 0 Expiration Date 2/24/08 Qty Unit Charge Per Extension BASE FEE 15.00 22.00 6.0000 EA PLB FIXTURE 132.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 4.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 12.00 6.00 .7500 EA PLB GAS PIPE >=5 4.50 1.00 - 15.0000 EA PLB GAS METER 15.00 --------------- Special Notes ----------=------------------------------------- and Comments ------------ 3,982 SF DWELLING/V-NR/RES-3/CLASS A-FR. THIS PERMIT DOES NOT INCLUDE BLOCKWALLS, POOL AND SPA, OR DRIVEWAY APPROACH. August 28, 2007 2:34:50 PM aortega ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES-RES 374.67 DIF COMMUNITY CENTERS-RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 98.44 DIF FIRE PROTECTION-RES 140.00 GRADING PLAN CHECK FEE 15.00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 LQPER 11T Application Number . . . . . 07-00000424 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . .DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 34.98 . DIF STREET MAINT FAC-RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary ----------------- Charged -7 -------- Paid Credited ------------------------------ Due Permit Fee Total 2084.87 .00 .00 2084.87 Plan Check Total 1123.27 500.00 .00 623.27 CJLIieL° Fee TuLdl 4998.09 .00 .00 4998.09 Grand Total 8206.23 500.00 .00 7706.23 LQPEFJMT Building Address 0 Owner Tittiv 4 4 Cv v-?- L/2 P.O. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO QM_Afn LA QUINTA, CALIFORNIA 92253 Malang Address ���--� k ��� C'ty Zip Tel. 3 9-- `fS 1.3 C2= r ^^ t �j }L�y—�p�/ 7L�14 QV i N l l4 City Zip Tel. I La 414rat-CA- State Lic. (City & Classif. Vi 3'6 /51 _` Lic. # Arch., Engr., Designer �1VAQAE Address Tel. ),AAma, af✓A Lic. # j LIC S ep RACTOR'S DECLARATION I hereby a um that m s urf provisions of Chapter 9 (commencing with Section 7000 of Di io 3 o t usin Professions Code, and m license is in f�jll forge and effect. Z /.� / OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031 .5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). 0 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). h ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company O Copy is filed with the city. 0 Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CONST. OCC. GRP. A.P. Number T7 " ®% Legal Description '� / P,• �9 ` -4- Project Description e 'I Z ' /- AC j Sq. Ft. No. Size f Stories C New Add ❑ Alter ❑ I Estimated Valuation PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS No. Dw. Units Repair ❑ Demolition ❑ ZONE: BY: Minimum Setback Distances: U FEB Front Setbacl frc Cen Rear Setback rom Rela��iFl Side Street S Side Setback fro:'n Property Lin FINAL DATE INSPECTOR— Issued by: Validated by:— Validation: YELLOW = APPLICANT Date Permit PINK = FINANCE AMOUNT CID Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760') 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/MD. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Residence is at the Hideaway Date: August 2, 2007 Owner's Name: Gary Frana Phone -No. 771-5378 Project Address: 80-260 Via Pessaro La Quinta, CA Project Description: 1 SFD APN: 777-210-013 Tract #: Type of Development: Residential XX Commercial Lot #'s: Industrial Total Square Feet of Building Area: 3,982 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above � o ton is correct and makes this statement under penalty of perjury and further represents that he/she is autho ' ed )o sigq on by • wner/developer. Dated: 8-2-07 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code 65995 3,982-- $3.48 ,982 .$3.48 $13,857.36 Building Permit Application Completed: Yes/No Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement By: Carey M. Carlson, Asst. Supt., Support Services No etet Certificate issued by: Elvira Mattson, Office Technician Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions (f°Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other zpplicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as aerein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts (m the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. MV:c/mydocs/devfees/certificate of compliance form updated =-2007 3/9/07 Hug .21 07 03:59p August 13, 2007 jackie frana Mr. and Mrs. Gary Fraena 53749 Via Pisa La Quinta, CA 92253 775-849-3247 HIDEAWAY OWNERS ASSOCIATION RE: Fmna/Final Design Review 02 Lot 199 at 80260 Via Pessaro Dear Mr. Frana, The Hideaway Design Review Committee met to discuss your Design plans for Lot 199. The plans were approved for conn the following comments are addressed prior to the setback inspt 1. Caesalpinea is shown in the transition area but is not allowed in tha 2. There are symbols used on the landscape plan that are not in the leg -. -3. The minimum requirements for canopy trees has not been met, 5 a shown on your plan. 4. -Five trees are permitted to be uplit, your plan shows 7. 5. Site•details are not to scale and lacking dimensions. 6. The site plan does not have the -material specifications called out. . 7. The location and screening of the electric and gas meters will.need 8. Please specify the driveway materials and concrete texture and col( 9. Please indicate where the guest parking will be and how it will be s 10. Exterior service areas and a/c units are not sh6wn on the plans, i.e. work areas, bbq, heat lamps, misters, etc. Please show this with y hove they will be screened from view. Trash containers must 1 service personnel. 11. Please specify the exterior wall material colors, the wall and fii texture and/or pattern of the stucco. 12. The roof the is called out as concrete tile roof, this is not permitted 13. Do proposed windows contain coated, tinted, reflective or mirrorec 14. The colorboard was approved with comments, only 2 roof tiles w must be a 4 color blend.- Please lend: Please contact Mindy Gutierrez at (760) 393-5211 to schedule meeting. We look forward to working with you further on this proje Sincerely,. . Hideaway. Design Review. Committee. - CC. billQbbearclritegMcom Ray Martin, DRC Sit 80955 Avenue 52 La Quinta, CA 92253 P: 760 391-5072 x210 F: 760 398-5788 submirml of Final to begin provided location. needed: only one is be provided. ened fnm view. sh disposal, outdoor r next submittal and easily accessible to materials and the ;sheet 2.44. glass? re submitted, the roof preconstruction General Load 4000 sq. ft. at 3 VA Three 20 A circuits for small appliances Laundry circuit Pool and spa Two ovens Dishwasher Washer/ Dryer Lamp load Total General Load First 10KVA @ 100% Remainder @ 40% Subtotal General Load A/C Grand Total 12,000 VA 4,500 VA 1,500 VA 2,000 VA 8,000 VA 1,200 VA 5,000 VA 2,000 VA 36,200 VA -10,000 -10,480 15,720 VA 30,840 VA 46,560 VA div. by 240=194 AMP Electric load calcs for lot 199, the Hideaway - a6() J/ARE5�;r-AK p La Quinta Builders Inc. 28 -Aug -07 NO CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED F R NSTRUC ON DA 8 � D �� CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 11/17/2006 Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance)'Packet to the Public Works Department until ALL requirements listed below are. complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date: 4 p 7 Developer: Tract No.: Tract Name: Address(s).: 70--O6n tjid."'�14 The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the Building & Safety Department: ❖ CUSTOM HOMES: PROVIDE ITEMS #2 #3 #4 AND #5 BELOW ❖ TRACT HOMES:. PROVIDE ITEMS #1 #2 #3 #4 (AS/ -APPLICABLE) AND #6 BELOW ❖ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1 #2 #3 AND #5 IVED WALLS: PROVIDE ITEMS #7 BELOW )UN 2i Luu,r ❖ SIGNS: PROVIDE ITEMS #8 BELOW PUBLIC WORKS 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of.+/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months -of current date). If a precise grading plan creates the pad for approval, please. withhold green sheet submittal until a Pad Elevation Certificate can be provided. Attach, geotechnical certification of grading plan compliance. Attach recorded final map showing proposed building locations are legal lots. V,44. Attach a completed < 1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for. commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requ rements. ✓5. Attach an approved precise grading plan for the building location(s). AO flood zone developments will require an approved flood plain development plan. 6. Attach an approved rough grading plan for the building location(s). 7. Attach wall plan & related approved grading plan. 8. Attach sign layout/plan & related precise grading/landscape plan. I have reviewed and confirmed the requirements listed above as presented and finJ the improvements to be sufficiently complete for constructionOay posed buildings/structures/walls/signs on the subject lot(s). Pursuant t Zindings the ab vbe released for building permit issuance. Recommended by: Dated: Public Works Distribution: ( L,,f Green Sheet to Building & Safety counter (_) Green Sheet to Community Development Declined for approval for reason(s) as follow(s), please correct and resubmit: City of La Quinta - PM 10 Project Information (< 1 acre per Lot or Infill Project) Page 'I of 3 Form updated & effective 8/25/2005 Project Information Project Contractor: Project Phase LA �� lArM /G POO Project Phase (Check One): Project r1eA11J 4 41A, -Se ❑ Construction Project Tract Number: • WIWAo lA y ❑ Demolition Lot Number(s): tq� Anticipat d tart Date: g /0 Anticipated Co p etion: Project Street Address: Total ac es in active construction (< 1 acre ! p r Lot) : Aez e e- ) Project Contact Information Please Note: Dust control is required 24 hours a day, 7 days a week, regardless of construction status. Person listed below is responsible for dust control during business and non- siness hours. Name: 6N�GA, �- Title- / Company Name: u iti T _0u IL PMS C� . Mailing Address: I g5- "-- N 6 LO City: LA &u itv State: Zip Code: , Primary Telephone Number: 760- `1 l l- 93-717 Fax:yE 24 Hour Access/Emergency Phone: E Cell Phone: % 6 D - Y'T S - PM 10 Certificate Number: 07-067— q(, g 6 ❖ Expanded PM 10 plans for commercial and residential developments > 1 acre are required by the City of La Quinta. 1 City of La Quinta - Site Specific Construction Phase PM 10 Agreement Page 3 of 3 Agreement updated & effective 8/25/2005 The signature of the property owner (or authorized representative): ❖ Shall act as his/her acknowledgement of dust control requirements End their enforceability, pursuant to AQMD Rules 403 and 403.1; ❖ Shall constitute and agreement to comply with all project conditions as idientified in the approved dust control plan; The property owner (or authorized representative): ❖ Acknowledges that dust control is .required 24 hours a day, 7 days a week,' throughout the period of project performance., regardless of project size or status; ❖ Shall ensure that each and every contractor/subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; ❖ Shall take all necessary precautions to minimize dust, even if additional. measures beyond those listed in the dust control plan are necessary; ❖ . Shall authorize representative of the City/County to enter upon the above mentioned property for inspection and/or abatement purposes; and Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control plan or any City/County initiated abatement activities. Signature of Prop Printed Name Title Company Owner or Apthorized Representative u I Al TA —014 tit r c. paS 1 c. 2-6 ate PM 10 (< 1 acre per Lot or Infill Project) Fugitive Dust Control Plan Page 2 of 3 Plan updated & effective 8/25/2005 This plan shall take into account applicable SCAQMD Rule 403 regulations. Training may be obtained by contacting SCAQMD (Sharon Zamora - Phone: (909) 396-2183). This plan shall consist of the following action items: WATERING: Continuous watering is required to prevent dust and must occur a minimum of 4* times daily. Water shall be applied to dry soils to stop: • Visible dust emissions over 20% opacity • Visible dust emissions that travel over 100 feet. • Water source % hch water meter at front (south) side of pad. ❖ EDUCATION: Responsible. Dust Control Individual and key personnel shall attend SCAQMD PM10 class and obtain PM 10 certificate number prior to construction activity. ❖ WEATHER MONITORING: Wind predictions shall be monitored. ❖ SIGNAGE: Use Coachella Valley Fugitive Dust Control Plan Handbook Construction Site Signage Guidelines. ❖ TRAFFIC: Construction traffic shall not be allowed on the pad, unless absolutely necessary. If vehicles operate on pad, pad shall be kept firm and moist through hose watering or sprinklers. Fugitive Dust shall be prevented by.fencing off site to prevent unauthorized traffic on pad. (15 mph maximum traffic speed). ❖ PARKING: Parking is not allowed on the pad. All vehicles must park on street (at designated areas only). ❖ TRACK OUT: Provide 24 hour street cleaning and track out system as approved by City Public Works Inspector. (No dirt on public or private roads). 'Track out shall be cleaned up within one hour of incident. ❖ DIRT PILES: Dirt piles shall be limited to 50 cubic yards and built per California Building Code grading requirements.' Piles shall be kept moist.or covered with tarp material. Larger dirt piles will require stockpile or grading permit. ❖ FENCING: Provide PM 10 fencing at perimeter of public roads and where applicable. Wood .slat fencing can be installed -at rear of property and return 20 feet on either side if HOA restrictions apply. Block walls can replace. PM 10 fencing during the construction phase. ❖ EQUIPMENT: Extra hoses and sprinklers shall be maintained on site.: ❖ EXCAVATION MEASURES: All areas to be excavated or graded shall be pre -watered. Water shall be applied during excavation or grading operations also. ❖ DUMP TRUCKS: Open top dump trucks to be wet down, moist and tarped prior to leaving site. ❖ INACTIVE SITE: Within 10 days of ceasing of activities, re -vegetate or permanently stabilize as required. CITY OF LA QUINTA PLAN CHECK CORRECTION LIST BBG Architects 20371 Irvine Ave, Suite 120 Santa Ana Heights CA. 92707 June 29, 2007 PLAN CHECK NO. 07-424 (Structural) SECOND CHECK) APPROVED ADDRESS 80-260 Via Pessaro OCCUPANCY R -3/U-1 SCOPE OF WORK NSFR TYPE -OF -CONST. V -N The submitted plans and specifications have been reviewed by the VCA CODE GROUP. In our professional opinion the plans are in substantial conformance with the building codes and regulations adopted by the CITY OF LA QUINTA and the State of California Amendment. APPROVAL FOR A BUILDING PERMIT IS HEREBY RECOMMENDED SUBJEC T TO OBTAINING APPROVALS/CLEARANCES FROM ALL APPLICABLE CITY DEPARTMENTS, AGENCIES, AND ASSOCIATIONS. Plans checked by: Sid Danandeh, PE VCA CODE GROUP 2200 W Orangewood Ave, Ste 155 Orange, CA 92868 (714) 363-4700 1 VCA File No. LQ -19442 Certificate of Occupancy -4 a&rcv C� OF TBuilding & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 80-260 VIA PESSARO Use classification: SINGLE FAMILY DWELLING Building Permit No.: 07-424 Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL Owner of Building: GARY FRANA Address: 80-260 VIA PESSARO City, ST, ZIP: LA QUINTA, CA 92253 By: AJ ORTEGA Date: JULY 15, 2008 Building Official POST IN A CONSPICUOUS PLACE A JUL-01-2008 02:20 PM P.02 ZM ttATER CgioWd IJMCZ STATEMERr im�twe w►as: 0' O AWwod Y pert of =mot teatime. but wm not tamed As to !IFAS mor diapat�ic tesbitlS lEsld I.�y est dw Mme idaed wen this tam oen'plio with the diagaattie requteealeats a fan '!'tie iaAi3 cant tesot ehaait snd dst dm new diddbutiae.yam is WI ducted sed c reotUpe is aaei s pm bo tekaied as eMsy bd llte itQAS cstet Qqi� sot ratetoe t!a CT�IR aatif a peapaty eo�IMN alld sifseed Q�6if !moi baeu received far �saa�t hexed inooalter tss Provided a coder dCF�6A pmattYfioti CwtWiaab - wry dntx� are Att�y dutoed B.s, dowi awtitW baifiiy atrWras a pialllsm !arena is ties d duw). New dodr �rilh trot!! baetoa� retb6ar aAretriw door tape insle e�aate set iatw !Wads tuv Red in combination wridt � eio� necked„ enbbsr adneetvr dottapa b sa< lab at dtlot aoastedaoak � j MVfl UM RZQiARMII MS VM WCT LZAZAGS BUMCr= CDMMIM= CUIDIP Procedsim for ttetd vstit�ionattd diap�oatictesd dais diltcmitdog aI Now sma liMb is iarilC4.9. Duct bimmandc Leakom Testitis Rod% a Joe vl Pit V/ pis NZW CONRI'NUCTMNt Duet Praaurisstiae Tot Faolb (Cllr!! ® 25 PM) vw�tass� : �.•i ^',` : �: 1 Enw Tv#W I.adaRe Flair is CFM: : Z F.atrr Tat.! Fan vi('FM. O Cooliq Q or 3 Psu ifLmkap peroent:p c fi% 1100: N 1) d 2)]] ✓ O Fail ALTMAIRM Dad ftee odJee HVAC Mt 4 star Teabd I.wattap Plow ie C4t11f loam CF-tL lrs•Tiet d Dart Systate Phot to Dnct Syuam Altaradm wAObr Bquipaeat Chug& Out , _ . = t :e s s Rola Tuftd I a"M Rowe in CFM Ybd Tat d1Ww► Duct 3AbxW tdrbaetsISM" _A ti RaW RedoWes in Leakap for AnandDuos Bid= L__.i.n• 4) (Only ifADPIim o) _ y >e. uq Toted Lwsinp Flaw is ClM % Otjg& (Ooh► it ) ✓ ✓ Fata+t Naw Drat System • Pars if Lwlsp Psreenlrp < tPK a 100 x N/ Line N1/7 ?i5 1 OR VERDCATM BTANDAYM& !wr Abwed Drat atW 11VAfflTmw Mp4o Oct wee of tkt titer Test w Vwlftesdas S+oosdank hr O Pro O Fad ✓ ./ 9 >'ass if Leaiutge Pbt oettgga c 1591 [100 x `_____(Lina N J ]] O Fars O Faq 10 7)/ (Line N 2)j] D Pars O Fail 11 Pass if IA&P n ft0ft lnSe >60li [100 x L, (Lina x 6) J.,Y.... (UM S 4)n twd Vai4i SumSmoke leu aad VWW O Pw Cl Fail Pamir of all bte Lesks mw xm&,mtian Sntoke Tastand V' : = k: O Pim O Fail _ _ -- Pw r;l Ota ortso N! ehrongL N >Z ecce -' :, ':; _ :�y O Pass O Fait P',Z.- y�f —,[.div " . 7 0 y. !�/ •'1 9�v asotJr bw 2005 41 JUL-01-2008 02:21 PM P.03 HERS RAM 4;9MM NCE STATEMENT 'the hone vim ✓ Twtd ✓ D App vved as prt of ample WWW but was not tawd As Ow HM carat prow ft &qpm io tw+t and 8dd wiiodiog I an* tbst the hoore identified an this tam wnphat with the ostic tossed complFace requkawft a ahG&W on tbu hrim ✓ The imt Uw ha provided is cow of CF -M (Iestallation CsrOcate). ✓ l3t>I1TiffiiitA a cnAR6E Verification for a tar Sok gvstwn Swom Coohm Svmfuw vrithou 7h bion Valves Outdoor Unit serial 0 Lontion Outdoor Utdt Melte Outdoor Unit Model COOKCapacity tttlltr OM of Vwiliaatian Date of !!tfiLwwt clause CAbratiou (mast be checked monddy) Date of Tbwmoca:pto Calfrstiom (mast be ehedted montbly) 9mndsrd Cluwe /autdaQ mi, da -b % 55 2 and abM Note: Ma systan should be intalled and cbarsed in accordance with the shall be documaaod on CA -a before sta ug this proudm If outdoor Chrome Meuare Prooedare ✓ Q Yes D No r sler v�catiat i• SS I use the Alternative Raidendd Canphiovrce Forms Apri12005 Amm is pruvidedEat irspeatioa. The pnmdm thea consist of ✓ es D No viwrai vw&m i+m slut rho TXV is bmaN d an tie system mW O installation olthe aball bevadAad. Ya is a Fm Fail ✓ l3t>I1TiffiiitA a cnAR6E Verification for a tar Sok gvstwn Swom Coohm Svmfuw vrithou 7h bion Valves Outdoor Unit serial 0 Lontion Outdoor Utdt Melte Outdoor Unit Model COOKCapacity tttlltr OM of Vwiliaatian Date of !!tfiLwwt clause CAbratiou (mast be checked monddy) Date of Tbwmoca:pto Calfrstiom (mast be ehedted montbly) 9mndsrd Cluwe /autdaQ mi, da -b % 55 2 and abM Note: Ma systan should be intalled and cbarsed in accordance with the shall be documaaod on CA -a before sta ug this proudm If outdoor Chrome Meuare Prooedare ✓ Q Yes D No r sler v�catiat i• SS I use the Alternative Raidendd Canphiovrce Forms Apri12005 r' ..: TITLE 24 REPORT Title 24 Report for: Frana Residence Lot 199 -Hideaway La Quinta, CA 92253 Project Designer: BBG Architects 20371 Irvine Avenue, Suite 120 Santa Ana Heights, Ca 92707-5651 (714) 434-2506 ' Report Prepared By: Tim Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA &12 BY Job Number: Date: 7/20/2007 he EnergyPro computer program has been used to perform the calculations summarized in this compliance report_ This program has approval and is uthorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. I" EnergyPro 4.3 by EnergySoft Job Number: User Number: 6712 I ., TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 8 Form WS -5R Residential Kitchen Lighting 10 HVAC System Heating and Cooling Loads Summary 11 Room Load Summary 14 Room Heating Peak Loads 17 Room Cooling Peak Loads 21 EnergyPro 4.3 by EnergySoft Job Number: User Number: 6712 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R Percent better Building Type: W Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (SE) 150 deg Natural Gas Area: 654 ft2 Avg. U: 0.58 Ratio: 16.4% Avg. SHGC: 0.46 8.5% Total Conditioned Floor Area-. 3,982 ft2 Existing Floor Area: 7/20/2007 oject Title Raised Floor Area: 0 ft2 Date 3,575 ft2 Average Ceiling Height: 10.9 ft Project Address 1.00 Number of Stories: Building Permit # Scott Design & Title 24 (760) 200-4780 Documentation Author Telephone Plan Check/Date EneWVPra Compli-arice Method 15 Climate Zone Field Cieck/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.51 2.88 -0.37 Space Cooling 60.95 54.58 6.37 Fans 8.66 9.24 -0.58 Domestic Hot Water 6.07 4.87 1.20 Pumps 0.00 0.00 0.00 Totals 78.19 71.57 6.62 Percent better Building Type: W Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (SE) 150 deg Natural Gas Area: 654 ft2 Avg. U: 0.58 Ratio: 16.4% Avg. SHGC: 0.46 8.5% Total Conditioned Floor Area-. 3,982 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 3,575 ft2 Average Ceiling Height: 10.9 ft Number of Dwelling Units: 1.00 Number of Stories: 2 BUILDING ZONE INFORMATION # of Thermostat oone Name Floor Area Volume Units Zone Type Type HVAC -1 685 6 987987 _D 17 Concifioned Setback HVAC -2 8. 3 2 908 2,594 0 73 Conditioned 5:ethark HVAC -4 389 3,890 0.10 Conditioned S-etback OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rnnf Wnnd 685 n n25 R_38 R-0 0 180 _n Wall Wood 209 0.069 R_21 R-0.0 240 gp Wall Wood 203 0069 R-21 R-0.0 340 go Wall Wnnd d66 n n69 R_91 R_n n sn gn Wall Wood 160 0.069 R-21 R-0.0 150 gn Roof Wood 2,094 n 095 R_38 R-0 0 180 Wall Wnnd 527 n n69 R-21 R_0 n Zan _gIl Wall Wnnd 433 n 069 R_91 R -n n 330 gn Wall Wood 242 0 069 R_21 R-0 0 60 go Wall Wood 630 n 069 R-21 R-0 0 150 q.Q nonr Nnne 28 _0 `00 NnnP R -n n 15n q0 r)nnr Nnne 24 n 5nn NnnP R_n n 150 q0 Roof Wood 407 002,15 R_38 R-0 0 180 0 Wall Wood 204 n 0SP R-21 R-0.0 240 90 Wall Wood 112 0.069 R_21 R-0.0 330 _gQ Wall Wood 197 0069 R-21 R-0 0 so gn Wall Wnnd 156 n nF;9 821 R-0 0 150 _g0 Roof Wnnd 389 n 025 R_38 R-0 0 180 0 Wall Wnnd 277 n n6g R_21 R_0 0 24n 90 Wall Wood 120 0 069 R-21 R-0.0 330 qn Wall Wnnd 294 0 069 _$_21 R-0.0 6Q 90 Wall Wood 154 0 069 R-21 R-0.0 150 90 Vent Hgt. Area B n/a n/a 8 _n/ Gains Condition Y / N Status JA IV Reference Location / Comments EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Pape:3 of 24 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Title 7/20/2007 Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments .!< Window Rear (NW) 72 0 0_580 116_A -0-46 -2-- Window Right (NE) 2.3 0.580 116-A 0.46 -3' Window Right (NE) 2.3 0.580 116-A 0_46 4- Window Right (NE) 2.3 0.580 116-A 0_46 o5o� Window Right (NE) 6.0 0.580 116-A 0_46 +6' Window Right (NE) 13.8 0.580 116-A 0_46 ,T-- Window Right _(NE) NFRC: 60 90 New Double Non Metal Tint 13.$ 0.58 116-A 0_46 .S- Window Right (NE) 6.0 0.580 116-A 0.46 Window Left (,SW) 10.0 0_580 116-A 0_46 !TT Window Left (SW) 8.8 0_580 116-A 0_46 fT Window Left SW 7.0 0_580 116-A 0_46 Window Left (SW) 7.0 0.580 116-A 0_46 Window Left (SW) 7.0 0_580 116-A 0_46 -W Window Left (SW) 11.3 0.580 116-A 0_46 Window Rear (NW) 96.0 0.580 116-A 0.46 4A- Window Rear NW 135.0 0.580 116-A 0.46 _Window Right (NE) 18.0 0.580 116-A 0_46 PWS Window Front (SE) 40.0 0.580 116-A 0.46 -jr Window Front (SE) 12.5 0_580 116-A 0_46 NERC -330_ _90- New Double Non Metal Tint Master Ste NFRC 60 90 New Double Non Metal Tint Master Ste NFRC 60 90 New Double Non Metal Tint Master Ste NFRC 60 90 New Double Non Metal Tint Master Ste NFRC 60 90 New Double Non Metal Tint Master Ste NFRC 60 90 New Double Non Metal Tint Master Ste NFRC 60_ 90 New Double Non Metal Tint Master Ste NFRC 60 90 New Double Non Metal Tint Master Ste NFRC 240 90 New Double Non Metal Tint Living/Den/Kit/Nook/Din NFRC -244_ 90 New Double Non Metal Tint Living/Den/Kit/Nook/Din NFRC 240 90 New Double Non Metal Tint Living/Den/Kit/Nook/Din NFRC 240 90 New Double Non Metal Tint Living/Den/Kit/Nook/Din NFRC 240 --Q New Double Non Metal Tint ivi g/Den/Kit/Nook/Din NFRC 240 90 New Double Non Metal Tint Living/Den/Kit/Nook/Din NFRC 330 90 New Double Non Metal Tint Living/Den/Kit/Nook/Din NFRC 330 90 New Double Non Metal Tint Living/Den/Kit/Nook/Din NFRC: 60 90 New Double Non Metal Tint Living/Den/Kit/Nook/Din NFRC 150 90 New Double Non Metal Tint Living/Den/Kit/Nook/Din NFRC 150 90 New Double Non Metal Tint Living/Den/Kit/Nook/Din 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REM. Dist. Len. Hgt. Dist. Len. Hgt. 1 Buo Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 Type Bug Screen 0.76 (in.) Cap. Cond. R -Val. Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Buq Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Paoe:4 of 24 1 Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight 428 3.50 28 0_98 2 26-A1 New feaster Ste / Slab on Grade Concrete, Heavyweight 257 3.50 28 0_98 0 26-A1 New N aster Ste / Slab on Grade Concrete, Heavyweight 391 3.50 28 0_98 2 26-A1 New Lvin /Den/Kit/Nook/Din / Slab on Concrete, Heavyweight 2,110 3.50 28 0_98 0 26-A1 New /Den/Kit/Nook/Din /Slab on Concrete, Heavyweight 311 3.50 28 0_98 2 26-A1 New 112 / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 86 None No Insulation 26-A1 New Master Ste Slab Perimeter 25 None No Insulation 26-A1 New Master Ste lab Perimeter 63 None No Insulation 26-A1 New Living/Den/Kit/Nook/Din Wb Perimeter 97 None No Insulation 26-A1 New Living/Den/Kit/Nook/Din Iffab Perimeter 75 None No Insulation 26-A1 New Casita EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Paoe:4 of 24 1 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R 7/20/2007 Date True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments Window Left (SW 1 50058 580 116-A 04 NFRC 740 q0_ New Double Non Metal Tint _Second Floor f21- Window Left (SW) 5.0 0.580 116-A 0.46 NFRC 240 90 New Double Non Metal Tint Second Floor Window Left (SW) 5.0 0.580 116-A 0_46 NFRC 240 90 New Double Non Metal Tint Second Floor "Q3r Window Rear (NW) 9.0 0.580 116-A 0.46 NFRC 330 90 New Double Non Metal Tint Second Floor 4''Window Rear (NW) 35.0 0.580 116-A 0_46 NFRC 330 90 New Double Non Metal Tint Second Floor - Window Rear (NW) 9.0 0.580 116-A 0_46 NFRC 330 90 New Double Non Metal Tint Second Floor Window Front (,SE) 5.0 0.580 116-A 0_46 NFRC 150 90 New Double Non Metal Tint Second Floor ,QT- Window Front (SE) 5.0 0.580 116-A 0.46 NFRC 150 90 New Double Non Metal Tint Second Floor Window Front (SE) 5.0 0_580 116-A 0_46 NFRC 150 90 New Double Non Metal Tint Second Floor oiff Window Left (SW) 3.8 0.58011&$ 0.46 _ NFRC 240 90 New Double Non Metal Tint Casita Window Left (SW) 24.0 0.580 116-A 0_46 NFRC 240 90 New Double Non Metal Tint Casita .a9' Window Left SW 10.0 0.580 116-A 0_46 NFRC 240 90 New Double Non Metal Tint Casita Window Rear (IOW) 40.0 0.580 116-A J146 NFRC 330 _QQ New Double Non Metal Tint Casita .a3" Window Right (NE) 10.0 0.580 116-A 0_46 NFRC 60 90 New Double Non Metal Tint Casita :_Window Right (NE) 6.0 0.580 116-A 0.46 NFRC 60 90 New Double Non Metal Tint Casita IVindow Front (SE) 6.0 0.580 116-A 0_46 NFRC 150 90 New Double Non Metal Tint Casita 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fir Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight 78 3.50 28 0_98 0 26-A1 New Casita / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 19 None No Insulation 26-A1 New Casita Run Initiation Time: 07/20/07 13:44:01 Run Code: 1184964241 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:5 of 24 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R _Erana Residence 7/20/2007 111111111111111111111111loiect Title Date 'AC SYSTEMS Location Heating Type Minimum Eff Cooling Type Minimum Eff Condition Status Thermostat Type HVAC -1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC -2 & 3 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC -4 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback -HVAC DISTRIBUTION WATER HEATING SYSTEMS Rated Tank Energy Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC -1 Ducted Ducted Attic 4.2 New Yes HVAC -2 & 3 Ducted Ducted Attic 4.2 New Yes HVAC -4 Ducted Ducted Outdoors 4.2 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Rheem HE119-160 Large Gas All Pipes Ins 1 160,000 119 New 0.87 0.85% 0.0 Multi -Family Central Water Heating Details Hot Water Pump Control # HP Type Hot Water Piping Length (ft) Add 1/2" In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: BBG Architects Address: 20371 Irvine Avenue, Suite 120 Santa Ana Heights, Ca 92707-5651 Telephone: (714) 434-2506 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: ignature) (date) Documentation Author Name: Tim Scott Title/Firm: Scott Design & Title 24 Address: 77085 Michigan Dr. Palm Ddsert. CA 9P211 Telephone: 7 0-4780 77 (signature) d e) 1 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Paoe:6 of 24 1 4 4 Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Title 7/20/2007 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field HIGH MASS Design - Verify Thermal Mass: 428 sqft Covered Slab Floor, 3.50" thick at Master Ste HIGH MASS Design - Verify Thermal Mass: 257 sqft Exposed Slab Floor, 3.50" thick at Master Ste HIGH MASS Design - Verify Thermal Mass: 391 sqft Covered Slab Floor, 3.50" thick at Living/Den/kit/Nook/Din HIGH MASS Design - Verify Thermal Mass: 2110 sqft Exposed Slab Floor, 3.50" thick at Living/Den/kit/Nook/Din HIGH MASS Design - Verify Thermal Mass: 311 sqft Covered Slab Floor, 3.50" thick at Casita HIGH MASS Design - Verify Thermal Mass: 78 sgft Exposed Slab Floor, 3.50" thick at Casita The HVAC System "HVAC -2 & 3" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF - 4R. The HVAC System "HVAC -2 & 3" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Carrier 38TXA060/58CVX110" includes credit for a 11.6 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "HVAC -4" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC -4" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- OPPIUVCU n�MQ PIUVluer u,111tj l+C\. CIPPFUVeU RMLIF19 dr1U/Ur Vermcation meinoo5 ano must oe reported on the CF -4K installation certificate. plan Field he HVAC System "HVAC -1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. he HVAC System "HVAC -1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. IT he Cooling System "Carrier 38TXA0363/58CVX070" includes credit for a 11.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "HVAC -2 & 3" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF - 4R. The HVAC System "HVAC -2 & 3" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Carrier 38TXA060/58CVX110" includes credit for a 11.6 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "HVAC -4" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC -4" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Cattire 38TXA024/58CVX070" includes credit for a 12.1 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Pape:7 of 24 1 • 40 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (*) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑ 1XI e§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ Q ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ 0 ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox b. outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed. § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/ExFltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine Imes), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ ❑ o ❑ ❑ a ❑ ❑ 1XI ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ IR ❑ ❑ 0 ❑ ❑ ER ❑ ❑ a ❑ ❑ a ❑ ❑ a ❑ ❑ a ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ IEnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:8 of 24 ►. Mandatory Measures Summarv: Residential (Page 2 of 2) MF -1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated • into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. is • DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requiremerts of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ reductions in the cross-sectional area of the ducts. § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ ❑ luminaire has factory installed HID ballast. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑ ❑ 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ retardant and provides shielding from solar radiation that can cause degradation of the material. 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑ ❑ controlled by an occupant sensor that complies with Section ll 19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:9 of 24 I& Residential Kitchen Lighting Worksheet WS -5R 7/20/2007 Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts 1 26w Compact Fluorescent Triple 4 Pin Yes X1 No 1 1 28.0 x 14 = 392 or 04 ft Fluorescent T8 Energy Savings Elec Yes X1 No 1 29.0 x 4 = 116 or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No I x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or • Total A: 508 B: 0 COMPLIES IF Az B YES ® NO ❑ EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Paae:10 of 24 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Frana Residence 7/20/2007 STEM NAME FLOOR AREA HVAC -1 685 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 75 12,820 1,559 326 13,323 0 1,341 1,015 0 0 0 0 0 0 0 0 0 1,341 1,015 15 502 1 559 Carrier 38TXA0363/58CVX070 23,169 8,808 Total Adjusted System Output 3,169 8,808 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK i Aug 2 pm 1573531 51,000 51,000 Jan 12 am HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatina Peak) I 26.0 OF Outside Air 0 cfm 69.2 OF 69.2 OF ® 109.10F Heating Coil 109.1 °F O Supply Air Ducts Supply Fan 108.3 OF 1200 cfm ROOMS 70.0 OF Return Air Ducts I (COOLING SYSTEM PSYCHROMETRICS (Airstream Temoeratures at Time of Coolina Peak) 1 11.0 / 77.6 OF Outside Air 0 cfm 79.1/66.3 °F 79.1 / 66.4 OF M 60.9 / 59.9 OF Cooling Coil rM Supply Fan 1200 cfm 60.9 / 59.9 of -�j Supply Air Ducts 62.0/60 . 2 of 53.5% R.H. ROOMS 78.0 / 66.0 OF h Return Air Ducts 4 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Paae:11 of 24 1 ". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Frana Residence 7/20/2007 STEM NAME FLOOR AREA HVAC -2 & 3 2 cm ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 2 COIL COOLING PEAK COIL HTG. PEAK Heating Svstem I CFM I Sensible Latent CFM I Sensible Output per System Total Output (Btuh) Output (Btuh/sgft) Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfm/sqft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRI 26.0 OF 69 Outside Air 0 cfm 69.3 of 89,000 178,000 2,295 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 61.2 39,756 59,000 118,000 9.8 40.6 295.7 2,295 40,682 4,822 925 39,756 0 4,255 3,029 0 0 0 0 0 0 0 0 0 4,255 1 3,029 49,192 4,822 45 814 2,000 4,000 Carrier 38TXA060/58CVX110 79,414 27,712 178,000 1.38 406.8 o.o Total Adjusted System Output 79,a1a 27,712 178,000 am (Adjusted for Peak Design Conditions) 0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 .3°F ® 111.1°F Heating Coil ratures at Time of Heating Peak) 111.1°F O Supply Air Ducts Supply Fan 110.4 OF 4000 cfm ROOMS 70.0 OF �% Return Air Ducts 4 (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) 111.0 / 77.6 OF Outside Air 0 cfm 79.0/65.9 °F 79.0 / 66.0 °F M 60.3/59.30F Cooling Coil Supply Fa 4000 cfm 60.3 / 59.3 of Supply Air Ducts Fan 61.3/59.6OF 52.3% R.H. ROOMS 78.0 / 65.6 OF h Return Air Ducts 4 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:12 of 24 1 a' HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Frana Residence 7/20/2007 STEM NAME FLOOR AREA HVAC -4 389 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 51 10,117 1,23 164 10,152 0 1,058 774 0 0 0 0 0 0 0 0 0 1,058 1 774 12 233 1 23 11 699 Cattire 38TXA024/58CVX070 17,941 4,349 51,000 Total Adjusted System Output17,841 4,349 51,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.1 OF 69.1 OF 129.0 OF Outside Air O S-jpply Air Ducts 0 cfm 128.1 of Supply Fan Heating Coil 800 cfm ROOMS 69.1 of 70.0 of Return Air Ducts I COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6 OF 79.2/64.9 OF 79.2/64.9 OF 58.2/57.0 OF O SLpply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 59.4 / 57.5 of 800 cfm 48.3% R.H. ROOMS 79.2/64.9 of 78.0 / 64.4 of h Return Air Ducts 14 I EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Paoe:13 of 24 1 ROOM LOAD SUMMARY PROJECT NAME Frana Residence DATE 7/20/2007 STEM NAME HVAC -1 FLOOR AREA 685 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Master Ste Master Ste 1 751 12,820 1,559 751 12,820 1,559 326 13,323 PAGE TOTAL 751 12,820 1,559 326 13,323 TOTAL 1 751 12,820 1,559 326 13,323 EnergyPro By EnergySoft User Number: User Job Number: Page: 14 of 24 k, ROOM LOAD SUMMARY 71 PROJECT NAME DATE Frana Residence 7/20/2007 STEM NAME FLOOR AREA HVAC -2 & 3 2,908 ROAM COOI Mr. PFOK I COII COOT mr.,PFAK II COn HTf; PEAK aecono rioor Second Floor 1 1 11 5061 8,9741 1,2511 5061 8,9741 1,25111 1461 6 PAGE TOTAL 1 2,295 40,68214,822 925 39,756 TOTAL 1 2,295 40,68214,82211 925 39,756 EnergyPro By EnergySoft User Number: User Job Number: Page: 15 of 24 ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM I SENSIBLE Living/Den/kit/Nook/DinLiving/Den/KiUNook/Din 1 1,789 31,707 3,571 1,789 31,707: 3,571 779 33,477 aecono rioor Second Floor 1 1 11 5061 8,9741 1,2511 5061 8,9741 1,25111 1461 6 PAGE TOTAL 1 2,295 40,68214,822 925 39,756 TOTAL 1 2,295 40,68214,82211 925 39,756 EnergyPro By EnergySoft User Number: User Job Number: Page: 15 of 24 L/_ ROOM LOAD SUMMARY PROJECT NAME Frana Residence DATE 7/20/2007 STEM NAME 47 HVAC -4 FLOOR AREA 389 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Casita Casita 1 511 10,117 1,231 511 10,117 1,231 164 10,152 PAGE TOTAL 1 511 10,117 1,231 164 10,152 TOTAL 1 511 10,117 1,231 164 10,152 EnergyPro By EnergySoft User Number: User Job Number: Page: 16 of 24 1 ROOM HEATING PEAK LOADS Project Title rana Residence 17/20/2007 Date oom Information Desi n Conditions Room Name Master Ste Floor Area 685 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 12 am Outdoor Dry Bulb Temperature 26OF Conduction Area X x X x X X x x X x x X x x X X X x x x X X X x X X X X X x X x x X X X X X X U -Value X X x x x x X x X X x x x x X x x X x x X x X X x X x x X x x x x X X x x x x pT of = = = = = = = = = = = = = = = = = = = = = Btu/hr R-38 Roof Attic 685.0 0.0250 44 754 R-21 Wall 209.0 0.0690 44 635 R-21 Wall 203.0 0.0690 44 616 Double Non Metal Tint 72.0 0.5800 44 1,837 465.5 0.0690 44 1,413 Double Non Metal Tint 2.3 0.5800 44 59 Double Non Metal T'nt 2.3 0.5800 44 59 Double Non Metal Tint 2.3 0.5800 44 59 Dniffilp Nrin Metal Mitt 6.0 0,5800 44 153 Double Non Metal Tint 13.8 0.5800 44 352 Dnuhla Non Metal Tnt 13.8 0.5800 44= Double Non Metal Tint 6.0 0.5800 44 153 R-21 Wall 160.0 0.0690 44 486 Slab -On -Grade Derimeter = 86.0 0.7300 44= 2,762 .ql.qh-On-Gr:;rip perimeter = 25.0 0.7300 44= items snown witn an astensK (f-) aenote conoucuon tnrougn an interior surtace to anotner room. Page Total: 10,493 Infiltration: I 1.001X 1.064 x 685 x 10.20 x 0.519 / 60] x 0 = 2 830 chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 13,323 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 17 of 24 ,► ROOM HEATING PEAK LOADS Project Title Date a a Residence 7/20/2007 oom Information Desi n Conditions Room Name Time of Peak Jan 12 am Floor Area 2,501 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value LT of Btu/hr IDouble Non Metal Tint I 2,094.0 X x X X X X X X X X X X X X x x X X x X X X x x X X x X X X X X X X X X x X X 0.0250 X X X X X x X X X X x x x x x x X X x X x X X x x X x X X x x X X X X X x X X 44 = = = = = = = = = = = = = = = = = = 2,303 526.9 0.0690 44 1,600 10.0 0.5800 44 255 8.8 0.5800 44 225 7.0 0.5800 44 179 7.0 0.5800 44 179 7.0 0.5800 44 179 11.3 0.5800 44 288 433.0 0,0690 44 1.315 96.0 0.5800 44 2,450 135.0 0.5800 44c3 445 242.0 0.0690 44 735 18.0 0.5800 44 459 629.5 0.0690 44= 1,911 28.0 0.5000 44=616 24.0 0.5000 44 528 400 0,5800 44= 12.5 0.5800 44=319 perimeter = 63.0 0.7300 44 2,024 perimeter = 97.0 0.7300 44 3,116 I nems shown with an astensK (-rr) denote conduction through an interior surface to another room. Infiltration: I 1.00 x 1.064 x 2 501 x 11.60 x 0.456 / 60] x Page Total: 0 = I 23.145 10 332 chedule Air Sensible Area Ceiling Height ACH Fraction &T TOTAL HOURLY HEAT LOSS FOR ROOM EnergyPro 4.3 by Energysoft User Number: 6712 Job Number: Page: 18 of 24 L 1 1) ROOM HEATING PEAK LOADS EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 19 of 24 Project Title Date rana Residence 17/20/2007 Room Information Desi n Conditions Room Name Second Floor Floor Area 407 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 12 am Outdoor Dry Bulb Temperature 26OF Conduction surface Area Area X X x x X x X x X x x X X x X X X X X X x X x x X X X X X X X X X X X X X X X s.so x U -Value X X X x X X x x X X X X x x X X x X X X X X X x X X X x x X X X X X X X X X X x AT of = = = = = = = = = = = = = = = = = = = = = = = Btu/hr R-38 Roof Attic 407.0 0.0250 44 448 R-21 Wall 204.0 0.0690 44 619 Double Non Metal Tint 5.0 0.5800 44 128 Double Non Metal Tint 5.0 0.5800 44 128 Dnuble Non Metal Tint 5.0 0.5800 44 128 R-21 Wall 112.0 0.0690 44 340 Double Non Metal Tnt 9.0 0.5800 44 230 Double Non Metal Tint 35.0 0.5800 44 893 nniffilp Nnn Metal Tint 9.0 0,5800 44 230 R-21 Wall 197.0 0.0690 44 598 R-91 Wall 156.0 0.0690 44=474 Double Non Metal Tint 5.0 0.5800 44 128 Double Non Metal Tint 5.0 0.5800 44 128 Double Non Metal Tint 5.0 0.5800 44= 128 Items shown with an asterisk (') denote conduction through an interior Infiltration: r 1.001 x 1.osa x `schedule Air Sensible Fraction to another room. ao7 x Ceiling Height 0.802 / 60] ACH Page Total: DT 4 597 1 681 TOTAL HOURLY HEAT LOSS FOR ROOM 6,278 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 19 of 24 1 1� ROOM HEATING PEAK LOADS Project Title Date rang Residence 17/20/2007 room Information Desicin Conditions Room Name Casita Time of Peak Jan 12 am Floor Area 389 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value QT of Btu/hr IDouble Non Metal Tint I 389.0 X X X x X X x X X x x x X x X X X X X X X X X x X X X X x X x X X X x X X x x 0.0250 X x x X X X X X X X x X X x X x x X X x X x X x x x x x x x x x x x x x x x X 44 = = = = = = = = = = = = = = = = = = = = 428 272.2 0.0690 44 826 3.8 0.5800 44 97 24.0 0.5800 44 612 10.0 0.5800 44 255 120.0 0.0690 44 364 40.0 0.5800 44 1,021 294.0 0.0690 44 893 0,5800 44 255 6.0 0.5800 44 153 154.0 0.0690 44=488 6.0 0.5800 44 153 perimeter = 75.0 0.7300 44 2,409 perimeter = 19.0 0.7300 44= 610 Items shown with an astensK (`r) denote Conduction through an Interior surface to another room. image Total: I 8,5451 Infiltration: 1 1.001 x 1.064 x 389 x 10.00 x 0.529 / 6] x 44 = 1 607 chedule Air Sensible Area Ceiling Height ACH GT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 10,152 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 20 of 24 t v • RESIDENTIAL ROOM COOLING LOAD SUMMARY PLranta::R:Ee-sidence Date 7/20/2007 oom Information Desicin Conditions Room Name: Master Ste Outdoor Dry Bulb Temperature: 1120F Floor Area: 685 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F • Lie surraces R-21 Wall Orientation Area X X X X X X X X X X x X U -Factor X X X X X X x X X X X X CLTD 1 = = = = = = = S 685.0 0.0250 56.0 SW 209.0 0.0690 31.7 NW 203.0 0.0690 29.3 NE 465.5 0.0690 30.3 SE 160.0 0.0690 29.3 28.7+ 2.3X 47.6= NE 0.0X 28.7+ 6.0X 47.6= NE 0.0x 28.7+ 13.8X 47.6= NE 0.0x 28.7+ 13.8X 47.6= NE 0.0x 28.7+ 6.0X 47.6= Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window rage I otai Orientation Shaded Area X x X+:::::�] X GLF + + Unshaded Area x x X x Page GLF = = = NW 0.0 28.7 72.0 38.5 NE 0.0x 28.7+ 2.3X 47.6= NE 0.0x 28.7+ 2.3X 47.6= NE 0.0x 28.7+ 2.3X 47.6= NE 0.0X 28.7+ 6.0X 47.6= NE 0.0x 28.7+ 13.8X 47.6= NE 0.0x 28.7+ 13.8X 47.6= NE 0.0x 28.7+ 6.0X 47.6= F+ Total Btu/hr 959 457 411 974 324 3 124 Btu/hr Internal Gain Btu/hr Occupants E 4 X Occupants X 230 Btuh/oCC. = 920 ui ment 1 X Dwelling Units X 1,6001 Watts/sqft = 1 600 Infiltration: 1.064 X 1.39 X 43.40 X = 2187 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12 820 Latent Gain Btu/hr Occu ants ® X Occupants x 1 200 Btuh/oCC. = 800 Infiltration: 4 771 x 1.39 x 43.40 x 0.00263 = 759 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,559 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:21 of 24 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date ana aResidence 7/20/2007 Dom Information Desicin Conditions Room Name: Living/Den/kit/Nook/Din Outdoor Dry Bulb Temperature: 1120F Floor Area: 2,501 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F opaque surtaces R-38 Roof Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall Wood Door Wood Door Orientation Area x X X X X X X x X X X X U -Factor X X X X X X x x X X X X CLTD 1 = = = = = = = = = = = S 2,094.0 0.0250 56.0 SW 526.9 0.0690 31.7 NW 433.0 0.0690 29.3 NE 242.0 0.0690 30.3 SE 629.5 0.0690 29.3 SE 28.0 0.5000 29.3 (SE) 24.0 0.5000 29.3 SW 0.0x 28.7+ 11.3X 40.4= NW 0.0x 28.7+ 96.0X 38.5= NW 0.0x 28.7+ 135.0X 38.5= NE 0.0x 28.7+18.0X 47. Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Window Internal Gain Occupants E 4 ui ment 1 rage I Dial Orientation Shaded Area x X GLF + + Unshaded Area x X Page GLF _ SW 0.0x 28.7+ 10.0x 40.4= SW 0.0x 28.7+ 8.8X 40.4= SW 0.0x 28.7+ 7.0X 40.4= SW 0.0x 28.7+ 7.0X 40.4= SW 0.0X 28.7+ 7.0X 40.4= SW 0.0x 28.7+ 11.3X 40.4= NW 0.0x 28.7+ 96.0X 38.5= NW 0.0x 28.7+ 135.0X 38.5= NE 0.0x 28.7+18.0X 47. SE 00 28.7 40.O Total Btu/hr 2,932 1,151 876 507 1,274 411 352 7,5021 Btu/hr Btu/hr X Occupants X 230 Btuh/occ. = 920 X Dwelling Units X 1,6001 Watts/sqft = 1 600 Infiltration: 1.064 X 1.39 X 158.46 x = 7,984 Air Sensible CFM ELA Z�,T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 31,7071 Latent Gain Btu/hr Occu ants ® X Occupants X 200 Btuh/occ. = 800 Infiltration: 4 771 X 1.39 X 158.46 X 0.00263 = 2-77 Air Latent CFM ELA pW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,571 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 22 of 24 T) RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date rana Residence 7/20/2007 oom Information Design Conditions Room Name: Second Floor Outdoor Dry Bulb Temperature: 1120F Floor Area: 407 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F opaque aurraces R-38 Roof Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall Orientation Area X X x X X x X X X X X x U -Factor X X X X X x X X X X X X CLTD 1 S 407.0 0.0250 56.0 SW 204.0 0.0690 31.7 NW 112.0 0.0690 29.3 NE 197.0 0.0690 30.3 SE 156.0 0.0690 29.3 5.0 40.4 202 NW 0.0 28.7 9.0 38.5 347 NW 0.0 28.7 35.0 38.5 1,3491 NW 0.0 28.7 9.0 38.5 347 SE 0.0 28.7 5.0 35.8 179 SE Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration • Window Window Window Window Window Window Is I -age I otal Btu/hr 570 446 226 412 316 1,9701 Orientation Shaded Area X X X X X x x X X X GLF + + + + + + + + + + Unst-aded Area x X X X X x X X z _ GLF = = = = = = = = _ Btu/hr SW 0.0 28.7 5.0 40.4 202 SW 0.0 28.7 5.0 40.4 202 SW 0.0 28.7 5.0 40.4 202 NW 0.0 28.7 9.0 38.5 347 NW 0.0 28.7 35.0 38.5 1,3491 NW 0.0 28.7 9.0 38.5 347 SE 0.0 28.7 5.0 35.8 179 SE 0.0x 28.7+ 5.0X 35.8= 179 SE 0.0 28.7 5.0 35.E 179 Page Total 1 3,185 Internal Gain Btu/hr Occu ants El X Occup ants x 230 Btuh/occ. = 920 P P E ui ment X Dwelling Units X 1,6001 Watts/sqft = 1,6001 Infiltration: 1.os4 X 1.39 X 25.79 X = 1299 Air Sensible CFM ELA 4nST TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8.9 Latent Gain Btu/hr Occu ants X Occupants x 200 Btuh/occ. = 800 Infiltration: 4 771 x 1.39 x 25.79 x 0.00263 = 451 Air Latent CFM ELA n w TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,251 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 23 of 24 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date rana Residence 7/20/2007 oom Information Desicin Conditions Room Name: Casita Outdoor Dry Bulb Temperature:, 1120F Floor Area: 389 sf Outdoor Web Bulb Temperature: 78OF Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr R-21 Wall R-21 Wall R-21 Wall S 389.0 X X X X X X X X X X X X 0.0250 X X X X X X X X X X X X 56.0 = = = = = = = = = = SW 272.2 0.0690 31.7 NW 120.0 0.0690 29.3 NE 294.0 0.0690 30.3 SE 154.0 0.0690 29.3 SW 0.0 28.7 10.0 40.4 404 NW 0.0X 28.7+ 40.0): 38.5= 1,541 NE 0.0 28.7 10.0 47.6 476 NE 0.0 28.7 6.0 47.6 286 SE 0.0x 28.7+ 6.0} Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain Occupants 4 E ui ment 1 Inge 1 oral 545 595 243 615 312 2 309 Orientation Shaded Area X X X X X X X X GLF + + + + + + + + Unshaded Area Y }: }- X >, )t 7� Page GLF = = = = = _ Btu/hr SW 0.0x 28.7+ 3.8x. 40.4= 154 SW 0.0 28.7 24.0 40.4 970 SW 0.0 28.7 10.0 40.4 404 NW 0.0X 28.7+ 40.0): 38.5= 1,541 NE 0.0 28.7 10.0 47.6 476 NE 0.0 28.7 6.0 47.6 286 SE 0.0x 28.7+ 6.0} 35.8= 215 Total 4 046 Btu/hr X Occupants X 230 Btuh/occ. = 920 X Dwelling Units X 1,6001 Watts/sqft = 1,6001 Infiltration: 1.064 X 1.39 X 24.65 X F 1242 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10117 Latent Gain Btu/hr Occu ants E--41 X Occupants X 200 Btuh/oCC. = 800 Infiltration: 4771 X 1.39 X 24.65 X 0.00263 = 431 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,231 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 24 of 24