Loading...
07-2336 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 07-00002336 Property Address: 80240 VIA PESSARO APN: 772-550-014- - - Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 341394 Applicant:CJ` Architect or Engineer: LIU LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B :�OLicense No.: 533670 Date: �*01ont,actor: OWNER -BUILDER D CLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 1 am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERA11T Owner: ROBERT & GENEVIEVE P O BOX 1721 LA QUINTA, CA 92247 Contractor: SUNROSE CORPORATION 73091 COUNTRY CLUB PALM DESERT, CA 922 (760)773-6633 Lic. No.: 533670 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 12/13/07 ROBINSON WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 37701f`0. of the Labor Code, I shall forthwith c with those provisions. �V lt Date:pplicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that 1 have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this �coourntty two enter upon the above-mentioned property for inspectio uses. Date`(/ �� f/ 'Zignature (Applicant or Agent): Permit . . . MECHANICAL Additional desc . . LQPERAITT Application Number . . . . . 07-00002336 ------ Structure Information 4,696SF DWELLING/V-NR/RES-3/CLASS A -FR ----- Other struct info . . . . . CODE EDITION 2001/2004/2005 # BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG 620.00 PATIO SQ FTG 463.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 3563.00 ---------------------------------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE 1133.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 1486.50 Plan Check Fee 966.23 Issue Date . . . . Valuation . . . . 341394 Expiration Date 6/10/08 - Qty Unit Charge Per Extension BASE FEE 639.50 242.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,001-500,000 847.00 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 206.76 Plan Check Fee 51.69 Issue Date . . . . Valuation . . . . 0 Expiration Date 6/10/08 Qty Unit Charge Per Extension BASE FEE 15.00 4696.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 164.36 620.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 12.40 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 6/10/08 Qty Unit Charqe Per Exten9inn ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . . LQPERAITT Application Number Permit . . . . . . MECHANICAL Permit Fee . . . . 164.50 Issue Date . . . . Expiration Date . . 6/10/08 07-00002336 Plan Check Fee . . 41.13 Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 4.00, 9.0000 EA MECH FURNACE <=100K 36.00 1.00 11.0000 EA MECH FURNACE >100K 11.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 4.00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 1.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 16.50 6.00 6.5000 EA MECH VENT FAN 39.00 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . PLUMBING Additional desc.. Permit Fee . . . . 218.25 Plan Check Fee 54.56 Issue Date . . . . Valuation . . . . 0 Expiration Date 6/10/08 Qty Unit Charge Per Extension BASE FEE 15.00 24.00 6.0000 EA PLB FIXTURE 144.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 13.00 .7500 EA PLB GAS PIPE >=5 9.75 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 4,696SF DWELLING/V-NR/RES-3/CLASS A -FR THIS PERMIT DOES NOT INCLUDE BLOCKWALLS POOL AND SPA, OR DRIVEWAY APPROACH. 2001 CBC, CMC, CPC, 2004 CEC, 2005 ENERGY. November 30, 2007 4:12:57 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES. 353.48 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY RFVTRW FEE 9F F? DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE 15.00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES. 22.00 DIF PARKS/REC - RES 892.00 LQPERAIIT LQPERMIT Application Number . . . . . 07-00002336 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STRONG MOTION (SMI) - RES 34.13 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid Credited Due ----------------- Permit Fee Total ---------- 2091.01 ------------------------------ .00 .00 2091.01 Plan Check Total 1113.61 800.00 .00 313.61 Other Fee Total 4974.23 .00 .00 4974.23 Grand Total 8178.85 800.00 .00 7378.85 LQPERMIT CITY OF LA QUINTA SUB-CONTRACTOR. LIST�.����� O�� JOB ADDRESS.?-02-2160VIA�EaSARO PERMIT NUMBER OWNER � /���e�\S�ti1 _.___ _BUILDE This form shall be posted on the job with the Building Card at all times in a conspicuous_ place. Only persons appearing on this list or their employees are authorized to work ---i by tho Rifildinn Division Door to commencement of work. Failure to comply will result in a stoppage of work andlor the voidance f GG`(,r6lJ P.O. BOX 1504 APPLICATION ONLY Building 78-495 CALLE TAMPICO Addres Q Q / A, CALIFORNIA 92253 Owner BUILDING: TYPE CONST. OCC. GRP. mailing Address City Zip O l3—y yg r fly w a I Contractor Q� Address ' City Zip Tel. U)ZI Xci Z L90 2-7S' -`7 0, & Classif. fS 5--3-36-7 O IU& # Arch., Engr., .� Designer ity _ Zip State D Lic. r, LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure Is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or Im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars (5100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT .P. Number. Legal Description_ Project Description ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE I JSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE Sq. Ft.. Size 4/ 0 No. p No. Dw. Stories Units New Add ❑ Alter ❑ Repair ❑ Demolition ❑ / nn oq EstimatedIII Valu tion dor PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure ------ — �n TOTAL A ,. uF F ZI{iFitr�. REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE I JSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California_ Education Code 17620) Project Name: Robert Robinson (Hideaway_) Date: 12/12/07 Owner's Name: Robert Robinson _Phone No. (7§9)275-9091 Project Address: 80-240 Via Pessaro , La Quinta, CA 92253 Project Description: 1 Single Family Dwelling APN: 772.550-014 Tract #: Lot #'s: Type of Development: Residential XX Commercial Industrial Total Square Feet of Building Area: 4,696 sq. Ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct an&makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: 12/12/07 Signature: -Z s*••**sss"s******#*ss****#s#****#•s•t•t-*-*-*•**�*s****#�********s#************� SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT RAVE -BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 4,696 sq. ft. Amount per Sq.Ft. $ 3.48 Amount Collected $ 16,342.08 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Support Services Certificate issued by: Leticia C. Torres, Facilities Analyst Section 66020 of the Government Code asserted by Assembly Bi113081, effective January 1, 1997, requires that this District provide (I) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. LT:c/mvdocs/devfees/certificate of comDliance form tablesTO USF,.do, 1/16/03 T Oct 29 2007 2:29PM Jennie Robinson 10-29-07;01:50PM; Hideaway Properties f WIMN RECORDED MAIL TO: Robert Robinson & Genevieve Robinson PO Box 1711 La Quinta, CA 42253 MAIL. TAX STATEMENT TO: SAIvM AS ABOVE W-18IMicM.MICII V1 :760-777-1354 (This space for Recorder's use only) DOCUMENT TRANSFM TAX S XX . Computed on the consideration or value of property conveyed; OR Computed on the consideration of value less lifts or encumbrances remaining at the time of sale, Sigtlature of Declarant or Agent deterjahligg tax —Firm Name GPLP T DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, AID (` LA QUINTA PARTNERS, LLC, a Delawarelimited liability company } "Grantaie' hereby GRANT(S) to]&nBERT ROBINSON AbM 2pMYZ Y ROWNSON HUSBAND AM WIFE AS ("Grantee'), the real property located in the City ofLa Quints, County of Riverside, State of California, described as: See Legal Description attached hereto and incorporated herein as Exhibit "A,. SUBJECT TO all matters of record including, without limitation, the covenants and agreements described in Exhibit "A" attached hereto. Dated: January 20, 2003 t -L"27%9,1 l ND LA QUINTA PARTNERS, LLC, A Delaware limited liability company By: Nationwide Realty Investors, Ltd,, an Ohio limited liability company its managing m er ]By: Jos- h L. Arenson Authorized Representative p.3 # 2/ 4 Oct 29 2007 2:29PM Jennie Robinson 760-564-2318 p.4 10-29-07:01:50PM:Hideaway Properties :780-777-1354 s 31 4 EXMIRT "A," Lot 200 (the "Lot") of Amended Tract No. 29894.2 as shown on Subdivision Map (the sMap') recorded on December 12, 2002, in Book 327, Pages 56 to 88, inclusive, of Maps, in the OfEce of the Riverside County Recorder. . EXCEPTING AND RESERVING THEREFROM TO GRANTOR, and its successors, assigns, invitees, licensees and employees, together with the right to grant and txansfer all or a portion of the same, all easements and rights for access, ingress, egress, encroachment, maintenance, drainage, support, and for other purposes over the Association Maintenance Areas and other portion of the Lot, reserved to Grantor in the following instruments: 1. The Amended and Restated Declaration of Covenants. Conditions and Restrictions and Reservation of Easements for The Hideaway Owners Association (as amended or supplernent4 the "Declaration'j, recorded on December 13.2002, as Instrument No. 2002- 745939, of Official Records of Riverside County, California (the "Ofild I Records); 2. The Supplementary Declaration of Annexation of Property, recorded on March 21, 2003, as InsLnmient No. 2003.201647, of Official Records of Riverside Country, California FURTHER RESERVING THEREFROM, the right to enter the Lot for a tern of twelve (12) months following the recordation of ibis Grant Deed, to complete and repair any improvements or landscaping located thereon as determined necessary by Grantor, in its sole discretion, in order to comply with requirements for the recordation of the Final Tract Map, the grading of said Tract and/or in compliance with the requirements of applicable governmental agencies. Such entry by Grantor shat] be preceded by reasonable notice to Grantee before such entry. If this reservation of right of entry is not complied with by Grantee, Grantor may enforce this right of entry in a court of law. Grantee shaU be responsible for all damages arising out of said breach including attorneys' fees and court costs. This reservation of right of entry shall automatically expire twelve (12) uiomths from the recordation of this Grant Deed. FURTHER RBSERVING THEREFROM, an easement for landscaping purposes over the Southerly 11.5' feet thereof. Nonexclusive easements for access, ingress. egress, drainage, maintenance, serepairs ax►d for other purposes, all as described in the Declaration. Oct 29 2007 2:29PM Jennie Robinson 760-564-2318 10-29-07:01;50PM;Hide2way Properties ;760-777-1354 ` C" SUBJECT TO: 1. , Non delinquent general, special and supplemental real property taxes and assessments. 2. All other covenants, conditions, restrictions, reservations, easements, rights and rights-of-way of record including, without imitation, the Declaration and the Map for Tract No. 29894-1 Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in this Grant Deed, (b) grants to Granter and The Hideaway Owners Association such powers and rights as are set forth in the Declaration, and (c) accepts, covenants and agrees to be bound by and assume performance of all of the applicable provisions and requirements set forth in the Declaration, including Section 13.15 establishing the procedure for resolving disputes with Grantor, and the notice, which provisions and requirements are acknowledged to by reasonable and incorporated herein by this reference therew. This grant is conditioned upon the performance of such provisions and requirements as are to be perfbmed by Grantee under the Declaration. The restrictions on use and occupancy of the Lot are set forth in the Declaration to which this Grant Deed is specifically and expressly made subject. GRANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING, granting timto Grantor and The Hideaway Owners Association such powers and rights which are set forth in the Declaration defined above, on 3 , 2003. Robj Robinson Genevieve Robinson STATE OF ) ss. COUNTY OF ) On 2003, before me, the undersigned,•anotary to, personally appeared Robert Robinson and Genevieve Robinson, public in and r said �S personally known to me (or proved to me on the basis of satisfactory evidence) to be the persons whose names are subscribed to the within Inst nunent and acknowledged to me that they executed the same in their authorized capacities, and that by their signature on the instrument the persons, or the entity upon behalf of which the persons acted, executed the instrument. WITNESS MY HAND AND OFFICIAL SEAL. (: SEAL] ignature (D P.5 # 4! 4 ` e WC3ER ASSOC/A TES 620 CHELHAAl WAY • SANTA BARBARA • CA • 93108 • TEL: 805-969-7887 ENERGY COMPLIANCE SUMMARY (MICROPAS7 VERSION 7.3 COMPUTER METHOD) ROBINSON/SMALL RESIDENCE (REVISED) 80240 VIA PESSARO LA QUINTA, CALIFORNIA F4X. 805-969-0425 The following features were used to demonstrate compliance with California Energy Regulations. This information is included in the plans and specifications submitted for building permit approval. Construction must be consistent with this information unless any changes have received prior approval from the building inspection agency AREA OF BUILDING SUBJECT TO COMPLIANCE: 4696 SQUARE FEET GROSS CONDITIONED FLOOR AREA. CLIMATE ZONE: CLIMATE ZONE 15. MINIMUM BUILDING ENVELOPE INSULATION LEVELS: 1. FRAME WALLS: MINIMUM R-19 (5.5") BATT INSULATION. 2. ROOF/CEILING: MINIMUM R-38 (11.0") BATT INSULATION. GLAZING: CITY OF Uk QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DAT ;Dr13Y 1. DOUBLE PANE WINDOWS: 194.6 S.F., WOOD SASH, LOW -E COATINGS WITH U -VALUES OF 0.40 OR LESS & SOLAR HEAT GAIN COEFFICIENTS OF 0.40 OR LESS. 2. DOUBLE PANE DOORS: 646.1 S.F., WOOD DOORS, 688.1 S.F., WOOD FRAME, LOW -E, COATINGS WITH U - VALUES OF 0.40 OR LESS & SOLAR HEAT GAIN COEFFICIENTS OF 0.40 OR LESS. 3. SINGLE PANE ENTRY DOOR & TRANSOM: 42 S.F., METAL FRAME, U -VALUE OF 0.99 DR LESS & SOLAR HEAT GAIN COEFFICIENT OF 0.80 OR LESS. 4. DOUBLE PANE SKYLIGHTS: 12.5 S.F., WOOD FRA\4E, LOW -E COATINGS WITH U -VALUES OF 0.40 OR LESS & SOLAR HEAT GAIN COEFFICIENTS OF 0.40 OR LESS. OVERHANGS & SHADING DEVICES: 1. LOGGIA SHADES DOORS #8 & #9. 2. 2.0 FT. AVERAGE EAVE OVERHANG AT 2ND FLOOR & TOWER. THERMAL MASS: D NONE CALCULATED FOR COMPLIANCE PURPOSES. HVAC SYSTEM(S): N0 By � 1. FOUR ZONED HIGH EFFICIENCY CONDENSING FURNACES (94% AFUE) WIT IGH EFFICIENCY A/C CONDENSERS (15 SEER); SEE CERTIFICATE OF COMPLIANCE FOR EQUIPMENT SPECIFICATIONS. 2. SEPARATE DUCTLESS SPLIT SYSTEM A/C TO COOL WINE ROOM; SEE CERTIFICATE OF COMPLIANCE FOR EQUIPMENT SPECIFICATIONS. 3. HVAC DUCTS TO BE INSULATED WITH R-8 DUCT INSULATION. DOMESTIC WATER HEATING SYSTEM: 1. A\IERICAN "POLARIS" CONDENSING WATER HEATERS, 100 -GAL. GAS, 199,000 BTUF INPUT, 95% RECOVERY EFFICIENCY OR EQUAL; TWO UNITS INSTALLED. 2. HOIT WATER RECIRCULATION LOOP WITH TIME & TEMPERATURE CONTROLS; ALL HOT WATER LINES INSULATED WITH R-4 PIPE INSULATION. ALL MANDA TORY FEA TURES PER FORM MF -1R CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 1 Project Title.......... ROBINSON/SMALL RESIDENCE Date..11/06/07 20:53:31 Pro'ect � Add 80240 VIA PESSARO ******* ress........ LA QUINTA CALIFORNIA *v7.30* Documentation Author... David Inger ******* Building Permit # Inger Associates 620 Chelham Way Plan Check / Date Santa Barbara, CA 93108 805-969-1881 Field Check/ Date Climate Zone........... 15 Compliance Method...... MICROPAS7 v7.30 for 2005 Standards by Enercomp, Inc. MICROPAS7 v7.30 File-ROBINSON Wth-CTZ15S05 Program -FORM CF -1R User#-MP1503 User -Inger Associates Run -COMPLIANCE MICROPAS7 ENERGY USE SUMMARY II Energy Use_ Standard . Proposed Compliance (kTDV/sf-yr) Design Design Margin �I Space Heating.......... 2.89 2.41 0.48 Space Cooling.......... 71.57 71.82 -0.25 Water Heating.......... 5.15 4.56 0.59 Total 79.61 78.79 0.82 I! *** Building Complies with Computer Performance GENERAL INFORMATION HERS Verification.......... Conditioned Floor Area..... Building Type .............. Construction Type ......... Fuel Type ................. Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... Not Required 4696 sf Single Family Detached New NaturalGas Front Facing 180 deg (S) 1 2 FullYear Slab On Grade 1 46960 cf 3460 sf 19.9 % of floor area 0.44 Btu/hr-sf-F 0.42 10 ft CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 2 Project Title.......... ROBINSON/SMALL RESIDENCE Date..11/06/07 20:53:31 MICROPAS7 v7.30 File-ROBINSON Wth-CTZ15S05 Program -FORM CF -1R User#-MP1503 User -Inger Associates R -in -COMPLIANCE FENESTRATION SURFACES BUILDING ZONE INFORMATION Area Floor # of # of Cond- Thermo- Vent Vent Verified Orientation Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) HDusewrap Residence 4696 46960 1.00 4.0 Yes Setback 8.0 Standard No 0.400 270 90 OPAQUE SURFACES Wind Left (W) U- Sheath- Solar Appendix' 270 Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments 1 Wall Wood 184 0.071 19 0 180 90 Yes IV.9 A23 2 Wall Wood 1046 0.071 19 0 225 90 Yes IV.9 A23 3 Wall Wood 735 0.071 19 0 315 90 Yes IV.9 A23 4 Wall Wood 160 0.071 19. 0 0 90 Yes IV.9 A23 5 Wall Wood 1021 0.071 19 0 45 90 Yes IV.9 A23 6 Wall Wood 76 0.071 19 0 90 90 Yes IV.9 A23 7 Wall Wood 906 0.071 19 0 135 90 Yes IV.9 A23 8 RoofRad Wood 3448 0.025 38 0 n/a 0 Yes IV.1 A18 (E) 4.0 0.400 PERIMETER LOSSES 90 90 9 Wind Appendix (E) 31.5 Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments 9 SlabEdge 338 0.730 R-0 No IV.26 Al 11 FENESTRATION SURFACES Exterior Shade Type Location/Comments Standard WDW.B/WOOD SASE Standard WDW.0/WOOD SASE Standard WDW.D/WOOD SASE Standard WDW.E/WOOD SASS_ Standard WDW.F/WOOD SASE Standard WDW.G/WOOD SASH Standard WDW.H/WOOD SASH Standard WDW.I/WOOD SASH Standard WDW.J/WOOD SASH Standard WDW.K/WOOD SASH Standard WDW.L/WOOD SASH Standard WDW.M/WOOD SASH Standard WDW.N/WOOD SASH Standard WDW.O/WOOD SASH Standard WDW.P/WOOD SASH Area U- Act Orientation (sf) factor SHGC Azm Tilt 1 Wind Left (W) 4.0 0.400 0.400 270 90 2 Wind Left (W) 4.0 0.400 0.400 270 90 3 Wind Left (W) 27.5 0.400 0.400 270 90 4 Wind Left (W) 9.0 0.400 0.400 270 90 5 Wind Left (W) 9.0 0.400 0.400 270 90 6 Wind Right (E) 70.0 0.400 0.400 90 90 7 Wind Right (E) 4.0 0.400 0.400 90 90 8 Wind Right (E) 4.0 0.400 0.400 90 90 9 Wind Right (E) 31.5 0.400 0.400 90 90 10 Wind Right (E) 5.0 0.400 0.400 90 90 11 Wind Right (E) 4.2 0.400 0.400 90. 90 12 Wind Right (SE) 4.2 0.400 0.400 135 90 13 Wind Front (S) 4.2 0.400 0.400 180 90 14 Wind Left (W) 5.0 0.400 0.400 270 90 15 Wind Left (W) 9.0 0.400 0.400 270 90 Exterior Shade Type Location/Comments Standard WDW.B/WOOD SASE Standard WDW.0/WOOD SASE Standard WDW.D/WOOD SASE Standard WDW.E/WOOD SASS_ Standard WDW.F/WOOD SASE Standard WDW.G/WOOD SASH Standard WDW.H/WOOD SASH Standard WDW.I/WOOD SASH Standard WDW.J/WOOD SASH Standard WDW.K/WOOD SASH Standard WDW.L/WOOD SASH Standard WDW.M/WOOD SASH Standard WDW.N/WOOD SASH Standard WDW.O/WOOD SASH Standard WDW.P/WOOD SASH CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 3 Project Title.......... ROBINSON/SMALL RESIDENCE Date..11/06/07 20:53:31 MICROPAS7 v7.30 File-ROBINSON Wth-CTZ15S05 Program -FORM CF -1R User#-MP1503 User -Inger Associates Run -COMPLIANCE FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments 16 Door Front (SW) 42.0 1.250 0.800 225 90 Standard DOOR.1/WROUGHT IRON FRAM 17 Door Front (S) 17.5 0.530 0.650 180 90 Standard DOOR.2/1/2 GLASS DOOR 18 Door Back (N) 80.0 0.400 0.400 0 90 Standard DOOR.7/WOOD FRAME 19 Door Back (N) 88.0 0.400 0.400 0 90 Standard DOOR.8/WOOD FRAME 20 Door Left (W) 81.4 0.400 0.400 270 90 Standard DOOR.9/WOOD FRAME 21 Door Back (N) 162.0 0.400 0.400 0 90 Standard DOOR.10/WOOD FRAME 22 Door Front (S) 44.0 0.400 0.400 180 90 Standard DOOR.12/WOOD FRAME 23 Door Left (W) 44.0 0.400 0.400 270 90 Standard DOOR.13/WOOD FRAME 24 Door Left (W) 44.0 0.400 0.400 270 90 Standard DOOR.14/WOOD FRAME 25 Door Front (S) 35.0 0.400 0.400 180 90 Standard DOOR.30/WOOD FRAME 26 Door Back (N) 88.0 0.400 0.400 0 90 Standard DOOR.31/WOOD FRAME 27 Skyl Horz 12.5 0.400 0.400 180 0 None SKYLITES/VELUX OR EQUAL OVERHANGS -Window- Overhang Area Left Right Surface (sf) Width Height Depth Height Extension Extension 1 Window 4'.0 n/a 5.5 2.0 1.5 n/a n/a 2 Window 4.0 n/a 5.5 2.0 1.5 n/a n/a 3 Window 27.5 n/a 5.5 2.0 1.5 n/a n/a 4 Window 9.0 n/a 5.5 2.0 1.5 n/a n/a 5 Window 9.0 n/a 5.5 2.0 1.5 n/a n/a 6 Window 70.0 n/a 5:5 2.0 1.5 n/a n/a 7 Window 4.0 n/a 5.5 2.0 1.5 n/a n/a 8 Window 4.0 n/a 5.5 2.0 1.5 n/a n/a 9 Window 31.5 n/a 5.5 2.0 1.5 n/a n/a 10 Window 5.0 n/a 5.5 2.0 1.5 n/a n/a 11 Window 4.2 n/a 5.5 2.0 1.5 n/a n/a 12 Window 4.2 n/a 5.5 2:0 1.5 n/a n/a 13 Window 4.2 n/a 5.5 2.0 1.5 n/a n/a 14 Window 5.0 n/a 5.5 2.0 1.5 n/a n/a 15 Window 9.0 n/a 5.5 2.0 1.5 n/a n/a 16 Door 42.0 n/a 9.0 2.0 1.5 n/a n/a 17 Door 17.5 n/a 5.5 2.0 1.5 n/a n/a 18 Door 80.0 n/a 9.0 2.0 1.5 n/a n/a 19 Door 88.0 n/a 8.0 2.0 1.5 n/a n/a 20 Door 81.4 n/a 8.0 2.0 1.5 n/a n/a 21 Door 162.0 n/a 9.0 2.0 1.5 n/a n/a 22 Door 44.0 n/a 9.0 2.0 1.5 n/a n/a 23 Door 44.0 n/a 9.0 2.0 1.5 n/a n/a 24 Door 44.0 n/a 9.0 2.0 1.5 n/a n/a 25 Door 35.0 n/a 9.0 2.0 1.5 n/a n/a 26 Door 88.0 n/a 9.0 2.0 1.5 n/a n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 4 Project Title.......... ROBINSON/SMALL RESIDENCE Date..11/06/07 20:53:31 MICROPAS7 v7.30 File-ROBINSON Wth-CTZ15S05 Program -FORM CF -1R User#-MP1503 User -Inger Associates Run -COMPLIANCE SLAB SURFACES HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type (Btu/hr) (Btu/hr) (Btu/hr) (Btu/hr) Furnace 90644 n/a n/a n/a ACSplit n/a 79359 98484 n/a Sizing Location............ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R -value Leakage Area Ducts Furnace Attic R-8 No No No ACSplit Attic R-8 No No No Area Slab Type (sf) Standard Slab 3460 HVAC SYSTEMS Verified Verified Verified Verified Verified Miaximum System Minimum Refrig Charge Adequate Fan Watt Cooling Type Efficiency EER or TXV Airflow Draw Opacity Furnace 0.940 AFUE n/a n/a n/a n/a n/a ACSplit 15.00 SEER No No No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type (Btu/hr) (Btu/hr) (Btu/hr) (Btu/hr) Furnace 90644 n/a n/a n/a ACSplit n/a 79359 98484 n/a Sizing Location............ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R -value Leakage Area Ducts Furnace Attic R-8 No No No ACSplit Attic R-8 No No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 5 Project Title.......... ROBINSON/SMALL RESIDENCE Date..11/06/07 20:53:31 MICROPAS7 v7.30 File-ROBINSON Wt_z-CTZ15S05 Program -FORM CF -1R User#-MP1503 User -Inger Associates Run-COMPLIANCE- WATER un-COMPLIANCE WATER HEATING SYSTEMS Number Tank E<ternal Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R -value 1 Large Gas Recirc/TimeTemp 1 n/a 100 R-n/a WATER HEATING SYSTEMS DETAIL Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R -value Light 1 Large 0.95 n/a 0.01 R- n/a n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a Radiant Barrier. This building incorporates a non-standard Water Heating System. REMARKS FAU1/AC1 (MAIN LIVING AREA): BRYANT 350MAV0060100, GAS CONDENSING 100,000 BTUH INPUT, 94,000 BTUH OUTPUT, 94% AFUE, WITH 598BNO60 OUTDOOR CONDENSER, 60,000 BTUH OUTPUT 15 SEER, OR EQUAL. FAU2/AC2 (BEDRMS 2&3): BRYANT 350MAV036040, GAS CONDENSING, 40,000 BTUH INPUT, 38,000 BTUH OUTPUT, 95% AFUE, WITH 598BNO36 OUTDOOR CONDENSER, 36,000 BTUH OUTPUT, 15 SEER, OR EQUAL. -FAU3/AC3 (MASTER BEDRM): BRYANT 350MAV036040, GAS CONDENSING, 40,000 BTUH INPUT, 38,000 BTUH OUTPUT, 95% AFUE, WITH 598BNO36 OUTDOOR CONDENSER, 36,000 BTUH OUTPUT, 15 SEER, OR EQUAL. FAU4/AC4 (2ND FLOOR):• BRYANT 350MAV036040, GAS CONDENSING, 40,000 BTUH INPUT, 38,000 BTUH OUTPUT, 95% AFUE, WITH 598BNO36 OUTDOOR CONDENSER, 36,000 BTUH OUTPUT, 15 SEER, OR EQUAL. AHU-5 (WINE ROOM): MITSUBISHI MSY/MVY-A15NA, SPLIT SYSTEM, DUCTLESS, COOLING ONLY, 15,000 BTUH OUTPUT 15 SEER, OR EQUAL. ALL HVAC DUCTS TO BE INSULATED WITH R-8 DUCT INSULATION. WATER HEATER: AMERICAN POLARIS PGC3-100-199, 100 -GAL., CONDENSING GAS, 95% RECOVERY EFFICENCY, OR EQUAL. HOT WATER RECIRCULATION LOOP WITH TIME/TEMP CONTROLS. ALL HOT WATER LINES INSULATED WITH R-4 PIPE INSULATION. CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 6 Project Title.......... ROBINSON/SMALL RESIDENCE Date..11/06/07 20:53:31 MICROPAS7 v7.30 File-ROBINSON Wth-CTZ15S05 Program -FORM CF -1R User#-MP1503 User -Inger Associates Run -COMPLIANCE REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and perfo-mance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulatio-is to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER Name.... BOB EASTON AIA Name.... Company. BOB EASTON AIA ARCHITECT Company. Address. 1486 EAST VALLEY ROAD Address. MONTECITO CA 93108 Phone... 805=969-5051 Phone... License. Signed.. � 1jJ ///Z/Q�Signed.. (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed. (date) DOCUMENTATION AUTHOR David Inger Inger Associates 620 Chelham Way Santa Barbara, CA 93108 HVAC SIZING HVAC Page 1 Project Title.......... ROBINSON/SMALL RESIDENCE Date..11/06/07 20:53:31 Pro'ect Address 80240 VIA PESSARO ******* LA QUINTA CALIFORNIA *v7.30* Documentation Author... David Inger ******* Building Permit # Inger Associates 620 Chelham Way Plan Check / Date Santa Barbara, CA 93108 805-969-1881 Field Check/ Date Climate Zone........... 15 Compliance Method...... MICROPAS7 v7.30 for 2005 Standards by Enercomp, Inc. MICROPAS7 v7.30 File-ROBINSON Wth-CTZ15S05 Program -HVAC SIZING User#-MP1503 User -Inger Associates Run -COMPLIANCE GENERAL INFORMATION Floor Area ................. Volume..................... Front Orientation.......... Sizing Location............ Latitude ................... Winter Outside Design...... Winter Inside Design ......... Summer Outside Design...... Summer Inside Design....... Summer Range ............... Interior -Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 4696 sf 46960 cf Front Facing 180 deg (S) LA QUINTA 33.8 degrees 26 F 70 F 111 F 75 F 34 F Yes Yes Yes 0.24 HEATING AND COOLING LOAD SUMMARY Sensible Load .................... 90644 79359 Latent Load ...................... n/a 19125 Minimum Total Load 90644 98484 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to conside.= all factors when selecting the HVAC equipment. Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 32745 14349 Glazing Conduction and Solar..... 18092 31154 Infiltration ..................... 25019 15317 Internal Gain .................... n/a 2520 Ducts ............................ 14789 16018 Sensible Load .................... 90644 79359 Latent Load ...................... n/a 19125 Minimum Total Load 90644 98484 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to conside.= all factors when selecting the HVAC equipment. FORMATTED INPUT FORMAT Page 1 MICROPAS7 v7.30 File-ROBINSON Wth-CTZ15S05 Program -FORMAT Run -COMPLIANCE Project-ROBINSON/SMALL RESIDENCE Date -11/06/07 Input file 'ROBINSON' last edited on 11/06/07 BUILDING RUN FEATURES RUN 1> RUN TITLE (25 char) .............................. .COMPLIANCE 2> PROJECT TITLE (25 char) ROBINSON/SMALL RESIDENCE 3> DOCUMENTATION AUTHOR (25 char) .................. David Inger BUILDING 4> TYPE (Single, SingleAttached, MultiFamily) ...... Single 5> CONSTRUCTION (New, Existing+Add+Alter, etc) New 6> FRONT ORIENTATION (Compass deg or Cardinal) ..... 180 7> NUMBER OF STORIES (1 or more) ................. 2 8> FUEL TYPE (NaturalGas, Propane) ................. NaturalGas 9> COMPLIANCE RUN (Compliance, Research, C -HERS) ... Compliance SITE AND WEATHER DATA 1> WEATHER DATA TYPE (FullYear) .................... FullYear 2> CEC CLIMATE ZONE (01 thru 16) ................... 15 HVAC SIZING 1> SIZING LOCATION (25 char) ....................... LA QUINTA CALCULATIONS AND REPORTS CALCULATIONS 1> COMPUTER PERFORMANCE TYPE (Both,Stand,Prop) ..... Both 2> COMPUTER PERFORMANCE CALCULATION (Yes, No) ...... Yes 3> WATER HEATING CALCULATION (Yes, No) ............. Yes 4> HVAC SIZING CALCULATION (Yes, No) ............... Yes COMPLIANCE REPORTS 5> PRINT CF -1R REPORT (Yes, No) .................... Yes 6> PRINT MF -1R REPORT (Yes, No, Name) .............. Yes 7> PRINT WS -5R LIGHTING WORKSHEET (Yes, No, Name) .. No 9> PRINT HVAC SIZING REPORT (Yes, No, Detailed) .... Yes OTHER 10> PRINT INPUT DATA (Yes, No, Unformatted) ........ Yes 12> STANDARD DESIGN INPUT DATA (Save, NoSave) ...... NoSave ZONE ZONES #> NUMBER OF ZONES (15 maximum) .................... 1 ZONE 'HOUSE' 1> ZONE NAME ....................................... HOUSE 2> CONDITIONED (Yes, No) ........................... Yes 3> ZONE TYPE ....................................... Residence 4> FLOOR AREA (sf)................................. 4696 FORMATTED INPUT FORMAT Page 2 MICROPAS7 v7.30 File-ROBINSON Wth-CTZ15S05 Program -FORMAT Run -COMPLIANCE Project-ROBINSON/SMALL RESIDENCE Date -11/06/0' 5> VOLUME (cuft)................................... 46960 6> NUMBER OF DWELLING UNITS ........................ 1.0 CREDITS 7> HOUSEWRAP/VERIFIED AIR LEAKAGE (Yes,No,SLA) ..... No 8> RADIANT BARRIER (Yes, No, CoolRoof) ............. Yes 9> VERIFIED INSULATION QUALITY (Yes, No) ........... No HVAC SYSTEM 10> NUMBER OF SYSTEMS SERVING ZONE ................. 1 11> HEATING SYSTEM NAME ............................ HI.EFF 12> COOLING SYSTEM NAME HI.EFF 13> DUCT.SYSTEM NAME ............................... DUCTS.R.8 14> NATURAL VENTILATION SYSTEM NAME ................ TWO.STORY 15> FAN VENTILATION SYSTEM NAME .................... None 16> THERMOSTAT NAME ................................ Setback HVAC SIZING 17> NUMBER OF PEOPLE/UNIT (occupants/unit) 4 OPAQUE OPAQUE SURFACES #> NUMBER OF SURFACES (100 maximum) SURFACE 9 TERISTIC OPAQUE AREA 1 —2- SOLAR OPAQUE ZONE OR 2> SURFACE OR 3> PLAN GAINS CHARAC- OPAQUE LOCATION/ Door NAME LENGTH TILT AZIMUTH (Y/N) TERISTICS NAME COMMENTS n/a —1 —2— —3— —4— —5— 6 —7 8- 1> S.WALL 184 Vert 0 Yes WALL.R19 HOUSE 2> SW.WALL 1046 Vert 45 Yes WALL.R19 HOUSE 3> NW.WALL 735 Vert 135 Yes WALL.R19 HOUSE 4> N.WALL 160 Vert 180 Yes WALL.R19 HOUSE 5> NE.WALL 1021 Vert 225 Yes WALL.R19 HOUSE 6> E.WALL 76 Vert 270 Yes WALL.R19 HOUSE 7> SE.WALL 906 Vert 315 Yes WALL.R19 HOUSE 8> ROOF 3448 Horz n/a Yes ROOF.R38 HOUSE 9> SLAB 338 Horz n/a No SLAB.EDGE HOUSE OPAQUE CHARACTERISTICS #> NUMBER OF CHARACTERISTICS GLAZING GLAZING SURFACES (50 maximum) OPAQUE OPAQUE CAV- CHARAC- SURFACE FRAME TERISTIC TYPE OR 1 —2- 1> WALL.R19 Wall 2> ROOF.R38 Roof 3> SLAB.EDGE SlabEdge 4> DOOR Door GLAZING GLAZING SURFACES (50 maximum) .......... 4 LOOKUP CAV- SHEATH- U -FAC FRAME ITY ING OR TYPE R-VAL R-VAL F-VAL —3— —4— —5— —6— n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a #> NUMBER OF SURFACES (100 maximum) ................ 27 APP APPENDIX IV IV LOOKU? LOOKUP NAME —7— 8 Yes W.19.3X6.24 Yes R.38.?4 Yes EDGE.EXT Yes DOOR FORMATTED INPUT FORMAT Page 3 MICROPAS7 v7.30 File-ROBINSON Wth-CTZ15S05 Program -FORMAT Run -COMPLIANCE Project-ROBINSON/SMALL RESIDENCE Date -11/06/07 GLAZING CHARACTERISTICS #> GLAZING maximum) ......... 6 GLAZING OVERHANG INT/EXT ZONE OR SURFACE AREA SURFACE PLAN CHARAC- SIDE FIN SHADE OPAQUE TYPE NAME (sf) TILT AZIMUTH TERISTICS NAME NAME NAME 5- -1 -2- -3- -4- 5 6 7 -8- 1> WDW.B 4 Vert 90 DOUBLE OH.A None HOUSE 2> WDW.0 4 Vert 90 DOUBLE OH.A None HOUSE 3> WDW.D 27.5 Vert 90 DOUBLE OH.A None HOUSE 4> WDW.E 9 Vert 90 DOUBLE OH.A None HOUSE 5> WDW.F 9 Vert 90 DOUBLE OH.A None HOUSE 6> WDW.G 70 Vert 270 DOUBLE OH.A None HOUSE 7> WDW.H 4 Vert 270 DOUBLE OH.A None HOUSE 8>. WDW.I 4 Vert 270 DOUBLE OH.A None HOUSE 9> WDW.J 31:5 Vert 270 DOUBLE OH.A None HOUSE 10> WDW.K 5 Vert 270 DOUBLE OH.A None HOUSE ll> WDW.L 4.2 Vert 270 DOUBLE OH.A None HOUSE 12> WDW.M 4.2 Vert 315 DOUBLE OH.A None HOUSE 13> WDW.N 4.2 Vert 0 DOUBLE OH.A None HOUSE 14> WDW.O 5 Vert 90 DOUBLE OH.A None HOUSE 15> WDW.P 9 Vert 90 DOUBLE OH.•A None HOUSE 16> DOOR.1 42 Vert 45 SNG.MTL OH.B None HOUSE 17> DOOR.2 17.5 Vert 0 DUTCH.DR OH.A None HOUSE 18> DOOR.7 80 Vert 180 DBL.FRDR OH.B None HOUSE 19> DOOR.8 88 Vert 180 DBL.SLDR LOGGIA None HOUSE 20> DOOR.9 81.4 Vert 90 DBL.SLDR LOGGIA None HOUSE 21> DOOR.10 162 Vert 180 DBL.FRDR OH.B None HOUSE 22> DOOR.12 44 Vert 0 DBL.FRDR OH.B None HOUSE 23> DOOR.13 44 Vert 90 DBL.FRDR OH.B None HOUSE 24> DOOR.14 44 Vert 90 DBL.FRDR OH.B None HOUSE 25> DOOR.30 35 Vert 0 DBL.FRDR OH.B None HOUSE 26> DOOR.31 88 Vert 180 DBL.FRDR OH.B None HOUSE 27> SKYLITES 12.5 Horz n/a DBL.SKY None None HOUSE GLAZING CHARACTERISTICS #> NUMBER OF CHARACTERISTICS (100 maximum) ......... 6 GLAZING GLAZING CHARAC- SURFACE U- TERISTICS TYPE FACTOR SHGC DESCRIPTION 1 -2 -3- -4- 5- 1> DOUBLE Window 0.40 0.40 WOOD SASH 2> DBL.FRDR Door 0.40 0.40 WOOD FRAME 3> DBL.SLDR Door 0.40 0.40 WOOD FRAME 4> SNG.MTL Door 1.25 0.80 WROUGHT IRON FRAME 5> DUTCH.DR Door 0.53 0.65 1/2 GLASS DOOR 6> DBL.SKY Skylight 0.40 0.40 VELUX OR EQUAL OVERHANGS AND SIDE FINS #> NUMBER OF OVERHANGS OVERHANG (50 maximum) ................ 3 SIDE FIN GLAZ GLAZ NAME WDTH HGHT -1 -2- -3- 1> OH.A n/a 5.5 2> OH.B n/a 9.0 3> LOGGIA n/a 8.0 OVER OVER LEFT LEFT LEFT RGHT RGHT RGHT OVER OVER LEFT RGHT FIN FIN FIN FIN FIN FIN DPTH HGHT EXT EXT EXT DPTH HGHT EXT DPTH HGHT -4- -5- -6- -7- -8- -9- -10- -11- -12- -13- 2.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 2.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 2.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a FORMATTED INPUT FORMAT Page 4 MICROPAS7 v7.30 File-ROBINSON Wth-CTZ15S05 Program -FORMAT Run -COMPLIANCE Project-ROBINSON/SMALL RESIDENCE Date -11/06/07 INTERIOR AND EXTERIOR SHADING #> NUMBER OF SHADES (25 maximum) ................... 2 INT/EXT INTERIOR EXTERIOR SHADE SHADE SHADE NAME TYPE TYPE 1 2 3 1> STANDARD Standard Standard 2> SHADESCRN Standard Woven MASS MASS SURFACES #> NUMBER OF SURFACES (50 maximum) MASS MASS SURFACE AREA CHARAC- NAME (sf) TERISTICS 1 —2— 3 1> SLAB 3.460 SLAB.CVR MASS CHARACTERISTICS 1 ZONE NAME LOCATION/COMMENTS 4 5 HOUSE SLAB FOOTPRINT AREA #> NUMBER OF CHARACTERISTICS (25 maximum) .......... 1 MASS HEATING THICK SURF- VOLUME CON- CHARAC- GAS NESS ACE HEAT DUCT- TERISTIC MASS TYPE (in) R-VAL CAP IVITY UIMC 1 2 —3— —4— —5— —6— —7- 1> SLAB.CVR S1abOnGrade 3.5 2.0 28 0.98 n/a HVAC HEATING SYSTEMS #> NUMBER OF HEATING SYSTEMS (25 maximum) .......... 1 HEATING HEATING COOLING HEATPUMP HYDRONIC SYSTEM SYSTEM GAS ELECTRIC WATER HEATING NAME TYPE AFUE HSPF SYSTEM NAME 1 2 —3— 4 5 1> HI.EFF Furnace 0.94 n/a None COOLING SYSTEMS #> NUMBER OF COOLING SYSTEMS (25 maximum) .......... 1 COOLING COOLING VERIF VERIF VERIF SYSTEM SYSTEM VERIF REFRIG AIR VERIF COOL NAME TYPE SEER EER OR TXV FLOW FAN CAP 1 2 –3— —4— —5— —6— —7— —8- 1> HI.EFF ACSplit 15 No No No No No DUCT SYSTEMS #> NUMBER OF DUCTS (25 maximum) 1 FORMATTED INPUT FORMAT Page 5 MICROPAS7 v7.30 File-ROBINSON Wth-CTZ15S05 Program -FORMAT Run -COMPLIANCE Project-ROBINSON/SMALL RESIDENCE Date -11/06/07 DUCT DUCT HEATING COOLING SYSTEM INSUL DUCT DUCT NAME R -VALUE LOCATION LOCATION 1 —2— 3 4- 1> DUCTS.R.8 8.0 Attic Attic NATURAL VENTILATION SYSTEMS WATER HEATING NATURAL NATURAL HEIGHT VENTILATION AREA SYSTEM NAME TYPE —1- 1> ONE.STORY 2> TWO.STORY 3> CALC.HEIGHT 4> CRAWL.VENT WATER HEATING NATURAL INLET HEIGHT VENTILATION AREA DIFF TYPE PER ZONE (ft) 2 3 —4— Standard 0 2.0 Standard 0 8.0 Standard 0 8.9 Special 1.4 0 WATER HEATING SYSTEMS VERIF VERIF VERIF SURFACE BURIED LEAKAGE AREA DUCT —5 —6— —7— No No No #> NUMBER OF WATER HEATING SYSTEMS (25 maximum) .... 1 WATER WATER # OF HYDRON[IC/ HEATING HEATING HEATER/BOILER HEATERS/BOILERS RECIRC NAME TYPE SYSTEM NAME INSTALLED SYSTEM NAME 1 2 3— —4- 4 1> 1> WTR.HTR DHW GAS.STOR 1 None HEATER/BOILER.SYSTEMS #> NUMBER OF HEATER/BOILER SYSTEMS (25 maximum) .... 1 HEATER/BOILER SYSTEM 'GAS.STOR' 1> HEATER/BOILER SYSTEM NAME ....................... 2> TANK TYPE (Storage, Instantaneous, etc.) ........ 3> HEATER ELEMENT TYPE (Electric, Gas, HeatPump) ... 4> DISTRIBUTION TYPE (Standard, PointOfUse, etc.) .. 5> ENERGY FACTOR ................................... 6> TANK VOLUME (gallons) ........................... 7> RATED INPUT (Btu/hr) ........................ 9> PILOT LIGHT SIZE (Btu/hr) ....................... 10> EXTERNAL BLANKET R -VALUE (hr-sqft-F/Btu) ....... 12> RECOVERY EFFICIENCY (fraction) ................. 13> STANDBY LOSS (fraction) ........................ WATER HEATING CREDIT 14> CREDIT TYPE (None, Solar, WoodStove) ........... HYDRONIC/RECIRCULATION SYSTEMS GAS.STOR Large Gas Recirc/TimeTemp n/a 100 199000 n/a n/a 0.95 0.01 None #> NUMBER OF HYDRONIC/RECIRC SYSTEMS (25 maximum) .. 1 HYDRONIC/RECIRC SYSTEM 'RADIANT' 1> HYDRONIC SPACE HEATING SYSTEM NAME RADIANT 2> TYPE OF DELIVERY (FanCoil, Radiant, Baseboard) .. Radiant FORMATTED INPUT FORMAT Page 6 MICROPAS7 v7.30 File-ROBINSON Wth-CTZ15S05 Program -FORMAT Run -COMPLIANCE Project-ROBINSON/SMALL RESIDENCE Date -11/06/07 PIPE IN UNCONDITIONED SPACE 3> PIPE LENGTH (ft) ................................ 0 4> PIPE DIAMETER (in) 0.5 5> PIPE INSULATION THICKNESS (in) .................. 0.75 6> PIPE INSULATION CONDUCTIVITY (Btu/hr-ft-F)....... 0.023 PUMPS (when used with electric storage water heaters only) 7> PUMP POWER (Watts) .............................. n/a NOTES ADDRESSES AND PHONES #> DISPLAY ADDRESSES AND PHONES (Yes, No) ........... Yes PROJECT 1> ADDRESS (25 char) . ............................... 80240 VIA PESSARO 2> CITY (25 char) ................................. LA QUINTA CALIFORNIA DESIGNER OR OWNER 3> CONTACT (25 char) ........... 4> FIRM (25 char) .............. 5> ADDRESS (25 char) ........... 6> CITY STATE ZIP (25 char) .... 7> PHONE (25 char) ............. 8> CALIF LIC NUMBER (25 char) .. REMARKS ................... BOB EASTON AIA .................... BOB EASTON AIA ARCHITECT ................... 1486.EAST VALLEY ROAD ................... MONTECITO CA 93108 ................... 805-969-5051 ................... #> NUMBER OF REMARKS (50 maximum) .................. 26 SPECIAL FEATURE NOTES 1 1> FAU1/AC1 (MAIN LIVING AREA): BRYANT 350MAV0060100, GAS CONDENSING 2> 100,000 BTUH INPUT, 94,000 BTUH OUTPUT, 94% AFUE, WITH 598BNO60 3> OUTDOOR CONDENSER, 60,000 BTUH OUTPUT 15 SEER, OR EQUAL. 4> 5> FAU2/AC2 (BEDRMS 2&3): BRYANT 350MAV036040, GAS CONDENSING, 6> 40,000 BTUH INPUT, 38,000 BTUH OUTPUT, 95% AFUE, WITH 598BNO36 7> OUTDOOR CONDENSER, 36,000 BTUH OUTPUT, 15 SEER, OR EQUAL. 8> 9> FAU3/AC3 (MASTER BEDRM): BRYANT 350MAV036040, GAS CONDENSING, 10> 40,000 BTUH INPUT, 38,000 BTUH OUTPUT, 95% AFUE, WITH 598BNO36 11> OUTDOOR CONDENSER, 36,000 BTUH OUTPUT, 15 SEER, OR EQUAL. 12> 13> FAU4/AC4 (2ND FLOOR): BRYANT 350MAV036040, GAS CONDENSING, 14> 40,000 BTUH INPUT, 38,000 BTUH OUTPUT, 95% AFUE, WITH 598BNO36 15> OUTDOOR CONDENSER, 36,000 BTUH OUTPUT, 15 SEER, OR EQUAL. 16> 17> AHU-5 (WINE ROOM): MITSUBISHI MSY/MVY-A15NA, SPLIT SYSTEM, 18> DUCTLESS, COOLING ONLY, 15,000 BTUH OUTPUT 15 SEER, OR EQUAL. 19> 20> ALL HVAC DUCTS TO BE INSULATED WITH R-8 DUCT INSULATION. 21> 22> WATER HEATER: AMERICAN POLARIS PGC3-100-199, 100 -GAL., 23> CONDENSING GAS, 95% RECOVERY EFFICENCY, OR EQUAL. 24> 25> HOT WATER RECIRCULATION LOOP WITH TIME/TEMP CONTROLS. FORMATTED INPUT FORMAT Page 7 MICROPAS7 v7.30 File-ROBINSON Wth-CTZ15S05 Program -FORMAT Run -COMPLIANCE Project-ROBINSON/SMALL RESIDENCE Date -11/06/07 26> ALL HOT WATER LINES INSULATED WITH R-4 PIPE INSULATION. Certificate of Occupancyy 4 ti i >U�Wat OF-r9� Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 80-240 VIA PESSARO f Use classification: SINGLE FAMILY DWELLING Building Permit No.: 07-2336 i Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL J I 1 1 Owner of Building: BERT & GENEVIEVE ROBINSON Address: P.O. BOX 1721 City, ST, ZIP: LA QUINTA, CA 92247 } By: STEVE TRAXEL Date: NOVEMBER 19, 2008 ' Building Official POST IN A CONSPICUOUS PLACE